Pages that link to "PNO-I-86-034, on 860424,plant Shut Down Due to Main Turbine Drain Line Steam Leak from Turbine Control Valve Header. Caused by Failed Weld at Socket Joint.Repairs Being Performed.Commonwealth of PA Notified"
Jump to navigation
Jump to search
The following pages link to PNO-I-86-034, on 860424,plant Shut Down Due to Main Turbine Drain Line Steam Leak from Turbine Control Valve Header. Caused by Failed Weld at Socket Joint.Repairs Being Performed.Commonwealth of PA Notified:
Displayed 50 items.
- ML20197E176 (← links)
- PNO-I-87-023, on 870323,reactor Critical Following 5-month Outage.Remote Shutdown Panel Test Conducted on 870322.Steam Generator Instruments Monitored Due to Lack of Agreement (← links)
- ML20205J223 (← links)
- ML20205H271 (← links)
- ML20203L314 (← links)
- ML20203K945 (redirect page) (← links)
- PNO-I-86-034 (redirect page) (← links)
- ML20203J182 (← links)
- ML20203G323 (← links)
- ML20203G294 (← links)
- ML20203G258 (← links)
- PNO-I-88-075, on 880720,results of Independent Investigation Re Operator Sleeping on Duty Announced.Disciplinary Actions Including Dismissal,Reassignments to Lower Positions & Formal Reprimands Made Effective on 880719 (← links)
- ML20213D194 (← links)
- ML20213D180 (← links)
- ML20213D176 (← links)
- ML20213D175 (← links)
- ML20213D172 (← links)
- ML20213D170 (← links)
- PNO-I-87-006, in Dec 1986,licensee Informed Region I of Investigation of Employee Allegation Re Drug Use at Facility.Alleger Implicated 14 People.One Individual resigned,3 Tested Positive & 10 Cleared After Testing (← links)
- ML20212D924 (← links)
- ML20244C641 (← links)
- ML20244A594 (← links)
- ML20244A588 (← links)
- ML20249C806 (← links)
- ML20249B211 (← links)
- ML20249B033 (← links)
- ML20249A934 (← links)
- ML20249A825 (← links)
- ML20248J810 (← links)
- ML20248H649 (← links)
- PNO-I-89-081, on 890925,two Laborers Inadvertently Handled Core Debris That Could Have Resulted in Overexposure. Detailed Assessment Performed by Licensee to Establish Time Individuals Handled Source & Actual Doses Received (← links)
- ML20248F209 (← links)
- ML20248F192 (← links)
- PNO-I-89-056, on 890710,reactor Vessel Lower Head Cracks from Guide Tubes E-7 & G-6 Discovered.Tubes Substantially Damaged by Flow of Molten Fuel.Investigation & Cleanup Started (← links)
- ML20236X024 (← links)
- ML20236V901 (← links)
- ML20236U439 (← links)
- ML20236U059 (← links)
- ML20236P997 (← links)
- ML20236F116 (← links)
- PNO-I-87-063, on 870709,NRC & Util Received Anonymous Allegation Re Shift Supervisor Sleeping on Duty.Makeshift Beds Identified & Dismantled & Three Contract Employees Terminated for Sleeping Onsite (← links)
- ML20216J890 (← links)
- PNO-I-87-063A, on 870710,special Insp Team Dispatched to Facility to Review Licensee Efforts Re Allegations of Sleeping on Duty.Random Offshift Insp Identified No Evidence of Operators Inattention to Duties (← links)
- PNO-I-87-049B, on 870612,NRC Informed That Confirmed Positive Drug Test Results Received on 10 Employees.One Employee Fired,One Reassigned & Eight Suspended.Positive Results for Licensed Operators or Mgt Personnel Not Received (← links)
- PNO-I-87-055, on 870612,reactor Shut Down Due to Increased Leakage from Letdown Cooler A.Letdown Cooler Will Be Replaced During 1-month Outage (← links)
- PNO-I-87-049A, updates Licensee Drug Investigation at Facility.Licensee Not Releasing Details to Media or Public Due to Ongoing Investigation.Notification Issued on 870601 Contained Typo.Actual Date of Notification Should Be 870519 (← links)
- ML20214R515 (← links)
- ML20211P921 (← links)
- ML20210C719 (← links)
- PNO-I-88-084A, on 880829,resident Inspectors Informed of Results of Drug Testing on Licensee Reactor Operator Involved in Altercation Described in PNO-I-88-084.Licensee Terminated Employee on Basis of Positive Test Results (← links)