Forwards Rept on Investigation of Reactor Coolant Pipe Weld Thickness at Diablo Canyon
ML20077H971
Person / Time
Site: Diablo Canyon Pacific Gas & Electric icon.png
Issue date: 07/05/1983
From: Schuyler J
PACIFIC GAS & ELECTRIC CO.
To: Martin J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
Shared Package
ML16340D651 List:
References
NUDOCS 8308120131
Download: ML20077H971 (1)


Text

.

4 4 C

3 PACIFIC OAS AND E LE C T RI C C O M PANY pggg . 77 BEALE STREET. SAN FR ANCISC O, C ALIFORNI A 94106 TELEPHON E (415) 781 4211 July 5, 1983 Mr. John B. Martin, Regional Administrator U. S. Nuclear Regulatory Commission, Region V 1450 Maria Lane, Suite 210 Walnuf Creek, CA 94596-5368 Re: Docket No. 50-275, OL-DPR-76 Diablo Canyon Unit 1

Dear Mr. Martin:

t .

Enclosed is Pacific Gas and Electric Company's Report on Investigation of Reactor Coolant Pipe Weld Thickness at Diablo Canyon, dated July 1,1983.

Sincerely, J. O. Schuyler Enclosure cc w/ enc: Document Control Desk (2)

U. S. Nuclear Regulatory Comission Washington, D.C. 20555 Mr. George W. Knighton, Chief Licensing Branch No. 3 Division of Licensing Office of Nuclear Reactor Regu'iation U. S. Nuclear Regulatory Comission Washington, D.C. 20555 Service List fhhjl830 sos PDR