2003 Inservice Inspection (ISI) Summary Report
ML032250165
Person / Time
Site: Kewaunee Dominion icon.png
Issue date: 08/06/2003
From: Coutu T
Nuclear Management Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NRC-03-082
Download: ML032250165 (168)


Text

NPi_

Committed to Nuclear Excellence Kewaunee Nuclear Power Plant Operated by Nuclear Management Company, LLC NRC-03-082 10CFR50.55a August 6, 2003 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 KEWAUNEE NUCLEAR POWER PLANT DOCKET 50-305 LICENSE No. DPR-43 2003 INSERVICE INSPECTION (ISI)

SUMMARY

REPORT As required by ASME Boiler and Pressure Vessel Code, Section Xl; Code of Federal Regulation 10CFR50.55a; and Wisconsin Administrative Code Department of Commerce, Subchapter V:

Chapter Comm. 41.55(3), various ISI examinations were performed as part of the 2003 Refueling Outage. The outage took place from April 5, 2003 through May 11, 2003; i.e. closing of G1. This letter transmits the Inservice Inspection Summary Report as required by paragraph IWA-6230 of Section Xl.

Two separate ASME Section Xl inservice examination programs are implemented at the KNPP.

One program is for pressure retaining piping/vessel and component supports and the other program for the metal containment. The 2003 refueling outage constituted the second inspection year of the third period of the third interval for the piping/vessel and component support program. The 2003 refueling outage was also the second inspection year of the second period of the first interval for the metal containment program. Examinations for the piping/vessel and component support program were performed in accordance with the ASME Boiler and Pressure Vessel Code Section Xl 1989 Edition. Examinations for the metal containment program were performed in accordance with the 1992 Edition up to and including the 1992 Addenda of Section Xl of the ASME Boiler and Pressure Vessel Code. These requirements were implemented in accordance with the "Kewaunee Nuclear Power Plant Third Ten-Year Inservice Inspection (ISI) Program 1994-2004," "Kewaunee Nuclear Power Plant First 10-Year Inservice Inspection Class MC (ISI) Program 1996-2006," Plant Technical Specifications, and nondestructive examination procedures.

N490 Highway 42

  • Kewaunee, Wisconsin 54216-9510 Telephone: 920.388.2560

Docket 50-305 NRC-03-082 August 6, 2003 Page 2 The following items were examined for Class 1, Class 2, Class 3 Components, and their supports:

1. Reactor Vessel Control Rod Drive Mechanisms and 3/4" Head Vent Line
2. Regenerative Heat Exchanger Tubesheet to Shell Weld
3. Reactor Coolant Pump Main Flange Bolting, Flange Surfaces, and No. 1 Seal Housing Bolting
4. Reactor Coolant Pump External Casing Weld and Casing Internal Surfaces
5. Reactor Coolant Pump Flywheel
6. Class 1 and Class 2 Piping Welds
7. Class 1, Class 2, Class 3 Piping and Component Supports and Hangers
8. Class 1 and Class 2 Reactor Vessel Conoseal Bolting, Steam Generator Primary Side Manway Bolting, Pressurizer Manway Bolting, Flange Bolting, and Valve Bonnet Bolting
9. Preservice Examination of Class 1 Reactor Coolant Pump Main Flange Bolt
10. Preservice Examination of Class 1 Piping Welds
11. Preservice Examination of Class 1 Valve Bonnet Bolting
12. Preservice Examination of Component Cooling Water Heat Exchangers 1A and 1B Supports
13. Accumulator Tanks 1A and 1B 2", 1," and 3/" Coupling Base Metal
14. Class 1 System Leakage Test
15. Class 2 and Class 3 System Inservice and Functional System Pressure Tests The following items were examined for the Class MC Reactor Building Containment Vessel:
1. Accessible Surface Areas
2. Circumferential Weld
3. Containment Penetration Bellows
4. Airlocks
5. Seals and Gaskets The following items were examined in accordance with Kewaunee Nuclear Power Plant Technical Specifications:
1. Eddy Current Testing of Steam Generators In addition, the following examinations were performed in excess of ASME Boiler and Pressure Vessel Code Section Xi 1989 Edition Requirements and included:
1. Portions of the Service Water System were radiographed for wall loss, pits, nodules, and sand, mud or other sediments
2. Balance of plant piping subject to erosion/corrosion was examined by radiographic, ultrasonic, and visual techniques
3. Nuclear Regulatory Commission Order EA-03-009-lssuance of Order Establishing Interim Inspection Requirements For Reactor Pressure Vessel Heads at Pressurized Water Reactors

Docket 50-305 NRC-03-082 August 6, 2003 Page 3 Please find attached a copy of the following documentation that summarizes the inservice inspection activities and results for the Kewaunee Nuclear Power Plant 2003 Refueling Outage.

1. Summary of recordable indications and a description of how they were dispositioned (Attachment 1)
2. Summary of Class 1 and 2 Repairs and Replacements of Components 1 inch in diameter or smaller (Attachment 2)
3. Form NIS-1 Owners Report for Inservice Inspections of Class 1, Class 2, and Class 3 Components (Attachment 3)
4. Form NIS-1 Owners Report for Inservice Inspections for Class MC Components (Attachment 4)
5. Form NIS-2 Owner's Report for Repair or Replacements (61 Total) (Attachment 5)
6. Examination Summary for Scheduled and Augmented Inservice Inspection (ISI) Program (Attachment 6)
7. Examination Summary for Inservice Inspection (ISI) Class MC Program (Attachment 7)
8. Examination Summary for Steam Generator Eddy Current (Attachment 8)
9. Examination Summary for Nuclear Regulatory Commission Order EA-03-009 (Attachment 9)
10. A summary of examinations which were limited by geometric, metallurgical, or design/access restrictions and their associated data sheets (Attachment 10)

The final reports for each of these examinations are on file in the QA/QC Records Vault at the Kewaunee Nuclear Power Plant. These records are available for review as deemed necessary.

Additional Comments The next Refueling Outage at the Kewaunee Nuclear Power Plant is tentatively scheduled for September 2004.

Thomas Coutu Site Vice-President, Kewaunee Plant PEB Attachment cc - U.S. NRC - Region IlIl (w/o attach)

U.S. NRC - Senior Resident Inspector (w/o attach)

ATTACHMENT 1 NUCLEAR MANAGEMENT COMPANY, LLC KEWAUNEE NUCLEAR PLANT DOCKET 50-305 August 6, 2003 Letter from Thomas Coutu (NMC)

To Document Control Desk (NRC)

Summary of Recordable Indications and Description of Disposition

Docket 50-305 NRC-03-082 August 6, 2003 , Page 1 TABLE 1 TYPE OR LOCATION OF RECORDABLE INDICATION METHOD NO. OF RI'S (RI) l M.

Reactor Vessel Conoseal Bolting Visual (VT-3) 2 Conoseals Steam Generator Primary Manway Bolting Visual (VT-I) 1 Stud 2" Piping Socket Weld Surface (PT) 1 Weld Component Supports and Hangers Visual (VT-3) 12 Supports Piping Flange Bolting Visual (VT-3) 3 Flanges Valve Bonnet Bolting Visual (VT-3) 6 Valves System Pressure Tests Visual (VT-2) 16 Items Disposition of Class 1, Class 2, and Class 3 indications have been completed in accordance with the rules of ASME Boiler and Pressure Vessel Code Section Xl 1989 Edition and ASME Boiler and Pressure Vessel Code Section Xl 1992 Edition up to and including 1992 Addenda for Class MC Components. Applicable codes, standards, and engineering criteria were used to disposition indications associated with the non-code-required examinations. Recordable indications for Class 1, Class 2, Class 3 and Class MC have been dispositioned as summarized below:

1. A 0.375" long linear indication (identified as a forging lap) on 2" socket weld RTD-W70S was recorded during performance of liquid penetrant examinations. This Linear Indication was unacceptable per ASME Boiler and Pressure Vessel Code Section Xl 1989 Edition Table IWB-3514-2. The linear indication was reduced in size under work order 03-004115 by light filing with a small file, reexamined and accepted with a 0.100" linear acceptable ASME Boiler and Pressure Vessel Code Section Xl 1989 Edition Table IWB-3514-2 indication.
2. Visual (VT-1, VT-2, and VT-3) indications recorded on reactor vessel conoseal bolting, steam generator primary side manway bolting, piping flange bolting, valve bonnet bolting, component and piping supports and hangers during system pressure tests were:

(1) evaluated and accepted, or (2) repaired, reexamined and accepted by: Nuclear Management Company, LLC; Maintenance, Quality Control, Engineering and Technical Support, or Inservice Inspection Personnel and reviewed by the Authorized Nuclear Inservice Inspector.

ATTACHMENT 2 NUCLEAR MANAGEMENT COMPANY, LLC KEWAUNEE NUCLEAR PLANT DOCKET 50-305 August 6, 2003 Letter from Thomas Coutu (NMC)

To Document Control Desk (NRC)

Summary of Class 1 and 2 ReDairs and Replacement of Components 1 inch in Diameter of Smaller

Docket 50-305 NRC-03-082 August 6, 2003 , Page 1 The following summarizes the repairs and replacements performed following the 2001 Refueling Outage and during the 2003 Refueling Outage by grinding, buffing, filing, cutting, or welding on the Class 1 and Class 2 pressure boundary. These repairs and replacements are in addition to those itemized on the attached Forms "NIS-2 Owner's Report for Repairs or Replacements."

Comronent Class Reference Reeair/Replacement Method

/2 Rupture Disc. XK-100-18 Welding of Replacement Rupture Disc.

ATTACHMENT 3 NUCLEAR MANAGEMENT COMPANY, LLC KEWAUNEE NUCLEAR PLANT DOCKET 50-305 August 6, 2003 Letter from Thomas Coutu (NMC)

To Document Control Desk (NRC)

Form NIS-1 Owner's Report for Inservice Inspections of Class 1, Class 2, and Class 3 Components

Page 1 of 10 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16, 1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Reactor Vessel RV Combustion CE69202 U11480 21010 Engineering Pressurizer PZR Westinghouse 1151 U11402 68-23 Steam Generator SG- Westinghouse/ 1141/0202 U11400 68-28/151 1A Ansaldo Energia Milano Steam Generator SG- Westinghouse/ 1142/0201 U11401 68-29/150 1B Ansaldo Energia Milano Excess Letdown Heat Sentry 3996-5E U11407 364 Exchanger AHEL-1A Excess Letdown Heat Sentry 3996-6E U11408 365 Exchanger AHEL-IB Class 1 Piping Texas Pipe Bending Reactor Coolant Westinghouse 1A-1-618J871-Pump RCP-1A GO1 Reactor Coolant Westinghouse 1B-2-618J871-Pump RCP-1B G02

Page 2 of 10 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16,1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Residual Heat Joseph Oat and 1817-1E U11046 344 Exchanger Sons AHRS1-1A Residual Heat Joseph Oat and 1817-1F U11424 345 Exchanger Sons AHRS2-1B Charging Pump Greer Hydraulics GNI-1848 Pulsation Dampener APD-1A Charging Pump Greer Hydraulics GNI-1846 Pulsation Dampener APD-1B Charging Pump Greer Hydraulics GNI-1847 Pulsation Dampener APD-1C Seal Water Heat Atlas 734 U11404 596 Exchanger AHSW Volume Control Tank Joseph Oat and 1787-1C U11425 376 VCT Sons Regenerative Heat Joseph Oat and 1831-13 U11409 413 Exchanger ARG Sons U11410 414 U11411 415

Page 3 of 10 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16,1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Letdown Heat Atlas 1206 U11405 1031 Exchanger AHLD Seal Water Injection Commercial 101072 1172 Filter AFSI-1A Filters Seal Water Injection Commercial 101073 1173 Filter AFSI-1B Filters Reactor Coolant AMF Cuno 121 2616 Filter AFRC Seal Water Filter AMF Cuno 123 2618 AFSW Class 2 Piping Texas Pipe Bending Charging Pump Ajax Iron Works 6578 APCH-1A Charging Pump Ajax Iron Works 6576 APCH-1B Charging Pump Ajax Iron Works 6577 APCH-1C Charging Pump Greer Hydraulics GH1-10234 568 APCH-1A Suction Stabilizer

Page 4 of 10 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO.1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16,1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Charging Pump Greer Hydraulics GH1-10235 569 APCH-1B Suction Stablizer Charging Pump Greer Hydraulics GH1-10236 570 APCH-1C Suction Stablizer Residual Heat Byron Jackson 681N0277 Removal Pump APRH1-1A Residual Heat Byron Jackson 681N0276 Removal Pump APRH2-1B Refueling Water General American C-8297/1969 Storage Tank Transportation Company Diesel Generator ITT Standard 750797-01-2 AHDG-1A Cooling Corp. &

Water Exchangers (2) 750797-01-3 Diesel Generator ITT Standard 750797-01-1 AHDG-1B Cooling Corp. &

Water Exchangers (2) 750797-01-4

Page 5 of 10 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16,1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Auxiliary Feedwater Pacific Pump 46573 Pump APFM-1A Motor Driven Auxiliary Feedwater Pacific Pump 46574 Pump APFM-1B Motor Driven Auxiliary Feedwater Pacific Pump 46575 Pump APFT Turbine Driven Reactor Coolant Perfex 723701-1 4014 Pump RCPC-1A Corporation Lube Oil Cooler Reactor Coolant Perfex 723701-2 4015 Pump RCPC-1B Lube Corporation Oil Cooler Class 3 Piping Texas Pipe Bending Containment Fan Joy GF14402 Cooler AHCF-1A Manufacturing and American Air Filter

Page 6 of 10 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16, 1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Containment Fan Joy GF14399 Cooler AHCF-1B Manufacturing and American Air Filter Containment Fan Joy GF14401 Cooler AHCF-1C Manufacturing and American Air Filter Containment Fan Joy GF14400 Cooler AHCF-1D Manufacturing and American Air Filter Safety Injection Pump Bingham Pump 290696 APSI-1A Safety Injection Pump Bingham Pump 290697 APSI-1B Safety Injection Pump Thermxchanger X10199A2 Lube Oil Cooler AHSC-1A Safety Injection Pump Thermxchanger X10199A3 Lube Oil Cooler AHSC-1B

Page 7 of 10 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16,1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Safety Injection Pump Borg Warner 854030:854030 Heat Exchangers (2)

AHSC-1A Safety Injection Pump Borg Warner 854030:854030 Heat Exchangers (2)

AHSC-1B Residual Heat Borg Warner 681N0276 Removal Pump AHRHRP-1A Shaft Seal Heat Exchanger Residual Heat Borg Warner 681N0276 Removal Pump AHRHRP-1B Shaft Seal Heat Exchanger Accumulator Tank Wyatt H-5645-69 U11397 ACC-1A Accumulator Tank Wyatt H-5644-69 U11398 ACC-1B Containment Spray Ingersoll Rand 0670-74 Pump APCS-1A

Page 8 of 10 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16,1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Containment Spray Ingersoll Rand 0670-75 Pump APCS-1B Containment Spray Helliflow 49486938 Pump APCS-1A Gland Seal Cooler Containment Spray Helliflow 6080694 Pump APCS-1B Gland Seal Cooler Component Cooling Ingersoll Dresser 0600009 Pump APCC-1A Pump Flow Serv.

