Text

P!*rt Dominion a# Energy' ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT VIRGIL C. SUMMER NUCLEAR STATION FOR THE OPERA TING PERIOD JANUARY 1, 2019 - DECEMBER 31, 2019 Prepared by:

Michelle Westbury, Specialis Health Physics Reviewed by:

I?! a--

Casey Carlson, Supervisor Health Physics

~~roved by:,

0, /_

Xt:JV~ c>V, 17eozo Todd Ellison, Manager Health Physics and Chemistry

Introduction ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2019 VIRGIL C. SUMMER NUCLEAR STATION This report is being submitted as a summary of quantities of radioactive liquid and gaseous effluents and solid waste released from the Virgil C. Summer Nuclear Station. This report is submitted in fulfillment of the requirements in the V. C. Summer Nuclear Station Operating License Technical Specifications Section 6.9.1.8, Offsite Dose Calculation Manual (ODCM) Section1.6.2 and 1 OCFR50.36(a) and follows the reporting details specified in USN RC Regulatory Guide 1.21 (1l.

Summary information of radioactive gaseous and liquid effluents is presented along with a summary of radioactive waste disposal as well as an evaluation of the radiological impact on man due to operation of the Virgil C. Summer Nuclear Station. Supplemental information including release limits also required by USN RC Regulatory Guide 1.21 is provided as Appendix A.

A.

Supplemental Information Regulatory limits for doses, dose rate and effluent concentration limits presented in Supplemental Information are from the Virgil C. Summer Nuclear Station ODCM and 40 CFR 190. Average energy ( E ) is not applicable to the method for determining release rate limits for fission and activation gaseous effluents, therefore, it has been omitted. A compilation of required supplemental information is provided in Appendix A.

B.

Gaseous Effluents Gaseous effluents released from ground level are summarized in Tables 1 and 2. An elevated release pathway does not exist at Virgil C. Summer Nuclear Station. Cumulative doses are discussed in Section E.

The error for both liquid and gaseous release totals is estimated as twenty percent for radioactive radionuclides sampled and released in effluent pathways. Error was derived using root sum of squares methodology considering known sources of error including calibration of detectors and flow measurement equipment, sample preparation, and analysis counting error.

C.

Liquid Effluents Liquid effluents are summarized in Tables 3 and 4. Estimated total errors are expressed as in Section B above.

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2019 VIRGIL C. SUMMER NUCLEAR STATION D.

Solid Waste Shipments Solid waste shipments are summarized in Table 5. Curie content of radioactive waste packages is determined by dose rates and/or gamma spectroscopy analysis of samples.

The total error for each type of curie content determination is conservatively estimated to be the sum of a 15% systematic error and a 20% photon response error for the detector used.

E.

Radiological Impact on Man Dose to the maximum exposed individual in the unrestricted area was calculated using measured plant gaseous effluents and meteorological data in accordance with the Offsite Dose Calculation Manual. The source term involved no Waste Gas Decay Tank (WGDT) releases, 2.79 days of 6-inch Reactor Building purge releases, 5.97 days of 36-inch Reactor Building purge releases and a continuous 12-month Main Plant vent release.

Doses are summarized in Table 6. The total gaseous activities released are presented in Tables 1 and 2. The highest quarterly air doses at the station boundary resulting from the release of noble gases were 7.78E-03 mrad for gamma during the fourth quarter and 2.85E-03 mrad for beta during the fourth quarter. The maximum quarterly organ dose attributed to the releases, excluding Carbon-14, was 1.34E-02 mrem. Cumulative annual dose was 9.02E-03 mrad, 3.30E-03 mrad and 1.87E-02 mrem for gamma, beta, and organ dose, respectively. Discussion of the impact of Carbon-14 is included in Section K.

Measured plant liquid effluent data was used to calculate estimates of doses to individuals in accordance with the Offsite Dose Calculation Manual. The source term consisted of the isotopic contents of 164 Waste Monitor Tank batch releases, 9 Condensate Backwash Receiver Tank batch releases, 1 NaOH Sump batch release, 2.25 days of Steam Generator Slowdown release and a continuous Turbine Building Sump release.

Doses are summarized in Table 6 and total liquid radioactivity released is described in Tables 3 and 4. The highest quarterly total body dose to the maximum exposed individual resulting from the release of radioactive liquid was 7.41 E-03 mrem during the fourth quarter. The highest organ dose was 7.50E-03 mrem to the GI-LU for the fourth quarter.

Cumulative annual doses for the hypothetical maximum exposed individual were 9.33E-03 mrem for the total body and 9.43E-3 mrem for the GI-LU, the maximum annual organ. The GI-LU was maximum exposed organ for all four quarters.

Dose rates and concentrations were below station limits as specified in Supplemental Information,Section II A, B, and C during all the effluent releases.

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2019 VIRGIL C. SUMMER NUCLEAR STATION Radiation exposure to members of the public within the site boundary was assessed through calculation of gamma and beta air dose at 0.25 miles of the gaseous effluent release point and direct measurement of exposure using thermoluminescent dosimeters.

Onsite air dose for this reporting period was 2.94E-02 mrad gamma and 1.07E-02 mrad beta, well below levels that can be distinguished above background. Quarterly thermoluminescent dosimetry (TLD) data from four onsite monitoring locations within 0.2 miles of the Reactor Building and eight locations at the site boundary were analyzed and compared with respective pre-operational background and previous year history. Results showed that the 2019 quarterly dose rates did not differ significantly from the pre-operational or 2018 dose rates.

The impact of Independent Spent Fuel Storage Installation (ISFSI) operation which began cask storage on March 26, 2016 was assessed using six TLD locations monitoring the perimeter of the ISFSI site. The TLD locations were monitored for three quarters prior to fuel storage and continued to be monitored through 2019 during which fuel storage casks were stored. Analysis of monitoring results showed no statistically significant increase in perimeter dose as a result of ISFSI operation.

Based on review of gaseous effluent dose calculations and analysis of onsite TLD monitoring it was concluded that doses to members of the public inside the site boundary were indistinguishable from normal background dose.

Radiation doses from radioactive effluents to workers at the Fairfield Hydro Station for this reporting period were calculated to be 4.27E-04 and 1.56E-04 mrad for gamma and beta, respectively.

Radiation doses from radioactive effluents to workers at the New Nuclear Site for this reporting period were calculated to be 3.67E-03 and 1.34E-03 mrad for gamma and beta, respectively.

Radiation doses from nearby uranium fuel cycle sources were not assessed. The ODCM, Sections 1.3.1 and 8/1.3 establish a five (5) mile limit beyond which doses from nearby plants are insignificant. There are no uranium fuel cycle plants within a five (5) mile radius of Virgil C. Summer Nuclear Station.

F.

Abnormal Releases None

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2019 VIRGIL C. SUMMER NUCLEAR STATION G.

Meteorology The meteorological data for 2019 was collected and analyzed. An annual meteorological summary report of joint frequency distributions of wind direction and speed by atmospheric stability class for each quarter is included as Enclosure A.

The wind direction and wind speed data used were acquired from the 10-meter level of the primary monitoring tower. Stability was determined by the primary differential temperature (61 to 1 O meter).

The combined annual data recovery for wind direction, wind speed and stability was 99.94%. Primary variable recovery rates were as follows: wind direction (10 m) - 99.98%, wind speed (10 m) - 99.98%, and differential temperature (61 - 10 m) - 99.92%.

H.

Offsite Dose Calculation Manual The Virgil C. Summer Nuclear Station ODCM was revised on June 11, 2019. See Enclosure B for a complete copy. The LLD formula was adjusted by dividing the Poisson distribution correction factor (2.71) by count time to align the ODCM with gamma spectroscopy software. The reference to Technical Specification 6.5 was removed because it no longer exists. A note was added to Table 4.0-1 "Radiological Environmental Monitoring Program" to clarify sample frequency requirements to be consistent with intent of NUREG 1301.The location for Radiological Environmental Monitoring Program drinking water location 28 was changed to the Jenkinsville Post Office from the NND building that no longer has water service.

I.

Offsite Dose Calculation Manual Reportable Incidents The Turbine Building Sump Effluent Line Radiation Monitor RM-LB required by ODCM Control 1.1.1.1 was out of service from December 7, 2018 at 1100 until January 24, 2020 at 1420. Out of service condition was the result of a failed detector. Restoration and troubleshooting efforts using a spare detector and preamp by station maintenance personnel and the original equipment manufacturer were not successful. System was restored after procurement of a new detector and preamp following a significant vendor lead time. Compensatory actions were implemented during this time period in accordance with the requirements of the ODCM.

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2019 VIRGIL C. SUMMER NUCLEAR STATION J.

Major Changes to Radioactive Waste Treatment Systems During 2019, there were no major changes to the Radioactive Waste Treatment System.

K.

Carbon-14 Gaseous Effluents Carbon-14 production and release estimates were calculated using EPRI Report 1021106<2>, "Estimation of Carbon-14 in Nuclear Plant Gaseous Effluents". This calculation uses active core coolant mass, average neutron flux by energy and reactor coolant nitrogen concentrations to determine Carbon-14 generation based upon an effective full power year. The estimated generation for VC Summer Nuclear station for 2019 was 9.70 curies.

Public dose estimates were performed using Regulatory Guide 1.109 <3>

methodology. Carbon dioxide is assumed to make up 20% of the Carbon-14 gaseous emissions from the station based upon available references and on-site testing. Carbon-14 is the highest dose contributor of all radionuclides released in gaseous effluents. Annual dose resulting from Carbon-14 releases in gaseous effluents is estimated to be 1.72E-01 mrem total body and 8.62E-01 mrem to the maximum organ (bone).

References

1.

Regulatory Guide 1.21, "Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents From Light Water Cooled Nuclear Power Plants", Revision 1,US Nuclear Regulatory Commission, Washington D.C., 1974.

