{{#Wiki_filter:FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI
- 1. Owner Wisconsin Public Service Corporation Date 12/3/2001 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001 Sheet 1 of 2
- 2. Plant Kewaunee Nuclear Power Plant Unit No. I N490 HWY 42 Kewaunee, WI 54216-9511 Work Order 01-014720
- 3. Work Performed By Nuclear Management Company, LLC Type Code Sym. Stamp
_A_ 700 First Street, Hudson, Wisconsin 54016 Authorization No. NA
- 4. Identification of System 33 Class 1 SAFETY INJECTION Expiration Date NA
- 5. (a) Applicable Construction Code B16.5-1967 Code Case NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
- 6. Identification of Components Repaired or Replaced and Replacement Components
- Repaired, ASME Name of Name of Manufacturer National Other Year Replaced, or Code Component Manufacturer Serial No.
Board No. ID Built Replacement Stamped SI-304A VELAN VALVE NF NA S1116-005 1967 REPAIRED N CORPORATION
- 7. Description of Work OPEN FOR INSPECTION AND SEAL WELDING OF BONNET TO BODY CLASS 1 6" SAFETY INJECTION VALVE SI 304A.
- 8. Tests conducted Hydrostatic
[- Pneumatic F Nominal Operating Pressure E-Exempt F' Other Pressure 2240 psi Test Temp. 551 deg. F
- 9. Remarks NOT APPLICABLE.
Applicable Manufacturer's Data Reports to be Attached
NIS-2 (Back) Sheet 2 of 2 Date: - 12/3/2001 Name of Component: SI-304A Work Order Number: 01-014720 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed ýLa)g-**I*#'/*O7 LI/' Date,*3_ 20 0.), Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-;r-00 to /-31/-OZ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. 4 l
- Lýýý---
Commissions NB7741, 1, N, IS, A WIS 100024 Inspector4s Signature National Board, State, Province, and Endorsements Date 20 20 7
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI
- 1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
- 2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
- 3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson. Wisconsin 54016
- 4. Identification of System 34 Class 2 RESIDUAL HEAT REMOVAL
- 5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Component RHR-8B Name of Manufacturer FISHER CONTINENTAL Manufacturer Serial No.
141551 National Board No. NA Date 11/8/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-016057 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA Other Year ID Built AC012-002 1972
- Repaired, Replaced, or Replacement REPAIRED
- 7. Description of Work REPAIR LOOSE NUT ON CLASS 2 RESIDUAL HEAT REMOVAL SYSTEM 8" VALVE RHR-8B SHAFT COVER.
- 8. Tests conducted Hydrostatic El Other D Pneumatic Pressure Nominal Operating Pressure psi Test Temp.
El Exempt El deg. F
- 9. Remarks NOT APPLICABLE.
Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped N
NIS-2 (Back) Sheet 2 of 2 Date: " 11/8/2001 Name of Component: RHR-8B Work Order Number: 01-016057 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XL. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed e &
- LgAnw, Date 20 CA Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-Sir-/V to /-3/1-0
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions NB7741, I, N, IS, A WIS 100024 sector's gnature National Board, State, Province, and Endorsements Date 20 V
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI
- 1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay. WI 54307-9001
- 2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
- 3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
- 4. Identification of System 33 Class 1 SAFETY INJECTION
- 5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Component Sl-W6S Name of Manufacturer TEXAS PIPE BENDING Manufacturer Serial No.
NA National Board No. NA Other ID NA Date 11/9/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-016342 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA Year Built 1967 REPAIRED N
- Kepalrea, R~epaired, Replaced, or Replacement
- 7. Description of Work REPAIR BY LIGHT FILING CLASS 1 SAFETY INJECTION SYSTEM 2" SOCKET WELD SI-W6S DUE TO LINEAR INDICATION.
- 8. Tests conducted Hydrostatic Other E]
D-1 Pneumatic Pressure Nominal Operating Pressure psi Test Temp. E]7 Exempt deg. F
- 9. Remarks NOT APPLICABLE.
Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped REPAIRED N 1967
NIS-2 (Back) Sheet 2 of 2 Date: 11/9/2001 Name of Component: Sl-W6S Work Order Number: 01-016342 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed d & I~vkt J.MN44#l 6&4nMNCul.hy pAU Date ,20
- L Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-,.ZS-Ov to /-31-0; L, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. 74nsp Commissions NB7741, I, N, IS, A WIS 100024 ectorsvignature National Board, State, Province, and Endorsements Date '20 OC--
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI
- 1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
- 2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
- 3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
- 4. Identification of System 36 Class 1 REACTOR COOLANT
- 5. (a) Applicable Construction Code ASME III CLASS A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Component PZR Name of Manufacturer WESTINGHOUSE Manufacturer Serial No.
1151 National Board No. 68-23 Other ID 00041 Date 12/3/2001 Sheet I of 2 Unit No. 1 Work Order 01-016448 Type Code Sym. Stamp NAA Authorization No. NA Expiration Date NA Code Case NA Year Built 1968
- Repaired, Replaced, or Replacement REPLACEMENT
- 7. Description of Work REPAIR CLASS 1 REACTOR COOLANT SYSTEM PRESSURIZER MANWAY INCLUDING REPLACING 7 BOLTS.
- 8. Tests conducted Hydrostatic Other D]
F Pneumatic [l Pressure 2240 psi Nominal Operating Pressure =V Test Temp. [551 deg. F
- 9. Remarks NOT APPLICABLE.
Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped Y Exempt 1
NIS-2 (Back) Sheet 2 of 2 Date: - 12/3/2001 Name of Component: PZR Work Order Number: 01-016448 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed /(Y4* /3AUA 'JMOMKLb I" O*A) Date L 4 ,20 06 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 14S-$%OD to /-/-3 2, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions NB7741, I, N, IS, A WIS 100024 ature National Board, State, Province, and Endorsements Date -20 A,7-
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI
- 1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, Wl 54307-9001
- 2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, Wl 54216-9511
- 3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
- 4. Identification of System 36 Class 1 REACTOR COOLANT
- 5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Manufacturer ITT GRINNELL VALVE COMPANY Manufacturer Serial No.
NA National Board No. NA Other ID NA Date 11/26/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-016564 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA Year Built 1967
- Repaired, Replaced, or Replacement REPLACEMENT
- 7. Description of Work REPLACED CLASS 2 REACTOR COOLANT SYSTEM 6" HANGER RC-H9 TAIL ROD AND MODIFIED SUPPORT DUE TO DEFORMED SWAY STRUT.
- 8. Tests conducted Hydrostatic LI Other Pneumatic r*
Pressure Nominal Operating Pressure psi Test Temp.
- 9. Remarks NOT APPLICABLE.
Applicable Manufacturer's Data Reports to be Attached Name of Component RC-H9 ASME Code Stamped N E] deg. F Exempt [*]
NIS-2 (Back) Sheet 2 of 2 Date:.11/26/2001 Name of Component: RC-H9 Work Order Number: 01-016564 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section X1. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed 79J .T. ,M 1 t n ) i kl*-A' Date 20 0 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7oAS'-O") to /-3/-2*, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. .Commissions NB7741, I, N, IS, A WIS 100024 Date / 20 National Board, State, Province, and Endorsements 61 Inspeco Signature
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl
- 1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
- 2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
- 3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
- 4. Identification of System 33 Class 2 SAFETY INJECTION
- 5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Component RSI-H80 Name of Manufacturer ITT GRINNELL VALVE COMPANY Manufacturer Serial No.
NA National Board No. NA Other ID NA Date 10/29/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-016566 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA Year Built 1967
- Repaired, Replaced, or Replacement REPAIRED
- 7. Description of Work REPAIR CLASS 2 SAFETY INJECTION SYSTEM 2" HANGER RSI-H80 DUE TO LOOSE NUT ON PIPE CLAMP BOLT.
- 8. Tests conducted Hydrostatic Other F
I-Pneumatic Pressure LI Nominal Operating Pressure psi Test Temp. D1 deg. F
- 9. Remarks NOT APPLICABLE.
Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped N Exempt El N
NIS-2 (Back) Sheet 2 of 2 Date:.10/29/2001 Name of Component: RSI-H80 Work Order Number: 01-016566 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed 7*L*!X-C. Date m ,20 Q Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period "7-.'2io0 to /'tZ, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
- 1. -'
Commissions NB7741, I, N, IS, A WIS 100024 Inspector's nature National Board, State, Province, and Endorsements Date / ,20 OX.
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI
- 1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
- 2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
- 3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
- 4. Identification of System 05A Class 2 FEEDWATER
- 5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Component FW-80B Name of Manufacturer ROCKWELL INTERNATIONAL Manufacturer Serial No.
NF National Board No. NA Other ID FO13-002 Date 12/5/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-016713 Type Code Sym. Stamp N.A. Authorization No. NA Expiration Date NA Code Case NA Year Built 1972
- Repaired, ASME
- Repaired, Replaced, or Replacement REPAIRED
- 7. Description of Work REPAIR BY GRINDING LINEAR INDICATIONS ON CLASS 2 FEEDWATER SYSTEM 1" VENT VALVE FW-80B NOZZLE I.D. INCLUDING REMOVING EXISTING 1" NOZZLE AND REPLACING WITH 1.9" DIAMETER NOZZLE.
- 8. Tests conducted Hydrostatic l
Other n Pneumatic Pressure Nominal Operating Pressure psi Test Temp. 1:1 Exempt deg. F
- 9. Remarks NOT APPLICABLE.
Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped N
NIS-2 (Back) Sheet 2 of 2 Date: 12/5/2001 Name of Component: FW-80B Work Order Number: 01-016713 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed e.& A th Oa4L T?.WMA.-/u Date ,20 bl,, Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period '7-';'P-" to /- 31-0 X, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions NB7741, I, N, IS, A WIS 100024 Inspector's gnature National Board, State, Province, and Endorsements Date / 20
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI
- 1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
- 2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511
- 3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
- 4. Identification of System 05A Class 2 FEEDWATER
- 5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Component FW-80A Name of Manufacturer ROCKWELL INTERNATIONAL Manufacturer Serial No.
NF National Board No. NA Other ID F013-001 Date 12/4/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-016714 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA Year Built 1972 REPAIRED N
- Repaired, ASM
- Repaired, Replaced, or Replacement
- 7. Description of Work REPAIR BY GRINDING LINEAR INDICATIONS ON CLASS 2 FEEDWATER SYSTEM 1" VENT VALVE NOZZLE I.D.
- 8. Tests conducted Hydrostatic Other R
Pneumatic Pressure Nominal Operating Pressure psi Test Temp.
- 9. Remarks NOT APPLICABLE.
Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped D: deg. F Exempt [*] REPAIRED N 1972
NIS-2 (Back) Sheet 2 of 2 Date: 12/4/2001 Name of Component: FW-80A Work Order Number: 01-016714 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XL. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed20 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period TS"- to l-J,/3 - 2., and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. S.Commissions NB7741, I, N, IS, A WIS 100024 Inspectis Signature National Board, State, Province, and Endorsements Date / 20 0_2-
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section Xl
- 1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
- 2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
- 3. Work Performed By Nuclear Managqement Company, LLC 700 First Street, Hudson, Wisconsin 54016
- 4. Identification of System 05A Class 2
FEEDWATER
- 5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Component FW-W55BC Name of Manufacturer TEXAS PIPE BENDING Manufacturer Serial No.
356469 National Board No. NA Other ID NA Date 12/4/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-016715 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA Year Built 1969
- Repaired, Replaced, or Replacement REPAIRED
- 7. Description of Work REPAIR BY GRINDING, INDICATIONS ON CLASS 2 FEEDWATER SYSTEM 8" AUXILIARY FEEDWATER NOZZLE I.D.
- 8. Tests conducted Hydrostatic F]
Other 1"- Pneumatic Pressure D Nominal Operating Pressure psi Test Temp.
- 9. Remarks NOT APPLICABLE.
Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped N El deg. F Exempt El
NIS-2 (Back) Sheet 2 of 2 Date: 12/4/2001 Name of Component: FW-W55BC Work Order Number: 01-016715 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed Q.--- A TWA Date ,20 O.*_ Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period,1-X-0'? to /-3fr-PZ, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions
- NB7741, I, N, IS, A WIS 100024 nspector'sSi nature National Board, State, Province, and Endorsements Date
/ 20 OP
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI
- 1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
- 2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
- 3. Work Performed By Nuclear Management Company. LLC 700 First Street, Hudson. Wisconsin 54016
- 4. Identification of System 36 Class 1 REACTOR COOLANT
- 5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Manufacturer ITT GRINNELL VALVE COMPANY Manufacturer Serial No.
NA National Board No. NA Other ID NA Date 11/1/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-016849 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA Year Built 1967
- Repaired, ASME
- Repaired, Replaced, or Replacement REPAIRED N
- 7. Description of Work REPAIR CLASS 1 REACTOR COOLANT SYSTEM 2" HANGER RCVC-H48 DUE TO LOOSE NUT ON THE CLEVIS BOLT.
- 8. Tests conducted Hydrostatic Other 1-D Pneumatic r
Pressure Nominal Operating Pressure psi Test Temp. F"] Exempt El deg. F
- 9. Remarks NOT APPLICABLE.
Applicable Manufacturer's Data Reports to be Attached Name of Component RCVC-H48 ASME Code Stamped REPAIRED N
NIS-2 (Back) Sheet 2 of 2 Date: " 11/1/2001 Name of Component: RCVC-H48 Work Order Number: 01-016849 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed Date 20 6. Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-4.'-r'O to /-3/-12 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions NB7741, I, N, IS, A WIS 100024 pect Signature National Board, State, Province, and Endorsements Date 20 ,,,2.-
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI
- 1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
- 2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
- 3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
- 4. Identification of System 36 Class 1
REACTOR COOLANT
- 5. (a) Applicable Construction Code B31.1-1967 (b) Applicable Edition of Section X1 Utilized for Repairs or Replacements 1989
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Manufacturer ITT GRINNELL VALVE COMPANY Manufacturer Serial No.
