IR 05000443/1978013
ML20148G036 | |
Person / Time | |
---|---|
Site: | Seabrook ![]() |
Issue date: | 09/27/1978 |
From: | Folsom S NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
To: | |
Shared Package | |
ML20148G033 | List: |
References | |
50-443-78-13, 50-444-78-13, NUDOCS 7811100097 | |
Download: ML20148G036 (5) | |
Similar Documents at Seabrook | |
---|---|
Category:INSPECTION REPORT
MONTHYEARIR 05000443/19990101999-09-24024 September 1999
[Table view]Insp Rept 50-443/99-10 on 990726-30 & 0809-13.No Violations Noted.Major Areas Inspected:Corrective Action Program IR 05000443/19990051999-08-25025 August 1999 Insp Rept 50-443/99-05 on 990621-0801.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000443/19990061999-07-26026 July 1999 Insp Rept 50-443/99-06 on 990510-0620.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support,Including Security Controls ML20196E0261999-06-21021 June 1999 Insp Rept 50-443/99-01 on 990321-0509.Violations Noted. Major Areas Inspected:Aspects of Licensee Operations,Maint, Engineering & Plant Support IR 05000443/19990031999-05-20020 May 1999 Insp Rept 50-443/99-03 on 990308-0408.Non-cited Violations Noted.Major Areas Inspected:Licensee Engineering Activities Which Included in-depth Review of PCCW Sys IR 05000443/19990011999-04-20020 April 1999 Insp Rept 50-443/99-01 on 990207-0321.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000443/19980111999-02-26026 February 1999 Insp Rept 50-443/98-11 on 981228-990207.No Violations Noted.Major Areas Inspected:Licensee Operations,Engineering, Maint & Plant Support IR 05000443/19980101999-01-28028 January 1999 Insp Rept 50-443/98-10 on 981115-1227.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000443/19980091998-12-11011 December 1998 Insp Rept 50-443/98-09 on 981004-1114.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000443/19980061998-11-0606 November 1998 Insp Rept 50-443/98-06 on 980823-1003.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000443/19980081998-10-16016 October 1998 Insp Rept 50-443/98-08 on 980921-25.No Violations Noted. Major Areas Inspected:Long Term MOV Program Under GL 89-10 Program at Seabrook Station & Will Review long-term MOV Program Under GL 96-05 IR 05000443/19980071998-10-0202 October 1998 Errata to Insp Rept 50-443/98-07 on 980803-07,including Coversheet & Executive Summary Pages ML20154B1681998-09-28028 September 1998 Insp Rept 50-443/98-09 on 980803-07.Violations Noted.Major Areas inspected:medium-voltage & low-voltage Power Circuit Breakers IR 05000443/19980051998-09-25025 September 1998 Insp Rept 50-443/98-05 on 980705-0822.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support Re Licensee Security Facilities & Equipment in Areas of Protective Area Assessment Aids IR 05000443/19980041998-07-30030 July 1998 Insp Rept 50-443/98-04 on 980517-0704.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000443/19980031998-07-0909 July 1998 Insp Rept 50-443/98-03 on 980602-04.No Violations Noted. Major Areas Inspected:Insp Observed & Evaluated Licensee Biennial full-participation Exercise in Simulator Control Room,Technical Support Ctr & Operations Support Ctr IR 05000443/19980021998-06-12012 June 1998 Insp Rept 50-443/98-02 on 980329-0516.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maint & Plant Support ML20217L8311998-04-27027 April 1998 Insp Rept 50-443/98-01 on 980201-0328.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support ML20216B1271998-02-27027 February 1998 Insp Rept 50-443/97-08 on 971212-980131.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000443/19970091998-02-20020 February 1998 Insp Rept 50-443/97-09 on 971215-18 & 980120-21.Violations Noted.Major Areas Inspected:Maint IR 05000443/19970071998-01-0707 January 1998 Insp Rept 50-443/97-07 on 971005-1206.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maint & Plant Support Re Implementation of Security Program IR 05000443/19970061997-11-20020 November 1997 Insp Rept 50-443/97-06 on 970816-1004.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering, Maint & Plant Support IR 05000443/19970051997-10-27027 October 1997 Insp Rept 50-443/97-05 on 970825-0910.No Violations Noted. Major Areas Inspected:Process of Operating Experience, Trending,Tagging & self-assesment ML20211G0121997-09-23023 September 1997 Insp Rept 50-443 on 970616-0815.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support & Emergency Preparedness Program IR 05000443/19970031997-08-13013 August 1997 Corrected Insp Rept 50-443/97-03 Consisting of Changes to Section S1.2.c ML20196J6691997-07-30030 July 1997 Insp Rept 50-443/97-03 on 970415-0615.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20140D1281997-05-30030 May 1997 Insp Rept 50-443/97-02 on 970304-0414.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000443/19970011997-04-0808 April 1997 Insp Rept 50-443/97-01 on 970114-0303.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000443/19960111997-03-0707 March 1997 Insp Rept 50-443/96-11 on 961130-970113.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20133A5461996-12-24024 December 1996 Insp Rept 50-443/96-10 on 961001-1129.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering,Plant Support & Assurance of Quality IR 05000443/19960081996-11-22022 November 1996 Insp Rept 50-443/96-08 on 960813-0930.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000443/19960121996-11-0707 November 1996 Insp Rept 50-443/96-12 on 961021-25.No Violations Noted. Major Areas Insp:Organizational Charts,Applicable Procedures & Interviews IR 05000443/19960071996-10-31031 October 1996 Insp Rept 50-443/96-07 on 960916-20.No Violations Noted. Major Areas Inspected:Licensee Er Organization During Biennial,Full Participation Exercise in Simulator Control Room,Tsc,Ocs & EOF IR 05000443/19930211994-01-0606 January 1994 Insp Rept 50-443/93-21 on 931109-1206.No Violations Noted. Major Areas Inspected:Station Performance in Areas of Operation,Maint,Engineering,Plant Support & Safety Assessment/Quality Verification IR 05000443/19930191993-11-12012 November 1993 Insp Rept 50-443/93-19 on 931005-1108.Violation Noted But Not Cited.Major Areas Inspected:Assessment of Station Performance in Areas of Plant Operations,Maint,Engineering, Plant Support,Safety Assessment & Quality Verification IR 05000443/19930181993-10-20020 October 1993 Insp Rept 50-443/93-18 on 930927-1001.No Violations Noted. Major Areas Inspected:Fire Protection Program & Implementation in Areas of Administration Controls, Surveillances,Combustible Controls,Testing & Audits IR 05000443/19930141993-10-18018 October 1993 Insp Rept 50-443/93-14 on 930913-17.No Violations Noted. Major Areas Inspected:Whether Licensee Design,Installation & Mod of safety-related Piping & Pipe Supports Were Performed Per Regulatory Requirements IR 05000443/19930171993-10-15015 October 1993 Insp Rept 50-443/93-17 on 930829-1004.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering,Plant Support & Safety Assessment & Quality Verification IR 05000443/19930111993-10-12012 October 1993 Errata to Page 8 of Insp Rept 50-443/93-11 IR 05000443/19930161993-09-10010 September 1993 Insp Rept 50-443/93-16 on 930727-0828.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000443/19930131993-08-17017 August 1993 Insp Rept 50-443/93-13 on 930615-0726.