2. EPRI Report 1021106, "Estimation of Carbon-14 in Nuclear Power Plant Gaseous Effluents",

Electric Power Research Institute, Palo Alto, CA, 2010.

3. Regulatory Guide 1.109, "Calculation of Annual Doses to Man from Routine Releases of

'Reactor effluents for the Purpose of Demonstrating compliance with 10 CFR50, Appendix f',

US Nuclear Regulatory Commission, Washington D.C., 1976.

l

APPENDIX A ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2019 VIRGIL C. SUMMER NUCLEAR STATION SUPPLEMENTAL INFORMATION I.

Regulatory Dose Limits:

A. Fission and Activation Gases:

The air dose to an individual due to noble gases released in gaseous effluents shall be limited to less than or equal to 5 mrad for gamma radiation and 10 mrad for beta radiation during any calendar quarter and 1 O mrad for gamma radiation and 20 mrad for beta radiation during any calendar year (ODCM, Section 1.2.3.1).

B. Iodines, Particulates (half-lives > 8 days) and Tritium:

The dose to an individual from radioiodine, tritium and radioactive materials in particulate form with half-lives greater than 8 days in gaseous effluents shall be limited to less than or equal to 7.5 mrem to any organ during any calendar quarter and 15 mrem to any organ during any calendar year (ODCM, Section 1.2.4.1 ).

C. Liquid Effluents:

The dose or dose commitment to an individual from radioactive materials in liquid effluents released shall be limited to less than or equal to 1.5 mrem to the total body and 5 mrem to any organ during any calendar quarter and 3 mrem to the total body and 10 mrem to any organ during any calendar year (ODCM, Section 1.1.3.1 ).

D. All Sources:

The annual dose equivalent shall not exceed 25 mrem to the whole body, 75 mrem to the thyroid and 25 mrem to any other organ (40 CFR 190).

II.

Dose Rate and Effluent Concentration Limits:

A. Fission and Activation Gases The dose rate in unrestricted areas due to radioactive materials released in gaseous effluents shall be limited to less than or equal to 500 mrem/year to the total body and less than or equal to 3000 mrem/year to the skin (ODCM, Section 1.2.2.1).

APPENDIX A ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2019 VIRGIL C. SUMMER NUCLEAR STATION B. Iodines, Particulates (half-lives > 8 days) and Tritium:

The dose rate in unrestricted areas due to radioactive materials in effluents shall be limited to less than or equal to 1500 mrem/year to any organ (ODCM, Section 1.2.2.1 ).

C. Liquid Effluents:

The concentration of radioactive materials released from the site shall be limited to 10 times the concentrations specified in 10 CFR 20, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 2E-04 µCi/ml total activity (ODCM, Section 1.1.2.1).

Ill.

Average Energy:

Not Applicable IV.

Measurements and Approximations of Total Radioactivity:

A. Fission and activation gases: Gamma spectrometry (HPGe)

B. Iodines: Gamma spectrometry (HPGe)

C.

Particulates: Gamma spectrometry (HPGe), beta proportional counting, alpha proportional counting D. Tritium: Liquid scintillation E. Liquid effluents:

Gamma spectrometry (HPGe), liquid scintillation (H-3), beta proportional counting, alpha proportional counting.

APPENDIX A ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2019 VIRGIL C. SUMMER NUCLEAR STATION V.

Batch Releases:

A.

Gaseous:

1.

Number of batch releases: 0

2.

Total time period for batch releases: 0 min

3.

Maximum time period for a batch release: 0 min

4.

Average time period for a batch release: O min

5.

Minimum time period for a batch release: 0 min B.

Liquid:

1.

Number of batch releases:

38 For first quarter, 2019 27 For second quarter, 2019 28 For third quarter, 2019 81 For fourth quarter, 2019

2.

Total time period for batch releases:

2. 70E+03 min. for first quarter, 2019 1.90E+03 min. for second quarter, 2019 2.02E+03 min. for third quarter, 2019 5.37E+03 min. for fourth quarter 2019
3.

Maximum time period for a batch release:

8.00E+01 min. for second quarter, 2019 9.20E+01 min. for second quarter, 2019 7.70E+01 min. for third quarter, 2019 1.56E+02 min. for fourth quarter, 2019 l

APPENDIX A ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2019 VIRGIL C. SUMMER NUCLEAR STATION

4.

Average time period for batch releases:

7.11E+01 7.03E+01 7.20E+01 6.63E+01 min. for first quarter, 2019 min. for second quarter, 2019 min. for third quarter, 2019 min. for fourth quarter, 2019

5.

Minimum time period for a batch release:

6.70E+01 min. for first quarter, 2019 1.00E+OO min. for second quarter, 2019 6.80E+01 min. for third quarter, 2019 1.00E+OO min. for fourth quarter, 2019

6.

Average stream flow during periods of release of effluent into a flowing stream:

4.30E+06 5.68E+06 7.57E+06 4.10E+06 gpm for first quarter, 2019 gpm for second.quarter, 2019 gpm for third quarter, 2019 gpm for fourth quarter, 2019 VI.

Abnormal Releases:

A.

Gaseous:

1.

Number of releases: 0

2.

Total activity released: O B.

Liquid:

1.

Number of releases: 0

2.

Total activity released: O

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2019 Virgil C. Summer Nuclear Station TABLE 1 Gaseous Effluents-Summation of All Releases Type of Effluent A. Fission & Activation Gases

1. Total Release
2. Average Release Rate for Period
3. Percent of Applicable Limit B. Iodines
1. Total lodine-131
2. Average Release Rate for Period
3. Percent of Applicable Limit C. Particulates
1. Total Particulates (Half-lives > 8 days)
2. Average Release Rate for Period
3. Percent of Applicable Limit
4. Gross Alpha Activity D. Tritium
1. Total Release
2. Average Release Rate for Period
3. Percent of Applicable Limit E. Carbon-14
1. Total Release
2. Average Release Rate for Period Units Curies

µCi/sec Curies

µCi/sec Curies

µCi/sec Curies Curies

µCi/sec Curies

µCi/sec Qtr1 Qtr2 Qtr3 Qtr4 O.OOE+OO O.OOE+OO 7.03E-01 4.57E+OO O.OOE+OO O.OOE+OO 8.85E-02 5.75E-01 O.OOE+OO O.OOE+OO 2.49E-02 1.56E-01 O.OOE+OO O.OOE+OO O.OOE+OO 5.36E-07 6.89E-08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 6.0SE-06 7.73E-07 O.OOE+OO O.OOE+OO 3.10E+OO 3.94E-01 2.35E-02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.35E+01 2.96E+OO 1.79E-01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 6.19E+OO 7.79E-01 4.70E-02 2.39E+OO 2.42E+OO 2.44E+OO 2.44E+OO 3.0SE-01 3.0SE-01 3.0SE-01 3.0SE-01 Error%

2.00E+01 2.50E+01 2.50E+01 O.OOE+OO 2.00E+01 N/A

Nuclides Released ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2019 Virgil C. Summer Nuclear Station TABLE2 Gaseous Effluents-Ground Level Releases Continuous Mode Batch Mode Units Qtr 1 Qtr2 Qtr3 Qtr4 Qtr 1 Qtr2 Qtr3 Qtr4

1. Fission and Activation Gases Ar-41 Xe-133 Xe-135 Total for Period
2. Iodines Total for Period
3. Particulates Be-7 Br-82 Total for Period
4. Tritium H-3 Curies-O.OOE+OO O.OOE+OO 6.61E-01 4.14E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Curies O.OOE+OO O.OOE+OO O.OOE+OO 2.68E-01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Curies O.OOE+OO O.OOE+OO 4.27E-02 1.60E-01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Curies O.OOE+OO O.OOE+OO 7.03E-01 4.57E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Curies 5.36E-07 6.0BE-06 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Curies 5.36E-07 6.0BE-06 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Curies O.OOE+OO 3.10E+OO 2.35E+01 6.19E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2019 Virgil C. Summer Nuclear Station TABLE3 Liquid Effluents-Summation of All Releases Type of Effluent Units Qtr 1 Qtr2 Qtr3 Qtr4 A. Fission & Activation Products

1.

Total Release (not including Tritium, Curies 9.16E-04 8.76E-05 1.89E-04 1.66E-03 Gases, and Alpha)

2.

Average Diluted Concentration During

µCi/ml 1.96E-11 2.07E-12 3.09E-12 1.93E-11 Period

3.

Percent of Applicable Limit 1.83E-02 1.75E-03 3.79E-03 3.32E-02

8. Tritium
1.

Total Release Curies 3.24E+01 4.59E+01 1.75E+02 5.92E+02

2.

Average Diluted Concentration During

µCi/ml 6.91E-07 1.09E-06 2.SSE-06 6.87E-06 Period

3.

Percent of Applicable Limit 6.91E-02 1.09E-01 2.SSE-01 6.87E-01 C. Dissolved and Entrained Gases

1.

Total Release Curies O.OOE+OO O.OOE+OO O.OOE+OO 5.71E-04

2.

Average Diluted Concentration During

µCi/ml O.OOE+OO O.OOE+OO O.OOE+OO 6.62E-12 Period

3.

Percent of Applicable Limit O.OOE+OO O.OOE+OO O.OOE+OO 3.31E-06 D. Gross Alpha Radioactivity

1.

