MEMORANDUM FOR:

Oscar DeMiranda. Senior Allegation Coordinator Enforcement and Investigation Coordination Staff FROM:

Kerry D. Landis, Chief

-

Reactor Projects Branch 3

//

-

Division of Reactor Projects SUBJECT:

RII-96-A-0129 - A MAINTENANCE MANAGER WAS UNPROFFSSIONAL AND VIOLATED THE FREEZE SEAL PROCEDURE. AND A NEW V.P. DOES NOT CONSIDER ALARA CONCERN BECAUSE OF HIS STRINGENT HOUSEKEEPIN PRACTICE.

The Division of Reactor Pro of this anonymous concern. jects performed.a review and independent inspection Our inspection regarding this matter has been completed and our findings are documented in the enclosures to this memorandum.

Enclosure 1 is the Allegation Evaluation Report which summarizes the findings, and the inspection results are documented in Enclosure 2. NRC Inspection Report No. 50-335.389/96-11. paragraphs M2.1, and M3.1.

Based on the information provided. we were able-to partially substantiate the allegation.

One non-cited violation of regulatory requirements was 1dentifjed.

This concludes the staff's, activities regarding this matter This allegation is considered. closed.

1f you have any questions. please contact me.~

Enclosures:

1. Allegation Evaluation Report 2. Inspection Report No.

50-335.389/96-11 I

.

.

N

.

9703130209 970306 PDR FOIA

'

BINDER 96-485, PDR m

,__

.

.

.

.

_

.

.-

. _.

.

,

d

- r

{

-

ENCLOSURE 1 ALLEGATION EVALUATION REPORT ALLEGATION RII 96 A 0129

,

A HAINTENANCE MANAGER WAS UNPROFESSIONAL AND VIOLATED THE FREEZE SEAL PROCEDURE. AND A NEW V.P. DOES NOT CONSIDER ALARA CONCERN BECAUSE OF HIS STRINGENT HOUSEKEEPING PRACTICE.

ST'LUCIE NUCLEAR PLANT

-

DOCKET NOS. 50 335 AND 50 389

.

CONCERNS:

'

A maintenance manager was unprofessional and he shut down all jobs in the pipe

'

. tunnel on May 22. 1996.

As result. no one was left to implement contingency

plan in the event of problem with freeze plug.

This was a violation of the i

freeze seal procedure.

A new V.P. does not consider ALARA concern from the standpoint that people will spend more time at work and cleaning-up at the expense of receiving more dose because of his stringent housekeeping practice.

OISCUSSION:

'

,

The inspector reviewed GMP-10. revision 6. " Application Of Freeze Seals." and several work orders completed during the recent Unit I refueling outage in'olving the use of freeze seals.

v

,

The inspector found that the procedure contained appropriate guidance to preclude challenges to the plant associated with the use of freeze seals.

Documentation reviews of the following work orders were completed as

.

delineated below.

All the packages contained the required documentation including implantation plans, contingency plans, inspection reports. and temperature monitoring logs.

Exceptions are as noted below:

~

e Work Order 96008441 installed a freeze seal on a six inch SI system header.

The temperature monitoring log had been maintained ~ as suggested in the procedure: however, the inspector noted two periods of time on May 22 in which the readings were not documented.

In one case a reading suggested to be taken every twenty minutes was not

recorded and in another case the reading was taken every thirty minutes.

e Work Order 96005107 installed a freeze seal on another six inch SI

.

system header.

The temperature monitoring log had been maintained l

.

as suggested in the procedure, however, the inspector noted for a period of one hour'on May 22 that no readings were documented..

e Work Order 96008029 installed a freeze seal on a twelve inch SI system line.

.

e Work Order 96005109 installed a freeze seal on a six inch SI system

'

' header.

.

.

9

..

'

-

e Work Order 96011512 installed a freeze seal on a 3/4 inch RCS instrumentation line.

The inspector' discussed the cases involving readings not logged with a maintenance supervisor involved with freeze seal usage.

He stated that

' recording the readings every twenty minutes is a guide and not a strict -

procedural requirement. He further stated that the freeze seals were never left unattended and the readings were probably not recorded simply because the freeze seal attendant forgot to do so.

Discussion with licensee management indicated that for a short period of time.

~

approximately one hour, work had been stopped to clean the area of trash and unnecessary equipment.

Although the freeze seal personnel were not located directly at the freeze seal they were in the area to fulfill contingency requirements, if necessary.

However. after further discussion with the Maintenance Manager, the inspector concluded that, although the freeze seal monitor was in the area he was not actively monitoring the seal as evidenced

.by the absence of freeze seal temperature data for the time in question.

.However, this failure constitutes a violation of minor significance and is being treated as a Non-Cited Violation. consistent with Section IV of the NRC Enforcement Policy (NCV 335/96-11-03. " Failure To Properly Monitor Freeze Seal") The inspector reviewed the control room logs and noted that there were no log entries which would indicate that the freeze seals were left unattended.

