ML020720559

From kanterella
Jump to navigation Jump to search
Part 1 of 2, Kewaunee Nuclear Power Plant, 2001 Inservice Inspection (ISI) Summary Report
ML020720559
Person / Time
Site: Kewaunee 
Issue date: 02/22/2002
From: Coutu T
Nuclear Management Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NRC-02-015
Download: ML020720559 (164)


Text

Kewaunee Nuclear Power Plant Point Beach Nuclear Plant N490 Highway 42 6610 Nuclear Road Kewaunee, Wl 54216-9511 Two Rivers, Wl 54241 NM C 920.388.2560 920.755.2321 Committed to Nuclear Excellence Kewaunee / Point Beach Nuclear Operated by Nuclear Management Company, LLC NRC-02-015 February 22, 2002 10CFR50.55a U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555 Ladies and Gentlemen:

Docket 50-305 Operating License Kewaunee Nuclear Power Plant 2001 Inservice Inspection (ISI) Summary Report As required by ASME Boiler and Pressure Vessel Code,Section XI; Code of Federal Regulation 10CFR50.55a; and Wisconsin Administrative Code, Subchapter V ILHR 41.55(3) and ILHR 41.56; various ISI examinations were performed as part of the 2001 Refueling Outage. The outage took place from September 24, 2001 through December 4, 2001; i.e. closing of G1. This letter transmits the Inservice Inspection Summary Report as required by paragraph IWA-6230 of Section XI.

Two separate ASME Section XI inservice examination programs are implemented at the KNPP.

One program is for pressure retaining piping/vessel and component supports and the other program for the metal containment. The 2001 refueling outage constituted the first inspection year of the third period of the third interval for the piping/vessel and component support program, including preservice examinations associated with steam generator replacement. The 2001 refueling outage was also the first inspection year of the second period of the first interval for the metal containment program. Examinations for the piping/vessel and component support program, including preservice examinations associated with steam generator replacement, were performed in accordance with the ASME Boiler and Pressure Vessel Code Section XI 1989 Edition. Examinations for the metal containment program were performed in accordance with the 1992 Edition up to and including the 1992 Addenda of Section XI of the ASME Boiler and Pressure Vessel Code. These requirements were implemented in accordance with the "Kewaunee Nuclear Power Plant Third Ten-Year Inservice Inspection (ISI) Program 1994-2004," "Kewaunee Nuclear Power Plant First 10-Year Inservice Inspection Class MC (ISI) Program 1996-2006," Plant Technical Specifications, and nondestructive examination procedures.

Docket 50-305 NRC-02-015 February 22, 2002 Page 2 The following items were examined for Class 1, Class 2, Class 3 Components and their supports:

1. Reactor Vessel Closure Head Flange Weld
2. Reactor Vessel Closure Head Studs, Nuts, Washers and Control Rod Drive Mechanisms
3. Pressurizer Circumferential and Longitudinal Welds
4. Steam Generator Head Circumferential Weld, Nozzle Inside Radius Sections and Nozzle To Shell Weld
5. Reactor Coolant Pump Main Flange Bolting and No. 1 Seal Housing Bolting
6. Seal Water Injection Filter Shell Circumferential Weld
7. Letdown Heat Exchanger Head Circumferential Weld
8. Charging Pump Pulsation Dampener Head Circumferential Weld
9. Class 1 Valve Bodies
10. Class 1 and Class 2 Piping Welds
11.

Class 1 Piping Integrally Welded Attachment

12. Class 2 Piping Integrally Welded Attachments
13.

Class 2 Safety Injection Pump Casing Weld and Welded Attachments

14. Class 1, Class 2 and Class 3 Piping and Component Supports and Hangers
15. Class 1 and Class 2 Reactor Vessel Conoseal Bolting, Pressurizer Manway Bolting, Flange Bolting and Valve Bonnet Bolting
16. Class 1 System Leakage Test
17. Class 2 and Class 3 System Inservice and Functional System Pressure Tests The following items were examined for the Replacement Steam Generators:
1. Replacement Steam Generators: Tubesheet to Head Welds, Nozzle Inside Radius Sections, Nozzle to Safe End Butt Welds, Primary Side Manway Bolting, Integrally Welded Attachments, Shell Circumferential Welds, Tubesheet to Shell Welds and Class 1 Support Components
2. New Class 1 Reactor Coolant Piping Welds
3. New and Replacement Class 2 Main Steam and Feedwater Piping Welds
4. Reexamination of Existing Steam Generator, Circumferential Welds SG-W2 and SG-W10 to verify previously recorded Ultrasonic Planar Indications
5. Existing 16", 8" and 1" Feedwater Inside Diameter Surfaces
6. Existing Steam Generator Inside Diameter Feedwater Nozzle Inner Radius and Shell Circumferential Welds
7. Existing Steam Generator Class 2 Supports

Docket 50-305 NRC-02-015 February 22, 2002 Page 3 The following items were examined for the Class MC Reactor Building Containment Vessel:

1. Accessible Surface Areas
2. Longitudinal Welds and Circumferential Welds
3. Sleeve to Bellows Welds
4. Flange Welds
5. Seals and Gaskets
6. Moisture Barriers
7. Dissimilar Metal Welds
8. Bolted Connections
9. Containment Penetration Bellows
10. Airlocks The following items were examined in accordance with Kewaunee Nuclear Power Plant Technical Specifications:
1. Eddy Current Testing of Replacement Steam Generators
2. Functional Testing, Disassembly and Overhaul of Steam Generator 900 KIP Hydraulic Snubbers In addition, the following examinations were performed in excess of ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Requirements and included:
1. Portions of the Service Water System were radiographed for wall loss, pits, nodules, and sand, mud or other sediments.
2. Balance of plant piping subject to erosion/corrosion was examined by radiographic, ultransonic, and visual techniques.

Docket 50-305 NRC-02-015 February 22, 2002 Page 4 Please find attached a copy of the following documentation that summarizes the inservice inspection activities and results for the Kewaunee Nuclear Power Plant 2001 Refueling Outage.

1. Summary of recordable indications and a description of how they were dispositioned (Attachment 1)
2. Summary of Class 1 and 2 Repairs and Replacements of Components 1 inch in diameter or smaller (Attachment 2)
3. Form NIS-1 Owner's Report for Inservice Inspections of Class 1, Class 2, and Class 3 Components (Attachment 3)
4. Form NIS-I Owner's Report for Inservice Inspections for Class MC Components (Attachment 4)
5. Form NIS-I Owner's Report for Inservice Inspections of Replacement Steam Generators (Attachment 5)
6. Form NIS-2 Owner's Report for Repair or Replacements (74 Total) (Attachment 6)
7. Examination Summary for Scheduled and Augmented Inservice Inspection (ISI) Program (Attachment 7)
8. Examination Summary for Inservice Inspection (ISI) Class MC Program (Attachment 8)
9. Examination Summary for Preservice Inspection (PSI) of Steam Generators (Attachment 9)
10. Examination Summary for Replacement Steam Generator Eddy Current (Attachment 10)
11.

Examination Summary for Steam Generator 900 KIP Hydraulic Snubbers (Attachment 11)

12. A summary of examinations which were limited by geometric, metallurgical, or design/access restrictions and their associated data sheets (Attachment 12)

The final reports for each of these examinations are on file in the QA/QC Records Vault at the Kewaunee Nuclear Power Plant. These records are available for review as deemed necessary.

Additional Comments The next Refueling Outage at the Kewaunee Nuclear Power Plant is tentatively scheduled for April 4, 2003 through April 30, 2003.

Sincerely, Thomas Coutu Manager-Kewaunee Plant PEB/CAT Attach.

cc -

U.S. NRC - Region III (w/o attach)

U.S. NRC - Senior Resident Inspector (w/o attach)

ATTACHMENT 1 Letter from T. Coutu (NMC)

To Document Control Desk (NRC)

Dated February 22, 2002 Summary of Recordable Indications and Description of Disposition

Docket 50-305 NRC-02-015 February 22, 2002, Page 1 TABLE 1 TYPE OR LOCATION OF RECORDABLE i

O INDICATION (RI)

METHOD NO. OF RI'S Reactor Vessel Closure Head Flange Weld Surface (MT) 1 Weld Steam Generator Circumferential Head Weld Volumetric (UT) 1 Weld Seal Water Injection Filter Shell Weld Volumetric (UT) 1 Weld Piping Integrally Welded Attachment Surface (PT) 1 Weld Piping Circumferential Butt Weld Surface (PT) 1 Weld Piping Socket Weld Surface (PT) 1 Weld Reactor Vessel Conoseal Bolting Visual (VT-3) 1 Conoseal RC Pump No. 1 Seal Housing Bolting Visual (VT-1) 1 Pump Pressurizer Manway Bolting Visual (VT-3) 1 Manway Component Supports and Hangers Visual (VT-3) 31 Supports Valve Bonnet Bolting Visual (VT-1) 1 Valve Valve Bonnet Bolting Visual (VT-3) 6 Valves System Pressure Tests Visual (VT-2) 51 Items Replacement Steam Generator Integrally Welded Surface (MT) 1 Weld Attachment SG-1B-23B Replacement Steam Generator Tubesheet To Head Weld Volumetric (UT) 1 Weld SG-W32 Replacement Steam Generator Primary Side Manway SG-Visual (VT-i) 1 Stud 1B-CLMWB Replacement Steam Generator Tubesheet To Shell Weld Volumetric (UT)

I Weld SG-W31 Existing Steam Generator Feedwater Nozzle Inner Radius Surface (MT) 1 Nozzle SG-IR8 Existing Steam Generator Feedwater Nozzle Inner Radius Surface (MT) &

1 Nozzle SG-IR16 Visual (VT-1)

Existing Steam Generator Circumferential Welds SG-W2 Volumetric (UT) 2 Welds and SG-W10 Existing 16", 8" and 1" Feedwater Piping FW-W27BC Surface (MT) 1 ID Section Existing 16", 8", and 1" Feedwater Piping FW-W55BC Surface (MT) &

1 ID Section Visual (VT-1)

Reactor Building Containment Vessel General Visual 11 Plates Reactor Building Containment Vessel Moisture Barriers VT-3 5 Plates Reactor Building Containment Vessel Emergency Airlock VT-1 1 Bolt

Docket 50-305 NRC-02-015 February 22, 2002, Page 2 Disposition of Class 1, Class 2, and Class 3 indications have been completed in accordance with the rules of ASME Boiler and Pressure Vessel Code Section XI 1989 Edition and ASME Boiler and Pressure Vessel Code Section XI 1992 Edition up to and including 1992 Addenda for Class MC Components. Applicable codes, standards, and engineering criteria were used to disposition indications associated with the non-code-required examinations.

Recordable indications for Class 1, Class 2, Class 3 and Class MC have been dispositioned as summarized below:

1. A 0.125" long linear indication was recorded on the Reactor Vessel Closure Head Flange Weld RV-W12 during performance of magnetic particle examination. This linear indication was acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWB-3510-3.
2. A spot indication on Steam Generator 1B Circumferential Head Weld SG-W9 was recorded during performance of ultrasonic examination. This ultrasonic spot indication was acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWC-3510-1.
3. Five (5)laminar indications combined into four (4) laminar indications due to proximity of the indications. The indications are on seal water injection filter IA circumferential shell weld AFSI-Wl and were identified during performance of ultrasonic examinations. These laminar indications were acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWC-3510-2 and were typical of laminations recorded on seal water injection filters 1A and 1B during Refueling Outages 1982, 1986, 1988, 1992 and 1998.
4. Three (3) rounded indications (0.625", 0.125" and 0.1875" in diameter) were recorded on 2" piping integrally welded attachment RSI-H72 during performance of liquid penetrant examinations. These three (3) rounded indications were acceptable per ASME Boiler and Pressure Vessel Code Section III 1989 Edition Section NC-5352(b).
5. A 0.125" long linear indication and a 0.125" rounded indication were recorded on 6" diameter Circumferential Butt Weld ICS-W43 during performance of liquid penetrant examinations. The 0.125" long linear indication was acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWB-3514-2. The 0.125" rounded indication was acceptable per ASME Boiler and Pressure Vessel Code Section III 1989 Edition Section NC-5352.
6. A 0.55" long linear indication on 2" diameter socket weld SI-W6S was recorded during performance of liquid penetrant examinations. This linear indication was unacceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWB-3514-2. The linear indication was removed under Work Order 01-016342 by light filing with a jewelers file, reexamined and accepted with no indications.

Docket 50-305 NRC-02-015 February 22, 2002, Page 3

7. Visual (VT-1, VT-2 and VT-3) indications were recorded on reactor vessel conoseal bolting, reactor coolant Pump No. 1 seal housing bolting, pressurizer manway bolting, valve bonnet bolting, piping supports and hangers and during system pressure tests. The indications were either (1) evaluated and accepted or (2) repaired, reexamined and accepted by: Nuclear Management Company, LLC - Maintenance, Quality Control, Engineering and Technical Support or Inservice Inspection Personnel and reviewed by the Authorized Nuclear Inservice Inspector.
8. Two (2) separate linear indications on replacement steam generator 1B integrally welded attachment SG-1B-23B were recorded during performance of magnetic particle examinations.

These two linear indications due to their close proximity to each other were classified as one linear indication with a length of 0.21875." This linear indication was acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Sections IWB-3516.1, IWB-3510.3 and IWB-3510-3.

9. Ultrasonic recordable indications at three separate locations on replacement steam generator lB tubesheet to head weld SG-W32 were noted during performance of manual ultrasonic examinations. These three separate planar indications were acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWB-3510-1.
10. One visual indication was recorded by the VT-1 method on replacement steam generator 1B primary side manway stud SG-1B-CLMWB#17. Although this primary manway stud was acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Section IWB-3517.1 (b), a new VT-1 acceptable replacement stud was installed.
11. Ultrasonic recordable indication at one location on replacement steam generator 11B tubesheet to shell weld SG-W31 was noted during performance of manual ultrasonic examination. This planar indication was acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWC-3510-1.
12. Recordable indications on the existing steam generator lB feedwater nozzle inside radius section SG-IR8 were recorded during augmented examination by magnetic particle. These indications were repaired by Bechtel Corporation under Bechtel's NCR's and Kewaunee Nuclear Power Plant Work Orders as part of replacement steam generator activities.
13. Recordable indications on the existing steam generator 1A feedwater nozzle inside radius section SG-IR16 were recorded during augmented examinations by magnetic particle and visual (VT-1) methods. These indications were repaired by Bechtel Corporation under Bechtel's NCR's and Kewaunee Nuclear Power Plant Work Orders as part of replacement steam generator activities.

Docket 50-305 NRC-02-015 February 22, 2002, Page 4 14/15. Prior to severing the existing steam generators and following welding the replacement steam generators to the existing steam generators a manual ultrasonic examination was performed on the existing circumferential shell welds SG-W2 and SG-W10 to ensure that there was no growth in the previously recorded planar indications. These indications were recorded in 1991 for SG W2 and in 1991 and 1996 for SG-Wl0. All indications previously recorded as well as new indications recorded due to amplitude recording criteria change were acceptable either by ASME Boiler and Pressure Vessel Code Section XI 1989 acceptance standards or by fracture analysis as provided in Westinghouse Electric Corporation WCAP 11476 Rev.3 Handbook on Flaw Evaluation, Kewaunee Unit 1 Steam Generator Upper Shell to Cone Weld, May 1991, and evaluation by Kewaunee Nuclear Power Plant during 1996 and 2001 Refueling Outages.

16. Recordable indications on Loop A existing 16", 8" and 1" feedwater piping inner diameter surface for FW-W27BC were recorded during augmented magnetic particle examinations. These indications were repaired by Bechtel Corporation under Kewaunee Nuclear Power Plant Work Orders generated during steam generator replacement activities.
17. Recordable indications on Loop B existing 16", 8" and 1" feedwater piping inner diameter Surface for FW-W55BC were recorded during augmented examinations by magnetic particle and visual (VT-1) methods.

These indications were repaired by Bechtel Corporation under Kewaunee Nuclear Power Plant Work Orders generated during steam generator replacement activities.

18. General visual indication consisting of a 4" x 8" surface defect was recorded on Plate 155. This surface defect was previously recorded and accepted in 1998 and showed no change in dimension or surface condition during the 2001 Refueling Outage.
19. General visual indication consisting of a slight inward bulge on Plates 74, 75, and 83 was recorded. The slight inward bulge was evaluated by Engineering and accepted under Kewaunee Nulcear Power Plant Specification TS-1052, Addendum No. 4, Item No. 19 Section 10.3 - Shell Tolerance.
20. General visual indication consisting of slight outward bulges on Plates 144, 145, 146, 147 and 148 were recorded. The slight outward bulges were evaluated and accepted by Engineering Analysis.
21.

General visual indications consisting of weld deposits on Plate 62 and arc strikes on Plate 99 were recorded and are acceptable per ASME Boiler and Pressure Vessel Code Section XI 1992 Edition 1992 Addenda.

22. VT-3 indications consisting of lack of bonding and tears were recorded in the moisture barriers on Plates 62, 64, 65, 66 and 67 and were repaired under Work Order 0 1-018045.
23. A VT-I indication on an emergency airlock bolt was recorded and was repaired under Work Order 01-018283.

ATTACHMENT 2 Letter from T. Coutu (NMC)

To Document Control Desk (NRC)

Dated February 22, 2002 Summary of Class 1 and 2 Repairs and Replacement of Components 1 inch in Diameter or Smaller

Docket 50-305 NRC-02-015 February 22, 2002, Page 1 The following summarizes the repairs and replacements performed following the 2000 Refueling Outage and during the 2001 Refueling Outage by grinding, buffing, filing, cutting or welding on the Class 1 and Class 2 pressure boundary. These repairs and replacements are in addition to those itemized on the attached Forms "NIS-2 Owner's Report for Repairs or Replacements."