Total Release Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO E. Waste Volume Released (Pre-Dilution)

Liters 7.28E+06 7.58E+06 8.90E+06 1.48E+07 F. Volume of Dilution Water Used Liters 4.68E+10 4.23E+10 6.12E+10 8.62E+10 Error%

2.00E+01 2.00E+01 2.00E+01 O.OOE+OO 3.00E+OO 4.30E+OO

Nuclides Released Ar-41 As-76 Co-58 Co-60 Cr-51 Cs-137 H-3 Mn-54 Nb-95 Ni-63 Sb-122 Sb-124 Sb-125 Sb-126 Te-123M Te-125m Xe-133 Xe-133m Xe-135 Zn-65 Zr-95 Zr-97 Total for Period ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2019 Virgil C. Summer Nuclear Station TABLE4 Liquid Effluents Continuous Mode Batch Mode Units Qtr 1 Qtr2 Qtr3 Qtr4 Qtr 1 Qtr2 Qtr3 Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.68E-05 5.32E-06 5.62E-07 Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 9.12E-05 1.14E-05 1.39E-04 Curies O.OOE+OO O.OOE+OO O.OOE+OO 0.00E+OO O.OOE+OO O.OOE+OO O.OOE+OO Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.12E-08 O.OOE+OO Curies 3.10E-02 1.50E-02 4.56E-02 3.22E-02 3.23E+01 4.59E+01 1.74E+02 Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 5.99E-06 O.OOE+OO 9.70E-06 Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.83E-04 4.SOE-05 3.18E-05 Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.33E-05 O.OOE+OO O.OOE+OO Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 6.65E-05 2.42E-05 5.BOE-06 Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.47E-05 6.25E-07 O.OOE+OO Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.84E-04 O.OOE+OO O.OOE+OO Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.72E-06 Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Curies O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Qtr4 1.45E-05 2.87E-06 2.75E-04 5.83E-04 3.19E-05 O.OOE+OO 5.92E+02 3.54E-05 2.77E-05 O.OOE+OO 2.51E-06 7.87E-05 8.0SE-05 1.91E-06 O.OOE+OO 5.15E-04 3.96E-04 2.84E-06 1.58E-04 O.OOE+OO 1.17E-05 1.49E-05 Curies 3.10E-02 1.50E-02 4.56E-02 3.22E-02 3.23E+01 4.59E+01 1.74E+02 5.92E+02

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT January - December 2019 Virgil C. Summer Nuclear Station Dominion Energy Table 5 SOLID WASTE SHIPMENTS

1. Solid Waste Shipped Offsite for Burial or Disposal (Not irradiated fuel) 2019 Est. Total Type of Waste Unit Total Error,%
a. Spent resins, filters, sludge, m3 3.40E+01 2.5E+01 evaporator bottoms, etc.

Ci 4.47E+01

b. Dry compressible waste, metals, m3 2.21E+02 2.5E+01 contaminated equipment, etc.

Ci 5.46E-02

c. Irradiated components, m3 O.OOE+OO N/A control rods, etc.

Ci O.OOE+OO

d. Other waste, oil, etc.

m3 O.OOE+OO N/A Ci O.OOE+OO

2. Estimate of major nuclide composition for the year (by type of waste) for concentrations above 1.0%
a.

Ni-63 37.50 %

1.68E+01 Ci Co-60 27.99 %

1.25E+01 Ci Fe-55 19.82, %

8.88E+OO Ci Cr-51 4.60%

2.06E+OO Ci Mn-54 4.39%

1.97E+OO Ci Sb-125 2.97%

1.33E+OO Ci Co-58 1.16 %

5.18E-01 Ci

b.

Fe-55 34.57 %

1.89E-02 Ci Co-60 29.86 %

1.63E-02 Ci Co-58 12.65 %

6.91E-03 Ci Ni-63 11.12 %

6.07E-03 Ci Mn-54 3.90%

2.13E-03 Ci Cr-51 1.98 %

1.08E-03 Ci Nb-95 1.62 %

8.83E-04 Ci Sb-125 1.08 %

5.88E-04 Ci

C.

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT January - December 2019 Virgil C. Summer Nuclear Station Dominion Energy Table 5 SOLID WASTE SHIPMENTS

,-1 -------:-,N=--o-ne-----------,--_____,N,...,,./-,-A---,-----N-/A---~

d.

,-1 _ _ _ _ _ _ N_o_n_e--------r----N-/-A--~---N-/A---~

3. Solid Waste Disposition Number of Shioments Mode of Transoortation Destination 1 -

Cast Transportation UniTech Services Group, Inc.

Oakridge, TN Energy Solutions, LLC 5

Hittman Transport Barnwell Processing Facility/

Barnwell Disposal Facility Barnwell, SC 4

Landstar Alaron - Wampum, PA Notes:

1.

One shipment by Cast Transportation containing (2) 20-foot Sealands of Green is Clean Waste was shipped to Oakridge, TN for processing.

2.

Five shipments by Hittman Transport containing (1)10-160 FR SEDS High Integrity Container of Dewatered Primary Resin; (1) 8-120 FR High Integrity Container of Dewatered Cation/Anion Resin; and (1) 8-120 FR High Integrity Container of Dewatered Mixed Bed Resin; (1) 8-120 FEXM High Integrity Container of Mechanical Filters and Dry Active Waste; and (1) 8-120 FR High Integrity Container of Dewatered Charcoal/Cation/Anion Resin were shipped to the Barnwell Processing and Barnwell Disposal facilities for processing and burial.

3.

Four shipments by Landstar containing (4) 20-foot Sealands of Dry Active Waste; (2) 8-25 Boxes of Gross Dewatered Nuclear Slowdown Resin; (5) 8-25 Box of Gross Dewatered Mixed Bed Resin; (3) 8-25 Boxes of Mopheads/Rags; (2) 8-25 Boxes of Dry Active Waste; (3) 8-12 Boxes of Metal; and (9) 8-25 Boxes of Metal were shipped to Alaron in Wampum, PA for processing.

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2019 Virgil C. Summer Nuclear Station TABLE6 Gaseous Effluents Parameter Location Dose Dose Limit

% of Limit Qtr 1 Gamma Air Dose (mrad) 1.61 km ENE O.OOE+OO 5.00E+OO 0.00 Beta Air Dose (mrad) 1.61 km ENE O.OOE+OO 1.00E+01 0.00 Total Body Dose (mrem) 1.61 km ENE O.OOE+OO 5.00E+OO 0.00 Skin Dose (mrem) 1.61 km ENE O.OOE+OO 7.50E+OO 0.00 Max Organ Dose (mrem)*

1.77 km E O.OOE+OO 7.50E+OO 0.00 None-None Qtr2 Gamma Air Dose (mrad) 1.61 km ENE O.OOE+OO 5.00E+OO 0.00 Beta Air Dose (mrad) 1.61 km ENE O.OOE+OO 1.00E+01 0.00 Total Body Dose (mrem) 1.61 km ENE O.OOE+OO 5.00E+OO 0.00 Skin Dose (mrem) 1.61 km ENE O.OOE+OO 7.50E+OO 0.00 Max Organ Dose (mrem)*

1.77 km E 1.76E-03 7.50E+OO 0.02 Child-Liver Qtr3 Gamma Air Dose (mrad) 1.61 km ENE 1.24E-03 5.00E+OO 0.02 Beta Air Dose (mrad) 1.61 km ENE 4.54E-04 1.00E+01 0.00 Total Body Dose (mrem) 1.61 km ENE 1.18E-03 5.00E+OO 0.02 Skin Dose (mrem) 1.61 km ENE 1.74E-03 7.50E+OO 0.02 Max Organ Dose (mrem)*

1.77 km E 1.34E-02 7.50E+OO 0.18 Child-Liver Qtr4 Gamma Air Dose (mrad) 1.61 km ENE 7.78E-03 5.00E+OO 0.16 Beta Air Dose (mrad) 1.61 km ENE 2.85E-03 1.00E+01 0.03 Total Body Dose (mrem) 1.61 km ENE 7.39E-03 5.00E+OO 0.15 Skin Dose (mrem) 1.61 km ENE 1.09E-02 7.50E+OO 0.14 Max Organ Dose (mrem)*

1.77 km E 3.53E-03 7.50E+OO 0.05 Child - Liver Year Gamma Air Dose (mrad) 1.61 km ENE 9.02E-03 1.00E+01 0.09 Beta Air Dose (mrad) 1.61 km ENE 3.30E-03 2.00E+01 0.02 Total Body Dose (mrem) 1.61 km ENE 8.57E-03 1.00E+01 0.09 Skin Dose (mrem) 1.61 km ENE 1.26E-02 1.50E+01 0.08 Max Organ Dose (mrem)*

1.77 km E 1.87E-02 1.50E+01 0.12 Child-Liver

(* Includes dose from all nuclides excluding Carbon-14. See Section K for C-14)

Liquid Effluents Parameter Max ReceQtor Dose Dose Limit

% of Limit Qtr 1 Max Organ Dose (mrem)

Adult - Gi-Lli 4.08E-04 5.00E+OO 0.01 Total Body Dose (mrem)

Adult - Total Body 4.00E-04 1.50E+OO 0.03 Qtr2 Max Organ Dose (mrem)

Adult - Gi-Lli 3.84E-04 5.00E+OO 0.01 Total Body Dose (mrem)

Adult - Total Body 3.84E-04 1.50E+OO 0.03 Qtr3 Max Organ Dose (mrem)

Adult - Gi-Lli 1.14E-03 5.00E+OO 0.02 Total Body Dose (mrem)

Adult - Total Body 1.14E-03 1.50E+OO 0.08 Qtr4 Max Organ Dose (mrem)

Adult - Gi-Lli 7.50E-03 5.00E+OO 0.15 Total Body Dose (mrem)

Adult - Total Body 7.41E-03 1.50E+OO 0.49 Year Max Organ Dose (mrem)

Adult - Gi-Lli 9.43E-03 1.00E+01 0.09 Total Body Dose (mrem)

Adult-Total Body 9.33E-03 3.00E+OO 0.31 NOTE: See Section E for max organ for each quarter

ENCLOSURE A ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY - DECEMBER 2019 VIRGIL C. SUMMER NUCLEAR STATION METEOROLOGICAL DATA JOINT FREQUENCY DISTRIBUTION BY QUARTER FOR 2019

Annual Summary

Site:

VC Period of Record=

Elevation:

Stability Class:

Wind Direction N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total Speed:

