tl      s,                                                            December 4, 1997
    ' c-s
      .              Mr. James P. O'Hanlon Senior Vice Presidut Nuclear c      - Virginia Electric ar*.d Power Company Innsbrook Technical Center -
5000 Dominicn Boulevard Glen Allen, VA 23060
 
==SUBJECT:==
REQUEST FOR ADDITIONAL INFORMATION (RAI) CONCERNING THE APPLICATION FOR THE NORTH ANNA INDEPENDENT SPENT FUEL                                            ,
STORAGE INSTALLATION (TAC NO. L22113)
 
==Dear Mr. O'Hanlon:==
 
        -            By letter dated May 9,1995, you submitted an application to the Nuclear Regulatory                                                  '
Commission in accordance with 10 CFR Part 72 for the review and approval of a siteispecific                              ;
license for an independent spent fuel storage installation (ISFSI) at the North Anna Nuclear Power Station site. Your application included proposed technical specifications (TS) for the North Anna ISFSI.
  -            - The staff continues to review your proposed TS and is considering an initiative to modify ISFSI .                  '
                    ' TS to be consistent with the form and content of the improved Standard Technical
                  , Specifications (ITS) for operating reactors. As part of this initiative, the staff has reformatted f Virginia Power's proposed North Anna ISFSI TS according to the ITS format. A copy of the ~                                  '
  ,                  staff's draft reformatted North Anna ISFSI TS is enclosed.
,                    The staff is continuing an aggressive internal review of the reformatted TS, drawing on staff                                      ,
experience gained with the operating reactor ITS program. The staff requests that you review
                  > the enclosed reformatted TS and provide comments and proposed changes regarding both form                                      .
and content by January 30,1998, in addition, please prepare appropriate TS bases using the depth of detail and format of the ITS bases as a guide.
If you have any comment or question concerning this request, please contact me at 301-415-1309.
Sincerely,
[ original signed by /s/j Joseph W. Shea, Project Manager Spent Fuel Licensing Section Spent Fuel Project Office Office of Nuclear Material Safety                          g and Safeguards                                        gg q Docket No. 72-16 (50-338/339)                                                                            i
 
==Enclosure:==
Draft Reformatted North Anna ISFSI TS g[I cc: Service List Destnbution. (Control No. 010S)
Docket ~          NRC File Center          PUBLIC .__                        NMSS r/f          SFPO r/f SFLS r/f          CHaughney                SShankman                        WReamer.OGC KCleu                        <
EKeegan -        SO' Conner                NKa!yanam NRR                    WGloerson, Ril                          /
OFC        SFPO            b  SFPOY''            b  SFPO                    6-    SFPO              -
NAME      JSheahbfh                rpe                FSturz r,vr*1 N                EJLeeds  8
                        -DATE        11/2bh              114b/97                ,t JI /97                      MJ3 C = COVER E = COVER & ENCLOSURE N = NO COPY OFFICIAL RECORD COPY GSNORTH_AN\L22113.RA3 9712120235 971204                                          1 l      Igl      'I l llll      J PDR        ADOCK 05000338                                    .a a]
ll1  ]l..lul. jl v                    _en                                                          .lhl.-l .
 
__ _          -_              , _.              -    . _ _ _ _ - ___ _ _                        .~_____        _      ._
3;      .A                                                                                                                            '
Mr..J.PI0'Hanlon                    -
North Anna Power Station
                        - Virginia Electric & Power Company.                              Units 1 and 2 CC;'
Mr. William C. Porter. Jr.                                      Regional Administrator.. Region 11-County Administrator                                            U.S. Nuclear Regulatory Commission Louisa County                                                  Atlanta Federal Cer.ter P.O. Box 160                                                    61 Forsyth-St. SW. Suite 23T85 Louisa. Virginia 23093                                        Atlanta.-Georgia 30303 3415 Michael W. Maupin Esquire                                      Mr. W. R. Mdtthews, Manager
.                        Hunton and Williams                                            North Anna Power Station
                        - Riverfront Plaza. East. Tower                                  P. 0. Box 402 951 E. Byrd Street                                              Mineral. Virginia 23117 Richmond, Virginia 23219.
Mr. Al Belisle                    ..
Dr. W. T. Lough                                                U.S. Nuclear Regulatory Comission
:                        Virginia State Corporation                                    Atlanta Federal Center Commission                                                  61 Forsyth St., SW. Suite 23T85 Division of Energy Regulation                                  Atlanta. Georgia 30303 3415 P. O. Box 1197 Richmond, Virginia 23209                                      Mr. David Christian Manager Surry Power Station Old Dominion Electric Cooperative                              Virginia Electric and Power Company 4201. Dominion Blvd.                                          5570 Hog Island Road
                        . Glen Allen. Virginia 23060                                    Surry, Virginia 23883 Mr. James H. McCarthy. Manager                                Mr. J. P. O'Hanicn Nuclear Licensing & Operations                                  Senior Vice President - Nuclear Support                                                    Virginia Electric and Power Company Virginia Electric and Power Company                            Innsbrook Technical Center Innsbrook Technical Center                                    5000 Dominion Blvd.
5000 Dominion Blvd.                                            Glen Allen. Virginia 23060 Glen Allen. Virginia 23060 Office of the Attorney General Commonwealth of Virginia
  ,                      900 East Main Street Richmond Virginia 23219 i
Senior Resident Inspector North Anna Power Station U.S. Nuclear Regulatory Comission 1024 Haley Drive Mineral. Virginia -23117 2                        . Robert.B. Strobe M.D.. M.P.H.
                        . State Health Commissioner Office of the Commissioner Virginia Department of Health P.O. Box 2448 Richmond, Virginia 23218 d
ym              ei. w. y      - --pid-    y y - a Ir'  -  D-    e                                              -    w  - I eE
 
9        g Draft Reformatted North Anna ISFSI TS Enclosure
 
4            .4                                                                                                                !
                        .                                                                                    Definitions              i
            .                                                                                                        1.1              !
1,0 USE AND. APPLICATION 1,1 Definitions
                            ....................................          NOTE---------------- --------------------
The defined terms of this section ap ear in capitalized t pe and are applicable throughout these Technica Specifications and ases.
Term                                Definition ACTIONS                              ACTIONS shall be that part of a Specification that prescribes Required Actions to be taken under designated Conditions within specified Completion Times.
LOADING OPERATION                    Loading operations include all SSSC preparation steps before SSSC transport from the-Decontamination Building.
OPERABLE-OPERABILITY                A system, subsystem. division, com>onent, or device shall be OPERABLE or have 0)ERABILITY when it is capable of aerforming its specified safety function (s) and w1en all necessary attendant instrumentation, controls, normal or emergency electrical power, cooling and seal water, lubrication, and other auxiliary equipment that are required for the system, subsystem, division, component, or device to perform its specified safety function (s) are also capable of performing their related support function (s).
i North Anna ISFSI                              1.1-1                      Amendment No.
 
l
              .                                                                  . Logical Connectors
  *- .                                                                                          1,2 1.0 USE AND APPLICATION 1.2 Logical Connectors 4
PURPOSE              The purpose of this section is to explain the meaning of logical connectors.
,                                    Logical connectors are used in Technical Specifications (TS) to discriminate between, and yet connect, discrete Conditions, Re Surveillances,and  quired Actions. Completion Times,The only logical c Frequencies.
that appear in TS are BlQ and 2. The physical arrangement of these connectors constitutes -logical conventions with specific meanings.
BACKGROUND          Several levels of logic may be used to state Required Actions. These levels are identified by the placement (or nesting) of the logical connectors and by the number assigned to each Required Action. The first level of logic is identified by the first digit of the number assigned to a Required Action and the placement of the . logical connector in the first level of nesting (i.e., left justified with the number of the Required Action). The successive levels of logic are identified by additional digits of the Required Action number and by successive indentions of the logical connectors.
When logical connectors are used to state a Condition.
Completion Time, Surveillance, or Frequency, only the first level of logic is used, and the logical connector is left justified with the statement of the Condition, Completion Time, Surveillance, or Frequency.
EXAMPLES            The following examples illustrate the use of logical connectors.
,                                                                                        (continued)
North-Anna ISFSI                          1,2-1                    Amendment No.
 
      - n    .
s-.. n ..-~  ..x      -      . , - -      _n  - ,. - . . . - -        . . ~    . -      _  .~-a.. . - - - -
<,    s,
  ^
Logical Connectors 1.2 1.2 Logical Connectors EXAMPLES                EXAMPLE 1.2-1 (continued)
ACTIONS CONDITION                    REQUIRED ACTION                  COMPLETION TlHE A. LCO not met.          A.1 Verify . . .
68D A.2 Restore . . .
I                          __.
In this example the logical connector LN) is used to indicate that when in Condition A, both Required Actions A.1 and A.2 must be completed.
                                                                                                      .      (continued)
North Anna ISFSI                                    1.2 2                                  Amendment No.
 
            .                                                                                                              Logical Connectors 1.2 1.2 Log $ a' Connectors EXAMPLES          EXAMPLE 1 2-2 (continued)
ACTIONS CONDITION                          REQUIRED ACTION                      COMPLETION TiliE A. LCO not met.                A.1            Trip . . .
A.2.1          Verify . . .
RfD A.2 2.1 Reduce . . .
A.2.2.2 Perform . . .
A.3            Align . . .
This example represents a more complicated use of logical connectors. Required Actions A.I. A.2 and A.3 are alternative choices only one of which must be performed as indiccted by the use of the logical connector @ and the leftjustified                                  Any one of these three Actions may be chosen.If placement. A.2 is chosen then both A.2.1 and A.2.2 must be performed as indicated by the logical connector MiQ.
Required Action A.2.2 is met by performing A.2.2.1 or A.2.2.2,      The indented position of the logica: connector
                                            @ indicates that A.2.2.1 and A.2.2.2 are alternative choices, only one of which must be performed.
North Anna ISFSI                                  1.2 3                                          Amendment No.
                                              ,          -y .-a.,    e .w,-=,we-gg      --    ,        + - -        -          .es---y+-    v- -*-r,
 
y              *,
                      -        .                                                                                                                                                    Completion Times -
                  .                                                                                                                                                                                                      13      ;
1.0 USE AND APPLICATION                                                                                                                                                            !
1.3 Completion Times f
I
                                            ' PURPOSE              The purpose of this section is to establish the Completion Time convention and to provide guidance for its use.                                                                                                          :
BACKGROUND            LimitingConditionsforOperation(LCOs)specifyminimum.                                                                                                          :
requirements for er.suringaafe operation of the unit. The ACTIONS associated with an LC0 state Conditions that typically describe the ways in which the requirements of the                                                                                                  .
LCO can fail to be met. Specified with each stated Condition are Required Action (s) and Completion Times (s).
DESCRIPTION          The Completion Time is the amount of time allowed for completing a Required Action. It is referenced to the time                                                                                                    <
of discovery of a situatun (e.g., inoperable equipment or                                                                                                    !
variable not within limits) that requires entering an                                                                                                        '
ACTIONS Condition unless otherwise specified, providing the unit is in a specified condition stated in the Applicability of the LCO. Required Actions must be completed prior to the expiration of the specified Completion Time. An ACTIONS Condition remains in effect and the Required Actions apply until the Condition no longer exists or the unit is not
                                                                  -within the 100 Applicability.                                                                                                                                ,
Once a Condition has been entered subsequent divisions.
Subsystems. components, or variables expressed in the Condition, discovered to be inoperable or not within limits.
will ng1 result in separate entry into the Condition unless                                                                                                  .
specifically stated. The Recuired Actions of the Condition continue to apply to each adcitional failure, with Completion Times based on initial entry into the Condition.
(continued) i 4
I 4                                            North Anna ISFSI                                              1.3 1                                                                    Amerdment No.                              .
  , - , , . . ,                  , , , . -        , . , .          ,-                ,. . , , - - . , -      . . , . , , , , , . , . - . . , . - , . , . . . - , , - - - . , ,          ,,..,,,,nn,.,,.,-,.,.,na,.    . . ,
 
