|
---|
Category:CORRESPONDENCE-LETTERS
MONTHYEARML17241A5001999-10-21021 October 1999 Forwards Rev 3 to Emergency Response Data Sys (ERDS) Data Point Library for St Lucie Unit 1.Rev Provides Replacement Pages & Follows Format Recommended by NUREG 1394, ERDS Implementation, Rev 1,App C ML17309A9981999-10-19019 October 1999 Forwards Revised Epips,Including Rev 3 to EPIP-10 & Rev 25 to HP-202.EPIP-10 Added Onsite Monitoring Points,Made Administrative Changes & Incorporated New Attachments & HP-202 Added Red Team Survey Points ML20217F6171999-10-0808 October 1999 Forwards Insp Repts 50-335/99-11 & 50-389/99-11 on 990827 & 990907-09.No Violations Identified.Matl Encl Contained Safeguards Info as Defined by 10CFR73.21 & Disclosed to Unauthorized Individuals Prohibited by Section 147 of AEA ML17241A4811999-10-0101 October 1999 Reports Number of Tubes Plugged During Unit 1 Refueling Outage SL1-16,per TS 4.4.5.5.a ML20212M1601999-09-28028 September 1999 Refers to 990908 Engineering Meeting Conducted at NRC Region II to Discuss Engineering Issues at Lucie & Turkey Point Facilities.List of Attendees & Copy of Presentation Handout Encl ML17241A4701999-09-25025 September 1999 Forwards Info Requested by NRC Staff During 990916 Telcon to Complete Staff Review of Request for risk-informed Extension of Action Completion/Aot Specified for Inoperable Train of LPSI Sys at Plant ML17241A4721999-09-24024 September 1999 Forwards Rev 1 to Plant Change/Mod (PCM) 99016 to St Lucie Unit 1,Cycle 16 COLR, IAW TS 6.9.1.11.d.Refueling Overhaul Activities Are Currently in Progress & Reactor Operations for Cycle 16 Are Scheduled to Commence in Oct 1999 ML17241A4681999-09-22022 September 1999 Requests Restriction Be Added to Senior Operator License SOP-21093 for TE Bolander.Nrc Forms 369,encl.Encl Withheld Per 10CFR2.790(a)(6) ML17241A4671999-09-20020 September 1999 Forwards Completed NRC Form 536, Operator Licensing Exam Data, for St Lucie Units 1 & 2,as Requested in Administrative Ltr 99-03, Preparation & Scheduling of Operator Licensing Exams. ML17241A4581999-09-13013 September 1999 Forwards Info Requested by NRC Staff During 990630 & 0816 Telcons,To Complete Review of Proposed License Amend for Fuel Reload Process Improvement Program ML17241A4531999-08-31031 August 1999 Informs That No Candidates from St Lucie Plant Will Be Participating in PWR Gfes Being Administered on 991006 ML17241A4521999-08-31031 August 1999 Withdraws Relief Request 16 & Suppl Relief Request 15 with Info Requested During 990526 Telephone Conference Re ISI Insp Plan,Third 10-yr Interval ML17241A4501999-08-26026 August 1999 Informs That FPL Has Reviewed Reactor Vessel Integrity Database,Called RVID2,re Closure of GL 92-01,rev 1,suppl 1. Requested Corrections & Marked Up Pages from Rvid 2 Database Summary Repts That Correspond to Comments,Attached ML17241A4371999-08-13013 August 1999 Forwards fitness-for-duty Program Performance Data for six- Month Period Ending 990630,per 10CFR26.71(d) ML17241A4461999-08-11011 August 1999 Requests That W Rept Entitled, Evaluation of Turbine Missile Ejection Probability Resulting from Extending Test Interval of Interceptor & Reheat Stop Valves at St Lucie Units 1 & 2, Be Withheld from Public Disclosure L-99-171, Forwards Rev 56 to Physical Security Plan.Summary of Changes & Marked Up Copy of Revised Pages Also Encl.Encls Withheld from Public Disclosure Per 10CFR2.790(a)(3)1999-07-29029 July 1999 Forwards Rev 56 to Physical Security Plan.Summary of Changes & Marked Up Copy of Revised Pages Also Encl.Encls Withheld from Public Disclosure Per 10CFR2.790(a)(3) ML17309A9911999-07-26026 July 1999 Forwards Revised EPIPs & Revised Procedures That Implement Emergency Plan as Listed.Procedures Provides Instruction for Operational Support Ctr (OSC) Chemistry Supervisor to Establish Remote Labs at Locations Specified ML17241A4471999-07-22022 July 1999 Requests That Rev 1 to WCAP-14732 & Rev 1,Add 1 to WCAP-14732 Be Withheld from Public Disclosure ML17241A4221999-07-22022 July 1999 Forwards List of Proposed Licensing Actions for St Lucie Units 1 & 2,planned