SPlOTl A

0.8-3.9 29 15 8

3 1

0 0

0 0

3 15 30 24 17 13 28 186 Calm Hours not Included above for:

Variable Direction Hours for:

Invalid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

Page 1 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 01/01/2019 01:00 - 01/01/2020 00:00 Direction:

DRIOT1 Lapse:

DT61Tl Delta Temperature 4.0-7.9 8.0-12.9 63 12 54 12 45 32 25 9

13 3

3 0

0 4

4 6

15 15 36 30 126 19 116 20 83 20 52 10 45 9

23 12 703 213 Total Period Total Period Total Period Total Period Extremely Unstable Wind Speed (mph) 13.0-18.9 19.0-23.9 4

6 27 16 11 0

0 0

0 0

0 0

0 0

0 2

0 5

0 0

0 0

0 0

0 0

0 0

53 22 All Hours All Hours All Hours All Hours

>24.0 1

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 Report Printed On: 02/25/2020 09:45 All Hours Total 115 124 96 38 17 3

4 10 32 74 160 166 128 80 67 64 1178 0

0 5

1178 8760

Site:

VC Period of Record=

Elevation:

Stability Class:

Wind Direction N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total Speed:

SPIOT1 B

0.8-3.9 16 14 14 2

2 2

0 1

0 4

13 19 14 6

10 9

126 Calm Hours not Included above for:

Variable Direction Hours for:

Invalid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

Page 2 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 01/01/2019 01:00 - 01/01/2020 00:00 Direction:

DRlOTl Lapse:

DT61Tl Delta Temperature 4.0-7.9 8.0-12.9 31 21 31 46 31 61 18 26 17 4

9 7

4 11 7

13 24 13 35 15 58 11 36 8

17 6

8 1

14 6

12 4

352 253 Total Period Total Period Total Period Total Period Moderately Unstable Wind Speed (mph) 13.0-18.9 19.0-23.9 12 7

52 13 51 0

4 0

0 0

0 0

0 0

0 0

2 0

3 0

0 0

0 0

1 0

0 0

0 0

0 126 20 All Hours All Hours All Hours All Hours

>24.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

Report Printed On: 02/25/2020 09:45 All Hours Total 87 156 157 50 23 18 15 21 39 57 82 63 38 15 31 25 877 0

0 5

877 8760

Site:

VC Period of Record=

Elevation:

Stability Class:

Wind Direction N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total Speed:

SPlOTl C

0.8-3.9 10 19 12 3

0 1

3 5

8 6

18 10 12 13 13 14 147 Calm Hours not Included above for:

Variable Direction Hours for:

Invalid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

Page 3 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 01/01/2019 01:00 - 01/01/2020 00:00 Direction:

DRlOTl Lapse:

DT61Tl Delta Temperature 4.0-7.9 31 35 47 20 27 14 31 42 39 34 24 15 8.0-12.9 9

7 16 16 407 Total Period Total Period Total Period Total Period 22 62 122 87 23 7

9 12 15 15 10 4

0 0

3 17 408 Slightly Unstable Wind Speed (mph) 13.0-18.9 19.0-23.9

>24.0 16 3

3 25 9

0 32 0

0 13 0

0 2

0 0

0 0

0 0

0 0

0 0

0 0

2 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 5

0 0

97 13 3

All Hours All Hours All Hours All Hours Report Printed On: 02/25/2020 09:45 All Hours Total 85 150 213 123 52 22 43 60 63 57 52 29 21 20 33 52 1075 0

0 5

1075 8760

Site:

VC Report Printed On: 02/25/2020 09:45 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record=

01/01/2019 01:00 - 01/01/2020 00:00 Elevation:

Speed:

SPlOTI Direction:

DRlOTl Lapse:

DT61Tl Stability Class:

D Delta Temperature Neutral Wind Speed (mph)

Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 Total N

37 62 31 11 2

144 NNE 31 60 38 17 5

0 151 NE 19 64 75 25 2

2 187 ENE 19 98 101 17 1

237 E

14 123 64 1

0 0

202 ESE 8

80 7

0 0

0 95 SE 30 130 19 0

0 0

179 SSE 46 137 33 2

0 0

218 s

33 114 60 9

0 217 SSW 49 194 52 7

0 0

302 SW 76 119 22 0

0 218 WSW 45 80 21 0

0 0

146 w

51 57 12 0

0 0

120 WNW 58 21 1

0 0

0 80 NW 42 56 11 1

0 0

110 NNW 39 33 29 9

0 111 Total 597 1428 576 100 12 4

2717 Calm Hours not Included above for:

Total Period All Hours 0

Variable Direction Hours for:

Total Period All Hours 0

Invalid Hours for:

Total Period All Hours 5

Number of Valid Hours for this Table:

Total Period All Hours 2717 Total Hours for the Period:

8760 Page 4 of 8

Site:

VC Report Printed On: 02/25/2020 09:45 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record=

01/01/2019 01:00

  • 01/01/2020 00:00 Elevation:

Speed:

SPlOTl Direction:

DRlOTl Lapse:

DT61Tl Stability Class:

E Delta Temperature Slightly Stable Wind Speed (mph)

Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 Total N

21 24 6

1 1

0 53 NNE 27 21 5

0 2

56 NE 10 16 6

0 0

0 32 ENE 11 12 3

0 0

0 26 E

18 39 12 0

0 0

69 ESE 16 21 0

0 0

0 37 SE 20 97 2

0 0

0 119 SSE 64 120 4

0 0

0 188 s

63 92 2

0 1

0 158 SSW 78 124 6

0 0

0 208 SW 140 63 3

0 0

0 206 WSW 91 54 2

0 0

0 147 w

90 58 0

0 0

0 148 WNW 72 16 0

0 0

0 88 NW 44 40 0

0 0

0 84 NNW 18 18 1

2 0

0 39 Total 783 815 52 3

4 1

1658 Calm Hours not Included above for:

Total Period All Hours 0

Variable Direction Hours for:

Total Period All Hours 0

Invalid Hours for:

Total Period All Hours 5

Number of Valid Hours for this Table:

Total Period All Hours 1658 Total Hours for the Period:

8760 Page 5 of8

Site:

vc Report Printed On: 02/25/2020 09:45 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record=

01/01/2019 01:00

  • 01/01/2020 00:00 Elevation:

Speed:

SPlOTl Direction:

DRlOTl Lapse:

DT61Tl Stability Class:

F Delta Temperature Moderately Stable Wind Speed (mph)

Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 Total N

8 3

0 0

0 0

11 NNE 6

3 0

0 0

0 9

NE 6

3 0

0 0

0 9

ENE 3

0 0

0 0

0 3

E 6

0 0

0 0

7 ESE 7

0 0

0 0

0 7

SE 13 21 0

0 0

0 34 SSE 23 53 0

0 0

0 76 s

44 57 0

0 0

0 101 SSW 57 34 0

0 0

92 SW 98 13 0

1 0

0 112 WSW 67 8

0 0

0 0

75 w

64 20 0

0 0

0 84 WNW 52 3

0 0

0 0

55 NW 26 3

0 0

0 0

29 NNW 9

7 0

0 0

0 16 Total 489 229 1

1 0

0 720 Calm Honrs not Included above for:

Total Period All Hours 0

Variable Direction Hours for:

Total Period All Hours 0

Invalid Hours for:

Total Period All Hours 5

Number of Valid Hours for this Table:

Total Period All Hours 720 Total Hours for the Period:

8760 Page 6 of 8

Site:

VC Report Printed On: 02/25/2020 09:45 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record=

01/01/2019 01:00 - 01/01/2020 00:00 Elevation:

Speed:

SPlOTl Direction:

DRlOTl Lapse:

DT61Tl Stability Class:

G Delta Temperature Extremely Stable Wind Speed (mph)

Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 Total N

3 0

0 0

0 0

3 NNE 3

0 0

0 0

0 3

NE 0

0 0

0 0

0 0

ENE 0

0 0

0 0

E 0

0 0

0 0

ESE 3

0 0

0 0

0 3

SE 3

2 0

0 0

0 5

SSE 21 20 0

0 0

0 41 s

44 8

0 0

0 0

52 SSW 48 10 0

0 0

0 58 SW 101 9

0 0

0 0

110 WSW 115 6

0 0

0 0

121 w

71 3

0 0

0 0

74 WNW 33 0

0 0

0 0

33 NW 16 1

0 0

0 0

17 NNW 7

1 0

0 0

0 8

Total 470 60 0

0 0

0 530 Calm Hours not Included above for:

Total Period All Hours 0

Variable Direction Hours for:

Total Period All Hours 0

Invalid Hours for:

Total Period All Hours 5

Number of Valid Hours for this Table:

Total Period All Hours 530 Total Hours for the Period:

8760 Page 7 of 8

Site:

vc Report Printed On: 02/25/2020 09:45 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record=

01/01/2019 01:00

  • 01/01/2020 00:00 Elevation:

Speed:

SPlOTl Direction:

DRIOT1 Lapse:

DT61Tl Stability Class:

ALL Delta Temperature Wind Speed (mph)

Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 Total N

124 214 92 44 19 5

498 NNE 115 204 163 121 45 649 NE 69 206 296 119 2

2 694 ENE 42 173 226 35 1

1 478 E

42 220 106 3

0 0

371 ESE 37 127 21 0

0 0

185 SE 69 285 45 0

0 0

399 SSE 160 383 68 3

0 0

614 s

192 349 105 14 2

0 662 SSW 245 467 119 17 0

0 848 SW 461 412 65 2

0 0

940 WSW 377 315 55 0

0 0

747 w

326 247 38 2

0 0

613 WNW 251 107 12 0

0 371 NW 164 175 29 2

1 0

371 NNW 124 110 63 17 0

315 Total 2798 3994 1503 380 71 9

8755 Calm Hours not Included above for:

Total Period All Hours 0

Variable Direction Hours for:

Total Period All Hours 0

Invalid Hours for:

