ML103540481: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(StriderTol Bot change)
 
(5 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML103540481
| number = ML103540481
| issue date = 12/20/2010
| issue date = 12/20/2010
| title = Salem Nuclear Generating Station, Unit Nos. 1 and 2, Draft Request for Additional Information (TAC Nos. ME3574 and ME3575)
| title = Draft Request for Additional Information
| author name = Ennis R B
| author name = Ennis R
| author affiliation = NRC/NRR/DORL/LPLI-2
| author affiliation = NRC/NRR/DORL/LPLI-2
| addressee name = Chernoff H K
| addressee name = Chernoff H
| addressee affiliation = NRC/NRR/DORL/LPLI-2
| addressee affiliation = NRC/NRR/DORL/LPLI-2
| docket = 05000272, 05000311
| docket = 05000272, 05000311
| license number =  
| license number =  
| contact person = Ennis R B, NRR/DORL, 415-1420
| contact person = Ennis R, NRR/DORL, 415-1420
| case reference number = TAC ME3574, TAC ME3575
| case reference number = TAC ME3574, TAC ME3575
| document type = Memoranda, Request for Additional Information (RAI)
| document type = Memoranda, Request for Additional Information (RAI)
Line 18: Line 18:


=Text=
=Text=
{{#Wiki_filter:}}
{{#Wiki_filter:December 20, 2010 MEMORANDUM TO:          Harold K. Chernoff, Chief Plant Licensing Branch I-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation FROM:                    Richard B. Ennis, Senior Project Manager /ra/
Plant Licensing Branch I-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
 
==SUBJECT:==
SALEM NUCLEAR GENERATING STATION, UNIT NOS. 1 AND 2, DRAFT REQUEST FOR ADDITIONAL INFORMATION (TAC NOS. ME3574 AND ME3575)
The attached draft request for information (RAI) was transmitted on December 20, 2010, to Mr. Jeff Keenan of PSEG Nuclear LLC (the licensee). This information was transmitted to facilitate an upcoming conference call in order to clarify the licensee=s amendment request for Salem Nuclear Generating Station (Salem), Unit Nos. 1 and 2, dated March 23, 2010, as supplemented on November 19, 2010. The proposed amendment would modify the Technical Specifications by relocating specific surveillance frequencies to a licensee-controlled document.
The proposed amendment is based on Nuclear Regulatory Commission (NRC)-approved Technical Specification Task Force (TSTF) Traveler TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control - RITSTF [Risk-Informed TSTF] Initiative 5b.
This memorandum and the attachment do not convey or represent an NRC staff position regarding the licensees request.
Docket Nos. 50-272 and 50-311
 
==Attachment:==
Draft RAI
 
December 20, 2010 MEMORANDUM TO:          Harold K. Chernoff, Chief Plant Licensing Branch I-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation FROM:                    Richard B. Ennis, Senior Project Manager /ra/
Plant Licensing Branch I-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
 
==SUBJECT:==
SALEM NUCLEAR GENERATING STATION, UNIT NOS. 1 AND 2, DRAFT REQUEST FOR ADDITIONAL INFORMATION (TAC NOS. ME3574 AND ME3575)
The attached draft request for information (RAI) was transmitted on December 20, 2010, to Mr. Jeff Keenan of PSEG Nuclear LLC (the licensee). This information was transmitted to facilitate an upcoming conference call in order to clarify the licensee=s amendment request for Salem Nuclear Generating Station (Salem), Unit Nos. 1 and 2, dated March 23, 2010, as supplemented on November 19, 2010. The proposed amendment would modify the Technical Specifications by relocating specific surveillance frequencies to a licensee-controlled document.
The proposed amendment is based on Nuclear Regulatory Commission (NRC)-approved Technical Specification Task Force (TSTF) Traveler TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control - RITSTF [Risk-Informed TSTF] Initiative 5b.
This memorandum and the attachment do not convey or represent an NRC staff position regarding the licensee's request.
Docket Nos. 50-272 and 50-311
 
==Attachment:==
Draft RAI DISTRIBUTION PUBLIC LPL1-2 Reading RidsNrrDorlLpl1-2 Resource RidsNrrDorlDpr Resource RidsNrrPMSalem Resource AHowe, NRR/DRA/APLA ACCESSION NO.: ML103540481 OFFICE      LPL1-2/PM NAME        REnnis DATE        12/20/2010 OFFICIAL RECORD COPY
 
