{{#Wiki_filter:12/18/2008                      U.S. Nuclear Regulatory Comnnission Operations Center Event Report                    Paze I Power Reactor                                                                                    Event#        44732 Site: MCGUIRE                                    Notification Date / Time: 12/18/2008    15:54  (EST)
Unit: 1 2,          Region: 2        State
* NC        Event Date / Time: 12/18/2008              (EST)
Reactor Type:    [1] W-4-LP,[2] W-4-LP                              Last Modification: 12/18/2008 Containment Type:        ICE COND ICE COND NRC Notified by: JIM EFFINGER                                      Notifications: JAY HENSON                  R2 HQ Ops Officer: MARK ABRAMOVITZ                                                  WILLIAM RULAND              NRR Emergency Class: NON EMERGENCY                                                      PART 21 GROUP 10 CFR Section:
21.21                UNSPECIFIED PARAGRAPH Unit !Scram Code      RX Crit init Power    Initial RX Mode              Curr Power Current RX Mode 1          N          Yes      100        Power Operation              .100          i Power Operation 2          N          Yes      100        Power Operation              .100          Power Operation DEFECTIVE OPTICAL ISOLATORS "Duke Energy Carolinas, LLC (Duke) herein makes the following notification under 10CFR21.21(d)(3)(i) of defective digital optical isolators. The isolators are Commercial Grade Items dedicated by Duke. Failure analysis, conducted by the manufacturer, determined that a manufacturing defect with the isolator capacitor will cause the output voltage to drop when the isolator is not energized and there is a very light load on the output. The subject digital optical isolators are Model 175C180, manufactured by E-max Instruments (also known as Electro-Max) 13 Inverness Way, South Englewood, CO.80112. These digital optical isolators could be utilized in a variety of applications at Duke's McGuire and Catawba nuclear stations. There are no known applications for these digital optical isolators at Oconee.                            )
Initial Safety Significance: None. Defective digital optical isolators were never installed. Duke protocols require the conduct of a pre-installation bench test and a post installation test to assure these isolators perform satisfactorily in service. E-max Instruments has issued a Model 175C180 recall for all uninstalled isolators. Duke has returned all uninstalled digital optical isolators to the supplier. Duke is the only known nuclear utility purchasing E-max Instruments Model 175C180 digital optical isolators.
"The McGuire and Catawba Senior NRC Resident Inspectors were notified of this Part 21 notification on Dec 18, 2008."
 