9            t 4
Completion Times      f 1.3 I
1.3 Completion Times DESCRIPTION                                However, when a subseauent division, subsystem, component.
(continued)                        or variable expre.ssed in the Condition is discovered to be inoperable or not within limits, the Completion. Time (s) may be extended. To apply this Completion Time extension. two criteria must first be met. The subsequent inoperability:
: a. Must exist concurrent with the ,tjrit inoperability:
  ,                                                                                and
: b. Must remain inoperable or not within limits after the first inoperability is resolved.
The total Completion Time allowed for completing a Required Action to address the subsequent inoperability shall be y
limited to the more restrictive of either:
.                                                                          a. The stated Completion Time. as measured from the initial entry into the Condition, plus an additional                i
;                                                                                24 hours: or
: b. The stated Completion Time as measured from discovery of the subsequent inoperability.
The above Completion Time extension does not ap)1y to a Completion Time with a modified " time zero." T11s modified
                                                                            " time zero" may be ex)ressed as a repetitive time (1-.e..
                                                                            "once per 8 hours." w1ere the Completion Time is referenced from a previous completion of the Required Action versus the time "fromofdiscovery Condition    . .entry)
                                                                                                          ."    Example 1.3 3 illustrates one use ofor a this type of Completion Time. The 10 day Completion Time specified for Condition A and B in Examp!e 1.3 3 may not be extended.
(continued) i North Anna ISFSI                                                      1.3 2                      Amendment No.
0 w    y ,--  .m.,        . , , - -    ,,,m.-  -  w..-_          , ,-        .--r, _ , - . ,          .~,,-,-,-m.,,.%-.
 
9      '<
Completion Times 1.3 I
1.3 Completion Times (continued) l l
EXAMh.ES          The following examples illustrate the use of Completion Times with different types cf Conditions and changing                                  ;
Conditions.
EXAMPLE 1 3 1 ACTIONS CONDITION              Rf.0VIRED ACTION            COMPLETION TIME B. Required                B.1 Perform Action            12 hours Action and              B.1 associated Completion        M Time not met.              B.2 Perform Action            36 hours B.2 Condition B has two Required Actions.            Each Required Action has its own separate Completion Time.            Each Completion Time is referenced to the time that Condition B is entered.
The Required Actions of Condition B are to be complete action B.1 within 12 hours @ complete action B.2 within 36 hours. A total of 12 hours is allowed for com action B.1 and a total of 36 hours (not 48 hours)pleti.10is allowed for completing action B.2 from the time that Condition B was entered. If action B.1 is completed within 6 hours the time allowed for completing action B.2 is the next 30 hours because the total time allowed for completing action B.2 is 36 hours.
                                    ..                                                                  (continued)
North Anna ISFSI                                1.3 3                          Amendment No.
 
Completion Times
    .                                                                                        1.3 1.3 Completion Times EXAMPLES          EXAMPLE 1.3 2 (continued)
ACTIONS CONDITION        REQUIRED ACTION      COMPLETION TIME A. One system      A.1 Restore system to    7 days inoperable.          OPERABLE status.
B. Required        B.1 Complete action      12 hours Action and            B.1 associated Completion    Aj@
Time not                                36 hours met.          B.2 Complete action B.2 When a system is declared inoperable, Condition A is entered. If the system is not restored to OPERABLE status within 7 days. Condition B is also entered and the Completion Time clocks for Required Actions B.1 and B.2 start. If the inoperable system is restored to OPERABLE status after Condition B is entered. Condition A and B are exited, and therefore, the Required Actions of Condition B may be terminated.
North Anna ISFSI                      1.3 4                      Amendment No.
l
 
I s
Frequency 1.4 1.0 USE AND APPLICATION 1.4 Frequency I                                PURPOSE                            The purpose of this section is to define the proper use and application of Frequency requirements.
DESCRIPTION                        Each Surveillance Requirement (SR) has a specified frequency in which the Surveillance must be met in order to meet the 1
associated Limiting Condition for Operation (LCO). An understanding of the correct application of the specified frequency is necessary for compliance with the SR.                  . ,
The "specified Frequency" is referred to throughout this section and each of the Specifications of Section 3.0.
Surveillance Requirement (SR) Applicability. The "specified Frequency" consists of the requirements of the Frequency              ;
:                                                                    column of each SR, as well as certain Notes in the                    :
;                                                                    Surveillance column that modify performance requirements.
Sometimes special situations dictate when the requirements of a Surveillance are to be met. They are "otherwise stated" conditions allowed by SR 3.0.1. They may be stated as clarifying Notes in the Surveillance, as part of the Surveillance, or both. Example 1.4-4 discusses these
;                                                                    special situations.
Situations where a Surveillance could be required (i.e., its Frequency coula expire), but where it is not possible or not desired that it be performed until sometime after the associated LCO is within its Applicability, represent potential SR 3.0.4 conflicts. To avoid these conflicts, the SR (i.e., the Surveillance or the Frequency) is stated such that it is only " required" when it can be and should be performed. With an SR sotisfied. SR 3.0.4 imposes no restriction.
The use of " met" or " performed" in these instances conveys specific meanings. A Surveillance is " met" only when the acceptance criteria are satisfied. Known failure of the
.                                                                    requirements of a Surveillance, even without a Surveillance specifically"being " performed." constitutes a Surveillance not " met."    Performance" refers only to the requirement to specifica'ly determine the ability to meet the acceptance
                                                                                                                          - (continued)
North Anna                                              1.4 1                    Amendment No.
n'*
 
v    o Frequency 1.4 1.4 Frequency DESCRI." TION criteria. SR 3.0.4 restrictions would not apply if both the (continued) following conditior.s are satisfied:
: a. The Surveillance is not required to be performed; and
: b. The Surveillance is not required to be met or, even if required to be met is not known to be failed.
EXAMPLES      The following examples illustrate the various ways that Frequencies are specified.
EXAMPLEiJ.:.'.
SURVEILLANCE REQUIREMENTS SURVEILLANCE                      FREQUENCY              ,
Perform CHANNEL CHECK.                      12 hours Example 1.4 1 contains the type of SR most often encountered in the Technical Specifications (TS). The Frequency specifies an interval (12 hours) during which the associated Surveillance must be performed at least one time.
Performance of the Surveillance initiates the subsequent interval. Although the Frequency is stated as 12 hours, an extension of the time interval to 1.25 times the interval specified in the frequency is allowed by SR 3.0.2 for operational flexibility. The measurement of this interval continues at all times, even when the SR is not required to be met aer SR 3.0.1 (such as when the equipment is inoperaale, a variable is outside specified limits, or the unit is outside the Applicability of the LCO). If the interval specified by SR 3.0.2 is exceeded while the unit is in a condition specified in the Applicability of vne LCO.
and the performance of the Surveillance is not otherwise modified (refer to Examples 1.4 3 and 1.4 4), then SR 3.0.3 becomes applicable.
(continued)
North Anna                        1.4-2                    Amendment No.
 
Frequency 1.4 1.4 Frequency EXAMPLES'                            EXAMPLE 1 4 1    (continued)
If the interval as specified by SR 3.0.2 is exceeded while the unit is not in a condition specified in the Applicability of the LCO for which performance of the SR is required, the Surveillance must be performed within the Frequency requirements of SR 3.0.2 prior to entry into the specified condition. Failure to do so would result in a violation of SR 3.0.4.
EXAMPLE 1.4-2 SURVEILLANCE REOUIREMENTS SURVEILLANCE                    FRE0VENCY Verify flow is within limits.              Once within 12 hours prior to starting activtity M
24 hours thereafter Example 1.4-2 has two Frecuencies. The first is a one time performance Frequency, anc the second is of the type showT) in Example 1.4 1. The logical connector "E" indicates that both Frequency requirements must be met. Each time the example activity is to be performed, the Surveillance must be performed within 12 hours prior to starting the activity.
The use of "once" indicates a single performance will satisfy the specified Frequency (assuming no other Frequencies ~are connected by " E "). This t pe of Frequency does not qualify for the extension allowed b SR 3.0.2.
(continued) f North Anna                                                1.4-3                    Amendment No.
 
I                                                                                                                                                  Frequency 1.4 1.4 Frequency EXAMPLES                                        EXAMPLE 1.4 2 (continued)
                                                                "Thereafter" indicates future performances must be established per SR 3.0.2. but only after a specified condition is first met (i.e., the "once" performance in this example).                                  If the specified activity is cancelled or not performed, the measurement of both intervals stops. New intervals start upon preparing to restart the specified activity, i
North Anna                                                                                      1.4-4                  Amendment No.
 
