ST CFFICti BOX 400 MIDDLETOWN. PENNGYLVANIA 17057 TELEP HON E 717.W-4041 July 11, 1975
!!r. J. P. O'Reilly. Director grgoraqq!p'ig D
fi g Directorate of Resulatcry D {' g J Region 1 o J ce G31 Park fezanne King of Prussia, Pa.,
19606 Operating License DPR-50 Docket 50-289
Subject:
Abnormal Occurrence fio. 1.0-75-25.
Dear Mr. O'Reilly:
This telegram is to confim the telecon with Paul Kellogg (P.cgion I-URO) und J. P. O'r!anlon (T!!I Unit 1 Plant Operations !?eview Comnittee Chaiman) ct 1515, July 11,1975.
The folicwing report is submitted in accordance with paragraph 6.7.2.a.2 (pcgo 6-11) of the Technical Specifications.
On July 11. 1975, during a routine inspection of the Auxiliary Building, two pin hele leaks were fcund in sccket wcld joints of the
'%" Make-Up Pump suc0f en line vent. This is considered en chacrmal hgredation of a boundary designed to contain radioactive liquid.
The leaks have been repaired and a hydro will be perfomed on the vent iina.
The leakage appears to be a result of vibration in the make-up pump suction line being transmitted to the rigidly supported vent line.
The support schece of the vent line has been changed to allow for greater ficxibility of the line.
Very truly yours, b,Q