Component Cooling Ingersoll Dresser 0600010 Pump APCC-1B Pump Flow Serv.

Service Water Pump Worthington VTP27737 APSW-1A1 Pump Service Water Pump Worthington 75 TU-1719-1 APSW-1A2 Pump Service Water Pump Worthington VTP27736 APSW-1B1 Pump Service Water Pump Worthington VTP27738 APSW-1B2 Pump

Page 9 of 10 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16,1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Spent Fuel Pool Heat Struther Wells 1-68-06-1519 U11445 Exchanger AHSF Main Steam Moisture Wright Austin 6230 X.R. 6008 Separator Spent Fuel Pool Pump Gould Pumps 786A519.1 APSF-1A Spent Fuel Pool Pump Gould Pumps 786A519.2 APSF-1B Service Water Pump S.P. Kinney 2278 Strainer ASSW-1A1 Engineers Service Water Pump S.P. Kinney 2279 Strainer ASSW-1A2 Engineers Service Water Pump S.P. Kinney 2280 Strainer ASSW-1B1 Engineers Service Water Pump S.P. Kinney 2281 Strainer ASSW-1B2 Engineers Component Cooling Engineers and S-26125 U39499 3269 Heat Exchanger Fabricators Co.

AHCC1-1A

Page 10 of 10 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16, 1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Component Cooling Engineers and S-26126 U39500 3270 Heat Exchanger Fabricators AHCC2-1B Component Cooling Sharpsville Steel 714 U11421 714 Surge Tank ATCS Control Room Air Trane Company K11H202002 Conditioning Unit 1A Coil Control Room Air Trane Company K11H202003 Conditioning Unit 1B Coil Control Room Air ITT Bell and Gossett Conditioning Expansion Tank 1A Control Room Air ITT Bell and Gossett 116013 Conditioning Expansion Tank 1B

FORM NIS-1 (Back)

8. Examination Dates: May 8, 2002 to May 11, 2003
9. Inspection Period Identification: 3rd
10. Inspection Interval Identification: 3rd
11. Applicable Edition of Section XI: 1989 Addenda: None
12. Date/Revision of Inspection Plan: November 27, 2000/Revision 2
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. Reference Tab C
14. Abstract of Results of Examinations and Tests. Reference Tab B and Tab F
15. Abstract of Corrective Measures. Reference Tab B and Tab F Utilization of ASME Boiler and Pressure vessel Code Section XI: Code Cases: N-416-1, N-416-2, N-460, N-48 1, N-49 1, N-498 and N-498- 1.

We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (If applicable): /V14 Expiration Date: Ho Date: St4 a Zy 23 20 Q93 Signed: WGconi. PAlti SeevJe By:

Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of £daseeo'SJ.. and employed by i44er$e eb r64 ,, o1.r- -r of W4,e eg C r. have inspected the components described in this Owner's Report during the period A yf4v 8 Rev to MuAy /, 0403 , and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspction.

W 4A, Commissions A'S77s/

7 iJ1s/0o02 Xs

.5. A

/ Inspfctor's Signature National Board, State. Province, and Endorsements Date: A14,f 23 20 &.3 I

ATTACHMENT 4 NUCLEAR MANAGEMENT COMPANY, LLC KEWAUNEE NUCLEAR PLANT DOCKET 50-305 August 6, 2003 Letter from Thomas Coutu (NIMC)

To Document Control Desk (NRC)

Form NIS-1 Owner's ReDort for Inservice Inspections for Class MC Comoonents

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16,1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Reactor Building Chicago Bridge C4454 U11423 ...

Containment Vessel and Iron Company Personnel Airlock Chicago Bridge C4454 U11423 ---

and Iron Company

FORM NIS-1 (Back)

8. Examination Dates: April 5, 2003 to May 11, 2003
9. Inspection Period Identification: 2nd
10. Inspection Interval Identification: 1st
11. Applicable Edition of Section XI: 1992 Addenda: 1992
12. Date/Revision of Inspection Plan: September 25, 2000/Revision 1
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. Reference Tab C
14. Abstract of Results of Examinations and Tests. Reference Tab B and Tab F
15. Abstract of Corrective Measures. Reference Tab B and Tab F We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (If appli A/A Expiration Date: Am4 Date: A4aY 2 3 20 o 3 Signed: PXAi, lc rse By:

Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of 6 and employed by 9.4,ereroC t Sg4o" /j3w (i, Cr of

  1. 40cretaf C7 . have inspected the components described in this Owner's Report during the period Apttc T. 2zo 3 to AlAy go 20o03 ,and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspectn.

___ /1 Commissions 1e-zdi2/ gJis/~oozj( zs A

/ Inspector's 3tgnature National Board, State. P~roince, ahd Endorsements Date: 414 2 3 20 v3

ATTACHMENT 5 NUCLEAR MANAGEMENT COMPANY, LLC KEWAUNEE NUCLEAR PLANT DOCKET 50-305 August 6, 2003 Letter from Thomas Coutu (NMC)

To Document Control Desk (NRC)

Form NIS-2 Owner's Report for Repair or Replacement (61 Total)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 3/6/2003 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 01-011101
3. Work Performed By Nuclear Management Companv, LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 02 Class 3 SERVICE WATER Expiration Date NA
5. (a) Applicable Construction Code B16.34 Code Case N-416-1 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped SW-1041A-2 CONBRACO INDUSTRIES NA NA SW 134-217 2002 REPLACEMENT N INC.
7. Description of Work INSTALL NEW CLASS 3 AIR CONDITIONING COOLING WATER SYSTEM 2 1/2' VALVE SW-1041A-2, 2 - 2 1/2" FLANGES AND 2 -2 1/2" BUTT WELDS.
8. Tests conducted Hydrostatic g Pneumatic g Nominal Operating Pressure p Exempt n Other EJ Pressure 69 psi Test Temp. 40 deg. F
9. Remarks UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SECTION XI: CODE CASE N-416-1.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 3/6/2003 Name of Component: SW-1041A-2 Work Order Number: 01-011101 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed C.A f4 M L,

  • Date god .20 Q3 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period ,,1-/- O to G-"'3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described inthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspectors Signature National Board, State, Province, and Endorsements Date 6 - lo 20o 3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/13/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Unit No. I
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 01-016562
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 34 Class 2 RESIDUAL HEAT REMOVAL Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped RHR-F3 NF NA NA NA 1967 REPAIRED N
7. Description of Work REPAIR LEAK ON CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM 10 SUCTION FLANGE RHR-F3.
8. Tests conducted Hydrostatic Pneumatic r] Nominal Operating Pressure [x] Exempt n Other [ Pressure 375 psi Test Temp. 112 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/13/2003 Name of Component: RHR-F3 Work Order Number: 01-016562 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed bAf4C. L;kOMuAA l Date ,20 03 Owner or Owners Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owners Report during the period . /-OZ to C - -03, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

go G o -iature Commissions NB7741, I, N, IS, A WIS 100024 Inspec s Signature National Board, State, Province, and Endorsements Date 64 - /a 20 0

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation Date 4/25/2003 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 01-022099
3. Work Performed By Nuclear Management Company, LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 34 Class 2 RESIDUAL HEAT REMOVAL Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped l

FE- VICKERY-SIMMS NF NA 27020 1970 REPAIRED N 626 INC.

7. Description of Work REPAIR DUE TO LEAKAGE CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM 10" FLANGE FE-626.
8. Tests conducted Hydrostatic 2 Pneumatic Nominal Operating Pressure 1-3 Exempt n Other [n Pressure .150 psi Test Temp. 93 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 4/25/2003 Name of Component: FE-626 Work Order Number: 01-022099 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed 0 eAh CW AC4v & Date ,20 a 3 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period A -/-dZ to 6 -A -°3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspectors Signature National Board, State, Province, and Endorsements Date C - /0 ,20 CO,3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Cormoration Date 5/13/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-003489
3. Work Performed By Nuclear Management ComDany. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 34 Class 2 RESIDUAL HEAT REMOVAL Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. DD Built Replacement Stamped RHR-3B CRANE NF NA AC034-002 1972 REPAIRED N COMPANY
7. Description of Work REPAIR BONNET TO BODY LEAK ON CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM 8 VALVE RHR-3B.
8. Tests conducted Hydrostatic Dl Pneumatic U Nominal Operating Pressure f77 Exempt U Other El Pressure 375 psi Test Temp. 112 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/1 3/2003 Name of Component: RHR-3B Work Order Number: 02-003489 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed Gil & idhA 1AUV 4 G~Lln 60t6v Date e ,20 Qk Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owners Report during the period o? -1 2 to __-_-__3_, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspects Signature National Board, State, Province, and Endorsements Date 6 -/0 ,20 CZ

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 9/24/2002 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-004201
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 35 Class 2 CHEMICAL AND VOLUME CONTROL Expiration Date NA
5. (a)Applicable Construction Code SEC. Vil DIV.1-1975 Code Case NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped APD-1C GREER GHI-1849 NA 07002 1975 REPLACEMENT Y HYDRAULICS
7. Description of Work REPLACE DAMPENER SPRING ON CLASS 2 CHEMICAL AND VOLUME CONTROL SYSTEM CHARGING PUMP iC PULSATION DAMPENER.
8. Tests conducted Hydrostatic Cl Pneumatic F] Nominal Operating Pressure M Exempt LI Other n Pressure 2240 psi Test Temp. 114 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 9/2412002 Name of Component: APD-1 C Work Order Number: 02-004201 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed A £JtWJOli/

4 Date 4 , .20 03 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period o2-/-O 2 to 4 ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

/7 sh ^ - - Commissions NB7741, I, N. IS, A WIS 100024 Inspectors Signature National Board, State, Province, and Endorsements Date 6 -/0 ,20 CZ3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation Date 9/24/2002 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 02-004262
3. Work Performed By Nuclear Manaaement Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 35 Class 2 CHEMICAL AND VOLUME CONTROL Expiration Date NA
5. (a) Applicable Construction Code SEC. VIII DIV.1-1 975 Code Case NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped APD-1A GREER GHI-1848 NA 07000 1975 REPLACEMENT Y HYDRAULICS
7. Description of Work REPLACE DAMPENER SPRING ON CLASS 2 CHEMICAL AND VOLUME CONTROL SYSTEM CHARGING PUMP lA PULSATION DAMPENER.
8. Tests conducted Hydrostatic [] Pneumatic U Nominal Operating Pressure M Exempt C Other [] Pressure 2240 psi Test Temp. 114 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 9/24/2002 Name of Component: APO-1A Work Order Number: 02-004262 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed 1 f f i 7 &X/rw Date ,20 03 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford. CT have inspected the components described in the Owners Report during the period - -/-O'Z to c 4 -a03, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspector's Signature National Board, State, Province, and Endorsements Date 6 - /o ,20 d'-3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation Date 8/21/2002 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet I of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-004263
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 35 Class 2 CHEMICAL AND VOLUME CONTROL Expiration Date NA
5. (a)Applicable Construction Code SEC. VIII DIV.1-1975 Code Case NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped APD-11B GREER GHI-1846 NA 07001 1975 REPLACEMENT Y HYDRAULICS
7. Descripion of Work REPLACE DAMPENER SPRING ON CLASS 2 CHEMICAL AND VOLUME CONTROL SYSTEM CHARGING PUMP 1B PULSATION DAMPENER.
8. Tests conducted Hydrostatic L Pneumatic El Nominal Operating Pressure [ 3 Exempt :

Other  :] Pressure 2240 psi Test Temp. 115 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 8/21/2002 Name of Component: APD-IB Work Order Number: 02-004263 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed e 0 LU &bLAJ Date 4 ,20 ai Owner or Owner's Designee. Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period A '/-OZ to 6 ' -03, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS i10024 Inspector's Signature National Board, State, Province, and Endorsements Date 6e-O ,20 03

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/113/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-007269
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 23 Class 2 CONTAINMENT SPRAY Expiration Date NA
5. (a)Applicable Construction Code B16.5-1967 Code Case NA (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped CI-1003 WILLIAM POWELL NF NA ICS022-001 1968 REPAIRED N CO.
7. Description of Work OPEN FOR INSPECTION CLASS 2 INTERNAL CONTAINMENT SPRAY SYSTEM 2" VALVE CI-1003.
8. Tests conducted Hydrostatic [] Pneumatic [1 Nominal Operating Pressure E3 Exempt n Other n Pressure 17.3 psi Test Temp. 78 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/13/2003 Name of Component: Cl-1003 Work Order Number: 02-007269 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed B4,cp A 6ZLilt1I, Date t r 20 0 3 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owners Report during the period j- . to 66- - -p3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspectors Signature National Board, State, Province, and Endorsements Date & -/O 20 03

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/9/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-007295
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 36 Class 1 REACTOR COOLANT Expiration Date NA
5. (a)Applicable Construction Code ASME ill-1 968 Code Case NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped PR-3B CROSBY, ASHTON GAGE NF NA RC008-002 1972 REPAIRED N COMPANY
7. Description of Work REMOVE CLASS 1 REACTOR COOLANT SYSTEM 6 VALVE PR-3B FOR SETPOINT TESTING.
8. Tests conducted Hydrostatic LI Pneumatic LI Nominal Operating Pressure Rl Exempt [L Other E1 Pressure 2240 psi Test Temp. 543 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/9/2003 Name of Component: PR-3B Work Order Number: 02-007295 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed _____ Date 4 20 o3 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period  : /-02 to 6 -' ° and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 1nqnsctonr' Rinnature National Board, State, Province, and Endorsements Date 6 - /0 ,20 0

