Semantic search

Jump to navigation Jump to search
 Issue dateTitleTopic
ML20217K45930 September 1999Monthly Operating Repts for Sept 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With
ML20217K80430 September 1999Rev 1 to Vegp,Unit 2 Cycle 7 ColrShutdown Margin
ML20217K77430 September 1999Rev 1 to Vegp,Unit 1 Cycle 9 ColrShutdown Margin
ML20216E50631 August 1999Monthly Operating Repts for Aug 1999 for Vegp,Units 1 & 2. with
ML20210P98431 July 1999Monthly Operating Repts for July 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With
ML20209H12130 June 1999Monthly Operating Repts for June 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With
ML20196F97131 May 1999Owner Rept for ISI for Vogtle Electric Generating Plant, Unit 1 Eighth Maint/Refueling OutageBoric Acid
Hydrostatic
Nondestructive Examination
VT-2
Liquid penetrant
ML20195G17331 May 1999Monthly Operating Repts for May 1999 for VEGP Units 1 & 2. with
ML20206N21430 April 1999Monthly Operating Repts for Apr 1999 for Vogtle Electric Generating Plant,Units 1 & 2.With
ML20206A65621 April 1999Safety Evaluation Authorizing Licensee Re Rev 9 to First 10-year ISI Interval Program Plan & Associated Requests for Relief (RR) 65 from ASME Boiler & Pressure Vessel CodeIncorporated by reference
ML18016A90112 April 1999Part 21 Rept Re Defect in Component of DSRV-16-4,Enterprise DG Sys.Caused by Potential Problem with Connecting Rod Assemblies Built Since 1986,that Have Been Converted to Use Prestressed Fasteners.Affected Rods Should Be Inspected
ML20206C22931 March 1999Revised Monthly Operating Repts for Mar 1999 for Vogtle Electric Generating Plant,Units 1 & 2
ML20205Q80831 March 1999Monthly Operating Repts for Mar 1999 for Vegp,Units 1 & 2. with
ML20205A95831 March 1999Rev 0 to VEGP Unit 1 Cycle 9 ColrShutdown Margin
ML20207K60528 February 1999Monthly Operating Repts for Feb 1999 for Vogtle Electric Generating Plant,Units 1 & 2.WithCoast down
ML20209H39515 February 1999Rev 2 to ISI Program Second 10-Year Interval Vogtle Electric Generating Plant Units 1 & 2Boric Acid
Hydrostatic
VT-2
Scaffolding
ML20209H40915 February 1999Rev 1 to ISI Program Second 10-Year Interval Vogtle Electric Generating Plant Units 1 & 2
ML20202H98529 January 1999Safety Evaluation Accepting Rev 8 to First 10-year Interval Inservice Insp Program & Associated Requests for Relief for Vogtle Electric Generating Plant,Unit 1Time of Discovery
Nondestructive Examination
Incorporated by reference
Scaffolding
Backfit
ML20199F80413 January 1999Corrected Pages to VEGP-2 ISI Summary Rept for Spring 1998 Maint/Refueling OutageHydrostatic
VT-2
Liquid penetrant
ML20199E75631 December 1998Monthly Operating Repts for Dec 1998 for Vogtle Electric Generating Plant,Units 1 & 2.With
ML20198S17831 December 1998SER Re Second 10-year Interval Inservice Insp Program Plan & Associated Requests for Relief for Southern Nuclear Operating Co,Inc Units 1 & 2Boric Acid
Nondestructive Examination
VT-2
Dissimilar Metal Weld
ML20196E5221 December 1998Rev 8 to ISI-P-014, ISI Program for VEGP-2Time of Discovery
Non-Destructive Examination
Hydrostatic
Nondestructive Examination
VT-2
Scaffolding
Backfit
ML20198B85730 November 1998Monthly Operating Repts for Nov 1998 for Vogtle Electric Generating Plant,Units 1 & 2.With
ML20195H21331 October 1998Monthly Operating Repts for Oct 1998 for Vogtle Electric Generating Station,Units 1 & 2.With
ML20154L56830 September 1998Monthly Operating Repts for Sept 1998 for Vegp,Units 1 & 2
ML20151W36831 August 1998Monthly Operating Repts for Aug 1998 for Vogtle Electric Generating Plant Units 1 & 2.With