DEC 18 2008 16:57 FR MCGUIRE CONTROL RM                                              704 875 4888 TO NRC                                                  P. 01/03 Enclosure 4.2                                                  RP/O/A/5700/010 NRC Event Notification Worksheet                                                      Page 1 of 2 STATE: 1THIS IS THE Mý;GUlRE NUCLEAR SITE IN NRC REGION 2 MAKING AN EVENT NOTIFICATION REPORT" NOTIFICATION                                    UNIT        CALLER'S NAME                                            CALLBACK TELEPHONE #;                    NRC OPERATIONS TIMEIDATE r'V.NT TIME & ZONE 11A rOEM-EVENT              POWER/MODE BEFORE rr~*          ]  or FN
[704),,_8J.9.§L"4 ENS-,1-.4LZ~10j)I 7(-
POWER/MODE AFTER OPFICER CONTACTED 4J4                  KCu*I                              DATE" (time)              (zone)
E2VENT CLASSIFICATIONS                                  I-Hr Non-Emerency                                                8-Hr Non-Emergency          IOCFR 50.72(b13 GENERAL EMERGENCY                                      (50.72 bI (a)              TS Deviation                              (72.75)(el)        Spent Fuel  Storatge SSC defect.
SITE AREA EMERGEFNCY                                                                                                          (72,75.)e2)      Spent Fuel Storage depradation.
ALERT                                                  (10,52) (a) and (b)  Accidental Criticality                          (72.75)(*3)      Fuel Storage related offaiti mndical.
OR (72.74) (n)            LoDssor theft of SNM UNUSUAL EVENT                                                                                                                (50.72 b3 (XID)'          Offsitc Medical TRANSPORTATION (10 CFR 20)                        4-I Ir Non-Emefency                                                        (50.72 b3 (1')(A))        Degradcd Condition MATERIAL/-X POSUR E (10 CFR                            (5(1,72 b2(I)) ,      TS Required S/D                                (50.72 b3 (IAMB))          Unanalyzed Condition 20)
OTHER                                                  (50.72 b2 (IV)(A))    ECCS Discharge to RCS                          (50.72 b3 (IV)(A))        Valid Actuation of System o,Id-k 4,  .z Icd)c3NLt c                              ____,_,.                                                                                        listed in Encl. 4.3.
(50.72 b2 (IV)(B))    RPS ACtualion - critical                      (50.72 b3 (V")(A))        Safe S/D Capability scram (50.72 b2 (XI))        Offsitc Notification                          (50.72 b3 (V)(8))          RHR Capability (72,75)(bl              Deviation from ISFSI                          (50.72 b3 (V)(C))          Control of Rad Release T.S.
f70.50(.)]              SNM Protective action(s)          _          (50.72 b3  (V)(D))        Aecidvonl Milignafion PHYSICAL SECURITY (73.71)                                            (50.72 b3  (X)(III))      Lost ENS (50.72 b3  (X)(I11))      Lost Other Assess./Comms (50.72 b3  (X)(Ill))      Emergeny Sien INOP 24-1 fr. Non-Eniergency Moterial/Exnosure (IOCFR20)
(72.75)(d I) Fuel Storage equipmenl failure.
(73 App () safeguards vuIlncrabilitics 26,73 Significant events involving fitnos for duty.
(70,50(bl)) Contamination event restrictions, (70.50(b2)) Equipment failure (70.50(b3)) Unplunncd medical treatment (70.50(04)) Fire/explosion damage to licen.ed materizo ISFI Certificatc ofCompliance EVENT DESCRIPTION Include: Sysltems a(i~ctd. u.lioatlon's & their initiating signals, CauLses,  Tffuctof wev¢ton plant, actions taken or plunned, etc, Continue on Enclosure 4.2 page 2 of 2 if necessary.
NOTIFICATIONS                    YES      NO          WILL        ANYTHING UNUSUAL OR NOT UNDERSTOOD?                        0    YES                  0 NO
________________              ____        BE NRC RESIDENT                              _Explain                (,_      above)
STATE(s)                                                            DID ALL SYSTEMS FUNCTION AS                        YES    0                    0 NO REQUIREDi LOCAL                              -                                                                                                                  (Explain above)
OTHER GOV AGENCIES                                                  MODE OF OPERATION                                  EST.            ADDITIONAL INFOR ON 1ACK RESTART MEDIA!PRESS RELEASE                            2      _    _      UNTIL CORRECTED                                    DATE:              0    YES___      0  NO APPROVED BY:        ______Z.                                                  'fIME/DATF:_6C_______/____
Opcrationa Shift ManagEr/Emergency Coordinator                                          (caniter)                  mm          dd      yy
 
DEC 18 2008 16:57 FR MCGUIRE CONTROL RM                                            704 875 4888 TO NRC                                              P. 02/03 Enclosure 4.2                                                  RP/O0A/5700/0 10 NRC Event Notification Worksheet                                                Page 2 of 2 RADIOLOGICAL RELEASES:;                CIIECK OR FILL IN APPLICABLE ITEMS              (spciric  detail./cxplanations should be covcrmd in evcnl description)
[QID R.2LEASE          IASEOUS RELEASE                UNPLANNED RELEASE                    {PANNED RELEASE                  fINGOING                rEMNAE ONITORED                                                  FSITE1UNMONITORED RELEASE                      S."EXCEEDED                          ALARMS )'VACUATED
      'ERSONNFL EXPOSED OR CONTAMINATED                            FFSITE PROT"CTIVE ACTIONS RECOMMENDED                              tate rcicatr path in description NOTE:              Contact Radiation Pro*ection Shift to obtain the following i9formation.
ILthe notification is due and the infoollation is not available, THEN mark "Not Available- and complete the notification,
                              'Release Rate (Ci/sccl      / T.S. LIMIT          1100 GUIDE                Total Activity (Ci)          % T.S: LIMIT              HOG GUIDE Noblc Gas                                                                          0.1 Cil/sec                                                                        100 Ci Iodine                                                                              10 uCi/srx                                                                        0.01 Ci I'zrltsrIetc                                                                        I uCi]a¢e                                                                          I mCi Liquid (excluding ilnsiiii                                                        10 uCi/miri                                                                          0.1 Ci Sdisolved sable ,ases )
Liquid (trritum)                                                                  0.2 Cilmin                                                                            5 Ci
;ECORD MONTMOR)s                        PLANT STACK            CONDENSFR/                  MAIN STEAM LINE                      SQ BLOWDOWN                        OTHER IN ALARM                                (EMF 35, 36. 37)        AIR EJECTOR              (UNIT I-EMF 24,25.26.27                    (EMF 34)
(LMF 33)              UNIT 2-EMF 10. Il. 12.13)
AD MONITOR READINGS:
LARM SL'TPOINTS3 TRIP II
'0 T.S.I LIMIT (If applicable)                                NOT APPLICABLE                                                    NOT APPLICABLE RC S OR SO TUBE LEAKS;
                                        -                              -mm                                                              -
CHECK OR FILL IN APPLICABLE ITEMS (.qpecific details/explanation. should be covered in event description)
LOCATION OF THE LEAK (e.g. SG#, valve, pipe. etc.)-
LEAK RATE: gpm/gpd                                            T.S. LIMITS EXCEEDED:                    SUDDEN OR LONG TERM DEVELOrMF.NT:
LEAK START DATE:                                    TIME:                                      4OOLANT ACTIVITY:              PRIMARY'                        SECONDARY (Last Sumple)            Xceq              oCiiml          Xe eq        mCnilml Iodine eq.              mci/ml      Iodine C9.        mCi/rn LIST OF SAFETY RELATED EQUIPMENT NOT OPERATIONAL; ENTNT DESCRIPTION (Continued from Enclosure 4.2 page I of 2)
 