DRAFT REQUEST FOR ADDITIONAL INFORMATION REGARDING PROPOSED LICENSE AMENDMENT RISK-INFORMED RELOCATION OF SURVEILLANCE FREQUENCY REQUIREMENTS SALEM NUCLEAR GENERATING STATION, UNIT NOS. 1 AND 2 DOCKET NOS. 50-272 AND 50-311 By letter dated March 23, 2010, as supplemented by letter dated November 19, 2010, (Agencywide Documents Access and Management System (ADAMS) Accession Nos.
ML100910154 and ML103230482, respectively), PSEG Nuclear LLC (PSEG or the licensee) submitted an amendment request for Salem Nuclear Generating Station (Salem), Unit Nos. 1 and 2. The proposed amendment would modify the Technical Specifications by relocating specific surveillance frequencies to a licensee-controlled document. The proposed amendment is based on Nuclear Regulatory Commission (NRC)-approved Technical Specification Task Force (TSTF) Traveler TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control - RITSTF [Risk-Informed TSTF] Initiative 5b.
The NRC staff has reviewed the information the licensee provided that supports the proposed amendment and would like to discuss the following issues to clarify the submittal.
In Table 2-1 of Attachment 2 of the March 23, 2010, submittal, the licensee has provided a tabulation of the findings from the 2008 peer review conducted to assess the Salem internal events PRA model against the requirements of capability category II of the internal events PRA standard. Several findings were characterized by the peer reviewer as documentation deficiencies (rather than an actual technical issue) while in other cases it appears that the licensee has determined the finding to be a documentation deficiency.
In its initial review, the NRC staff requested additional information on several of these peer review findings which were characterized as related to documentation, and not to the technical adequacy of the model. This request for additional information (RAI) was satisfied by the November 19, 2010, response by PSEG.
In developing its safety evaluation of this amendment request, the NRC staff has determined that additional peer review findings, characterized by the licensee as related to documentation, need further justification for the staff to find the internal events PRA model technically adequate to support the application. The licensee is therefore requested to respond to the following additional RAI:
: 1.        Finding IE-A5-01: Describe how events occurring during plant shutdown or which resulted in a controlled plant shutdown are addressed in the development of initiating events, and confirm that the supporting requirement of the standard is met except for adequacy of the documentation.
: 2.        Finding AS-A7-01: Describe how subsuming of non-minimal sequences in the single-top fault tree model has been determined not to result in a loss of risk insights or masking of importance of non-standard configurations, and confirm that the supporting requirement of the standard is met except for adequacy of the documentation.
Attachment
: 3. Finding AS-A7-01: Describe how the potential for flooding damage prior to isolation of the interfacing system flowpath has been evaluated and determined to not affect the capability to achieve safe shutdown, and confirm that the supporting requirement of the standard is met except for adequacy of the documentation.
: 4. Finding AS-A8-01: The peer review team identified three technical issues: (1) recovery of mitigating systems following restoration of offsite power; (2) double crediting of offsite power recovery; and (3) mission times of the mitigating systems. Only the third item appears to be addressed directly by the entry in Table 2-1 as a documentation issue.
Address the full scope of this finding, and confirm that the supporting requirement of the standard is met except for adequacy of the documentation.
: 5. Findings SY-A6-01, SY-A8-01, SY-A10-01, SY-A12-01, and SY-A13-01: Collectively these findings relate to system and data boundaries and modeled failure modes. Failure modes for some components are specifically identified as excluded or otherwise missing from the model. Describe how these issues were determined not to represent technical deficiencies and confirm that the supporting requirements of the standard are met except for adequacy of the documentation.}}

Latest revision as of 07:35, 21 March 2020

Draft Request for Additional Information
ML103540481
Person / Time
Site: Salem  PSEG icon.png
Issue date: 12/20/2010
From: Richard Ennis
Plant Licensing Branch 1
To: Chernoff H
Plant Licensing Branch 1
Ennis R, NRR/DORL, 415-1420
References
TAC ME3574, TAC ME3575
Download: ML103540481 (4)


Text

December 20, 2010 MEMORANDUM TO: Harold K. Chernoff, Chief Plant Licensing Branch I-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation FROM: Richard B. Ennis, Senior Project Manager /ra/

Plant Licensing Branch I-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation

SUBJECT:

SALEM NUCLEAR GENERATING STATION, UNIT NOS. 1 AND 2, DRAFT REQUEST FOR ADDITIONAL INFORMATION (TAC NOS. ME3574 AND ME3575)

The attached draft request for information (RAI) was transmitted on December 20, 2010, to Mr. Jeff Keenan of PSEG Nuclear LLC (the licensee). This information was transmitted to facilitate an upcoming conference call in order to clarify the licensee=s amendment request for Salem Nuclear Generating Station (Salem), Unit Nos. 1 and 2, dated March 23, 2010, as supplemented on November 19, 2010. The proposed amendment would modify the Technical Specifications by relocating specific surveillance frequencies to a licensee-controlled document.

The proposed amendment is based on Nuclear Regulatory Commission (NRC)-approved Technical Specification Task Force (TSTF) Traveler TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control - RITSTF [Risk-Informed TSTF] Initiative 5b.

This memorandum and the attachment do not convey or represent an NRC staff position regarding the licensees request.