Total Period All Hours 5

Number of Valid Hours for this Table:

Total Period All Hours 8755 Total Hours for the Period:

8760 Page 8 of 8

Quarterly Summaries

Site:

VC Period of Record =

Elevation:

Stability Class:

Wind Direction N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total Speed:

SPlOTl A

0.8-3.9 2

0 0

0 0

0 0

0 0

0 0

0 3

0 7

13 Calm Hours not Included above for:

Variable Direction Hours for:

Invalid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

Page 1 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 01/01/2019 01:00 - 04/01/2019 00:00 Direction:

DRlOTl Lapse:

DT61Tl Delta Temperature 4.0-7.9 8.0-12.9 4

1 0

3 2

4 0

0 0

0 0

0 0

0 0

3 3

9 14 2

10 5

24 12 10 2

7 4

3 3

78 49 Total Period Total Period Total Period Total Period Extremely Unstable Wind Speed (mph) 13.0-18.9 19.0-23.9 1

0 10 0

4 0

0 0

0 0

0 0

0 0

0 2

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 18 0

All Hours All Hours All Hours All Hours

>24.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

Report Printed On: 02/25/2020 09:46 All Hours Total 8

13 10 3

0 0

0 0

5 12 16 15 39 13 11 13 158 0

0 0

158 2160

Site:

VC Period of Record=

Elevation:

Stability Class:

Wind Direction N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total Speed:

SPIOTI B

0.8-3.9 5

2 3

0 0

0 0

0 0

0 0

2 0

2 1

0 15 Calm Hours not Included above for:

Variable Direction Hours for:

Invalid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

Page 2 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 01/01/2019 01:00- 04/01/2019 00:00 Direction:

DRIOTI Lapse:

DT61Tl Delta Temperature 4.0-7.9 9

9 4

2 3

0 0

0 0

5 8.0-12.9 14 6

4 2

5 2

65 Total Period Total Period Total Period Total Period 7

7 16 6

0 0

0 0

2 2

3 2

5 1

2 1

54 Moderately Unstable Wind Speed (mph) 13.0-18.9 19.0-23.9

>24.0 7

0 0

3 0

13 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 26 0

All Hours All Hours All Hours All Hours Report Printed On: 02/25/2020 09:46 All Hours Total 28 22 36 9

3 0

0 0

2 7

17 10 10 5

9 3

161 0

0 0

161 2160

Site:

VC Period of Record=

Elevation:

Stability Class:

Wind Direction N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total Speed:

SPlOTI C

0.8-3.9 3

5 3

0 0

0 0

1 3

0 5

2 6

5 35 Calm Hours not Included above for:

Variable Direction Hours for:

Invalid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

Page 3 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 01/01/2019 01:00 - 04/01/2019 00:00 Direction:

DRlOTI Lapse:

DT61Tl Delta Temperature 4.0-7.9 11 14 16 8.0-12.9 4

3 2

6 4

6 5

5 7

2 2

14 8

109 Total Period Total Period Total Period Total Period 7

14 38 41 6

0 1

3 2

6 3

2 0

0 3

7 133 Slightly Unstable Wind Speed (mph) 13.0-18.9 19.0-23.9

>24.0 3

0 7

2 0

17 0

0 6

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0, 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2 0

0 36 3

0 All Hours All Hours All Hours All Hours Report Printed On: 02/25/2020 09:46 All Hours Total 25 42 74 51 9

2 7

9 11 11 9

10 7

4 23 22 316 0

0 0

316 2160

Site:

VC Report Printed On: 02/25/2020 09:46 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record=

01/01/2019 01:00 - 04/01/2019 00:00 Elevation:

Speed:

SPIOTI Direction:

DRIOTI Lapse:

DT61TI Stability Class:

D Delta Temperature Neutral Wind Speed (mph)

Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 Total N

10 24 11 7

0 0

52 NNE 9

12 9

1 0

0 31 NE 11 21 20 3

0 0

55 ENE 5

31 34 3

0 0

73 E

4 30 19 1

0 0

54 ESE 3

22 2

0 0

0 27 SE 9

22 2

0 0

0 33 SSE 15 26 7

2 0

0 50 s

10 19 18 6

0 0

53 SSW 14 36 20 0

0 0

70 SW 13 27 6

0 0

0 46 WSW 12 26 12 0

0 0

50 w

18 21 8

0 0

0 47 WNW 21 7

0 0

0 0

28 NW 12 27 6

0 0

46 NNW 14 12 16 3

0 0

45 Total 180 363 190 27 0

0 760 Calm Hours not lnclnded above for:

Total Period All Hours 0

Variable Direction Hours for:

Total Period All Hours 0

Invalid Hours for:

Total Period All Hours 0

Number of Valid Hours for this Table:

Total Period All Hours 760 Total Hours for the Period:

2160 Page4 of 8

Site:

VC Period of Record=

Elevation:

Stability Class:

Wind Direction N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total Speed:

SPlOTl E

0.8-3.9 6

10 4

2 5

1 3

13 15 16 31 21 23 27 9

9 195 Calm Hours not Included above for:

Variable Direction Hours for:

Invalid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

Page 5 of8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 01/01/2019 01:00 - 04/01/2019 00:00 Direction:

DRlOTl Lapse:

DT61Tl Delta Temperature 4.0-7.9 8.0-12.9 17 6

8 4

11 8

27 15 22 27 17 7

24 10 13 6

222 Total Period Total Period Total Period Total Period 0

0 1

0 2

0 1

3 1

4 0

0 0

0 0

0 12 Slightly Stable Wind Speed (mph) 13.0-18.9 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

2 2

19.0-23.9 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

All Hours All Hours All Hours All Hours

>24.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

Report Printed On: 02/25/2020 09:46 All Hours Total 23 16 13 6

18 9

31 31 38 47 48 28 47 37 22 17 431 0

0 0

431 2160

Site:

VC Report Printed On: 02/25/2020 09:46 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record=

01/01/2019 01:00 - 04/01/2019 00:00 Elevation:

Speed:

SPlOTl Direction:

DRlOTl Lapse:

DT61Tl Stability Class:

F Delta Temperature Moderately Stable Wind Speed (mph)

Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 Total N

5 0

0 0

0 6

NNE 2

0 0

0 0

3 NE 5

0 0

0 0

6 ENE 0

0 0

0 o,

E 2

1 0

0 0

0 3

ESE 1

0 0

0 0

0 1

SE 5

9 0

0 0

0 14 SSE 3

13 0

0 0

0 16 s

5 16 0

0 0

0 21 SSW 12 9

0 0

0 0

21 SW 29 3

0 0

0 0

32 WSW 15 3

0 0

0 0

18 w

14 8

0 0

0 0

22 WNW 9

2 0

0 0

0 11 NW 9

0 0

0 0

10 NNW 4

2 0

0 0

0 6

Total 121 70 0

0 0

0 191 Calm Hours not Included above for:

Total Period All Hours 0

Variable Direction Hours for:

Total Period All Hours 0

Invalid Hours for:

Total Period All Hours 0

Number of Valid Hours for this Table:

Total Period All Hours 191 Total Hours for the Period:

2160 Page 6 of 8

Site:

VC Report Printed On: 02/25/2020 09:46 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record=

01/01/2019 01:00 - 04/01/2019 00:00 Elevation:

Speed:

SPlOTl Direction:

DRlOTl Lapse:

DT61Tl Stability Class:

G Delta Temperature Extremely Stable Wind Speed (mph)

Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 Total N

3 0

0 0

0 0

3 NNE 0

0 0

0 0

0 0

NE 0

0 0

0 0

0 0

ENE 0

0 0

0 0

0 0

E 1

0 0

0 0

0 ESE 2

0 0

0 0

0 2

SE 1

0 0

0 0

2 SSE 11 7

0 0

0 0

18 s

13 3

0 0

0 0

16 SSW 12 4

0 0

0 0

16 SW 12 5

0 0

0 0

17 WSW 18 0

0 0

0 0

18 w

18 2

0 0

0 0

20 WNW 17 0

0 0

0 0

17 NW 9

0 0

0 0

0 9

NNW 4

0 0

0 0

0 4

Total 121 22 0

0 0

0 143 Calm Hours not Included above for:

Total Period All Hours 0

Variable Direction Hours for:

Total Period All Hours 0

Invalid Hours for:

Total Period All Hours 0

Number of Valid Hours for this Table:

Total Period All Hours 143 Total Hours for the Period:

2160 Page 7 of 8

Site:

VC Period of Record=

Elevation:

Stability Class:

Wind Direction N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total Speed:

SPlOTl ALL 0.8-3.9 34 28 26 8

12 7

18 43 46 54 86 69 81 79 46 43 680 Calm Hours not Included above for:

Variable Direction Hours for:

In~alid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

Page 8 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 01/01/2019 01:00 - 04/01/2019 00:00 Direction:

DRlOTl Lapse:

DT61Tl Delta Temperature Wind Speed (mph) 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 66 26 18 1

0 42 33 21 3

0 52 79 37 0

0 42 82 11 0

0 48 27 0

0 32 2

0 0

0 65 4

0 0

0 65 13 3

0 0

66 26 8

0 0

89 41 0

0 0

85 14 0

0 0

59 21 0

0 0

85 25 1

0 0

33 3

0 0

0 67 15 2

0 0

33 27 7

0 0

929 438 109 4

0 Total Period All Hours Total Period All Hours Total Period All Hours Total Period All Hours Report Printed On: 02/25/2020 09:46 All Hours Total 145 127 194 143 88 41 87 124 146 184 185 149 192 115 130 110 2160 0

0 0

2160 2160

Site:

VC Period of Record=

Elevation:

Speed:

SPIOTI Stability Class:

A Wind Direction 0.8-3.9 N

5 NNE 4

NE 4

ENE 2

E 0

ESE 0

SE 0

SSE 0

s 0

SSW SW 4

WSW 4

w 7

WNW 2

NW 6

NNW 5

Total 44 Calm Hours not Included above for:

Variable Direction Hours for:

Invalid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

Page 1 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 04/01/2019 01:00 - 07/01/2019 00:00 Direction:

DRIOTI Lapse:

DT61Tl Delta Temperature 4.0-7.9 8.0-12.9 27 17 12 12 9

3 0

7 15 54 43 28 24 20 5

277 Total Period Total Period Total Period Total Period 8

4 11 0

4 4

8 16 9

II 7

5 3

93 Extremely Unstable Wind Speed (mph) 13.0-18.9 2

3 0

0 0

0 0

0 2

0 0

0 II 19.0-23.9 I

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 All Hours All Hours All Hours All Hours

>24.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

Report Printed On: 02/25/2020 09:47 All Hours Total 42 27 30 15 IO 3

4 5

15 34 67 58 43 32 27 14 426 0

0 0

426 2184

Site:

VC Report Printed On: 02/25/2020 09:47 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record=

04/01/2019 01:00 - 07/01/2019 00:00 Elevation:

Speed:

SPlOTl Direction:

DRlOTl Lapse:

DT61Tl Stability Class:

8 Delta Temperature Moderately Unstable Wind Speed (mph)

Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 Total N

2 7

3 0

0 0

12 NNE 3

6 3

6 0

19 NE 3

3 4

4 0

0 14 ENE 0

2 2

1 0

0 5

E 3

2 0

0 0

6 ESE 0

6 1

0 0

0 7

SE 0

3 8

0 0

0 11 SSE 0

2 8

0 0

0 10 s

0 11 6

2 0

0 19 SSW 2

21 6

0 0

0 29 SW 4

22 4

0 0

0 30 WSW 5

11 3

0 0

0 19 w

3 6

0 0

0 10 WNW 3

3 0

0 0

0 6

NW 4

3 0

0 0

0 7

NNW 3

2 2

0 0

0 7

Total 33 111 53 13 0

211 Calm Hours not Included above for:

Total Period All Hours 0

Variable Direction Hours for:

Total Period All Hours 0

Invalid Hours for:

Total Period All Hours 0

Number of Valid Hours for this Table:

Total Period All Hours 211 Total Hours for the Period:

2184 Page 2 of 8

Site:

VC Period of Record=

Elevation:

Stability Class:

Wind Direction N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total Speed:

SPlOTl C

0.8-3.9 0

2 1

0 0

0 0

2 1

1 4

2 2

5 1

3 24 Calm Hours not Included above for:

Variable Direction Hours for:

Invalid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

Page 3 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 04/01/2019 01:00 - 07/01/2019 00:00 Direction:

DRlOTl Lapse:

DT61Tl Delta Temperature 4.0-7.9 3

1 4

8.0-12.9 3

3 10 28 22 21 10 5

3 3

0 3

120 Total Period Total Period Total Period Total Period 4

1 2

7 2

1 6

7 12 4

5 0

0 0

0 1

52 Slightly Unstable Wind Speed (mph) 13.0-18.9 19.0-23.9

>24.0 3

0 0

4 3

0 6

0 0

4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 0

0 0

0 19 4

0 All Hours All Hours All Hours All Hours Report Printed On: 02/25/2020 09:47 All Hours Total 10 11 13 12 5

4 16 37 36 27 19 7

5 8

2 7

219 0

0 0

219 2184

Site:

VC Period of Record=

Elevation:

Stability Class:

Wind Direction N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total Speed:

SPlOTl D

0.8-3.9 6

4 4

3 7

16 7

12 23 15 12 7

14 7

139 Calm Hours not Included above for:

Variable Direction Hours for:

Invalid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

Page 4 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 04/01/2019 01:00

  • 07/01/2019 00:00 Direction:

DRlOTl Lapse:

DT61Tl Delta Temperature Neutral Wind Speed (mph) 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 10 8

0 0

13 5

0 0

8 6

4 0

0 4

13 5

0 0

10 7

0 0

0 11 2

0 0

0 51 12 0

0 0

55 20 0

0 0

46 20 3

0 73 9

4 0

0 47 10 1

0 0

16 5

0 0

0 7

2 0

0 0

4 0

0 0

3 2

0 0

0 4

3 3

0 0

362 125 22 1

0 Total Period All Hours Total Period All Hours Total Period All Hours Total Period All Hours Report Printed On: 02/25/2020 09:47 All Hours Total 25 23 22 25 18 14 70 91 77 98 81 36 21 12 19 17 649 0

0 0

649 2184

Site:

VC Report Printed On: 02/25/2020 09:47 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record=

04/01/2019 01:00 - 07/01/2019 00:00 Elevation:

Speed:

SPlOTl Direction:

DRlOTl Lapse:

DT61Tl Stability Class:

E Delta Temperature Slightly Stable Wind Speed (mph)

Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 Total N

5 3

2 1

0 0

11 NNE 5

2 0

0 0

0 7

NE 2

0 0

0 0

3 ENE 1

4 0

0 0

0 5

E 3

4 6

0 0

0 13 ESE 2

5 0

0 0

0 7

SE 5

32 0

0 0

0 37 SSE 14 50 1

0 0

0 65 s

15 28 0

0 0

44 SSW 16 46 0

0 0

63 SW 32 24 2

0 0

0 58 WSW 23 11 0

0 0

0 34 w

12 4

0 0

0 0

16 WNW 12 0

0 0

0 13 NW 10 13 0

0 0

0 23 NNW 2

4 0

0 0

0 6

Total 158 233 12 1

0 405 Calm Hours not lnclnded above for:

Total Period All Hours 0

Variable Direction Hours for:

Total Period All Hours 0

Invalid Hours for:

Total Period All Hours 0

Number of Valid Hours for this Table:

Total Period All Hours 405 Total Hours for the Period:

2184 Page 5 of 8

Site:

VC Report Printed On: 02/25/2020 09:47 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record=

04/01/2019 01:00 - 07/01/2019 00:00 Elevation:

Speed:

SPlOTl Direction:

DRlOTl Lapse:

DT61Tl Stability Class:

F Delta Temperature Moderately Stable Wind Speed (mph)

Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 Total N

2 0

0 0

0 0

2 NNE 0

0 0

0 0

0 0

NE 0

0 0

0 0

1 ENE 0

0 0

0 0

0 0

E 0

0 0

0 0

0 0

ESE 0

0 0

0 0

SE 1

4 0

0 0

0 5

SSE 6

13 0

0 0

0 19 s

14 12 0

0 0

0 26 SSW 13 15 0

0 0

0 28 SW 30 7

0 0

0 0

37 WSW 21 3

0 0

0 0

24 w

22 6

0 0

0 0

28 WNW 11 0

0 0

0 0

11 NW 8

0 0

0 0

9 NNW 0

0 0

0 0

1 Total 129 63 0

0 0

0 192 Calm Hours not Included above for:

Total Period All Hours 0

Variable Direction Hours for:

Total Period All Hours 0

Invalid Hours for:

Total Period All Hours 0

Number of Valid Hours for this Table:

Total Period All Hours 192 Total Hours for the Period:

2184 Page 6 of 8

Site:

VC Report Printed On: 02/25/2020 09:47 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record=

04/01/2019 01:00 - 07/01/2019 00:00 Elevation:

Speed:

SPlOTl Direction:

DRlOTl Lapse:

DT61Tl Stability Class:

G Delta Temperature Extremely Stable Wind Speed (mph)

Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 Total N

0 0

0 0

0 0

0 NNE 0

0 0

0 0

0 0

NE 0

0 0

0 0

0 0

ENE 0

0 0

0 0

0 0

E 0

0 0

0 0

0 0

ESE 0

0 0

0 0

0 0

SE 0

0 0

0 0

1 SSE 5

5 0

0 0

0 10 s

10 0

0 0

0 11 SSW 7

3 0

0 0

0 10 SW 13 0

0 0

0 0

13 WSW 16 3

0 0

0 0

19 w

9 0

0 0

0 10 WNW 4

0 0

0 0

0 4

NW 4

0 0

0 0

0 4

NNW 0

0 0

0 0

0 0

Total 69 13 0

0 0

0 82 Calm Hours not Included above for:

Total Period All Hours 0

Variable Direction Hours for:

Total Period All Hours 0

Invalid Hours for:

Total Period All Hours 0

Number of Valid Hours for this Table:

Total Period All Hours 82 Total Hours for the Period:

2184 Page 7 of 8

Site:

VC Period of Record=

Elevation:

Stability Class:

Wind Direction N,

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total Speed:

SPIOTI ALL 0.8-3.9 20 18 13 6

5 4

14 43 47 52 110 86 67 44 47 20 596 Calm Hours not Included above for:

Variable Direction Hours for:

Invalid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

Page 8 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 04/01/2019 01:00 - 07/01/2019 00:00 Direction:

DRIOTI Lapse:

DT61TI Delta Temperature Wind Speed (mph) 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 50 25 6

1 0

39 13 13 4

0 30 23 17 0

0 23 23 10 0

0 29 18 0

0 0

28 4

0 0

0 100 30 0

0 0

154 40 0

0 0

127 46 6

2 0

194 36 7

0 0

164 30 0

0 92 19 0

0 0

55 IO 0

0 35 6

1 0

0 40 3

0 1

0 19 9

4 0

0 1179 335 66 8

0 Total Period All Hours Total Period All Hours Total Period All Hours Total Period All Hours Report Printed On: 02/25/2020 09:47 All Hours Total 102 87 83

(,2 52 36 144 237 228 289 305 197 133 86 91 52 2184 0

0 0

2184 2184

Site:

VC Period of Record=

Elevation:

Stability Class:

Wind Direction N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total Speed:

SPlOTI A

0.8-3.9 18 IO 4

1 1

0 0

0 0

2 7

18 13 12 6

8 100 Calm Hours not Included above for:

Variable Direction Hours for:

Invalid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

Page 1 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 07/01/2019 01:00 - 10/01/2019 00:00 Direction:

DRIOTI Lapse:

DT61TI Delta Temperature Extremely Unstable Wind Speed (mph) 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 26 1

0 0

0 34 4

0 0

30 13 0

0 0

IO 6

0 0

0 4

2 0

0 0

0 0

0 0

0 0

0 0

0 0

2 2

0 0

0 8

4 0

0 0

12 1

0 0

0 46 2

0 0

0 44 0

0 0

0 19 0

0 0

0 8

2 0

0 0

9 0

0 0

0 9

0 0

0 261 38 0

0 Total Period All Hours Total Period All Hours Total Period All Hours Total Period All Hours Report Printed On: 02/25/2020 09:47 All Hours Total 45 49 47 17 7

0 0

4 12 15 55 62 32 22 15 18 400 0

0 5

400 2208

Site:

VC Period of Record=

Elevation:

Stability Class:

Wind Direction N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total Speed:

SPlOTl B

0.8-3.9 6

5 5

0 1

1 0

1 0

2 8

8 6

0 2

3 48 Calm Hours not Included above for:

Variable Direction Hours for:

Invalid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

Page 2 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 07/01/2019 01:00 - 10/01/2019 00:00 Direction:

. DRlOTl Lapse:

DT61Tl Delta Temperature 4.0-7.9 8.0-12.9 6

2 10 12 14 19 10 4

10 0

2 2

1 2

2 5

11 3

7 2

17 0

14 0

4 0

0 4

0 1

0 114 51 Total Period Total Period Total Period Total Period Moderately Unstable Wind Speed (mph) 13.0-18.9 19.0-23.9 5

11 2

11 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

23 7

All Hours All Hours All Hours All Hours

>24.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

Report Printed On: 02/25/2020 09:47 All Hours Total 20 40 49 14 11 5

3 8

14 11 25 22 10 1

6 4

243 0

0 5

243 2208

Site:

VC Period of Record=

Elevation:

Speed:

SPlOTl Stability Class:

C Wind Direction 0.8-3.9 N

2 NNE 9

NE 4

ENE 1

E 0

ESE 0

SE 2

SSE 1

s 1

SSW 2

SW 12 WSW 5

w 4

WNW 4

NW 4

NNW 4

Total 55 Calm Hours not Included above for:

Variable Direction Hours for:

Invalid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

Page 3 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 07/01/2019 01:00 - 10/01/2019 00:00 Direction:

DRlOTl Lapse:

DT61Tl Delta Temperature 4.0-7.9 8.0-12.9 4

7 11 10 10 4

8 6

6 7

6 3

2 0

1 2

87 Total Period Total Period Total Period Total Period 2

15 21 13 10 5

2 1

0 0

0 0

0 0

0 0

69 Slightly Unstable Wind Speed (mph) 13.0-18.9 1

4 3

1 0

0 0

0 0

0 0

0 0

0 0

0 9

19.0-23.9 0

1 0

0 0

0 0

0 0

0 0

0 0

0 0

0 All Hours All Hours All Hours All Hours

>24.0 3

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 3

Report Printed On: 02/25/2020 09:47 All Hours Total 12 36 39 25 20 9

12 8

7 9

18 8

6 4

5 6

224 0

0 5

224 2208

Site:

VC Period of Record=

Elevation:

Stability Class:

Wind Direction N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total Speed:

SPlOTl D

0.8-3.9 8

11 1

7 8

2 7

10 8

13 30 11 16 14 9

8 163 Calm Hours not Included above for:

Variable Direction Hours for:

Invalid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

Page 4 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 07/01/2019 01:00 - 10/01/2019 00:00 Direction:

DRlOTl Lapse:

DT61Tl Delta Temperature 4.0-7.9 8.0-12.9 18 23 15 35 30 23 27 23 36 70 31 12 5

4 4

357 Total Period Total Period Total Period Total Period 9

16 32 25 18 1

1 0

4 1

0 0

0 1

6 115 Neutral Wind Speed (mph) 13.0-18.9 2

2 1

0 0

0 0

0 0

0 0

0 0

0 2

8 19.0-23.9 1

1 0

0 0

0 0

0 0

0 0

0 0

0 0

1 3

All Hours All Hours All Hours All Hours

>24.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 Report Printed On: 02/25/2020 09:47 All Hours Total 39 53 49 68 56 26 35 33 45 87 62 23 21 15 14 21 647 0

0 5

647 2208

Site:

VC Period of Record=

Elevation:

Stability Class:

Wind Direction N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total Speed:

SPIOT1 E

0.8-3.9 3

6 3

6 5

8 9

27 18 30 47 35 37 18 13 4

269 Calm Hours not Included above for:

Variable Direction Hours for:

Invalid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

Page 5 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 07/01/2019 01:00 - 10/01/2019 00:00 Direction:

DRIOT1 Lapse:

DT61Tl Delta Temperature 4.0-7.9 1

6 1

1 9

4 8.0-12.9 26 36 20 28 8

8 1

1 6

6 162 Total Period Total Period Total Period Total Period 2

2 2

2 0

1 0

0 0

0 0

0 0

1 12 Slightly Stable Wind Speed (mph) 13.0-18.9 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

19.0-23.9 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

All Hours All Hours All Hours All Hours

>24.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

Report Printed On: 02/25/2020 09:47 All Hours Total 7

14 6

9 15 12 36 63 38 58 56 43 38 19 19 11 444 0

0 5

444 2208

Site:

VC Report Printed On: 02/25/2020 09:47 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record=

07/01/2019 01:00 - 10/01/2019 00:00 Elevation:

Speed:

SPlOTl Direction:

DRlOTl Lapse:

DT61Tl Stability Class:

F Delta Temperature Moderately Stable Wind Speed (mph)

Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 Total N

0 1

0 0

0 0

NNE 0

0 0

0 0

0 0

NE 0

0 0

0 0

ENE 0

0 0

0 0

E 0

0 0

0 0

0 0

ESE 1

0 0

0 0

0 1

SE 4

2 0

0 0

0 6

SSE 10 15 0

0 0

0 25 s

9 5

0 0

0 0

14 SSW 14 3

I 0

0 0

18 SW 18 0

0 0

20 WSW 18 0

0 0

0 0

18 w

18 2

0 0

0 0

20 WNW 15 1

0 0

0 0

16 NW 5

0 0

0 0

0 5

NNW 1

0 0

0 0

0 1

Total 115 30 1

0 0

147 Calm Hours not Included above for:

Total Period All Hours 0

Variable Direction Hours for:

Total Period All Hours 0

Invalid Hours for:

Total Period All Hours 5

Number of Valid Hours for this Table:

Total Period All Hours 147 Total Hours for the Period:

2208 Page 6 of 8

Site:

VC Report Printed On: 02/25/2020 09:4 7 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record=

07/01/2019 01:00 - 10/01/2019 00:00 Elevation:

Speed:

SPlOTl Direction:

DRlOTl Lapse:

DT61Tl Stability Class:

G Delta Temperature Extremely Stable Wind Speed (mph)

Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 Total N

0 0

0 0

0 0

0 NNE 0

0 0

0 0

1 NE 0

0 0

0 0

0 0

ENE 0

0 0

0 0

0 0

E 0

0 0

0 0

0 0

ESE 0

0 0

0 0

0 0

SE 0

0 0

0 0

0 0

SSE 2

3 0

0 0

0 5

s 6

0 0

0 0

0 6

SSW 6

0 0

0 0

0 6

SW 34 0

0 0

0 35 WSW 25 1

0 0

0 0

26 w

14 0

0 0

0 0

14 WNW 3

0 0

0 0

0 3

NW 0

0 0

0 0

NNW 0

0 0

0 0

Total 93 5

0 0

0 0

98 Calm Hours not Included above for:

Total Period All Hours 0

Variable Direction Hours for:

Total Period All Hours 0

Invalid Hours for:

Total Period All Hours 5

Number of Valid Hours for this Table:

Total Period All Hours 98 Total Hours for the Period:

2208 Page 7 of 8

Site:

VC Period of Record=

Elevation:

Stability Class:

Wind Direction N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total Speed:

SPlOTl ALL 0.8-3.9 37 42 18 16 15 12 22 51 42 69 156 120 108 66 40 29 843 Calm Hours not Included above for:

Variable Direction Hours for:

Invalid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

Page 8 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 07/01/2019 01:00 - 10/01/2019 00:00 Direction:

DRlOTl Lapse:

DT61Tl Delta Temperature Wind Speed (mph) 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 56 16 4

7 4

80 49 18 4

0 71 87 15 0

0 66 50 2

0 0

63 31 0

0 0

33 8

0 0

0 64 6

0 0

0 87 8

0 0

0 86 8

0 0

0 127 8

0 0

0 110 4

0 0

82 0

0 0

0 33 0

0 0

0 12 2

0 0

0 24 1

0 0

0 22 8

2 1

0 1016 286 42 12 4

Total Period All Hours Total Period All Hours Total Period All Hours Total Period All Hours Report Printed On: 02/25/2020 09:47 All Hours Total 124 193 191 134 109 53 92 146 136 204 271 202 141 80 65 62 2203 0

0 5

2203 2208

Site:

VC Period of Record =

Elevation:

Stability Class:

Wind Direction N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total Speed:

SPlOTl A

0.8-3.9 4

1 0

0 0

0 0

0 0

0 4

8 1

2 1

8 29 Calm Hours not Included above for:

Variable Direction Hours for:

Invalid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

Page 1 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 10/01/2019 01:00 - 01/01/2020 00:00 Direction:

DRlOTl Lapse:

DT61Tl Delta Temperature 4.0-7.9 8.0-12.9 6

2 3

4 2

1 0

0 0

0 0

0 1

0 0

0 6

4 12 6

19 4

12 10 1

9 4

6 5

87 33 Total Period Total Period Total Period Total Period Extremely Unstable Wind Speed (mph) 13.0-18.9 19.0-23.9 2

