0812612016 U.S. Nuclear Regulatory Commission Operations Center Event Report Pagel Part 21 (PAR)

Event#

52204 Rep Org: CRANE NUCLEAR, INC.

Notification Date I Time: 08/26/2016 18:00 (EDT)

Supplier: CRANE NUCLEAR, INC.

Event Date I Time: 08/03/2016 (CDT)

Last Modification: 08/26/2016 Region: 3 Docket#:

City: BOLINGBROOK Agreement State:

Yes County:

License#:

State: IL NRC Notified by: BURT ANDERSON Notifications: ANTHONY DIMITRIADIS R1DO HQ Ops Officer: DONG HWA PARK ERIC MICHEL Emergency Class: NON EMERGENCY JAMNES CAMERON 10 CFR Section:

RAY KELLAR 21.21 (d)(3)(i) _

DEFECTS AND NONCOMPLIANCE PART 21/50.55 REACTORS PART 21 - SAFETY RELATED COMPONENT WELDING BY AN UNQUALIFIED WELDER The following was excerpted from a letter by Crane Nuclear, Inc.:

"Shielded metal arc welding (SMAW) with F-5 filler metal w~s welded on safety related components by an unqualified welder.

R2DO R3DO R4DO EMAIL "Crane Nuclear Quality Assurance Manual, 12th Edition Rev. 2, dated 8/8/16 requires that welder performance qualification shall conform to the requirements of ASME Section IX for processing ASME B&PV Section Ill and safety related valve and valve part orders. During processing of a safety related order, it was identified that one welder was missing the required qualification documentation to perform weld repairs with F-5 filler metals (as defined in ASME Section IX) using the shielded metal arc welding process (SMAW). The safety hazard which could be created by such a defect could be a potential weld failure.

"Crane Nuclear has completed a review of all applicable welding records based on the welder hire date of September, 2011. We identified a total of 10 orders that were supplied with welding performed by an unqualified welder. Notification has been made to the purchasers of the affected safety related orders on the same date as this notification.

"Should youc have any questions regarding this matter, please contact Burt Anderson, Site Leader, at (630) 226-4990, Rosalie Nava, Director of Safety and Quality at (-030) 226-4940, or Jason Klein, Engineering Manager at (630) 226-4953."

The following facilities received these safety related orders: Duke-McGuire, Exelon-Byron, Duke-Brunswick, Entergy-ANO, Exelon-TM!, Exelori-Quad Cities, Exelon-Dresden.

0812612016 U.S. Nuclear Regulatory Commission Operations Center Event Report Pagel

AUG. 26. 2016 5: 17PM NO. 276 P.

P.

1:

COMMUNICATION RESIJLT.REPORT ( AUG. 26. 2016 4!46PM) * ;\\'.

  • FAX HEADER:

TRANSMITTED/STORED : AUG. 26. 2016 4: 44PM PAGE FILE MODE OPTION ADDRESS RESULT 275-~MEMORV-TX ____________________________ 13o1ai65151 _________________________ 0K-------------4;4----

/j-3d~~~J~ls020s-(

~ J'¥JI-30,, 201 {,

. A--4 /Jr)!Jtl& ~/;

f;?


~----~---------~~--.:---~---~------------------

---~--~----~----------*

E-1 HANa UP OR LIN~ FAI~

REA~QN FfR

~R~OR

. E-:3i NO AN~WE-R NUCLEAR.

seo REMINGTON BOULEVAAO Attn: Doi;:umetrt Cont:rol b.esk u_,s. Nuclear Regulmo.ry Commi&Son Washington, O.C..'.20555-001

Subject:

Telephcm9 (630)226-4900 F'lax (l!h!!0)221$-454G

°"'""""*c...,.*nuelolloar,com 1 o CFR Part 21 lnv.aliitigatlon Report Notifi~tion o1 Safety Related Component WeldinQ by an Unqualified Werdel"

Dear Sir-or-Madam:

Thi!Ol letter provides notification of the Crane Nuelcaar inveetigratlon Jnto welefll"lg of sa,fety-related componen~ by an -unqualified w.elcler. Tna infcmiati'On r-equired. for" thi~ natificatlon la provided

below:

(i) Name anc address ot'the JndiVidua/ or indivfdui!J/s in'o""ing t/Js Commlsslr:m.

The foU.o"Wing lnaiVid,uws ~re located at the above add:rea;;i.