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/20/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-007418
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 35 Class 2 CHEMICAL AND VOLUME CONTROL Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ED Built Replacement Stamped CVC-10 KEROTEST MFG NV-143 NA CS100-005 1973 REPAIRED N CORP
7. Description of Work OPEN FOR INSPECTION CLASS 2 CHEMICAL AND VOLUME CONTROL SYSTEM 2" VALVE CVC-10.
8. Tests conducted Hydrostatic [ Pneumatic [] Nominal Operating Pressure [x] Exempt [

Other LI Pressure 2245 psi Test Temp. 548 deg.F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/20/2003 Name of Component: CVC-10 Work Order Number: 02-007418 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed CPX J1 &M,2"V &LM/l Date 20 03 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period '1 -IO to 4 -6 03, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

,_z' G oet-~ - Commissions NB7741, I, N. IS, A WIS 100024 Inspectors Signature National Board, State, Province, and Endorsements Date t- /° , 20 03

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/13/2003 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2 Kewaunee Nuclear Power Plant Unit No. 1
2. Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-007419
3. Work Performed By Nuclear Management Company, LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 35 Class 1 CHEMICAL AND VOLUME CONTROL Expiration Date NA
5. (a)Applicable Construction Code B31.1-1967 Code Case NA (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped CVC-205B KEROTEST NU321 NA CS100-001 1973 REPAIRED N MANUFACTURING
7. Description of Work OPEN FOR INSPECTION CLASS 1 CHEMICAL AND VOLUME CONTROL SYSTEM 2" VALVE CVC-205B.
8. Tests conducted Hydrostatic n Pneumatic n Nominal Operating Pressure 3 Exempt LI Other [ Pressure 2240 psi Test Temp. 543 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/13/2003 Name of Component: CVC-205B Work Order Number: 02-007419 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed get "O I4l aaJ4 &WL Date .20 a Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period c} '/- 1' . to / Al, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

& _ 7 1*1,_ .Commissions NB7741, I, N, IS, A WIS 100024 InspectoFsSignature National Board, State, Province, and Endorsements Date 6-/0 ,20 03

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/13/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-900t Sheet 1 of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-007420
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 35 Class 1 CHEMICAL AND VOLUME CONTROL Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped CVC-206A KEROTEST NF NA CS100-004 1973 REPAIRED N MANUFACTURING
7. Description of Work OPEN FOR INSPECTION CLASS 1 CHEMICAL AND VOLUME CONTROL SYSTEM 2" VALVE CVC-206A.
8. Tests conducted Hydrostatic 2 Pneumatic n Nominal Operating Pressure 3 Exempt 1 Other El Pressure 2240 psi Test Temp. 543 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/13/2003 Name of Component: CVC-206A Work Order Number: 02-007420 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed (e' IIM 0 Date i .20 03 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owners Report during the period .7 - /- A to 6~ -' °3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

^- XL Commissions NB7741, I, N, IS, A WIS 100024 Inspector's Signature National Board, State, Province, and Endorsements Date 6/O - 0 3 ,20 O 3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/13/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-007421
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 35 Class 1 CHEMICAL AND VOLUME CONTROL Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped CVC-206B KEROTEST NU139 NA CS 100-003 1973 REPAIRED N MANUFACTURING
7. Description of Work OPEN FOR INSPECTiON CLASS 1 CHEMICAL AND VOLUME CONTROL SYSTEM 2" VALVE CVC-206B.
8. Tests conducted Hydrostatic D Pneumatic Nominal Operating Pressure [23 Exempt l Other [] Pressure 2240 psi Test Temp. 543 deg. F
9. Remarks NOT APPLICABLE Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/13t2003 Name of Component: CVC-206B Work Order Number: 02-007421 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed Ca eAA cb~u? 6l Date 6 4 2003 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owners Report during the period J -/ - ° Z to 6 6 -. 3 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 U Inspectorlsignature National Board, State, Province, and Endorsements Date 6- /4p ,20 O3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corooration Date 5/9/2003 700 North Adams P.O.Box 19001 Green Say. WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-007509
3. Work Performed By Nuclear Management Comoany. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 36 Class 1 REACTOR COOLANT Expiration Date NA
5. (a) Applicable Construction Code SEC. III-1987 ADD. Code Case NA (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ED Built Replacement Stamped SG-1A- ANSALDO ENERGIA 0202 151 00035 2000 REPLACEMENT N HLMWB MILANO 7I.~O.a~II I. ,nf -l W-rL, Vl

-tb~lplI- -1 09OI rroAvx aV', r~i AQQ I was, REACTOR COOLANT SYSTEM STEAM GENERATOR 1A HOTLEG MANWAY STUD (1)

8. Tests conducted Hydrostatic D Pneumatic n Nominal Operating Pressure nX Exempt Other n Pressure 2240 psi Test Temp. 543 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/9/2003 Name of Component: SG-1A-HLMWB Work Order Number: 02-007509 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed )% ggi e. )PAO LO &&bi Date L .

,20 o3 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described inthe Owner's Report during the period e -/%O to L -Z -L , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report inaccordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described Inthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable inany manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

t_ _ _ _ _ _ Commissions NB7741, I, N, IS,A WIS 100024 Inspector's Signature National Board, State, Province, and Endorsements Date eV /° 20 OJ3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/9/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Kewaunee Nuclear Power Plant Unit No. 1
2. Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-007509
3. Work Performed By Nuclear Manaaement Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 36 Class 1 REACTOR COOLANT Expiration Date NA
5. (a)Applicable Construction Code SEC.111-1987 ADD. Code Case NA (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped SG-1A- ANSALDO ENERGIA 0202 151 00035 2000 REPLACEMENT N CLMWB MILANO
7. Description of Work REPLACE CLASS 1 REACTOR COLLANT SYSTEM STEAM GENERATOR lA COLDLEG MANWAY STUDS (21 AND 1 MANWAY NUT..
8. Tests conducted Hydrostatic n Pneumatic a Nominal Operating Pressure pi Exempt LI Other 1I Pressure 2240 psi Test Temp. 543 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 519/2003 Name of Component: SG-1A-CLMWB Work Order Number: 02-007509 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed &flv C0IXV

&Aaa/n0h2it Date 6n.L4,20 a Owner or Owners Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owners Report during the period c(; /-1-OX to & -' -O'3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspectors Signature National Board, State, Province, and Endorsements Date 6 - /O ,20 03

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation Date 5/9/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-007509
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 36 Class 1 REACTOR COOLANT Expiration Date NA
5. (a) Applicable Construction Code SEC. 111-1987 ADD Code Case NA (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ED Built Replacement Stamped SG-1 B- ANSALDO ENERGIA 0201 150 00036 2000 REPLACEMENT N HLMWB MILANO
7. Description of Work REPLACE CLASS 1 REACTOR COOLANT SYSTEM STEAM GENERATOR I1 HOT LEG MANWAY NUT.
8. Tests conducted Hydrostatic n Pneumatic El Nominal Operating Pressure R Exempt []

Other [1 Pressure 2240 psi Test Temp. 543 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/9/2003 Name of Component: SG-1 B-HLMWB Work Order Number: 02-007509 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed ° CCirnvtl, Date ,20 0 k Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owners Report during the period a2 -/-02 to 4 - -03, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Signature Inspector's National Board, State, Province, and Endorsements Date 6 -/0 ,2o 3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/9/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-007509
3. Work Performed By Nuclear Management Company, LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 36 Class 1 REACTOR COOLANT Expiration Date NA
5. (a) Applicable Construction Code SEC. 1l1-1 987 ADD. Code Case NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped SG-1 B- ANSALDO ENERGIA 0201 150 00036 2000 REPLACEMENT N CLMWB MILANO
7. Description of Work REPLACE CLASS 1 REACTOR COOLANT SYSTEM STEAM GENERATOR 18 COLD LEG MANWAY STUD (1) AND 4 MANWAY NUTS.
8. Tests conducted Hydrostatic [] Pneumatic [] Nominal Operating Pressure EJ Exempt D Other n Pressure 2240 psiii Test Temp. 543 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/9/2003 Name of Component: SG-1B-CLMWB Work Order Number 02-007509 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed e A : . P 0ALWrf Date 4 20 0 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owners Report during the period A?-/ -03 to ; -' -t-3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspector's ignature National Board, State, Province, and Endorsements Date 6- /O ,20 0k3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/30/2002 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nudear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-007734
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 21 Class 2 SPENT FUEL POOL COOLING Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped FPC-1100 ITT GRINNEL VALVE NF NA FPCO07-00 1970 REPLACEMENT N COMPANY
7. Description of Work REPLACE DIAPHRAGM ON CLASS 2 SPENT FUEL POOL COOLING AND CLEAN-UP SYSTEM 2" VALVE FPC-1100.
8. Tests conducted Hydrostatic [] Pneumatic j1 Nominal Operating Pressure M Exempt R Other [ Pressure 64 ps;i Test Temp. 60 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/30/2002 Name of Component: FPC-1100 Work Order Number. 02-007734 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed I9L4 l pZ d4tW Date .20 d Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owners Report during the period on -/-O.Z to G -6 0-, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described inthis Owners Report inaccordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described inthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4 1 <>aL-* Commissions NB7741, I, N, IS,A WIS 100024 Inspector's signature National Board, State, Province, and Endorsements Date C' /° ,2o0°3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/9/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 02-008856
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 36 Class 1 REACTOR COOLANT Expiration Date NA
5. (a)Applicable Construction Code NA Code Case NA (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ED Built Replacement Stamped RCP-1A WESTINGHOUSE 1-618J871-GO1 NA 00037 1970 REPLACEMENT N
7. Description of Work REPLACE CLASS 1 REACTOR COOLANT PUMP lA SHAFT. INTERNALS. SEAL PACKAGE AND MOTOR INCLUDING FLANGE CONNECTIONS TO CLASS 1 SEAL WATER CVC SYSTEM (3 TOTAL). CLASS 3 COMPONENT COOLING WATER SYSTEM (2 TOTAL ) AND REPLACE ONE REACTOR COOLANT MAIN FLANGE BOLT.
8. Tests conducted Hydrostatic [ Pneumatic [] Nominal Operating Pressure Exempt Ln Other [] Pressure 2240 psi Test Temp. 543 deg.F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/9/2003 Name of Component: RCP-1A Work Order Number: 02-008856 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed # C4 &~WX~MbJM/2L~6fl7 g l ~  ; o t tdDate ) .j2003 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owners Report during the period - - / -0 .L to (6 -' -0.3 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described inthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

< ~ Commissions NB7741, I, N, IS, A WIS 100024 Inspectors ynature National Board, State, Province, and Endorsements Date (6 "/0 ,20 0 3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corvoration Date 5/9/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-008856
3. Work Performed By Nuclear Manaoement Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. identification of System 35 Class 1 CHEMICAL AND VOLUME CONTROL Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped CVC-F2 WESTINGHOUSE NA NA NA 1967 REPLACEMENT N
7. Description of Work REPLACE DAMAGED STUD ON CLASS 1 CHEMICAL AND VOLUME CONTROL SYSTEM 1 1/2" FLANGE CVC-F2.
8. Tests conducted Hydrostatic n Pneumatic n Nominal Operating Pressure m Exempt n Other [] Pressure 2240 psii Test Temp. 543 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/9/2003 Name of Component: CVC-F2 Work Order Number 02-008856 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed &°&4VX& 7g4W&& Oaka 6omr~v Date a .;20 03 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period ' -/-0J- to 6 -' s°3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described inthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspectors Signature National Board, State, Province, and Endorsements Date 6 °,20 03

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corooration Date 5/1312003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-009750
3. Work Performed By Nuclear Management Comoany. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 05B Class 2 AUXILIARY FEEDWATER Expiration Date NA
5. (a)Applicable Construction Code B1 6.34 Code Case N-416-1 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped AFW-4B FLOWSERVE AV-169 NA F015-002 2003 REPLACEMENT N CORP.
7. Description of Work REPLACE CLASS 2 AUXILARY FEEDWATER SYSTEM 3" VALVE AFW-4B AND 2- 3" BUTT WELD.
8. Tests conducted Hydrostatic [] Pneumatic z Nominal Operating Pressure pI Exempt EL Other [] Pressure 963 psi Test Temp. 98 deg. F
9. Remarks UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SECTION XI: CODE CASE N-416-1.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/13/2003 Name of Component: AFW-4B Work Order Number: 02-009750 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed b 2 ZA grZ Date IL,20 .L 1L Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period A- / -° 2 to 6 - s°3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspector' ignature National Board, State, Province, and Endorsements Date 6 /° ,20 03

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/13/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-009751
3. Work Performed By Nuclear Manaaement Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 05B Class 2 AUXILIARY FEEDWATER Expiration Date NA
5. (a) Applicable Construction Code B1 6.34 Code Case N-416-1 (b) Applicable Edition of Section )a Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ED Built Replacement Stamped AFW-4A FLOWSERVE AV-168 NA F015-001 2003 REPLACEMENT N CORP.
7. Description of Work REPLACE CLASS 2 AUXILIARY FEEDWATER SYSTEM 3 VALVE AFW-4A AND 2 BUTT WELDS AND ADD AN ADDITIONAL 3- BUTT WELD.
8. Tests conducted Hydrostatic E1l Pneumatic El Nominal Operating Pressure El Exempt El Other [] Pressure 971 ps ;i Test Temp. 96 deg. F
9. Remarks UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SCETION XI: CODE CASE N-416-1.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5113/2003 Name of Component AFW-4A Work Order Number 02-009751 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed 7$t4C fh Date 4 . 20 QS Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period ;t -/-C;L to 6 i' 03, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

