ML20204K090

From kanterella
Revision as of 14:43, 13 December 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Significant Deficiency Rept SDAR-173 Re Auxiliary Feedwater Pressure Control.Hydraulic & Instrumentation Calculations Which Will Result in Revised Setpoint & Scalling Documents Will Be Completed by 850531
ML20204K090
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 04/15/1985
From: Clements B
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To: Hunter D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
SDAR-173, TXX-4456, NUDOCS 8504250312
Download: ML20204K090 (2)


Text