Name:            J.F. Swan Employer:        The Hartford Steam Boiler Inspection & Insurance Company of Connecticut Business          200 Ashford Center North Address:          Suite 205 Atlanta, GA 30338-4860 (800) 417-3721 www.hsbct.com McGuire Unit 2                                                            Page 5 of 5 Outage 1/EOC-16                                                            Revision 0 Section 1                                                                  May 26, 2005
Name:            J.F. Swan Employer:        The Hartford Steam Boiler Inspection & Insurance Company of Connecticut Business          200 Ashford Center North Address:          Suite 205 Atlanta, GA 30338-4860 (800) 417-3721 www.hsbct.com McGuire Unit 2                                                            Page 5 of 5 Outage 1/EOC-16                                                            Revision 0 Section 1                                                                  May 26, 2005


                -
2.0    Third Ten-Year Interval Inspection Status The completion status of inspections required by the 1998 ASME Code Section Xl, 2000 Addenda is summarized in this section. The requirements are listed by the ASME Section Xl Examination Category as defined in Table IWB-2500-1 for Class 1 Inspections, Table IWC-2500-1 for Class 2 Inspections, and IWF-2500-1 for Class 1,2 and 3 Component Supports. Augmented Inspections are also included.
2.0    Third Ten-Year Interval Inspection Status The completion status of inspections required by the 1998 ASME Code Section Xl, 2000 Addenda is summarized in this section. The requirements are listed by the ASME Section Xl Examination Category as defined in Table IWB-2500-1 for Class 1 Inspections, Table IWC-2500-1 for Class 2 Inspections, and IWF-2500-1 for Class 1,2 and 3 Component Supports. Augmented Inspections are also included.
During the McGuire Third 10 Year Interval piping welds will be examined under the Risk Informed Inservice Inspection program developed in accordance with methodology contained in the Westinghouse Owners Group (WOG) Topical Report, WCAP-14572, Revision 1-NP-A. Request for Relief 01-005 was submitted to the NRC seeking approval to incorporate the Risk Informed Program into the Third 10 Year Interval [SI Plan for McGuire Unit 2. The NRC approved use of this program per SER dated June 12, 2002. Previous code examination Categories B-F, B-J, C-F-1, and C-F-2 will now be combined under the new Risk Informed Category R-A.
During the McGuire Third 10 Year Interval piping welds will be examined under the Risk Informed Inservice Inspection program developed in accordance with methodology contained in the Westinghouse Owners Group (WOG) Topical Report, WCAP-14572, Revision 1-NP-A. Request for Relief 01-005 was submitted to the NRC seeking approval to incorporate the Risk Informed Program into the Third 10 Year Interval [SI Plan for McGuire Unit 2. The NRC approved use of this program per SER dated June 12, 2002. Previous code examination Categories B-F, B-J, C-F-1, and C-F-2 will now be combined under the new Risk Informed Category R-A.
Line 132: Line 131:
McGuire Unit 2                                                                        Page 2 of 4 Outage 1/EOC-16                                                                        Revision 0 Section 2                                                                              May 26, 2005
McGuire Unit 2                                                                        Page 2 of 4 Outage 1/EOC-16                                                                        Revision 0 Section 2                                                                              May 26, 2005


          -
Class 2 Inspections Examination            Description          Inspections  Inspections  Percentage      Deferral Category                                    Reqluired    Completed    Completed        Allowed C-A      Pressure Retaining Welds          28          3          10.71%            No in Pressure Vessels        .                                            .      -
Class 2 Inspections Examination            Description          Inspections  Inspections  Percentage      Deferral Category                                    Reqluired    Completed    Completed        Allowed C-A      Pressure Retaining Welds          28          3          10.71%            No in Pressure Vessels        .                                            .      -
C-B      Pressure Retaining Nozzle          11          3          27.27%            No Welds in Vessels C-C      Welded Attachments for            18          3          16.66%            No Vessels, Piping, Pumps and Valves C-D      Pressure Retaining Bolting        N/A          N/A          N/A            N/A Greater Than 2" in Diameter Reference C-F-1      Pressure Retaining Welds    Risk Informed in Austenitic Stainless    Program Rol.
C-B      Pressure Retaining Nozzle          11          3          27.27%            No Welds in Vessels C-C      Welded Attachments for            18          3          16.66%            No Vessels, Piping, Pumps and Valves C-D      Pressure Retaining Bolting        N/A          N/A          N/A            N/A Greater Than 2" in Diameter Reference C-F-1      Pressure Retaining Welds    Risk Informed in Austenitic Stainless    Program Rol.
Line 152: Line 150:
CATEGORY B-D, Full Penetration Welded                      INSERVICE INSPECTION PLAN MANAGEMENT Nozzels In Vessels - Inspection Program B                Inservice Inspection Database Management System                                    Plan Report Steam Generators (Primary Side)                                        McGuire 2                                                          Page 1 Inservice Inspection Plan for Interval 3 Outage 1                                05/25/2005 ITEM NUMBER            ID NUMBER  SYS ISO/DWG 3NUMBERS        PROC      INSP REQ MAT/SCH DIA/THK CAL BLOCKS  COMMENTS Nozzle Inside Radius Section B03.140.001        2SGA-INLET            MCM 2201.01-0207      NDE-680      UT        CS        0.000  50235 STEAM GENERATOR 2A INLET NOZZLE TO Circumferential      NC MCM 2201.01-0216                                          6.500        LOWER HEAD. Y1-X2 QUADRANT. (INSIDE Class A                                                                Nozzle to                          RADIUS SECTION).
CATEGORY B-D, Full Penetration Welded                      INSERVICE INSPECTION PLAN MANAGEMENT Nozzels In Vessels - Inspection Program B                Inservice Inspection Database Management System                                    Plan Report Steam Generators (Primary Side)                                        McGuire 2                                                          Page 1 Inservice Inspection Plan for Interval 3 Outage 1                                05/25/2005 ITEM NUMBER            ID NUMBER  SYS ISO/DWG 3NUMBERS        PROC      INSP REQ MAT/SCH DIA/THK CAL BLOCKS  COMMENTS Nozzle Inside Radius Section B03.140.001        2SGA-INLET            MCM 2201.01-0207      NDE-680      UT        CS        0.000  50235 STEAM GENERATOR 2A INLET NOZZLE TO Circumferential      NC MCM 2201.01-0216                                          6.500        LOWER HEAD. Y1-X2 QUADRANT. (INSIDE Class A                                                                Nozzle to                          RADIUS SECTION).
Head B03.140.002        2SGA-OUTLET            MCM 2201.01-0207      NDE-680      UT        CS        0.000  50235 STEAM GENERATOR 2A OUTLET NOZZLE TO Circumferential      NC  MCM 2201.01-0216                                        6.500        LOWER HEAD. Y2-X2 QUADRANT. (INSIDE Class A                                                                Nozzle to                          RADIUS SECTION).
Head B03.140.002        2SGA-OUTLET            MCM 2201.01-0207      NDE-680      UT        CS        0.000  50235 STEAM GENERATOR 2A OUTLET NOZZLE TO Circumferential      NC  MCM 2201.01-0216                                        6.500        LOWER HEAD. Y2-X2 QUADRANT. (INSIDE Class A                                                                Nozzle to                          RADIUS SECTION).
Head
Head Total B03.140 Items:        2 Total B03 Items:            2
-
Total B03.140 Items:        2 Total B03 Items:            2


EOC 16      C                                                        C DUKE ENERGY CORPORATION
EOC 16      C                                                        C DUKE ENERGY CORPORATION
Line 174: Line 170:


EOC    16  C
EOC    16  C
             --        .DUKE                                      ENERGY CORPORATION
             --        .DUKE                                      ENERGY CORPORATION CATEGORY B-G-1, Pressure Retaining Bioting,          INSERVICE INSPECTION PLAN MANAGEMENT Greater Than 2 In. In Diameter                    Inservice Inspection Database Management System                                  Plan Report Reactor Vessel                                                      McGuire 2                                                          Page 4 Inservice Inspection Plan for Interval 3 Outage 1                                05/25/2005 ITEM NUMBER          ID NUMBER SYS ISOIDWG NUME 3ERS      PROC      INSP REQ MAT/SCH DIArHK CAL BLOCKS    COMMENTS
                                                                                                                                .
CATEGORY B-G-1, Pressure Retaining Bioting,          INSERVICE INSPECTION PLAN MANAGEMENT Greater Than 2 In. In Diameter                    Inservice Inspection Database Management System                                  Plan Report Reactor Vessel                                                      McGuire 2                                                          Page 4 Inservice Inspection Plan for Interval 3 Outage 1                                05/25/2005 ITEM NUMBER          ID NUMBER SYS ISOIDWG NUME 3ERS      PROC      INSP REQ MAT/SCH DIArHK CAL BLOCKS    COMMENTS
  ** Closure Studs, when removed 806.030.001    2RPV-664-31-01      MCM2201.01-01          PDI-UT-5      UT        Cs      7.000  50501 REACTOR VESSEL CLOSURE HEAD STUD.
  ** Closure Studs, when removed 806.030.001    2RPV-664-31-01      MCM2201.01-01          PDI-UT-5      UT        Cs      7.000  50501 REACTOR VESSEL CLOSURE HEAD STUD.
NC  MCM 2201.01-0106                                        64.560 Class A B06.030.002    2RPV-664-31-02      MCM2201.01-01          PDI-UT-5      UT        CS      7.000  50501 REACTOR VESSEL CLOSURE HEAD STUD.
NC  MCM 2201.01-0106                                        64.560 Class A B06.030.002    2RPV-664-31-02      MCM2201.01-01          PDI-UT-5      UT        CS      7.000  50501 REACTOR VESSEL CLOSURE HEAD STUD.
Line 192: Line 186:


EOC 16      C                                                                (I-.-
EOC 16      C                                                                (I-.-
DUKE ENERGY CORPORATION
DUKE ENERGY CORPORATION CATEGORY B-G-1. Pressure Retaining Boltinq. INSERVICE INSPECTION PLAN MANAGEMENT Greater Than 2 in. In Diameter                          Inservice Inspection Database Management System                                  Plan Report WReactor Vessel                                                            McGuire 2                                                        Page 6 Inservice Inspection Plan for Interval 3 Outage 1                              05/25/2005 ITEM NUMBER        ID NUMBER        SYS ISO/DWG NUMBERS        PROC      INSP REQ MAT/SCH DIA/THK CAL BLOCKS  COMMENTS Closure Washers, Bushings ----
                                                                                                                                    .
CATEGORY B-G-1. Pressure Retaining Boltinq. INSERVICE INSPECTION PLAN MANAGEMENT Greater Than 2 in. In Diameter                          Inservice Inspection Database Management System                                  Plan Report WReactor Vessel                                                            McGuire 2                                                        Page 6 Inservice Inspection Plan for Interval 3 Outage 1                              05/25/2005 ITEM NUMBER        ID NUMBER        SYS ISO/DWG NUMBERS        PROC      INSP REQ MAT/SCH DIA/THK CAL BLOCKS  COMMENTS Closure Washers, Bushings ----
806.050.001  2RPV-664-33-01            MCM2201.01-01          QAL-13        VT-1      CS      10.560        REACTOR VESSEL CLOSURE HEAD WASHER.
806.050.001  2RPV-664-33-01            MCM2201.01-01          QAL-13        VT-1      CS      10.560        REACTOR VESSEL CLOSURE HEAD WASHER.
NC MCM 2201.01-0106                                          1.719 Class A 806.050.002  2RPV-664-33-02            MCM 2201.01-01        QAL-13        VT-1      CS      10.560        REACTOR VESSEL CLOSURE HEAD WASHER.
NC MCM 2201.01-0106                                          1.719 Class A 806.050.002  2RPV-664-33-02            MCM 2201.01-01        QAL-13        VT-1      CS      10.560        REACTOR VESSEL CLOSURE HEAD WASHER.
Line 238: Line 230:


EOC 16      IC DUKE ENERGY CORPORATION C
EOC 16      IC DUKE ENERGY CORPORATION C
CATEGORY B-M-2. Valve Body                                INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System                                    Plan Report McGuire 2                                                          Page 12 Inservice Inspection Plan for Interval 3 Outage 1                                05/2512005 ITEM NUMBER
CATEGORY B-M-2. Valve Body                                INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System                                    Plan Report McGuire 2                                                          Page 12 Inservice Inspection Plan for Interval 3 Outage 1                                05/2512005 ITEM NUMBER IDNUMBER SYS ISO/DWG NUMBERS        PROC      INSP REQ MATISCH DIANTHK CAL BLOCKS  COMMENTS Valve Body, Exceeding NPS 4
_ . _  _ _
IDNUMBER
_  _ _
SYS ISO/DWG NUMBERS        PROC      INSP REQ MATISCH DIANTHK CAL BLOCKS  COMMENTS Valve Body, Exceeding NPS 4
* B12.050.001C 2NC-3                      MCFI-2NC53            OAL-14        VT-3      Ss        6.000        6 CROSBYRELIEFVALVE. INSPECT ONE OF NC MC-ISIN3-2553-02.00                                      0.000        THE FOLLOWING VALVES: 2NC-1, 2NC-2, OR Class A                              MCM 1205.09-0001                                                      2NC-3 ONLY IFVALVE ISDISASSEMBLED FOR MAINTENANCE, REPAIR, OR VOLUMETRIC EXAMINATION.
* B12.050.001C 2NC-3                      MCFI-2NC53            OAL-14        VT-3      Ss        6.000        6 CROSBYRELIEFVALVE. INSPECT ONE OF NC MC-ISIN3-2553-02.00                                      0.000        THE FOLLOWING VALVES: 2NC-1, 2NC-2, OR Class A                              MCM 1205.09-0001                                                      2NC-3 ONLY IFVALVE ISDISASSEMBLED FOR MAINTENANCE, REPAIR, OR VOLUMETRIC EXAMINATION.
Total B12.050 Items:      1 I Total B12 Items:          I
Total B12.050 Items:      1 I Total B12 Items:          I
Line 292: Line 280:
Welded Attachments      **-*
Welded Attachments      **-*
C03.020.024    2MCA-ND-5311          MCSRD-2FW-350/sht. 4 NDE-35          PT        SS        12.000      WELDED ATTACHMENT. INSPECT WITH Mech Snubber        ND  MC-ISIN3-2561-01.00                                      0.375      F01.020.103C.
C03.020.024    2MCA-ND-5311          MCSRD-2FW-350/sht. 4 NDE-35          PT        SS        12.000      WELDED ATTACHMENT. INSPECT WITH Mech Snubber        ND  MC-ISIN3-2561-01.00                                      0.375      F01.020.103C.
Class B                            2MCA-ND-5311
Class B                            2MCA-ND-5311 Total C03.020 Items:      1 Total C03 Items:          3 I
-
Total C03.020 Items:      1 Total C03 Items:          3 I


EOC 16      C DUKE ENERGY CORPORATION
EOC 16      C DUKE ENERGY CORPORATION
(
(
CATEGORY C-G. Pressure Retalninq Welds In              INSERVICE INSPECTION PLAN MANAGEMENT Pumps And Valves                                    Inservice Inspection Database Management System                                      Plan Report McGuire 2                                                            Page 20 Inservice Inspection Plan for Interval 3 Outage 1                                    05/25/2005 ITEM NUMBER            ID NUMBER SYS ISO/DWG NUWABERS        PROC      INSP REQ MATISCH DIArTHK CAL BLOCKS  COMMENTS IValve BodvWelds C06.020.003A 2NV0804-1              MCM 1205.00-0362        NDE-35        PT          SS      4.000        ITEM # 9J-226. INSPECT ONE VALVE INTHIS Circumferential    NV  MC-ISIN3-2554-03.01                                      0.878        GROUP (3A-3C) PER INTERVAL.
CATEGORY C-G. Pressure Retalninq Welds In              INSERVICE INSPECTION PLAN MANAGEMENT Pumps And Valves                                    Inservice Inspection Database Management System                                      Plan Report McGuire 2                                                            Page 20 Inservice Inspection Plan for Interval 3 Outage 1                                    05/25/2005 ITEM NUMBER            ID NUMBER SYS ISO/DWG NUWABERS        PROC      INSP REQ MATISCH DIArTHK CAL BLOCKS  COMMENTS IValve BodvWelds C06.020.003A 2NV0804-1              MCM 1205.00-0362        NDE-35        PT          SS      4.000        ITEM # 9J-226. INSPECT ONE VALVE INTHIS Circumferential    NV  MC-ISIN3-2554-03.01                                      0.878        GROUP (3A-3C) PER INTERVAL.
Class B                                                              Valve Body to Valve Body C06.020.005A 2ND0030A-1              MCM 1205.00-0455        NDE-35        PT          SS      8.000        ITEM # 9D-227. INSPECT ONE VALVE INTHIS Circumferential    ND MC-ISIN3-2561-01.00                                        0.722        GROUP (5A-only valve) PER INTERVAL Class B                                                              Valve Body to Valve Body
Class B                                                              Valve Body to Valve Body C06.020.005A 2ND0030A-1              MCM 1205.00-0455        NDE-35        PT          SS      8.000        ITEM # 9D-227. INSPECT ONE VALVE INTHIS Circumferential    ND MC-ISIN3-2561-01.00                                        0.722        GROUP (5A-only valve) PER INTERVAL Class B                                                              Valve Body to Valve Body Total COS.020 Items:        2 Total COS Items:            2
-
Total COS.020 Items:        2 Total COS Items:            2


EOC 16 DUKE ENERGY CORPORATION (3
EOC 16 DUKE ENERGY CORPORATION (3
Line 310: Line 294:
D01.010.004 2KFHX-SUPPORT-2A          MCM 1201.06-0027        QAL-13        VT-1      NA        0.000        FUEL POOL COOLING HX 2A SUPPORT.
D01.010.004 2KFHX-SUPPORT-2A          MCM 1201.06-0027        QAL-13        VT-1      NA        0.000        FUEL POOL COOLING HX 2A SUPPORT.
Rigid Restraint    KF  MC-ISIN3-2570-01.01                                      0.250        WELDED ATTACHMENT.
Rigid Restraint    KF  MC-ISIN3-2570-01.01                                      0.250        WELDED ATTACHMENT.
Class C                          MC-1220-32
Class C                          MC-1220-32 Total D01.010 Items:        1 Total D01 Items:            I
-
Total D01.010 Items:        1 Total D01 Items:            I


EOC 16      C                                                                C,'
EOC 16      C                                                                C,'
Line 365: Line 347:
Class C F01.040.038B 2ELDHX-SUPPORT              MCM 1201.06-0010        QAL-14        VT-3      NA        0.000        EXCESS LETDOWN HX SUPPORT.
Class C F01.040.038B 2ELDHX-SUPPORT              MCM 1201.06-0010        QAL-14        VT-3      NA        0.000        EXCESS LETDOWN HX SUPPORT.
Rigid Restraint    NV  MC-ISIN3-2554-01.02                                      0.375 Class B F01.040.039B      2NSHX-SUPPORT-2B        MCM 1201.06-0090        QAL-14        VT-3      NA        0.000        CONTAINMENT SPRAY HX 2B SUPPORT. SINCE Rigid Restraint    NS  MC-ISIN3-2563-01.00                                      0.750        *HX A' & 'HX B ARE OF DIFFERENT DESIGN Class B                              MC 1220-32                                                            WILL EXAMINE BOTH.
Rigid Restraint    NV  MC-ISIN3-2554-01.02                                      0.375 Class B F01.040.039B      2NSHX-SUPPORT-2B        MCM 1201.06-0090        QAL-14        VT-3      NA        0.000        CONTAINMENT SPRAY HX 2B SUPPORT. SINCE Rigid Restraint    NS  MC-ISIN3-2563-01.00                                      0.750        *HX A' & 'HX B ARE OF DIFFERENT DESIGN Class B                              MC 1220-32                                                            WILL EXAMINE BOTH.
-
Total F01.040 items:        7 Total F01 Items:            74
Total F01.040 items:        7 Total F01 Items:            74


Line 387: Line 368:
Class B                                                      See Comm    Reducer to                          DEPENDING UPON THE EXAMINERS Pipe                                QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY BE USED IN LIEU OF PROCEDURE NDE-600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.
Class B                                                      See Comm    Reducer to                          DEPENDING UPON THE EXAMINERS Pipe                                QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY BE USED IN LIEU OF PROCEDURE NDE-600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.


EOC 16    C DUKE ENERGY CORPORATION
EOC 16    C DUKE ENERGY CORPORATION CATEGORY R-A. Risk Informed Piping                      INSERVICE INSPECTION PLAN MANAGEMENT Examinations                                        InservIce Inspection Database Management System                                        Plan Report
                                                                                                                                        .
CATEGORY R-A. Risk Informed Piping                      INSERVICE INSPECTION PLAN MANAGEMENT Examinations                                        InservIce Inspection Database Management System                                        Plan Report
.Class    1 and 2 Piping Welds                                            McGuire 2                                                              Page 34 Inservice Inspection Plan for Interval 3 Outage 1                                    05/25/2005 ITEM NUMBER          ID NUMBER SYS ISOIDWG NUMBERS          PROC      INSP REQ MATISCH DIAITHK CAL BLOCKS    COMMENTS R01.011.051    2NDP73-1              MCFI-2ND7              NDE-600      UT        SS        8.000 See Comm SEGMENT ND-008A. *SEE SECTION 8 FOR Circumferential    ND MC-ISIN-2561-01.00      PDI-UT-2                          0.250          CALIBRATION BLOCK REQUIREMENTS.
.Class    1 and 2 Piping Welds                                            McGuire 2                                                              Page 34 Inservice Inspection Plan for Interval 3 Outage 1                                    05/25/2005 ITEM NUMBER          ID NUMBER SYS ISOIDWG NUMBERS          PROC      INSP REQ MATISCH DIAITHK CAL BLOCKS    COMMENTS R01.011.051    2NDP73-1              MCFI-2ND7              NDE-600      UT        SS        8.000 See Comm SEGMENT ND-008A. *SEE SECTION 8 FOR Circumferential    ND MC-ISIN-2561-01.00      PDI-UT-2                          0.250          CALIBRATION BLOCK REQUIREMENTS.
Class B                                                  See Comm Elbow to                                DEPENDING UPON THE EXAMINERS Pipe                                  QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY BE USED IN LIEU OF PROCEDURE NDE-600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.
Class B                                                  See Comm Elbow to                                DEPENDING UPON THE EXAMINERS Pipe                                  QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY BE USED IN LIEU OF PROCEDURE NDE-600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.
Line 451: Line 430:


DUKE ENErK        )RPORATION QUALITY ASSURAIC TECHNICAL SERVICES          (
DUKE ENErK        )RPORATION QUALITY ASSURAIC TECHNICAL SERVICES          (
In-Service Inspection Database Management Syitem        Run D EOC 16                                                                                                  Page 4 McGuire 2 Inservice Inspection Listing Plant: McGuire 2                                                                                    05/2512005 Interval 3 Outage 1 ITEM NUMBER
In-Service Inspection Database Management Syitem        Run D EOC 16                                                                                                  Page 4 McGuire 2 Inservice Inspection Listing Plant: McGuire 2                                                                                    05/2512005 Interval 3 Outage 1 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS F01.020.503C    2MCR-VO-4507      Va    03/04/2005      CLR                        N      N F01.020.505B    2MCR-VQ-4544      Va    03/04/2005      CLR                        N      N F01.020.525B    2MCR.WL-4061      WL    03/04/2005      CLR                        N      N F01.030.001 B    2MCA-CA-5160      CA    02/08/2005      CLR                        N      N F01.030.002A    2MCA-CA-5210      CA    02/08/2005      CLR                        N      N F01.030.003A    2MCA-CA-5208      CA    02/08/2005      CLR                        N      N F01.030.004A    2MCA-CA-5554      CA    02/08/2005      CLR                        N      N F01.030.050A    2MCR-KC-4022      KC    03/05/2005      CLR                        N      N F01.030.051C    2MCR-KC-4557      KC    03/05/2005      CLR                        N      N F01.030.052A    2MCR-KC-4054      KC    03/05/2005      CLR                        N      N F01.030.053A    2MCR-KC-4057      KC    03/05/2005      CLR                        N      N F01.030.054B    2MCR-KC-4503      KC    03/05/2005      CLR                        N      N F01.030.055A    2MCA-KC-3327      KC    02/10/2005      CLR                        N      N F01.030.056A    2MCA-KC-3328      KC    02110/2005      CLR                        N      N F01.030.061A    2MCA-KC-3285      KC    02/10/2005      CLR                        N      N F01.030.1111B    2-MCA-LD-3071      LD    02/01/2005      CLR                        N      N F01.030.112A    2-MCA-LD-3079      LD    02/01/2005      CLR                        N      N F01.030.113C    2-MCA-LD-3010      LD    02101/2005      CLR                        N      N F01.030.191 B    2MCA-RV-H503      RV    02/0212005      CLR                        N      N F01.040.002B    2PZR-LUGS          NC    03/10/2005      CLR                        N      N F01.040.008B    2NSP-SUPPORT-2A    NS    02/01/2005      CLR                        N      N F01.040.009B    2NSHX-SUPPORT-2A  NS    02101/2005      CLR                        N      N F01.040.01 OB    2REGHX-SUPPORT    NV    03/11/2005      CLR                        N.      N F01.040.034B    2DG-SUPPORT-2A    KD    02/01/2005      CLR                        N      N F01.040.038B    2ELDHX.SUPPORT    NV    03/10/2005      CLR                        N      N F01.040.039B    2NSHX-SUPPORT-2B  NS    02/01/2005      CLR                        N      N G03.001.001      2NC2FW16-1        NC    03/10/2005      CLR                        N      N G03.001.001A    2NC2FW16-1        NC    03/10/2005      CLR                        N      N R01.011.013      2NC2F2-8C          NC    03/2212005      CLR          87.00%        N      Y R01.011.019      2NC2FW22-3        NC    03/13/2005      CLR                        N      N R01.011.020      2NC2FW22-16        NC    03/2212005      CLR                        N      N R101.011.021    2NC2FW24-6        NC    03/13/2005      CLR          90.80%        N      N R01.011.026      2NC2FW31-8        NC    02/25/2005      CLR                        N      N R01.011.051      2NDP73-1          ND    02/25/2005      CLR                        N      N R01.011.052      2ND2FW15-3        ND    02/25/2005      CLR                        N      N R01.011.061      2NIP23-1          NI    02121/2005      CLR                        N      N
_        _ _
ID NUMBER
_    .
SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS F01.020.503C    2MCR-VO-4507      Va    03/04/2005      CLR                        N      N F01.020.505B    2MCR-VQ-4544      Va    03/04/2005      CLR                        N      N F01.020.525B    2MCR.WL-4061      WL    03/04/2005      CLR                        N      N F01.030.001 B    2MCA-CA-5160      CA    02/08/2005      CLR                        N      N F01.030.002A    2MCA-CA-5210      CA    02/08/2005      CLR                        N      N F01.030.003A    2MCA-CA-5208      CA    02/08/2005      CLR                        N      N F01.030.004A    2MCA-CA-5554      CA    02/08/2005      CLR                        N      N F01.030.050A    2MCR-KC-4022      KC    03/05/2005      CLR                        N      N F01.030.051C    2MCR-KC-4557      KC    03/05/2005      CLR                        N      N F01.030.052A    2MCR-KC-4054      KC    03/05/2005      CLR                        N      N F01.030.053A    2MCR-KC-4057      KC    03/05/2005      CLR                        N      N F01.030.054B    2MCR-KC-4503      KC    03/05/2005      CLR                        N      N F01.030.055A    2MCA-KC-3327      KC    02/10/2005      CLR                        N      N F01.030.056A    2MCA-KC-3328      KC    02110/2005      CLR                        N      N F01.030.061A    2MCA-KC-3285      KC    02/10/2005      CLR                        N      N F01.030.1111B    2-MCA-LD-3071      LD    02/01/2005      CLR                        N      N F01.030.112A    2-MCA-LD-3079      LD    02/01/2005      CLR                        N      N F01.030.113C    2-MCA-LD-3010      LD    02101/2005      CLR                        N      N F01.030.191 B    2MCA-RV-H503      RV    02/0212005      CLR                        N      N F01.040.002B    2PZR-LUGS          NC    03/10/2005      CLR                        N      N F01.040.008B    2NSP-SUPPORT-2A    NS    02/01/2005      CLR                        N      N F01.040.009B    2NSHX-SUPPORT-2A  NS    02101/2005      CLR                        N      N F01.040.01 OB    2REGHX-SUPPORT    NV    03/11/2005      CLR                        N.      N F01.040.034B    2DG-SUPPORT-2A    KD    02/01/2005      CLR                        N      N F01.040.038B    2ELDHX.SUPPORT    NV    03/10/2005      CLR                        N      N F01.040.039B    2NSHX-SUPPORT-2B  NS    02/01/2005      CLR                        N      N G03.001.001      2NC2FW16-1        NC    03/10/2005      CLR                        N      N G03.001.001A    2NC2FW16-1        NC    03/10/2005      CLR                        N      N R01.011.013      2NC2F2-8C          NC    03/2212005      CLR          87.00%        N      Y R01.011.019      2NC2FW22-3        NC    03/13/2005      CLR                        N      N R01.011.020      2NC2FW22-16        NC    03/2212005      CLR                        N      N R101.011.021    2NC2FW24-6        NC    03/13/2005      CLR          90.80%        N      N R01.011.026      2NC2FW31-8        NC    02/25/2005      CLR                        N      N R01.011.051      2NDP73-1          ND    02/25/2005      CLR                        N      N R01.011.052      2ND2FW15-3        ND    02/25/2005      CLR                        N      N R01.011.061      2NIP23-1          NI    02121/2005      CLR                        N      N


DUKE ENEr T)RPORATION QUALITY ASSURANV= TECHNICAL SERVICES In-Service Inspection Database Management System    Run D EOC 16                                                                                            Page 5 McGuire 2 Inservice Inspection Listing Plant: McGuire 2                                              Interval 3 Outage 1              05/25/2005 ITEM NUMBER      ID NUMBER    SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS R01.011.063      2N12F608      NI    02/25/2005      CLR              .--        N      N R01.011.064      2NI2F611      NI    02/25/2005      CLR                        N      N R101.011.065    2N12F616      NI    02/25/2005      CLR              -          N      N R01.011.066      2N12F619      NI    02/25/2005      CLR              -          N      N R01.011.067      2NI2F234      NI    02124/2005      CLR              -          N      N R01.011.068      2NIP59-2      NI    02/24/2005      CLR              -          N      N R01.011.069      2NI2FW27-13    NI    03/22/2005      CLR          89.80%        N      Y R01.011.070      2NI2FW27-24    NI    03/22/2005      CLR              ---        N      N R01.011.071      2NI2FW27-15    NI    03/22/2005      CLR          89.80%        N      Y R101.011.130    2NV2FW180-48  NV    02/21/2005      CLR              -          N      N R101.013.001    2RV2FW30-17    RV    02/25/2005      CLR              -        N      N
DUKE ENEr T)RPORATION QUALITY ASSURANV= TECHNICAL SERVICES In-Service Inspection Database Management System    Run D EOC 16                                                                                            Page 5 McGuire 2 Inservice Inspection Listing Plant: McGuire 2                                              Interval 3 Outage 1              05/25/2005 ITEM NUMBER      ID NUMBER    SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS R01.011.063      2N12F608      NI    02/25/2005      CLR              .--        N      N R01.011.064      2NI2F611      NI    02/25/2005      CLR                        N      N R101.011.065    2N12F616      NI    02/25/2005      CLR              -          N      N R01.011.066      2N12F619      NI    02/25/2005      CLR              -          N      N R01.011.067      2NI2F234      NI    02124/2005      CLR              -          N      N R01.011.068      2NIP59-2      NI    02/24/2005      CLR              -          N      N R01.011.069      2NI2FW27-13    NI    03/22/2005      CLR          89.80%        N      Y R01.011.070      2NI2FW27-24    NI    03/22/2005      CLR              ---        N      N R01.011.071      2NI2FW27-15    NI    03/22/2005      CLR          89.80%        N      Y R101.011.130    2NV2FW180-48  NV    02/21/2005      CLR              -          N      N R101.013.001    2RV2FW30-17    RV    02/25/2005      CLR              -        N      N
Line 526: Line 501:
                                                     .                                                                                            I II                                                                                                I I                                                      I fb) Forgings rY-ntP.        .. ...                            F316                                  McWilliamrs [or__                                    _    _
                                                     .                                                                                            I II                                                                                                I I                                                      I fb) Forgings rY-ntP.        .. ...                            F316                                  McWilliamrs [or__                                    _    _
F.A1 05I9J Svf        S                                                  11 intr2s rorQ.e                      .            -
F.A1 05I9J Svf        S                                                  11 intr2s rorQ.e                      .            -
                                                                                                      ..                                  .
I        _    _    _    _  _        _I_                                        .                                                    I all
I        _    _    _    _  _        _I_                                        .                                                    I all
  ,-,  Itr    mant 9..~ hJ rtt
  ,-,  Itr    mant 9..~ hJ rtt
Line 572: Line 546:
: 8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. El Other 0 Exempto Pressure          . -      psig      Test Temp.                  OF Pressure                    psig      Test Temp.                  OF Pressure                  psig      Test Temp.                  OF
: 8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. El Other 0 Exempto Pressure          . -      psig      Test Temp.                  OF Pressure                    psig      Test Temp.                  OF Pressure                  psig      Test Temp.                  OF
: 9. Remarks Test performed per task 9 of this work order (visual)
: 9. Remarks Test performed per task 9 of this work order (visual)
                                                                              .
                                                                                                                              ''
(Applicable Manufacturers Data Records to be attached)
(Applicable Manufacturers Data Records to be attached)
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.
Line 601: Line 573:
                             .__    _      .-          .        .      .      -      .      .      .          -      .    ;    -:          ;          _0              Replacement              0 Yes E.                                                                                                                                                                    0 Repaired,                0 No
                             .__    _      .-          .        .      .      -      .      .      .          -      .    ;    -:          ;          _0              Replacement              0 Yes E.                                                                                                                                                                    0 Repaired,                0 No
                                                               ..                                          .                                                            OReplaced,
                                                               ..                                          .                                                            OReplaced,
          ;_        -      .
__      :.      --            .      .                                                                                                  0 Replacement              0 Yes F                                                        .                        .                                                        .                          0. Repaired,                0 No..
__      :.      --            .      .                                                                                                  0 Replacement              0 Yes F                                                        .                        .                                                        .                          0. Repaired,                0 No..
0- Replaced,
0- Replaced,
Line 612: Line 583:
Pressure                    psig    Test Temp.                    OF Pressure                    psig      Test Temp.                  OF Pressure                    psig    Test Temp.                    OF
Pressure                    psig    Test Temp.                    OF Pressure                    psig      Test Temp.                  OF Pressure                    psig    Test Temp.                    OF
: 9. Remarks (Applicable Manufacturers Data Records to be attached)
: 9. Remarks (Applicable Manufacturers Data Records to be attached)
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl' Type Code Symbol Stamp N/A Certificate of Authorization No. N/A                              Expiration Date N/A Slgned                      F.R. Sorrow. QA Tech Support              Date 04/08, 2005 Owner or Owner's Designee, Title
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl' Type Code Symbol Stamp N/A Certificate of Authorization No. N/A                              Expiration Date N/A Slgned                      F.R. Sorrow. QA Tech Support              Date 04/08, 2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION                          .
                                    ;    .          .                              .
CERTIFICATE OF INSERVICE INSPECTION                          .
1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period 3Z ?1 Sto 4/9/0os : and state that to the best of my knowledge and belief, the Owner has performed e iamnations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.
1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period 3Z ?1 Sto 4/9/0os : and state that to the best of my knowledge and belief, the Owner has performed e iamnations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for.
Line 631: Line 600:
: 6. Identification of Components RePaired or Replaced and Replacement Coi                      onents:
: 6. Identification of Components RePaired or Replaced and Replacement Coi                      onents:
Column 1                                        Column 2              . Column 3'                Column 4                  Column 5-          Col 6          Column 7                    Column 8 Name of Component    -                .        Name of Mfg            Mtg Seral No.          National Board No.        Other Idenification Year Built  Repaired, Replaced, or ASME Code Stamped
Column 1                                        Column 2              . Column 3'                Column 4                  Column 5-          Col 6          Column 7                    Column 8 Name of Component    -                .        Name of Mfg            Mtg Seral No.          National Board No.        Other Idenification Year Built  Repaired, Replaced, or ASME Code Stamped
        .___
____  ____  :_____                    .__..                      ___                                                                                  Replacement                  (yes or no)
____  ____  :_____                    .__..                      ___                                                                                  Replacement                  (yes or no)
A                                                .                                                                                                            0 Repaired,                  0 No RN Piping    -                        Duke Power                    N/A                      60                      N/A            1982      3 Replaced,
A                                                .                                                                                                            0 Repaired,                  0 No RN Piping    -                        Duke Power                    N/A                      60                      N/A            1982      3 Replaced,
Line 660: Line 628:


FORM NIS-2 OWNER'S                ijRT FOR REPAIRS OR REPLACEMENTS                                                                C As Required By The Provisions Of The ASME Code Section Xi
FORM NIS-2 OWNER'S                ijRT FOR REPAIRS OR REPLACEMENTS                                                                C As Required By The Provisions Of The ASME Code Section Xi
: 1. Owner Address:            Duke Power Comoanv                                                                                                                    1-        1a. Date 03/30/2005
: 1. Owner Address:            Duke Power Comoanv                                                                                                                    1-        1a. Date 03/30/2005 Mcj o.
        .  .      .
                    -  ..
                            .
Mcj o.
ul %Nucla          Stato
ul %Nucla          Stato
                                                             ..            Kr' hnO3n003fl4AM V
                                                             ..            Kr' hnO3n003fl4AM V
Line 674: Line 638:
: 6. Identification of Components Repaired or Replaced and Replacement Com zonents:                                                                                                                        -
: 6. Identification of Components Repaired or Replaced and Replacement Com zonents:                                                                                                                        -
Column 1                                Column 2                .          Column 3                  Column 4                Column 5                Col 6          Column 7                  Column 8 Name of Component                        Name of Mfg                        M Serial No.            National Board No.      Other Identification    Year Built  Repaired, Replaced, or ASME Code Stamped
Column 1                                Column 2                .          Column 3                  Column 4                Column 5                Col 6          Column 7                  Column 8 Name of Component                        Name of Mfg                        M Serial No.            National Board No.      Other Identification    Year Built  Repaired, Replaced, or ASME Code Stamped
___ __ __ ___
___    __
__ _____
___    _    __  ___                __    ___  __  __  __  __  ___    __  __Replacem                      ent              (yes or no)
___    _    __  ___                __    ___  __  __  __  __  ___    __  __Replacem                      ent              (yes or no)
A                                  :E                                                                                                                                  Repaired,                0 No RV Piping                    Duke Power                                N/A                      72                    N/A;                  1982 0 Replaced,-
A                                  :E                                                                                                                                  Repaired,                0 No RV Piping                    Duke Power                                N/A                      72                    N/A;                  1982 0 Replaced,-
                                                                                                           .    .  . .- , -.,              *        .        *. OReplacement                iWaYes B                                                                                                                                                        .    . 0 Repaired,                  0 No O. Replaced,-
                                                                                                           .    .  . .- , -.,              *        .        *. OReplacement                iWaYes B                                                                                                                                                        .    . 0 Repaired,                  0 No O. Replaced,-
                            .___  ___    .____
____ ______                      .                                                                                              Replacement              0 Yes C                                                                                                                                                                    0  Repaired,                0 No 0 Replaced,:
____ ______                      .                                                                                              Replacement              0 Yes C                                                                                                                                                                    0  Repaired,                0 No 0 Replaced,:
________              .        :      .
_.__'_'_.                                                                ..                                              0 Replacement                  0Yes D                                                                                                                                                                    0 Repaired,                  O No 0 Replaced,
_.__'_'_.                                                                ..                                              0 Replacement                  0Yes D                                                                                                                                                                    0 Repaired,                  O No 0 Replaced,
:____3 . .Replacement                                                                                                                                                                  O Yes E                                                                                                                                                                    0 Repaired,                  0 No 0 Replaced.
:____3 . .Replacement                                                                                                                                                                  O Yes E                                                                                                                                                                    0 Repaired,                  0 No 0 Replaced.
Line 707: Line 666:
.1. Owner Address:        Duke Power Comoanv                                                                                                                                          1a. Date 04106/2005                  :
.1. Owner Address:        Duke Power Comoanv                                                                                                                                          1a. Date 04106/2005                  :
             -    -    I.-  M-ut  lr (Ih In^h  %trfrnMt ehar c...a St ato. -  .u ttg%:Nr
             -    -    I.-  M-ut  lr (Ih In^h  %trfrnMt ehar c...a St ato. -  .u ttg%:Nr
                                                                        *
                                                                           %nJa Paq1n.i
                                                                           %nJa
                                                                            - -
Paq1n.i
                                                                                       * -n vvv A!    4 Sheet        1 of 1
                                                                                       * -n vvv A!    4 Sheet        1 of 1
: 2. Plant Address:        McGuire Nucleatr Statlon -                -
: 2. Plant Address:        McGuire Nucleatr Statlon -                -
Line 731: Line 687:
                         -_3                                -      ,. _        :                  - -:-0                                                                      Replacement                0Yes Page I of 2 Revision 7
                         -_3                                -      ,. _        :                  - -:-0                                                                      Replacement                0Yes Page I of 2 Revision 7


                                                                                                                                  .
Form NIS-2 (Back)
Form NIS-2 (Back)
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
Line 797: Line 752:
                                                           -._O0
                                                           -._O0
                                                             .-                                                                                              Replacement                0Yes F                .3.              ..                                                                                                                      0 Repaired,                  0 No 0 Replaced,
                                                             .-                                                                                              Replacement                0Yes F                .3.              ..                                                                                                                      0 Repaired,                  0 No 0 Replaced,
          ._              ..    . .          .. . .            ..
_  .                      .  .            ...                                            0 Replacement                0 Yes Page 1 of 2 Revision 7
_  .                      .  .            ...                                            0 Replacement                0 Yes Page 1 of 2 Revision 7


Line 853: Line 807:
: 6. Identification of Componrints Repaired or Replaced and Replacement Coin onents:-
: 6. Identification of Componrints Repaired or Replaced and Replacement Coin onents:-
Column 1                          Column 2                    Column 3                      Column 4                Column 5        -Col 6          Column 7                Column 8 Name of Component                  Name of Mfg                Mfg Serial No.            National Board No.        Ote Identification Year Built  Repaired, Replaced, or ASME Code Stamped
Column 1                          Column 2                    Column 3                      Column 4                Column 5        -Col 6          Column 7                Column 8 Name of Component                  Name of Mfg                Mfg Serial No.            National Board No.        Ote Identification Year Built  Repaired, Replaced, or ASME Code Stamped
_ _ _  _  _ _ _  _ _ _ _ _ _ __  __
_ _ _ _ _ _ _    _ _ _  _ _    _ _ _ _  _ _R                                      eplacem ent              ( me or no)
_ _ _ _ _ _ _    _ _ _  _ _    _ _ _ _  _ _R                                      eplacem ent              ( me or no)
A            v                                  -                                                                      .El  N/                          Repaired,            O No            -
A            v                                  -                                                                      .El  N/                          Repaired,            O No            -
Line 888: Line 841:
__    . _ ,, _  _    _  .,_ :.    .  .,..,                            _      _ .-_      _  __  ,        ,Instaled                                      (ves or no)
__    . _ ,, _  _    _  .,_ :.    .  .,..,                            _      _ .-_      _  __  ,        ,Instaled                                      (ves or no)
A                              -          .                          ..                                                                                          0 Repaired,            O      No 2-BB-VA-2                      Borg - Warner                          9088                      104                      N/A          -      1976 .      Replaced,:.
A                              -          .                          ..                                                                                          0 Repaired,            O      No 2-BB-VA-2                      Borg - Warner                          9088                      104                      N/A          -      1976 .      Replaced,:.
                                          .__
                                             .__          .__            ._              ._      ..                      ...                                  . 0  Replacement            El Yes B                                                                                                                                                                0 Repaired,                0 No 2-BB-VA-2                          BW IP          -            E496P-1-2        .            2224                      N/A                  1999    0 Replaced, l Replacement            El Yes-C                          .                                                                                                                                      0 Repaired,                  0 No 0 Replaced;
                                             .__          .__            ._              ._      ..                      ...                                  . 0  Replacement            El Yes B                                                                                                                                                                0 Repaired,                0 No 2-BB-VA-2                          BW IP          -            E496P-1-2        .            2224                      N/A                  1999    0 Replaced, l Replacement            El Yes-C                          .                                                                                                                                      0 Repaired,                  0 No 0 Replaced;
                           .. ____            . ..                                                                          -                          .- ;    O Replacement                DYes D                                                                                                                                                                0  Repaired,                0 No 03Replaced,
                           .. ____            . ..                                                                          -                          .- ;    O Replacement                DYes D                                                                                                                                                                0  Repaired,                0 No 03Replaced,
Line 922: Line 874:
                           --p -le -- Valve,- Two
                           --p -le -- Valve,- Two
: 5. Pump or Valve Identifucationb (2),-2"-1500#- .GateYValYe.                                                                -
: 5. Pump or Valve Identifucationb (2),-2"-1500#- .GateYValYe.                                                                -
  .-                                                                          ,
                     ''Serial Numbers: E496P-I-1 and E496P-1-2                                              --        -            --                                      '
                     ''Serial Numbers: E496P-I-1 and E496P-1-2                                              --        -            --                                      '
(Brief description of clerlce for which equipment was designed) 74450            R/C                                      V1~Jwnr¶7v        Cornr---
(Brief description of clerlce for which equipment was designed) 74450            R/C                                      V1~Jwnr¶7v        Cornr---
Line 939: Line 890:
                                                                                                                     ... -. _... _      -- -.. . .. .1                          -
                                                                                                                     ... -. _... _      -- -.. . .. .1                          -
                             -nIIU      LI7aj        -
                             -nIIU      LI7aj        -
                                            ..          .. ...                      .        * .      ..          .        .      ,    .
(b) Forg inga.                                            - --                                                          -        _
(b) Forg inga.                                            - --                                                          -        _
Body; SN tl, SN 12                                            SA182F316                  BW/IP PumP Div.
Body; SN tl, SN 12                                            SA182F316                  BW/IP PumP Div.
Line 953: Line 903:
I                        .
I                        .
                                                                                   .4 I
                                                                                   .4 I
                                                                                                                     .4
                                                                                                                     .4 d5400
                                                                                                                          .-
d5400
: 8. Hyrostatic test~~                                psi CERTIFICATION OF DESIGN Designinhlormaiononfie at            Flowserve Corporation, Williamsport, PA.                                17701 Stress analysis report on file at                            Same as above Design pecifieuions certified by R. E.          Miller                                  (1) Prof. Eng.State        SC      Reg.No 4237 Stress analysis report certified by                          N/A                          (l)Prof. .Eng.St ce -              Reg. No.-
: 8. Hyrostatic test~~                                psi CERTIFICATION OF DESIGN Designinhlormaiononfie at            Flowserve Corporation, Williamsport, PA.                                17701 Stress analysis report on file at                            Same as above Design pecifieuions certified by R. E.          Miller                                  (1) Prof. Eng.State        SC      Reg.No 4237 Stress analysis report certified by                          N/A                          (l)Prof. .Eng.St ce -              Reg. No.-
(I) Signatwre not required. List name only.
(I) Signatwre not required. List name only.
Line 979: Line 927:
: 6. Identifcation of Compon nts Repaired or Replaced and Replacement Comionents:
: 6. Identifcation of Compon nts Repaired or Replaced and Replacement Comionents:
* Column 1                              Column 2-                -      Column 3                    Column 4                  Column 5          Col 6        Column 7                    Column 8 Name of Compone                        Name of Mfg                    Mfg Serial No.            National Board No.        Oter Identificaton Year Built Repaired, Replaced, or ASME Code Stamped
* Column 1                              Column 2-                -      Column 3                    Column 4                  Column 5          Col 6        Column 7                    Column 8 Name of Compone                        Name of Mfg                    Mfg Serial No.            National Board No.        Oter Identificaton Year Built Repaired, Replaced, or ASME Code Stamped
        ._                                ._            ._.,_.._,_._.,                                                ...
_.                                        Replacement                  (yes or no)
_.                                        Replacement                  (yes or no)
A                                                                                                                                                              0 Repaired,                  1H1No 2MCA-BB-5489                      Duke Power                              N/A                      N/A                      Hanger          N/A      0 Replaced,
A                                                                                                                                                              0 Repaired,                  1H1No 2MCA-BB-5489                      Duke Power                              N/A                      N/A                      Hanger          N/A      0 Replaced,
                                         ._      _    _      _        _      _      _    _                                                                    Replacemrient            0 Yes B                                                                                                                                                              0 Repaired,-                0 No 0 Replaced,
                                         ._      _    _      _        _      _      _    _                                                                    Replacemrient            0 Yes B                                                                                                                                                              0 Repaired,-                0 No 0 Replaced,
                              .      '
                                       ..      ..    .                                        .                          .  .0                                Replacement              0 Yes c                                                                                                                                                              0.Repaired,;                0 No      -
                                       ..      ..    .                                        .                          .  .0                                Replacement              0 Yes c                                                                                                                                                              0.Repaired,;                0 No      -
03Replaced,-
03Replaced,-
Line 1,019: Line 965:
_  ____...      .3_                                                                0Replacement              0 Yes E                                                                                                                                              ORepaired,,                O No 3OReplaced,
_  ____...      .3_                                                                0Replacement              0 Yes E                                                                                                                                              ORepaired,,                O No 3OReplaced,
                                                           .___3                                                                                0Replacement              0 Yes F                                                                                                                                              0;Repaired,              0 No' 03Replaced,
                                                           .___3                                                                                0Replacement              0 Yes F                                                                                                                                              0;Repaired,              0 No' 03Replaced,
        ._
__3    .                  .      .    .                                                  .                .0
__3    .                  .      .    .                                                  .                .0
_._..                            Replacement            0  Yes Page 1 of 2 Revision 7
_._..                            Replacement            0  Yes Page 1 of 2 Revision 7
Line 1,056: Line 1,001:
                           ..                                                                                                                                          0 Replacement                0Yes Page I of 2 Revision 7
                           ..                                                                                                                                          0 Replacement                0Yes Page I of 2 Revision 7