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering,Plant Support & Safety Assessment IR 05000443/19930121993-08-12012 August 1993 Insp Rept 50-443/93-12 on 930622-23 & 0726-28.No Violations Noted.Major Areas Inspected:Adequacy of Auxiliary Operator Remedial Training Program & Modified Operator Requalification Training Program IR 05000443/19920241993-02-0404 February 1993 Insp Rept 50-443/92-24 on 921222-930125.Major Areas Inspected:Operations,Radiological Controls,Emergency Preparedness,Maint/Surveillance,Security,Engineering/ Technical Support & Safety Assessment/Quality Verification IR 05000443/19930011993-01-25025 January 1993 Insp Rept 50-443/93-01 on 930103-20.Licensee Assessment of Event Thorough & Well Documented.Major Areas Inspected: Events Leading Up to Loss of Both Main Feedwater Pumps & Subsequent Manual Trip of Reactor IR 05000443/19920271993-01-12012 January 1993 Insp Rept 50-443/92-27 on 921117-1221.No Violations Noted. Major Areas Inspected:Conducted Daily CR Tours,Observed Shift Turnovers,Attended Morning Station Managers Meeting, EDG Rooms & Condensate Storage Tank Bldg IR 05000443/19920261992-12-22022 December 1992 Insp Rept 50-443/92-26 on 921023-30.No Violations Noted. Major Areas Inspected:Review of Cilrt & LLRT Procedures, Witness Cilrt & LLRT Test & Review Cilrt & LLRT Test Results IR 05000443/19920251992-12-0101 December 1992 Insp Rept 50-443/92-25 on 921013-1116.Violations Noted. Major Areas Inspected:Summary of Activities,Radiation Controls,Security,Ep & Plant Operations IR 05000443/19920221992-11-27027 November 1992 Insp Rept 50-443/92-22 on 921005-09.One non-cited Violation Noted.Major Areas Inspected:Radiological Controls Program, Predominately Involving Observation of Field Activities During 1992 Refueling Outage & Review of HP Program IR 05000443/19900221990-10-26026 October 1990 Insp Rept 50-443/90-22 on 901009-12.No Violations Noted. Major Areas Inspected:Design Implementation Verification & Surveillance Test Procedures IR 05000443/19900171990-10-24024 October 1990 Insp Rept 50-443/90-17 on 900905-1014.Major Areas Inspected: Operations,Radiological Controls,Maint/Surveillance & Security 1999-09-24 Category:NRC-GENERATED MONTHYEARIR 05000443/19990101999-09-24024 September 1999
[Table view]Insp Rept 50-443/99-10 on 990726-30 & 0809-13.No Violations Noted.Major Areas Inspected:Corrective Action Program IR 05000443/19990051999-08-25025 August 1999 Insp Rept 50-443/99-05 on 990621-0801.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000443/19990061999-07-26026 July 1999 Insp Rept 50-443/99-06 on 990510-0620.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support,Including Security Controls ML20196E0261999-06-21021 June 1999 Insp Rept 50-443/99-01 on 990321-0509.Violations Noted. Major Areas Inspected:Aspects of Licensee Operations,Maint, Engineering & Plant Support IR 05000443/19990031999-05-20020 May 1999 Insp Rept 50-443/99-03 on 990308-0408.Non-cited Violations Noted.Major Areas Inspected:Licensee Engineering Activities Which Included in-depth Review of PCCW Sys IR 05000443/19990011999-04-20020 April 1999 Insp Rept 50-443/99-01 on 990207-0321.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000443/19980111999-02-26026 February 1999 Insp Rept 50-443/98-11 on 981228-990207.No Violations Noted.Major Areas Inspected:Licensee Operations,Engineering, Maint & Plant Support IR 05000443/19980101999-01-28028 January 1999 Insp Rept 50-443/98-10 on 981115-1227.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000443/19980091998-12-11011 December 1998 Insp Rept 50-443/98-09 on 981004-1114.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000443/19980061998-11-0606 November 1998 Insp Rept 50-443/98-06 on 980823-1003.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000443/19980081998-10-16016 October 1998 Insp Rept 50-443/98-08 on 980921-25.No Violations Noted. Major Areas Inspected:Long Term MOV Program Under GL 89-10 Program at Seabrook Station & Will Review long-term MOV Program Under GL 96-05 IR 05000443/19980071998-10-0202 October 1998 Errata to Insp Rept 50-443/98-07 on 980803-07,including Coversheet & Executive Summary Pages ML20154B1681998-09-28028 September 1998 Insp Rept 50-443/98-09 on 980803-07.Violations Noted.Major Areas inspected:medium-voltage & low-voltage Power Circuit Breakers IR 05000443/19980051998-09-25025 September 1998 Insp Rept 50-443/98-05 on 980705-0822.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support Re Licensee Security Facilities & Equipment in Areas of Protective Area Assessment Aids IR 05000443/19980041998-07-30030 July 1998 Insp Rept 50-443/98-04 on 980517-0704.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000443/19980031998-07-0909 July 1998 Insp Rept 50-443/98-03 on 980602-04.No Violations Noted. Major Areas Inspected:Insp Observed & Evaluated Licensee Biennial full-participation Exercise in Simulator Control Room,Technical Support Ctr & Operations Support Ctr IR 05000443/19980021998-06-12012 June 1998 Insp Rept 50-443/98-02 on 980329-0516.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maint & Plant Support ML20217L8311998-04-27027 April 1998 Insp Rept 50-443/98-01 on 980201-0328.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support ML20216B1271998-02-27027 February 1998 Insp Rept 50-443/97-08 on 971212-980131.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000443/19970091998-02-20020 February 1998 Insp Rept 50-443/97-09 on 971215-18 & 980120-21.Violations Noted.Major Areas Inspected:Maint IR 05000443/19970071998-01-0707 January 1998 Insp Rept 50-443/97-07 on 971005-1206.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maint & Plant Support Re Implementation of Security Program IR 05000443/19970061997-11-20020 November 1997 Insp Rept 50-443/97-06 on 970816-1004.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering, Maint & Plant Support IR 05000443/19970051997-10-27027 October 1997 Insp Rept 50-443/97-05 on 970825-0910.No Violations Noted. Major Areas Inspected:Process of Operating Experience, Trending,Tagging & self-assesment ML20211G0121997-09-23023 September 1997 Insp Rept 50-443 on 970616-0815.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support & Emergency Preparedness Program IR 05000443/19970031997-08-13013 August 1997 Corrected Insp Rept 50-443/97-03 Consisting of Changes to Section S1.2.c ML20196J6691997-07-30030 July 1997 Insp Rept 50-443/97-03 on 970415-0615.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20140D1281997-05-30030 May 1997 Insp Rept 50-443/97-02 on 970304-0414.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000443/19970011997-04-0808 April 1997 Insp Rept 50-443/97-01 on 970114-0303.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000443/19960111997-03-0707 March 1997 Insp Rept 50-443/96-11 on 961130-970113.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20133A5461996-12-24024 December 1996 Insp Rept 50-443/96-10 on 961001-1129.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering,Plant Support & Assurance of Quality IR 05000443/19960081996-11-22022 November 1996 Insp Rept 50-443/96-08 on 960813-0930.