NA National Board No. NA Other ID NA Date 11/1/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-016849 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA Year Built 1967
- Repaired, ASME
- Repaired, Replaced, or Replacement REPAIRED N
- 7. Description of Work REPAIR CLASS 1 REACTOR COOLANT SYSTEM 2" HANGER RCVC-H49 DUE TO LOOSE NUT ON THE UPPER SPRING CAN SUPPORT.
- 8. Tests conducted Hydrostatic Other L]
FI Pneumatic Pressure -- I Nominal Operating Pressure psi Test Temp. n-Exempt E] deg. F
- 9. Remarks NOT APPLICABLE.
Applicable Manufacturer's Data Reports to be Attached Name of Component RCVC-H49 ASME Code Stamped REPAIRED N
NIS-2 (Back) Sheet 2 of 2 Date: " 11/1/2001 Name of Component: RCVC-H49 Work Order Number: 01-016849 Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed Q:)A* 7-ed t4 Date _h,20 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-ASrtZ to /-31-19 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions NB7741, I, N, IS, A WIS 100024 IFns i r National Board, State, Province, and Endorsements Dt spector's .2n___re Date
- -JJ/
20 O*
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI
- 1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
- 2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee, WI 54216-9511
- 3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
- 4. Identification of System 33 Class 1
SAFETY INJECTION
- 5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Component SI-304B Name of Manufacturer VELAN VALVE CORPORATION Manufacturer Serial No.
NF National Board No. NA Other ID S1116-006 Date 12/3/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-016851 Type Code Sym. Stamp NA Authorization No. NA Expiration Date NA Code Case NA Year Built 1967
- Repaired, Replaced, or Replacement REPLACEMENT
- 7. Description of Work SEAL WELD BODY TO BONNET ON CLASS 1 SAFETY INJECTION SYSTEM 6" VALVE SI-304B DUE TO BODY TO COVER LEAK INCLUDING REPLACEMENT OF 3 VALVE BONNET STUDS.
- 8. Tests conducted Hydrostatic Other D D-1 Pneumatic 1
Nominal Operating Pressure E Pressure 2240 psi Test Temp. 551 deg. F
- 9. Remarks NOT APPLICABLE.
Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped N Exempt
NIS-2 (Back) Sheet 2 of 2 Date: ' 12/3/2001 Name of Component: SI-304B Work Order Number: 01-016851 Certificate of Compliance We Certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code Section XI. Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed 19X"A./'fP/ fMM"*Z
- W1'I*
Date 4 20 Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period 7-24,*OV to / 0 2., and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions NB7741, I, N, IS, A WIS 100024 4sp odignature National Board, State, Province, and Endorsements Date / ,20 -,1-
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENT As Required by the Provisions of the ASME Code Section XI
- 1. Owner Wisconsin Public Service Corporation 700 North Adams P.O.Box 19001 Green Bay, WI 54307-9001
- 2. Plant Kewaunee Nuclear Power Plant N490 HWY 42 Kewaunee. WI 54216-9511
- 3. Work Performed By Nuclear Management Company, LLC 700 First Street, Hudson, Wisconsin 54016
- 4. Identification of System 33 Class 2 SAFETY INJECTION
- 5. (a) Applicable Construction Code B16.5-1967 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989
- 6. Identification of Components Repaired or Replaced and Replacement Components Name of Component SI-5A Name of Manufacturer ANCHOR VALVE COMPANY Manufacturer Serial No.
9193-3/70 National Board No. NA Other ID S1009-001 1970 IPAIU N Date 11/23/2001 Sheet 1 of 2 Unit No. 1 Work Order 01-016868 Type Code Sym. Stamp NAA Authorization No. NA Expiration Date NA Code Case NA Year Built
- Repaired, AMI Repairedl, Replaced, or Replacement
- 7. Description of Work OPEN FOR REPAIR CLASS 2 SAFETY INJECTION SYSTEM 6" VALVE SI-5A TO REPLACE DAMAGED STEM.
- 8. Tests conducted Hydrostatic Other n
Pneumatic r] Nominal Operating Pressure E Pressure 10 psi Test Temp. LO deg. F
- 9. Remarks NOT APPLICABLE.
Applicable Manufacturer's Data Reports to be Attached ASME Code Stamped Exempt L' RE PAIRED.L IN S1009-001 1970
NIS-2 (Back) Sheet 2 of 2 Date: 11/23/2001 Name of Component: SI-5A Work Order Number: 01-016868 Date /
- ,20 0 2-Certificate of Compliance We Certify that the statements made in the report are correct and this REPAIRED conforms to the rules of the ASME Code Section XI.
Repair or Replacement Type Code Symbol Stamp NA Certificate of Authorization No. NA Expiration Date NA Signed )ODeW __* e. 6A 'Ln Date 6 n 20 0_.. Owner or Owner's Designee, Title Certificate of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by Hartford Steam Boiler Inspection and Ins. Co. of Hartford, CT have inspected the components described in the Owner's Report during the period '7-4?,5ov to /-3 (-O Z, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Alnsp-- Commissions
- NB7741, I, N, IS, A WIS 100024 Inspector's ignature National Board, State, Province, and Endorsements
ATTACHMENT 7 Letter from T. Coutu (NMC) To Document Control Desk (NRC) Dated February 22, 2002 Examination Summary for Scheduled and Augmented Inservice Inspection (ISI) Program
NUCLEAR MANAGEMENT COMPANT, LLC KEWAUNEE NUCLEAR POWER PLANT 3RD INTERVAL: 3RD PERIOD: 1ST OUTAGE 2001 EXAMINATION
SUMMARY
INTRODUCTION An Inservice Inspection (ISI) Program (Scheduled and Augmented) was performed at the Kewaunee Nuclear Power Plant from March 27, 2001 through September 12, 2001 (Non Refueling Outage), September 19, 2001 through December 4, 2001 (Closing of G1 following Refueling Outage) and December 6, 2001 by Kewaunee Nuclear Power Plant and Lambert, MacGill, and Thomas, Inc.(LMT) examination personnel. Examinations were performed to satisfy the requirements of: "* ASME Boiler and Pressure Vessel Code Section XI 1989 Edition "* ASME Boiler and Pressure Vessel Code Section XI 1995 Edition 1996 Addenda Appendix VIII Performance Demonstration for Ultrasonic Examination Systems as required by Code of Federal Regulations 10CFR50.55 a(g)(6)(ii)(c) and Nuclear Regulatory Commission 10CFR Part 50 Federal Register/Vol.64, Number 183/September 22, 1999/Rules and Regulations "* United States Nuclear Regulatory Commission IE Bulletin 79-13 "* United States Nuclear Regulatory Commission Generic Letter 88-05 The Inservice Inspection Program Plan and Augmented Inspection Program Plan located under Tab C was prepared by Nuclear Management Company, LLC - Kewaunee Nuclear Power Plant for the 3rd Interval: 3rd Period: 1 st Outage as identified in the Kewaunee Nuclear Power Plant Third 10-Year Inservice Inspection (ISI) Program 1994-2004. Examinations during this Refueling Outage were performed to start the 3rd Interval: 3rd Period Examination Requirements of ASME Boiler and Pressure Vessel Code Section XI 1989 Edition and Kewaunee Nuclear Power Plant Third 10-Year Inservice Inspection (ISI) Program 1994-2004. The following items were examined: "* Reactor Vessel Closure Head Flange Weld "* Reactor Vessel Closure Head Studs, Nuts,Washers and Control Rod Drive Mechanisms "* Pressurizer Circumferential and Longitudinal Welds "* Steam Generator Head Circumferential Weld, Nozzle Inside Radius Sections and Nozzle To Shell Weld Page 1 of 5
"* Reactor Coolant Pump Main Flange Bolting and No. 1 Seal Housing Bolting "* Seal Water Injection Filter Shell Circumferential Weld "* Letdown Heat Exchanger Head Circumferential Weld "* Charging Pump Pulsation Dampener Head Circumferential Weld "* Class 1 Valve Bodies "* Class 1 Piping Integrally Welded Attachment "* Class 1 and Class 2 Piping Welds ", Class 2 Safety Injection Pump Casing Weld and Welded Attachments "* Class 2 Piping Integrally Welded Attachments "* Class 1, Class 2 and Class 3 Piping and Component Supports and Hangers "* Class 1 and Class 2 Reactor Vessel Conoseal Bolting, Pressurizer Manway Bolting, Flange Bolting and Valve Bonnet Bolting "* Class 1 System Leakage Test "* Class 2 and Class 3 System Inservice and Functional System Pressure Tests EXAMINATIONS The examinations performed were in accordance with an approved Inservice Inspection Program Plan located under Tab C of the final report. Examination Procedures were approved prior to the start of examinations and certification documents relative to personnel, equipment and materials were reviewed and determined to be satisfactory. Some of the arrangements and details of the Kewaunee Nuclear Power Plant Components and Piping Systems were designed and fabricated before ASME Boiler and Pressure Vessel Code Section XI Code requirements were established. Examinations performed were intended to examine 100% of the required surface or volume. In some cases, examinations were limited by geometric, metallurgical or design/access restrictions. In each case, the occurrence and cause of the limitation was documented. In all cases the maximum amount achievable was examined. Witnessing and surveillance of the examinations were conducted by: Hartford Steam Boiler Inspection and Insurance Company. RESULTS Examinations resulted with the following Recordable Indications being noted on the basis of procedure recording criteria, which are generally more restrictive than specified ASME Boiler and Pressure Vessel Code Section XI Acceptance Standards. Page 2 of 5
Recordable Indications detected during the 2001 Refueling Outage are listed in Table 1 with a brief summary following. Specific data relative to all Recordable Indications and their dispositions by either corrective measures or acceptance by ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Acceptance Criteria, Repair/Replacement or Evaluation are located in Tab F of the Final Report. TABLE 1 TYPE OR LOCATION OF RECORDABLE INDICATION (RI) "* Reactor Vessel Closure Head Flange Weld "* Steam Generator Circumferential Head Weld "* Seal Water Injection Filter Shell Weld "* Piping Integrally Welded Attachment "* Piping Circumferential Butt Weld "* Piping Socket Weld "* Reactor Vessel Conoseal Bolting "* RC Pump No. 1 Seal Housing Bolting "* Pressurizer Manway Bolting "* Component Supports and Hangers "* Valve Bonnet Bolting "* Valve Bonnet Bolting "* System Pressure Tests METHOD Surface (MT) Volumetric (UT) Volumetric (UT) Surface (PT) Surface (PT) Surface (PT) Visual (VT-3) Visual (VT-1) Visual (VT-3) Visual (VT-3) Visual (VT-1) Visual (VT-3) Visual (VT-2) NO. OF RI'S 1 Weld 1 Weld 1 Weld 1 Weld 1 Weld 1 Weld 1 Conoseal 1 Pump 1 Manway 31 Supports 1 Valve 6 Valves 51 Items
- 1. A 0.125" Long Linear Indication was recorded on the Reactor Vessel Closure Head Flange Weld RV-W12 during performance of Magnetic Particle Examination. This Linear Indication was Acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWB-3510-3.
- 2. A spot indication on Steam Generator 1B Circumferential Head Weld SG-W9 was recorded during performance of Ultrasonic Examination. This Ultrasonic Spot Indication was Acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWC-3510-1.
Page 3 of 5
- 3. 5 Laminar Indications combined into 4 laminar indications to due proximity of Indications were recorded on Seal Water Injection Filter 1A Circumferential Shell Weld AFSI-W1 during performance of Ultrasonic Examinations. These Laminar Indications were Acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWC-3510-2 and were typical of Laminations recorded on Seal Water Injection Filters 1 A and 1 B during Refueling Outages 1982, 1986, 1988, 1992 and 1998.
4.3 rounded Indications 0.0625", 0.125" and 0.1875" in diameter were recorded on 2" Piping Integrally Welded Attachment RSI-H72 during performance of Liquid Penetrant Examinations. These 3 Rounded Indications were Acceptable per ASME Boiler and Pressure Vessel Code Section III 1989 Edition Section NC-5352(b).
- 5. A 0.125" long Linear Indication and a 0.125" Rounded Indication were recorded on 6" Circumferential Butt Weld ICS-W43 during performance of Liquid Penetrant Examinations.
The 0.125" Long Linear Indication was Acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWB-3514-2. The 0.125" Rounded Indication was Acceptable per ASME Boiler and Pressure Vessel Code Section III 1989 Edition Section NC-5352.
- 6. A 0.55" long Linear Indication on 2" Socket Weld SI-W6S was recorded during performance of Liquid Penetrant Examinations. This Linear Indication was Unacceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWB-3514-2. The Linear Indication was removed under Work Order 01-016342 by light filing with a jewelers file, reexamined and Accepted with No Indications.