DEC 18 2008 16:57 FR MCGUIRE CONTROL RM              704 875 4888 TO NRC                    P. 03/03 Duke Energy Carolinas, LLC (Duke) herein makes the following notification under IOCFR21.21 (d)(3)(i) of defective digital optical isolators. The isolators are Commercial Grade Items dedicated by Duke. Failure analysis, conducted by the manufacturer, determined that a manufacturing defect with the isolator capacitor will cause the output voltage to drop when the isolator is not energized and there is a very light load on the output. The subject digital optical isolators are Model 175C180, manufactured by E-max Instruments (also known as Electro-Max) 13 Inverness Way, South Englewood, CO 80112. These digital optical isolators could be utilized in a variety of applications at Duke's MeGuire and Catawba nuclear stations. There are no known applications for these digital optical isolators at Oconee.
Initial Safety Signifiaance: None. Defective digital optical isolators were never installed.
Duke protocols require the conduct of a pre-installation bench test and a post installation test to assure these isolators perform satisfactorily in service. E-max Instruments has issued a Model 175C 180 recall for all uninstalled isolators. Duke has returned all uninstalled digital optical isolators to the supplier. Duke is the only known nuclear utility purchasing E-max Instruments Model 175C 180 digital optical isolators.
The McGuire and Catawba Senior NRC Resident Inspectors were notified of this Part 21 notification on Dec 18, 2008.
                                          )C 88  TOTAL PAGE.03 8*}}

Latest revision as of 11:17, 14 November 2019

Duke Energy Carolinas, Llc., Deficiency Report on Defective Digital Optical Isolators
ML083540469
Person / Time
Site: Mcguire, Catawba, McGuire  Duke Energy icon.png
Issue date: 12/18/2008
From: Effinger J
Duke Energy Carolinas
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
44732
Download: ML083540469 (4)


Text

12/18/2008 U.S. Nuclear Regulatory Comnnission Operations Center Event Report Paze I Power Reactor Event# 44732 Site: MCGUIRE Notification Date / Time: 12/18/2008 15:54 (EST)

Unit: 1 2, Region: 2 State

  • NC Event Date / Time: 12/18/2008 (EST)

Reactor Type: [1] W-4-LP,[2] W-4-LP Last Modification: 12/18/2008 Containment Type: ICE COND ICE COND NRC Notified by: JIM EFFINGER Notifications: JAY HENSON R2 HQ Ops Officer: MARK ABRAMOVITZ WILLIAM RULAND NRR Emergency Class: NON EMERGENCY PART 21 GROUP 10 CFR Section:

21.21 UNSPECIFIED PARAGRAPH Unit !Scram Code RX Crit init Power Initial RX Mode Curr Power Current RX Mode 1 N Yes 100 Power Operation .100 i Power Operation 2 N Yes 100 Power Operation .100 Power Operation DEFECTIVE OPTICAL ISOLATORS "Duke Energy Carolinas, LLC (Duke) herein makes the following notification under 10CFR21.21(d)(3)(i) of defective digital optical isolators. The isolators are Commercial Grade Items dedicated by Duke. Failure analysis, conducted by the manufacturer, determined that a manufacturing defect with the isolator capacitor will cause the output voltage to drop when the isolator is not energized and there is a very light load on the output. The subject digital optical isolators are Model 175C180, manufactured by E-max Instruments (also known as Electro-Max) 13 Inverness Way, South Englewood, CO.80112. These digital optical isolators could be utilized in a variety of applications at Duke's McGuire and Catawba nuclear stations. There are no known applications for these digital optical isolators at Oconee. )

Initial Safety Significance: None. Defective digital optical isolators were never installed. Duke protocols require the conduct of a pre-installation bench test and a post installation test to assure these isolators perform satisfactorily in service. E-max Instruments has issued a Model 175C180 recall for all uninstalled isolators. Duke has returned all uninstalled digital optical isolators to the supplier. Duke is the only known nuclear utility purchasing E-max Instruments Model 175C180 digital optical isolators.

