j Gl'.f2.Q!i.,W/

,3

- - - - - = -

METROPOLITAN EDESON COMPANY sussroianvor centaat.rueucununescoarosanc.s POST OFFICE BOX 480 MIDDLETOWN.PENNSY;.VANIA 17057 TELEP HON E 717-9i84-4041 June 25,1975 D

  • On 3. <@" ' S ' o rlp n g.

Mr. J. P. O'Pel11y, Director th i,

Directorate of Regulatory. Operations Region 1 o ML 1

' d, SU a

.o 631 Park Avenue King of Prussia. Pennsylvania 19406 Operating License CPR-50 Docket 50-289

Subject:

Abnormal Occurrence No. A0-75-21

Dear tir. O'Reilly:

This telegrara is to confim the telecon between Bert Davis (Region 1-tRO) and J. J. Colitz (Til! Unit 1 Superintendent) at 1700 beurs, June 25, 1975.

Violation of Technical Specification 2.3.1 in that the high reactor coolant teraperature trip bistable for Reactor Protection System Channel C failrd to trip during routine P.PS Surveillance Testing. Table 2.3-1(Page 2-9) of the Tecnnical Srccification requires that the bistable trip at a marimun tenperature of 619"F.

T^ne bistable failed to trip because.s carpenent failure in the signal converter prevented the trip signal from reaching the.bistabl,e.

The high temperature trip feature for the remaining three RPS channels was imediately checked and the bistables were found to trip within Technical Specification limits.

The def ective signal converter is currently under repair. Upon completion of repairs, the high temperature trip feature will be ccmpletely tested prior to returning APS Chcnnel C to service.

Very truly yours.

. Coli z tinit 1 Superintendent TMI Nuclear Station JJC:YPfhth

^

~

}47h 27[ f I

q910MO