- 7. Visual (VT-1, VT-2 and VT-3) Indications recorded on Reactor Vessel Conoseal Bolting, Reactor Coolant Pump No. 1 Seal Housing Bolting, Pressurizer Manway Bolting, Valve Bonnet Bolting, Piping Supports and Hangers and during System Pressure Tests were: (1)
Evaluated and Accepted or (2) Repaired, Reexamined and Accepted by: Nuclear Management Company, LLC - Maintenance, Quality Control, Engineering and Technical Support or Inservice Inspection Personnel and reviewed by the Authorized Nuclear Inservice Inspector. Page 4 of 5
SUMMARY
An Inservice Inspection Program Plan was performed at the Kewaunee Nuclear Power Plant from March 27, 2001 through September 12, 2001 (Non Refueling Outage) and September 19, 2001 through December 4, 2001 (Closing of G1 following Refueling Outage) and December 6, 2001. Examinations were performed as scheduled in the Kewaunee Nuclear Power Plant Third 10-Year Inservice Inspection (ISI) Program 1994-2004 to start examinations for the 3rd Interval; 3rd Period. A total of 98 Recordable Indications were detected. All Recordable Indications were corrected or accepted by ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Acceptance Criteria, Repair/Replacement or Evaluation. Phillip E. Bukes Date Engineering and Technical Support Inservice Inspection Program Owner Page 5 of 5
ATTACHMENT 8 Letter from T. Coutu (NMC) To Document Control Desk (NRC) Dated February 22, 2002 Examination Summary for Inservice Inspection (ISI) Class MC Program
NUCLEAR MANAGEMENT COMPANY, LLC KEWAUNEE NUCLEAR POWER PLANT 1ST INTERVAL: 2ND PERIOD: 1ST OUTAGE 2001 EXAMINATION
SUMMARY
INTRODUCTION An Inservice Inspection (ISI) Program for the Class MC Reactor Building Containment Vessel was performed at the Kewaunee Nuclear Power Plant from September 18, 2001 through December 4, 2001 (Closing of G1 following Refueling Outage) by Kewaunee Nuclear Power Plant and Lambert, MacGill and Thomas Inc. examination personnel. Examinations were performed to satisfy the requirements of: - ASME Boiler and Pressure Vessel Code Section XI 1992 Edition up to and including 1992 Addenda The Inservice Inspection Program Plan located under Tab C was prepared by Nuclear Management Company, LLC - Kewaunee Nuclear Power Plant for the 1 st Interval: 2nd Period: 1 st Outage as identified in the Kewaunee Nuclear Power Plant First 10-Year Inservice Inspection (ISI) Program 1996-2006. The following items were examined for the Class MC Reactor Building Containment Vessel: "* Accessible Surface Areas "* Longitudinal Welds and Circumferential Welds "* Sleeve to Bellows Welds "* Flange Welds "* Seals and Gaskets "* Moisture Barriers "* Dissimilar Metal Welds "* Bolted Connections "* Containment Penetration Bellows "* Airlocks EXAMINATIONS The examinations performed were in accordance with an approved Inservice Inspection Program Plan located under Tab C of the final report. Examination Procedures were approved Page 1 of 3
prior to the start of examinations and certification documents relative to personnel, equipment and materials were reviewed and determined to be satisfactory. Some of the arrangements and details of the Kewaunee Nuclear Power Plant Components and Piping Systems were designed and fabricated before ASME Boiler and Pressure Vessel Code Section XI Code requirements were established. Examinations performed were intended to examine 100% of the required surface or volume. In some cases, examinations were limited by geometric, metallurgical or design/access restrictions. In each case, the occurrence and cause of the limitation was documented. In all cases the maximum amount achievable was examined. Witnessing and surveillance of the examinations were conducted by: Hartford Steam Boiler Inspection and Insurance Company. RESULTS Examinations resulted with the following Recordable Indications being noted on the basis of procedure recording criteria, which are generally more restrictive than specified ASME Boiler and Pressure Vessel Code Section XI Acceptance Standards. Recordable Indications detected during the 2001 Refueling Outage are listed in Table 1 with a brief summary following. Specific data relative to all Recordable Indications and their dispositions by either corrective measures or acceptance by ASME Boiler and Pressure Vessel Code Section XI 1992 Edition up to and including 1992 Addenda Acceptance Criteria, Repair/Replacement or Evaluation are located in Tab F of the Final Report. TABLE 1 TYPE OR LOCATION OF RECORDABLE INDICATION (RI) METHOD NO. OF RI'S Reactor Building Containment Vessel General Visual 11 Plates Reactor Building Containment Vessel VT-3 5 Plates Moisture Barriers Reactor Building Containment Vessel VT-i 1 Bolt Emergency Airlock Page 2 of 3
- 1. General Visual Indication consisting of a 4" x 8" Surface Defect was recorded on Plate 155. This Surface Defect was previously recorded and accepted in 1998 and showed no change in dimension or surface condition during the 2001 Refueling Outage.
- 2. General Visual Indication consisting of a slight inward bulge on Plates 74, 75 and 83 was recorded. The slight inward bulge was evaluated by Engineering and Accepted under Kewaunee Nuclear Power Plant Specification TS-1052, Addendum No. 4, Item No. 19 Section 10.3 - Shell Tolerance.
- 3. General Visual Indication consisting of slight Outward Bulges on Plates 144, 145, 146, 147 and 148 were recorded. The slight Outward Bulges were evaluated and Accepted by Engineering Analysis.
- 4. General Visual Indications consisting of Weld Deposits on Plate 62 and Arc Strikes on Plate 99 were recorded and are Acceptable per ASME Boiler and Pressure Vessel Code Section XI 1992 Edition 1992 Addenda.
- 5. VT-3 Indications consisting of Lack of Bonding and Tears were recorded in the Moisture Barriers on Plates 62, 64, 65, 66 and 67 and were repaired under Work Order 01-018045.
- 6. A VT-1 Indication on an Emergency Airlock Bolt was recorded and was repaired under Work Order 01-018283.
SUMMARY
An Inservice Inspection Program for the Class MC Reactor Building Containment Vessel was performed at the Kewaunee Nuclear Power Plant from September 18, 2001 through December 4, 2001 (closing of GI following Refueling Outage). Examinations were performed as scheduled in the Kewaunee Nuclear Power Plant First 10-Year Inservice Inspection (ISI) Program 1996-2006. A total of 17 Recordable Indications were detected. All Recordable Indications were corrected and accepted by: ASME Boiler and Pressure Vessel Code Section XI 1992 Edition up to and including 1992 Addenda Acceptance Criteria, Repair/Replacement, Evaluation or Kewaunee Nuclear Power Plant Technical Specifications. Phillip E. Bukes Date Engineering and Technical Support Inservice Inspection Program Owner Page 3 of 3
ATTACHMENT 9 Letter from T. Coutu (NMC) To Document Control Desk (NRC) Dated February 22, 2002 Examination Summary for Preservice Inspection (PSI) of Steam Generators
NUCLEAR MANAGEMENT COMPANY, LLC KEWAUNEE NUCLEAR POWER PLANT REPLACEMENT STEAM GENERATORS PRESERVICE INSPECTION EXAMINATION
SUMMARY
3RD INTERVAL: 3RD PERIOD: 1ST OUTAGE 2001 INTRODUCTION A Preservice Inspection (PSI) was performed at the Kewaunee Nuclear Power Plant on the Replacement Steam Generators 1) in the Steam Generator Storage Building from June 5, 2001 through June 26, 2001 and 2) during installation in conjunction with the 2001 Refueling Outage from September 19, 2001 through December 4, 2001 (Closing of G1 following Refueling Outage) by Kewaunee Nuclear Power Plant and Lambert, MacGill, and Thomas, Inc. (LMT) examination personnel. Examinations were performed to satisfy the requirements of: "* ASME Boiler and Pressure Vessel Code Section XI 1989 Edition "* ASME Boiler and Pressure Vessel Code Section XI 1995 Edition 1996 Addenda Appendix VIII Performance Demonstration for Ultrasonic Examination Systems as required by Code of Federal Regulations 10CFR50.55a(g)(6)(ii)(c) and Nuclear Regulatory Commission 10CFR Part 50 Federal Register/Vol.64, Number 183/Septemeber 22, 1999/Rules and Regulations "* Kewaunee Nuclear Power Plant Nuclear Regulatory Commission Commitment Tracking No.95-046 "* Kewaunee Nuclear Power Plant Augmented Program for examinations performed in conjunction with Steam Generator Replacement Activities The Preservice Inspection Program Plan and Augmented Inspection Program Plan located under Tab C was prepared by Nuclear Management Company, LLC Kewaunee Nuclear Power Plant for the 3rd Interval: 3rd Period: 1st Outage and as identified in the Kewaunee Nuclear Power Plant Third 10-Year Inservice Inspection (ISI) Program 1994-2004. The following items were examined:
- Replacement Steam Generators: Tubesheet to Head Welds, Nozzle Inside Radius Sections, Nozzle to Safe End Butt Welds, Primary Side Manway Bolting, Integrally Welded Attachments, Shell Circumferential Welds, Tubesheet to Shell Welds and Class 1 Support Components
- New Class 1 Reactor Coolant Piping Welds Page 1 of 5
"* New and Replacement Class 2 Main Steam and Feedwater Piping Welds "* Reexamination of Existing Steam Generator Circumferential Welds SG-W2 and SG-Wl0 to verify previously recorded Ultrasonic Planar Indications "* Existing 16", 8" and 1" Feedwater Inside Diameter Surfaces "* Existing Steam Generator Inside Diameter Feedwater Nozzle Inner Radius and Shell Circumferential Welds "* Existing Steam Generator Class 2 Supports EXAMINATIONS The examinations performed were in accordance with an approved Preservice Inspection Program Plan located under Tab C of the final report. Examination Procedures were approved prior to the start of examinations and certification documents relative to personnel, equipment and materials were reviewed and determined to be satisfactory. Some of the arrangements and details of the Kewaunee Nuclear Power Plant Components and Piping Systems were designed and fabricated before ASME Boiler and Pressure Vessel Code Section XI Code requirements were established. Examinations performed were intended to examine 100% of the required surface or volume. In some cases, examinations were limited by geometric, metallurgical or design/access restrictions. In each case, the occurrence and cause of the limitation was documented. In all cases the maximum amount achievable was examined. Witnessing and surveillance of the examinations were conducted by: Hartford Steam Boiler Inspection and Insurance Company. Surveillance of the examinations were conducted by: United States Nuclear Regulatory Commission. RESULTS Examinations resulted with the following Recordable Indications being noted on the basis of procedure recording criteria, which are generally more restrictive than specified ASME Boiler and Pressure Vessel Code Section XI Acceptance Standards. Recordable Indications detected during the 2001 Refueling Outage are listed in Table 1 with a brief summary following. Specific data relative to all Recordable Indications and their dispositions by either corrective measures or acceptance by ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Acceptance Criteria, Repair/Replacement or Evaluation are located in Tab F of the Final Report. Page 2 of 5
TABLE 1 TYPE OR LOCATION OF RECORDABLE INDICATION (RI) "* Replacement Steam Generator Integrally Welded Attachment SG-1B-23B "* Replacement Steam Generator Tubesheet To Head Weld SG-W32 "* Replacement Steam Generator Primary Side Manway SG-lB-CLMWB "* Replacement Steam Generator Tubesheet To Shell Weld SG-W31 "* Existing Steam Generator Feedwater Nozzle Inner Radius SG-IR8 "* Existing Steam Generator Feedwater Nozzle Inner Radius SG-IR 16 "* Existing Steam Generator Circumferential Welds SG-W2 and SG-W10 "* Existing 16", 8" and 1" Feedwater Piping FW-W27BC "* Existing 16", 8" and 1" Feedwater Piping FW-W55BC METHOD Surface (MT) Volumetric (UT) Visual (VT-1) Volumetric (UT) Surface (MT) Surface(MT) & Visual (VT-1) Volumetric (UT) Surface (MT) NO. OF RI'S 1 Weld 1 Weld 1 Stud 1 Weld 1 Nozzle 1 Nozzle 2 Welds 1 ID Section Surface (MT) & Visual (VT-1) 1 ID Section
- 1. Two separate linear indications on Replacement Steam Generator lB Integrally Welded Attachment SG-1B-23B were recorded during performance of Magnetic Particle Examinations. These two linear indications due their close proximity to each other were classified as one Linear indication with a length of 0.21875". This linear indication was Acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Sections IWB-3516.1, IWB-3510.3 and IWB-3510-3.
- 2. Ultrasonic Recordable Indications at 3 separate locations on Replacement Steam Generator 1B Tubesheet to Head Weld SG-W32 were noted during performance of Manual Ultrasonic Examinations. These 3 separate Planar Indications were Acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWB-3510-1.
- 3. One Visual Indication was recorded by the VT-1 method on Replacement Steam Generator lB Primary Side Manway Stud SG-1B-CLMWB #17. Although this Primary Manway Stud was Acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Section IWB 3517. l(b), a new VT-1 Acceptable Replacement Stud was installed.
Page 3 of 5
- 4. Ultrasonic Recordable Indication at one location on Replacement Steam Generator 1B Tubesheet to Shell Weld SG-W31 was noted during performance of Manual Ultrasonic Examination. This Planar Indication was Acceptable per ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Table IWC-3510-1.
- 5. Recordable Indications on the Existing Steam Generator 1B Feedwater Nozzle Inside Radius Section SG-IR8 were recorded during Augmented Examination by Magnetic Particle. These Indications were repaired by Bechtel Corporation under Bechtel's NCR's and Kewaunee Nuclear Power Plant Work Orders as part of Replacement Steam Generator Activities.
- 6. Recordable Indications on the Existing Steam Generator 1 A Feedwater Nozzle Inside Radius Section SG-IR16 were recorded during Augmented Examinations by Magnetic Particle and Visual (VT-1) Methods. These Indications were repaired by Bechtel Corporation under Bechtel's NCR's and Kewaunee Nuclear Power Plant Work Orders as part of Replacement Steam Generator Activities.