During Fys 2000 & 2001,in Response to Administrative Ltr 99-02, Operating Reactor Licensing Action Estimates. ML17241A4151999-07-22022 July 1999 Forwards Revised Relief Request 25 for Second 10-yr ISI Interval for Unit 2 ML17241A4101999-07-16016 July 1999 Forwards FP&L Supplemental Response to NRC Request for Info Re Y2K Readiness at Nuclear Power Plants ML17309A9881999-07-0707 July 1999 Forwards Rev 5 to EPIP-03, Emergency Response Organization Notification/Staff Augmentation. Rev 5 to EPIP-03 Was Revised to Transfer EP Responsibilities from Training Manager to Protection Svcs Manager ML20209F1541999-07-0606 July 1999 Informs That NRC in Process of Conducting Operational Safeguards Response Evaluations at Nuclear Power Reactors. Plant Chosen for Such Review Scheduled for Wk of 990823-26 ML17241A4011999-06-30030 June 1999 Forwards Info Copy of Florida Wastewater Permit (FL0002208) (Formerly NPDES Permit) Mod,Which Was Issued by Florida Dept of Environ Protection on 990604 ML17241A3971999-06-30030 June 1999 Forwards Suppl Response to GL 96-05, Periodic Verification of Design-Basis Capability of Safety-Related Movs, as Requested in 990317 Ltr ML17355A3661999-06-30030 June 1999 Forwards Florida Power & Light Topical QA Rept, Dtd June 1999.Encl I Includes Summary of Changes Made to Topical QA Rept Since 1998 ML17241A3951999-06-29029 June 1999 Provides Response to NRC Request for Info Re Y2K Readiness at Nuclear Power Plants.Gl 98-01, Y2K Readiness of Computer Sys at Nuclear Power Plants, Requested Response on Status of Facility Y2K Readiness by 990701.Disclosure Encl ML17241A3731999-06-17017 June 1999 Supplements Relief Requests 4,11 & 13 for Third ten-year ISI Interval with Info Requested During 990526 Telcon.Expedited Review Is Requested by 990730 to Avoid Negatively Impacting Upcoming St Lucie Unit 1 Refueling Outage (SL1-16) ML17241A3641999-06-14014 June 1999 Submits Supplement to Relief Request 24 with Info Requested by Nrc.In Addition Relief Request 24 Is Identical to St Lucie Unit 1 Relief Request 4 for Third ISI Interval Being Supplemented by FPL Ltr L-99-139 ML20195F3871999-06-11011 June 1999 Final Response to FOIA Request for Documents.App a Records Being Withheld in Entirety (Ref FOIA Exemption 5) IA-99-247, Final Response to FOIA Request for Documents.App a Records Being Withheld in Entirety (Ref FOIA Exemption 5)1999-06-11011 June 1999 Final Response to FOIA Request for Documents.App a Records Being Withheld in Entirety (Ref FOIA Exemption 5) L-99-129, Forwards Rev 55 to Physical Security Plan,Summary of Changes & Marked Up Copy of Revised Pages.With Directions for Incorporating Rev Into Plan & Copies of Replacement Pages.Rev Withheld,Per 10CFR2.790(a)(3)1999-06-0909 June 1999 Forwards Rev 55 to Physical Security Plan,Summary of Changes & Marked Up Copy of Revised Pages.With Directions for Incorporating Rev Into Plan & Copies of Replacement Pages.Rev Withheld,Per 10CFR2.790(a)(3) ML17241A3561999-06-0707 June 1999 Forwards Rept Containing Brief Description & Summary of SEs for Changes,Tests & Experiments Which Were Approved for Unit 3 During Period of 970526-981209 ML17241A3601999-06-0707 June 1999 Forwards Correction to Annual Radiological Environ Operating Rept for CY98.Util Has Identified Transcription Error on Last Page of Attachment C of Rept,Results from Interlaboratory Comparison Program 1998 ML20195F3941999-05-27027 May 1999 FOIA Request That Memo from J Calvo to Fl Lebdon Re TIA - St Lucie,Unit 1 Environ Qualification of Woodward Governor Controls Be Placed in PDR ML17241A3461999-05-24024 May 1999 Forwards Revised Relief Request 22 to Clarify Several Areas of Relief.Nrc Action Is Requested to Be Complete by Aug 1999 to Support Planning for Spring 2000 Unit 2 Refueling Outage ML17241A3391999-05-20020 May 1999 Forwards Notification of Change to Small Break LOCA ECCS Evaluation Model Used for St Lucie Unit 1.Anomaly Was Discovered & Corrected That Resulted in Reducing Calculated PCT for Limiting SBLOCA by More than 50 F ML17241A3371999-05-20020 May 1999 Forwards Util Suppl to GL 95-07 Response Re