"The McGuire and Catawba Senior NRC Resident Inspectors were notified of this Part 21 notification on Dec 18, 2008."

DEC 18 2008 16:57 FR MCGUIRE CONTROL RM 704 875 4888 TO NRC P. 01/03 Enclosure 4.2 RP/O/A/5700/010 NRC Event Notification Worksheet Page 1 of 2 STATE: 1THIS IS THE Mý;GUlRE NUCLEAR SITE IN NRC REGION 2 MAKING AN EVENT NOTIFICATION REPORT" NOTIFICATION UNIT CALLER'S NAME CALLBACK TELEPHONE #; NRC OPERATIONS TIMEIDATE r'V.NT TIME & ZONE 11A rOEM-EVENT POWER/MODE BEFORE rr~* ] or FN

[704),,_8J.9.§L"4 ENS-,1-.4LZ~10j)I 7(-

POWER/MODE AFTER OPFICER CONTACTED 4J4 KCu*I DATE" (time) (zone)

E2VENT CLASSIFICATIONS I-Hr Non-Emerency 8-Hr Non-Emergency IOCFR 50.72(b13 GENERAL EMERGENCY (50.72 bI (a) TS Deviation (72.75)(el) Spent Fuel Storatge SSC defect.

SITE AREA EMERGEFNCY (72,75.)e2) Spent Fuel Storage depradation.

ALERT (10,52) (a) and (b) Accidental Criticality (72.75)(*3) Fuel Storage related offaiti mndical.

OR (72.74) (n) LoDssor theft of SNM UNUSUAL EVENT (50.72 b3 (XID)' Offsitc Medical TRANSPORTATION (10 CFR 20) 4-I Ir Non-Emefency (50.72 b3 (1')(A)) Degradcd Condition MATERIAL/-X POSUR E (10 CFR (5(1,72 b2(I)) , TS Required S/D (50.72 b3 (IAMB)) Unanalyzed Condition 20)

OTHER (50.72 b2 (IV)(A)) ECCS Discharge to RCS (50.72 b3 (IV)(A)) Valid Actuation of System o,Id-k 4, .z Icd)c3NLt c ____,_,. listed in Encl. 4.3.

(50.72 b2 (IV)(B)) RPS ACtualion - critical (50.72 b3 (V")(A)) Safe S/D Capability scram (50.72 b2 (XI)) Offsitc Notification (50.72 b3 (V)(8)) RHR Capability (72,75)(bl Deviation from ISFSI (50.72 b3 (V)(C)) Control of Rad Release T.S.

f70.50(.)] SNM Protective action(s) _ (50.72 b3 (V)(D)) Aecidvonl Milignafion PHYSICAL SECURITY (73.71) (50.72 b3 (X)(III)) Lost ENS (50.72 b3 (X)(I11)) Lost Other Assess./Comms (50.72 b3 (X)(Ill)) Emergeny Sien INOP 24-1 fr. Non-Eniergency Moterial/Exnosure (IOCFR20)

(72.75)(d I) Fuel Storage equipmenl failure.

(73 App () safeguards vuIlncrabilitics 26,73 Significant events involving fitnos for duty.

(70,50(bl)) Contamination event restrictions, (70.50(b2)) Equipment failure (70.50(b3)) Unplunncd medical treatment (70.50(04)) Fire/explosion damage to licen.ed materizo ISFI Certificatc ofCompliance EVENT DESCRIPTION Include: Sysltems a(i~ctd. u.lioatlon's & their initiating signals, CauLses, Tffuctof wev¢ton plant, actions taken or plunned, etc, Continue on Enclosure 4.2 page 2 of 2 if necessary.