7 & 8. Prior to severing the Existing Steam Generators and following welding the Replacement Steam Generators to the Existing Steam Generators a Manual Ultrasonic Examination was performed on existing Circumferential Shell Welds SG-W2 and SG-W1O to insure that there was no growth in the previously recorded planar indications. These Indications were recorded in 1991 for SG-W2 and in 1991 and 1996 for SG-WlO. All indications previously recorded as well as new indications recorded do to amplitude recording criteria change were Acceptable either by ASME Boiler and Pressure Vessel Code Section XI 1989 Acceptance Standards or by Fracture Analysis as provided in Westinghouse Electric Corporation WCAP 11476 Rev. 3 Handbook on Flaw Evaluation Kewaunee Unit 1 Steam Generator Upper Shell To Cone Weld, May 1991 and evaluation by Kewaunee Nuclear Power Plant during 1996 and 2001 Refueling Outages.
- 9. Recordable Indications on Loop A Existing 16", 8" and 1" Feedwater Piping ID Surface for FW-W27BC were recorded during Augmented Magnetic Particle examinations. These indications were repaired by Bechtel Corporation under Kewaunee Nuclear Power Plant Work Orders generated during Steam Generator Replacement Activities.
- 10. Recordable Indications on Loop B Existing 16", 8" and 1" Feedwater Piping ID Surface for FW-W55BC were recorded during Augmented Examinations by Magnetic Particle and Visual (VT-1) Methods. These indications were repaired by Bechtel Corporation under Kewaunee Nuclear Power Plant Work Orders generated during Steam Generator Replacement Activities.
Page 4 of 5
SUMMARY
A Preservice Inspection Program was performed at the Kewaunee Nuclear Power Plant from June 5, 2001 through June 26, 2001 (Non Refueling Outage) and September 19, 2001 through December 4, 2001 (Closing of GI following Refueling Outage). Examinations were performed as scheduled in the Replacement Steam Generator Preservice Inspection Program Plan and Kewaunee Nuclear Power Plant Third 1 0-Year Inservice Inspection (ISI) Program 1994-2004. A total of 10 Recordable Indications were detected. All Recordable Indications were corrected or accepted by ASME Boiler and Pressure Vessel Code Section XI 1989 Edition Acceptance Criteria, Repair/Replacement or Evaluation. Phillip+E.Bukes Date Engineering and Technical Support Inservice Inspection Program Owner Page 5 of 5
ATTACHMENT 10 Letter from T. Coutu (NMC) To Document Control Desk (NRC) Dated February 22, 2002 Examination Summary for Replacement Steam Generator Eddy Current
KEWAUNEE NUCLEAR POWER PLANT REPLACEMENT STEAM GENERATOR PRESERVICE INSPECTION
SUMMARY
REPORT 1.0 Introduction This report provides a summary of inspections performed and the inspection results for the preservice inspection (PSI) of the Kewaunee Nuclear Power Plant (KNPP) replacement steam generators (RSG). The KNPP RSGs were delivered to the Kewaunee site in December 2000. The PSI was performed inside the RSG storage building at the Kewaunee site in January 2001. The RSGs were in a horizontal position during the examination. Personnel from Siemens performed the data acquisition and primary data analysis and Zetec personnel performed the secondary analysis. SG2 (ASME Nameplate NB 0202) was located in the south bay of the RSG storage building and was the first steam generator examined. The PSI depicted SG2 as the "B" steam generator. SG1 (ASME Nameplate NB 0201) was located in the north bay of the RSG storage building and was the second steam generator examined. The PSI depicted SGI as the "A" steam generator SG2 (ASME Nameplate NB 0202) will be installed as the "A" steam generator and SGI (ASME Nameplate NB 0201) will be installed as the "B" steam generator. 2.0 RSG PSI Eddy Current Inspection Scope The RSG PSI eddy current examinations included the following:
- 1.
A 100% bobbin coil examination through the entire length of all tubes (3592 tubes/SG).
- 2.
Supplemental +Point rotating coil examinations of ambiguous signals, as required. 3.0 RSG PSI Inspection Results No tubes contained indications in excess of the 50% plugging limit as defined in KNPP Technical Specification 4.2.b.4. No tubes were preventatively plugged. KNPP Technical Specification 4.2.b defines a degraded tube as a tube containing an imperfection > 20% of the nominal tube wall thickness. In addition, TS 4.2.b defines an imperfection as an exception to the dimension, finish, or contour required by drawing or specification. With these definitions, the RSG PSI did not identify any degraded tubes. Some imperfections were identified during the PSI. In SGI, 27
imperfections were reported 25 tubes. In SG2, 18 imperfections were reported in 16 tubes. The locations of the reported imperfections are tabulated and discussed below. KNPP PSI Reported Indications SG1 SG2 Location BLG BMG DNG FSD MBM BMG DNG MBM HL TTS 1 Between 03H and 04H 1 Between 04H and 05H 1 Between 05H and 06H I Between 06H and 07H 1 TSP 07H 2 6 Between 07H and 07C (U-bend) 3 2 1 6 3 TSP 07C 13 1 Between 07C and 06C 1 CL TTS 1 TOTALS 2 3 18 1 3 6 10 2 Bulge (BLG) A Bulge is defined as a tube diameter that is greater than nominal. The BLG indications were initiated during RSG fabrication. In SG1, inspection revealed 2 BLG indications located in 2 tubes. Both are located at the top surface of the tubesheet (TTS), one at the hot leg TTS and one at the cold leg TTS. Subsequent inspections with the +Point rotating coil revealed no degradation at either of the BLG locations. There were no BLG indications reported in SG2. Bending Machine Geometry (BMG) Bending Machine Geometry is defined as a dent-like indication at the u-bend tangent point. In SG1, inspection revealed 3 BMG indications in 3 tubes, 2 of which were in row-9 u-bends and 1 in a row 16 u-bend. In SG2, inspection revealed 6 BMG indications in 6 tubes (two in row-5 u bends, one in a row-7 u-bend, one in a row-1I u-bend, one in a row-16 u-bend, and one in a row 22 u-bend). All of the BMG indications were present in the tube mill eddy current data. The tube bending manufacturing step is the likely source of BMG indications. Subsequent inspections with the +Point rotating coil revealed no degradation at any of the BMG locations. Dinz (DNG) A Ding is defined as a tube diameter that is less than nominal. In SGI, inspection revealed 18 DNG indications located in 16 tubes. In SG2, inspection revealed 10 DNG indications in 8 tubes. The reporting threshold for reporting DNG indications was 2 volts. The largest reported
DNG indication was 4.66 volts in SG1 and 5.71 volts in SG2. DNG indications were concentrated in the upper bundle region, primarily at the upper TSP elevations. The DNG indications were not present in the tube mill eddy current data; they were likely initiated during RSG fabrication. Subsequent inspections with the +Point rotating coil revealed no degradation at any of the DNG locations. Free-Span Differential (FSD) A Free Span Differential signal is defined as a free-span indication reported on a differential channel. In SG1, inspection revealed one FSD indication in one tube. This indication was present in the tube mill data. Subsequent inspections with the +Point rotating coil revealed no degradation at the FSD location. There were no FSD indications reported in SG2. Manufacturing Burnish Marks (MBM) A Manufacturing Burnish Mark is defined as a material discontinuity at a location which has been repaired in the tube mill by buffing. In SG1, inspection revealed 3 MBM indications in 3 tubes. In SG2, inspection revealed 2 MBM indications in 2 tubes. All of the reported MBM indications were present in the tube mill eddy current data. Subsequent inspections with the +Point rotating coil revealed no degradation at the MBM locations.
ATTACHMENT 11 Letter from T. Coutu (NMC) To Document Control Desk (NRC) Dated February 22, 2002 Examination Summary for Steam Generator 900 KIP Hydraulic Snubbers
SUMMARY
OF VISUAL EXAMINATION, FUNCTIONAL TEST, DISASSEMBLY, OVERHAUL AND INSTALLATION ACTIVITIES Wyle Laboratories was contracted by Nuclear Management Company, LLC to provide personnel and equipment to support the functional testing, disassembly and overhaul of two 900 Kip Anker-Holth Steam Generator snubbers at the Kewaunee Nuclear Power Plant. These activities were performed in accordance with Wyle's approved Quality Assurance Program. Additionally, Wyle was asked to perform Visual Examinations (VT-3) prior to removal, at hot functional and to provide technical support during removal, transportation and installation activities. Personnel required to accomplish these activities consisted of a Site Lead Technician/Machine Operator, A Mechanical Test Specialist and a Quality Assurance Specialist. Equipment supplied consisted of an API/Barker In-Place Test Machine, a 48' rebuild trailer, associated tools and fixtures. As-Found Visual Examinations (prior to removal) performed in accordance with Paragraph 6.2 of SP-55-313 Rev. D did not identify any recordable indications. The examinations were documented on SP-55-313 Rev. D Appendix A. Functional testing of the large bore hydraulic snubbers installed on Steam Generators 1A and 1 B was performed in accordance with the requirements of SP 55-313 Rev. D "Steam Generator Hydraulic Snubber Testing" and Wyle procedure 41378-1 "Procedure For In-Place Testing Of 900 Kip Anker-Holth Snubbers At Kewaunee Nuclear Power Plant". The 900 Kip Anker-Holth snubbers, S/N 25.12620.004-1 and 25.12620.004-7 were subjected to the following tests:
- 1) Breakaway Force: Measured the force required to initiate movement in the tension and compression directions.
- 2) Drag force: Measured the force required to maintain movement in the tension and compression directions.
- 3) Lockup Velocity / Activation: Measured the fluid flow (equivalent to a piston velocity) at which the snubber activated to the velocity limiting mode in the tension and compression directions.
- 4) Bleed / Release Rate @ 100 +5/-0 Kips: Measured the fluid flow (equivalent to a piston velocity) at which the snubber bled / released while in the velocity limiting mode in the tension and compression directions. This test was performed to confirm test technique at a lower force.
- 5) Bleed / Release Rate @ 500 +5/-0 Kips: Measured the fluid flow (equivalent to a piston velocity) at which the snubber bled / released while in the velocity limiting mode in the tension and compression directions.
The following is a tabulation of As-Found functional test results: Test Parameter Tension Compression Lockup velocity 1.06 IPM 0.92 IPM Bleed Rate 0.0095 IPM 0.0093 IPM Test Load @ 500 +5/-0 Kips Breakaway Force < 2.0 Kips < 2.0 Kips Drag Force < 2.0 Kips < 2.0 Kips Lockup Velocity 1.04 IPM 0.88 IPM Bleed Rate 0.1099 IPM 0.1116 IPM S/N 25.1260.004-7 installed on Steam Generator 1B Examination # 2 As-Found Test Load @ 100 +5/-0 Kips Test Parameter Tension Compression Lockup velocity 0.97 IPM 0.93 IPM Bleed Rate 0.0121 IPM 0.0114 IPM Test Load @ 500 +51-0 Kips Breakaway Force < 2.0 Kips < 2.0 Kips Drag Force < 2.0 Kips < 2.0 Kips Lockup Velocity 0.95 IPM 0.93 IPM Bleed Rate 0.1277 IPM 0.1217 IPM These test results are within the values specified in SP-55-313 Rev. D Overhaul activities consisted of disassembly, cleaning, inspection, photographing, seal replacement and assembly of S/N 25.12620.004-1 and SIN 25.12620.004-7. Performance of these activities was documented on Wyle's Hydraulic Snubber Control Cards. Upon disassembly some light corrosion was found in the snubbers. However, the corrosion was not sufficient enough to be considered anomalous. The corrosion was removed during parts cleaning. Plant Quality Control requested Hold Points for cleanliness inspection at Steps 4.5 and 4.15 "Parts acceptable for reassembly". Hold Points were placed at these steps in each control card and Quality Control was called when each step was reached during overhaul. Plant QC and Wyle QA initialed these steps in the Hydraulic Snubber Control Cards. SIN 25.1260.004-1 installed on Steam Generator 1A Examination # 1 As-Found Test Load @ 100 +51-0 Kips
Upon completion of overhaul, As-Left functional tests were performed on each snubber. During the As-Left tension release rate test, Examination #3, Steam Generator 1 B's snubber SIN 25.12620.004-7 exhibited fluid leakage around the cylinder head bolts. Testing was terminated and Notice of Anomaly (NOA) #1 and KNPP KAPWO #01-016757 were initiated. The NOA recommended disassembly and the replacement of the leaking seal. Inspection after disassembly identified that the cylinder head o-ring's backup ring had been cut during assembly. The cylinder head's o-ring and backup ring were replaced with new parts from the warehouse. Additional sheets (2 of 4 & 3 of 4) of the Hydraulic Snubber Control Card were used to document disassembly, inspection, assembly and parts used. The following is a tabulation of the As-Left functional test results: SIN 25.1260.004-1 installed on Steam Generator 1A Examination # 4 As-Left Test Load @ 100 +5/-0 Kips Test Parameter Tension Compression Lockup velocity 1.04 IPM 0.89 IPM Bleed Rate 0.0094 IPM 0.0091 IPM Test Load @ 500 +5/-0 Kips Breakaway Force -- 2.0 Kips < 2.5 Kips Drag Force -< 2.0 Kips < 2.5 Kips Lockup Velocity 1.07 IPM 0.87 IPM Bleed Rate 0.1079 IPM 0.1084 IPM SIN 25.1260.004-7 installed on Steam Generator lB Examination # 5 As-Left Test Load @ 100 +5/-0 Kips Test Parameter Tension Compression Lockup velocity 0.97 IPM 0.91 IPM Bleed Rate 0.0113 IPM 0.0105 IPM Test Load @ 500 +5/-0 Kips Breakaway Force < 2.5 Kips < 2.5 Kips Drag Force < 2.5 Kips < 2.5 Kips Lockup Velocity 0.99 IPM 0.88 IPM Bleed Rate 0.1270 IPM 0.1197 IPM These test results are within the values specified in SP-55-313 Rev. D
Additional Activities:
- 1) Fluid Sampling: A 1-liter fluid sample was taken from each snubber for analysis. The following is a tabulation of the fluid analysis:
- 2) Reservoir Fitting Replacement (Flare): Inspection of reservoir lines after installation of Steam Generator 1A's snubber identified that the reservoir line was leaking at the flare fitting (fitting to tube joint) on the control valve. A new flare fitting was obtained from the warehouse, installed in the control valve and the line reconnected. Inspection the following morning identified the fitting was still leaking at the same location. The tubing was disconnected the old flare was cut off and the tubing was flared again. The tubing was reconnected and tightened. Inspection the following morning identified that the fitting was still leaking, just slightly but leaking. The decision was made that the best way to stop the leaking joint was to replace the flared fitting with the same type fitting (Swage-Lok) used on the snubber installed on Steam Generator 1 B.