pressure-locking & Thermal Binding of safety-related power-operated Gate Valves,In Response to NRC Second RAI Dtd 990225 ML20207C7531999-05-17017 May 1999 Discusses Issue Identified by FPL in Feb 1998 Involving Potential for Fire to Cause Breach of Rc Sys High/Low Pressure Interface Boundary & NRC Decision for Exercise of Enforcement Discretion ML17241A3301999-05-17017 May 1999 Forwards LER 99-004-00 Re as Found Cycle 10 Psv Setpoints Outside TS Limits,Which Occurred on 990415.Root Cause Determination Not Yet Complete.Suppl to Include Root Cause & Corrective Actions Will Be Submitted ML17309A9821999-05-10010 May 1999 Forwards Rev 36 to St Lucie Emergency Plan, Per 10CFR50.54(q).Executive Summary & Summary of Changes Incorporated by Rev,Encl IR 05000335/19980141999-04-29029 April 1999 Provides Confirmation of NRC Staff Conclusions Re Cited & non-cited Violations in Insp Rept 50-335/98-14 & 50-389/98-14.Utils Position Re Consideration of Multiple Spurious Actuations in Event of Fire,Reiterated ML17241A3221999-04-29029 April 1999 Provides Confirmation of NRC Staff Conclusions Re Cited & non-cited Violations in Insp Rept 50-335/98-14 & 50-389/98-14.Utils Position Re Consideration of Multiple Spurious Actuations in Event of Fire,Reiterated ML17229B1071999-04-28028 April 1999 Forwards 1998 Annual Environ Operating Rept for St Lucie Unit 2. Rept Includes Discussions of 5-inch Barrier Net Maint & Taprogge Condenser Tube Cleaning Sys Ball Loss,As Agreed at First Biennial Sea Turtle Meeting Held on 980120 ML17229B1051999-04-22022 April 1999 Requests That Listed Individuals Be Placed on Official Serve List for Nuclear Matl Safety & Safeguards Info Notices ML17229B1061999-04-21021 April 1999 Notifies NRC of Change in Medical Status of Licensed Operator Pf Farnsworth (Docket 55-21285,license SOP-21094). NRC Form 3996, Medical Exam Certification, Encl.Encl Withheld Per 10CFR2.790(a)(6) ML17309A9851999-04-15015 April 1999 Requests That NRC Review Denial of Appeal from Assessment of Fees Assessed in 981101 Invoice RS0062-99 & Assessment of Fees in Invoice RS0182-99 Which Was Also Denied in 990305 Ltr.Both Invoices Are for Fees Re Inspector GG Warnick ML20205M0431999-04-13013 April 1999 Eighth Partial Response to FOIA Request for Records.App Q & R Records Encl & Being Made Available in PDR ML17229B0951999-04-0808 April 1999 Requests Approval of Encl Revised Relief Request 6,in Response to 990322 Telcon with NRC & 10CFR55.55a(a)(3). Request States That Visual VT-3 Exams Will Be Conducted IAW IWA-2213 & Repairs Will Be IAW Util ASME Section IX Program ML17229B0821999-04-0707 April 1999 Requests Approval of Interim Relief Request 26 Re Repair Requirements for Class 2 ECCS Piping,Per 10CFR50.55a(a)(3) & 50.55a(g)(iii).Alternative Actions Apply Guidance of GLs 91-18 & 90-05 & ASME Code Case N-513.Evaluation,encl 1999-09-28
[Table view] Category:INCOMING CORRESPONDENCE
MONTHYEARML17241A5001999-10-21021 October 1999 Forwards Rev 3 to Emergency Response Data Sys (ERDS) Data Point Library for St Lucie Unit 1.Rev Provides Replacement Pages & Follows Format Recommended by NUREG 1394, ERDS Implementation, Rev 1,App C ML17309A9981999-10-19019 October 1999 Forwards Revised Epips,Including Rev 3 to EPIP-10 & Rev 25 to HP-202.EPIP-10 Added Onsite Monitoring Points,Made Administrative Changes & Incorporated New Attachments & HP-202 Added Red Team Survey Points ML17241A4811999-10-0101 October 1999 Reports Number of Tubes Plugged During Unit 1 Refueling Outage SL1-16,per TS 4.4.5.5.a ML17241A4701999-09-25025 September 1999 Forwards Info Requested by NRC Staff During 990916 Telcon to Complete Staff Review of Request for risk-informed Extension of Action Completion/Aot Specified for Inoperable Train of LPSI Sys at Plant ML17241A4721999-09-24024 September 1999 Forwards Rev 1 to Plant Change/Mod (PCM) 99016 to St Lucie Unit 1,Cycle 16 COLR, IAW TS 6.9.1.11.d.Refueling Overhaul Activities Are Currently in Progress & Reactor Operations for Cycle 16 Are Scheduled to Commence in Oct 1999 ML17241A4681999-09-22022 September 1999 Requests Restriction Be Added to