                                                                                                                                - -
Form NIS-2 (Back)
Form NIS-2 (Back)
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
Line 1,064: Line 1,008:
CERTIFICATE OF COMPLIANCE We certify that the statements made iq the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.
CERTIFICATE OF COMPLIANCE We certify that the statements made iq the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A                                  Expiration Date N/A Signed                      FL Grass Jr.. QA Tech Soecialist M _ .  .,  .
Type Code Symbol Stamp N/A Certificate of Authorization No. N/A                                  Expiration Date N/A Signed                      FL Grass Jr.. QA Tech Soecialist M _ .  .,  .
                                                                            -
Date 2        6/OsY Owner,6r Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTiON 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period q- toa2 6^Dy : and state that to the bestof my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.,
Date 2        6/OsY Owner,6r Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTiON 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period q- toa2 6^Dy : and state that to the bestof my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.,
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspec n.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspec n.
Line 1,083: Line 1,026:
                                               ..          -              N56925-00-0001                        25 '                      N/A                  1974        El Replaced,
                                               ..          -              N56925-00-0001                        25 '                      N/A                  1974        El Replaced,
                             ._        ._        ._            .        :  .            .                            .        ...                                          0 Replacement            E Yes B                                                                                                                                                                            0 Repaired,              0 No 2-NC-VA-3                        Crosby                      N56925-00-0002                        26                        N/A                  1974            3 Replaced,
                             ._        ._        ._            .        :  .            .                            .        ...                                          0 Replacement            E Yes B                                                                                                                                                                            0 Repaired,              0 No 2-NC-VA-3                        Crosby                      N56925-00-0002                        26                        N/A                  1974            3 Replaced,
            .___
__El                _                                                        -I_._._                                                    _.                          Replacement        E    Yes C                                                                                                                                                                            0 Repaired,.              0 No 0 Replaced,
__El                _                                                        -I_._._                                                    _.                          Replacement        E    Yes C                                                                                                                                                                            0 Repaired,.              0 No 0 Replaced,
     . _____                          '    .    .  . ;'          . .  ,                          .    .          .                            .      - ..                      Replacement          0 Yes D3.-                                                              .                            .  .                                      .                    0 Repaired,              0 No
     . _____                          '    .    .  . ;'          . .  ,                          .    .          .                            .      - ..                      Replacement          0 Yes D3.-                                                              .                            .  .                                      .                    0 Repaired,              0 No
Line 1,105: Line 1,047:
4 J
4 J
C    0      3    Y      V A LV E            t            %>
C    0      3    Y      V A LV E            t            %>
_
W R E N TW1H A M,              M A S5 7-
W R E N TW1H A M,              M A S5 7-
                                                 *-..--        y *.; 70FR sAVETrY AND SAF-ETy RELIEP VALVES                                                Q.C.-44B 1;.                                                      At tCquxted by theC ptovIsions ol the ASSME Code Rules NB-26 DATA REPORT Safety and Safety Relief Valves                    REVISED 10/23/74 a
                                                 *-..--        y *.; 70FR sAVETrY AND SAF-ETy RELIEP VALVES                                                Q.C.-44B 1;.                                                      At tCquxted by theC ptovIsions ol the ASSME Code Rules NB-26 DATA REPORT Safety and Safety Relief Valves                    REVISED 10/23/74 a
Line 1,138: Line 1,079:
                                                 -- ' ": ::r : __.. ...                              Serial No. or                                                    Material Specification I              e. Boing
                                                 -- ' ": ::r : __.. ...                              Serial No. or                                                    Material Specification I              e. Boing
                                                                                                     -Identlifcation                                                  Including Type or Crade
                                                                                                     -Identlifcation                                                  Including Type or Crade
                                              . .
                                                                                 -'-. :  ..      NX-2761-0014                                    *-        AST            -3Cl4 Cr. 51,86O4                _
                                                                                 -'-. :  ..      NX-2761-0014                                    *-        AST            -3Cl4 Cr. 51,86O4                _
c.
c.
Line 1,159: Line 1,099:
pressed or implied. concerning the eq'uipraerft describee'. itt tt% [inta ecprt.Frur:lerrr.one. r.neier the Inspector cr.orflais erniolover shall be liab'e in any man.act . o: any personal inju:ry or property danmge of a loss (if ny 1an.d atisin, fru:n or canriectcd witl;this iIuspeettoo.
pressed or implied. concerning the eq'uipraerft describee'. itt tt% [inta ecprt.Frur:lerrr.one. r.neier the Inspector cr.orflais erniolover shall be liab'e in any man.act . o: any personal inju:ry or property danmge of a loss (if ny 1an.d atisin, fru:n or canriectcd witl;this iIuspeettoo.
_Xc                    ,      _          'y              tory Mutual' Group 6of Insurance Co.
_Xc                    ,      _          'y              tory Mutual' Group 6of Insurance Co.
_
                                                                                                           /Connmlss ions          h        -9              __                        z        -.
                                                                                                           /Connmlss ions          h        -9              __                        z        -.
fi    !n;pc  ;re:r-.r                                                                  11at
fi    !n;pc  ;re:r-.r                                                                  11at
                                                                                                                                                   ""~nard. State. Prsovince aiid N~
                                                                                                                                                   ""~nard. State. Prsovince aiid N~
I
I
      ..    .        - ..  ..  . .. - -                ... _-    -                .              -    -      -                                                      .---  ...-  .. . -


Co                                                        FORM NIS-2 OWNER'S RLhT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl C_
Co                                                        FORM NIS-2 OWNER'S RLhT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl C_
Line 1,178: Line 1,116:
                                 ._ I_    ,_.._._._.                                                                                                .      Replacement                  (yes or no)
                                 ._ I_    ,_.._._._.                                                                                                .      Replacement                  (yes or no)
A                                                                                                                                                      0 Repaired,                  El No 2-MCR-NC-SG-A                        Duke Power                        4                          N/A        .        N/A            N/A      0 Replaced,
A                                                                                                                                                      0 Repaired,                  El No 2-MCR-NC-SG-A                        Duke Power                        4                          N/A        .        N/A            N/A      0 Replaced,
                                                      ..
                                                      ._____
                                                       ..        _  . - .            _:    .                          ..                      E      l    Replacement              0 Yes B                                            .                                                                                                            Repaired,                0 No 0 Replaced,
                                                       ..        _  . - .            _:    .                          ..                      E      l    Replacement              0 Yes B                                            .                                                                                                            Repaired,                0 No 0 Replaced,
                                                             . ._        ..        __    .                                                            OReplacement                O Yes C                            .                                                                .                  .                                    0 Repaired,,                0 No 0 Replaced,
                                                             . ._        ..        __    .                                                            OReplacement                O Yes C                            .                                                                .                  .                                    0 Repaired,,                0 No 0 Replaced,
                                    .    .__  .-
_____    .                                        _                                __                      OReplacement                0 Yes D                                                                                                                                                      0 Repaired,                  0 No 0:Replaced,.
_____    .                                        _                                __                      OReplacement                0 Yes D                                                                                                                                                      0 Repaired,                  0 No 0:Replaced,.
:_  __                      __                                  -                      _._._._.                0 Replacement                0 Yes.
:_  __                      __                                  -                      _._._._.                0 Replacement                0 Yes.
E                      -. ..                                                    .                                                                      0 Repaired,                  0 No 0 Replaced,
E                      -. ..                                                    .                                                                      0 Repaired,                  0 No 0 Replaced,
                      .    ._
                             ._        .      .._  _    _  _      ...      _    _    _                                                              OReplacement                0 Yes F                .0..                                                                                                                                  0 Repaired,                0 No 0 Replaced,
                             ._        .      .._  _    _  _      ...      _    _    _                                                              OReplacement                0 Yes F                .0..                                                                                                                                  0 Repaired,                0 No 0 Replaced,
             .                                          .                                                                              :              O0 Replacement              0 Yes      --
             .                                          .                                                                              :              O0 Replacement              0 Yes      --
Line 1,304: Line 1,238:


     . I      1
     . I      1
         - 26151.(R-6)                                                                                                Forrn930.1A Rev.5 DUKE POWER COMPANY
         - 26151.(R-6)                                                                                                Forrn930.1A Rev.5 DUKE POWER COMPANY QUALITY ASSURANCE DEPARTMENT SUPPUER QUALITY ASSURANCE CERTIFICATION Name of SupplierBaSEl              t I(tJtJ 51i      5,!c      Date Address of Supplier Plant                            I4EEtfI 6 7Mill Per Order No. A+/-Q1              IJ77 i, 32A5NCRZi,  *                  .. . . . ..A L-.
.
QUALITY ASSURANCE DEPARTMENT SUPPUER QUALITY ASSURANCE CERTIFICATION Name of SupplierBaSEl              t I(tJtJ 51i      5,!c      Date Address of Supplier Plant                            I4EEtfI 6 7Mill Per Order No. A+/-Q1              IJ77
          -
i, 32A5NCRZi,  *                  .. . . . ..A L-.
                                         . . 6AJdA
                                         . . 6AJdA
                                       .. Pq                                Duke item or Req. No.  -
                                       .. Pq                                Duke item or Req. No.  -
Line 1,341: Line 1,271:
                                       ._ I_                            ..      .  .,                                        _                                      0..
                                       ._ I_                            ..      .  .,                                        _                                      0..
O Replacement            0 Yes D                                                                                                                                                                  0 Repaired,.            0 No 03 Replaced,
O Replacement            0 Yes D                                                                                                                                                                  0 Repaired,.            0 No 03 Replaced,
                                        .__-_ ..
                                       .______            .                                  _  ;        ...                                                      OReplacement            OYes E                                                                                                                                                                  0 Repaired,.            0 No, 0 Replaced,
                                       .______            .                                  _  ;        ...                                                      OReplacement            OYes E                                                                                                                                                                  0 Repaired,.            0 No, 0 Replaced,
                                             .                --          ..                    ._    ._                  .          .3                          OReplacement            O Yes F                              .        ..                  - ..                                                .                                                  0 Repaired,,            0 No
                                             .                --          ..                    ._    ._                  .          .3                          OReplacement            O Yes F                              .        ..                  - ..                                                .                                                  0 Repaired,,            0 No
Line 1,360: Line 1,289:
('2
('2
: 1. Owner Address:            Duke Power Comoanv                                                                                                                                                                          Ia. Date March 23. 2005
: 1. Owner Address:            Duke Power Comoanv                                                                                                                                                                          Ia. Date March 23. 2005
                              .
                                       ~w
                                       ~w
                                   -j-0 (hak .. h of-
                                   -j-0 (hak .. h of-
Line 1,379: Line 1,307:
A            2A Steam                                                                                                                                                                                            03Repaired,              0 No Generator                            'B&W-                                          770002                                      159                  '~PO# C23355                  1996 0 Replaced,
A            2A Steam                                                                                                                                                                                            03Repaired,              0 No Generator                            'B&W-                                          770002                                      159                  '~PO# C23355                  1996 0 Replaced,
___      __    ___      __    _____          ___          __      ___        _    ___      __    ___      __                          ~R                          eplacem ent          2 1 Yes B                                                                                                                                                                                                          .0      Repaired,-              0 No 0 Replaced,
___      __    ___      __    _____          ___          __      ___        _    ___      __    ___      __                          ~R                          eplacem ent          2 1 Yes B                                                                                                                                                                                                          .0      Repaired,-              0 No 0 Replaced,
___
__      __
__  __
__    __      __
__0  _        __                                                                                                                      Replacem ent            0 Yes 0 Repaired,                0 No 0 Replaced,'.
__0  _        __                                                                                                                      Replacem ent            0 Yes 0 Repaired,                0 No 0 Replaced,'.
___        __      __      __    __    ____                                            __    __    __    _3                  R eplacem ent            03Y es  '
___        __      __      __    __    ____                                            __    __    __    _3                  R eplacem ent            03Y es  '
Line 1,410: Line 1,334:
A.4.1--
A.4.1--
     %JvwnUIrffruurrass; M..t.-  r!l-.-.
     %JvwnUIrffruurrass; M..t.-  r!l-.-.
                                 *u~rsU FVwtI 'JVIIIdIIV                                                    -Y                                                                                  Ia. Date March 21. 2005
                                 *u~rsU FVwtI 'JVIIIdIIV                                                    -Y                                                                                  Ia. Date March 21. 2005 Sheet I            of i
                                                                                                            .
Sheet I            of i
: 2. Plant Address:              McGuire Nuclear Station 12700 Hagers Ferry Road. Huntersville. NC 28078 2a. Unit: 01        02        -03        OShared (specify Units                                                )__
: 2. Plant Address:              McGuire Nuclear Station 12700 Hagers Ferry Road. Huntersville. NC 28078 2a. Unit: 01        02        -03        OShared (specify Units                                                )__
: 3. Work Performed By: Duke Power Comoanv                                                                                                                    3a. Work Order #:                    98653488 Address:                        526 S. Church Street. Charlotte NC 28201-1006                                                                                                          RepWr Orgarizeflon Job
: 3. Work Performed By: Duke Power Comoanv                                                                                                                    3a. Work Order #:                    98653488 Address:                        526 S. Church Street. Charlotte NC 28201-1006                                                                                                          RepWr Orgarizeflon Job
Line 1,456: Line 1,378:
: 6. Identification of Components Repaired or Replaced and Replacement Con ponents:                                                          --      _                    :II      _
: 6. Identification of Components Repaired or Replaced and Replacement Con ponents:                                                          --      _                    :II      _
= Column 1                        :      Column 2                        Column 3                  Column 4        .      Column 5          Col 6        Column 7                  Column 8 Name of Component                    Name of Mftg      ;            Mfg Serial No.          National Board No.      Otew Identification Year Built Repaired. Replaced, or ASME Code Stamped
= Column 1                        :      Column 2                        Column 3                  Column 4        .      Column 5          Col 6        Column 7                  Column 8 Name of Component                    Name of Mftg      ;            Mfg Serial No.          National Board No.      Otew Identification Year Built Repaired. Replaced, or ASME Code Stamped
                        .___
___  ___  ____..    .-                      ________            _                                                                Replacem ent                (yes or no) -
___  ___  ____..    .-                      ________            _                                                                Replacem ent                (yes or no) -
A                                                                                                                                                          CIRepaired,0 No NS Piping                  DLuke Power ;.                    I    N/A      ..              69            :      2NS              1982      0 Replaced,
A                                                                                                                                                          CIRepaired,0 No NS Piping                  DLuke Power ;.                    I    N/A      ..              69            :      2NS              1982      0 Replaced,
Line 1,478: Line 1,399:
                                     -fgrome F Swan        Commissions          NC1524. N-I Inspect        ure                                    National Board, State, Province and Endorsements Page 2 of 2 Revision 7
                                     -fgrome F Swan        Commissions          NC1524. N-I Inspect        ure                                    National Board, State, Province and Endorsements Page 2 of 2 Revision 7


                                                                                                                                  '..
FORM NIS-2 OWNER'S RELAT FOR REPAIRS OR REPLACEMENTS As Requlred By The Provislons Of The ASME Code Section XI C
FORM NIS-2 OWNER'S RELAT FOR REPAIRS OR REPLACEMENTS As Requlred By The Provislons Of The ASME Code Section XI C
: 1. Owner Address:              Duke Power Comranv                                                                                                                                          1a. Date 04/04/2005 526 S. Church Street. Chaflotte.'NC 28201-1006                                                                                                                    Sheet 1 of 1
: 1. Owner Address:              Duke Power Comranv                                                                                                                                          1a. Date 04/04/2005 526 S. Church Street. Chaflotte.'NC 28201-1006                                                                                                                    Sheet 1 of 1
Line 1,492: Line 1,412:
_  __ _ _ _ __ __ _ _  __ _ _    _    _    _  _  _      _  _  _ _ _  _ _  _ _  _ _  _ _ _ _R                                      eplacem ent            (yes or no)
_  __ _ _ _ __ __ _ _  __ _ _    _    _    _  _  _      _  _  _ _ _  _ _  _ _  _ _  _ _ _ _R                                      eplacem ent            (yes or no)
A                                                                                                        .Repaired,                                                                                          0 No NS Plping                    .. Duke Power                                            N/A                          69                    2NS            1982    0 Replaced,
A                                                                                                        .Repaired,                                                                                          0 No NS Plping                    .. Duke Power                                            N/A                          69                    2NS            1982    0 Replaced,
__._.___._-_,_:_._                                                                -                  .      .
_OReplacem .                    . .                      ent      ElYes B                                                                                                                                                                                  0 Repaired,              0 No 03Replaced,
_OReplacem .                    . .                      ent      ElYes B                                                                                                                                                                                  0 Repaired,              0 No 03Replaced,
______                                                        :                                                                            ____    O Replacement            0 Yes C                                                                                                                                                                                  0 Repaired,              0 No..-
______                                                        :                                                                            ____    O Replacement            0 Yes C                                                                                                                                                                                  0 Repaired,              0 No..-
Line 1,517: Line 1,436:
: 3. Work Performed By: Duke Power ComDanv                                                -                                          *3a. Work Order #: 98663764 Address:                    526 S. Church Street. Charlotte NC 28201-1006                                                                              Replr Orgarlalon Job #
: 3. Work Performed By: Duke Power ComDanv                                                -                                          *3a. Work Order #: 98663764 Address:                    526 S. Church Street. Charlotte NC 28201-1006                                                                              Replr Orgarlalon Job #
Type Code Symbol Stamp: SA Authorization No. N/A Expiration Date: WA                                                            3b. NSM or MM #:      N/A A
Type Code Symbol Stamp: SA Authorization No. N/A Expiration Date: WA                                                            3b. NSM or MM #:      N/A A
_.
flIr,1dionfifiptlofnn nf li~otgam*                MV    I                                  A        thl l"na^ ,J  vOtm-        R
flIr,1dionfifiptlofnn nf li~otgam*                MV    I                                  A        thl l"na^ ,J  vOtm-        R
: 5. (a) Applicable Construction Code: ASME III 19Zg.            Edition, Summer and Winter Addenda,                          N/A                                      Code Cases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
: 5. (a) Applicable Construction Code: ASME III 19Zg.            Edition, Summer and Winter Addenda,                          N/A                                      Code Cases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
Line 1,547: Line 1,465:


C                                                FORM NIS-2 OWNER'S RL..hT FOR REPAIRS OR REPLACEMENTS                                                                                  IIj; As Required By The Provisions Of The ASME Code Section Xl
C                                                FORM NIS-2 OWNER'S RL..hT FOR REPAIRS OR REPLACEMENTS                                                                                  IIj; As Required By The Provisions Of The ASME Code Section Xl
: 1. Owner Address:        Duke Power Comwanv                                                                                                            .        la. Date 04/06/2005-526 S. Church Street. Charlotte. NC 28201-1006                                                                                              Sheet        I  of 1
: 1. Owner Address:        Duke Power Comwanv                                                                                                            .        la. Date 04/06/2005-526 S. Church Street. Charlotte. NC 28201-1006                                                                                              Sheet        I  of 1 p.
                                                                                                ,.'
p.
: 2. Plant Address:        McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville. NC 28078 2a. Unit: 01      02J2  03    OShared (specify Units                              )
: 2. Plant Address:        McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville. NC 28078 2a. Unit: 01      02J2  03    OShared (specify Units                              )
: 3. Work Performed By:      Duke Power ComDanv                                                                                    *3a. Work Order # : 98663764/13 Address:                526 5.Church Street. Chariotte NC 28201-1006                                                                                      Repir Orga        Job #
: 3. Work Performed By:      Duke Power ComDanv                                                                                    *3a. Work Order # : 98663764/13 Address:                526 5.Church Street. Chariotte NC 28201-1006                                                                                      Repir Orga        Job #
Line 1,588: Line 1,504:
: 3. Work Performed By Duke Power Companv                        -                                                                                      3a. Work Order # : 98664169/01 Address:                    526 S. Church Street. Charlotte NC 28201-1006                                                                                                    Repalr Organftn Job *    -
: 3. Work Performed By Duke Power Companv                        -                                                                                      3a. Work Order # : 98664169/01 Address:                    526 S. Church Street. Charlotte NC 28201-1006                                                                                                    Repalr Organftn Job *    -
Type Code Symbol Stamp:                  Authorization
Type Code Symbol Stamp:                  Authorization
                                             -                No. N/A Expiration Date: N/A                                                            '3b. NSM or MM#:            N/A A-  (5a lrlontiflirtinn of Rvqtcamri
                                             -                No. N/A Expiration Date: N/A                                                            '3b. NSM or MM#:            N/A A-  (5a lrlontiflirtinn of Rvqtcamri NV' 4A- (hi Clasq of Svstem:            B                                                        .:
      .                  -  .
NV'
                                                          -.          .-
4A- (hi
                                                                                                                        -
Clasq of Svstem:            B                                                        .:
: 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda,:                                                      N/A                                          Code Cases (b) Appiicable Edition of Section XI Utilized for Repairs or Replacements: 1998.2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
: 5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda,:                                                      N/A                                          Code Cases (b) Appiicable Edition of Section XI Utilized for Repairs or Replacements: 1998.2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
: 6. Identification of Components Repaired or Replaced and Replacement Corn onents:                                                    _      _--
: 6. Identification of Components Repaired or Replaced and Replacement Corn onents:                                                    _      _--
Line 1,605: Line 1,515:
                                 .___. ___ . . ..                            ..                        .__.                                                    .0              Replacement            0Yes D                                                                                                                                                                          0 Repaired,              0 No
                                 .___. ___ . . ..                            ..                        .__.                                                    .0              Replacement            0Yes D                                                                                                                                                                          0 Repaired,              0 No
                 .___                  .      . .      :      .        : .          .      .    .    .  -        ;.                  '0                                    R eplaced,'
                 .___                  .      . .      :      .        : .          .      .    .    .  -        ;.                  '0                                    R eplaced,'
                . .            ..  ...          .      .,
___._.___,_.      .  .        .              .                                                                            0 Replacement            0  Yes          -
___._.___,_.      .  .        .              .                                                                            0 Replacement            0  Yes          -
E                .                                                                                                                                                          0 Repaired,            0 No 0 Replaced,
E                .                                                                                                                                                          0 Repaired,            0 No 0 Replaced,
Line 1,627: Line 1,536:
: 2. Plant Address:            McGuire Nuclear Station 12700 haaers FerrV Road. Huntersville. NC 28078 2a. Unit:  01    02        03      OShardd (specify Units                                          )
: 2. Plant Address:            McGuire Nuclear Station 12700 haaers FerrV Road. Huntersville. NC 28078 2a. Unit:  01    02        03      OShardd (specify Units                                          )
: 3. Work Performed By Duke Power Companv                                                                                                        3a. Work Order # : 98665743-05 Address:          ;      526 S. Church Street. Charlotte NC 28201-1006                                                                                            Repair Organrzeion Job C Type Code Symbol Stamp: N                Authorization No. NIA Expiratlon Date: N                                                          3b. NSM or MM #:              N/A
: 3. Work Performed By Duke Power Companv                                                                                                        3a. Work Order # : 98665743-05 Address:          ;      526 S. Church Street. Charlotte NC 28201-1006                                                                                            Repair Organrzeion Job C Type Code Symbol Stamp: N                Authorization No. NIA Expiratlon Date: N                                                          3b. NSM or MM #:              N/A
                              ;  ..        .      .    -
: 4. (a) Identification of System: -_                          NV                                              4. (b) Class of System:            A
: 4. (a) Identification of System: -_                          NV                                              4. (b) Class of System:            A
: 5. (a)' Applicable Construction Cbde: ASME Ill 19Z7 Edition Summer and Winter Addenda,                                                    N/A                                        Code Cases.
: 5. (a)' Applicable Construction Cbde: ASME Ill 19Z7 Edition Summer and Winter Addenda,                                                    N/A                                        Code Cases.
Line 1,666: Line 1,574:
                               .________                  .__        .__ .__ *            ..                          .      ..                                          Replacem ent          !E3Yes B                                                                                                                                                                        0l Repaired,_            0 No 0 Replaced,'
                               .________                  .__        .__ .__ *            ..                          .      ..                                          Replacem ent          !E3Yes B                                                                                                                                                                        0l Repaired,_            0 No 0 Replaced,'
_________________                                                    .______                                                    . 0 Replacement              O Yes C                                                                                                                                                                      0    Repaired,            O No-0    Replaced,                      -
_________________                                                    .______                                                    . 0 Replacement              O Yes C                                                                                                                                                                      0    Repaired,            O No-0    Replaced,                      -
_____
r        _____    ._        ,.                      ..                                .'                                    ,      0    Replacement          0 Yes          '
r        _____    ._        ,.                      ..                                .'                                    ,      0    Replacement          0 Yes          '
D                                                                                                                                                                      0    Repaired,            0 No 0    Replaced, -
D                                                                                                                                                                      0    Repaired,            0 No 0    Replaced, -
                               .      ._                    :          .. _  _  _  _ _      _  _    :-_                                _ _ _ _ _                    0..Replacement          0 Yes E        .      -                                                                                                                                                    0 Repaired,                0 No 03Replaced,
                               .      ._                    :          .. _  _  _  _ _      _  _    :-_                                _ _ _ _ _                    0..Replacement          0 Yes E        .      -                                                                                                                                                    0 Repaired,                0 No 03Replaced,
                                       ._                                . _.        _.          _._;.                                                                O Replacement              O Yes F                                                                                                                                                                        0 Repaired,-            0 No 0 Replaced,
                                       ._                                . _.        _.          _._;.                                                                O Replacement              O Yes F                                                                                                                                                                        0 Repaired,-            0 No 0 Replaced,
                              .___      .#
____      __        ._
_          ..                                ..                                                        0 Replacement            0  Yes Page 1 of 2 Revision 7
_          ..                                ..                                                        0 Replacement            0  Yes Page 1 of 2 Revision 7


Line 1,727: Line 1,632:
Repair Organization Job #
Repair Organization Job #
Type Code Symbol Stamp:              AQAuthorization No.      9 Expiration Date: N/A                                            3b. NSM or MM #:                  N/A
Type Code Symbol Stamp:              AQAuthorization No.      9 Expiration Date: N/A                                            3b. NSM or MM #:                  N/A
                                                                                                                                                                        .....
: 4. (a) Identification of System:                            NV                                      4.* (b) Class of System:          B
: 4. (a) Identification of System:                            NV                                      4.* (b) Class of System:          B
: 5. (a) Applicable Construction Code: ASMEIII 1971 Edition, Summer and Winter Addenda,                                        N/A.                                              Code Cases (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
: 5. (a) Applicable Construction Code: ASMEIII 1971 Edition, Summer and Winter Addenda,                                        N/A.                                              Code Cases (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
Line 1,776: Line 1,680:
                         ._3                                                                          .                                            -              -..Replacement O                      0Yes F                                                                                                                                                              0 Repaired,                  0 No,
                         ._3                                                                          .                                            -              -..Replacement O                      0Yes F                                                                                                                                                              0 Repaired,                  0 No,
                                         -        .0                                                                                                              Replaced,
                                         -        .0                                                                                                              Replaced,
                    .    -_-_ ._
_      :    --          .        -    ._.:                            :                                    .                0 Replacement                0 Yes
_      :    --          .        -    ._.:                            :                                    .                0 Replacement                0 Yes
                                                                                                                                                                                                 -      Page I of 2 Revision 7
                                                                                                                                                                                                 -      Page I of 2 Revision 7
Line 1,790: Line 1,693:
                                           ,      Jr. QA Tech Specialist ers Designee, Title Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSiCTsjhave inspct            he components described in this Owners Report during the period 119=7S  to t                  and state that to the best of my knowledge and belief, the Owner his pehformed examinatlons and taken corrective measures described in this Owners Report in accordance with the requirements of ASME Code, Section Xl.
                                           ,      Jr. QA Tech Specialist ers Designee, Title Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSiCTsjhave inspct            he components described in this Owners Report during the period 119=7S  to t                  and state that to the best of my knowledge and belief, the Owner his pehformed examinatlons and taken corrective measures described in this Owners Report in accordance with the requirements of ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore,        ither the Inspector nor his employer shall be liable in any manner for ny personal injury or roperty damage or a loss of any kind arising from or connected with this lisp      cion.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore,        ither the Inspector nor his employer shall be liable in any manner for ny personal injury or roperty damage or a loss of any kind arising from or connected with this lisp      cion.
                      >
me F Swan      Commissions        NC1524, N-I np      ' tNational                                          Board, State, Province and Endorsements Page 2 of 2 Revision 7
me F Swan      Commissions        NC1524, N-I np      ' tNational                                          Board, State, Province and Endorsements Page 2 of 2 Revision 7


Line 1,903: Line 1,805:
_ _  _  _ _ _ _  _  _  _ _ _ _ __  __ _  _ _  _ _  _ _ _  _ _  _ _  _ _ _ _ _R                                          ep iacem ent          (ye or no)
_ _  _  _ _ _ _  _  _  _ _ _ _ __  __ _  _ _  _ _  _ _ _  _ _  _ _  _ _ _ _ _R                                          ep iacem ent          (ye or no)
A                                                                                                                                                                          0,Repaired,              El No 2-MCR-CF-H402                          . Duke Power                          33795                            N/A                    N/A                N/A      E Replaced,
A                                                                                                                                                                          0,Repaired,              El No 2-MCR-CF-H402                          . Duke Power                          33795                            N/A                    N/A                N/A      E Replaced,
                                                  -_____
                                                       - :          -:                        _    __;  ..                                                                O Replacement            0 Yes B                                                    :.                                                                                                                      Repaired,              El No 2-MCR-CF-H402                            Duke Power                            15705                          N/A                    N/A                N/A      0 Replaced,
                                                       - :          -:                        _    __;  ..                                                                O Replacement            0 Yes B                                                    :.                                                                                                                      Repaired,              El No 2-MCR-CF-H402                            Duke Power                            15705                          N/A                    N/A                N/A      0 Replaced,
_ ___      ___      ___      ___    .      .        -.                                                                                                                Replacement            O3 Yes C                                                                                                                                                                          0 Repaired,              0 No--.
_ ___      ___      ___      ___    .      .        -.                                                                                                                Replacement            O3 Yes C                                                                                                                                                                          0 Repaired,              0 No--.
Line 1,930: Line 1,831:
2a. Unit:    01    02        03    OShared (specify Units              '_)
2a. Unit:    01    02        03    OShared (specify Units              '_)
: 3. Work Performed By: 'Duke Power Comranv                                                                                                  3a. Work Order #: "              98709200 Address:                  526 S. Church Street. Charlotte NC 28201-1006                                                                                          Repair Organiatin Job Type Code Symbol Stamp: NIA Authorization No. NQ Expiration Date: N/A                                                                  3b. NSM or MM #-_    ,_
: 3. Work Performed By: 'Duke Power Comranv                                                                                                  3a. Work Order #: "              98709200 Address:                  526 S. Church Street. Charlotte NC 28201-1006                                                                                          Repair Organiatin Job Type Code Symbol Stamp: NIA Authorization No. NQ Expiration Date: N/A                                                                  3b. NSM or MM #-_    ,_
                                                                                                                                                                  ,.
N/A
N/A
                                                                                                                                                                               . vf  f
                                                                                                                                                                               . vf  f
Line 1,984: Line 1,884:
                                 .. - ___    ___    .                        _;_._;      _      ._.                                                            0Replacement                0 Yes 0 Repaired,                    0 No.
                                 .. - ___    ___    .                        _;_._;      _      ._.                                                            0Replacement                0 Yes 0 Repaired,                    0 No.
                                                                                             .                                                                  0.Replaced,'
                                                                                             .                                                                  0.Replaced,'
              .__          .        .
__    .      .                                                    .      ..                    _._.                      0 Replacement                  0 Yes Page 1 of 2 Revision 7
__    .      .                                                    .      ..                    _._.                      0 Replacement                  0 Yes Page 1 of 2 Revision 7


Line 2,015: Line 1,914:
                                                 .                                    .                                __.                  .    ..3 .Replacement            0Yes -
                                                 .                                    .                                __.                  .    ..3 .Replacement            0Yes -
D                                                                                                                                                0 Repaired,                O No 0 Replaced,
D                                                                                                                                                0 Repaired,                O No 0 Replaced,
              .____
___                            -__                                                      ._                        _            . 0 Replacement
___                            -__                                                      ._                        _            . 0 Replacement
                                                                                                                                                       ,- .. .                0Yes E                                                                                                                                                0 Repaired,                0 No 0 Replaced,
                                                                                                                                                       ,- .. .                0Yes E                                                                                                                                                0 Repaired,                0 No 0 Replaced,
Line 2,095: Line 1,993:
           /ispection.        f lerome F Swan        Commissions          NC1524, N-I Inspector                                              National Board, State, Province and Endorsements 6            Date Page 2 of 2 Revision 7
           /ispection.        f lerome F Swan        Commissions          NC1524, N-I Inspector                                              National Board, State, Province and Endorsements 6            Date Page 2 of 2 Revision 7


FORM NIS-2 OWNER'S RL RT FOR REPAIRS OR REPLACEMENTS                                                                                      C;
FORM NIS-2 OWNER'S RL RT FOR REPAIRS OR REPLACEMENTS                                                                                      C; As Required By The Provisions Of The ASME Code Section XI
                                                            .
                                                              .
As Required By The Provisions Of The ASME Code Section XI
: 1. Owner Address:        Duke Power Comoanv                                                                                                                                              la. Date 03/30/2005 526 S. Church Street. Charlotte. NC 28201-1006                                                                                                                        Sheet 1 of 1
: 1. Owner Address:        Duke Power Comoanv                                                                                                                                              la. Date 03/30/2005 526 S. Church Street. Charlotte. NC 28201-1006                                                                                                                        Sheet 1 of 1
: 2. Plant Address:        McGuire Nuclear Station 12700 Haaers Ferrv Road. Huntersville, NC 28078 2a. Unit: 01      02      033    iShared (specify Units                                            )
: 2. Plant Address:        McGuire Nuclear Station 12700 Haaers Ferrv Road. Huntersville, NC 28078 2a. Unit: 01      02      033    iShared (specify Units                                            )
Line 2,117: Line 2,012:
                                                                                 - .:                                                .                                        0 Replaced,
                                                                                 - .:                                                .                                        0 Replaced,
         .__                                -_ :      -.,        .      ..                                    ,                                              .0                  Replacement              0Yes E                        .                                                                                                                                                    0.Repaired,:              0 No 03Replaced,
         .__                                -_ :      -.,        .      ..                                    ,                                              .0                  Replacement              0Yes E                        .                                                                                                                                                    0.Repaired,:              0 No 03Replaced,
                                  ..
___    -__                                                                        .0                      _.._..__.                            Replacement              0  Yes F      .0                                                                                                                                                                        Repaired,              0 No 03Replaced,
___    -__                                                                        .0                      _.._..__.                            Replacement              0  Yes F      .0                                                                                                                                                                        Repaired,              0 No 03Replaced,
         .            .                        .                ..              .O0                                                                                              Replacement            0 Yes Page I of 2 Revision 7
         .            .                        .                ..              .O0                                                                                              Replacement            0 Yes Page I of 2 Revision 7
Line 2,141: Line 2,035:
: 6. Identification of Components Repaired or Repiaced and Replacement Com onents:
: 6. Identification of Components Repaired or Repiaced and Replacement Com onents:
Column 1                            Column 2                  Column 3                  Column 4              Column 5              Col 6        Column 7                Column 8 Name of Component                  Name of Mfg                Mfg Serial No.        National Board No. Oiler Identification    Year Built Repaired. Replaced, or ASME Code Stamped
Column 1                            Column 2                  Column 3                  Column 4              Column 5              Col 6        Column 7                Column 8 Name of Component                  Name of Mfg                Mfg Serial No.        National Board No. Oiler Identification    Year Built Repaired. Replaced, or ASME Code Stamped
__
__ ____  ___ ___ __ ____ __                      _  __  _  __    __    _Replacement                                (Wesor no)
__ ____  ___ ___ __ ____ __                      _  __  _  __    __    _Replacement                                (Wesor no)
A                                                                                                                                                  0 Repaired,                0l No 2-MCR-NI-4528                  Duke Power        ;-            5481                    N/A            -      N/A                  N/A    El Replaced, 0  Replacement              0 Yes B                                                                                                                                                  0 Repaired,                El No 2-MCR-NI-4528                  Duke Power                97 61426 0/40                  N/A                  N/A                  N/A    0 Replaced,
A                                                                                                                                                  0 Repaired,                0l No 2-MCR-NI-4528                  Duke Power        ;-            5481                    N/A            -      N/A                  N/A    El Replaced, 0  Replacement              0 Yes B                                                                                                                                                  0 Repaired,                El No 2-MCR-NI-4528                  Duke Power                97 61426 0/40                  N/A                  N/A                  N/A    0 Replaced,
Line 2,186: Line 2,079:
                               .                                  -                                                                                                                        O Replacement              0Yes D                                                                                                                                                                                          0 Repaired,              0 No 03Replaced,-
                               .                                  -                                                                                                                        O Replacement              0Yes D                                                                                                                                                                                          0 Repaired,              0 No 03Replaced,-
                                                               -_. :                                                            -                                      .;;0                  Replacement            0 Yes E                          :                    '                                                                    -                                                                  ORepaired,                0 No 0 Replaced,
                                                               -_. :                                                            -                                      .;;0                  Replacement            0 Yes E                          :                    '                                                                    -                                                                  ORepaired,                0 No 0 Replaced,
                              '
_____ --                                '_.__                __.                ._                                                  :0                      Replacement            0 Yes F                      -              -' '                                  '                                                                                                              0 Repaired,                0No 0 Replaced,
_____ --                                '_.__                __.                ._                                                  :0                      Replacement            0 Yes F                      -              -' '                                  '                                                                                                              0 Repaired,                0No 0 Replaced,
_ __ __ __ _ _ _ _ __ _ _ _ __ __ __ _ _ _ __ __ _ _ __ _ _  _ _ _ _ _ _ _  _ _ _  _ _ _ _  _ _ _    _ _ _    _ _ _  _ _ _ _  _ _ _0              Re placem en t0            Ye Page 1 of 2 Revision 7
_ __ __ __ _ _ _ _ __ _ _ _ __ __ __ _ _ _ __ __ _ _ __ _ _  _ _ _ _ _ _ _  _ _ _  _ _ _ _  _ _ _    _ _ _    _ _ _  _ _ _ _  _ _ _0              Re placem en t0            Ye Page 1 of 2 Revision 7
Line 2,228: Line 2,120:


Zone                                  Segment I EOC16 EComleio      EOC1 6 VT-2 Number          Boundary Dwg            Number          Status      Examination Date 22  2NC-001 L-A      MC-ISIL-2554-01.01          NV-030A        Complete          4/8/2005 23                                                NV-030B        Complete          4/8/2005 24                                                NV-032A        Complete          4/8/2005 25                                                NV-032B        Complete          4/8/2005 26                                                  NV-035        Complete          4/8/2005 27                                                  NV-036        Complete          4/8/2005 28                                                NV-039A        Complete          4/8/2005 29                                                NV-039B        Complete          4/8/2005 30                                                NV-040A        Complete          4/8/2005 31                                                NV-040B        Complete          4/8/2005 32                    MC-ISIL-2562-01.00            NI-068      Complete          4/8/2005 33                                                  N1-069      Complete          4/8/2005 34                                                  N1-070        Complete    1      4/8/2005 35                                                  NI-071        Comolete          4/8/2005 36 2ND-009L-B          MC-ISIL-2561 -01.00      ND-008C          Complete          3/3/2005 37                                              ND-009C          Complete          3/3/2005 38 2NI-061 L-B        MC-ISIL-2562-01.00          NI-063B        Complete          3/26/2005 39 2NV-003L-B          MC-ISIL-2554-01.03        3 2NV026        Complete          4/8/2005 40                                              3 2NV027        Complete          4/8/2005 41                                                4 NV-028      Complete          4/8/2005 4
Zone                                  Segment I EOC16 EComleio      EOC1 6 VT-2 Number          Boundary Dwg            Number          Status      Examination Date 22  2NC-001 L-A      MC-ISIL-2554-01.01          NV-030A        Complete          4/8/2005 23                                                NV-030B        Complete          4/8/2005 24                                                NV-032A        Complete          4/8/2005 25                                                NV-032B        Complete          4/8/2005 26                                                  NV-035        Complete          4/8/2005 27                                                  NV-036        Complete          4/8/2005 28                                                NV-039A        Complete          4/8/2005 29                                                NV-039B        Complete          4/8/2005 30                                                NV-040A        Complete          4/8/2005 31                                                NV-040B        Complete          4/8/2005 32                    MC-ISIL-2562-01.00            NI-068      Complete          4/8/2005 33                                                  N1-069      Complete          4/8/2005 34                                                  N1-070        Complete    1      4/8/2005 35                                                  NI-071        Comolete          4/8/2005 36 2ND-009L-B          MC-ISIL-2561 -01.00      ND-008C          Complete          3/3/2005 37                                              ND-009C          Complete          3/3/2005 38 2NI-061 L-B        MC-ISIL-2562-01.00          NI-063B        Complete          3/26/2005 39 2NV-003L-B          MC-ISIL-2554-01.03        3 2NV026        Complete          4/8/2005 40                                              3 2NV027        Complete          4/8/2005 41                                                4 NV-028      Complete          4/8/2005 4
42                                                  NV-029      Complete          4/8/2005 43 2NV-004L-B          MC-ISIL-2554-01.01      NV-020AD          Complete          2/22/2005 44                    MC-ISIL-2554-03.00      5 NV-019AA        Complete          2/22/2005 45                                              NV-019AB          Complete          2/22/2005 46                                              NV-019AD          Complete          2/22/2005 47                                                NV-019B        Complete          2/22/2005 48                                              NV-019D          Complete          2/22/2005 49                                              NV-020AA          Complete          2/22/2005 50                                              NV-020AB          Complete          2/22/2005 51                                              NV-020AE          Complete          2/22/2005 52                                                NV-021 A      Complete          2/22/2005 53                                                NV-021 B      Complete          2t22/2005 MC-ISIL-2554-03.01      6 NV-002AB        Complete          2/22/2005 54 55                                              NV-002D          Complete          2/22/2005 56                                              NV-019C          Complete          2/22/2005 57                                                NV-019E        Complete          2/22/2005 58 2NV-005L-B          MC-ISIL-2554-01.02        NV-080A
42                                                  NV-029      Complete          4/8/2005 43 2NV-004L-B          MC-ISIL-2554-01.01      NV-020AD          Complete          2/22/2005 44                    MC-ISIL-2554-03.00      5 NV-019AA        Complete          2/22/2005 45                                              NV-019AB          Complete          2/22/2005 46                                              NV-019AD          Complete          2/22/2005 47                                                NV-019B        Complete          2/22/2005 48                                              NV-019D          Complete          2/22/2005 49                                              NV-020AA          Complete          2/22/2005 50                                              NV-020AB          Complete          2/22/2005 51                                              NV-020AE          Complete          2/22/2005 52                                                NV-021 A      Complete          2/22/2005 53                                                NV-021 B      Complete          2t22/2005 MC-ISIL-2554-03.01      6 NV-002AB        Complete          2/22/2005 54 55                                              NV-002D          Complete          2/22/2005 56                                              NV-019C          Complete          2/22/2005 57                                                NV-019E        Complete          2/22/2005 58 2NV-005L-B          MC-ISIL-2554-01.02        NV-080A Comolete 4/8/2005    I 59                                              NV-080B          Comolete          4/8/2005    I 3 Part of this segment is also shown on drawing MC-ISIL-2554-01.01.
                                                    .      _ . .
Comolete
_  . .,,, _
4/8/2005    I 59                                              NV-080B          Comolete          4/8/2005    I 3 Part of this segment is also shown on drawing MC-ISIL-2554-01.01.
4 Part of this segment is also shown on drawing MC-ISIL-2554-01.00.
4 Part of this segment is also shown on drawing MC-ISIL-2554-01.00.
5 Part of this segment is also shown on drawing MC-ISIL-2554-03.01.
5 Part of this segment is also shown on drawing MC-ISIL-2554-03.01.
Line 2,274: Line 2,162:
* The Hartford Steam Boiler Inspection & Insurance Company of Connecticut 200 Ashford Center North Suite 205 Atlanta, GA. 30338-4860 (800) 417-3721 www.hsbct.com
* The Hartford Steam Boiler Inspection & Insurance Company of Connecticut 200 Ashford Center North Suite 205 Atlanta, GA. 30338-4860 (800) 417-3721 www.hsbct.com


            .
OWNER'S REPORT FOR INSERVICE INSPECTIONS MCGUIRE UNIT 2 2005 REFUELING OUTAGE 8 /EOC 16 (Second Interval)
OWNER'S REPORT FOR INSERVICE INSPECTIONS MCGUIRE UNIT 2 2005 REFUELING OUTAGE 8 /EOC 16 (Second Interval)
Plant Location: McGuire Nuclear Station 12700 Hager's Ferry Road Huntersville, North Carolina 28078 NRC Docket No. 50-370 National Board No. 84 Commercial Service Date: March 1, 1984 Document Completion Date: 712-26o5-Owner: Duke Energy Corporation 526 South Church St.
Plant Location: McGuire Nuclear Station 12700 Hager's Ferry Road Huntersville, North Carolina 28078 NRC Docket No. 50-370 National Board No. 84 Commercial Service Date: March 1, 1984 Document Completion Date: 712-26o5-Owner: Duke Energy Corporation 526 South Church St.
Line 2,479: Line 2,366:
B13.070.001    2RPV.CORE-SUP        MCM 2201.01-21        See Com      VT-3      SS        0.000        INSPECT WHEN STRUCTURE IS REMOVED NC                                                          0.000        FROM REACTOR VESSEL Class A                                                                                                PROCEDURE WDI.STD-088 Total 813.070 Items:      1 Total B13 Items:            4
B13.070.001    2RPV.CORE-SUP        MCM 2201.01-21        See Com      VT-3      SS        0.000        INSPECT WHEN STRUCTURE IS REMOVED NC                                                          0.000        FROM REACTOR VESSEL Class A                                                                                                PROCEDURE WDI.STD-088 Total 813.070 Items:      1 Total B13 Items:            4


- -        -
4.0      Results of Inspections Performed The results of each examination shown in the final Inservice Inspection Plan (Section 3 of this report) are included in this section. The completion date and status for each examination are shown. All examinations revealing reportable indications and any corrective action required as a result are described in further detail in Subsections 4.1 and 4.2. Corrective measures performed and limited examinations are described in further detail in Subsections 4.3 and 4.4.
4.0      Results of Inspections Performed The results of each examination shown in the final Inservice Inspection Plan (Section 3 of this report) are included in this section. The completion date and status for each examination are shown. All examinations revealing reportable indications and any corrective action required as a result are described in further detail in Subsections 4.1 and 4.2. Corrective measures performed and limited examinations are described in further detail in Subsections 4.3 and 4.4.
The information shown below is a field description for the reporting format included in this section of the report:
The information shown below is a field description for the reporting format included in this section of the report:
Line 2,546: Line 2,432:
Table 6-2 DetailedListinq of Examinations 2 nd Interval          VT-2 Inservice /                                                Completion        Examination Functional      Item Number        BoundaryDwg                Status              Date 1          C07.030.001          MCL-1554-5.0            Complete          02-22-2005 2          C07.030.002        MCL-2554-2.0            Complete          02-22-2005 3          C07.030.003        MCL-2554-3.0            Complete          02-21-2004 4          C07.030.004        MCL-2554-3.1            Complete          02-22-2005 5          C07.030.005        MCL-2561 -1.0            Complete          02-22-2005 6          C07.030.008        MCL-2562-2.1            Complete          02-13-2004 7          C07.030.009        MCL-2562-3.0            Complete          02-22-2005 8          C07.030.010        MCL-2562-3.1            Complete          12-09-2003 9          C07.030.039        MCL-2554-1.2            Complete          02-28-2005 EOC16 / Outage 8                                                                Page 1 of 3 McGuire Unit 2                                                                  Revision 0 Section 6 - Second Ten-Year Interval                                            April 14, 2005
Table 6-2 DetailedListinq of Examinations 2 nd Interval          VT-2 Inservice /                                                Completion        Examination Functional      Item Number        BoundaryDwg                Status              Date 1          C07.030.001          MCL-1554-5.0            Complete          02-22-2005 2          C07.030.002        MCL-2554-2.0            Complete          02-22-2005 3          C07.030.003        MCL-2554-3.0            Complete          02-21-2004 4          C07.030.004        MCL-2554-3.1            Complete          02-22-2005 5          C07.030.005        MCL-2561 -1.0            Complete          02-22-2005 6          C07.030.008        MCL-2562-2.1            Complete          02-13-2004 7          C07.030.009        MCL-2562-3.0            Complete          02-22-2005 8          C07.030.010        MCL-2562-3.1            Complete          12-09-2003 9          C07.030.039        MCL-2554-1.2            Complete          02-28-2005 EOC16 / Outage 8                                                                Page 1 of 3 McGuire Unit 2                                                                  Revision 0 Section 6 - Second Ten-Year Interval                                            April 14, 2005


            -  .
Table 6-2 DetailedListing of Examinations 2nd Interval          VT-2 Completion        Examination Hydrostatic    Item Number      Boundary Dwg          Status              Date 1        C07.040.005      MCH-2554-1.0        Complete          02-22-2005 2        C07.040.006      MCH-2554-1.1        Complete          02-22-2005 3        C07.040.007      MCH-2554-1.2        Complete          02-22-2005 4        C07.040.008      MCH-2554-1.3        Complete          10-04-2003 5        C07.040.01 0    MCH-2554-3.0        Complete          02-22-2005 6        C07.040.011      MCH-2554-3.1        Complete          02-22-2005 7        C07.040.014      MCH-2561-1.0        Complete          02-22-2005 8        C07.040.015      MCH-2562-1.0        Complete          02-22-2005 9        C07.040.018      MCH-2562-3.0        Complete          02-22-2005 10          C07.040.019      MCH-2562-3.1        Complete          05-26-2004 11          C07.040.021      MCH-2563-1.0        Complete          02-22-2005 12          C07.040.024      MCH-2571 -1.0      Complete          02-22-2005 13          C07.040.025      MCH-2572-1.0        Complete          05-26-2004 14          C07.040.026      MCH-2572-1.1        Complete          03-03-2004 15          C07.040.028      MCH-2572-3.0        Complete          02-26-2004 16          C07.040.031      MCH-2573-3.1        Complete          02-09-2005 17          C07.040.033      MCH-2574-4.0        Complete          02-28-2005 18          C07.040.034      MCH-2580-1.0        Complete          10-04-2003 19          C07.040.035      MCH-2584-1.0        Complete          02-15-2005 20          C07.040.036      MCH-2591 -1.1      Complete          02-15-2005 21          C07.040.037      MCH-2593-1.0        Complete          02-16-2005 22          C07.040.038      MCH-2593-1.3        Complete        02-16-2005 23          C07.040.039      MCH-2592-1.0        Complete        02-15-2005 24          C07.040.040      MCH-2593-1.2        Complete        02-16-2005 25          C07.040.042      MCH-2617-1.0        Complete        02-15-2005 26          C07.040.044      MCH-2604-3.0        Complete          02-28-2005 27          C07.040.048      MCH-2554-2.1        Complete        02-22-2005 EOC16 I Outage 8                                                        Page 2 of 3 McGuire Unit 2                                                          Revision 0 Section 6 - Second Ten-Year Interval                                    April 14, 2005 I
Table 6-2 DetailedListing of Examinations 2nd Interval          VT-2 Completion        Examination Hydrostatic    Item Number      Boundary Dwg          Status              Date 1        C07.040.005      MCH-2554-1.0        Complete          02-22-2005 2        C07.040.006      MCH-2554-1.1        Complete          02-22-2005 3        C07.040.007      MCH-2554-1.2        Complete          02-22-2005 4        C07.040.008      MCH-2554-1.3        Complete          10-04-2003 5        C07.040.01 0    MCH-2554-3.0        Complete          02-22-2005 6        C07.040.011      MCH-2554-3.1        Complete          02-22-2005 7        C07.040.014      MCH-2561-1.0        Complete          02-22-2005 8        C07.040.015      MCH-2562-1.0        Complete          02-22-2005 9        C07.040.018      MCH-2562-3.0        Complete          02-22-2005 10          C07.040.019      MCH-2562-3.1        Complete          05-26-2004 11          C07.040.021      MCH-2563-1.0        Complete          02-22-2005 12          C07.040.024      MCH-2571 -1.0      Complete          02-22-2005 13          C07.040.025      MCH-2572-1.0        Complete          05-26-2004 14          C07.040.026      MCH-2572-1.1        Complete          03-03-2004 15          C07.040.028      MCH-2572-3.0        Complete          02-26-2004 16          C07.040.031      MCH-2573-3.1        Complete          02-09-2005 17          C07.040.033      MCH-2574-4.0        Complete          02-28-2005 18          C07.040.034      MCH-2580-1.0        Complete          10-04-2003 19          C07.040.035      MCH-2584-1.0        Complete          02-15-2005 20          C07.040.036      MCH-2591 -1.1      Complete          02-15-2005 21          C07.040.037      MCH-2593-1.0        Complete          02-16-2005 22          C07.040.038      MCH-2593-1.3        Complete        02-16-2005 23          C07.040.039      MCH-2592-1.0        Complete        02-15-2005 24          C07.040.040      MCH-2593-1.2        Complete        02-16-2005 25          C07.040.042      MCH-2617-1.0        Complete        02-15-2005 26          C07.040.044      MCH-2604-3.0        Complete          02-28-2005 27          C07.040.048      MCH-2554-2.1        Complete        02-22-2005 EOC16 I Outage 8                                                        Page 2 of 3 McGuire Unit 2                                                          Revision 0 Section 6 - Second Ten-Year Interval                                    April 14, 2005 I
I
I
Line 2,566: Line 2,451:
. u 4~                                      I                              6__  _
. u 4~                                      I                              6__  _
D_
D_
_
__
_
_ _ _
_
_
EOC16 / Outage 8                                                          Page 3 of 3 McGuire Unit 2                                                            Revision 0 Section 6 - Second Ten-Year Interval                                      April 14,2005}}
EOC16 / Outage 8                                                          Page 3 of 3 McGuire Unit 2                                                            Revision 0 Section 6 - Second Ten-Year Interval                                      April 14,2005}}

Latest revision as of 17:43, 14 March 2020

Inservice Inspection Report End of Cycle 16 Refueling Outage
ML052010176
Person / Time
Site: Mcguire
Issue date: 07/14/2005
From: Gordon Peterson
Duke Power Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML052010176 (209)


Text

Duke GARY R. PETERSON UrPowere Vice President McGuire Nuclear Station A Duke Energy Company Duke Power MGOI VP / 12700 Hagers Ferry Road Huntersville, NC 28078-9340 704 875 5333 704 875 4809 fax grpeters@duke-energy.com July 14, 2005 U. S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 ATTENTION: Document Control Desk

Subject:

McGuire Nuclear Station, Unit 2 Docket No. 50-370 Inservice Inspection Report End of Cycle 16 Refueling Outage Attached are two separate Inservice Inspection Reports for inspections conducted prior to the conclusion of the end of cycle 16 (EOC-16) refueling outage for McGuire Nuclear Station (MNS),

Unit 2. Attachment No. 1 is the Inspection Report performed in accordance with the Third 10-Year Inservice Inspection Interval Plan.

