Abnormal Occurrence 75-37:on 751021,blocked Strainer on Outlet of Boric Acid Mixtank Decreased Flow Rate.Plant Shutdown Followed to Replace Strainer.Plant Returned to Svc in 15 Minutes
ML19210A197
Person / Time
Site: Three Mile Island Constellation icon.png
Issue date: 10/21/1975
From: Colitz J
METROPOLITAN EDISON CO.
To:
Shared Package
ML19210A192 List:
References
NUDOCS 7910240917
Download: ML19210A197 (1)


Text

. - _ . ___

s

! N , .MP ~*'.b(-.;7,y l

g -

i -

/

l.METROPOLITAN EDISON COMPANY suworsav or cenessa. rueuc urturoes coaronarion

] POST OPPICE BOX 480 MfDDLETOWN. PENNSYLVANIA 17057 TELEPHONE 717 944 4041

]

, h October 21. 1975

7 i 1 J Mr. J. P. O'Reilly. Director h ,1 Directorate of Regulatory D 3'

Region I 631 Park Avenue '

b 2 King of Prussia. Pa.. 19406 I

l Operating License DPR-50

Docket 50-289

Subject:

Abnormal Occurr2nce No. A0 75-37

Dear Mr. O'Reilly:

[ This telegram is to confirm the conversation between Mr. Lee Spessa'rd I (Region I-URC) and Mr. J. J. Colitz (TMI-Unit 1 Superintendent) at 4915 ..

! hours on October 21. 1975.

The following report is submitted in accordance with paragraph 6.7.2a.1 (page 6-11) of the Technical Specifications.

[

On October 21, 1975, tne Boric Acid Mix Tank was <fesignated as the tank to meet Tech. Spec. 3.2.2 requirements.

! While boric acid was being transferred from the Boric Acid Mix Tank to a i Reclaimed Boric Acid Storage Tank, the cocinon suction strainer for the I Boric Acid Pumps collected sufficient fines to partially obstruct the flow

) of beric acid.

1 Since the Boric Acid Mix Tank was the Tech. Spec. Tank, the strainer change-

cut necessitated removing the tank from operable status for approximately 15 a minutes. During this time period, a reduction in plant power was conanenced.

The strainer was replaced within approximately 15 minutes and the Boric Acid l Mix Tank and addition system was declared operable per Tech. Spec. 3.2.2.

The power reduction was then tennicated and the plant restored to the l

previous power level.

s l Very truly yours.

l r

.g I . . Cali Unit 1 Superintendent r, . mom gg10%d 1476 196

.