                - . .                                                                                                                                                                          SLs 2.0 2.0 SAFETY LlHITS (SLs)                                                                                                                                                      i 2,1 SLs                                                                                                                                                                      !
                                              - 2.1.1 Fuel To 3e Stored At The ISFSI                                                                                                                            l The spent nuclear fuel to be stored in SSSCs at the North Anna ISFSI shall meet the following requirements:
(1)                  Only fuel assemblies irradiated at the North Anna Power Station Units 1 and 2 may be stored.
(2)                  Fuel assemblies shall be intact. Partial fuel assemblies, that i                                                                    is, fuel assemblies from which fuel rods are missing must not be loaded in SSSCs unless dummy fuel rods are used to displace an-amount of water equal to that displaced by the original fuel rods.
(3)                  Fuel assemblies known or suspected to have structural defects or gross cladding failures sufficiently severe to adversely affect                                                                            i fuel handling and transfer capability shall not be loaded into                                                                            !
SSSCs for storage.
(4)                  Fuel assemblies shall meet the limits for initial enrichment.
;                                                                    average burnup, deca heat, and cooling time after reactor                                                                                  j discharge as specifi d in Table 2.11 4
i 1
NORTH ANNA ISFSI                                                            2.0 1                                        Amendment No.
t
    ,yvew av,- y  ,.-          g--t-iy-~  ,ywe  yqsiy,iy-q.-'-y      e
                                                                          .g er g w    p.e--& r-M  i      s. e w    v1mme Ve pw V    ww h,w.+em1m-w---s-i      =e,ei-ds-c-  .=-ms'-i-- * *w+  rs -  #''v'-
 
SLs 2.0                              ;
i J
2.2 SL Violations With any SL violation. the following actions shall be completed:
2.2.1 Within 24 hours, notify the NRC Operations Center.
2.2.2 Within 24 hours, notify the Plant Manager and the Vice President-Nuclear Engineering.
f 2.2.3 Within 30 days, a written report, similar to a Licensee Event Report (LER) in 10 CFR 50.73, shall be prepared and submitted to the NRC.
2.2.4 Continued loading of SSSCs shall not be resamed until authorized by the NRC.
s NORTH ANNA ISFSI                                                                        2.0 2                                      Amendment No, d
i
            .e,,      ,. .. .-  e-e-.,  w %-,            ,eween -owassrmy--e n . _        ._r--w -
me =mawwwe,,,w,--.                .<,-n.  --~._en,-7 o            . . _ .                    = , . . . _
 
y          S
        .                                                                                                                                                                SLs 2.0 febte 2.1 1 Fuel Assembly Characteristics
                                      $55C N@EL                                                                        ALLOWABLE VALUE
: 1. TN 32
: e. Inittel Enrichment                                                                  g 3.05 wt. I
: b. Averece herup                                                                      3 0,000 4      thC/MTU
: c. Cooline fime Af ter                                                                g 7 yeare Discherpo
: d. Decay koet                                                                          3 0.N 3 km/sonesbly
: e. TN Peremeter/ Power                                                                      700 Density NORTH ANNA ]SFSI                                            2.0 3                                                        Amendment No.        ,
v-*        --__________ _.        _  _ _ . _ _ -a _ , _ _ _. - , _ - _._6        -4  -rm e + , w w- e  ewm, eseeve      -nu      , -y e wzewe~,e--    wes. --+e-+ -
 
LCO-Applicability-                      l 3.0 3.0 LIMITING CONDITION FOR OPERATION (LCO) APPLICABILITY J
LCO 3.0.1-        LCOs shall be met during specified conditions in the                                    i
:                                Ap)licability, except as provided in LCO 3.0.2 and LC0 3.0.7.                                                                              ,
LCO 3.0.2        0 on discover A!tionsofth of aassociated failure to Conditions meet an LCO.
shall the Required be met. except' as provided in LC0 3.0.5 and LC0 3.0.6, If the LCO is met or is no longer applicable prior to expiration of the specified Completion Time (s), completion of the Required Action (s) is not required, unless otherwise stated.
LC0 3.0.3        Deleted for ISFSI 15 LC0 3.0.4        When an LC0 is not met, entry into a specified condition in 4
the Applicability shall not be made except when the                                    ,
:                                associated ACTIONS to be entered permit continued operation
;                                in the specified condition in the Applicability for an
:                                unlimited period of time. This Specification shall not prevent changes in specified conditions in the Applicability that are required to comply with ACTIONS.
l              LC0 3.0.5        Equipment removed from service or declared inoperable to i
comply with ACTIONS may be returned to service under
,                                administrative control solely to perform testing required to
:-                                demonstrate its' OPERABILITY or the OPERABILITY of other equipment. This is an exception to LC0 3.0,2 for the system returned to service'under administrative control to perform the testing required to demonstrate OPERAPILITY.
              -LC0 3.0.6          Deleted for ISFSI TS
              ..LC0 3.0.7        Deleted for ISFSI North Anna ISFSI                        2;01                      Amendment'No.
                                                                                        ..,            ,.,=.,.._p n, _ _
 
O                                                                                            SR Applicabilit 3.0 3.0 SURVEILLANCE REOUIREMENT (SR) APPLICABILITY SR 3.0.1                  SRs shall be met during the s>ecified conditions in the Applicability for individual .COs, unless otherwise stated i                                              in the SR. Failure to meet a Surveillance, whether such failure is ~ experienced during the performance of the-Surveillance or between performances of the Surveillance, shall be failure to meet the LCO. Failure to perform a Surveillance within the specified Frequency shall be failure to meet the LCO except as provided in SR 3.0.3.
Surveillances do not have to be performed on inoperable equipment or variables outside specified limits.                              i l
SR- 3.0.2                The specified Frequency for each SR is met if the                            I Surveillance is performed within 1.25 times the interval specified in the frequency, as measured from the previous performance or as measured from the time a specified condition of the Frequency is met.
l For Frequencies specified as *once.* the above interval                      .
extension does not apply. If a Completion Time requires
                                                >eriodic performance on a *once per . . ." basis, the above requency extension a                                                      ;
initial performance. pplies to each performance after the Exceptions to this Specification are stated in the individual Specifications.                                                  ;
SR 3.0.3                  If it is discovered that a Surveillance was not performed within its specified Frequency, then compliance with the requirement to declare the LCO not met may be delayed, from the time of discovery, up to 24 hours or up to the limit of the'specified Frequency. whichever is less. This delay period is permitted to allow performance of the
,                                              wrveillance.
If the Surveillance is not performed within the delay period, the LC0 must imediately be declared not met and the applicable Condition (s) must be entered.-
When the Surveillance is performed within the delay period
'                                            and the Surveillance is not met, the LC0 must immediately be declared not met. and the applicable Condition (s) must be                  >
entered.
(continued)
North Anna'ISFSI                                    3.0 2                        ..nendment' No.
                              . ._ =:  a.        .=,                  -_,
 
          , ..~..__7 _ _ ___ .-__ _
j
: g.        .,                                                                                                                                          i SR Applicability                          !
3.0
.                                                                                                                                                          1 3.0 SR APPLICABILITY (contin td)
SR 3.0.4              Entry into a s>ecified condition in the Applicability of an                                                  .
LCO shall not >e made unless the LCO's Surve111ances have been met within their specified frequency.                          This provision                            ,
shall not prevent entry into specified conditions in the Applicability that are required to comply with ACTIONS.                                                      '
i I
i i
1 L
t 1
i o
l North Anna ISFSI                                        3.0 3                            Amendment No.
    ._              _  .    ._. _ .. m . . - -  _ -      .
                                                                                        . _ _ _ ~  _ _ . _ . .      _ . _ . _ _ . _ _ . .        . - _ -
 
  .                                                                        SSSC Vaccuum Pressure 3.1.1 3.1      SSSC CONFINEMENT INTEGRITY 3.1.1 SSSC Vaccuum Pressure LC0 3.1.1            The SSSC cavity vacuum pressure shall meet the limit specified in Table 3.11 for the applicable SSSC design.
APPLICABILITY;      All SSSC loading operations ACTIONS CONDITION                    REQUIRED ACTION                COMPLETION TIME A. SSSC cavity vaccuum            A.1  Discontinue further          immediately pressure limit not met              loading activity bhD A.2  Restore vaccum system        As soon as or SSSC seal                practical operability 2
A.3  Retirn SSSC to spent        7 days fue4 pool and unload
                                                  ; pent fuel back into pool North Anna ISFS1                        3.1-1                        Amendment No.
 
s,  ..
SSSC Vaccuum Pressure 3.1.1 SURVEILLANCE REQUIREMENTS SURVEILLANCE                                FRE0VENCY SR 3.1.1.1    Verify that the SSSC cavity vacuum pressure        Once during meets the specified limit.                        SSSC loading operations 4
I I
North Anna ISFS!                      3.1 2                      Amendment No.
 
                      +,
9                ,
                          ,                                                                                                                        SSSC Helium Backfill 3.1.2 3.1-      SSSC CONFINEMENT INTEGRITY l
3.1.2 SSSC Helium Backfill Pressure                                                                                                                              l l
LC0 3.1.2                    The SSSC cavity vacuum pressure shall meet the limit-                                                                              <
specified in Table 3.1-1-for the applicable SSSC design.                                                                            l
,                                  = APPLICABILITY:              All SSSC loading operations j                                  ACTIONS                                                                                                                                                        t CONDITION                                              REQUIRED ACTION                            : COMPLETION TIME A. SSSC helium backfill                    A.1                      Discontinue further                        Imediately pressure limit not met                                          loading activity
!                                                                                  OD I
A.2                      Restors helium                            As soon as backfill pressure to                      practical within limits g                                                                                                              ,
A.3                      Return SSSC to spent                      7 days                                      '
fuel pool and unload spent fuel back into
;                                                                                                            pool
* i 4
a t                                                                                                                                                                                                  ,
i
(-
!ij l
North Anna ISFSI                                                        3.1-3                                      Amendment No.                                ,
        ,n- - - . . ,    ,.y.g gw  ,N,,--,,..---,e      e_,,,,-e.,--,.  -  ----,,,,--,,,,,w,,----,--,-,            .,,n--.n, . , , - ,-. ,-,,w-..      - - , , , , , , - - , , , , . , , ,  -
 
SSSC Helium Backfill 3.1.2                ;
                  .                  SURVEILLANCE RE0VIREMENTS I                                                                                                                          SURVEILLANCE                                              FRE0VENCY f
SR 3.1.2.1                                          Verify that the SSSC helium backfill                                                  Once during                                ;
pressure meets the specified limit.                                                  SSSC loading                                ;
operations                                  -
t f
i P
t 1
I I
i i
i I
4 i
i North Ania ISFSI                                                                                3.1 4-                                    Amendment No.
        . . . . -.. . - - . . .                    - - . . . . - - . . . - - - , - . , . , . - . . , . . . . - _ . - . . . - . - - _                                _ - - . .            . . ~ . , , . . . . _ . - _ . -
 
Helium Leakage 3.1.3          ;
3.1_      SSSC CONFINEMENT INTEGRITY                                                                l 3.1.3 Helium Leakage LC0 3.1.3            The total helium leak rate for all closure seals shall not exceed the limit specified in Table 3.1-1 for the applicable SSSC design.                                                                  I APPLICABILITY:      All SSSC loading operations.                                                  !
ACTIONS i
:                          CONDITION                        REQUIRED ALTlt.        COMPLETION TIME A. SSSC helium leakage        A.1          Discontinue further  Immediate1) limits not met                          loading activity MD                                                              :
A.2          Restore helium        As soon as backfill pressure to  practic61 within limits DB A.3          Return SSSC to spent  7 days fuel pool and unload                                :
spent fuel back into                                i pool i
1 i
L                North Anna ISFSI                              3.1-5                  Amendment No.                  :
L      _      _      . .        ._    _    _ _ _ _ __ _ _ _._ ;.__ __ _ _
 
e    **
Helium Leakage 3.1.3 SURVEILLANCE REQUIREMENTS                                                                !
SURVEILLANCE                              FRE0VENCY SR 3.1.3.1      Verify that the SSSC helium leakage meets the specified limit.                            g            n operations 1
I l
North Anna ISFSI                      3.1-6                    Amendment No.
 