____ Commissions NB7741, I. N, IS. A WIS 100024 Inspector' ignature National Board, State, Province, and Endorsements Date (6 - /0 20 P 3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/21/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet I of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-011096
3. Work Performed By Nuclear Manaaement Comrany. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 05B Class 3 AUXILIARY FEEDWATER Expiration Date NA
5. (a)Applicable Construction Code B1 6.34 Code Case N-416-1 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped AFW-1C FLOWSERVE AV-167 NA F016-001 2003 REPLACEMENT N CORPORATION
7. Description of Work REPLACE CLASS 3 AUXILIARY FEEDWATER SYSTEM 3 VALVE AFW-1C AND 2- 3t BUTT WELDS AND ADD AN ADDITIONAL 3' BUTT WELD.
8. Tests conducted Hydrostatic 2 Pneumatic El Nominal Operating Pressure E Exempt a Other [1 Pressure 1730 psi Test Temp. 87 deg. F
9. Remarks UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SECTION Xl: CODE CASE N-416-1.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/2112003 Name of Component: AFW-1C Work Order Number 02-011096 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed fk&If Date ,20 03 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 9 -/ - ° 2. to 4AG and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4 , ~Commissions NB7741, I, N, IS, A WIS 100024 Inspecto sSignature National Board, State, Province, and Endorsements Date & i /D 20 . I

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/5/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet I of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 02-011097
3. Work Performed By Nuclear Management Comoany. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 05B Class 3 AUXILIARY FEEDWATER Expiration Date NA
5. (a) Applicable Construction Code B16.34 Code Case N-416-1 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped AFW-1 B FLOWSERVE AV-166 NA F016-006 2003 REPLACEMENT N CORP.
7. Description of Work REPLACE CLASS 3 AUXILAIRY FEEDWATER SYSTEM 3- VALVE AFW-1B AND 4 BUTT WELDS.
8. Tests conducted Hydrostatic n Pneumatic 1 Nominal Operating Pressure E Exempt []

Other [1 Pressure 1770 psi Test Temp. 78 deg. F

9. Remarks UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SECTION XI: CODE CASE N-416-1.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/2003 Name of Component: AFW-1 B Work Order Number 02-011097 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed t OaJl44 Date l20 . 03 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period a - /-V 2- to 6 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

47 7f- Commissions N67741, I, N, IS,A WIS 100024 Inspectors ignature National Board, State, Province, and Endorsements Date & - /0 .20 03

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Comoration Date 5/13/2003 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 02-011098
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 05B Class 3 AUXILIARY FEEDWATER Expiration Date NA
5. (a) Applicable Construction Code B16.34 Code Case N-416-1 (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ED Built Replacement Stamped AFW-1A FLOWSERVE AV-165 NA F016-003 2003 REPLACEMENT N CORP.
7. Description of Work REPLACE CLASS 3 AUXILAIRY FEEDWATER SYSTEM 3" VALVE AFW-1A AND 2-3" BUTT WELDS AND ADD AN ADDITIONAL 1 -3" BUTT WELD.
8. Tests conducted Hydrostatic [ Pneumatic D Nominal Operating Pressure lX Exempt n Other [I] Pressure 1700 psi TestTemp. 76.8 deg. F
9. Remarks UTILIZATION OFASME BOILER AND PRESSURE VESSEL CODE SECTION XI: CODE CASE N-416-1.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/1 3/2003 Name of Component: AFW-1A Work Order Number: 02-011098 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed C Jffl)Or0 6twtw 71 U1 Date 6 ,20 03 Owner or Owners Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described inthe Owner's Report during the period A -/' 2- to G - 'O3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described inthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS,A WIS 100024 Inspector's Signature National Board, State, Province, and Endorsements Date C - 10 ,20 0-3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 3127/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 WorkOrder 02-011100
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 02 Class 3 SERVICE WATER Expiration Date NA
5. (a) Applicable Construction Code B1 6.34 Code Case N-416-1 (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped SW-1041 B-2 CONBRACO INDUSTRIAL NA NA SW134-218 2002 REPLACEMENT N INC.
7. Description of Work INSTALL NEW CLASS 3 AIR CONDITIONING COOLING WATER SYSTEM 2 1/2" VALVE SW-1041B-2. 2-2 1/2" FLANGES AND 2-2 1/2" BUTT WELDS.
8. Tests conducted Hydrostatic 11 Pneumatic l Nominal Operating Pressure nX Exempt E Other El Pressure 71 psi Test Temp. 44.3 deg. F
9. Remarks UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SECTION Xl: CODE CASE N-416-1.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 3127/2003 Name of Component: SW-1041B-2 Work Order Number: 02-011100 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed %I-A w0Vh Date ,20 nB Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period ol 2-027to 6i 4 3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspectors Signature National Board, State, Province, and Endorsements Date 6 ,20

./003

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/13/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 02-012745
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 36 Class 1 REACTOR COOLANT Expiration Date NA
5. (a)Applicable Construction Code ANSI B16.34 Code Case N-416-1 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped PR-iB FLOWSERVE NBR AV-266 NA RC01 8-002 2003 REPLACEMENT N CORP.
7. Description of Work REPLACE CLASS 1 REACTOR COOLANT SYSTEM 3" VALVE PR-I B AND 2-3" BUTT WELDS.
8. Tests conducted Hydrostatic n Pneumatic 1I Nominal Operating Pressure El Exempt l Other n Pressure 2240 psi Test Temp. 543 deg. F
9. Remarks UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SECTION XI: CODE CASE N-416-1.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/13/2003 Name of Component: PR-1 B Work Order Number 02-012745 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed 1W 4 la&n Date .20 03 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period ? -1/ to 6 4 -°3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspector's Signature National Board, State, Province, and Endorsements Date 6 - /a ,20 3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Coryoration Date 5/13/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet I of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-012746
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 36 Class 1 REACTOR COOLANT Expiration Date NA
5. (a) Applicable Construction Code ANSI 616.34 Code Case N-416-1 (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ED Built Replacement Stamped PR-1A FLOWSERVE NBR AV-265 NA FRO0l 8-00 1 2003 REPLACEMENT N CORP.
7. Description of Work REPLACE CLASS I REACTOR COOLANT SYSTEM 3' VALVE PR-IA AND 2- 3 BUTT WELDS.
8. Tests conducted Hydrostatic [] Pneumatic Nominal Operating Pressure p1 Exempt R Other LI Pressure 2240 psi Test Temp. 543 deg. F
9. Remarks UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SECTION XI: CODE CASE N-416-1.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/13/2003 Name of Component: PR-JA Work Order Number: 02-012746 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed /°2,(+ X4 l 0 Date .20 G3 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period c2 -1/-i2 to 6 -' -03, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspector's Signature National Board, State, Province, and Endorsements Date G - /0 20 03

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation Date 5/13/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet I of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 02-012820
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 35 Class 2 CHEMICAL AND VOLUME CONTROL Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ]ID Built Replacement Stamped CVC-261 CROSBY ASHTON GAGE NF NA C5108-001 1971 REPAIRED N CO.
7. Description of Work REMOVE FOR SET POINT TESTING CLASS 2 CHEMICAL AND VOLUNE CONTROL SYSTEM 2" VALVE CVC-216.
8. Tests conducted Hydrostatic [1 Pneumatic a Nominal Operating Pressure [ Exempt [

Other D Pressure 19 psi Test Temp. 165 deg. F

9. Remarks NOT APLLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/13/2003 Name of Component: CVC-261 Work Order Number 02-012820 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed el44)l~? chWI Ji Date 4}IL .20 03 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owners Report during the period a -/--0 to 03, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspector's Signature National Board, State, Province, and Endorsements Date 6 -/l ,20 03

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/13/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-012821
3. Work Performed By Nuclear Management Companv. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 35 Class 2 CHEMICAL AND VOLUME CONTROL Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped CVC-40 CROSBY VALVE & GAGE 51036 M2 NA CS015-001 1971 REPAIRED N CO.
7. Description of Work REMOVE FOR SETPOINT TESTING CLASS 2 CHEMICAL AND VOLUME SYSTEM 3' VALVE CVC-40.
8. Tests conducted Hydrostatic LI Pneumatic LI Nominal Operating Pressure p3 Exempt LI Other [ Pressure 22 psi Test Temp. 86 deg. F
9. Remarks NOT APPLICABLE Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/13/2003 Name of Component: CVC-40 Work Order Number: 02-012821 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed 6 C'! & WZW4VA1, 040Mv1 Date fir .20 Q3 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owners Report during the period a-/- °'? to l e A and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described inthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

go,__ G o Commissions N87741, I, N, IS, A WIS 100024 v Inspectors Signature National Board, State, Province, and Endorsements Date 6C /O ,20 0 -

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation Date 5/9/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-012885
3. Work Performed By Nuclear Manaaement Companv. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 06 Class 2 MAIN STEAM AND STEAM DUMP Expiration Date NA
5. (a)Applicable Construction Code ASME III CL. C-1966 Code Case NA (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped SG-1A WESTINGHOUSE 1141 68-28 00035 1968 REPAIRED Y (CLASS 2)
7. Description of Work OPEN FOR INSPECTION CLASS 2 MAIN AUXILIARY STEAM AND STEAM DUMP SYSTEM STEAM GENERATOR 1A SECONDARY SIDE MANWAYS INCLUDING REPLACING 4 BOLTS.
8. Tests conducted Hydrostatic [1 Pneumatic 1 Nominal Operating Pressure [aJ Exempt [

Other [ Pressure 1021 psi ii Test Temp. 547 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/9/2003 Name of Component: SG-1A (CLASS 2)

Work Order Number: 02-012885 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed /3g - I L £ Date ,20 a Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described inthe Owner's Report during the period 2-/-0-2 to - -i -C3 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

'la" C oCommissions NB7741, I, N, IS, A WIS 100024 Inspectors Signature National Board, State, Province, and Endorsements Date bt- t 20 V3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/9/2003 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-012891
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 06 Class 2 MAIN STEAM AND STEAM DUMP Expiration Date NA
5. (a)Applicable Construction Code ASME III CL. C-1966 Code Case NA (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped SG-1A (CLASS WESTINGHOUSE 1141 68-28 00035 1968 REPAIRED Y 2)
7. Description of Work OPEN FOR INSPECTION CLASS 2 MAIN AUXILIARY STEAM AND STEAM DUMP SYSTEM STEAM GENERATOR IA SECONDARY SIDE HAND HOLES.
8. Tests conducted Hydrostatic [] Pneumatic L Nominal Operating Pressure p3 Exempt []

Other [n Pressure 1021 psi Test Temp. 547 deg.F

9. Remarks NOT APPLICABLE.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/9/2003 Name of Component: SG-1A (CLASS 2)

Work Order Number 02-012891 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed b 40 e HIO ODate 4 .20 02 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period R -/-, X to 6 X 1°3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspectors Signature National Board, State, Province, and Endorsements Date G - ,20 '3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/9/2003 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. I N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-012892
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 06 Class 2 MAIN STEAM AND STEAM DUMP Expiration Date NA
5. (a)Applicable Construction Code ASME III CL.C-1 966 Code Case NA (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped SG-1 B (CLASS WESTINGHOUSE 1142 68-29 00036 1968 REPLACEMENT Y 2)
7. Description of Work OPEN FOR INSPECTION CLASS 2 MAIN AUXILIARY STEAM AND STEAM DUMP SYSTEM STEAM GENERATOR 1B SECONDARY SIDE MANWAYS ICLUDING REPLACING 2 BOLTS.
8. Tests conducted Hydrostatic F1 Pneumatic n Nominal Operating Pressure El Exempt n Other DI] Pressure 1006 psii Test Temp. 545 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/9/2003 Name of Component: SG-1B (CLASS 2)

Work Order Number 02-012892 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed /% & ef I rW&4Wq Date A LL t ,20 03 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period og-/O?7 to 6 -6 O 3 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

'04, 7A~tll~ Commissions N87741, i, N.IS,A WIS 100024 C, Inspector's Signature National Board, State, Province, and Endorsements Date ____ /__ _ D0

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/9/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-012898
3. Work Performed By Nuclear Management Company, LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 06 Class 2 MAIN STEAM AND STEAM DUMP Expiration Date NA
5. (a) Applicable Construction Code ASME III CL.C-1966 Code Case NA (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped SG-1B (CLASS WESTINGHOUSE 1142 68-29 00036 1968 REPAIRED Y 2)
7. Description of Work OPEN FOR INSPECTION CLASS 2 MAIN AUXILIARY STEAM AND STEAM DUMP SYSTEM STEAM GENERATOR 1B SECONDARY SIDE HAND HOLES.
8. Tests conducted Hydrostatic EJ Pneumatic [] Nominal Operating Pressure M Exempt LI Other [1 Pressure 1006 psi Test Temp. 545 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/912003 Name of Component: SG-1B {CLASS 2)

Work Order Number: 02-012898 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed 4&w°&&.I cL Pk 4 }Date n 9 .20 03 Owner or Owners Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 0 4/-0 A- to C , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Z . g o Commissions NB7741, I, N, IS, A WIS 100024 a Inspectors Signature W6 National Board, State, Province, and Endorsements Date _ _-/_ __ 20 0_3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 4/17/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 02-012937
3. Work Performed By Nuclear Management Comnany. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 23 Class 2 CONTAINMENT SPRAY Expiration Date NA
5. (a) Applicable Construction Code B16.5-1967 Code Case NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped ICS-8A ANCHOR/DARLING VALVE EB992-1-1 NA ICS004-005 1970 REPAIRED N COMPANY
7. Description of Work OPEN FOR REPAIR CLASS 2 CONTAINMENT SPRAY SYSTEM 6" VALVE ICS-8A.
8. Tests conducted Hydrostatic a Pneumatic E1l Nominal Operating Pressure E3 Exempt 2 Other [1 Pressure 275 psi Test Temp. 71.5 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 4117/2003 Name of Component: ICS-8A Work Order Number 02-012937 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed PA A41$IU M AtLl Date .,20 0 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7 -°2- to A '4 Ra, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

/96us Commissions NB7741, I, N, IS, A WIS 100024 spector's Signature National Board, State, Province, and Endorsements Date 4 f20

