Kewaunee Nuclear Power Plant Point Beach Nuclear Plant N490 Highway 42 6610 Nuclear Road Kewaunee, Wl 54216-9511 Two Rivers, Wl 54241 NM C Committed to NuclearExcellence 920.388.2560 920.755.2321 Kewaunee / Point Beach Nuclear Operated by Nuclear Management Company, LLC NRC-02-015 February 22, 2002 10CFR50.55a U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555 Ladies and Gentlemen:

Docket 50-305 Operating License Kewaunee Nuclear Power Plant 2001 Inservice Inspection (ISI) Summary Report As required by ASME Boiler and Pressure Vessel Code,Section XI; Code of Federal Regulation 10CFR50.55a; and Wisconsin Administrative Code, Subchapter V ILHR 41.55(3) and ILHR 41.56; various ISI examinations were performed as part of the 2001 Refueling Outage. The outage took place from September 24, 2001 through December 4, 2001; i.e. closing of G1. This letter transmits the Inservice Inspection Summary Report as required by paragraph IWA-6230 of Section XI.

Two separate ASME Section XI inservice examination programs are implemented at the KNPP.

One program is for pressure retaining piping/vessel and component supports and the other program for the metal containment. The 2001 refueling outage constituted the first inspection year of the third period of the third interval for the piping/vessel and component support program, including preservice examinations associated with steam generator replacement. The 2001 refueling outage was also the first inspection year of the second period of the first interval for the metal containment program. Examinations for the piping/vessel and component support program, including preservice examinations associated with steam generator replacement, were performed in accordance with the ASME Boiler and Pressure Vessel Code Section XI 1989 Edition. Examinations for the metal containment program were performed in accordance with the 1992 Edition up to and including the 1992 Addenda of Section XI of the ASME Boiler and Pressure Vessel Code. These requirements were implemented in accordance with the "Kewaunee Nuclear Power Plant Third Ten-Year Inservice Inspection (ISI) Program 1994-2004," "Kewaunee Nuclear Power Plant First 10-Year Inservice Inspection Class MC (ISI) Program 1996-2006," Plant Technical Specifications, and nondestructive examination procedures.

Docket 50-305 NRC-02-015 February 22, 2002 Page 2 The following items were examined for Class 1, Class 2, Class 3 Components and their supports:

1. Reactor Vessel Closure Head Flange Weld
2. Reactor Vessel Closure Head Studs, Nuts, Washers and Control Rod Drive Mechanisms
3. Pressurizer Circumferential and Longitudinal Welds
4. Steam Generator Head Circumferential Weld, Nozzle Inside Radius Sections and Nozzle To Shell Weld
5. Reactor Coolant Pump Main Flange Bolting and No. 1 Seal Housing Bolting
6. Seal Water Injection Filter Shell Circumferential Weld
7. Letdown Heat Exchanger Head Circumferential Weld
8. Charging Pump Pulsation Dampener Head Circumferential Weld
9. Class 1 Valve Bodies
10. Class 1 and Class 2 Piping Welds
11. Class 1 Piping Integrally Welded Attachment
12. Class 2 Piping Integrally Welded Attachments
13. Class 2 Safety Injection Pump Casing Weld and Welded Attachments
14. Class 1, Class 2 and Class 3 Piping and Component Supports and Hangers
15. Class 1 and Class 2 Reactor Vessel Conoseal Bolting, Pressurizer Manway Bolting, Flange Bolting and Valve Bonnet Bolting
16. Class 1 System Leakage Test
17. Class 2 and Class 3 System Inservice and Functional System Pressure Tests The following items were examined for the Replacement Steam Generators:
1. Replacement Steam Generators: Tubesheet to Head Welds, Nozzle Inside Radius Sections, Nozzle to Safe End Butt Welds, Primary Side Manway Bolting, Integrally Welded Attachments, Shell Circumferential Welds, Tubesheet to Shell Welds and Class 1 Support Components
2. New Class 1 Reactor Coolant Piping Welds
3. New and Replacement Class 2 Main Steam and Feedwater Piping Welds
4. Reexamination of Existing Steam Generator, Circumferential Welds SG-W2 and SG-W10 to verify previously recorded Ultrasonic Planar Indications
5. Existing 16", 8" and 1" Feedwater Inside Diameter Surfaces
6. Existing Steam Generator Inside Diameter Feedwater Nozzle Inner Radius and Shell Circumferential Welds
7. Existing Steam Generator Class 2 Supports

Docket 50-305 NRC-02-015 February 22, 2002 Page 3 The following items were examined for the Class MC Reactor Building Containment Vessel:

1. Accessible Surface Areas
2. Longitudinal Welds and Circumferential Welds
3. Sleeve to Bellows Welds
4. Flange Welds
5. Seals and Gaskets
6. Moisture Barriers
7. Dissimilar Metal Welds
8. Bolted Connections
9. Containment Penetration Bellows
10. Airlocks The following items were examined in accordance with Kewaunee Nuclear Power Plant Technical Specifications:
1. Eddy Current Testing of Replacement Steam Generators
2. Functional Testing, Disassembly and Overhaul of Steam Generator 900 KIP Hydraulic Snubbers In addition, the following examinations were performed in excess of ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Requirements and included:
1. Portions of the Service Water System were radiographed for wall loss, pits, nodules, and sand, mud or other sediments.
2. Balance of plant piping subject to erosion/corrosion was examined by radiographic, ultransonic, and visual techniques.

Docket 50-305 NRC-02-015 February 22, 2002 Page 4 Please find attached a copy of the following documentation that summarizes the inservice inspection activities and results for the Kewaunee Nuclear Power Plant 2001 Refueling Outage.

1. Summary of recordable indications and a description of how they were dispositioned (Attachment 1)
2. Summary of Class 1 and 2 Repairs and Replacements of Components 1 inch in diameter or smaller (Attachment 2)
3. Form NIS-1 Owner's Report for Inservice Inspections of Class 1, Class 2, and Class 3 Components (Attachment 3)
4. Form NIS-I Owner's Report for Inservice Inspections for Class MC Components (Attachment 4)
5. Form NIS-I Owner's Report for Inservice Inspections of Replacement Steam Generators (Attachment 5)
6. Form NIS-2 Owner's Report for Repair or Replacements (74 Total) (Attachment 6)
7. Examination Summary for Scheduled and Augmented Inservice Inspection (ISI) Program (Attachment 7)
8. Examination Summary for Inservice Inspection (ISI) Class MC Program (Attachment 8)
9. Examination Summary for Preservice Inspection (PSI) of Steam Generators (Attachment 9)
10. Examination Summary for Replacement Steam Generator Eddy Current (Attachment 10)
11. Examination Summary for Steam Generator 900 KIP Hydraulic Snubbers (Attachment 11)
12. A summary of examinations which were limited by geometric, metallurgical, or design/access restrictions and their associated data sheets (Attachment 12)

The final reports for each of these examinations are on file in the QA/QC Records Vault at the Kewaunee Nuclear Power Plant. These records are available for review as deemed necessary.

Additional Comments The next Refueling Outage at the Kewaunee Nuclear Power Plant is tentatively scheduled for April 4, 2003 through April 30, 2003.

Sincerely, Thomas Coutu Manager-Kewaunee Plant PEB/CAT Attach.

cc - U.S. NRC - Region III (w/o attach)

U.S. NRC - Senior Resident Inspector (w/o attach)

ATTACHMENT 1 Letter from T. Coutu (NMC)

To Document Control Desk (NRC)

Dated February 22, 2002 Summary of Recordable Indications and Description of Disposition

Docket 50-305 NRC-02-015 February 22, 2002 , Page 1 TABLE 1 TYPE OR LOCATION OF RECORDABLE i O INDICATION (RI) METHOD NO. OF RI'S Reactor Vessel Closure Head Flange Weld Surface (MT) 1 Weld Steam Generator Circumferential Head Weld Volumetric (UT) 1 Weld Seal Water Injection Filter Shell Weld Volumetric (UT) 1 Weld Piping Integrally Welded Attachment Surface (PT) 1 Weld Piping Circumferential Butt Weld Surface (PT) 1 Weld Piping Socket Weld Surface (PT) 1 Weld Reactor Vessel Conoseal Bolting Visual (VT-3) 1 Conoseal RC Pump No. 1 Seal Housing Bolting Visual (VT-1) 1 Pump Pressurizer Manway Bolting Visual (VT-3) 1 Manway Component Supports and Hangers Visual (VT-3) 31 Supports Valve Bonnet Bolting Visual (VT-1) 1 Valve Valve Bonnet Bolting Visual (VT-3) 6 Valves System Pressure Tests Visual (VT-2) 51 Items Replacement Steam Generator Integrally Welded Surface (MT) 1 Weld Attachment SG-1B-23B Replacement Steam Generator Tubesheet To Head Weld Volumetric (UT) 1 Weld SG-W32 Replacement Steam Generator Primary Side Manway SG- Visual (VT-i) 1 Stud 1B-CLMWB Replacement Steam Generator Tubesheet To Shell Weld Volumetric (UT) I Weld SG-W31 Existing Steam Generator Feedwater Nozzle Inner Radius Surface (MT) 1 Nozzle SG-IR8 Existing Steam Generator Feedwater Nozzle Inner Radius Surface (MT) & 1 Nozzle SG-IR16 Visual (VT-1)

Existing Steam Generator Circumferential Welds SG-W2 Volumetric (UT) 2 Welds and SG-W10 Existing 16", 8" and 1" Feedwater Piping FW-W27BC Surface (MT) 1 ID Section Existing 16", 8", and 1" Feedwater Piping FW-W55BC Surface (MT) & 1 ID Section Visual (VT-1)

Reactor Building Containment Vessel General Visual 11 Plates Reactor Building Containment Vessel Moisture Barriers VT-3 5 Plates Reactor Building Containment Vessel Emergency Airlock VT-1 1 Bolt

Docket 50-305 NRC-02-015 February 22, 2002 , Page 2 Disposition of Class 1, Class 2, and Class 3 indications have been completed in accordance with the rules of ASME Boiler and Pressure Vessel Code Section XI 1989 Edition and ASME Boiler and Pressure Vessel Code Section XI 1992 Edition up to and including 1992 Addenda for Class MC Components. Applicable codes, standards, and engineering criteria were used to disposition indications associated with the non-code-required examinations. Recordable indications for Class 1, Class 2, Class 3 and Class MC have been dispositioned as summarized below:

1. A 0.125" long linear indication was recorded on the Reactor Vessel Closure Head Flange Weld RV-W12 during performance of magnetic particle examination. This linear indication was acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWB-3510-3.
2. A spot indication on Steam Generator 1B Circumferential Head Weld SG-W9 was recorded during performance of ultrasonic examination. This ultrasonic spot indication was acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWC-3510-1.
3. Five (5)laminar indications combined into four (4) laminar indications due to proximity of the indications. The indications are on seal water injection filter IA circumferential shell weld AFSI-Wl and were identified during performance of ultrasonic examinations. These laminar indications were acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWC-3510-2 and were typical of laminations recorded on seal water injection filters 1A and 1B during Refueling Outages 1982, 1986, 1988, 1992 and 1998.
4. Three (3) rounded indications (0.625", 0.125" and 0.1875" in diameter) were recorded on 2" piping integrally welded attachment RSI-H72 during performance of liquid penetrant examinations. These three (3) rounded indications were acceptable per ASME Boiler and Pressure Vessel Code Section III 1989 Edition Section NC-5352(b).
5. A 0.125" long linear indication and a 0.125" rounded indication were recorded on 6" diameter Circumferential Butt Weld ICS-W43 during performance of liquid penetrant examinations. The 0.125" long linear indication was acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWB-3514-2. The 0.125" rounded indication was acceptable per ASME Boiler and Pressure Vessel Code Section III 1989 Edition Section NC-5352.
6. A 0.55" long linear indication on 2" diameter socket weld SI-W6S was recorded during performance of liquid penetrant examinations. This linear indication was unacceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWB-3514-2. The linear indication was removed under Work Order 01-016342 by light filing with a jewelers file, reexamined and accepted with no indications.

Docket 50-305 NRC-02-015 February 22, 2002 Attachment 1, Page 3

7. Visual (VT-1, VT-2 and VT-3) indications were recorded on reactor vessel conoseal bolting, reactor coolant Pump No. 1 seal housing bolting, pressurizer manway bolting, valve bonnet bolting, piping supports and hangers and during system pressure tests. The indications were either (1) evaluated and accepted or (2) repaired, reexamined and accepted by: Nuclear Management Company, LLC - Maintenance, Quality Control, Engineering and Technical Support or Inservice Inspection Personnel and reviewed by the Authorized Nuclear Inservice Inspector.
8. Two (2) separate linear indications on replacement steam generator 1B integrally welded attachment SG-1B-23B were recorded during performance of magnetic particle examinations.

These two linear indications due to their close proximity to each other were classified as one linear indication with a length of 0.21875." This linear indication was acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Sections IWB-3516.1, IWB-3510.3 and IWB-3510-3.

9. Ultrasonic recordable indications at three separate locations on replacement steam generator lB tubesheet to head weld SG-W32 were noted during performance of manual ultrasonic examinations. These three separate planar indications were acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWB-3510-1.
10. One visual indication was recorded by the VT-1 method on replacement steam generator 1B primary side manway stud SG-1B-CLMWB#17. Although this primary manway stud was acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Section IWB-3517.1 (b), a new VT-1 acceptable replacement stud was installed.
11. Ultrasonic recordable indication at one location on replacement steam generator 11B tubesheet to shell weld SG-W31 was noted during performance of manual ultrasonic examination. This planar indication was acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWC-3510-1.
12. Recordable indications on the existing steam generator lB feedwater nozzle inside radius section SG-IR8 were recorded during augmented examination by magnetic particle. These indications were repaired by Bechtel Corporation under Bechtel's NCR's and Kewaunee Nuclear Power Plant Work Orders as part of replacement steam generator activities.
13. Recordable indications on the existing steam generator 1A feedwater nozzle inside radius section SG-IR16 were recorded during augmented examinations by magnetic particle and visual (VT-1) methods. These indications were repaired by Bechtel Corporation under Bechtel's NCR's and Kewaunee Nuclear Power Plant Work Orders as part of replacement steam generator activities.

Docket 50-305 NRC-02-015 February 22, 2002 Attachment 1, Page 4 14/15. Prior to severing the existing steam generators and following welding the replacement steam generators to the existing steam generators a manual ultrasonic examination was performed on the existing circumferential shell welds SG-W2 and SG-W10 to ensure that there was no growth in the previously recorded planar indications. These indications were recorded in 1991 for SG W2 and in 1991 and 1996 for SG-Wl0. All indications previously recorded as well as new indications recorded due to amplitude recording criteria change were acceptable either by ASME Boiler and Pressure Vessel Code Section XI 1989 acceptance standards or by fracture analysis as provided in Westinghouse Electric Corporation WCAP 11476 Rev.3 Handbook on Flaw Evaluation, Kewaunee Unit 1 Steam Generator Upper Shell to Cone Weld, May 1991, and evaluation by Kewaunee Nuclear Power Plant during 1996 and 2001 Refueling Outages.

16. Recordable indications on Loop A existing 16", 8" and 1" feedwater piping inner diameter surface for FW-W27BC were recorded during augmented magnetic particle examinations. These indications were repaired by Bechtel Corporation under Kewaunee Nuclear Power Plant Work Orders generated during steam generator replacement activities.
17. Recordable indications on Loop B existing 16", 8" and 1" feedwater piping inner diameter Surface for FW-W55BC were recorded during augmented examinations by magnetic particle and visual (VT-1) methods. These indications were repaired by Bechtel Corporation under Kewaunee Nuclear Power Plant Work Orders generated during steam generator replacement activities.
18. General visual indication consisting of a 4" x 8" surface defect was recorded on Plate 155. This surface defect was previously recorded and accepted in 1998 and showed no change in dimension or surface condition during the 2001 Refueling Outage.
19. General visual indication consisting of a slight inward bulge on Plates 74, 75, and 83 was recorded. The slight inward bulge was evaluated by Engineering and accepted under Kewaunee Nulcear Power Plant Specification TS-1052, Addendum No. 4, Item No. 19 Section 10.3 - Shell Tolerance.
20. General visual indication consisting of slight outward bulges on Plates 144, 145, 146, 147 and 148 were recorded. The slight outward bulges were evaluated and accepted by Engineering Analysis.
21. General visual indications consisting of weld deposits on Plate 62 and arc strikes on Plate 99 were recorded and are acceptable per ASME Boiler and Pressure Vessel Code Section XI 1992 Edition 1992 Addenda.
22. VT-3 indications consisting of lack of bonding and tears were recorded in the moisture barriers on Plates 62, 64, 65, 66 and 67 and were repaired under Work Order 0 1-018045.
23. A VT-I indication on an emergency airlock bolt was recorded and was repaired under Work Order 01-018283.

ATTACHMENT 2 Letter from T. Coutu (NMC)

To Document Control Desk (NRC)

Dated February 22, 2002 Summary of Class 1 and 2 Repairs and Replacement of Components 1 inch in Diameter or Smaller

Docket 50-305 NRC-02-015 February 22, 2002 , Page 1 The following summarizes the repairs and replacements performed following the 2000 Refueling Outage and during the 2001 Refueling Outage by grinding, buffing, filing, cutting or welding on the Class 1 and Class 2 pressure boundary. These repairs and replacements are in addition to those itemized on the attached Forms "NIS-2 Owner's Report for Repairs or Replacements."