Component Class Reference Repair/Replacement Method 3/4" Valve PS-2A 1

XK-100-10 Cutting and Welding of Replacement Valve 3/4" Valve PS-30 1

XK-100-10 Cutting and Welding of Replacement Valve 1" Valve RC-45A 1

XK-100-10 Cutting and Welding of Replacement Valve and Piping 1" Valve RC-45B 1

XK-100-10 Cutting and Welding of Replacement Valve and Piping Replacement Steam 1

XK-100-10 Repair by Welding Fillet Weld Generator 1B 1/2" Internal Nozzle Drain Line 3/4" Valve 1

XK-100-35 Cutting and Welding of Replacement CVC-21070-1 Valve Replacement Steam 2

M-203 Buffing and Grinding involving Metal Generators 1A and Removal for Arc Strikes, Gouges and 1B: 2", 1" and 3/4" Weld Spatter Piping Replacement Steam 2

M-205 Machining involving Metal Removal for Generators 1A and Pitting 1B Secondary Side Hand Holes

ATTACHMENT 3 Letter from T. Coutu (NMC)

To Document Control Desk (NRC)

Dated February 22, 2002 FORM NIS-1 Owner's Report for Inservice Inspections of Class 1, Class 2, Class 3 Components

Page 1 of 9 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307-9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16,1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

COMPONENT OR APPURTENANCE Reactor Vessel RV Pressurizer PZR Steam Generator SG 1A Steam Generator SG lB Excess Letdown Heat Exchanger AHEL-1A Excess Letdown Heat Exchanger AHEL-1B Class 1 Piping Reactor Coolant Pump RCP-1A Reactor Coolant Pump RCP-1B Residual Heat Exchanger AHRSI-IA MANUFACTURER OR INSTALLER Combustion Engineering Westinghouse Westinghouse/

Ansaldo Energia Milano Westinghouse/

Ansaldo Energia Milano Sentry Sentry Texas Pipe Bending Westinghouse Westinghouse Joseph Oat and Sons MANUFACTURER OR INSTALLER SERIAL NO.

CE69202 1151 1141/0202 1142/0201 3996-5E 3996-6E STATE OR PROVINCE NO.

U11480 U11402 U11400 U11401 U11407 U11408 NATIONAL BOARD NO.

21010 68-23 68-28/151 68-29/150 364 365 1A-1-618J871 GO1 1B-2-618J871 G02 1817-1E U11046 344

Page 2 of 9 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307-9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16, 1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

COMPONENT OR APPURTENANCE Residual Heat Exchanger AHRS2-1B Charging Pump Pulsation Dampener APD-1A Charging Pump Pulsation Dampener APD-1B Charging Pump Pulsation Dampener APD-1C Seal Water Heat Exchanger AHSW Volume Control Tank VCT Regenerative Heat Exchanger ARG Letdown Heat Exchanger AHLD MANUFACTURER OR INSTALLER Joseph Oat and Sons Greer Hydraulics Greer Hydraulics Greer Hydraulics Atlas Joseph Oat and Sons Joseph Oat and Sons Atlas MANUFACTURER OR INSTALLER SERIAL NO.

1817-1F STATE OR PROVINCE NO.

U11424 NATIONAL BOARD NO.

345 GNI-1848 GNI-1846 GNI-1847 734 1787-1C 1831-13 1206 U11404 U11425 U11409 U11410 U11411 U11405 596 376 413 414 415 1031

Page 3 of 9 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307-9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16,1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

COMPONENT OR APPURTENANCE Seal Water Injection Filter AFSI-1A Seal Water Injection Filter AFSI-1B Reactor Coolant Filter AFRC Seal Water Filter AFSW Class 2 Piping Charging Pump APCH-1A Charging Pump APCH-1B Charging Pump APCH-1C Charging Pump APCH-1A Suction Stabilizer MANUFACTURER OR INSTALLER Commercial Filters Commercial Filters AMF Cuno AMF Cuno Texas Pipe Bending Ajax Iron Works Ajax Iron Works Ajax Iron Works Greer Hydraulics MANUFACTURER OR INSTALLER SERIAL NO.

STATE OR PROVINCE NO.

101072 101073 121 123 NATIONAL BOARD NO.

1172 1173 2616 2618 6578 6576 6577 GH1-10234 568

Page 4 of 9 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307-9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16,1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

COMPONENT OR APPURTENANCE Charging Pump APCH-1B Suction Stablizer Charging Pump APCH-1C Suction Stablizer Residual Heat Removal Pump APRHI-IA Residual Heat Removal Pump APRH2-1B Refueling Water Storage Tank Diesel Generator AHDG-1A Cooling Water Exchangers (2)

Diesel Generator AHDG-1B Cooling Water Exchangers (2)

MANUFACTURER OR INSTALLER Greer Hydraulics Greer Hydraulics Byron Jackson Byron Jackson General American Transportation Company ITT Standard Corp.

ITT Standard Corp.

MANUFACTURER OR INSTALLER SERIAL NO.

STATE OR PROVINCE NO.

NATIONAL BOARD NO.

569 GH1-10235 GH1-10236 681N0277 681N0276 C-8297/1969 750797-01-2 750797-01-3 750797-01-1 750797-01-4 570

Page 5 of 9 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307-9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16,1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

COMPONENT OR APPURTENANCE Auxiliary Feedwater Pump APFM-1A Motor Driven Auxiliary Feedwater Pump APFM-1B Motor Driven Auxiliary Feedwater Pump APFT Turbine Driven Class 3 Piping Containment Fan Cooler AHCF-1A Containment Fan Cooler AHCF-1B MANUFACTURER OR INSTALLER Pacific Pump Pacific Pump Pacific Pump Texas Pipe Bending Joy Manufacturing and American Air Filter Joy Manufacturing and American Air Filter MANUFACTURER OR INSTALLER SERIAL NO.

STATE OR PROVINCE NO.

NATIONAL BOARD NO.

46573 46574 46575 GF14402 GF14399

Page 6 of 9 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307-9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16, 1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

COMPONENT OR APPURTENANCE Containment Fan Cooler AHCF-1C Containment Fan Cooler AHCF-1D Safety Injection Pump APSI-1A Safety Injection Pump APSI-1B Safety Injection Pump Lube Oil Cooler AHSC-1A Safety Injection Pump Lube Oil Cooler AHSC-1B Safety Injection Pump Heat Exchangers (2)

AHSC-1A MANUFACTURER OR INSTALLER Joy Manufacturing and American Air Filter Joy Manufacturing and American Air Filter Bingham Pump Bingham Pump Thermxchanger Thermxchanger Borg Warner MANUFACTURER OR INSTALLER SERIAL NO.

STATE OR PROVINCE NO.

NATIONAL BOARD NO.

GF14401 GF14400 290696 290697 X10199A2 X10199A3 854030:854030

Page 7 of 9 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307-9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16, 1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

COMPONENT OR APPURTENANCE Safety Injection Pump Heat Exchangers (2)

AHSC-1B Residual Heat Removal Pump AHRLRP-1A Shaft Seal Heat Exchanger Residual Heat Removal Pump AHRHRP-1B Shaft Seal Heat Exchanger Accumulator Tank ACC-1A Accumulator Tank ACC-1B Containment Spray Pump APCS-1A Containment Spray Pump APCS-1B Containment Spray Pump AIPCS-1A Gland Seal Cooler MANUFACTURER OR INSTALLER Borg Warner Borg Warner Borg Warner Wyatt Wyatt Ingersoll Rand Ingersoll Rand Helliflow MANUFACTURER OR INSTALLER SERIAL NO.

854030:854030 681N0276 681N0276 H-5645-69 H-5644-69 0670-74 0670-75 49486938 STATE OR PROVINCE NO.

NATIONAL BOARD NO.

U11397 U11398

Page 8 of 9 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307-9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16, 1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

COMPONENT OR APPURTENANCE Containment Spray Pump APCS-1B Gland Seal Cooler Component Cooling Pump APCC-1A Component Cooling Pump APCC-1B Service Water Pump APSW-1A1 Service Water Pump APSW-1A2 Service Water Pump APSW-1B1 Service Water Pump APSW-1B2 Spent Fuel Pool Heat Exchanger AHSF Main Steam Moisture Separator Spent Fuel Pool Pump APSF-1A MANUFACTURER OR INSTALLER Helliflow Ingersoll Dresser Pump Flow Serv.

Ingersoll Dresser Pump Flow Serv.

Worthington Pump Worthington Pump Worthington Pump Worthington Pump Struther Wells Wright Austin Gould Pumps MANUFACTURER OR INSTALLER SERIAL NO.

6080694 0600009 0600010 VTP27737 75 TU-1719-1 VTP27736 VTP27739 1-68-06-1519 6230 STATE OR NATIONAL PROVINCE NO.

BOARD NO.

U11445 X.R.

6008 786A519.1

Page 9 of 9 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307-9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16, 1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

COMPONENT OR APPURTENANCE Spent Fuel Pool Pump APSF-1B Service Water Pump Strainer ASSW-1A1 Service Water Pump Strainer ASSW-1A2 Service Water Pump Strainer ASSW-1B1 Service Water Pump Strainer ASSW-1B2 Component Cooling Heat Exchanger AHCC1-IA Component Cooling Heat Exchanger AHCC2-1B MANUFACTURER OR INSTALLER Gould Pumps S.P. Kinney Engineers S.P. Kinney Engineers S.P. Kinney Engineers S.P. Kinney Engineers Engineers and Fabricators Engineers and Fabricators MANUFACTURER OR INSTALLER SERIAL NO.

786A519.2 2278 2279 2280 2281 S-15748-A S-15748-B STATE OR PROVINCE NO.

U11426 U11427 NATIONAL BOARD NO.

1139 1140

FORM NIS-1 (Back)

8. Examination Dates March 27,2001 to December 6, 2001
9. Inspection Period Identification 3rd
10. Inspection Interval Identification 3rd 1989 None
11. Applicable Edition of Section XI 1989 Addenda
12. Date/Revision of Inspection Plan November 27,2000/Revision 2
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. Reference Tab C
14. Abstract of Results of Examinations and Tests.

Reference Tab B and Tab F

15. Abstract of Corrective Measures. Reference Tab B and Tab F Utilization of ASME Boiler and Pressure Vessel Code Section XI:

Code Cases N-416-1, N-416-2, N-460, N-491, N-498 and N-498-1.

We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASMIE Code,Section X.

Certificate of Authorization No. (if applicable)

'",/-'

Expiration Date Date K o Signed W Z

-4A1e..,

cua-'u J

20 Owner By~-

A CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of W1 I.OwNSiA and employed by NAxt-r-Fato SrmA, Lci',

-r" of 4AA'rgoi*o C.-.

have inspected the components described in this Owner's Report during the period AfAR*,.4

,'-7,,avo/

to

-e,

, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4,-__

Commissions A"'72

/ eo190s/

11( *'T

/

s 6Signature National Board, State. Province, and Endorsements Date A3 A

ATTACHMENT 4 Letter from T. Coutu (NMC)

To Document Control Desk (NRC)

Dated February 22, 2002 FORM NIS-1 Owner's Report for Inservice Inspections for Class MC Compenents

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307-9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16,1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

COMPONENT OR APPURTENANCE Reactor Building Containment Vessel Personnel Airlock MANUFACTURER OR INSTALLER Chicago Bridge and Iron Company Chicago Bridge and Iron Company MANUFACTURER OR INSTALLER SERIAL NO.

C4454 C4454 STATE OR NATIONAL PROVINCE NO.

BOARD NO.

U11423 U11423

FORM NIS-1 (Back) 8, Examination Dates September 18, 2001 to December 4, 2001

9. Inspection Period Identification
10. Inspection Interval Identification 2nd 1st 1992 1992
11. Applicable Edition of Section XI

______________Addenda

12. Date/Revision of Inspection Plan September 26, 2000/Revision 1
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan.

Reference Tab C

14. Abstract of Results of Examinations and Tests.

Reference Tab B and Tab F

15. Abstract of Corrective Measures. Reference Tab B and Tab F We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code, Section

)a.

Certificate of Authorization No. (if applicable)

Date A

a Q3 Signed J

2,1, WI Expiration Date p 5 6-j~c_

e-c Owner By National Board. State, Province. and Endorsements CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of __

___and employed by //A r10F*e )

,7-6AbM13 It-r f

/4CAR7"FI C r have inspected the components described in this Owner's Report during the period Rdi001 t

/e IOV, 200 ', and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or con:a with t inspecion.

Commissions

,,.'4

" '/A./S

/

2", 'V,

'4

ATTACHMENT 5 Letter from T. Coutu (NMC)

To Document Control Desk (NRC)

Dated February 22, 2002 FORM NIS-1 Owner's Report for Inservice Inspections of Replacement Steam Generators

Page 1 of 2 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307-9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16, 1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

COMPONENT OR APPURTENANCE Steam Generator SG 1A Steam Generator SG 1B Steam Generator SG 1A Steam Generator SG lB Steam Generator IA Safe End Welds Steam Generator 1B Safe End Welds Class 1 Reactor Coolant Piping Installation Welds Class 2 Main Steam Piping Installation Welds MANUFACTURER OR INSTALLER Ansaldo Energia Milano Ansaldo Energia Milano Westinghouse Westinghouse Ansaldo Energia Milano Ansaldo Energia Milano Bechtel Corporation Bechtel Corporation MANUFACTURER OR INSTALLER SERIAL NO.

0202 0201 1141 1142 NA NA NA NA STATE OR PROVINCE NO.

U11400 U11401 U11400 U11401 NA NA NA NA NATIONAL BOARD NO.

151 150 68-28 68-29 NA NA NA NA

Page 2 of 2 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. OWNER - WISCONSIN PUBLIC SERVICE CORPORATION, 700 NORTH ADAMS, P.O. BOX 19001, GREEN BAY, WISCONSIN 54307-9001
2. PLANT - KEWAUNEE, N490 HIGHWAY 42, KEWAUNEE, WISCONSIN 54216-9511
3. PLANT UNIT - NO. 1
4. OWNER CERTIFICATE OF AUTHORIZATION - N/A
5. COMMERCIAL SERVICE DATE - JUNE 16,1974
6. NATIONAL BOARD NUMBER FOR UNIT - N/A
7. COMPONENTS INSPECTED -

COMPONENT OR APPURTENANCE Class 2 Feedwater Piping Installation Welds Class 2 Feedwater Nozzle Adapter and Nozzle to Pipe Installation Welds MANUFACTURER OR INSTALLER Bechtel Corporation Bechtel Corporation MANUFACTURER OR INSTALLER SERIAL NO.

NA NA STATE OR PROVINCE NO.

NA NA NATIONAL BOARD NO.

NA NA

FORM NIS-1 (Back)

8. Examination Dates June 4, 2001 December 4, 2001
9. Inspection Period Identification 3rd
10. Inspection Interval Identification 3rd 1989 None
11. Applicable Edition of Section XI 1989 Addenda
12. Date/Revision of Inspection Plan November 27, 2000/Revision 2
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan.

Reference Tab C

14. Abstract of Results of Examinations and Tests. Reference Tab B and Tab F
15. Abstract of Corrective Measures. Reference Tab B and Tab F Utilization of ASME Boiler and Pressure Vessel Code Section XI: Code Cases N-416-2 and N-460.

We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable)

Expiration Date

/

Date a\\.JA4 CC, A.VQ3~ *QO Signed C-)J I I'~

L~.

By J

Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of 0A:i.o C-0 "T I,.-

and employed by HA./,-rgao ST4Mi Boller CTr. of 4-e1-/o,'e-) r r" have inspected the components described in this Owner's Report during the period

,&,Tte,

,,,0 O/

to A '9 "/,

and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or cone wit this inspection.

Commissions /

7 9" V/ Al/.S /OO"at XZ !ý 4.,

A J

c,.Actor's Signature National Board. State. Province. and Endorsements V

ATTACHMENT 6 Letter from T. Coutu (NMC)

To Document Control Desk (NRC)

Dated February 22, 2002 FORM NIS-2 Owner's Report for Repair or Replacement (74 Total)

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson. Wisconsin 54016
4. Identification of System 33 Class 2 SAFETY INJECTION
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section X1 Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Manufacturer ITT GRINNELL VALVE COMPANY Manufacturer Serial No.

NA National Board No.

NA Other ID NA Date 11/1/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-016956 Type Code Sym. Stamp N..A Authorization No. NA Expiration Date NA Code Case NA Year Built 1967

Repaired, ASME
Repaired, Replaced, or Replacement REPAIRED
7. Description of Work REPAIR CLASS 2 SAFETY INJECTION SYSTEM 2" HANGER RSI-H70 DUE TO MISSING JAM NUT.
8. Tests conducted Hydrostatic Other DJ D

Pneumatic Pressure F

Nominal Operating Pressure psi Test Temp.

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached Name of Component RSI-H70 ASME Code Stamped N

D:

deg. F Exempt 17 N

NIS-2 (Back)

Sheet 2 of 2 Date:

11/1/2001 Name of Component:

RSI-H70 Work Order Number: 01-016956

.20 _____

Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XL.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed Date 20 0A Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-;5'i0" to /-3/1

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 National Board, State, Province, and Endorsements pectors nature

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 33 Class 2 SAFETY INJECTION
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component RSI-H73 Name of Manufacturer ITT GRINNELL VALVE COMPANY Manufacturer Serial No.

NA National Board No.