In aodition. the inspector verified that the thaw time of each of these seals would have been on the order of two to three hours and therefore concluded that'the safety impact was minimal.

While observing Maintenance personnel disassemble the V2167, the inspector noted that the tools and equipment needed to support the job had been laid out and arranged on tne floor.

This was discussed with the personnel performing the task who stated that this was to aid in identification while performing the work and wa.s a new management initiative to improve job performance.

The inspector discussed this with the Maintenance Manager who concurred and stated that this practice along with generally maintaining a clean work area. being prepared to do the work prior.to starting, etc.. would decrease rework and ultimately improve efficiency.

The inspector also discussed this with the Health Physics suoervisor who stated that, with the efficiency increases, overall dose expended in maintenance was expected to drop.

The inspector concluded that these efforts were prudent and that benefit could be attained from them.

CONCLUSIONS:

-The inspector was able to determine that a maintenance manager did shut down all jobs in the pice tunnel on May 22. 1996.

The inspector concluded that the concern was partially substantiated in.that the person monitoring the freeze-seal was in the area, but he was not actively monitoring the seal as evidenced by the absence of freeze seal temperature data for the time in question.

As a

-

result. while people were available to implement a contingency plan in the event of_ problem with the freeze plug.- for a time the freeze seal temperature was not being monitored. -The inspector determined that this was a violation of the licensee's crocedure.which requires that at no time shall a freeze seal

.be;left unattended for any reason until the system or component is restored or

.

the Contingency Plan is, implemented.

This failure constitutes a violation of

.

I

.

/

minor significance and is being treated as a Non-Cited Violation, consistent-with Section IV of the NRC Enforcement Policy (NCV 335/96-11-03. " Failure To Properly Monitor Freeze Seal").

The inspectors review of the freeze seals applied during the recent Unit 1 outage indicated that procedural requirements had not been met in one case, t

The inspector was not able to substantiate that the new vice president does not consider ALARA concern from the standpoint that people will spend more time at work and cleaning-up at the expense of receiving more dose because of his stringent housekeeping practice.

The inspector concluded that the efforts to organize the tools and equipment needed to support the job, which were laid out and arranged on the floor, were prudent and that benefit could be attained from them in terms of less rework and dose reduction.

'

This allegation is considered closed.

.

d i

,

.

I

4

--.

- - - -..

- -

- -

- - - -

.

A

.

y

-

WEEKLY BRANCH CHIEF STATUS REPORT.

iBRANCH 3 SIGNATURE ' Kerry D. Landis DATE 9/20/96 PLANT' ISSUES / EVENTS:

a)z St Lucie - Both units.are operating at 100%. A manatee was-found in the intake and was' returned to the river.

b)

Crystal River - The unit is shutdown while repairing a turbine lubricating oil system leak and reenforcing reactor building sump screens. There was an apparent' tampering event associated with the "A" EDG. See attached PN and press release.

c)

' Turkey, Point - Both units are operating at 100%.

,

SIGNIFICANT INSPECTION FINDINGS / INITIATIVES:

a).

Crystal River.- Failure to perform an adequate 10 CFR 50.59 evaluation on diesel generator loading following a modification to remove the automatic-start of the turbine-driven auxiliary feedwater pump.

b)

St. Lucie -

The Maintenance Rule Inspection was conducted during the week. Three violations were. identified. The violations identified were in the areas of (1) program design issues: (2) system scoping issues: and (3)

procedure implementation.

The residents are continuing to inspect a drop control rod event in which the licensee installed the wrong control card as part of the corrective action.

The residents are also inspecting labeling problems and the independent verification process following the bypassing of an incorrect bistable.

NRC-PERSONNEL ISSUES / STATUS:

a)

Son Ninh was approved for transfer from NRR to RII as a project engineer

,

for Branch 3 assigned to FPL.

The' transfer date is September 29, 1996.

,

Son is in Region 11 this week assisting the PE.

b)

Credit Hours authorizedi None

- ISSUES / ACTIVITIES EXPECTED NEXT WEEK:

Crystal-River -

The resident inspectors and two regional inspectors will continue looking into the apparent tampering event.

.

S

..

.

.

.

.

WEEKLY BRANCH CHIEF STATUS REPORT BRANCH 3 SIGNATURE Kerry D. Landis DATE 9/26/96 PLANT ISSUES / EVENTS:

a)

St Lucie - Both units are operating at 100%.

b)

Crystal River - The unit remains shutdown pending a licerise amendment to resolve several US0s on EDG loading.

FPC plans to submit a request for license amendment on 9/27/96.

Repairs were completed for the turbine lubricating oil system leak and reenforcing the reactor building sump screens.

