L C:mm:nwn:lth Edis:n 9 Zion Gin: rating Station 101 Shiloh Blvd.

Zion, Illinois 60099 Telephone 312/746-2084 Apri1 17, 1989 Director of Nuclear Reactor Regulation N

U.S. Nuclear Regulatory Commission -

Hall Station P1-137 Hashington, D.C. 20555

Subject:

Zion Nuclear Power Station, Units 1 and 2 License Nos. DPR-39 and DPR-48 i NRC Docket Nos. 50-295 and 50-304 Proposed Amendment to Technical Specification Sections 3.1 and 4.1. "Rgartor Protection System"  ;

i Gentlemen:

Attached is a proposed Technical Specification amendment for Zion Nuclear Power Station, License Nos. DPR-39 and DPR-48. The proposed amendment addresses Sections 3.1 and 4.1 " Reactor Protection System".

The purpose of this revision is to demonstrate compliance with NRC Generic Letter 85-09, entitled " Technical Specifications for Generic Letter 83-28, Item 4.3". The proposed Technical Specification change involves additions and clarifications to Tables 3.1-1 and 4.1-1 to address operability and surveillance requirements for Reactor Protection Channels. Specifically, this

. proposed amendment will change and/or clarify the operability and surveillance requirements for the following functions: 1) Manual Reactor Trip; 2)

Automatic Reactor Trip Logic; and 3) Reactor Trip and Bypass Breakers.

A summary of the changes is provided below.

1) Iahle13-L_page_30 Line_3 The line is changed to correct a spelling error. l
2) Jable 3.1-1. pAgas_3L3nd_32 dine _2. Land _ explanation of ED _fontaole The description of the Reactor Protection Channel has been changed ,

from " Automatic Reactor Trip Logic" to " Automatic Reactor Trip Logic, Including Reactor Trip Breakers". The change reflects the request of NRR technical reviewers regarding reactor trip logic, and is closely

, patterned after similar requirements in effect at Ginna. The (#)

! footnote has been added to clarify the appropriate action if one of l the diverse trip features is inoperable. This footnote is worded in accordance with Generic Letter 85-09.

(

3) lable_4J-1mpage_35mLtne 1 A note has been added to the " Remarks" column of Line 1 to address OPERABILITY of the undervoltage and shunt trip circuits, of the reactor trip breakers in addition to the OPERABILITY requirement of l the reactor bypass breaker circuit. These remarks closely parallel the guidance contained in Generic Letter 85-09.

8905010066 890417 PDR ADOCK 05000295 PNU (j

P 15 80 f I

l

d =

,4 l .

4 )' . 'Jable 4.1-1. Dage 36. Lines 21'. 22 and 23 a) Line.21 has been revised to add Remark No. 11 which requires testing of automatic reactor trip-logic of each train on alternate. months. The requirements of the Remark'are patterned 1

after Generic Letter 85-09 and; include the recommendations of NRC Staff personnel.who ' suggested that a similarity to Ginna requirements would be appropriate.

b)- Line 22 is an addition to the Table which specifies the Channel Functional Test requirements for the Reactor Trip Breakers. The comments contained in.the Remarks column closely conform _to Generic Letter 85-09.

c) Line 23 is an addition to the Table which specifies the Channel Functional Test requirements for the Reactor Trip Bypass l Breakers. The comments contained in the Remarks column closely j conform to Generic Letter 85-09. '

Attachment 1 cantains.the revised pages of the Technical Specifications.

Attachment 2 contains- the evaluation of significant hazards review.

As provided by 10 CFR50.91, the State of Illinois is being notified of- {

this amendment request by transmittal of this letter and attachments. '

Please direct any. questions that you may have to this office.  ;

i l'

Ver truly yours,

/ i G. E. Trzyn  ;

Nuclear Licensing {

Administrator  ;

Zion Station )

i cc: Chandu Patel - NRR NRC Resident Inspector - Zion M. C. Parker - IDNS l

1 I

l l

15180' I u____._____-.__. _. i

1 l

l 1

ATTACHMENT 1  !

1

. ZION NUCLEAR POWER STATION EROPOSED AMENDliENT.TO )

IECHNICAL SPECIFICATION l; SECTIONS 3.1 AND 4.1 I

l i

1 1

l 1

I 15180 t

i E __. _ _ . _ _ _ _ _ . _ _ _ _

4 ZION NUCLEAR POWER STATION PROPOSED AMENDMENT Pages Modified 30 31 32 35 36 Pages Added None Pages Deleted None l

l l