Thermo Gamma-Metrics, LLC - Part 21 Report Regarding Shutdown Margin Monitor Environmental Qualification Noncompliance
ML15049A458
Person / Time
Site: Millstone, Calvert Cliffs, Salem, Mcguire, Catawba, Saint Lucie, Watts Bar, Sequoyah, Byron, Arkansas Nuclear, Seabrook, Vogtle, South Texas, McGuire  
Issue date: 02/06/2015
From: Artaud C
Thermo Gamma-Metrics
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
50791
Download: ML15049A458 (6)


Text

02106/2015 U.S. Nuclear Regulatory Commission Operations Center Event Report Page I Part 21 (PAR)

Event#

50791 Rep Org: THERMO GAMMA-METRICS LLC Notification Date I Time: 02/06/2015 13:17 (EST)

Supplier: THERMO GAMMA-METRICS LLC Event Date I Time: 02/06/2015 (PST)

Last Modification: 02/06/2015 Region: 4 Docket #:

City:

SAN DIEGO Agreement State:

Yes County:

License #:

State:

CA NRC Notified by: CLARK ARTAUD Notifications: ANNE DeFRANCISCO R1DO HQ Ops Officer: DANIEL MILLS ROBERT HAAG R2DO Emergency Class: NON EMERGENCY LAURA KOZAK R3DO 10 CFR Section:

GEOFFREY MILLER R4DO 21.21(d)(3)(i)

DEFECTS AND NONCOMPLIANCE PART 21/50.55 REACTORS EMAIL PART 21 REPORT - SHUTDOWN MARGIN MONITOR ENVIRONMENTAL QUALIFICATION NONCOMPLIANCE The following is an excerpt of a report received from the vendor via email:

"A deviation has been identified in the SDMM supplied by Thermo Gamma-Metrics LLC. The SDMM will fail during conditions of simultaneous high temperature and high humidity less than the values reported in Qualification Test Report (QTR) 010. Testing has indicated the SDMM would not properly operate above a certain value of moisture content corresponding to a dew point of around 128°F. QTR 010 listed qualified temperature and humidity conditions corresponding to a dew point of around 136°F."

The vendor has issued a revised qualification test report which documents the revised qualified conditions for the affected SDMMs.

The following plants are potentially affected: ANO U2; Millstone U3; Prairie Island UI & U2; Seabrook UI & U2; South Texas Ul & U2; St. Lucie Ul; Catawba Ul & U2; McGuire Ul & U2; Salem Ul & U2; Calvert Cliffs Ul & U2; Almaraz Ul & U2; Sequoyah U1 & U2; Watts Bar Ul & U2; Vogtle Ul & U2; Byron Ul & U2; Ringhals U2, U3 & U4.

J/6.c

Thermo Gamma-Metrics LLC 10010 Mesa Rim Road San Diego, CA 92121 USA Phone:

(858) 450-9811 Fax:

(858) 452-9250 February 6, 2015 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001

Subject:

10 CFR Part 21 Notification of Shutdown Margin Monitor Noncompliance

Enclosure:

(1) Report Notification Information This letter provides information concerning an evaluation performed by Thermo Gamma-Metrics LLC, a part of Thermo Fisher Scientific, regarding potential noncompliance of our Shutdown Margin Monitors.

Based upon the evaluation, Thermo Gamma-Metrics has determined that a Reportable Condition under 10 CFR Part 21 exists for plants listed herein. The information contained in this document informs the NRC of the conclusions and recommendations derived from Thermo Gamma-Metrics' evaluation of this issue.

Sincerely, Clark J. Artaud Global Commercial Director Nuclear Market tSIeNT F Is r Apartof:

SC IEN TIFtIC

TGM Part 21 Notification February 6, 2015 Page 1 Report Notification Information (i)

Name and address of the individual or individuals informing the Commission.

Clark J. Artaud Global Commercial Director Robert E. Barnes Product Line Manager Jeffery S. Tuetken Senior Electrical Engineer Thermo Gamma-Metrics LLC 10010 Mesa Rim Road San Diego, CA 92121 (ii)

Identification of the facility, the activity, or the basic component supplied for such facility which falls to comply or contains a defect.

Shutdown Margin Monitors (SDMM) are installed at the following plants:

SDMM Part Numbers Site Unit Customer Generic ANO Unit 2 900010-101 200171-101 Millstone 3 900013-102 200978-102 Prairie Island 1 900029-101 200171-101 Prairie Island 2 900029-101 200171-101 Seabrook 1 900141-101 200171-101 Seabrook 2 900141-101 200171-101 South Texas 1 900063-101 200171-101 South Texas 2 900063-101 200171-101 St. Lucie 1 900094-101 200171-101 Catawba 1 900120-101 200171-101 Catawba 2 900120-101 200171-101 Catawba 1 900532-101 202051-103 Catawba 2 900532-101 202051-103 McGuire 1 900121-101 200171-101 McGuire 2 900121-101 200171-101 McGuire 1 900521-101 202051-102 McGuire 2 900521-101 202051-102 Salem 1 900135-101 200171-101 Salem 2 900135-101 200171-101 Calvert Cliffs 1 900158-101 200171-101 Enclosure (1)