- 3) Reservoir Fitting Replacement (Swage-Lok): A Swage-Lok fitting was obtained from the warehouse, the reservoir line disconnected and the flare cut off. The flare fitting was removed from the control valve and replaced with the Swage-Lok fitting. The reservoir line was reconnected and tightened. Subsequent inspections failed to identify any further leakage.
All parts were provided by KNPP and are listed in Section 5.0 of the Final Report. All work was documented in Bechtels Steam Generator replacement document for snubber removal and installation. Steam Generator 1A 25.12620.004-1 Viscosity @ 100 deg. F 497.5 SUS SSU = (SUS x 0.0022 - 1.80/ SUS) x 100 Viscosity @ 210 deg. F 112.7 SUS Acid Number < 0.01 mg KOH/g Particle Count 5 to 10 microns 104294 /100 mL 10 to 25 microns 14550 /100 mL 25 to 50 microns 4651100 mL 50 to 100 microns 15 /100 mL > 100 microns 0 100 mL Steam Generator lB 25.12620.004-7 Viscosity @ 100 deg. F 494.0 SUS SSU = (SUS x 0.0022 - 1.80/ SUS) x 100 Viscosity @ 210 deg. F 112.3 Acid Number < 0.01 mg KOH/g Particle Count 5 to 10 microns 113994/100 mL 10 to 25 microns 21937 / 100 mL 25 to 50 microns 706 / 100 mL 50 to 100 microns 30/100 mL > 100 microns 0 / 100 mL
Additional Activities (cont.)
- 4) The reservoirs on 1A and 1 B Steam Generators were filled to approximately 50% with new fluid provided by KNPP.
- 5) Post installation VT-3 examinations were performed on Steam Generator 1A and 1 B snubbers upon completion of installation activities. These exams revealed no recordable indications.
- 6) As-Left VT-3 examinations were performed on Steam Generator 1A and 1 B snubbers at a generator temperature of 547* F. The generators had stabilized at 547* F for more than four hours prior to the exams being performed. These exams revealed no recordable indications.
Michael L. Miller Sr. Sr. Enger. Specialist Wyle Laboratories
ATTACHMENT 12 Letter from T. Coutu (NMC) To Document Control Desk (NRC) Dated February 22, 2002 Summary of Examinations Which Were Limited by Geometric, Metallurgical, or Design/Access Restrictions and Associated Data Sheets
Docket 50-305 NRC-02-015 February 22, 2002 2, Page 1 Examinations performed during the first outage, third period, third interval, were intended to examine 100% of the required surface or volume. In some cases, examinations were limited by geometric, metallurgical or design/access restrictions. In each case, the occurrence and cause of the limitation was documented. In all cases, the maximum amount of examination area/volume achievable was examined. The following is a list of examinations performed during the first outage, third period, and third interval, identifying those components where limitations occurred. 2 of this report transmits NDE data sheets for the 2001 examinations, which were limited by geometric, metallurgical, or design/access restrictions. 2001 Summary of Limitations for V Outage, 3 rd Period, 3 rd Interval Inservice Inspection 1 Method of % Recorded As Not Year Component Identification Examination Examined and Limitation 2001 Reactor Vessel Closure Head UT 23%: Lifting Lug: Head to Flange Weld RV-W12 Flange Configuration 2001 Longitudinal Weld P-W2 on UT 3%: Insulation Support Ring Pressurizer 2001 Cirumferential Weld P-W3 on UT 3%: 2 Welded Pads, Pressurizer 2 Instrumentation Lines and Curvature of Pressurizer Head 2001 Circumferential Weld P-W5 on UT 2%: 2 Welded Pads and Pressurizer 2 Instrumentation Lines 2001 Nozzle Inside Radius Section SG-UT 6.3%: Integrally Welded IR25 on Replacement Steam Attachment Generator 1A 2001 Nozzle Inside Radius Section SG-UT 6.3%: Integrally Welded IR26 on Replacement Steam Attachment Generator 1 A 2001 Nozzle Inside Radius Section SG-IR27 UT 6.3%: Integrally Welded on Replacement Steam Generator 1B Attachment 2001 Nozzle Inside Radius Section SG-IR28 UT 6.3%: Integrally Welded on Replacement Steam Generator 1B Attachment 2001 Circumferential Weld SG-W2 on UT 11.1%: 4 Welded Pads and Existing Steam Generator 1A Weld Crown 2001 Circumferential Weld SG-W9 on UT 0.113%: 4 Welded Pads Existing Steam Generator 1B 2001 Circumferential Weld SG-Wl0 on UT 7.9%: 4 Welded Pads Existing Steam Generator 1B 3-Nozzles and Weld Crown 2001 Circumferential Weld SG-W25 on UT 9%: 3 Handholes and 4", 2"/4'" Replacement Steam Generator 1 A and 2" Nozzles (7 total) 2001 Circumferential Weld SG-W31 on UT 9%: 3 Handholes and 4", 21/4" Replacement Steam Generator 1B and 2" Nozzles (7 total)
Docket 50-305 NRC-02-015 February 22, 2002 2, Page 2 2001 Summary of Limitations for 1st Outage, 3 rd Period, 3 rd Interval Inservice Inspection Method of % Recorded As Not Year Component Identification Examination Examined and Limitation 2001 Circumferential Weld AHNR-W2 on UT 43%: 2 Welded Supports and Letdown Heat Exhanger 2 - 2" Nozzles 2001 Circumferential Weld APD-1B-W4 on UT 8.6%: Welded Name Tag Charging Pump Pulsation Dampener APD-1B 2001 Circumferential Weld AFSI-W1 on UT 67.06%: Flange Seal Water Injection Filter AFSI-1A Configuration, Flange Cover Hinge Plate and Welded Name Plate 2001 Integrally Welded attachment MT 14.6%: Support Configuration APSI-1A-S3 on Safety Injection Pump APSI-lA 2001 Integrally Welded attachment MT 14.6%: Support Configuration APSI-iB-S1 on Safety Injection Pump APSI-1B 2001 Integrally Welded attachment MT 14.6%: Support Configuration APSI-1B-S4 on Safety Injection Pump APSI-IB 2001 Circumferential Weld MS-W50 on 30" UT 8%: O.D. Configuration Diameter Main Steam 2001 Longitudinal Weld MS-W90L on 32" UT 22%: 1" Elbow Taper Diameter Main Steam 2001 Longitudinal weld MS-W91L on 32" UT 63%: 1" Vent Line Diameter Main Steam 2001 Longitudinal weld MS-W91L on 32" MT 50%: 1" Vent Line Diameter Main Steam 2001 Circumferential Weld SI-W307 on 3" UT 47.5%: 3" x 3" x 3" Tee Diameter Safety Injection Configuration 2001 Circumferential Weld SI-W108 on 6" UT 50%: Valve Configuration Diameter Safety Injection 2001 Circumferential Nozzle to Safe End UT 50%: Material Configuration Butt Weld PR-Wl6DM on 6" Diameter and O.D. Taper Reactor Coolant - From Pressurizer 2001 Circumferential Weld RHR-W10 on 8" UT 63%: Valve Configuration and Diameter Residual Heat Removal 3/4" Drain Line 2001 Circumferential Weld RHR-WlO on 8" PT 1%: 3/4" Drain Line Diameter Residual Heat Removal
Docket 50-305 NRC-02-015 February 22, 2002 2, Page 3 2001 Summary of Limitations for 1 st Outage, 3 rd Period, 3 r" Interval Inservice Inspection Method of % Recorded As Not Year Component Identification Examination Examined and Limitation 2001 Circumferential Weld RHR-W48 on PT 20%: Rigid Restraint 10" Diameter Residual Heat Removal 2001 Circumferential Weld RHR-414 on 12" UT 59%: Valve Configuration and Diameter Residual Heat Removal 2 Weldolets 2001 Circumferential Weld FW-W24 on 16" UT 8%: Valve Configuration Diameter Feedwater 2001 Circumferential Weld FW-W52 on 16" UT 8%: Valve Configuration Diameter Feedwater 2001 Integrally welded attachment VT-3 100% of Saddle Weld: Pipe FDW-H170 on 16" Diameter Encapsulation Feedwater Line 2001 Replacement Steam Generator IA UT 38.1%: Nozzle Configuration Nozzle to Safe End Butt Weld RC-W76DM 2001 Replacement Steam Generator 1A UT 38.1%: Nozzle Configuration Nozzle to Safe End Butt Weld RC W77DM 2001 Replacement Steam Generator lB UT 40.25%: Nozzle Configuration Nozzle to Safe End Butt Weld RC-W78DM 2001 Replacement Steam Generator lB UT 40.25%: Nozzle Configuration Nozzle to Safe End Butt Weld RC-W79DM
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: RE ACTOR VESSEL CLOS.IME HEA D DRAWING NO.: M1 - I S*I 1 1-. I oF Z COMPONENT IDENTIFICATION: AZV-W 1 2. PROCEDURE: mEP-iS.O9 REVISION: A ULTRASONIC: LIQUID PENETRANT: MAGNETIC PARTICLE: VISUAL: ~~':ý x 6ýý )d7Z? DATE: 6/ / LEVEL EXAMINER: C /-5" DATE: 10- 2--01 LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. /k4v-w "z. S LENC-r' 139' I*i V - L, ? I. EDSCANJ 45'+ 60° EXiM-5. LlaTvrED )VE' TO LFTINJ LUC-A4T 5rVD HOLE 4.3, 0)ALL SCAMS 0' 4S" +bo' EAMS LiflirED DVE' TO H-EAD To FLAqs&C-Cmro,.&voz4r~tON. COVE&*Gi IUED*LC_ coDE/ PiocEOt'atE Covi&AC-t = Z 3 -/. OF 139* E-eAPi LEatrH, F*.or' £ Or-5LtO .Jo2L 33 TO rt OF 5rvj) HOLE I KEWAUNEE NUCLEAR A AT 1 POWER PLANT REVIEW:-- DATE: dc;DAT:, AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW:
- /9-*
DATE:__________
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: Pt ESScl'/i (tEtZ P -2:02 DRAWING NO.: M 2-O COMPONENT IDENTIFICATION: P".,v 2. PROCEDURE: kIEP-15". O9 REVISION: A ULTRASONIC:.. LIQUID PENETRANT: MAGNETIC PARTICLE: VISUAL: __ EXAMINER: -5 DATE: l*O" LEVEL EXAMINER:
- ýa
/I ~ 2Z7 DATE: 40__16 __4:_ -/ LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. P-L,,3 o REP. EXAMI IIC Sct 4.4 60 LImiITD ro A Wm,4x or-4-*' ISuLAlOt kltJ&. REDUCED CeOPEIPAOC CE P 'I.& C.D,3C-9 '&E KEWAUNEE NUCLEAR .0 A POWER PLANT REVIEW: W. DATE: COcf ,,q,00 o AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: DATE: __-Z ____
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEMORCOMPONENT: PRESV(.'?,EI R PF R DRAWINGNO.: 00 COMPONENT IDENTIFICATION: P -
- / 3 PROCEDURE: NJEP-15. O7 REVISION:
A ULTRASONIC: )< LIQUID PENETRANT: MAGNETIC PARTICLE: VISUAL: EXAMINER(7,- A' DATE: 10 01 LEVEL EXAMINER: _ __c_ DATE: It-3-ol LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. o7
- 42.