      .'                                                                                        SSSC Inter seal Pressure 3.1.4 3.1          SSSC CONFINEMENT INTEGRITY 3.1.4 SSSC INTER-SEAL PRESSURE LC0 3.1.4                  The status indicators for each SSSC on the pressure monitoring alarm panel shall indicate satisfactory closure seal operation.
APPLICABILITY: Each SSSC loaded with fuel at the JSFSt.
ACTIONS CONDITION                                REQUIRED ACTION                  COMPLETION TIME A. Status indicator for                    A.1        Verify that the SSSC            Imediately any loaded SSSC                                    pressure monitoring indicates                                          system is operable, unsatisfactory seal operation                              l@
A.2        If manitoring of the          As soon as reference pressure            practical between SSSC closure seals indicates a loss of 3ressure and seal leatage, return the SSSC to the Decentamination Building and repair or replace the seals, as necessary, to return the SSSC to proper operation.                                                    .
North Anna ISFSI                                          3.1-7                          Amendment No.
 
gs      *e SSSC Inter-seal Pressure 3.1.4 SURVElllANCE REOUIREMENTS SURVEILLANCE                            FREQUENCY SR 3.1.4.1      Verify that the alarm panel status            24 hours indicators for each SSSC indicate satisfactory closure seal operation.
North Anna ISFSI                          3.1 8              Amendment No.
 
3-.,-.-              -.-.
                                        - - . . -. :=      -          - - .-__ . . - . -.. _.. - -                                                        .
SSSC Pressure Monitoring System                                                        !
3.1.5                !
3.1.5 -SSSC Pressure Monitoring System                                                                                                                        f LC0 3.1.5          The SSSC pressure monitoring system shall be operable and shall monitor each SSSC loaded with fuel at the ISFSI,                                                                                    .
APPLICABILITY:      When one or more SSSC loaded with fuel are at the ISFSt.
ACTIONS CONDITION                            REQUIRED ACTION                                                              COMPLETION TIME
  .                    A. LC0 not met                A.1            Check and repair the                                                        48 hours
                                                                        .;ystem.                                                                                                    .
g3 A2              !nstall a teaporary                                                        48 hours                        <
pressure monitoring 2
alarm panel.                                                                                                ,
9 1
[
4
                                                                                                                                                                                      ?
North Anna ISFSI                                3.1 9                                                                        Amendment No.
9- P        --          *>  %'    -3 H-    e- r %-y- :n r -r      ,-er'iH-y    -- 4 -e -------et+-y-w-w-e--aa,T=--g--g-----,----yem,,wrv                    - w-m-- ee-w
_ __ -    _ . _ . _ _        -                      ~
,.    ., 3
    ~
SSSC Pressure Monitoring System 3.1.5 ACTIONS (continued)
SURVEILLANCE REQUIREMENTS SURVEILLANCE                              FRE0VENCY SR 3.1.5.1      Verify that the SSSC is being monitored by      Within 48 hours the SSSC pressure monitoring system.            of arrival of a loaded SSSC at the ISFSI SR 3.1.5.2      Verify that the SSSC pressure monitoring        365 days system is operable and is monitoring each SSSC loaded with spent fuel at the ISFSI.
North Ann'a ISFS1                          3.1-10                Amend 7ent No.
 
SSSC Pressure Monitoring System 3.1.5 febte 3.1 1 isst Depeneeni atte.ebte value.
SilC n0 DEL                                                    Alt 0WABLE VALUt
: 1. TN 32
: e. Veccan Proesure
* 3 sher held
                                                                                    ~f or 10 sf rwtes
: b. Mellus teckfitt Pressure                                        2230 sher
* 100 sher
: c. MellunLeek Rete                                          g 1.0 N 10~' aber titer /sec i
: d. Olssolved Beren Concentration                                              1 2000 pgse
: e. 355C side everste surface dose rete                            3129 eres/ hove (neutren end penne)
: f. lllC top eversee surfece dose rate                              1 ji mrom/ hour                                    ]
(neutron and penne) 3 removable enterior surfece conteelnetton                        31000 dpv100 co' (bete end pensne) l AND 3 20 epV100 cm; (alphe)                                  ;
: h. Mealgun Lifting Helpht                                        3 elphteen inches North Anna ISFSI                                      3.1-11                                    Amendment No.
 
    ,. e, Dissolved Boron Concentration 3.2.1 3.2        SSSC CRITICALITY CONTROL 3.2.1      Dissolved Boron Concentration LC0 3.2              The dissolved boron concentration of the water in the spent fuel pool and of the water added to the cavity of a loaded SSSC shall be within limits specified in Table 3.1 1.
APPLICABILITY:      All SSSC loading operations.
All SSSC unloading operations ACTIONS CONDITION                          REQUIRED ACTION                COMPLETION TIME A. Dissolved boron            A.        Suspend SSSC fuel loading          Immediately concentration limit                  operations not met during SSSC loading operation.
B. Dissolved boror.            B.        Suspend SSSC fuel                  Imediately concnetration liniit                  unloading operations not met during unloading operation.
l North Anna ISFSI                              3.2 1                          Amendment No.
 
e ; +-
Dissolved Boron Concentration
                        +
3.2.1-SURVEILLANCE RE00:REMENTS SURVEILLANCE                              FRE0VENCY SR-3.2.1-    -Verify dissolved boron concentration limit        Within 4 hours in. spent fuel pool water is met,              prior to -
inserting first fuel assembly into SSSC during loading operations 48 hours-thereafter while SSSC loading is in progress SR 3.2.2          Verify dissolved ~ boron concentration limit  Within 4 hours in spent fuel pool water is met,              prior to flooding SSSC during SSSC unloading operations M
48 hours thereafter while SSSC unloading is in progress M
North Annc ISFSI-                        3.2-2                  Amendment No.
J
 
s ,-*~
l
>-                                                                                                                            SSSC Average Surface Dose Rate 3.3.1 3.3          SSSC RADIATION PROTECTION 3.3.1 SSSC Average Surface Dose Rates LCO '3.3.1                            The average dose rates (neutron + gamma) on the side and top surfaces of each SSSC shall meet the' limits specified in Table 3.1-1 APPLICABILITY:                          All SSSC loading operations ACTIONS                                                                                                                                _
CONDITION                    REQUIRED ACTION                                                  COMPLETION TIME A. SSSC average surface                            A.1    Discontinue further                                            Immediately dose rate limit not                                      loading activity met A.2      Verify correct fuel                                          24 hours loading M
A.3.1      Perform analysis to                                        48 hours demonstrate compliance with radiation protection requirements of 10 CFR Part 20 and 10 CFR Part 72 08 A.3.2      Return SSSC t'o spent                                      7 days fuel pool and unlcud
                                                                            -spent fuel back into pool
  ?
D' North Anna ISFSI                                          3.3-1                                                            Amendment No.
 
SSSC Average Surface Dose Rate 3.3,1
                . SURVE1LLANCE RE0VIREMENTS SURVEli. LANCE-                                  FRE0VENCY SR 3.3,1.-1    Verify that the SSSC surface dose rates do -          Once during-not exceed the specified limits.                      SSSC Inading operations l
4 4
North Anna ISFSI                                  3.3-2              Amendment No.
 
SSSC Surface Contamination 3.3.2 3.3      SSSC RADIATION PROTECTION 3.3.2 SSSC Surface Contamination LC0 3.3.2          Removable contamination on the SSSC exterior surfaces shall be within the limits specified in Table 3.11.
APPLICABILITY:    All SSSC loading operations ACTIONS                                                    _
CONDITION                  REQUIRED ACTION          COMPLETION TlhE A. SSSC removable surface    A.1    Discontinue activity    Immediately cont 3mination limit              to move SSSC to ISFSI not met AND A.2    Perform                As soon as decontamination        practical measures as necessary to meet limit.
f d
North Anna ISFSI                      3.3-3                  Amendment No.
 
SSSC Surfece Contamination 3.3.2
    ~
SURVEILLANCE REQUIREMENTS SURVEILLANCE                                                                      FREQUENCY SR 3.3.2.1      Verify that the removale contamination on                                                                    Once during the SSSC exterior surfaces does not exceed                                                                  SSSC loading the spe:ified limits,                                                                                        operations V
North Anna ISFSI                                                      3.3-4                                                Amendment No.
 
ISFSI Perimeter Radiation Levels 3.3.3  .
3.3    SSSC RADIATION PROTECTION 3.3.3 ISFSI Perimeter Radiation Levels LCO 3.3.3          The ISFSI's contribution to the radiation doses (neutron +gama) at the ISFSI perimeter fence shall not exceed the limits provided in Figure 3.3-1.
APPLICABILITY:      When one or more SSSCs loaded with spent fuel are at the ISFSI.
ACTIONS CONDITION                                      REQUIRED ACTION            COMPLETION TIME A. Radiation 3rotection              A.1                Perform analyis to      48 hours limits of Ngure 3.3-1                                demonstrate are not mct.                                          compliance with limits of 10 CFR Part 20 and 10 CFR Part 72.
QB A.2                Take action necessary    As.soon as to restore radiation      practical levels to within limits.
North Anna ISFSI                                          3.3-5                      Amendment No.
 
  ..,,e..
l                                                                                                                                              ISF.'I Perimc;.'r Radiation Levels l                                                                                                                                                                          3.3.3 SURVEILLANCE RE0VIREMENTS SURVEILLANCE                                                                                                        FREQUENCY SR 3.3.1.1      Verify that the ISFSI's contribution to the                                                                                          92 days radiation doses (neutron +gma) at the ISFSI perimeter fence do not exceed the specified limits.                                                                                                                                    ,
4 North Anna ISFSI                                                            3.3-5                                                                  Amendment No.
 
SSSC DEGRADATICN I                                                                                                                                                                                                                3.4
                                                      ~
3.4 SSSC Degradation LC0 3.4                              The accessible surfaces of each SSSC shall be free of damage, deterioration, and debris.
APPLICABILITY: When one or more SSSCs loaded with spent fuel are at tne ISFSI.                          3
                                                                                                            $TIONS CONDITION                                      REQUIRED ACTION            COMPLETION TIME A. LC0 not met.                                    A.1    Take appropriate          As soon as corrective action        practical 3
t North Anna ISFSI                                            3.4-1                    Amendment No.
 