By letter dated August 14, 2003 (Relief Request 03-004), Duke Energy Corporation, requested to extend the inspection interval for performing the McGuire, Unit 2 reactor vessel examinations beyond the one-year code allowable extension to encompass the Spring 2005 refueling outage. This relief was authorized by the NRC in a letter to Mr. G.R. Peterson, dated July 20, 2004.

Therefore, Attachment No. 2 is the Inspection Report documenting the reactor vessel examinations performed in accordance with the Second 10-Year Inservice Inspection Interval Plan. This report also includes a compilation of pressure tests conducted to complete the requirements for the third period of the second 10-year interval.

Section 4.4 of the attached reports list the limited examination item numbers to be processed in the near future by an appropriate relief request for review and approval by the NRC in accordance with 10CFR50.55a(a)(3)(i).

www. duke-energy. corn

U.S. Nuclear Regulatory Commission July 14, 2005 Page 2 Any questions on this matter should be directed to Norman T.

Simms, Regulatory Compliance, at (704) 875-4685.

Sincerely, G.R. Peterson Attachments

U.S. Nuclear Regulatory Commission July 14, 2005 Page 3 cc w/o att:

W. D. Travers, Regional Administrator U. S. Nuclear Regulatory Commission, Region II Atlanta Federal Center 61 Forsyth St., SW, Suite 23T85 Atlanta, GA 30303 S. E. Peters (Addressee Only)

NRC Project Manager (McGuire)

U. S. Nuclear Regulatory Commission One White Flint North, Mail Stop 0-8 G9 11555 Rockville Pike Rockville, MD 20852-2738 J.B. Brady NRC Senior Resident Inspector McGuire Nuclear Station

ATTACHMENT No. 1 INSERVICE INSPECTION REPORT Duke Power Company McGuire Nuclear Station Unit 2 Sixteenth Refueling Outage

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS

, As required by the Provisions of the ASME Code Rules

1. Owner:Duke Energy Corporation. 526 S. Church St.. Charlotte, NC 28201-1006 (Name and Address of Owner)
2. Plant: McGuire Nuclear Station, 12700 Hawer's Ferrv Road Huntersville. N.C. 28078 (Name and Address of Plant)
3. Plant Unit: 2 4. Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date: March 1. 1984 6. National Board Number for Unit 84
7. Components Inspected:

Component or Manufacturer or Manufacturer or State or National Appurtenance Installer Installer Serial Province No. Board No.

No.

See Section 1.1 in the Attached Report Note: Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 81/2 in. x 11 in., (2)information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Total number of pages contained in this report 121.

FORM NIS-1 (Back)

8. Examination Dates October 6,2003 to April 14,2005
9. Inspection Period Identification: First Period A1o0. Inspection Interval Identification: Third Interval
11. Applicable Edition of Section XI 1998 Addenda 2000
12. Date I Revision of Inspection Plan: December 9, 2003/ Revision 0
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. See Sections 2.0.3.0 and 6.0
14. Abstract of Results of Examinations and Tests. See Section 4.0 and 6.0
15. Abstract of Corrective Measures. See Subsection 4.3 We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section Xl, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicabl e) N/A Expiration Date N/A Date 6/e 7oS' Signed Duke Energy Corn. By LE e ,) w >

_;.4j+/-.O Owner //

V CERTIFICATE OF INSERVICE INSPECTION

>1, the undersigned, holding a valid commission iss ey the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of employed by CT of Connecticut havq inslcted the components described in this Owners Report during the period /2QQ3to OD/

J1 4 LL O5 and state that to the best of my knowledge and belief, the Owner has performed exahinna ons and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage Or a loss of any ki a om or connected with this inspection o - I t' t' Commissions /MO.(.I oL ,J .

InspectorlSignature National Board, State, Pfovince, and Endorsements Date s /V/Y4A0E

  • The Hartford Steam Boiler Inspection & Insurance Company of Connecticut 200 Ashford Center North Suite 205 Atlanta, GA. 30338-4860 (800) 417-3721 www.hsbct.com Il I

OWNER'S REPORT FOR INSER VICE INSPECTIONS MCGUIRE UNIT 2 2005 REFUELING OUTAGE 1/EOC 16 (Third Interval)

Plant Location: McGuire Nuclear Station 12700 Hager's Ferry Road Huntersville, North Carolina 28078 NRC Docket No. 50-370 National Board No. 84 Commercial Service Date: March 1,1984 Document Completion Date: _6__Y_____

Owner: Duke Energy Corporation 526 South Church St.

Charlotte, N.C. 28201-1006 Revision 0 Prepared By. 13W Sa--oa Date ,S-26-2005 Reviewed By: Date (>~05 Approved By. I, 1 IDate

DISTRIBUTION LIST

1. Duke Energy Corporation Inservice Inspection Plan Management (Original Copy)
2. McGuire Welding and Inspection Services (ISI Coordinator)
3. NRC Document Control Desk
4. The Hartford Steam Boiler Inspection and Insurance Company of Connecticut (AIA) c/o ANII at McGuire
5. State of North Carolina Department of Labor c/o J. M. Givens, Jr.
6. Nuclear GO Nuclear Assurance c/o Bruce Nardoci

TABLE OF CONTENTS Section Title Revision 1.0 General Information 0 2.0 Second Ten-Year Interval Inspection Status 0 3.0 Final Inservice Inspection Plan 0 4.0 Results of Inspections Performed 0 5.0 Owners Report for Repair / Replacement Activities 0 6.0 Pressure Testing 0

1.0 General Information This report describes the Inservice Inspection of Duke Energy Corporation's McGuire Nuclear Station Unit 2 during Outage 1 / EOC1 6. This is the First Outage of the First Inspection Period of the Third Ten-Year Interval. ASME Section Xl, 1998 Edition with the 2000 Addenda, was the governing Code for selection and performance of the ISI examinations.

Included in this report are the inspection status for each examination category, the final inservice inspection plan, the inspection results for each item examined, and corrective action taken when reportable conditions were found. In addition, there is an Owners Report for Repair / Replacement Section included for completed NIS-2 documentation of repairs and replacements.

1.1 Identification Numbers Manufacturer National Manufacturer or Installer State or Board Item or Installer Serial No. Province No. No.

Reactor Vessel Rotterdam 30664 NC-201819 Pressurizer Westinghouse 1491 NC-201818 W10285 Steam Generator 2A BWI 7700-02 NC-302674 159 Steam Generator 2B BWI 7700-04 NC-302675 161 Steam Generator 2C BWI 7700-01 NC-302676 158 Steam Generator 2D BWI 7700-03 NC-302677 160 Centrifugal Charging Pump Pacific Pumps 2A - 48584 N/A 25 2B- 48585 28 Containment Spray Heat Delta Southern Co. 2A-35005-73-3 NC-234203 3396 Exchanger Joseph Oat & (2B) 2514 NC-201822 5765 Sons, Inc.

Excess Letdown Heat Westinghouse 1810 NC-234264 1555 Exchanger Letdown Heat Exchanger Joseph Oat & 2049-2B NC-201842 553 Sons, Inc.

Reciprocating Charging Union Pump Co. N7210318-604 N/A N/A P ump_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

McGuire Unit 2 Page 1 of 5 Outage 1/EOC-16 Revision 0 Sectibn 1 May 26, 2005

1.1 Identification Numbers (Continued)

Manufacturer National Manufacturer or Installer State or Board Item or Installer Serial No. Province No. No.

2A 5-114E841 G02 Reactor Coolant Pump Westinghouse 2B 6-114E841 G02 N/A N/A 2C 7-114E841 G02 2D 8-114E841 G02 -

Reciprocating Charging Metal Bellows Company 74730-002 N/A 002 Pump Accumulator Reciprocating Charging Richmond Engineering N-2409.20 N/A 75220 Pump Suction Stabilizer Supply Co.

Residual Heat Joseph Oat & Sons, Inc. 2A 2046-2C NC-1 69800 637 Removal Heat 2B 2046-2D NC-201823 638 Exchanger Safety Injection Pump Pacific Pumps 2A 49357 N/A 130

. 2B 49358 131 Regenerative Heat Joseph Oat & Sons, Inc. 2047-2B NC-201817 628 Exchanger 629 630 Seal Water Heat Atlas Industrial 1767 NC 201827 1549 Exchanger Manufacturing Company Seal Water AMF Cuno 2A - 20 N/A 4364 Injection Filter 2B - 22 4365 Main Steam Supply to Duke Power Co. SA -N/A 62 Auxiliary Equipment System Containment Air Release Duke Power Co. VQ N/A 56 and Addition System Main Steam System Duke Power Co. SM N/A 70 Main Steam Vent to Duke Power Co. SV N/A 67 Atmosphere System  :

Reactor Coolant System Duke Power Co. NC N/A 82 McGuire Unit 2 Page 2 of 5 Outage llEOC-16 Revision 0 Section 1 May 26, 2005

1.1 Identification Numbers (Continued)

Manufacturer Manufacturer or Installer State or National Item or Installer Serial No. Province No. Board No.

Liquid Waste Recycle Duke Power Co. WL N/A 76 System Refueling Water Duke Power Co. FW N/A 54 System Auxiliary Feedwater Duke Power Co. CA N/A 73 System Residual Heat Duke Power Co. ND N/A 63 Removal System Nuclear Service Water Duke Power Co. RN N/A 60 System Chemical & Volume Duke Power Co. NV N/A 80 Control System Component Cooling Duke Power Co. KC N/A 78 System Main Feedwater Duke Power Co. CF N/A 61 System Containment Spray Duke Power Co. NS N/A 69 System Containment Duke Power Co. RV N/A 72 Ventilation Cooling Water System Safety Iniection System Duke Power Co. NI N/A 83 Diesel Generator Duke Power Co. KD N/A 47 Engine Cooling Water System Spent Fuel Cooling Duke Power Co. KF N/A 81 System Diesel Generator Duke Power Co. LD N/A 51 Engine Lube Oil System Unit 2 Duke Power Co. N/A N/A 84 McGuire Unit 2 Page 3 of 5 Outage IIEOC-16 Revision 0 Section 1 May 26,2005

i 1.2 Personnel. Equipment and Material Certifications All personnel who performed or evaluated the results of inservice inspections during the time frame bracketed by the examination dates shown on the NIS-1 Form were certified in accordance with the requirements of the 1998 Edition of ASME Section XI with the 2000 addenda including Appendix VII for ultrasonic inspections. In addition, ultrasonic examiners were qualified in accordance with ASME Section Xl, Appendix Vil, and 1995 Edition with the 1996 Addenda through the Performance Demonstration Initiative (PDI) for piping welds.

The appropriate certification records for each inspector, calibration records for inspection equipment, and records of materials used (i.e. NDE consumables) are on file at McGuire Nuclear Station or copies may be obtained by contacting the Duke Energy's Corporate Office in Charlotte, North Carolina.

The copies of the certification records for the Atlantic Group and the Washington Group inspectors can be obtained by contacting the Duke Energy's Corporate Office in Charlotte, North Carolina.

1.3 Reference Documents The following reference documents apply to the inservice inspections performed during this report period. A copy may be obtained by contacting the [SI Plan Manager at Duke Energy's Corporate Office in Charlotte, North Carolina:

1. Code Case N-460 (Applicable to items in this report where less than 100%

coverage of the required weld examination volume was achieved.) These items are identified on Run D that is located in Section 4 of this report.

2. Problem Investigation Process M-05-1947 (Covers submittal of NIS-2 Form during 2EOC-17 instead of 2EOC-1 6.)
3. RFR 03-002 (Class 1, 2 and 3 snubber examination under station technical specification)
4. RFR 01-005 (Risk Informed Inservice Inspection Program Submittal)
5. RFR 01-008 (Risk Informed ISI Alternative to Use VT-2 Instead of Volumetric Examination of Socket Welds) 1.4 Augmented and Elective Examinations Augmented and elective examination information found within this Inservice Inspection Report is not required by the ASME Section XI Code; therefore, it is exempt from ANII review, verification, and / or record certification.

McGuire Unit 2 Page 4 of 5 Outage IIEOC-16 Revision 0 Section 1 May 26, 2005

1.5 Responsible Inspection Agency The Hartford Steam Boiler Inspection and Insurance Company of Connecticut are responsible for the third party inspections required by ASME Section Xl.

Authorized Nuclear Inservice Inspector(s)

Name: J.F. Swan Employer: The Hartford Steam Boiler Inspection & Insurance Company of Connecticut Business 200 Ashford Center North Address: Suite 205 Atlanta, GA 30338-4860 (800) 417-3721 www.hsbct.com McGuire Unit 2 Page 5 of 5 Outage 1/EOC-16 Revision 0 Section 1 May 26, 2005

2.0 Third Ten-Year Interval Inspection Status The completion status of inspections required by the 1998 ASME Code Section Xl, 2000 Addenda is summarized in this section. The requirements are listed by the ASME Section Xl Examination Category as defined in Table IWB-2500-1 for Class 1 Inspections, Table IWC-2500-1 for Class 2 Inspections, and IWF-2500-1 for Class 1,2 and 3 Component Supports. Augmented Inspections are also included.

During the McGuire Third 10 Year Interval piping welds will be examined under the Risk Informed Inservice Inspection program developed in accordance with methodology contained in the Westinghouse Owners Group (WOG) Topical Report, WCAP-14572, Revision 1-NP-A. Request for Relief 01-005 was submitted to the NRC seeking approval to incorporate the Risk Informed Program into the Third 10 Year Interval [SI Plan for McGuire Unit 2. The NRC approved use of this program per SER dated June 12, 2002. Previous code examination Categories B-F, B-J, C-F-1, and C-F-2 will now be combined under the new Risk Informed Category R-A.

Class 1 Inspections Examination Description Inspections Inspections Percentage 'Deferral Category Required Completed Completed Allowed B-A Pressure Retaining Welds 15 0 00.00% Yes in Reactor Vessel B-B Pressure Retaining Welds 5 0 00.00% No in Vessels Other than Reactor Vessel .

B-D Full Penetration Welded 36 2 5.55% Partial Nozzles in Vessels Inspection Program B Reference B-F Pressure Retaining Risk Dissimilar Metal Welds in Informed Vessel Nozzles Program

._ R01. Items B-G-1 Pressure Retaining Bolting 241 35 14.52% Yes Greater than 2" In Diameter B-G-2 Pressure Retaining Bolting 14 2 14.28% No 2" and Less In Diameter McGuire Unit 2 Page 1 of 4 Outage I/EOC-16 Revision 0 Section 2 May 26, 2005

Class 1 Inspections (Continued)

Examination Description Inspections Inspections Percentage 'Deferral Category Requirted Completed Allowed Reference B-J Pressure Retaining Welds Risk No in Piping Informed Program R01. Items B-K Welded Attachments for 6 2 33.33% No Vessels, Piping, Pumps and Valves l B-L-1 Pressure Retaining Welds N/A N/A N/A Yes in Pump Casings B-L-2 Pump Casings 1 0 00.00% Yes B-M-1 Pressure Retaining N/A N/A N/A Yes Welds in Valve Bodies B-M-2 Valve Body > 4 in. 7 1 14.28% Yes Nominal Pipe Size I B-N-1 Interior of Reactor Vessel 3 0 00.00% No B-N-2 Welded Core Support 2 0 00.00% Yes Structures and Interior Attachments to Reactor Vessel B-N-3 Removable Core Support 1 0 00.00% Yes Structures _

B-O Pressure Retaining Welds 3 1 33.33% Yes InControl Rod Housings .

B-P All Pressure Retaining REFERENCE SECTION 6.0 OF THIS REPORT Components B-Q Steam Generator Tubing See Note below F-A Class I Component 58 13 22.41% No F01.01 0 Supports (Code Case N-491)

Note: Steam Generator Tubing Is examined and documented by the Steam Generator Maintenance Group of the Station Support Division as required by the Station Technical Specifications and Is not Included In this reporL 1 Deferral of Inspection to the end of the Interval as allowed by ASME Section Xl Table IWB 2500-1.

These examination categories are exempt from percentage requirements per IWB-2412 (a),

Inspection Program B.

McGuire Unit 2 Page 2 of 4 Outage 1/EOC-16 Revision 0 Section 2 May 26, 2005

Class 2 Inspections Examination Description Inspections Inspections Percentage Deferral Category Reqluired Completed Completed Allowed C-A Pressure Retaining Welds 28 3 10.71% No in Pressure Vessels . . -

C-B Pressure Retaining Nozzle 11 3 27.27% No Welds in Vessels C-C Welded Attachments for 18 3 16.66% No Vessels, Piping, Pumps and Valves C-D Pressure Retaining Bolting N/A N/A N/A N/A Greater Than 2" in Diameter Reference C-F-1 Pressure Retaining Welds Risk Informed in Austenitic Stainless Program Rol.

Steel or High Alloy Piping Items Reference C-F-2 Pressure Retaining Welds Risk Informed in Carbon or Low Alloy Program ROl.

Steel Piping Items C-G Pressure Retaining Welds 7 2 28.57% No in Pumps and Valves C-H All Pressure Retaining REFERENCE SECTION 6.0 OF THIS Components REPORT F-A Class 2 Component 229 38 16.59% No Supports F01.020 (Code Case N-491)

McGuire Unit 2 Page 3 of 4 Outage 1/EOC-16 Revision 0 Section 2 May 26, 2005

Additional Class 1, 2 and 3 Component Support Inspections Examination Description Inspections Inspections Percentage Deferral Category Required Completed Completed Allowed F-A Supports other than Piping 40 7 17.50% No F01.040 Supports Class 1, 2 & 3 F-A Component Supports

  • Inspections to be performed per Relief Request 03-002 Risk Informed Inservice Inspection Program Class I and 2 Examination Description Inspections Inspections Percentage Deferral Category Required Completed Completed Allowed R-A Piping Examinations Class 91 19 20.87 No 1 and 2 Augmented Inspections Description Percentage Complete Reactor Coolant Pump Flywheels (Item No. Series GO1.) No requirements for OUTAGE 1/EOC-16 Pipe Rupture Protection (Item No. Series G03.) No requirements for OUTAGE 1/EOC-16 RPV Head Penetration Nozzles (Item No. Series GO5.) No requirements for OUTAGE 1/EOC-16 McGuire Unit 2 Page 4 of 4 Outage V1E0-16 Revision 0 Section 2 May 26, 2005

3.0 Final Inservice Inspection Plan The final Inservice Inspection Plan shown in this section lists all ASME Section XI Class 1, Class 2, and Augmented inspections credited for this report period.

The information shown below is a field description for the reporting format included in this section of the report:

ITEM NUMBER = ASME Section Xl Tables IWB-2500-1 (Class 1), IWC-2500-1 (Class 2), IWF-2500-1 (Class 1 and Class 2 ), Augmented Requirements ID NUMBER = Unique Identification Number SYS = Component System Identification ISO / DWG NUMBERS = Location and / or Detail Drawings PROC = Examination Procedures INSP REQ = Examination Technique - Magnetic Particle, Dye Penetrant, etc.

MAT/ SCH = General Description of Material DIA / THICK = Diameter / Thickness CAL BLOCKS = Calibration Block Number COMMENTS = General and / or Detail Description McGuire Unit 2 Page 1 of 1 Outage 1EOC-16 Revision 0 Section 3 May 26, 2005

EOC 16 (

DUKE ENERGY CORPORATION C.

CATEGORY B-D, Full Penetration Welded INSERVICE INSPECTION PLAN MANAGEMENT Nozzels In Vessels - Inspection Program B Inservice Inspection Database Management System Plan Report Steam Generators (Primary Side) McGuire 2 Page 1 Inservice Inspection Plan for Interval 3 Outage 1 05/25/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG 3NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Nozzle Inside Radius Section B03.140.001 2SGA-INLET MCM 2201.01-0207 NDE-680 UT CS 0.000 50235 STEAM GENERATOR 2A INLET NOZZLE TO Circumferential NC MCM 2201.01-0216 6.500 LOWER HEAD. Y1-X2 QUADRANT. (INSIDE Class A Nozzle to RADIUS SECTION).

Head B03.140.002 2SGA-OUTLET MCM 2201.01-0207 NDE-680 UT CS 0.000 50235 STEAM GENERATOR 2A OUTLET NOZZLE TO Circumferential NC MCM 2201.01-0216 6.500 LOWER HEAD. Y2-X2 QUADRANT. (INSIDE Class A Nozzle to RADIUS SECTION).

Head Total B03.140 Items: 2 Total B03 Items: 2

EOC 16 C C DUKE ENERGY CORPORATION

(

CATEGORY B-G-1, Pressure Retaining Bolting. INSERVICE INSPECTION PLAN MANAGEMENT Greater Than 2 In. In Diameter InservIce InspectIon Database Management System Plan Report Reactor Vessel McGuire 2 Page 2 Inservice Inspection Plan for Interval 3 Outage 1 05/525005 ITEM NUMBER IDNUMBER SYS ISOIDWG NUMBERS PROC INSP REQ MATISCH DIA/THK CAL BLOCKS COMMENTS Closure Head Nuts B06.010.001 2RPV-664-32-01 MCM 2201.01-01 QAL-13 VT-1 CS 10.540 REACTOR VESSEL CLOSURE HEAD NUT.

NC MCM2201.01-0106 1.770 Class A B06.010.002 2RPV-664-32-02 MCM 2201.01-01 OAL-13 VT-1 CS 10.540 REACTOR VESSEL CLOSURE HEAD NUT.

NC MCM 2201.01-0106 1.770 Class A B06.010.003 2RPV-664-32-03 MCM 2201.01-01 OAL-13 VT-1 CS 10.540 REACTOR VESSEL CLOSURE HEAD NUT.

NC MCM 2201.01.0106 1.770 Class A B06.010.004 2RPV-664-32-04 MCM2201.01-01 OAL-13 VT-1 CS 10.540 REACTOR VESSEL CLOSURE HEAD NUT.

NC MCM 2201.01-0106 1.770 Class A B06.010.005 2RPV-664-32-05 MCM 2201.01-01 QAL-13 VT-1 CS 10.540 REACTOR VESSEL CLOSURE HEAD NUT.

NC MCM 2201.01-0106 1.770 Class A B06.010.006 2RPV-664-32-06 MCM 2201.01-01 OAL-13 VT-1 CS 10.540 REACTOR VESSEL CLOSURE HEAD NUT.

NC MCM 2201.01-0106 1.770 Class A B06.010.007 2RPV-664-32-07 MOM 2201.01-01 QAL-13 VT-1 CS 10.540 REACTOR VESSEL CLOSURE HEAD NUT.

NC MOM 2201.01-0106 1.770 Class A B06.010.008 2RPV-664-32-08 MCM2201.01-01 OAL-13 VT-1 CS 10.540 REACTOR VESSEL CLOSURE HEAD NUT.

NC MCM 2201.01-0106 1.770 Class A

EOC 16 C DUKE ENERGY CORPORATION

(

CATEGORY B-G-1. Pressure Retalninc Baitin.q INSERVICE INSPECTION PLAN MANAGEMENT Greater Than 2 In. In Diameter Inservice Inspection Database Management System Plan Report WReactor Vessel McGuire 2 Page 3 N Inservice Inspection Plan for Interval 3 Outagi a 1 05/25/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B06.010.009 2RPV-664-32-09 MCM2201.01-01 OAL-13 VT-1 CS 10.540 REACTOR VESSEL CLOSURE HEAD NUT.

NC MCM 2201.01-0106 1.770 Class A Total B06.010 Items: 9

EOC 16 C

-- .DUKE ENERGY CORPORATION CATEGORY B-G-1, Pressure Retaining Bioting, INSERVICE INSPECTION PLAN MANAGEMENT Greater Than 2 In. In Diameter Inservice Inspection Database Management System Plan Report Reactor Vessel McGuire 2 Page 4 Inservice Inspection Plan for Interval 3 Outage 1 05/25/2005 ITEM NUMBER ID NUMBER SYS ISOIDWG NUME 3ERS PROC INSP REQ MAT/SCH DIArHK CAL BLOCKS COMMENTS

    • Closure Studs, when removed 806.030.001 2RPV-664-31-01 MCM2201.01-01 PDI-UT-5 UT Cs 7.000 50501 REACTOR VESSEL CLOSURE HEAD STUD.

NC MCM 2201.01-0106 64.560 Class A B06.030.002 2RPV-664-31-02 MCM2201.01-01 PDI-UT-5 UT CS 7.000 50501 REACTOR VESSEL CLOSURE HEAD STUD.

NC MCM 2201.01-0106 64.560 Class A 806.030.003 2RPV-664-31-03 MCM2201.01-01 PDI-UT-5 UT CS 7.000 50501 REACTOR VESSEL CLOSURE HEAD STUD.

NC MCM 2201.01-0106 64.560 Class A B06.030.004 2RPV-664-31-04 MCM2201.01-01' PD1-UT-5 UT CS 7.000 50501 REACTOR VESSEL CLOSURE HEAD STUD.

NC MCM 2201.01-0106 64.560 Class A B06.030.005 2RPV-664-31-05 MCM 2201.01-01 PDI-UT-5 UT CS 7.000 50501 REACTOR VESSEL CLOSURE HEAD STUD.

NC MCM 2201.01-0106 64.560 Class A 806.030.006 2RPV-664-31-06 MCM 2201.01-01 PD1-UT-5 UT 'CS 7.000 50501 REACTOR VESSEL CLOSURE HEAD STUD.

NC MCM 2201.01-0106 64.560 Class A B06.030.007 2RPV-664-31-07 MCM 2201.01-01 PD1-UT-5 UT CS 7.000 50501 REACTOR VESSEL CLOSURE HEAD STUD.

NC MCM 2201.01-0106 64.560 Class A B06.030.008 2RPV-664-31-08 MCM2201.01-01 PD1-UT-5 UT CS 7.000 50501 REACTOR VESSEL CLOSURE HEAD STUD.

NC MCM 2201.01-0106 64.560 Class A

EOC 16 (C DUKE ENERGY CORPORATION C

CATEGORY B-G-1, Pressure Retaining Bolting. INSERVICE INSPECTION PLAN MANAGEMENT Greater Than 2 In. In Diameter Inservice Inspection Database Management System Plan Report WReactor Vessel McGuire 2 Page 5 N Inservice Inspection Plan for Interval 3 Outag ael 05152005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CA.LBLOCKS COMMENTS B06.030.009 2RPV-664-31-09 MCM 2201.01-01 PDI-UT-5 UT CS 7.000 50501 REACTOR VESSEL CLOSURE HEAD STUD.

NC MCM 2201.01-0106 64.560 Class A T- D^ln MA^ ^A _ A I Oal DUD.U3U I1em3: to

EOC 16 C (I-.-

DUKE ENERGY CORPORATION CATEGORY B-G-1. Pressure Retaining Boltinq. INSERVICE INSPECTION PLAN MANAGEMENT Greater Than 2 in. In Diameter Inservice Inspection Database Management System Plan Report WReactor Vessel McGuire 2 Page 6 Inservice Inspection Plan for Interval 3 Outage 1 05/25/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Closure Washers, Bushings ----

806.050.001 2RPV-664-33-01 MCM2201.01-01 QAL-13 VT-1 CS 10.560 REACTOR VESSEL CLOSURE HEAD WASHER.

NC MCM 2201.01-0106 1.719 Class A 806.050.002 2RPV-664-33-02 MCM 2201.01-01 QAL-13 VT-1 CS 10.560 REACTOR VESSEL CLOSURE HEAD WASHER.

NC MCM2201.0i-0106 1.719 Class A B06.050.003 2RPV-664-33-03 MCM2201.01-01 QAL-13 VT-1 CS 10.560 REACTOR VESSEL CLOSURE HEAD WASHER.

NC MCM 2201.01-0106 1.719 Class A 806.050.004 2RPV-664-33-04 MCM 2201.01-01 OAL-13 VT-1 CS 10.560 REACTOR VESSEL CLOSURE HEAD WASHER.

NC MCM 2201.01-0106 1.719 Class A B06.050.005 2RPV-664-33-05 MCM 2201.01-01 QAL-13 VT-1 CS 10.560 REACTOR VESSEL CLOSURE HEAD WASHER.

NC MCM 2201.01-0106 1.719 Class A B06.050.006 2RPV-664-33-06 MCM2201.01-01 OAL-13 VT-1 CS 10.560 REACTOR VESSEL CLOSURE HEAD WASHER.

NC MCM 2201.01-0106 1.719 Class A B06.050.007 2RPV-664-33-07 MCM2201.01-01 OAL-13 VT-1 CS 10.560 REACTOR VESSEL CLOSURE HEAD WASHER.

NC MCM 2201.01-0106 1.719 Class A B06.050.008 2RPV-664-33-08 MCM2201.01-01 OAL-13 VT-1 CS 10.560 REACTOR VESSEL CLOSURE HEAD WASHER.

NC MCM 2201.01-0106 1.719 Class A

EOC 16 DUKE ENERGY CORPORATION C'.

CATEGORY B-G-1. Pressure Retaining Bolting, INSERVICE INSPECTION PLAN MANAGEMENT Greater Than 2 In. In Diameter Inservice Inspection Database Management System Plan Report WReactor Vessel McGuire 2 Page 7 N Inservice Inspection Plan for Interval 3 Outag e 1 05/25/2005 ITEM NUMBER IDNUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAJTHK CAAL BLOCKS COMMENTS B06.050.009 2RPV-664-33-09 MCM 2201.01-01 OAL-13 VT-1 Cs 10.560 REACTOR VESSEL CLOSURE HEAD WASHER.

NC MCM 2201.01-0106 1.719 Class A Total B06.050 Items: 9

EOC 18  ;£ DUKE ENERGY CORPORATION c'

CATEGORY B-G-1, Pressure Retaining Bolting. INSERVICE INSPECTION PLAN MANAGEMENT Greater Than 2 In. In Diameter Inservice Inspection Database Management System Plan Report Steam Generat ors McGuire 2 Page 8 Inservice Inspection Plan for Interval 3 Outage 1 05/25/2005 ITEM NUMBER IDNUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Flange Surface, when connection disassembled B06.100.001 2SGA-MW-Y1-X1 MCM 2201.01-0194 OAL-13 VT-1 CS 0.000 STEAM GENERATOR 2A PRIMARY INLET NC MCM 2201.01-0126 0.000 MANWAY FLANGE SURFACE. Y1-X1 Class A QUADRANT. INSPECT WHEN CONNECTION DISASSEMBLED.

B06.100.002 2SGA-MW-X1-Y2 MCM 2201.01-0194 OAL-13 VT-1 CS 0.000 STEAM GENERATOR 2A PRIMARY OUTLET NC MCM 2201.01-0126 0.000 MANWAY FLANGE SURFACE. X1-Y2 Class A QUADRANT. INSPECT WHEN CONNECTION DISASSEMBLED.

B06.100.003 2SGB-MW-Y1-X2 MCM 2201.01-0194 QAL-13 VT-1 CS 0.000 STEAM GENERATOR 2B PRIMARY INLET NC MCM 2201.01-0127 0.000 MANWAY FLANGE SURFACE. Y1-X2 Class A QUADRANT. INSPECT WHEN CONNECTION DISASSEMBLED.

B06.100.004 2SGB-MW-X2-Y2 MCM 2201.01-0194 QAL-13 VT-1 CS 0.000 STEAM GENERATOR 2B PRIMARY OUTLET NC MCM 2201.01-0127 0.000 MANWAY FLANGE SURFACE. X2-Y2 Class A QUADRANT. INSPECT WHEN CONNECTION DISASSEMBLED.

B06.100.005 2SGC-MW-Y1-XI MCM 2201.01-0194 QAL-13 VT-1 CS 0.000 STEAM GENERATOR 2C PRIMARY INLET NC MCM 2201.01-0126 0.000 MANWAY FLANGE SURFACE. Y1-X1 Class A QUADRANT. INSPECT WHEN CONNECTION DISASSEMBLED.

B06.100.006 2SGC-MW-XI-Y2 MCM2201.01-0194 OAL-13 VT-1 CS 0.000 STEAM GENERATOR 2C PRIMARY OUTLET NC MCM2201.01-0126 0.000 MANWAY FLANGE SURFACE. X1-Y2 Class A QUADRANT. INSPECT WHEN CONNECTION DISASSEMBLED.

B06.100.007 2SGD-MW-Y1-X2 MCM 2201.01-0194 QAL-13 VT-1 CS 0.000 STEAM GENERATOR 2D PRIMARY INLET NC MCM 2201.01-0127 0.000 MANWAY FLANGE SURFACE. Y1-X2 Class A QUADRANT. INSPECT WHEN CONNECTION DISASSEMBLED.

B06.100.008 2SGD-MW-X2-Y2 MCM 2201.01-0194 QAL-13 VT-1 CS 0.000 STEAM GENERATOR 2D PRIMARY OUTLET NC MCM 2201.01-0127 0.000 MANWAY FLANGE SURFACE. X2-Y2 Class A QUADRANT. INSPECT WHEN CONNECTION DISASSEMBLED.

Total B06.100 Items: 8 Total B06 Items: 35

EOC 16 C C(

DUKE ENERGY CORPORATION c

CATEGORY B-G-2. Pressure Retaining Baitin., 2 INSERVICE INSPECTION PLAN MANAGEMENT in. And Less In Diameter Inservice Inspection Database Management System Plan Report McGuire 2 Page 9 Inservice Inspection Plan for Interval 3 Outage 1 05/25/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/rHK CAL BLOCKS COMMENTS

_ Bolts, Studs, and Nuts B07.060.004 2RCP-2D-S MCM 1201.01-120 QAL-13 VT-1 NA 2.000 REACTOR COOLANT PUMP 2D #1 SEAL GLAND NC MC-ISIN3-2553-01.00 8.000 BOLTING (12 BOLTS, PC.15). INSPECT BOLTING Class A ON ONE REACTOR COOLANT PUMP ONLY.

B07.060.008 2RCP-2D-H MCM 1201.01-120 QAL-13 VT-1 NA 1.000 REACTOR COOLANT PUMP 20 #2 SEAL NC MC-ISIN3-2553-01.00 3.250 HOUSING BOLTING (12 BOLTS, PC.66). INSPECT Class A BOLTING ON ONE REACTOR COOLANT PUMP ONLY.

Total B07.060 Items: 2 Total B07 Items: 2

EOC 16 C A.,

DUKE ENERGY CORPORATION

(

CATEGORY B-K, Welded Attachments For INSERVICE INSPECTION PLAN MANAGEMENT Vessels, Piping, Pumps, And Valves Inservice Inspection Database Management System Plan Report NPressure Vessels McGuire 2 Page 10 N Inservice Inspection Plan for Interval 3 Outage 1 05/25/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT(SCH DIANTHK CAL BLOCKS COMMENTS Welded Attachments I B10.010.004 2PZR-W13C MCM 2201.01-16 NDE-25 MT CS 4.000 WELDED ATTACHMENT. PRESSURIZER NC MC-ISIN3-2553-02.00 NDE-35 4.000 SEISMIC LUG TO SHELL W-X QUADRANT.

Class A MCM 1201.01-0048 Seismic Lug to PT MAY BE USED INPLACE OF MT IF Shell NECESSARY Total B10.010 Items: 1

EOC 16 'C C, DUKE ENERGY CORPORATION C.

CATEGORY B-K, Welded Attachments For INSERVICE INSPECTION PLAN MANAGEMENT Vessels, Piping, Pumps, And Valves Inservice Inspection Database Management System Plan Report McGuire 2 Page 11 Inservice Inspection Plan for Interval 3 Outage 1 05/25/2005 ITEM NUMBER ID NUMBER SYS ISO/DW( ' NUMBERS PROC INSP REQ MATISCH DIAITHK CAL BLOCKS COMMENTS Welded Attachments I B10.020.001 2MCR-NC-4791 MCSRD-2NC-202/sht. 1 NDE-35 PT NA 3.000 WELDED ATTACHMENT. INSPECT WITH Mech Snubber NC MC-ISIN3-2553-02.00 0.500 F01.010.020C.

Class A 2MCR-NC-4791 Total B130.020 Items: I Total B10 Items: 2

EOC 16 IC DUKE ENERGY CORPORATION C

CATEGORY B-M-2. Valve Body INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report McGuire 2 Page 12 Inservice Inspection Plan for Interval 3 Outage 1 05/2512005 ITEM NUMBER IDNUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MATISCH DIANTHK CAL BLOCKS COMMENTS Valve Body, Exceeding NPS 4

  • B12.050.001C 2NC-3 MCFI-2NC53 OAL-14 VT-3 Ss 6.000 6 CROSBYRELIEFVALVE. INSPECT ONE OF NC MC-ISIN3-2553-02.00 0.000 THE FOLLOWING VALVES: 2NC-1, 2NC-2, OR Class A MCM 1205.09-0001 2NC-3 ONLY IFVALVE ISDISASSEMBLED FOR MAINTENANCE, REPAIR, OR VOLUMETRIC EXAMINATION.

Total B12.050 Items: 1 I Total B12 Items: I

EOC 16 ;5 C DUKE ENERGY CORPORATION CATEGORY B-N-1, Interior Of Reactor Vessel INSERVICE INSPECTION PLAN MANAGEMENT Inservice InspectIon Database Management System Plan Report Reactor Vessel McGuire 2 Page 13 Inservice Inspection Plan for Interval 3 Outage 1 0512512005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIANTHK CAL BLOCKS COMMENTS Vessel Interior B13.010.001 2RPV-INTERIOR MCM 2201.01-0001 QAL-14 VT-3 SS 0.000 REACTOR VESSEL INTERIOR. AREAS TO BE NC MC-ISIN3-2553-01.00 0.000 EXAMINED SHALL INCLUDE THE SPACES Class A ABOVE AND BELOW THE REACTOR CORE THAT ARE MADE ACCESSIBLE FOR EXAMINATION BY REMOVAL OF COMPONENTS DURING NORMAL REFUELING OUTAGES. INSPECT EACH INSPECTION PERIOD.

THIS EXAMINATION WAS PERFORMED FOR THE SECOND INTERVAL PER RFR 03-004.

EXAMINATION ALSO PERFORMED FOR 2EOC-1 6/OUTAGE 1, WILL REPORT BUT WILL NOT COUNT FOR PERCENTAGE PURPOSE.

EXAMINATION WILL BE PERFORMED 2EOC-17/OUTAGE 2 AND WILL REPORT FOR PERCENTAGES AT THAT TIME.

Total 313.010 Items: 11 313 Items:

Total B13 Items: 1

EOC 16 *11 C-DUKE ENERGY CORPORATION

(

CATEGORY B-O. Pressure Retalning Welds In INSERVICE INSPECTION PLAN MANAGEMENT Control Rod Housings Inservice Inspection Database Management System Plan Report Reactor Vessel McGuire 2 Page 14 Inservice Inspectlon Plan for Interval 3 Outage 1 05/25/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUN ABERS PROC INSP REQ MAT/SCH DIANTHK CAL BLOCKS COMMENTS

B14.010.017 2RPV-CRDM.71 MCM 2201.01-20/sht.7 NDE-35 PT SS-Inconel 4.000 CRD HOUSING WELD. (PERIPHERAL)

NC MCM 2201.01-0001 0.642 Class A MC-ISIN3-2553-01.00 Adapter to Housing Body Total B14.010 Items: I Total B14 Items: 1

EOC 16B(

PeDUKE C

ENERGY CORPORATION C

CATEGORY C-A. Pressure Retaininq Welds In INSERVICE INSPECTION PLAN MANAGEMENT Pressure Vessels Inservice Inspection Database Management System Plan Report

  • Head Circumferential Welds McGuire 2 Page 15
  • Inservice Inspection Plan for Interval 3 Outage 1 05/2512005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS C01.020.090 2RCHPSS-SH-3 MCM 1201.04-272 NDE-3630 UT SS 12.000 50313 RECIPROCATING CHARGING PUMP SUCTION Circumferential NV MC-ISIN3-2554-03.00 0.375 STABILIZER.

Class B Shell to Upper Head C01.020.091 2RCHPSS-SH-2 MCM 1201.04-272 NDE-3630 UT SS 12.000 50313 RECIPROCATING CHARGING PUMP SUCTION Circumferential NV MC-ISIN3-2554-03.00 0.375 STABILIZER.

Class B Shell to Lower Head Total C01.020 Items: 2

EOC 16 C C-DUKE ENERGY CORPORATION CATEGORY C-A. Pressure Retaining Welds In INK SERVICE INSPECTION PLAN MANAGEMENT Pressure Vessels Insei vice Inspection Database Management System Plan Report EMubesheet-toRShell Weld McGuire 2 Page 16 0 Incservice Inspection Plan for Interval 3 Outage 1 05/25/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS C01.030.001 2SGA-W65 MCM 2201.01-0207 NDE-620 UT CS 0.000 5135230 STEAM GENERATOR 2A. DEPENDING UPON Circumferential SM MC-ISIN3-2591-01.01 See Com 3.687 50236A EXAMINER'S QUALIFICATIONS PROCEDURE Class B Tubesheet to PDI-UT-6 MAY BE USED IN LIEU OF PROCEDURE Shell NDE-620.

Total C=1.030 Items: 3 Total C01 Items: 3

EOC 16 C( CJ DUKE ENERGY CORPORATION CATEGORY C-B. Pressure Retaininq Nozzle INSERVICE INSPECTION PLAN MANAGEMENT Welds In Vessels Inservice Inspection Database Management System INozzles Without Relnforcinq Plate In Vessels >

W112 In. Nom. Thickness McGuire 2 Inservice Inspection Plan for Interval 3 Outage 1 Plan Report Page 17 05/25/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAJTHK CAL BLOCKS COMMENTS Nozzle-to-Shell (Nozzle to Head or Nozzle to Nozzle) Weld *'

C02.021.001 2SGA-W258 MCM 2201.01-0207 NDE-820 UT CS 16.000 5139385 STEAM GENERATOR 2A FEEDWATER NOZZLE.

Circumferential SM MC-ISIN3-2591-01.01 NDE-640 4.125 Class B MCM 2201.01-0159 Nozzle to Steam Drum C02.021.001A 2SGA-W258 MCM 2201.01-0207 NDE-25 MT CS 16.000 STEAM GENERATOR 2A FEEDWATER NOZZLE.

Circumferential SM MC-ISIN3-2591-01.01 4.125 Class B MCM 2201.01-0159 Nozzle to Steam Drum C02.021.002 2SGC-W259 MCM 2201.01-0207 NDE-820 UT CS 6.000 5139385 STEAM GENERATOR 2C AUXILLIARY Circumferential SM MC-ISIN3-2591-01.01 NDE-640 4.125 FEEDWATER NOZZLE.

Class B MCM 2201.01-0160 Nozzle to Steam Drum C02.021.002A 2SGC-W259 MCM 2201.01-0207 NDE-25 MT CS 6.000 STEAM GENERATOR 2C AUXILLIARY Circumferential SM MC-ISIN3-2591-01.01 4.125 FEEDWATER NOZZLE.

Class B MCM 2201.01-0160 Nozzle to Steam Drum Total C02.021 Items: 4

Class B MCM 2201.01-0159 Nozzle to Steam Drum Total C02.022 Items: 1 Total C02 Items: 5

EOC 16 A (9 DUKE ENERGY CORPORATION CATEGORY C-C, Welded Attachments For INSERVICE INSPECTION PLAN MANAGEMENT Vessels. PiDing. Pumps, And Vialves Insdrvice Inspection Database Management System Plan Report Pressure Vessels McGuire 2 Page 18 Inservice Inspection Plan for Interval 3 Outage 1 05/25/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

ND MC-ISIN3-2561-01.00 0.750 WELDED ATTACHMENT. REFERENCE DRAWING Class B MCM 1201.06-48 MC-1220-32.

C03.010.007 2ELDHX-SUPPORT MCM 1201.06-0010 NDE-25 MT CS 0.000 EXCESS LETDOWN HX SUPPORT. WELDED NV MC-ISIN3-2554-01.02 NDE-35 0.375 ATTACHMENT.

Class B PT MAY BE USED IN PLACE OF MT IF NECESSARY Total C03.010 Items: 2

EOC 16 C DUKE ENERGY CORPORATION C.

CATEGORY C-C, Welded Attachments For INSERVICE INSPECTION PLAN MANAGEMENT Vessels, Piping, Pumps, And Valves Inservice Inspection Database Management System Plan Report McGuire 2 Page 19 Inservice Inspection Plan for Interval 3 Outage I 05/25/2005 ITEM NUMBER ID NUMBER SYS ISO/DWCGNUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS AAA&

Welded Attachments **-*

C03.020.024 2MCA-ND-5311 MCSRD-2FW-350/sht. 4 NDE-35 PT SS 12.000 WELDED ATTACHMENT. INSPECT WITH Mech Snubber ND MC-ISIN3-2561-01.00 0.375 F01.020.103C.

Class B 2MCA-ND-5311 Total C03.020 Items: 1 Total C03 Items: 3 I

EOC 16 C DUKE ENERGY CORPORATION

(

CATEGORY C-G. Pressure Retalninq Welds In INSERVICE INSPECTION PLAN MANAGEMENT Pumps And Valves Inservice Inspection Database Management System Plan Report McGuire 2 Page 20 Inservice Inspection Plan for Interval 3 Outage 1 05/25/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUWABERS PROC INSP REQ MATISCH DIArTHK CAL BLOCKS COMMENTS IValve BodvWelds C06.020.003A 2NV0804-1 MCM 1205.00-0362 NDE-35 PT SS 4.000 ITEM # 9J-226. INSPECT ONE VALVE INTHIS Circumferential NV MC-ISIN3-2554-03.01 0.878 GROUP (3A-3C) PER INTERVAL.

Class B Valve Body to Valve Body C06.020.005A 2ND0030A-1 MCM 1205.00-0455 NDE-35 PT SS 8.000 ITEM # 9D-227. INSPECT ONE VALVE INTHIS Circumferential ND MC-ISIN3-2561-01.00 0.722 GROUP (5A-only valve) PER INTERVAL Class B Valve Body to Valve Body Total COS.020 Items: 2 Total COS Items: 2

EOC 16 DUKE ENERGY CORPORATION (3

CATEGORY D-A. Welded Attachments For INSERVICE INSPECTION PLAN MANAGEMENT Vessels, Piping. Pumps, And Valves Inservice Inspection Database Management System Plan Report

  • Pressure, Vessels McGuire 2 Page 21 Inservice Inspection Plan for Interval 3 Outage 1 05/25/2005 N

ITEM NUMBER ID NUMBER SYS ISOIDWG NUMBERS PROC INSP REQ MATISCH DIA/THK CAL BLOCKS COMMENTS

  • Welded Attachments * **

D01.010.004 2KFHX-SUPPORT-2A MCM 1201.06-0027 QAL-13 VT-1 NA 0.000 FUEL POOL COOLING HX 2A SUPPORT.

Rigid Restraint KF MC-ISIN3-2570-01.01 0.250 WELDED ATTACHMENT.