TGM Part 21 Notification February 6, 2015 Page 2 Calvert Cliffs 2 900158-101 200171-101 Almaraz 1 900280-101 200972-103 Almaraz 2 900280-101 200972-103 Sequoyah 1 900185-101 200972-102 Sequoyah 2 900185-101 200972-102 Watts Bar 1 900238-101 200972-102 Watts Bar 2 900602-101 202646-101 Vogtle 1 900414-101 201878-101 Vogtle 2 900414-101 201878-101 Byron 1 900448-101 202051-101 Byron 2 900448-101 202051-101 Ringhals 2 900265-102 200978-103 Ringhals 3 900265-101 201253-101 Ringhals 4 900265-101 201253-101 (iii)

Identification of the firm constructing the facility or supplying the basic component which fails to comply or contains a defect.

The SDMMs listed above were designed and fabricated by Thermo Gamma-Metrics.

(iv)

Nature of the defect or failure to comply and the safety hazard which is created or could be created by such defect or failure to comply.

A deviation has been identified in the SDMM supplied by Thermo Gamma-Metrics LLC, a part of Thermo Fisher Scientific, to nuclear power plants. Affected part numbers and plants are provided above in sub-paragraph (ii). The SDMM will fail during conditions of simultaneous high temperature and high humidity less than the values reported in Qualification Test Report (QTR) 010.

Testing has indicated the SDMM would not properly operate above a certain value of moisture content corresponding to a dew point of around 1280F. QTR 010 listed qualified temperature and humidity conditions corresponding to a dew point of around 136 0F.

The table and corresponding chart below summarize the SDMM revised qualified conditions. Further details are provided in QTR 902.

Parameter Qualified Conditions Pressure (psig)

Atmospheric Temperature (OF) 40 - 1400 F 1300 F @ 95% RH Relative Humidity (% saturation) 7 - 95%

71% @ 1400 F Input:

VAC 104 - 133 VAC Hz 53-67 Hz Enclosure (1)

TGM Part 21 Notification February 6, 2015 Page 3 QTR 902 SDMM ENVIRONMENTAL QUALIFICATION LEVEL 95 87 79 71 S63 k 55 "E47 Z 39 Z~ 31 m23 15 40 50 60 70 80 90 100 110 120 130 140 Temperature (0 F)

Thermo Gamma-Metrics cannot determine by itself if the deviation represents a substantial safety hazard for those power plants using the SDMM in a safety related application.

The SDMM, typically installed in the Control Room, may be used to provide reactor protection for a boron dilution event or high flux at shutdown condition.

The failure mode is for the SDMM to 1) display an error code in the window usually displaying neutron counts per second, and 2) generate a high neutron counts alarm.

This is considered the fail safe condition as it would cause some plants to increase the reactor shutdown margin.

(v)

The date on which the information of such defect or failure to comply was obtained.

Thermo Gamma-Metrics Engineers identified the qualification level deviation while performing environmental qualification on a replacement component used in the Shutdown Margin Monitor.

A Potential Reportable Condition Evaluation in accordance with 10 CFR Part 21 was initiated on December 8, 2014 based on our Corrective Action Request (CAR)14-046.

(vi)

In the case of a basic component which contains a defect or fails to comply, the number and location of these components in use at, supplied for, being supplied for, or may be supplied for, manufactured, or being manufactured for one or more facilities or activities subject to the regulations in this part.

See sub-paragraph (ii).

Enclosure (1)

TGM Part 21 Notification February 6, 2015 Page 4 (vii)

The corrective action, which has been, is being, or will be taken; the name of the individual or organization responsible for the action; and the length of time that has been or will be taken to complete the action.

The corrective action is for Thermo Gamma-Metrics to retest and re-qualify the SDMM for the conditions it will operate properly.

Qualification Test Report (QTR) 902 documents this effort and the qualified conditions as provided in the table and chart in sub-paragraph (iv). There is no effort underway to modify the design of the SDMM to meet the environmental conditions of QTR 010. QTR 902 is available now.

Thermo Gamma-Metrics is notifying plants with SDMMs (to be completed by Feb. 6).

(viii) Any advice related to the defect or failure to comply about the facility, activity, or basic component that has been, is being, or will be given to purchasers or licensees.

All plants using a SDMM should review and hold QTR 902 in addition to QTR 010. The plants should verify the qualified conditions envelope the required conditions for the location where the SDMM is used.

Based on the plant specifications we have reviewed, we believe that the updated (new) environmental qualifications of the SDMM will still overlap plant's mild (control room) environment maximum (abnormal) conditions.

It is not likely any plant has experienced this failure of the SDMM under these conditions.

First, the environmental conditions in the locations where the SDMM is installed likely has never exceeded a dew point of 1000F. Second, it is even less likely that a boron dilution or high flux at shutdown event occurred during such extreme environmental conditions.

(ix)

In the case of an early site permit, the entities to whom an early site permit was transferred.

Not applicable - this is not an early site permit concern.

Should you have any questions regarding this matter, please contact Rob Barnes, Product Line and Service Manager, Thermo Gamma-Metrics LLC, at (858) 882-1356.