  . . o c.
SSSC DEGRADATION 3.4
                      -.SURVElLLANCE-REQUIREMENTS SURVEILLANCE '                        FREQUENCY SR 3.4.1.1    Verify that no significant damage or        92 days deterioration of the exterior of the SSSC has occurred, and that no significant accumulation of debris on SSSC surfaces has occurred.
i North Anna ISFSI                      3.4-2                Amendment No.
 
vi o e-Design Features 4.0 4.0 DESIGN FEATURES 4.1 Site 4.1.1 Site and Exclusien Area Boundaries The North Anna site boundaries shall be as shown in Figure 4.1-1.
4.1.2 Storace Pad The North Anna ISFSI storage pads are reinforced concrete, with nominal dimensions of 224 feet x 32 feet x 2 feet thick with a 40-foot ramp on each end for vehicle access. Each pad is designed to store 28 SSSCs arranged in two rows. The SSSCs in each row will be spaced 16 feet apart center to center. Each row of SSSCs will be spaced 16 feet apart center to center. The facility will have three storage pads, if required. Figure 3/4-1 provides a sketch of the Notth Anna ISFSI.
4.2 Storage Features 4.2.1                        11.praaeCask The North Anna ISFSI is currently licensed to store spent fuel in the TN-32 dry storage cesk.
4.2.2                        116raaeCaoacity The total storage capacity of the North Anna ISFSI is limited to 839.04 metric tons uranium.
North Anna ISFSI                                      4.0-1                          Amendment No.
 
coe J                                                                                                            Administrative Controls 5.0 5.0 ADMINISTRATIVE CONTROLS 5.1 General The North Anna ISFSI is located on the North Anna Power Station site and will be managed and operated by the Virginia Power staff.
The administrative controls regarding responsibilities, organization. Staff Qualification. Procedures. Programs, and Reporting Requiremer.ts shall be in accordance with the requirements of the North Anna Power Station Operating Licenses (NPF-4 and NPF-7) and associated Technical Specifications, as appropriate. except as specifically modified below.
5.2 Reporting Requirements 5.2.1                    Environmental Monitorina Proaram Virginia Power shall include the North Anna ISFSI in the environmental monitoring program for the North Anna Power Station.
An environmental monitoring program is required pursuant to 10 CFR 72.44(d)(2). Virginia Power shall include the ISFSI in the Environmental Operating Report for the North Anna Power Station, and a copy shall be sr 't by May 1 of each year to the Director.
Office of Nuclear Matt. tal Safety end Safeguards.
5.2.3                      Annual Radioactive Effluent Release Reoort                                                                                      .
An annual report, as required by 10 CFR 50.36a(a)(2), which is the North Anna Power Station Annual Radioactive Effluent Release Report, shall include the North Anna ISFSI and shall be submitted by May 1 of each year to the NRC Region 11 Office, with a copy to the Director. Office of Nuclear Material Safety and Safeguards.
This report shall specify the quantity of each of the principle radionuclides released to the environment in liquid and gaseous effluents during the previous year of operation and such other information as may be required by the Commission to estimate maximum potential radiation dose commitment to the public resulting from effluent release. The report under this specification is also recuired pursuant to 10 CFR 72.44(d)(3)
(with an exemption regarcing the requirement to submit the report within 60 days ofter January 1 of each year).                                                                                      ;
North Anna ISFS1                                                              5.0-1                                  Amendment No.                            .
{
l                                  .
                                                                                ._ _                      _                          _                    --_}}

Revision as of 06:39, 1 January 2021

Forwards Draft Reformatted Proposed North Anna ISFSI TS, According to Improved Std TS Format,For Review.Comments & Addl Proposed Changes Requested by 980130
ML20203A841
Person / Time
Site: North Anna  Dominion icon.png
Issue date: 12/04/1997
From: James Shea
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Ohanlon J
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
References
TAC-L22113, NUDOCS 9712120235
Download: ML20203A841 (44)


Text

_ _ _

tl s, December 4, 1997

' c-s

. Mr. James P. O'Hanlon Senior Vice Presidut Nuclear c - Virginia Electric ar*.d Power Company Innsbrook Technical Center -

5000 Dominicn Boulevard Glen Allen, VA 23060

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION (RAI) CONCERNING THE APPLICATION FOR THE NORTH ANNA INDEPENDENT SPENT FUEL ,

STORAGE INSTALLATION (TAC NO. L22113)

Dear Mr. O'Hanlon:

- By letter dated May 9,1995, you submitted an application to the Nuclear Regulatory '

Commission in accordance with 10 CFR Part 72 for the review and approval of a siteispecific  ;

license for an independent spent fuel storage installation (ISFSI) at the North Anna Nuclear Power Station site. Your application included proposed technical specifications (TS) for the North Anna ISFSI.

- - The staff continues to review your proposed TS and is considering an initiative to modify ISFSI . '

' TS to be consistent with the form and content of the improved Standard Technical

, Specifications (ITS) for operating reactors. As part of this initiative, the staff has reformatted f Virginia Power's proposed North Anna ISFSI TS according to the ITS format. A copy of the ~ '

, staff's draft reformatted North Anna ISFSI TS is enclosed.

, The staff is continuing an aggressive internal review of the reformatted TS, drawing on staff ,

experience gained with the operating reactor ITS program. The staff requests that you review

> the enclosed reformatted TS and provide comments and proposed changes regarding both form .

and content by January 30,1998, in addition, please prepare appropriate TS bases using the depth of detail and format of the ITS bases as a guide.

If you have any comment or question concerning this request, please contact me at 301-415-1309.

Sincerely,

[ original signed by /s/j Joseph W. Shea, Project Manager Spent Fuel Licensing Section Spent Fuel Project Office Office of Nuclear Material Safety g and Safeguards gg q Docket No. 72-16 (50-338/339) i

Enclosure:

Draft Reformatted North Anna ISFSI TS g[I cc: Service List Destnbution. (Control No. 010S)

Docket ~ NRC File Center PUBLIC .__ NMSS r/f SFPO r/f SFLS r/f CHaughney SShankman WReamer.OGC KCleu <

EKeegan - SO' Conner NKa!yanam NRR WGloerson, Ril /

OFC SFPO b SFPOY b SFPO 6- SFPO -

NAME JSheahbfh rpe FSturz r,vr*1 N EJLeeds 8

-DATE 11/2bh 114b/97 ,t JI /97 MJ3 C = COVER E = COVER & ENCLOSURE N = NO COPY OFFICIAL RECORD COPY GSNORTH_AN\L22113.RA3 9712120235 971204 1 l Igl 'I l llll J PDR ADOCK 05000338 .a a]

ll1 ]l..lul. jl v _en .lhl.-l .

__ _ -_ , _. - . _ _ _ _ - ___ _ _ .~_____ _ ._

3; .A '

Mr..J.PI0'Hanlon -

North Anna Power Station

- Virginia Electric & Power Company. Units 1 and 2 CC;'

Mr. William C. Porter. Jr. Regional Administrator.. Region 11-County Administrator U.S. Nuclear Regulatory Commission Louisa County Atlanta Federal Cer.ter P.O. Box 160 61 Forsyth-St. SW. Suite 23T85 Louisa. Virginia 23093 Atlanta.-Georgia 30303 3415 Michael W. Maupin Esquire Mr. W. R. Mdtthews, Manager

. Hunton and Williams North Anna Power Station

- Riverfront Plaza. East. Tower P. 0. Box 402 951 E. Byrd Street Mineral. Virginia 23117 Richmond, Virginia 23219.

Mr. Al Belisle ..

Dr. W. T. Lough U.S. Nuclear Regulatory Comission

Virginia State Corporation Atlanta Federal Center Commission 61 Forsyth St., SW. Suite 23T85 Division of Energy Regulation Atlanta. Georgia 30303 3415 P. O. Box 1197 Richmond, Virginia 23209 Mr. David Christian Manager Surry Power Station Old Dominion Electric Cooperative Virginia Electric and Power Company 4201. Dominion Blvd. 5570 Hog Island Road

. Glen Allen. Virginia 23060 Surry, Virginia 23883 Mr. James H. McCarthy. Manager Mr. J. P. O'Hanicn Nuclear Licensing & Operations Senior Vice President - Nuclear Support Virginia Electric and Power Company Virginia Electric and Power Company Innsbrook Technical Center Innsbrook Technical Center 5000 Dominion Blvd.

5000 Dominion Blvd. Glen Allen. Virginia 23060 Glen Allen. Virginia 23060 Office of the Attorney General Commonwealth of Virginia

, 900 East Main Street Richmond Virginia 23219 i

Senior Resident Inspector North Anna Power Station U.S. Nuclear Regulatory Comission 1024 Haley Drive Mineral. Virginia -23117 2 . Robert.B. Strobe M.D.. M.P.H.

. State Health Commissioner Office of the Commissioner Virginia Department of Health P.O. Box 2448 Richmond, Virginia 23218 d

ym ei. w. y - --pid- y y - a Ir' - D- e - w - I eE

9 g Draft Reformatted North Anna ISFSI TS Enclosure

4 .4  !

. Definitions i

. 1.1  !

1,0 USE AND. APPLICATION 1,1 Definitions

.................................... NOTE---------------- --------------------

The defined terms of this section ap ear in capitalized t pe and are applicable throughout these Technica Specifications and ases.

Term Definition ACTIONS ACTIONS shall be that part of a Specification that prescribes Required Actions to be taken under designated Conditions within specified Completion Times.

LOADING OPERATION Loading operations include all SSSC preparation steps before SSSC transport from the-Decontamination Building.

OPERABLE-OPERABILITY A system, subsystem. division, com>onent, or device shall be OPERABLE or have 0)ERABILITY when it is capable of aerforming its specified safety function (s) and w1en all necessary attendant instrumentation, controls, normal or emergency electrical power, cooling and seal water, lubrication, and other auxiliary equipment that are required for the system, subsystem, division, component, or device to perform its specified safety function (s) are also capable of performing their related support function (s).

i North Anna ISFSI 1.1-1 Amendment No.

l

. . Logical Connectors

  • - . 1,2 1.0 USE AND APPLICATION 1.2 Logical Connectors 4

PURPOSE The purpose of this section is to explain the meaning of logical connectors.

, Logical connectors are used in Technical Specifications (TS) to discriminate between, and yet connect, discrete Conditions, Re Surveillances,and quired Actions. Completion Times,The only logical c Frequencies.

that appear in TS are BlQ and 2. The physical arrangement of these connectors constitutes -logical conventions with specific meanings.

BACKGROUND Several levels of logic may be used to state Required Actions. These levels are identified by the placement (or nesting) of the logical connectors and by the number assigned to each Required Action. The first level of logic is identified by the first digit of the number assigned to a Required Action and the placement of the . logical connector in the first level of nesting (i.e., left justified with the number of the Required Action). The successive levels of logic are identified by additional digits of the Required Action number and by successive indentions of the logical connectors.

When logical connectors are used to state a Condition.

Completion Time, Surveillance, or Frequency, only the first level of logic is used, and the logical connector is left justified with the statement of the Condition, Completion Time, Surveillance, or Frequency.

EXAMPLES The following examples illustrate the use of logical connectors.

, (continued)

North-Anna ISFSI 1,2-1 Amendment No.

- n .

s-.. n ..-~ ..x - . , - - _n - ,. - . . . - - . . ~ . - _ .~-a.. . - - - -

<, s,

^

Logical Connectors 1.2 1.2 Logical Connectors EXAMPLES EXAMPLE 1.2-1 (continued)

ACTIONS CONDITION REQUIRED ACTION COMPLETION TlHE A. LCO not met. A.1 Verify . . .

68D A.2 Restore . . .

I __.

In this example the logical connector LN) is used to indicate that when in Condition A, both Required Actions A.1 and A.2 must be completed.

. (continued)

North Anna ISFSI 1.2 2 Amendment No.

. Logical Connectors 1.2 1.2 Log $ a' Connectors EXAMPLES EXAMPLE 1 2-2 (continued)

ACTIONS CONDITION REQUIRED ACTION COMPLETION TiliE A. LCO not met. A.1 Trip . . .