Class C MC-1220-32 Total D01.010 Items: 1 Total D01 Items: I

EOC 16 C C,'

DUKE ENERGY CORPORATION

(

CATEGORY F-A, Supports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report

.Class 1 PIDIng SUPPorts McGuire 2 Page 22 Inservice Inspection Plan for Interval 3 Outage 1 05/25/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

  • "A", One-Dlrectlonal, "B", Multi-Directional, "C", Thermal Movement
  • F01.010.001C 2MCR-NC-4500 MCSRD-2NC-201/sht. 1 QAL-14 VT-3 NA 14.000 Spring Hgr NC 0.000 Class A F01.010.006C 2MCR-NC-4253 MCSRD-2NC-210/sht. 1 OAL-14 VT-3 NA 2.000 Mech Snubber NC 0.000 Class A F01.010.007C 2MCR-NC-4254 MCSRD-2NC-210/sht. 1 QAL-14 VT-3 NA 2.000 Mech Snubber NC 0.000 Class A F01.010.014A 2MCR-NC-4120 MCSRD-2NI-203/sht. 1 OAL-14 VT-3 NA 10.000 Rigid Support NC 0.000 Class A F01.010.016C 2MCR-NC-4083 MCSRD-2NI-215/sht. 1 OAL-14 VT-3 NA 1.500 Mech Snubber NC 0.000 Class A F01.010.017C 2MCR-NC-4163 MCSRD-2NV-202/sht. 2 OAL-14 VT-3 NA 1.500 Mech Snubber NC 0.000 Class A F01.010.018A 2MCR-NC-4093 MCSRD-2NV-204/sht. 1 QAL-14 VT-3 NA 2.000 Rigid Support NC 0.000 Class A F01.010.020C 2MCR-NC-4791 MCSRD-2NC-202/sht. 1 QAL-14 VT-3 NA 3.000 INSPECT WITH B10.020.001 Mech Snubber NC 0.500 Class A

EOC 16 C C, (

DUKE ENERGY CORPORATION CATEGORY F-A. Supports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Ilass I PPlngq Supports McGuire 2 Page 23 Inservice Inspection Plan for Interval 3 Outage 1 05/25/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DINATHK CAL BLOCKS COMMENTS F01.010.076A 2MCR-NI-4949 MCSRD-2ND-2011sht. 2 OAL-14 VT-3 NA 8.000 Rigid Support NI 0.000 Class A F01.010.077C 2MCR-NI-4943 MCSRD-2ND-201/sht. 2 OAL-14 VT-3 NA 8.000 Mech Snubber NI 0.000 Class A F01.010.078B 2MCR-NI-4654 MCSRD-2ND-201/sht. 2 OAL-14 VT-3 NA 8.000 Rigid Restraint NI 0.000 Class A F01.010.093C 2MCR-NI-4661 MCSRD-2ND-201/sht. 2 QAL-14 VT-3 NA 8.000 Hyd Snubber NI 0.000 Class A F01.010.115C 2MCR-NV-4007 MCSRD-2NV-207/sht. 1 OAL-14 VT-3 NA 2.000 Mech Snubber NV 0.000 Class A Total F01.010 Items: 13

EOC 16 C C.

DUKE ENERGY CORPORATION CATEGORY F-A. Supports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report

  • Class 2 Piping Supports McGuire 2 Page 24 Inservice Inspection Plan for Interval 3 Outage 1 05/25/2005 ITEM NUMBER IDNUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MATISCH DIA/THK CAL BLOCKS COMMENTS
        • "NA", One-Directional, "B", Multl-Dlrectional, "Cm, Thermal Movement ****

F01.020.003B 2MCA-CA-H15 MCSRD-2CAM/sht. 2 QAL-14 VT-3 NA 6.000 Rigid Restraint CA 0.000 Class B F01.020.006C 2MCR-CA.H94 MCSRD-2CAO/sht. 1 OAL-14 VT-3 NA 6.000 Mech Snubber CA 0.000 Class B F01.020.013A 2MCA-CA-H14 MCSRD-2CAM/sht. 1 QAL-14 VT-3 NA 6.000 Rigid Support CA 0.000 Class B F01.020.015B 2MCA-CA-H131 MCSRD-2CAP/sht. 1 QAL-14 VT-3 NA 4.000 RIgid RestraInt CA 0.000 Class B F01.020.016C 2MCA-CA-H21 MCSRD-2CAM/sht. 1 QAL-14 VT-3 NA 4.000 Hyd Snubber CA 0.000 Class B F01.020.019C 2MCA-CA-H142 MCSRD-2CAP/sht. 1 QAL-14 Vr-3 NA 6.000 Hyd Snb/Mec Snb CA 0.000 Class B F01.020.101B 2MCA-ND-5211 MCSRD-2FW-350/sht. 3 OAL-14 VT-3 NA 12.000 Rigid Restraint ND 0.000 Class B F01.020.102A 2MCA-ND-5307 MCSRD-2FW-350/sht. 4 QAL-14 VT-3 NA 18.000 Rigid Support ND 0.000 Class B

EOC 16 C i-. C-'

DUKE ENERGY CORPORATION C

CATEGORY F-A, Supports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report

  • CQass 2 PlIlnL SuPorts McGuire 2 Page 25 Inservice Inspection Plan for Interval 3 Outage 1 05/25/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS FOt.020.103C 2MCA-ND-5311 MCSRD-2FW-350/sht. 4 QAL-14 VT-3 NA 12.000 INSPECT WITH C03.020.024.

ND 0.375 (LIMIT STOP)

Class B F01.020.125C 2MCA-ND-5204 MCSRD-2FW-350/sht. 3 QAL-14 VT-3 NA 12.000 (LIMIT STOP)

ND 0.000 Class B F011.020.132A 2MCA-ND-5506 MCSRD-2ND-350/sht. 5 QAL-14 VT-3 NA 8.000 Rigid Support ND 0.125 Class B F01.020.133A 2MCA-ND-5802 MCSRD-2ND0350/sht. 6 QAL-14 VT-3 NA 8.000 Rigid Support ND 0.000 Class B F01.020.158B 2MCR-NI-4821 MCSRD-2NI-208/sht.1 QAL-14 VT-3 NA 4.000 Rigid Restraint Ni 0.000 Class B F01.020.159B 2MCR-NI-4825 MCSRD-2NI-208/sht.1 QAL-14 VT-3 NA 2.000 Rigid Restraint NI 0.000 Class B F01.020.160A 2MCR-NI-4787 MCSRD-2NI-209/sht. 1 OAL-14 VT-3 NA 4.000 Rigid Support Ni 0.000 Class B F01.020.161A 2MCR-NI-4772 MCSRD-2NI-209/sht. 1 QAL-14 VT-3 NA 4.000 Rigid Support NI 0.000 Class B F01.020.168B 2MCR-NI-4899 MCSRD-2NI-213/sht. 1 QAL-14 VT-3 NA 3.000 Rigid Restraint NI 0.000 Class B

EOC 16 C , , C_

DUKE ENERGY CORPORATION CATEGORY F-A, SupPorts INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report WIass 2 PIPIna SuPports McGuire 2 Page 26 Inservice Inspection Plan for Interval 3 Outage 1 05/25/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MATISCH DIAITHK CAL BLOCKS COMMENTS F01.020.169C 2MCR-NI14896 MCSRD-2NI-213/sht. 1 QAL-14 VT-3 NA 3.000 Mech Snubber NI 0.000 Class B F01.020.170A 2MCR-NI-4892 MCSRD-2NI-213/sht. 1 QAL-14 VT-3 NA 3.000 Rigid Support . NI 0.000 Class B F01.020.171C 2MCR-NI-4134 MCSRD-2NI-215/sht. 1 OAL-14 VT-3 NA 3.000 Mech Snubber NI 0.000 Class B F01.020.175B 2MCA-NI-5036 MCSRD-2NI-350/sht. 3 QAL-14 VT-3 NA 4.000 Rigid Restraint NI 0.000 Class B F01.020.176B 2MCA-NI-5718 MCSRD-2NI-350/sht. 3 OAL-14 VT-3 NA 4.000 Rigid Restraint NI 0.000 Class B F01.020.1788 2MCA-NI-5806 MCSRD-2NV-353/sht. 3 OAL-14 VT-3 NA 4.000 Rigid RestraInt NI 0.000 Class B F01.020.183A 2MCR-NI.4950 MCSRD-2ND-201/sht. 2 OAL-14 VT-3 NA 12.000 Rigid Support NI 0.000 Class B F01.020.184A 2MCA-NI-5045 MCSRD-2ND-362/sht.1 QOAL.14 VT-3 NA 6.000 Rigid Support NI 0.000 Class B F01.020.190A 2MCR-NI-4765 MCSRD-2NI-209/sht. 1 QAL-14 VT-3 NA 4.000 Rigid Support NI 0.000 Class B

EOC 16 C C' C DUKE ENERGY CORPORATION CATEGORY F-A, Supports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report ECIass 2 Plplng Suports McGuire 2 Page 27 Inservice Inspection Plan for Interval 3 Outage 1 05/25/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH D1A/THK CAL BLOCKS COMMENTS F01.020.191A 2MCR-NI-4060 MCSRD-2NI-211/sht. 1 QAL-14 VT-3 NA 2.000 Rigid Support NI 0.000 Class B F01.020.202B 2MCR-NS-4515 MCSRD-2NS-201/sht. I QAL-14 VT-3 NA 8.000 Rigid Restraint NS 0.000 Class B F01.020.203B 2MCR-NS-4566 MCSRD-2NS-202/sht. 1 QAL-14 VT-3 NA 8.000 Rigid Restraint NS 0.000 Class B F01.020.204B 2MCR-NS-4551 MCSRD-2NS-202/sht. 2 OAL-14 VT-3 NA 8.000 Rigid Restraint NS 0.000 Class B F01.020.205B 2MCR-NS-4555 MCSRD-2NS-202/sht. 2 OAL-14 VT-3 NA 8.000 Rigid Restraint NS 0.000 Class B F01.020.228A 2MCA-NS-5207 MCSRD-2NS-352/sht. 1 OAL-14 VT-3 NA 10.000 Rigid Support NS 0.125 Class B F01.020.428C 2MCA-SM-H24 MCSRD-2SMAlsht. 2 OAL-14 VT-3 NA 36.000 Mech Snubber SM 0.000 Class B F01.020.429C 2MCA-SM-H69 MCSRD-2SMA/sht. 4 OAL-14 VT-3 NA 36.000 Mech Snubber SM 0.000 Class B F01.020.477B 2MCA-SV-H9 MCSRD-2SVA/sht. 1 QAL-14 VT-3 NA 6.000 Rigid Restraint SV 0.000 Class B

EOC 16 C C DUKE ENERGY CORPORATION CATEGORY F-A. SuDports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report CIass 2 Plplni Supports McGuire 2 Page 28 InservIce Inspection Plan for Interval 3 Outage 1 05/2512005 ITEM NUMBER IDNUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MATISCH DIA/THK CAL BLOCKS COMMENTS F01.020.503C 2MCR-VQ-4507 MCSRD-2VQ 202/sht. 1 OAL-14 VT-3 NA 6.000 Mec Snb/Spr Hgr Vo 0.000 Class B F01.020.505B 2MCR-VQ-4544 MCSRD-2VQ-201/sht. 1 QAL-14 VT-3 NA 6.000 Rigid Restraint VQ 0.000 Class B F01.020.525B 2MCR-WL.4061 MCSRD-2WL-2071sht. 1 OAL-14 VT-3 NA 6.000 Rigid Restraint WL 0.000 Class B Total F01.020 Items: 38

EOC 16 C C-;.

DUKE ENERGY CORPORATION C

CATEGORY F-A. Sup orts INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Cilass 3 Piping Supports McGuire 2 Page 29 Inservice Inspection Plan for Interval 3 Outage I 05/25/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • "A", One-Directional, "B", Multi-Directional, "C", Thermal Movement ****

F01.030.001B 2MCA-CA-5160 MCSRD-2CA-351/sht. 1 OAL-14 VT-3 NA 8.000 Rigid Restraint CA 0.000 Class C F01.030.002A 2MCA-CA-5210 MCSRD-2CA-351/sht. 2 QAL-14 VT-3 NA 8.000 Rigid Support CA 0.000 Class C F01.030.003A 2MCA-CA-5208 MCSRD-2CA-351/sht. 1 OAL-14 VT-3 NA 8.000 Rigid Support CA 0.000 Class C F01.030.004A 2MCA-CA-5554 MCSRD-2CA-356/sht.1 QAL-14 VT-3 NA 6.000 Rigid Support CA 0.000 Class C F01.030.050A 2MCR-KC-4022 MCSRD-2KC-201/sht. 1 OAL-14 VT-3 NA 8.000 Rigid Support KC 0.000 Class C F01.030.051C 2MCR-KC-4557 MCSRD-2KC-201/sht. 1 QAL-14 VT-3 NA 6.000 Mech Snubber KC 0.218 Class C F01.030.052A 2MCR-KC-4054 MCSRD-2KC-202/sht. 1 QAL-14 Vr-3 NA 6.000 Rigid Support KC 0.000 Class C F01.030.053A 2MCR-KC-4057 MCSRD-2KC-202/sht. 2 QAL-14 VT-3 NA 8.000 Rigid Support KC 0.000 Class C

EOC 16 C DUKE ENERGY CORPORATION CATEGORY F-A. Supports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report MCIass Pllnq 3 SUPports McGuire 2 Page 30 Inservice Inspection Plan for Interval 3 Outage 1 05/25/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIArrHK CAL BLOCKS COMMENTS F01.030.054B 2MCR-KC-4503 MCSRD-2KC-202/sht. 2 QAL-14 VT-3 NA 8.000 Rigid Restraint KC 0.000 Class C F01.030.055A 2MCA-KC-3327 MCSRD-2KC-351/sht. 1 OAL-14 VT-3 NA 6.000 Rigid Support KC 0.000 Class C F01.030.056A 2MCA-KC-3328 MCSRD-2KC-351/sht. 2 OAL-14 VT-3 NA 8.000 Rigid Support KC 0.216 Class C F01.030.061A 2MCA-KC-3285 MCSRD-2KC-351/sht. 3 QAL-14 V`T-3 NA 10.000 Rigid Support KC 0.000 Class C F01.030.1111B 2-MCA-LD-3071 MCSRD-2LD-351/sht. 1 OAL-14 VT-3 NA 6.000 Rigid Restraint LD 0.000 Class C F01.030.112A 2-MCA-LD-3079 MCSRD-2LD-3521sht. 2 OAL-14 VT-3 NA 6.000 Rigid Support LD 0.000 Class C F01.030.113C 2-MCA-LD-3010 MCSRD-2LD-352/sht. 1 OAL-14 VT-3 NA 6.000 Spring Hgr LD 0.000 Class C F01.030.191B 2MCA-RV-H503 MCSRD-2RN-364/sht. 1 OAL-14 VT-3 NA 6.000 Rigid Restraint RV 0.000 Class C Total F01.030 Items: 16

EOC 16 C DUKE ENERGY CORPORATION

('

CATEGORY F-A, Supports INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report SunDDorts Other Than Plping Supports McGuire 2 Page 31 Inservice Inspection Plan for Interval 3 Outage 1 O0 5/2005 N

ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Class 1, 2, and 3 **-*

F01.040.002B 2PZR-LUGS MCM 2201.01-15 OAL-14 VT-3 NA 0.000 PRESSURIZER SUPPORT LUGS. REFERENCE Rigid Restraint NC MC-ISIN3-2553-02.00 0.000 DRAWING MC-1070.22.

Class A MCM 2201.01-16 F01.040.008B 2NSP-SUPPORT-2A MC 1680 QAL-14 VT-3 NA 0.000 CONTAINMENT SPRAY PUMP 2A SUPPORT.

Rigid Restraint NS MC-ISIN3-2563-01.00 0.000 Class B F01.040.009B 2NSHX-SUPPORT-2A MCM 1201.06.0025 OAL-14 VT-3 NA 0.000 CONTAINMENT SPRAY HX 2A SUPPORT. SINCE Rigid Restraint NS MC-ISIN-2563-01.00 0.750 'HX Al & 'HX B' ARE OF DIFFERENT DESIGN, Class B MCM 1201.06-093 WILL EXAMINE BOTH. OTHER DRAWING MC-1220-32 F01.040.010B 2REGHX-SUPPORT MCM 1201.06.0015 QAL-14 VT-3 NA 0.000 REGENERATIVE HX SUPPORT.

Rigid Restraint NV MC-ISIN3-2554-01.02 0.250 Class B MCM 1201.06-69 F01.040.034B 2DG-SUPPORT-2A MCM 1301.00-02 OAL-14 VT-3 NA 0.000 DIESEL GENERATOR ENGINE 2A Rigid Restraint KD MC-ISIN3-2609-01.00 0.000 SUPPORT/LUBE OIL PUMP 2A.

Class C F01.040.038B 2ELDHX-SUPPORT MCM 1201.06-0010 QAL-14 VT-3 NA 0.000 EXCESS LETDOWN HX SUPPORT.

Rigid Restraint NV MC-ISIN3-2554-01.02 0.375 Class B F01.040.039B 2NSHX-SUPPORT-2B MCM 1201.06-0090 QAL-14 VT-3 NA 0.000 CONTAINMENT SPRAY HX 2B SUPPORT. SINCE Rigid Restraint NS MC-ISIN3-2563-01.00 0.750 *HX A' & 'HX B ARE OF DIFFERENT DESIGN Class B MC 1220-32 WILL EXAMINE BOTH.

Total F01.040 items: 7 Total F01 Items: 74

EOC 18 C DUKE ENERGY CORPORATION CATEGORY AUG. Augmented Inspections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Augarnented Examination McGuire 2 Page 32 Inservice Inspection Plan for Interval 3 Outage 1 05/2512005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

-*** Pipe Rupture Protection G03.001.001 2NC2FW16-1 MCFI-2NC16 NDE-600 UT SS 10.000 See Comm AUGMENTED EXAMINATION. REFERENCE Circumferential NC MC-ISIN3-2553-01.00 PDI-UT-2 1.000 DOCUMENT SRG-78-001 REV.2 (DISTRIBUTION Class A See Comm Elbow to CODE MADM-257). *SEE SECTION 8 FOR Nozzle CALIBRATION BLOCK REQUIREMENTS.

DEPENDING UPON THE EXAMINERS QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY BE USED IN LIEU OF PROCEDURE NDE.600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.

G03.001.001A 2NC2FW16-1 MCFI-2NC16 NDE-35 PT SS 10.000 AUGMENTED EXAMINATION. REFERENCE Circumferential NC MC-ISIN3-2553-1.00 1.000 DOCUMENT SRG-78-001 REV.2 (DISTRIBUTION Class A Elbow to CODE MADM-257).

Nozzle Total G03.001 Items: 2 Total G03 Items: 2

EOC 16 C C-DUKE ENERGY CORPORATION CATEGORY R-A, Risk Informed Piping INSERVICE INSPECTION PLAN MANAGEMENT Examinations Inservice Inspection Database Management System IClass 1 and 2 Pipina Welds McGuire 2 Inservice Inspection Plan for Interval 3 Outage 1 Plan Report Page 33 05/25/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIANTHK CAL BLOCKS COMMENTS Elements Subject to Thermal Fatigue ***-

R01.011.013 2NC2F2-8C MCFI-2NC40 NDE-600 UT SS 2.000 See Comm SEGMENT NC-017. *SEESECTION 8 FOR Circumferential NC MC-ISIN-2553-01.00 PDI-UT-2 0.344 50217 CALIBRATION BLOCK REQUIREMENTS.

Class A See Comm Pipe to DEPENDING UPON THE EXAMINERS Pipe Cap QUALIFICATIONS, PROCEDURE PDIUT-2 MAY BE USED INLIEU OF PROCEDURE NDE-600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.

R01.011.019 2NC2FW22-3 MCFI-2NC22 NDE-600 UT SS 6.000 See Comm SEGMENT NC-033 Circumferential NC MC-ISIN-2553-01.00 PDI-UT-2 0.719 50211 *SEE SECTION 8 FOR CALIBRATION BLOCK Class A See Cormm Elbow to REQUIREMENTS.

Pipe DEPENDING UPON THE EXAMINERS QUALIFICATIONS, PROCEDURE PDI.UT-2 MAY,:'

BE USED INLIEU OF PROCEDURE NDE-600. IF-PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.

R01.011.020 2NC2FW22-16 MCFI-2NC22 NDE-600 UT SS 14.000 See Comm SEGMENT NC-034. *SEE SECTION 8 FOR Circumferential NC MC-ISIN-2553-01.00 PDI-UT-2 1.250 50213 CALIBRATION BLOCK REQUIREMENTS.

Class A See Comm Elbow to DEPENDING UPON THE EXAMINERS Tee QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY BE USED IN LIEU OF PROCEDURE NDE-600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.

R01.011.021 2NC2FW24-6 MCFI-2NC24 NDE-600 UT SS 6.000 See Comm SEGMENT NC-035. 'SEE SECTION 8 FOR Circumferential NC MC-ISIN-2553-01.00 PDI-UT-2 0.719 50211 CALIBRATION BLOCK REQUIREMENTS.

Class A See Comm Pipe to DEPENDING UPON THE EXAMINERS Elbow QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY BE USED IN LIEU OF PROCEDURE NDE-600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.

R01.01 1.026 2NC2FW31-8 MCFI-2NC31 NDE-600 UT SS 4.000 See Comm SEGMENT NC-092. *SEE SECTION 8 FOR Circumferential NC MC-ISIN-2553-01.00 PDI-UT-2 0.237 50438 CALIBRATION BLOCK REQUIREMENTS.

Class B See Comm Reducer to DEPENDING UPON THE EXAMINERS Pipe QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY BE USED IN LIEU OF PROCEDURE NDE-600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.

EOC 16 C DUKE ENERGY CORPORATION CATEGORY R-A. Risk Informed Piping INSERVICE INSPECTION PLAN MANAGEMENT Examinations InservIce Inspection Database Management System Plan Report

.Class 1 and 2 Piping Welds McGuire 2 Page 34 Inservice Inspection Plan for Interval 3 Outage 1 05/25/2005 ITEM NUMBER ID NUMBER SYS ISOIDWG NUMBERS PROC INSP REQ MATISCH DIAITHK CAL BLOCKS COMMENTS R01.011.051 2NDP73-1 MCFI-2ND7 NDE-600 UT SS 8.000 See Comm SEGMENT ND-008A. *SEE SECTION 8 FOR Circumferential ND MC-ISIN-2561-01.00 PDI-UT-2 0.250 CALIBRATION BLOCK REQUIREMENTS.

Class B See Comm Elbow to DEPENDING UPON THE EXAMINERS Pipe QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY BE USED IN LIEU OF PROCEDURE NDE-600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.

R01.011.052 2ND2FW15-3 MCFI-2ND15 NDE-600 UT SS 8.000 See Comm SEGMENT ND-009A. *SEESECTION 8 FOR Circumferential ND MC-ISIN-2561-01.00 PDI-UT-2 0.250 CALIBRATION BLOCK REQUIREMENTS.

Class B See Comm Pipe to DEPENDING UPON THE EXAMINERS Elbow QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY BE USED IN LIEU OF PROCEDURE NDE-600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.

R01.011.061 2NIP23-1 MCFI-2NI2 NDE-600 UT Ss 4.000 See Comm SEGMENT NI-030A. *SEE SECTION 8 FOR Circumferential NI MC-ISIN-2562-03.00 PDI-UT-2 0.337 50436 CALIBRATION BLOCK REQUIREMENTS.

Class B See Comm Pipe to DEPENDING UPON THE EXAMINERS Elbow QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY-`

BE USED INLIEU OF PROCEDURE NDE-600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.

R01.011.063 2N12F608 MCFI-2N121 NDE-600 UT SS 18.000 See Comm SEGMENT NI-059. *SEE SECTION 8 FOR Circumferential NI MC-ISIN-2562-03.01 PDI-UT-2 0.250 CALIBRATION BLOCK REQUIREMENTS.

Class B See Comm Pipe to DEPENDING UPON THE EXAMINERS Elbow QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY BE USED INLIEU OF PROCEDURE NDE-600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.

R01.011.064 2NI2F611 MCFI-2N121 NDE-600 UT SS 18.000 See Comm SEGMENT NI-059. *SEE SECTION 8 FOR Circumferential NI MC-ISIN-2562-03.01 PDI-UT-2 0.250 CALIBRATION BLOCK REQUIREMENTS.

Class B See Comm Elbow to DEPENDING UPON THE EXAMINERS Elbow QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY BE USED IN LIEU OF PROCEDURE NDE-600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.

EOC 16 (* C  ; (C_

DUKE ENERGY CORPORATION CATEGORY R-A, Risk Informed Piping INSERVICE INSPECTION PLAN MANAGEMENT Examinatlons Inservice Inspection Database Management System Plan Report Class I and 2 Plolnq Welds McGuire 2 Page 35 Inservice Inspection Plan for Interval 3 Outage 1 0512512005 FN & ln ed ITEM NUMBER ID NUMBER SYS ISOIDWG NUMBERS PROC INSP REQ MAT/SCH DINATHK CAL BLOCKS COMMENTS R01.011.065 2NI2F616 MCFI-2N121 NDE-600 UT SS 18.000 See Comm SEGMENT NI-060. *SEE SECTION 8 FOR Circumferential NI MC-ISIN-2562-03.01 PDI-UT-2 0.250 CALIBRATION BLOCK REQUIREMENTS.

Class B See Comm Elbow to DEPENDING UPON THE EXAMINERS Pipe QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY BE USED IN LIEU OF PROCEDURE NDE-600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.

R01.011.066 2NI2F619 MCFI-2NI21 NDE-600 UT SS 18.000 See Comm SEGMENT NI-060. *SEE SECTION 8 FOR Circumferential NI MC-ISIN-2562-03.01 PDI-UT-2 0.250 CALIBRATION BLOCK REQUIREMENTS.

Class B See Comm Elbow to DEPENDING UPON THE EXAMINERS Elbow QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY BE USED IN LIEU OF PROCEDURE NDE-600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.

R01.011.067 2N12F234 MCFI-2NI6 NDE-600 UT SS 3.000 See Comm SEGMENT NI-061A. *SEE SECTION 8 FOR Circumferential NI MC-ISIN-2562-01.00 PDI-UT-2 0.438 50225 CALIBRATION BLOCK REQUIREMENTS.

Class B See Comm Reducer to DEPENDING UPON THE EXAMINERS Elbow QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY;-

BE USED INLIEU OF PROCEDURE NDE-600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.

R01.011.068 2NIP59-2 MCFI-2NI6 NDE-600 UT SS 3.000 See Comm SEGMENT NI-061A. *SEE SECTION 8 FOR Circumferential NI MC-ISIN-2562-01.00 PDI-UT-2 0.438 50225 CALIBRATION BLOCK REQUIREMENTS.

Class B See Comm Pipe to DEPENDING UPON THE EXAMINERS Pipe QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY BE USED INLIEU OF PROCEDURE NDE-600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.

R01.011.069 2N12FW27-13 MCFI-2NI27 NDE-600 UT SS 3.000 See Comm SEGMENT NI-062A. *SEE SECTION 8 FOR Circumferential NI MC-ISIN-2562-01.00 PDI-UT-2 0.438 50225 CALIBRATION BLOCK REQUIREMENTS.

Class B See Comm Pipe to DEPENDING UPON THE EXAMINERS Elbow QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY BE USED IN LIEU OF PROCEDURE NDE-600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.

EOC 16 (

DUKE ENERGY CORPORATION C-CATEGORY R-A. Risk Informed Piping INSERVICE INSPECTION PLAN MANAGEMENT Examinations Inservice Inspection Database Management System Plan Report

.Class 1 and 2 Piplng Welds McGuire 2 Page 36 Inservice Inspection Plan for Interval 3 Outage 1 05/25/2005 InWed ITEM NUMBER IDNUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MATISCH DIA/THK CAL BLOCKS COMMENTS R01.011.070 2N12FW27-24 MCFI-2NI27 NDE-600 UT SS 3.000 See Comm SEGMENT NI-062A. *SEE SECTION 8 FOR Circumferential NI MC-ISIN-2562-01.00 PDI-UT-2 0.438 50225 CALIBRATION BLOCK REQUIREMENTS.

Class B See Comm Reducer to DEPENDING UPON THE EXAMINERS Pipe QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY BE USED IN LIEU OF PROCEDURE NDE-600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.

R01.011.071 2N12FW27-15 MCFI-2NI27 NDE-600 UT SS 3.000 See Comm SEGMENT NI-063A. *SEE SECTION 8 FOR I Circumferential NI MC-ISIN-2562-01.00 PDI-UT-2 0.438 50225 CALIBRATION BLOCK REQUIREMENTS.

Class B See Comm Tee to DEPENDING UPON THE EXAMINERS Reducer QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY BE USED INLIEU OF PROCEDURE NDE-600. IF PDI-UT-2 IS USED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.

R01.011.130 2NV2FW180-48 MCFI-2NV180 NDE-600 UT SS 4.000 See Comm SEGMENT NV-002B. *SEE SECTION 8 FOR Circumferential NV MC-ISIN-2554-03.00 PDI-UT-2 0.237 CALIBRATION BLOCK REQUIREMENTS.

Class B See Comm Elbow to DEPENDING UPON THE EXAMINERS Elbow QUALIFICATIONS, PROCEDURE PDI-UT-2 MAY BE USED IN LIEU OF PROCEDURE NDE-600. IF PDI-UT-2 ISUSED CALIBRATION BLOCK PDI-UT-2-M MUST BE USED.

Total R01.011 Items: 18 Elements Subject to Corrosive, Erosive, or Cavitation Wastage R01.013.001 2RV2FW30-17 MCFI-2RV30 NDE-946 UT CS 12.000 STEP SEGMENT RV-001.

Circumferential RV MC-ISIN-2604-03.00 0.375 WEDGE EXAMINE A 1 FT. LENGTH OF PIPE AT WELD TO Class B Elbow to DETERMINE WALL THKS. EXAMINE 6 INCHES Pipe EACH SIDE OF WELD, MARK IN 1 INCH GRID Total R01.013 Items: 1 Total R01 Items: 19

K> 4.0 Results of Inspections Performed The results of each examination shown in the final Inservice Inspection Plan (Section 3 of this report) are included in this section. The completion date and status for each examination are shown. All examinations revealing reportable indications and any corrective action required as a result are described in further detail in Subsections 4.1 and 4.2. Corrective measures performed and limited examinations are described in further detail in Subsections 4.3 and 4.4.

The information shown below is a field description for the reporting format included in this section of the report:

ITEM NUMBER = ASME Section Xl Tables IWB-2500-1 (Class 1), IWC-2500-1 (Class 2), IWF-2500-1 (Class 1 and Class 2),

Augmented Requirements ID NUMBER = Unique Identification Number SYSTEM = Component System Identification INSP DATE - Date of Examination INSP STATUS = CLR Clear REC Recordable REP Reportable INSP LIMITED - Indicates inspection was limited.

Coverage obtained is listed.

GEO REF Y Yes (Geometric Reflector N No applies only to UT)

RFR (Relief Request) Y Yes N No COMMENTS - General and for Detail Description McGuire Unit 2 Page 1 of 2 Outage 1VEOC-16 Revision 0 Section 4 May 26,2005

4.1 Reportable Indications There were no reportable indications for the examinations associated with this report period.

4.2 Corrective Action Corrective action is action taken to resolve flaws and relevant Conditions, including supplemental examinations, analytical evaluations, repair / replacement activities, and corrective measures. There were no corrective actions for the examinations associated with this report period.

4.3 Corrective Measures Corrective measures are actions (such as maintenance) taken to resolve relevant conditions, but not including supplemental examinations, analytical evaluations, and repair / replacement activities. Any corrective measures performed for examinations associated with this report period will be shown on the examination data sheets which are on file at the Duke Energy Corporate Office in Charlotte, North Carolina.

4.4 Limited Examinations Limitations (i.e., 90% or less of the required examination coverage obtained) identified for examinations associated with this report period are shown below. A relief request will be submitted to seek NRC acceptance of the limited coverage. This information will be on file at the Duke Energy Corporate Office in Charlotte, North Carolina.

Item Number Relief Request Serial Numbers R01.01 1.013 87.00%

R01 .011.069 89.80%

R01.01 1.071 89.80%

McGuire Unit 2 Page 2 of 2 Outage VJEOC-16 Revision 0 Section 4 May 26, 2005

DUKE ENErF( )RPORATION QUALITY ASSURANME TECHNICAL SERVICES In-Service Inspection Database Management System Run D EOC 16 Page 1 McGuire 2 Inservice Inspection Listing Plant: McGuire 2 Interval 3 Outage 1 05/25/2005 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS B03.140.001 2SGA-INLET NC 03/11/2005 CLR N B03.140.002 2SGA-OUTLET NC 03/11/2005 CLR N B06.010.001 2RPV-664-32-01 NC 03/1712005 CLR N B06.010.002 2RPV-664-32.02 NC 03/1712005 CLR N B06.010.003 2RPV-664-32-03 NC 03/17/2005 CLR N B06.010.004 2RPV-664-32-04 NC 03/17/2005 CLR N B06.010.005 2RPV-664-32-05 NC 03/17/2005 CLR N B06.010.006 2RPV-664-32-06 NC 03/17/2005 CLR N B06.010.007 2RPV-664-32-07 NC 03/1712005 CLR N B06.010.008 2RPV-664-32-08 NC 03/17/2005 CLR N B06.010.009 2RPV-664-32-09 NC 03/17/2005 CLR N B06.030.001 2RPV-664-31-01 NC 03/17/2005 CLR N B06.030.002 2RPV-664-31-02 NC 03/17/2005 CLR N B06.030.003 2RPV-664-31-03 NC 03/1712005 CLR N B06.030.004 2RPV-664-31-04 NC 03/1712005 CLR N B06.030.005 2RPV-664-31 -05 NC 03/17/2005 CLR N B06.030.006 2RPV-664-31-06 NC 03/17/2005 CLR N B06.030.007 2RPV-664-31-07 NC 03/17/2005 CLR N B06.030.008 2RPV-664-31-08 NC 03/1712005 CLR N 806.030.009 2RPV-664-31-09 NC 03/1712005 CLR N B06.050.001 2RPV-664-33-01 NC 03/17/2005 CLR N B06.050.002 2RPV-664-33-02 NC 03/17/2005 CLR N B06.050.003 2RPV-664-33-03 NC 03/1712005 CLR N 806.050.004 2RPV-664-33-04 NC 03/17/2005 CLR N B06.050.005 2RPV-664-33-05 NC 03/1712005 CLR N B06.050.006 2RPV-664-33-06 NC 03/1712005 CLR N B06.050.007 2RPV-664-33-07 NC 03/17/2005 CLR N B06.050.008 2RPV-664-33-08 NC 03/17/2005 CLR N B06.050.009 2RPV-664-33-09 NC 03/17/2005 CLR N B06.100.001 2SGA-MW-Y -Xl NC 04/01/2005 CLR N B06.100.002 2SGA-MW-X1-Y2 NC 03/31/2005 CLR N B06.100.003 2SGB-MW-Y1-X2 NC 03/3112005 CLR N B06.100.004 2SGB-MW-X2-Y2 NC 03/31/2005 CLR N B06.100.005 2SGC-MW-Y1 -Xl NC 03/31/2005 CLR N B06.100.006 2SGC-MW-X1-Y2 NC 03/31/2005 CLR N B06.100.007 2SGD-MW-Y1-X2 NC 03/31/2005 CLR N

DUKE ENEIIJ )RPORATION OUALITY ASSURAI -TECHNICALSERVICES In-Service Inspection Database Management System Run D EOC 16 McGuire 2 Inservice Inspection Listing Page 2 Plant: McGuire 2 05/25/2005 Interval 3 Outage 1 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS B06.100.008 2SGD-MW-.X2-Y2 NC 03/31/2005 CLR N N B07.060.004 2RCP-2D-S NC 03/22/2005 CLR N N B07.060.008 2RCP-2D-H NC 03/22/2005 CLR N N B10.010.004 2PZR-W13C NC 03/21/2005 CLR N N B10.020.001 2MCR-NC-4791 NC 03/10/2005 CLR N N B12.050.001C 2NC-3 NC 03/22/2005 CLR N N B13.010.001 2RPV-INTERIOR NC 03/20/2005 CLR N N NOTE THIS ITEM EXAMINED EOC-1 6 FOR SECOND INTERVAL, ALSO SHOWN HERE BUT NOT COUNTED IN PERCENTAGE TOTALS, WILL BE REEXAMINED EOC-17 FOR THIRD INTERVAL REPORTING.

B14.010.017 2RPV-CRDM-71 NC 03/12/2005 CLR N C01.020.090 2RCHPSS-SH-3 NV 02/21/2005 CLR N C01.020.091 2RCHPSS-SH-2 NV 02/21/2005 CLR ... N C01.030.001 2SGA-W65 SM 03/14/2005 CLR 95.13% N C02.021.001 2SGA-W258 SM 03118/2005 CLR 95.81% N C02.021.001A 2SGA-W258 SM 03/18/2005 CLR N C02.021.002 2SGC-W259 SM 03/21/2005 CLR 95.81% N C02.021.002A 2SGC-W259 SM 03/21/2005 CLR N C02.022.001 2SGA-W258 SM 03/18/2005 CLR ... N C03.010.001 2NDHX-SUPPORT-2A ND 03/01/2005 CLR 96.40% N C03.010.007 2ELDHX-SUPPORT NV 03/21/2005 CLR N C03.020.024 2MCA-ND-5311 ND 03/15/2005 CLR N C06.020.003A 2NV0804-1 NV 02/24/2005 CLR N C06.020.005A 2ND003OA-1 ND 03/01/2005 CLR N D01.010.004 2KFHX-SUPPORT-2A KF 02/01/2005 CLR N F01.010.001C 2MCR-NC-4500 NC 03/08/2005 CLR N F01.010.006C 2MCR-NC-4253 NC 03/08/2005 CLR N F01.010.007C 2MCR-NC-4254 NC 03/08/2005 CLR N F01.010.014A 2MCR-NC-4120 NC 03/08/2005 CLR N F01.010.016C 2MCR-NC-4083 NC 03/08/2005 CLR N F01.010.017C 2MCR-NC-4163 NC 03/08/2005 CLR N F01.010.018A 2MCR-NC-4093 NC 03/08/2005 CLR N F01.010.020C 2MCR-NC-4791 NC 03/08/2005 CLR N F01.010.076A 2MCR-NI-4949 NI 03/05/2005 CLR N F01.010.077C 2MCR-NI-4943 NI 03/08/2005 CLR N F01.010.078B 2MCR-NI-4654 NI 03/08/2005 CLR N F01.010.093C 2MCR-NI-4661 NI 03/08/2005 CLR N

DUKE ENE%( )RPORATION QUALITY ASSURAI;E TECHNICAL SERVICES In-Servico Inspection Database Management System Run D EOC 16 McGuire 2 Inservice Inspection Listing Page 3 Plant: McGuire 2 05125/2005 Interval 3 Outage 1 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS F01.010.115C 2MCR-NV-4007 NV 03108/2005 CLR F01.020.003B 2MCA-CA-H15 CA 02/03/2005 CLR F01.020.006C 2MCR-CA-H94 CA 03/08/2005 CLR F01.020.013A 2MCA-CA-H14 CA 02/03/2005 CLR F01.020.0155B 2MCA-CA-H1 31 CA 02/03/2005 CLR F01.020.016C 2MCA-CA-H21 CA 02/03/2005 CLR F01.020.019C 2MCA-CA-H142 CA 02/03/2005 CLR F01.020.101 B 2MCA-ND-5211 ND 02/01/2005 CLR F01.020.102A 2MCA-ND-5307 ND 02/01/2005 CLR F01.020.103C 2MCA-ND-5311 ND 02/01/2005 CLR F01.020.125C 2MCA-ND-5204 ND 02101/2005 CLR F01.020.132A 2MCA-ND-5506 ND 02/01/2005 CLR F01.020.133A 2MCA-ND-5802 ND 02101/2005 CLR F01.020.158B 2MCR-NI-4821 NI 03/05/2005 CLR F01.020.159B 2MCR-NI-4825 NI 03/05/2005 CLR F01.020.160A 2MCR-NI-4787 NI 03/05/2005 CLR F01.020.161A 2MCR-NI-4772 NI 03/05/2005 CLR F01.020.168B 2MCR-NI-4899 NI 03/05/2005 CLR F01.020.169C 2MCR-NI-4896 NI 03/05/2005 CLR F01.020.170A 2MCR-NI-4892 NI 03/05/2005 CLR F01.020.171C 2MCR-NI-4134 NI 03/05/2005 CLR F01.020.175B 2MCA-NI-5036 Ni 02/10/2005 CLR F01.020.176B 2MCA-NI-5718 NI 02/10/2005 CLR F01.020.178B 2MCA-NI-5806 NI 02/10/2005 CLR F01.020.183A 2MCR-NI-4950 NI 03/05/2005 CLR F01.020.184A 2MCA-NI-5045 NI 02110/2005 CLR F01.020.190A 2MCR-NI-4765 NI 03/05/2005 CLR F01.020.191A 2MCR-NI-4060 NI 03/05/2005 CLR F01.020.202B 2MCR-NS-4515 NS 03/04/2005 CLR F01.020.203B 2MCR-NS-4566 NS 03/04/2005 CLR F01.020.204B 2MCR-NS-4551 NS 03/04/2005 CLR F01.020.205B 2MCR-NS-4555 NS 03/04/2005 CLR F01.020.228A 2MCA-NS-5207 NS 02/10/2005 CLR F01.020.428C 2MCA-SM-H24 SM 02/03/2005 CLR F01.020.429C 2MCA-SM-H69 SM 02/03/2005 CLR F01.020.477B 2MCA-SV-H9 SV 02/03/2005 CLR

DUKE ENErK )RPORATION QUALITY ASSURAIC TECHNICAL SERVICES (

In-Service Inspection Database Management Syitem Run D EOC 16 Page 4 McGuire 2 Inservice Inspection Listing Plant: McGuire 2 05/2512005 Interval 3 Outage 1 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS F01.020.503C 2MCR-VO-4507 Va 03/04/2005 CLR N N F01.020.505B 2MCR-VQ-4544 Va 03/04/2005 CLR N N F01.020.525B 2MCR.WL-4061 WL 03/04/2005 CLR N N F01.030.001 B 2MCA-CA-5160 CA 02/08/2005 CLR N N F01.030.002A 2MCA-CA-5210 CA 02/08/2005 CLR N N F01.030.003A 2MCA-CA-5208 CA 02/08/2005 CLR N N F01.030.004A 2MCA-CA-5554 CA 02/08/2005 CLR N N F01.030.050A 2MCR-KC-4022 KC 03/05/2005 CLR N N F01.030.051C 2MCR-KC-4557 KC 03/05/2005 CLR N N F01.030.052A 2MCR-KC-4054 KC 03/05/2005 CLR N N F01.030.053A 2MCR-KC-4057 KC 03/05/2005 CLR N N F01.030.054B 2MCR-KC-4503 KC 03/05/2005 CLR N N F01.030.055A 2MCA-KC-3327 KC 02/10/2005 CLR N N F01.030.056A 2MCA-KC-3328 KC 02110/2005 CLR N N F01.030.061A 2MCA-KC-3285 KC 02/10/2005 CLR N N F01.030.1111B 2-MCA-LD-3071 LD 02/01/2005 CLR N N F01.030.112A 2-MCA-LD-3079 LD 02/01/2005 CLR N N F01.030.113C 2-MCA-LD-3010 LD 02101/2005 CLR N N F01.030.191 B 2MCA-RV-H503 RV 02/0212005 CLR N N F01.040.002B 2PZR-LUGS NC 03/10/2005 CLR N N F01.040.008B 2NSP-SUPPORT-2A NS 02/01/2005 CLR N N F01.040.009B 2NSHX-SUPPORT-2A NS 02101/2005 CLR N N F01.040.01 OB 2REGHX-SUPPORT NV 03/11/2005 CLR N. N F01.040.034B 2DG-SUPPORT-2A KD 02/01/2005 CLR N N F01.040.038B 2ELDHX.SUPPORT NV 03/10/2005 CLR N N F01.040.039B 2NSHX-SUPPORT-2B NS 02/01/2005 CLR N N G03.001.001 2NC2FW16-1 NC 03/10/2005 CLR N N G03.001.001A 2NC2FW16-1 NC 03/10/2005 CLR N N R01.011.013 2NC2F2-8C NC 03/2212005 CLR 87.00% N Y R01.011.019 2NC2FW22-3 NC 03/13/2005 CLR N N R01.011.020 2NC2FW22-16 NC 03/2212005 CLR N N R101.011.021 2NC2FW24-6 NC 03/13/2005 CLR 90.80% N N R01.011.026 2NC2FW31-8 NC 02/25/2005 CLR N N R01.011.051 2NDP73-1 ND 02/25/2005 CLR N N R01.011.052 2ND2FW15-3 ND 02/25/2005 CLR N N R01.011.061 2NIP23-1 NI 02121/2005 CLR N N

DUKE ENEr T)RPORATION QUALITY ASSURANV= TECHNICAL SERVICES In-Service Inspection Database Management System Run D EOC 16 Page 5 McGuire 2 Inservice Inspection Listing Plant: McGuire 2 Interval 3 Outage 1 05/25/2005 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS R01.011.063 2N12F608 NI 02/25/2005 CLR .-- N N R01.011.064 2NI2F611 NI 02/25/2005 CLR N N R101.011.065 2N12F616 NI 02/25/2005 CLR - N N R01.011.066 2N12F619 NI 02/25/2005 CLR - N N R01.011.067 2NI2F234 NI 02124/2005 CLR - N N R01.011.068 2NIP59-2 NI 02/24/2005 CLR - N N R01.011.069 2NI2FW27-13 NI 03/22/2005 CLR 89.80% N Y R01.011.070 2NI2FW27-24 NI 03/22/2005 CLR --- N N R01.011.071 2NI2FW27-15 NI 03/22/2005 CLR 89.80% N Y R101.011.130 2NV2FW180-48 NV 02/21/2005 CLR - N N R101.013.001 2RV2FW30-17 RV 02/25/2005 CLR - N N

5.0 Owner's Report for Repair / Replacement Activities As required by the applicable code, records of Class 1 and Class 2 Repair and Replacement work is included on NIS-2 forms in this section.

One item was determined to have had work performed outside this report period.

Listed below is the information to address these issues.

I Work Order Number =Signoff Date/EOC I PIP Number WO 98646189 EOC-17 M-05-1947 The NIS-2 forms included in this section were completed for work performed during this report period. The individual work request documents and manufacturers' data reports are on file at McGuire Nuclear Station.

5.1 Class 1 and 2 Preservice Examinations As required by the applicable code, Preservice Inspection (PSI) Examinations were performed on ISI Class 1 and 2 items during this report period. All Class 1 and 2 PSI examination data listed below is on file in the McGuire Nuclear Station QA Vault.

Work Order Identification Number 151 Type of Inspection Class 98411032 2-SM-VA-101 B VT-1 98482980 2-ND-VA-67B B VT-1 98535892 2MCR-NV-4058 B VT-3 98620710 RN Piping Welds RN2FW57-1 B PT and RN2F-1515 98620711 RV Piping Welds RV2FW40-7 B PT and RV2FW21-36 98620713 RV Piping Weld RV2FW21 -30 B PT and RV2FW20-20 98620714 RN Piping Weld RN2F-1489 B PT 98629559 2SV-1 9 B VT-1 98645487 2-BB-VA-2, 2MCA-BB-5489 B VT-1, VT-3 98647610 NV Piping B VT-1 98650088 2KC-VA-479 B VT-1 98652410 2-NC-VA-3 A VT-1 98652770 2-MCR-NC-SG-A B VT-3 98653117 2-NM-VA-92 B VT-1 98653418 2-SM-VA-1 B VT-1 98653463 2A Steam Generator/Replace B VT-1 Stud 98653488 2-NS-HX-0003/Replace B VT-1 Bolting McGuire Unit 2 Page 1 of 2 Outage VEOC-16 Revision 0 Section 5 May 26, 2005

Work Order Identification Number ISI Type of Inspection

._ Class 98656568 NS Piping/Repair Welds B PT 98656569 NS Piping/Repair Welds B PT.

98663764 2NV-93, 2MCR-NV-4217 B VT-1, VT-3 98664169 2NV-156 B VT-i 98665743 2MCR-NV-4379, 2MCR-NV- A VT-3 4380 98670826 2NV-10 B VT-1 98674357 2NV-477 B VT-1 98674358 2NV-476 B VT-i 98684559 2-NI-VA-334 B VT-i 98701859 2-SM-VA-7 B VT-I 98709187 2MCA-NV-7011 B VT-3 98709192 2MCA-SM-H283 B VT-3 98709198 2MCR-CF-H402 B VT-3 98709200 2MCA-SM-H73 B VT-3 98709201 2MCA-FW-5180 B VT-3 98709207 2MCA-SM-H102 B VT-3 98709210 2MCA-NV-7020 B VT-3 98709302 2KC-479 B VT-i 98716703 2NI-171 A VT-i 98718214 2MCR-NI-4528 B VT-3 98718216 2MCR-NC-4253 A VT-3 McGuire Unit 2 Page 2 of 2 V. Outage l/EOC-16 Revision 0 Section 5 May 26, 2005

C- FORM NIS-2 OWNER'S RiJRT FOR REPAIR I REPLACEMENT ACTIViTY As Required By The Provisions Of The ASME Code Section X1 C

1. Owner Address: Duke Power Comoanv Ia. Date Agril 10. 2005 0 526 S. Church Street. Charlotte. NC 28201-1006 Sheet 1 of L
2. Plant Address: McGuire Nuclear Station 12700 --iaaers FernvRoad. Huntersvi le. NC 28078 2a. Unit: .01 02 03 OShared (specify Units__
3. Work Performed By- Duke Power Comoanv 3a. Work Order #:, 98411032 Address: 526 S. Church Street. Charlotte NC 28201-1006 Repir OrOaon Job #

Type Code Symbol Stamp: WA Authorization No. WA Expiration Date: NWA 3b. NSM or MM #: ME200260

4. (a) Identification of System: SM - Main Steam 4. (b) Class of System: B
5. (a) Applicable Construction Code: ASMEJI 197_ Edition, Summer and Winter Addenda, N/A Code Cases (b) Appflcable Edition of Section XI Utilized for Repair/ Replacement Acthivty 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Components:

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Componert Narme of Mfg Mfg Serial No. Naional Board No. Other idecatlon Year BuN Corred. RemOved, or ASME Code Stamped

._. Installed (yes or no)

A 0 Repaired, 0No 2-SM-VA-1 01 Kerotest TM5-5 12302 N/A 1996 T Replaced,

. 0Replacement E Yes B 0 Repaired, 0 No 2=SM-VA-101 Kerotest DAP7-3 32103 N/A 1981 0 Replaced,

___El Replacement 1 Yes C 0 Repaired, 0 No 03Replaced,

_ 0 Replacement 0 Yes D 0 Repaired, 0 No 0 Replaced,

_3 0Replacement 0Yes E 0 Repaired, 0 No 03Replaced, O3 Replacement 0 Yes F 0Repaired, 0 No 0Replaced,

. . . . 0Replacement 0Yes Page 1 of 2

Form NiS-2 (Back)

NOTE: Supplementai sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Cut out valve and replaced disc
8. Tests Conducted:Hydrostatic E Pneumatic E Nom. Operating Press. 1 Other O ExemptO Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure pSig Test Temp. OF
9. Remarks Test performed per MP/O/A/7700/045 (Applicable Manufacturers Data Reports to be attached)

CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date N/A Signed XDeF L Grass J rQA Tech Specialist Date /O ow CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT bave In the components described In this Owner's Report during the period

,.3 = to . o1 and state that to the best of my knowledge and belief, the Owner hds perormed examinations and taken corrective measures described In this Owners Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.