NA NA 1967 XtzHAIh(tU

'4 Other ID Date 11/1/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-016956 Type Code Sym. Stamp NA Authorization No.

NA Expiration Date N.A Code Case NAA Year Built

Repaired, AM 

Repairedl, Replaced, or Replacement

7. Description of Work REPAIR CLASS 2 SAFETY INJECTION SYSTEM 2" HANGER RSI-H73 DUE TO UNSPREAD COTTER PIN.
8. Tests conducted Hydrostatic Other n

El Pneumatic Pressure El psi Nominal Operating Pressure Test Temp.

--]

Exempt deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped REPAIRED NA 1967 NA

NIS-2 (Back)

Sheet 2 of 2 Date:. 11/1/2001 Name of Component:

RSI-H73 Work Order Number: 01-016956 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed ZSA4*V

. *Jg?

A o it.

J OL, M Date

,20 L

Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-,T-" to /- -3/-02., and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

s uCommissions NB7741, I, N, IS, A WIS 100024 pectors Signature National Board, State, Province, and Endorsements Date 20 o'-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation Date 11/1 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1
2. Plant Kewaunee Nuclear Power Plant Unit No.

N490 HWY 42 Kewaunee. WI 54216-9511 Work Order

3. Work Performed By Nuclear Management Company, LLC Type Code 700 First Street, Hudson, Wisconsin 54016 Authorizatio
4. Identification of System 33 Class 2_

SAFETY INJECTION Expiration D

5. (a) Applicable Construction Code B31.1-1967 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component RSI-H74 Name of Manufacturer ITT GRINNELL VALVE COMPANY Manufacturer Serial No.

NA National Board No.

NA Other ID NA 1967 REPAIIU Year Built

/2001 of 2 1

01-016956 Sym. Stamp NA nNo.

NA late NA NA Repa*ired, Replaced, or Replacement

7. Description of Work REPAIR CLASS 2 SAFETY INJECTION 2" HANGER RSI-H74 DUE TO LOOSE NUT.
8. Tests conducted Hydrostatic Other D Pneumatic F

Pressure Nominal Operating Pressure psi Test Temp.

El Exempt [-7 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached MIYI

Code Stamped REPAIRED 1967 NA

NIS-2 (Back)

Sheet 2 of 2 Date:

11/1/2001 Name of Component:

RSI-H74 Work Order Number: 01-016956 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed 44&

L-"O Date 4Ak M

,20 0 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7--V-1V to /-*i"-2,, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4 12

.,0 Commissions NB7741, I, N, IS, A WIS 100024 Dae-20 National Board, State, Province, and Endorsements t

nspector's

,2nature

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson. Wisconsin 54016
4. Identification of System 05A Class 2 FEEDWATER
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section X1 Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component FDW-H170 Name of Manufacturer ITT GRINNEL COMPANY Manufacturer Serial No.

NF National Board No.

NA Other ID NA 1967 REPAI RED N

Date 11/16/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-018043 Type Code Sym. Stamp NA Authorization No.

NA Expiration Date NNA Code Case NA Year Built NepI[u, MOIViE

Repaired, Replaced, or Replacement
7. Description of Work REPAIR CLASS 2 FEEDWATER SYSTEM 16" SUPPORT FDW-H170 DUE TO LOOSE NUTS.
8. Tests conducted Hydrostatic F

Other D Pneumatic D-]

Pressure Nominal Operating Pressure psi Test Temp.

1:1 Exempt E' deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached Code Stamped REPAI RED IN 1967 NA

NIS-2 (Back)

Sheet 2 of 2 Date: 11/16/2001 Name of Component:

FDW-H170 Work Order Number: 01-018043 Date

/

20 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed PC/W.t"J.VJ.,l.W.dI0, V2l"J Date

,20 a Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-.2)VP to /-/-#1, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024

ýnspectors ý4nature National Board, State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 05B Class 2 AUXILIARY FEEDWATER
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component FDW-H39 Name of Manufacturer ITT GRINNEL COMPANY Manufacturer Serial No.

NA National Board No.

NA Other ID NA 1967 REPAIRED N

Date 11/16/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-018044 Type Code Sym. Stamp N.A Authorization No. NA Expiration Date NA Code Case NA Year Built

Repaired, ASME
Repaired, Replaced, or Replacement
7. Description of Work REPAIR CLASS 2 AUXILIARY FEEDWATER SYSTEM 3" HANGER FDW-H39 DUE TO LOOSE NUT ON PIPE CLAMP.
8. Tests conducted Hydrostatic Other F

El Pneumatic Pressure Nominal Operating Pressure psi Test Temp.

D:

deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped Exempt []

REPAIRED N

1967 NA

NIS-2 (Back)

Sheet 2 of 2 Date: 11/16/2001 Name of Component:

FDW-H39 Work Order Number: 01-018044 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed Y g%/e, /1kA/1A41WJ5KZ1 MAMA owrj Looj&ýDate 20 OX I Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-2y-i" to /- 31-OZ, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions

NB7741, I, N, IS, A WIS 100024 Inspector's S;(nature National Board, State, Province, and Endorsements Date-e

/

,20 D

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 05B Class 2

AUXILIARY FEEDWATER

5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component FDW-H43 Name of Manufacturer ITT GRINNEL COMPANY Manufacturer Serial No.

NA National Board No.

NA NA 1967 KHAlU I"

Other ID Date 11/15/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-018044 Type Code Sym. Stamp NA.

Authorization No. NA Expiration Date NA Code Case NA Year Built

Repaired, ASM E
Repaired, Replaced, or Replacement
7. Description of Work REPAIR CLASS 2 AUXILAIRY FEEDWATER SYSTEM 3" HANGER FDW-H43 DUE TO LOOSE NUT ON THE PIPE CLAMP.
8. Tests conducted Hydrostatic

]

Other [

Pneumatic Li Pressure Nominal Operating Pressure psi Test Temp.

n Exempt r*

deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped REPAIRED IN NA 1967 NA

NIS-2 (Back)

Sheet 2 of 2 Date: 11/15/2001 Name of Component:

FDW-H43 Work Order Number: 01-018044 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed Date__

_2Dat 2

tQ Owner or Owner's Designee, Title U

Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period

'7-o.rOe to 1-3t-OZ, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions

NB7741, I, N, IS, A WIS 100024 Inspector Signature National Board, State, Province, and Endorsements Date

/

20 0 L"

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section X1

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 05B Class 2 AUXILIARY FEEDWATER
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component FDW-H44 Name of Manufacturer ITT GRINNEL COMPANY Manufacturer Serial No.

NA National Board No.

NA Other ID NA Date 11/16/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-018044 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA Year Built 1967

Repaired, ASME
Repaired, Replaced, or Replacement REPAIRED
7. Description of Work REPAIR CLASS 2 AUXILAIRY FEEDWATER SYSTEM 3" HANGER FDW-H44 DUE TO LOOSE NUT ON THE PIPE CLAMP.
8. Tests conducted Hydrostatic Other D Pneumatic Pressure Nominal Operating Pressure psi Test Temp.

0l deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped N

Exempt El N

NIS-2 (Back)

Sheet 2 of 2 Date: 11/16/2001 Name of Component:

FDW-H44 Work Order Number: 01-018044 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed Iý

?,-

Date**".i~at*-/--'4*P (0.l~'l4/

Dh6t4

,20 OcL Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period '7--F-7 to /

,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

  • 4, Commissions NB7741, I, N, IS, A WIS 100024 nspector's Signa ure National Board, State, Province, and Endorsements Date

/

20

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corooration 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 89A Class MC BUILDINGS - STRUCTURES
5. (a) Applicable Construction Code SEC. Il-CL.B-1965W (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 ADDENDA
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component RBCV Name of Manufacturer CHICAGO BRIDGE AND IRON Manufacturer Serial No.

C4454 National Board No.

NA Other ID 1S-0002 Date 11/24/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-018045 Type Code Sym. Stamp N.*A Authorization No.

NA Expiration Date NA Code Case NA Year Built 1969

Repaired, Replaced, or Replacement REPAIRED
7. Description of Work REPAIR CLASS MC (METAL CONTAINMENT) REACTOR BUILDING CONTAINMENT VESSEL MOISTURE BARRIER BONDING BETWEEN ELEVATION 606' AND METAL CONTAINMENT.
8. Tests conducted Hydrostatic Other 1

Dl Pneumatic Pressure D-Nominal Operating Pressure psi Test Temp.

Exempt Li deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped Y

NIS-2 (Back)

Sheet 2 of 2 Date: 11/24/2001 Name of Component:

RBCV Work Order Number: 01-018045 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed.20 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period T'7-Ar'-

to /-31-03-,

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 nspector's nature National Board, State, Province, and Endorsements Date

/

,20 D,..

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 33 Class 1 SAFETY INJECTION
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component S1-13B Name of Manufacturer VELAN VALVE CORPORATION Manufacturer Serial No.

NF National Board No.

NA Other ID S1116-002 1967 RPLACMN I

N Date 12/1/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-018277 Type Code Sym. Stamp NA Authorization No.

NA Expiration Date NA Code Case NA Year Built Ipiru, P.IVIE

Repaired, Replaced, or Replacement
7. Description of Work REPAIR CLASS 1 6" SAFETY INJECTION SYSTEM VALVE SI-13B DUE TO 4 PIN HOLE LEAKS IN THE SEAL WELD INCLUDING REPLACING 4 STUDS.
8. Tests conducted Hydrostatic El Other D]

Pneumatic Pressure 2240 psi Nominal Operating Pressure Test Temp.

f55 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached Code Stamped Exempt F

REPLACEMENT N

1967 S1 116-002

NIS-2 (Back)

Sheet 2 of 2 Date:

12/1/2001 Name of Component:

S1-13B Work Order Number: 01-018277 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section Xl.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed

&UN44

  • d w

Date L 20 Q Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-15r-,90' to /-

3 /-,

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I1 N, IS, A WIS 100024 Inspector's ignature National Board, State, Province, and Endorsements Date

/

,20 0,__

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street. Hudson, Wisconsin 54016
4. Identification of System 89A Class MC BUILDINGS - STRUCTURES
5. (a) Applicable Construction Code SEC. III-CL.B-1965W (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 ADDENDA
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component EMRG.

AIRLOCK Name of Manufacturer CHICAGO BRIDGE AND IRON Manufacturer Serial No.

C4454 National Board No.

NA 1S-0002 1969 t.MAI tU I

Other ID Date 11/21/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-018283 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA Year Built

Repaired, ASME
Repaired, Replaced, or Replacement
7. Description of Work REPAIR CLASS MC METAL CONATINMENT EMERGENCY AIRLOCK DUE TO BOLT NOT FLUSH WITH SURFACE.
8. Tests conducted Hydrostatic Other F"

El Pneumatic Pressure R7 psi Nominal Operating Pressure Test Temp.

Exempt Li deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped REPAIRED

,f 1S-0002 1969 NA

NIS-2 (Back)

Sheet 2 of 2 Date: 11/21/2001 Name of Component:

EMRG. AIRLOCK Work Order Number: 01-018283 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed *

    • 1 Date -

,20 Oý Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-23-'o to

-3/-,2., and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

7ýý

.-,Commissions NB7741, 1, N, IS, A WIS 100024 pector's Si" ature National Board, State, Province, and Endorsements Date 1"-

.20 __

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 33 Class 1 SAFETY INJECTION
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component S1-13B Name of Manufacturer VELAN VALVE CORPORATION Manufacturer Serial No.

NF National Board No.

NA Other ID S1116-002 Date 12/1/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-018402 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA Year Built 1967 REPAIRED N

Repaired, ASME
Repaired, Replaced, or Replacement
7. Description of Work REMOVE GOUGES AND PREPARE GASKET SURFACE OF CLASS 1 SAFETY INJECTION SYSTEM 6" VALVE SI 13B BONNET SURFACE.
8. Tests conducted Hydrostatic Other j

Pneumatic El Pressure 2240 psi Nominal Operating Pressure Test Temp.

551 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped Exempt REPAIRED N

1967

NIS-2 (Back)

Sheet 2 of 2 Date:

12/1/2001 Name of Component:

SI-13B Work Order Number: 01-018402 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed Owwvf Date

.20 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period "7-21o-ap to __3_-9__

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, 1, N, IS, A WIS 100024 Inspectors ignature National Board, State, Province, and Endorsements Da tee 20 99,A

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 34 Class 2 RESIDUAL HEAT REMOVAL
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Manufacturer ITT GRINNELL VALVE COMPANY Manufacturer Serial No.

NA National Board No.

NA Other ID NA Date 11/26/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-018522 Type Code Sym. Stamp NA.

Authorization No. NA Expiration Date NA Code Case NNA Year Built 1967 REPAIRED N

Hepaired, AML
Repaired, Replaced, or Replacement
7. Description of Work REPAIR CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM 8" HANGER RHR-H18 DUE TO LOAD SETTING OF SCALE.
8. Tests conducted Hydrostatic Other n

Pneumatic Pressure Nominal Operating Pressure psi Test Temp.

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached Name of Component RHR-H18 ASME Code Stamped D:

deg. F Exempt El REPAIRED IN 1967

NIS-2 (Back)

Sheet 2 of 2 Date: 11/26/2001 Name of Component:

RHR-H18 Work Order Number: 01-018522 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed P eOU Date 20 0 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-0.S'- C.V to ________

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

,1

-ý7ý Commissions NB7741, I, N, IS, A WIS 100024 National Board, State, Province, and Endorsements

-- lnspector's S(nature Date-

,'/

,20 9 5L a7

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 34 Class 2 RESIDUAL HEAT REMOVAL
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component RHR-H24 Name of Manufacturer ITT GRINNELL VALVE COMPANY Manufacturer Serial No.

NA National Board No.

NA Other ID NA 1967 REPAIRED N

Date 11/26/2001 Sheet I of 2 Unit No. 1 Work Order 01-018522 Type Code Sym. Stamp N__A Authorization No.

NA Expiration Date NA Code Case NA Year Built

Kepalreo, AM 
Repaired, Replaced, or Replacement
7. Description of Work REPAIR CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM 8" HANGER RHR-H24 DUE TO MISALIGNMENT OF SUPPORT.
8. Tests conducted Hydrostatic Other F]

Pneumatic F1 Pressure Nominal Operating Pressure psi Test Temp.

D:

deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached Code Stamped Exempt E

REPAIRED N

NA 1967

NIS-2 (Back)

Sheet 2 of 2 Date: 11/26/2001 Name of Component:

RHR-H24 Work Order Number: 01-018522 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed Date 20 0.1 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-,Sr-6' to /-

.3/'-OZ, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

nsp C

.Commissions

NB7741, I, N, IS, A WIS 100024 nspector's Sig re National Board, State, Province, and Endorsements Da ate7* *4 20 0

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 33 Class 1

SAFETY INJECTION

5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component RSI-H7 Name of Manufacturer ITT GRINNELL VALVE CO.

Manufacturer Serial No.

NA National Board No.

NA Other ID NA 1967 REPAIRED N

Date 11/26/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-018525 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA Year Built

Repaired, ASME
Repaired, Replaced, or Replacement
7. Description of Work REPAIR CLASS 1 SAFETY INJECTION SYSTEM 2" SUPPORT RSI-H7 DUE TO DAMAGED SPRING CAN.
8. Tests conducted Hydrostatic

[]

Other F

Pneumatic R Pressure Nominal Operating Pressure psi Test Temp.

D3 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped Exempt 17 REPAIRED N

1967 NA

NIS-2 (Back)

Sheet 2 of 2 Date: 11/26/2001 Name of Component:

RSI-H7 Work Order Number: 01-018525 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed

/4.,6 t

I.TIVA*OffN

,O"m,. Date JA,20

_.L_

Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period I.- 29.'-P to /- 3/-0 ZI., and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

9 sp tCommissions NB7741, I, N, IS, A WIS 100024 ospector's SiLgature National Board, State, Province, and Endorsements Date 20 01:4-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street. Hudson, Wisconsin 54016
4. Identification of System 34 Class 2 RESIDUAL HEAT REMOVAL
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component RHR-3B Name of Manufacturer CRANE COMPANY Manufacturer Serial No.

NF National Board No.

NA Date 12/19/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-018670 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA Other Year ID Built AC034-002 1972 REPAIRED N

ICepaireu, MIVI

R~epaired, Replaced, or Replacement

7. Description of Work REPAIR BONNET TO BODY LEAK BY TORQUING BOLTING ON CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM 8" VALVE RHR-3B.
8. Tests conducted Hydrostatic Other D R

Pneumatic Pressure D

Nominal Operating Pressure psi Test Temp.

E]

deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturers Data Reports to be Attached Code Stamped Exempt F*

REPAIRED N

AC034-002 1972

NIS-2 (Back)

Sheet 2 of 2 Date: 12/19/2001 Name of Component:

RHR-3B Work Order Number: 01-018670 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed (O

Date 20 Q2 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-;r-00 to I/-3zNC

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions

NB7741, I, N, IS, A WIS 100024 Inspecors naNational Board, State, Province, and Endorsements Date d,

,/

,20 O,-P

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 33 Class 2 SAFETY INJECTION
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component SI-9B Name of Manufacturer VELAN VALVE CORPORATION Manufacturer Serial No.

NA National Board No.

NA Other ID S1012-002 Date 12/1/2001 Sheet 1 of 2 Unit No. 1 Work Order 97-212982 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA Year Built 1967

Repaired, Replaced, or Replacement REPAIRED
7. Description of Work OPEN FOR REPACKING CLASS 2 SAFETY INJECTION SYSTEM 3" VALVE SI-9B.
8. Tests conducted Hydrostatic F]

Other n

Pneumatic F

Nominal Operating Pressure r

Pressure 2190 psi Test Temp.