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000443/19960121996-11-0707 November 1996 Insp Rept 50-443/96-12 on 961021-25.No Violations Noted. Major Areas Insp:Organizational Charts,Applicable Procedures & Interviews IR 05000443/19960071996-10-31031 October 1996 Insp Rept 50-443/96-07 on 960916-20.No Violations Noted. Major Areas Inspected:Licensee Er Organization During Biennial,Full Participation Exercise in Simulator Control Room,Tsc,Ocs & EOF IR 05000443/19930211994-01-0606 January 1994 Insp Rept 50-443/93-21 on 931109-1206.No Violations Noted. Major Areas Inspected:Station Performance in Areas of Operation,Maint,Engineering,Plant Support & Safety Assessment/Quality Verification IR 05000443/19930191993-11-12012 November 1993 Insp Rept 50-443/93-19 on 931005-1108.Violation Noted But Not Cited.Major Areas Inspected:Assessment of Station Performance in Areas of Plant Operations,Maint,Engineering, Plant Support,Safety Assessment & Quality Verification IR 05000443/19930181993-10-20020 October 1993 Insp Rept 50-443/93-18 on 930927-1001.No Violations Noted. Major Areas Inspected:Fire Protection Program & Implementation in Areas of Administration Controls, Surveillances,Combustible Controls,Testing & Audits IR 05000443/19930141993-10-18018 October 1993 Insp Rept 50-443/93-14 on 930913-17.No Violations Noted. Major Areas Inspected:Whether Licensee Design,Installation & Mod of safety-related Piping & Pipe Supports Were Performed Per Regulatory Requirements IR 05000443/19930171993-10-15015 October 1993 Insp Rept 50-443/93-17 on 930829-1004.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering,Plant Support & Safety Assessment & Quality Verification IR 05000443/19930111993-10-12012 October 1993 Errata to Page 8 of Insp Rept 50-443/93-11 IR 05000443/19930161993-09-10010 September 1993 Insp Rept 50-443/93-16 on 930727-0828.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000443/19930131993-08-17017 August 1993 Insp Rept 50-443/93-13 on 930615-0726.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering,Plant Support & Safety Assessment IR 05000443/19930121993-08-12012 August 1993 Insp Rept 50-443/93-12 on 930622-23 & 0726-28.No Violations Noted.Major Areas Inspected:Adequacy of Auxiliary Operator Remedial Training Program & Modified Operator Requalification Training Program IR 05000443/19920241993-02-0404 February 1993 Insp Rept 50-443/92-24 on 921222-930125.Major Areas Inspected:Operations,Radiological Controls,Emergency Preparedness,Maint/Surveillance,Security,Engineering/ Technical Support & Safety Assessment/Quality Verification IR 05000443/19930011993-01-25025 January 1993 Insp Rept 50-443/93-01 on 930103-20.Licensee Assessment of Event Thorough & Well Documented.Major Areas Inspected: Events Leading Up to Loss of Both Main Feedwater Pumps & Subsequent Manual Trip of Reactor IR 05000443/19920271993-01-12012 January 1993 Insp Rept 50-443/92-27 on 921117-1221.No Violations Noted. Major Areas Inspected:Conducted Daily CR Tours,Observed Shift Turnovers,Attended Morning Station Managers Meeting, EDG Rooms & Condensate Storage Tank Bldg IR 05000443/19920261992-12-22022 December 1992 Insp Rept 50-443/92-26 on 921023-30.No Violations Noted. Major Areas Inspected:Review of Cilrt & LLRT Procedures, Witness Cilrt & LLRT Test & Review Cilrt & LLRT Test Results IR 05000443/19920251992-12-0101 December 1992 Insp Rept 50-443/92-25 on 921013-1116.Violations Noted. Major Areas Inspected:Summary of Activities,Radiation Controls,Security,Ep & Plant Operations IR 05000443/19920221992-11-27027 November 1992 Insp Rept 50-443/92-22 on 921005-09.One non-cited Violation Noted.Major Areas Inspected:Radiological Controls Program, Predominately Involving Observation of Field Activities During 1992 Refueling Outage & Review of HP Program IR 05000443/19900221990-10-26026 October 1990 Insp Rept 50-443/90-22 on 901009-12.No Violations Noted. Major Areas Inspected:Design Implementation Verification & Surveillance Test Procedures IR 05000443/19900171990-10-24024 October 1990 Insp Rept 50-443/90-17 on 900905-1014.Major Areas Inspected: Operations,Radiological Controls,Maint/Surveillance & Security 1999-09-24 Category:INSPECTION REPORT MONTHYEARIR 05000443/19990101999-09-24024 September 1999
[Table view]Insp Rept 50-443/99-10 on 990726-30 & 0809-13.No Violations Noted.Major Areas Inspected:Corrective Action Program IR 05000443/19990051999-08-25025 August 1999 Insp Rept 50-443/99-05 on 990621-0801.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000443/19990061999-07-26026 July 1999 Insp Rept 50-443/99-06 on 990510-0620.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support,Including Security Controls ML20196E0261999-06-21021 June 1999 Insp Rept 50-443/99-01 on 990321-0509.Violations Noted. Major Areas Inspected:Aspects of Licensee Operations,Maint, Engineering & Plant Support IR 05000443/19990031999-05-20020 May 1999 Insp Rept 50-443/99-03 on 990308-0408.Non-cited Violations Noted.Major Areas Inspected:Licensee Engineering Activities Which Included in-depth Review of PCCW Sys IR 05000443/19990011999-04-20020 April 1999 Insp Rept 50-443/99-01 on 990207-0321.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000443/19980111999-02-26026 February 1999 Insp Rept 50-443/98-11 on 981228-990207.No Violations Noted.Major Areas Inspected:Licensee Operations,Engineering, Maint & Plant Support IR 05000443/19980101999-01-28028 January 1999 Insp Rept 50-443/98-10 on 981115-1227.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000443/19980091998-12-11011 December 1998 Insp Rept 50-443/98-09 on 981004-1114.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000443/19980061998-11-0606 November 1998 Insp Rept 50-443/98-06 on 980823-1003.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000443/19980081998-10-16016 October 1998 Insp Rept 50-443/98-08 on 980921-25.No Violations Noted. Major Areas Inspected:Long Term MOV Program Under GL 89-10 Program at Seabrook Station & Will Review long-term MOV Program Under GL 96-05 IR 05000443/19980071998-10-0202 October 1998 Errata to Insp Rept 50-443/98-07 on 980803-07,including Coversheet & Executive Summary Pages ML20154B1681998-09-28028 September 1998 Insp Rept 50-443/98-09 on 980803-07.Violations Noted.Major Areas inspected:medium-voltage & low-voltage Power Circuit Breakers IR 05000443/19980051998-09-25025 September 1998 Insp Rept 50-443/98-05 on 980705-0822.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support Re Licensee Security Facilities & Equipment in Areas of Protective Area Assessment Aids IR 05000443/19980041998-07-30030 July 1998 Insp Rept 50-443/98-04 on 980517-0704.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000443/19980031998-07-0909 July 1998 Insp Rept 50-443/98-03 on 980602-04.No Violations Noted. Major Areas Inspected:Insp Observed & Evaluated Licensee Biennial full-participation Exercise in Simulator Control Room,Technical Support Ctr & Operations Support Ctr IR 05000443/19980021998-06-12012 June 1998 Insp Rept 50-443/98-02 on 980329-0516.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maint & Plant Support ML20217L8311998-04-27027 April 1998 Insp Rept 50-443/98-01 on 980201-0328.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support ML20216B1271998-02-27027 February 1998 Insp Rept 50-443/97-08 on 971212-980131.