I I r 7 0 El E 9XA" AR-EA: Jl"' "r4 O" O120' (D WELDED PADS: 2.- 2.", 1" FCr-EcR TVG OF W.'LD. LlIfrED: 0' /45'(Sct.is ZS, 749) / 0'(scl.JS 2,.5,7 +8) 00 INSTvmEaJTAYTIOýI-LWJES-I' f,)APi 3.5" FP.Om ToE OF W4ELD. Liirb: -+5S"CCAM S) / 60" (sCAN S) QCLILtVArU&l OF HEAD: q" FRIO* TOE oF WEL.-*. LimjT, D : £oo" (sCM S) REDOVeED Pkoc*EbUkL-Coo/EktAC-R 3 X. KEWAUNEE NUCLEAR 10fa POWER PLANT REVIEW:/ If. _p e'. /'Iiz& DATE: Wv 6IJ4001 AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: DATE: /. /
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: PO.E SSUIU *EA P ZP. DRAWINGNO.: tl- )2-20 COMPONENT IDENTIFICATION: P-WS " PROCEDURE: PEP-15-.02 REVISION: A ULTRASONIC: X LIQUID PENETRANT: MAGNETIC PARTICLE: VISUAL: EXAMINER:-* A Z DATE: 19-3-01 LEVEL EXAMINER: 5L 4~ DATE: 10-3 -0/ LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. 0 01 U [1. Z2.142*4 EXA, M A P.A.: If& r I" A- .0" (DOO '.LDEi PADS : 2." 1" F.LOIM EAC_.) TOE OF WELD, LimroD 1 0" / 45" (.SCAMs Z,S, 7 + 9 ) / co (scAMS z, F, Q@( 45rizvmTi5-TA'r'I0 LIE-j5: l"DAM)-, 3.5" FAo-1 -roE 01 C-CELO. Lim,,TED: 45" (sCA,, 2.) / Co" (-sCAN z) RED/cED PO.*EDvciiF CoVVEAGE 27 KEWAUNEE NUCLEAR A -J-1 POWER PLANT REVIEW: -x. ý DATE: D'4 6.*'i AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: DATE: /1-f-01
WISCONSIN PUBLIC SERVICE CORPORATION REV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: P.EPLAq 4c 0 5Tfl Am
- G5e,
,l&gATiIo*s .S-A IiAIM s - 6 a DRAWING NO.: fYA-1201 COMPONENT IDENTIFICATION: SCG -.It* as PROCEDURE: A1EP-Y.QLL REVISION: / ULTRASONIC: X LIQUID PENETRANT: MAGNETIC PARTICLE: EXAMINER: IOrJA DATE: t EXAMINER: "TlAu15 THo,'OMAS LEVEL VISUAL: a "01 DATE: t22--OI LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. 4l.o" Orf lAi-iGRALL4 LI/MITE1 (610 SCAAJS Ar NOTCH F UkLOCO ATTRA_/I)EAJ-r SG-IA-a*ý3 3 WITH .ALIt!MIITIOAJ
- FOI, AOTII 8
tLAcault~ 0 E X~ritv £ VOLIA,4 MoT ('.3 1. KEWAUNEE NUCLEAR POWER PLANT REVIEW :/ 22C DATE: 00 1QQ AUTHORIZED NUCLEAR Z9 INSERVICE INSPECTOR REVIEW: / DATE: 6 (
WISCONSIN PUBLIC SERVICE CORPORATION REV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: REPLAiCMcfif ST Am GEoMJ1"Tbot5 SG-/I A AuO.S& -I 13 DRAWING NO.: m-laJ COMPONENT IDENTIFICATION: SG-TZ 2(, PROCEDURE: A6P-/1-.Y REVISION: J9 ULTRASONIC: X LIQUID PENETRANT: MAGNETIC PARTICLE: VISUAL: EXAMINER: JF/ toMiAJ) Or DATE: /--2?co LEVEL EXAMINER: T*ituis TigomAS -E DATE: /a0-4O -0r LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. iq.o" or IAIjTre,9ALLl 1XL00 lAV 1rAC HMAfr/ SG-J IA-23 S L IIT/o laDo SA~VS wIry T _ALI639ATWoA Fos NO TC H 15 Af A3 AJOTC H f KEWAUNEE NUCLEAR POWER PLANT REVIEW: AUTHORIZED NUCLEAR VA 1IN'SERVICE INSPECTOR REVIEW.:~ '"~ DATE: L,-15,300 DATE.___-_____ uAEQtAlACn VOLL1Ac AJo1r WmtmIA)U 6o.31.
WISCONSIN PUBLIC SERVICE CORPORATION REV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: REPLACCn'i-MT STA*A(h GEAJEaATOrt5 SG-I nl AMt SG-I 6 DRAWING NO.: 01-iaoi COMPONENT IDENTIFICATION: SG-lt 9J-7 PROCEDURE: AIEP-15.q'I REVISION: A ULTRASONIC: X LIQUID PENETRANT: MAGNETIC PARTICLE:__ VISUAL: EXAMINER: zr/'t !t oAJ .r DATE: to-I3-O1 LEVEL EXAMINER: -iaUfS THOMAS _u DATE: Lo-33-OI LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. IH.o" or XAJT__G9ALLi WSLOLE ATTACH/YIET SG 23 0 LImiTTeL 0DO SiCAR(J! LITH 0_ALI6fATIo/U FO(i AOTC1I 6 AAmft F. (REWAIMO UJOLLIE AJoT z s I f KEWAUNEE NUCLEAR /3/] /A/) POWER PLANT REVIEW: ,*'j* DATE:," 15.3,01 AUTHORIZED NUCLEAR DATE: INSERVICE INSPECTOR REVIEW: / DATE:
WISCONSIN PUBLIC SERVICE CORPORATION REV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: REPLACFnetur ST6AM GEtunToATDtS 3ri-IA AiQ SG-i B DRAWING NO.: M*- IaOl COMPONENT IDENTIFICATION: _SG-Tk. a PROCEDURE: A)EP--IS.' REVISION: A ULTRASONIC: LIQUID PENETRANT: MAGNETIC PARTICLE: VISUAL: P1 C)HA1.0tJ EXAMINER: LEVEL EXAMINER: TRAu15 THOMAS LEVEL DATE: 4-93-0I DATE: to-, I SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. 14.D" OF r)THg*kaLLq 1/JELOE0 F OTrAC8H41A)VT SGI T-23 6 LIMITF tobo' SC~AMS LLJiTl 2AL16kATJoAJ F6'LAJXrCH 8 $AAW rtJOTCH F REQL&IlEa bAMI)IMEf zzC U VOLV4I* AJOT (.3 7. KEWAUNEE NUCLEAR POWER PLANT REVIEW: e'. /& w DATE: tw'5lOoI AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: DATE:. - *-/
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID. PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD Fxis$r/A1&.jc, RrN &Ae-FPLLmr-1v SYSTEM OR COMPONENT: STEAM CE.1ERATORS St.- IA AND - I B DRAWING NO.: M-1! 20& COMPONENT IDENTIFICATION: !3G-W2 PROCEDURE: NEP-i6.09 REVISION: A, ULTRASONIC: X LIQUID PENETRANT: MAGNETIC PARTICLE: VISUAL: EXAMINER: ,.r LEVEL EXAMINER: LEVE DATE: 111IL16i0 A //: i ,o/ DATE: 11116161 SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. 0 REF. !5 SIDE LoUR WELDED PADs 7.75" X Ib.'15 " M,-At.UFD INTWF CW DtRee Ttc4 F!om OREV. LewA7mD ODA1rI. WELD TOE. 61JT TE 5 SiVE OFr T"ig-WELD Ltm TS 6,,1AJN2 SC..4MS. WELD CROWN LtITS SCANS 0.,,Lq ANDS Vbg THFE 1450 PEOucfD Co'9PF/RocODuRIF 6ovEP.A66 'r3 7% KEWAUNEE NUCLEAR /D POWER PLANT REVIEW: DATE: A/,17,aOOJ AUTHORIZED NUCLEAR ,272 INSERVICE INSPECTOR REVIEW: DATE: // / 3.
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: 5TEFAm (regs'alnIS EYqT- ,1IN&hLb 9EPLALCE*MOIT S6-I1 A*.si S&-i#, DRAWING NO: m - (_ COMPONENT IDENTIFICATION: - c-C2 PROCEDURE: NEP - IS. 0 9 REVISION: ULTRASONIC: Y LIQUID PENETRANT: MAGNETIC PARTICLE: VISUAL: EXAMINER: Tm'A COA 16 -LE DATE: 7K LEVEL EXAMINER: 1vJDATE: \\ i(o~ LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. 0 REF. 5 SIDF 5 SIDE 1 u.R WELDED PADS 7-75' X Ib. 75" M,-A£RLRED IfNTP.F (-W DtRMELT*TJ I0M DREV. LaCAwtD ONTAE TWSELD TOE ON T14 5 SE
- .Tq5-"
WELD KEWAUNEE NUCLEAR 4~j POWER PLANT REVIEW: DATE: Vife7i AUTHORIZED NUCLEAR 9 INSERVICE INSPECTOR REVIEW: 14 DATE: //-o-*/
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: 5TE~AP &6-E kATRS EXlsrul6-A *b (2PLj9r.CflElT $5&-l1? AAL <6-- I1 DRAWING NO: 14-12o0t COMPONENT IDENTIFICATION: 5 - W£ 2 PROCEDURE:Pý-l*2.0 REVISION: ULTRASONIC: X LIQUID PENETRANT: MAGNETIC PARTICLE: VISUAL: EXAMINER: -Tim Cc),oBL.,,, /A1-41,//-- - 7/" {/k LEVEL LEVEL DATE: I I/Ic /01 DATE: w///o// SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. 0 REF. 5 SIDE / /1 I/I 5w '////////2/i/,// 'ill71 71111'/I 7 Sq- ; /Z'///// ID// SOLUR WELDED PADS 7.75'X 1D.75" MEAS-LRED OREV. LoCAmD DAIJT$15. WJELD TOE 6J T-]4E9 5 SIDE O T'i WVELD LiTS 6,', AiTD2 SJCA4S. 3. WELD cRowm LvrMrS SCAN~S I)5/(ANiD 9 VD TH15 GvO $etF.bcFzt cbc-c / Pf-C-EUP9E Cc0FPA&GE 8Y 0.57. F69 <,-ý -7 A~Ub 9 LUE TO L3E:Lb-- ~PAbS.
- 14.
Eibc. / C /otE I PRbcg)kE coop-m&E. 2Y O,5 7X "P.. ACA,'L S, g~dcE Cobc P96czbf)E cc,0EkA6-c-BY oIF 1M 2. KEWAUNEE NUCLEAR POWER PLANT REVIEW: __._DATE: AkY 1-J001 AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: DATE: //-,010 EXAMINER: n r II [ E..
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD ExITt~srtcs-At~b AzPLALEMENT SYSTEM OR COMPONENT: STEAM 6.tEv*T0..( !5&-(A AD 56-- t DRAWING NO.: Mi - A12 COMPONENT IDENTIFICATION: !5 6-Lk9 PROCEDURE: 1z'P-15*cl REVISION: A ULTRASONIC:.2 LIQUID PENETRANT: MAGNETIC PARTICLE: VISUAL: EXAMINER:.11 "T( C_5*-V I-iQ DATE: __6_ LEVEL EXAMIN ER:(Z>1vi'ý I[ DATE: C-01 / I LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. 5e*V. '2* 5%tE iAT CEM*9TER OP F~eJbLATER No2. LE Lbb~P-At 2.--1~
- 2.
1-cA (00'0 i'~.om 0 APEAENC& ON 5Sle Z. t3E.bEb PAO 2.11"X 2.-l L-OC-AT~2 5o06 F A# C ErENCL CýA 5 LOE q4. EL~~bEb P/lb2.>'"x 2.1" LDC-ATEb 39D iELomO C) 9C.EAEE 6ti:5 SOe). ALL PbL*S L.L" FFPoD4 TOE: nF LtJ*L-tb n. S SbIbE. 'ýAt4 5 LLHINVEti OPI' THE: t450 Atb Loc 0 b~ur--(E~LOLbEbt PINb$. KEWAUNEE NUCLEAR POWER PLANT REVIEW:/
- 7.
/10-4e13 DATE: Cc 1ajdoI AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: DATE: /.-/*-/
WISCONSIN PUBLIC SERVICE CORPORATION I KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: STICAm 6e,,Je(A oR& 9 A;O esr 14,ht ..6-1h'l A A 0S6-1 DRAWING NO.: M - iz_ o 6 COMPONENT IDENTIFICATION: SG-&J io PROCEDURE: 1,10P" I.S',- REVISION: A ULTRASONIC: LIQUID PENETRANT:__ MAGNETIC PARTICLE: VISUAL: EXAMINER: DATE: /1_'17/62 1!1 LEVEL EXAMINER: ci DATE: 1/112-1 0, LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE.. 0 9r z. Laf-.ATE~D AT Cet.~r"~ 0$. F~lESOW'dA
- ~ ~
~ ~ ~~2 S 1 ,) F*,-',O*EEEJEo OF~ LiM%,r 00, +S' + 40 ScA,5 V
- 2.
L 2.S t"XtoI. LO-.&i) rA9-pareq.II ý ~4 Rom" -Joe or 3.- WVLDF-1 ?A0 4211,4A I 10BJ4 L04Ar9. b A-r 14' 00z"c.,.for .EJ~ei~ WE LDWAUNEE LiNrUrs GO'
- Z POWER~ PLANTREVEW:
V .1j (jZ
- O~
DAE0 V*.** S2" ý10?TLF-LoGA-riro A-r 2.4' 11" c -o. FP..bo 2g Er-E'~' ag 3 jFjcF76 W r:L0 . Sr S 1 L 4 t-YrS ,4e ScAr w F L0 F1 10Ax f 3 /*'1+"x 1~'o-70 "/+ "39 0AIf .6 ,~ 0.. SSJJ06 00 v ,6L,/vLI rS 0'0 06o +- 4o0" Sc-AA.JS*
- g.