Component Class Reference Repair/Replacement Method 3/4" Valve PS-2A 1 XK-100-10 Cutting and Welding of Replacement Valve 3/4" Valve PS-30 1 XK-100-10 Cutting and Welding of Replacement Valve 1" Valve RC-45A 1 XK-100-10 Cutting and Welding of Replacement Valve and Piping 1" Valve RC-45B 1 XK-100-10 Cutting and Welding of Replacement Valve and Piping Replacement Steam 1 XK-100-10 Repair by Welding Fillet Weld Generator 1B 1/2" Internal Nozzle Drain Line 3/4" Valve 1 XK-100-35 Cutting and Welding of Replacement CVC-21070-1 Valve Replacement Steam 2 M-203 Buffing and Grinding involving Metal Generators 1A and Removal for Arc Strikes, Gouges and 1B: 2", 1" and 3/4" Weld Spatter Piping Replacement Steam 2 M-205 Machining involving Metal Removal for Generators 1A and Pitting 1B Secondary Side Hand Holes

ATTACHMENT 3 Letter from T. Coutu (NMC)

To Document Control Desk (NRC)

Dated February 22, 2002 FORM NIS- 1 Owner's Report for Inservice Inspections of Class 1, Class 2, Class 3 Components

Page 1 of 9 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16,1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Reactor Vessel RV Combustion CE69202 U11480 21010 Engineering Pressurizer PZR Westinghouse 1151 U11402 68-23 Steam Generator SG Westinghouse/ 1141/0202 U11400 68-28/151 1A Ansaldo Energia Milano Steam Generator SG Westinghouse/ 1142/0201 U11401 68-29/150 lB Ansaldo Energia Milano Excess Letdown Heat Sentry 3996-5E U11407 364 Exchanger AHEL-1A Excess Letdown Heat Sentry 3996-6E U11408 365 Exchanger AHEL-1B Class 1 Piping Texas Pipe Bending Reactor Coolant Westinghouse 1A-1-618J871 Pump RCP-1A GO1 Reactor Coolant Westinghouse 1B-2-618J871 Pump RCP-1B G02 Residual Heat Joseph Oat and 1817-1E U11046 344 Exchanger Sons AHRSI-IA

Page 2 of 9 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16, 1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Residual Heat Joseph Oat and 1817-1F U11424 345 Exchanger Sons AHRS2-1B Charging Pump Greer Hydraulics GNI-1848 Pulsation Dampener APD-1A Charging Pump Greer Hydraulics GNI-1846 Pulsation Dampener APD-1B Charging Pump Greer Hydraulics GNI-1847 Pulsation Dampener APD-1C Seal Water Heat Atlas 734 U11404 596 Exchanger AHSW Volume Control Tank Joseph Oat and 1787-1C U11425 376 VCT Sons Regenerative Heat Joseph Oat and 1831-13 U11409 413 Exchanger ARG Sons U11410 414 U11411 415 Letdown Heat Atlas 1206 U11405 1031 Exchanger AHLD

Page 3 of 9 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16,1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

101072 1172 Seal Water Injection Commercial Filter AFSI-1A Filters Seal Water Injection Commercial 101073 1173 Filter AFSI-1B Filters Reactor Coolant AMF Cuno 121 2616 Filter AFRC Seal Water Filter AMF Cuno 123 2618 AFSW Class 2 Piping Texas Pipe Bending Charging Pump Ajax Iron Works 6578 APCH-1A Charging Pump Ajax Iron Works 6576 APCH-1B Charging Pump Ajax Iron Works 6577 APCH-1C Charging Pump Greer Hydraulics GH1-10234 568 APCH-1A Suction Stabilizer

Page 4 of 9 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16,1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Charging Pump Greer Hydraulics GH1-10235 569 APCH-1B Suction Stablizer Charging Pump Greer Hydraulics GH1-10236 570 APCH-1C Suction Stablizer Residual Heat Byron Jackson 681N0277 Removal Pump APRHI-IA Residual Heat Byron Jackson 681N0276 Removal Pump APRH2-1B Refueling Water General American C-8297/1969 Storage Tank Transportation Company Diesel Generator ITT Standard 750797-01-2 AHDG-1A Cooling Corp. &

Water Exchangers (2) 750797-01-3 Diesel Generator ITT Standard 750797-01-1 Corp. &

AHDG-1B Cooling 750797-01-4 Water Exchangers (2)

Page 5 of 9 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16,1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Auxiliary Feedwater Pacific Pump 46573 Pump APFM-1A Motor Driven Auxiliary Feedwater Pacific Pump 46574 Pump APFM-1B Motor Driven Auxiliary Feedwater Pacific Pump 46575 Pump APFT Turbine Driven Class 3 Piping Texas Pipe Bending Containment Fan Joy GF14402 Cooler AHCF-1A Manufacturing and American Air Filter Containment Fan Joy GF14399 Cooler AHCF-1B Manufacturing and American Air Filter

Page 6 of 9 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16, 1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Containment Fan Joy GF14401 Cooler AHCF-1C Manufacturing and American Air Filter Containment Fan Joy GF14400 Cooler AHCF-1D Manufacturing and American Air Filter Safety Injection Bingham Pump 290696 Pump APSI-1A Safety Injection Bingham Pump 290697 Pump APSI-1B Safety Injection Thermxchanger X10199A2 Pump Lube Oil Cooler AHSC-1A Safety Injection Thermxchanger X10199A3 Pump Lube Oil Cooler AHSC-1B Safety Injection Borg Warner 854030:854030 Pump Heat Exchangers (2)

AHSC-1A

Page 7 of 9 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16, 1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Safety Injection Borg Warner 854030:854030 Pump Heat Exchangers (2)

AHSC-1B Residual Heat Borg Warner 681N0276 Removal Pump AHRLRP-1A Shaft Seal Heat Exchanger Residual Heat Borg Warner 681N0276 Removal Pump AHRHRP-1B Shaft Seal Heat Exchanger Accumulator Tank Wyatt H-5645-69 U11397 ACC-1A Accumulator Tank Wyatt H-5644-69 U11398 ACC-1B Containment Spray Ingersoll Rand 0670-74 Pump APCS-1A Containment Spray Ingersoll Rand 0670-75 Pump APCS-1B Containment Spray Helliflow 49486938 Pump AIPCS-1A Gland Seal Cooler

Page 8 of 9 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16, 1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Containment Spray Helliflow 6080694 Pump APCS-1B Gland Seal Cooler Component Cooling Ingersoll Dresser 0600009 Pump APCC-1A Pump Flow Serv.

Component Cooling Ingersoll Dresser 0600010 Pump APCC-1B Pump Flow Serv.

Service Water Pump Worthington VTP27737 APSW-1A1 Pump Service Water Pump Worthington 75 TU-1719-1 APSW-1A2 Pump Service Water Pump Worthington VTP27736 APSW-1B1 Pump Service Water Pump Worthington VTP27739 APSW-1B2 Pump Spent Fuel Pool Heat Struther Wells 1-68-06-1519 U11445 Exchanger AHSF Main Steam Moisture Wright Austin 6230 X.R. 6008 Separator Spent Fuel Pool Gould Pumps 786A519.1 Pump APSF-1A

Page 9 of 9 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16, 1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Spent Fuel Pool Gould Pumps 786A519.2 Pump APSF-1B Service Water Pump S.P. Kinney 2278 Strainer ASSW-1A1 Engineers Service Water Pump S.P. Kinney 2279 Strainer ASSW-1A2 Engineers Service Water Pump S.P. Kinney 2280 Strainer ASSW-1B1 Engineers Service Water Pump S.P. Kinney 2281 Strainer ASSW-1B2 Engineers Component Cooling Engineers and S-15748-A U11426 1139 Heat Exchanger Fabricators AHCC1-IA Component Cooling Engineers and S-15748-B U11427 1140 Heat Exchanger Fabricators AHCC2-1B

FORM NIS-1 (Back)

8. Examination Dates March 27,2001 to December 6, 2001
9. Inspection Period Identification 3rd 3rd
10. Inspection Interval Identification 1989 None 1989 Addenda
11. Applicable Edition of Section XI November 27,2000/Revision 2
12. Date/Revision of Inspection Plan
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. Reference Tab C
14. Abstract of Results of Examinations and Tests. Reference Tab B and Tab F
15. Abstract of Corrective Measures. Reference Tab B and Tab F Utilization of ASME Boiler and Pressure Vessel Code Section XI:

Code Cases N-416-1, N-416-2, N-460, N-491, N-498 and N-498-1.

We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASMIE Code,Section X.

Certificate of Authorization No. (if applicable) '",/-' Expiration Date Date .- K o Signed W Z - 4A1e.. , cua-'u By~- A J 20 Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of W1I.OwNSiA and employed by NAxt-r-Fato SrmA, Lci', -r" of 4AA'rgoi*o C.-. have inspected the components described in this Owner's Report during the period AfAR*,.4 ,'-7, ,avo/ to -e, , , and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4 ,-__ Commissions A"'72 / eo190s/ 11( /-4 -*'T s 6Signature National Board, State. Province, and Endorsements A3 A Date

ATTACHMENT 4 Letter from T. Coutu (NMC)

To Document Control Desk (NRC)

Dated February 22, 2002 FORM NIS- 1 Owner's Report for Inservice Inspections for Class MC Compenents

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16,1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Reactor Building Chicago Bridge C4454 U11423 Containment Vessel and Iron Company Personnel Airlock Chicago Bridge C4454 U11423 and Iron Company

FORM NIS-1 (Back)

September 18, 2001 to December 4, 2001 8, Examination Dates

9. Inspection Period Identification 2nd 1st
10. Inspection Interval Identification
11. Applicable Edition of Section XI 1992

______________Addenda 1992 September 26, 2000/Revision 1

12. Date/Revision of Inspection Plan
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. Reference Tab C
14. Abstract of Results of Examinations and Tests. Reference Tab B and Tab F
15. Abstract of Corrective Measures. Reference Tab B and Tab F We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code, Section

)a.

Certificate of Authorization No. (if applicable) Expiration Date Signed WI p5 6-j~c_ e-c By Date A a J Q3 2,1, Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of __ _ ___ ___ ___and employed by //A r10F*e ) ,7-6AbM13 It- r f

/4CAR7"FI Cr have inspected the components described in this Owner's Report during the period

/e Rdi001 t IOV,200 ' , and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or con:a with t inspecion.

Commissions ,,.'4 " '/A./S / 2", 'V, '4 National Board. State, Province. and Endorsements

ATTACHMENT 5 Letter from T. Coutu (NMC)

To Document Control Desk (NRC)

Dated February 22, 2002 FORM NIS-1 Owner's Report for Inservice Inspections of Replacement Steam Generators

Page 1 of 2 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16, 1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Steam Generator SG Ansaldo Energia 0202 U11400 151 1A Milano Steam Generator SG Ansaldo Energia 0201 U11401 150 1B Milano Steam Generator SG Westinghouse 1141 U11400 68-28 1A Steam Generator SG Westinghouse 1142 U11401 68-29 lB Steam Generator IA Ansaldo Energia NA NA NA Safe End Welds Milano Steam Generator 1B Ansaldo Energia NA NA NA Safe End Welds Milano Class 1 Reactor Bechtel NA NA NA Coolant Piping Corporation Installation Welds Class 2 Main Steam Bechtel NA NA NA Piping Installation Corporation Welds

Page 2 of 2 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307- 9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16,1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

MANUFACTURER COMPONENT OR MANUFACTURER OR INSTALLER STATE OR NATIONAL APPURTENANCE OR INSTALLER SERIAL NO. PROVINCE NO. BOARD NO.

Class 2 Feedwater Bechtel NA NA NA Piping Installation Corporation Welds Class 2 Feedwater Bechtel NA NA NA Nozzle Adapter and Corporation Nozzle to Pipe Installation Welds

FORM NIS-1 (Back)

8. Examination Dates June 4, 2001 December 4, 2001 3rd
9. Inspection Period Identification 3rd
10. Inspection Interval Identification 1989 None 1989 Addenda
11. Applicable Edition of Section XI November 27, 2000/Revision 2
12. Date/Revision of Inspection Plan
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. Reference Tab C
14. Abstract of Results of Examinations and Tests. Reference Tab B and Tab F
15. Abstract of Corrective Measures. Reference Tab B and Tab F Utilization of ASME Boiler and Pressure Vessel Code Section XI: Code Cases N-416-2 and N-460.

We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable) Expiration Date /

Date a\.JA4 CC, A.VQ3~*QO Signed C-)JI I'~ L~. By J Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of 0A:i.o C-0 I,.-

"T and employed by HA./,-rgao ST4Mi Boller CTr. of 4-e1-/o,'e-) r r" have inspected the components described in this Owner's Report during the period

,&,Tte, ,, ,0 O/ to A '9"/, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or cone wit this inspection.

Commissions / 79" V/ Al/.S /OO"at XZ !ý A 4., J c, Actor's

. Signature National Board. State. Province. and Endorsements V

ATTACHMENT 6 Letter from T. Coutu (NMC)

To Document Control Desk (NRC)

Dated February 22, 2002 FORM NIS-2 Owner's Report for Repair or Replacement (74 Total)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl Date 11/1/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-016956 N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp N..A
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson. Wisconsin 54016 Authorization No. NA Expiration Date NA
4. Identification of System 33 Class 2 SAFETY INJECTION Code Case NA
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section X1 Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Repaired, ASME Year Replaced, or Code Name of Name of Manufacturer National Other Board No. ID Built Replacement Stamped Component Manufacturer Serial No.

NA NA 1967 REPAIRED N N

RSI-H70 ITT GRINNELL VALVE NA COMPANY

7. Description of Work REPAIR CLASS 2 SAFETY INJECTION SYSTEM 2" HANGER RSI-H70 DUE TO MISSING JAM NUT.
8. Tests conducted Hydrostatic D Pneumatic F Nominal Operating Pressure D: Exempt 17 Other DJ Pressure psi Test Temp. deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 11/1/2001 Name of Component: RSI-H70 Work Order Number: 01-016956 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XL. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed & Date 20 0A Designee, Title Owner or Owner's Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors CT and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, to /-3/1 , and state that have inspected the components described in the Owner's Report during the period 7-;5'i0" to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

concerning By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, nor the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

  • *
  • Commissions NB7741, I,N, IS, A WIS 100024 National Board, State, Province, and Endorsements pectors nature

.20 _____

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 11/1/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-016956 N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC Authorization No. NA 700 First Street, Hudson, Wisconsin 54016 Expiration Date N.A
4. Identification of System 33 Class 2 SAFETY INJECTION Code Case NAA
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, AM Repairedl,or ASME Code Replaced, Manufacturer National Other Year Stamped Name of Name of Board No. ID Built Replacement Manufacturer Serial No.

Component

'4 NA NA 1967 XtzHAIh(tU RSI-H73 ITT GRINNELL VALVE NA NA NA 1967 REPAIRED COMPANY UNSPREAD COTTER PIN.

7. Description of Work REPAIR CLASS 2 SAFETY INJECTION SYSTEM 2" HANGER RSI-H73 DUE TO
8. Tests conducted Hydrostatic El Pneumatic El Nominal Operating Pressure

--] Exempt deg. F Other n Pressure psi Test Temp.

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: . 11/1/2001 Name of Component: RSI-H73 Work Order Number: 01-016956 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed . *Jg? ZSA4*V Ao it. J OL, M Date ,20 L Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7- ,T-" to /- -3/-02., and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

s uCommissions NB7741, I, N, IS, A WIS 100024 pectors Signature National Board, State, Province, and Endorsements Date * .-20 o'-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 11/1 /2001

1. Owner Wisconsin Public Service Corporation of 2 Sheet 1 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant 01-016956 Work Order N490 HWY 42 Kewaunee. WI 54216-9511 Sym. Stamp NA Type Code
3. Work Performed By Nuclear Management Company, LLC nNo. NA 700 First Street, Hudson, Wisconsin 54016 Authorizatio late NA 33 Class 2_ SAFETY INJECTION Expiration D
4. Identification of System NA Code Case
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components MIYI Repa*ired,or Code Year Replaced, Name of Name of Manufacturer National Other Replacement Stamped Board No. ID Built Serial No.

Component Manufacturer NA 1967 REPAIIU ITT GRINNELL VALVE NA NA NA 1967 REPAIRED RSI-H74 COMPANY NUT.

7. Description of Work REPAIR CLASS 2 SAFETY INJECTION 2" HANGER RSI-H74 DUE TO LOOSE Pneumatic F Nominal Operating Pressure
8. Tests conducted Hydrostatic El Exempt [-7 psi Test Temp. deg. F Other D Pressure
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 11/1/2001 Name of Component: RSI-H74 Work Order Number: 01-016956 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed 44& L-"O Date 4Ak M ,20 0 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7--V-1V to /-*i"-2,, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4 12 .,0 Commissions NB7741, I, N, IS, A WIS 100024 National Board, State, Province, and Endorsements t nspector's ,2nature Dae-20 ___

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 11/16/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant 01-018043 Work Order N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC Authorization No. NA 700 First Street, Hudson. Wisconsin 54016 Expiration Date NNA
4. Identification of System 05A Class 2 FEEDWATER Code Case NA
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section X1 Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components NepI[u, MOIViE Repaired,or Replaced, Code Manufacturer National Other Year Stamped Name of Name of ID Built Replacement Serial No. Board No.

Component Manufacturer 1967 REPAI RED N NA ITT GRINNEL NF NA NA 1967 REPAI RED IN FDW-H170 COMPANY NUTS.

7. Description of Work REPAIR CLASS 2 FEEDWATER SYSTEM 16" SUPPORT FDW-H170 DUE TO LOOSE
8. Tests conducted Hydrostatic F Pneumatic D-] Nominal Operating Pressure 1:1 Exempt E' Other D Pressure psi Test Temp. deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 11/16/2001 Name of Component: FDW-H170 Work Order Number: 01-018043 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed PC/W.t"J .VJ.,l.W.dI0, V2l"J Date * ,20 a Designee, Title Owner or Owner's Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors CT and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, 7-.2)VP to /-/-#1, and state that have inspected the components described in the Owner's Report during the period measures described to the best of my knowledge and belief, the Owner has performed examinations and taken corrective in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

or implied, concerning By signing this certificate neither the Inspector nor his employer makes any warranty, expressed the Inspector nor the examinations and corrective measures described in this Owners Report. Furthermore, neither any kind arising his employer shall be liable in any manner for any personal injury or property damage or a loss of from or connected with this inspection.