Senior Operator License SOP-21093 for TE Bolander.Nrc Forms 369,encl.Encl Withheld Per 10CFR2.790(a)(6) ML17241A4671999-09-20020 September 1999 Forwards Completed NRC Form 536, Operator Licensing Exam Data, for St Lucie Units 1 & 2,as Requested in Administrative Ltr 99-03, Preparation & Scheduling of Operator Licensing Exams. ML17241A4581999-09-13013 September 1999 Forwards Info Requested by NRC Staff During 990630 & 0816 Telcons,To Complete Review of Proposed License Amend for Fuel Reload Process Improvement Program ML17241A4531999-08-31031 August 1999 Informs That No Candidates from St Lucie Plant Will Be Participating in PWR Gfes Being Administered on 991006 ML17241A4521999-08-31031 August 1999 Withdraws Relief Request 16 & Suppl Relief Request 15 with Info Requested During 990526 Telephone Conference Re ISI Insp Plan,Third 10-yr Interval ML17241A4501999-08-26026 August 1999 Informs That FPL Has Reviewed Reactor Vessel Integrity Database,Called RVID2,re Closure of GL 92-01,rev 1,suppl 1. Requested Corrections & Marked Up Pages from Rvid 2 Database Summary Repts That Correspond to Comments,Attached ML17241A4371999-08-13013 August 1999 Forwards fitness-for-duty Program Performance Data for six- Month Period Ending 990630,per 10CFR26.71(d) ML17241A4461999-08-11011 August 1999 Requests That W Rept Entitled, Evaluation of Turbine Missile Ejection Probability Resulting from Extending Test Interval of Interceptor & Reheat Stop Valves at St Lucie Units 1 & 2, Be Withheld from Public Disclosure L-99-171, Forwards Rev 56 to Physical Security Plan.Summary of Changes & Marked Up Copy of Revised Pages Also Encl.Encls Withheld from Public Disclosure Per 10CFR2.790(a)(3)1999-07-29029 July 1999 Forwards Rev 56 to Physical Security Plan.Summary of Changes & Marked Up Copy of Revised Pages Also Encl.Encls Withheld from Public Disclosure Per 10CFR2.790(a)(3) ML17309A9911999-07-26026 July 1999 Forwards Revised EPIPs & Revised Procedures That Implement Emergency Plan as Listed.Procedures Provides Instruction for Operational Support Ctr (OSC) Chemistry Supervisor to Establish Remote Labs at Locations Specified ML17241A4221999-07-22022 July 1999 Forwards List of Proposed Licensing Actions for St Lucie Units 1 & 2,planned During Fys 2000 & 2001,in Response to Administrative Ltr 99-02, Operating Reactor Licensing Action Estimates. ML17241A4471999-07-22022 July 1999 Requests That Rev 1 to WCAP-14732 & Rev 1,Add 1 to WCAP-14732 Be Withheld from Public Disclosure ML17241A4151999-07-22022 July 1999 Forwards Revised Relief Request 25 for Second 10-yr ISI Interval for Unit 2 ML17241A4101999-07-16016 July 1999 Forwards FP&L Supplemental Response to NRC Request for Info Re Y2K Readiness at Nuclear Power Plants ML17309A9881999-07-0707 July 1999 Forwards Rev 5 to EPIP-03, Emergency Response Organization Notification/Staff Augmentation. Rev 5 to EPIP-03 Was Revised to Transfer EP Responsibilities from Training Manager to Protection Svcs Manager ML17241A4011999-06-30030 June 1999 Forwards Info Copy of Florida Wastewater Permit (FL0002208) (Formerly NPDES Permit) Mod,Which Was Issued by Florida Dept of Environ Protection on 990604 ML17241A3971999-06-30030 June 1999 Forwards Suppl Response to GL 96-05, Periodic Verification of Design-Basis Capability of Safety-Related Movs, as Requested in 990317 Ltr ML17355A3661999-06-30030 June 1999 Forwards Florida Power & Light Topical QA Rept, Dtd June 1999.Encl I Includes Summary of Changes Made to Topical QA Rept Since 1998 ML17241A3951999-06-29029 June 1999 Provides Response to NRC Request for Info Re Y2K Readiness at Nuclear Power Plants.Gl 98-01, Y2K Readiness of Computer Sys at Nuclear Power Plants, Requested Response on Status of Facility Y2K Readiness by 990701.Disclosure Encl ML17241A3731999-06-17017 June 1999 Supplements Relief Requests 4,11 & 13 for Third ten-year ISI Interval with Info Requested During 990526 Telcon.Expedited Review Is Requested by 990730 to Avoid Negatively Impacting Upcoming St Lucie Unit 1 Refueling Outage (SL1-16) ML17241A3641999-06-14014 June 1999 Submits Supplement to Relief Request 