LR-N22-0013, In-Service Inspection Activities - 90-Day Report

From kanterella
Jump to navigation Jump to search
In-Service Inspection Activities - 90-Day Report
ML22040A367
Person / Time
Site: Salem PSEG icon.png
Issue date: 02/10/2022
From: Desanctis R
Public Service Enterprise Group
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
LR-N22-0013
Download: ML22040A367 (5)


Text

PSEG Nuclear LLC P.O. Box 236, Hancocks Bridge, NJ 08038-0236 0 PSEG NuclearLLC ASME Code Case N-532-5 February 10, 2022 LR-N22-0013 U.S. Nuclear Regulatory Commission ATTN : Document Control Desk Washington DC 20555-0001 Salem Generating Station Unit 2 Renewed Facility Operating License DPR-75 NRC Docket No. 50-311

Subject:

In-Service Inspection Activities Day Report This letter submits the Owner's Activity Report for In-Service Inspection (ISi) activities conducted at the Salem Generating Station Unit 2 during the twenty-fifth refueling outage.

This report is submitted in accordance with Code Case N-532-5 "Repair/Replacement Activity Documentation Requirements and In-Service Summary Report Preparation and Submission Section XI , Division 1," and within its ninety day reporting requirement. to this letter contains the required Salem Unit 2 Owner's Activity Report.

There are no commitments contained in this letter.

Should you have any questions regarding this submittal , please contact Ms. Bernadette Humphrey at 856-339-1308.

Sincerely, Richard J . Desanctis Plant Manager- Salem Salem Generating Station Enclosure

LR-N22-0013 Page 2 cc: USNRC -Administrator-Region 1 USNRC -Licensing Project Manager-Salem USNRC Senior Resident Inspector Chief, NJBNE Salem Commitment Tracking Coordinator Corporate Commitment Tracking Coordinator Chief Inspector- Occupational Safety and Health Bureau of Boiler and Pressure Vessel Compliance LR-N22-0013 Salem Unit 2 Owner's Activity Report - S2RFO25 In Accordance With ASME Section XI Code Case N-532-5

FORM OAR-1 OWNER'S ACTIVITY REPORT Report Number~S=2~R=F~O~2=5_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

Plant Salem Generating Station Unit No. ~2~------ Commercial service date October 13, 1981 Refueling outage no . ...,,2..,,5<---------

or applicable)

Current inspection interval ISi - Fourth (4th ), CISI - Third (3 rd )

(1s1, 2nd, 3rd, 41h, other)

Current inspection period ISi - Third (3 rd ), CISI - First (1 st )

(1sl, 2nd, 3rd)

Edition and Addenda of Section XI applicable to the inspection plans ISi 2004 Edition, CISI 2013 Edition Date and revision of inspection plans ISi Revision 6 1 August 2021 1 CISI Revision 0 1 February 2021 Edition and Addenda of Section XI applicable to repair/replacement activities, if different than the inspection plans _ _ __

Same as ISi and CISI Plans Code Cases used for inspection and evaluation: N-460, N-532-5, N-566-2, N-613-2, N-648-2, N-695-1, N-696-1, N-716-1.N-722-1, N-731. N-770-5, N-798, N-800 N-845 & N-854 Qf appllcable, Including cases modified by Case N-532 and later revisions)

CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section XI; and (c) the repair/replacement activities and evaluations supporting the completion of -=S:.::2:.:.R.a:F_0;..;25"'------

(refueling outage number)

Conform to the requirements of Section XI.

Signed Edie T Giles / ISi Pro ram Owner Date Owner or owner's Desi nee Tille CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and employed by Hartford Steam Boiler Inspection and Insurance Company of Hartford, Connecticut have inspected the Items described in this Owner's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described In this report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date t(~t ('ZoZ-Z...

-1*

FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Exam Item Item Description Evaluation Description Category Number N-770-5 B-2 Reactor Pressure ASME-IWB-3600 Acceptability Evaluation for Vessel No. 23 Cold inside diameter connected planar flaw, Order Leg Nozzle to Safe- 70220273 End Alloy 600 Weld (weld not mitii:1ated)

B-N-3 B13.70 Reactor Pressure Operability Assessment for Degraded Clevis Vessel Lower Radial Insert Bolts at Salem Unit 2, Order 70220082 Support Clevis Assembly at 60°,

two Clevis Insert Bolts degraded TABLE2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Item Description of Work Date Repair/Replacement Code Description Completed Plan Number Class 3 Through-wall leak Replaced 3/8" stainless 10/22/2020 60147894 identified on 3/8" steel capillary tubing at stainless steel capillary leak location.

t, Ibing between panel 234 and root valve 22SJ24 caused by fretting.

3 3/8" stainless steel Replaced Valve 2SW340 02/12/2021 60148597 instrument line to and 3/8" stainless steel pressure gauge tubing to pressure gauge 2PL9283 was found 2PL9283.

broken off at its tie in connection at outlet of isolation valve 2SW340.

MC License Renewal Performed weld overlay of 01/25/2022 60142730 inspection of 6 inch by 6 inch area to containment liner restore liner plate to beneath insulation nominal thickness.

system was found corroded just below design minimum wall thickness, not through wall.