- /° ° 3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/5/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03000176
3. Work Performed By Nuclear Manaaement Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 02 Class SERVICE WATER Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case N-416-1 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped SW-1 038B NUCLEAR MANAGEMENT NA NA NA 2003 REPLACEMENT N PIPING COMPANY
7. Description of Work REINSTALLATION OF CLASS 3 SERVICE WATER SYSTEM 4" PIPING AND 4 WELDS FOR SERVICE WATER SYSTEM TRAINN B NEAR VALVE SW-1038B.
8. Tests conducted Hydrostatic n Pneumatic ] Nominal Operating Pressure [ Exempt ]

Other [ Pressure 104 psiii Test Temp. 50 deg. F

9. Remarks UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SECTION XI: CODE CASE N-416-1.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/5/2003 Name of Component: SW-1038B PIPING Work Order Number 03-000176 Certificate of Compliance We Certify that the statements made In the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed ° Date Zip 20 O3 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period -' 'O - 2. to C4 -' °3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

X4 7749-b. Commissions NB7741, I, N,IS,A WIS 100024 Inspector's sgnature National Board, State, Province, and Endorsements Date 6_-/_ 20 °3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section )a

1. Owner Wisconsin Public Service Corporation Date 4'29/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet I of a
2. Plant Kewaunee Nuclear Power Plant Unit No. I N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-000177
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 02 Class 3 SERVICE WATER Expiration Date NA
5. (a) Applicable Construction Code 131.1-1967 Code Case N-416-1 (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Nameof Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ED Built Replacement Stamped SW-1043A NUCLEAR MANAGEMENT NA NA NA 2003 REPLACEMENT N PIPING COMPANY
7. Description of Work REINSTALLATION OF CLASS 3 SERVICE WATER SYSTEM 3 PIPING AND 3 WELDS FOR SERVICE WTER SYSTEM TRAIN A NEAR VALVE SW-1043A.
8. Tests conducted Hydrostatic n Pneumatic n Nominal Operating Pressure "Z Exempt ]

Other j Pressure 102 psi Test Temp. 50 deg. F

9. Remarks UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SECTION XI: CODE CASE N-416-1.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 4/29/2003 Name of Component: SW-1043A PIPING Work Order Number 03-00I077 Certificate of Compliance We Certify that the statements made In the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed 7 °/ C LM J riA /0 nf Date L,20 or Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period .; -/02 to ' -4' °3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspector's Signature National Board, State, Province, and Endorsements Date 6- / ,20 v3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 4/29/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-000177
3. Work Performed By Nuclear Management Companv. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 02 Class 3_ SERVICE WATER Expiration Date NA
5. (a)Applicable Construction Code B31.1-1967 Code Case N-416-1 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped SW-1038A NUCLEAR MANAGEMENT NA NA NA 2003 REPLACEMENT N PIPING COMPANY
7. Description of Work REINSTALLATION OF CLASS 3 SERVICE WATER SYSTEM 4" PIPING AND 4" WELD FOR SERVICE WATER SYSTEM TRAIN A NEAR VALVE SW-1038A.
8. Tests conducted Hydrostatic [ Pneumatic LI Nominal Operating Pressure pa Exempt []

Other [1 Pressure 102 psi Test Temp. 50 deg. F

9. Remarks UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SECTION XI: CODE CASE N-416-1.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 412912003 Name of Component: SW-1038A PIPING Work Order Number 03-000177 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed / ° C 1(We tJO > 4 0 A c e Date ,20 0-3 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 1 /CV Z to 6 -G -°3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspector' ignature National Board, State, Province, and Endorsements Date 4- (0 ,20 °3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/5/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-000420
3. Work Performed By Nuclear Manaaement Comrany. ILC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. identification of System 31 Class 3 COMPONENT COOLING Expiration Date NA
5. (a) Applicable Construction Code ASME VIII-DIV.1 Code Case N-416-1 (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped AHCC1-1A ENGINEERS AND S-26125 3269 00113 2003 REPLACEMENT Y FABRICATORS
7. Description of Work REPLACE CLASS 3 COMPONENT COOLING WATER HEAT EXCHANGER 1A INCLUDING 12" SERVICE WATER SYSTEM PIPING AND 12" SERVICE WATER SYSTEM WELDS AND 16" COMPONENT COOLING WATER SYSTEM PIPING AND 16" COMPONENT COOLING WATER SYSTEM WELDS.
8. Tests conducted Hydrostatic J:J Pneumatic 1a1 Nominal Operating Pressure []3 Exempt Other [ Pressure 140 psi Test Temp. 73 deg. F
9. Remarks SERVICE WATER SIDE PRESSURE:104 PSI. TEST TEMP: 40 DEG. F: COMPONENT COOLING WATER SIDE TEST PRESSURE: 140 PSI: TEST TEMP: 73 DEG. F: UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SECTION XI: CODE CASE N-416-1.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 55/52003 Name of Component: AHCC1-1A Work Order Number 03-000420 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed P14 Date 6 .L20 013 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owners Report during the period 2 -/-CA to 6; ' -03, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspector's Signature National Board, State, Province, and Endorsements Date 4 -/0 .20 3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Cororation Date 511/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-000421
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 31 Class 3 COMPONENT COOLING Expiration Date NA
5. (a) Applicable Construction Code ASME VIII-DIV.1 Code Case N-416-1 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped AHCC2-1B ENGINEERS AND S-26126 3270 00114 2003 REPLACEMENT Y FABRICATORS
7. Description of Work REPLACE CLASS 3 COMPONENT COOLING WATER SYSTEM HEAT EXCHANGER I B INCLUDING 12" SERVICE WATER PIPING AND 12" SERVICE WATER PIPING WELDS AND 16 COMPONENT COOLING WATER PIPING AND 16" COMPONENT COOLING WATER PIPING WELDS.
8. Tests conducted Hydrostatic 2 Pneumatic go Nominal Operating Pressure pa Exempt LI Other [1j Pressure 135 psi Test Temp. 92 deg. F
9. Remarks SERVICE WATER SIDE TEST PRESSURE: 95 PSI: TEST TEMP: 45.4 DEG. F: COMPONENT COOLING WATER SIDE TEST PRESSURE: 135 PSI: TEST TEMP: 92 DEG. F: UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SECTION XI: CODE CASE N-416-1.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/1/2003 Name of Component: AHCC2-1 B Work Order Number: 03-000421 Certificate of Compliance We Certify that the statements made In the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed 7 G p t I Io Date . 03

,20 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period a -/-a ; to G and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report In accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's ReporL Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4 , G o Commissions NB7741, I, N, IS, A WIS 100024 Inspector's Sig ture National Board, State, Province, and Endorsements Date b6 /°o ,20 ^

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corooration Date 5/5/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet I of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-004032
3. Work Performed By Nuclear Management Comoanv. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 34 Class 1 RESIDUAL HEAT REMOVAL Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ED Built Replacement Stamped RHR-1A VELAN VALVE NF NA AC104.001 1972 REPAIRED N CORPORATION
7. Description of Work REPAIR BODY TO BONNET LEAKAGE ON CLASS 1 RESIDUAL HEAT REMOVAL SYSTEM 8" VALVE RHR-1A BY REMOVING 1 STUD FOR CLEANING AND INSPECTING AND 15 STUDS FOR CLEANING AND INSPECTING.
8. Tests conducted Hydrostatic [ Pneumatic [ Nominal Operating Pressure [] Exempt El Other jn Pressure psi Test Temp. deg. F
9. Remarks NOT APPLICABLE Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/5/2003 Name of Component: RHR-1A Work Order Number: 03-004032 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed C X Date 8 ,20 03 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owners Report during the period a -/ 4 2 to 6 a/ i23, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

A54 _ G oCommissions NB7741, I, N, IS, A WIS 100024 Inspectors gnature National Board, State, Province, and Endorsements Date 6- /o ,20 03

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5(5/2003 700 North Adams P.O.Box 19001 Green Bav. WI 54307-9001 Sheet I of a
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee, WI 54216-9511 Work Order ,03004034
3. Work Performed By Nuclear Management Comoany, LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 35 Class 2 CHEMICAL AND VOLUME CONTROL Expiration Date NA
5. (a)Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped CVC-H96 ITT GRINNEL NA NA CVC-H96 1967 REPAIRED N COMPANY
7. Description of Work REPAIR CLASS 2 CHEMICAL AND VOLUME CONTROL SYSTEM HYDRAULIC SNUBBER CVC-H96 DUE TO MISSING ZIRC FITTING.
8. Tests conducted Hydrostatic [ Pneumatic [ Nominal Operating Pressure L Exempt [El Other [] Pressure psi Test Temp. deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/5/2003 Name of Component: CVC-H96 Work Order Number 03-004034 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed  ? °wkv474i nw ravAt&2&&WV Date ,20 03 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period c J ° to 4 3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4 S L Commissions NB7741, I, N, IS,A WIS 100024 I~nspector's Signature National Board, State, Province, and Endorsements Date C1/O ,20 0 3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/5/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Kewaunee Nuclear Power Plant Unit No. 1
2. Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-004034
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 33 Class 2 SAFETY INJECTION Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped RSI-H2 ITT GRINNELL VALVE NF NA NA 1974 REPAIRED N CO.
7. Description of Work REPAIR CLASS 2 SAFETY INJECTION SYSTEM HYDRAULIC SNUBBER RSI-H2 DUE TO MISSING ZIRC FITTING.
8. Tests conducted Hydrostatic [ Pneumatic L Nominal Operating Pressure LI Exempt []

Other LI Pressure psi Test Temp. deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 51/2003 Name of Component: RSI-H2 Work Order Number 03-004034 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed ft4 Lz 4 b AoyQs. 1t 4WMA., Date 420 20 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owners Report during the period a -I-0 ; to 6 - - , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspector's Sig ature National Board, State, Province, and Endorsements Date C- /O - ° 5 ,20 ° 3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation Date 515/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet I of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. I N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-004034
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 33 Class 2 SAFETY INJECTION Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ED Built Replacement Stamped RSI-H2A ITT GRINNELL VALVE NA NA NA 1967 REPAIRED N CO.
7. Description of Work REPAIR CLASS 2 SAFETY INJECTION SYSTEM 3" HYDRAULIC SNUBBER RSI-H2A DUE TO INADEQUATE MOVEMENT.
8. Tests conducted Hydrostatic [] Pneumatic [ Nominal Operating Pressure r] Exempt m Other [] Pressure psi Test Temp. deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/5/2003 Name of Component: RSI-H2A Work Order Number: 03-004034 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed D ate4 tL 4 20 03 Owner or Owners Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period c -/-0 2- to 6 O4 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

nsp G i ureg Commissions NB7741, I, N, IS, A WIS 100024 Inspectors Senature National Board, State, Province, and Endorsements Date

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corooration Date 5/512003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03Q004034
3. Work Performed By Nuclear Management Comoany. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NsIA
4. Identification of System 35 Oass 2 CHEMICAL AND VOLUME CONTROL Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Bulilt Replacement Stamped l

RCVC-H1-91 ITT GRINNEL NA NA NA 1967 REPAIRED N COMPANY

7. Description of Work REPAIR CLASS 2 CHEMICAL AND VOLUME CONTROL SYSTEM 2" HYDRAULIC SNUBBER RCVC-H191 BY REPLACING PIN.
8. Tests conducted Hydrostatic [j Pneumatic [a] Nominal Operating Pressure E2 Exempt [23 Other [] Pressure psi Test Temp. deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/5/2003 Name of Component: RCVC-H191 Work Order Number 03-004034 Certificate of Compliance We Certify that the statements made In the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed Y,0&4e4.La l2 et 4 Jyih m 0 Date ,20 Ofi Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described In the Owner's Report during the period P- /- to 6 6t-3, . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4 1 g oCommissions NB7741, I, N, IS,A WIS 100024 Inspectors Signature National Board, State, Province, and Endorsements Date __ _ /_ _ _3 ,_20

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/512003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet I of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-004034
3. Work Performed By Nuclear Management Company, LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 35 Class 1 CHEMICAL AND VOLUME CONTROL Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b)Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ED Bulilt Replacement Stamped RCVC-H33A ITT GRINNELL VALVE NA NA NA 1967 REPAIRED N CO.
7. Description of Work REPAIR CLASS 1 CHEMICAL AND VOLUME CONTROL SYSTEM HYDRAULIC SNUBBER RCVC-H33A DUE TO PIPE CLAMP BINDING.
8. Tests conducted Hydrostatic j1 Pneumatic [j Nominal Operating Pressure L Exempt E Other [] Pressure psi Test Temp. deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/5/2003 Name of Component: RCVC-H33A Work Order Number 03-004034 Certificate of Compliance We Certify that the statements made In the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed full Date 1 ,20 05 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 9 - /1-O to 6~ t0 G-land state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

14 g oCommissions NB7741, I, N,IS,A WIS 100024 Inspectors Signature National Board, State, Province, and Endorsements Date _ i______ _ ,20 0.3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/5/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-004034
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 35 Class 1 CHEMICAL AND VOLUME CONTROL Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped RCVC-H33B ITT GRINNELL VALVE NA NA NA 1967 REPAIRED N CO.
7. Description of Work REPLACE CLASS 1 CHEMICAL AND VOLUME CONTROL SYSTEM 2" HYDRAULIC SNUBBER RCVC-H33B BY REPLACING COTTER PIN.
8. Tests conducted Hydrostatic E_ Pneumatic El Nominal Operating Pressure E1 Exempt 3 Other [E Pressure psi Test Temp. deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/5/2003 Name of Component: RCVC-H33B Work Order Number 03-004034 Certificate of Compliance We Certify that the statements made In the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed £~/ C J4 ct1 Th N G I Date .,20 0L Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period QI -/'O 2- to C '4 s°3 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

lo:r, G ---~

o24 Commissions NB7741, I, N, IS, A WIS 100024 qnspector's Signa ure National Board, State, Province, and Endorsements Date _6-___ 20_3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/512003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet I of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-004034
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 35 Class 2 CHEMICAL AND VOLUME CONTROL Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped RCVC-H186 ITT GRINNEL NA NA NA 1967 REPAIRED N COMPANY
7. Description of Work REPAIR CLASS 2 CHEMICAL AND VOLUME CONTROL SYSTEM 2- HYDRAULIC SNUBBER RCVC-H186 DUE TO PIPE CLAMP BINDING.
8. Tests conducted Hydrostatic [I] Pneumatic El Nominal Operating Pressure D Exempt [E Other [1 Pressure psi Test Temp. deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/5/2003 Name of Component: RCVC-H186 Work Order Number 03-004034 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed )Y o0. l rwn°w Date 20 Q0

.0A1 Owner or Owners Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period A /-°; to 4- 03 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described inthis Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspectors Signg~(ure National Board, State, Province, and Endorsements Date 6-/c .20 o__

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/512003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of ?