Docket Nos. 50-272 and 50-311

Attachment:

Draft RAI

December 20, 2010 MEMORANDUM TO: Harold K. Chernoff, Chief Plant Licensing Branch I-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation FROM: Richard B. Ennis, Senior Project Manager /ra/

Plant Licensing Branch I-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation

SUBJECT:

SALEM NUCLEAR GENERATING STATION, UNIT NOS. 1 AND 2, DRAFT REQUEST FOR ADDITIONAL INFORMATION (TAC NOS. ME3574 AND ME3575)

The attached draft request for information (RAI) was transmitted on December 20, 2010, to Mr. Jeff Keenan of PSEG Nuclear LLC (the licensee). This information was transmitted to facilitate an upcoming conference call in order to clarify the licensee=s amendment request for Salem Nuclear Generating Station (Salem), Unit Nos. 1 and 2, dated March 23, 2010, as supplemented on November 19, 2010. The proposed amendment would modify the Technical Specifications by relocating specific surveillance frequencies to a licensee-controlled document.

The proposed amendment is based on Nuclear Regulatory Commission (NRC)-approved Technical Specification Task Force (TSTF) Traveler TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control - RITSTF [Risk-Informed TSTF] Initiative 5b.

This memorandum and the attachment do not convey or represent an NRC staff position regarding the licensee's request.

Docket Nos. 50-272 and 50-311

Attachment:

Draft RAI DISTRIBUTION PUBLIC LPL1-2 Reading RidsNrrDorlLpl1-2 Resource RidsNrrDorlDpr Resource RidsNrrPMSalem Resource AHowe, NRR/DRA/APLA ACCESSION NO.: ML103540481 OFFICE LPL1-2/PM NAME REnnis DATE 12/20/2010 OFFICIAL RECORD COPY

DRAFT REQUEST FOR ADDITIONAL INFORMATION REGARDING PROPOSED LICENSE AMENDMENT RISK-INFORMED RELOCATION OF SURVEILLANCE FREQUENCY REQUIREMENTS SALEM NUCLEAR GENERATING STATION, UNIT NOS. 1 AND 2 DOCKET NOS. 50-272 AND 50-311 By letter dated March 23, 2010, as supplemented by letter dated November 19, 2010, (Agencywide Documents Access and Management System (ADAMS) Accession Nos.

ML100910154 and ML103230482, respectively), PSEG Nuclear LLC (PSEG or the licensee) submitted an amendment request for Salem Nuclear Generating Station (Salem), Unit Nos. 1 and 2. The proposed amendment would modify the Technical Specifications by relocating specific surveillance frequencies to a licensee-controlled document. The proposed amendment is based on Nuclear Regulatory Commission (NRC)-approved Technical Specification Task Force (TSTF) Traveler TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control - RITSTF [Risk-Informed TSTF] Initiative 5b.

The NRC staff has reviewed the information the licensee provided that supports the proposed amendment and would like to discuss the following issues to clarify the submittal.

In Table 2-1 of Attachment 2 of the March 23, 2010, submittal, the licensee has provided a tabulation of the findings from the 2008 peer review conducted to assess the Salem internal events PRA model against the requirements of capability category II of the internal events PRA standard. Several findings were characterized by the peer reviewer as documentation deficiencies (rather than an actual technical issue) while in other cases it appears that the licensee has determined the finding to be a documentation deficiency.

In its initial review, the NRC staff requested additional information on several of these peer review findings which were characterized as related to documentation, and not to the technical adequacy of the model. This request for additional information (RAI) was satisfied by the November 19, 2010, response by PSEG.

In developing its safety evaluation of this amendment request, the NRC staff has determined that additional peer review findings, characterized by the licensee as related to documentation, need further justification for the staff to find the internal events PRA model technically adequate to support the application. The licensee is therefore requested to respond to the following additional RAI:

1. Finding IE-A5-01: Describe how events occurring during plant shutdown or which resulted in a controlled plant shutdown are addressed in the development of initiating events, and confirm that the supporting requirement of the standard is met except for adequacy of the documentation.
2. Finding AS-A7-01: Describe how subsuming of non-minimal sequences in the single-top fault tree model has been determined not to result in a loss of risk insights or masking of importance of non-standard configurations, and confirm that the supporting requirement of the standard is met except for adequacy of the documentation.

Attachment

3. Finding AS-A7-01: Describe how the potential for flooding damage prior to isolation of the interfacing system flowpath has been evaluated and determined to not affect the capability to achieve safe shutdown, and confirm that the supporting requirement of the standard is met except for adequacy of the documentation.
4. Finding AS-A8-01: The peer review team identified three technical issues: (1) recovery of mitigating systems following restoration of offsite power; (2) double crediting of offsite power recovery; and (3) mission times of the mitigating systems. Only the third item appears to be addressed directly by the entry in Table 2-1 as a documentation issue.

Address the full scope of this finding, and confirm that the supporting requirement of the standard is met except for adequacy of the documentation.

5. Findings SY-A6-01, SY-A8-01, SY-A10-01, SY-A12-01, and SY-A13-01: Collectively these findings relate to system and data boundaries and modeled failure modes. Failure modes for some components are specifically identified as excluded or otherwise missing from the model. Describe how these issues were determined not to represent technical deficiencies and confirm that the supporting requirements of the standard are met except for adequacy of the documentation.