A.2.1 Verify . . .

RfD A.2 2.1 Reduce . . .

A.2.2.2 Perform . . .

A.3 Align . . .

This example represents a more complicated use of logical connectors. Required Actions A.I. A.2 and A.3 are alternative choices only one of which must be performed as indiccted by the use of the logical connector @ and the leftjustified Any one of these three Actions may be chosen.If placement. A.2 is chosen then both A.2.1 and A.2.2 must be performed as indicated by the logical connector MiQ.

Required Action A.2.2 is met by performing A.2.2.1 or A.2.2.2, The indented position of the logica: connector

@ indicates that A.2.2.1 and A.2.2.2 are alternative choices, only one of which must be performed.

North Anna ISFSI 1.2 3 Amendment No.

, -y .-a., e .w,-=,we-gg -- , + - - - .es---y+- v- -*-r,

y *,

- . Completion Times -

. 13  ;

1.0 USE AND APPLICATION  !

1.3 Completion Times f

I

' PURPOSE The purpose of this section is to establish the Completion Time convention and to provide guidance for its use.  :

BACKGROUND LimitingConditionsforOperation(LCOs)specifyminimum.  :

requirements for er.suringaafe operation of the unit. The ACTIONS associated with an LC0 state Conditions that typically describe the ways in which the requirements of the .

LCO can fail to be met. Specified with each stated Condition are Required Action (s) and Completion Times (s).

DESCRIPTION The Completion Time is the amount of time allowed for completing a Required Action. It is referenced to the time <

of discovery of a situatun (e.g., inoperable equipment or  !

variable not within limits) that requires entering an '

ACTIONS Condition unless otherwise specified, providing the unit is in a specified condition stated in the Applicability of the LCO. Required Actions must be completed prior to the expiration of the specified Completion Time. An ACTIONS Condition remains in effect and the Required Actions apply until the Condition no longer exists or the unit is not

-within the 100 Applicability. ,

Once a Condition has been entered subsequent divisions.

Subsystems. components, or variables expressed in the Condition, discovered to be inoperable or not within limits.

will ng1 result in separate entry into the Condition unless .

specifically stated. The Recuired Actions of the Condition continue to apply to each adcitional failure, with Completion Times based on initial entry into the Condition.

(continued) i 4

I 4 North Anna ISFSI 1.3 1 Amerdment No. .

, - , , . . , , , , . - , . , . ,- ,. . , , - - . , - . . , . , , , , , . , . - . . , . - , . , . . . - , , - - - . , , ,,..,,,,nn,.,,.,-,.,.,na,. . . ,

9 t 4

Completion Times f 1.3 I

1.3 Completion Times DESCRIPTION However, when a subseauent division, subsystem, component.

(continued) or variable expre.ssed in the Condition is discovered to be inoperable or not within limits, the Completion. Time (s) may be extended. To apply this Completion Time extension. two criteria must first be met. The subsequent inoperability:

a. Must exist concurrent with the ,tjrit inoperability:

, and

b. Must remain inoperable or not within limits after the first inoperability is resolved.

The total Completion Time allowed for completing a Required Action to address the subsequent inoperability shall be y

limited to the more restrictive of either:

. a. The stated Completion Time. as measured from the initial entry into the Condition, plus an additional i

24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />s
or
b. The stated Completion Time as measured from discovery of the subsequent inoperability.

The above Completion Time extension does not ap)1y to a Completion Time with a modified " time zero." T11s modified

" time zero" may be ex)ressed as a repetitive time (1-.e..

"once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />." w1ere the Completion Time is referenced from a previous completion of the Required Action versus the time "fromofdiscovery Condition . .entry)

." Example 1.3 3 illustrates one use ofor a this type of Completion Time. The 10 day Completion Time specified for Condition A and B in Examp!e 1.3 3 may not be extended.

(continued) i North Anna ISFSI 1.3 2 Amendment No.

0 w y ,-- .m., . , , - - ,,,m.- - w..-_ , ,- .--r, _ , - . , .~,,-,-,-m.,,.%-.

9 '<

Completion Times 1.3 I

1.3 Completion Times (continued) l l

EXAMh.ES The following examples illustrate the use of Completion Times with different types cf Conditions and changing  ;

Conditions.

EXAMPLE 1 3 1 ACTIONS CONDITION Rf.0VIRED ACTION COMPLETION TIME B. Required B.1 Perform Action 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Action and B.1 associated Completion M Time not met. B.2 Perform Action 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> B.2 Condition B has two Required Actions. Each Required Action has its own separate Completion Time. Each Completion Time is referenced to the time that Condition B is entered.

The Required Actions of Condition B are to be complete action B.1 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> @ complete action B.2 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. A total of 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> is allowed for com action B.1 and a total of 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> (not 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />)pleti.10is allowed for completing action B.2 from the time that Condition B was entered. If action B.1 is completed within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> the time allowed for completing action B.2 is the next 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br /> because the total time allowed for completing action B.2 is 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />.

.. (continued)

North Anna ISFSI 1.3 3 Amendment No.

Completion Times

. 1.3 1.3 Completion Times EXAMPLES EXAMPLE 1.3 2 (continued)

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. One system A.1 Restore system to 7 days inoperable. OPERABLE status.

B. Required B.1 Complete action 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Action and B.1 associated Completion Aj@

Time not 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> met. B.2 Complete action B.2 When a system is declared inoperable, Condition A is entered. If the system is not restored to OPERABLE status within 7 days. Condition B is also entered and the Completion Time clocks for Required Actions B.1 and B.2 start. If the inoperable system is restored to OPERABLE status after Condition B is entered. Condition A and B are exited, and therefore, the Required Actions of Condition B may be terminated.

North Anna ISFSI 1.3 4 Amendment No.

l

I s

Frequency 1.4 1.0 USE AND APPLICATION 1.4 Frequency I PURPOSE The purpose of this section is to define the proper use and application of Frequency requirements.

DESCRIPTION Each Surveillance Requirement (SR) has a specified frequency in which the Surveillance must be met in order to meet the 1

associated Limiting Condition for Operation (LCO). An understanding of the correct application of the specified frequency is necessary for compliance with the SR. . ,

The "specified Frequency" is referred to throughout this section and each of the Specifications of Section 3.0.

Surveillance Requirement (SR) Applicability. The "specified Frequency" consists of the requirements of the Frequency  ;

column of each SR, as well as certain Notes in the  :
Surveillance column that modify performance requirements.

Sometimes special situations dictate when the requirements of a Surveillance are to be met. They are "otherwise stated" conditions allowed by SR 3.0.1. They may be stated as clarifying Notes in the Surveillance, as part of the Surveillance, or both. Example 1.4-4 discusses these

special situations.

Situations where a Surveillance could be required (i.e., its Frequency coula expire), but where it is not possible or not desired that it be performed until sometime after the associated LCO is within its Applicability, represent potential SR 3.0.4 conflicts. To avoid these conflicts, the SR (i.e., the Surveillance or the Frequency) is stated such that it is only " required" when it can be and should be performed. With an SR sotisfied. SR 3.0.4 imposes no restriction.

The use of " met" or " performed" in these instances conveys specific meanings. A Surveillance is " met" only when the acceptance criteria are satisfied. Known failure of the

. requirements of a Surveillance, even without a Surveillance specifically"being " performed." constitutes a Surveillance not " met." Performance" refers only to the requirement to specifica'ly determine the ability to meet the acceptance

- (continued)

North Anna 1.4 1 Amendment No.

n'*

v o Frequency 1.4 1.4 Frequency DESCRI." TION criteria. SR 3.0.4 restrictions would not apply if both the (continued) following conditior.s are satisfied:

a. The Surveillance is not required to be performed; and
b. The Surveillance is not required to be met or, even if required to be met is not known to be failed.

EXAMPLES The following examples illustrate the various ways that Frequencies are specified.

EXAMPLEiJ.:.'.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY ,

Perform CHANNEL CHECK. 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Example 1.4 1 contains the type of SR most often encountered in the Technical Specifications (TS). The Frequency specifies an interval (12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />) during which the associated Surveillance must be performed at least one time.

Performance of the Surveillance initiates the subsequent interval. Although the Frequency is stated as 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, an extension of the time interval to 1.25 times the interval specified in the frequency is allowed by SR 3.0.2 for operational flexibility. The measurement of this interval continues at all times, even when the SR is not required to be met aer SR 3.0.1 (such as when the equipment is inoperaale, a variable is outside specified limits, or the unit is outside the Applicability of the LCO). If the interval specified by SR 3.0.2 is exceeded while the unit is in a condition specified in the Applicability of vne LCO.

and the performance of the Surveillance is not otherwise modified (refer to Examples 1.4 3 and 1.4 4), then SR 3.0.3 becomes applicable.

(continued)

North Anna 1.4-2 Amendment No.

Frequency 1.4 1.4 Frequency EXAMPLES' EXAMPLE 1 4 1 (continued)

If the interval as specified by SR 3.0.2 is exceeded while the unit is not in a condition specified in the Applicability of the LCO for which performance of the SR is required, the Surveillance must be performed within the Frequency requirements of SR 3.0.2 prior to entry into the specified condition. Failure to do so would result in a violation of SR 3.0.4.

EXAMPLE 1.4-2 SURVEILLANCE REOUIREMENTS SURVEILLANCE FRE0VENCY Verify flow is within limits. Once within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> prior to starting activtity M

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter Example 1.4-2 has two Frecuencies. The first is a one time performance Frequency, anc the second is of the type showT) in Example 1.4 1. The logical connector "E" indicates that both Frequency requirements must be met. Each time the example activity is to be performed, the Surveillance must be performed within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> prior to starting the activity.

The use of "once" indicates a single performance will satisfy the specified Frequency (assuming no other Frequencies ~are connected by " E "). This t pe of Frequency does not qualify for the extension allowed b SR 3.0.2.

(continued) f North Anna 1.4-3 Amendment No.

I Frequency 1.4 1.4 Frequency EXAMPLES EXAMPLE 1.4 2 (continued)

"Thereafter" indicates future performances must be established per SR 3.0.2. but only after a specified condition is first met (i.e., the "once" performance in this example). If the specified activity is cancelled or not performed, the measurement of both intervals stops. New intervals start upon preparing to restart the specified activity, i

North Anna 1.4-4 Amendment No.

- . . SLs 2.0 2.0 SAFETY LlHITS (SLs) i 2,1 SLs  !

- 2.1.1 Fuel To 3e Stored At The ISFSI l The spent nuclear fuel to be stored in SSSCs at the North Anna ISFSI shall meet the following requirements:

(1) Only fuel assemblies irradiated at the North Anna Power Station Units 1 and 2 may be stored.

(2) Fuel assemblies shall be intact. Partial fuel assemblies, that i is, fuel assemblies from which fuel rods are missing must not be loaded in SSSCs unless dummy fuel rods are used to displace an-amount of water equal to that displaced by the original fuel rods.