Unit No. I

2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03004051
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorizaton No. NA
4. Identification of System 34 Class 1 RESIDUAL HEAT REMOVAL Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped RHR-2B VELAN VALVE NF NA AC104-004 1972 REPAIRED N CORPORATION
7. Description of Work REPAIR BODY TO BONNET LEAK ON CLASS 1 RESIDUAL HEAT REMOVAL SYSTEM 8" VALVE RHR-2B BY REMOVING 1 STUD FOR CLEANING AND INSPECTING AND 15 STUDS FOR CLEANING AND INSPECTING.
8. Tests conducted Hydrostatic a Pneumatic g Nominal Operating Pressure nI Exempt nl Other n Pressure psi Test Temp. deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/5/2003 Name of Component RHR-2B Work Order Number 0S 004051 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed / L o'taAv fAwC Date i .20 03 It Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boder Inspection and Ins. Co. of Hartford. CT have inspected the components described in the Owners Report during the period A? /-0 2 to 4 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty. expressed or implied, conceeming the examinations and corrective measures described in this Owners Report Futhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

/0-51 - Commissions NB7741. I, N. IS, A WIS 100024 XJ Inspector's Signature National Board, State, Province, and Endorsements Date 6£ / _- ,20 O 5

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section )a

1. Owner Wisconsin Public Service Corporation Date 56912003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet .1 of £
2. Plant Kewaunee Nuclear Power Plant Unit No. I N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-004053
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 35 Class 1 CHEMICAL AND VOLUME CONTROL Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped CVC-15 MASONEILAN H40686-1 -1 NA CS1 11-002 1969 REPLACEMENT N INTERNATIONAL
7. Descripbon of Work REPAIR BODY TO BONNET LEAK ON CLASS 1 CHEMICAL AND VOLUME CONTROL SYSTEM 2" VALVE CVC-15.

REPLACE 8 VALVE BONNET STUDS.

8. Tests conducted Hydrostatic 1] Pneumatic [] Nominal Operating Pressure jM] Exempt n Other n Pressure 2240 psi Test Temp. 5 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/9/2003 Name of Component: CVC-15 Work Order Number: 03-004053 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed }Ofla e &A g t& Date ,20 03 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT 2

have inspected the components described in the Owners Report during the period 6L/-) -to 6' 4 10a and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspectors Signature National Board, State, Province, and Endorsements Date ___ / _ _ ,20 03

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 4/22/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-004115
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 36 Class 1 REACTOR COOLANT Expiration Date NA
5. (a)Applicable Construction Code 831.1-1967 Code Case NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ED Built Replacement Stamped RTD- TEXAS PIPE NA NA NA 1967 REPAIRED N W70S BENDING
7. Description of Work REPAIR BY LIGHT FILING CLASS I REACTOR COOLANT SYSTEM 2" SOCKET WELD RTD-W70S DUE TO LINEAR INDICATION.
8. Tests conducted Hydrostatic [ Pneumatic 2 Nominal Operating Pressure [] Exempt p7 Other [] Pressure psi Test Temp. deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 412212003 Name of Component: RTD-W70S Work Order Number: 03-004115 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed /Ct'. Date L .20 of3 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period d to 6 -03,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

'7_4-4-g Commissions NB7741, I, N. IS, A WIS 100024 Inspectors Sigkture National Board, State, Province, and Endorsements Date 6-/ ,20 03 L

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation Date 4/29/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-004134
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 36 Class I REACTOR COOLANT Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped RTD-H7 ITT GRINNELL VALVE NF NA NA 1967 REPAIRED N CO.
7. Description of Work REPAIR CLASS 1 REACTOR COOLANT SYSTM 2" SUPPORT RTD-H7 DUE TO IMPROPER SUPPORT SPRING SETTING.
8. Tests conducted Hydrostatic [1 Pneumatic n Nominal Operating Pressure [1 Exempt m Other [] Pressure psi Test Temp. deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 4/29/2003 Name of Component: RTD-H7 Work Order Number: 03-004134 Certificate of Compliance We Certify that the statements made In the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed )7v4 eJ / ATP UO 1 Date 6L.p,20 03 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period oc-/-i72 to v64 -03, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspector's S nature National Board, State, Province, and Endorsements Date 6 -/0 ,20 0-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Comoration Date 4/29/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-004135
3. Work Performed By Nuclear Management Comoany. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. identification of System 36 Class 1 REACTOR COOLANT Expiration Date NA
5. (a)Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped RTD-H12 ITT GRINNELL VALVE NF NA NA 1967 REPAIRED N CO.
7. Description of Work REPAIR CLASS 1 REACTOR COOLANT SYSTEM 2" SUPPORT RTD-H12 DUE TO IMPROPER SPRING SETTING.
8. Tests conducted Hydrostatic [] Pneumatic [ Nominal Operating Pressure [] Exempt n3 Other n Pressure psi Test Temp. deg. F
9. Remarks NOT APPLiCABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 4/2912003 Name of Component: RTD-H12 Work Order Number 03-004135 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed i7b .wz4z° &G Date 4 .20 03 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period el-/- to 4-4 -03, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4 , 2'- Commissions NB7741, I, N, IS, A WIS 100024 National Board, State, Province, and Endorsements 1 Inspector's Signature Date 6 -/_ _3 2__0

-11

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 4/30/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307.9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-004136
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 36 Class 1 REACTOR COOLANT Expiration Date NA
5. (a)Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ED Built Replacement Stamped RC-H23 ITT GRINNELL VALVE NF NA NA 1967 REPAIRED N COMPANY
7. Description of Work REPAIR CLASS 1 REACTOR COOLANT SYSTEM 3' SUPPORT RC-H23 DUE TO LOOSE BOLT.
8. Tests conducted Hydrostatic g Pneumatic El Nominal Operating Pressure U1 Exempt p1 Other 2 Pressure psi Test Temp. deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 4/30/2003 Name of Component: RC-H23 Work Order Number: 03-004136 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed W . Ag We4nu w'1 Date 4 .20 03 Owner or Owners Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period & -/ O.2 to C-C-03, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

X2?~#~4..- >Commissions NB7741. I, N, IS, A WIS 100024 Inspector's Signature National Board, State, Province, and Endorsements Date 6-/0 ,20 £a_

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corooration Date 4/29/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-004138
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 05A Class 2 FEEDWATER Expiration Date NA S. (a) Applicable Construction Code NA Code Case NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ED Built Replacement Stamped SG-AH- MCDOWELL 25.12620.004-7 NA 1S-0066 1971 REPAIRED N 2 WELLMAN
7. Description of Work REPAIR CLASS 2 FEEDWATER SYSTEM STEAM GENERATOR lB 900 KIP LARGE BORE HYDRAULIC SNUBBER ENCLOSURE ROD ON THE FLUID RESERVOIR.
8. Tests conducted Hydrostatic [j Pneumatic El Nominal Operating Pressure Eli Exempt [EI Other [1 Pressure psi Test Temp. deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 4129/2003 Name of Component: SG-AH-2 Work Order Number 03-004138 Certificate of Compliance We Certify that the statements made inthe report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed io4wgw. g oVd J Date 44 .20 0n Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have Inspected the components described inthe Owner's Report during the period e*7/-V 2- to k -602and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described inthis Owner's Report inaccordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable inany manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4~.. gCommissions NB7741, I, N,IS,A WIS 100024 Inspector's Sigature National Board, State, Province, and Endorsements Date __ _ /_ _20_3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation Date 5/13/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-004162
3. Work Performed By Nuclear Management Comoany. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 34 Class 2 RESIDUAL HEAT REMOVAL Expiration Date NA
5. (a) Applicable Construction Code SECTION ill CLASS 2 Code Case NA (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped RHR-33-1 CROSBY VALVE AND N62651 0001 NA AC1 15-001 1978 REPAIRED N GAGE
7. Description of Work REMOVE FOR SET POINT TESTING CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM 4 VALVE RHR-33-1.
8. Tests conducted Hydrostatic B Pneumatic a Nominal Operating Pressure px Exempt []

Other [ Pressure 320 ps ii Test Temp. 117 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/1 3/2003 Name of Component: RHR-33-1 Work Order Number: 03-004162 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed d 60y VItV Date 6tL .20 0 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 0-1-D 2 to ,4-0-#3 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

- Go ~ Commissions NB7741, I, N. IS, A WIS 100024 Inspector's ignature National Board, State, Province, and Endorsements Date _ - to_ _ 20 03

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corooration Date 5113/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet .1 of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-004163
3. Work Performed By Nuclear Management ComDany. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 35 Class 2 CHEMICAL AND VOLUME CONTROL Expiration Date NA
5. (a)Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped LD-5 CROSBY ASHTON GAGE NF NA CS109-001 1970 REPAIRED N CO.
7. Description of Work REMOVE FOR SET POINT TESTING CLASS 2 CHEMICAL AND VOLUME CONTROL SYSTEM 2" VALVE LD-5.
8. Tests conducted Hydrostatic a Pneumatic n Nominal Operating Pressure pV Exempt n]

Other E1 Pressure 260 psi Test Temp. 306 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/1312003 Name of Component: LD-5 Work Order Number 03-004163 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed W)4 OA*7DM' Date 6 4 .20 a Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford,&CT have inspected the components described in the Owners Report during the period 0 /-O- to 4 - and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspector's Senature National Board, State, Province, and Endorsements Date _ __ _ - 20 O___

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/1/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-004172
3. Work Performed By Nuclear Management Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 31 Class 3 COMPONENT COOLING Expiration Date NA
5. (a)Applicable Construction Code ASME Vill-DIV.1 Code Case NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ED Built Replacement Stamped AHCC1-1A-S3 ENGINEERS AND S-26125 3269 00113 2003 REPLACEMENT Y FABRICATION
7. Description of Work INSTALL BEVELED PLATE WASHER ON CLASS 3 COMPONENT COOLING WATER SYSTEM COMPONENT COOLING WATER HEAT EXCHANGER 1A AHCCI-1A-S3 BASE SUPPORT.
8. Tests conducted Hydrostatic 1ii Pneumatic LI Nominal Operating Pressure E] Exempt pR Other [1 Pressure psi Test Temp. deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 511/2003 Name of Component: AHCC1-1A-S3 Work Order Number 03-004172 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed /°ANL6 &I"2VL Date 1 A ,20 03 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 99 -, *1 7 to 6 _'3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

o4 G7 Commissions NB7741, I,N, IS, A WIS 100024 Inspector's Si ture National Board, State, Province, and Endorsements Date 6-/° ,20 ° 3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date ,5/5/200 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of i
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-004211
3. Work Performed By Nuclear Manaaement Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 36 Class 1 REACTOR COOLANT Expiration Date NA
5. (a)Applicable Construction Code B31.1-1967 Code Case NA (b)Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped FE-459 VICKERY SIMMS NF NA 27040 1970 REPAIRED N INC.
7. Description of Work REPAIR CLASS 1 REACTOR COOLANT SYSTEM 3" FLANGE FE-459 DUE TO EVIDENCE OF LEAKAGE,
8. Tests conducted Hydrostatic aj1 Pneumatic U Nominal Operating Pressure [] Exempt lX Other [In Pressure psi Test Temp. deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/512003 Name of Component: FE-459 Work Order Number: 03-004211 Certificate of Compliance We Certify that the statements made In the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed t'MVC IA Date 2 Ob20 Owner or Owners Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owners Report during the period .. Lz/- 0 to 6 -% -03andstate that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspectors Signat National Board, State, Province, and Endorsements Date 6 - /p ,20,3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/2003 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet 1 of i:
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 03-005273
3. Work Performed By Nuclear Manaaement Company. LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 23 Class 2 CONTAINMENT SPRAY Expiration Date NA
5. (a) Applicable Construction Code 531.1-1967 Code Case NA (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID BuIlt Replacement Stamped ICS-H8 ITT GRINNELL VALVE NA NA NA 1971 REPAIRED N CO.
7. Description of Work REPAIR CLASS 2 INTERNAL CONTAINMENT SPRAY SYSTEM HYDRAULIC SNUBBER ICS-H8.
8. Tests conducted Hydrostatic [ Pneumatic [] Nominal Operating Pressure [1 Exempt @

Other [], Pressure psi Test Temp. deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufactureres Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/512003 Name of Component: ICS-H8 Work Order Number. 03-005273 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed e 9 Date b n ,20 05 Owner or Owners Designee, Tile Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period &A to { t3, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Signature G/lnspector's National Board, State, Province, and Endorsements Date 6-/o 204a3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xi

1. Owner Wisconsin Public Service Corporation Date 5/12M32 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Sheet t of Z
2. Plant Kewaunee Nuclear Power Plant Unit No. I N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 03405353
3. Work Performed By Nuclear Management Cornmanv. LLC Type Code Sym. Stamp NA 700 First Street. Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 3 Class L SAFETY INJECTION Expiration Date NA
5. (a) Applicable Construction Code S16.5.1967 Code Case NA (b)Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ED Built Replacement Stamped RHR-299A ALOYCO NF NA S1008-001 1970 REPAIRED N INC.
7. Description of Work REPAIR CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM 6 VALVE RHR-299A DUE TO SEAT LEAKAGE.
8. Tests conducted Hydrostatic [ Pneumatic a:j Nominal Operating Pressure [ Exempt n Other J1 Pressure 28 ps ii Test Temp. 75 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 5/1 2/2003 Name of Component: RHR-299A Work Order Number: 03-005353 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed b0MC-McrA~t1A- Date v 20 a0 Owner or Owners Designee, Title Certificate of INSER VICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owners Report during the period 0 1/0 Z to 6("S1 Oand state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

____ Commissions NB7741, I, N, IS, A WIS 100024 Inspectors Sigature National Board, State, Province, and Endorsements Date 6 - /D ,20A3

ATTACHMENT 6 NUCLEAR MANAGEMENT COMPANY, LLC KEWAUNEE NUCLEAR PLANT DOCKET 50-305 August 6, 2003 Letter from Thomas Coutu (NMC)

To Document Control Desk (NRC)

Examination Summary for Scheduled and Augmented Inservice Inspection (ISI) Program

NUCLEAR MANAGEMENT COMPANT, LLC KEWAUNEE NUCLEAR POWER PLANT 3RD INTERVAL: 3RD PERIOD: 2ND OUTAGE 2003 EXAMINATION

SUMMARY

INTRODUCTION An Inservice Inspection (QSI)Program (Scheduled and Augmented) was performed at the Kewaunee Nuclear Power Plant from May 8, 2002 through December 5, 2002 (Non Refueling Outage) and April 5, 2003 through May 11, 2003 (Closing of GI following Refueling Outage) by Kewaunee Nuclear Power Plant and Lambert, MacGill, and Thomas, Inc.(LMT) examination personnel.