The turbine lubricating

,

oil pipe ruptured due to hydrogen detonation.

The hydrogen is entrained in the oil from interfacing with the hydrogen cooling system and collected in the high point where the rupture occurred. The check valve appears to have provided the spark for the detonation.

Leakoff holes have been drilled in the top of the lube oil pipe to preclude the collection of hy,drogen.

The apparent tampering event associated with the "A" EDG is still under investigation by the licensee, c)

Turkey Point - Unit 4 is operating at 100%.

Unit 3 is in mode 2 continuing the startup following repair to of rod control circuit cards which led to two control rods dropping (see the attached event report)

SIGNIFICANT INSPECTION FINDINGS / INITIATIVES:

a)

Crystal River - Failure to perform an adequate 10 CFR 50.59 evaluation on diesel generator loading following a modification to remove the automatic start of the turbine driven auxiliary feedwater pump.

b)

St. Lucie -

The Maintenance. Rule Inspection was conducted lest week.

Three violations were identified.

The violations identified were in the areas of (1) program design issues: (2) system scoping issues: and (3~)

procedure 1molementation.

An enforcement panel is planned next week.

NRC PERSONNEL ISSUES / STATUS:

a)

Son Ninh was approved for transfer from NRR to RII as a project engineer for Branch 3 assigned to FPL.

The transfer ~date is September 29. 1996.

b)

Credit Hours authorized: None ISSUES /ACTIVITIE$ EXPECTED NEXT WEEK:

Crystal River -

The resident inspectors and~ two regional inspectors will continue looking into the apparent tampering event.

.

.

.

N

.

WEEKLY BRANCH CHIEF STATUS REPORT BRANCH 3 SIGNATURE Kerry D. Landis DATE-10/03/96 PLANT ISSUES / EVENTS:

a)

St Lucie - Both units are operating at 100%.

'

b)

Turkey Point - Both units are operating at 100%.

c)

Crystal River - The unit remains shutdown pending a license. amendment to resolve several US0s on EDG loading and Emergency Feedwater (EFW)

susceptibility to single failure.

FPC plans to submit a remain shutdown for another four to six ' weeks to resolve the design issues and submit the necessary license amendments.

The investigation by the licensee into the apparent tampering 5 vent associated with the "A" EDG was completed on 10/03/96 and the licensee has secured from the security alert.

Billy Crowley will review the report on 10/7/96 and conduct a public exit on 10/9/96 at 9:00 am.

SIGNIFICANT INSPECTION FINDINGS / INITIATIVES:

a)

Crystal River - Failure to perform ari adequate 10 CFR 50.59 evaluation on diesel generator loading following a modification to remove the automatic start of.the turbine driven auxiliary feedwater pump.

b)

Crystal River - Emergency Feedwater (EFW) susceptibility to single failure: during LOOP a failure of one fuse could cause an EFW flow control valve to fail-open allowing one EFW pump to go to runout.

Since both EFW l

pumps draw suction through the same pipe, the resulting flowrate would cause cavitation and failure of both EFW pumps.

b)

St. Lucie -

The Maintenance Rule Inspection identified three potential violations which will be reviewed for an enforcement panel on 10/7/96.

The violations were in the areas of (1) program design issues: (2) system scoping issues:'and (3) procedure implementLtion.

NRC PERSONNEL ISSUES / STATUS:

a ).

Son Ninh started as a project engineer for Branch 3 assigned to FPL.

i b)

Credit Hours authorized: None ISSUES / ACTIVITIES EXPECTED NEXT WEEK:

Crystal River: -

Regional inspection into the apparent tampering event.

.

-

Regional inspection into the Corrective Action Program

-

Maintenance Observation Inspection

-

Management Meeting on Engineering Performance St Lucie - Regional allegation inspection on Emergency Preparedness Program

- Regional Inspection into the Nuclear Instrumentation design control issue which resulted in thr.ee inoperable NI channels during startup

%

i

-

.

WEEKLY BRANCH CHIEF STATUS REPORT BRANCH 3 SIGNATURE Kerry D. Landis DATE 10/17/96

.

PLANT ISSUES / EVENTS:

a)

S.t Lucie - Unit 2 operated at 100% for the entire week. Unit 1 operated at 100% power until 10/17/96, then reduced power to 78% to repair a main condenser water box.

b)

Turkey Point - Both units are operating at 100%.

Unit 3 completed its power uprate from 2200 to 2300 MWth on 10/11.

Unit 4 uprate is scheduled for next week.

Region 11 is monitoring the progress of hurricane Lili and the licensee's preparations for the hurricane (see attached PN).

c)

Crystal River - The unit remains shutdown pending a license amendment.to resolve several US0s on EDG loading and EFW susceptibility to single failure.

FPC plans to remain shutdown for another two months or more to resolve the design issues and submit the necessary license amendments.