24 with Info Requested by Nrc.In Addition Relief Request 24 Is Identical to St Lucie Unit 1 Relief Request 4 for Third ISI Interval Being Supplemented by FPL Ltr L-99-139 L-99-129, Forwards Rev 55 to Physical Security Plan,Summary of Changes & Marked Up Copy of Revised Pages.With Directions for Incorporating Rev Into Plan & Copies of Replacement Pages.Rev Withheld,Per 10CFR2.790(a)(3)1999-06-0909 June 1999 Forwards Rev 55 to Physical Security Plan,Summary of Changes & Marked Up Copy of Revised Pages.With Directions for Incorporating Rev Into Plan & Copies of Replacement Pages.Rev Withheld,Per 10CFR2.790(a)(3) ML17241A3601999-06-0707 June 1999 Forwards Correction to Annual Radiological Environ Operating Rept for CY98.Util Has Identified Transcription Error on Last Page of Attachment C of Rept,Results from Interlaboratory Comparison Program 1998 ML17241A3561999-06-0707 June 1999 Forwards Rept Containing Brief Description & Summary of SEs for Changes,Tests & Experiments Which Were Approved for Unit 3 During Period of 970526-981209 ML20195F3941999-05-27027 May 1999 FOIA Request That Memo from J Calvo to Fl Lebdon Re TIA - St Lucie,Unit 1 Environ Qualification of Woodward Governor Controls Be Placed in PDR ML17241A3461999-05-24024 May 1999 Forwards Revised Relief Request 22 to Clarify Several Areas of Relief.Nrc Action Is Requested to Be Complete by Aug 1999 to Support Planning for Spring 2000 Unit 2 Refueling Outage ML17241A3371999-05-20020 May 1999 Forwards Util Suppl to GL 95-07 Response Re pressure-locking & Thermal Binding of safety-related power-operated Gate Valves,In Response to NRC Second RAI Dtd 990225 ML17241A3391999-05-20020 May 1999 Forwards Notification of Change to Small Break LOCA ECCS Evaluation Model Used for St Lucie Unit 1.Anomaly Was Discovered & Corrected That Resulted in Reducing Calculated PCT for Limiting SBLOCA by More than 50 F ML17241A3301999-05-17017 May 1999 Forwards LER 99-004-00 Re as Found Cycle 10 Psv Setpoints Outside TS Limits,Which Occurred on 990415.Root Cause Determination Not Yet Complete.Suppl to Include Root Cause & Corrective Actions Will Be Submitted ML17309A9821999-05-10010 May 1999 Forwards Rev 36 to St Lucie Emergency Plan, Per 10CFR50.54(q).Executive Summary & Summary of Changes Incorporated by Rev,Encl ML17241A3221999-04-29029 April 1999 Provides Confirmation of NRC Staff Conclusions Re Cited & non-cited Violations in Insp Rept 50-335/98-14 & 50-389/98-14.Utils Position Re Consideration of Multiple Spurious Actuations in Event of Fire,Reiterated IR 05000335/19980141999-04-29029 April 1999 Provides Confirmation of NRC Staff Conclusions Re Cited & non-cited Violations in Insp Rept 50-335/98-14 & 50-389/98-14.Utils Position Re Consideration of Multiple Spurious Actuations in Event of Fire,Reiterated ML17229B1071999-04-28028 April 1999 Forwards 1998 Annual Environ Operating Rept for St Lucie Unit 2. Rept Includes Discussions of 5-inch Barrier Net Maint & Taprogge Condenser Tube Cleaning Sys Ball Loss,As Agreed at First Biennial Sea Turtle Meeting Held on 980120 ML17229B1051999-04-22022 April 1999 Requests That Listed Individuals Be Placed on Official Serve List for Nuclear Matl Safety & Safeguards Info Notices ML17229B1061999-04-21021 April 1999 Notifies NRC of Change in Medical Status of Licensed Operator Pf Farnsworth (Docket 55-21285,license SOP-21094). NRC Form 3996, Medical Exam Certification, Encl.Encl Withheld Per 10CFR2.790(a)(6) ML17309A9851999-04-15015 April 1999 Requests That NRC Review Denial of Appeal from Assessment of Fees Assessed in 981101 Invoice RS0062-99 & Assessment of Fees in Invoice RS0182-99 Which Was Also Denied in 990305 Ltr.Both Invoices Are for Fees Re Inspector GG Warnick ML17229B0951999-04-0808 April 1999 Requests Approval of Encl Revised Relief Request 6,in Response to 990322 Telcon with NRC & 10CFR55.55a(a)(3). Request States That Visual VT-3 Exams Will Be Conducted IAW IWA-2213 & Repairs Will Be IAW Util ASME Section IX Program ML17229B0821999-04-0707 April 1999 Requests Approval of Interim Relief Request 26 Re Repair Requirements for Class 