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000443/19970091998-02-20020 February 1998 Insp Rept 50-443/97-09 on 971215-18 & 980120-21.Violations Noted.Major Areas Inspected:Maint IR 05000443/19970071998-01-0707 January 1998 Insp Rept 50-443/97-07 on 971005-1206.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maint & Plant Support Re Implementation of Security Program IR 05000443/19970061997-11-20020 November 1997 Insp Rept 50-443/97-06 on 970816-1004.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering, Maint & Plant Support IR 05000443/19970051997-10-27027 October 1997 Insp Rept 50-443/97-05 on 970825-0910.No Violations Noted. Major Areas Inspected:Process of Operating Experience, Trending,Tagging & self-assesment ML20211G0121997-09-23023 September 1997 Insp Rept 50-443 on 970616-0815.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support & Emergency Preparedness Program IR 05000443/19970031997-08-13013 August 1997 Corrected Insp Rept 50-443/97-03 Consisting of Changes to Section S1.2.c ML20196J6691997-07-30030 July 1997 Insp Rept 50-443/97-03 on 970415-0615.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20140D1281997-05-30030 May 1997 Insp Rept 50-443/97-02 on 970304-0414.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000443/19970011997-04-0808 April 1997 Insp Rept 50-443/97-01 on 970114-0303.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000443/19960111997-03-0707 March 1997 Insp Rept 50-443/96-11 on 961130-970113.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20133A5461996-12-24024 December 1996 Insp Rept 50-443/96-10 on 961001-1129.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering,Plant Support & Assurance of Quality IR 05000443/19960081996-11-22022 November 1996 Insp Rept 50-443/96-08 on 960813-0930.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support IR 05000443/19960121996-11-0707 November 1996 Insp Rept 50-443/96-12 on 961021-25.No Violations Noted. Major Areas Insp:Organizational Charts,Applicable Procedures & Interviews IR 05000443/19960071996-10-31031 October 1996 Insp Rept 50-443/96-07 on 960916-20.No Violations Noted. Major Areas Inspected:Licensee Er Organization During Biennial,Full Participation Exercise in Simulator Control Room,Tsc,Ocs & EOF IR 05000443/19930211994-01-0606 January 1994 Insp Rept 50-443/93-21 on 931109-1206.No Violations Noted. Major Areas Inspected:Station Performance in Areas of Operation,Maint,Engineering,Plant Support & Safety Assessment/Quality Verification IR 05000443/19930191993-11-12012 November 1993 Insp Rept 50-443/93-19 on 931005-1108.Violation Noted But Not Cited.Major Areas Inspected:Assessment of Station Performance in Areas of Plant Operations,Maint,Engineering, Plant Support,Safety Assessment & Quality Verification IR 05000443/19930181993-10-20020 October 1993 Insp Rept 50-443/93-18 on 930927-1001.No Violations Noted. Major Areas Inspected:Fire Protection Program & Implementation in Areas of Administration Controls, Surveillances,Combustible Controls,Testing & Audits IR 05000443/19930141993-10-18018 October 1993 Insp Rept 50-443/93-14 on 930913-17.No Violations Noted. Major Areas Inspected:Whether Licensee Design,Installation & Mod of safety-related Piping & Pipe Supports Were Performed Per Regulatory Requirements IR 05000443/19930171993-10-15015 October 1993 Insp Rept 50-443/93-17 on 930829-1004.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering,Plant Support & Safety Assessment & Quality Verification IR 05000443/19930111993-10-12012 October 1993 Errata to Page 8 of Insp Rept 50-443/93-11 IR 05000443/19930161993-09-10010 September 1993 Insp Rept 50-443/93-16 on 930727-0828.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000443/19930131993-08-17017 August 1993 Insp Rept 50-443/93-13 on 930615-0726.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering,Plant Support & Safety Assessment IR 05000443/19930121993-08-12012 August 1993 Insp Rept 50-443/93-12 on 930622-23 & 0726-28.No Violations Noted.Major Areas Inspected:Adequacy of Auxiliary Operator Remedial Training Program & Modified Operator Requalification Training Program IR 05000443/19920241993-02-0404 February 1993 Insp Rept 50-443/92-24 on 921222-930125.Major Areas Inspected:Operations,Radiological Controls,Emergency Preparedness,Maint/Surveillance,Security,Engineering/ Technical Support & Safety Assessment/Quality Verification IR 05000443/19930011993-01-25025 January 1993 Insp Rept 50-443/93-01 on 930103-20.Licensee Assessment of Event Thorough & Well Documented.Major Areas Inspected: Events Leading Up to Loss of Both Main Feedwater Pumps & Subsequent Manual Trip of Reactor IR 05000443/19920271993-01-12012 January 1993 Insp Rept 50-443/92-27 on 921117-1221.No Violations Noted. Major Areas Inspected:Conducted Daily CR Tours,Observed Shift Turnovers,Attended Morning Station Managers Meeting, EDG Rooms & Condensate Storage Tank Bldg IR 05000443/19920261992-12-22022 December 1992 Insp Rept 50-443/92-26 on 921023-30.No Violations Noted. Major Areas Inspected:Review of Cilrt & LLRT Procedures, Witness Cilrt & LLRT Test & Review Cilrt & LLRT Test Results IR 05000443/19920251992-12-0101 December 1992 Insp Rept 50-443/92-25 on 921013-1116.Violations Noted. Major Areas Inspected:Summary of Activities,Radiation Controls,Security,Ep & Plant Operations IR 05000443/19920221992-11-27027 November 1992 Insp Rept 50-443/92-22 on 921005-09.One non-cited Violation Noted.Major Areas Inspected:Radiological Controls Program, Predominately Involving Observation of Field Activities During 1992 Refueling Outage & Review of HP Program IR 05000443/19900221990-10-26026 October 1990 Insp Rept 50-443/90-22 on 901009-12.No Violations Noted. Major Areas Inspected:Design Implementation Verification & Surveillance Test Procedures IR 05000443/19900171990-10-24024 October 1990 Insp Rept 50-443/90-17 on 900905-1014.Major Areas Inspected: Operations,Radiological Controls,Maint/Surveillance & Security 1999-09-24 Category:UTILITY MONTHYEARIR 05000443/19900161990-09-21021 September 1990
[Table view]Insp Rept 50-443/90-16 on 900730-0904.No Violations Noted. Major Areas Inspected:Operations,Radiological Controls, Maint/Surveillance,Security,Engineering/Technical Support, Safety Assessment & Quality Verification ML20058P7941990-08-15015 August 1990 Insp Rept 50-443/90-15 on 900625-0729.Violations Noted.Major Areas Inspected:Operations,Radiological Controls,Maint/ Surveillance,Emergency Preparedness,Security,Engineering/ Technical Support & Safety Assessment/Quality Verification IR 05000443/19900131990-07-13013 July 1990 Safety Insp Rept 50-443/90-13 on 900521-25.No Violations Noted.Deficiencies Noted.Major Areas Inspected:Licensee Maint & Surveillance Programs & Implementation,Work Package Reviews & Sys Walkdowns IR 05000443/19900121990-07-10010 July 1990 Insp Rept 50-443/90-12 on 900514-0624.No Violations Noted. Major Areas Inspected:Operations,Radiological Controls, Maint/Surveillance,Emergency Preparedness,Security, Engineering & Technical Support & Safety Assessment IR 05000443/19900141990-07-0303 July 1990 Insp Rept 50-443/90-14 on 900618-22.No Violations Noted. Major Areas Inspected:Licensee Action on Previously Identified Findings,Mgt Support,Security Program Plans & Audits,Protected & Vital Area Physical