(3) Fuel assemblies known or suspected to have structural defects or gross cladding failures sufficiently severe to adversely affect i fuel handling and transfer capability shall not be loaded into  !

SSSCs for storage.

(4) Fuel assemblies shall meet the limits for initial enrichment.

average burnup, deca heat, and cooling time after reactor j discharge as specifi d in Table 2.11 4

i 1

NORTH ANNA ISFSI 2.0 1 Amendment No.

t

,yvew av,- y ,.- g--t-iy-~ ,ywe yqsiy,iy-q.-'-y e

.g er g w p.e--& r-M i s. e w v1mme Ve pw V ww h,w.+em1m-w---s-i =e,ei-ds-c- .=-ms'-i-- * *w+ rs - #v'-

SLs 2.0  ;

i J

2.2 SL Violations With any SL violation. the following actions shall be completed:

2.2.1 Within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, notify the NRC Operations Center.

2.2.2 Within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, notify the Plant Manager and the Vice President-Nuclear Engineering.

f 2.2.3 Within 30 days, a written report, similar to a Licensee Event Report (LER) in 10 CFR 50.73, shall be prepared and submitted to the NRC.

2.2.4 Continued loading of SSSCs shall not be resamed until authorized by the NRC.

s NORTH ANNA ISFSI 2.0 2 Amendment No, d

i

.e,, ,. .. .- e-e-., w %-, ,eween -owassrmy--e n . _ ._r--w -

me =mawwwe,,,w,--. .<,-n. --~._en,-7 o . . _ . = , . . . _

y S

. SLs 2.0 febte 2.1 1 Fuel Assembly Characteristics

$55C N@EL ALLOWABLE VALUE

1. TN 32
e. Inittel Enrichment g 3.05 wt. I
b. Averece herup 3 0,000 4 thC/MTU
c. Cooline fime Af ter g 7 yeare Discherpo
d. Decay koet 3 0.N 3 km/sonesbly
e. TN Peremeter/ Power 700 Density NORTH ANNA ]SFSI 2.0 3 Amendment No. ,

v-* --__________ _. _ _ _ . _ _ -a _ , _ _ _. - , _ - _._6 -4 -rm e + , w w- e ewm, eseeve -nu , -y e wzewe~,e-- wes. --+e-+ -

LCO-Applicability- l 3.0 3.0 LIMITING CONDITION FOR OPERATION (LCO) APPLICABILITY J

LCO 3.0.1- LCOs shall be met during specified conditions in the i

Ap)licability, except as provided in LCO 3.0.2 and LC0 3.0.7. ,

LCO 3.0.2 0 on discover A!tionsofth of aassociated failure to Conditions meet an LCO.

shall the Required be met. except' as provided in LC0 3.0.5 and LC0 3.0.6, If the LCO is met or is no longer applicable prior to expiration of the specified Completion Time (s), completion of the Required Action (s) is not required, unless otherwise stated.

LC0 3.0.3 Deleted for ISFSI 15 LC0 3.0.4 When an LC0 is not met, entry into a specified condition in 4

the Applicability shall not be made except when the ,

associated ACTIONS to be entered permit continued operation
in the specified condition in the Applicability for an
unlimited period of time. This Specification shall not prevent changes in specified conditions in the Applicability that are required to comply with ACTIONS.

l LC0 3.0.5 Equipment removed from service or declared inoperable to i

comply with ACTIONS may be returned to service under

, administrative control solely to perform testing required to

- demonstrate its' OPERABILITY or the OPERABILITY of other equipment. This is an exception to LC0 3.0,2 for the system returned to service'under administrative control to perform the testing required to demonstrate OPERAPILITY.

-LC0 3.0.6 Deleted for ISFSI TS

..LC0 3.0.7 Deleted for ISFSI North Anna ISFSI 2;01 Amendment'No.

.., ,.,=.,.._p n, _ _

O SR Applicabilit 3.0 3.0 SURVEILLANCE REOUIREMENT (SR) APPLICABILITY SR 3.0.1 SRs shall be met during the s>ecified conditions in the Applicability for individual .COs, unless otherwise stated i in the SR. Failure to meet a Surveillance, whether such failure is ~ experienced during the performance of the-Surveillance or between performances of the Surveillance, shall be failure to meet the LCO. Failure to perform a Surveillance within the specified Frequency shall be failure to meet the LCO except as provided in SR 3.0.3.

Surveillances do not have to be performed on inoperable equipment or variables outside specified limits. i l

SR- 3.0.2 The specified Frequency for each SR is met if the I Surveillance is performed within 1.25 times the interval specified in the frequency, as measured from the previous performance or as measured from the time a specified condition of the Frequency is met.

l For Frequencies specified as *once.* the above interval .

extension does not apply. If a Completion Time requires

>eriodic performance on a *once per . . ." basis, the above requency extension a  ;

initial performance. pplies to each performance after the Exceptions to this Specification are stated in the individual Specifications.  ;

SR 3.0.3 If it is discovered that a Surveillance was not performed within its specified Frequency, then compliance with the requirement to declare the LCO not met may be delayed, from the time of discovery, up to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or up to the limit of the'specified Frequency. whichever is less. This delay period is permitted to allow performance of the

, wrveillance.

If the Surveillance is not performed within the delay period, the LC0 must imediately be declared not met and the applicable Condition (s) must be entered.-

When the Surveillance is performed within the delay period

' and the Surveillance is not met, the LC0 must immediately be declared not met. and the applicable Condition (s) must be >

entered.

(continued)

North Anna'ISFSI 3.0 2 ..nendment' No.

. ._ =: a. .=, -_,

, ..~..__7 _ _ ___ .-__ _

j

g. ., i SR Applicability  !

3.0

. 1 3.0 SR APPLICABILITY (contin td)

SR 3.0.4 Entry into a s>ecified condition in the Applicability of an .

LCO shall not >e made unless the LCO's Surve111ances have been met within their specified frequency. This provision ,

shall not prevent entry into specified conditions in the Applicability that are required to comply with ACTIONS. '

i I

i i

1 L

t 1

i o

l North Anna ISFSI 3.0 3 Amendment No.

._ _ . ._. _ .. m . . - - _ - .

. _ _ _ ~ _ _ . _ . . _ . _ . _ _ . _ _ . . . - _ -

. SSSC Vaccuum Pressure 3.1.1 3.1 SSSC CONFINEMENT INTEGRITY 3.1.1 SSSC Vaccuum Pressure LC0 3.1.1 The SSSC cavity vacuum pressure shall meet the limit specified in Table 3.11 for the applicable SSSC design.

APPLICABILITY; All SSSC loading operations ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. SSSC cavity vaccuum A.1 Discontinue further immediately pressure limit not met loading activity bhD A.2 Restore vaccum system As soon as or SSSC seal practical operability 2

A.3 Retirn SSSC to spent 7 days fue4 pool and unload

pent fuel back into pool North Anna ISFS1 3.1-1 Amendment No.

s, ..

SSSC Vaccuum Pressure 3.1.1 SURVEILLANCE REQUIREMENTS SURVEILLANCE FRE0VENCY SR 3.1.1.1 Verify that the SSSC cavity vacuum pressure Once during meets the specified limit. SSSC loading operations 4

I I

North Anna ISFS! 3.1 2 Amendment No.

+,

9 ,

, SSSC Helium Backfill 3.1.2 3.1- SSSC CONFINEMENT INTEGRITY l

3.1.2 SSSC Helium Backfill Pressure l l

LC0 3.1.2 The SSSC cavity vacuum pressure shall meet the limit- <

specified in Table 3.1-1-for the applicable SSSC design. l

, = APPLICABILITY: All SSSC loading operations j ACTIONS t CONDITION REQUIRED ACTION  : COMPLETION TIME A. SSSC helium backfill A.1 Discontinue further Imediately pressure limit not met loading activity

! OD I

A.2 Restors helium As soon as backfill pressure to practical within limits g ,

A.3 Return SSSC to spent 7 days '

fuel pool and unload spent fuel back into

pool
  • i 4

a t ,

i

(-

!ij l

North Anna ISFSI 3.1-3 Amendment No. ,

,n- - - . . , ,.y.g gw ,N,,--,,..---,e e_,,,,-e.,--,. - ----,,,,--,,,,,w,,----,--,-, .,,n--.n, . , , - ,-. ,-,,w-.. - - , , , , , , - - , , , , . , , , -

SSSC Helium Backfill 3.1.2  ;

. SURVEILLANCE RE0VIREMENTS I SURVEILLANCE FRE0VENCY f

SR 3.1.2.1 Verify that the SSSC helium backfill Once during  ;

pressure meets the specified limit. SSSC loading  ;

operations -

t f

i P

t 1

I I

i i

i I

4 i

i North Ania ISFSI 3.1 4- Amendment No.

. . . . -.. . - - . . . - - . . . . - - . . . - - - , - . , . , . - . . , . . . . - _ . - . . . - . - - _ _ - - . . . . ~ . , , . . . . _ . - _ . -

Helium Leakage 3.1.3  ;

3.1_ SSSC CONFINEMENT INTEGRITY l 3.1.3 Helium Leakage LC0 3.1.3 The total helium leak rate for all closure seals shall not exceed the limit specified in Table 3.1-1 for the applicable SSSC design. I APPLICABILITY: All SSSC loading operations.  !

ACTIONS i

CONDITION REQUIRED ALTlt. COMPLETION TIME A. SSSC helium leakage A.1 Discontinue further Immediate1) limits not met loading activity MD  :

A.2 Restore helium As soon as backfill pressure to practic61 within limits DB A.3 Return SSSC to spent 7 days fuel pool and unload  :

spent fuel back into i pool i

1 i

L North Anna ISFSI 3.1-5 Amendment No.  :

L _ _ . . ._ _ _ _ _ _ __ _ _ _._ ;.__ __ _ _

e **

Helium Leakage 3.1.3 SURVEILLANCE REQUIREMENTS  !

SURVEILLANCE FRE0VENCY SR 3.1.3.1 Verify that the SSSC helium leakage meets the specified limit. g n operations 1

I l

North Anna ISFSI 3.1-6 Amendment No.

.' SSSC Inter seal Pressure 3.1.4 3.1 SSSC CONFINEMENT INTEGRITY 3.1.4 SSSC INTER-SEAL PRESSURE LC0 3.1.4 The status indicators for each SSSC on the pressure monitoring alarm panel shall indicate satisfactory closure seal operation.

APPLICABILITY: Each SSSC loaded with fuel at the JSFSt.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Status indicator for A.1 Verify that the SSSC Imediately any loaded SSSC pressure monitoring indicates system is operable, unsatisfactory seal operation l@

A.2 If manitoring of the As soon as reference pressure practical between SSSC closure seals indicates a loss of 3ressure and seal leatage, return the SSSC to the Decentamination Building and repair or replace the seals, as necessary, to return the SSSC to proper operation. .

North Anna ISFSI 3.1-7 Amendment No.

gs *e SSSC Inter-seal Pressure 3.1.4 SURVElllANCE REOUIREMENTS SURVEILLANCE FREQUENCY SR 3.1.4.1 Verify that the alarm panel status 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> indicators for each SSSC indicate satisfactory closure seal operation.