2 ECCS Piping,Per 10CFR50.55a(a)(3) & 50.55a(g)(iii).Alternative Actions Apply Guidance of GLs 91-18 & 90-05 & ASME Code Case N-513.Evaluation,encl ML17229B0851999-04-0505 April 1999 Requests Approval of Encl Relief Request 25 Which Proposes to Use Alternative Requirements of ASME Code Case N-613 in Lieu of Requirements of ASME Section XI Figures IWB-2500-7(a) & IWB-2500-7(b).Action Requested by Aug 1999 ML17309A9791999-03-31031 March 1999 Forwards Revised EPIPs Including Rev 2 to EPIP-00,rev 2 to EPIP-09,rev 2 to EPIP-10 & Rev 10 to HP-207.Summary of Revs Listed ML17309A9761999-03-23023 March 1999 Forwards Revised Epips,Including Rev 4 to EPIP-03, Er Organization Notification/Staff Augmentation, Rev 3 to EPIP-05, Activation & Operation of OSC & Rev 14 to HP-200, HP Emergency Organization. Changes to Epips,Discussed ML17229B0691999-03-19019 March 1999 Transmits TS Pages Requested by NRC for Use in Issuance of Proposed License Amend Re SFP Storage Capacity,Per Soluble Boron Credit ML17229B0721999-03-16016 March 1999 Requests Approval of Enclosed Relief Requests 23 & 24 Re ISI Plan for Second ten-year Interval.Nrc Action Is Requested to Be Complete by Aug 1999 to Support Planning for Spring 2000 Unit 2 Refueling Outage ML17355A2631999-03-12012 March 1999 Forwards FPL Decommissioning Fund Status Repts for St Lucie, Units 1 & 2 & Turkey Point,Units 3 & 4.Rept for St Lucie, Unit 2 Provides Status of Decommissioning Funds for All Three Owners of That Unit ML17229B0481999-03-10010 March 1999 Informs That Util Delivered Matls Requested in Encl 1 of NRC Ltr by Hand on 990308,as Requested by NRC Ltr Dtd 990218 1999-09-25
[Table view] |
Text
_ _ _ _ _ __ _ _ _ _ . _ _ _ . __ _ .- _ _ . _ _ - - _ _ _ _
=. # .n
. . . . . . . ~* u.
- }
~
}'.'.es-., ,
~ '
j i i
i
!- tunpopowen a uomr cowav
[ .
j q~ Septeaser22,1981 i, .1.-81 415 i
- i
'0 Mr. James P.l0'Reilly. Director, Region !!
i! Office of Inspecttom and Enforcement i .
U. 3. Nuclear Regulhtory Commission '
101 Marietta Atlanta, Georgiastreet 30llDT. 4.Jutte 3100
- 'i 1
Dear Mr. O'Reilly:
s a
Re: St. Lucie Unit 1 I
. ! Docket Noa 50-335 - .
$20 Refueling Sheervisor -
!! Circular 80-t1-1 i'
NRC !E Circular No. 40-21 states that the NRC interpretation of the
} "directly supervisedt means that the SR0 in charge:of fuel handlin
!1 4
- supervising the coro alterations from the refuell.ng 7<" deck". * * 'T7g is The St. Lucie Plant s ,
- {
productive. taff feels that this interpretation is counter. *
- The extsting staffing which has been utilized for the past jj t
the intent ofinthe meets, as a minimum, accordance with the Plant Technical Specifications Circular for the following reason 1) i much better overall control and coordination. Maintainin es all refueling stattanesusing the refueljng status board and is in con Additionally instrumented to tie the center of overa,ll plant operationsthe Plactng the of control roo 3R0 on the refuelling deck removes his from the mainstream .
{ awareness of over)all plant operption. communications. p an
[- 2) 1 rapidly to the sp6nt fuel pool area where fuel m
- j. ..
occurring.
- 3)- St. Lucie utilizes
'j 3
licensed operators on the refueling machine, th's spent fuel machine and on the communication mheadset monttor wide rangei nuclear ~ instrumentation. to in th j;
may employbe intendedfuel non.11consed tolhandlers.
provida more supervision at those utilities whi i
5
< existing arrangeseht exceeds the intent uf .the Circular.If so, tt.is fe l2 9703120194 970306
' Attachment 2
- bOE 485, PDR JROM USyRc;sT. LUCIEi
- _-07/RW.9A.0 N
i.
t e. ' "x.~ ~. . .9.. .~. . s . . . :u .r.: er. . . . .
ac~ - ~ .. m L: s . ..
l, _ . e. O'Reilly, Director I .
' 4) deck is not:censistent with corporateees.and ueling reg For, the above edesons, and our opinion that adherence to the state 4
i Interpretation would detract from, ratner than enhance ,
policy and the requiromants. of the Technical .
with past Requiring the Specj refueling areas is more conducive to safeallfuel i
described in the NRC Circular, I' 1 i As a result of a telephone conversation on September !