Barriers & Detection IR 05000443/19900811990-06-14014 June 1990 Insp Rept 50-443/90-81 on 900316-0502.No Violations or Unresolved Items Noted.Major Areas Inspected:Power Ascension Test Program IR 05000443/19890081989-09-13013 September 1989 Insp Rept 50-443/89-08 on 890701-0817.No Violations Noted. Recurring Weakness Discussed.Major Areas Inspected:Open Items,Security Incident Repts,Reportable Events & Allegations IR 05000443/19890071989-08-16016 August 1989 Insp Rept 50-443/89-07 on 890619-23.No Violations Noted. Major Areas Inspected:Design,Design Changes & Mod ML20246A9461989-08-0808 August 1989 Team Insp Rept 50-443/89-81 on 890612-23.No Violations Noted.Major Areas Inspected:Licensee Implementation of Low Power Startup Test Program,Including Witnessing Precritical Preparations,Approach to Criticality & Startup Testing IR 05000443/19890061989-07-27027 July 1989 Insp Rept 50-443/89-06 on 890527-0630.No Deficiencies Found in Operation of Central Alarm Station.Major Areas Inspected: Plant Operation,Security,Operational Safety & Maint & Surveillance IR 05000443/19890801989-07-0707 July 1989 Readiness Assessment Team Insp Rept 50-443/89-80 on 890527- 0601.No Violations Noted.Major Areas Inspected:Operations, Radiation Protection,Safety Assessment/Quality Verification & Startup Testing IR 05000443/19890051989-06-19019 June 1989 Insp Rept 50-443/89-05 on 890424-0526.No Violations Noted. Major Areas Inspected:Operational Safety,Licensee Reportable Events,Station Info Repts,Maint,Surveillance & Licensee Followup to NRC Info Notices IR 05000443/19890031989-05-24024 May 1989 Insp Rept 50-443/89-03 on 890228-0424.Violation Noted.Major Area Inspected:Operational Safety,Lers,Station Info Repts, Maint,Surveillance,Nrc Info Notices,Previous Items & Followup Issues IR 05000443/19890041989-05-11011 May 1989 Insp Rept 50-443/89-04 on 890327-31.No Violations Noted. Major Areas Inspected:Licensee Activities Re Info Notice 86-053,previously Identified Electrical Items & Program to Maintain Emergency Diesel Generator Fuel Oil ML20248B8841989-03-30030 March 1989 Insp Rept 50-443-89/01 on 890110-0227.No Violations Noted. Major Areas Inspected:Operational Safety,Design Changes & Mods,Licensee Reportable Events & Station Info Repts,Maint, Training & Licensee Actions on Previous Insp Findings IR 05000443/19890021989-02-22022 February 1989 Emergency Preparedness Insp Rept 50-443/89-02 on 890130- 0203.No Deviations Noted.Major Areas Inspected:Licensee Action on Previously Identified Items,Emergency Response Facilities & Equipment & Mgt Control & Organization IR 05000443/19880141988-11-0202 November 1988 Partially Withheld Physical Security Insp Rept 50-443/88-14 on 880926-29 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Mgt Effectiveness,Security Plan & Implementing Procedures,Program Audit & Records & Repts IR 05000443/19880121988-10-20020 October 1988 Insp Rept 50-443/88-12 on 880907-09.No Violations Noted. Major Areas Inspected:Licensee Readiness to Resume Start Up Testing IR 05000443/19880111988-10-0303 October 1988 Insp Rept 50-443/88-11 on 880829-0902.No Violations Noted. Major Areas Inspected:Procedures & Records Re Mods, Engineering & Overall Technical Support.Unresolved Item Re Control & Completion of Designated Mod Work Noted IR 05000443/19880101988-09-28028 September 1988 Insp Rept 50-443/88-10 on 880706-0906.Violations Noted.Major Areas Inspected:Actions on Previous Insp Findings,Nrc Bulletins & Info Notices,Operational Safety,Potential ROs & Operational Events & Maint & Surveillance Activities IR 05000443/19880071988-07-29029 July 1988 Insp Rept 50-443/88-07 on 880524-0705.No Violations Noted. Major Areas Inspected:Routine Plant Operations,Maint & Surveillance Activities,Physical Security & Licensee Potentially Reportable Occurrences & Operational Events IR 05000443/19880091988-07-0606 July 1988 Insp Rept 50-443/88-09 on 880627-29.No Violations Noted. Major Areas Inspected:Emergency Preparedness & Observation of Licensee Annual full-participation Emergency Exercise IR 05000443/19880081988-06-22022 June 1988 Insp Rept 50-443/88-08 on 880601-02.No Violations Noted. Major Areas Inspected:Util Vehicular Alert & Notification Sys to Be Utilized as Public Alert & Notification Sys for Communities within Commonwealth of Ma IR 05000443/19880061988-06-15015 June 1988 Insp Rept 50-443/88-06 on 880329-0523.No Violations Noted. Major Areas Inspected:Actions on Previous Insp Findings, Routine Plant Operations,Physical Security,Licensee Potentially ROs & Operational Events & Maint Activities IR 05000443/19880041988-04-15015 April 1988 Insp Rept 50-443/88-04 on 880222-26.No Violations Noted. Major Areas Inspected:Review of Licensee Startup/Power Ascension Test Program,Vendor Recommended Reactor Trip Breaker (DS-416) Mods & Qa/Qc Interfaces IR 05000443/19880051988-04-11011 April 1988 Physical Security Insp Rept 50-443/88-05 on 880229-0304.No Violations Noted.Major Areas Inspected:Security Event Repts, NRC Bulletins,Circulars & Notices,Mgt Effectiveness, Organization,Program Audit,Physical Barriers & Lighting IR 05000443/19880021988-04-0606 April 1988 Safety Insp Rept 50-443/88-02 on 880202-0328.No Violations Noted.Major Areas Inspected:Operational Safety,Licensee Action on Previous Insp Findings,Nrc Bulletins,Info Notices & Generic Ltr,Lers & Svc Water Sys Corrosion IR 05000443/19880031988-03-29029 March 1988 Insp Rept 50-443/88-03 on 880216-19.No Violations Noted. Major Areas Inspected:Action on Previously Identified Items, Emergency Response Facilities & Equipment,Audits & Reviews, Training,Drills & Exercises IR 05000443/19870261988-03-0202 March 1988 Safety Insp Rept 50-443/87-26 on 871208-880201.No Violations Noted.Major Areas Inspected:Operational Safety,Licensee Action on Previous Insp Findings,Followup Issues,Usi A-26, Allegation Followup & Control Room Ventilation IR 05000443/19870251987-12-22022 December 1987 Emergency Preparedness Insp Rept 50-443/87-25 on 871215-17. No Violations Noted.Major Areas Inspected:Licensee Annual Emergency Exercise Performed on 871215 IR 05000443/19870231987-11-10010 November 1987 Insp Rept 50-443/87-23 on 870909-1019.No Violations Noted. Major Areas Inspected:Work Activities,Procedures & Records Re Startup Testing & License Issuance,Surveillance,Maint & Plant Operations During Cold Shutdown Condition IR 05000443/19870211987-10-29029 October 1987 Partially Withheld Physical Security Insp Rept 50-443/87-21 on 870817-21 (Ref 10CFR2.790 & 73.21).No Noncompliance Noted.Major Areas Inspected:Records & Repts,Testing & Maint, Physical Barriers,Lighting & Compensatory Measures IR 05000443/19870161987-10-21021 October 1987 Insp Rept 50-443/87-16 on 870707-0908.One Violation Noted. Major Areas Inspected:Work Activities,Procedures,Records Re Design Control,Mods,Testing,Maint,Surveillance,Training & Plant Operations During Cold Shutdown IR 05000443/19870221987-09-24024 September 1987 Insp Rept 50-443/87-22 on 870819-21.No Violations Noted. Major Areas Inspected:Adequacy of Licensee Actions to Correct Notice of Violation Issued for Failing to Notify Both States of Ma & Nh During Unusual Event on 870211 IR 05000443/19870201987-08-11011 August 1987 Insp Rept 50-443/87-20 on 870720-24.Violation Noted.Major Areas