Bun Anderson Site Leader Rosalie Nava Ol~or Safsty and Qulllli;ty J:ason Kl19in Eo9it"ICS1S>rin1&1" M:a.nsgl!lr-(ii) lderrtific"'-tlon of tf7e-bas/a o<Jmponent.s"ppijed '/'Qr 3UCh 1'adlliy or $f.£Ch actlvi:ty within the United states which.may mil to ecmply a,. contains ~ pctentitill cJ~ct Shielded me:tal arc waldlng (SMAW) wlth F-5 fill~r metal wa,.; weifdad en.i;:afl!!lty~related com~onen-ts by an r.mi:iualifiecl W'elqer.

(DI) Jdent/O~tlan of tf'le fiTTT1 avpplylng tfle baffle compoaemt which :tall& to comp/)' or contain:FI a defect.

Crane!) NUcleiar-860 Remfngton Slvd Bi:>nnsbc-001<:, lt.. eo440 (fv} Naf.uM o"f' the t;/$'/Sct: or t'allf.fni to comply and ths.s-afety hazfan;;f which 11$ c;ree.ted Ot" could be created by ;such d.erec.t or T.;Jilure. to camp/y.

F'l!ISJC 1 Of 4

AU*G.26.2016 5:17PM

!cRAN~j NUCLEAR CRANE NUCLEAR, INC.

860 REMINGTON BOULEVARD Date; August261 2016 Attn: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-001

Subject:

10 CFR Part 21 Investigation Report

.NO. 276 P. 2 Telephol'le (630) 226-4900 Fax (630)22.6-4646 WWW.cranenuolear.com BOLINGBROOK, IL 60440 Notification of Safety Related Component Welding by an Unql.lalified Welder

Dear Sir or Madam:

This letter provides notification of the Crane Nuclear investigation into welding of safety-related components by an unqualified welder. The infonnation required for this notification is provided below:

(i) Na_me and address of the individual or individuals informing the Commission.

The following individuals are located at the above address.

Burt Anderson

  • Site Leader Rosalie Nava Director Safety and Quality Jason Klein Engineering Manager (iQ Identification of the basic component supplied for such facility or such activity within the United states which may fail to comply or contains a potential defect Shielded metal arc welding (SMAW) with F-5 filler metal was welded on safety-related components by an unqualified welder.

(iii) Identification of the firm supplying the basic component which faffs to comply or contains a defect.

Crane Nuclear 860 Remington Blvd Bolingbrook, IL 60440

  • (iv) Nature of the defect or 'failure to comply and the safety hazard which is created or could be created by such defect or failure to comply.

Page 1 of4

.~

AUB. 26. 2016 5: 17PM CRANE NUCl,..EAR, INC.

860 REMINGION BOULCVARD NO. 276 P. 3 Telephone (6$0) 226-4900 Fax (630)22.6-4646 www.cranenuclear.com BOLINGBROOK, IL 60440 Crane Nuclear "Nuclear Quality Assurance Manual, 121ti Edition Rev. 2, dated 8/8/16 requires that welder performance qualification shall confonn to the requirements of ASME Section IX for processing ASME B&PV Section Ill and safety-related valve and valve part orders.

During processing of a safety-related order, it was identified that one welder was missing the required qualification documentation to perfonn weld repairs with F~5 filler metals (as defined in ASME Section IX) using the shielded metal arc weldi~g process (SMAW).

. The safety hazard which could be created by such a defect could be a potential weld failure.

(v) The date on which the information of such defect or failure to comply was obtained.

A concern was initially raised on 8/3/16 and Corrective Action Report 16-35 was initiated on 8/9/16 to address the deviation.

(vi) In the case of a basic component which contains a defect or fails to comply, the number and location of these components in use at, supplied for, being supplied for, or may be supplied for, manufactured, or being manufactured for one or more facilities or activities subject to the regulations in this part.

Crane Nuclear has completed a review of all applicable welding records based on the welder hire date of September, 2011. We identified a total of 1 O orders that were supplied with welding performed by an unqualified welder.

Notification has been made to the purchasers of the affected safety related orders on the same date as this notification for all of the following:

Valves:

1. CNI SO# 42061-01, Duke, McGuire, P.O. 00167728 - Quantity shipped= 1, Walworth, 8" Gate valve, Fig 5202 WE, Class 150, ASME Class 2, 1998 Ed., 2000 Add. Va.Ive S/N E2647, component affected, wedge.
2. CNI SO# 42333-01, Exelon, Byron, P.O. 00503961 - Quantity shipped ::;:: 2, Flowseal, 30" Butterfly Valve, Fig 1WC-221LGX-8DG, Class 150, ASME Class 3, 1974 Ed., Summer 75 Add. Valve S/N's E2647 and E2897, component affected) adapter plate sub-assembly.
3. CNI SO# 42529~01, Duke McGuire, P.O. 00171407-Quantity shipped~ 1, Crane, 8" Gate Valve, Fig 47 % UF-SPL, Class 150, ASME Class 3, 1998 Ed., 20000 Add. Valve SIN E3189, component affected, wedge.
4. CNI SO# 44550-02, Duke, Brunswick, P~O. 00755501 - Quantity sh.ipped ;;;;; 1, Walworth, 3D, Fig 5247PS, Class 900, ASME Class 3, 1986 Ed. Valve SIN E6287, component affected, BodyNoke.
5. CNJ $0#46140-02, Areva, Wolsong, P.O. 1015062705-Quantity shipped= 1, Flowseal, 12n, Fig 12-1LA-221XGB-3XG, Class 150, ASME Class 2, 2013 Ed. Valve S/N E7071, component affected, Disc.

Page2of4

A~G. 26. 2016 5: 18PM NUCLEAR CRANE NUCLEAR, INC.

860 REMINGTON BOULEVARD Parts:

NO. 2 7 6 P. 4 Telephone (630).226-4900 Fax (630)2.26-4646 www.cranenuclear.com BOLINGBROOK, IL 60440

1. CNI SO# 39064-01, Entergy, ANO, P.O. 10314628 ~Quantity shipped ;::: 1, Disc P/N D~

50724, for an Aloyco 24" Gate Valve, Fig. N-9126-EMO-SP, Class 150, ASME Class 2, 1971 Ed., summer 72 Add. Wedge SIN E1056.

2. CNI SO# 42888-01, Exelon, TMI, P.O. 80 053409-Quantity shipped= 1, Cover PIN 44956, for an Aloyco 8" Swing Check Valve, Fig. N-376-SP, Class 150, Non-Code, Safety Related.

Cover SIN E3352.

3. CNI SO# 43330-01, Exelon, Quad Cities, P.O. 00516018 ~ Quantity shipped,;;: 2, Disc/Lifting Nut P/N CB02868, for a Chapman 18" Tilting Disc Check Valve, Fig. L973, Class 900, Non-Code, Safety Related. D1sc/Lifting Nuts/N's E4058/E4610.

4, CNI SO# 43528-01, Exelon, Dresden, P.O. 00518985 - Quantity shipped;; 3, Disc/Lifting Nut PIN per description, for a Chapman 18" Tilting Disc Check Valve, Fig. L973, Class 900, Non-Code, Safety Related.

Disc/Lifting Nut S/N's E4387/E80577-5, E4388/E4061 and E4389/E4062.

5. CNI SO# 46154-01, Exelon, Dresden, P.O. 00564360 ~Quantity shipped; 1 Disc/Lifting Nut P/N per description, for a Chapman 18" Tilting Disc Check Valve, Fig. L973, Class 9001 Non-Code, Safety Related. Disc/Lifting Nut S/N's E6936/E6937.

Crane N*u.clear is currently evaluating these sales orders for recommended action.

(vii) The corrective action which has been, is being, or will be taken; the name of the individual or organization responsible for the action; and the length of time that has been or Will be taken to complete the action.

Corrective Action being taken by Crane Nuclear is expected to be completed on or before September 30, 2016 as follows:

1) Corrective Action Report 16-35 generated to determine root cause and implement appropriate corrective actions to prevent reoccurrence
2) Review of the above sales order to identify scope of welding for recommended action concerning the affected components.
3) Qualification of the welder on the SMAW process utilizing F-5 filler metal in accordance with ASME Section IX.

(viii) Any advice related to the defect or failure to comply about the facility, activity, or basic component that has been, is being, or will be given to purchasers or licensees.

Crane Nuclear will notify the respective customer for the orders that have been identified to date.

(lx) In the case of an early site permit, the,entities to whom an early site permit was transferred Not applicable.

Page3 of4

"

  • A~. 26. 2016 5:18PM

[cRAN~ NUCLEAR CRANE NUCLEAR, INC.

860 REMINGION BOULEVARD NO. 276 P. 5 Telephone-(630) 226-4900 Fax (630)226-4646 www.cr.menuclear.com BOLINGBROOK, IL 60440 Should you have any questions regarding this matter, please contact Burt Anderson, Site Leader, at (630) 226-4990, Rosalie Nava, Director of Safety and Quality at (630) 226-4940, or Jason Klein, Engineering Manager at (630) 226-4953.

Regards, crane Nuclear, Inc.

Burt Anderson Site Leader Page4of4