5 14 16 4

0 0

0 0

0 0

0 0

0 0

0 0

0 3

0 0

0 0

0 0

0 0

0 0

0 0

0 23 21 All Hours All Hours All Hours All Hours

>24.0 1

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 1

Report Printed On: 02/25/2020 09:48 All Hours Total 20 35 9

3 0

0 0

0 13 22 31 14 13 14 19 194 0

0 0

194 2208

Site:

VC Period of Record=

Elevation:

Stability Class:

Wind Direction N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total Speed:

SPlOTl B

0.8-3.9 3

4 3

2 0

0 0

o-0 4

5 3

3 30 Calm Hours not Included above for:

Variable Direction Hours for:

Invalid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

Page 2 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 10/01/2019 01:00

  • 01/01/2020 00:00 Direction:

DRlOTl Lapse:

DT61Tl Delta Temperature Moderately Unstable Wind Speed (mph) 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 9

9 4

2 0

6 24 32 9

0 10 22 23 0

0 4

14 2

0 0

1 2

0 0

0 1

4 0

0 0

0 1

0 0

0 3

0 0

0 0

2 2

0 0

0 2

5 3

0 0

5 4

0 0

0 5

3 0

0 0

3 0

0 0

0 2

0 0

0 0

2 4

0 0

0 7

1 0

0 0

62 95 64 11 0

Total Period All Hours Total Period All Hours Total Period All Hours Total Period All Hours Report Printed On: 02/25/2020 09:48 All Hours Total 27 75 58 22 3

6 3

4 10 10 12 8

3 9

11 262 0

0 0

262 2208

Site:

VC Report Printed On: 02/25/2020 09:48 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record=

10/01/2019 01:00 - 01/01/2020 00:00 Elevation:

Speed:

SPIOT1 Direction:

DRlOTl Lapse:

DT61Tl Stability Class:

C Delta Temperature Slightly Unstable Wind Speed (mph)

Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 Total N

5 13 9

9 2

0 38 NNE 3

13 32 IO 3

0 61 NE 4

16 61 6

0 0

87 ENE 2

5 26 2

0 0

35 E

0 11 5

2 0

0 18 ESE 5

0 0

0 7

SE 7

0 0

0 0

8 SSE 4

1 0

0 0

6 s

3 5

1 0

0 0

9 SSW 3

5 0

0 IO SW 3

2 0

0 0

6 WSW 2

0 2

0 0

0 4

w 1

2 0

0 0

0 3

WNW 2

2 0

0 0

0 4

NW 2

0 0

0 0

3 NNW 2

3 9

3 0

0 17 Total 33 91 154 33 5

0 316 Calm Hours not Included above for:

Total Period All Hours 0

Variable Direction Hours for:

Total Period All Hours 0

Invalid Hours for:

Total Period All Hours 0

Number of Valid Hours for this Table:

Total Period All Hours 316 Total Hours for the Period:

2208 Page 3 of 8

I Site:

VC Period of Record=

Elevation:

Stability Class:

Wind Direction N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW w

WNW NW NNW Total Speed:

SPlOTl D

0.8-3.9 13 7

3 4

2 7

5 8

10 10 7

5 16 7

10 115 Calm Hours not lnclnded above for:

Variable Direction Hours for:

Invalid Hours for:

  • Number of Valid Hours for this Table:

Total Hours for the Period:

Page 4 of 8 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 10/01/2019 01:00 - 01/01/2020 00:00 Direction:

DRlOTl Lapse:

DT61Tl Delta Temperature Neutral Wind Speed (mph) 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 10 3

1 0

12 8

13 4

0 20 17 17 2

2 28 29 8

1 1

53 20 0

0 0

24 2

0 0

0 30 4

0 0

0 33 6

0 0

0 13 21 0

0 0

15 19 3

0 0

14 5

0 0

0 26 4

0 0

0 24 2

0 0

0 9

0 0

0 0

22 2

0 0

0 13 4

0 0

346 146 43 8

3 Total Period All Hours Total Period All Hours Total Period All Hours Total Period All Hours Report Printed On: 02/25/2020 09:48 All Hours Total 28 44 61 71 74 28 41 44 42 47 29 37 31 25 31 28 661 0

0 0

661 2208

Site:

VC Report Printed On: 02/25/2020 09:48 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record=

10/01/2019 01:00 - 01/01/2020 00:00 Elevation:

Speed:

SPlOTl Direction:

DRIOTI Lapse:

DT61Tl Stability Class:

E Delta Temperature Slightly Stable Wind Speed (mph)

Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 Total N

7 3

2 0

0 0

12 NNE 6

7 3

0 2

1 19 NE 2

5 3

0 0

0 IO ENE 2

3 0

0 0

6 E

5 15 3

0 0

0 23 ESE 5

4 0

0 0

0 9

SE 3

12 0

0 0

0 15 SSE 10 19 0

0 0

0 29 s

15 22 0

0 0

38 SSW 16 23 0

0 0

40 SW 30 14 0

0 0

0 44 WSW 12 28 2

0 0

0 42 w

18 29 0

0 0

0 47 WNW 15 4

0 0

0 0

19 NW 12 8

0 0

0 0

20 NNW 3

2 0

0 0

0 5

Total 161 198 16 0

2 1

378 Calm Hours not Included above for:

Total Period All Hours 0

Variable Direction Hours for:

Total Period All Hours 0

Invalid Hours for:

Total Period All Hours 0

Number of Valid Hours for this Table:

Total Period All Hours 378 Total Hours for the Period:

2208 Page 5 of 8

Site:

VC Report Printed On: 02/25/2020 09:48 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record=

10/01/2019 01:00 - 01/01/2020 00:00 Elevation:

Speed:

SPlOTl Direction:

DRlOTl Lapse:

DT61Tl Stability Class:

F Delta Temperature Moderately Stable Wind Speed (mph)

Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 Total N

1 1

0 0

0 0

2 NNE 4

2 0

0 0

0 6

NE 0

1 0

0 0

0 ENE 0

0 0

0 0

1 E

4 0

0 0

0 0

4 ESE 4

0 0

0 0

0 4

SE 3

6 0

0 0

0 9

SSE 4

12 0

0 0

0 16 s

16 24 0

0 0

0 40 SSW 18 7

0 0

0 0

25 SW 21 2

0 0

0 0

23 WSW 13 2

0 0

0 0

15 w

10 4

0 0

0 0

14 WNW 17 0

0 0

0 0

17 NW 4

0 0

0 0

5 NNW 4

4 0

0 0

0 8

Total 124 66 0

0 0

0 190 Calm Honrs not Included above for:

Total Period All Hours 0

Variable Direction Honrs for:

Total Period All Hours 0

Invalid Hours for:

Total Period All Hours 0

Number of Valid Hours for this Table:

Total Period All Hours 190 Total Hours for the Period:

2208 Page 6 of 8

Site:

VC Report Printed On: 02/25/2020 09:48 Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period All Hours Period of Record= -

10/01/2019 01:00 - 01/01/2020 00:00 Elevation:

Speed:

SPlOTl Direction:

DRlOTl Lapse:

DT61Tl Stability Class:

G Delta Temperature Extremely Stable Wind Speed (mph)

Wind Direction 0.8-3.9 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 Total N

0 0

0 0

0 0

0 NNE 2

0 0

0 0

0 2

NE 0

0 0

0 0

0 0

ENE 1

0 0

0 0

0 1

E 0

0 0

0 0

0 0

ESE 1

0 0

0 0

0 SE 1

0 0

0 0

2 SSE 3

5 0

0 0

0 8

s 15 4

0 0

0 0

19 SSW 23 3

0 0

0 0

26 SW 42 3

0 0

0 0

45 WSW 56 2

0 0

0 0

58 w

30 0

0 0

0 0

30 WNW 9

0 0

0 0

0 9

NW 2

0 0

0 0

3 NNW 2

0 0

0 0

3 Total 187 20 0

0 0

0 207 Calm Hours not Included above for:

Total Period All Hours 0

Variable Direction Hours for:

Total Period All Hours 0

Invalid Hours for:

Total Period All Hours 0

Number of Valid Hours for this Table:

Total Period All Hours 207 Total Hours for the Period:

2208 Page 7 of 8

Site:

VC Period of Record=

Elevation:

Speed:

SPlOTl Stability Class:

ALL Wind Direction 0.8-3.9 N

33 NNE 27 NE 12 ENE 12 E

10 ESE 14 SE 15 SSE 23 s

57 SSW 70 SW 109 WSW 102 w

70 WNW 62 NW 31 NNW 32 Total 679 Calm Hours not Included above for:

Variable Direction Hours for:

Invalid Hours for:

Number of Valid Hours for this Table:

Total Hours for the Period:

I Page 8 of 8 I

Joint Frequency Distribution Hours at Each Wind Speed and Direction Total Period 10/01/2019 01:00 - 01/01/2020 00:00 Direction:

DRlOTl Lapse:

DT61Tl Delta Temperature Wind Speed (mph) 4.0-7.9 8.0-12.9 13.0-18.9 19.0-23.9

>24.0 42 25 16 10 1

43 68 69 34 1

53 107 50 2

2 42 71 12 1

1 80 30 2

0 0

34 7

0 0

0 56 5

0 0

0 77 7

0 0

0 70 25 0

0 0

57 34 10 0

0 53 17 0

0 0

82 15 0

0 0

74 3

0 0

0 27 1

0 0

0 44 10 0

0 0

36 19 4

0 0

870 444 163 47 5

Total Period All Hours Total Period All Hours Total Period All Hours Total Period All Hours Report Printed On: 02/25/2020 09:48 All Hours Total 127 242 226 139 122 55 76 107 152 171 179 199 147 90 85 91 2208 0

0 0

2208 2208