""-" Commissions NB7741, I,N, IS, A WIS 100024 National Board, State, Province, and Endorsements

ýnspectors ý4nature Date / 20 -__ _

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 11/16/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-018044 N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp N.A
3. Work Performed By Nuclear Management Company, LLC Authorization No. NA 700 First Street, Hudson, Wisconsin 54016 Expiration Date NA
4. Identification of System 05B Class 2 AUXILIARY FEEDWATER Code Case NA
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Repaired, ASME Code Year Replaced, or Name of Name of Manufacturer National Other Stamped Board No. ID Built Replacement Component Manufacturer Serial No.

1967 REPAIRED N NA NA NA NA 1967 REPAIRED N FDW-H39 ITT GRINNEL COMPANY

7. Description of Work REPAIR CLASS 2 AUXILIARY FEEDWATER SYSTEM 3" HANGER FDW-H39 DUE TO LOOSE NUT ON PIPE CLAMP.
8. Tests conducted Hydrostatic El Pneumatic Nominal Operating Pressure D: Exempt []

psi Test Temp. deg. F Other F Pressure

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 11/16/2001 Name of Component: FDW-H39 Work Order Number: 01-018044 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed Y g%/e, /1kA/1A41WJ5KZ1 MAMA I Owner or Owner's Designee, Title owrj Looj&ýDate _ 20 OX Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors Co. of Hartford, CT and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins.

to /- 31-OZ , and state that have inspected the components described in the Owner's Report during the period 7- 2y-i" measures described to the best of my knowledge and belief, the Owner has performed examinations and taken corrective in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

concerning By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, the Inspector nor the examinations and corrective measures described in this Owner's Report. Furthermore, neither kind arising his employer shall be liable in any manner for any personal injury or property damage or a loss of any from or connected with this inspection.

Commissions NB7741, I,N, IS, A WIS 100024 National Board, State, Province, and Endorsements Inspector's S;(nature Date-e / ,20 D

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 11/15/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-018044 N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp NA.
3. Work Performed By Nuclear Management Company, LLC Authorization No. NA 700 First Street, Hudson, Wisconsin 54016 Expiration Date NA
4. Identification of System 05B Class 2 AUXILIARY FEEDWATER Code Case NA
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASM E Repaired,or ASME Code Other Year Replaced, Name of Name of Manufacturer National Replacement Stamped Board No. ID Built Manufacturer Serial No.

Component I"

NA NA 1967 KHAlU IN FDW-H43 ITT GRINNEL NA NA NA 1967 REPAIRED COMPANY TO LOOSE NUT ON THE PIPE

7. Description of Work REPAIR CLASS 2 AUXILAIRY FEEDWATER SYSTEM 3" HANGER FDW-H43 DUE CLAMP.

Nominal Operating Pressure

8. Tests conducted Hydrostatic ]

Pneumatic Li n Exempt r*

deg. F Other [ Pressure psi Test Temp.

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 11/15/2001 Name of Component: FDW-H43 Work Order Number: 01-018044 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed ___ __ _2Dat Date__ 2 tQ U

Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period '7-o.rOe to 1-3t-OZ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning nor the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I,N, IS, A WIS 100024 Inspector Signature National Board, State, Province, and Endorsements Date / 20 0 L"

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section X1 Date 11/16/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-018044 N490 HWY 42 Kewaunee. WI 54216-9511 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA Expiration Date NA
4. Identification of System 05B Class 2 AUXILIARY FEEDWATER Code Case NA
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Repaired, ASME Manufacturer National Other Year Replaced, or Code Name of Name of Stamped Serial No. Board No. ID Built Replacement Component Manufacturer NA 1967 REPAIRED N

N ITT GRINNEL NA NA FDW-H44 COMPANY

7. Description of Work REPAIR CLASS 2 AUXILAIRY FEEDWATER SYSTEM 3" HANGER FDW-H44 DUE TO LOOSE NUT ON THE PIPE CLAMP.

Exempt El

8. Tests conducted Hydrostatic Pneumatic Nominal Operating Pressure 0l Other D Pressure psi Test Temp. deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 11/16/2001 Name of Component: FDW-H44 Work Order Number: 01-018044 Certificate of Compliance REPAIRED conforms to the rules of the We Certify that the statements made in the report are correct and this ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed Iý  ?,- * (0.l~'l4/ Date**".i~at*-/--'4*P Dh6t4 ,20 OcL Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION Inspectors I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Ins. Co. of Hartford, CT and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and to / -* ,and state that have inspected the components described in the Owner's Report during the period '7--F-7 measures described to the best of my knowledge and belief, the Owner has performed examinations and taken corrective in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

or implied, concerning By signing this certificate neither the Inspector nor his employer makes any warranty, expressed the Inspector nor the examinations and corrective measures described in this Owner's Report. Furthermore, neither kind arising his employer shall be liable in any manner for any personal injury or property damage or a loss of any from or connected with this inspection.

  • 4, Commissions NB7741, I,N, IS, A WIS 100024 nspector's Signa ure National Board, State, Province, and Endorsements Date / 20 ___'-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corooration Date 11/24/2001 Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-018045 N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp N.*A
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA Expiration Date NA
4. Identification of System 89A Class MC BUILDINGS - STRUCTURES
5. (a) Applicable Construction Code SEC. Il-CL.B-1965W Code Case NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 ADDENDA
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Serial No. Board No. ID Built Replacement Stamped Component Manufacturer RBCV CHICAGO BRIDGE AND C4454 NA 1S-0002 1969 REPAIRED Y IRON
7. Description of Work REPAIR CLASS MC (METAL CONTAINMENT) REACTOR BUILDING CONTAINMENT VESSEL MOISTURE BARRIER BONDING BETWEEN ELEVATION 606' AND METAL CONTAINMENT.
8. Tests conducted Hydrostatic Dl Pneumatic D- Nominal Operating Pressure Exempt Li Other 1 Pressure psi Test Temp. deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 11/24/2001 Name of Component: RBCV Work Order Number: 01-018045 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed.20 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period T'7-Ar'- to /-31-03-, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I,N, IS, A WIS 100024 nspector's nature National Board, State, Province, and Endorsements Date / ,20 D,..

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 12/1/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-018277 N490 HWY 42 Kewaunee. WI 54216-9511 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC Authorization No. NA 700 First Street, Hudson, Wisconsin 54016 Expiration Date NA
4. Identification of System 33 Class 1 SAFETY INJECTION Code Case NA
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Ipiru, P.IVIE Repaired,or Replaced, Code Manufacturer National Other Year Name of Name of Built Replacement Stamped Serial No. Board No. ID Component Manufacturer 1967 RPLACMN I N S1116-002 VELAN VALVE NF NA S1 116-002 1967 REPLACEMENT N S1-13B CORPORATION HOLE LEAKS IN THE SEAL WELD
7. Description of Work REPAIR CLASS 1 6" SAFETY INJECTION SYSTEM VALVE SI-13B DUE TO 4 PIN INCLUDING REPLACING 4 STUDS.
8. Tests conducted Hydrostatic El Pneumatic " Nominal Operating Pressure Exempt F Other D] Pressure 2240 psi Test Temp. f55 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 12/1/2001 Name of Component: S1-13B Work Order Number: 01-018277 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed . &UN44w

  • d Date L 20 Q Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION Inspectors I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel CT and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, 7-15r-,90' to /- 3/-, and state that have inspected the components described in the Owner's Report during the period described to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

or implied, concerning By signing this certificate neither the Inspector nor his employer makes any warranty, expressed the Inspector nor the examinations and corrective measures described in this Owner's Report. Furthermore, neither loss of any kind arising his employer shall be liable in any manner for any personal injury or property damage or a from or connected with this inspection.

Commissions NB7741, N, IS, A I1 WIS 100024 ignature National Board, State, Province, and Endorsements Inspector's Date / ,20 0,__

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 11/21/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-018283 N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC Authorization No. NA 700 First Street. Hudson, Wisconsin 54016 Expiration Date NA
4. Identification of System 89A Class MC BUILDINGS - STRUCTURES Code Case NA
5. (a) Applicable Construction Code SEC. III-CL.B-1965W (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 ADDENDA
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Repaired,or ASME Code Replaced, Name of Manufacturer National Other Year Name of ID Built Replacement Stamped Serial No. Board No.

Component Manufacturer I

NA 1S-0002 1969 t.MAI tU C4454 NA 1S-0002 1969 REPAIRED ,f EMRG. CHICAGO BRIDGE AND AIRLOCK IRON

7. Description of Work REPAIR CLASS MC METAL CONATINMENT EMERGENCY AIRLOCK DUE TO BOLT NOT FLUSH WITH SURFACE.

Exempt Li

8. Tests conducted Hydrostatic El Pneumatic R7 Nominal Operating Pressure deg. F Other F" Pressure psi Test Temp.
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 11/21/2001 Name of Component: EMRG. AIRLOCK Work Order Number: 01-018283 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed * * **1 Date - " ,20 Oý Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-23-'o to -3/-,2. , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

.-,Commissions 7ýý NB7741, 1, N, IS, A WIS 100024 pector's Si" ature National Board, State, Province, and Endorsements Date ;1"- -. .20 __ _._.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 12/1/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-018402 N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA Expiration Date NA
4. Identification of System 33 Class 1 SAFETY INJECTION Code Case NA
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Repaired, ASME Replaced, or Code Name of Name of Manufacturer National Other Year ID Built Replacement Stamped Serial No. Board No.

Component Manufacturer 1967 REPAIRED N S1-13B VELAN VALVE NF NA S1116-002 1967 REPAIRED N CORPORATION

7. Description of Work REMOVE GOUGES AND PREPARE GASKET SURFACE OF CLASS 1SAFETY INJECTION SYSTEM 6" VALVE SI 13B BONNET SURFACE.

Nominal Operating Pressure Exempt

8. Tests conducted Hydrostatic Pneumatic El j Pressure 2240 psi Test Temp. 551 deg. F Other
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 12/1/2001 Name of Component: SI-13B Work Order Number: 01-018402 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed " Owwvf Date .20 Title Owner or Owner's Designee, Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period "7-21o-ap to __3_-9__ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, 1,N, IS, A WIS 100024 Inspectors ignature National Board, State, Province, and Endorsements Da tee 20 99,A

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 11/26/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-018522 N490 HWY 42 Kewaunee. WI 54216-9511 Type Code Sym. Stamp NA.
3. Work Performed By Nuclear Management Company, LLC Authorization No. NA 700 First Street, Hudson, Wisconsin 54016 Expiration Date NA
4. Identification of System 34 Class 2 RESIDUAL HEAT REMOVAL Code Case NNA
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Hepaired, AML Repaired, ASME Code Other Year Replaced, or Name of Name of Manufacturer National Stamped Board No. ID Built Replacement Component Manufacturer Serial No.

1967 REPAIRED N ITT GRINNELL VALVE NA NA NA 1967 REPAIRED IN RHR-H18 COMPANY SCALE.

7. Description of Work REPAIR CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM 8" HANGER RHR-H18 DUE TO LOAD SETTING OF
8. Tests conducted Hydrostatic " Pneumatic - Nominal Operating Pressure D: Exempt El deg. F Other n Pressure psi Test Temp.
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 11/26/2001 Name of Component: RHR-H18 Work Order Number: 01-018522 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed P - -- eOU Date 20 0 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-0.S'- C.V to ________ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

,1 -ý7ý Commissions NB7741, I,N, IS, A WIS 100024 National Board, State, Province, and Endorsements

-- lnspector's S(nature Date- ,'/ ,20 9 5L a7

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl Date 11/26/2001

1. Owner Wisconsin Public Service Corporation Sheet I of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-018522 N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp N__A
3. Work Performed By Nuclear Management Company, LLC Authorization No. NA 700 First Street, Hudson, Wisconsin 54016 Expiration Date NA
4. Identification of System 34 Class 2 RESIDUAL HEAT REMOVAL Code Case NA
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Kepalreo, AM Repaired,or Replaced, Code Name of Name of Manufacturer National Other Year Stamped ID Built Replacement Serial No. Board No.

Component Manufacturer 1967 REPAIRED N NA RHR-H24 ITT GRINNELL VALVE NA NA NA 1967 REPAIRED N COMPANY OF

7. Description of Work REPAIR CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM 8" HANGER RHR-H24 DUE TO MISALIGNMENT SUPPORT.
8. Tests conducted Hydrostatic Pneumatic F1 Nominal Operating Pressure D:

Exempt E deg. F Other F] Pressure psi Test Temp.

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 11/26/2001 Name of Component: RHR-H24 Work Order Number: 01-018522 Certificate of Compliance REPAIRED conforms to the rules of the We Certify that the statements made in the report are correct and this ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed Date 20 0.1 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION Vessel Inspectors I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure and Ins. Co. of Hartford, CT and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection have inspected the components described in the Owner's Report during the period 7-,Sr-6' to /- .3/'-OZ, and state that corrective measures described to the best of my knowledge and belief, the Owner has performed examinations and taken in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

or implied, concerning By signing this certificate neither the Inspector nor his employer makes any warranty, expressed neither the Inspector nor the examinations and corrective measures described in this Owner's Report. Furthermore, of any kind arising his employer shall be liable in any manner for any personal injury or property damage or a loss from or connected with this inspection.

nsp.Commissions C NB7741, I,N, IS, A WIS 100024 re National Board, State, Province, and Endorsements nspector's Sig Da ate7* *4 20 0

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 11/26/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-018525 N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA Expiration Date NA
4. Identification of System 33 Class 1 SAFETY INJECTION Code Case NA
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Repaired, ASME Year Replaced, or Code Name of Name of Manufacturer National Other Built Replacement Stamped Serial No. Board No. ID Component Manufacturer 1967 REPAIRED N NA NA NA NA 1967 REPAIRED N RSI-H7 ITT GRINNELL VALVE CO.
7. Description of Work REPAIR CLASS 1 SAFETY INJECTION SYSTEM 2" SUPPORT RSI-H7 DUE TO DAMAGED SPRING CAN.
8. Tests conducted Hydrostatic [] Pneumatic R Nominal Operating Pressure D3 Exempt 17 psi Test Temp. deg. F Other F Pressure
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 11/26/2001 Name of Component: RSI-H7 Work Order Number: 01-018525 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed /4.,6 t I.TIVA*OffN ,O"m,.Date JA,20 _.L_

Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period I.- 29.'-P to /- 3/-0 ZI., and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

9 sp tCommissions NB7741, I, N, IS, A WIS 100024 ospector's SiLgature National Board, State, Province, and Endorsements Date 20 01:4-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 12/19/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant 01-018670 Work Order N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC Authorization No. NA 700 First Street. Hudson, Wisconsin 54016 Expiration Date NA
4. Identification of System 34 Class 2 RESIDUAL HEAT REMOVAL Code Case NA
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components ICepaireu, MIVI R~epaired,or Replaced, Code Name of Name of Manufacturer National Other Year Stamped ID Built Replacement Serial No. Board No.

Component Manufacturer REPAIRED N AC034-002 1972 CRANE NF NA AC034-002 1972 REPAIRED N RHR-3B COMPANY HEAT REMOVAL SYSTEM 8"

7. Description of Work REPAIR BONNET TO BODY LEAK BY TORQUING BOLTING ON CLASS 2 RESIDUAL VALVE RHR-3B.

Exempt F*

8. Tests conducted Hydrostatic R Pneumatic D Nominal Operating Pressure E]

psi Test Temp. deg. F Other D Pressure

9. Remarks NOT APPLICABLE.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 12/19/2001 Name of Component: RHR-3B Work Order Number: 01-018670 Certificate of Compliance REPAIRED conforms to the rules of the We Certify that the statements made in the report are correct and this ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA (O Date 20 Q2 Signed Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION and Pressure Vessel Inspectors I, the undersigned, holding a valid commission issued by the National Board of Boiler and Ins. Co. of Hartford, CT and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection 7-;r-00 to I/-3zNC , and state that have inspected the components described in the Owner's Report during the period and taken corrective measures described to the best of my knowledge and belief, the Owner has performed examinations XI.

in this Owner's Report in accordance with the requirements of the ASME Code, Section expressed or implied, concerning By signing this certificate neither the Inspector nor his employer makes any warranty, neither the Inspector nor the examinations and corrective measures described in this Owner's Report. Furthermore, or a loss of any kind arising his employer shall be liable in any manner for any personal injury or property damage from or connected with this inspection.

Commissions NB7741, I,N, IS, A WIS 100024 Inspecors naNational Board, State, Province, and Endorsements Date d, ,/ ,20 O,-P

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl Date 12/1/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 97-212982 N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA Expiration Date NA
4. Identification of System 33 Class 2 SAFETY INJECTION Code Case NA
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME National Other Year Replaced, or Code Name of Name of Manufacturer Board No. ID Built Replacement Stamped Component Manufacturer Serial No.

N SI-9B VELAN VALVE NA NA S1012-002 1967 REPAIRED N CORPORATION

7. Description of Work OPEN FOR REPACKING CLASS 2 SAFETY INJECTION SYSTEM 3" VALVE SI-9B.
8. Tests conducted Hydrostatic F] Pneumatic F Nominal Operating Pressure r Exempt 1 Other n Pressure 2190 psi Test Temp. 551 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date:. 12/1/2001 Name of Component: SI-9B Work Order Number: 97-212982 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed 7&ifL 4c C A L ft** L4A, v, Date tekLM4AMJ 20 0_.

Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT to b }-.,,, and state that have inspected the components described in the Owner's Report during the period -I- 2r-,O9 to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning nor the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

X * .Commissions NB7741, I,N, IS, A WIS 100024

(--ýpectors Sign ure National Board, State, Province, and Endorsements Date / ,20 0 "-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl Date 12/3/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 00-003219 N490 HWY 42 Kewaunee. WI 54216-9511 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. INA Expiration Date NA
4. Identification of System 36 Class 1 REACTOR COOLANT Code Case NA
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Repaired, ASME Replaced, or Code Name of Name of Manufacturer National Other Year Replacement Stamped Serial No. Board No. ID Built Component Manufacturer REPLACED N LD-3 MASONEILAN H46695-1-2 NA RC011-002 1970 REPLACED N INTERNATIONAL
7. Description of Work DISASSEMBLE AND INSPECT CLASS 1 REACTOR COOLANT SYSTEM 2" VALVE LD-3 AND REPLACE 8 STUDS AND 8 NUTS.
8. Tests conducted Hydrostatic F] Pneumatic n Nominal Operating Pressure E' Exempt El Other F] Pressure 2240 psi Test Temp. 551 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 12/3/2001 Name of Component: LD-3 Work Order Number: 00-003219 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Date 20 0=1 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period ,1-5-O 0 to /-3-bZ, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I,N, IS, A WIS 100024 4/setors Sign6(ure National Board, State, Province, and Endorsements Date 20 1' T,

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 12/3/2001

1. Owner Wisconsin Public Service Corooration Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 00-004319 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA 05A Class 2 FEEDWATER Expiration Date NA
4. Identification of System
5. (a) Applicable Construction Code NA Code Case NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Serial No. Board No. ID Built Replacement Stamped Component Manufacturer 25.12620.004-1 NA 1S-0066 1971 REPLACEMENT N SG-AH-1 MCDOWELL WELLMAN
7. Description of Work REBUILD 900 KIP HYDRAULIC SNUBBER ON CLASS 2 MAIN STEAM AND STEAM DUMP SYSTEM STEAM GENEARTOR IA.
8. Tests conducted Hydrostatic -l Pneumatic -1D Nominal Operating Pressure D: Exempt FR psi Test Temp.

Other L] Pressure deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 12/3/2001 Name of Component: SG-AH-1 Work Order Number: 00-004319 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Date 20 0,;0 Signed & "9LAdJ&ti-L" ZM5dAA, '

Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 745r-', to /--,/I-Z , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, 1, N, IS, A WIS 100024 Inspector's S~i ature National Board, State, Province, and Endorsements Date 6A"* / 20 0,7 0

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl Date 12/3/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 00-004319 N490 HWY 42 Kewaunee. WI 54216-9511 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA Expiration Date NA
4. Identification of System 05A Class 2 FEEDWATER Code Case NA
5. (a) Applicable Construction Code NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Repaired, ASME Other Year Replaced, or Code Name of Name of Manufacturer National ID Built Replacement Stamped Serial No. Board No.

Component Manufacturer REPLACEMENT N MCDOWELL 25.12620.004-7 NA 1S-0066 1971 REPLACEMENT N SG-AH-2 WELLMAN

7. Description of Work REBUILD 900 KIP HYDRAULIC SNUBBER ON CLASS 2 MAIN STEAM AND STEAM DUMP SYSTEM STEAM GENERATOR lB.
8. Tests conducted Hydrostatic El Pneumatic El Nominal Operating Pressure -- Exempt 17 Pressure psi Test Temp. deg. F Other r--
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 12/3/2001 Name of Component: SG-AH-2 Work Order Number: 00-004319 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed , ewr-m- "* LO1 f, -, Date ,20 0 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 17 -0Oto /- J/o-02, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, 1, N, IS, A WIS 100024 Unspector's Siglature National Board, State, Province, and Endorsements Date .20 '

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation Date 2/26/2001 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 01-001998
3. Work Performed By Nuclear Management Company, LLC Type Code Sym. Stamp NA 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 35 Class 2 CHEMICAL AND VOLUME CONTROL Expiration Date NA
5. (a) Applicable Construction Code NA Code Case NA (b) Applicable Edition of Section X1 Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped APCH-11B AJAX IRON 6576 NA 00076 1967 REPAIRED N WORKS
7. Description of Work REPAIR CLASS 2 CHEMICAL AND VOLUME CONTROL SYSTEM CHARGING PUMP 1B SUCTION VALVE.
8. Tests conducted Hydrostatic E- Pneumatic 1 Nominal Operating Pressure El Exempt 1:]

Other D Pressure 26 psi Test Temp. 115 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 2/26/2001 Name of Component: APCH-1 B Work Order Number: 01-001998 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed k &*SaNdUft4U Date 200 ;6 Owner's Designee, Title Owner or Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 1-7-r-00 to 1-3/1-2 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I,N, IS, A WIS 100024 Inspector's Si ature National Board, State, Province, and Endorsements Date a20 0 ;t-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation Date 12/3/2001 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 01-002115
3. Work Performed By Nuclear Management Company, LLC Type Code Sym. Stamp NA 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 36 Class 1 REACTOR COOLANT Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case N-416-2 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped RC-W76DM PCIENERGY 110/1M NA NA 2001 REPLACED N SERVICES
7. Description of Work REPLACED WELD FOR CLASS 1 REACTOR COOLANT SYSTEM STEAM GENERATOR 1A NOZZLE TO SAFE END WELD
8. Tests conducted Hydrostatic Nominal Operating Pressure r7 Exempt 11 Pneumatic r-Other r- Pressure 2240 psi Test Temp. 551 deg. F
9. Remarks UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SECTION XI: CODE CASE N-416-2 PER NRC APPROVAL OF RELIEF REQUEST RR-G-4.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date:

  • 12/3/2001 Name of Component: RC-W76DM Work Order Number: 01-002115 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA

-0M- Date 20 0 Signed  ;% &4,0~ 7eýP 04&

Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period *1,2f-l to /- 3/1#2.., and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4 lns c7 &Commissions NB7741, I, N, IS, A WIS 100024 Inspector's Si National Board, State, Province, and Endorsements Date f I ,20 0 Z

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation Date 12/3/2001 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 01-002115 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 36 Class 1 REACTOR COOLANT Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case N-416-2 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped RC-W77DM PCI ENERGY NA NA NA 2001 REPLACED N SERVICES
7. Description of Work REPLACED WELD FOR CLASS 1 REACTOR COOLANT SYSTEM STEAM GENERATOR 1A NOZZLE TO SAFE END.
8. Tests conducted Hydrostatic El Pneumatic Nominal Operating Pressure Exempt 1 Other D Pressure 2240 psi Test Temp. 551 deg. F
9. Remarks UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SECTION XI: CODE CASE N-416-2 PER NRC APPROVAL OF RELIEF REQUEST RR-G-2.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 12/3/2001 Name of Component: RC-W77DM Work Order Number: 01-002115 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed &14" Date 4 20 oA Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-4U'-00 to /°.3 I'V2, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I,N, IS, A WIS 100024 nspector's Sigrature National Board, State, Province, and Endorsements Date

  • 20 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl Date 12/3/2001
1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-002115 N490 HWY 42 Kewaunee. WI 54216-9511 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson. Wisconsin 54016 Authorization No. NA Expiration Date NA
4. Identification of System 36 Class 1 REACTOR COOLANT Code Case N-416-2
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASM Repaired, ASME Code Other Year Replaced, or Name of Name of Manufacturer National Stamped Board No. ID Built Replacement Component Manufacturer Serial No.

REPLACED N PCIENERGY 110/2 NA NA 2001 REPLACED N RC-W78DM SERVICES

7. Description of Work REPLACED WELD FOR CLASS 1 REACTOR COOLANT SYTEM STEAM GENERATOR 1B NOZZLE TO SAFE END WELD.

Nominal Operating Pressure L Exempt

8. Tests conducted Hydrostatic Pneumatic F Test Temp. 55_1 deg. F Other D Pressure 2240 psi
9. Remarks UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SECTION XI: CODE CASE N-416-2 PER NRC APPROVAL OF RELIEF REQUEST RR-G-4.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date:. 12/3/2001 Name of Component: RC-W78DM Work Order Number: 01-002115 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed , R lOr. Date ,n 4 20 0.

Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period __-_______ to /- 31-07-, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, 1, N, IS, A WIS 100024 Inspectors ,nature National Board, State, Province, and Endorsements Date . / ,20 *-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 12/3/2001

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 01-002115 Type Code Sym. Stamp N.AA
3. Work Performed By Nuclear Manaqement Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 36 Class 1 REACTOR COOLANT Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case N-416-2 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Serial No. Board No. ID Built Replacement Stamped Component Manufacturer PCIENERGY 110/1 NA NA 2001 REPLACED N RC-W79DM SERVICES
7. Description of Work REPLACED WELD FOR CLASS 1 REACTOR COOLANT SYSTEM STEAM GENERATOR 1B NOZZLE TO SAFE END.

Exempt 1

8. Tests conducted Hydrostatic rF Pneumatic F Nominal Operating Pressure E Other D Pressure 2240 psi Test Temp. 551 deg. F
9. Remarks UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SECTION XI: CODE CASE N-416-2 PER NRC APPROVAL OF RELIEF REQUEST RR-G-4.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date:. 12/3/2001 Name of Component: RC-W79DM Work Order Number: 01-002115 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed && I1IWA W &OnL~n dUM" Date 20 01 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 72 to ,/-3/-, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, 1, N, IS, A WIS 100024 rInspector's Si ature National Board, State, Province, and Endorsements Date * ."20 D ,

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 12/11/2001

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 01-003411 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA Expiration Date NA
4. Identification of System 34 Class 2 RESIDUAL HEAT REMOVAL
5. (a) Applicable Construction Code SECTION III CLASS 2 Code Case NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped RHR-33-1 CROSBY VALVE AND GAGE N62651-00-0001 NA ACl 15-001 1978 REPAIRED N COMPANY
7. Description of Work REMOVE FOR TESTING CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM 4" VALVE RHR-33-1.
8. Tests conducted Hydrostatic EI Pneumatic 1"1 Nominal Operating Pressure El Exempt 1 Other F Pressure 150 psi Test Temp. 60 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 12/1/2001 Name of Component: RHR-33-1 Work Order Number: 01-003411 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed CA194 &V4ii Date 1-1 -20 Q Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 97I,.-v, to /-3/- 0 Z., and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

24 ,Commissions NB7741, 1,N, IS, A WIS 100024 lnspector'sSiaature National Board, State, Province, and Endorsements Date ,C / 20 0

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section X1

1. Owner Wisconsin Public Service Corporation Date 12/1/2001 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 01-003412
3. Work Performed By Nuclear Management Company, LLC Type Code Sym. Stamp N..A 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 34 Class 2 RESIDUAL HEAT REMOVAL Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped RHR-33 CROSBY ASHTON GAGE NF NA AC107-001 1971 REPAIRED N COMPANY
7. Description of Work REMOVE FOR TESTING CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM 2" VALVE RHR-33.
8. Tests conducted Hydrostatic [] Pneumatic Nominal Operating Pressure Exempt 1 Other n Pressure 150 psi Test Temp. 60 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date:. 12/1/2001 Name of Component: RHR-33 Work Order Number: 01-003412 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed . If-.A 4eI4A., L Date q 1 .

,20 O.1 Title Owner or Owner's Designee, Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period ?7-2,r-a to/- 3/-# 2- , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

SCommissions NB7741, , N, IS, A WIS 100024 Inspector's Sigjture National Board, State, Province, and Endorsements Date ,20 9'9;-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl Date 11/26/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-004985 N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA Expiration Date NA
4. Identification of System 23 Class 2 CONTAINMENT SPRAY Code Case NA
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Repaired, ASME National Other Year Replaced, or Code Name of Name of Manufacturer Board No. ID Built Replacement Stamped Component Manufacturer Serial No.

REPAIRED N Cl-1003 WILLIAM POWELL NF NA ICS022-001 1968 REPAIRED N CO.

7. Description of Work OPEN FOR INSPECTION CLASS 2 CONTAINMENT SPRAY 2" VALVE Cl-1003.

Nominal Operating Pressure M

8. Tests conducted Hydrostatic Pneumatic F] Exempt 1 Other F Pressure 31 psi Test Temp. 69.6 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: .11/26/2001 Name of Component: C1-1003 Work Order Number: 01-004985 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed . a e &.a 4..'2%, AoLv c ,.lý 4 Date 6uomi 20 Title Owner or Owner's Designee, Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period Y-Ar-a to -3dJJ-, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

&ýý-1,.,.*Commissions

"= NB7741, I, N, IS, A WIS 100024 Inspector's jgnature National Board, State, Province, and Endorsements Date / ,20

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation Date 12/3/2001 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 01-005010 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 33 Class 1 SAFETY INJECTION Expiration Date NA
5. (a) Applicable Construction Code B16.5-1967 Code Case NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped SI-21A ANCHOR/DARLING 11542-13 NA SIl15-003 1970 REPAIRED N ENTERPRISES
7. Description of Work OPEN FOR INSPECTION CLASS 1 SAFETY INJECTION SYSTEM 12" VALVE SI-21A.
8. Tests conducted Hydrostatic Pneumatic Nominal Operating Pressure Exempt 1--

Other F Pressure 2240 psi Test Temp. 551 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date:. 12/3/2001 Name of Component: SI-21A Work Order Number: 01-005010 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed ,, 'e* . -L'-*4 A 0 ,X Date 20 Q,1 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 1 ,-Knevto -,,31/'2,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

lnp ,Commissions NB7741, I,N, IS, A WIS 100024 Inspector'si ature National Board, State, Province, and Endorsements Date -- :4 ,20 Z

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation Date 12/3/2001 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 01-005011
3. Work Performed By Nuclear Management Company, LLC Type Code Sym. Stamp NA 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 33 Class 1 SAFETY INJECTION Expiration Date NA
5. (a) Applicable Construction Code B16.5-1967 Code Case NA (b) Applicable Edition of Section X1 Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped SI-21 B ANCHOR/DARLING VALVE NF NA S1115-004 1970 REPAIRED N COMPANY
7. Description of Work OPEN FOR INSPECTION CLASS 1 SAFETY INJECTION SYSTEM 12" VALVE SI-21B.
8. Tests conducted Hydrostatic F Pneumatic r-1 Nominal Operating Pressure El Exempt 1]

Other Dl Pressure 2240 psi Test Temp. a55 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 12/3/2001 Name of Component: SI-21B Work Order Number: 01-005011 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed ,4gADt I4.*, Date. 20 OZ Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period __-2___O' to 14/4O2-, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

ý_ -Commissions NB7741, 1, N, IS, A WIS 100024 National Board, State, Province, and Endorsements

_.Inspector's Signature Date / 20

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation Date 11/26/2001 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 01-005012 Type Code Sym. Stamp N._A
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA SAFETY INJECTION Expiration Date NA
4. Identification of System 33 Class 1
5. (a) Applicable Construction Code B16.5-1967 Code Case NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Serial No. Board No. ID Built Replacement Stamped Component Manufacturer NF NA S1115-001 1970 REPAIRED N SI-22A ANCHOR/DARLING ENTERPRISES
7. Description of Work OPEN FOR INSPECTION CLASS 1 SAFETY INJECTION SYSTEM 12" VALVE SI-22A.

Nominal Operating Pressure =.

8. Tests conducted Hydrostatic Pneumatic F Exempt 1"-

Other F Pressure 750 psi Test Temp. 63 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: .11/26/2001 Name of Component: SI-22A Work Order Number: 01-005012 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed *0 *..IW .A fPA"?1 LJ6 l'1, Date 20 0-1 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the pedod _'__"__ to /-3/"6-a, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

SCommissions NB7741, I, N, IS, A WIS 100024 Inspector's nature National Board, State, Province, and Endorsements Date ,20 2 9

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation Date: 12/12/01 700 North Adams P.O. Box 19001 Sheet: 1 of 3 Green Bay, WI 54307-9001
2. Plant: Kewaunee Nuclear Power Plant Unit: No.1 N490 HWY 42 Kewaunee WI 54216-9511 Work Order#: SEE BELOW WORK ORDER WP&IR DESCRIPTION 01-007152 M-FCU-385 REMOVE AND RECONNECT SW PIPING TO CFCU'S
3. Work Performed by: Bechtel Construction
4. Identification of System: 02 Class: 3 Name: SERVICE WATER
5. (a) Applicable Construction Code: USAS B31.1, 1967 Ed. , No Add. C ode Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add. C ode Case: N/A
6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code No. or Stamped Replacement Yes/No See continuation sheet, page 3

7. Description of Work: REMOVE AND REINSTALL SERVICE WATER SYSTEM CONTAINMENT COOLING CONTAINMENT FAN COIL UNITS C AND D AND ASSOCIATED SERVICE WATER LINES
8. Tests Conducted: Hydrostatic E] Pneumatic [j Nominal Operating Pressure Z Exempt E]

Other: El Pressure: 92 psi Test Temp: 44.2 0 F Page 1 of`3

Date: 12/12/01 Name of Component: SERVICE WATER Work Order Number: 01-007152 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code,Section XI repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed: Date/--Date Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period 0 -Uf to I , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward)_ _ _ _ Commissions ' I(*A4 '

Inspector's Signature National Board, State, Province, and Endorsements Date: /a-/*- 2001 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Page 2 of 3

Continuation Sheet Name of Component SERVICE WATER Work Order Number: 01-007152 Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No. Board Identification: Built Replaced Code No. Or Stamped Replacement Yes/No CFCU C INLET N/A N/A N/A N/A N/A REPAIRED NO PIPING CFCU C OUTLET N/A N/A N/A N/A N/A REPAIRED NO PIPING CFCU D INLET N/A N/A N/A N/A N/A REPAIRED NO PIPING CFCU D OUTLET N/A N/A N/A N/A N/A REPAIRED NO PIPING 5/8" BOLTS MACKSON N/A N/A HT USY87951 N/A REPLACEMENT NO 5/8" NUT MACKSON N/A N/A HT 7307732 N/A REPLACEMENT NO 5/8" STUD MACKSON N/A N/A HT M60635 N/A REPLACEMENT NO t t -t 1 1 t - I I t I* +/- I I f + I 1

+ I I 1-Page 3 of 3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI Date: 12/12/01

1. Owner: Wisconsin Public Service Corporation 700 North Adams Sheet: 1 of 5 P.O. Box 19001 Green Bay, WI 54307-9001 Kewaunee Nuclear Power Plant Unit : No.1
2. Plant:

N490 HWY 42 Kt.w*Ni*e WI 54216-9511 Work Order#: SEE BELOW WORK ORDER WP&IR DESCRIPTION 01-008137 M-ULR-311 Remove & Modify Upper Lateral

3. Work Performed by: Bechtel Construction
4. Identification of System: 05A Class: 2 Name: "A" Upper Lateral inclu'ding Spring Cans &

Snubber Code Case: N/A

5. (a) Applicable Construction Code: USAS B31.1, 1967 Ed. , No Add.