North Anna ISFSI 3.1 8 Amendment No.

3-.,-.- -.-.

- - . . -. := - - - .-__ . . - . -.. _.. - - .

SSSC Pressure Monitoring System  !

3.1.5  !

3.1.5 -SSSC Pressure Monitoring System f LC0 3.1.5 The SSSC pressure monitoring system shall be operable and shall monitor each SSSC loaded with fuel at the ISFSI, .

APPLICABILITY: When one or more SSSC loaded with fuel are at the ISFSt.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME

. A. LC0 not met A.1 Check and repair the 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />

.;ystem. .

g3 A2 !nstall a teaporary 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> <

pressure monitoring 2

alarm panel. ,

9 1

[

4

?

North Anna ISFSI 3.1 9 Amendment No.

9- P -- *>  %' -3 H- e- r %-y- :n r -r ,-er'iH-y -- 4 -e -------et+-y-w-w-e--aa,T=--g--g-----,----yem,,wrv - w-m-- ee-w

_ __ - _ . _ . _ _ - ~

,. ., 3

~

SSSC Pressure Monitoring System 3.1.5 ACTIONS (continued)

SURVEILLANCE REQUIREMENTS SURVEILLANCE FRE0VENCY SR 3.1.5.1 Verify that the SSSC is being monitored by Within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> the SSSC pressure monitoring system. of arrival of a loaded SSSC at the ISFSI SR 3.1.5.2 Verify that the SSSC pressure monitoring 365 days system is operable and is monitoring each SSSC loaded with spent fuel at the ISFSI.

North Ann'a ISFS1 3.1-10 Amend 7ent No.

SSSC Pressure Monitoring System 3.1.5 febte 3.1 1 isst Depeneeni atte.ebte value.

SilC n0 DEL Alt 0WABLE VALUt

1. TN 32
e. Veccan Proesure
  • 3 sher held

~f or 10 sf rwtes

b. Mellus teckfitt Pressure 2230 sher
  • 100 sher
c. MellunLeek Rete g 1.0 N 10~' aber titer /sec i
d. Olssolved Beren Concentration 1 2000 pgse
e. 355C side everste surface dose rete 3129 eres/ hove (neutren end penne)
f. lllC top eversee surfece dose rate 1 ji mrom/ hour ]

(neutron and penne) 3 removable enterior surfece conteelnetton 31000 dpv100 co' (bete end pensne) l AND 3 20 epV100 cm; (alphe)  ;

h. Mealgun Lifting Helpht 3 elphteen inches North Anna ISFSI 3.1-11 Amendment No.

,. e, Dissolved Boron Concentration 3.2.1 3.2 SSSC CRITICALITY CONTROL 3.2.1 Dissolved Boron Concentration LC0 3.2 The dissolved boron concentration of the water in the spent fuel pool and of the water added to the cavity of a loaded SSSC shall be within limits specified in Table 3.1 1.

APPLICABILITY: All SSSC loading operations.

All SSSC unloading operations ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Dissolved boron A. Suspend SSSC fuel loading Immediately concentration limit operations not met during SSSC loading operation.

B. Dissolved boror. B. Suspend SSSC fuel Imediately concnetration liniit unloading operations not met during unloading operation.

l North Anna ISFSI 3.2 1 Amendment No.

e ; +-

Dissolved Boron Concentration

+

3.2.1-SURVEILLANCE RE00:REMENTS SURVEILLANCE FRE0VENCY SR-3.2.1- -Verify dissolved boron concentration limit Within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> in. spent fuel pool water is met, prior to -

inserting first fuel assembly into SSSC during loading operations 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />s-thereafter while SSSC loading is in progress SR 3.2.2 Verify dissolved ~ boron concentration limit Within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> in spent fuel pool water is met, prior to flooding SSSC during SSSC unloading operations M

48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> thereafter while SSSC unloading is in progress M

North Annc ISFSI- 3.2-2 Amendment No.

J

s ,-*~

l

>- SSSC Average Surface Dose Rate 3.3.1 3.3 SSSC RADIATION PROTECTION 3.3.1 SSSC Average Surface Dose Rates LCO '3.3.1 The average dose rates (neutron + gamma) on the side and top surfaces of each SSSC shall meet the' limits specified in Table 3.1-1 APPLICABILITY: All SSSC loading operations ACTIONS _

CONDITION REQUIRED ACTION COMPLETION TIME A. SSSC average surface A.1 Discontinue further Immediately dose rate limit not loading activity met A.2 Verify correct fuel 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> loading M

A.3.1 Perform analysis to 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> demonstrate compliance with radiation protection requirements of 10 CFR Part 20 and 10 CFR Part 72 08 A.3.2 Return SSSC t'o spent 7 days fuel pool and unlcud

-spent fuel back into pool

?

D' North Anna ISFSI 3.3-1 Amendment No.

SSSC Average Surface Dose Rate 3.3,1

. SURVE1LLANCE RE0VIREMENTS SURVEli. LANCE- FRE0VENCY SR 3.3,1.-1 Verify that the SSSC surface dose rates do - Once during-not exceed the specified limits. SSSC Inading operations l

4 4

North Anna ISFSI 3.3-2 Amendment No.

SSSC Surface Contamination 3.3.2 3.3 SSSC RADIATION PROTECTION 3.3.2 SSSC Surface Contamination LC0 3.3.2 Removable contamination on the SSSC exterior surfaces shall be within the limits specified in Table 3.11.

APPLICABILITY: All SSSC loading operations ACTIONS _

CONDITION REQUIRED ACTION COMPLETION TlhE A. SSSC removable surface A.1 Discontinue activity Immediately cont 3mination limit to move SSSC to ISFSI not met AND A.2 Perform As soon as decontamination practical measures as necessary to meet limit.

f d

North Anna ISFSI 3.3-3 Amendment No.

SSSC Surfece Contamination 3.3.2

~

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.3.2.1 Verify that the removale contamination on Once during the SSSC exterior surfaces does not exceed SSSC loading the spe:ified limits, operations V

North Anna ISFSI 3.3-4 Amendment No.

ISFSI Perimeter Radiation Levels 3.3.3 .

3.3 SSSC RADIATION PROTECTION 3.3.3 ISFSI Perimeter Radiation Levels LCO 3.3.3 The ISFSI's contribution to the radiation doses (neutron +gama) at the ISFSI perimeter fence shall not exceed the limits provided in Figure 3.3-1.

APPLICABILITY: When one or more SSSCs loaded with spent fuel are at the ISFSI.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Radiation 3rotection A.1 Perform analyis to 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> limits of Ngure 3.3-1 demonstrate are not mct. compliance with limits of 10 CFR Part 20 and 10 CFR Part 72.

QB A.2 Take action necessary As.soon as to restore radiation practical levels to within limits.

North Anna ISFSI 3.3-5 Amendment No.

..,,e..

l ISF.'I Perimc;.'r Radiation Levels l 3.3.3 SURVEILLANCE RE0VIREMENTS SURVEILLANCE FREQUENCY SR 3.3.1.1 Verify that the ISFSI's contribution to the 92 days radiation doses (neutron +gma) at the ISFSI perimeter fence do not exceed the specified limits. ,

4 North Anna ISFSI 3.3-5 Amendment No.

SSSC DEGRADATICN I 3.4

~

3.4 SSSC Degradation LC0 3.4 The accessible surfaces of each SSSC shall be free of damage, deterioration, and debris.

APPLICABILITY: When one or more SSSCs loaded with spent fuel are at tne ISFSI. 3

$TIONS CONDITION REQUIRED ACTION COMPLETION TIME A. LC0 not met. A.1 Take appropriate As soon as corrective action practical 3

t North Anna ISFSI 3.4-1 Amendment No.

. . o c.

SSSC DEGRADATION 3.4

-.SURVElLLANCE-REQUIREMENTS SURVEILLANCE ' FREQUENCY SR 3.4.1.1 Verify that no significant damage or 92 days deterioration of the exterior of the SSSC has occurred, and that no significant accumulation of debris on SSSC surfaces has occurred.

i North Anna ISFSI 3.4-2 Amendment No.

vi o e-Design Features 4.0 4.0 DESIGN FEATURES 4.1 Site 4.1.1 Site and Exclusien Area Boundaries The North Anna site boundaries shall be as shown in Figure 4.1-1.

4.1.2 Storace Pad The North Anna ISFSI storage pads are reinforced concrete, with nominal dimensions of 224 feet x 32 feet x 2 feet thick with a 40-foot ramp on each end for vehicle access. Each pad is designed to store 28 SSSCs arranged in two rows. The SSSCs in each row will be spaced 16 feet apart center to center. Each row of SSSCs will be spaced 16 feet apart center to center. The facility will have three storage pads, if required. Figure 3/4-1 provides a sketch of the Notth Anna ISFSI.

4.2 Storage Features 4.2.1 11.praaeCask The North Anna ISFSI is currently licensed to store spent fuel in the TN-32 dry storage cesk.

4.2.2 116raaeCaoacity The total storage capacity of the North Anna ISFSI is limited to 839.04 metric tons uranium.

North Anna ISFSI 4.0-1 Amendment No.

coe J Administrative Controls 5.0 5.0 ADMINISTRATIVE CONTROLS 5.1 General The North Anna ISFSI is located on the North Anna Power Station site and will be managed and operated by the Virginia Power staff.

The administrative controls regarding responsibilities, organization. Staff Qualification. Procedures. Programs, and Reporting Requiremer.ts shall be in accordance with the requirements of the North Anna Power Station Operating Licenses (NPF-4 and NPF-7) and associated Technical Specifications, as appropriate. except as specifically modified below.

5.2 Reporting Requirements 5.2.1 Environmental Monitorina Proaram Virginia Power shall include the North Anna ISFSI in the environmental monitoring program for the North Anna Power Station.

An environmental monitoring program is required pursuant to 10 CFR 72.44(d)(2). Virginia Power shall include the ISFSI in the Environmental Operating Report for the North Anna Power Station, and a copy shall be sr 't by May 1 of each year to the Director.

Office of Nuclear Matt. tal Safety end Safeguards.

5.2.3 Annual Radioactive Effluent Release Reoort .

An annual report, as required by 10 CFR 50.36a(a)(2), which is the North Anna Power Station Annual Radioactive Effluent Release Report, shall include the North Anna ISFSI and shall be submitted by May 1 of each year to the NRC Region 11 Office, with a copy to the Director. Office of Nuclear Material Safety and Safeguards.

This report shall specify the quantity of each of the principle radionuclides released to the environment in liquid and gaseous effluents during the previous year of operation and such other information as may be required by the Commission to estimate maximum potential radiation dose commitment to the public resulting from effluent release. The report under this specification is also recuired pursuant to 10 CFR 72.44(d)(3)

(with an exemption regarcing the requirement to submit the report within 60 days ofter January 1 of each year).  ;

North Anna ISFS1 5.0-1 Amendment No. .

{

l .

._ _ _ _ --_