A r^v rome F Swan Commissions NC1524.N-I

  • Inspector' re National Board, State, Province and Endorsements i/ Dateq ot£>

Page 2 of 2

As Required by the Provisions ofi iite ASME Code, Section 111Div. 1 1. eOr i

_P.1 , _u~.JA..J5f _5XJh~.9 -5r_

1. Manufactured by J Heon+/-PhoA, fi lder E) aeadddress ol N"CcW11ni;iarHolder)
2. Manufacturedfor Dhike I'On, C;nlhgXntnl% 1P.0. Ik)x 32307 C(harlotte. North CQirol.in. 2823.2

`

(Narno and Address of PurchaseI Ot Ownerl

3. Locationotinstallation Cat-tl3xt Nttw. ier Stntion Netmjwt, South Carolinma MNOM&no n AaareSSI
4. Pump or Valve - valvc . Nominal Inlet Size 2_ _ Outlet Size 2_-

. (inch) (inch) la) Model No.. (b) N Certificate Holder's 1c) Canadian Series No. Serial Registration Id)Drawing 11) Nat'l. (gl Year or Typo No. No. No. to) Class Bd. No. Built rk tE A D_ 2 tu 1. rcl r% nxrN^A_ A 0- t t

,9p11 r3 lan

11) I. I fl I III .A I. M , _ I-- - * . * .JIc w (2)

')

(4)

(5)

(0)

(7)

(a)

(9)

(10)

5. SO mIct1 d It Eas which equiAent desinedi (Brief description of service forwhceqimnwadsge)

.6. Desigo Conditions P72: psi fiqn0 .. F or Valve Pressure Class (1) lPressure) (Temperature)

7. Cold Working Pressure 3996 psi at 100F.
8. Pressure Retaining Pieces

.Mark No. Material Spec. No. Manufacturer Remarks I I I in) Castincs

. I II I I I fb) Forgings rY-ntP. .. ... F316 McWilliamrs [or__ _ _

F.A1 05I9J Svf S 11 intr2s rorQ.e . -

I _ _ _ _ _ _I_ . I all

,-, Itr mant 9..~ hJ rtt

.- W.I..-..u..T WI -.

d -.*--I,.. .

  • Suppleme.ental shorts in form of lists. sketches or drawings may be u-ed provided t1) citceis 8.112- x 11. 12J information ir' Itoms 1. 2 and 5 on this Data Report is included on each sheet. and (31 eacli shuct is numbored and nlumnber of shoets Is recorded at top of this form. I 10nMl This torn 4E000371 nay lc nbltnind trom tle Order Dcep.. ASMI 345 E. .7th St.. Ice.sYork,N.Y. 10017

Markx No. - Material Spec. No. - - , Manutacturor 1`1MUrK6, P

.tc) Bolting ____.-

(d)Other Parts DISC-JAR SA479, TyrP 316 -Ca_-,enter WNNET--EAL -- SA4179 'ITEC i- fiy ;trl.

1).~ Hyrsai.et59 75 pi i9. Hydrostatkctest 5994 psi. DiskDifferential tstpressure 2735 pal.

r *1 CERTIFICATE OF COMPLIANCE We certify that ltho statements made in this report are correct and that this purnp or valve. conforms to the rules of conistractlon of the ASME Code for Nuclear Power Plant Compononts. Section Ill, Div. I.. Edition 1974 summer 1974 ________19__

Addendsa 1986 , Code CasO No. 1D . a 81 Signed Kerotest ianufacturinq Coro. hy g e 9p a IN Certillcate-Holder)1 Our ASME Certificate of Authorization No. 1902 to use the N Xpires 4 583 (Ni (0oatl CERTiFICAilON OF DESIGN Design Intorration on file etKerotest KMufacturin.q Corp., Pitt~sbur, PA Stress analysis report (Class ronly) on file at. Kerotest Mmanufacturing Corp. :

Design spocifications certified by A11

.R E. Miller PE Sate N. C. -ieg. No. 4237 Stressanalysiscertifi'dbyli Rn. G. Visalli PEState.- P. A. Reg. No. 19068-E (1)Signature not required. List name only.

N CERTIFICATE OF SHOP INSPECTION

1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Pen lsvlvaniin and employed by I-IS I&'. C(XIPANY of HAcTfIl), ON'NECTICUT have inspected the pump, or valve, described in this Data Report on

- 9 19_, and state that to thc best olmy knowledge and belief. the NCertificate Holder has con-structed this pump, or valve, in accordance with the AS.ME Code. Section Ill.

By signing this ceotificale. neither the Inspector nor his employer makes any warranty. expressed or implied, concerning Ihs equipm ent described In thiv Data Report. Furthermore. neithler the Inspector nor his emplover shalt be lihlo in any A mantmr for any personal Injury or property damage or a lbss of any kind arising fromn or connected wilh this inspection.

Datc 9 &jZ/Sf

_~,p~ .3 _. Commissions _X45 773 /_$1 (&'

(Inspect) -INati lSd.. Sloth. Pov. acid No.)

IC FORM NIS-2 OWNER'S RLRT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI C

1. Owner Address: Duke Power Comoanv ia. Date March 27. 2005 526 S.Church Street. Charlotte. NC 28201-1006 Sheet 1 of I
2. Plant Address: McGuire Nuclear Station  ;

12700 Hasers Ferrv Road. Huntersville, NC 28078 2a. Unit: 01 E32 033 OShared (specify Units; )

3. Work Performed By: Duke Power Comoanv 3a. Work Order #: 98482980 Address: 526 S. Church Street. Chatiotte NC 28201-1006 Repair Oraillon Job #

Type Code Symbol Stamp: WA Authorization No. NIA Expiration Date: WA 3b. NSM or MM #:- N/A

4. (a) Identification oiSystem: NDD- Residual Heat Removal 4. (b) Class of System: B
5. (a) Applicable Construction Code: ASME il 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification OT Uomponents Repaired or Replaced and Replacement Com ronents:

l Column 1 Column 2 - Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 l Name of Component Name of Mtg l Mg Serlal No. National Board No. Oier Identffication Year Built Repaired, Replaced. or ASME Code Stamped

_ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _R eplacem ent (Wesor no)

A . 0 Repaired, 0No 2-ND-VA-67B Kerotest§ MB3-10 9851 N/A N/A e Replaced,

, - 0Replacement l Yes B 0l Repaired, 0 No 03Replaced, O0Replacement 0Yes C 0 Repaired, 0 No 0 Replaced,

. 0 3 Replacement 0Yes D 0.Repaired, 0 No 03Replaced,

-  : 0 3 Replacement 0Yes E . - 0 Repaired, 0No 03Replaced,

- 0 3 Replacement 0Yes F 03Repaired,. 0 No 03Replaced,,

O0Replacement 0Yes Page 1 of 2 Revision 7

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this' form.

7. Description of Replaced disc
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. El Other 0 Exempto Pressure . - psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks Test performed per task 9 of this work order (visual)

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass Jr., OA Tech Specialist Date Owner o0wviers Designee, Title p

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by IS CT nsppcte4Ahe components described In this Owner's Report during the period Iave

. ~/L> to . ~.; and state that to the best of my knowledge and belief, the Owner has p rformed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.- -

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

ome F Swan Commissions NC1524. N-I nspecto? National Board, State, Province and Endorsements Date Page 2 of 2 Revision 7

k FORM NIS-2 OWNER'S REC-QAT FOR REPAIRS OR REPLACEMENTS C As Required By The Provisions Of The ASME Code Section Xl

  • 1. Owner Address: Duke Power Comoany ia. Date 04/08/2005

- 526 S. Church Street. Charlotte. NC 28201-1006 Sheet _1_ of 1

2. Plant Address: McGuire Nuclear Station S 12700 Hagers Ferry Road. Huntersville. NC 28078 I 2a. Unit: 01 02 03 OShared (specify Units '
3. Work Performed By: Duke Power Comoanv 3a. Work Order#: 98535892-07 Address: 526 S.Church Street. Charlotte NC 28201-1 006 Repair Organlzatl Job #

Type Code Symbol Stamp: NIA Authorization No. NIA Expiration Date: N/A 3b. NSM or MM #: N/A

4. (a) Identification of System: NV 4. (b) Class of System: B
5. (a) Applicable Construction Code: ASME il 19Z1 Edition, Summer and Winter Addenda, /A Code Cases (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements: 1998.2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Components Repaired or Replaced and Replacement Coin onents: - -,__

Column 1 . Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component. Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

_.._ -_._.________ __._.-_._._._._. Replacement (yes or no)

A . 0 Repaired, [ No 2MCR-NV-4058 Duke Power N/A N/A Hanger N/A 0 Replaced,

__3 . .  : - -  : . Replacement 0 Yes B 0. Repaired, 0 No 0 Replaced,.

___..... . . . .0 Replacement 0 Yes C . . . 0 Repaired, 0 No 0 Replaced,.

.5- .. . *.. OReplacement 3 Yes -

D 0 Repaired, 0 No.

0. Replaced,.

.__ _ .- . . . - . . . - .  ; -:  ; _0 Replacement 0 Yes E. 0 Repaired, 0 No

.. . OReplaced,

__  :. -- . . 0 Replacement 0 Yes F . . . 0. Repaired, 0 No..

0- Replaced,

._ .. ._ ._ ..  :. 0 Replacement 0Yes Page 1 of 2 Revision 7

  • ~~ I Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced item # 2
8. Test Conducted:Hydrostatic EJ Pneumatic 0 Nom. Operating Press. 0 Other 0 Exempti ,

Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF

9. Remarks (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl' Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Slgned F.R. Sorrow. QA Tech Support Date 04/08, 2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION .

1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period 3Z ?1 Sto 4/9/0os : and state that to the best of my knowledge and belief, the Owner has performed e iamnations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for.

Any personal inJu r property damage or a loss of any kind arising from or connected with this

//spectio. /.

A/rome F Swan Comnmissions -NC1524, N-1 inspecto s ure National Board, State, Province and Endorsements 6 Date i

Page 2 of 2 Revision 7

FORM NIS-2 OWNER'S RL. RT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl C

1. Owner Address: Duke Power Comoanv 1a. Date 03/2912005 526 S. Church Street. Charlotte. NC 28201-1006 Sheet 1 of I
2. Plant Address: McGuire Nuclear Station 12700 Haders Ferry Road. Huntersville. NC 28078 2a. Unit: 01 l12 033 OShared (specify Units
3. Work Performed By Duke Power Comoanv 3a. Work Order # : 98620710/18 Address: 526 S. Church Street. Charlotte NC 28201-1006 Repair Organization Job #

Type Code Symbol Stamp: N/A Authorization No. NŽA Expiration Date: S/ 3b. NSM or MM #: N/A

4. (a) Identification of System: RN - 4. (b) Class of System: B
5. (a) Applicable Construction Code: ASMEIII 1971 Edition, Summer and Winter Addenda,' N/A Code Cases (b) ,Applicable Edition of Section Xl Utilized for Repalrs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Components RePaired or Replaced and Replacement Coi onents:

Column 1 Column 2 . Column 3' Column 4 Column 5- Col 6 Column 7 Column 8 Name of Component - . Name of Mfg Mtg Seral No. National Board No. Other Idenification Year Built Repaired, Replaced, or ASME Code Stamped

____ ____ :_____ .__.. ___ Replacement (yes or no)

A . 0 Repaired, 0 No RN Piping - Duke Power N/A 60 N/A 1982 3 Replaced,

.- . iReplacement [IXYes B . 0 Repaired, - O No O Replaced,

..-:' _... O Replacement ElYes C .3 Repaired, 0 No E. Replaced, -

.__ __ . . -_._. _ ._ . o Replacement El Yes D 0 Repaired, 0 No

.. Replaced,

.. _..__.-.__I .. O Replacement 0 Yes E .. Repaired,. 0 No

.. Replaced,

.__ ..  :. . . _ .. . . . O Replacement ElYes F - ORepaired, O No

.. Replaced,

._ ._ ._ :_- _. . Replacement El Yes Page 1 of 2 Revision 7

. I Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) -

size is 8 1/2 in.x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Perform weld overlay on welds RN2FW57-1 and RN2F-1515
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 0 Exempt[F]

Pressure psig Test Temp. OF Pressure ____psig Test Temp. OF Pressure psig Test.Temp. OF

9. Remarks (Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed F.R. Sorrow. QA Tech SupDort Date 03/29, 2005 Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina' and employed by l SBCT have insp ted he components described in this Owner's Report during the period

/ZZ/ to  % and state that to the best of my knowledge and belief, the Owner has performed exarfinaflons and taken corrective measures described in this Owner's Report In accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury r property damage or a loss of any kind arising from or connected with this nspection./

rome F Swan Commissions NC1524, N-I Inspector'sp 7 National Board, State, Province and Endorsements I I

)Date se / I I I

Page 2of 2 Revision 7

FORM NIS-2 OWNER'S ijRT FOR REPAIRS OR REPLACEMENTS C As Required By The Provisions Of The ASME Code Section Xi

1. Owner Address: Duke Power Comoanv 1- 1a. Date 03/30/2005 Mcj o.

ul %Nucla Stato

.. Kr' hnO3n003fl4AM V

Sheet 1 of 1

2. Plant Address:- McGuire Nuclear Statlon 12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 i]2. 03 i3Shared (specify Units )
3. Work Performed By. Duke Power Companv 3a. Work Order # :98620711/16 Address: 526 S. Church Street. Charlotte NC 28201-1006 - Repair Organrhation Job I Type Code Symbol Stamp: NA Authorizatlon No. NA Expiration Date: NIA 3b. NSM or MM # N/A  :
4. (a) Identification of System: RV 4. (b) Class of System: B& C
5. (a) Applicable Construction Code: ASME II 1971 Edition, Summer and Winter Addenda, N/A Code Cases' (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Components Repaired or Replaced and Replacement Com zonents: -

Column 1 Column 2 . Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg M Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

___ _ __ ___ __ ___ __ __ __ __ ___ __ __Replacem ent (yes or no)

A :E Repaired, 0 No RV Piping Duke Power N/A 72 N/A; 1982 0 Replaced,-

. . . .- , -., * . *. OReplacement iWaYes B . . 0 Repaired, 0 No O. Replaced,-

____ ______ . Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,:

_.__'_'_. .. 0 Replacement 0Yes D 0 Repaired, O No 0 Replaced,

____3 . .Replacement O Yes E 0 Repaired, 0 No 0 Replaced.

_ _ . 0 Replacement 0 Yes F 3.Repaired,. 0 No.

. .0 Replaced,

_ ,_ -_ ... ._ ._ -0 _ Replacement O Yes Page 1 of 2 Revision 7

mu Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Perform weld build up on welds RV2FW40-7 and RV2FW21-36
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 0 Exempti[M Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure . psig Test Temp. OF
9. Remarks (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed G F.R. Sorrow. GA Tech Suonort Date 03/30, 2005 Owner or Owner's Designee, Title

[i.

I . I ."  ;  :

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have insp cteri the components described in this Owners Report during the period 3i2i7c to 3/ 34.05 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners,.

Report. Furthermore, neither the Inspector nor his employer shall be liable Inany manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

ome F Swan Commissions NC1524. N-I

/re Natlonal Board, State, Province and Endorsements Page 2 of 2 Revision 7

( r I FORM NIS-2 OWNER'S Ri-.oRT FOR REPAIRS OR REPLACEMENTS As Reaulred By The Provisions Of The ASME Code Section Xi

.1. Owner Address: Duke Power Comoanv 1a. Date 04106/2005  :

- - I.- M-ut lr (Ih In^h %trfrnMt ehar c...a St ato. - .u ttg%:Nr

%nJa Paq1n.i

  • -n vvv A! 4 Sheet 1 of 1
2. Plant Address: McGuire Nucleatr Statlon - -

12700 Haaers Ferr, Road. Huntersville, NC 28078 2a. Unit: 31 02 03 OShared (specify Units )

3. Work Performed By. Duke Power Comwanv 3a. Work Order #
  • 98620713/11 Address: 526 S. Church Street. Charlotte NC 28201-1006 Repair OtganIraflon Job * '-

Type Code Symbol Stamp: M1LAuthorization No. N/A Expiration Date: N/A 3b. NSM or MM #: N/A

4. (a) Identification of System:. RV . -. 4. (b) Class of System: B
5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Components Repaired or Replaced and Replacement Corn onents: - -

Column 1 Column 2 - Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Othe Identificaton Year Buift Repaired, Replaced, or ASME Code Stamped

__ _ _ _ __ _ __ _ __ __ _ _ _ _ __ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _R eplacem ent (Yes o r no)

A  :; Repaired, 0 No RV Piping DukePower N/A 72 N/A' 1982 0 Replaced,

- OReplacement EMYes B 03Repaired, 0 No

-O Replaced, 0 Replacement 0 Yes C 0 Repaired, 0 No 03Replaced, -

_3 - - 0Replacement 0 Yes D 0 Repaired, 0 No.

0 Replaced,

.____3 , - _  ; 0Replacement 0Yes E 0 Repaired, 0 No O3 Replaced,

':3 _ - O Replacement 0Yes-F , 0 Repaired, 0 No 0 Replaced,

-_3 - ,. _  : - -:-0 Replacement 0Yes Page I of 2 Revision 7

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Perform weld build up on weld RV2FW21-30
8. Test Conducted:Hydrostatic El Pneumatic 0 Nom. Operating Press. 0 Other 0 ExemptE1 Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks (Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Sig ne4/ v F.R. Sorrow. QA Tech Sunport Date 04/06, 2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HAB C have Insp ctod the components described In this Owners Report during the period to;.. Z4ZcKa to and state that to the best of my knowledge and belief, the Owner fias performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In the Owner's -

Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this finspection. 1 .... /

oeF Swan Commissions NC1524.N-1l r/ inspector'spifipre National Board, State, Province and Endorsements I ---

Page2of2 Revision 7
  • i FORM NIS-2 OWNER'S Ri:(RT FOR REPAIRS OR REPLACEMENTS C As Required By The Provisions Of The ASME Code Section Xi
1. Owner Address: Duke Power Comoanv 1a. Date 04/06/2005 526 S. Church Street. Charlotte, NC 28201-1006 Sheet 1 of I

-I

2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 iK12 03 OShared (specify Units ;_)
3. Work Performed By. Duke Power Comoanv 3a. Work Order # : 98620713/15 Address: 526 S. Church Street. Charlotte NC 28201-1006 Repair Organztion Job #

Type Code Symbol Stamp: B Authorization No. WA Expiratlon Date: NA 3b. NSM or MM #: N/A

4. (a) Identification of System: RV 4. (b) Class of System: B'
5. (a) Applicable Construction Code:-ASME ili 1971Edition, Summer and Winter Addenda, N1A  ; -Code Cases.;

(b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identication ot Compon rnts Repaired or Replaced ana Replacement Com onents: _

Column 1 Column 2 - Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Componer Name o Mfg Mfg Serial No. Naftional Board No. - Oter Identification Year Bult Repaired, Replaced, or ASME Code Stamped

. __ .__ .__ ._ ._ ._ -. Replacement (es or no)

A - EI Repaired, 0 No RV Piping Duke Power N/A 72 N/A 1982 0 Replaced,

_ .

  • OReplacement lKIYes B . 0 Repaired,. 0 No
-  ; ;
O Replaced,;-

0 Replacement 0 Yes C - - 0 Repaired, 0 No 03Replaced,'

3 ._ _ 0Replacement 0Yes" D 0 Repaired,: 0 No
' .  ; OReplaced,
_3 ' .  ; . .
0 Replacement 0 Yes E 0 Repaired, 0 No 03Replaced,

-- ' 0 Replacement 03Yes F .3  ; ORepaired, .O No 03Replaced,

. . O0 Replacement 0 Yes Page 1 of 2 I

Revision 7

aI Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Perform weld build up on weld RV2FW20-20
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 0 ExempitEl Pressure pSig Test Temp. OF Pressure psig Test Temp. °F Pressure psig Test Temp. .. OF
9. Remarks (Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed - v F.R. Sorrow. QA Tech Support Date 04/06, 2005 owner or Owner's Designee, Ttle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by USnCT have the components described in this Owner's Report during the period 3 O4;/m to  ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employereshall be liable in any manner for any personal injuryi r property damage or a loss of any kind arising from or connected with this

/nspection. b e F Swan Commissions NC1524, N-I Inspector's grure National Board, State, Province and Endorsements Date Page 2 of 2 Revision 7

(1

  • FORM NIS-2 OWNER'S Rl- ,AT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XA

( .

1. Owner Address: Duke Power ComDanv - 1 a. Date 03/30/2005

. COA Q tlheomh -Qfroof elharlAffii mr owmi.innn, Sheet 1 of 1 I

2. Plant Address: McGuire Nuclear Station -

12700 Hagers Ferrv Road. Huntersville. NC 28078 2a. Unit: 01 0312 03 0Shared (specify Units )

3. Work Performed By, Duke Power Companv 3a. Work Order #: 98620714:20 Address: 526 S. Church Street. Charlotte NC 28201 -1006 Repair Organization Job #

Type Code Symbol Stamp: N/A Authorization No. W Expiration Date: N/A 3b. NSM or MM #: N/A

4. (a) Identification of System: RN - 4. (b) Class of System: B
5. (a) Applicable Construction Code: ASME 1ll 1971 Eddilon, Summer and Winter Addenda, NWA Code Cases (b) Applicable Edition of Section Xl Utilized for.Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Components Repaired or Replaced and Replacement Corn onents: .

Column 1 . Column 2 ,Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg - Mfg Serial No. Natlonal Board No. Oterw Identification Year Bult Repaired, Replaced, or ASME Code Stamped

.___._ , __ _ __ __ _ _ . . . .. .Replacement (yes or no)

A  :. IiRepalred, 0 No, RN Piping Duke Power.. N/A 60 N/A 1982 0 Replaced,,

._3 .  : . . .. . . .0 Replacement 0iYes B 0 Repaired,. 0 No

. 0.Replaced, 0.Replacement 0 Yes C 0 Repaired, - 0 No 03Replaced,.

.  : . . .. ._.._ . 0 Replacement 0Yes D . . 0 Repaired,- 0 No 03Replaced, 0 0 Replacement _3 Yes E .- 0 Repaired, 0 No 0.Replaced,

-._O0

.- Replacement 0Yes F .3. .. 0 Repaired, 0 No 0 Replaced,

_ . . . ... 0 Replacement 0 Yes Page 1 of 2 Revision 7

. I Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Perform weld buildup at weld RN2F-1489
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 0 ExemptEO Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. .OF
9. Remarks (Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed1 JL dAe.4/ F.R. Sorrow. QA Tech SUDDOrt Date 03/30 2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of -North Carolina and employed by HSB CT. have Inspcted he components described in this Owner's Report during the period to and state that to the best of my knowledge and belief, the Owner has performed e naminatlons and taken corrective measures described in this Owners Report In accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury r property damage or a loss of any kind arising from or connected with this l1Inspection. >

me F Swan Commissions NC1524. N-I Inspecto sre National Board, State, Province and Endorsements lDat 0ot~

Page 2 of 2 Revisioa 7

(C FORM NIS-2 OWNER'S RtjRT FOR REPAIRS OR REPLACEMENTS As Requlred By The Provisions Of The ASME Code Section Xi C.,

1. Owner Address: Duke Power Companv la. Date 03/24/2005 526 S. Church Street. Charlotte. NC 28201-1006 ' Sheet of
2. Plant Address: McGuire Nuclear Station  : A4 ..

12700 Hasers Ferr, Road. Hunfersvllle. NC 28078 2a. Unit: 01 02 03 OShared(specify Units -

3. Work Performed By: Duke Power Comoanv 3a. Work Order #: 98629559/01 Address: 526 S. Church Street. Charlotte NO 28201-1006 Repir Organiaon Job #

Type Code Symbol -Stamp, N/A Authorization No. NIA Expiration Date: NWA 3b. NSM or MM #: N/A

4. (a) Identification of System:' SV 4. ' (b) Class of System: B
5. (a) Applicable Constnuction Code: ASME III 1971 Edition,' Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Compon nts Repaired or Replaced and Replacement Coin onents:

= Column 1 - Column 2 - Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name od Component Narne ot Mfg, Mfg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

. _ . . Replacement (yes or no)

A 03Repaired, 0 No Valve 2SV-19 B&W' '  : 15958-5-4 14 N/A 1977 0 Replaced,'

- 0 0 Replacement 0 Yes B 0 Repaired, 0 No 0 Replaced,'

, - - 0 Replacement 0 Yes C - 0 Repaired,. 0 No 0 Replaced,

-3 - ' O Replacement 0Yes D 0 Repaired,. 0 No 03Replaced, .

'3 ; _ _ 0 Replacement 0 Yes E O Repaired, O No

' . . y . ' ' Replaced,

__ '_ :_ -- _ _ 0 Replacement 0 Yes F 0 Repaired, 0 No

. 0 Replaced,

. 0Replacement 0Yes Page I of 2 Revision 7

. I Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced plug and stem assembly
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 0 Exempt[J Pressure psig Test Temp. _F Pressure psig Test Temp. OF Pressure pSig Test Temp. OF
9. Remarks (Applicable Manufactureis Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed F.R. Sorrow. OA Tech SupDort Date 03/24, 2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HS CT have ins ted e components described in this Owners Report during the period tto /a n d state that to the best of my knowledge and belief, the Owner has p rformed examin tlons and taken corrective measures described in this Owner's Report In accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injuryr property damage or a loss of any kind arising from or connected with this lInspection.>n mea F Swan Commissions NC1524 N-I pectoNational Board, State, Province and Endorsements Page 2 of 2 Revision 7

.I (3

i-FORM NIS-2 OWNER'S RLJRT FOR REPAIRS OR REPLACEMENTS As Required By The Provislons Of The ASME Code Section Xi

(_

1. Owner Address: Duke Power Comoanv la., Date 03121/2005 526 S. Church Street. Charlotte. NC 28201-1006 Sheet _ of
2. Plant Address: Mc~uire Nuclear Statlon

- 4 12700 Haaers Ferry Road. Huntersvitle. NC 28078 1 :1'.

2a. Unit: 01 0S2 i3 OShared (specify Units

3. Work Performed By. Duke Power Comoanv 3a. Work Order # : 98629559/07 Address: 526 S. Church Street. Charlotte NC 28201-1006 - Repair Orgazaton Job t Type Code Symbol Stamp: N/A Authorization No. NQ Expiration Date: N/A 3b. NSM or MM #: N/A
4. (a) Identification of System: SV 4. (b) Class of System: B
5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Componrints Repaired or Replaced and Replacement Coin onents:-

Column 1 Column 2 Column 3 Column 4 Column 5 -Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Ote Identification Year Built Repaired, Replaced, or ASME Code Stamped

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _R eplacem ent ( me or no)

A v - .El N/ Repaired, O No -

Valve 2SV-19 -B&W 514 N/A 1977 0 Replaced,

- 0 Replacement El Yes B 0 Repaired, 0 No 0 Replaced;

. 0 Replacement 0 Yes C 0 Repaired,- 0 No

. .0 Replaced,

- °Replacement O Yes D ORepaired, ONo 03Replaced,

__: [3. Replacement O 0 Yes E  ; 0 Repaired, 0 No 0-Replaced,

' 0 Replacement 0 Yes F 0l Repaired O No 0 Replaced,

__ __ . __ O__0 Replacement 0Yes Page I of 2 Revision 7

xi Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Perform weld build up on body at bonnet seat area.
8. Test Conducted:Hydrostatic 0 Pneumatic iJ Nom. Operating Press. 0 Other 0 ExemptEl Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks (Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A (i-I Certificate of Authorization No. N/A Expiration Date N/A Signed e c F.R. Sorrow. QA Tech SuDDort Date 03121, 2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by 483 CT have insp the components described in this Owners Report during the period to XA DS ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report Furthermory, neither the Inspector nor his employer shall be liable in any manner for y personal injur property damage or a loss of any kind arising from or connected with this spection.G ome F Swan Commissions -NC1524, N-nsp National Board, State, Province and Endorsements Date3/;/2 Page 2 of 2 Revision 7

  • > ... i' 4! --

C, FORM NIS-2 OWNER'S REPC L 1FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xi C

1. Owner Address: Duke Power Comranv Ia. Date Avril 12. 2005 1 S9A Chuirch Stret. Charintt.n NC 28201 -1006 Sheet 1 of 1
2. Plant Address: -McGuire Nuclear Station -

12700 Haaers Ferrv Road. Huntersville, NC 28078 2a. Unit: 031 02 03 0Shared (specify Units ;_)

3. Work Performed By: Duke Power Companvy 3a. Work Order #: 98645487 Address: 526 S. Church Street. Charlotte NC 28201-1006 Repair Orgalzatton Job #

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: NA' 3b. NSM or MM #:* N/A

4. (a) Identification of System: - BB - Steam Gen6rator Blowdown Recycle 4. (b) Class of System: B
5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases. -

(b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity: 1998. 2000 Addenda, (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components:  : .-

= Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Componet - Name of Mfg Mfg Serlal No. National Board No. Oter Identificaton Year Built Corrected, Removed, or ASME Code Stamped

__ . _ ,, _ _ _ .,_ :. . .,.., _ _ .-_ _ __ , ,Instaled (ves or no)

A - . .. 0 Repaired, O No 2-BB-VA-2 Borg - Warner 9088 104 N/A - 1976 . Replaced,:.

.__ .__ ._ ._ .. ... . 0 Replacement El Yes B 0 Repaired, 0 No 2-BB-VA-2 BW IP - E496P-1-2 . 2224 N/A 1999 0 Replaced, l Replacement El Yes-C . 0 Repaired, 0 No 0 Replaced;

.. ____ . .. - .- ; O Replacement DYes D 0 Repaired, 0 No 03Replaced,

.___ .__ -__ .. -. . . 0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,

.. _ - _ ._ . . . ... . 0 Replacement O Yes 03Repaired, 0 No 0 Replaced,,

._ ._ ._ . ... 0 Replacement 0 Yes Page 1 of 2

. I Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced 2-BB-VA-2
8. Tests Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. El Other 0 Exempto Pressure 1090 psig Test Temp. 422 OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks Test performed per MPI0/A/7650/076 (Applicable Manufacturers Data Reports to be attached)

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass Jr.QA Tech Specialist Date /

IOwner 9eOwner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I; the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HS CT have ins the components described in this Owner's Report during the period

!3 I/ Alfkto .6*//0L;; and state that to the best of my knowledge and belief, the Owner h~sperformed eKaminations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owner's ReporL Furthermore, neither the Inspector nor his employer shall be liable in any manner for

,any personal inJu or property damage or a loss of any kind arising from or connected with this

/ins~pection. A

-A - rome F Swan Commissions NC1524, N-1 nsp National Board, State, Province and Endorsements Date a

Page 2 of 2

FORM NPV-1 MANUFACTURERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES As Required by the Piovistons of the ASE Code Rules

.... Flowserve Corp.

1. Manufactured bL 701 First Street, Iilliamsport, PA' 17701 Orde r-No E496P-1 (Nm.* Addreso e nutet) 'a'u'a't'

-- Duke Energy Corporation, P.O. Box 1015, Charlotte, NC. -. MN ...49678

2. -Manufactuted foe Orde r N (ffiae a"4 "dress) ZBZOl-1015.

r%

. A .. I . . .

3. Duke U cneryy ourpuraiun - -

McGuire Nuclear Station, 13225 Hagers Ferry-Rd., Huntersville, NC.

4. Location of Plan28078-8985.

--p -le -- Valve,- Two

5. Pump or Valve Identifucationb (2),-2"-1500#- .GateYValYe. -

Serial Numbers: E496P-I-1 and E496P-1-2 -- - -- '

(Brief description of clerlce for which equipment was designed) 74450 R/C V1~Jwnr¶7v Cornr---

(a) Drawing No. - - Prepared by_--

NB# 2223, NB# 2224 (b) National Board No.

6. Design Condidons 3600 p; -- 100 (Temperature)

OF 2

7. The material, desin, construction, and workmanship complies with ASME Code Section HI. Class

-Edition 1971 ,

,Addenda Date (S) 1973 193*Case No. __

N/ _ ___NoN/A

. I - I s pee. no. I msuacturt Iemara. II.~

4

.,(a) Castings _____________________ 4 4 UfIC T. Pc#? SA'951_CF8M CMI -

.. . .. T~i .---

... -. _... _ -- -.. . .. .1 -

-nIIU LI7aj -

(b) Forg inga. - -- - _

Body; SN tl, SN 12 SA182F316 BW/IP PumP Div.

RS# 303856; T/C: A5 .

Bonnet: PC# 1. PC# 2 SA182-F316 Mid-Southern HT# L49056 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

FIOK NPV-1 (back)

Merk Ito. Materitt Spee. t. maauacttrer Remark WC)Boltin6 I I ---

_N/A lI -.

I A

.4

- 4 4 (d) Other Prts N/A _

I .

.4 I

.4 d5400

8. Hyrostatic test~~ psi CERTIFICATION OF DESIGN Designinhlormaiononfie at Flowserve Corporation, Williamsport, PA. 17701 Stress analysis report on file at Same as above Design pecifieuions certified by R. E. Miller (1) Prof. Eng.State SC Reg.No 4237 Stress analysis report certified by N/A (l)Prof. .Eng.St ce - Reg. No.-

(I) Signatwre not required. List name only.

We certify that the statements made in this report are correct.

Date __ k.9

___2_d 19.. Sianed V

Flowserve Coro.

- (Mamdaur Byr

-DO&L Ceitificate of Azthorizarion No. N1712 expires 4/15/01 CERTIFICATE OF SHOP INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and/or the State ofmtra of - and employed b emmhrre 4al Mt4nr Tin t-n o Rnaon1n Ma _ have Inspected the equipment described in this Data Report on00 o i9. and stare that to the best of my knowledge and belief, the Manufacturer has constructed this eqiptent in accord e with the applicable Subsections of ASME Code, Section tI.

signing this certificate, neither the Inspector not his employer makes any warranty, expressed ot implied concern-ing a equipment described in this Datn Report. Furthermore neither the Inspector nor his employer shall be liable in any nner for any personal injury or property damage or a loss of any kind drising from or connected with this inspection.

Date 8 1199 2Z c7rioug K'1%er___05_ - tozmsuaauz Pennsvlvania 2192 M45sv (N~ational 1100fd9 State. Province and No.)

W 11 Prited to U.S.A. C7/71) Thil form (KS7) Is obtainablt from the ASMZ, 34S 1. 47th St.. New York. N.Y. 10017

C FORM NIS-2 OWNER'S RCi IhT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI Eii"

1. Owner Address: Duke Power Companv la. Date 04/07/2005

. - _526 S. Church Street. Charlotte. NC 28201-1006 - Sheet 1 of 1;

2. Plant Address: McGuire Nuclear StAtiori -

12700 Haners Ferry Road. Huntersvllle. NC 28078 2a. Unit: 01 02' 03 0Shired (specify Units_)

3. Work Performed By: Duke Power Companv 3a. Work Order #: 98645487-11 Address: 526 S. Church Street, Charlotte NC 28201-1006 Repair Organization Job
  • Type Code Symbol Stamp: MIA Authorization No. MA Expiration Date: N/A 3b. NSM or MM #: ME200303
4. (a) Identification of System: BB 4. (b) Class of System: B
5. (a) Applicable Construction Code: ASME 1111 971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identifcation of Compon nts Repaired or Replaced and Replacement Comionents:
  • Column 1 Column 2- - Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Compone Name of Mfg Mfg Serial No. National Board No. Oter Identificaton Year Built Repaired, Replaced, or ASME Code Stamped

_. Replacement (yes or no)

A 0 Repaired, 1H1No 2MCA-BB-5489 Duke Power N/A N/A Hanger N/A 0 Replaced,

._ _ _ _ _ _ _ _ Replacemrient 0 Yes B 0 Repaired,- 0 No 0 Replaced,

.. .. . . . .0 Replacement 0 Yes c 0.Repaired,; 0 No -

03Replaced,-

._3 .  : , . Replacement 0 Yes' D 0 Repaired, 0 No.

0 Replaced,.

-___. __ .. . _:': . . 0Replacement 0Yes E 0 Repaired, 0 No 0 Replaced,

. . . _3 . . Replacement 0 Yes F 0 Repaired, 0 No -.

0 Replaced,.

._ - . . .0 Replacement 0Yes Page 1 of 2 Revision 7

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced item 4 and added item 12
8. Test Conducted:Hydrostatic U Pneumatic E Nom. Operating Press. 0 Other 0 Exempto Pressure psig Test Temp. -F Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks (Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signec F.R. Sorrow. QA Tech SUpDOrt Date 04/07, 2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hs C have inspete the components described in this Owner's Report during the period to . and state that to the best of my knowledge and belief, the Owner hasiperformed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concernin the examinations and corrective measures described In the Owner's eport. Furthermo, neither the Inspector nor his employer shall be liable in any manner for ny personal inju r property damage or a loss of any kind arising from or connected with this

{/nspection.}

rome F Swan -sCommissions N N-I Inspecr e National Board, State, Province and Endorsements Page 2 of 2 Revision 7

FORM NIS-2 OWNER'S RiL-RT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl Cf'

1. Owner Address: Duke Power Comrranv I a. Date 03124/2005

-526 S. Church Street. Charlotte. NC 28201-1006 - Sheet 1 of 1

2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville, NC 28078 2a. Unit: O1 02 03 iiShared (specify Units )
3. Work Performed By. Duko Power Company '3a. Work Order #: 98647610101 Address: 526 S. Church Street. Charlotte NC 28201-1006 RepaIr Organtzat lJob t

Type Code Symbol Stamp: N1A Authorization No. W6 Expiration Date: WA 3b. NSM or MM #. NIA

4. (a) Identification of Systenm: NV 4. (b) Class of System: B
5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A' CodeCases (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports) ff. Identification or Compon ents Repaired or Replaced and Replacement Uom 3onents: ;___ - _

Column 1 Column 2 Column 3 Column 4 Column 5- Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other identification Year Built Repaired, Replaced, or ASME Code Stamped

._ _ ... Replacement (yes or no) I' A .O Repaired, - ONo . I : .. 4 NV Piping System Duke Power N/A .. 80 N/A. 1982 O Replaced,

. - ._____._.._. 0 Replacement 0Yes B . 03 Repaired, 0 No 03Replaced, E3 Replacement 0 Yes C .0 Repaired,- 0 No 0 Replaced,-

_ _ .:0 Replacement 0Yes D . 03 Repaired,, 0 No.

0.Replaced,  :

_ ____... .3_ 0Replacement 0 Yes E ORepaired,, O No 3OReplaced,

.___3 0Replacement 0 Yes F 0;Repaired, 0 No' 03Replaced,

__3 . . . . . .0

_._.. Replacement 0 Yes Page 1 of 2 Revision 7

. I Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced studs and nuts at 2NVFE-5530 flange connection
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 0 ExemptIM Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. _ OF
9. Remarks (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed e F.R. Sorrow. QA Tech Support Date 03124 2005 Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HS CT ave insppctedthe components described in this Owner's Report during the period 3/ Z to - -to and state that to the best of my knowledge and belief, the Owner Its p rformed 6xamlnations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for kny personal injury oh property damage or a loss of any kind arising from or connected with this ftspection- /

ome F Swan Commissions NC1524. N-I inspector's National Board, State, Province and Endorsements J Dat.3 Y/

Page 2 of 2 Revision 7

C- (9\ f '.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provislons Of The ASME Code Section Xl

1. Owner Address: Duke Power Comroanv ia. Date Februarv26.2004 i.. i 526 S. Church Street. Charlotte. NC 28201-1006. Sheet 1 - of 1-
2. Plant Address: McGuire Nuclear Station 12700 Habers Ferry Road. Huntersvlile. NC 28078 2a. Unit: 01 02 03 OShared (specify Units I
3. Work Performed By Duke Power Comoranyv 3a. Work Order #: 98650088 Address: 526 S. Church Street, Charlotte NC 28201-1006 ,' - - . Repair Orgarization Job #

Type Code Symbol Stamp: N Authorization No. NIA Expiration Date: 1 -3b. NSMorMM#: N/A

4. (a) Identification of System: KC - Comoonent Coollna 4. (b) Class of System: B
5. (a) Applicable Constructlon Code: ASME liI 19Zj Edition, Summer and Wlnter Addenda, N/A -  ! Code Cases -

(b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1989. No Addenda (1992 through 1992 Addenda for Class MC and CC and their supports) i I .

.. I- .. . -1 . .. - . . - . . ... .- I.:  %, .

6. identification ot Components Repaired or Replaced and Replacement Com onents: -

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mifg Mfg Serial No. National Board No. Odwer Idertfication Year Built Repaired, Replaced, or ASME Code Stamped

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _R epla c em e nt es o no A 0 Repaired, 0.No 2KC-VA-479 Kerotest DA7-25 6182. N/A 1975 0 Replaced, -

.____E ._._. ._._.._ . l Replacement l Yes B -3. 0 Repaired, 0 No O Replaced,

._3 . . . - . .O Replacement 0 Yes C .. 0 Repaired, 03No 03Replaced,

._3 . . ._._._. .O Replacement .Yes D 03Repaired, 0 No

. 0 Replaced,

. ._ _ . __ . . .O 0 Replacement 0 Yes E 03Repaired, 0 No 03Replaced,

.__3 -.. . . . . . .0 Replacement 0 Yes, F .- .* .Repaired, O No -

0 Replaced,

.. 0 Replacement 0Yes Page I of 2 Revision 7

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced disc and bonnet
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. El Other a ExemptOl Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure _psig Test Temp. OF
9. Remarks (Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made iq the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass Jr.. QA Tech Soecialist M _ . ., .

Date 2 6/OsY Owner,6r Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTiON 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period q- toa2 6^Dy : and state that to the bestof my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.,

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspec n.

A R.D. Klein Commissions NC853. N-I insvcisb ue National Board, State. Province and Endorsements Date i a Y Page 2 of 2 Revision 7

I i

C. FORM NIS-2 OWNER'S REPL" FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xl

( I

1. Owner Address: Duke Power Comnany Ia. Date Airii 10. 2005 526 S. Church Street. Charlotte. NC 28201-1006 Sheet 1 of 1
2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville. NC 28078 2a. Unit: 01 02 03 0Shared (specify Units )
3. Work Performed By, Duke Power Companv 3a. Work Order #: 98652410 Address: 526 S. Church Street. Charlotte NC 28201-1006 Repar Orson Job -

Type Code Symbol Stamp: N/A Authorization No. NA Expiration Date: NA 3b. NSM or MM # N/A

4. (a) Identification of System: - NC - Reactor Coolant 4. (b) Class of System: A
5. (a) Appilcable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, NWA Code Cases (b) Applicable Edition of Section Xl Utilized for Repair Replacement Activity, 1995. 1996 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Components:

Column 1 Column 2 Column 3 Column 4 Column 5 . Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other dnificabon Year Built Correted, Removed, or ASME Code Stamped Installed (yes or no)

A  :. Repaired, 0 No 2-NC-VA-3 Crosby

.. - N56925-00-0001 25 ' N/A 1974 El Replaced,

._ ._ ._ .  : . . . ... 0 Replacement E Yes B 0 Repaired, 0 No 2-NC-VA-3 Crosby N56925-00-0002 26 N/A 1974 3 Replaced,

__El _ -I_._._ _. Replacement E Yes C 0 Repaired,. 0 No 0 Replaced,

. _____ ' . . . ;' . . , . . . . - .. Replacement 0 Yes D3.- . . . . 0 Repaired, 0 No

. .--. .' ' - . . .. . . ....... .:..3Replaced,.

__ ._. _. _. _. _ . _. _. _. ._ . _:. __. _ R eplacement 0 Y es' E . . 0 Repaired, 0 No 0 Replaced,.

...-. -. .. OReplacement 0Yes F . - 0 Repaired,. 0 No 0 Replaced, .

,_ ._ . . . . . .- . . .: . 0 Replacement 0 Yes Page 1 of 2

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Replaced valve
8. Tests Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 0 ExemptO Pressure 2235 psig Test Temp. 537 OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks Test performed per w/o# 98652978/01 (Applicable Manufacturer's Data Reports to be attached)

CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass Jr.OA Tech Specialist Date -

Owner ortwner's Designee, The CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HS8 CT have inspeptedkthe components described in this Owner's Report during the period to Y R S: and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report In accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for ny personal injury property damage or a loss of any kind arising from or connected with this

/ spection.

ome F Swan Commissions N Inspectors Si National Board, State, Province and Endorsements 6 Date Page 2 of 2

4 J

C 0 3 Y V A LV E t  %>

W R E N TW1H A M, M A S5 7-

  • -..-- y *.; 70FR sAVETrY AND SAF-ETy RELIEP VALVES Q.C.-44B 1;. At tCquxted by theC ptovIsions ol the ASSME Code Rules NB-26 DATA REPORT Safety and Safety Relief Valves REVISED 10/23/74 a

t ~ve & Gage Cornoenv. 43 1endrick St. . Wren tham, ,Mass. 02093 fl o~ 't'J-BP-86 . a~me and Address

';5925 Order N~o. N-300580 Conttact Date 2/12/73 F'. Duke Power Company . ..

F-ro Charlotte, North Carolina Order N'o. A-33957 I

Name and Address..

t ' tike Poser Co.. 422 South Church St., Charlotte. North Carolina 28201 I

I Name and Address 7 L ra:for plant NcGuire Nuclear Station Unit Irl, Cowans Ford, North Carolina 4 rVIIYe Identification 1-NC-2 Serial No. _1456925-00-0002 Drawing :o. nS C56925 -Rev. O 2.154 Tre Saf ety *. Orifice Size..iL...... Pipe Size ____Inlet- 6...j.outiet 6 I; .

safety.Safety Relicf.Pllot.Powec Actuated Inch Inch Pte  : Ineh C. Set Pgessure (PSI) 2485# 7000 Rated Tenpetatu:e Stip~d Capacity, 420006/hrt. a 3. -, overpressure 3 Blnwdown #PSCG _124 Stna . .1.2.

lydtotatic Test (PSIOJ Inlet_ 4575 Complete Valve 750

1. The matetiaI. design, construction and wo:kmanship comply with ASME Codc..Section i11.

Class Edition. 1971 Addenda Date Winter 1972 Pressure Containing or Pressure Retaining Components Serial Nd.

  • Material Specification
a. Castings
  • Jdentitication .
  • Includin.- Type oa Cr.sde ABSTM A:351-o72 Cr. UCF Body H 20.72-31 -

0AlZ.....S ~ ~ & 3 51 Cr. CrSM ASII iY 15-71 Gr. II Bonnet . 93 5 .. E S3A.Qfl tS-A15 71 I

b. Ear Stock and Forgings Sup Ort Rods *_*

-Nozzle .ozeN90399-34-0008 .~@lG; &i1/2L r G

  • Disc Insert lo. 0 116-3l-fl01 A vdli 0 te 'R!o. 61B Spnrng Washers Bottatn N903503-32-0)28 AS"ThU SA-105 Gr. J.I

' * ~~A S1'A..:Ih3 :7T f7 -Crib (I Adjus%:n Dolt ai 90351 35-0020 ASM SA1193-Cr. r,6 AS'L1FA-L9 -71. Gr.

  • Spindle 3+/-.1(1rj G 6_ __

ASTI! A-276-72 Type 440 Spindle Ball N90355-0040 ASMIE S;-276 Type 440 V:'

..... z...............................................X U*-f^D7 _

I7 * .. '- *.. 9... *. *JI , .* ,:%., i .

P . .

. .: -... I

  • I,4 , -

i .

-- ' ": ::r : __.. ... Serial No. or Material Specification I e. Boing

-Identlifcation Including Type or Crade

-'-. : .. NX-2761-0014 *- AST -3Cl4 Cr. 51,86O4 _

c.

C.ring,g

. d. Boltier I e. Other Piits such as Pilct Components

-DiscHolder N90356-31-OOOL Tnconel 718 I

&121 -i-71. Gr..B D~nnet-Stud D75S9 AG A r R7 ASTM A-194-7 1 Cr. 211 Bonnet Stud Nut 2371 AV;,NF qA&-1i9 rr~

We certify that the statements made in this report are Correet.

Date /T-~ . - 19.Z L....Sigrnd Crosby Valve & Cae CO. By Man~ufacturer a QA Manager Certificate or Authorization No. 331 expres November 9, 1974

.1 DESIGN INiFORBlAATION ON FILE AT CROS1DY VALVE & GAGE COMPANY.

DESIGN REPORT NO. EC-158.

  • CERTIFICATE Or SHIOP INSPZdTION

..-

  • S..

J. the undecrsigned. holdirn a valid conrvisslon Issued by the National Board of Boiler and PresCure VCssel Inspcctzns ana the State or Pr:ovince of E and employed by.

t1 J<.~r I; 1r.1 C5;1 Y Tztrat~ C .',*- . -!a~~;,1> - - ve inspected the equipment described in this Data Report oil LZ.. 19is/ 2 ard and..

state that to the best of my knowledge and bdlier. the %Iarsuract'uerhas.ccnstru'eted liis equip-r.ent iii accordance with the applicable Subs'ections of ASL4Z Section Ill.

Bly signing this certificate. neither the lnspector nor bus empItiyfr maLes any warranty. ex.

pressed or implied. concerning the eq'uipraerft describee'. itt tt% [inta ecprt.Frur:lerrr.one. r.neier the Inspector cr.orflais erniolover shall be liab'e in any man.act . o: any personal inju:ry or property danmge of a loss (if ny 1an.d atisin, fru:n or canriectcd witl;this iIuspeettoo.

_Xc , _ 'y tory Mutual' Group 6of Insurance Co.

/Connmlss ions h -9 __ z -.

fi !n;pc ;re:r-.r 11at

""~nard. State. Prsovince aiid N~

I

Co FORM NIS-2 OWNER'S RLhT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl C_

1. Owner Address: Duke Power Comoanv la. Date Aorjl8.2005 --

526 S. Church Street. Charlotte. NC 28201-1006 Sheet 1 of I

2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferri Road. Huntersville. NC 28078 2a. Unit: 01 02 03 OShared (specify Units )
3. Work Performed Byi Duke Power Companv 3a. Work Order #:_ 98652770 Address: 526 S. Church Street. Charlotte NC 28201-1006 Repair Organlzatfon Job #

Type Code Symbol Stamp: N Authorization No. N/A Expiration Date: N/A 3b. NSM or MM #-: N/A

4. (a) Identification of System: NC - Reactor Coolant 4. (b) Class of System: B
5. (a) ApplicableConstructionCode: ASME111i19Z.Edition, SummerandWinterAddenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Components Repaired or Replaced and Replacement Coin onents:

_ Column1 Column2 Column3 Column4 Column 5 Co Column7 Column Name of Component Name of Mg - Mfg Serial No. National Board No. Oie Idenflication Year Bult Repalred. Replaced. or ASME Code Stamped

._ I_ ,_.._._._. . Replacement (yes or no)

A 0 Repaired, El No 2-MCR-NC-SG-A Duke Power 4 N/A . N/A N/A 0 Replaced,

.. _ . - . _: . .. E l Replacement 0 Yes B . Repaired, 0 No 0 Replaced,

. ._ .. __ . OReplacement O Yes C . . . 0 Repaired,, 0 No 0 Replaced,

_____ . _ __ OReplacement 0 Yes D 0 Repaired, 0 No 0:Replaced,.

_ __ __ - _._._._. 0 Replacement 0 Yes.

E -. .. . 0 Repaired, 0 No 0 Replaced,

._ . .._ _ _ _ ... _ _ _ OReplacement 0 Yes F .0.. 0 Repaired, 0 No 0 Replaced,

. .  : O0 Replacement 0 Yes --

Page I of 2 Revision 7

.. I Form NIS-2 (Back).