Code Case: N/A

6. (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989, No Add.
7. Identification of Components Repaired or Replaced and Replacement Components:

Name of Manufacturer National Other Year Repaired, ASME Name of Manufacturer Serial No. Board Identification Built Replaced, Code Component No. or Stamped Replacement Yes/No See continuation sheet, page 3

8. Description of Work: Repaired Upper Lateral Restraint and replacement of bolting and shims for upper lateral
9. Tests Conducted: Hydrostatic [] Pneumatic [] Nominal Operating Pressure F1 Exempt 0 Other: r] Pressure: psi Test Temp -F Page 1 of 5

Date: 12/12/01 Name of Component: UPPER LATERAL RESTRAINT SYSTEM.

Work Order Number: 01-008137 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code,Section XI repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed: Yi,c-,:4-.e ,Sv,- Date -!

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period n9-/1?2*!

to [t- ,oci , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward) Commissions t,*3 a SS*"-i)A-; *,'

PYft lnspeot6Fýs Signature/ National Board, State, Province, and Endorsements Date: r -/% 20 cý .

Page 2 of 5

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No. Board Identification: Built Replaced Code No. Or Stamped Replacement Yes/No "A" Hydraulic McDowell 25.12620.004-1 N/A IS-0066 1971 Repaired No Snubber Wellman "A" Upper Lateral N/A N/A N/A N/A N/A Repaired No Ring Girder Splice Plate, Ring Colonial Ht. No. 412H07 N/A N/A 2001 Replacement No Girder, ASTM A588, Gr. A Splice Plate Bolt, Colonial HT No. 10187- N/A N/A 2001 Replacement No ASTM A540, RYE Gr.B23, Cl. 2 Splice Plate Heavy Colonial Ht. No. 8994464 N/A N/A 2001 Replacement No Hex. Nuts, A194, Trace Code SBG Gr. 2H Splice Plate Colonial Ht. No. Y85307 N/A N/A 2001 Replacement No Washers, F436 Trace Code SBH Splice Plate Heavy Colonial Ht. No. S42483 N/A N/A 2001 Replacement No Hex Nuts, A 194, Trace Code I UV Gr. 2H Bumper Plate, A588 Colonial Ht. No. BI S6214 N/A N/A 2001 Replacement No GR A Side Bumper Colonial Ht. No. l B518 N/A N/A 2001 Replacement No Bearing Plate, A588 3" Threaded Rod, Colonial Ht. No. 8991820 N/A N/A 2001 Replacement No A540 Gr. B23, Cl. 2 V" Hex. Nut, A563 Colonial Ht. No. 34467PJ N/A N/A 2001 Replacement No Washer, F436 Colonial Ht. No. 107494 N/A N/A 2001 Replacement No Side Bumper Shim, Colonial Ht. No. EIF023- N/A N/A 2001 Replacement No A36 A12 Side Bumper Shim, Colonial Ht. No. E1GI 19- N/A N/A 2001 Replacement No A36 A16 Side Bumper Shim, Colonial Ht. No. EIG 119- N/A N/A 2001 Replacement No A36 A16 Side Bumper Shim, Colonial Ht. No. B1F669- N/A N/A 2001 Replacement No A36 C16 Side Bumper Shim, Colonial Ht. No. T2866 N/A N/A 2001 Replacement No A36 Side Bumper Shim, Colonial Ht. No. A1C202- N/A N/A 2001 Replacement No A36 B20 Side Bumper Shim, Colonial Ht. No. A1D370- N/A N/A 2001 Replacement No A36 B32 Side Bumper Shim, Colonial Ht. No. B1E825- N/A N/A 2001 Replacement No A36 B16 Side Bumper Shim, Colonial Ht. No. B11F555- N/A N/A 2001 Replacement No A36 C23 Side Bumper Shim, Colonial Ht. No. 64595 N/A N/A 2001 Replacement No A109 CI010 Side Bumper Shim, Colonial Ht. No. Y07405 N/A N/A 2001 Replacement No A109 CI010 Side Bumper Shim, Colonial Ht. No. 65747 N/A N/A 2001 Replacement No A109 CI010 Side Bumper Shim, Colonial Ht. No. M06708 N/A N/A 2001 Replacement No A109 CI010 Upper Lateral Ring Colonial Ht. No. N/A N/A 2001 Replacement No Plate, A36 A1T128'3 3/8" Threaded Rod, Colonial Ht. No. 813953 N/A N/A 2001 Replacement No A307, Gr. A Page 3 of 5

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No. Board Identification: Built Replaced Code No. Or Stamped Replacement Yes/No Heavy Hex Nuts, Colonial Ht. No. A61415 N/A N/A 2001 Replacement No A563, Gr. A Std. Washer, F436, Colonial Ht. No. B16294 N/A N/A 2001 Replacement No Type 1 Upper Lateral Ring Colonial Ht. No. A1U1599 N/A N/A 2001 Replacement No Plate Shim, A36 Upper Lateral Ring Colonial Ht. No. BIP5527 N/A N/A 2001 Replacement No Plate Shim, A36 Upper Lateral Ring Colonial Ht. No AOR0914 N/A N/A 2001 Replacement No Plate Shim, A36 Upper Lateral Ring Colonial Ht. No 7467439 N/A N/A 2001 Replacement No Plate Shim, A36 Upper Lateral Ring Colonial Ht. No 1A353 N/A N/A 2001 Replacement No Plate Shim, A36 3/8" Hex Hd. Bolt, Colonial Ht. No. 8878678 N/A N/A 2001 Replacement No A307-97 3/8" Std. Washer, Colonial Ht. No. B 16294 N/A N/A 2001 Replacement No F436 Type I Ring Girder Shim, Colonial Ht. No. 1E479 N/A N/A 2001 Replacement No A36 Ring Girder Shim, Colonial Ht. No. 1E744-A N/A N/A 2001 Replacement No A36 Ring Girder Shim, Colonial Ht. No. 2A6386- N/A N/A 2001 Replacement No A36 C Ring Girder Shim, Colonial Ht. No. 2A6593- N/A N/A 2001 Replacement No A36 C Ring Girder Shim, Colonial Ht. No. 4151614 N/A N/A 2001 Replacement No A109-CR1010 Ring Girder Shim, Colonial Ht. No. A86743 N/A N/A 2001 Replacement No A109-CRIOIO Ring Girder Shim, Colonial Ht. No. 4151614 N/A N/A 2001 Replacement No A109-CRIOIO Ring Girder Shim, Colonial Ht. No. R4747 N/A N/A 2001 Replacement No A36 Flat Bar Backing KNPP JB8913 N/A QADC 0 1-349 2001 Replacement No Strip, A36 Ring Girder Shim, Colonial Ht. No. 4125164 N/A N/A 2001 Replacement No A109-CRIOO1 Back Bumper Colonial MRR-01030 N/A N/A 2001 Replacement No Bearing Plate and Pipes 3/4" Threaded Rod, Colonial Ht. No. 8991820 N/A N/A 2001 Replacement No A540 Gr B23, C12 3/4/4" Nut, A563 Colonial 31167PJ N/A N/A 2001 Replacement No 3/4" Washer, F436 Colonial 107494 N/A N/A 2001 Replacement No Back Bumper Shim, Colonial E1F023-A12 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial EIGI 19-A16 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial B1F669-C16 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial T2866 N/A N/A 2001 Replacement No A36 I Page 4 of 5

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No. Board Identification: Built Replaced Code No. Or Stamped Replacement Yes/No Back Bumper Shim, Colonial A1C202-B20 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial A 1D370-B23 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial B1E825-B16 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial B1F555-C23 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial 64595 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial Y07405 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial 65747 N/A N/A 2001 Replacement No A36 Ring Girder Shim, Colonial Ht. No. 2A6386- N/A N/A 2001 Replacement No A36 E Ring Girder Shim, Colonial Ht. No. 2A6593- N/A N/A 2001 Replacement No A36 E Snubber Bracket Colonial Ht No C0453 N/A N/A 2001 Replacement No Shim Page 5 of 5

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation Date: 12/12/01 700 North Adams P.O. Box 19001 Sheet: 1 of 2 Green Bay, WI 54307-9001
2. Plant: Kewaunee Nuclear Power Plant Unit: No. 1 N490 HWY 42 K4.waiine. Wl 54216-9511I Work Order#: SEE BELOW Kewaunee WI 54216-9511 WORK ORDER WP&IR DESCRIPTION 01-013145 M-SGA-362 REMOVE SHIPPING COVER 01-013376 M-SDS-322 SEVER STEAM DOME 01-008136 M-SDA-370 REFURBISH STEAM DOME 01-013376 M-SDA-372 RE-INSTALL STEAM DOME
3. Work Performed by: Bechtel Construction
4. Identification of System: 05/06 Class: 2 Name: "A" Steam Generator Secondary Side
5. (a) Applicable Construction Code: USAS B31.1, 1967 Ed. , No Add. Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add. Code Case: N-416-2
6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code No. or Stamped Replacement Yes/No Steam Dome Westinghouse 1141 68-28 N/A 1970 Repaired Yes Replacement SG Ansaldo 202 151 N/A 2000 Replacement Yes Lower assembly Feedwater Nozzle PCI FW # 1 N/A MRR-01019 2001 Replacement No Adaptor Main Steam Flow Ansaldo N/A N/A QADC-01-041 2000 Replacement No Limiter

_________________ I _______________ ______________ _________ '. ________________ ..- _____ -

7. Description of Work: Prep New lower assembly for Steam Dome installation, Remove Steam Dome from the Old Lower Assembly, Refurbish the Feedwater Nozzle, Install the Main Steam Flow Limiter, Install the Steam Dome on the New Lower Assembly
8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure
  • Exempt E]

Other: E] Pressure: 1040 psi Test Temp: 549.35°F

  • NOTE: The Secondary Side Hydrotest was conducted at NOP per Code Case N-416- 2 Page 1 of2

Date: 12/12/01 Name of Component: SG # A Work Order Number: 01-013145, 01-008136, 01-013376.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code,Section XI repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed: -- '

1(uf% / Date (.

uwner or uwner s uesigjnee, I We CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the periodn'-/7Z-to I-t'p , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward) Commissions fn ý I/a.(

t * </ 'I Inspector s Signature/ National Board, State, Province, and Endorsements Date: 200\

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation Date: 12/12/01 700 North Adams P.O. Box 19001 Sheet: 1 of 4 Green Bay, WI 54307-9001
2. Plant: Kewaunee Nuclear Power Plant Unit: No.1 N490 HWY 42 Kp~w*inp.* WI 54216-9511I Work Order# : SEE BELOW Kewaunee WI 54216-9511 WORK ORDER WP&IR DESCRIPTION 01-013376 M-LLR-314 Replace Upper Col.

Adapters and Reshim Lower Lateral Restraint

3. Work Performed by: Bechtel Construction
4. Identification of System: 36 Class: 1 Name: "B" Col. Adapter Plates and Lower Lateral Shims
5. (a) Applicable Construction Code: USAS B31.1, 1967 Ed., No Add. Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add. Code Case: N/A
6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code No. or Stamped Replacement Yes/No See continuation sheet, page 3

7. Description of Work: Replaced steam generator support upper column adapters and removed and restored lower lateral support bumper guides to the steam generator and shimmed the adjacent support bumper steel.
8. Tests Conducted: Hydrostatic E] Pneumatic E Nominal Operating Pressure El Exempt 0 Other: [] Pressure: psi Test Temp Page 1 of 4

Date: 12/12/01 Name of Component: "B" Upper Col. Adapter Plates and Reshim Lower Lateral Restraint.

Work Order Number: 01-013376 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code,Section XI repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed: , KA%* . -5,, Dateý.2.//,Mw Owner or Owner's Desianec*. I Itl*

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period 05 -,/ti1 to . - , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward)__ Commissions ^'-Z3 ii c*V('i9V' c

Inspector's Signature/ National Board, State, Province, and Endorsements Date [1 1 2001 Page 2 of 4

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No. Board Identification: Built Replaced Code No. Or Stamped Replacement Yes/No Shims Colonial Ht. No. 4125164 N/A N/A 2001 Replacement No Shims Colonial Ht. No. A86743 N/A N/A 2001 Replacement No Shims Colonial Ht. No. 4151614 N/A N/A 2001 Replacement No Shims Colonial Ht. No. 2A6593- N/A N/A 2001 Replacement No A

Shims Colonial Ht. No. T 1273-A N/A N/A 2001 Replacement No Shims Colonial Ht. No. 1E802 N/A N/A 2001 Replacement No Shims Colonial Ht. No. R6759 N/A N/A 2001 Replacement No Shims Colonial Ht. No. 2A6387- N/A N/A 2001 Replacement No A

Shims Colonial Ht. No. R6791 N/A N/A 2001 Replacement No Shims Colonial Ht. No. 2A6593- N/A N/A 2001 Replacement No E

Shims Colonial Ht. No. 2A6386- N/A N/A 2001 Replacement No D

Shims Colonial Ht. No. 2A6384- N/A N/A 2001 Replacement No A

Shims Colonial Ht. No. TI273-B N/A N/A 2001 Replacement No Shims Colonial Ht. No. R4747 N/A N/A 2001 Replacement No Shims Colonial Ht. No. 1E803 N/A N/A 2001 Replacement No Shims Colonial Ht. No. R6791 N/A N/A 2001 Replacement No Shims Colonial Ht. No. 1E542 N/A N/A 2001 Replacement No 1" Bolts A325 Colonial Ht. No. 706907 N/A N/A 2001 Replacement No 1" Bolts A325 Colonial Ht. No. 213265 N/A N/A 2001 Replacement No 1" Flat Washers Colonial Ht. No. B28393 N/A N/A 2001 Replacement No F436-93 I" Hex. Hd. Nuts Colonial Ht. No. S41165 N/A N/A 2001 Replacement No A194 Gr. 2H 3/4" Bolt, A-490 Colonial Ht. No. 8996654 N/A N/A 2001 Replacement No Colonial Ht. No. 43739D N/A N/A 2001 Replacement No 3/4" Lockwashers B 18.21 S.G. Col. Adapter Colonial Fabricated N/A MRR 01042 2001 Replacement No A588 Assembly Page 3 of 4

Manufacturer National Other Year Repaired ASME Name of Name of Serial No. Board Identification: Built Replaced Code Component Manufacturer No. Or Stamped Replacement Yes/No Colonial Ht. No. N/A N/A 2001 Replacement No S.G. Col. Adapter Pin AISI 4340 8996496C0477 2 0 R pa e n N S.G. Col. Adapter Colonial Ht. No. N/A N/A 2001 Replacement No Pin Washer A-588, 803M62250 Gr. A S.G. Col. Adapter Colonial Ht. No. 255029 N/A N/A 2001 Replacement No Pin Washer Bolts Trace Code IUX A-325 S.G. Adapter Col. Colonial Ht. No. 10618 N/A N/A 2001 Replacement No Adapter Bolts A- Trace No. IUU 54 0, Gr. B 23 , Cl. 2 2001_R place entN S.G. Adapter Col. Colonial Ht. No. S42483, N/A N/A 2001 Replacement No Jam Nuts, SA307 Trace No. IUY Gr. B Colonial Ht. No. 8994464 N/A N/A 2001 Replacement No S.G. Adapter Col.

Heavy Hex. Nut, Ht Code SBG SA 194 Gr. 2H Colonial Ht. No. 8997945 N/A N/A 2001 Replacement No S.G. Col. Adapter Washers AISI 4150 Trace Code I UW I-- I I. I* -I- I 1

_______ I + I I 1

_______ I F + I I 1

_________ F F I I I 1

_______ I F I I I t

_ _ _ _ _ I I I I I 1I -

Page 4 of 4

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation Date: 12/13/01 700 North Adams P.O. Box 19001 Sheet: 1 of 2 Green Bay, WI 54307-9001
2. Plant: Kewaunee Nuclear Power Plant Unit: No. 1 N490 HWY 42 Kewaunee, WI 54216-9511 Work Order#: SEE BELOW WORK ORDER WP&IR DESCRIPTION 01-008135 M-BDA-382 S.G. "A"BLOWDOWN CUT / REWELD 01-008135 M-BDB-383 S.G. "B"BLOWDOWN CUT / REWELD 01-013145 M-SGA-364 S.G. "A" SMALL BORENOZZLE PREPS 01-013145 M-SGB-365 S.G. "B"SMALL BORE NOZZLE PREPS
3. Work Performed by: Bechtel Construction
4. Identification of System: 07 Class: 2 Name: BLOWDOWN
5. (a) Applicable Construction Code: USAS B31.1, 1967 Ed. , No Add. Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add. Code Case: N-416-2
6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code No. or Stamped Replacement Yes/No SG LOOP-A N/A N/A N/A N/A N/A Repaired No BLOWDOWN PIPING SG LOOP-A ANSALDO 202 151 N/A 2000 Replacement Yes LOWER ASSY BLOWDOWN NOZZLE SG LOOP-B N/A N/A N/A N/A N/A Repaired No BLOWDOWN PIPING SG LOOP-B ANSALDO 201 150 N/A 2000 Replacement Yes LOWER ASSY BLOWDOWN NOZZLE

7. Description of Work: TEMPORARY REMOVAL OF EXISTING BLOWDOWN PIPING AT EACH STEAM GENERATOR OUTLET NOZZLE AND PREPERATION OF BLOWDOWN NOZZLES ON NEW STEAM GENERATOR LOWER ASSEMBLIES. ALL PIPING WAS PREPARED AND REINSTALLED BY WELDING.
8. Tests Conducted: Hydrostatic F] Pneumatic E] Nominal Operating Pressure [* Exempt rl Other: [] Pressure: A-1040 psi / B-1030 psi Test Temp: A-549.35°F / B-548.17°F
  • NOTE: The Secondary Side Hydrotest was conducted at NOP per Code Case N-416- 2 Page 1 of2

Date: 12/13/01 Name of Component: BLOWDOWN Work Order Number: 01-008135 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code,Section XI repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed:

  • 4* Ak*qJftR SA-,cz5'"- Date I/j*a/KL Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period 65 -I>"-*

to 1 tI ' \ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward) Commissions r,3 ii S-) A,.Qi L-'- /( Y 9 Inspect& 'SIgf' ture National Board, State, Province, and Endorsements Date: ___ _ .2001 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI Date: 12/13/01

1. Owner: Wisconsin Public Service Corporation 700 North Adams Sheet: 1 of 5 P.O. Box 19001 Green Bay, WI 54307-9001
2. Plant: Kewaunee Nuclear Power Plant Unit: No. 1 N490 HWY 42 IKowai~n*. WI 54216-9511 Work Order#: SEE BELOW Kewaunee WI 54216-9511 WORK ORDER WP&IR DESCRIPTION 01-008137 M-ULR-312 Remove & Modify Upper Lateral
3. Work Performed by: Bechtel Construction
4. Identification of System: 5A Class: 2 Name: "B" Upper Lateral inclu ding Spring Cans &

Snubber Code Case: N/A

5. (a) Applicable Construction Code: USAS B31.1, 1967 Ed., No Add.

Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add.

6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year Repaired, ASM:

Component Manufacturer Serial No. Board Identification Built Replaced, Code No. or Stamped Replacement Yes/No See continuation sheet, page 3 1 4- -k I F I 4- 4- 4 1 F I 4- I I F I

__________ .1._________ L________ A______ i __________ L ___ J

7. Description of Work: Repaired Upper Lateral Restraint and replacement of bolting and shims for upper lateral
8. Tests Conducted: Hydrostatic E] Pneumatic E] Nominal Operating Pressure n Exempt Z Other: n Pressure: psi Test Temp oF.

Page 1 of 5

Date: 12/13/01 Name of Component: UPPER LATERAL RESTRAINT SYSTEM.

Work Order Number: 01-008137 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code,Section XI repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed: 2L4 ý KL-pPpmq;ýSý Date / i/ol "Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period C9-/'f2"rl to - K-'0"* , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected wi this inspection.

(Robert T. Ward) Commissions p /i-*?ApJ/? L-j *"/i('$'

Inspec sSignature/ National Board, State, Province, and Endorsements Date: 2001 Page 2 of 5

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet paired ASME Nai me of Manufacturer National Other Year Re placed Code Name of Built Re Ma nufacturer Serial No. Board Identification: Stamped Component Or placement No. Yes/No Re paired No N/A N/A N/A N/A N/A Re "B" Hydraulic Snubber paired No N/Ak N/A N/A N/A N/A Re "B" Upper Lateral Ring Girder placement No Col onial Ht. No. 412H07 N/A N/A 2001 Re Splice Plate, Ring Girder, ASTM A588, Gr. A Splice Plate Bolt, ASTM A540, Gr.B23, Cl. 2 Splice Plate Heavy Colonial Colonial HT No. 10187 RYE Ht. No. 8994464 N/A N/A N/A N/A 2001 2001 Re Re placement Replacement F

No No Trace Code SBG Hex. Nuts, A194, Gr. 2H 2001 Replacement No Ht. No. Y85307 N/A N/A Splice Plate Colonial Trace Code SBH Replacement No Washers, F436 N/A N/A 2001 Colonial Ht. No. S42483 Splice Plate Heavy Hex Nuts, A 194, Trace Code I UV Gr. 2H 2001 Replacement No Colonial Ht. No. BIS6214 N/A N/A No Bumper Plate, A588 2001 Replacement Ht. No. 1B518 N/A N/A Side Bumper Colonial Bearing Plate, A588 2001 Replacement No Ht. No. 8991820 N/A N/A 3/4" Threaded Rod, Colonial A540 Gr. B23, Cl. 2 2001 Replacement No Ht. No. 34467PJ N/A N/A 3/4" Hex. Nut, A563 Colonial 2001 Replacement No Ht. No. 107494 N/A N/A Washer, F436 Colonial 2001 Replacement No Ht. No. EIF023 N/A N/A Side Bumper Shim, Colonial A12 Replacement No A36 N/A 2001 Colonial Ht. No. E1GI19 N/A Side Bumper Shim, A16 Replacement No A36 N/A N/A 2001 Colonial Ht. No. EIG119 Side Bumper Shim, A16 Replacement No A36 N/A 2001 Colonial Ht. No. B1F669 N/A Side Bumper Shim, C16 Replacement No A36 N/A N/A 2001 Colonial Ht. No. T2866 Side Bumper Shim, A36 2001 Replacement No Ht. No. Al C202 N/A N/A Side Bumper Shim, Colonial B20 2001 Replacement No A36 N/A N/A Colonial Ht. No. A1D370 Side Bumper Shim, B32 Replacement No A36 N/A N/A 2001 Colonial Ht. No. BIE825 Side Bumper Shim, B16 Replacement No A36 N/A N/A 2001 Colonial Ht. No. BIF555 Side Bumper Shim, C23 Replacement No A36 N/A 2001 Colonial Ht. No. 64595 N/A Side Bumper Shim, A109 CIO10 2001 Replacement No Ht. No. Y07405 N/A N/A Side Bumper Shim, Colonial A109 C1010 2001 Replacement No Ht. No. 65747 N/A N/A Side Bumper Shim, Colonial A109 CI010 2001 Replacement No Ht. No. M06708 N/A N/A Side Bumper Shim, Colonial A109 CI010 2001 Replacement No Colonial Ht. No. 404875 N/A N/A Washer Plate, A36 2001 Replacement No Colonial Ht. No. A1T1203 N/A N/A Upper Lateral Ring Plate, A36 Page 3 of 5

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No. Board Identification: Built Replaced Code No. Or Stamped Replacement Yes/No 3/8" Threaded Rod, Colonial Ht. No. 813953 N/A N/A 2001 Replacement No A307, Gr. A Heavy Hex Nuts, Colonial Ht. No. A61415 N/A N/A 2001 Replacement No A563, Gr. A Std. Washer, F436, Colonial Ht. No. B 16294 N/A N/A 2001 Replacement No Type I Upper Lateral Ring Colonial Ht. No. AIU1599 N/A N/A 2001 Replacement No Plate Shim, A36 Upper Lateral Ring Colonial Ht. No. BIP5527 N/A N/A 2001 Replacement No Plate Shim, A36 3/8" Hex Hd. Bolt, Colonial Ht. No. 8878678 N/A N/A 2001 Replacement No A307-97 3/8" Std. Washer, Colonial Ht. No. B16294 N/A N/A 2001 Replacement No F436 Type I Ring Girder Shim, Colonial Ht. No. 1E479 N/A N/A 2001 Replacement No A36 Ring Girder Shim, Colonial Ht. No. 1E744 N/A N/A 2001 Replacement No A36 Ring Girder Shim, Colonial Ht. No. 2A6386- N/A N/A 2001 Replacement No A36 C Ring Girder Shim, Colonial Ht. No. 2A6593- N/A N/A 2001 Replacement No A36 C Ring Girder Shim, Colonial Ht. No. 4151614 N/A N/A 2001 Replacement No A109-CRI010 Ring Girder Shim, Colonial Ht. No. A86743 N/A N/A 2001 Replacement No A109-CRIOIO Ring Girder Shim, Colonial Ht. No. R4747 N/A N/A 2001 Replacement No A36 Flat Bar Backing KNPP JB8913 N/A QADC 01-349 2001 Replacement No Strip, A36 Ring Girder Shim, Colonial Ht. No. 4125164 N/A N/A 2001 Replacement No A109-CRIOIO Back Bumper Colonial MRR-01030 N/A N/A 2001 Replacement No Bearing Plate and Pipes 3/4" Threaded Rod, Colonial Ht. No. 8991820 N/A N/A 2001 Replacement No A540 Gr B23, C12 3/4" Nut, A563 Colonial 31167PJ N/A N/A 2001 Replacement No 3/4" Washer, F436 Colonial 107494 N/A N/A 2001 Replacement No Back Bumper Shim, Colonial E1F023-A12 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial EIGI 19-A16 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial BIF669-C16 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial T2866 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial A1C202-B20 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial A1D370-B23 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial B1E825-B16 N/A N/A 2001 Replacement No A36 Page 4 of 5

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Name of Name of Manufacturer National Other Year Repaired ASME Manufacturer Serial No. Board Identification: Built Replaced Code Component No. Or Stamped Replacement Yes/No Back Bumper Shim, Colonial BIF555-C23 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial 64595 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial Y07405 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial 65747 N/A N/A 2001 Replacement No A36 Ring Girder Shim, Colonial Ht. No. 2A6386- N/A N/A 2001 Replacement No A36 E Ring Girder Shim, Colonial Ht. No. 2A6593- N/A N/A 2001 Replacement No A36 E 3/4" Nut, A563-93 Colonial 107494 N/A N/A 2001 Replacement No TYPE 1 1 1 Page 5 of 5

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation Date: 12/12/01 700 North Adams Sheet: 1 of 2 P.O. Box 19001 Green Bay, WI 54307-9001 Unit: No.1
2. Plant: Kewaunee Nuclear Power Plant N490 HWY 42 Work Order#: SEE BELOW Kewaunee WI 54216-9511 WORK ORDER WP&IR DESCRIPTION 01-013145 M-SGB-363 REMOVE SHIPPING COVER 01-013376 01-008136 M-SDS-323 SEVER STEAM DOME M-SDB-371 REFURBISH STEAM DOME 01-013376 M-SDB-373 RE-INSTALL STEAM DOME
3. Work Performed by: Bechtel Construction
4. Identification of System: 05/06 Class: 2 Name: "B" Steam Generator Secondary Side Code Case: N/A
5. (a) Applicable Construction Code: USAS B31.1, 1967 Ed. , No Add.

Code Case: N-416-2 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add.

6. Identification of Components Repaired or Replaced and Replacement Components:

Year Repaired, ASME Name of Name of Manufacturer National Other Replaced, Code Component Manufacturer Serial No. Board Identification Built or Stamped No. Replacement Yes/No Repaired Yes Steam Dome Westinghouse 1142 68-29 N/A 1970 Yes It Replacement SG Ansaldo 201 150 N/A 2000 Replacemen Lower assembly No PCI FW# 2 N/A MRR-01019 2001 Replacemen t Feedwater Nozzle

,,,,l. I.. . No Adaptor

/-UUU Main Steam Flow Ansaldo N/A N/A QAUL;-U - 1 Rep ace,./ ,L!31 t nI Limiter

7. Description of Work: Prep New lower assembly for Steam Dome installation, Remove Steam Dome from the Limiter, Install the Steam Old Lower Assembly, Refurbish the Feedwater Nozzle, Install the Main Steam Flow uome Dome on the Niew Lower seby Nominal Operating Pressure Z* Exempt [1
8. Tests Conducted: Hydrostatic E] Pneumatic El Other: M] Pressure: 1030 psi Test Temp 548.17 OF
  • NOTE: The Secondary Side Hydrotest was conducted at NOP per Code Case N-416- 2 Page 1 of 2

Date: 12/12/01 Name of Component: SG # B Work Order Number: 01-013145, 01-013376, 01-008136.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code,Section XI repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed: 4--Jp- -. Qate___________

D Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period (tc-)L/"-0 to "I

-' - I , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XA By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward) Commissions &;& (/S5"5) tJ5F Q qiLc 4' Inspector ifgnature/ National Board, State, Province, and Endorsements Date: I~-I*200\

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation Date: 12/13/01 700 North Adams Sheet: 1 of 3 P.O. Box 19001 Green Bay, WI 54307-9001
2. Plant: Kewaunee Nuclear Power Plant Unit: No.1 N490 HWY 42 Kewaunee, WI 54216-9511 Work Order#: SEE BELOW WORK ORDER WP&IR DESCRIPTION 01-008139 M-FWA-380 S.G. "A" FW /AFW CUT OUT AND WELD 01-008139 M-FWB-381 S.G. "B"FW /AFW CUT OUT AND WELD
3. Work Performed by: Bechtel Construction
4. Identification of System: 05A/05B Class: 2 Name: FEEDWATER / AFW
5. (a) Applicable Construction Code: USAS B31.1, 1967 Ed. , No Add. Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add. Code Case: N-416-2
6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code No. or Stamped Replacement Yes/No SEE CONTINUATION, SHEET 3

7. Description of Work: TEMPORARY REMOVAL OF EXISTING FEEDWATER PIPING AT EACH STEAM GENERATOR OUTLET NOZZLE. TEMPORARY REMOVAL OF EXISTING AUXILLARY FEEDWATER PIPING AT THE MAIN FEEDWATER BRANCH AT EACH STEAM GENERATOR. WELD REPAIRS ON BOTH REMOVED FEEDWATER SPOOLS AND REPLACEMENT OF FEEDWATER VENT VALVE ASSEMBLY (FW-80 A / B) CONNECTIONS USING NEW SOCKOLET AND INSERT REDUCER FITTINGS. ALL PIPING WAS PREPARED AND REINSTALLED BY WELDING
8. Tests Conducted: Hydrostatic Fl Pneumatic El Nominal Operating Pressure [* Exempt E]

Other: F] Pressure: [A-FW 1040 psi / AFW 1040 psi] [ B-FW 1030 psi / AFW 1030 psi]

0 Test Temp: [A-FW 549.351F / AFW 57 F] [B-FW 548.17'F / AFW 57°F]

  • NOTE: The Secondary Side Hydrotest was conducted at NOP per Code Case N-416- 2 Page 1 of 3

Date: 12/13/01 Name of Component: FEEDWATER / AUXILLARY FEEDWATER Work Order Number: 01-008139 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code,Section XI repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed: o4L',- AP4UP-*P ate/41sl(

DS'

/

or flun,r' ninnA Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period 09-f!)-f I to I (- ?P-C, , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward)

  • Commissions A tV ) A1- A.'

.-  ? c/-1/'

Inspector's Signature National Board, State, Province, and Endorsements Date: t 0) -r 20O0 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Page 2 of 3

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No. Board Identification: Built Replaced Code No. Or Stamped Replacement Yes/No SG LOOP-A N/A N/A N/A N/A N/A REPAIRED YES FEEDWATER SG LOOP-A N/A N/A N/A N/A N/A REPAIRED YES AUXILLARY FEEDWATER SG LOOP-B N/A N/A N/A N/A N/A REPAIRED YES FEEDWATER SG LOOP-B N/A N/A N/A N/A N/A REPAIRED YES AUXILLARY FEEDWATER SOCKOLET N/A N/A N/A HT# 2016 ANB REPLACEMENT NO 16"X 2" QADC 01-408 REDUCING N/A N/A N/A HT# 1566 ANB REPLACEMENT NO INSERT 2" X 1" QADC 01-408 Page 3 of 3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation Date: 12/12/01 700 North Adams Sheet: 1 of 2 P.O. Box 19001 Green Bay, WI 54307-9001
2. Plant: Kewaunee Nuclear Power Plant Unit: No.1 N490 HWY 42 Work Order#: SEE BELOW Kewaunee WI 54216-9511 WORK ORDER WP&IR DESCRIPTION 01-005474 M-IWR-394 S.G. "A"INSTALL LEVEL INSTR. WIDE RANGE 01-005474 M-IWR-395 S.G. "B"INSTALL LEVEL INSTR. WIDE RANGE
3. Work Performed by: Bechtel Construction
4. Identification of System: 06 Class: 2 Name: MAIN STEAM AND STEAM DUMP
5. (a) Applicable Construction Code: USAS B31.1. 1967 Ed. , No Add. Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add. Code Case: N-416-2
6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Manufacturer National Other Year Repaired, ASME Name of Component Manufacturer Serial No. Board Identification Built Replaced, Code No. or Stamped Replacement Yes/No CONDENSATE KNPP N/A N/A QADC 01-393 2001 REPLACEMENT NO POT HT 85188

7. Description of Work: INSTALL NEW UPPER WIDE RANGE TAP, CONDENSATE POT AND TUBING.
8. Tests Conducted: Hydrostatic Dl Pneumatic [I Nominal Operating Pressure Z* Exempt E]

Other: E] Pressure: A-1 040 psi / B-1 030 psi Test Temp: A-549.35°F / B-548.17°F

  • NOTE: The Secondary Side Hydrotest was conducted at NOP per Code Case N-416- 2 Page 1 of 2

Date: 12/12/01 Name of Component: MAIN STEAM AND STEAM DUMP Work Order Number: 01-005474 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code,Section XI repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed: *

  • k-,

-/%*,"' 1F*,L TIA Date Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION of Boiler Pressure Vessel Inspectors I, the undersigned, holding a valid commission issued by the National Board Boiler Inspection and Ins. Co. of and the State or Providence of Wisconsin and employed by Hartford Steam during the period OC -31 Hartford, CT have inspected the components described in this Owner's Report to I I 3-ý 1** , and state that to the best of my knowledge and belief, the Owner has performed in accordance with the examinations and taken corrective measures described in this Owner's Report requirements of the ASME Code,Section XI any warranty, expressed or By signing this certificate neither the Inspector nor his employer makes this Owner's Report. Furthermore, implied, concerning the examinations and corrective measures described in personal injury or property damage or neither the Inspector nor his employer shall be liable in any manner for any of loss of any kind arising from or connected with this inspection.

(Robert T. Ward) Commissions 0J1% 1 55") A4 UL o) 4/..y Inspector's Signature National Board, State, Province, and Endorsements Date: t* 20-X).

