DCL-90-038, Forwards Proprietary WCAP-12495 & Nonproprietary WCAP-12496, Review of Flow Peaking & Tube Fatigue in Diablo Canyon Units 1 & 2 Steam Generators Per El Murphy Aug 1989 Request

From kanterella
(Redirected from ML16341F558)
Jump to navigation Jump to search
Forwards Proprietary WCAP-12495 & Nonproprietary WCAP-12496, Review of Flow Peaking & Tube Fatigue in Diablo Canyon Units 1 & 2 Steam Generators Per El Murphy Aug 1989 Request
ML16341F558
Person / Time
Site: Diablo Canyon  
Issue date: 02/06/1990
From: Shiffer J
PACIFIC GAS & ELECTRIC CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML16341F559 List:
References
DCL-90-038, DCL-90-38, IEB-88-002, IEB-88-2, NUDOCS 9002230523
Download: ML16341F558 (6)


Text

ACCELERATED DISTBXBUTION DEMONSTRATION SYSTEM t

i REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9002230523 DOC.DATE: 90/02/06 NOTARIZED: YES DOCKET FACIL:50-275 Diablo Canyon Nuclear Power Plant, Unit 1, Pacific Ga 05000275 50-323 Diablo Canyon Nuclear Power Plant, Unit 2, Pacific Ga 05000323 AUTH.NAME AUTHOR AFFILIATION

~

MaP jdyg m SHIFFER,J.D.

Pacific Gas

& Electric Co.

RECIP.NAME RECIPIENT AFFILIATION blfgp ~jP Document Control Branch (Document Control Desk)

SUBJECT:

Forwards proprietary WCAP-12495 6 nonproprietary WCAP-12496, "Review of Flow Peaking 6 Tube Fatigue in Diablo Canyon...."

DISTRIBUTION CODE:

APOID COPIES RECEIVED:LTR D ENCLj SIZE:~

5 C

TITLE: Proprietary Review Distribution Operating Reactor NOTES:

RECIPIENT ID CODE/NAME PD5 LA ROOD, H COPIES LTTR ENCL 1

1 3

3 RECIPIENT ID CODE/NAME PD5 PD COPIES LTTR ENCL 1

1 INTERNAL: ACRS AEOD/DSP/TPAB

..REG FILE 0~

EXTERNAL:

PDR 6

6 1

1 1

1 AEOD/DOA OGC/HDS2 1

)IVP NRC PDR 1

1 1

0 1

Nt'cm gQ~5 2.

2 NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASIZt CONTACTTHE,DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAMEFROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED/

TOTAL NUMBER OF COPIES REQUIRED'TTR

+V ENCL P4 g.o l"t

l

'f

Pacific Gas and Eiectric Company 77 Beale Street San Francisco, CA 94106 415I972-7000 415/973-4684 0,

James

0. Shiffer Senior Vice President and General Hanager Nuclear Power Generation February 6,

1990 PGRE Letter No. DCL-90-038 U.S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, D.C.

20555 Re:

Docket No. 50-275, OL-DPR-80 Docket No. 50-323, OL-DPR-82 Diablo Canyon Units 1

and 2

Review of Flow Peaking and Tube Fatigue in Steam Generators Gentlemen:

HCAP-12064, "Diablo Canyon 1

and 2 Evaluation for Tube Vibration Induced Fatigue,"

was submitted to the NRC on November 30, 1988 (PG8E Letter DCL-88-290), in response to NRC Bulletin 88-02.

As requested by Emmett L. Murphy of the NRC Staff in August 1989, this letter provides additional information to supplement the Staff's review of the HCAP.

IDNO OOQ.

(VO OO OUj (jh.O

/JR (vu 80 OA (oct N

,OQ:

OQ WQ.Q.

During the NRC Staff's review of the Diablo Canyon tube fatigue evaluation, questions arose concerning the effect of penetration of the antivibration bars (AVBs) into row 7 on the flow peaking for tube R9C60 in steam generator (SG) l-l and tube R9C35 in SG 1-3.

In response to these questions, a complete review of the AVB locations in Diablo Canyon Units 1

and 2 was conducted.

This review resulted in corrections to the AVB maps and a reevaluation of flow peaking and tube fatigue susceptibility at a few tube locations.

The reevaluation disclosed that tube R9C60 in SG 1-1 required corrective action.

As discussed with the NRC Staff, the deci sion was made to install a cable damper stabilizer and solid plug in this tube.

This installation was made during the Unit 1 third refueling outage (1R3) in the fall of 1989.

All other tubes reevaluated in the study were found to meet acceptance criteria.

Nonetheless, a sentinel plug was installed in tube R9C35 in SG 1-3 as a conservative measure during 1R3.

In support of this supplemental information, enclosed are:

1.

HCAP-12495, "Review of Flow Peaking and Tube Fatigue in Diablo Canyon Units 1

and 2 Steam Generators" (Proprietary) 2.

HCAP-12496, "Review of Flow Peaking and Tube Fatigue in Diablo Canyon Units 1

and 2 Steam Generators" (Non-Proprietary)

Also enclosed is a Westinghouse authorization letter (CAW-90-005),

Proprietary Information Notice, and accompanying Affidavit (CAH-88-106).

// /'0 4r

~ur~y p W

( pu gw Lf<+

(

/~iver,foie i I tpcc Fw

1 l

t Document Control Desk PGEE Letter No. DCL-90-038 0

February 6, 1990 m

As HCAP-12495 contains information proprietary to Westinghouse Electric Corporation, it is supported by an affidavit signed by Westinghouse, the owner of the information.

The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph (b)(4) of Section 2.790 of the Commission's regulations.

Accordingly, it is respectfully requested that the information which is proprietary to Westinghouse be withheld from public disclosure in accordance with 10 CFR 2.790 of the Commission's regulations.

Correspondence with respect to the proprietary aspects of the Application for Withholding or the supporting Westinghouse Affidavit should reference CAN-90-005 and should be addressed to R. A. Hiesemann, Manager of Regulatory h Legislative Affairs, Westinghouse Electric Corporation, P.O.

Box 355, Pittsburgh, Pennsylvania 15230-0355.

Kindly acknowledge receipt of this material on the enclosed copy of this letter and return it in the enclosed addressed envelope.

incerely, 3.

D. Shiffer cc:

A. P.

Hodgdon J.

B. Martin M.

M. Mendonca P.

P. Narbut H.

Rood CPUC Diablo Distribution Enclosure 3044S/0077K/JHA/1968 (w/HCAP-12495)

(w/HCAP-12495)

(w/HCAP-12495)

(w/HCAP-12495)

(w/HCAP-12495)

(w/HCAP-12496)

(w/o Enc.)