ML20154L57231 August 1998Corrected Page from MOR for Aug 1998 for Vegp,Unit 2
ML20237D20531 July 1998Monthly Operating Repts for July 1998 for Vogtle Electric Generating Plant Units 1 & 2
ML20236V31229 July 1998Final Part 21 Rept Re Enterprise DSR-4 & DSRV-4 Edgs.Short Term Instability Was Found During post-installation Testing & Setup as Part of Design mod/post-work Testing Process. Different Methods Were Developed to Correct Problem
ML20236P69930 June 1998Monthly Operating Repts for June 1998 for Vogtle Electric Generating Plant,Units 1 & 2
ML20236Q30530 June 1998Owner'S Rept for ISI for Sixth Maint/Refueling Outage of Vogtle Electric Generating Plant,Unit 2
ML20249A39131 May 1998Monthly Operating Repts for May 1998 for Vogtle Electric Generating Plant
ML20248A16722 May 1998Interim Part 21 Re Enterprise DSR-4 & DSRV-4 Emergency diesel.Post-installation Testing Revealed,High Em/Rfi Levels Affected New Controllers,Whereas Original Controllers Were unaffected.Follow-up Will Be Provided No Later than 980731
ML20249A39330 April 1998Revised MOR for Apr 1998 for Vogtle Electric Generating Plant Unit 1
ML20247F38430 April 1998Monthly Operating Repts for Apr 1998 for Vogtle Electric Generating Plant,Units 1 & 2
ML20154Q97220 April 199810CFR50.59(B) Rept of Facility Changes,Tests & Experiments for Vogtle Electric Generating Plant,Units 1 & 2Loop seal
Packing leak
High Radiation Area
Grab sample
Fire Barrier
Stroke time
Hydrostatic
Temporary Modification
VT-2
Emergency Lighting
Incorporated by reference
Fire Protection Program
ML20217H7181 April 1998Corrected Page 5 to 980324 SER Re Relief Requests Associated W/Second 10-year Interval Insp program.RR-21 in Error in That Component,Suction Damper Inadvertently Omitted. Corrected Page 7 of Technical Ltr Rept Also Encl
ML20216D61431 March 1998Monthly Operating Repts for Mar 1998 for Vogtle Electric Generating Plant,Units 1 & 2
ML20217Q13031 March 1998Rev 0 to Vepc Unit 2 Cycle 7,COLRShutdown Margin
ML20217B88324 March 1998SER Accepting Relief Request RR-5,RR-19,RR-20,RR-21,RR-23 & RR-24 for Second 10-yr Interval ISI Program PlanBoric Acid
Hydrostatic
Nondestructive Examination
VT-2
Incorporated by reference
Pressure boundary leak
ML20216E24228 February 1998Monthly Operating Repts for Feb 1998 for Vogtle Electric Generating Plant,Units 1 & 2
ML20203H95523 February 1998SER Denying Quality Assurance Program Description Change for Vogtle Electric Generating Plant,Units 1 & 2
ML20203E48311 February 1998Rev 1 to Vogtle Electric Generating Plant,Units 1 & 2 Second Ten-Yr Interval Pump Inservice Test ProgramBoric Acid
ML20198T12131 January 1998Owners Rept for Inservice Inspection for Seventh Maintenance/Refueling OutageHydrostatic
Nondestructive Examination
VT-2
Liquid penetrant
ML20202G54431 January 1998Monthly Operating Repts for Jan 1998 for Vogtle Electric Generating Plant,Units 1 & 2
ML20199E54331 January 1998Rev 3 to WCAP-14720, Vogtle Units 1 & 2 Spent Fuel Rack Criticality Analysis W/Credit for Soluble BoronShutdown Margin
ML20198L64731 December 1997Monthly Operating Repts for Dec 1997 for Vogtle Electric Generating Plant,Units 1 & 2
ML20203C2819 December 1997Safety Evaluation Authorizing Request for Relief of Second 10 Yr Interval Inservice Insp Program
ML20202B7881 December 1997Rev 8 to ISI-P-006, ISI Program for Gpc Vogtle Electric Generating Plant Unit 1Time of Discovery
Hydrostatic
Nondestructive Examination
VT-2
Liquid penetrant
Backfit
ML20203H06030 November 1997Monthly Operating Repts for Nov 1997 for Vegp,Units 1 & 2