Examinations were performed to satisfy the requirements of:

  • ASME Boiler and Pressure Vessel Code Section XI 1989 Edition
  • ASME Boiler and Pressure Vessel Code Section XI 1995 Edition 1996 Addenda Appendix VIII Performance Demonstration for Ultrasonic Examination Systems as required by Code of Federal Regulations IOCFR50.55a(g)(6)(ii)(c) and Nuclear Regulatory Commission 10CFR Part 50 Federal Register/Vol.64, Number 183/September 22, 1999/Rules and Regulations
  • Kewaunee Nuclear Power Plant OE Reports OE-15071 and OE 15222 The Inservice Inspection Program Plan and Augmented Inservice Inspection Program Plan located under Tab C was prepared by Nuclear Management Company, LLC - Kewaunee Nuclear Power Plant for the 3rd Interval: 3rd Period: 2nd Outage as identified in the Kewaunee Nuclear Power Plant Third 10-Year Inservice Inspection (ISI) Program 1994-2004.

Examinations during this Refueling Outage were performed to continue the 3rd Interval: 3rd Period Examination Requirements of ASME Boiler and Pressure Vessel Code Section XI 1989 Edition and Kewaunee Nuclear Power Plant Third 10-Year Inservice Inspection (ISI) Program 1994-2004.

Page 1 of 4

The following items were examined:

  • Reactor Vessel Control Rod Drive Mechanisms and 3/4" Head Vent Line
  • Regenerative Heat Exchanger Tubesheet to Shell Weld
  • Class 1 and Class 2 Piping Welds
  • Class 1, Class 2 and Class 3 Piping and Component Supports and Hangers
  • Class 1 and Class 2 Reactor Vessel Conoseal Bolting, Steam Generator Primary Side Manway Bolting, Pressurizer Manway Bolting, Flange Bolting and Valve Bonnet Bolting
  • Preservice Examination of Class 1 Piping Welds
  • Preservice Examination of Class 1 Valve Bonnet Bolting
  • Preservice Examination of Component Cooling Water Heat Exchangers 1A and 1B Supports
  • Class 1 System Leakage Test
  • Class 2 and Class 3 System Inservice and Functional System Pressure Tests EXAMINATIONS The examinations performed were in accordance with an approved Inservice Inspection Program Plan located under Tab C of the final report. Examination Procedures were approved prior to the start of examinations and certification documents relative to personnel, equipment and materials were reviewed and determined to be satisfactory.

Some of the arrangements and details of the Kewaunee Nuclear Power Plant Components and Piping Systems were designed and fabricated before ASME Boiler and Pressure Vessel Code Section XI Code requirements were established. Examinations performed were intended to examine 100% of the required surface or volume. In some cases, examinations were limited by geometric, metallurgical or design/access restrictions. In each case, the occurrence and cause of the limitation was documented. In all cases the maximum amount achievable was examined.

Page 2 of 4

Witnessing and surveillance of the examinations were conducted by: United States Nuclear Regulatory Commission and Hartford Steam Boiler Inspection and Insurance Company.

RESULTS Examinations resulted with the following Recordable Indications being noted on the basis of procedure recording criteria, which are generally more restrictive than specified ASME Boiler and Pressure Vessel Code Section XI Acceptance Standards.

Recordable Indications detected during the 2003 Refueling Outage are listed in Table 1 with a brief summary following. Specific data relative to all Recordable Indications and their dispositions by either corrective measures or acceptance by ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Acceptance Criteria, Repair/Replacement or Evaluation are located in Tab F of the Final Report.

TABLE 1 TYPE OR LOCATION OF RECORDABLE INDICATION (RI) METHOD NO. OF RI'S

  • Reactor Vessel Conoseal Bolting Visual (VT-3) 2 Conoseals
  • 2" Piping Socket Weld Surface (PT) 1 Weld
  • Component Supports and Hangers Visual (VT-3) 12 Supports
  • Valve Bonnet Bolting Visual (VT-3) 6 Valves
  • System Pressure Tests Visual (VT-2) 16 Items
1. A 0.375" long Linear Indication (identified as a Forging Lap) on 2" Socket Weld RTD-W70S was recorded during performance of Liquid Penetrant Examinations. This Linear Indication was Unacceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWB-3514-2. The Linear Indication was reduced in size under Work Order 03-004115 by light filing with a small file, reexamined and Accepted with a 0.100" Linear Acceptable ASME Boiler and Pressure Vessel Code Section X 1989 Edition Table IWB-3514-2 Indication.

Page 3 of 4

2. Visual (VT-1, VT-2 and VT-3) Indications recorded on Reactor Vessel Conoseal Bolting, Steam Generator Primary Side Manway Bolting, Piping Flange Bolting, Valve Bonnet Bolting, Component and Piping Supports and Hangers and during System Pressure Tests were: (1) Evaluated and Accepted or (2) Repaired, Reexamined and Accepted by: Nuclear Management Company, LLC - Maintenance, Quality Control, Engineering and Technical Support or Inservice Inspection Personnel and reviewed by the Authorized Nuclear Inservice Inspector.

SUMMARY

An Inservice Inspection Program Plan was performed at the Kewaunee Nuclear Power Plant from May 8, 2002 through December 5, 2002 (Non Refueling Outage) and April 5, 2003 through May 11, 2003 (Closing of G1 following Refueling Outage) as scheduled in the Kewaunee Nuclear Power Plant Third 10-Year Inservice Inspection (ISI) Program 1994-2004 to continue examinations for the 3rd Interval; 3rd Period. A total of 41 Recordable Indications were detected. All Recordable Indications were Corrected or Accepted by ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Acceptance Criteria, Repair/Replacement or Evaluation.

70X& & &bW IZ.70o3 Phillip . Bukes Date Engineering Programs Inservice Inspection Program Owner Page 4 of 4

ATTACHMENT 7 NUCLEAR MANAGEMENT COMPANY, LLC KEWAUNEE NUCLEAR PLANT DOCKET 50-305 August 6, 2003 Letter from Thomas Coutu (NMC)

To Document Control Desk (NRC)

Examination Summary for Inservice Inspection (ISI) Class MC Proaram

NUCLEAR MANAGEMENT COMPANY, LLC KEWAUNEE NUCLEAR POWER PLANT 1ST INTERVAL: 2ND PERIOD: 2ND OUTAGE 2003 EXAMINATION

SUMMARY

INTRODUCTION An Inservice Inspection (ISI) Program for the Class MC Reactor Building Containment Vessel was performed at the Kewaunee Nuclear Power Plant from April 5, 2003 through May 11, 2003 (Closing of G1 following Refueling Outage) by Kewaunee Nuclear Power Plant examination personnel.

Examinations were performed to satisfy the requirements of:

ASME Boiler and Pressure Vessel Code Section XI 1992 Edition up to and including 1992 Addenda The Inservice Inspection Program Plan located under Tab C was prepared by Nuclear Management Company, LLC - Kewaunee Nuclear Power Plant for the 1st Interval: 2nd Period:

2nd Outage as identified in the Kewaunee Nuclear Power Plant First 10-Year Inservice Inspection (ISI) Program 1996-2006.

The following items were examined for the Class MC Reactor Building Containment Vessel:

  • Accessible Surface Areas
  • Circumferential Weld
  • Airlocks
  • Seals and Gaskets EXAMINATIONS The examinations performed were in accordance with an approved Inservice Inspection Program Plan located under Tab C of the final report. Examination Procedures were approved prior to the start of examinations and certification documents relative to personnel, equipment and materials were reviewed and determined to be satisfactory.

Page 1 of 2

Some of the arrangements and details of the Kewaunee Nuclear Power Plant Components and Piping Systems were designed and fabricated before ASME Boiler and Pressure Vessel Code Section XI Code requirements were established. Examinations performed were intended to examine 100% of the required surface or volume. In some cases, examinations were limited by geometric, metallurgical or design/access restrictions. In each case, the occurrence and cause of the limitation was documented. In all cases the maximum amount achievable was examined.

Witnessing and surveillance of the examinations were conducted by: Hartford Steam Boiler Inspection and Insurance Company.

RESULTS Examinations resulted in No Recordable Indications being noted on the basis of procedure recording criteria, which are generally more restrictive than specified ASME Boiler and Pressure Vessel Code Section XI Acceptance Standards.

SUMMARY

An Inservice Inspection Program for the Class MC Reactor Building Containment Vessel was performed at the Kewaunee Nuclear Power Plant from April 5, 2003 through May 11, 2003 (closing of G1 following Refueling Outage). Examinations were performed as scheduled in the Kewaunee Nuclear Power Plant First 10-Year Inservice Inspection (ISI) Program 1996-2006. Examinations resulted in No Recordable Indications being noted on the basis of procedure recording criteria, which are generally more restrictive than specified ASME Boiler and Pressure Vessel Code Section XI Acceptance Standards.

Ij 1o00o3 Phillip E. Bukes Date Inservice Inspection Program Owner Engineering Programs Page 2 of 2

ATTACHMENT 8 NUCLEAR MANAGEMENT COMPANY, LLC KEWAUNEE NUCLEAR PLANT DOCKET 50-305 August 6, 2003 Letter from Thomas Coutu (NMC)

To Document Control Desk (NRC)

Examination Summary for Steam Generator Eddy Current

0 Kewaunee First ISI Steam Generator Inspection Kewaunee R26 Eddy Current Summary Report April, 2003 1.0 Introduction Kewaunee has completed its 26h refueling cycle (EOC) prior to this inspection. Westinghouse Electric Company was contracted to perform the first eddy current in-service inspection (ISI) of the newly replaced steam generators. The old Westinghouse 51-Model steam generators (SG) were replaced after the 25t fuel cycle with the second generation Westinghouse 54F model steam generators. These new model steam generators incorporate 690 Thermally Treated (TT) Inconel tubing and stainless steel quatrefoil tube support structures (TSP). Each steam generator contains 3592 tubes with an OD of 0.875" OD and a tube wall thickness of 0.050" and 3 chrome plated inconel anti-vibration bars (AVB).

This report will concentrate on the eddy current inspection and results from the analysis.

2.0 Inspection The inspection program for each of the two steam generated consisted of the following:

  • 100%,,o Full-length 720/700 -diameter bobbin coil of all opened tubes.
  • 20% Hot Leg Top of Tubesheet (TTS) 720-diameter 3-Coil +Point RPC (+/- 2 inches)
  • 20% -U-Bend680-diameter +Point RPC of row I (top TSP to top TSP)
  • RPC of all I-codes. dings/dents 5 volts or greater (special interest) and Possible Loose Parts (PLP's)

The eddy current testing began at 02:30 hours on April 17,2002 and the final closeout was completed at 10:18 hours on April 19, 2002.

Data Acquisition was performed simultaneously in each of the two steam generators using the Westinghouse Genesis manipulators, dual probe pushers, and the Zetec MIZ 30 eddy current testers.

The data collection was performed mostly in the automatic mode utilizing the Westinghouse Eddynet software. All testing was performed in accordance with acquisition procedure NMC-400-002 and the parameters established within the Acquisition Examination Technique Specification Sheet (EITS).

The ETSS's established for this inspection were bobbin (NMC-ETSS- 101), RPC +Point TTS (NMC-ETSS-102), and RPC +Point U-bends (NMC-ETSS-103).

Two independent analysis teams (Primary and Secondary) analyzed all the acquired data. The Primary analysis was performed in the manual mode and Secondary analysis in the automatic screening mode.

A third analysis team (Resolution) resolved the discrepancies between these two teams. The resolution team consisted of representatives from both the primary (Westinghouse) and secondary (Zetec) analysis teams. The resolution team was located at the Kewaunee site and utilized the Zetec Eddynet software for resolution analysis for comparing the two independent analyses teams final results. The Primary analysts were located at the Westinghouse REDAC while the Secondary analysts located at the Zetec ZRAF. Both parties utilized the Zetec Eddynet software. All analysis was performed in accordance with the bobbin procedure (NMC400-003), Rotating Coil procedure (NMC-400-004), Independent QDA procedure (NNIC400-006), and SSPD procedure (NMC-400-007).

Primary data management was performed utilizing the Zetec ELMS data management system and secondary data management system was performed by NMC HXR. All data management personnel were located at the Kewaunee site. The data management procedure utilized was NMC400-005.

WPS-01 Rev. 0 April 19, 2003 I of 3

0 Kewaunee First ISI Steam Generator Inspection 3.0 Summary of Findings There was no tube wall degradation detected during this inspection. No tubes needed to be repaired.

Only a small number of benign signals caused by the manufacturing process and possible loose parts (PLP's) were observed and are listed below.

Manufacturing Imperfections All reported bobbin freespan indications were reviewed and compared with the baseline history. Those bobbin free span indications that were detected in baseline and showed no change were reported as FSH. Those bobbin free span indications that either could not be detected in baseline or showed a change from baseline were identified with the appropriate FSI code to be further inspected with the

+Point RPC. None of these freespan indications were indicative by RPC of a crack like morphology and thus requiring no tube repair action during this inspection. The total findings are listed below.

Possible Loose Parts Since the baseline examination a number of signals of possible loose parts (PLP's) were reported by RPC probe during this inspection. All the signals reported were located in the vicinity of the top of the tubesheet. No indication of wear was associated with these PLP's. The total findings are listed below.