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation Date: 12/12/01 700 North Adams P.O. Box 19001 Sheet: 1 of 2 Green Bay, WI 54307-9001
2. Plant: Kewaunee Nuclear Power Plant Unit: No.1 N490 HWY 42 Kewaunee Wl 54216-9511 Work Order#: SEE BELOW WORK ORDER WP&IR DESCRIPTION 01-008141 M-MSA-350 S.G. "A"MS CUT OUT AND WELD 01-008141 M-MSB-351 S.G. "B"MS CUT OUT AND WELD
3. Work Performed by: Bechtel Construction
4. Identification of System: 06 Class: 2 Name: MAIN STEAM
5. (a) Applicable Construction Code: USAS B31.1, 1967 Ed. ,No Add. Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add. Code Case: N-416-2
6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code No. or Stamped Replacement Yes/No SG LOOP-A N/A N/A N/A N/A N/A REPAIRED YES MAIN STEAM SG LOOP-B N/A N/A N/A N/A N/A REPAIRED YES MAIN STEAM 1 "GAMMA PORT COLONIAL HT # 87261 N/A N/A 2000 REPLACEMENT NO PLUG X 1" LG MACHINE HT CODE A696 GR C COMPANY, INC. AEM 1 "GAMMA PORT WFI HT # 8998228 N/A N/A 2001 REPLACEMENT NO PLUG X 2" LG INTERNATIONAL HT CODE A696 GR C 297YNB

7. Description of Work: TEMPORARY REMOVAL OF EXISTING MAIN STEAM PIPING AT EACH STEAM GENERATOR OUTLET NOZZLE. EXISTING PIPING WAS PREPARED AND REINSTALLED BY WELDING.

REINSTALLATION INCLUDES ADDITION OF TWO NEW RADIOGRAPHY GAMMA PORTS AND PLUGS PER LOOP.

8. Tests Conducted: Hydrostatic E] Pneumatic E] Nominal Operating Pressure
  • Exempt E]

Other: 0 Pressure: A-1 040 psi/ B-1 030 psi Test Temp: A-549.35°F / B-548.17°F

  • NOTE: The Secondary Side Hydrotest was conducted at NOP per Code Case N-416- 2 Page 1 of`2

Date: 12/12/01 Name of Component: MAIN STEAM Work Order Number: 01-008141 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code, Section X1 repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed: 7,,"* -- , " .Date "

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION Vessel Inspectors I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure and Ins. Co. of and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection Hartford, CT have inspected the components described in this Owner's Report during the period p9-/?-oj

, and state that to the best of my knowledge and belief, the Owner has performed to /I- ?-,-

with the examinations and taken corrective measures described in this Owner's Report in accordance requirements of the ASME Code,Section XI or By signing this certificate neither the Inspector nor his employer makes any warranty, expressed Report. Furthermore, implied, concerning the examinations and corrective measures described in this Owner's property damage or neither the Inspector nor his employer shall be liable in any manner for any personal injury or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward) CommissionstX3_ii&ý) A,,.; cT Y6/,

Inspec s Signature National Board, State, Province, and Endorsements Date: h."1'* 20kO _

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI Date: 12/12/01

1. Owner: Wisconsin Public Service Corporation 700 North Adams Sheet: 1 of 2 P.O. Box 19001 Green Bay, WI 54307-9001 Unit: No.1
2. Plant: Kewaunee Nuclear Power Plant N490 HWY 42 Work Order#: SEE BELOW Kewaunee WI 54216-9511 WORK ORDER WP&IR DESCRIPTION 01-008137 M-RCS-366 S.G. "A" RCS CUT OUT AND WELD 01-008133 M-RCS-360 S.G. "A" RCS NOZZLE PREP
3. Work Performed by: Bechtel Construction
4. Identification of System: 36 Class: 1 Name: REACTOR COOLANT Code Case: N/A
5. (a) Applicable Construction Code: USAS B31.1, 1967 Ed. ,No Add.

No Add. Code Case: N-416-2 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, Components:

6. Identification of Components Repaired or Replaced and Replacement National Other Year Repaired, ASME Name of Name of Manufacturer Board Identification Built Replaced, Code Component Manufacturer Serial No.

No. or Stamped Replacement Yes/No 1141 68-28 NONE 1970 REPAIRED YES STEAM WESTINGHOUSE GENERATOR 151 QADC-00-376 2000 REPLACEMENT YES STEAM ANSALDO 202 GENERATOR REPLACEMENT NO N/A N/A HT# 8000913, N/A 11/2" CAP WESTINGHOUSE SCREW HT CODE RVP N/A N/A HT 204394, N/A REPLACEMENT NO 1 1/2" CAP WESTINGHOUSE SCREW HT CODE SAZ ASSEMBLY WAS SEVERED FROM

7. Description of Work: THE EXISTING WESTINGHOUSE LOWER INSTALLED. AND REACTOR COOLANT PIPING. A NEW LOWER ASSEMBLY WAS PREPARED.

CONNECTED TO THE REACTOR COOLANT PIPING BY WELDING.

Hydrostatic E] Pneumatic El Nominal Operating Pressure

  • Exempt El
8. Tests Conducted:

Other: El Pressure: 2240 psi Test Temp: 551 .1OF N-416- 2

  • NOTE: The Primary Side Hydrotest was conducted at NOP per Code Case Page 1 of 2

Date: 12/12/01 Name of Component: REACTOR COOLANT Work Order Number: 01-008137, 01-008133 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code,Section XI repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed: .4--- 1 .. K "£ 4fA ac- -I*>v Date /I/'cf f

Owner or Owner's DesiQnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period 09-//9 to ___- ____, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward) Commissions U*.- 3S.)3115S'7,JJ.

2(&'1 InspecteA -Signature National Board, State, Province, and Endorsements Date: to-r% 2001 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI Date: 12/12/01

1. Owner: Wisconsin Public Service Corporation 700 North Adams Sheet: 1 of 2 P.O. Box 19001 Green Bay, WI 54307-9001 Unit: No.1
2. Plant: Kewaunee Nuclear Power Plant N490 HWY 42 Work Order#: SEE BELOW Kewaunee WI 54216-9511 WORK ORDER WP&IR DESCRIPTION 01-008137 M-RCS-367 S.G. "B"RCS CUT OUT AND WELD 01-008133 M-RCS-361 S.G. "B"RCS NOZZLE PREP
3. Work Performed by: Bechtel Construction Class: 1 Name: REACTOR COOLANT
4. Identification of System: 36

-d. ,No Add. Code Case: N/A

5. (a) Applicable Construction Code: USAS B31.1, 1967 E Replacements: 1989, No Add. Code Case: N-416-2 (b) Applicable Edition of Section X1 Utilized for Repairs or and Replacement Components:
6. Identification of Components Repaired or Replaced Other Year Repaired, ASMIE Name of Name of Manufacturer PJational Identification Built Replaced, Code Component Manufacturer Serial No. EBoard 0o. or Stamped Replacement Yes/No NONE 1970 REPAIRED YES STEAM WESTINGHOUSE 1142 68-29 GENERATOR 2000 YES 201 150 QADC 00376 REPLACEMENT STEAM ANSALDO GENERATOR HT# 8000913, N/A REPLACEMENT NO 11/2" CAP WESTINGHOUSE N/A hN/A HT CODE RVP SCREW VA HT 204394, N/A REPLACEMENT NO 11/2' CAP WESTINGHOUSE N/A HT CODE SAZ SCREW FROM
7. Description of Work: THE EXISTING WESTINGHOUSE LOWER ASSEMBLY WAS SEVERED INSTALLED, AND REACTOR COOLANT PIPING. A NEW LOWER ASSEMBLY WAS PREPARED, CONNECTED TO THE REACTOR COOLANT PIPING BY WELDING.
8. Tests Conducted: Hydrostatic E] Pneumatic E] Nominal Operating Pressure [ Exempt El Other: E] Pressure: 2240 psi Test Temp: 551 .1F 2
  • NOTE: The Primary Side Hydrotest was conducted at NOP per Code Case N-416-Page 1 of 2

Date: 12/12/01 Name of Component: REACTOR COOLANT Work Order Number: 01-008137, 01-008133 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code, Section Xl repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Date 1!ý/ /

Signed: A

/4t-/ P4.r &- '_ 7 Owner or Owner's Designee, I tle CERTIFICATE OF INSERVICE INSPECTION Inspectors I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Ins. Co. of and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and I

Hartford, CT have inspected the components described in this Owner's Report during the period 05/ to P , and state that to the best of my knowledge and belief, the Owner has performed with the examinations and taken corrective measures described in this Owner's Report in accordance requirements of the ASME Code,Section XI or By signing this certificate neither the Inspector nor his employer makes any warranty, expressed Furthermore, implied, concerning the examinations and corrective measures described in this Owner's Report.

damage or neither the Inspector nor his employer shall be liable in any manner for any personal injury or property of loss of any kind arising from or connected with this inspection.

(Robert T. Ward) Commissions AA Ill'S'2dIJ; G"-s P'V(- Y..iA Ins p(ýsSig nature National Board, State, Province, and Endorsements Date: 200(

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation Date: 12/12/01 700 North Adams P.O. Box 19001 Sheet: 1of 4 Green Bay, WI 54307-9001
2. Plant: Kewaunee Nuclear Power Plant Unit: No.1 N490 HWY 42 Kewaunee WI 54216-9511 Work Order# : SEE BELOW WORK ORDER WP&IR DESCRIPTION 01-013376 M-LLR-313 Replace Upper Col.

Adapters and Reshim Lower Lateral Restraint

3. Work Performed by: Bechtel Construction
4. Identification of System: 36 Class: 1 Name: "A" Col. Adapter Plates and Lower Lateral Shims
5. (a) Applicable Construction Code: USAS B31.1, 1967 Ed. ,No Add. Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add. Code Case: N/A
6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year Repaired, ASME Component Manufacturer Serial No. Board Identification Built Replaced, Code No. or Stamped Replacement Yes/No See continuation sheet, page 3

7. Description of Work: Replaced steam generator support upper column adapters and removed and restored lower lateral suDport bumper guides to the steam generator and shimmed the adiacent support bumper steel.

Hydrostatic [] Pneumatic E] Nominal Operating Pressure El Exempt Z

8. Tests Conducted:

Other: [] Pressure: psi Test Temp OF Page 1 of 4

Date: 12/12/01 Name of Component: "A" Upper Col. Adapter Plates and Reshim Lower Lateral Restraint.

Work Order Number: 01-0133760 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code, Section Xl repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed: . - ,, eH $--V Date I 4 ,

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period C')C -/ ) -0i1 to I and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward) Commissions 6 ii -),,4 Inspecti_'s-gfiature National Board, State, Province, and Endorsements Date: - Is 2001 Page 2 of 4

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet National Other Year Repaired ASME Name of Name of Manufacturer Built Replaced Code Board Identification. Stamped Component Manufacturer Serial No. Or No. Yes/No Replacement 2001 Replacement No N/A N/A Shims Colonial Ht. No. 264344 2001 Replacement No N/A N/A Shims Colonial Ht. No. 812J3592 2001 Replacement No N/A N/A Shims Colonial Ht. No. 4126617 2001 Replacement No N/A N/A Shims Colonial Ht. No. 4122060 2001 Replacement No N/A N/A Shims Colonial Ht. No. 4155918 2001 Replacement No N/A N/A Shims Colonial Ht. No. 4125164 2001 Replacement No N/A N/A Shims Colonial Ht. No. A86743 2001 Replacement No N/A N/A Shims Colonial Ht. No. 4151614 2001 Replacement No N/A N/A Shims Colonial Ht. No. 2A6593 A 2001 Replacement No N/A N/A Shims Colonial Ht. No. T1273-A 2001 Replacement No N/A N/A Shims Colonial Ht. No. I E802 2001 Replacement No N/A N/A Shims Colonial Ht. No. R6759 2001 Replacement No N/A N/A Shims Colonial Ht. No. R6791 2001 Replacement No N/A N/A Shims Colonial Ht. No. I E542 2001 Replacement No N/A N/A V"Bolts A325 Colonial Ht. No. 706907 2001 Replacement No N/A N/A I" Bolts A325 Colonial Ht. No. 213265 2001 Replacement No N/A N/A 1" Flat Washers Colonial Ht. No. B28393 F436-93 2001 Replacement No N/A N/A I" Hex. Hd. Nuts Colonial Ht. No. S41165 A194 Gr. 2H 2001 Replacement No N/A N/A 3/4" Lockwashers Colonial Ht. No. 43739D B18.21 2001 Replacement No N/A MRR 1042 S.G. Col. Adapter Colonial Fabricated A588 Assembly 2001 Replacement No N/A N/A S.G. Col. Adapter Colonial Ht. No.

Pin AISI 4340 8996496C0477 2001 Replacement No N/A N/A S.G. Col. Adapter Colonial Ht. No.

Pin Washer A-588, 803M62250 Gr. A No Colonial Ht. No. 255029 N/A N/A 2001 I Replacement S.G. Col. Adapter Pin Washer Bolts Trace Code I UX A-325 Page 3 of 4

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No. Board Identification: Built Replaced Code No. Or Stamped Replacement Yes/No S.G. Adapter Col. Colonial Ht. No. 10618 N/A N/A 2001 Replacement No Adapter Bolts A- Trace No. IUU 540, Gr. B23, Cl. 2 S.G. Adapter Col. Colonial Ht. No. S42483, N/A N/A 2001 Replacement No Jam Nuts, SA307 Trace No. 1UY Gr. B S.G. Adapter Col. Colonial Ht. No. 8994464 N/A N/A 2001 Replacement No Heavy Hex. Nut, Ht Code SBG SA 194 Gr. 2H S.G. Col. Adapter Colonial Ht. No. 8997945 N/A N/A 2001 Replacement No Washers AISI 4150 Trace Code 1UW

%" Hex Head Bolt, Colonial 8996654 N/A N/A 2001 Replacement No A-490

___________ I 4 4 + +

4 4 +/- t t 4 4 +/- +/- t 4 4 + I t

+ *1 1 T I I [ 1 1 F Page 4 of 4

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl Date 11/26/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-005013 N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA Expiration Date NA
4. Identification of System 33 Class 1 SAFETY INJECTION Code Case NA
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Manufacturer National Other Year Replaced, or Code Name of Name of Board No. ID Built Replacement Stamped Component Manufacturer Serial No.

SI-22B ANCHOR/DARLING VALVE NF NA S1115-002 1970 REPLACEMENT N COMPANY

7. Description of Work OPEN FOR INSPECTION CLASS 1 SAFETY INJECTION SYSTEM 12" VALVE SI-22B AND REPLACEMENT OF 1 VALVE BONNET STUD.
8. Tests conducted Hydrostatic R Pneumatic r] Nominal Operating Pressure E Exempt 1 Other D Pressure 750 psi Test Temp. 63 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 11/26/2001 Name of Component: SI-22B Work Order Number: 01-005013 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed £/ffiM geJ~g9U A &OW14 Date Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION Vessel Inspectors I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Ins. Co. of Hartford, CT and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and have inspected the components described in the Owner's Report during the period -74S-D 0 to / 0 2-, and state that measures described to the best of my knowledge and belief, the Owner has performed examinations and taken corrective in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

or implied, concerning By signing this certificate neither the Inspector nor his employer makes any warranty, expressed the Inspector nor the examinations and corrective measures described in this Owner's Report. Furthermore, neither of any kind arising his employer shall be liable in any manner for any personal injury or property damage or a loss from or connected with this inspection.

7 i 4-1, Commissions NB7741, 1, N, IS, A WIS 100024 National Board, State, Province, and Endorsements Inspector' Signature Date a, t-A , / - ,20 01.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation Date 11/27/2001 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 01-005020 Type Code Sym. Stamp N._A
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA Class 2 RESIDUAL HEAT REMOVAL Expiration Date NA
4. Identification of System 34
5. (a) Applicable Construction Code NA Code Case NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Serial No. Board No. ID Built Replacement Stamped Component Manufacturer 681N0277 NA 00127 1970 REPAIRED N APRH1-IA BRYON JACKSON
7. Description of Work INSPECT AND REBUILD CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM RESIDUAL HEAT REMOVAL PUMP 1A.
8. Tests conducted Hydrostatic 7] Pneumatic El Nominal Operating Pressure =l Exempt 1 Other F Pressure 375 psi Test Temp. 341 deg. F
9. Remarks NOT APPLICABLE Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 11/27/2001 Name of Component: APRH1-IA Work Order Number: 01-005020 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed e,C.4 V .. m&Aot. D4ateL ae6.ý 20 Z Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period A,-0o to /- 3 /-0Z , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspector's ignature National Board, State, Province, and Endorsements Date / 20 e .

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl Date 11/2912001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-005030 N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp N.A
3. Work Performed By Nuclear Management Company, LLC 700 First Street. Hudson, Wisconsin 54016 Authorization No. NA CHEMICAL AND VOLUME CONTROL Expiration Date NA
4. Identification of System 35 Class 2 Code Case NA
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Serial No. Board No. ID Built Replacement Stamped Component Manufacturer LD-13 CROSBY VALVE & GAGE NF NA CS014-001 1971 REPAIRED N CO.
7. Description of Work REMOVE FOR TESTING CLASS 2 CHEMICAL AND VOLUME CONTROL SYSTEM 2" VALVE LD-13.
8. Tests conducted Hydrostatic L] Pneumatic F Nominal Operating Pressure El Exempt [:

Other D Pressure 84 psi Test Temp. 87 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturers Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 11/29/2001 Name of Component: LD-13 Work Order Number: 01-005030 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed 6k ý__.*

( y-,4- Date  !