Dance of your staff, it is our unoerstanding.the gn j
qk i regarding the stationing of the SRO in charge o f. .
room. W ng j e furtherlunderstand th a control lt Inspectors of this concurrence.at you will inform the site NRC Resident
{ Very truly yours, {
- - gp, g g _ 1 i 7 f
Robert E. Uhrig ii t Vice President Advanced Systems & Technology REU/PXG/ ras '
it -
- s' Attachment i
cc: Harold Reis. Esquire t
ej .
4 i
')
i l
I Attachment 2 i
I
- , 1 4
i.
j FROM USHRC ST. LUCIE , 07/28/94 0.6 : 3 5. . P.IR -
~~ ~
~~
/ . ,%, .l 1
UNITED STATES i* ! ~[ i,
- ;; . , . NUCLEAR REGULATORY COMMISSION .
49 8'.: i REGION il .
- t i toi a44sestv4 er.. n ev., susf r stoo "
.Af ATLANTA. CEORolA 20303 ng s ees yg,Y E LJ liCT SEP 3 0 : sat g Sol
\, ,.
n .. . :* "; ~. .e.a.. 5,,
I
- Florida Power and Light Company ATTH: Dr. R. E. Uhrig, Vice
- President, Advanced Systems I and Technology r.
i P.O. Box 529100 Miami, FL 33152 .
Gentlemen: "-
Subject:
~a, IE Circular 80/21 ,
, Thank you for your letter of September 22, 1981 which confirms your
! conversation with Mr. H. C. Dance of our staff.
>j to require freedom to move thequickly "Refuelfng SR0" to supervise from the control room with th to all refueling areas.
We appreciate your cooparation with us.
'Q.
.sf',
i ElJ.Vp1)bgji, Chief #
I Reictor Projects Branch 2, ,
Division of Resident and-j Reactor Project Inspection cc: C. H. Weth
' Hat Weems,y, Plant Manager Manager QA Construction j
i i
c Attachment 3 gljoiGC&fT i
4 rage ou of no i- ST LUC 1'd PLANT '
F PREOPERATIONAL TEST PROCEDURE No. 3200000, PtEVISION 6 i
- REFUELING OPERATION i
APPENDIX E '
j RECOMMENDED MOVE UST
) EXAMPLE DATA SHEET 4
'4 l Prem i i To i saw e Amewy ire 1l c. core erwoei Treuey, sPP I NPS- Wener Core Ortege, TroNey SPP Seemse j 1 70 711 R9 MA MOVE W j g da Est Sta 1 "^ MOVE.W i 3 30 L17 RIO .
OEA M OVE. W
$' 4 113 L3 03
' "^ MOVE.W 5 100 Lil L17 "^ MOVE w i, 6 a31 IW L2 " a" B57.21 West Z3T Enews ceasele Wessel
- l 7 831 EW 831 F43A , 700,91 West 234 answo Cemen a Vermeel j 3 gas 27tP X11 45FA4 yen ma , weeg 1mm - - -
- g_yggege.
,~
p gas sw L30 000.11 7A* ma , West i e t.w wwp Esmesamese a Westeel t .
10 GR5 E70' LS , " a* 808.16 i West XS4 Ennse Cassem a Vestem1a.
11 G35 NFU" N11 manA 79C.88 West 4
X3 Ennse Gamese t Vesteela .
12 GRB FFIP' J11 7"^" 780.07 West ' T37 Enswo Queen b Womes
', 13 G18 27tP L13 " a' 751.01 West T34 Enswo Gemen a Wasem
$. 14 GB0 EF W4 "" " " "- West i TER Ensw o Gem e m to Westeel 15 m 20 E7tr R30 1 Gia en y43,y4 Lg3 m am yyg3g gag j 18 16 s<v K7 57A4 815.5 N11 800A 79BAO 14A
- j. 17 .5FF EFIP W' M1.18 849A4 West IWF annue Gessessle Womeni
- j. Is #es et SEP 515 F"" "" 7" " J11 7== a" Fam_=7 1me i, 15 PW1 118 59' GE , 7" " 557.18 LS " " " ' 808.15 14d
{} 50 5 71 BIP . G4 7" "' I "'"."" West jj 31 575 WIP IIB 755.17 " " " West
' f34 ,
RE, Enswo Gemen b Weseget Egesse Onem t Vesueel l; 33 8 72 SIP D18 7"" " 7" " West i
NB7 - Enswo Qemen a Wesseel 33 get str C18 751.04 7"* "" West N34 Enews Cassem a Westeel i iI 34 573 IFIP V1D S41.15 7'a " West MBE Ennes Cassem toVerages i as aFe zw w1s == ,79= " West ' s3a samme cemen a Vanes
! Et, PE5 100 FFIP LF " a* 815A La " ^* SS7A1, 144
! 37 Met 34 NFtr G11 733.71 7an_ma .