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced control valves in snubber
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other U ExemptEl Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure _psig Test Temp. OF
9. Remarks (Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed k ta Owner or FL Grass Jr.. QA Tech Specialist

~vnet's Designee, Tte Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by iiSB C have inspte the components described in this Owner's Report during the period

/I to tc 4L; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for D

any personal injury or property damage or a loss of any kind arising from or connected with this Inspection UF(ln ..e F Swan Commissions NC1524. N-1 nspecto National Board, State, Province and Endorsements Date ia/f Page 2 of 2 Revision 7

C- FORM NIS-2 OWNER'S REP -. FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section Xi C'

1. Owner Address: Duke Power Companv 1a. Date Aoril 10. 2005 '

I 526 S. Church Street. Charlotte. NC 28201-1006 " Sheet 1 of 1

2. Plant Address: McGuire Nuclear Station 12700 Hagers Ferv Road. Huntersville. NC 28078 2a. Unit: 01 132 -03 0Shared (specify Units )
3. Work Performed By1'Duke Power Comoanv  : - 3a. Work Order#: 98653117 Address: 526 S. Church Street. Charlotte NC 28201-1006 Rrpalr Orghafllon Job #

Type Code Symbol Stamp: N/A Authorization No. W Expiration Date: N/A 3b. NSM or MM #._ NiA

4. (a) Identification of System: NM - Nuclear Samplina 4. (b) Class of System: B
5. (a) Applicable Construction Code: ASME 1111971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repair/ Replacement Activity, 1995. 1996 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Components:

= Column 1 - Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. cmer Identificatlon Year Built Corrected, Removed, or ASME Code Stamped

,_._._- ._._._._,_.._.'_.,* tnstafted (yes or no)

A 03Repaired, 0 No -

2-NM-VA-92 Dresser TH03996 87. N/A 1987. El Replaced,

-  : -3__O Replacement El Yes B 0 Repaired, 0 No 2NM-VA-92 Dresser - TJ17965 . 1952 N/A 1992 0 Replaced,

-__ -____El

_ Replacement El Yes C 0 Repaired, 0 No -:

03Replaced,

_3 0Replacement 0Yes D 00 Repaired, 0 No 0 Replaced,

. OReplacement O Yes E :0 Repaired, 0 No 0 Replaced,

-_  ; - .- OReplacement O Yes F  ; 0 Repaired, 0 No 03Replaced,

._3 - - - * ,_. -O Replacement 0Yes Page 1 of 2

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work_ Reolaced valve
8. Tests Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. El Other 0 ExemptO Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks Test performed per MP/O/A/7700/045 (Applicable Manufacturers Data Reports to be attached)

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed N- X4 FL Grass JrQA Tech Specialist Date -/e4

' wvier or wners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have Inspected he components described in this Owner's Report during the period t3o / and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury property damage or a loss of any kind arising from or connected with this inspection. a

- rom e F Swan Commissions NCI524. N-I Inspectors re National Board, State, Province and Endorsements Date_

Page 2 of 2

4 Industrial Valves

. . Industrial Valve Operation OUALITY SYSTEMS DEPARTMENT XDresser Industries, Inc. PHONE: 318/640-6112 K-' P.O. Box 1430

  • Alexandria, Louisiana 71309-1430 - FAX: 318/640-6325

'CERTIFICATE OF COMPUANCEICONFORMANCE' Duke Power Company P. 0. Box 1002 Charlotte NC 28201-1002

Subject:

Your Order No. W06719-77 Dresser Order No. 15-39501-0 Gentlemen:

We hereby certify that the following listed valve furnished on the above.order has been manufactured, inspected and accepted in accordance with Dresser's engineering, design, material and quality requirements. We further certify that the attached documents, which are a part of the certification, are accurate and in compliance with the record requirements of this order.

We certify that this valve has been manufactured within the controls of Dresser's ASME B&PVC Quality Assurance Program for ASME B&PVC Section III valves, Revision 22, dated 6/12/89 (Certificate of Authorization No. N-1747, expiration dated May 20, 1992).

We certify that the packing contains less than 200 PPM Chlorides, less than 200 PPM Florides, less than 1000 PPM Leachable Sulfides and the material is free from mercury contamination.

Item No. 2 (1) 1-1/2' 1910-30F/S4-1-XLS1-NC3086 Serial No. TJ-17695 Tag No. MRV-023 National Board No. 1952 Set Pressure 150 PSIG Capacity 56 GPM Water Valve cleaned per CL-12, Rev. 7 Valve assembled per AS95, Rev. 3 Valve tested per PT-23, Rev. 0 , . . . .

. DUKE POWER COWANY I Valve packaged per PC-50, Rev. 6 II 10s,&. -kECC Pr,_ ti-C'.> I II -

Very truly yours, I 4.(.AREPF.ESENTA E*

John P. Watz l AT_ - -3 o'- !2 y4KI Principal Quality Assurance ngineer _ s _-

RY- Air

_/__W usE.

Billy E Hfir V 6 1 Date Documen v on.Specialist BEH:lp/39

IIndustrial ValesIQvi FOBI NV-I N CERTIFICATE HOLDERS' DATA ~REPR FOR SAFETY AND SAFElY RELJEF VALVES*

(AS REQUIRED BY THE PROVISIONS OF THE ASME CODE, SECTION III. DIV. 1)

1. I4ANUACTURED BY Dresser Induistries, Inc., Dresser Valve & Controls Div., Induistrial Valve Operations Intersection Hwy. 167 & 3225 North Alexandria. LA 71309-1430 (Name and Address CT h CerITIMiat Holder)
2. MANUACTURED FOR Duke Power Couvany. P. 0. BOX 1002. Charlotte NC 28201 (NaMe and AMdMSs Of Purchaser or owner)
3. LOCATION OF INSTALLATION Duke Power Co.. McGuire Nuclear Station, Cowans Ford NC 28078 t~ane and Address)
4. NC3086 1g52 1992.

(CHN) (Drawing No.) (Hati. Ord. No.) (Year Built)

S. VALVE 1-112-1910-30F/S4-1-XLSI-NC3086 IDENTIFYING NOS. TJ-17695 (Model Ho., 56ries Ho-.) (Ncertificate Holders' 5eri~a-FHo.)

TYPE Safety Relief CLASS 2 (Saiety, balety Relief; Pilot; -Power Actuated)

ORIFICE SIZE 0.3568 NOMINAL INLET SIZE 1-1/2 OUTLET SIZE 2 Inch Inch inch

6. SET PRESSURE(PSIGjL I50 RATED TEJ4PERATURE 200 STAMPED CAPACITY 56 GPM Water 9 10 %OVERPRESSURE BLOWDD0WN(PSIG)- NIA HYDROSTATIC TEST (PSIG) INLET **See Below OUTLET **See Below (Applicable to valves for closed systems only)
7. PRESSURE RETAINING PIECES SERIAL NO. OR MATERIAL SPECIFICATION IDENTIFICATION INCL. TYPE OR GRADE BODY ABT47 SA351 Or. C~F8M BONNET OR YOKE ABT09 SA351 Gr. CF8M SUPPORT RODS NOZZLE ABS74 SA182 Or. F316 DISC ABS96 SA479 Type 316 SPRING WASHERS ADJUSTING SCREW SPINDLE SPRING BOLTING STUDS S319 SA453 Or. 660 OTHER PIECES NUTS PE35 SA194 Or. 6 PIPE PLUG 21273 SA479 Type 316
    • Base 450 PSIG "**Bonnet 1125 PSIG Disc 4500 PSIG Nozzlea4500 PSIG SUPPLBMENT SHEETS IN FORM4 OF LISTS, SKETCHES OR DRAWINGS MAY BE USED PROVIDED (1) SIZE IS 8-1/2" X I1" (2) INFORMATION IN ITEMS 1 & 2 ON THIS DATA REPORT IS INCLUDED ON EACH SHEE, AND (3) EACH SHEET IS MWEERED AND HJJER OF -SHEETS IS RECORDED AT TOP OF THIS FORM.

C C.. (

Iy-/ -3

. IDUSVIAL VAVE

  • AND INSTRUMENT 0991 onISION SERIALIZATION RECORD yCsvyQ DRESSER ORDER NO. Ig-31s°cl-o DATE //- 4 .9/

CUSTOMER ORDER NO. 11-.&-1

-19 DRESSER ITEM NO. 2 PAGE / of /

VALVE TYPE I4'-II JZ/S- I L-L-AC3o8b VALVE SERIAL NO CUSTOMER BASE NOZZLE DISC ,. DISC HOLDER VALV SER NTAG NO. SERTL W.MBER SE L ER ER ! HEAT NUMBER.

r- . 7M e -1r tAhTA,- 5 i77 < Y /i786 3 BASE STUD BASE STUD NUT SPRING LOWER SPRING HEAT NUMBER HEAT NUMBER HEAT NUMBER WASHER HEAT NUMBER

- '9 6.

' C<lb CZ IsE -I q PE3S i1(?3 C ,4f 16PE-1O UPPER SPRING ADJUSTING SCREW BONNET SPINDLE HEAD WASHER HEAT NO. HEAT NUMBER ,SERIAL NUMBER HEAT NUMBER

. 4r. M'. __ _. . _/_ _-__ .

  • x QT AR --I Iavr aI'-7 (03 L9 Lsia 6,71 18 _ _y7. AO. r. If. o r. A . <r 0 7wn-l (T 7 O I I-L I I r I -

ALEXANDRIA,LOUISiANA VALVE TEST RECORD FUNCTIONAL TEST DRESSER ORDER NO. A7-K 9S'1- CUSTOMER ORDER NO. /

CUSTOMER it) V(181 RQ Wi ,,/&fgg VALVE TYPE // / CA -ff-3F/ //;. NO.

RIAL Ax ':/JZ K VALVE TAG NO. t4/4 2 A5 NATIONAL BOARD NO. _ _ _ _

Valve test (open, close, seat tightness) Is In accordance with Dresser procedure 7 D3 TEST GAGE S/N A 'O( 4)L CALIBRATION DATE ..JL2tC-L/

TEST MEDIA (44A TAr SET PRESSURE A'ri TEST STAND CDS_ __ _

(When applicable)

KOPENING PRESSURE_ _ _ _

CLOSING PRESSURE A C c/I- P-ar4

,L I BACK PRESSURE TESTED ACCEPTABLE AT 3 PSIG.

For Hydroset use In establishing set pressure:

STEAM PRESSURE HYDRAULIC PRESSURE TESTE DATE /2L 1A CUSTOMER REPRASENTATI___ DATE (When required)

AUTHORIZED NUCLEAR INSPECTOR _ __ DATE_________

(When required)

QA-01 32-0389 Cubma Prng,Inc 741

II( - m-  :@el CLEAN ROOM LOG DRESSER ORDER NO.. CUSTOMER QJUJ P-C.. X

  • DATE I I 1

CUSTOMER ORDER NO. V _ .(o1 . f/ -77 - QTY VALVE V S/N V \ - lto q S VALVE DESCRIPTION \' Ya - I N \ t)-3 ID/,S - Al V-lnX G SPECIFICATIONS: CvSL z \& J l 3 OPERATION DESCRIPTION: P o L \ Q LSAKQ NOTES:

171 Ma ACCEPTABLE E UNACCEPTABLE CLEAN ROOM.ATTENDANT -s INSPECTOR Q)..(L ci CUSTOMER REPRESENTATION .

QA0373/1089

. I 1

- 26151.(R-6) Forrn930.1A Rev.5 DUKE POWER COMPANY QUALITY ASSURANCE DEPARTMENT SUPPUER QUALITY ASSURANCE CERTIFICATION Name of SupplierBaSEl t I(tJtJ 51i 5,!c Date Address of Supplier Plant I4EEtfI 6 7Mill Per Order No. A+/-Q1 IJ77 i, 32A5NCRZi, * .. . . . ..A L-.

. . 6AJdA

.. Pq Duke item or Req. No. -

1-3gB9-

. l. spe Nof206/6- / Rev. 7 SuDDIler IDNos. i-ci7- 176 6 /

Description of Component(s) or Material(s) 7/ x 6Ff/ 1v/

O Attached Documentation covers all Components/Materials on Mlil Power Order.

lEtached Documentation covers partial shipment of Components/Materials on Mlil Power Order.

The ifng listed tests, Inspections and reports have been completed as required by the specificatlon:

sicai &Chemical Analysis 0 Major Repair Records & Charts IEHydro (Test Pressure - PSIG ) 0 Personnel Qualifications on Record O Design Report O Stress Report 0 Hem aJhstment O Radiographic Test O Ultrasonic Test 0 -netic Particle O enetrant Test O Repair NDE or atnainess p

  • Clpperating Test O Performance Curve ZAS AME Data Report L9Dlmenslonal Check O Deviation Record #
1) (C 6e 7J.ic,T- CA7T== <<,c ( , W Aily1 I- - -- - v. ----

2) 3)

I This certifies thatthe listed Component(s) or Material(s) conform to the reqirements of the aboferenced Duke Power documents Including all codes, standards, test requirements and Quren Invoked therein.

(See Instructions)

_ FORM NIS-2 OWNER'S REPQ2 FOR REPAIR / REPLACEMENT ACTIVITY (7 As Required By The Provisions Of The ASME Code Section Xl

1. Owner Address: Duke Power Comoanv la. Date Anrjl 10.2005

- . n

-I ROA Q-tlhvimh AfroAt rharleMn mr gAgni.inng - , Sheet 1 of I

2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 i32 03 OShared (specify Units __)
3. Work Performed By Duke Power Companv 3a. WorkOrder#:  : 98653418 Address: 526 S. Church Street. Chariotte NC 28201-1006 RVepai Orgmtanzl Jb J

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM #:_ N/A

4. (a) Identification of System: SM - Main Steam 4. (b) Class of System: B
5. (a) Applicable Construction Code: ASME IIG1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repair / Replacement Activity, 1995. 1996 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. IdentificatIon of Components:

- Column 1 . Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other tdentificatton Year Built Corrected, Removed, or ASME Code Stamped

._ _ _ _ _ _ _ _ _ _ __ . __ . __ . _ _ . .installed (yes or no)

A 0 Repaired, 0 No 2-SM-VA-1 . Atwood - Morrell 5-623 N/A . N/A .1976 0 Replaced,

._ ._ ._ ._ ... - 0 Replacement 0 Yes 0 Repaired, 0 No 0 Replaced,,

.3 Replacement 0 Yes C ... O Repaired, 0 No O Replaced,.

._ I_ .. . ., _ 0..

O Replacement 0 Yes D 0 Repaired,. 0 No 03 Replaced,

.______ . _  ; ... OReplacement OYes E 0 Repaired,. 0 No, 0 Replaced,

. -- .. ._ ._ . .3 OReplacement O Yes F . .. - .. . 0 Repaired,, 0 No

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _. Replaced,

. -.. . 5 . . .. 3 Replacement O Yes Page 1 of 2

ULi Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Welded sieve in stuffing box and replaced main popbet
8. Tests Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. El Other 0 ExemptO Pressure psig Test Temp. °F Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks Test performed per MP/0/A/7700/045 per task 15 (Applicable Manufacturees Data Reports to be attached)

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass Jr,A Tech Specialist Date

' owner or4Cmwers Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspe~t the components described In this Owners Report during the period I/0° to z///0/0; and state that to the best of my knowledge and belief, the Owner has peformed examifi ations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for ny personal injury property damage or a loss of any kind arising from or connected with this me F Swan- Commissions NC1524, N-I A/ Inspecto 31goNational sS Board, State, Province and Endorsements JDate 6 Page 2 of 2

(3 FORM NIS-2 OWNER'S RELAT FOR REPAIRS OR REPLACEMENTS As Recquired By The Provisions Of The ASME Code Section XI

('2

1. Owner Address: Duke Power Comoanv Ia. Date March 23. 2005

~w

-j-0 (hak .. h of-

'S 'J VIVS

  • l M ~ h~ b d

~.'SPIPL.

W.-IC.

Kin ')O')flA Mfl A

-P P-- - Sheet 1 of I.

2. Plant Address: McGuire Nuclear Station 12700 Hagers Ferry Road, Hunter'svilie. NC 28078 2a. Unit: 031 12 033 O3Shared (specify Units_ _ _ _ _ _ _ _ _ _ _
3. Work Performed By, Duke Power Compiany 3a. Work Order #:, 98653463 Address: 526 S. Church Street. Charlotte NC 28201-1006 R"WarOrgafnfzaton Job #

Type Code Symbol Stamp: N/A Authorization No.- NŽIA Expiration Date: N/AL 3b. NSM or MM #,__ NIA

4. (a) Identification of System: CF - Feedwater 4. (b) Ciass of System: B
5. (a) Applicable Construction Code: ASME III 1971 Edition,- Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. identitication of uornponents Rlepaired or Replaced and Replacement Com 3onents:___________

__Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8-Name of Comporent - Name of Mfg MNg Sertal No. Nationa Board No. O0lie Identification Year Built Repaired, Replaced, or ASME Code Stamped

_ _ _ _ _ _ _ _ _ __ __ _ _ _ __ ___ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _R eplace enK"ye o r n o)

A 2A Steam 03Repaired, 0 No Generator 'B&W- 770002 159 '~PO# C23355 1996 0 Replaced,

___ __ ___ __ _____ ___ __ ___ _ ___ __ ___ __ ~R eplacem ent 2 1 Yes B .0 Repaired,- 0 No 0 Replaced,

__0 _ __ Replacem ent 0 Yes 0 Repaired, 0 No 0 Replaced,'.

___ __ __ __ __ ____ __ __ __ _3 R eplacem ent 03Y es '

D 0 Repaired, ., 0 No

-0 Replaced,'

- .. Replacement E3Yes E 0 Repaired, 0 No 0 Replaced,

.. _ _ _ Replacement 0 Yes~

-FiJ Repaired; 0 No

__ __ _ _ _ _ __ _ __ __ _ _ _ __ __ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 R epla c e men t 0 Y es Page IIof 2 Revision 7

- - -- al-Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced one stud in the #4 hand hold flange
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. El Other 0 ExemptO Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks (Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A . -1 Signed S 1 ZL FL Grass Jr., QA Tech Specialist Date Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT gave ins te he components described In this Owners Report during the period Z 7/Q-to YZYF* S; and state that to the best of my knowledge and belief, the Owner has pefformed eamifatlons and taken corrective measures described in this Owners Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's A eport. Furthermore, nither the Inspector nor his employer shall be liable in any manner for

/tny personal injury o roperty damage or a loss of any kind arising from or connected with this

/inspection.

//

I Inspect r' erorme F Swan Commissions NC1524, N-I National Board, State, Province and Endorsements I

Page 2 of 2 Revision 7

(C FORM NIS-2 OWNER'S RL RT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl 4

I.

A.4.1--

%JvwnUIrffruurrass; M..t.- r!l-.-.

  • u~rsU FVwtI 'JVIIIdIIV -Y Ia. Date March 21. 2005 Sheet I of i
2. Plant Address: McGuire Nuclear Station 12700 Hagers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 02 -03 OShared (specify Units )__
3. Work Performed By: Duke Power Comoanv 3a. Work Order #: 98653488 Address: 526 S. Church Street. Charlotte NC 28201-1006 RepWr Orgarizeflon Job
  • Type Code Symbol Stamp: WA Authorization No. NiA Expiration Date: NA  : 3b. NSM or MM #._ N/A
4. (a) Identification of System: - NS - Containment Sprav 4. (b) Class of System: B
5. (a) ApplicableConstructionCode:ASME lll9ZlEditIon, SummerandWlnterAddenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for RepaIrs or Replacements: 1998.2000 Addenda (1992 through 1992 Addenda for Class MC and CC and thelr supports)
6. Identification of Components Repalred or Replaced and Replacement Coa onents: -- _ , - .  ;

Column 1 Column 2 . Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Oth Idenfication Year Built Repaired, Replaced, or ASME Code Stamped

_ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _R e p laceme n t (Yes or no )

A h Co 3 7 39 N. 17 0 Repaired, 0 No 2-NS-HX-0003 Delta S0uthem'Co 35005-73-3 3396 N/A' 1973 O Replaced,

__ _ __ ___ __ ___ _ ._ ._'. _ _ __ _ _ _ __ _ _ _ _ __ Rep lacem ent i Y es B 0 Repaired,, 0 No 0 Replaced,

._____. . ' . .. O Replacement 0Yes C 0 Repaired, 0 No- .

0 Replaced, ..

. ..... .- . .. . o Replacement 0 Yes D . 0 Repaired, . No, 0 Replaced,

- 0 Replacement 0 Yes E 0 Repaired, 0 No 0 Replaced,

_ _3 . . . . l O Replacement 0 Yes F . 0 Repaired,- i0 No

. .0 Replaced,

._ ._ ._ ._ .. . O Replacement 0 Yes Page 1 of 2 Revision 7

[I d

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced Bolting material on the end bell
8. Test Conducted:Hydrostatic EJ Pneumatic 0 Nom. Operating Press. 0 Other 0 ExemptlZ Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A (j-Y Signed FL Grass Jr.. QA Tech Specialist Date ____

Signeder or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by iSp CT have ins td the components described in this Owners Report during the period SL to . Z~S; and state that to the best of my knowledge and belief, the Owner has performed eianlinatlons and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this 4 inspection.

H Inspector's §n re ome F Swan Commissions NC1 524. N-I National Board, State, Province and Endorsements Date i//a,

-I Page 2 of 2 Revision 7

C FORM NIS-2 OWNER'S RLAT FOR REPAIRS OR REPLACEMENTS As Reaulred By The Provisions Of The ASME Code Section Xl

('

1. Owner Address: Duke Power Companv 1a. Date 04104/2005 3

526 S. Church Street. Charlotte. NC 28201-1006 - Sheet 1 of 1 fI

2. Plant Address: McGuire Nuclear Station -

12700 Hagers Ferry Road; Huntersville. NC 28078 2a. Unit: 01 Ei2 03 OShared (specify Units -

3. Work Perfomied By: Duke Power Companv 3a. Work Order # : 98656568/06 Address: 526 S. Church Street. Charlotte NC 28201-1006 - Repair Orgaizaltin Job #

Type Code Symbol Stamp: _A Authorization No. WA Expiration Date: N!A 3b. NSM dr MM #: ME2o6282

4. (a) Identification of System: NS 4. (b) Class of System: B  ;
5. (a) Appiicable Construction Code:ASME III 19Z1 Edition, Summer and Winter Addenda, NIA Code Cases (b) Appiicable Edition of Section Xl Utilized for Repairs or Replacements: 1998.2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Components Repaired or Replaced and Replacement Con ponents: -- _ :II _

= Column 1  : Column 2 Column 3 Column 4 . Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mftg  ; Mfg Serial No. National Board No. Otew Identification Year Built Repaired. Replaced, or ASME Code Stamped

___ ___ ____.. .- ________ _ Replacem ent (yes or no) -

A CIRepaired,0 No NS Piping DLuke Power ;. I N/A .. 69  : 2NS 1982 0 Replaced,

_ __ OReplacement iYes-B 0 Repaired, 0 No 0 Replaced,

._ _._ _0 Replacement 0 Yes -

C0 Repaired,. 0 No 0 Replaced,

.___3 0Replacement O Yes D 0 Repaired, 0 No 0 Replaced,

__ 0 Replacement 0 Yes E . - - 0 Repaired, 0 No 0 Replaced,

. _:- -. 0 Replacement 0 Yes F 0 Repaired,: 0 No 0 Replaced,-

____3 - .  ; - - 0Replacement 0 Yes Page 1 of 2 Revision 7

L-1 Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Repaired welds, replaced piping per ME200282. 'B Train"
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. F23 Other 0 Exempto Pressure 11 nsig Test Temp. 71.1 OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks (Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signeo F.R. Sorrow. QA Tech Support Date 4/04, 2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HB Cl have ins d the components described in this Owner's Report during the period soto

~4LY1 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury r property damage or a loss of any kind arising from or connected with this inspection.

-fgrome F Swan Commissions NC1524. N-I Inspect ure National Board, State, Province and Endorsements Page 2 of 2 Revision 7

FORM NIS-2 OWNER'S RELAT FOR REPAIRS OR REPLACEMENTS As Requlred By The Provislons Of The ASME Code Section XI C

1. Owner Address: Duke Power Comranv 1a. Date 04/04/2005 526 S. Church Street. Chaflotte.'NC 28201-1006 Sheet 1 of 1
2. Plant Address: McGuire Nuclear Station I t

Z 12700 Haders Ferry Road. Huntersville. NC 28078 I 2a. Unit: 01 iW2 03 OShared (specify Units -

3. Work Performed By: Duke Power Comoanv 3a. Work Order #: 98656569/04 Address: 526 S. Church Street. Charlotte NC 28201-1006 Repafr Orgalzaon Job #

Type Code Symbol Stamp: NAA Authorization No. I Expiration Date: NIA 3b. NSM or MM #: ME200282

4. (a) Identification of System:- NS 4. (b) Class of System: B  ;
5. (a) ApplicableConstructionC6de:ASMEill.191Edition, SummerandWinterAddenda, N/A Code Cases (b) Applicable Edition of Section XI UUlized for Repairs or Replacements: 1998.2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

. ' .i , . . '_.. . .

15. iaenifcation or L;omponents Repaired or Replaced ana Heplacement Com onents:

_ Column 1 . Column 2 .Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of MfMW g Serial No. National Board No. Otte Iden.ication Year Built Repaired, Replaced, or ASME Code Stamped

_ __ _ _ _ __ __ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _R eplacem ent (yes or no)

A .Repaired, 0 No NS Plping .. Duke Power N/A 69 2NS 1982 0 Replaced,

_OReplacem . . . ent ElYes B 0 Repaired, 0 No 03Replaced,

______  : ____ O Replacement 0 Yes C 0 Repaired, 0 No..-

03Replaced,-,

._ ._ .0 Replacement 0 Yes D .. 0 Repaired, 0 No

.,0 Replaced,-

_ . . . -. . ; . .O0 Replacement 0 Yes E . ., . 0 Repaired, 0 No

':.-* _ - ." ._ ._ . 0..Replacement 0 Yes F 0 Repaired; 0 No 0 Replaced,

._ -_ ._ . ... .. 0 Replacement 0Yes Page 1 of 2 Revision 7

11-I Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Repaired welds, replaced niping per ME200282. "A Train"
8. Test Conducted:Hydrostatic l Pneumatic 0 Nom. Operating Press. El Other E ExemptO Pressure 9 psig Test Temp. 69.9 OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks (Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed*4mi= J F.R. Sorrow. QA Tech Support Date 4104, 2005 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT. have ins d the components described in this Owner's Report during the period 2F2o2 M5 to  ; and state that to the best of my knowledge and belief, the Owner tas performed exarhinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inju or property damage or a loss of any kind arising from or connected with this spection.

m erome F Swan Commissions NC11524. N-l inspector's M6 ture National Board, State, Province and Endorsements 6 Date Page 2 of 2 Revision 7

FORM NIS-2 OWNER'S RLRT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xi (7-

- 1. Owner Address: Duke Power Comoanv 1a. Date 03/28/2005 526 S. Churh Street. Charlotte. NC 28201 -1006 - .. I Sheet 1 of I

2. Plant Address: McGuire Nuclear Station 12700 Hagers Ferry Road; Huntersville. NC 28078 2a. Unit: 01 02: 03 0 Shared (specify Units !_)
3. Work Performed By: Duke Power ComDanv - *3a. Work Order #: 98663764 Address: 526 S. Church Street. Charlotte NC 28201-1006 Replr Orgarlalon Job #

Type Code Symbol Stamp: SA Authorization No. N/A Expiration Date: WA 3b. NSM or MM #: N/A A

flIr,1dionfifiptlofnn nf li~otgam* MV I A thl l"na^ ,J vOtm- R

5. (a) Applicable Construction Code: ASME III 19Zg. Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identmcation OT Uomponents Repaired or Heplaced and Repiacement Com onents:

_ Column 1 Column 2- Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg MMgSerial No. National Board No. Otwer ication Year Built Repaired. Replaced, or ASME Code Stamped

__ ._ ..  ; Replacement (yes or no)

A - 0 Repaired, 0 No

2NV-93 D.TE-09047 291 N/A 1978 Replaced;.

__ -_;_-_._-_-_._I _ Replacement ff Yes B 0 Repaired, 0 No 0 Replaced,

.:  : 0 Replacement 0 Yes C :3 0 Repaired, 0 No-0 Replaced,

_ -_ - - :0 Replacement 0 Yes' D 0 Repaired, 0 No

- .. 0 Replaced,

_ O Replacement O Yes' E 0 Repaired, 0 No 0 Replaced,-

.3 .-- _ OReplacement O Yes F .  ; 0 Repaired,- 0 No 0 Replaced,

. _ . - O0 Replacement 0Yes  : -

Page 1 of 2 Revision 7

uL-I Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced Disc and studs and nuts in Inlet flange
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 0 ExemptEl Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks (Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A-_

Certificate of Authorization No. N/A Expiration Date N/A Signed c rF - F.R. Sorrow. QA Tech Support Date 03/28, 2005 Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hgp CL have inspqctedlhe components described in this Owner's Report during the period

,M to iA4 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal inju or property damage or a loss of any kind arising from or connected with this inspection. /

Jerome F Swan Commissions NC1524. N-I Inspector's lgkturjs National Board, State, Province and Endorsements Date Page 2 of 2 Revision 7

C FORM NIS-2 OWNER'S RL..hT FOR REPAIRS OR REPLACEMENTS IIj; As Required By The Provisions Of The ASME Code Section Xl

1. Owner Address: Duke Power Comwanv . la. Date 04/06/2005-526 S. Church Street. Charlotte. NC 28201-1006 Sheet I of 1 p.
2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road, Huntersville. NC 28078 2a. Unit: 01 02J2 03 OShared (specify Units )
3. Work Performed By: Duke Power ComDanv *3a. Work Order # : 98663764/13 Address: 526 5.Church Street. Chariotte NC 28201-1006 Repir Orga Job #

tizaton Type Code Symbol Stamp: N Authorization No. NIA Expiration Date: N/A 3b. NSM or MM #: NIA

4. (a) Identification of System: NV 4. (b) Class of System: B -
5. (a) Applicable Construction Code: ASME lIl 19fl Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repalrs or Replacements: 1998, 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

A

6. Idenuifcation of Componenrts Repairea or Replacea and Replacement Com onents:

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of CoImpornet Name of Mfg Mfg Serial No. National Board No. Otwer Identification Year Built Repaired. Replaced, or ASME Code Stamped

._ ._ -_ ._._._. ._._._... _. _ . Replacement (yes or no)

A ..- Repaired, ENo, 2MCR-NV-4217 Duke Power - N/A N/A N/A N/A 0 Replaced,

. .  ;  : 0Replacemnent 0 Yes B 03Repaired,. 0 No

O Replaced,
  • - . 0Replacement 0Yes C 0 Repaired, O No_

0 Replaced, O Replacement 0 Yes D 0 Repaired, 0 No 03Replaced,

. -  : 0 Replacement 0 Yes E 03Repaired, 0 No

- .Replaced,

._ -_ ._ * -.. 0 Replacement 0 Yes F . . 0 Repaired, 0 No 0 Replaced, 0

3 Replacement 0Yes Page I of 2 Revision 7

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Cut and rewelded item 1 with full penetration weld
8. Test Conducted:Hydrostatic a Pneumatic 0 Nom. Operating Press. 0 Other 0 ExemptiJ Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure pSig Test Temp. OF
9. Remarks (Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A (

Certificate of Authorization No. N/A Expiration Date N/A Signed Ap/4 Ax-e' F.R. Sorrow. QA Tech Support Date 04/06, 2005 OWer or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have the components described in this Owner's Report during the period to

_l__1,havei; and state that to the best of my knowledge and belief, the Owner has performed examrnations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injurpor property damage or a loss of any kind arising from or connected with this

//inspection.D l ome F Swan Commissions NC1524. N-I Inspector'S ture National Board, State, Province and Endorsements Date A Page 2 of 2 Revision 7

'C FORM NIS-2 OWNER'S RLRT FOR REPAIRS OR REPLACEMENTS As Reauired By The Provisions Of The ASME Code Section Xl

(;_,
1. Owner Address: Dtike Power Comranv 1a. Date 03/31/2005
  • - . 526 S. Church Street. Charlotte. NC 28201-1006 Sheet 1 of I
2. Plant Address: - McGulre Nuclear Station 12700 Hacers Ferry Road. Huntersville. NC 28078 e (U . .s 2a. Unit: 01 0i2 03 O3Shared (specify Units )1
3. Work Performed By Duke Power Companv - 3a. Work Order # : 98664169/01 Address: 526 S. Church Street. Charlotte NC 28201-1006 Repalr Organftn Job * -

Type Code Symbol Stamp: Authorization

- No. N/A Expiration Date: N/A '3b. NSM or MM#: N/A A- (5a lrlontiflirtinn of Rvqtcamri NV' 4A- (hi Clasq of Svstem: B .:

5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda,: N/A Code Cases (b) Appiicable Edition of Section XI Utilized for Repairs or Replacements: 1998.2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Components Repaired or Replaced and Replacement Corn onents: _ _--

_ Column 1 . Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Compornt. Name of Mfg Mfg Serial No. National Board No. Oter Identification Year Built Repaired, Replaced, or ASME Code Stamped

.. . , ,- . . .*- Replacerent (yes or no)

A 0 Repaired, 0 No Valve 2NV-1 56 Dresser TD36315 408 N/A 1978 0 Replaced,

____- ___ .. __ ._. . ;. . IM Replacement EYes B 0 Repaired, 0 No O Replaced,

._ . . . . . . . .. O Replacement 0 Yes C 0 Repaired, 0 No  ;

- . 0.Replaced,

.___. ___ . . .. .. .__. .0 Replacement 0Yes D 0 Repaired, 0 No

.___ . . .  : .  : . . . . . -  ;. '0 R eplaced,'

___._.___,_. . . . . 0 Replacement 0 Yes -

E . 0 Repaired, 0 No 0 Replaced,

._ ._ ._ . - . ..  : .. .. 0 Replacement 0Yes F . 0 Repaired,, 0 Nor 03Replaced,:-

._____3  : . . . . 0Replacement 0 Yes Page 1 of 2 Revision 7

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced disc.
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 0 ExemptrE3 Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks (Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A f"..1 I Certificate of Authorization No. N/A Expiration Date N/A Signed F.R. Sorrow. QA Tech Support Date 03/31, 2005 Owner or Owner's Designee. rtle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have in;peItqd the components described in this Owners Report during the period

^31 z IJ2 to .//t5; and state that to the best of my knowledge and belief, the Owner has perormed exam nations and taken corrective measures described in this Owners Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury r property damage or a loss of any kind arising from or connected with this inspection.

7' Inspector's ig re rome F Swan Commissions NC1524. N-I National Board, State, Province and Endorsements Date , 5 Page 2 of 2 Revision 7

C FORM NIS-2 OWNER'S RLfrT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl CI'.

1. Owner Address: Duke Power Comoanv 1a. Date 04/07/2005

.526 S. Church Street. Charlotte. NC 28201-1006 Sheet 1 of I

2. Plant Address: McGuire Nuclear Station 12700 haaers FerrV Road. Huntersville. NC 28078 2a. Unit: 01 02 03 OShardd (specify Units )
3. Work Performed By Duke Power Companv 3a. Work Order # : 98665743-05 Address:  ; 526 S. Church Street. Charlotte NC 28201-1006 Repair Organrzeion Job C Type Code Symbol Stamp: N Authorization No. NIA Expiratlon Date: N 3b. NSM or MM #: N/A
4. (a) Identification of System: -_ NV 4. (b) Class of System: A
5. (a)' Applicable Construction Cbde: ASME Ill 19Z7 Edition Summer and Winter Addenda, N/A Code Cases.

(b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Replaced and Replacement Com onents: -

Column 1 Column 2 Column 3 Column 4  ;,Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identification Year Built Repaired. Replaced, or ASME Code Stamped

__ ._  : ._..Replacement (yes or no)

A  ; . ORepaired, El No 2MCR-NV-4379 Duke Power N/AN/A Hanger N/A 0 Replaced,

.__ .__.__ .. .. . . __ . . 0 Replacement 0 Yes B 0 Repaired,' INo.

2MCR-NV-4380 Duke Power N/AN/A Hanger N/A 0 Replaced,

.__ .__. - . _. . . . . El Replacement 0Yes C 03Repaired, 0 No 0 Replaced,

. . . .  ; . . . . 0 Replacement 0Yes, D 03Repaired, 0 No 0.3 Replaced,

._ __ __ .  : _._.. _.. _._ .0 Replacem ent 0Yes' E 0 Repaired, 0 No O3 Replaced,

. .. .;  : . x - .0 Replacement 0 Yes F 0 Repaired,. 0 No 0 Replaced,;

_________________ .____ .__ __ ._ _ 0..3 R eplacem ent 0lY es Page I of 2 Revision 7

11-HU Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced item 6 on 2MCR-NV-4379. Replaced item 5 on 2MCR-NV 4380
8. Test Conducted:Hydrostatic 0 Pneumatic 0l Nom. Operating Press. 0 Other 0 ExemptiZ Pressure psig Test Temp. OF Pressure psig Test Temp. _ F Pressure psig Test Temp. .F
9. Remarks (Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signe j > A l.w-' F.R. Sorrow. QA Tech Support Date 04/07, 2005 Owner or Owner's Designee, TWe CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HS8 CT have ined the components described In this Owners Report during the period 312Zt2S to ...2/  ; and state that to the best of my knowledge and belief, the Owner ha pe omed exan1finations and taken corrective measures described in this Owner's Report in 4 accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for ny personal injury property damage or a loss of any kind arising from or connected with this nspection. )

ome F Swan Commissions NC1524. N-I o re National Board, State, Province and Endorsements C Dat <//s Page 2 of 2 Revision 7

C- FORM NIS-2 OWNER'S RE,-hT FOR REPAIRS OR REPLACEMENTS C_

As Required By The Provisions Of The ASME Code Section XI i  :.

1. Owner Address: Duke Power Comranv la. Date 03/29/2005 526 S. Church Street. Charlotte. NC 28201-1006 Sheet 1 of 1
2. Plant Address: McGulre Nuclear Station-12700 Haders Ferry Road. Huntersville, NC 28078 2a. Unit: '01 112-' 03 OShared (specify Uhits' -
3. Work Perfomied By Duke Power Companv 3a. Work Order # : 98670826/01 Address: 526 S. Church Street. Charlotte NC 28201-1006 Repair OrgaIzatn Jb Type Code Symbol Stamp: MIA Authorization No. -N/A Expiration Date: N/A 3b. NSM or MM #: N/A
4. (a) Identification of System: ' NV  : 4. (b) Class of System: B
5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda,  ! NiA ' Code Cases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Compon nts Repaired or Replaced and Replacement Corn onents: . - _ _i

= Column 1 . Column 2 7. Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Otwer Identification Year Built Repaired. Replaced, or ASME Code Stamped

___ __ ___ __ __ _____ __ ___ __ __Replacem ent (yes or no)

A . - 0 Repaired, No Valve 2NV-10 'Crane-Aloyco A0586 21 N/A 1973 0 Replaced,

.________ .__ .__ .__ * .. . .. Replacem ent !E3Yes B 0l Repaired,_ 0 No 0 Replaced,'

_________________ .______ . 0 Replacement O Yes C 0 Repaired, O No-0 Replaced, -

r _____ ._ ,. .. .' , 0 Replacement 0 Yes '

D 0 Repaired, 0 No 0 Replaced, -

. ._  : .. _ _ _ _ _ _ _  :-_ _ _ _ _ _ 0..Replacement 0 Yes E . - 0 Repaired, 0 No 03Replaced,

._ . _. _. _._;. O Replacement O Yes F 0 Repaired,- 0 No 0 Replaced,

_ .. .. 0 Replacement 0 Yes Page 1 of 2 Revision 7

uL-I Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced body to bonnet nut
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 0 Exempt[J Pressure psig Test Temp. OF Pressure _psig Test Temp. -F Pressure psig Test Temp. OF
9. Remarks (Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed F.R. Sorrow, OA Tech Support Date 03t29 2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by ISBCT Shave inspectedthe components described in this Owner's Report during the period 3/:22/ 2s to 13 and state that to the best of my knowledge and belief, the Owner hs peiormed exfminhtions and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection. D t1 / -, erome F Swan Commissions NC1524, N-I

/Inspectorsj National Board, State, Province and Endorsements C Date 13/

Page 2 of 2 Revision 7

C, FORM NIS-2 OWNER'S RE JRT FOR REPAIRS OR REPLACEMENTS As ReauIred By The Provisions Of The ASME Code Section Xl C;,.

1. Owner Address: Duke Power Comoanv la. Date 03121/2005 '

526 S. Church Street, Charlotte, NC 28201-1006 Sheet 1 of 1

2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferr, Road. Huntersville. NC 28078 2a. Unit: 01 02 03 OShared (specify Units )
3. Work Performed By. Duke Power Companv 3a. Work Order # : 98674357/01 Address: 526 S. Church Street. Charlotte NC 28201-1006 Repir Organizon Job #

Type Code Symbol Stamp: WA Authorization No.. NtA Expiratlon Date: N/A 3b. NSM or MM 4i# ...- NtA

4. (a) Identification of System: NV 4. (b) Class of System: B
5. (a) Applicable Construction Code: ASME lil 197 EditIon, Summer and Winter Addenda, N/A I-I Code Cases: -'

(b) Applicable Edition of Section' Xl Utilized for Repairs or Replacements: 1998.2000 Addenda (1992 through 1992 Addenda for Class MC and CC and thelr'supports)

6. Identification of Components Repaired or Replaced and Replacement Corn onents: _ ____

_ Column 1 . Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mtg . Mfg Serial No. National Board No. Other Identification Year Built Repaired. Replaced, or ASME Code Stamped

,__ .__ ,_ ._._._,_._ .Replacement (Wes or no)

A 03Repaired, O No Valve 2NV-477 . Walworth'; A0596 60 N/A 1973 0 Replaced;

. - . . 0 Replacement 0 Yes B 0 Repaired, 0 No 0 Replaced,

. - .. . - . 0 Replacement 0 Yes' C ' 0 Repaired, O No

' . -0 Replaced,'

_ ': - . ' ' OReplacement O Yes D . . - 0 Repaired, 0 No

- . . -' '. O Replaced,

. _ _ :_3 ;- ,Replacement O Yes E 0 Repalredi O No-03Replaced,

_ ' 0 Replacement 0 Yes F  ; 0 Repalred, 0 No 0 Replaced,'.

. 0 3 Replacement 0Yes Page 1 of 2 Revision 7

- lo l Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced 16 bonnet to body nuts
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. Cl Other 0 Exempt0l Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks (Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed G o, F.R. Sorrow. OA Tech Support Date 03/21, 2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HISS C have ins td he components described in this Owner's Report during the period to-ande, state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xi.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, either the Inspector nor his employer shall be liable in any manner for any personal injury o roperty damage or a loss of any kind arising from or connected with this A~spection. v me F Swan Commissions NC1524. N-I

~specto~ S National Board, State, Province and Endorsements

/Date / f2 Page 2 of 2 Revision 7

C FORM NIS-2 OWNER'S RCjRT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xi

1. Owner Address: Duke Power Comranv 1a. Date 03/21/2005

. . Cnd 0 .d - I i4.Mf KIP ',AoIJInnM Sheet 1 of I

. I

2. Plant Address: M6Guire Nuclear StationI 12700 HagersFerrv Road. Huntersville. NC 28078 2a. Unit: 01 02 03 0Shared (specify Units )
3. Work Performed By: Duke Power Com anva- 3a. Work Order # : 98674358/01 Address: 526 S. Church Street. Charlotte NC 28201-1006 I .

Repair Organization Job #

Type Code Symbol Stamp: AQAuthorization No. 9 Expiration Date: N/A 3b. NSM or MM #: N/A

4. (a) Identification of System: NV 4.* (b) Class of System: B
5. (a) Applicable Construction Code: ASMEIII 1971 Edition, Summer and Winter Addenda, N/A. Code Cases (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. identincatlon of Components Hepaired or Replaced and Hepiacement com onents:

l Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Narne of Component - Name of Mfg M.fg Seral No. Naional Board No. Otler Identification Year Built Repalred, Replaced, or ASME Code Stamped

, Replacement (yes or no)

A . . 0 Repaired, 0 No Valve 2NV-476 - Waiworth, . A0595 47 N/A 1973 0 Replaced,

.  : -_ E0 Replacement 0 Yes B 03 Repaired, 0 No

, .0  : Replaced,

_ - 0 Replacement 0 Yes C 0 Repaired, 0 No

O Replaced,

._ _ .- - 0 Replacement 0 Yes D 0 Repaired, 0 No 03 Replaced,.

________________ ___________ _ Replacem ent 0-3 0 Yes E 0 Repaired, 0 No 03 Replaced,

_1_3
- ,: -_- ;0OReplacement 0Yes F - 0 Repaired, 0 No 0 Replaced,

. 0 Replacement 0Yes Page 1 of 2 Revision 7

U1 Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced 16 bonnet to body nuts
8. Test Conducted:Hydrostatic 0 Pneumatic El Nom. Operating Press. 0 Other 0 Exempt[E Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed F.R. Sorrow. OA Tech Support Date 03/21, 2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by 111 CT/have instedthe components described in this Owner's Report during the period 3J / t W to a , and state that to the best of my knowledge and belief, the Owner hag performed exhminftions and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in-the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inju rr property damage or a loss of any kind arising from or connected with this Inspection. }

Yl/.erome F Swan Commissions NC1524, N-I Inspectorjnhyltyre National Board, State, Province and Endorsements I

Page2of2

.jIRevision 7

C, FORM NIS-2 OWNER'S RC-RT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xi

1. Owner Address: Duke Power Comoanv la. Date March 27. 2005

. .. '7 KO Chi iryh Qfrant ehndfntfb Mr' 2RAt1:tz^MA Sheet 1 of 1 Mc-ulre Nuclearsl St .v--at on ---

2. Plant Address: McGuire Nuclear Station.

.12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 0i1 02 03 0-Shared (specify Units )

3. Work Performed By-.. Duke Power Corroanv. 3a. Work Order #:. 98684559 Address: 526 S. Church Street. Charlotte NC 28201-1006 RepirOrgantzalon Job #

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: N/A 3b. NSM or MM #: N/A

4. (a) Identification of System: Ni - Safety Inlection :, 4. (b) Class of System: B
5. (a) Applicable Construction Code: ASMEIII 19Z1 Edition, Summer and Winter Addenda, WN/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Components Repaired or Replaced and Replacement Coin onents: - -

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Comporent . Name of Mtg Mig Serlal No. NatonalBoard No. Otwer Identifion Year Built Repaired, Replaced. or ASME Code Stamnped

_ Replacerent (yes or no)

A ORepaired, O No 2-NI-VA-334 Walworth. Al 192 563 N/A, 1974 E Replaced,

._ ._ . .. . .. . ... 0Replacement El Yes B . 0 Repaired, 0l No 03 Replaced,

___3 : .  :- . . . . .0 Replacement 0Yes C 0 RepaIred,- 0 No 0 Replaced,'-

._ .  :. . - . .O Replacement 0Yes D ORepalred, O No.

. 0 Replaced,

__.____ _._._._.._._ _._.._._._ . 0OReplacem 3 ent 0Yes E . 0 Repaired, 0 No 03 Replaced,

._3 . - -..Replacement O 0Yes F 0 Repaired, 0 No,

- .0 Replaced,

_  : -- . - ._.:  : . 0 Replacement 0 Yes

- Page I of 2 Revision 7

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced bolting material in the bonnet
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. El Other 0 ExemptO Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks Test performed per task 13 of this work order.

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed. 4 Zier or FL Grass

, Jr. QA Tech Specialist ers Designee, Title Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSiCTsjhave inspct he components described in this Owners Report during the period 119=7S to t and state that to the best of my knowledge and belief, the Owner his pehformed examinatlons and taken corrective measures described in this Owners Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, ither the Inspector nor his employer shall be liable in any manner for ny personal injury or roperty damage or a loss of any kind arising from or connected with this lisp cion.

me F Swan Commissions NC1524, N-I np ' tNational Board, State, Province and Endorsements Page 2 of 2 Revision 7

c FORM NIS-2 OWNER'S REPLS FOR REPAIR / REPLACEMENT ACTIVITY As Required By The Provisions Of The ASME Code Section XI C.

1. Owner Address: Duke Power Comoanv Ia. Date Adril 10. 2005

- - 526 S. Church Street. Chadotte.NC 28201-1006 -7? - Sheet 1 of 1

2. Plant Address: MW(Itifr Nir.Idnar 5~ts~tinn.'

12700 Hagers Ferrn Road. Huntersville. NC 28078 2a. Unit: C01 02 03 O3Shared (specify Units )

3. Work Performed By: Duke Power Comoanv 3a. Work Order#: - 98701859 Address: 526 S. Church Street. Charlotte NC 28201-1006 Repair Organization Job
  • Type Code Symbol Stamp: WA Authorization No. NA Expiration Date: N/A 3b. NSM or MM #-_ N/A
4. (a) Identification of System: SM - Main Steam : 4. (b) Class of System: B
5. (a) Applicable Construction Code: ASMEIII 19719 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XUtilized for RepaIr / Replacement Activity 1995. 1996 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Components: -

Column 1 Column 2 . Column 3 Column 4 Column 5 Col 6; Column 7 Column 8 Name of Component Name of Mtg Mfg Serial No. National Board No. Other Identification Year Built Corrected, Removed, or ASME Code Stamped

.,_._'_. ._Installed ' (Yesor no)

A . 0 Repaired, 0 No 2-SM-VA-7 Atwood - Morrell 8-623 . N/A N/A .1976 0 Replaced,

._ . Replacement E Yes' B 03 Repaired, 0 No

- .0 Replaced,-

_R __-_:_._ _;_; O fleplacement 3 Yes:

C . ORepaired,. O No

. .; 0 Replaced,

. . 0 Replacement 0 Yes D -3 ORepaired, No

- :.. - -  :; O0 Replaced,

. 0 Replacement 0Yes -

E 0 Repaired, 0 No 0 Replaced,

- 0 Replacement 0Yes F  ; - -  :  ; 0 Repaired, 0 No 0 Replaced,

. - - : , 0 Replacement 0Yes Page I of 2

ail-Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Work Welded sIeve in stuffing box and replaced main poppet
8. Tests Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 0 ExemptO Pressure psig Test Temp. -OF Pressure psig Test Temp. °F Pressure psig Test Temp. OF
9. Remarks Test performed per MP/O/N/7700/045 per task 27 (Applicable Manufacturer's Data Reports to be attached)

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A ,

Signed FL Grass JrQA Tech Specialist Date ___A//2yor Owner or'Ower's Designee, Tite CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inspected the components described in this Owner's Report during the period 3/oto 4/1o  ; and state that to the best of my knowledge and belief, the Owner has performed inations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury r property damage or a loss of any kind arising from or connected with this in ton'ome F Swan Commissions NC1524. N-I nsp National Board, State, Province and Endorsements

( J Date /Ac Page 2 of 2

C- FORM NIS-2 OWNER'S RLIRT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

  • 1. Owner Address: Duke Power Comoanv la. Date March27.2005 526 S. Church Street. Charlotte. NC 28201;1006 Sheet 1 of I
2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 EC2 03 OShared (specify Units_ _' _ )
3. Work Performed By: 'Duke Power Comoanv  :- - 3a. Work Order #: 98709187 Address: 526S. Church Street. Charlotte NC 28201 1006 Repar Organizati Job
  • Type Code Symbol Stamp: N/A Authorization No. NIA Expiration Date:' N/A - '3b. NSM or MM #: N/A
4. (a) Identification of System: NV - Chemical and Volume Control 4. (b) Class of System: B
5. (a) ApplicableConstructionCode:ASMEIII .1971 Edition, Summer and Winter Addenda, N/A CodeCases (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Comnponents Repaired or Replaced and Re1placeriient Corn onents: -

= Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Compont Name of Mfg Mfg Serial No. National Board No. Other Idenfcon Year Buitt Repaired,Replaced or ASMECodeStamped

_ _ _ __ _ _ _ __ __ __ _ _ _ __ _ _ ___ _ _ _ __ _ _ _ _ _ _ _ _R eplacem ent (Y m or no)

A 0 Repaired, E No 2-MCA-NV-7011 Duke Power - 17401 N/A N/A N/A El Replaced,

.____ _____ _____ .:_____ .__ . 0.Replacement 0 Y es B . 0 Repaired, Cl No 2-MCA-NV-7011 Duke Power . 21082 N/A N/A. N/A 0 Replaced,,

. . Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,- .