Inspected:Administrative Controls for Safety Tagging of Sys & Components,Control of Temporary Mods & QA Interfaces W/Operations & Engineering IR 05000443/19870071987-08-0404 August 1987 Insp Rept 50-443/87-07 on 870406-10,20-24 & 0504-08.No Violations Noted.Major Areas Inspected:Technical Issues & New Allegations Raised by Employee Legal Project in 870209 & 0402 Ltrs & Info Provided During 870420 Interview IR 05000443/19870151987-08-0303 August 1987 Insp Rept 50-443/87-15 on 870623-26.No Violations Noted. Major Areas Inspected:Nonradiological Chemistry Program, Including Analytical Procedure Evaluations & Measurement Control IR 05000443/19870131987-07-23023 July 1987 Insp Rept 50-443/87-13 on 870505-0706.Violations Noted.Major Areas Inspected:Work Activities,Procedures & Records Relative to Design Control,Mods & Testing.Quality of Evaluation of LERs During Period Apr 1986-Apr 1987 Encl IR 05000443/19870141987-06-29029 June 1987 Insp Rept 50-443/87-14 on 870602-05.No Violations Noted. Major Areas Inspected:Status of Occupational Radiological Controls Program,Including Organization & Mgt Control & Training & Qualification IR 05000443/19870101987-05-28028 May 1987 Insp Rept 50-443/87-10 on 870310-0504.No Violations Noted. Major Areas Inspected:Work Activities,Procedures & Records Relative to Startup Testing.One Unresolved Item Re Need for Followup of Positioning of RHR Crossover Line Valves Noted IR 05000443/19870011987-05-0505 May 1987 Insp Rept 50-443/87-01 on 870112-16,0209-13 & 24-27.No Violations Noted.Major Areas Inspected:Preoperational Test Program,Including Review of Preoperational Test Procedures. Table of Corrective Actions for Testing Encl IR 05000443/19870111987-04-10010 April 1987 Insp Rept 50-443/87-11 on 870316-20.No Violations Noted. Major Areas Inspected:Startup Test Program review,post-core Hot Functional Test Witnessing & Test Result Review IR 05000443/19870021987-04-0909 April 1987 Insp Rept 50-443/87-02 on 870103-0309.Violations Noted: Problem W/Implementation of Design Control Program Re Control of Bldg Makeup Air Subsystem.Unresolved Item Re 1E Inverter Identified for Future Followup IR 05000443/19870091987-03-31031 March 1987 Insp Rept 50-443/87-09 on 870302-06.No Violations Noted. Major Areas Inspected:Post Core Load Hot Functional Testing Activities,Including Emergency Feedwater Turbine Drive Testing,Procedure Changes & Independent Measurements IR 05000443/19870121987-03-29029 March 1987 Insp Rept 50-443/87-12 on 870317-19.No Violations Noted. Major Areas Inspected:Changes to Emergency Preparedness Program,Licensee Reviews/Audits,Organization & Mgt Control & Security/Emergency Preparedness Program Interface IR 05000443/19870051987-03-20020 March 1987 Insp Rept 50-443/87-05 on 870217-24.No Violations Noted. Major Areas Inspected:Startup Test Program review,post-core Hot Functional Test Witnessing & Test Result Review IR 05000443/19870031987-03-10010 March 1987 Insp Rept 50-443/87-03 on 870127-30 & 0209-13.No Violations Identified.Major Areas Inspected:Surveillance Testing Program of Instrumentation & Control Dept & Operations Dept & Licensee Actions on Previous Insp Findings IR 05000443/19870081987-03-10010 March 1987 Insp Rept 50-443/87-08 on 870219-20.Violations Noted:Failure to Follow Requirements of Emergency Procedure Er 1.0, Classification & Notification of Emergencies at Zero Power IR 05000443/19860541987-01-29029 January 1987 Partially Withheld Insp Rept 50-443/86-54 on 861111-870102 (Ref 10CFR73.21).Deviations Noted:Design for Control Room Makeup Ventilation Sys Did Not Provide for Maintaining Positive Pressure within Control Room Complex IR 05000443/19860581987-01-21021 January 1987 Insp Rept 50-443/86-58 on 861208-12.No Violation Noted. Major Areas Inspected:Generic Ltr 83-28 Concerns Re Vendor Interface & post-maint Testing.Unresolved Item Identified Re Spare Parts for Class 1E Automatic Shunt Trip Relays 1990-09-21 Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS MONTHYEARIR 05000443/19990101999-09-24024 September 1999
[Table view]Insp Rept 50-443/99-10 on 990726-30 & 0809-13.No Violations Noted.Major Areas Inspected:Corrective Action Program IR 05000443/19990051999-08-25025 August 1999 Insp Rept 50-443/99-05 on 990621-0801.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support ML20210P3251999-08-0303 August 1999 Notice of Violation from Insp on 980129-0527.Violation Noted:On 990116,Willimas Power Corp (Wpc),Contractor for Naesco,Discriminated Against Wpc Electrician Due to Employee Involvement in Protected Activity ML20210N5781999-08-0303 August 1999 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $55,000.Violation Noted:On 980116,licensee Contractor Discriminated Against Contractor Electrician Due to Employee Involvement in Protected Activity ML20210P3431999-08-0303 August 1999 Notice of Violation from Insp on 990129-0527.Violation Noted:On 980116,G Pageau Engaged in Deliberate Misconduct That Caused Naesco to Be in Violation of 10CFR50.7 ML20211A7351999-07-29029 July 1999 EN-99-029:on 990803,notice of Proposed Imposition of Civil Penalty in Amount of $55,000 Issued to Licensee.Based on Severity Level III Violation Involving Licensee Contractor That Discriminated Against Contractor Electrician IR 05000443/19990061999-07-26026 July 1999 Insp Rept 50-443/99-06 on 990510-0620.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support,Including Security Controls ML20196E0261999-06-21021 June 1999 Insp Rept 50-443/99-01 on 990321-0509.Violations Noted. Major Areas Inspected:Aspects of Licensee Operations,Maint, Engineering & Plant Support IR 05000443/19990031999-05-20020 May 1999 Insp Rept 50-443/99-03 on 990308-0408.Non-cited Violations Noted.Major Areas Inspected:Licensee Engineering Activities Which Included in-depth Review of PCCW Sys IR 05000443/19990011999-04-20020 April 1999 Insp Rept 50-443/99-01 on 990207-0321.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000443/19980111999-02-26026 February 1999 Insp Rept 50-443/98-11 on 981228-990207.No Violations Noted.Major Areas Inspected:Licensee Operations,Engineering, Maint & Plant Support IR 05000443/19980101999-01-28028 January 1999 Insp Rept 50-443/98-10 on 981115-1227.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000443/19980091998-12-11011 December 1998 Insp Rept 50-443/98-09 on 981004-1114.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support ML20198C1441998-12-11011 December 1998 Notice of Violation from Insp on 981004-1114.Violation Noted:On 981113, a Service Water & a Cooling Tower SWS Removed from Service to Conduct Planned Maint on SWS Valve & Applicable TS Action Statement Not Identified & Tracked IR 05000443/19983011998-11-25025 November 1998 NRC Operator Licensing Exam Rept 50-443/98-301 (Including Completed & Graded Tests) for Tests Administered on 981016- 981016-23.All Five SRO & All Four RO Applicants Passed All Portions of Exam PNO-I-98-051, on 981112,licensee Shutdown Seabrook Station, After Visual Insp Indicated Damage to Main Generator a Phase Output bus.One-week Outage Planned to Troubleshoot & Repair Bus Ductwork.Licensee Did Not Issue Press Release1998-11-13013 November 1998 PNO-I-98-051:on 981112,licensee Shutdown Seabrook Station, After Visual Insp Indicated Damage to Main Generator a Phase Output bus.One-week Outage Planned to Troubleshoot & Repair Bus Ductwork.Licensee Did Not Issue Press Release IR 05000443/19980061998-11-0606 November 1998 Insp Rept 50-443/98-06 on 980823-1003.