NOTIFICATIONS YES NO WILL ANYTHING UNUSUAL OR NOT UNDERSTOOD? 0 YES 0 NO

________________ ____ BE NRC RESIDENT _Explain (,_ above)

STATE(s) DID ALL SYSTEMS FUNCTION AS YES 0 0 NO REQUIREDi LOCAL - (Explain above)

OTHER GOV AGENCIES MODE OF OPERATION EST. ADDITIONAL INFOR ON 1ACK RESTART MEDIA!PRESS RELEASE 2 _ _ UNTIL CORRECTED DATE: 0 YES___ 0 NO APPROVED BY: ______Z. 'fIME/DATF:_6C_______/____

Opcrationa Shift ManagEr/Emergency Coordinator (caniter) mm dd yy

DEC 18 2008 16:57 FR MCGUIRE CONTROL RM 704 875 4888 TO NRC P. 02/03 Enclosure 4.2 RP/O0A/5700/0 10 NRC Event Notification Worksheet Page 2 of 2 RADIOLOGICAL RELEASES:; CIIECK OR FILL IN APPLICABLE ITEMS (spciric detail./cxplanations should be covcrmd in evcnl description)

[QID R.2LEASE IASEOUS RELEASE UNPLANNED RELEASE {PANNED RELEASE fINGOING rEMNAE ONITORED FSITE1UNMONITORED RELEASE S."EXCEEDED ALARMS )'VACUATED

'ERSONNFL EXPOSED OR CONTAMINATED FFSITE PROT"CTIVE ACTIONS RECOMMENDED tate rcicatr path in description NOTE: Contact Radiation Pro*ection Shift to obtain the following i9formation.

ILthe notification is due and the infoollation is not available, THEN mark "Not Available- and complete the notification,

'Release Rate (Ci/sccl / T.S. LIMIT 1100 GUIDE Total Activity (Ci)  % T.S: LIMIT HOG GUIDE Noblc Gas 0.1 Cil/sec 100 Ci Iodine 10 uCi/srx 0.01 Ci I'zrltsrIetc I uCi]a¢e I mCi Liquid (excluding ilnsiiii 10 uCi/miri 0.1 Ci Sdisolved sable ,ases )

Liquid (trritum) 0.2 Cilmin 5 Ci

ECORD MONTMOR)s PLANT STACK CONDENSFR/ MAIN STEAM LINE SQ BLOWDOWN OTHER IN ALARM (EMF 35, 36. 37) AIR EJECTOR (UNIT I-EMF 24,25.26.27 (EMF 34)

(LMF 33) UNIT 2-EMF 10. Il. 12.13)

AD MONITOR READINGS:

LARM SL'TPOINTS3 TRIP II

'0 T.S.I LIMIT (If applicable) NOT APPLICABLE NOT APPLICABLE RC S OR SO TUBE LEAKS;

- -mm -

CHECK OR FILL IN APPLICABLE ITEMS (.qpecific details/explanation. should be covered in event description)

LOCATION OF THE LEAK (e.g. SG#, valve, pipe. etc.)-

LEAK RATE: gpm/gpd T.S. LIMITS EXCEEDED: SUDDEN OR LONG TERM DEVELOrMF.NT:

LEAK START DATE: TIME: 4OOLANT ACTIVITY: PRIMARY' SECONDARY (Last Sumple) Xceq oCiiml Xe eq mCnilml Iodine eq. mci/ml Iodine C9. mCi/rn LIST OF SAFETY RELATED EQUIPMENT NOT OPERATIONAL; ENTNT DESCRIPTION (Continued from Enclosure 4.2 page I of 2)

DEC 18 2008 16:57 FR MCGUIRE CONTROL RM 704 875 4888 TO NRC P. 03/03 Duke Energy Carolinas, LLC (Duke) herein makes the following notification under IOCFR21.21 (d)(3)(i) of defective digital optical isolators. The isolators are Commercial Grade Items dedicated by Duke. Failure analysis, conducted by the manufacturer, determined that a manufacturing defect with the isolator capacitor will cause the output voltage to drop when the isolator is not energized and there is a very light load on the output. The subject digital optical isolators are Model 175C180, manufactured by E-max Instruments (also known as Electro-Max) 13 Inverness Way, South Englewood, CO 80112. These digital optical isolators could be utilized in a variety of applications at Duke's MeGuire and Catawba nuclear stations. There are no known applications for these digital optical isolators at Oconee.

Initial Safety Signifiaance: None. Defective digital optical isolators were never installed.

Duke protocols require the conduct of a pre-installation bench test and a post installation test to assure these isolators perform satisfactorily in service. E-max Instruments has issued a Model 175C 180 recall for all uninstalled isolators. Duke has returned all uninstalled digital optical isolators to the supplier. Duke is the only known nuclear utility purchasing E-max Instruments Model 175C 180 digital optical isolators.

The McGuire and Catawba Senior NRC Resident Inspectors were notified of this Part 21 notification on Dec 18, 2008.

)C 88 TOTAL PAGE.03 8*