. .. - - . .. . . .. . . . Cl Replacement 0 Yes D 0 Repaired, O No.

. Replaced,

.. ._________ _. 0 Replacement 0 Yes E 0 Repaired, 0 No

. .0 Replaced,

. . . . .0 Replacement 0 Yes F 0 Repaired; 0 No 0 Replaced,-

. , .0 Replacement 0 Yes:

. Page 1 of 2 Revision 7

.. I Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced snubber
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 0 ExemptOl Pressure psig Test Temp. .F Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks (Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A H

Signed -, tina FL Grass Jr., QA Tech Specialist Date Owner Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HS3 CT have i tedthe components described in this Owner's Report during the period 3IZL/ o 1Q. I; and state that to the best of my knowledge and belief, the Owner has perormed damidatlons and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore neither the Inspector nor his employer shall be liable in any manner for ny personal injury property damage or a loss of any kind arising from or connected with this Ispection.

rome F Swan Commissions NC1524. N-I National Board, State, Province and Endorsements

(

Page 2 of 2 Revision 7

f. FORM NIS-2 OWNER'S RLRT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl C .
1. Owner Address: Duke Power Comoanv la. Date March 6. 2005 526 S. Church Street. Charlotte; NC 28201-1006 Sheet 1 of - 1
2. Plant Address: I McGuire Nuclear Station - - - >.

12700 Hagers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 02 03 OShared (specify Units )

3. Work Performed By. Duke Power Comoanv 3a. Work Order#: 98709192 Address: 526 S. Church Street. Charlotte NC 28201-1006 Repar Ofguiztlon Job X Type Code Symbol Stamp: WA Authorization No. W/A Expiration Date, NIA 3b. NSM or MM #, N/A
4. (a) Identification of System: SM- Main Steam - 4. (b) Class of System: B
5. (a) ApplicableConstructionCode:ASMEi1 Z19Editon, SummerandWinterAddenda, N/A . Code Cases (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1998.2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Components Repaired or Replaced and R6elacement Corn onents: -_- _:

l Column 1 Column 2' Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Compont - Name of Mfg - Mg Serial No. National Board No. Other Identification Year Built Repaired. Replaced, or ASME Code Stamped

._. ._. ._.._,._- Replacement (es or no)

A 0 Repaired, 0 No 2-MCA-SM-H283 Duke Power . 33921 N/A N/A 0 Replaced,

._ _ _ ;_-  :-I OReplacement 0YWS B  ; - - -O 0 Repaired, 0 No  ;

2-MCA-SM-H283 Duke Power 17331 N/A- N/A 0 Replaced,:

t0Replacement 0 Yes C 0 Repaired, 0 No 03Replaced,

._ - _ - ;0 Replacement 0Yes D 0 Repaired,, O No 0 Replaced,.

- . . l -0 Replacement 0Yes E 0 Repaired, 0 No 0 Replaced,

. _. .  :: . 0 Replacement 0 Yes F ,

-: 0 Repaired, 0 No 0 Replaced, 03 Replacement 0Yes Page I of 2 Revision 7

La- l Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of ReDlaced snubber
8. Test Conducted:Hydrostatic 0 Pneumatic E Nom. Operating Press. 0 Other 0 ExemptEl Pressure psig Test Temp. _ F Pressure psig Test Temp. OF Pressure psig Test Temp. _ F
9. Remarks (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass Jr., QA Tech Snecialist Date Owner gelOwner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by CT have te the components described in this Owners Report during the period

/ to 3/7 and state that to the best of my knowledge and belief, the Owner has performed exknirfations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in the Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injuH or property damage or a loss of any kind arising from or connected with this rome F Swan Commissions NC1524. N-I Inspector's n ture National Board, State, Province and Endorsements C /Date 222 Page 2 of 2 Revision 7

(C FORM NIS-2 OWNER'S RLRT FOR REPAIRS OR REPLACEMENTS As Required By The Previsions Of The ASME Code Section XI C.-.

1. Owner Address: Duke Power ComoanY Ia. Date March 21. 2005

-.- I 526 S. Church Street. Charlotte. NC 28201-1006' ' Sheet .1L of 1

2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferry Road. Huntorsvi.ii, NC 28078 2a. Unit: 01 02 i-3 0Shared(specifyUnits' '- _'_ )
3. Work Performed By: Duke Power ComDanv 3a. Work Order #:. 98709198 Address: 526 S. Church Street. Charlotte NC 28201-1006 Repair Orgzafon Job t Type Code Symbol Stamp: NLA Authorization No. N/A Expiration Date: N/A 3b. NSM or MM #: NJA
4. (a) Identification of System: CF - Feedwater' 4. (b) Class of System: B
5. (a) Appilcable Construction Code: ASME III 19Zj. Edition, Summer and Wlnter Addenda, N/

WA I Code Cases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Components Repaired or Heplaced and Replacement Com onents: -

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mg , Mfg Serial No. National Board No. Oer identificatioh, Year Built Repaired, Replaced, or ASME Code stamped

_ _ _ _ _ _ _ _ _ _ _ _ _ __ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _R ep iacem ent (ye or no)

A 0,Repaired, El No 2-MCR-CF-H402 . Duke Power 33795 N/A N/A N/A E Replaced,

- : -: _ __; .. O Replacement 0 Yes B  :. Repaired, El No 2-MCR-CF-H402 Duke Power 15705 N/A N/A N/A 0 Replaced,

_ ___ ___ ___ ___ . . -. Replacement O3 Yes C 0 Repaired, 0 No--.

ElReplaced,

. _.._._._.:_._._. .3 Replacement 0Yes' D 0 Repaired,% 0 No 0 Replaced,

. . . .. . . . . .. o Replacement O Yes E .. . Repaired, 0 No

-3 Replaced,

__________ .:.0 Replacement O3 Yes F . 0 Repaired, 0 No E. Replaced,-

._._  ;._ ._ -* . . . .0 Replacement 0 Yes Page 1 of 2 Revision 7

-I Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced snubber
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other U ExemptEl Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed -4Z/ 1t00/,;2 FL Grass Jr., QA Tech Specialist Date 1?-/Z/P OwneSgd Owner's Designee, tlue CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by aSB Cl have Inspc the components described in this Owners Report during the period 3 a to .ZZD; and state that to the best of my knowledge and belief, the Owner has performed ewaminations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injuor property damage or a loss of any kind arising from or connected with this Ispection. /

me F Swan Commissions NC1 5 N-I c ture National Board, State, Province and Endorsements Page 2 of 2 Revision 7

ai ; -1 x . fls iA!

C FORM NIS-2 OWNER'S Ri \RT FOR REPAIRS OR REPLACEMENTS As R-BT ,T FOf h AS

1. Owner Address: Duke Power Comoanv Ia. Date MajrchU72005

- 526 S. Church Street. Charlotte. NC 28201-1006 Sheet 1 of 1

2. Plant Address: McGuire Nuclear Station I' 12700 Hagers Ferr' Road. Huntersville. NC 28078 ?

2a. Unit: 01 02 03 OShared (specify Units '_)

3. Work Performed By: 'Duke Power Comranv 3a. Work Order #: " 98709200 Address: 526 S. Church Street. Charlotte NC 28201-1006 Repair Organiatin Job Type Code Symbol Stamp: NIA Authorization No. NQ Expiration Date: N/A 3b. NSM or MM #-_ ,_

N/A

. vf f

4. (a) Identification of System: SM- Main Steam 4. (b) Class of System: ' B
5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Wilnter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Components Repaired or Replaced and Replacement Cor onents:

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg M/g Serial No. National Board No. Oter Identification Year Bulit Repaired, Replaced, or ASME Code Stamped

._ ._ ._,_._..Replacement (ys or no)

A 03Repaired, El No 2-MCA-SM-H73 Duke Power' 15836 N/A N/A N/A 0 Replaced,

.3 . . Replacement 0Yes B .. Repaired, El No 2-MCA-SM-H73 Duke Power . 22424 N/A N/A N/A 0 Replaced,

___ ._._._._._._._._;_'._: _El Replacement 0Yes C 0.Repaired, 0 No,,

0;Replaced,

._3 : . ' '. . .. O Replacem'ent 0Yes' D 0l Repaired,. 0 No

.oReplaced,

___. .._ . . - . - . . . . ' O0 Replacement O Yes E .. 0 Repaired, 0 No

. Replaced,

. _3

. . . . . .. O Replacement O Yes F 0.Repaired, 0 No 03Replaced,-,

_ .~ -___________ 0.3 Replacement 0 Yes I .

Page 1 of 2 Revision 7

--- - - I Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced snubber
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 0 ExemptlZ Pressure psig Test Temp. OF Pressure _psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass Jr.. QA Tech Specialist Date Owner orOwner's Designee, Tite CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HBC; have ins ted he components described In this Owner's Report during the period to daa state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inju or property damage or a loss of any kind arising from or connected with this inspection.

rome F Swan Commissions NC1524. N-I Inspector's atre National Board, State, Province and Endorsements DateS 3//<?,

Page 2 of 2 Revision 7

FORM NIS-2 OWNER'S RLRT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl 0C

1. Owner Address: Duke Power Comoanv la. Date March 27. 2005 rn# S.Q Churc~h franf rhar`1r.NC 282P9An1:,1nnr6 -: Sheet 1 of I
2. Plant Address: McGuire Nuclear Siatlon 12700 Haaers Fenv Road. Huntersville. NC 28078 2a. Unit: 01 02 -03 03Shared (specify Units *_)
3. ~~~~

uW eo.Pew r e Boy n n fe

3. Work Performed By, Duke Power Company . 3a. Work Order # 98709201 Address: 526 S. Church Street. Charlotte NC 28201-1006 Repair organization Job fi I N/.

Type Code Symbol Stamp: N/A Authorization No. WA Expiration Date: N/A 4S . b 3b. NSM or MM # N/

WA

4. (a) Identification of System: FW - Refuelina Water .- 4. (b) Class of System: B
5. (a) Applicable Construction Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements: 1998.2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Components Repaired or Replaced and Replacement Corn onents:

= Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg - Mtg Serial No. National Board No. Other Identification Year Built Repaired, Replaced, or ASME Code Stamped

__ ._--_-___._._. _._-_,_._._._Replacem .. ent (yes or no)

A . . . 3 Repaired, i0 No 2-MCA-FW-5180 Duke Power 19765 N/A - N/A N/A 0 Replaced,

._ . . . . . . . a0 Replacement 0 Yes B 03Repaired, i0 No 2-MCA-FW-5180 Duke Power 20810 N/A N/A N/A 0 Replaced,

. __ ___ . - . . . . . ' i0 Replacement 0 Yes C . 0 Repaired, i0 No.

2-MCA-FW-5180 Duke Power 15872 - N/A N/A N/A El Replaced,

. ____ . _____ _ . : . _ '_ . _.__ 0 Replacement 0 Yes r D 0-Repaired, 0 No.

2-MCA-FW-5180; Duke Power ' . . 21829 . N/A N/A N/A. 0 Replaced,-:.

_ _ _ ;_______________ 0.-...l R eplacement 0 Yes E .3 0 Repaired, 0 No 03Replaced,

.. - ___ ___ . _;_._; _ ._. 0Replacement 0 Yes 0 Repaired, 0 No.

. 0.Replaced,'

__ . . . .. _._. 0 Replacement 0 Yes Page 1 of 2 Revision 7

_ _ lI-1 Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced snubber
8. Test Conducted:Hydrostatic U Pneumatic 0 Nom. Operating Press. EJ Other 0 ExemptO Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks (Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed i FL GrassJr.. QA Tech Snecialist Owner oKOwner's Designee, Title Date . - (

/,2 o CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by 1- 5 CT have ins ect d the components described in this Owner's Report during the period

_?/L'21 to 20 ;7and state that to the best of my knowledge and belief, the Owner hWs performed gaminations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described inthe Owner's Report. Furthermor , neither the Inspector nor his employer shall be liable in any manner for ny personal injury r property damage or a loss of any kind arising from or connected with this me F Swan Commissions NC1524. N-I reNational Board, State, Province and Endorsements Page 2 of 2 Revision 7

C. FORM NIS-2 OWNER'S RLi-T FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xi C_

1. Owner Address: Duke Power Comoanv la. Date March 16. 2005

-526 S. Church Street. Charlotte. NC 28201-1006 Sheet 1 of 1l

2. Plant Address: McGuire Nuclear Station - -

12700 Hajers Ferr, Road. Huntersville. NC 28078 2a. Unit: 01 M2 03 OShared (specify Units_ - _

3. Work Performed By~ Duke Power Comranv 3a. Work Order #: 98709207 Address: 526 S. Church Street. Charlotte NC 28201 -1006 Repair Organlzaon Job II Type Code Symbol Stamp: NIA Authorization No. NIA Expiration Date: N/A 3b. NSM or MM #: NiA
4. (a) Identification of System: SM - Main Steam 4. (b) Class of System: B
5. (a) Applicable Constrictilon Code: ASME III 1971 Edition, Summer and Winter Addenda, N/A - Code Cases -

(b) Applicable Edition of Section Xi Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)

6. Identification of Compon nts Repaired or Replaced and Replacement Com zonents:  : _

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Mfg Mu Selal No. National Board No. Other Idenificabon Year Built Repaired, Replaced, or ASME Code Stamped

.- , . . . .- . . ,. . . . Replacement (yes or no)

A . 0 Repaired, El No 2-MCA-SM-H102 Duke Power 15714 N/A N/A N/A El Replaced,

.__IO . . .; .- - . - _. ._ A -0 Replacement 0Yes B 03Repaired,, 0 No 2-MCA-SM-H102 Duke Power 16148 - N/A N/A N/A 0 Replaced,

.___El . . . . . .. .  ; . Replacement 0 Yes C 0.Repaired, 0 No 0 Replaced,

. . __. . ..3 .Replacement 0Yes -

D 0 Repaired, O No 0 Replaced,

___ -__ ._ _ . 0 Replacement

,- .. . 0Yes E 0 Repaired, 0 No 0 Replaced,

. . - v . _._._. . 0 Replacement 0Yes F ORepaired, O No 0 Replaced, 0

.__ ___3 . _ . . . 0Replacement _ Yes_._ -_.

i Page 1 of 2 Revision 7

il_-I Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced snubber
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 0 ExemptEs Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks (Applicable Manufacturer's Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Of~__

Signed , FL Grass Jr.. OA Tech Specialist Date 4/L4 2CLS.

Owner of Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HARB CT have lnspqcte the components described in this Owner's Report during the period to , E; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for ny personal injury or roperty damage or a loss of any kind arising from or connected with this nspect~ion e nr rome F Swan Commissions NC1524. N-I nspect S INational Board, State, Province and Endorsements Dat Page 2 of 2 Revision 7

C FORM NIS-2 OWNER'S RLhT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

(-I.

1. Owner Address: Duke Power Comranv la. Date March 20.2005 526 S. Church Street. Charlotte: NC 28201-1006 Sheet 1 of I
2. Plant Address: McGuire Nuclear Station

- 12700 Haoers Ferry Road. Hunters'vile. NC 28078 2a. Unit: 01 02 03 OShared (specify Units, _ _)

3. Work Performed By. Duke Power Company -;" . 3a. WorkOrder#: 98709210 Address:  ; 526 S.Church Street. Charlotte NC 28201-1006 ' Repair Organization Job i Type Code Symbol Stamp: WA Authorization No. -N/A Expiration Date: N/A 3b. NSM or MM #:_ N/A
4. (a) Identification of System: NV - Chemical and Volume Control 4. (b) Class of System: B
5. (a) ApplicableConstructionCode:ASMiEliV'19Zi Editlon, SummerandWinter Addenda, N/A Code Cases (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1998.2000 Addenda (1992 through 992 Addenda for Class MC and CC and thelr supports)

FS. Identifcation or tomponents Hepairea or Heplacea ana Replacement u-om onents:

Column 1 Column 2 Column 3 . Column 4, Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Other Identfication Year Built Repaired, Replaced, or ASME Code Stamped

,_ . _._.:_._._.Replacement (yes or no)

A . 0 Repaired, El No 2-MCA-NV-7020 Duke Power, . 14884 N/A N/A N/A El Replaced,

.___ . . . - - :. . .0 Replacement 0 Yes B 0 Repaired, El No 2-MCA-NV-7020 . Duke Power - 16592 N/A N/A N/A 0 Replaced,-

__- _ -_ ._ ._ ._._.._.-_._.._._._._i3 Replacem ent O Yes C Repaired, ONo 0 Replaced,'

.3 0 Replacement 0 Yes:

D 0 Repaired,. 0 No

. . - ;.. __.  : . . . . , . . .0 Replacement 0 Replaced,,

0 Yes F . 0 Repaired, 0 No 0 Replaced,

_ _3 . -;. - .. . . O Replacement 0 Yes

I Page 1 of 2 Revision 7

U -l Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced snubber
8. Test Conducted:Hydrostatic E Pneumatic E Nom. Operating Press. E Other 0 ExemptIl Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure -psig Test Temp. OF
9. Remarks (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A I_

Certificate of Authorization No. N/A Expiration Date N/A Signed-, U a FL Grass Jr.. QA Tech Specialist - . Date Owner or.&wners Designee, Ttle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT have inssecteO the components described In this Owners Report during the period e Q75to : and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury property damage or a loss of any kind arising from or connected with this jqinspection. //

Z vt'7rom e F Swan Commissions NC1524, N-I fns eco; re National Board, State, Province and Endorsements 6 Datzw/2U Page 2 of 2 Revision 7

bC FORM NIS-2 OWNER'S REiAT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI C(

1. Owner Address: Duke Power Comoanv 526 S. Church Street. Charlotte, NC 28201-1006 Sheet__L..of I
2. Plant Address: - McGuire Nuclear Station - , .

12700 Haaers Ferry Road, Hduntersville. NC 28078 2a. Unit: O1 02. 03 0Shared (specify Units )

3. Work Performed By Duke Power Comoanv 3a. Work Order # : 98709302105 Address: 526 S. Church Street. Charlotte NC 28201-1006 ' repairOrgarzea Job#

Type Code Symbol Stamp: N/A Authorization No. N/A Expiration Date: NAt 3b. NSM or MM #: MD200135

4. (a) Identification of System: KCO 4. (b) Class of System: B
5. (a) Applicable Construction Code: ASME Ill 19Zi Edition, Summer and Winter Addenda, i NA CodeCases (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Compon nts Repaired or Replaced and Replacement Corn onents: ' _-_-__

Column 1 Column 2 . Column 3' Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component - Name of Mfg - -Mfg Sedal No. National Board No. Oter Identification Year Built Repaired, Replaced, or ASME Code Starnped

- Replacement (Yes or no)

A . 0 Repaired,- 0 No Valve 2KC-479 KEROTEST DA7-25 6182 N/A 1975 0 Replaced,.-

_ _ . - El Replacement 0M Yes' B  ; 0 Repaired, 0 No

- - 03Replaced,

: . 0 Replacement O Yes C 0 Repaired, 0 No 03Replaced,:

. - 0 Replacement 0 Yes D 03Repaired, 0 No 0 Replaced,.

. . 0 Replacement 0 Yes E 03Repaired, 0 No 0 Replaced,

,__ ._ r__ . , . 0 Replacement 0 Yes F - .. - . 0 ORepaired, 0 No 0.Replaced,-

_3 . ' -- ' 0Replacement 0 Yes Page I of 2 Revision 7

lI-I Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced valve bonnet and Disc per MD200135
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. Ha Other 0 ExemptO Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed e ^ F.R. Sorrow. QA Tech Support Date 04/07, 2005 Owner or Owner's Designee, Ttie CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and PrQssure Vessel Inspectors and the State or Province of North Carolina and employed by HSI CT, have inspoct d the components described in this Owner's Report during the period to 4ea ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for Any personal injury r property damage or a loss of any kind arising from or connected with this

/ispection. f lerome F Swan Commissions NC1524, N-I Inspector National Board, State, Province and Endorsements 6 Date Page 2 of 2 Revision 7

FORM NIS-2 OWNER'S RL RT FOR REPAIRS OR REPLACEMENTS C; As Required By The Provisions Of The ASME Code Section XI

1. Owner Address: Duke Power Comoanv la. Date 03/30/2005 526 S. Church Street. Charlotte. NC 28201-1006 Sheet 1 of 1
2. Plant Address: McGuire Nuclear Station 12700 Haaers Ferrv Road. Huntersville, NC 28078 2a. Unit: 01 02 033 iShared (specify Units )
3. Work Performed By: Duke Power Comoany I 3a. Work Order #: 98716703104 Address: 526 S. Church Street. Charlotte NC 28201-1006  ;,  : -' Repair sOrganiza

.llnJob 0

I t . I Type Code Symbol Stamp: WA Authorization No. N1A Expiration Date: N/A 3b. NSM or MM #: N/A

4. (a) Identification of System: - NI 4. (b) Class of System: A

- -1 --

5. (a) Applicable Construction Code: ASME Ill 1971 Edition, Summer and Winter Addenda, N/A  : Code Cases (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1998. 2000 Adcdenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Compon nts Repaired or Replaced and Replacement Com 3onents: . .

Column 1 Column 2. Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Componren - Name of Mfg Mtg Serial No. National Board No. O tIdentification Year Built Repaired. Replaced, or ASME Code Stamped

_ _ _ _ _ _ _ _ _ _ _ __ ____ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _R epa ce men t (y r o A 0 Repaired, 0 No Valve 2NI-171 Kerotest EE9-23 7535 . N/A 1975 0 Replaced, 2__ ;_ _ ': .Replacement _ _ _ _ _ _ _ _ OYes B 0 Repaired,, 0 No 0 Replaced,

.____ -Replacement

,.____ . O Yes -

C 0 Repaired, 0 No

. . -. 0 Replaced,

.__ . . __ ._.._._. .0 Replacement 0 Yes D 0 Repaired, 0 No

- .: . 0 Replaced,

.__ -_ : -., . .. , .0 Replacement 0Yes E . 0.Repaired,: 0 No 03Replaced,

___ -__ .0 _.._..__. Replacement 0 Yes F .0 Repaired, 0 No 03Replaced,

. . . .. .O0 Replacement 0 Yes Page I of 2 Revision 7

-- uL Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Performed bonnet to body seal weld
8. Test Conducted:Hydrostatic 0 Pneumatic 0 Nom. Operating Press. 0 Other 0 ExemptrO1 Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp NIA Certificate of Authorization No. N/A Expiration Date N/A Signed d , F.R. Sorrow. OA Tech Support Date 03/30, 2005 Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Bailer and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT. have insp cted the components described in this Owner's Report during the period 3Iti/fI2 to 3-/.,/UA and state that to the best of my knowledge and belief, the Owner has performed exKmintions and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inju or property damage or a loss of any kind arising from or connected with this 7/ n c Inspctorss C tue erome F Swan Commissions NC1524. N-I National Board, State, Province and Endorsements I / Date S3~3 Page2of2 Revision 7

. C FORM NIS-2 OWNER'S RiZ RT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI C_

-1. Owner Address: Duke Power Comoanv Ia. Date March 27. 2005

. - 526 S. Church Street. Charotte. NC 28201-1006 Sheet 1 ofI
2. Plant Address: McGuire Nuclear Station 12700 Haoers Fenv' Road. Huntersville, NC 28078 2a. Unit: 01 EZ2 03 OShared (specify Units -
3. Work Performed By:- Duke Power Comoanv 3a; Work Order #: - 98718214 Address: 526 S. Church Street. Charlotte NC 28201-1006 RRepir OrgnIzation Job  :

Type Code Symbol Stamp: WA Authorization No. N/A Expiration Date: NIA 3b. NSM or MM #: N/A

4. (a) Identification of System: NI - Safetv Infection 4. (b) Class of System: B

, , I!

5. (a) Applicable Construction Code: ASME il 1971 Edition, Summer and Winter Addenda, N/A Code Cased (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements: 1998. 2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Components Repaired or Repiaced and Replacement Com onents:

Column 1 Column 2 Column 3 Column 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Mfg Mfg Serial No. National Board No. Oiler Identification Year Built Repaired. Replaced, or ASME Code Stamped

__ ____ ___ ___ __ ____ __ _ __ _ __ __ _Replacement (Wesor no)

A 0 Repaired, 0l No 2-MCR-NI-4528 Duke Power  ;- 5481 N/A - N/A N/A El Replaced, 0 Replacement 0 Yes B 0 Repaired, El No 2-MCR-NI-4528 Duke Power 97 61426 0/40 N/A N/A N/A 0 Replaced,

- 30Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,

. - 0 Replacement 0 Yes D 0 Repaired, 0 No

0 Replaced,

, - 0Replacement 0 Yes E 0 Repaired, 0 No

, O0 Replaced,

_: _ C0 Replacement 0Yes F  : 0 Repaired,- 0 No.-

0 Replaced,

-__ -__ -__ Replacement O__0 0Yes Page 1 of 2 Revision 7

u-A Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in itemsl through 6 on this report is included on each sheet, and (3)each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced snubber
8. Test Conducted:Hydrostatic Cl Pneumatic 0 Nom. Operating Press. 0 Other 0 ExemptEl Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks (Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass Jr. QA Tech Specialist Date or or er's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HS CT have inspected the components described in this Owner's Report during the period

.,/Z4*;2.s. to 7 CL; and state that to the best of my knowledge and belief, the Owner hs performed efaminations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for ny personal injury r property damage or a loss of any kind arising from or connected with this

{ispection. >

l/erome F Swan Commissions NC1524. N-1 lnspect National Board, State, Province and Endorsements

/Date  ? 9t t Page 2 of 2 Revision 7

C.c FORM NIS-2 OWNER'S RL.JRT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl

, C.

1. Owner Address: Duke Power Companv la. Date March29.2005

- 526 S. Church Street. Charlotte. NC 28201-1006 Sheet 1 of 1

2. Plant Address: McGuire Nuclear Staton -

12700 Hagers Ferry Road. Huntersville. NC 28078 2a. Unit: 01 02 03 OShared (specify Units "_'_ '-_ )

3. Work Performed By Duke Power Comoanv 3a. Work Order #: 98718216 Address: . 526 S. Church Street. Charlotte NC 28201-1006 -Repair r.gafon Job #

i I .

Type Code Symbol Stamp: NIA Authorization No. i A Expiration Date: NA 3b. NSM or MM #:_ WA

4. (a) Identification of System: NC - Reactor Coolant ...
4. (b) ' Class of System: A
5. (a) Applicable Construction Code: ASME lii 19_7 Edition, Summer and Winter Addenda, N/A Code Cases (b) Applicable Edition of Sectori Xl Utilized for Repairs or Replacements: 1998.2000 Addenda (1992 through 1992 Addenda for Class MC and CC and their supports)
6. Identification of Components Repaired or Replaced and Replacement Con 3onents:

CColumn 1 Column 2 - Column 3 Column 4 l Column 5 Col 6 Column 7 Column 8 Name of Componern Name of Mfg - Mfg Serial No. National Board No. Oter Identification Year Built Repaired, Replaced, or ASME Code Stamped

._ ._ ._._._.. Replacement (es or no)

A . 0 Repaired, i No 2-MCR-NC-4253' Duke Power 1842 N/A . N/A N/A i Replaced,

._ ._ ,_ '_.;'_' O Replacement OYes B 0 Repaired, i No 2-MCR-NC-4253 Duke Power 61257-45 N/A N/A N/A 0 Replaced,'

El Replacement 0 Yes C 0 Repaired, 0 No 0 Replaced,

. - O Replacement 0Yes D 0 Repaired, 0 No 03Replaced,-

-_. : - .;;0 Replacement 0 Yes E  : ' - ORepaired, 0 No 0 Replaced,

_____ -- '_.__ __. ._ :0 Replacement 0 Yes F - -' ' ' 0 Repaired, 0No 0 Replaced,

_ __ __ __ _ _ _ _ __ _ _ _ __ __ __ _ _ _ __ __ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _0 Re placem en t0 Ye Page 1 of 2 Revision 7

Form NIS-2 (Back)

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in items1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7. Description of Replaced snubber
8. Test Conducted:Hydrostatic El Pneumatic 0 Nom. Operating Press. 0 Other 0 Exempt0 Pressure psig Test Temp. OF Pressure psig Test Temp. OF Pressure psig Test Temp. OF
9. Remarks Test performed per task 9 of this work order (visual)

(Applicable Manufacturers Data Records to be attached)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed or1nersdFL Grass Jr., QA Tech Specialist Date

" vnror Ower's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HS13 CT have inspte the c mponents described in this Owner's Report during the period to 3 NF/and state that to the best of my knowledge and belief, the Owner h'as Oerformed e(aminations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in the Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for Any personal injiry or property damage or a loss of any kind arising from or connected with this 2 Pctn Jerome F Swan Commissions NC1524. N-l nspector} Si National Board, State, Province and Endorsements I /Datn Page 2 of 2 Revision 7

6.0 Pressure Testing This summary is a pressure test completion status for the first period of the third ten-year interval. Table 6-1 shows the pressure tests completed from refueling outage EOC-1 5 through refueling outage EOC-1 6. There was no through-wall leakage observed during these pressure tests.

Table 6-1 shows the number of Class 1 (Category B-P), Class 2 (Category C-H), and Risk Informed Segment (Category R-A) pressure tests completed for refueling outage EOC-1 6.

Table 6-1 Outage Specific Summary Examination Category Test Requirement Total Completed EOC16 B-P System Leakage Test (IWB-5221) 1 C-H System Leakage Test (IWC-5221) 2 R-A Risk Informed VT-2 for Socket Welds 66 Segments Table 6-2 shows a completion status of pressure tests conducted during the first period of the third ten-year interval.

Table 6-2 Period Specific Summary Total Total (%)

Examination Test Requirement Examinations Examinations Examinations Category Required For Credited For Complete For This Period This Period This Period B-P System Leakage Test 2 1 50%

(IWB-5221)

C-H System Leakage Test 34 2 5.88%

(IWC-5221)

R-A System Leakage Test (66 Segments 66 50%

Each Refueling Outage) 132 For Period EOC 16/ Outage 1 Page 1 of 7 McGuire Unit 2 Revision 0 Section 6 - Third Ten-Year Interval May 17, 2005

The Class 1 (Category B-P) pressure test zone is required each refueling outage. Table 6-3 shows a completion status of the Class 1 (Category B-P) pressure test zone conducted during x, refueling cycle EOC16.

Table 6-3 Detailed Class 1 Listing EOC16 Zone Completion Number Boundary Dwg Status EOC16 VT-2 Examination Date 2NC-001 L-A MC-ISIL-2553-01.00 Complete 4/8/2005 MC-ISIL-2553-02.00 Complete 4/8/2005 MC-ISIL-2553-02.01 Complete 4/8/2005 MC-ISIL-2554-01.00 Complete 4/8/2005 MC-ISIL-2554-01.01 Complete 4/8/2005 MC-ISIL-2554-01.021 Complete 4/8/2005 MC-ISIL-2561 -01.00 Complete 4/8/2005 MC-ISIL-2562-01.00 Complete 4/8/2005 MC-ISIL-2562-02.00 Complete 4/8/2005 MC-ISIL-2562-02.01 Complete 4/8/2005 MC-ISIL-2562-03.00 Complete 4/8/2005 MC-ISIL-2562-03.01 Complete 4/8/2005 Class 2 (Category C-H) pressure test zones are required once each inspection period. Table 6-4 shows a completion status of Class 2 (Category C-H) pressure tests required for the first period of the third ten-year interval.

Table 6-4 Detailed Class 2 Period Listing VT-2 Examination Zone Number Boundary Dwg Completion Status Date 1 2BB-040L-B MC-ISIL-2580-01.00 Not Yet Tested N/A 2 2BB-074L-B MC-ISIL-2572-03.00 Not Yet Tested N/A MC-ISIL-2580-01.00 Not Yet Tested N/A MC-ISIL-2584-01.00 Not Yet Tested N/A 3 2CA-040L-B MC-ISIL-2592-01.00 Not Yet Tested N/A 4 2CA-043L-B MC-ISIL-2584-01.00 Not Yet Tested N/A MC-ISIL-2591-01.01 Not Yet Tested N/A MC-ISIL-2592-01.00 Not Yet Tested N/A

_ MC-ISIL-2617-01.00 Not Yet Tested N/A 1 Recordable non through-wall leakage observed.

EOC 16 / Outage 1 Page 2 of 7 McGuire Unit 2 Revision 0 Section 6 - Third Ten-Year Interval May 17,2005

VT-2 Examination Zone Boundary Dwg Completion Status Date 5 2FW-007L-B MC-ISIL-2554-03.00 Not Yet Tested N/A MC-ISIL-2554-03.01 Not Yet Tested N/A MC-ISIL-2561-01.00 Not Yet Tested N/A MC-ISIL-2562-03.00 Not Yet Tested N/A MC-ISIL-2563-01.00 Not Yet Tested N/A MC-ISIL-2571-01.00 Not Yet Tested N/A 6 2ND-009L-B MC-ISIL-2554-01.02 Not Yet Tested N/A MC-ISIL-2561 -01.00 Partial 3/3/2005 MC-ISIL-2562-03.00 Not Yet Tested N/A MC-ISIL-2562-03.01 Not Yet Tested N/A MC-ISIL-2563-01.00 Not Yet Tested N/A MC-ISIL-2571 -01.00 Not Yet Tested N/A MC-ISIL-2572-01.00 Not Yet Tested N/A 7 2ND-01OL-B MC-ISIL-2561-01.00 Not Yet Tested N/A MC-ISIL-2562-03.01 Not Yet Tested N/A MC-ISIL-2563-01.00 Not Yet Tested N/A 8 2NI-012L-B MC-ISIL-2562-02.00 Completed in EOC16 4/8/2005 MC-ISIL-2572-01.01 Completed in EOC16 4/8/2005 9 2NI-013L-B MC-ISIL-2562-02.01 Completed in EOC16 4/8/2005 MC-ISIL-2572-01.01 Completed in EOC16 4/8/2005 10 2NI-014L-B MC-ISIL-2562-02.01 Not Yet Tested N/A MC-ISIL-2562-03.00 Not Yet Tested N/A 11 2NI-015L-B MC-ISIL-2562-03.00 Not Yet Tested N/A 12 2NI-016L-B MC-ISIL-2562-03.00 Not Yet Tested N/A 13 2NI-017L-B MC-ISIL-2562-03.00 Not Yet Tested N/A MC-ISIL-2562-03.01 Not Yet Tested N/A 14 2NI-018L-B MC-ISIL-2562-03.01 Partial 3/26/2005 15 2NI-060L-B MC-ISIL-2562-03.00 Not Yet Tested N/A 16 2N1-061 L-B MC-ISIL-2562-01.00 Partial 3/26/2005 17 2NI-062L-B MC-ISIL-2562-01.00 Not Yet Tested N/A 18 2NM-026L-B MC-ISIL-2572-01.01 Not Yet Tested N/A EOC 16 / Outage 1 Page 3 of 7 McGuire Unit 2 Revision 0 Section 6 - Third Ten-Year Interval May 17, 2005

VT-2 Examination Zone Boundary Dwg Completion Status Date 19 2NM-027L-B MC-ISIL-2572-03.00 Not Yet Tested N/A 20 2NS-019L-B MC-ISIL-2563-01.00 Not Yet Tested N/A 21 2NS-020L-B MC-ISIL-2563-01.00 Not Yet Tested N/A 22 2NV-003L-B MC-ISIL-2554-01.00 Not Yet Tested N/A MC-ISIL-2554-01.01 Partial 4/8/2005 MC-ISIL-2554-01.02 Partial 4/8/2005 MC-ISIL-2554-01.03 Partial 4/8/2005 23 2NV-004L-B MC-ISIL-1554-05.00 Not Yet Tested N/A MC-ISIL-2554-01.00 Not Yet Tested N/A MC-ISIL-2554-01.01 Partial 2/22/2005 MC-ISIL-2554-01.02 Not Yet Tested N/A MC-ISIL-2554-02.00 Not Yet Tested N/A MC-ISIL-2554-02.01 Not Yet Tested N/A MC-ISIL-2554-03.00 Partial 2/22/2005 MC-ISIL-2554-03.01 Partial 2/22/2005 MC-ISIL-2561-01.00 Not Yet Tested N/A MC-ISIL-2562-01.00 Partial 2/22/2005 MC-ISIL-2562-03.00 Partial 2/22/2005 24 2NV-005L-B MC-ISIL-2554-01.02 Partial 4/8/2005 25 2NV-006L-B MC-ISIL-2554-03.00 Partial 2/2/2005 26 2NV-008L-B MC-ISIL-2554-01.02 Not Yet Tested N/A 27 2NV-01 1L-B MC-ISIL-2554-03.01 Partial 2/2/2005 28 2RN-044L-B MC-ISIL-2574-04.00 Partial 4/8/2005 29 2RV-048L-B MC-ISIL-2604-03.00 Partial 3/4/2005 30 2SA-047L-B MC-ISIL-2593-01.02 Not Yet Tested N/A 31 2SM-040L-B MC-ISIL-2591 -01.01 Not Yet Tested N/A MC-ISIL-2593-01.00 Not Yet Tested N/A MC-ISIL-2593-01.03 Not Yet Tested N/A 32 2SM-045L-B MC-ISIL-2593-01.00 Not Yet Tested N/A MC-ISIL-2593-01.02 Not Yet Tested N/A MC-ISIL-2593-01.03 Not Yet Tested N/A EOC 16 /Outage 1 Page 4 of 7 McGuire Unit 2 Revision 0 Section 6 - Third Ten-Year Interval May 17,2005

VT-2 Examination Zone Boundary Dwg Completion Status Date 33 2SM-046L-B MC-ISIL-2593-01.00 Not Yet Tested N/A MC-ISIL-2593-01.03 Not Yet Tested N/A 34 2YA-063L-B MC-ISIL-2617-01.00 Not Yet Tested NIA Risk Informed Segments (Category R-A) that receive a pressure test are required each refueling outage. Table 6-5 shows a completion status of the Risk Informed Segment pressure test zones conducted during refueling cycle EOC16.

Table 6-5 Detailed Risk Informed Pressure Test Listing EOC16 Zone Segment Completion EOC16 VT-2 Number Boundary Dwg Number Status Examination Date 1 2NC-001 L-A MC-ISIL-2553-01.00 NC-18 Complete 4/8/2005 2 NC-19 Complete 4/8/2005

3. NC-20 Complete 4/8/2005 4 NC-21 Complete 4/8/2005 5 NC-23 Complete 4/8/2005 6 2 NC-86 Complete 4/8/2005 7 NC-89 Complete 4/8/2005 8 NC-90 Complete 4/8/2005 9 MC-ISIL-2553-02.00 NC-054 Complete 4/8/2005 10 NC-055 Complete 4/8/2005 11 NC-056 Complete 4/8/2005 12 MC-ISIL-2554-01.00 NV-033A Complete 4/8/2005 13 NV-033B Complete 4/8/2005 14 NV-034A Complete 4/8/2005 15 NV-034B Complete 4/8/2005 16 NV-037 Complete 4/8/2005 17 NV-038 Complete 4/8/2005 18 NV-041 A Complete 4/8/2005 19 NV-041 B Complete 4/8/2005 20 NV-042A Complete 4/8/2005 21 NV-042B Complete 4/8/2005 2 Part of this segment is also shown on drawing MC-ISIL-2553-02.01.

EOC 16 / Outage 1 Page 5 of 7 McGuire Unit 2 Revision 0 Section 6 - Third Ten-Year Interval May 17, 2005

Zone Segment I EOC16 EComleio EOC1 6 VT-2 Number Boundary Dwg Number Status Examination Date 22 2NC-001 L-A MC-ISIL-2554-01.01 NV-030A Complete 4/8/2005 23 NV-030B Complete 4/8/2005 24 NV-032A Complete 4/8/2005 25 NV-032B Complete 4/8/2005 26 NV-035 Complete 4/8/2005 27 NV-036 Complete 4/8/2005 28 NV-039A Complete 4/8/2005 29 NV-039B Complete 4/8/2005 30 NV-040A Complete 4/8/2005 31 NV-040B Complete 4/8/2005 32 MC-ISIL-2562-01.00 NI-068 Complete 4/8/2005 33 N1-069 Complete 4/8/2005 34 N1-070 Complete 1 4/8/2005 35 NI-071 Comolete 4/8/2005 36 2ND-009L-B MC-ISIL-2561 -01.00 ND-008C Complete 3/3/2005 37 ND-009C Complete 3/3/2005 38 2NI-061 L-B MC-ISIL-2562-01.00 NI-063B Complete 3/26/2005 39 2NV-003L-B MC-ISIL-2554-01.03 3 2NV026 Complete 4/8/2005 40 3 2NV027 Complete 4/8/2005 41 4 NV-028 Complete 4/8/2005 4

42 NV-029 Complete 4/8/2005 43 2NV-004L-B MC-ISIL-2554-01.01 NV-020AD Complete 2/22/2005 44 MC-ISIL-2554-03.00 5 NV-019AA Complete 2/22/2005 45 NV-019AB Complete 2/22/2005 46 NV-019AD Complete 2/22/2005 47 NV-019B Complete 2/22/2005 48 NV-019D Complete 2/22/2005 49 NV-020AA Complete 2/22/2005 50 NV-020AB Complete 2/22/2005 51 NV-020AE Complete 2/22/2005 52 NV-021 A Complete 2/22/2005 53 NV-021 B Complete 2t22/2005 MC-ISIL-2554-03.01 6 NV-002AB Complete 2/22/2005 54 55 NV-002D Complete 2/22/2005 56 NV-019C Complete 2/22/2005 57 NV-019E Complete 2/22/2005 58 2NV-005L-B MC-ISIL-2554-01.02 NV-080A Comolete 4/8/2005 I 59 NV-080B Comolete 4/8/2005 I 3 Part of this segment is also shown on drawing MC-ISIL-2554-01.01.

4 Part of this segment is also shown on drawing MC-ISIL-2554-01.00.

5 Part of this segment is also shown on drawing MC-ISIL-2554-03.01.

6 Part of this segment is also shown on drawing MC-ISIL-2554-03.00.

EOC 16 / Outage 1 Page 6 of 7 McGuire Unit 2 Revision 0 Section 6 - Third Ten-Year Interval May 17, 2005

EOC16 Zone Segment Completion EOC16 VT-2 Number Boundary Dwg Number Status Examination Date 60 2NV-005L-B MC-ISIL-2554-01.02 NV-084A Complete 4/8/2005 61 NV-084B Complete 4/8/2005 62 NV-084C Complete 4/8/2005 63 2NV-006L-B MC-ISIL-2554-03.00 NV-002C Complete 2/2/2005 64 NV-108A Complete 2/2/2005 65 NV-1 09 Complete 2/2/2005 MC-ISIL-2554-03.01 7 NV-011A Complete 2/2/2005 66 2NV-011L-B Section 6 Prepared By: Date:

Section Reviewed By: Date:

{e X:)7 /-/,'

94/t't(/ _f 5-7 Part of this segment is also part of zone 2NV-004L-B.

EOC 16 / Outage 1 Page 7 of 7 McGuire Unit 2 Revision 0 Section 6 - Third Ten-Year Interval May 17, 2005

ATTACHMENT No. 2 INSERVICE INSPECTION REPORT Duke Power Company McGuire Nuclear Station Unit 2 Sixteenth Refueling Outage Second Interval

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1. Owner:Duke Energy Corporation, 526 S. Church St., Charlotte, NC 28201-1006 (Name and Address of Owner)
2. Plant: McGuire Nuclear Station, 12700 Hager's Ferry Road Huntersville, N.C. 28078 (Name and Address of Plant)
3. Plant Unit:. 2 4. Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date: March 1,1984 6. National Board Number for Unit 84
7. Components Inspected:

Component or Manufacturer or Manufacturer or State or National Appurtenance Installer Installer Serial Province No. Board No.

No.

See Section 1.1 in the Attached Report Note: Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 81/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Total number of pages contained in this report 39.

I FORM NIS-1 (Back)

8. Examination Dates October 6,2003 to April 14,2005
9. Inspection Period Identification: Third Period
10. Inspection Interval Identification: Second Interval
11. Applicable Edition of Section XI 1989 Addenda None
12. Date / Revision of Inspection Plan: September 7, 1999/ Revision 3
13. Abstract of Examinations andTests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. See Sections 2.0. 3.0 and 6.0
14. Abstract of Results of Examinations and Tests. See Section 4.0 and 6.0
15. Abstract of Corrective Measures. See Subsection 4.3 We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code, Section Xl.

Certificate of Authorization No. (if applicable) N/A Expiration Date N/A Date 6/ - ZooT Signed Duke EnerMj Cor. By gt LJL Owner or CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission i ssud by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A > employed by

  • H$B CT of Connecticut have inspected the components described in this Owners Report during the period / 2 to Y// Y/ 2 o12f , and state that to the best of my knowledge and belief, the Owner has performed ekaminations and tests and taken corrective measures described in this Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, and corrective measures described in this Owner's Report. Furthermore, U

neither the Inspectr nor his employer shall be liable in any manner for any personal injury or property damage a loss of any kin arising from or connected with this inspection 14~-a . F Inspeefo,/ Signature Commissions ,A)kL ,_ , ,

/Sf / I "

N\1ational Board, State, Pr6vince, and Endorsements 615 Date 7// OS

  • The Hartford Steam Boiler Inspection & Insurance Company of Connecticut 200 Ashford Center North Suite 205 Atlanta, GA. 30338-4860 (800) 417-3721 www.hsbct.com

OWNER'S REPORT FOR INSERVICE INSPECTIONS MCGUIRE UNIT 2 2005 REFUELING OUTAGE 8 /EOC 16 (Second Interval)

Plant Location: McGuire Nuclear Station 12700 Hager's Ferry Road Huntersville, North Carolina 28078 NRC Docket No. 50-370 National Board No. 84 Commercial Service Date: March 1, 1984 Document Completion Date: 712-26o5-Owner: Duke Energy Corporation 526 South Church St.

Charlotte, N.C. 28201-1006 Revision 0 Prepared By: %Ik Date C.- I- 05 Reviewed By: co kakCoDate 6- %-05 Approved By: I I A d Date 6 /9 /C

DISTRIBUTION LIST

1. Duke Energy CorporationPlan Management Inservice Inspection (Original Copy)
2. McGuire Services Welding and Inspection (ISI Coordinator)

Control Desk

3. NRC Document of Connecticut (AIA)

Insurance Company Hartford Steam Boiler Inspection and

4. The do ANII at McGuire of North Carolina Department of Labor
5. State c/o J. M. Givens, Jr.

Assurance

6. Nuclear GO Nuclear c/o Bruce Nardoci K>

TABLE OF CONTENTS Section Title Revision 1.0 General Information 0 2.0 Second Ten-Year Interval Inspection Status 0 3.0 Final Inservice Inspection Plan 0 4.0 Results of Inspections Performed 0 5.0 Owner's Report for Repair / Replacement Activities 0 6.0 Pressure Testing 0

1.0 General Information This report describes the Inservice Inspection of Duke Energy Corporation's McGuire Nuclear Station Unit 2 during Outage 8 / EOC16. The Second Ten-Year Interval was extended by Request for Relief 03-004 asking for interval extension to perform the 10 year reactor vessel exam. ASME Section Xl, 1989 Edition with no Addenda, was the governing Code for selection and performance of the ISI examinations.

Included in this report are the inspection status for each examination category, the final inservice inspection plan, the inspection results for each item examined, and corrective action taken when reportable conditions were found. In addition, there is an Owner's Report for Repair / Replacement Section included for completed NIS-2 documentation of repairs and replacements.

1.1 Identification Numbers Manufacturer National Manufacturer or Installer State or Board Item or Installer Serial No. Province No. No.

Reactor Vessel Rotterdam 30664 NC-201819 =

Pressurizer Westinqhouse 1491 NC-201818 W10285 Steam Generator 2A BWI 7700-02 NC-302674 159 Steam Generator 2B BWI 7700-04 NC-302675 161 Steam Generator 2C BWI 7700-01 NC-302676 158 Steam Generator 2D BWI 7700-03 NC-302677 160 Centrifugal Charging Pump Pacific Pumps 2A - 48584 N/A 25 2B- 48585 28 Containment Spray Heat Delta Southern Co. 2A-35005-73-3 NC-234203 3396 Exchanger Joseph Oat & (2B) 2514 NC-201822 5765 Sons, Inc.

Excess Letdown Heat Westinghouse 1810 NC-234264 1555 Exchanger Letdown Heat Exchanger Joseph Oat & 2049-2B NC-201842 553 Sons, Inc.

Reciprocating Charging Union Pump Co. N7210318-604 N/A N/A Pump McGuire Unit 2 Page 1 of 5 Outage 8/EOC-16 Revision 0 Section 1 May 31, 2005

1.1 Identification Numbers (Continued)

Manufacturer National Manufacturer or Installer State or Board Item or Installer Serial No. Province No. No.

2A 5-114E841 G02 Reactor Coolant Pump Westinghouse 28 6-114E841 G02 N/A N/A 2C 7-114E841 G02 2D 8-114E841 G02 Reciprocating Charging Metal Bellows Company 74730-002 N/A 002 Pump Accumulator Reciprocating Charging Richmond Engineering N-2409.20 N/A 75220 Pump Suction Stabilizer Supply Co. _

Residual Heat Joseph Oat & Sons, Inc. 2A 2046-2C NC-169800 637 Removal Heat 2B 2046-2D NC-201823 638 Exchanger Safety Injection Pump Pacific Pumps 2A 49357 N/A 130 2B 49358 131 Regenerative Heat Joseph Oat & Sons, Inc. 2047-2B NC-201817 628 Exchanger 629

_____ _____ 630 Seal Water Heat Atlas Industrial 1767 NC 201827 1549 Exchanger Manufacturing Company Seal Water AMF Cuno 2A - 20 N/A 4364 Injection Filter 2B - 22 4365 Main Steam Supply to Duke Power Co. SA N/A 62 Auxiliary Equipment System Containment Air Release Duke Power Co. VQ N/A 56 and Addition System Main Steam System Duke Power Co. SM N/A 70 Main Steam Vent to Duke Power Co. SV N/A 67 Atmosphere System Reactor Coolant System Duke Power Co. NC N/A 82 McGuire Unit 2 Page 2 of 5 Outage 8/EOC-16 Revision 0 Section 1 May 31, 2005

1.1 Identification Numbers (Continued)

Manufacturer Manufacturer or Installer State or National Item or Installer Serial No. Province No. Board No.