4_ ,20 O.L OV-Owner O or Owner's DeXi Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 1-2S-- 0 to /- 3/- 01, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

7 4 1 Commissions NB7741, I,N, IS, A WIS 100024 nspector'Sqnature National Board, State, Province, and Endorsements Date / ,20 02

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation Date 11/29/2001 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 01-005031
3. Work Performed By Nuclear Management Company, LLC Type Code Sym. Stamp NA 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 35 Class 2 CHEMICAL AND VOLUME CONTROL Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped LD-5 CROSBY ASHTON GAGE NF NA CS109-001 1970 REPAIRED N CO.
7. Description of Work REMOVE FOR TESTING CLASS 2 CHEMICAL AND VOLUME CONTROL SYSTEM 2" VALVE LD-5.
8. Tests conducted Hydrostatic Nominal Operating Pressure 17 1

-- Pneumatic E Exempt 1:1 Other F Pressure 500 psi Test Temp. 250 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 11/29/2001 Name of Component: LD-5 Work Order Number: 01-005031 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed £.

l.e/,aI .T-,44Q/LA Date L- 20 OQ Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-,aS-0O to /-/'-O3.- , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspector' Signature National Board, State, Province, and Endorsements Date 2 * .*,* / ,20 1,,-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl Date 12/4/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant 01-005033 Work Order N490 HWY 42 Kewaunee. WI 54216-9511 Type Code Sym. Stamp N._A
3. Work Performed By Nuclear Management Company, LLC Authorization No. NA 700 First Street, Hudson, Wisconsin 54016 Expiration Date NA
4. Identification of System 36 Class 1 REACTOR COOLANT Code Case NA
5. (a) Applicable Construction Code ASME 111-1968 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components pI1-u, Repaired,or Replaced, Code Name of Manufacturer National Other Year Stamped Name of Built Replacement Board No. ID Component Manufacturer Serial No.

N RCOO8-001 1972 REPLALMN PR-3A CROSBY, ASHTON GAGE NF NA RC008-001 1972 REPLACEME=NT N COMPANY AND REPLACING DICS INSERT.

7. Description of Work REMOVE CLASS 1 REACTOR COOLANT SYSTEM 6" VALVE PR-3A FOR TESTING Nominal Operating Pressure E
8. Tests conducted Hydrostatic El Pneumatic F Exempt [-1 Other El Pressure 2240 psi Test Temp. 5_1 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: . 12/4/2001 Name of Component: PR-3A Work Order Number: 01-005033 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed _____, ______________ Date *g 20 0-1 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period "2S-oO to /- ,/-0,Z , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4 = "Commissions NB7741, I, N, IS, A WIS 100024 Inspector's Signature National Board, State, Province, and Endorsements Date ,20 O

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 12/20/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-005272 N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp N.A
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA Expiration Date NA
4. Identification of System 05B Class 2 AUXILIARY FEEDWATER Code Case NA
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Board No. ID Built Replacement Stamped Component Manufacturer Serial No.

NA F015-002 1972 REPAIRED N

AFW-4B WILLIAM POWELL 61208 N CO.

7. Description of Work REPAIR CLASS 2 AUXILARY FEEDWATER SYSTEM 3" VALVE AFW-4B DUE TO IMPROPER SEATING.

Exempt 1

8. Tests conducted Hydrostatic LI Pneumatic F Nominal Operating Pressure F]

Other D] Pressure 1030 psi Test Temp. 57 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: .12/20/2001 Name of Component: AFW-4B Work Order Number: 01-005272 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed Date *'o _._20 ,20 _

Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors Hartford, CT and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of I-*,* 00 to ,/-,/9*2 , and state that have inspected the components described in the Owner's Report during the period measures described to the best of my knowledge and belief, the Owner has performed examinations and taken corrective in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the Inspector nor the examinations and corrective measures described in this Owner's Report. Furthermore, neither kind arising his employer shall be liable in any manner for any personal injury or property damage or a loss of any from or connected with this inspection.

ln "Commissions NB7741, I,N, IS, A WIS 100024 ignature National Board, State, Province, and Endorsements Inspector's Date t ,20 6-.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 12/20/2001

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 01-005273 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 05B Class 2 AUXILIARY FEEDWATER Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped AFW-4A WILLIAM POWELL NF NA FO15-001 1972 REPAIRED N CO.
7. Description of Work REPAIR CLASS 2 AUXILIARY FEEDWATER SYSTEM 3" VALVE AFW-4A DUE TO IMPROPER SEATING.

Hydrostatic [ Exempt 1

8. Tests conducted Pneumatic Nominal Operating Pressure =V Other D Pressure 1040 psi Test Temp. 57 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: *12/20/2001 Name of Component: AFW-4A Work Order Number: 01-005273 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed PXfluO-A.l 1Z n Ou -v Date 2 0,20 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 9÷S'* 00 to / -3/OV , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, 1,N, IS, A WIS 100024 Inspector'signature National Board, State, Province, and Endorsements Date f -/ ,20 1PZ

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl Date 12/3/2001

1. Owner Wisconsin Public Service Corporation Sheet I of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-007182 N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp N__A
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA Expiration Date NA
4. Identification of System 23 Class 2 CONTAINMENT SPRAY Code Case NA
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Repaired, ASME Manufacturer National Other Year Replaced, or Code Name of Name of ID Built Replacement Stamped Component Manufacturer Serial No. Board No.

REPAIRED N ICS-2B CRANE VALVE NF NA ICS002-002 1970 REPAIRED N CO.

7. Description of Work OPEN FOR MAINTAENANCE CLASS 2 INTERNAL CONTAINMENT SPRAY 8" VALVE ICS-2B.
8. Tests conducted Hydrostatic E Pneumatic r- Nominal Operating Pressure FX Exempt 1"1 Other RI Pressure 30 psi Test Temp. 70.4 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 12/3/2001 Name of Component: ICS-2B Work Order Number: 01-007182 Certificate of Compliance REPAIRED conforms to the rules of the We Certify that the statements made in the report are correct and this ASME Code Section XL. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed / / 4 'f,0Jfl- Date ,20 02 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION Inspectors I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel of Hartford, CT and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co.

to /-3/ -02, and state that have inspected the components described in the Owner's Report during the period '7--2S-9 measures described to the best of my knowledge and belief, the Owner has performed examinations and taken corrective in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

or implied, concerning By signing this certificate neither the Inspector nor his employer makes any warranty, expressed neither the Inspector nor the examinations and corrective measures described in this Owner's Report. Furthermore, a loss of any kind arising his employer shall be liable in any manner for any personal injury or property damage or from or connected with this inspection.

Commissions NB7741, I,N, IS, A WIS 100024 National Board, State, Province, and Endorsements Inspectors Signature Date / 20 _.___,20_

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation Date 12/3/2001 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 01-007183 Type Code Sym. Stamp N__AA
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 23 Class 2 CONTAINMENT SPRAY Expiration Date NA
5. (a) Applicable Construction Code B16.5-1967 Code Case NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped ICS-2A CRANE VALVE NF NA ICS002-001 1970 REPAIRED N CO.
7. Description of Work OPEN FOR MAINTENANCE CLASS 2 INTERNAL CONTAINMENT SPRAY 8" VALVE ICS-2B.
8. Tests conducted Hydrostatic 1-1 Pneumatic 1:1 Nominal Operating Pressure IE Exempt 1 Other D-- Pressure 30 psi Test Temp. 70.4 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 12/3/2001 Name of Component: ICS-2A Work Order Number: 01-007183 Certificate of Compliance REPAIRED conforms to the rules of the We Certify that the statements made in the report are correct and this ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed _.D **e*J L.'i 20 0_

Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION Vessel Inspectors I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure and Ins. Co. of Hartford, CT and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection 0 to I-3 / -V2 , and state that have inspected the components described in the Owner's Report during the period '7-;,'5-'

corrective measures described to the best of my knowledge and belief, the Owner has performed examinations and taken in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

or implied, concerning By signing this certificate neither the Inspector nor his employer makes any warranty, expressed neither the Inspector nor the examinations and corrective measures described in this Owner's Report. Furthermore, or a loss of any kind arising his employer shall be liable in any manner for any personal injury or property damage from or connected with this inspection.

ie, -7 .Commissions NB7741, I,N, IS, A WIS 100024 U p oiorsSignature National Board, State, Province, and Endorsements Da te- .20 01

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 1/14/2002

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Unit No. I
2. Plant Kewaunee Nuclear Power Plant Work Order 01-007184 N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp NA..
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA CONTAINMENT SPRAY Expiration Date NA
4. Identification of System 23 Class 2 Code Case NA
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Repaired, ASME Manufacturer National Other Year Replaced, or Code Name of Name of Stamped Serial No. Board No. ID Built Replacement Component Manufacturer RHR-400B CRANE NA NA ICS006-006 1970 REPAIRED N COMPANY
7. Description of Work OPEN FOR MAINTENANCE CLASS 2 INTERNAL CONTAINMENT SPRAY 6" VALVE RHR-400B DUE TO POSSIBLE DISC TO SEAT GALLING.
8. Tests conducted Hydrostatic Exempt r-1 Pneumatic Nominal Operating Pressure rl Other Pressure 144 psi Test Temp. 87 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 1/14/2002 Name of Component: RHR-400B Work Order Number: 01-007184 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xi. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed f, Date6MAAAM,20

  • Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period I-2S'CD 0 to /J/,OZ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

,2 s 7 a44* Commissions NB7741, I, N, IS, A WIS 100024 (5 p 5iature National Board, State, Province, and Endorsements Date ,20 #-1-_

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 12/20/2001

1. Owner Wisconsin Public Service Corporation Sheet I of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-007185 N490 HWY 42 Kewaunee. WI 54216-9511 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC Authorization No. NA 700 First Street, Hudson, Wisconsin 54016 Expiration Date NNA
4. Identification of System 23 Class 2 CONTAINMENT SPRAY Code Case NA
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Kepalrea, Repaired,or Replaced, Code Name of Name of Manufacturer National Other Year Stamped Board No. ID Built Replacement Manufacturer Serial No.

Component 1970 REPAIRED N NF NA 1C5006-005 ICS006-005 1970 REPAIRED N RHR-400A CRANE COMPANY RHR-400A DUE TO

7. Description of Work OPEN FOR MAINTENENCE CLASS 2 INTERNAL CONTAINMENT SPRAY SYSTEM 6" VALVE POSSIBLE DISC TO SEAT GALLING.
8. Tests conducted Hydrostatic Dl Pneumatic Nominal Operating Pressure r7 Exempt F F Pressure 375 psi Test Temp. 341 deg. F Other
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 12/20/2001 Name of Component: RHR-400A Work Order Number: 01-007185 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed < Date 20 0A Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period '7-1S"-00 to /-$1-t2,, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XL.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I,N, IS, A WIS 100024 pectors Signature National Board, State, Province, and Endorsements Date / 20 J0

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 11/9/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 01-007186 Type Code Sym. Stamp NAA
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA 23 Class 2 CONTAINMENT SPRAY Expiration Date NA
4. Identification of System
5. (a) Applicable Construction Code B16.5-1967 Code Case NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Serial No. Board No. ID Built Replacement Stamped Component Manufacturer ICS-5B CRANE VALVE NF NA ICS006-003 1970 REPAIRED N CO.
7. Description of Work OPEN FOR REPAIR CLASS 2 CONTAINMENT SPRAY SYSTEM 6" VALVE ICS-5B DUE TO DISC TO SEAT GALLING.
8. Tests conducted Hydrostatic D- Pneumatic D Nominal Operating Pressure n Exempt F Other D Pressure 280 psi Test Temp. 75 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date:. 11/9/2001 Name of Component: ICS-5B Work Order Number: 01-007186 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed A A*A*h

&Q lT'/c,2*.

acW*U t Date 4 ,20 0.1 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owners Report during the period 7_-_'_o to I/-'S-, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

w o--: Commissions NB7741, I, N, IS, A WIS 100024 iignature National Board, State, Province, and Endorsements

,20 6

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl Date 11/9/2001

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511 Work Order 01-007187 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson. Wisconsin 54016 Authorization No. NA
4. Identification of System 23 Class 2 CONTAINMENT SPRAY Expiration Date NA
5. (a) Applicable Construction Code B16.5-1967 Code Case NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Serial No. Board No. ID Built Replacement Stamped Component Manufacturer ICS-6B CRANE VALVE NF NA ICS006-004 1970 REPAIRED N CO.
7. Description of Work OPEN FOR MAINTENANCE CLASS 2 CONTAINMENT SPRAY SYSTEM 6" VALVE ICS-6B DUE TO DISC TO SEAT GALLING.
8. Tests conducted Hydrostatic El Pneumatic Nominal Operating Pressure I*

Exempt 1 Other El Pressure 280 psi Test Temp. Z5 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 11/9/2001 Name of Component: ICS-6B Work Order Number: 01-007187 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed eI "a, &JV.AnJ AAJ Date l i ,20 0O.1 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period '7- 2Y-,0 to /-JI/-0 X, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

,Commissions NB7741, I, N, IS, A WIS 100024 National Board, State, Province, and Endorsements V Inspector's 11gnature Date ,20 60.1

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 9/7/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-013239 N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA Class 1 SAFETY INJECTION Expiration Date NA
4. Identification of System 33
5. (a) Applicable Construction Code B16.5-1967 Code Case NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Serial No. Board No. ID Built Replacement Stamped Component Manufacturer SI-304A VELAN VALVE NF NA SI116-005 1967 REPAIRED N CORPORATION
7. Description of Work TORQUE BOLTING ON CLASS 1 SAFETY INJECTION SYSTEM 6" VALVE SI-304A DUE TO EVIDENCE OF LEAKAGE.
8. Tests conducted Hydrostatic F Pneumatic D Nominal Operating Pressure 1:1 Exempt El Other -- Pressure 0 psi Test Temp. 0 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 9/7/2001 Name of Component: SI-304A Work Order Number: 01-013239 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed Date 20 C.

Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7t.4"O to /-3/-#;L , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

A ?-3" 7~t",Commissions NB7741, 1, N, IS, A WIS 100024 National Board, State, Province, and Endorsements Inspecr's Signature I"

Da tetej 20 ~

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 8/20/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-013438 N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp N.A
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA Expiration Date NA
4. Identification of System 35 Class 2 CHEMICAL AND VOLUME CONTROL
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section X1 Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Serial No. Board No. ID Built Replacement Stamped Component Manufacturer CVC-4C GRINNELL FIRE NF NA CS033-005 1973 REPAIRED N PROTECTION SYSTEMS
7. Description of Work TORQUE BOLTING ON CLASS 2 CHEMICAL AND VOLUME CONTROL SYSTEM 3" VALVE CVC-4C DUE TO BODY TO BONNET LEAK.
8. Tests conducted Hydrostatic 1I- Pneumatic L] Nominal Operating Pressure El Exempt El Other F Pressure 23 psi Test Temp. 11_5 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 8/20/2001 Name of Component: CVC-4C Work Order Number: 01-013438 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed 1CA AAX.L.A ,7T- CJ* t Date 20 6,20 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 74--'O0 to /-3/-D2- , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, 1, N, IS, A WIS 100024 Inspectors Signature National Board, State, Province, and Endorsements Date 20 O;

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation Date 11/21/2001 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2
2. Plant Kewaunee Nuclear Power Plant Unit No. 1 N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 01-014566
3. Work Performed By Nuclear Management Company, LLC Type Code Sym. Stamp NA 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 34 Class 2 RESIDUAL HEAT REMOVAL Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped RHR-100B CRANE VALVE NF NA AC010-008 1972 REPAIRED N CO.
7. Description of Work OPEN FOR REPAIR CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM 8" VALVE RHR-100B.
8. Tests conducted Hydrostatic Pneumatic 1 Nominal Operating Pressure El Exempt LI Other D Pressure 114 psi Test Temp. 87 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: .11/21/2001 Name of Component: RHR-100B Work Order Number: 01-014566 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed __.JA CA)Jt Date .20 0 ca, Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 74So-' to 3/ 1'-2-, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 a.nspector's'gnature National Board, State, Province, and Endorsements Date / 20 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation Date 11/27/2001 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 01-014567 Type Code Sym. Stamp NA
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA
4. Identification of System 34 Class 2 RESIDUAL HEAT REMOVAL Expiration Date NA
5. (a) Applicable Construction Code B31.1-1967 Code Case NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No. Board No. ID Built Replacement Stamped RHR-100A CRANE VALVE NF NA AC010-007 1972 REPAIRED N COMPANY
7. Description of Work REPAIR CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM 8" VALVE RHR-100A.
8. Tests conducted Hydrostatic LII Pneumatic Nominal Operating Pressure L Exempt 1 Other 1: Pressure 340 psi Test Temp. 189 deg. F
9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: .11/27/2001 Name of Component: RHR-100A Work Order Number: 01-014567 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed *W . 1k: ALN 0 111 flh1, Date 20 0.__

Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT that have inspected the components described in the Owner's Report during the period '7-;S'00 to I 3/'-0Z, and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

A ý nCommissions NB7741, I,N, IS, A WIS 100024 Inspe or's Signature National Board, State, Province, and Endorsements Date - **. 20 -0

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI Date 9/5/2001

1. Owner Wisconsin Public Service Corporation Sheet 1 of 2 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Unit No. 1
2. Plant Kewaunee Nuclear Power Plant Work Order 01-014609 N490 HWY 42 Kewaunee, WI 54216-9511 Type Code Sym. Stamp N.A
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson. Wisconsin 54016 Authorization No. NA Expiration Date NA
4. Identification of System 35 Class 2 CHEMICAL AND VOLUME CONTROL Code Case NNA
5. (a) Applicable Construction Code NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Repaired, ASME Manufacturer National Other Year Replaced, or Code Name of Name of Serial No. Board No. ID Built Replacement Stamped Component Manufacturer AJAX IRON 6577 NA 00077 1967 REPAIRED N APCH-1C WORKS
7. Description of Work REPAIR CLASS 2 CHEMICAL AND VOLUME CONTROL SYSTEM CHARGING PUMP 1C (SUCTION VALVE REPAIR).
8. Tests conducted Hydrostatic Pneumatic 1: Nominal Operating Pressure El Exempt El Other R Pressure 20 psi Test Temp. 112 deg. F
9. Remarks NOT APPLICABLE Applicable Manufacturer's Data Reports to be Attached

NIS-2 (Back)

Sheet 2 of 2 Date: 9/5/2001 Name of Component: APCH-1C Work Order Number: 01-014609 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed " e*. 640-*pao* Date * ,20 0 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 1-2r-0 0 to /__3_-_ 2_, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

lns Jtr Commissions NB7741, I, N, IS,A WIS 100024 Inspector's Signature National Board, State, Province, and Endorsements Date / 20 0 ,