ML20212C878

From kanterella
Revision as of 14:25, 21 January 2021 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards Info Re Plant Snubbers,Including Date of Failures & Current safety-related Snubber Population
ML20212C878
Person / Time
Site: Farley  Southern Nuclear icon.png
Issue date: 02/27/1987
From: Mcdonald R
ALABAMA POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
TAC-62811, TAC-62812, NUDOCS 8703040018
Download: ML20212C878 (2)


Text

j---

Alabama Power Company 600 North 18th Street Post Office Box 2641 Birmingham, Alabama 352910400 Telephone 205 250-1835 AlabamaPower

' Senio V r sident 10CFR50.90 February 27, 1987 Docket Nos. 50-348 50-364 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555 Gentlemen:

Joseph M. Farley Nuclear Plant - Units 1 and 2 Snubber Surveillance Requirements Technical Specification Change By letters of September 2,1986 and February 9 and 25,1987, Alabama Power Company requested changes to Farley Huclear Plant Technical Specification 4.7.9.a and the accompanying Bases. At the request of the Farley Project Manager, the attached information pertaining to the Unit 1 and Unit 2 snubbers is provided.

If you have any questions, please advise.

Respectf My' submitted,

)

h' R. P. Mcdonald RPM / JAR: dst-T.S.6 Attachment cc: Mr. L. B. Long Dr. J. N. Grace Mr. E. A. Reeves Mr. W. H. Bradford [

5 0 o*i88 I l 4,e--- <--m- -ywp,--

o ATTACHMENT-FARLEY NUCLEAR PLANT SNUBBER HISTORY UNIT 1 FAILURES UNIT 2 FAILURES VISUAL VISUAL VISUAL VISUAL.

DATE INACCESSIBLE' ACCESSIBLE DATE INACCESSIBLE ACCESSIBLE 02/82- 1 1 05/79 1 0 10/82 1 0 ,

11/80 1 2 09/83 1 1 02/81 0 0 12/84 1 1-07/81 -N/A 0 04/86 1 1

-09/81 2 N/A 02/82 0 0 02/83 1 0 03/83 0 0 02/84 1 1 03/85 0 0 10/86 4 0 CURRENT UNIT 1 SAFETY RELATED SNUBBER POPULATION INACCESSIBLE ACCESSIBLE TOTAL

, Hydraulic 343 188 531 Mechanical 243 63 306 Total 586 251 837 l

CURRENT UNIT 2 SAFETY RELATED SNUBBER POPULATION INACCESSIBLE ACCESSIBLE TOTAL Hydraulic 175 189 364 Mechanical 256 48 304 Total 431 237 668