311 743.4 i 799A1 1/M PMIDR TO CZ.'""LE
! as 557 E7EP GS 788A7 !" ^1 West N30 , Enewt Gemem a Woment
! RD -MD7 54 27tP R11 01Mp1 7mm na xgg , ggy4g yeana, I, ~
80 995 21 IFIP L15; ""A "" i 753A1 L50 gag,., ig yegannyptg 000.11 Ta' " 144 l1 et .mu - .= enle t" -i Wem
.= -mi mRr = nu, esr.m m7 ese.e Gen .W ne.
" a- .1 A .
I, at M10 err X15 55FA4, 753.91 L7 iAd R11 518,81 7mm _" 144 l M GES sir L11 800 000 West Ytr Enews Cemen le Vereaal i
i a5 Hla sw aan rua,7s 74a.71 L1s , "- FeaA1, W l
- F49esefDr Ressouses by_
j M- Appeesegmy_
I 8ta,agenneer .
i i
- /RS i
L .
Attachment 4 I
b e
JD . $
!~
FRO!1 USNRC ST. LUCIE 07/29/94 08: 46 P. 3 2 h iMI
l rage vi or o2 l p
P ST. LUCIE PLANT PREOPERATIONAL TEST PROCEDURE NO. 3200090, REVISION 6
)1 REFUELING OPERATION p <
12.0 DETAILED PROCEDURE: {%JN3[ '
i 12.1 The Operations Supervisor has reviewed the status of all CORE l
- j. ALTERATIONS, related systems, as well as the overall plant status, and ,
N authorizes the commencement of fuel movement. !
l Verified by Date / / '
'{ Operations Supervisor <
ii '
12.2 All required personnel are on station.
I Verified by Date / / '
i h - 12.3 All fuel and insert moves will be directed from the Refueling Control Center in the following manner.
'! 1. The Recommended Move List will be used as a move sequencing guide to refueling.
- 2. Deviations in the Recommended Move List sequence are permitted and i altamate locations may be utilized as temporary locations provided the l j following are observed:
t A. Sources, or fuel assemblies meeting the minimum bumup requirements of 9.8.1 RX-A10, RX Y10 (PSL 1) or RX-A10, RX-Y12
- (PSL 2) If required, will be located in before any other fuel moves are permitted, j B. Movement of an assembly is in accordance with the Fuel Assembly
- Storage Table (F.A.S.T.).
- C. Verify that the mast orientation is correct to support the new move.
D. Verify that as a result of removing an assembly, no other assemblies become free standing, i
El Verify that inserting an assembly into a new location in the core and ungrappling it would not cause it to be a free standing assembly.
F1 Verify that moving an assembly into a spent fuel Rack does not violate spent fuel pool region requirements or funnel requirements.
Attachment 5
)
l
~
TO*d 68LSTCEter1 01 WOtid Wd22:60' F66I-9I-90
!Q 1 j
' Page 20 of 52
)i ^
. ST. LUCIE PLANT ,
4 PREOPERATIONAL TEST PROCEDURE NO. 32000go REVISION 6 )
REFUELING OPERATION .
]
) 12.0 DETAILED PROCEDURE: (continued) {
!- 12.3 (continued) 5 l
1
- 2. (continued) .
t i !
4 G. Any deviation is approved by the Reactor Engineer on shift and the !
- i Refueling Coordinator (SRO).
jj H. If the deviation does affect the FRG approved Final Core Loading l Pattom, reactivity conservatism shall be ensured and FRG
- J re approval obtained prior to core verification.
- 3. The Refueling Control'Conter will inform the station conducting the move
. . which assembly is to be moved, it's present location as well as where it 1 l!
j is to be moved and changes in Refueling Machine mast orientadon if required.
l
- 1 3 1' 4. The station performing the move will acknowledge the directions issued l by the Refueling Control Center prior to any movement. For the j
' operator's convenience a Fuel Movement Log sim8ar to that provided in this procedure will be provided for recording the instruedons transmitted by the Refueling Control Center.
- y 12.4 Refueling Control Center. Operating Personnel Responsibilities J l1 \
l 1. Coordinate the movement of all fuel and core -.w.ents. Refer to
- Appendices C and D for insert and CEA transfer guidance.
3 , 2. Receive notification of core component movement and acknowledge j such notification by core component serial number (s), originating location, present location, core coordinates, and onentation of the i Refueling Machine mast.
- 3. Verify Bridge and Trolley coordinates (hoist position upon insertion of a fuel assembly) stated by Refueling Machine Operator are valid for the core coordinates in the refueling sequence ,for the appropriate step, record on the Fuel Movement Log.
f; 4. Track completion of each transfer by filling out the Fuel Movement Log.
The Fuel Movement Log will then be used by Reactor Engineering to
! com, Mete Appendix B, the final fuel transfer. sequence at the conclusion of the fuel move, then update the Fuel Status Magnet Board.
4 g
~
Attachment 5 l 'l
, .. \
. . . , . . . . . - . . . _y
. . e ims q (e w- y .cen *cc %onora _
l , _ _ ,