The following table summarizes the number of reportable signals from this inspection.

SG A SG B TOTAL FSI I 1 2 FSH 0 3 3 DNG 10 20 30 DNT 8 0 8 BLG 0 2 2 GEO 2 2 4 PLP 8 21 29 Total 29 49 78 Definitions of Codes FSI- Free Span Indication-Used by the resolution analyst for a free span indication that has been reviewed in the baseline data and determined that a change has occurred. RPC is required for deposition of the indication.

FSH- Free Span Indication- Used by the resolution analyst for a free span indication that has been reviewed in the baseline data and determined that a change has not occurred.

DNG- Ding- Condition where the tubing inside diameter has been reduced less than nominal. To be utilized for manufacturing dings reported by the bobbin probe two volts or greater.

DNT- Dent- Condition where the tubing inside diameter has been reduced less than nominal. To be utilized for inservice dents reported by the bobbin probe two volts or greater.

BLG-Bulge- Condition where the tubing inside diameter is greater than nominal. To be used for bulges reported by the bobbin probe two volts or greater.

WPS-01 Rev. 0 April 19, 2003 2of 3

0 Kewaunee First ISI Steam Generator Inspection GEO- Geometry Change- Condition where a signal appears to be caused by a geometry change by the RPC probe. This code used for tracking purposes in future inspections.

PLP-Possible Loose Part- Indicates the possibility of foreign material on the secondary side of the steam generator as reported by the RPC probe.

U-Bend +Point Noise Comparison A comparison study of noise characteristics in all 40 of the row I U-bends (20 in each SG) from 2003 Kewaunee tested with mid range +Point RPC and compared against the data from the virgin U-bend samples used in the EPRI Appendix H qualification for the mid range +Point coil (ETSS # 9651 1.1 and 96511.2). The results of the comparison showed that the measured noise levels in the Kewaunee low row U-bend data are less than the EPRI 96511.1 and 96511.2 avg. noise levels for all tubes tested in every case.

The following table summarizes the Kewaunee average noise levels and compares them to the EPRI ETSS measurments:

KEWAUNEE 2003 LOW ROW U-BEND NOISE STUDY SUNMLLARY I Plus Point RPC noise Measurements performed with window open to one scan line wide.

100 % axial notch set to 35 degrees and 20 volts. Measurements of Vp-p (horizontal) and Vv-m (Vertical) max noise value in U-bend at Apex.

Combined Totals- 40 Row 1 Tubes S/G A and B KEWAUNEE 2003 400 kHz 400 kHz 300 kHz 300 kHz ROW I U-BENDS Vp-p Vv-m Vp-p Vv-m AVG. 0.47 0.13 0.40 0.14 EPRI ETSS 96511 AVG. 1.22 0.41 1.09 0.40 4.0 Other References

1. Authorized Probe List Rev. I April 10, 2003
2. Steam Generator Degradation Assessment for Kewaunee R26 Refueling Outage February 2003 SG-SGDA-03-01 Rev. 0.
3. Appendix H Qualified Techniques at Kewaunee Spring 2003 S/G Inspection April 14,2003 MRS-TRC-1352.

2r is*L William F. Stock Westinghouse Lead Analyst Eddy Current Level III WPS-0I Rev. 0 April 19, 2003 3of 3

ATTACHMENT 9 NUCLEAR MANAGEMENT COMPANY, LLC KEWAUNEE NUCLEAR PLANT DOCKET 50-305 August 6, 2003 Letter from Thomas Coutu (NMC)

To Document Control Desk (NRC)

Examination Summary for Nuclear Regulatory Commission Order EA-03-009

REVISION 1 KEWAUNEE NUCLEAR POWER PLANT 2ND OUTAGE; 3RD PERIOD; 3RD INTERVAL NRC ORDER EA-03-009

SUMMARY

In response to NRC Order EA-03-009, a Reactor Vessel Closure Head Bare Metal Visual Examination of the Forty (40) Reactor Pressure Vessel Head Control Rod Drive Mechanism Penetration Nozzles and one 3/4" Head Vent Penetration Nozzle was performed on April 13, 2003 with No Leakage noted. The Shroud and Insulation was completely removed to permit access. Examiners certified in VT-i, VT-2 and VT-3 Examination Methods to at least Level II, with additional training to the Electric Power Research Institute (EPRI) Visual Examination for Leakage of PWR Reactor Head Penetrations on Top of the RPV Head 1006296 Revision 1, performed the examinations.

High Intensity flashlights qualified to ASME Boiler and Pressure Vessel Code Section XI 1992 Edition 1992 Addenda were utilized in performance of the VT-1 and VT-3 Examinations.

The NIS-1 Owner's Report For Inservice Inspections, NRC Order EA-03-009, Drawings, Examination Results, Personnel and Equipment Certifications, Examination Procedures, Photographs and Lessons learned are included in this Report.

a~e af ft J 003 Phillip E. Bukes Date Inservice Inspection Program Owner

ATTACHMENT 10 NUCLEAR MANAGEMENT COMPANY, LLC KEWAUNEE NUCLEAR PLANT DOCKET 50-305 August 6, 2003 Letter from Thomas Coutu (NMC)

To Document Control Desk (NRC)

Summary of Examinations Which Were Limited by Geometric. Metallurgical, or Design/Access Restrictions and Associated Data Sheets (8 Total)

Docket 50-305 NRC-03-082 August 6, 2003 Attachment 10, Page 1 2003 Summary of Limitations for 2nd Outage, 3d Period, 3rd Interval Inservice Inspection Method of  % Recorded As Not Year Component Identification Examination Examined and Limitation Tubesheet to shell circumferential weld 41.4%: Pipe clamp connected 2003 ARG-W11 on regenerative heat exchanger UT to rigid support bracket assembly 2003 Branch connection weld RC-W50BC on UT 53.0%: Branch nozzle loop B reactor coolant piping configuration Circumferential weld SI-W75 on 12" 50.0%: Valve to elbow 2003 diameter safety injection UT configuration 2003 Circumferential weld SI-W1 19 on 12" UT 50.0%: Elbow to valve diameter safety injection configuration Circumferential weld SI-W47 on 6" UT 50.0%: Pipe to valve 2003 diameter safety injection configuration 2003 Circumferential weld SI-W29 on 6" UT 50.0%: Pipe to nozzle diameter reactor coolant configuration coolant weld RC-W19 on 27.5" ID Circumferential 2003 reactor UT 54.0%:

to Reactor coolant pump pipe configuration

ATTACHMENT 10 PAGE 2 WISCONSIN PUBLIC SERVICE CORPORATION gREV.: ORIG.

KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: RE6"JE R TIRE V hsEr ed/AN6EA /6 4

DRAWING NO.: al 120 f COMPONENT IDENTIFICATION: AR6-w 11 PROCEDURE: NtbN 0 . /5:17 REVISION: ORrG, ULTRASONIC: X LIQUID PENETRANT: __ MAGNETIC PARTICLE: __ VISUAL:

EXAMINER: 1/x2 J.7T; m DATE: q- zs- 0 3 LEVEL EXAMINER: - DATE: Af4 LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE.

No scan 5, scan 7 & 8 limited to weld and downstream base metal only, due to pipe clamp connected to rigid support bracket assembly. Scan 2, 7 & 8, also limited to 90% of length due to welded lugs around circumference of vessel.

Reduced procedural coverage 6228% 1 Reduced code coverage: 414A%

ARG-W11 ne~~~~~k KEWAUNEE NUCLEAR A MA POWER PLANT REVIEW: 7(& e.i9 C DATE: 5 a003 AUTHORIZED NUCLEAR n ,

INSERVICE INSPECTOR REVIEW: - J7t DATE:

ATTACHMENT 10 PAGE 3 WISCONSIN PUBLIC SERVICE CORPORATION I ORIG.

KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: dAC4-Tot dooc4^jTr A,6 Loop 8 DRAWING NO.: ISIM -1i704 COMPONENTIDENTIFICATION: RC -W96tC PROCEDURE: 9gP A). 1S.3S REVISION: & w ULTRASONIC: X LIQUID PENETRANT: __ MAGNETIC PARTICLE: __ VISUAL:

EXAMINER  : _ _ _ _ _ _ _ _ DATE: q //7 C 3 LEVEL EXAMINER: A. Q.-:S/.5- 0-9&- DATE: LI- 17-03

/ LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE.

No scan 2, scan 7 & 8 llmIted to weld and upstream base metal only, due to branch comectlon conrlguatlon.

Reduced procedural coverage: 53%

~~~~~~~-: r~

KEWAUNEE NUCLEAR POWER PLANT REVIEW: C.. i d&W DATE: " AP2^1613 AUTHORIZED NUCLEAR D 23W

_DATE: V-e;; 03 INSERVICE INSPECTOR REVIEW: f;3-_ 1'Ad

ATTACHMENT 10 PAGE A WISCONSIN PUBLIC SERVICE CORPORATION [REV.: ORIG.

KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD fROm cCNrMT PeJ.:10 rM REAc7ZR SYSTEM OR COMPONENT: S1- BrOM ACrTR i6P rc LoOP A CoLAt amc DRAWING NO.: ISIM- - 8-1 COMPONENTIDENTIFICATION: SI- W1S PROCEDURE: NCP-1I.LiI REVISION: A ULTRASONIC: LIQUID PENETRANT:.. MAGNETIC PARTICLE:.. VISUAL:

jj/j A/: IA '

EXAMINER: ___________ DATE: ilt le 7 I V..

LEVEL EXAMINER: A.wi XZ-L i 1I DATE: .5di-zO 3 LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE.

No scan 5, scan 7 & 8 limited to weld and downstream base metal only, due to valve to elbow configuration.

K2-1-.fiA na.Ia rav na. Snows KEWAUNEE NUCLEAR POWER PLANT REVIEW: B C:. 13zt

/e DATE: _______ _

)

AUTHORIZED NUCLEAR ) _

INSERVICE INSPECTOR REVIEW: z,

{faZs

- x DATE: Yeats0 3 g 'I

ATTACHMENT 10 PAGE 5 WISCONSIN PUBLIC SERVICE CORPORATION ORIG.

KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: SI - kouA Aeevufvti^.ox iAs Lo- -A' e.Ua Le-4 DRAWING NO.: IS Im- 193 S-COMPONENT IDENTIFICATION: 51- wJIIl PROCEDURE: AJeP -1s.fl REVISION: -A ULTRASONIC: Y' LIQUID PENETRANT: __ MAGNETIC PARTICLE: __ VISUAL:

EXAMINER: 'I.1. i) e/er DATE: q.21-o'3 LEVEL p.JA EXAMINER: DATE: ,IA LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE.

No scan 2, scan 7 & 8 limited to weld and upstream base metal only, due to elbow to valve configuration.

Drndi enr-u~rn =01d%

Vill

-y";I'

-i I

- , . .P KEWAUNEE NUCLEAR POWER PLANT REVIEW: rev e DATE:

AUTHORIZED NUCLEAR yg c>-P INSERVICE INSPECTOR REVIEW: ho________ / t DATE:_________

ATTACHMENT 10 PAGE 6 WISCONSIN PUBLIC SERVICE CORPORATION REV.: ORIG.

KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEMORCOMPONENT: 3AFcrY £A)Ecriaog F4c.-i cNrlqr P-M'Ia rGo AEPICrcie DRAWING NO.: 15lM- 1379S/

COMPONENTIDENTIFICATION: SL-ijq7 PROCEDURE: AIEP- 15Ytl REVISION: A ULTRASONIC: X LIQUID PENETRANT:__ MAGNETIC PARTICLE:__ VISUAL:

EXAMINER: - DATE: _______

EXAMINER: ______ _ _ DATE: /I/

LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE.

No scan 2, scan 7 & 8 lImited to weld and upstream base meta onl,, due to pIpe to valve confuratlon REDUCED CODE COVERAGE: 60%

SCAN J SCAN 2 -C i-- lSCAN 5 ,rfi In W.~~~~~~~~~I KEWAUNEE NUCLEAR POWER PLANT REVIEW: /°- DATE: oO'°J AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: A DATE:_______

ATTACHMENT 10 PAGE 7 WISCONSIN PUBLIC SERVICE CORPORATION REV.: ORIG.

KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: 51- fRom CNrNer PEN, 2.FN 7n-190A1Te$ AsNA Cct4 Lm Itcc'OS DRAWING NO.: ISLES-?i- ?

COMPONENT IDENTIFICATION: RC - Wz? PROCEDURE: HQP-1S.YlL REVISION: A ULTRASONIC: X LIQUID PENETRANT: __ MAGNETIC PARTICLE: __ VISUAL: _ _

EXAMINER: DATE: YI~21 /02

/ / 4/

Z~~LEVEL EXAMINEFI: A/A A/A4 DATE: A/t LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE.

No scan 2, scan 7 & 8 limited to weld and upstream base metal only, due to pipe to nozzle configuration.

REDUCED CODE COVERAGE: 50%

-l f __

KEWAUNEE NUCLEAR POWER PLANT REVIEW: h-i4 q~73 . &Zk'a/ -

DATE: A 3.30°3 f

AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: DATE: o03 I 14

ATTACHMENT 10 PAGE 8 WISCONSIN PUBLIC SERVICE CORPORATION [Y ORIG.

KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: eAtcTm Coao-l- aps Loooo A DRAWING NO.: 16SM - 1 o3 COMPONENTIDENTIFICATION: V--1Wk\ PROCEDURE: NeP ,Jo. IC '3 REVISION: A ULTRASONIC: X LIQUID PENETRANT: __ MAGNETIC PARTICLE: __ VISUAL:

EXAMINER: A.W. CSeAfSiAI a DATE: '4-21-03 LEVEL EXAMINER: _ _ _ _ _ _ _ _ _ DATE: '/2/ (10.3

"' / LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE.

No scan 5, scan 7 & 8 limited to weld and downstream base metal only, due to pump to pipe configuration.

Reduced procedural coverage: 54%

KEWAUNEE NUCLEAR POWER PLANT REVIEW: -f ro B y4-V DATE: aja, 103 AUTHORIZED NUCLEAR Ad - -e INSERVICE INSPECTOR REVIEW: /'V A DATE: - 22 03