LR-N23-0054, In-Service Inspection Activities

From kanterella
Jump to navigation Jump to search
In-Service Inspection Activities
ML23207A156
Person / Time
Site: Salem PSEG icon.png
Issue date: 07/26/2023
From: Desanctis R
Public Service Enterprise Group
To:
Office of Nuclear Reactor Regulation, Document Control Desk
References
LR-N23-0054, N-532-5
Download: ML23207A156 (1)


Text

PSEG Nuclear LLC P.O. Box 236, Hancocks Br id ge, NJ 08038-0236

0 PSEG N11.clearLLC

ASME Code Case N-532-5 LR-N23-0054 July 26, 2023

U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington DC 20555-0001

Salem Generating Station Unit 2 Renewed Facility Operating License DPR -75 NRC Docket No. 50-311

Subject:

In-Service Inspection Activities

This letter submits the Owner's Activity Report for In - Service Inspection (ISi) activities conducted at the Salem Generating Station Unit 2 during the twenty-sixth refueling outage.

This report is submitted in accordance with Code Case N-532 -5 "Repair/Replacement Activity Documentation Requirements and In-Service Summary Report Preparation and Submission Section XI, Division 1".

to this letter contains the required Salem Unit 2 Owner 's Activity Report.

There are no commitments contained in this letter.

Should you have any questions regarding this submittal, please contact Ms. Bernadette Humphrey at 856 - 339-1308.

Sincerely,

Richard J. Desanctis Plant Manager - Salem

-Salem Unit 2 Owner's Activity Report - S2R26 LR-N23-0054 Page 2

cc: USNRC -Administrator -Region 1 USN RC - Licensing Project Manager - Salem USNRC Senior Resident Inspector NJDEP, Bureau of Nuclear Engineering Corporate Commitment Coordinator - PSEG LR-N23-0054

Enclosure 1

Salem Unit 2 Owner's Activity Report-S2R26 In Accordance With ASME Section XI Code Case N-532-5 LR - N23- 00 54 En c losure 1

FORM OAR-1 OWNER'S ACTIVITY REPORT

Report Number :,,S""2.... R,,_,2::.:6::..... ________ _____________ _ ______ _ ___ _

Plant Salem Generating Station

Unit No. ---=2'------ Commercial Service Date October 13, 1981 Refueling Outage no. ___ ~2=6"-----

IK o,,pllt>hl*>

Current Inspection Interval ISi - Fifth (5 th), GISI - Third (3 rd)

(1d, 2nd, 2nl. <<h, olhe,)

Current Inspection Period ISi - First (151), CISI - Second (2n~)

(l'2,2><1,:?.rrl)

Edition and Addenda of Section XI Applicable to the Inspection Plans 2013 Edition No Addenda

Date and Revision of Inspection Plans ISl(CISI) Revision 3, October 2022

Edition and Addenda of Section XI Applicable to Repair/Replacement Activities, If different than the Inspection Plans __ _

Same as ISi (CIS() Plan.

Code cases used for inspection and evaluation : N-532-5, N-716-1, N-729-6 1 N-770-5, N-854 & N-892

CERTIFICAlE OF CONFORMANCE

I certify that (a) the statements made In this report are correct; (b) lhe examinations and tesls meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repair/replacement activities and evaluations supporting the completlon of S2R26 Conform 1o the requirements of Section XI. (R..iuo r"'ll OV.OSIC number)

Signed Edley T Giles/ ISi Program Owner Date 7/dzo23

CERTIRCATE OF INSERVICE INSPECTION

I, the undersigned, holding a valid commission issuod by the National Board of Bo iler and Pressure Vessel Inspectors and employed bvHartford Steam Boiler Inspection and Insurance Company of Hartford. Connecticut have lnspec;ted the items desc;n"bed in 'this Owner's Activity Report, nnd slato that, to the best of my knowledge and belief, the Owner has performed all activilies represented by this report In accordance with the requirements of Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or hnplled, concornlng the ropalr/raplacemont activitie s and evaluation describod In this report. FurtheITnore, neither the In spector nor his employer shall be liable In any manner for any personal Injury or roperty damage or a Joss of any kind arising from or connected with this lnspeatlon.

.1D~a!!!n[!!ie~l~C~a~[!Q!~~~~__l~~~?Z:=::::::.._ ____ Commission NB16247,N, I, R / NJ1238 (l-""""' Nu,:\\!>~ cnd ~--,

OatefZ Ju (

LR-N23-0054 FORM OAR-1 OWNER'S ACTIVITY REPORT

TABLE1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE

Exam Item Item Description Evaluation Description Category Number

none none none none

TABLE2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Item Description of Work Date Repair /Replacement Code Class Description Complete Plan Number,

3 ASME leak identified in 3/8 inch Replaced 3/8" stainless steel 12/28/2022 60150922 Stainless Steel tubing tubing downstream of valve downstream of Valve 25SW73 25SW73.

which goes to RAD Monitor 2RA9853.

- 2 -