551 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturers Data Reports to be Attached ASME Code Stamped N

Exempt 1 N

NIS-2 (Back)

Sheet 2 of 2 Date:.

12/1/2001 Name of Component:

SI-9B Work Order Number: 97-212982 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed 7&ifL 4c A

C L

ft**

L4A, v,

Date te kLM4AMJ 20 0_.

Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period -I-2r-,O9 to b

}-.,,,

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

X

.Commissions NB7741, I, N, IS, A WIS 100024

(--ýpectors Sign ure National Board, State, Province, and Endorsements Date

/

,20 0

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 36 Class 1 REACTOR COOLANT
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component LD-3 Name of Manufacturer MASONEILAN INTERNATIONAL Manufacturer Serial No.

H46695-1-2 National Board No.

NA Date 12/3/2001 Sheet 1 of 2 Unit No. 1 Work Order 00-003219 Type Code Sym. Stamp NA Authorization No. INA Expiration Date NA Code Case NA Other Year ID Built RC011-002 1970

Repaired, ASME
Repaired, Replaced, or Replacement REPLACED N
7. Description of Work DISASSEMBLE AND INSPECT CLASS 1 REACTOR COOLANT SYSTEM 2" VALVE LD-3 AND REPLACE 8 STUDS AND 8 NUTS.
8. Tests conducted Hydrostatic F]

Other F]

Pneumatic n

Nominal Operating Pressure E'

Pressure 2240 psi Test Temp.

551 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped Exempt El REPLACED N

NIS-2 (Back)

Sheet 2 of 2 Date:

12/3/2001 Name of Component:

LD-3 Work Order Number: 00-003219 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACED conforms to the rules of the ASME Code Section Xl.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Date 20 0=1 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period

,1-5-O 0 to /-3-bZ, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 4/setors Sign6(ure National Board, State, Province, and Endorsements Date 1'

20 T,

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corooration 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 05A Class 2 FEEDWATER
5. (a) Applicable Construction Code NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component SG-AH-1 Name of Manufacturer MCDOWELL WELLMAN Manufacturer Serial No.

25.12620.004-1 National Board No.

NA Other ID 1S-0066 Date 12/3/2001 Sheet 1 of 2 Unit No. 1 Work Order 00-004319 Type Code Sym. Stamp NA Authorization No.

NA Expiration Date NA Code Case NA Year Built 1971

Repaired, Replaced, or Replacement REPLACEMENT
7. Description of Work REBUILD 900 KIP HYDRAULIC SNUBBER ON CLASS 2 MAIN STEAM AND STEAM DUMP SYSTEM STEAM GENEARTOR IA.
8. Tests conducted Hydrostatic Other L]

-l Pneumatic Pressure

-1D Nominal Operating Pressure psi Test Temp.

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped N

D:

deg. F Exempt FR

NIS-2 (Back)

Sheet 2 of 2 Date:

12/3/2001 Name of Component:

SG-AH-1 Work Order Number: 00-004319 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed "9LAdJ

ZM5dAA,

&ti-L" Owner or Owner's Designee, Title Date 20 0,;0 Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 745r-',

to /--,/I-Z

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, 1, N, IS, A WIS 100024 Inspector's S~i ature National Board, State, Province, and Endorsements Date 6A"*

/

20 0,7 0

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 05A Class 2 FEEDWATER
5. (a) Applicable Construction Code NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component Name of Manufacturer Manufacturer Serial No.

National Board No.

Other ID Date 12/3/2001 Sheet 1 of 2 Unit No. 1 Work Order 00-004319 Type Code Sym. Stamp NA Authorization No.

NA Expiration Date NA Code Case NA Year Built

Repaired, ASME
Repaired, Replaced, or Replacement 25.12620.004-7 NA 1S-0066 1971 REPLACEMENT N
7. Description of Work REBUILD 900 KIP HYDRAULIC SNUBBER ON CLASS 2 MAIN STEAM AND STEAM DUMP SYSTEM STEAM GENERATOR lB.
8. Tests conducted Hydrostatic El Other r--

Pneumatic Pressure El Nominal Operating Pressure psi Test Temp.

Exempt 17 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached SG-AH-2 MCDOWELL WELLMAN ASME Code Stamped REPLACEMENT N

NIS-2 (Back)

Sheet 2 of 2 Date:

12/3/2001 Name of Component:

SG-AH-2 Work Order Number: 00-004319 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed ewr-m-LO1 f,

Date

,20 0 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 17

-0O to /- J/o-02, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, 1, N, IS, A WIS 100024 Unspector's Siglature National Board, State, Province, and Endorsements Date

.20

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street. Hudson, Wisconsin 54016
4. Identification of System 35 Class 2 CHEMICAL AND VOLUME CONTROL
5. (a) Applicable Construction Code NA (b) Applicable Edition of Section X1 Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Manufacturer AJAX IRON WORKS Manufacturer Serial No.

6576 National Board No.

NA Other ID 00076 Date 2/26/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-001998 Type Code Sym. Stamp NA Authorization No.

NA Expiration Date NA Code Case NA Year Built 1967

Repaired, Replaced, or Replacement REPAIRED
7. Description of Work REPAIR CLASS 2 CHEMICAL AND VOLUME CONTROL SYSTEM CHARGING PUMP 1B SUCTION VALVE.
8. Tests conducted Hydrostatic Other D E-Pneumatic 1

Nominal Operating Pressure El Pressure 26 psi Test Temp.

115 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached Name of Component APCH-11B ASME Code Stamped N

Exempt 1:]

NIS-2 (Back)

Sheet 2 of 2 Date:

2/26/2001 Name of Component:

APCH-1 B Work Order Number: 01-001998 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed k

&*SaNdUft4U Date 200 ;6 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 1-7-r-00 to 1-3/1-2

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspector's Si ature National Board, State, Province, and Endorsements Date a20 0 ;t-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 36 Class 1 REACTOR COOLANT
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Manufacturer PCIENERGY SERVICES Manufacturer Serial No.

110/1M National Board No.

NA Other ID NA Date 12/3/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-002115 Type Code Sym. Stamp NA Authorization No.

NA Expiration Date NA Code Case N-416-2 Year Built 2001

Repaired, Replaced, or Replacement REPLACED
7. Description of Work REPLACED WELD FOR CLASS 1 REACTOR COOLANT SYSTEM STEAM GENERATOR 1A NOZZLE TO SAFE END WELD
8. Tests conducted Hydrostatic Other r-Pneumatic r-Pressure 2240 psi Nominal Operating Pressure r7 Test Temp.

551 deg. F Applicable Manufacturer's Data Reports to be Attached Name of Component RC-W76DM ASME Code Stamped N

Exempt 11

9. Remarks UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SECTION XI: CODE CASE N-416-2 PER NRC APPROVAL OF RELIEF REQUEST RR-G-4.

NIS-2 (Back)

Sheet 2 of 2 Date:

  • 12/3/2001 Name of Component:

RC-W76DM Work Order Number: 01-002115 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed

&4,0~

7eýP 04&

-0M-Owner or Owner's Designee, Title Date 20 0 Certificate of INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period *1,2f-l to /- 3/1#2.., and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4 lns c7

&Commissions NB7741, I, N, IS, A WIS 100024 Inspector's Si National Board, State, Province, and Endorsements Date f I

,20 0

Z

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 36 Class 1 REACTOR COOLANT
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Manufacturer PCI ENERGY SERVICES Manufacturer Serial No.

NA National Board No.

NA Other ID NA Date 12/3/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-002115 Type Code Sym. Stamp NA Authorization No.

NA Expiration Date NA Code Case N-416-2 Year Built 2001

Repaired, Replaced, or Replacement REPLACED
7. Description of Work REPLACED WELD FOR CLASS 1 REACTOR COOLANT SYSTEM STEAM GENERATOR 1A NOZZLE TO SAFE END.
8. Tests conducted Hydrostatic El Other D Pneumatic Nominal Operating Pressure Pressure 2240 psi Test Temp.

551 deg. F Applicable Manufacturer's Data Reports to be Attached Name of Component RC-W77DM ASME Code Stamped N

Exempt 1

9. Remarks UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SECTION XI: CODE CASE N-416-2 PER NRC APPROVAL OF RELIEF REQUEST RR-G-2.

NIS-2 (Back)

Sheet 2 of 2 Date:

12/3/2001 Name of Component:

RC-W77DM Work Order Number: 01-002115 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed

&14" Date 4

20 oA Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-4U'-00 to /°.3 I'V2, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 nspector's Sigrature National Board, State, Province, and Endorsements Date 20 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson. Wisconsin 54016
4. Identification of System 36 Class 1 REACTOR COOLANT
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component RC-W78DM Name of Manufacturer PCIENERGY SERVICES Manufacturer Serial No.

110/2 National Board No.

NA Other ID NA Date 12/3/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-002115 Type Code Sym. Stamp NA Authorization No.

NA Expiration Date NA Code Case N-416-2 Year Built 2001

Repaired, ASM
Repaired, Replaced, or Replacement REPLACED N
7. Description of Work REPLACED WELD FOR CLASS 1 REACTOR COOLANT SYTEM STEAM GENERATOR 1B NOZZLE TO SAFE END WELD.
8. Tests conducted Hydrostatic Other D Pneumatic F

Pressure 2240 psi Nominal Operating Pressure L

Test Temp.

55_1 deg. F

9. Remarks UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SECTION XI: CODE CASE N-416-2 PER NRC APPROVAL OF RELIEF REQUEST RR-G-4.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped Exempt REPLACED N

NIS-2 (Back)

Sheet 2 of 2 Date:.

12/3/2001 Name of Component:

RC-W78DM Work Order Number: 01-002115 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed R

lOr.

Date,n 4

20 0.

Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period __-_______

to /- 31-07-, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, 1, N, IS, A WIS 100024 Inspectors,nature National Board, State, Province, and Endorsements Date.

/

,20 *-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Manaqement Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 36 Class 1 REACTOR COOLANT
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component RC-W79DM Name of Manufacturer PCIENERGY SERVICES Manufacturer Serial No.

110/1 National Board No.

NA Other ID NA Date 12/3/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-002115 Type Code Sym. Stamp N.AA Authorization No.

NA Expiration Date NA Code Case N-416-2 Year Built 2001

Repaired, Replaced, or Replacement REPLACED
7. Description of Work REPLACED WELD FOR CLASS 1 REACTOR COOLANT SYSTEM STEAM GENERATOR 1B NOZZLE TO SAFE END.
8. Tests conducted Hydrostatic Other D rF Pneumatic F

Nominal Operating Pressure E

Pressure 2240 psi Test Temp.

551 deg. F Exempt 1

9. Remarks UTILIZATION OF ASME BOILER AND PRESSURE VESSEL CODE SECTION XI: CODE CASE N-416-2 PER NRC APPROVAL OF RELIEF REQUEST RR-G-4.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped N

NIS-2 (Back)

Sheet 2 of 2 Date:.

12/3/2001 Name of Component:

RC-W79DM Work Order Number: 01-002115 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed I1IWA W

&OnL~n dUM" Date 20 01 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 72 to,/-3/-,

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, 1, N, IS, A WIS 100024 rInspector's Si ature National Board, State, Province, and Endorsements Date 20 D

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 34 Class 2 RESIDUAL HEAT REMOVAL
5. (a) Applicable Construction Code SECTION III CLASS 2 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Date 12/11/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-003411 Type Code Sym. Stamp NA Authorization No.

NA Expiration Date NA Code Case NA

Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No.

Board No.

ID Built Replacement Stamped RHR-33-1 CROSBY VALVE AND GAGE N62651-00-0001 NA ACl 15-001 1978 REPAIRED N

COMPANY

7. Description of Work REMOVE FOR TESTING CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM 4" VALVE RHR-33-1.
8. Tests conducted Hydrostatic Other F

EI Pneumatic 1"1 Nominal Operating Pressure El Pressure 150 psi Test Temp.

60 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached Exempt 1

NIS-2 (Back)

Sheet 2 of 2 Date:

12/1/2001 Name of Component:

RHR-33-1 Work Order Number: 01-003411 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed

&V4ii CA194 Date 1-1 -20 Q

Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 97I,.-v, to /-3/- 0 Z., and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

24,Commissions NB7741, 1, N, IS, A WIS 100024 lnspector'sSiaature National Board, State, Province, and Endorsements Date

,C

/

20 0

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section X1

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 34 Class 2 RESIDUAL HEAT REMOVAL
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Manufacturer CROSBY ASHTON GAGE COMPANY Manufacturer Serial No.

NF National Board No.

NA Date 12/1/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-003412 Type Code Sym. Stamp N..A Authorization No.

NA Expiration Date NA Code Case NA Other Year ID Built AC107-001 1971

Repaired, Replaced, or Replacement REPAIRED
7. Description of Work REMOVE FOR TESTING CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM 2" VALVE RHR-33.
8. Tests conducted Hydrostatic

[]

Other n

Pneumatic Nominal Operating Pressure Pressure 150 psi Test Temp.

60 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached Name of Component RHR-33 ASME Code Stamped N

Exempt 1

NIS-2 (Back)

Sheet 2 of 2 Date:.

12/1/2001 Name of Component:

RHR-33 Work Order Number: 01-003412 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed If-.A 4eI4A.,

L Date q

1

,20 O.1 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period ?7-2,r-a to/- 3/-# 2-, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

SCommissions NB7741,, N, IS, A WIS 100024 Inspector's Sigjture National Board, State, Province, and Endorsements Date

,20 9'9;-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street. Hudson, Wisconsin 54016
4. Identification of System 23 Class 2 CONTAINMENT SPRAY
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Manufacturer WILLIAM POWELL CO.

Manufacturer Serial No.

NF National Board No.

NA Date 11/26/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-004985 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA Other Year ID Built ICS022-001 1968

Repaired, ASME
Repaired, Replaced, or Replacement REPAIRED N
7. Description of Work OPEN FOR INSPECTION CLASS 2 CONTAINMENT SPRAY 2" VALVE Cl-1003.
8. Tests conducted Hydrostatic Other F

Pneumatic F]

Pressure 31 psi Nominal Operating Pressure M

Test Temp.

69.6 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached Name of Component Cl-1003 ASME Code Stamped Exempt 1 REPAIRED N

NIS-2 (Back)

Sheet 2 of 2 Date:.11/26/2001 Name of Component:

C1-1003 Work Order Number: 01-004985 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed a e

&.a 4..'2%,

AoLv

,.lý c

4 Date 6uomi 20 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period Y-Ar-a to

-3d JJ-,

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

&ýý "=

-1,.,.*Commissions NB7741, I, N, IS, A WIS 100024 Inspector's jgnature National Board, State, Province, and Endorsements Date

/

,20

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 33 Class 1 SAFETY INJECTION
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Manufacturer ANCHOR/DARLING ENTERPRISES Manufacturer Serial No.

11542-13 National Board No.

NA Other ID SIl15-003 Date 12/3/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-005010 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA Year Built 1970

Repaired, Replaced, or Replacement REPAIRED
7. Description of Work OPEN FOR INSPECTION CLASS 1 SAFETY INJECTION SYSTEM 12" VALVE SI-21A.
8. Tests conducted Hydrostatic Other F

Pneumatic Pressure 2240 psi Nominal Operating Pressure Test Temp.

551 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached Name of Component SI-21A ASME Code Stamped N

Exempt 1--

NIS-2 (Back)

Sheet 2 of 2 Date:.

12/3/2001 Name of Component:

SI-21A Work Order Number: 01-005010 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed

'e*

-L'-*4 0,X A

Date 20 Q, 1 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 1

,-Knev to

-,,31/'2, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

lnp

,Commissions NB7741, I, N, IS, A WIS 100024 Inspector'si ature National Board, State, Province, and Endorsements Date

4

,20 Z

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 33 Class 1 SAFETY INJECTION
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section X1 Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Manufacturer Manufacturer Serial No.

ANCHOR/DARLING VALVE NF COMPANY National Board No.

NA Other ID S1115-004 Date 12/3/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-005011 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA Year Built 1970

Repaired, Replaced, or Replacement REPAIRED
7. Description of Work OPEN FOR INSPECTION CLASS 1 SAFETY INJECTION SYSTEM 12" VALVE SI-21B.
8. Tests conducted Hydrostatic Other Dl F

Pneumatic r-1 Nominal Operating Pressure El Pressure 2240 psi Test Temp.

a55 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached Name of Component SI-21 B ASME Code Stamped N

Exempt 1]

NIS-2 (Back)

Sheet 2 of 2 Date:

12/3/2001 Name of Component:

SI-21B Work Order Number: 01-005011 Date

/

20 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed I4.*,

Date.

,4gADt 20 OZ Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period __-2___O' to 14/4O2-, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

ý_

-Commissions NB7741, 1, N, IS, A WIS 100024 National Board, State, Province, and Endorsements

_.Inspector's Signature

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 33 Class 1 SAFETY INJECTION
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Manufacturer ANCHOR/DARLING ENTERPRISES Manufacturer Serial No.

NF National Board No.

NA Other ID S1115-001 Date 11/26/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-005012 Type Code Sym. Stamp N._A Authorization No.

NA Expiration Date NA Code Case NA Year Built 1970

Repaired, Replaced, or Replacement REPAIRED
7. Description of Work OPEN FOR INSPECTION CLASS 1 SAFETY INJECTION SYSTEM 12" VALVE SI-22A.
8. Tests conducted Hydrostatic Other F

Pneumatic F

Pressure 750 psi Nominal Operating Pressure

=.

Test Temp.