Emergency Preparedness Exercise was conducted on. 10/16/96. no major deficiencies were identified.

SIGNIFICANT INSPECTION FINDINGS / INITIATIVES:

a)

Crystal River - Failure to perform an adequate 10 CFR 50.59 evaluation on diesel generator loading following a modification to remove the automatic start of the turbine driven auxiliary feedwater pump.

b)

Crystal River - EFW susceptibility to single failure: during LOOP a failure of one fuse could cause an EFW flow control valve to fall open allowing one EFW pump to go to runout.

Since both EFN pumps draw suction through the same pipe the resulting flowrate would cause cavitation and failure of both EFW pumps.

b)-

St. Lucie -

The Maintenance Rule Inspection identified three potential violations which will be reviewed for an enforcement panel on 10/7/96. The violations were in the areas of (1) program ' design issues: (2) system scoping issues:.and (3) procedure implementation.

All were considered to be SL 4 violations NRC PERSONNEL ISSUES / STATUS:

a)

Credit Hours authorized: None ISSUES / ACTIVITIES EXPECTED NEXT WEEK:

Crystal River: - Operator Requal inspection

-

10/26 Enforcement Action

.

- Cahlil at CR-3 for SRI turnover St Luc.ie

- Regional Inspection into the Nuclear Instrumentation design control issue which resulted in three inoperable NI channels during startup

- Regional Security Inspection

- Engineering Inspection (module 40500)

..

~

i l

b)

St. Lucie -

The Maintenance Rule Inspection identified three potential

]

violations which will be reviewed for an enforcement panel on 10/7/96.

The violations were in the areas of (1) program design issues; (2) system scoping issues; and (3) procedure implementation. All were considered to be SL 4 violations NRC PERSONNEL ISSUES / STATUS:

a)

Edwin Lea starts on a one year assignment at Watts Bar next week.

b)

Credit Hours authorized: None

ISSUES / ACTIVITIES EXPECTED NEXT WEEK:

Crystal River: -

Emergency Preparedness Exercise on 10/16/96

-

Regional inspection into the Corrective Action Program

-

Vehicle Barrier System Inspection St Lucie - Regional allegation inspection on Emergency Preparedness Program

- Regional Inspection into the Nuclear Instrumentation design control issue which resulted in three inoperable NI channels during startup l

'

l

.

.

!

..

,

i

,

,

'

.

WEEKLY. BRANCH CHIEF STATUS REPORT

'

.

SI' NATURE Kerry D. Landis DATE 10/24/96 BR5NCH3

~

G PLANT ISSUES / EVENTS:

a)

'St Luctel-Units 1 and 2 operated at 100% for the entire wee'.

k

'

' b).

Turkey' Point - Unit 3 operated at 100% for the entire week.

Unit 4 repaired a FW

!

-

heater leak by. plugging over 30 tubes and repaired the FW heater relief valves. Unit:

4 uprate is scheduled for next week.

a c)-

Crystal River.- FPC plans-to_~ remain. shutdown for the remainder of the year to restore l

i greater design margin in some systems and submit _the necessary license amendments..The.

pending _ license amendment 1s to re, solve several : US0s.on EDG loading. and 'EFW susceptibility to single failure.

.

.

' Emergency Preparedness Exercise was conducted on 10/16/96, no major deficiencies were Lidenti fied.

.

SIGNIFfCANT INSPECTION FINDINGS / INITIATIVES:

~

a)

Crystal--River - Failure to perforril an adequate 10 CFR 50.59 evaluation on diesel generator loading following a modification to remove the automatic. start of the turbine driven auxiliary feedwater pump.

-

b)

Crystal River EFW susceptibility to single failure: during LOOP'a failure of one fuse could cause an EFW flow control valve to fail.open allowing one EFW pump to go to runoute Since both EFW pumps draw suction through the same pipe, the resulting flowrate would cause cavitation and failure of both EFW. pumps.

Jc)-

-St Lucie/ Turkey Point - A vulnerability was identified in the safeguards process for FPL where the access authorization was not immediately removed for individuals whose Eemployment was terminated. One individual after employment termination reentered the site _ approximately five time for a total of 15 hours1.736111e-4 days <br />0.00417 hours <br />2.480159e-5 weeks <br />5.7075e-6 months <br />.

NRC PERSONNEL: ISSUES / STATUS:

a):

Credit Hours authorized: None

ISSUES / ACTIVITIES EXPECTED NEXT WEEK:

Crystal River:

. Safeguards inspection 10/30 SALP Board

.

-

'

-

'10/31. Tampering Public Exit \\ Engin'eering Performance Meeting

-

- 1Cahill a't CR;3 for SRIiturnover-

St Lucie

- Emergency Preparedness Program Inspection l

i

.

i

'

l

'

-

,

,

.