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000443/19980081998-10-16016 October 1998 Insp Rept 50-443/98-08 on 980921-25.No Violations Noted. Major Areas Inspected:Long Term MOV Program Under GL 89-10 Program at Seabrook Station & Will Review long-term MOV Program Under GL 96-05 IR 05000443/19980071998-10-0202 October 1998 Errata to Insp Rept 50-443/98-07 on 980803-07,including Coversheet & Executive Summary Pages ML20154B1681998-09-28028 September 1998 Insp Rept 50-443/98-09 on 980803-07.Violations Noted.Major Areas inspected:medium-voltage & low-voltage Power Circuit Breakers IR 05000443/19980051998-09-25025 September 1998 Insp Rept 50-443/98-05 on 980705-0822.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support Re Licensee Security Facilities & Equipment in Areas of Protective Area Assessment Aids IR 05000443/19980041998-07-30030 July 1998 Insp Rept 50-443/98-04 on 980517-0704.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support ML20236W2411998-07-30030 July 1998 Notice of Violation from Insp on 980517-0704.Violation Noted:On 980504,licensee Did Not Take Action to Promptly Identify Whether Steam Pressure Protection Channels for a & D Steam Generators Operable,After Three Found Inoperable IR 05000443/19980031998-07-0909 July 1998 Insp Rept 50-443/98-03 on 980602-04.No Violations Noted. Major Areas Inspected:Insp Observed & Evaluated Licensee Biennial full-participation Exercise in Simulator Control Room,Technical Support Ctr & Operations Support Ctr PNO-I-98-022, on 980611,Seabrook Station Commenced Plant Shutdown After Declaring Control Bldg Air Conditioning Sys Inoperable.Licensee Evaluating Problems Associated W/Air Conditioning Sys.State of Nh Has Been Notified1998-06-12012 June 1998 PNO-I-98-022:on 980611,Seabrook Station Commenced Plant Shutdown After Declaring Control Bldg Air Conditioning Sys Inoperable.Licensee Evaluating Problems Associated W/Air Conditioning Sys.State of Nh Has Been Notified IR 05000443/19980021998-06-12012 June 1998 Insp Rept 50-443/98-02 on 980329-0516.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maint & Plant Support ML20217L8231998-04-27027 April 1998 Notice of Violation from Insp on 980201-0328.Violation Noted:On 980313,inspector Identified That Four Individuals Performing Work Inside Posted Contaminated Area Failed to Comply W/Radiation Work Permits & Posted Instructions ML20217L8311998-04-27027 April 1998 Insp Rept 50-443/98-01 on 980201-0328.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support ML20217L0631998-04-0101 April 1998 Notice of Violation from Insp on 971207-980131.Violation Noted:Measures Not Established to Assure That Significant Conditions Adverse to Quality Promptly Identified & Corrected ML20216B1271998-02-27027 February 1998 Insp Rept 50-443/97-08 on 971212-980131.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000443/19970091998-02-20020 February 1998 Insp Rept 50-443/97-09 on 971215-18 & 980120-21.Violations Noted.Major Areas Inspected:Maint ML20203E4091998-02-20020 February 1998 Notice of Violation from Insp on 971215-18 & 980120-21. Violations Noted:On 970313,licensee Changed Procedures as Described in UFSAR & Failed to Perform Written SE to Determine That Change Did Not Involve USQ IR 05000443/19970991998-01-23023 January 1998 SALP Rept 50-443/97-99 for 960505-971206 IR 05000443/19970071998-01-0707 January 1998 Insp Rept 50-443/97-07 on 971005-1206.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maint & Plant Support Re Implementation of Security Program ML20199L3191997-11-20020 November 1997 Notice of Violation from Insp on 970816-1004.Violation Noted:Mfp Reassembled & Tested W/O Terminating Lead (D4) Defeating Electrical Trip Capability of MFP IR 05000443/19970061997-11-20020 November 1997 Insp Rept 50-443/97-06 on 970816-1004.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering, Maint & Plant Support IR 05000443/19970051997-10-27027 October 1997 Insp Rept 50-443/97-05 on 970825-0910.No Violations Noted. Major Areas Inspected:Process of Operating Experience, Trending,Tagging & self-assesment ML20211G0121997-09-23023 September 1997 Insp Rept 50-443 on 970616-0815.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support & Emergency Preparedness Program ML20211G0061997-09-23023 September 1997 NOV from Insp on 970616-0815.Violation Noted:Staff Changed Lineup of Safety Injection Sys Test Header from Primary Drain Tank to Refueling Water Storage Tank W/O Properly Changing Procedure Os 1005.05,Safety Injection Operation ML20210N5811997-08-13013 August 1997 Corrected NOV Consisting of Revised Pages IR 05000443/19970031997-08-13013 August 1997 Corrected Insp Rept 50-443/97-03 Consisting of Changes to Section S1.2.c ML20196J6501997-07-30030 July 1997 Notice of Violation from Insp on 970522.Violation Noted: Vehicle Number Ldv 16-02 Found Unattended W/Keys in Ignition & Running & Not in Control of Authorized Person ML20196J6691997-07-30030 July 1997 Insp Rept 50-443/97-03 on 970415-0615.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20140D1281997-05-30030 May 1997 Insp Rept 50-443/97-02 on 970304-0414.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support ML20140D1241997-05-30030 May 1997 Notice of Violation from Insp on 970304-0414.Violation Noted:On 950305,35 Licensee Designated Vehicles in Use Outside Protected Area for Purposes Other than Servicing, Repairs,Emergencies or Moving Supplies from Warehouse PNO-I-97-025A, on 970426,protest Related to Twentieth Anniversary of Mass Arrest at Seabrook in 1997 Update Made. Forty Protestors Arrested for Trespassing After Climbing owner-controlled Fence1997-04-28028 April 1997 PNO-I-97-025A:on 970426,protest Related to Twentieth Anniversary of Mass Arrest at Seabrook in 1997 Update Made. Forty Protestors Arrested for Trespassing After Climbing owner-controlled Fence PNO-I-97-025, on 970426,Clamshell Alliance Planning Twentieth Anniversary civil-disobedience Rally at Seabrook Site. Licensee Made Special Arrangements to Escort Reporters to Cover Demonstration from Inside Site Boundary Fence1997-04-25025 April 1997 PNO-I-97-025:on 970426,Clamshell Alliance Planning Twentieth Anniversary civil-disobedience Rally at Seabrook Site. Licensee Made Special Arrangements to Escort Reporters to Cover Demonstration from Inside Site Boundary Fence IR 05000443/19970011997-04-0808 April 1997 Insp Rept 50-443/97-01 on 970114-0303.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000443/19960111997-03-0707 March 1997 Insp Rept 50-443/96-11 on 961130-970113.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20133A5351996-12-24024 December 1996 Notice of Violation from Insp on 961001-1129.Violation Noted:On 940127,licensee Implemented Change 1 to Rev 7 to Station Procedure, Startup Feed Pump Operation, That Authorized Sys Configuration During Normal Plant Operation 1999-09-24 |
Inspection Report - Seabrook - 1978013 | |
---|---|
Assessments |
Text
- - - _ - - _ _ _ _ _ _ _ _ _ _ _ - _ - - - _ _ _ _ _ _ - - _ _ - _ . - _ - - - - - - - _ - - - - _ - - _ - _ - - - - - - _ - - -
.