63 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached Name of Component SI-22A ASME Code Stamped N

Exempt 1"-

NIS-2 (Back)

Sheet 2 of 2 Date:.11/26/2001 Name of Component:

SI-22A Work Order Number: 01-005012 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed LJ6

  • 0
  • ..IW

.A fPA"?1 l'1, Date 20 0-1 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the pedod _'__"__

to /-3/"6-a, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

SCommissions NB7741, I, N, IS, A WIS 100024 Inspector's nature National Board, State, Province, and Endorsements Date 2

,20 9

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation 700 North Adams P.O. Box 19001 Green Bay, WI 54307-9001
2. Plant: Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee WI 54216-9511 Date: 12/12/01 Sheet: 1 of 3 Unit: No.1 Work Order#: SEE BELOW WORK ORDER WP&IR DESCRIPTION 01-007152 M-FCU-385 REMOVE AND RECONNECT SW PIPING TO CFCU'S Work Performed by: Bechtel Construction Identification of System:

02 Class:

3 Name: SERVICE WATER (a) Applicable Construction Code: USAS B31.1, 1967 Ed., No Add.

C (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add.

C Identification of Components Repaired or Replaced and Replacement Components:

ode Case: N/A ode Case: N/A Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial No.

Board Identification Built

Replaced, Code No.

or Stamped Replacement Yes/No See continuation sheet, page 3

7. Description of Work: REMOVE AND REINSTALL SERVICE WATER SYSTEM CONTAINMENT COOLING CONTAINMENT FAN COIL UNITS C AND D AND ASSOCIATED SERVICE WATER LINES
8. Tests Conducted:

Hydrostatic E] Pneumatic [j Nominal Operating Pressure Z Exempt E]

Other: El Pressure: 92 psi Test Temp: 44.2 0F Page 1 of`3

3.
4.

5.

6.

Date: 12/12/01 Name of Component: SERVICE WATER Work Order Number: 01-007152 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period 0

-Uf to I

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward)_

Commissions

' I(*A4 Inspector's Signature National Board, State, Province, and Endorsements Date:

/a-/*-

2001 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Page 2 of 3 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code,Section XI repair or replacement.

Type Code Symbol Stamp Certificate of Authorization No.

N/A Expiration Date N/A Signed:

Date/--Date Owner or Owner's Designee, Title N/A

Continuation Sheet Name of Component SERVICE WATER Work Order Number: 01-007152 Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No CFCU C INLET N/A N/A N/A N/A N/A REPAIRED NO PIPING CFCU C OUTLET N/A N/A N/A N/A N/A REPAIRED NO PIPING CFCU D INLET N/A N/A N/A N/A N/A REPAIRED NO PIPING CFCU D OUTLET N/A N/A N/A N/A N/A REPAIRED NO PIPING 5/8" BOLTS MACKSON N/A N/A HT USY87951 N/A REPLACEMENT NO 5/8" NUT MACKSON N/A N/A HT 7307732 N/A REPLACEMENT NO 5/8" STUD MACKSON N/A N/A HT M60635 N/A REPLACEMENT NO t

t

-t 1

1 t

-

I I

t I*

+/-

I I

f

+

I 1

+

I I

1-Page 3 of 3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation 700 North Adams P.O. Box 19001 Green Bay, WI 54307-9001
2. Plant: Kewaunee Nuclear Power Plant N490 HWY 42 Kt.w*Ni*e WI 54216-9511 Date: 12/12/01 Sheet: 1 of 5 Unit : No.1 Work Order#: SEE BELOW WORK ORDER WP&IR DESCRIPTION 01-008137 M-ULR-311 Remove & Modify Upper Lateral Work Performed by: Bechtel Construction Identification of System:

05A Class:

2 Name: "A" Upper Lateral inclu' Snubber (a) Applicable Construction Code: USAS B31.1, 1967 Ed., No Add.

(b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989, No Add.

Identification of Components Repaired or Replaced and Replacement Components:

ding Spring Cans &

Code Case: N/A Code Case: N/A Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial No.

Board Identification Built

Replaced, Code No.

or Stamped Replacement Yes/No See continuation sheet, page 3

8. Description of Work: Repaired Upper Lateral Restraint and replacement of bolting and shims for upper lateral
9. Tests Conducted:

Hydrostatic [] Pneumatic []

Nominal Operating Pressure F1 Exempt 0 Other: r]

Pressure:

psi Test Temp

-F Page 1 of 5

3.
4.
5.
6.

7.

Date: 12/12/01 Name of Component: UPPER LATERAL RESTRAINT SYSTEM.

Work Order Number: 01-008137 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code,Section XI repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed:

Yi, c -,:4-.e,Sv,-

Date -!

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period n9-/1?2*!

to [t-,oci

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward)

Commissions t,* a 3

SS*"-i)A-;

PYft lnspeot6Fýs Signature/

National Board, State, Province, and Endorsements Date:

r -/%

20 cý Page 2 of 5

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No "A" Hydraulic McDowell 25.12620.004-1 N/A IS-0066 1971 Repaired No Snubber Wellman "A" Upper Lateral N/A N/A N/A N/A N/A Repaired No Ring Girder Splice Plate, Ring Colonial Ht. No. 412H07 N/A N/A 2001 Replacement No Girder, ASTM A588, Gr. A Splice Plate Bolt, Colonial HT No. 10187-N/A N/A 2001 Replacement No ASTM A540, RYE Gr.B23, Cl. 2 Splice Plate Heavy Colonial Ht. No. 8994464 N/A N/A 2001 Replacement No Hex. Nuts, A194, Trace Code SBG Gr. 2H Splice Plate Colonial Ht. No. Y85307 N/A N/A 2001 Replacement No Washers, F436 Trace Code SBH Splice Plate Heavy Colonial Ht. No. S42483 N/A N/A 2001 Replacement No Hex Nuts, A 194, Trace Code I UV Gr. 2H Bumper Plate, A588 Colonial Ht. No. BI S6214 N/A N/A 2001 Replacement No GR A Side Bumper Colonial Ht. No. l B518 N/A N/A 2001 Replacement No Bearing Plate, A588 3" Threaded Rod, Colonial Ht. No. 8991820 N/A N/A 2001 Replacement No A540 Gr. B23, Cl. 2 V" Hex. Nut, A563 Colonial Ht. No. 34467PJ N/A N/A 2001 Replacement No Washer, F436 Colonial Ht. No. 107494 N/A N/A 2001 Replacement No Side Bumper Shim, Colonial Ht. No. EIF023-N/A N/A 2001 Replacement No A36 A12 Side Bumper Shim, Colonial Ht. No. E1GI 19-N/A N/A 2001 Replacement No A36 A16 Side Bumper Shim, Colonial Ht. No. EIG 119-N/A N/A 2001 Replacement No A36 A16 Side Bumper Shim, Colonial Ht. No. B1F669-N/A N/A 2001 Replacement No A36 C16 Side Bumper Shim, Colonial Ht. No. T2866 N/A N/A 2001 Replacement No A36 Side Bumper Shim, Colonial Ht. No. A1C202-N/A N/A 2001 Replacement No A36 B20 Side Bumper Shim, Colonial Ht. No. A1D370-N/A N/A 2001 Replacement No A36 B32 Side Bumper Shim, Colonial Ht. No. B1E825-N/A N/A 2001 Replacement No A36 B16 Side Bumper Shim, Colonial Ht. No. B11F555-N/A N/A 2001 Replacement No A36 C23 Side Bumper Shim, Colonial Ht. No. 64595 N/A N/A 2001 Replacement No A109 CI010 Side Bumper Shim, Colonial Ht. No. Y07405 N/A N/A 2001 Replacement No A109 CI010 Side Bumper Shim, Colonial Ht. No. 65747 N/A N/A 2001 Replacement No A109 CI010 Side Bumper Shim, Colonial Ht. No. M06708 N/A N/A 2001 Replacement No A109 CI010 Upper Lateral Ring Colonial Ht. No.

N/A N/A 2001 Replacement No Plate, A36 A1T128'3 3/8" Threaded Rod, Colonial Ht. No. 813953 N/A N/A 2001 Replacement No A307, Gr. A Page 3 of 5

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No Heavy Hex Nuts, Colonial Ht. No. A61415 N/A N/A 2001 Replacement No A563, Gr. A Std. Washer, F436, Colonial Ht. No. B16294 N/A N/A 2001 Replacement No Type 1 Upper Lateral Ring Colonial Ht. No. A1U1599 N/A N/A 2001 Replacement No Plate Shim, A36 Upper Lateral Ring Colonial Ht. No. BIP5527 N/A N/A 2001 Replacement No Plate Shim, A36 Upper Lateral Ring Colonial Ht. No AOR0914 N/A N/A 2001 Replacement No Plate Shim, A36 Upper Lateral Ring Colonial Ht. No 7467439 N/A N/A 2001 Replacement No Plate Shim, A36 Upper Lateral Ring Colonial Ht. No 1A353 N/A N/A 2001 Replacement No Plate Shim, A36 3/8" Hex Hd. Bolt, Colonial Ht. No. 8878678 N/A N/A 2001 Replacement No A307-97 3/8" Std. Washer, Colonial Ht. No. B 16294 N/A N/A 2001 Replacement No F436 Type I Ring Girder Shim, Colonial Ht. No. 1E479 N/A N/A 2001 Replacement No A36 Ring Girder Shim, Colonial Ht. No. 1E744-A N/A N/A 2001 Replacement No A36 Ring Girder Shim, Colonial Ht. No. 2A6386-N/A N/A 2001 Replacement No A36 C

Ring Girder Shim, Colonial Ht. No. 2A6593-N/A N/A 2001 Replacement No A36 C

Ring Girder Shim, Colonial Ht. No. 4151614 N/A N/A 2001 Replacement No A109-CR1010 Ring Girder Shim, Colonial Ht. No. A86743 N/A N/A 2001 Replacement No A109-CRIOIO Ring Girder Shim, Colonial Ht. No. 4151614 N/A N/A 2001 Replacement No A109-CRIOIO Ring Girder Shim, Colonial Ht. No. R4747 N/A N/A 2001 Replacement No A36 Flat Bar Backing KNPP JB8913 N/A QADC 0 1-349 2001 Replacement No Strip, A36 Ring Girder Shim, Colonial Ht. No. 4125164 N/A N/A 2001 Replacement No A109-CRIOO1 Back Bumper Colonial MRR-01030 N/A N/A 2001 Replacement No Bearing Plate and Pipes 3/4" Threaded Rod, Colonial Ht. No. 8991820 N/A N/A 2001 Replacement No A540 Gr B23, C12 3/4/4" Nut, A563 Colonial 31167PJ N/A N/A 2001 Replacement No 3/4" Washer, F436 Colonial 107494 N/A N/A 2001 Replacement No Back Bumper Shim, Colonial E1F023-A12 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial EIGI 19-A16 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial B1F669-C16 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial T2866 N/A N/A 2001 Replacement No A36 I

Page 4 of 5

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No Back Bumper Shim, Colonial A1C202-B20 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial A 1D370-B23 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial B1E825-B16 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial B1F555-C23 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial 64595 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial Y07405 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial 65747 N/A N/A 2001 Replacement No A36 Ring Girder Shim, Colonial Ht. No. 2A6386-N/A N/A 2001 Replacement No A36 E

Ring Girder Shim, Colonial Ht. No. 2A6593-N/A N/A 2001 Replacement No A36 E

Snubber Bracket Colonial Ht No C0453 N/A N/A 2001 Replacement No Shim Page 5 of 5

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation 700 North Adams P.O. Box 19001 Green Bay, WI 54307-9001 Date: 12/12/01 Sheet: 1 of 2
2. Plant: Kewaunee Nuclear Power Plant N490 HWY 42 K4.waiine. Wl 54216-9511I Unit: No. 1 Work Order#: SEE BELOW WORK ORDER WP&IR DESCRIPTION 01-013145 M-SGA-362 REMOVE SHIPPING COVER 01-013376 M-SDS-322 SEVER STEAM DOME 01-008136 M-SDA-370 REFURBISH STEAM DOME 01-013376 M-SDA-372 RE-INSTALL STEAM DOME
3.
4.
5.

6.

Work Performed by: Bechtel Construction Identification of System:

05/06 Class:

2 Name: "A" Steam Generator Secondary Side (a) Applicable Construction Code: USAS B31.1, 1967 Ed., No Add.

Code Case:

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add.

Code Case:

Identification of Components Repaired or Replaced and Replacement Components:

N/A N-416-2 Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial No.

Board Identification Built

Replaced, Code No.

or Stamped Replacement Yes/No Steam Dome Westinghouse 1141 68-28 N/A 1970 Repaired Yes Replacement SG Ansaldo 202 151 N/A 2000 Replacement Yes Lower assembly Feedwater Nozzle PCI FW # 1 N/A MRR-01019 2001 Replacement No Adaptor Main Steam Flow Ansaldo N/A N/A QADC-01-041 2000 Replacement No Limiter I _______________

7. Description of Work: Prep New lower assembly for Steam Dome installation, Remove Steam Dome from the Old Lower Assembly, Refurbish the Feedwater Nozzle, Install the Main Steam Flow Limiter, Install the Steam Dome on the New Lower Assembly
8. Tests Conducted:

Hydrostatic El Pneumatic El Nominal Operating Pressure Other: E] Pressure: 1040 psi Test Temp: 549.35°F

Page 1 of2 Kewaunee WI 54216-9511

Date: 12/12/01 Name of Component: SG # A Work Order Number: 01-013145, 01-008136, 01-013376.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code,Section XI repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed:

1(uf% /

Expiration Date N/A Date (.

uwner or uwner s uesigjnee, I We CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the periodn'-/7Z-to I-t'p

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward)

Commissions f t

n ý

  • </ 'I I/a.(

Inspector s Signature/

National Board, State, Province, and Endorsements Date:

200\\

Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation 700 North Adams P.O. Box 19001 Green Bay, WI 54307-9001
2. Plant: Kewaunee Nuclear Power Plant N490 HWY 42 Kp~w*inp.* WI 54216-9511I Date: 12/12/01 Sheet: 1 of 4 Unit: No.1 Work Order# : SEE BELOW WORK ORDER WP&IR DESCRIPTION 01-013376 M-LLR-314 Replace Upper Col.

Adapters and Reshim Lower Lateral Restraint

3.
4.
5.

6.

Work Performed by: Bechtel Construction Identification of System:

36 Class:

1 Name: "B" Col. Adapter Plates and Lower Lateral Shims (a) Applicable Construction Code: USAS B31.1, 1967 Ed., No Add.

Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add.

Code Case: N/A Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial No.

Board Identification Built

Replaced, Code No.

or Stamped Replacement Yes/No See continuation sheet, page 3

7. Description of Work: Replaced steam generator support upper column adapters and removed and restored lower lateral support bumper guides to the steam generator and shimmed the adjacent support bumper steel.

Exempt 0 Page 1 of 4

8. Tests Conducted:

Hydrostatic E] Pneumatic E Nominal Operating Pressure El Other: []

Pressure:

psi Test Temp Kewaunee WI 54216-9511

Date: 12/12/01 Name of Component: "B" Upper Col. Adapter Plates and Reshim Lower Lateral Restraint.

Work Order Number: 01-013376 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code,Section XI repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed:

KA%*

-5,,

Owner or Owner's Desianec Expiration Date N/A Dateý.2.//,Mw CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period 05 -,/ti1 to. -

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward)__

Commissions ^'-Z3 ii c c*V('i9V' Inspector's Signature/

National Board, State, Province, and Endorsements Date

[1 1 2001 Page 2 of 4 I Itl*

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No Shims Colonial Ht. No. 4125164 N/A N/A 2001 Replacement No Shims Colonial Ht. No. A86743 N/A N/A 2001 Replacement No Shims Colonial Ht. No. 4151614 N/A N/A 2001 Replacement No Shims Colonial Ht. No. 2A6593-N/A N/A 2001 Replacement No A

Shims Colonial Ht. No. T 1273-A N/A N/A 2001 Replacement No Shims Colonial Ht. No. 1 E802 N/A N/A 2001 Replacement No Shims Colonial Ht. No. R6759 N/A N/A 2001 Replacement No Shims Colonial Ht. No. 2A6387-N/A N/A 2001 Replacement No A

Shims Colonial Ht. No. R6791 N/A N/A 2001 Replacement No Shims Colonial Ht. No. 2A6593-N/A N/A 2001 Replacement No E

Shims Colonial Ht. No. 2A6386-N/A N/A 2001 Replacement No D

Shims Colonial Ht. No. 2A6384-N/A N/A 2001 Replacement No A

Shims Colonial Ht. No. TI273-B N/A N/A 2001 Replacement No Shims Colonial Ht. No. R4747 N/A N/A 2001 Replacement No Shims Colonial Ht. No. 1E803 N/A N/A 2001 Replacement No Shims Colonial Ht. No. R6791 N/A N/A 2001 Replacement No Shims Colonial Ht. No. 1E542 N/A N/A 2001 Replacement No 1" Bolts A325 Colonial Ht. No. 706907 N/A N/A 2001 Replacement No 1" Bolts A325 Colonial Ht. No. 213265 N/A N/A 2001 Replacement No 1" Flat Washers Colonial Ht. No. B28393 N/A N/A 2001 Replacement No F436-93 I" Hex. Hd. Nuts Colonial Ht. No. S41165 N/A N/A 2001 Replacement No A194 Gr. 2H 3/4" Bolt, A-490 Colonial Ht. No. 8996654 N/A N/A 2001 Replacement No 3/4" Lockwashers Colonial Ht. No. 43739D N/A N/A 2001 Replacement No B 18.21 S.G. Col. Adapter Colonial Fabricated N/A MRR 01042 2001 Replacement No A588 Assembly Page 3 of 4

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No S.G. Col. Adapter Colonial Ht. No.