5ULD Ciox LimI or', Oo GOO0 -c,.4J c~ F~APC m PAD Z-' PLAR.4T-A Tv F-. oF: iwA-Jb vl-LM- /JOT KEWAUNEE NUCLEAR POWER PLANT REVIEW: 2 DATE: Ngrd1ý.o2'col AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: DATE: n M I e,-%I
WISCONSIN PUBLIC SERVICE CORPORATION REV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: ST£KmA GlE().ATO& J41,0T,G AFJ 8 PLAClEPLAC rT SG-I A f SG-I 6 DRAWING NO.: COMPONENT IDENTIFICATION:.SG-Lk a s PROCEDURE: AIEP-1.S.D0 REVISION: A ULTRASONIC: X LIQUID PENETRANT:_ MAGNETIC PARTICLE: VISUAL: EXAMINER: EXAMINER: TRAu15 714omAS Tn LEVEL llýM~cý s ýfIAY)ýcoAi DATE: L m T3 DATE: to - *-0 I LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. RRAU a s%~~. " mm~V TOE OF IELý .5 S-£J. a 'i" !JO07_..LL 35"-S". *. S FU.M TOC OV MiELD ',I S\\SF. 3 IAAMNOIJ II"-i&D, a-0" FktM TOE O W-C-L 5 SqjE. L c" jnOL.LC 1"-11"-\\61", 9 TOE_ OV WJC.U 5 SUýE. s a" AJOLLC-2LI"'- alb" P_ TDE LM WELtb 5 SltE.. ' 6 4" AJOU.LE. L1Y -_;55*".5" Fý Ocn TOD f3N WL a Site -1 HRJM1OLE 2417)." -aGl a.S" FMf TOE 0 F WN3 ML S.SME_. S. a" OUOULE aS-5A"%9"', TOE NI WAEL 5 S\\5. q0. el"'AJOZZ.LE IAU&'*5-l TO OV..* W0LEU 5G.'SIM.' ID.LI3 a Sd x5E. 0o SCA: L\\AIMs.AM \\ FLOrA ITEM S 4
- t*
5 %L'A"1 9 o REOmi(Ea VOIoAAC t\\JOT LXAiMu'EA = SCAM 2 : a5° So" i" "I S LUm\\'*TAoU -cl a~on**I SCAN I': i I'," 4 so i °(z, LiIPITATioý R*OM It5EM S S1,5, % 9 I0. IC (e.5" 5 KEWAUNEE NUCLEAR POWER PLANT REVIEW: 76e2 DATE: 12,,2. 00)O I AUTHORIZED NUCLEAR \\A INSERVICE INSPECTOR REVIEW: DATE: e F'h-I a0L0 I f
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT:*S-r.4m GeVetrdTo,9 Eu7"t ,Liee.,e",rsi"4 Y,56 cr-18 DRAWING NO.: /A-IAO* COMPONENT IDENTIFICATION:.S&r - tWd3l PROCEDURE: VJEP'/156? REVISION:- A ULTRASONIC:_Y LIQUID PENETRANT:__ MAGNETIC PARTICLE: __ VISUAL: EXAMINER: h EXAMINER: 7&*- 7-/,5/)ma4 LEVEL DATE: 6,/*/-2/ DATE: e.,,.,/-4D/ LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. 5 I RRHdOLE as-S a.51 ýlcom TOE 0F 1WELý .5 sltE. a "A" 1U 07ILL 32S-M". LAI.IISI FkO(vn T()ý Dý *JLD 'a Sine. TOE OF W-CLl 5 Sl1iE. S J0L7..L_ l13"-\\$", A TOE W CL 5 S 5E£. q a " AJODL 7-L C-IN-21b" R_ TDC Oý WELE 5 S\\lE.. Ca '1 AJOLZ.LE. aLj~kll_;5J: a.S" l unL TOE OF iWELa a sinE "1 AWR4OLE M.'h"- a.I' FMM>Y TOE. OF GUdEý 5 SIt. a" NOUL.LE.l 5"- '9"2 TOE 13ý WJL3 .5 S\\5.
- q. al" tLZZ.LE IAU- ~as a
TO70
- 10.
- YhWAJ0ZZLC
~c Q3.5" ý-kof\\ ToDC OF D 0L SCA: L\\MT\\VJ FLOM\\ ITEMS SCRM~ 'S'. LQY (ar LVAIWU ýgftC =T~u.EMS
- DLYt AJD.T S 1,S cAiV.A~
SCPA3 ;I : Lkso~ i (n34 I L\\VA\\'TAf Uo U ýL16' \\ T.. S.,CMI: 5, S, t o. L ITRTtfjý FUM I T\\ IM5 t 1 i%9 ii lO6.5" I.,e-5 KEWAUNEE NUCLEAR POWER PLANT REVIEW:
- 6.
DATE: II, 1 I AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: DATE: /¢. "( tý-
WISCONSIN PUBLIC SERVICE CORPORATION [REV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEMORCOMPONENT: LFTbOwdi HEAT E. YCHANC.ER ARiLb DRAWING NO.: A,-1I209 COMPONENT IDENTIFICATION: AH4NR - , 2 PROCEDURE: 14_P-15.41 REVISION: A ULTRASONIC: X LIQUID PENETRANT: MAGNETIC PARTICLE: VISUAL: EXAMINER: TiN-{ C.6t) N //f LEVEL EXAMINEF t, A ,AA DATE: io/zq /01 DATE: IVA LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. RESTRICTE-b SCAN 2,5,1,8 buFJ Th WELb.b "1' CUTLE.T LIM I TS WiELb AHAJ - W1Z r-t ROtv 42"-
- 44.
0
- 4.
'q U PPOR 7"5. 45"- RESTRICTEb -SCANI S buE TO INLET A*JI OuTLET 2! LldES. REbUCEL CobE COVERAGE 91 45"/. KEWAUNEE NUCLEAR POWER PLANT REVIEW: /A -i%2' DATE:__________ AUTHORIZED NUCLEAR DAE 19.1.0 / 1 INSERVICE INSPECTOR REVIEW._: DATE: /&/'9 45-
- 1-
WISCONSIN PUBLIC SERVICE CORPORATION lREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC.PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT:'.iA*,* iP P.MP"lArloWDMPEA*M-* A - IAt, Af-.l ApJt, APb-I c DRAWING NO.: /v-:L o COMPONENT IDENTIFICATION: APO - ia - w,4 PROCEDURE: NlEP-16".ql REVISION: A* ULTRASONIC: LIQUID PENETRANT: M EXAMINER: 4WA% W EXAMINER: _ELt C060.e 14 AGNETIC PARTICLE:_ VISUAL: LEVEL / / /1-11" LEVEL DATE: to-/&-oI DATE: SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. 0 REFERF-prJf- 'oi NAMS TAG'
- 1. INAmETA6 LIM ITS '46' 54Ai 7g SOM"E FOP, S>,"
tJAMErAG I SLaeCArtb q * -o 9YL rto lmMAAIl4.D 0 AhJD>1"FO f~A N-T51Df N 1 &s00T CHAAAIAuG PUMP PUL.6A-rIO&V tAMpPuvgp4 18 )ZEbLICED) CODbE cO6EAAG6 Y KEWAUNEE NUCLEAR
- i.
POWER PLANT REVIEW: D 7 JATE: 6",& 2._,_ o AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: DATE: A
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: SEAL WATER loaTEc-TIoM rII-TeRu A FSri-IA AID A FST-IB DRAWING NO.: M-J.I.12 COMPONENT IDENTIFICATION: AFS-11 PROCEDURE: AIEP-1d5,1 REVISION: A ULTRASONIC: k_ LIQUID PENETRANT: MAGNETIC PARTICLE: VISUAL: EXAMINER: EXAMINER: AlA NA LEVEL DATE: 101-14/01 DATE: NA SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. F~,4.-CovE-s 'Atvc PLRTEF FLACE -
- (N*l6.L*
l.*r*B* Psz i--?l W DC9-1; It'. 07LtE 0 RF.F. - AýS--w I-
- ANjcE.F Co&3:LaArldA3 t..imtTS 5,14e SC-AN4 FoR 454' RL. WE-LD r-RoIAi LiMi'T 245,17"g' SCANJS FDP. qS'IRL. FLN&
oc 4 Q~a.E PLArE.. L6c.,TEb FROm 1.6'".*W -66 Iq.6"CW3 FRoM 0 REPEmic-LtmiTS ,* 7+-- SCANS F7R &S°0 RL NAME PLT*T. L!,&-TEbD IRom 2'.o" C.WTo 19.0","tl Fr6M i REFEREAJ... o.q* "R6M T4E ar-WELD AFST-wl LIVr- .2 Se-A F&4P_ 4AIRL. 670676% PgodFDmIE CaER~F-A6L r5 nS-miuJcD. KEWAUNEE NUCLEAR POWER PLANT REVIEW:
- 61.
DATE: 7V -}I 10 AUTHORIZED NUCLEAR IhNSERVICE INSPECTOR REVIEW: DATE:_________
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: SAFErY ri-56TlouJ PUMPS APsPSI-IA AA )OiPSir-I A DRAWING NO.: M-1101 APse:- I At-53 COMPONENT IDENTIFICATION: APSZ S PROCEDURE: ME? iOb. 15.1 REVISION: ZKIG' ULTRASONIC: LIQUID PENETRANT: EXAMINER: Awm 44.- EXAMINER: LEVEL MAGNETIC PARTICLE: K VISUAL: DATE: IO -a 7-01 DATE: IU A: SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. T'P. oF I 56,Af'OLrS EOMIA)66 i, AREA MXOT LXAMnw*Et = SAErCV M.CiOA fAM? e LASA)& LtMITCi1 AL£EA AU -r ANO ALc*iES I H.c I. / KEWAUNEE NUCLEAR POWER PLANT REVIEW: AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: V 4 DATE: ________00_ DATE: 7A4__l; LEVEL m l &,a e /lAw
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: ~MAtM STEAVW STEAM- &GtePE(A70e~ IR, DRAWING NO.:
- ,-A e -2 COMPONENT IDENTIFICATION:
f-{S - Li So PROCEDURE: NE P -15. .oREVISION: iq ULTRASONIC: X LIQUID PENETRANT: MAGNETIC PARTICLE: _ VISUAL: EXAMINER: "T'If .08 ,NI EXAMINER: A. /1 f// I wlr_ DATE: Lo /tz I/cq LEVEL DATE: IO/0 1 LEVrEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. Q S No SCAi S s 1-1 0i. (qE5 b LE-6 0E TD n C-0K t& L)P-T L.O'4 p'Etc~Et CýDE C00:FAG*-c7 oby KEWAUNEE NUCLEAR 7* POWER PLANT REVIEW: ,,,/ Id DATE: at2/"./-____1 AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: DATE:
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID-PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: MAtN 5TgN 5TEFLM £r-EN.6RATR I DRAWING NO.: TrS=- M 72 MS I-LtP9L COMPONENT IDENTIFICATION: M $ u) 'IL PROCEDURE: NEP -15.40 REVISION: 14 ULTRASONIC: 'X LIQUID PENETRANT: MAGNETIC PARTICLE: EXAMINER: "ltt C03UI.. f// EXAMINER: "k41
- 7 LEVEL SKETCH TO PROVIDE:
VISUAL: DATE: 0//_/__/_1 LEVEL DATE: 101,;116 APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. 1450 - LimirEL zis,1 SCAN' OM WJEL6 4Mb-LJOL LU To 1" EL&O rAPER. SCRM,5 2,5," 1 LLMITEL' i( 3" ,N c'L JLb MS-LqlL boE To I" aCNT LINE. .L E lMS-W 'inJ9L Q CLE C_. C_-OU/,Ab-6" P'V 2Z°/,6. JEL., MS - Wql L EbOC._E C_.bP" C.6,e5RA&- NY.3 11/o, KEWAUNEE NUCLEAR POWER PLANT REVIEW: '. U DATE: O 8o i,0I a AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: DATE: //
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: AAA W4 SrEAM STEAM GO-ERAThR 18 DRAWING NO.: -_STA - 97,2 COMPONENT IDENTIFICATION: MR - W9lL PROCEDURE: At[.Pgo. 15. 1REVISION: QRl'e ULTRASONIC: -__ LIQUID PENETRANT: EXMNR EXAMINER C ý MAGNETIC PARTICLE: X VISUAL: LEVEL LEVEL DATE: eO/iilc'i DATE: iO/1Io SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. " u, LiMir-b V M i: 1'+D ti" .. WI% R2D0.PF..E C.OVERA0E. m*s -W5o KEWAUNEE NUCLEAR A POWER PLANT REVIEW: C. X DATE: ____ ______ AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: "_DATE:.___________
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT:-SI - FRomcr-rrT PPJ. 2;SF. TO.'" 8RAAAC CoNm or, (&" HOp TO RFAcrOI DRAWING NO.: IlSiM-q37 -A*H3, I COMPONENT IDENTIFICATION: 5l-w30) PROCEDURE: NIp"P-15.41 REVISION: A ULTRASONIC: X LIQUID PENETRANT: MAGNETIC PARTICLE: VISUAL: EXAMINER: ruAL( C-jte.4 9w0/1 LEVEL EXAMINER: _z_ DATE: c D (t,6 (0 DATE: /-/0oJ LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. I...*zj rE.r m5'5°- CoSCAf 2D4JTor5.,.ONFIGukVPt"oN RabuECf CODE CovERA -E,,7.5"/. KEWAUNEE NUCLEAR ,7.i POWER PLANT REVIEW: / C7DATE: Oct& ý_z__ I AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: DATE: I /" / Ir
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: 51- *o' w-r PEN. to TO PUAC*VR, FROM AC.,r'R 18 r-o LOOPS 46.b LEG DRAWING NO.: 151 M"1:19 -ZS541 COMPONENT IDENTIFICATION: 15--JIOS PROCEDURE: NEP '"1S.. REVISION: Af ULTRASONIC: ) LIQUID PENETRANT: MAGNETIC PARTICLE: VISUAL: EXAMINER: EXAMINER: - LEVEL L2L LEVEL DATE: 10-3O- 0 1 DATE: /-0O( SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. S1-w. o8 " plOaw No SCANS S. 7,5 ON 5 SIDE bvul-O VAL-VE 51-3o1A CoNFiGuRATjoAJ CODE C.oVEPAE fgEDuc-o6 8', SID;' KEWAUNEE NUCLEAR POWER PLANT REVIEW: AUTHORIZED NUCLEAR "INSERVICE INSPECTOR REVIEW: DATE: DATE:._________ /1 ¥
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: P. PcTTO( CwOL.-AT - FAtZ PýE5$&L)JZEk TO pf SLEP2,(, t0L_(EFTANK DRAWING NO.: _zs5_7-9q0-2 COMPONENT IDENTIFICATION: 0P, - W*g LOf PROCEDURE: NEP-15,t Lj REVISION: o ULTRASONIC: -, LIQUID PENETRANT: MAGNETIC PARTICLE: VISUAL: EXAMINER: 7"Tm, h ogN -2r-fjjZ' LEVEL EXAMINER: LEVEL DATE: I)/7* ) DATE: /0-25`01 SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. z 8 / C_ : 1'1aaFAvfe -E c;= CoE I P~c*jet) Uskrw cj-. ____/ ALTUA.L PAeT Th-IArvN C-5s: 1. 2" CA.L. I'- CY WbP.. '1 k I
- CkMý.e 5 : 0.1 ( 9' L.