.,
U.S. NUCLEAR REGULATORY COMMISSION Q OFFICE OF INSPECTION AND ENFORCEMENT Region I 50-443/78-13 Report No. 50-444/78-13 50-443 Docket No. 50-444 CPPR-135 A License No. CPPR-136 Priority -- Category A Licensee: Public Service Company of New Hampshire 1000 Elm Street Manchester, New Hampshire Facility Name: Seabrook Station, Units 1 and 2 Inspection at: Seabrook, New Hampshire Inspection conducted: September 5-8, 1978 Inspectors: C T/m b erw , M Seth A. Folsom, Reactor Inspector date signed date signed
,
.
date si ned Approved by: k h l h/i h nsJ hc r 4 ~2I,/ N
, W.' McGaughy,' Chief (@y6jects Section, RC&ES Branch Wate signed '
l Inspection Summary:
inspection on September 5-8, 1978 (Report No. 50-443/78-13)
' Areas Inspected: Routine, unannounced inspection by a regional based inspector of piping contractor's quality assurance program, and installation of containment re-inforcing steel. The inspector performed a construction site tour and reviewed licensee action on previous inspection findings. The inspection involved 20 in-spector-hours onsite by one NRC regional based inspecto Results: No items of noncompliance were identifie Inspection on September 5-8, 1978 (Report No. 50-444/78-13)
Areas inspected: Routine, unannounced inspection by a regional based inspector of piping contractor's quality assurance program. The inspector performed a construction site tour and reviewed licensee action on previous inspection findings. The inspection involved 11 inspector-hours onsite by one NRC regional based inspecto Results: No items of noncompliance were identifie Region I Form 12 7811 ) Q gDcq 4 (Rev. April 77)
L-_ __ _ _ ___-- --- -
-- - - - - - - - - - - - -
_______-___ __-
.
DETAILS 1. Persons Contacted Yankee Atomic Electric Company Mr. D. L. Covill, Quality Assurance Field Engineer, Civil Mr. W. J. Gagnon, Quality Assurance Field Engineer, Mechanical
- Mr. J. H. Herrin, Site Manager
- Mr. W. P. Johnson, Vice President Mr. G. Mcdonald, Quality Assurance Engineer (Westborough)
Mr. R. P. Pizzuti, Construction Manager
- Mr. T. M. Sherry, Director of Construction
- Mr. J. W. Singleton, Field Quality Assurance Manager Mr. A. J. Stewart, Site Geologist Perini Power Constructors Mr. R. A. Brasells, Carpenter Superintendent Mr. P. Antonich, Assistant Superintendent Quality Assurance United Engineers and Constructors Mr. M. A. Edgar, Resident Construction Engineer Mr. G. B. Frey, Project Superintendent Operations Mr. B. F. McCoy, Security Supervisor Mr. R. N. Moyer, Field Superintendent Quality Assurance / Quality Control Mr. D. R. Rhyne, Lead Startup and Test Engineer
- Mr. T. P. Vasallo, Jr. , Quality Assurance Engineer Mr. J. P. Zabielski, Concrete Superintendent Royal Globe Insurance Companies
- Mr. J. R. Boyd, Inspection Specialist
- Mr. C. O'Sullivan, Authorized Nuclear Inspector j Pullman /Higgins (Piping)
- Mr. R. G. Davis, Field Quality Assurance Manager Mr. D. R. Jones, Quality Assurance Controller
- Mr. J. P. Rowley, Resident Construction Manager Pittsburgh Des Moines Mr. J. Hill, Site Construction Superintendent Mr. W. Stiger, Site Quality Assurance Superintendent
___
t
_ . _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
.
The inspector also interviewed other licensee and contractor employees including craft personnel, supervisors, and QC inspectors during this inspectio * denotes those present at the exit intervie . Plant Tour The inspector conducted a walk-through inspection of the construction site and observed completed work, and work in progress. The areas observed for Unit 1 were containment building base mat, reactor pit liner,' auxiliary building reinforcing steel, and concrete curing and placement In Unit 2, dewatering, containment building re-inforcing steel installation and cooling tower s+ructural sla The inspector examined construction operations for compliance with regulatory requirements and licensee commitments. Specific activities observed by the inspector in both units included preparation for concrete placements, form stripping, excavating, backfilling, soil compaction, grinding, welding, and pressure testin No items of noncompliance were identifie . Licensee Action on Previous Inspection Findings (Closed) Unresolved Item (443/77-03-01 and 444/77-03-01): Licensee review of NRC Circulars 77-01, 77-05, and 77-06. These Circulars had not originally been sent by YAEC to UE&C for action, but this has since been done. The inspector has reviewed the licensee's actions relating to these Circulars (Inspection Reports 50-443/78-08 and 50-444/78-08), and found them to be acceptabl The inspector had no further questions on this matte (Closed) Unresolved Item (Reference: Inspection Reports 50-443/76-02, Paragraph 6; and 50-444/76-02, Paragraph 6) PSAR amendment for control of specification The PSAR revision to correct this condition was issued on January 21, 1977. The inspector had no further questions on this matte . Quality Assurance Program - Pullman Power Products Company The installation of all piping at Seabrook Units 1 and 2 will be performed by Pullman /Higgins, a joint venture of the Pullman Power Products Company and J. C. Higgins Compan Installation of safety-related piping is scheduled to start in October,1978. The inspector
l
.
l
) reviewed the Quality Assurance Manual, and related construction and i quality control procedures, for conformance to regulatory require-
,
ments and licensee PSAR commitments. Key production and quality assurance personnel were also interviewed to ascertain their under-i
'
standing of the QA Manual requirements. The inspector attended the presentation of a 60-minute Pullman /Higgins video tape training session used for indoctrination and training of newly-hired personne Documentation reviewed during the inspection included:
(1) Pullman Power Products QA Manual, Issue 3, May 10,1978, with Supplement 1, August 17, 1978. This manual " document the quality system in effect for those activities defined with the scope of ASME Certificate of Authoriza'; ion Nos. N-1101 (NPT) and N-1102 (NA)."
(2) Pullman Power Products Field Inspection Procedures
--
Final Inspection, X-4, July 13,1978
--
Field Receiving Inspection X-5, April 14,1978
--
Calibration of Tools, Measurement and Test Equipment, XII-2, July 18,1978
--
Field Storage, XII-S, July 13, 1978
--
Field Handling of Materials and Equipment XIII-9, February 6, 1978
--
Field Leak Testing - Hyd,'ostatic and Pneumatic, XI-1, July 21, 1978
--
Standard Method of Protecting Ends of Fabricated Pipe for Nuclear Service XIII-11, July 13,1978
--
Reporting of Defects and Noncompliaces to the NRC, XIII-12, July 14, 1978 No items of noncompliance were identifie _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _
. .,
5. Testing of Coarse and Fine Aqqregate The inspector reviewed the testing of coarse and fine aggregate for conformance to ASTM C-33, and to VE&C Specification 5-1, February 24, 1975. Aggregate samples' were being tested for gradation, moisture, fines, organic matter, flat and elongated, friable, light-weight, soft fragments, specific gravity, absorption, soundness, potential reactivity and LA abrasio Pittsburgh Testing Laboratory Reports; for examples, Lab. No. 992 August 31, 1978 and Lab No. 987, August 31, 1978 were examined and the sampling schedule and test results confirmed that required sampling frequencies were being maintained, and that the aggregate met the specification requirement . Exit Interview The inspector met with the licensee and contractor representatives (denoted in Paragraph 1) at the conclusion of the inspection on September 8, 197 The inspector summarized the scope and findings of the inspection.