N/A N/A 2001 Replacement No Pin AISI 4340 8996496C0477 2 0 R p a e n

N S.G. Col. Adapter Colonial Ht. No.

N/A N/A 2001 Replacement No Pin Washer A-588, 803M62250 Gr. A S.G. Col. Adapter Colonial Ht. No. 255029 N/A N/A 2001 Replacement No Pin Washer Bolts Trace Code I UX A-325 S.G. Adapter Col.

Colonial Ht. No. 10618 N/A N/A 2001 Replacement No Adapter Bolts A-Trace No. IUU 54 0, G r. B 23, C l. 2 2001_R place entN S.G. Adapter Col.

Colonial Ht. No. S42483, N/A N/A 2001 Replacement No Jam Nuts, SA307 Trace No. IUY Gr. B S.G. Adapter Col.

Colonial Ht. No. 8994464 N/A N/A 2001 Replacement No Heavy Hex. Nut, Ht Code SBG SA 194 Gr. 2H S.G. Col. Adapter Colonial Ht. No. 8997945 N/A N/A 2001 Replacement No Washers AISI 4150 Trace Code I UW I--

I I.

I*

-I-I 1

I

+

I I

1 I

F

+

I I

1 F

F I

I I

1 I

F I

I I

t

_ I I

I I

I 1I Page 4 of 4

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation 700 North Adams P.O. Box 19001 Green Bay, WI 54307-9001
2. Plant: Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511 Date: 12/13/01 Sheet: 1 of 2 Unit: No. 1 Work Order#: SEE BELOW WORK ORDER WP&IR DESCRIPTION 01-008135 M-BDA-382 S.G. "A" BLOWDOWN CUT / REWELD 01-008135 M-BDB-383 S.G. "B" BLOWDOWN CUT / REWELD 01-013145 M-SGA-364 S.G. "A" SMALL BORENOZZLE PREPS 01-013145 M-SGB-365 S.G. "B" SMALL BORE NOZZLE PREPS
3. Work Performed by: Bechtel Construction
4. Identification of System:

07 Class:

2 Name: BLOWDOWN

5. (a) Applicable Construction Code: USAS B31.1, 1967 Ed., No Add.

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add.

Code Case: N/A Code Case: N-416-2

6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial No.

Board Identification Built

Replaced, Code No.

or Stamped Replacement Yes/No SG LOOP-A N/A N/A N/A N/A N/A Repaired No BLOWDOWN PIPING SG LOOP-A ANSALDO 202 151 N/A 2000 Replacement Yes LOWER ASSY BLOWDOWN NOZZLE SG LOOP-B N/A N/A N/A N/A N/A Repaired No BLOWDOWN PIPING SG LOOP-B ANSALDO 201 150 N/A 2000 Replacement Yes LOWER ASSY BLOWDOWN NOZZLE

7. Description of Work: TEMPORARY REMOVAL OF EXISTING BLOWDOWN PIPING AT EACH STEAM GENERATOR OUTLET NOZZLE AND PREPERATION OF BLOWDOWN NOZZLES ON NEW STEAM GENERATOR LOWER ASSEMBLIES. ALL PIPING WAS PREPARED AND REINSTALLED BY WELDING.
8. Tests Conducted:

Hydrostatic F] Pneumatic E]

Nominal Operating Pressure [*

Exempt rl Other: [] Pressure: A-1040 psi / B-1030 psi Test Temp: A-549.35°F / B-548.17°F

Date: 12/13/01 Name of Component: BLOWDOWN Work Order Number: 01-008135 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code,Section XI repair or replacement.

N/A Type Code Symbol Stamp Certificate of Authorization No.

N/A Expiration Date N/A Signed:

  • 4*

Ak*qJftR SA-,cz5'"-

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period 65 -I>"-*

to 1 tI '

\\

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward)

Commissions r,3 ii S-) A,.Qi L-'-

/( Y 9 Inspect& 'SIgf' ture National Board, State, Province, and Endorsements Date: ___

.2001 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Page 2 of 2 Date I/j*a/K L

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation 700 North Adams P.O. Box 19001 Green Bay, WI 54307-9001 Date: 12/13/01 Sheet: 1 of 5
2. Plant: Kewaunee Nuclear Power Plant N490 HWY 42 IKowai~n*. WI 54216-9511 Unit: No. 1 Work Order#: SEE BELOW WORK ORDER WP&IR DESCRIPTION 01-008137 M-ULR-312 Remove & Modify Upper Lateral
3. Work Performed by: Bechtel Construction
4. Identification of System:

5A Class:

2 Name: "B" Upper Lateral inclu Snubber

5. (a) Applicable Construction Code: USAS B31.1, 1967 Ed., No Add.

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add.

6. Identification of Components Repaired or Replaced and Replacement Components:

ding Spring Cans &

Code Case: N/A Code Case: N/A Name of Name of Manufacturer National Other Year

Repaired, ASM:

Component Manufacturer Serial No.

Board Identification Built

Replaced, Code No.

or Stamped Replacement Yes/No See continuation sheet, page 3 1

4-

-k I

F I

4-4-

4 1

F I

4-I I

F I

.1.

L A ______

i __________

L ___

J

7. Description of Work: Repaired Upper Lateral Restraint and replacement of bolting and shims for upper lateral
8. Tests Conducted:

Hydrostatic E] Pneumatic E]

Nominal Operating Pressure n Exempt Z Other: n Pressure:

psi Test Temp oF.

Page 1 of 5 Kewaunee WI 54216-9511

Date: 12/13/01 Name of Component: UPPER LATERAL RESTRAINT SYSTEM.

Work Order Number: 01-008137 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code,Section XI repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed: 2L4

ý KL-pPpmq;ýSý Expiration Date N/A Date

/ i/ol "Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period C9-/'f2"rl to -

K-'0"*

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected wi this inspection.

(Robert T. Ward)

Commissions p

/ i-*?ApJ/?

L-j *"/i('$'

Inspec sSignature/

National Board, State, Province, and Endorsements Date:

2001 Page 2 of 5

Name of Component "B" Hydraulic Snubber "B" Upper Lateral Ring Girder Splice Plate, Ring Girder, ASTM A588, Gr. A Splice Plate Bolt, ASTM A540, Gr.B23, Cl. 2 Splice Plate Heavy Hex. Nuts, A194, Gr. 2H Splice Plate Washers, F436 Splice Plate Heavy Hex Nuts, A 194, Gr. 2H Bumper Plate, A588 Side Bumper Bearing Plate, A588 3/4" Threaded Rod, A540 Gr. B23, Cl. 2 3/4" Hex. Nut, A563 Washer, F436 Side Bumper Shim, A36 Side Bumper Shim, A36 Side Bumper Shim, A36 Side Bumper Shim, A36 Side Bumper Shim, A36 Side Bumper Shim, A36 Side Bumper Shim, A36 Side Bumper Shim, A36 Side Bumper Shim, A36 Side Bumper Shim, A109 CIO10 Side Bumper Shim, A109 C1010 Side Bumper Shim, A109 CI010 Side Bumper Shim, A109 CI010 Washer Plate, A36 Upper Lateral Ring Plate, A36 Nai Ma N/A N/A Col FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet me of Manufacturer National Other Year Re nufacturer Serial No.

Board Identification:

Built Re No.

Or Re N/A N/A N/A N/A Re k

N/A N/A N/A N/A Re onial Ht. No. 412H07 N/A N/A 2001 Re Colonial Colonial Colonial Colonial Colonial Colonial Colonial Colonial Colonial Colonial Colonial Colonial Colonial Colonial Colonial Colonial Colonial Colonial Colonial Colonial Colonial Colonial Colonial Colonial HT No. 10187 RYE Ht. No. 8994464 Trace Code SBG Ht. No. Y85307 Trace Code SBH Ht. No. S42483 Trace Code I UV Ht. No. BIS6214 Ht. No. 1B518 Ht. No. 8991820 Ht. No. 34467PJ Ht. No. 107494 Ht. No. EIF023 A12 Ht. No. E1GI19 A16 Ht. No. EIG119 A16 Ht. No. B1F669 C16 Ht. No. T2866 Ht. No. Al C202 B20 Ht. No. A1D370 B32 Ht. No. BIE825 B16 Ht. No. BIF555 C23 Ht. No. 64595 Ht. No. Y07405 Ht. No. 65747 Ht. No. M06708 Ht. No. 404875 Ht. No. A1T1203 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Re paired placed placement paired paired placement placement F ASME Code Stamped Yes/No No No No No No No No No No No No No No No No No No No No No No No No No No No No Page 3 of 5 Re 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No 3/8" Threaded Rod, Colonial Ht. No. 813953 N/A N/A 2001 Replacement No A307, Gr. A Heavy Hex Nuts, Colonial Ht. No. A61415 N/A N/A 2001 Replacement No A563, Gr. A Std. Washer, F436, Colonial Ht. No. B 16294 N/A N/A 2001 Replacement No Type I Upper Lateral Ring Colonial Ht. No. AIU1599 N/A N/A 2001 Replacement No Plate Shim, A36 Upper Lateral Ring Colonial Ht. No. BIP5527 N/A N/A 2001 Replacement No Plate Shim, A36 3/8" Hex Hd. Bolt, Colonial Ht. No. 8878678 N/A N/A 2001 Replacement No A307-97 3/8" Std. Washer, Colonial Ht. No. B16294 N/A N/A 2001 Replacement No F436 Type I Ring Girder Shim, Colonial Ht. No. 1E479 N/A N/A 2001 Replacement No A36 Ring Girder Shim, Colonial Ht. No. 1 E744 N/A N/A 2001 Replacement No A36 Ring Girder Shim, Colonial Ht. No. 2A6386-N/A N/A 2001 Replacement No A36 C

Ring Girder Shim, Colonial Ht. No. 2A6593-N/A N/A 2001 Replacement No A36 C

Ring Girder Shim, Colonial Ht. No. 4151614 N/A N/A 2001 Replacement No A109-CRI010 Ring Girder Shim, Colonial Ht. No. A86743 N/A N/A 2001 Replacement No A109-CRIOIO Ring Girder Shim, Colonial Ht. No. R4747 N/A N/A 2001 Replacement No A36 Flat Bar Backing KNPP JB8913 N/A QADC 01-349 2001 Replacement No Strip, A36 Ring Girder Shim, Colonial Ht. No. 4125164 N/A N/A 2001 Replacement No A109-CRIOIO Back Bumper Colonial MRR-01030 N/A N/A 2001 Replacement No Bearing Plate and Pipes 3/4" Threaded Rod, Colonial Ht. No. 8991820 N/A N/A 2001 Replacement No A540 Gr B23, C12 3/4" Nut, A563 Colonial 31167PJ N/A N/A 2001 Replacement No 3/4" Washer, F436 Colonial 107494 N/A N/A 2001 Replacement No Back Bumper Shim, Colonial E1F023-A12 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial EIGI 19-A16 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial BIF669-C16 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial T2866 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial A1C202-B20 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial A1D370-B23 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial B1E825-B16 N/A N/A 2001 Replacement No A36 Page 4 of 5

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No Back Bumper Shim, Colonial BIF555-C23 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial 64595 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial Y07405 N/A N/A 2001 Replacement No A36 Back Bumper Shim, Colonial 65747 N/A N/A 2001 Replacement No A36 Ring Girder Shim, Colonial Ht. No. 2A6386-N/A N/A 2001 Replacement No A36 E

Ring Girder Shim, Colonial Ht. No. 2A6593-N/A N/A 2001 Replacement No A36 E

3/4" Nut, A563-93 Colonial 107494 N/A N/A 2001 Replacement No TYPE 1 1

1 Page 5 of 5

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation 700 North Adams P.O. Box 19001 Green Bay, WI 54307-9001
2. Plant: Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee WI 54216-9511 Date: 12/12/01 Sheet: 1 of 2 Unit: No.1 Work Order#:

SEE BELOW WORK ORDER WP&IR DESCRIPTION 01-013145 M-SGB-363 REMOVE SHIPPING COVER 01-013376 M-SDS-323 SEVER STEAM DOME 01-008136 M-SDB-371 REFURBISH STEAM DOME 01-013376 M-SDB-373 RE-INSTALL STEAM DOME

3. Work Performed by: Bechtel Construction
4. Identification of System:

05/06 Class:

2 Name: "B" Steam Generator Secondary Side

5. (a) Applicable Construction Code: USAS B31.1, 1967 Ed., No Add.

Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add.

6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year Component Manufacturer Serial No.

Board Identification Built No.

Steam Dome Westinghouse 1142 68-29 N/A 1970 Code Case: N-416-2

Repaired, Replaced, or Replacement Repaired Replacement SG Ansaldo 201 150 N/A 2000 Replacemen Lower assembly Feedwater Nozzle PCI FW# 2 N/A MRR-01019 2001 Replacemen Adaptor I..

,,,, l.

Main Steam Flow Ansaldo N/A N/A Limiter It t

ASME Code Stamped Yes/No Yes Yes No No

7. Description of Work: Prep New lower assembly for Steam Dome installation, Remove Steam Dome from the Old Lower Assembly, Refurbish the Feedwater Nozzle, Install the Main Steam Flow Limiter, Install the Steam Dome on the Niew Lower seby
8. Tests Conducted:

Hydrostatic E] Pneumatic El Nominal Operating Pressure Z*

Exempt [1 Pressure: 1030 psi Test Temp 548.17 OF

Rep ace,./

,L!31 t nI QAUL;-U - 1

/-UUU uome on me New LOWS[ / 55 lllUly.

Date: 12/12/01 Name of Component: SG # B Work Order Number: 01-013145, 01-013376, 01-008136.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code,Section XI repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date Signed:

4--Jp-Q D

Owner or Owner's Designee, Title N/A ate___________

Page 2 of 2 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period (tc-)L/"-0 to "I

I

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XA By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward)

Commissions &;& (/S5"5) tJ5F Q q iLc 4' Inspector ifgnature/

National Board, State, Province, and Endorsements Date:

I~-I*200\\

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation 700 North Adams P.O. Box 19001 Green Bay, WI 54307-9001
2. Plant: Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511 Date: 12/13/01 Sheet: 1 of 3 Unit: No.1 Work Order#: SEE BELOW WORK ORDER WP&IR DESCRIPTION 01-008139 M-FWA-380 S.G. "A" FW /AFW CUT OUT AND WELD 01-008139 M-FWB-381 S.G. "B" FW /AFW CUT OUT AND WELD
3. Work Performed by: Bechtel Construction
4. Identification of System:

05A/05B Class:

2 Name: FEEDWATER / AFW

5. (a) Applicable Construction Code: USAS B31.1, 1967 Ed., No Add.

Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add.

6. Identification of Components Repaired or Replaced and Replacement Components:

Code Case: N-416-2 Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial No.

Board Identification Built

Replaced, Code No.

or Stamped Replacement Yes/No SEE CONTINUATION, SHEET 3

7. Description of Work: TEMPORARY REMOVAL OF EXISTING FEEDWATER PIPING AT EACH STEAM GENERATOR OUTLET NOZZLE. TEMPORARY REMOVAL OF EXISTING AUXILLARY FEEDWATER PIPING AT THE MAIN FEEDWATER BRANCH AT EACH STEAM GENERATOR. WELD REPAIRS ON BOTH REMOVED FEEDWATER SPOOLS AND REPLACEMENT OF FEEDWATER VENT VALVE ASSEMBLY (FW-80 A / B) CONNECTIONS USING NEW SOCKOLET AND INSERT REDUCER FITTINGS. ALL PIPING WAS PREPARED AND REINSTALLED BY WELDING
8. Tests Conducted:

Hydrostatic Fl Pneumatic El Nominal Operating Pressure [*

Exempt E]

Other: F] Pressure: [A-FW 1040 psi / AFW 1040 psi] [ B-FW 1030 psi / AFW 1030 psi]

Test Temp: [A-FW 549.351F / AFW 570F] [B-FW 548.17'F / AFW 57°F]

Date: 12/13/01 Name of Component: FEEDWATER / AUXILLARY FEEDWATER Work Order Number: 01-008139 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code,Section XI repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date Signed:

o4L',-

AP4UP-*P DS' or flun,r' ninnA Title N/A ate/ 41sl(

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period 09-f!)-f I

to I (- ?P-C,

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward)

Commissions A

tV ) A1-

.-A.'

?

c/-1/'

Inspector's Signature National Board, State, Province, and Endorsements Date:

t 0) -r 20O0 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Page 2 of 3

/

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No SG LOOP-A N/A N/A N/A N/A N/A REPAIRED YES FEEDWATER SG LOOP-A N/A N/A N/A N/A N/A REPAIRED YES AUXILLARY FEEDWATER SG LOOP-B N/A N/A N/A N/A N/A REPAIRED YES FEEDWATER SG LOOP-B N/A N/A N/A N/A N/A REPAIRED YES AUXILLARY FEEDWATER SOCKOLET N/A N/A N/A HT# 2016 ANB REPLACEMENT NO 16"X 2" QADC 01-408 REDUCING N/A N/A N/A HT# 1566 ANB REPLACEMENT NO INSERT 2" X 1" QADC 01-408 Page 3 of 3

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation 700 North Adams P.O. Box 19001 Green Bay, WI 54307-9001
2. Plant: Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee WI 54216-9511
3.
4.
5.

6.