[2 LL kq IL.1 t tujSlbNS. (DO'= L~. '2.*LL AT B. I~ _1A,< Lc too' - No SCAM S ýI3E Tb I*TE.(IL 0..-tEF(L9-~f-l&N. .CANN 2-LIM-[T I T,3T C fD)T-A PE12Z. JCAtM -1,G L. IMTEL TnN S GIbC t-r-TO MAt-',*lIL COTQ P(&r0KAfTtoN. KEWAUNEE NUCLEAR POWER PLANT REVIEW: AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: ft4o <./JAJ DATE: 0)6
- p 1%0O1 DATE
/&//Z?d/, LP
SYSTEM OR COMPONENT: R 9 R. P., R(C Lps A*4* Io* Ls +f. CITMT NO., +- CqTMT _M.T R .-j DRAWING NO.: ISt M - 51S7-1 SII COMPONENT IDENTIFICATION:
- RR-tO PROCEDURE: NE?-- 15ql REVISION: A ULTRASONIC:
LIQUID PENETRANT: MAGNETIC PARTICLE: VISUAL: DATE: /0 -f-I DATE: LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. LooKJjus FAS' vALV-A 2sWa' -t-p t64t 0ý q.-eJA RRR-W to I tib c.*wS ,1-g - Vda~Jc SiAe clJje Sc. 2-hll.1+eA -Auc +' c lro~ ti Sccv Sfl \\Jo.lucslL ~iclo
- 4. *a6vvp3.f.irai~ ta s-,
z Z,> t.,4e c&.)t wm % ReAucec\\ Cce.( o.1ce. 37. KEWAUNEE NUCLEAR -."0/ POWER PLANT REVIEW: L4. f DATE: ab( bd 001 AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: DATE:- ( WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD I
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: il -k.:om AC LOOPS A ! 8 oTl.96ST'ro t,¶rT PPeN. k? -O ror'sJmp is DRAWING NO.: -5i-1i - 1:21S1 COMPONENT IDENTIFICATION: AHJi -i,0 PROCEDURE: NfPPJO.-.(e REVISION: O JG ULTRASONIC: LIQUID PENETRANT: X MAGNETIC PARTICLE: VISUAL: EXAMINER:_______ EXAMINER: LEVEL MA LEVEL DATE: 10-io-O' DATE: SKETCH TO PROVIDE: LaoOKiJ EAS APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. I - 0 AAI-N LI NE L/4ATE 6ý, 'r'OTM FAoM TOe O6.i'EL4 JAitW.it JREuCeb c.0OF-cAE,0E I1;. vALVe. K.HA-IA floW LOOKING UP KEWAUNEE NUCLEAR /1-) POWER PLANT REVIEW: e DATE: 0 0C=1 r AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: DATE:___________
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD RHlR - FRof4 JZC LOOPS A,4 8 HOT LG TrO SYSTEM OR COMPONENT: C,7T-,T PEIA c 91 ro7 T A/TA,,T SUm-P A DRAWING NO.: _TSIA4 - 9 1 - /SH COMPONENT IDENTIFICATION: RhR4 - w4a PROCEDURE:A/P' 1'o./5(o REVISION: ORIG ULTRASONIC: LIQUID PENETRANT: MAGNETIC PARTICLE: _ VISUAL: 12Ac7-&4,4 5AI Th 6' LEVEL LEVEL DATE: g?-zq-pl1 DATE: HA SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. NO E.YAM FP.oM 1.5 ccw ro I.S"CW AAI, 14.<"ro 18&5" FROm 7"b bu 7o BOY RESThRAI,,IT INT..RFEREVCE REMbUL El(AM CovgRA&E IS 20/, S4" CIAC UM FECENCE 7" REbu CEb KEWAUNEE NUCLEAR 'j, POWER PLANT REVIEW: /DATE: 064& 1, zo 0t AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: DATE: /-/-/ EXAMINER: EXAMINER: Co VF-RA4*.E
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORI KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD R9iR-FROM wdT'T r J4PS Ad/b AAgCHOR5 "rLtRU AHR PmIP IA1 SYSTEM OR COMPONENT: TO ANCI.OR o0,4 0I1SC4. LI,/. DRAWING NO.: S1M-c968-ISH4 COMPONENT IDENTIFICATION:.RHR-w414 PROCEDURE: PEP-1.gI REVISION: A ULTRASONIC: X LIQUID PENETRANT: MAGNETIC PARTICLE: VISUAL: EXAMINER: LEVEL EXAMINER: t'A ,iA DATE: 10.24-0l DATE: NA LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. RliR-V4414 S51--65 1A FLOW No SCANS 27 1 ANh 8 ON ISlbE buE TO VALVE CONFIC.uRATION, 45* A?'* 70* SC.rAN 5 LIMITEb FOR 2." Af TbC ANO FOR, 2'"A1 AT1C bUETo WELbO'LK7T. WELL 0' LETs LOCATEb "/4" FROM TtE. OF wtFL-AT T.LC, AA1 3/4" FRoM ?be. OV WELD ArT t.D.C. CODE CoVERACzE &FbUCE-b 6y 59/. KEWAUNEE NUCLEAR : /___ ea_ POWER PLANT REVIEW: e__13 DATE:____________ AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: DATE.__ _-_____DE
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: FEEtrEg-p* F.n-t rqNcNH.o.-b f-L TCý 5TE,qNLA' &4., I1 DRAWINGNO.: .S.T-t-91lO COMPONENT IDENTIFICATION: FLJ - LJ Zq PROCEDURE: NE,.-I 5, LLo REVISION:A ULTRASONIC: X LIQUID PENETRANT:__ MAGNETIC PARTICLE: LEVEL NA LEA LEVEL VISUAL: __ DATE: tD/2:01 DATE: A/A SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. I 0 5 5*bG L450 S-A* 4 S i E5TA(C-LTE~b OOE TO L tuLJU CoAJFI &f1(LR"iTLnN =Oo- !!S P-S S-T*i.CTLhb b)E TO UAL.Pe COkF*LR TLOK'J.. KEWAUNEE NUCLEAR POWER PLANT REVIEW:7C DATE: AUTHORIZED NUCLEAR DE P, 0 INSERVICE INSPECTOR REVIEW: DATE; /'t-/ EXAMINER: EXAMINER: tot C08')fAf le 011 FWJ - I-J 2___ - t3A
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: Fie bwTE_ Fgoyt ThNC-24*E&' t.L. TO STfA &EA-*., DRAWING NO.:
- '_Zt#4 -"7?
COMPONENT IDENTIFICATION: F, - tJ S 2-PROCEDURE: t4eP-tS. HtZREVISION: ULTRASONIC: X LIQUID PENETRANT: MAGNETIC PARTICLE: VISUAL: -f7 "LEVEL AA IVA LEVEL DATE: fD/bD/ V/ DATE: A/,. SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. 5 5LDE L6, _ 5cI4 5V-1, 9 X.*sT4-c-Tt'r6 DOE TO Vt3LUE .6o ý,- t5c-A SL s pE-F1LTt_(-EJ WŽE Tc ULXt~E-CoM cz) m Ft b-Iop--q TL*c cm =: L5Of24ATlotL. KEWAUNEE NUCLEAR POWER PLANT REVIEW: DATE: __CU____7_____ LI AUTHORIZED NUCLEAR DATE: INSERVICE INSPECTOR REVIEW: 0AE______ RVA W ftAr 'mD f, I ') t? EXAMINER: Fw - tis'z--- fZE:bL)Cpb Cc>bC
WISCONSIN PUBLIC SERVICE CORPORATION REV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: R.-D'WATER rROM Ae.__a-FD ELL.) ST4FAt (.. /8 DRAWING NO.: -_TSM-q11 COMPONENT IDENTIFICATION: FlDW-H 1 'i0 PROCEDURE: AIEP&.k56REVISION: 6b4!5 ULTRASONIC:__ LIQUID PENETRANT: MAGNETIC PARTICLE: VISUAL: X; EXAMINER: ~s~4.'
- ?
EXAMINER:
- rr LEVEL AMA
,A/A DATE: /e: / DATE: LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. VT~-3 EXA~M LimiTAT'101. I tLu.eTo ENC.APSLLLATION PtPf. kAotLMh THE ~'THE SADOL6 WELiD CA14AOTr BC Sr=F4 U KEWAUNEE NUCLEAR POWER PLANT REVIEW: .1 I,008 2 7DTI**,00L.aDATE:QC /*.,L00Ž AUTHORIZED NUCLEAR I;NSERVICE INSPECTOR REVIEW: DATE: /.- '/
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: R.ekcmok _L.rr L..oj, "A" DRAWING NO.: tStM- 'To7 COMPONENT IDENTIFICATION: ,3-, bt,, PROCEDURE: -O-A.SLIREVISIO A ULTRASONIC: X LIQUID PENETRANT: MAGNETIC PARTICLE:__ VISUAL: DATE: DATE: (of It - t/ f SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. W~~Z2.Le A N08ot.L L DAA S C EA.61 Z'S-rr eD r 1'ScA..A 2, S .~.C Io'LA Ig 4 4 6Av eb ~im LweAýe orr oxote
- -7 Q~
V., tJc'7-ZLE 51C C,:Ai"G AJe&ir OST-AIAIEO 10 07 S-r-o bMoz22LE cL(jLueLA*roiCA. Tc c~eALC Mar~ oil-rAINEO-36I % AJ02.L(e -r KEWAUNEE NUCLEAR /1*1 POWER PLANT REVIEW:
- . X1DATE:4,L, AUTHORIZED NUCLEAR INSER VICE INSPECTOR REVIEW:
14-DATE:____________ EXAMINER: EXAMINER: Q-LEVEL LEVEL I I I I
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: 2-i C kQ,r. Lcop DRAWING NO.: ISUfl-3 COMPONENT IDENTIFICATION: RL-V7ý)TWA PROCEDURE: t4 St'4r REVISION: A ULTRASONIC: K LIQUID PENETRANT:__ MAGNETIC PARTICLE:__ VISUAL: EXAMINER: yd_* DATE: -'-0 LEVEL EXAMINER: DATE: O /La Itq/01 LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. I Ir Mozz.Le ce=*,jF,.-,..t,-*'ztcf Limmrs e-QJ9T*-t.6-Litri-I I I -Fo-rAAI I-N E6 CI g-A11E KEWAUNEE NUCLEAR -s POWER PLANT REVIEW: / DATE: \\el, ;aOO AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: DATE: 6.-o/
WISCONSIN PUBLIC SERVICE CORPORATION IREV.: ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT: iG g 0-ooLA.-- iP,. Loop i* DRAWING NO.: LSI6-fl0H COMPONENT IDENTIFICATION: Z-L-LW-SClm PROCEDURE: 1'JED -iS-. 1 4r REVISION: P" ULTRASONIC: X LIQUID PENETRANT:__ MAGNETIC PARTICLE:__ VISUAL: EXAMINER:
- E.L:"7 DATE:
-/5" -"."_/ LEVEL EXAMINER: -*( O-. - DATE: _____r____ "LEVEL SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. MJbZ.ZL CosIFi~ot*. tOuj.-r0 Li ritS Co',.d64Aw, %,41' 0*, L4S"*.,AJ Z,3",l, A.m,. asl 2,,-,,4,10 8 SAPE e'ob sILE c*meeAL-R io"r 'TAzJ-A: 2o.3,/., N.JZZLE 5 1 NE Ar::4C( t--
- ,-A,*AI
/0 o/0, KEWAUNEE NUCLEAR ,9j POWER PLANT REVIEW: J J DATE: "11,1001 AUTHORIZED NUCLEAR INSERVICE INSPECTOR REVIEW: DATE: -9_-_/
WISCONSIN PUBLIC SERVICE CORPORATION IREV ORIG. KEWAUNEE NUCLEAR POWER PLANT ULTRASONIC, LIQUID PENETRANT, MAGNETIC PARTICLE AND VISUAL EXAMINATION LIMITATION TO EXAMINATION RECORD SYSTEM OR COMPONENT:
- C--a--
c-o,ý,,L-e-r 00 '-ooP DRAWINGNO.: ISIM--1o4 COMPONENT IDENTIFICATION: _ - '-Y1 bI4 PROCEDURE: ?4A*P-1*. 4f-REVISION: ULTRASONIC: X LIQUID PENETRANT: MAGNETIC PARTICLE: VISUAL: EXAMINER: Q: P t EXAMINER: N q LEVEL
- 7 DATE:
-_1_ -__-- LEVEL DATE: oe,/o, SKETCH TO PROVIDE: APPROXIMATE SIZE, LOCATION, ORIENTATION, TYPE OF LIMITATION AND PERCENTAGE OF REDUCED EXAMINATION COVERAGE. -sApt-e)JD ND'47-tF-uj,"tc LIAi T S CXJOtAbe uji-iT1 eI, '-'s* ,,,, 2,S,1., ,a 7 8..nOD Z,.1, 8AmC 8 SAPE eA4LO SILE CbJEAAEF AJCr oZ-lAiAJ9,8: 20.314, INThZ.Le
- >161E c-qR~ý IgOT- 0rAiAJEO. 1001.,
-rcrrA. ccovEeA~ Ajar o~gAweaJ F-m KEWAUNEE NUCLEAR POWER PLANT REVIEW: DATE: llfa7 AE AUTHORIZED NUCLEAR \\1 INSERVICE INSPECTOR REVIEW: DATE:_____._- __ I I}}