ML18302A228

From kanterella
Jump to navigation Jump to search
Itt Enidine - USNRC 10CFR Part 21 Notification
ML18302A228
Person / Time
Site: Calvert Cliffs, Palo Verde, Fermi, Catawba, Cooper, Fort Calhoun  Omaha Public Power District icon.png
Issue date: 10/19/2018
From: Gotthelf J
ITT Enidine
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML18302A228 (2)


Text

Oct.19.2018 8:33AM

~ITT October 19, 2018 Document Control Desk ITT U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Fax (301) 816ft5151

Subject:

USNRC 10CFR Part 21 Notification Gentlemen, No. 2792 P. 1 ITT Enidine 106 Commerce Way Westminster, SC 29691 Phone:(864)-647-9621 FaK: (864)-647-9674 Con1pact.Automation Product Line Turn-Act Product Line Conoftow Product Line This letter is to notify the US Nuclear Regulatory Commission of a failure to comply with EQ test report specifications.

The ITT Conoflow model GT25 series current to pressure transducer environmental qualification report 3419 lists the temperature range as-40 to 150 "F, and the linearity as 0.75% of span. on August 23, 2018, a discrepancy between the published specifications in sales literature, intemal test acceptance procedures and the environmental qualification test report was discovered. The EQ test report was not, revised at the time that sales literature and acceptance requirements were revised. Units manufactured after October, 2010 may not conform to the specifications of the EQ test report for linearity and temperature range, The EQ test report will be revised to reflect current speciflcaUons as follows:

Temperature range Oto 150 °F Linearlty: 1.5% of span Nuclear facllltie.s which use this product should evaluate the specifications to determine If these revisions could pose a safety risk.

ITT Enidihe will provide a revised EQ test report to facilities, upon request. The attached table (on page 2 of this notification) Is a list of customers who procured safety related GT25 series 1/P transducers, and the specific part numbers since 201 O. These customers will be notified of this potential product defect by October 23, 2018.

Respectfully Submitted,

~

Jeffrey B Gotthelf Engineering Manager Attachments: GT25 series 1/P transducer customer list (201 o to present)

Oct.19.2018 8:34AM ITT No. 2792 P. 2 ITT GT26 Series customer list (201 o to present)

ALMARAZ GT25CD1826 ARIZONA PUBLIC SERVICE GT25CA1826 CALVERT CLIFFS NUCLEAR GT25CD1826 DUKE ENERGY (CATAWBA NUCLEAR STATION)

GT25CA1826 GT25CD1826 CONTROL COMPONENTS INC GT.2.5C01826 E;Nl=RrECH GT25CD1826 ENRICO FERMI POWER GT25CD1826 FLOWSERVE GT26CA 1826

  • TRACTABEL (VIA GEFRAN BENELUX)

GT25CA1826 GT25CD1826 1---

KHNP GT25CA1826 KOREA HYDRO GT25CA1826 KRSKO NUCLEAR PLANT GT25CA182S NEBRASKA PUBLIC POWER GT25CA1826 ONTARIO POWER GENERATION GT25CA1826 SPX FLOW TECHNOLOGY (SPX MCKEAN)

GT25CA1826 WEIR VALVES GT25CA1826 ERGYTECH GT26CD1826 OPPG FORT CALHOUN STATION GT65FA1828 BECHTEL POWER CORPORATION (TVA)

GT25CD1826 GT65CD1826