Date: 12/12/01 Sheet: 1 of 2 Unit: No.1 Work Order#: SEE BELOW WORK ORDER WP&IR DESCRIPTION 01-005474 M-IWR-394 S.G. "A" INSTALL LEVEL INSTR. WIDE RANGE 01-005474 M-IWR-395 S.G. "B" INSTALL LEVEL INSTR. WIDE RANGE Work Performed by: Bechtel Construction Identification of System:

06 Class:

2 Name: MAIN STEAM AND STEAM DUMP (a) Applicable Construction Code: USAS B31.1. 1967 Ed., No Add.

Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add.

Code Case: N-416-2 Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial No.

Board Identification Built

Replaced, Code No.

or Stamped Replacement Yes/No CONDENSATE KNPP N/A N/A QADC 01-393 2001 REPLACEMENT NO POT HT 85188

7. Description of Work: INSTALL NEW UPPER WIDE RANGE TAP, CONDENSATE POT AND TUBING.
8. Tests Conducted:

Hydrostatic Dl Pneumatic [I Nominal Operating Pressure Z*

Exempt E]

Other: E] Pressure: A-1 040 psi / B-1 030 psi Test Temp: A-549.35°F / B-548.17°F

Date: 12/12/01 Name of Component: MAIN STEAM AND STEAM DUMP Work Order Number: 01-005474 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code,Section XI repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed: *

-/%*,"'

1F*,L k-,

TIA Date Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period OC -31 to I I 3-1**

ý

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward)

Commissions 0J1%

1 55") A4 UL o) 4/..y Inspector's Signature National Board, State, Province, and Endorsements Date:

t*

20-X).

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation 700 North Adams P.O. Box 19001 Green Bay, WI 54307-9001
2. Plant: Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee Wl 54216-9511 Date: 12/12/01 Sheet: 1 of 2 Unit: No.1 Work Order#: SEE BELOW WORK ORDER WP&IR DESCRIPTION 01-008141 M-MSA-350 S.G. "A" MS CUT OUT AND WELD 01-008141 M-MSB-351 S.G. "B" MS CUT OUT AND WELD
3. Work Performed by: Bechtel Construction
4. Identification of System:

06 Class:

2 Name: MAIN STEAM

5. (a) Applicable Construction Code: USAS B31.1, 1967 Ed.,No Add.

(b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add.

6. Identification of Components Repaired or Replaced and Replacement Components:

Code Case: N/A Code Case: N-416-2 Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial No.

Board Identification Built

Replaced, Code No.

or Stamped Replacement Yes/No SG LOOP-A N/A N/A N/A N/A N/A REPAIRED YES MAIN STEAM SG LOOP-B N/A N/A N/A N/A N/A REPAIRED YES MAIN STEAM 1 "GAMMA PORT COLONIAL HT # 87261 N/A N/A 2000 REPLACEMENT NO PLUG X 1" LG MACHINE HT CODE A696 GR C COMPANY, INC.

AEM 1 "GAMMA PORT WFI HT # 8998228 N/A N/A 2001 REPLACEMENT NO PLUG X 2" LG INTERNATIONAL HT CODE A696 GR C 297YNB

7. Description of Work: TEMPORARY REMOVAL OF EXISTING MAIN STEAM PIPING AT EACH STEAM GENERATOR OUTLET NOZZLE. EXISTING PIPING WAS PREPARED AND REINSTALLED BY WELDING.

REINSTALLATION INCLUDES ADDITION OF TWO NEW RADIOGRAPHY GAMMA PORTS AND PLUGS PER LOOP.

8. Tests Conducted:

Hydrostatic E] Pneumatic E]

Nominal Operating Pressure Exempt E]

Other: 0 Pressure: A-1 040 psi/ B-1 030 psi Test Temp: A-549.35°F / B-548.17°F

Date: 12/12/01 Name of Component: MAIN STEAM Work Order Number: 01-008141 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code, Section X1 repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed:

7,, "*

.Date Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period p9-/?-oj to /I-

?-,-

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward)

CommissionstX3_ii&ý)

A,,.; cT Y6/,

Inspec s Signature National Board, State, Province, and Endorsements Date:

h. "1 '*

20kO FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation 700 North Adams P.O. Box 19001 Green Bay, WI 54307-9001
2. Plant: Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee WI 54216-9511 Date: 12/12/01 Sheet: 1 of 2 Unit: No.1 Work Order#: SEE BELOW WORK ORDER WP&IR DESCRIPTION 01-008137 M-RCS-366 S.G. "A" RCS CUT OUT AND WELD 01-008133 M-RCS-360 S.G. "A" RCS NOZZLE PREP
3. Work Performed by: Bechtel Construction
4. Identification of System:

36 Class:

1 Name: REACTOR COOLANT

5. (a) Applicable Construction Code: USAS B31.1, 1967 Ed.,No Add.

Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add.

Code Case: N-416-2

6. Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial No.

Board Identification Built

Replaced, Code No.

or Stamped Replacement Yes/No STEAM WESTINGHOUSE 1141 68-28 NONE 1970 REPAIRED YES GENERATOR STEAM ANSALDO 202 151 QADC-00-376 2000 REPLACEMENT YES GENERATOR 11/2" CAP WESTINGHOUSE N/A N/A HT# 8000913, N/A REPLACEMENT NO SCREW HT CODE RVP 1 1/2" CAP WESTINGHOUSE N/A N/A HT 204394, N/A REPLACEMENT NO SCREW HT CODE SAZ

7. Description of Work: THE EXISTING WESTINGHOUSE LOWER ASSEMBLY WAS SEVERED FROM REACTOR COOLANT PIPING. A NEW LOWER ASSEMBLY WAS PREPARED. INSTALLED. AND CONNECTED TO THE REACTOR COOLANT PIPING BY WELDING.
8. Tests Conducted:

Hydrostatic E] Pneumatic El Nominal Operating Pressure Exempt El Other: El Pressure: 2240 psi Test Temp: 551.1OF

Date: 12/12/01 Name of Component: REACTOR COOLANT Work Order Number: 01-008137, 01-008133 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code,Section XI repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed:.4---

1..

"£ K

4fA ac- -I*>v Expiration Date N/A Date /I/'cf Owner or Owner's DesiQnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period 09-//9 to ___-

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward)

Commissions S.)3115S'7,JJ.

U*.-

3 2(&'1 InspecteA -Signature National Board, State, Province, and Endorsements Date:

to-r%

2001 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Page 2 of 2 f

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation 700 North Adams P.O. Box 19001 Green Bay, WI 54307-9001
2. Plant: Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee WI 54216-9511
3. Work Performed by: Bechtel Construction
4. Identification of System:

36 Class:

5. (a) Applicable Construction Code: USAS B31.1, 1967 E (b) Applicable Edition of Section X1 Utilized for Repairs or
6. Identification of Components Repaired or Replaced Name of Name of Manufacturer P

Component Manufacturer Serial No.

E STEAM WESTINGHOUSE 1142 6

GENERATOR STEAM ANSALDO 201 1

GENERATOR 11/2" CAP WESTINGHOUSE N/A h

SCREW 11/2' CAP WESTINGHOUSE N/A SCREW Date: 12/12/01 Sheet: 1 of 2 Unit: No.1 Work Order#: SEE BELOW WORK ORDER WP&IR DESCRIPTION 01-008137 M-RCS-367 S.G. "B" RCS CUT OUT AND WELD 01-008133 M-RCS-361 S.G. "B" RCS NOZZLE PREP 1

Name: REACTOR COOLANT

-d.,No Add.

Code Case: N/A Replacements: 1989, No Add.

Code Case: N-416-2 and Replacement Components:

Jational Other Year

Repaired, ASMIE Board Identification Built
Replaced, Code 0o.

or Stamped Replacement Yes/No 8-29 NONE 1970 REPAIRED YES 50 QADC 00376 2000 REPLACEMENT YES N/A HT# 8000913, N/A REPLACEMENT NO HT CODE RVP VA HT 204394, N/A REPLACEMENT NO HT CODE SAZ

7. Description of Work: THE EXISTING WESTINGHOUSE LOWER ASSEMBLY WAS SEVERED FROM REACTOR COOLANT PIPING. A NEW LOWER ASSEMBLY WAS PREPARED, INSTALLED, AND CONNECTED TO THE REACTOR COOLANT PIPING BY WELDING.
8. Tests Conducted:

Hydrostatic E] Pneumatic E]

Nominal Operating Pressure [

Exempt El Other: E] Pressure: 2240 psi Test Temp: 551.1F

Date: 12/12/01 Name of Component: REACTOR COOLANT Work Order Number: 01-008137, 01-008133 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code, Section Xl repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed:

A

/4t-/

P4.r Expiration Date N/A Date 1!ý/

7

/

Owner or Owner's Designee, I tle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period 05/

I to P

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward)

Commissions AA Ill'S'2dIJ; G"-s P'V(- Y..iA Ins p(ýsSig nature National Board, State, Province, and Endorsements Date:

200(

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Page 2 of 2

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions for the ASME Code Section XI

1. Owner: Wisconsin Public Service Corporation 700 North Adams P.O. Box 19001 Green Bay, WI 54307-9001
2. Plant: Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee WI 54216-9511
3.
4.
5.

6.

Date: 12/12/01 Sheet: 1of 4 Unit: No.1 Work Order# : SEE BELOW WORK ORDER WP&IR DESCRIPTION 01-013376 M-LLR-313 Replace Upper Col.

Adapters and Reshim Lower Lateral Restraint Work Performed by: Bechtel Construction Identification of System:

36 Class:

1 Name: "A" Col. Adapter Plates and Lower Lateral Shims (a) Applicable Construction Code: USAS B31.1, 1967 Ed.,No Add.

Code Case: N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1989, No Add.

Code Case: N/A Identification of Components Repaired or Replaced and Replacement Components:

Name of Name of Manufacturer National Other Year

Repaired, ASME Component Manufacturer Serial No.

Board Identification Built

Replaced, Code No.

or Stamped Replacement Yes/No See continuation sheet, page 3

7. Description of Work: Replaced steam generator support upper column adapters and removed and restored lower lateral suDport bumper guides to the steam generator and shimmed the adiacent support bumper steel.

Exempt Z OF Page 1 of 4

8. Tests Conducted:

Hydrostatic [] Pneumatic E]

Nominal Operating Pressure El Other: []

Pressure:

psi Test Temp

Date: 12/12/01 Name of Component: "A" Upper Col. Adapter Plates and Reshim Lower Lateral Restraint.

Work Order Number: 01-0133760 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair and replacement conforms to the rules of the ASME Code, Section Xl repair or replacement.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Expiration Date N/A Signed:

eH

$--V Date 4

I Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler Pressure Vessel Inspectors and the State or Providence of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in this Owner's Report during the period C')C -/ ) -0i1 to I

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or of loss of any kind arising from or connected with this inspection.

(Robert T. Ward)

Commissions 6 ii

-),,4 Inspecti_'s-gfiature National Board, State, Province, and Endorsements Date:

- Is 2001 Page 2 of 4

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Continuation Sheet Name of Component Shims Shims Shims Shims Shims Shims Shims Shims Shims Shims Shims Shims Shims Shims V" Bolts A325 I" Bolts A325 1" Flat Washers F436-93 I" Hex. Hd. Nuts A194 Gr. 2H 3/4" Lockwashers B18.21 S.G. Col. Adapter A588 S.G. Col. Adapter Pin AISI 4340 S.G. Col. Adapter Pin Washer A-588, Gr. A S.G. Col. Adapter Pin Washer Bolts A-325 Name of Manufacturer Manufacturer Serial No.

Colonial Ht. No. 264344 Colonial Ht. No. 812J3592 Colonial Ht. No. 4126617 Colonial Ht. No. 4122060 Colonial Ht. No. 4155918 Colonial Ht. No. 4125164 Colonial Ht. No. A86743 Colonial Ht. No. 4151614 Colonial Ht. No. 2A6593 A

Colonial Ht. No. T1273-A Colonial Ht. No. I E802 Colonial Ht. No. R6759 Colonial Ht. No. R6791 Colonial Ht. No. I E542 Colonial Ht. No. 706907 Colonial Ht. No. 213265 Colonial Ht. No. B28393 Colonial Ht. No. S41165 Colonial Ht. No. 43739D Colonial Fabricated Assembly Colonial Ht. No.

8996496C0477 Colonial Ht. No.

803M62250 Colonial Ht. No. 255029 Trace Code I UX National Other Board Identification.

No.

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A MRR 1042 N/A N/A N/A N/A N/A N/A Year Built 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 2001 I Replacement Page 3 of 4 Repaired Replaced Or Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement Replacement ASME Code Stamped Yes/No No No No No No No No No No No No No No No No No No No No No No No No

Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial No.

Board Identification:

Built Replaced Code No.

Or Stamped Replacement Yes/No S.G. Adapter Col.

Colonial Ht. No. 10618 N/A N/A 2001 Replacement No Adapter Bolts A-Trace No. IUU 540, Gr. B23, Cl. 2 S.G. Adapter Col.

Colonial Ht. No. S42483, N/A N/A 2001 Replacement No Jam Nuts, SA307 Trace No. 1UY Gr. B S.G. Adapter Col.

Colonial Ht. No. 8994464 N/A N/A 2001 Replacement No Heavy Hex. Nut, Ht Code SBG SA 194 Gr. 2H S.G. Col. Adapter Colonial Ht. No. 8997945 N/A N/A 2001 Replacement No Washers AISI 4150 Trace Code 1UW

%" Hex Head Bolt, Colonial 8996654 N/A N/A 2001 Replacement No A-490 I

4 4

+

+

4 4

+/-

t t

4 4

+/-

+/-

t 4

4

+

I t

+

  • 1

1 T

I I

[

1 1 F

Page 4 of 4

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 33 Class 1 SAFETY INJECTION
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Manufacturer Manufacturer Serial No.

ANCHOR/DARLING VALVE NF COMPANY National Board No.

NA Other ID S1115-002 Date 11/26/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-005013 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA Year Built 1970

Repaired, Replaced, or Replacement REPLACEMENT
7. Description of Work OPEN FOR INSPECTION CLASS 1 SAFETY INJECTION SYSTEM 12" VALVE SI-22B AND REPLACEMENT OF 1 VALVE BONNET STUD.
8. Tests conducted Hydrostatic Other D R

Pneumatic r]

Nominal Operating Pressure E

Pressure 750 psi Test Temp.

63 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached Name of Component SI-22B ASME Code Stamped N

Exempt 1

NIS-2 (Back)

Sheet 2 of 2 Date: 11/26/2001 Name of Component:

SI-22B Work Order Number: 01-005013 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed

£/ffiM geJ~g9U A

&OW14 Date Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period -74 S-D 0 to / 0 2-, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

7 i

4-1, Commissions NB7741, 1, N, IS, A WIS 100024 Inspector' Signature National Board, State, Province, and Endorsements Date a, t-A

/

,20 01.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 34 Class 2

RESIDUAL HEAT REMOVAL

5. (a) Applicable Construction Code NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component APRH1-IA Name of Manufacturer BRYON JACKSON Manufacturer Serial No.

681N0277 National Board No.

NA Other ID 00127 Date 11/27/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-005020 Type Code Sym. Stamp N._A Authorization No.

NA Expiration Date NA Code Case NA Year Built 1970

Repaired, Replaced, or Replacement REPAIRED
7. Description of Work INSPECT AND REBUILD CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM RESIDUAL HEAT REMOVAL PUMP 1A.
8. Tests conducted Hydrostatic Other F

7]

Pneumatic El Pressure 375 psi Nominal Operating Pressure

=l Test Temp.

341 deg. F

9. Remarks NOT APPLICABLE Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped N

Exempt 1

NIS-2 (Back)

Sheet 2 of 2 Date: 11/27/2001 Name of Component:

APRH1-IA Work Order Number: 01-005020 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed e, C.4 V

m&Aot.

ae6.ý D4ateL 20 Z

Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period A,-0o to /- 3 /-0Z, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspector's ignature National Board, State, Province, and Endorsements Date

/

20 e

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street. Hudson, Wisconsin 54016
4. Identification of System 35 Class 2

CHEMICAL AND VOLUME CONTROL

5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component LD-13 Name of Manufacturer CROSBY VALVE & GAGE CO.

Manufacturer Serial No.

NF National Board No.

NA Other ID CS014-001 Date 11/2912001 Sheet 1 of 2 Unit No. 1 Work Order 01-005030 Type Code Sym. Stamp N.A Authorization No.

NA Expiration Date NA Code Case NA Year Built 1971

Repaired, Replaced, or Replacement REPAIRED
7. Description of Work REMOVE FOR TESTING CLASS 2 CHEMICAL AND VOLUME CONTROL SYSTEM 2" VALVE LD-13.
8. Tests conducted Hydrostatic L]

Other D Pneumatic F

Nominal Operating Pressure El Pressure 84 psi Test Temp.

87 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturers Data Reports to be Attached ASME Code Stamped N

Exempt [:

NIS-2 (Back)

Sheet 2 of 2 Date: 11/29/2001 Name of Component:

LD-13 Work Order Number: 01-005030 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed 6k

ý__.*

(

y-,4-Date 4_

,20 O.L OV O

DeXi Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 1-2S-- 0 to /- 3/- 01, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

7 4

1 Commissions NB7741, I, N, IS, A WIS 100024 nspector'Sqnature National Board, State, Province, and Endorsements Date

/

,20 02

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 35 Class 2

CHEMICAL AND VOLUME CONTROL

5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Date 11/29/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-005031 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA
Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No.

Board No.

ID Built Replacement Stamped LD-5 CROSBY ASHTON GAGE NF NA CS109-001 1970 REPAIRED N

CO.

7. Description of Work REMOVE FOR TESTING CLASS 2 CHEMICAL AND VOLUME CONTROL SYSTEM 2" VALVE LD-5.
8. Tests conducted Hydrostatic Other F

--1 Pneumatic E Pressure 500 psi Nominal Operating Pressure 17 Test Temp.

250 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached Exempt 1:1

NIS-2 (Back)

Sheet 2 of 2 Date: 11/29/2001 Name of Component:

LD-5 Work Order Number: 01-005031 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed l.e/,aI

£.

.T-,44Q/LA Date L-20 OQ Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-,aS-0 O to /-/'-O3.-, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 Inspector' Signature National Board, State, Province, and Endorsements Date 2

/

,20 1,,-

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 36 Class 1

REACTOR COOLANT

5. (a) Applicable Construction Code ASME 111-1968 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Date 12/4/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-005033 Type Code Sym. Stamp N._A Authorization No. NA Expiration Date NA Code Case NA Name of Manufacturer Manufacturer Serial No.

CROSBY, ASHTON GAGE NF COMPANY National Board No.

NA Other Year ID Built RCOO8-001 1972 REPLALMN N

pI1-u,

Repaired, Replaced, or Replacement
7. Description of Work REMOVE CLASS 1 REACTOR COOLANT SYSTEM 6" VALVE PR-3A FOR TESTING AND REPLACING DICS INSERT.
8. Tests conducted Hydrostatic Other El El Pneumatic F

Pressure 2240 psi Nominal Operating Pressure E

Test Temp.

5_1 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached Name of Component PR-3A Code Stamped Exempt [-1 REPLACEME=NT N

RC008-001 1972

NIS-2 (Back)

Sheet 2 of 2 Date:. 12/4/2001 Name of Component:

PR-3A Work Order Number: 01-005033 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed Date

  • g 20 0-1 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period "2S-oO to /-,/-0,Z, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

4 = "Commissions NB7741, I, N, IS, A WIS 100024 Inspector's Signature National Board, State, Province, and Endorsements Date

,20 O

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 05B Class 2 AUXILIARY FEEDWATER
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component AFW-4B Name of Manufacturer WILLIAM POWELL CO.

Manufacturer Serial No.

61208 National Board No.

NA Other ID F015-002 Date 12/20/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-005272 Type Code Sym. Stamp N.A Authorization No.

NA Expiration Date NA Code Case NA Year Built 1972

Repaired, Replaced, or Replacement REPAIRED
7. Description of Work REPAIR CLASS 2 AUXILARY FEEDWATER SYSTEM 3" VALVE AFW-4B DUE TO IMPROPER SEATING.
8. Tests conducted Hydrostatic Other D]

LI Pneumatic F

Nominal Operating Pressure F]

Pressure 1030 psi Test Temp.

57 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped N

Exempt 1 N

NIS-2 (Back)

Sheet 2 of 2 Date:.12/20/2001 Name of Component:

AFW-4B Work Order Number: 01-005272 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed Date *'o

,20

_._20 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period I-*,*

00 to

,/-,/9*2, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

ln "Commissions NB7741, I, N, IS, A WIS 100024 Inspector's ignature National Board, State, Province, and Endorsements Date t

,20 6-.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 05B Class 2 AUXILIARY FEEDWATER
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Manufacturer WILLIAM POWELL CO.

Manufacturer Serial No.

NF National Board No.

NA Other ID FO15-001 Date 12/20/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-005273 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA Year Built 1972

Repaired, Replaced, or Replacement REPAIRED
7. Description of Work REPAIR CLASS 2 AUXILIARY FEEDWATER SYSTEM 3" VALVE AFW-4A DUE TO IMPROPER SEATING.
8. Tests conducted Hydrostatic

[

Other D Pneumatic Nominal Operating Pressure

=V Pressure 1040 psi Test Temp.

57 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached Name of Component AFW-4A ASME Code Stamped N

Exempt 1

NIS-2 (Back)

Sheet 2 of 2 Date: *12/20/2001 Name of Component:

AFW-4A Work Order Number: 01-005273 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed PXfluO-A.l 1Z n Ou

-v Date 2

0,20 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 9÷S'*

00 to / -3/OV

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, 1, N, IS, A WIS 100024 Inspector'signature National Board, State, Province, and Endorsements Date f

-/

,20 1PZ

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 23 Class 2 CONTAINMENT SPRAY
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component ICS-2B Name of Manufacturer CRANE VALVE CO.

Manufacturer Serial No.

NF National Board No.

NA Date 12/3/2001 Sheet I of 2 Unit No. 1 Work Order 01-007182 Type Code Sym. Stamp N__A Authorization No. NA Expiration Date NA Code Case NA Other Year ID Built ICS002-002 1970

Repaired, ASME
Repaired, Replaced, or Replacement REPAIRED N
7. Description of Work OPEN FOR MAINTAENANCE CLASS 2 INTERNAL CONTAINMENT SPRAY 8" VALVE ICS-2B.
8. Tests conducted Hydrostatic E

Other RI Pneumatic r-Nominal Operating Pressure FX Pressure 30 psi Test Temp.

70.4 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped Exempt 1"1 REPAIRED N

NIS-2 (Back)

Sheet 2 of 2 Date:

12/3/2001 Name of Component:

ICS-2B Work Order Number: 01-007182 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XL.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed / / 4

'f,0Jfl-Date

,20 02 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period '7--2S-9 to /-3/ -02, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions

NB7741, I, N, IS, A WIS 100024 Inspectors Signature National Board, State, Province, and Endorsements Date

/

20

_.___,20_

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 23 Class 2 CONTAINMENT SPRAY
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component ICS-2A Name of Manufacturer CRANE VALVE CO.

Manufacturer Serial No.

NF National Board No.

NA Date 12/3/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-007183 Type Code Sym. Stamp N__AA Authorization No. NA Expiration Date NA Code Case NA Other Year ID Built ICS002-001 1970

Repaired, Replaced, or Replacement REPAIRED
7. Description of Work OPEN FOR MAINTENANCE CLASS 2 INTERNAL CONTAINMENT SPRAY 8" VALVE ICS-2B.
8. Tests conducted Hydrostatic Other D--

1-1 Pneumatic 1:1 Nominal Operating Pressure IE Pressure 30 psi Test Temp.

70.4 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped N

Exempt 1

NIS-2 (Back)

Sheet 2 of 2 Date:

12/3/2001 Name of Component:

ICS-2A Work Order Number: 01-007183 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed

_.D

    • e*J L.'i 20 0 _

Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period '7-;,'5-' 0 to I-3 / -V2, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

ie, -7

.Commissions NB7741, I, N, IS, A WIS 100024 U

p oiorsSignature National Board, State, Province, and Endorsements Da te-

.20 01

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 23 Class 2 CONTAINMENT SPRAY
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component RHR-400B Name of Manufacturer CRANE COMPANY Manufacturer Serial No.

NA National Board No.

NA Date 1/14/2002 Sheet 1 of 2 Unit No. I Work Order 01-007184 Type Code Sym. Stamp NA..

Authorization No. NA Expiration Date NA Code Case NA Other Year ID Built ICS006-006 1970

Repaired, ASME
Repaired, Replaced, or Replacement REPAIRED
7. Description of Work OPEN FOR MAINTENANCE CLASS 2 INTERNAL CONTAINMENT SPRAY 6" VALVE RHR-400B DUE TO POSSIBLE DISC TO SEAT GALLING.
8. Tests conducted Hydrostatic Other Pneumatic Nominal Operating Pressure rl Pressure 144 psi Test Temp.

87 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped N

Exempt r-1

NIS-2 (Back)

Sheet 2 of 2 Date:

1/14/2002 Name of Component:

RHR-400B Work Order Number: 01-007184 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xi.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed f,

Date6MAAAM,20 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period I-2S'CD 0 to /J/,OZ

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

,2 s 7 a44
  • Commissions NB7741, I, N, IS, A WIS 100024 (5

p 5iature National Board, State, Province, and Endorsements Date

,20

  1. -1-_

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 23 Class 2 CONTAINMENT SPRAY
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component RHR-400A Name of Manufacturer CRANE COMPANY Manufacturer Serial No.

NF National Board No.

NA Date 12/20/2001 Sheet I of 2 Unit No. 1 Work Order 01-007185 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NNA Code Case NA Other Year ID Built 1C5006-005 1970 REPAIRED N

Kepalrea, Repaired, Replaced, or Replacement
7. Description of Work OPEN FOR MAINTENENCE CLASS 2 INTERNAL CONTAINMENT SPRAY SYSTEM 6" VALVE RHR-400A DUE TO POSSIBLE DISC TO SEAT GALLING.
8. Tests conducted Hydrostatic Dl Other F

Pneumatic Nominal Operating Pressure r7 Pressure 375 psi Test Temp.

341 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached Code Stamped Exempt F REPAIRED N

ICS006-005 1970

NIS-2 (Back)

Sheet 2 of 2 Date: 12/20/2001 Name of Component:

RHR-400A Work Order Number: 01-007185 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed Date 20 0A Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period

'7-1S"-00 to /-$1-t2,, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XL.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 pectors Signature National Board, State, Province, and Endorsements Date

/

20 J0

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 23 Class 2 CONTAINMENT SPRAY
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component ICS-5B Name of Manufacturer CRANE VALVE CO.

Manufacturer Serial No.

NF National Board No.

NA Date 11/9/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-007186 Type Code Sym. Stamp NAA Authorization No. NA Expiration Date NA Code Case NA Other Year ID Built ICS006-003 1970

Repaired, Replaced, or Replacement REPAIRED
7. Description of Work OPEN FOR REPAIR CLASS 2 CONTAINMENT SPRAY SYSTEM 6" VALVE ICS-5B DUE TO DISC TO SEAT GALLING.
8. Tests conducted Hydrostatic Other D D-Pneumatic Pressure D

Nominal Operating Pressure n

280 psi Test Temp.

75 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped N

Exempt F

NIS-2 (Back)

Sheet 2 of 2 Date:.

11/9/2001 Name of Component:

ICS-5B Work Order Number: 01-007186

,20 6

Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed A

&Q lT'/c,2*.

A*A*h acW*U t

Date 4

,20 0.1 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owners Report during the period 7_-_'_o to I/-'S-,

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

w o--:

Commissions NB7741, I, N, IS, A WIS 100024 National Board, State, Province, and Endorsements iignature

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson. Wisconsin 54016
4. Identification of System 23 Class 2 CONTAINMENT SPRAY
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component ICS-6B Name of Manufacturer CRANE VALVE CO.

Manufacturer Serial No.

NF National Board No.

NA Date 11/9/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-007187 Type Code Sym. Stamp NA Authorization No.

NA Expiration Date NA Code Case NA Other Year ID Built ICS006-004 1970

Repaired, Replaced, or Replacement REPAIRED
7. Description of Work OPEN FOR MAINTENANCE CLASS 2 CONTAINMENT SPRAY SYSTEM 6" VALVE ICS-6B DUE TO DISC TO SEAT GALLING.
8. Tests conducted Hydrostatic Other El El Pneumatic Nominal Operating Pressure I*

Pressure 280 psi Test Temp.

Z5 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped N

Exempt 1

NIS-2 (Back)

Sheet 2 of 2 Date:

11/9/2001 Name of Component:

ICS-6B Work Order Number: 01-007187 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed eI "a,

&JV.AnJ AAJ Date l i

,20 0O.1 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period

'7-2Y-,0 to /-JI/-0 X, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

,Commissions NB7741, I, N, IS, A WIS 100024 Date

,20 60.1 National Board, State, Province, and Endorsements V Inspector's 11gnature

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 33 Class 1 SAFETY INJECTION
5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component SI-304A Name of Manufacturer VELAN VALVE CORPORATION Manufacturer Serial No.

NF National Board No.

NA Other ID SI116-005 Date 9/7/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-013239 Type Code Sym. Stamp NA Authorization No.

NA Expiration Date NA Code Case NA Year Built 1967

Repaired, Replaced, or Replacement REPAIRED
7. Description of Work TORQUE BOLTING ON CLASS 1 SAFETY INJECTION SYSTEM 6" VALVE SI-304A DUE TO EVIDENCE OF LEAKAGE.
8. Tests conducted Hydrostatic Other F

Pneumatic Pressure D

Nominal Operating Pressure 0

psi Test Temp.

1:1 Exempt El 0 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped N

NIS-2 (Back)

Sheet 2 of 2 Date:

9/7/2001 Name of Component:

SI-304A Work Order Number: 01-013239 Da tetej 20 ~

Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed Date 20 C.

Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7t.4"O to /-3/-#;L, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

A ?-3" 7~t",Commissions NB7741, 1, N, IS, A WIS 100024 National Board, State, Province, and Endorsements I"

Inspecr's Signature

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 35 Class 2 CHEMICAL AND VOLUME CONTROL
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section X1 Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Manufacturer GRINNELL FIRE PROTECTION SYSTEMS Manufacturer Serial No.

NF National Board No.

NA Date 8/20/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-013438 Type Code Sym. Stamp N.A Authorization No.

NA Expiration Date NA Code Case NA Other Year ID Built CS033-005 1973

Repaired, Replaced, or Replacement REPAIRED
7. Description of Work TORQUE BOLTING ON CLASS 2 CHEMICAL AND VOLUME CONTROL SYSTEM 3" VALVE CVC-4C DUE TO BODY TO BONNET LEAK.
8. Tests conducted Hydrostatic Other F

1I-Pneumatic Pressure L]

Nominal Operating Pressure El 23 psi Test Temp.

11_5 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached Name of Component CVC-4C ASME Code Stamped N

Exempt El

NIS-2 (Back)

Sheet 2 of 2 Date:

8/20/2001 Name of Component:

CVC-4C Work Order Number: 01-013438 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section Xl.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed 1CA AAX.L.A

,7T-t CJ*

Date 20 6,20 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 74--'O0 to /-3/-D2-, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, 1, N, IS, A WIS 100024 Inspectors Signature National Board, State, Province, and Endorsements Date 20 O;

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 34 Class 2 RESIDUAL HEAT REMOVAL
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component RHR-100B Name of Manufacturer CRANE VALVE CO.

Manufacturer Serial No.

NF National Board No.

NA Date 11/21/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-014566 Type Code Sym. Stamp N A Authorization No. NA Expiration Date NA Code Case NA Other Year ID Built AC010-008 1972

Repaired, Replaced, or Replacement REPAIRED
7. Description of Work OPEN FOR REPAIR CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM 8" VALVE RHR-100B.
8. Tests conducted Hydrostatic Other D Pneumatic 1

Nominal Operating Pressure El Pressure 114 psi Test Temp.

87 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped N

Exempt LI

NIS-2 (Back)

Sheet 2 of 2 Date:.11/21/2001 Name of Component:

RHR-100B Work Order Number: 01-014566 Date

/

20 2

Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed

__.JA CA)Jt Date

.20 0 ca, Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 74So-'

to 3/ 1'- 2-, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions NB7741, I, N, IS, A WIS 100024 National Board, State, Province, and Endorsements a.nspector's'gnature

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
4. Identification of System 34 Class 2 RESIDUAL HEAT REMOVAL
5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Component RHR-100A Name of Manufacturer CRANE VALVE COMPANY Manufacturer Serial No.

NF National Board No.

NA Date 11/27/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-014567 Type Code Sym. Stamp NA Authorization No.

NA Expiration Date NA Code Case NA Other Year ID Built AC010-007 1972

Repaired, Replaced, or Replacement REPAIRED
7. Description of Work REPAIR CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM 8" VALVE RHR-100A.
8. Tests conducted Hydrostatic Other 1:

LII Pneumatic Pressure 340 psi Nominal Operating Pressure L

Test Temp.

189 deg. F

9. Remarks NOT APPLICABLE.

Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped N

Exempt 1

NIS-2 (Back)

Sheet 2 of 2 Date:.11/27/2001 Name of Component:

RHR-100A Work Order Number: 01-014567 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed 1k:

  • W A

0 LN 111

flh1, Date 20 0.__

Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period '7-;S'00 to I 3/'-0Z, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

A

ý nCommissions NB7741, I, N, IS, A WIS 100024 Inspe or's Signature National Board, State, Province, and Endorsements Date - **.

20

-0

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI

1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson. Wisconsin 54016
4. Identification of System 35 Class 2 CHEMICAL AND VOLUME CONTROL
5. (a) Applicable Construction Code NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
6. Identification of Components Repaired or Replaced and Replacement Components Name of Manufacturer AJAX IRON WORKS Manufacturer Serial No.

6577 National Board No.

NA Other ID 00077 Date 9/5/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-014609 Type Code Sym. Stamp N.A Authorization No.

NA Expiration Date NA Code Case NNA Year Built 1967

Repaired, Replaced, or Replacement REPAIRED
7. Description of Work REPAIR CLASS 2 CHEMICAL AND VOLUME CONTROL SYSTEM CHARGING PUMP 1C (SUCTION VALVE REPAIR).
8. Tests conducted Hydrostatic Other R

Pneumatic 1:

Nominal Operating Pressure El Pressure 20 psi Test Temp.

112 deg. F

9. Remarks NOT APPLICABLE Applicable Manufacturer's Data Reports to be Attached Name of Component APCH-1C ASME Code Stamped N

Exempt El

NIS-2 (Back)

Sheet 2 of 2 Date:

9/5/2001 Name of Component:

APCH-1C Work Order Number: 01-014609 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.

Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No.

NA Expiration Date NA Signed e*. 640-*pao*

Date

,20 0 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 1-2r-0 0 to

/__3_-_

2_, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

lns Jtr Commissions NB7741, I, N, IS, A WIS 100024 Inspector's Signature National Board, State, Province, and Endorsements Date

/

20 0

,