Liquid Waste Recycle Duke Power Co. WL N/A 76 System Refueling Water Duke Power Co. FW N/A 54 System Auxiliary Feedwater Duke Power Co. CA N/A 73 System Residual Heat Duke Power Co. ND N/A 63 Removal System Nuclear Service Water Duke Power Co. RN N/A 60 System Chemical & Volume Duke Power Co. NV N/A 80 Control System Component Cooling Duke Power Co. KC N/A 78 System Main Feedwater Duke Power Co. CF N/A 61 System Containment Spray Duke Power Co. NS N/A 69 System Containment Duke Power Co. RV N/A 72 Ventilation Cooling Water System Safety Injection System Duke Power Co. NI N/A 83 Unit 2 Duke Power Co. N/A N/A 84 McGuire Unit 2 Page 3 of 5 Outage 8/EOC-16 Revision 0 Section 1 May 31, 2005

1.2 Personnel, Equipment and Material Certifications All personnel who performed or evaluated the results of inservice inspections during the time frame bracketed by the examination dates shown on the NIS-1 Form were certified in accordance with the requirements of the 1989 Edition of ASME Section Xi with no addenda including Appendix VII for ultrasonic inspections. In addition, ultrasonic examiners were qualified in accordance with ASME Section Xl, Appendix VIII, and 1995 Edition with the 1996 Addenda through the Performance Demonstration Initiative (PDI) for piping welds.

The appropriate certification records for each inspector, calibration records for inspection equipment, and records of materials used (i.e. NDE consumables) are on file at McGuire Nuclear Station or copies may be obtained by contacting the Duke Energy's Corporate Office in Charlotte, North Carolina.

The copies of the certification records for the Atlantic Group, Wesdyne Group and the Washington Group inspectors can be obtained by contacting the Duke Energy's Corporate Office in Charlotte, North Carolina.

1.3 Reference Documents The following reference documents apply to the inservice inspections performed during this report period. A copy may be obtained by contacting the ISI Plan Manager at Duke Energy's Corporate Office in Charlotte, North Carolina:

1. Code Case N-460 (Covers weld examination volume of 90% or greater)
2. Request for Relief 03-004 (Covers 10 year interval extension for reactor vessel.)

1.4 Augmented and Elective Examinations Augmented and elective examination information found within this Inservice Inspection Report is not required by the ASME Section Xi Code; therefore, it is exempt from ANII review, verification, and / or record certification.

McGuire Unit 2 Page 4 of 5 Outage 81E0-16 Revision 0 Section 1 May 31, 2005

1.5 Responsible Inspection AQency The Hartford Steam Boiler Inspection and Insurance Company of Connecticut are responsible for the third party inspections required by ASME Section Xl.

Authorized Nuclear Inservice Inspector(s)

Name: J.F. Swan Employer: The Hartford Steam Boiler Inspection & Insurance Company of Connecticut Business 200 Ashford Center North Address: Suite 205 Atlanta, GA 30338-4860 (800) 417-3721 www.hsbct.com McGuire Unit 2 Page 5 of 5 Outage 8/EOC-16 Revision 0 Section 1 May 31, 2005

2.0 Second Ten-Year Interval Inspection Status The completion status of inspections required by the 1989 ASME Code Section Xl, no Addenda is summarized in this section. The requirements are listed by the ASME Section Xl Examination Category as defined in Table IWB-2500-1 for Class 1 Inspections, Table IWC-2500-1 for Class 2 Inspections, and IWF-2500-1 (Code Case N-491 applies) for Class 1, 2 and 3 Component Supports.

Augmented Inspections are also included.

Class 1 Inspections Examination Description Inspections Inspections Percentage 'Deferral Category Required Completed Completed Allowed B-A Pressure Retaining Welds 15 15 *100% Yes in Reactor Vessel B-B Pressure Retaining Welds 5 5 100% No in Vessels Other than Reactor Vessels B-D Full Penetration Welds of 36 36 *100% Partial Nozzles in Vessels Inspection Program B B-E Pressure Retaining Partial REFERENCE SECTION 6.0 OF THIS REPORT Penetration Welds in Vessels B-F Pressure Retaining 38 38 *100% No Dissimilar Metal Welds B-G-1 Pressure Retaining Bolting . 237 237 **100% No Greater than 2" in Diameter B-G-2 Pressure Retaining Bolting 22 22 100% No 2" and Less in Diameter B-H Integral Attachments for 13 13 100% No Vessels B-J Pressure Retaining Welds 192 192 100% No in Piping B-K-1 Integral Attachments for N/A N/A N/A No Piping, Pumps and Valves

    • AIl bolting for previous generator's examined Outage 4, new generators B&C examined Outages 5&6. Code requirements met for Interval
  • Reference RFR 03-004 (10 Year Interval Extension for Reactor Vessel.)

McGuire Unit 2 Page 1 of 4 Outage 8/EOC-16 Revision 0 Section 2 May 31, 2005

Class 1 Inspections (Continued)

Examination Description Inspections Inspections Percentage 'Deferral Category Required Completed Completed Allowed B-L-1 Pressure Retaining Welds N/A N/A N/A Yes in Pump Casings B-L-2 Pump Casings 1 0 **00.00% Yes B-M-1 Pressure Retaining N/A N/A N/A Yes Welds in Valve Bodies B-M-2 Valve Body > 4 in. 6 3 **50.00% Yes Nominal Pipe Size B-N-1 Interior of Reactor Vessel 3 3 *100% No B-N-2 Integrally Welded Core 2 2 *100% Yes Support Structures and Interior Attachments to Reactor Vessels B-N-3 Removable Core Support 1 1 *100% Yes Structures B-O Pressure Retaining Welds 3 3 100% Yes in Control Rod Housings B-P All Pressure Retaining REFERENCE SECTION 6.0 OF THIS REPORT Components B-Q Steam Generator Tubing See Note below F-A Class 1 Component 49 49 100% No F01.01 0 Supports (Code Case N-491)

Note: Steam Generator Tubing Is examined and documented by the Steam Generator Maintenance Group of the Station Support Division as required by the Station Technical Specifications and Is not Included In this report.

'Deferral of Inspection to the end of the Interval as allowed by ASME Section Xl Table IWB 2500-1.

These examination categories are exempt from percentage requirements per IWB-2412 (a),

Inspection Program B.

  • Reference RFR 03-004 (10 Year Interval Extension for Reactor Vessel.)
    • Note: B-L-2 Category had no Pump Casings disassembled.
    • Note: B-M-2 Category had no additional valve groups disassembled.

McGuire Unit 2 Page 2 of 4 Outage 8/EOC-16 Revision 0 Section 2 May 31, 2005

Class 2 Inspections Examination Description Inspections Inspections Percentage Category Required Completed Completed C-A Pressure Retaining Welds 28 28 100%

in Pressure Vessels C-B Pressure Retaining Nozzle 10 10 100%

.__ _ Welds in Vessels .

C-C Integral Attachments for 7 7 100%

Vessels, Piping, Pumps, and Valves C-D Pressure Retaining Bolting N/A N/A N/A Greater Than 2" in Diameter C-F-1 Pressure Retaining Welds 251 251 100%

in Austenitic Stainless Steel or High Alloy Piping .

C-F-2 Pressure Retaining Welds 51 51 100%

in Carbon or Low Alloy Steel Piping . .

C-G Pressure Retaining Welds 6 6 100%

in Pumps and Valves C-H All Pressure Retaining REFERENCE SECTION 6.0 OF THIS Components REPORT F-A Class 2 Component 181 181 100%

Supports F01.020 (Code Case N-491) l McGuire Unit 2 Page 3 of 4 Outage 8/EOC-16 Revision 0 Section 2 May 31, 2005

Additional Class 1, 2 and 3 Component Support Inspections Examination Description Inspections Inspections Percentage Category Required Completed Completed F-A Supports other than Piping 37 37 100%

F01.040 Supports Class 1, 2 & 3 (Code Case N-491applies)

F-A Component Supports F01.050 Snubbers Class 1, 2 & 3 Inspections to be performed per Relief Request 97-005 Augmented Inspections Description Percentage Complete Reactor Coolant Pump Flywheels (Item No. Series G N o.)requirements for OUTAGE 8/EOC-1 6 Pipe Rupture Protection (Item No. Series G03.) No requirements for OUTAGE 8/EOC-1 6 McGuire Unit 2 Page 4 of 4 Outage 8/EOC-16 Revision 0 Section 2 May 31, 2005

3.0 Final Inservice Inspection Plan The final Ingervice Inspection Plan shown in this section lists all ASME Section Xl Class 1, Class 2, and Augmented inspections credited for this report period.

The information shown below is a field description for the reporting format included in this section of the report:

ITEM NUMBER = ASME Section Xi Tables IWB-2500-1 (Class 1), IWC-2500-1 (Class 2), IWF-2500-1 (Class 1 and Class 2 ), Augmented Requirements ID NUMBER = Unique Identification Number SYS = Component System Identification ISO / DWG NUMBERS = Location and / or Detail Drawings PROC = Examination Procedures INSP REQ = Examination Technique - Magnetic Particle, Dye Penetrant, etc.

MAT! SCH = General Description of Material DIA / THICK - Diameter / Thickness CAL BLOCKS = Calibration Block Number COMMENTS = General and / or Detail Description McGuire Unit 2 Page 1 of 1 Outage 8/EOC-16 Revision 0 Section 3 May 31, 2005

EOC 16

(

DUKE ENERGY CORPORATION CATEGORY B-A, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Reactor Vessel Inservice Inspection Database Management System Plan Report Shell Welds McGuire 2 Page 1 Inservice Inspection Plan for Interval 2 Outage 8 06/09/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Circumferential ****

B01.011.001 2RPV-W05 MCM 2201.01-0052 See Corn UT Cs 0.000 PDI-01 PC.04 to PC.05 UPPER SHELLL to MIDDLE SHELL Circumferential NC MCM2201.01-019 8.600 (Circumferential Weld)

Class A PC.04 UPPER SHELL to PROCEDURE PDI-ISI-254 PC.05 MIDDLE SHELL 801.011.002 2RPV-W04 MCM 2201.01-0052 See Corn UT CS 0.000 PDI-01 PC.4 to PC.3 Middle Shell to Lower Shell Circumferential NC MCM 2201.01-019 8.600 (Circumferential Weld)

Class A PC.04 MIDDLE SHELL to PROCEDURE PDI-ISI-254 P0.03 LOWER SHELL 801.011.003 2RPV-W03 MCM 2201.01-0052 See Corn UT CS 0.000 PDI-01 PC.03 to PC.02 Lower Shell to Lower Head Weld Circumferential NC MCM 2201.01-019 5.300 (Circumferential Weld) PROCEDURE Class A PC.03 Lower Shell to PDI-ISI-254 P0.02 Lower Head 801.011.004 2RPV-W06 MCM 2201.01-0052 See Corn UT CS 0.000 PDI-01 PC.05 to PC.06 Upper Shell to Nozzle Belt Circumferential NC MCM 2201.01-019 8.600 (Circumferential Weld)

Class A PC.05 Upper Shell to PROCEDURE PDI-ISI-254 PC.06 Nozzle Belt Total B01.011 Items: 4

EOC 16 DUKE ENERGY CORPORATION CATEGORY B-A, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Reactor Vessel InservIce Inspection Database Management System Plan Report WHead Welds McGuire 2 Page 2 Inservlce Inspection Plan for Interval 2 Outage 8 06/09/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUME 3ERS PROC INSP REO MAT/SCH DIAITHK CAL BLOCKS COMMENTS

        • Circumferential ****

B01.021.002 2RPV-WO1 MCM 2201.01 -01 See Com UT CS 0.000 PDI-01 PC.02 to PC.01 Lower Head to Bottom Head Weld Circumferential NC MCM 2201.01-019 5.300 (Circumferential Weld) PROCEDURE Class A PC.02 Lower Head to PDI ISI-254 PC.01 Bottom Head Total B01.021 Items: 1

        • Meridional ****

B01.022.001 2RPV.W02-01 MCM 2201.01-01 See Com UT CS 0.000 PDI-01 Meridional Weld on Lower Head at Approx. 210 Longitudinal NC MCM 2201.01-019 5.300 Deg. PROCEDURE PDI-ISI 254 Class A Lower Head to Lower Head B01.022.002 2RPV-W02-02 MCM 2201.01 -01 See Corn UT CS 0.000 PDI-01 Meridional Weld on Lower Head at Approx. 150 Longitudinal NC MCM 2201.01-019 5.300 Deg.

Class A Lower Head to PROCEDURE PDI-ISI-254 Lower Head B01.022.003 2RPV-W02-03 MCM 2201.01-01 See Com UT CS 0.000 PDI-01 Meridional Weld on Lower Head at Approx. 90 Deg.

Longitudinal NC MCM 2201.01 019 5.300 PROCEDURE PDI-ISI-254 Class A Lower Head to Lower Head B01.022.004 2RPV.W02-04 MCM 2201.01-01 See Corn UT CS 0.000 PDI-01 Meridional Weld on Lower Head at Approx. 30 Deg.

Longitudinal NC MCM 2201.01-019 5.300 PROCEDURE PDI-ISI-254 Class A Lower Head to Lower Head B01.022.005 2RPV-W02-05 MCM 2201.01.01 See Com UT CS 0.000 PDI-01 Meridional Weld on Lower Head at Approx. 330 Longitudinal NC MCM2201.01-019 5.300 Deg. PROCEDURE PDI-ISI-254 Class A Lower Head to Lower Head B01.022.006 2RPV-W02-06 MCM 2201.01-01 SeeCom UT CS 0.000 PDI-01 Merldlonal Weld on Lower Head at Approx. 270 Longitudinal NC MCM 2201.01-019 5.300 Deg. PROCEDURE PDI-ISI-254 Class A Lower Head to Lower Head Total B01.022 Items: 6

EOC 16 I DUKE ENERGY CORPORATION CATEGORY B-A. Pressure Retaininc Welds In INSERVICE INSPECTION PLAN MANAGEMENT Reactor Vessel Inservice Inspection Database Management System Plan Report Shell-to-Flanqe Weld McGuire 2 Page 3 Inservice Inspection Plan for Interval 2 Outage 8 06/09/2005 ITEM NUMBER IDNUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B01.030.002 2RPV-W07 MCM 2201.01-052 See Corn UT CS 0.000 PDI-01 PC.07 to PC.06 FLG. to Upper Shell (Noz. Belt)

Circumferential NC MCM2201.01 019 10.900 UT from Vessel ID (Circumferential Weld)

Class A PC.07 R V Flange to PROCEDURE PDI-ISI 254 PC.06 Upper Shell Total B101.030 Items: 1 Total B01 Items: 12

EOC 16 c

DUKE ENERGY CORPORATION CATEGORY B-D. Full Penetration Welds of INSERVICE INSPECTION PLAN MANAGEMENT Nozzels in Vessels Inservice Inspection Database Management System Plan Report lReactor Vessel McGuire 2 Page 4 Inservice Inspection Plan for Interval 2 Outage 8 0610912005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMEIERS PROC INSP REQ MAT/SCH DIMTHK CAL BLOCKS COMMENTS

        • Nozzle-to-Vessel Welds 803.090.001 2RPV-W1 1 MCM 2201.01-001 SeeCom UT CS 61.500 PDI-01 67 Deg. Inlet Nozzle to Shell Weld (UT from Vessel Circumferential NC MCM 2201.01 -01 9 10.900 ID)

Class A Inlet Nozzle to PROCEDURE PDI-ISI-254 Shell B03.090.001A 2RPV-W11 MOM 2201.01-001 SeeCom UT CS 61.500 PDI-01 67 Deg. Inlet Nozzle to Shell Weld (UT from Nozzle Circumferential NC MCM 2201.01-019 10.900 ID)

Class A Inlet Nozzle to PROCEDURE PDI-ISI-254-NZ Shell 803.090.002 2RPV-W12 MOM 2201.01-001 See Corn UT CS 61.500 PDI-01 113 Deg. Inlet Nozzle to Shell Weld (UT from Circumferential NC MOM 2201.01-019 10.900 Vessel ID)

Class A Inlet Nozzle to PROCEDURE PDI-ISI-254 Shell B03.090.002A 2RPV-W12 MOM 2201.01-001 See Corn UT CS 61.500 PDI-01 113 Deg. Inlet Nozzle to Shell Weld (UT from Circumferential NC MOM 2201.01-019 10.900 Nozzle ID)

Class A Inlet Nozzle to PROCEDURE PDI-ISI-254-NZ Shell B03.090.003 2RPV-W13 MOM 2201.01-001 See Corn UT CS 61.500 PDI-01 247 Deg. Inlet Nozzle to Shell Weld (UT from Circumferential NC MOM 2201.01-019 10.900 Vessel ID)

Class A Inlet Nozzle to PROCEDURE PDI-ISI-254 Shell B03.090.003A 2RPV-W13 MCM 2201.01-001 SeeCom UT CS 61.500 PDI-01 247 Deg. Inlet Nozzle to Shell Weld (UT from Circumferential NC MOM 2201.01-019 10.900 Nozzle ID)

Class A Inlet Nozzle to PROCEDURE PDI-ISI-254-NZ Shell 803.090.004 2RPV-W14 MOM 2201.01-001 See Corn UT CS 61.500 PDI-01 293 Deg. Inlet Nozzle to Shell Weld (UT from Circumferential NC MOM 2201.01-019 10.900 Vessel ID)

Class A Inlet Nozzle to PROCEDURE PDI-ISI-254 Shell B03.090.004A 2RPV-W14 MOM 2201.01-001 See Corn UT CS 61.500 PDI-01 293 Deg. Inlet Nozzle to Shell Weld (UT from Circumferential NC MCM2201.01-019 10.900 Nozzle ID)

Inlet Nozzle to PROCEDURE PDI-ISI-254-NZ Class A Shell

EOC 16

( (

DUKE ENERGY CORPORATION CATEGORY B-D, Full Penetration Welds of INSERVICE INSPECTION PLAN MANAGEMENT Nozzels in Vessels Inservice Inspection Database Management System Plan Report IReactor Vessel McGuire 2 Page 5 InservIce InspectIon Plan for Interval 2 Outage 8 06/09/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MATISCH DIA/THK CAL BLOCKS COMMENTS B03.090.005 2RPV-W15 MCM 2201.01-001 See Corn UT CS 52.900 PDI-01 22 Deg. Outlet Nozzle to Shell Weld (UT from Circumferential NC MCM 2201.01-019 10.900 Vessel ID)

Class A Outlet Nozzle to PROCEDURE PDI-ISI-254 Shell B03.090.005A 2RPV-W15 MCM 2201.01-001 See Corn UT CS 52.900 PDI-01 22 Deg. Outlet Nozzle to Shell Weld Circumferential NC MCM 2201.01-019 10.900 (UT from Nozzle ID)

Class A Outlet Nozzle to See Request for Relief 93-005 Shell PROCEDURE PDI-ISI-254-NZ B03.090.006 2RPV-W16 MCM 2201.01 -001 See Corn UT CS 52.900 PDI-01 158 Deg. Outlet Nozzle to Shell Weld Circumferential NC MCM2201.01-019 10.900 (UT from Vessel ID)

Class A Outlet Nozzle to PROCEDURE PDI-ISI-254 Shell B03.090.006A 2RPV-W16 MCM 2201.01-001 See Corn UT CS 52.900 PDI-01 158 Deg. Outlet Nozzle to Shell Weld Circumferential NC MCM 2201.01-019 10.900 (UT from Nozzle ID)

Class A Outlet Nozzle to See Request for Relief 93-005 Shell PROCEDURE PDI-ISI-254-NZ B03.090.007 2RPV-W17 MCM 2201.01-001 See Com UT CS 52.900 PDI-01 202 Deg. Outlet Nozzle to Shell Weld Circumferential NC MCM 2201.01-019 10.900 (UT from Vessel ID)

Class A Outlet Nozzle to PROCEDURE PDI-ISI-254 Shell B03.090.007A 2RPV-W17 MCM 2201.01-001 See Corn UT CS 52.900 PDI-01 202 Deg. Outlet Nozzle to Shell Weld Circumferential NC MCM 2201.01-019 10.900 (UT from Nozzle ID)

Class A Outlet Nozzle to See Request for Relief 93-005 Shell PROCEDURE PDI-ISI-254-NZ B03.090.008 2RPV-W18 MCM 2201.01-001 See Corn UT CS 52.900 PDI-01 338 Deg. Outlet Nozzle to Shell Weld Circumferential NC MCM 2201.01-019 10.900 (UT from Vessel ID)

Class A Outlet Nozzle to PROCEDURE PDI-ISI-254 Shell B03.090.008A 2RPV-W18 MCM 2201.01-001 See Corn UT CS 52.900 PDI-01 338 Deg. Outlet Nozzle to Shell Weld Circumferential NC MCM 2201.01-019 10.900 (UT from Nozzle ID)

Class A Outlet Nozzle to See Request for Relief 93-005 Shell PROCEDURE PDI-ISI-254-NZ Total B03.090 Items: 16

EOC 16 C ( (

DUKE ENERGY CORPORATION CATEGORY B-D, Full Penetration Welds of INSERVICE INSPECTION PLAN MANAGEMENT Nozzels In Vessels Inservice Inspection Database Management System Plan Report llReactor Vessel McGuire 2 Page 6 Inservice Inspection Plan for Interval 2 Outage 8 06/09/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Nozzle Inside Radius Section ****

B03.100.001 2RPV-W11 MCM 2201.01-001 See Com VT-1 CS 61.500 67 Deg. Inlet Nozzle to Shell Weld Circumferential NC MCM 2201.01-019 10.900 PROCEDURE WDI-STD-088 (EVT-1)

Class A Inlet Nozzle to Shell B03.100.002 2RPV-W12 MCM2201.01-001 See Corn VT-1 CS 61.500 113 Deg. Inlet Nozzle to Shell Weld Circumferential NC MCM 2201.01-019 10.900 PROCEDURE WDI STDO088 (EVT-1)

Class A Inlet Nozzle to Shell B03.100.003 2RPV-W13 MCM 2201.01-001 See Com VT-1 CS 61.500 247 Deg. Inlet Nozzle to Shell Weld Circumferential NC MCM 2201.01-019 10.900 PROCEDURE WDI-STD-088 (EVT.1)

Class A Inlet Nozzle to Shell B03.100.004 2RPV-W14 MCM2201.01-001 See Com VT-1 CS 61.500 293 Deg. Inlet Nozzle to Shell Weld Circumferential NC MCM 2201.01-019 10.900 PROCEDURE WDISTD-088 (EVT-1)

Class A Inlet Nozzle to Shell B03.100.005 2RPV-W15 MCM 2201.01-001 See Com VT-1 CS 52.900 22 Deg.Outlet Nozzle to Shell Weld Circumferential NC MCM2201.01-019 10.900 See Request for Relief 93-005 Class A Outlet Nozzle to PROCEDURE WDI STD-088 (EVT-1)

Shell 803.100.006 2RPV.W16 MCM 2201.01 -001 See Corn VT-1 CS 52.900 158 Deg.Outlet Nozzle to Shell Weld Circumferential NC MCM 2201.01-019 10.900 See Request for Relief 93-005 Class A Outlet Nozzle to PROCEDURE WDI.STD-088 (EVT-1)

Shell B03.100.007 2RPV-W17 MCM 2201.01.001 See Corn VT-1 CS 52.900 202 Deg.Outlet Nozzle to Shell Weld (Inside Radiu! Js)

Circumferential NC MCM2201.01-019 10.900 See Request for Relief 93-005 Class A Outlet Nozzle to PROCEDURE WDI-STD-088 (EVT-1)

Shell B03.100.008 2RPV-W18 MCM 2201.01 -001 See Corn VT-1 CS 52.900 338 Deg.Outlet Nozzle to Shell Weld (Inside Radius)

Circumferential NC MCM2201.01-019 10.900 See Request for Relief 93-005 Outlet Nozzle to PROCEDURE WDI-STD-088 (EVT-1)

Class A Shell Total B03.100 Items: 8 Total B03 Items: 24

EOC 16 C ( (

DUKE ENERGY CORPORATION CATEGORY B-F, Pressure Retaining Dissimilar INSERVICE INSPECTION PLAN MANAGEMENT Metal Welds Inservice Inspection Database Management System Plan Report Reactor Vessel McGuire 2 Page 7

  • InservIce Inspection Plan for Interval 2 Outag le8 06(09/2005 ITEM NUMBER IDNUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAALBLOCKS COMMENTS
        • NPS 4 or larger; Nozzle-to-Safe End Butt Welds ****

B05.010.001 2RPV-W11-SE MCM2201.01-18/3 See Corn UT SS-CS 27.500 See Corn RV INLET NOZZLE TO SAFE END 67 DEG.

Circumferential NC MCM 2201.01.0009 2.281 UT FROM NOZZLE SIDE Class A RV INLET NOZZLE to TO BE DONE WITH B05.130.004 Dissimilar SAFE END PROCEDURE PDI-ISI-254-SE CALIBRATION BLOCK NAVSHIPS TEST BLOCK LOOP A B05.010.001A 2RPV-W11-SE MCM 2201.01-18/3 See Corn UT Ss-CS 27.500 See Corn RV INLET NOZZLE TO SAFE END 67 DEG.

Circumferential NC MCM 2201.01-0009 2.281 UT FROM PIPE SIDE Class A RV INLET NOZLE to TO BE DONE WITH B05.130.004A Dissimilar SAFE END PROCEDURE PDI-ISI-254-SE CALIBRATION BLOCK NAVSHIPS TEST BLOCK LOOP A B05.010.002 2RPV-W12-SE MCM 2201.01-18/6 See Corn UT SS-CS 27.500 See Corn RV INLET NOZZLE TO SAFE END 113 DEG.

Circumferential NC MCM 2201.01-0009 2.281 UT FROM NOZZLE SIDE Class A RV INLET NOZZLE to TO BE DONE WITH B05.130.008 Dissimilar SAFE END PROCEDURE PDI-ISI-254-SE CALIBRATION BLOCK NAVSHIPS TEST BLOCK LOOP B B05.010.002A 2RPV-W12-SE MCM 2201.01-18/6 See Corn UT SS-CS 27.500 See Corn RV INLET NOZZLE TO SAFE END 113 DEG.

Circumferential NC MCM 2201.01 0009 2.281 UT FROM PIPE SIDE Class A RV INLET NOZZLE to TO BE DONE WITH B05.130.008A Dissimilar SAFE END PROCEDURE PDI-ISI-254-SE CALIBRATION BLOCK NAVSHIPS TEST BLOCK LOOP B B05.010.003 2RPV-W13-SE MCM 2201.01-18/9 See Corn UT Ss-CS 27.500 See Corn RV INLET NOZZLE TO SAFE END 247 DEG.

Circumferential NC MCM 2201.01-0009 2.281 UT FROM NOZZLE SIDE Class A RV INLET NOZZLE to TO BE DONE WITH B05.130.012 Dissimilar SAFE END PROCEDURE PDI-ISI-254-SE CALIBRATION BLOCK NAVSHIPS TEST BLOCK LOOP C R05.010.003A 2RPV-W13-SE MCM 2201.01-18/9 See Corn UT SS-CS 27.500 See Corn RV INLET NOZZLE TO SAFE END 247 DEG.

Circumferential NC MCM 2201.01-0009 2.281 UT FROM PIPE SIDE RV INLET NOZZLE to TO BE DONE WITH B05.130.012A Class A SAFE END PROCEDURE PDI-ISI-254-SE Dissimilar CALIBRATION BLOCK NAVSHIPS TEST BLOCK LOOP C

(s ( C EOC 16 DUKE ENERGY CORPORATION CATEGORY B-F. Pressure Retaining Dissimilar INSERVICE INSPECTION PLAN MANAGEMENT Metal Welds Inservice Inspection Database Management System Plan Report IReactor Vessel McGuire 2 Page 8 N Inservice Inspection Plan for Interval 2 Outage 8 a 06/09/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B05.010.004 2RPV-W14-SE MCM 2201.01-18/12 See Corn UT SS-CS 27.500 See Corn RV INLET NOZZLE TO SAFE END 293 DEG.

Circumferential NC MCM 2201.01-0009 2.281 UT FROM NOZZLE SIDE Class A RV INLET NOZZLE to TO BE DONE WITH B05.130.016 Dissimilar SAFE END PROCEDURE PDI-ISI-254-SE CALIBRATION BLOCK NAVSHIPS TEST BLOCK LOOP D B05.010.004A 2RPV-W14-SE MCM 2201.01-18/12 See Corn UT SS-CS 27.500 See Corn RV INLET NOZZLE TO SAFE END 293 DEG.

Circumferential NC MCM 2201.01-0009 2.281 UT FROM PIPE SIDE.

Class A RV INLET NOZZLE to TO BE DONE WITH B05.130.016A Dissimilar SAFE END PROCEDURE PDI-ISI-254-SE CALIBRATION BLOCK NAVSHIPS TEST BLOCK LOOP D B05.010.005 2RPV-W15-SE MCM 2201.01-18/1 See Corn UT SS-CS 29.000 See Corn RV OUTLET NOZZLE TO SAFE END 22 DEG. UT Circumferential NC MCM 2201.01-0010 2.312 FROM NOZZLE SIDE. REF. REQUEST FOR Class A RV OUTLET NOZZLE to RELIEF 93-005, B&W 1993 RPV REPORT.

Dissimilar SAFE END TO BE DONE WITH B05.130.001 PROCEDURE PDI-ISI-254-SE CALIBRATION BLOCK NAVSHIPS TEST BLOCK LOOP A B05.010.005A 2RPV-W15-SE MCM 2201.01-18/1 See Com UT SS-CS 29.000 See Corn RV OUTLET NOZZLE TO SAFE END 22 DEG. UT Circumferential NC MCM2201.01-0010 2.312 FROM PIPE SIDE. REF. REQUEST FOR RELIEF Class A RV OUTLET NOZZLE to 93-005, B&W 1993 RPV REPORT.

Dissimilar SAFE END TO BE DONE WITH B05.130.001A PROCEDURE PDI-ISI-254-SE CALIBRATION BLOCK NAVSHIPS TEST BLOCK LOOP A B05.010.006 2RPV-W16-SE MCM 2201.01-18/4 See Com UT SS-CS 29.000 See Corn RV OUTLET NOZZLE TO SAFE END 158 DEG. UT Circumferential NC MCM2201.01-0010 2.312 FROM NOZZLE SIDE. REF. REQUEST FOR Class A RV OUTLET NOZZLE to RELIEF 93-005, B&W 1993 RPV REPORT.

Dissimilar SAFE END TO BE DONE WITH B05.130.005 PROCEDURE PDI-ISI-254-SE CALIBRATION BLOCK NAVSHIPS TEST BLOCK LOOP B B05.010.006A 2RPV-W16-SE MCM 2201.01-18/4 See Corn UT SS-CS 29.000 See Corn RV OUTLET NOZZLE TO SAFE END 158 DEG. UT Circumferential NC MCM 2201.01-0010 2.312 FROM PIPE SIDE. REF. REQUEST FOR RELIEF Class A RV OUTLET NOZZLE to 93-005, B&W 1993 RPV REPORT.

SAFE END TO BE DONE WITH B05.130.005A Dissimilar PROCEDURE PDI-ISI-254-SE

EOC 16 C < (

DUKE ENERGY CORPORATION CATEGORY B-F, Pressure Retaining Dissimilar INSERVICE INSPECTION PLAN MANAGEMENT Metal Welds Inservice Inspection Database Management System Plan Report Reactor Vessel McGuire 2 Page 9 Inservice Inspection Plan for Interval 2 Outage 8 06/09/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS CALIBRATION BLOCK NAVSHIPS TEST BLOCK LOOP B B05.010.007 2RPV-W17-SE MCM 2201.01-18/7 See Com UT Ss-CS 29.000 See Corn RV OUTLET NOZZLE TO SAFE END 202 DEG. UT Circumferential NC MCM2201.01-0010 2.312 FROM NOZZLE SIDE. REF. REQUEST FOR Class A RV OUTLET NOZZLE to RELIEF 93-005, B&W 1993 RPV REPORT.

Dissimilar SAFE END TO BE DONE WITH B05.130.009.

PROCEDURE PDI-ISI-254-SE CALIBRATION BLOCK NAVSHIPS TEST BLOCK LOOP C B05.010.007A 2RPV-W17-SE MCM 2201.01-18/7 See Com UT SS-CS 29.000 See Com RV OUTLET NOZZLE TO SAFE END 202 DEG. UT Circumferential NC MCM2201.01-0010 2.312 FROM PIPE SIDE. REF. REQUEST FOR RELIEF Class A RV OUTLET NOZZLE to 93-005, B&W 1993 RPV REPORT.

Dissimilar SAFE END TO BE DONE WITH 805.130.009A PROCEDURE PDI-ISI-254-SE CALIBRATION BLOCK NAVSHIPS TEST BLOCK LOOP C B05.010.008 2RPV-W18-SE MCM 2201.01-19 See Corn UT SS-CS 29.000 See Corn RV OUTLET NOZZLE TO SAFE END 338 DEG. UT Circumferential NC MCM2201.01-0010 2.312 FROM NOZZLE SIDE. REF. REQUEST FOR Class A RV OUTLET NOZZLE to RELIEF 93-005, B&W 1993 RPV REPORT.

Dissimilar SAFE END TO BE DONE WITH B05.130.013 PROCEDURE PDI-ISI-254-SE CALIBRATION BLOCK NAVSHIPS TEST BLOCK LOOP D B05.010.008A 2RPV-W18-SE MCM 2201.01-19 See Com UT SS-CS 29.000 See Corn RV OUTLET NOZZLE TO SAFE END 338 DEG. UT Circumferential NC MCM2201.01-0010 2.312 FROM PIPE SIDE. REF. REQUEST FOR RELIEF Class A RV OUTLET NOZZLE to 93-005, B&W 1993 RPV REPORT.

Dsi Dissimilar SAFE END TO BE DONE WITH PROCEDURE B05.130.013A PDI-ISI-254-SE CALIBRATION BLOCK NAVSHIPS TEST BLOCK LOOP D Tt 1R0-tI.w I Utal nJ.

I.A U

S Ionr

.. Mo:.

tlI U

c ( C-EOC 16 DUKE ENERGY CORPORATION CATEGORY B-F. Pressure Retaininq Dissimilar INSERVICE INSPECTION PLAN MANAGEMENT Metal Welds Inservice Inspection Database Management System Plan Report McGuire 2 Page 10 Inservice Inspection Plan for Interval 2 Outag e8 06/09/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIANTHK CAL BLOCKS COMMENTS .

NPS 4 or Larger; Dissimilar Metal Butt Welds B05.130.001 2NC2F-1-1 See Corn UT Ss 29.000 See Com UT FROM NOZZLE/SAFE END SIDE:REF.RFR Circumferential NC MCM 2201.01-18/1 2.300 93.005, B&W 1993 RPV REPORT Class A MCM 2201.01-10 Pipe to TO BE DONE WITH 805.010.005 Dissimilar SAFE END PROCEDURE PDI.ISI-254-SE CALIBRATION BLOCK NAVSHIPS TEST BLOCK 22 DEG. LOOP A B05.130.001A 2NC2F-1-1 See Corn UT SS 29.000 See Corn UT FROM PIPE SIDE:REF.RFR 93-005, B&W 1993 Circumferential NC MCM 2201.01-18/1 2.300 RPV REPORT Class A MCM 2201 .01-10 Pipe to TO BE DONE WITH B05.010.005A Dissimilar SAFE END PROCEDURE PDI-ISI-254-SE CALIBRATION BLOCK NAVSHIPS TEST BLOCK 22 DEG. LOOP A B05.130.004 2NC2F-1-8 See Com UT SS 27.500 See Corn UT FROM NOZZLE/SAFE END SIDE Circumferential NC MCM 2201.01-18/3 2.281 TO BE DONE WITH B05.010.001 Class A MCM 2201.01-0009 Elbow to PROCEDURE PDIlISI-254-SE Dissimilar SAFE END CALIBRATION BLOCK NAVSHIPS TEST BLOCK 67 DEG. LOOP A B05.130.004A 2NC2F-1-8 See Com UT SS 27.500 See Corn UT FORM ELBOW SIDE Circumferential NC MCM 2201.01-18/3 2.281 TO BE DONE WITH B05.010.001A Class A MCM 2201.01-0009 Elbow to PROCEDURE PDI-ISI-254-SE CALIBRATION Dissimilar SAFE END BLOCK NAVSHIPS TEST BLOCK 67 DEG. LOOP A B05.130.005 2NC2F-2-1 See Coin UT SS 29.000 See Com UT FROM NOZZLE/SAFE END SIDE: REF. RFR Circumferential NC MCM 2201.01-18/4 2.300 93005, B&W 1993 RPV REPORT Class A MCM2201.01.10 Pipe to TO BE DONE WITH 805.010.006 Dissimilar SAFE END PROCEDURE PDI-ISI-254-SE CALIBRATION BLOCK NAVSHIPS TEST BLOCK 158 DEG. LOOP B B05.130.005A 2NC2F-2-1 See Com UT SS 29.000 See Corn UT FROM PIPE SIDE Circumferential NC MCM 2201.01-18/4 2.300 REF. RFR 93-005, B&W 1993 RPV REPORT MCM 2201.01-10 Pipe to TO BE DONE WITH B05.010.006A Class A SAFE END PROCEDURE PDI-ISI-254-SE Dissimilar CALIBRATION BLOCK NAVSHIPS TEST BLOCK 158 DEG. LOOP B

EOC 16 c ( C DUKE ENERGY CORPORATION CATEGORY B-F, Pressure Retaining Dissimilar INSERVICE INSPECTION PLAN MANAGEMENT Metal Welds Inservice Inspection Database Management System Plan Report E~niplnq McGuire 2 Page 11 Inservice Inspection Plan for Interval 2 Outage 8 06/09/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B05.130.008 2NC2F-2-8 See Corn UT SS 27.500 See Corn UT FROM NOZZLE/SAFE END SIDE Circumferential NC MCM 2201.01-18/6 2.300 TO BE DONE WITH B05.010.002 Class A MOM 2201 .01-09 Elbow to PROCEDURE PDI-ISI.254-SE Dissimilar SAFE END CALIBRATION BLOCK NAVSHIPS TEST BLOCK 113 DEG. LOOP B B05.130.008A 2NC2F-2-8 See Corn UT SS 27.500 See Corn UT FROM ELBOW SIDE Circumferential NC MCM 2201.01-18/6 2.300 TO BE DONE WITH B05.010.002A Class A MCM 2201.01-09 Elbow to PROCEDURE PDI-ISI254-SE Dissimilar SAFE END CALIBRATION BLOCK NAVSHIPS TEST BLOCK 113 DEG. LOOP B B05.130.009 2NC2F-3-1 See Corn UT SS 29.000 See Corn UT FROM NOZZLE/SAFE END SIDE: REF. RFR Circumferential NC MCM 2201.01-18/7 2.300 93-005, B&W 1993 RPV REPORT Class A MCM2201.01-10 Pipe to TO BE DONE WITH B05.010.007 Dissimilar SAFE END PROCEDURE PDI-lSl-254-SE CALIBRATION BLOCK NAVSHIPS TEST BLOCK 202 DEG. LOOP C B05.130.009A 2NC2F-3-1 See Corn UT SS 29.000 See Corn UT FROM PIPE SIDE Circumferential NC MCM 2201.01-18/7 2.300 REF. RFR 93-005, B&W 1993 RPV REPORT Class A MCM 2201.01-10 Pipe to TO BE DONE WITH B05.010.007A Dissimilar SAFE END PROCEDURE PDI-ISI.254-SE CALIBRATION BLOCK NAVSHIPS TEST BLOCK 202 DEG. LOOP C B05.130.012 2NC2F-3-8 See Corn UT SS 27.500 See Corn UT FROM NOZZLE/SAFE END SIDE Circumferential NC MCM 2201.01-18/9 2.281 TO BE DONE WITH B05.010.003 Class A MOM 2201.01-09 Elbow to PROCEDURE PD1-1S1-254-SE Dissimilar SAFE END CALIBRATION BLOCK NAVSHIPS TEST BLOCK 247 DEG. LOOP C B05.130.012A 2NC2F-3-8 See Com UT SS 27.500 See Corn UT FROM ELBOW SIDE Circumferential NC MCM 2201.01-18/9 2.281 TO BE DONE WITH B05.010.003A Class A MCM 2201.01-09 Elbow to PROCEDURE PDI ISI 254-SE Dissimilar SAFE END CALIBRATION BLOCK NAVSHIPS TEST BLOCK 247 DEG. LOOP C 805.130.013 2NC2F-4-1 See Corn UT Ss 29.000 See Corn UT FROM NOZZLE/SAFE END SIDE Circumferential NC MCM 2201.01-18/10 2.300 REF. RFR 93-005, B&W 1993 RPV REPORT Class A MCM 2201.01-10 Pipe to TO BE DONE WITH B05.010.008 SAFE END PROCEDURE PDI-ISI-254-SE Dissimilar CALIBRATION BLOCK NAVSHIPS TEST BLOCK

EOC 16 c C c DUKE ENERGY CORPORATION CATEGORY B-F, Pressure Retaining Dissimilar INSERVICE INSPECTION PLAN MANAGEMENT Metal Welds Inservice Inspection Database Management System Plan Report McGuire 2 Page 12 Inservice Inspection Plan for Interval 2 Outage 8 06/09/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS 338 DEG. LOOP D B05.130.013A 2NC2F-4-1 See Corn UT Ss 29.000 See Corn UT FROM PIPE SIDE Circumferential NC MCM 2201.01-18/10 2.300 REF. RFR 93-005, B&W 1993 RPV REPORT Class A MCM 2201.01-10 Pipe to TO BE DONE WITH B05.010.008A Dissimilar SAFE END PROCEDURE PDI-ISl.254-SE CALIBRATION BLOCK NAVSHIPS TEST BLOCK 338 DEG. LOOP D B05.130.016 2NC2F-4-8 See Corn UT SS 27.500 See Corn UT FROM NOZZLE/SAFE END SIDE Circumferential NC MOM 2201.01.18/12 2.300 TO BE DONE WITH B05.010.004 Class A MCM 2201 .01 09 Elbow to PROCEDURE PDIISI1254-SE Dissimilar SAFE END CALIBRATION BLOCK NAVSHIPS TEST BLOCK 293 DEG. LOOP D B05.130.016A 2NC2F-4-8 See Corn UT SS 27.500 See Corn UT FROM ELBOW SIDE Circumferential NC MCM 2201.01-18/12 2.300 TO BE DONE WITH B05.010.004A Class A MCM 2201.01-09 Elbow to PROCEDURE PDIlISI1254-SE CALIBRATION Dissimilar SAFE END BLOCK NAVSHIPS TEST BLOCK 293 DEG. LOOP D Total B05.130 Items: 16 32 Total B05 Items:

Total B05 Items: 32

EOC 16 c (

DUKE ENERGY CORPORATION CATEGORY B-N-1, Interior of Reactor Vessel INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Plan Report Reactor Vessel McGuire 2 Page 13 Inservice Inspection Plan for Interval 2 Outage 8 0610912005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MATISCH DIAITHK CAL BLOCKS COMMENTS

        • Vessel Interior ***

B13.010.001 2RPV-INTERIOR MCM 2201.01.21 See Corn VT-3 SS 0.000 AREA ABOVE AND BELOW CORE MADE NC 0.000 ACCESSIBLE DURING REFUELING Class A PROCEDURE WDI-STD-088 Total B13.010 Items: 1

EOC 16 C C C DUKE ENERGY CORPORATION CATEGORY B-N-2, Integral Welded Core Support INSERVICE INSPECTION PLAN MANAGEMENT Structures And Interior Attachment to RV Inservice Inspection Database Management System Plan Report Reactor Vessel (PWRR McGuire 2 Page 14 Inservice Inspection Plan for Interval 2 Outage 8 06109/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Interior Attachments Beyond Beitline Region ****

B13.060.001 2RPV-KEYWAY MCM 2201.01-21 See Com VT-3 SS 0.000 6-RADIAL KEYWAYS ATAPPROX. 60 DEGREE NC 0.000 INTERVALS (LOWER SHELL)

Class A PROCEDURE WDI'STD 088 B13.060.002 2RPV-INCORE MCM 2201.01 21 See Com VT-3 SS 0.000 58 INCORE INSTRUMENTATION NOZZLES NC 0.000 (BOTTOM HEAD)

Class A PROCEDURE WDI1STD-088 Total B13.060 Items: 2

EOC 16 c ( c DUKE ENERGY CORPORATION CATEGORY B-N-3, Removable Core Support INSERVICE INSPECTION PLAN MANAGEMENT Structures Inservice Inspection Database Management System Plan Report IReactor Vessel (PWR) McGuire 2 Page 15 Inservice Inspection Plan for Interval 2 Outage 8 06/09/2005 ITEM NUMBER ID NUMBER SYS ISO/DWG NIJMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS

        • Core Support Structure ****

B13.070.001 2RPV.CORE-SUP MCM 2201.01-21 See Com VT-3 SS 0.000 INSPECT WHEN STRUCTURE IS REMOVED NC 0.000 FROM REACTOR VESSEL Class A PROCEDURE WDI.STD-088 Total 813.070 Items: 1 Total B13 Items: 4

4.0 Results of Inspections Performed The results of each examination shown in the final Inservice Inspection Plan (Section 3 of this report) are included in this section. The completion date and status for each examination are shown. All examinations revealing reportable indications and any corrective action required as a result are described in further detail in Subsections 4.1 and 4.2. Corrective measures performed and limited examinations are described in further detail in Subsections 4.3 and 4.4.

The information shown below is a field description for the reporting format included in this section of the report:

ITEM NUMBER = ASME Section Xl Tables IWB-2500-1 (Class 1), IWC-2500-1 (Class 2), IWF-2500-1 (Class 1 and Class 2),

Augmented Requirements ID NUMBER = Unique Identification Number SYSTEM = Component System Identification INSP DATE = Date of Examination INSP STATUS = CLR Clear REC Recordable REP Reportable INSP LIMITED = Indicates inspection was limited.

Coverage obtained is listed.

GEO REF = Y Yes (Geometric Reflector N No applies only to UT)

RFR (Relief Request) = Y Yes NNo COMMENTS = General and / or Detail Description McGuire Unit 2 Page 1 of 3 Outage 8/EOC-16 Revision 0 Section 4 May 31, 2005

4.1 Reportable Indications There were no reportable indications for the examinations associated with this report period.

4.2 Corrective Action Corrective action is action taken to resolve flaws and relevant conditions, including supplemental examinations, analytical evaluations, repair / replacement activities, and corrective measures. There were no corrective actions for the examinations associated with this report period.

4.3 Corrective Measures Corrective measures are actions (such as maintenance) taken to resolve relevant conditions, but not including supplemental examinations, analytical evaluations, and repair / replacement activities. Any corrective measures performed for examinations associated with this report period will be shown on the examination data sheets which are on file at the Duke Energy Corporate Office in Charlotte, North Carolina.

4.4 Limited Examinations Limitations (i.e., 90% or less of the required examination coverage obtained) identified for examinations associated with this report period are shown below. A relief request will be submitted to seek NRC acceptance of the limited coverage this information will be on file at the Duke Energy Corporate Office in Charlotte, North Carolina.

Item Number Percentage Of Coverage B01.011.003 72.76%

B01.021.002 87.19%

B05.010.005 84.38%

B05,010.005A B05.010.007 80.24%

B05.010.007A B05.010.008 83.34%

B05.010.008A B05.130.001 84.38%

B05.130.001 A B05.130.009 80.24%

B05.130.009A McGuire Unit 2 Page 2 of 3 Outage 8IEOC-16 Revision 0 Section 4 May 31, 2005

Item Number Percentage Of Coverage B05.1 30.013 83.34%

B05.130.013A McGuire Unit 2 Page 3 of 3 Outage 8/EOC-16 Revision 0 Section 4 May 31, 2005

DUKE ENERGYC RPORATION QUALITY ASSURANCE TECHNICAL SERVICES

(

In-Service Inspection Database Management System Run D EOC 16 Page 1 McGuire 2 Inservice Inspection Listing Plant: McGuire 2 05/26/2005 Interval 2 Outage 8 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS B01.011.001 2RPV-W05 NC 03/18/2005 CLR --- N N B01 .011.002 2RPV-W04 NC 03/18/2005 CLR 90.91% N N B01.011.003 2RPV-W03 NC 03/19/2005 CLR 72.76% N Y B01.011.004 2RPV-W06 NC 03/21/2005 CLR .-- N N 801.021.002 2RPV-WO1 NC 03/20/2005 CLR 87.19% N Y B01.022.001 2RPV-W02-01 NC 03/19/2005 CLR ... N N B01.022.002 2RPV-W02-02 NC 03/19/2005 CLR --- N N 801.022.003 2RPV-W02-03 NC 03119/2005 CLR --- N N B01.022.004 2RPV-W02-04 NC 03/19/2005 CLR .-- N N B01.022.005 2RPV-W02-05 NC 03/19/2005 CLR --. N N 801.022.006 2RPV-W02-06 NC 03/19/2005 CLR -.. N N B01.030.002 2RPV-W07 NC 03/21/2005 CLR 99.21% N N B03.090.001 2RPV-W11 NC 03/21/2005 CLR 95.19% N N 803.090.001A 2RPV-W11 NC 03/20/2005 CLR 95.19% N N B03.090.002 2RPV-W12 NC 03/21/2005 CLR 95.19% N N B03.090.002A 2RPV-Wi2 NC 03/20/2005 CLR 95.19% N N B03.090.003 2RPV-W13 NC 03/21/2005 CLR 95.19% N N B03.090.003A 2RPV-Wi3 NC 03/20/2005 CLR 95.19% N N 803.090.004 2RPV-W14 NC 03/20/2005 CLR 95.19% N N 803.090.004A 2RPV-W14 NC 03/20/2005 CLR 95.19% N N 803.090.005 2RPV-W15 NC 03/20/2005 CLR 94.30% N N B03.090.005A 2RPV-W 15 NC 03/19/2005 CLR 94.30% N N B03.090.006 2RPV-W16 NC 03/19/2005 CLR 94.30% N N B03.090.006A 2RPV-W16 NC 03/19/2005 CLR 94.30% N N B03.090.007 2RPV-W17 NC 03/20/2005 CLR 94.30% N N B03.090.007A 2RPV-W17 NC 03/19/2005 CLR 94.30% N N 803.090.008 2RPV-Wi8 NC 03/20/2005 CLR 94.30% N N B03.090.008A 2RPV-W18 NC 03/20/2005 CLR 94.30% N N B03.100.001 2RPV-W 1 NC 03/16/2005 CLR -.- N N B03.100.002 2RPV-W12 NC 03/16/2005 CLR -.- N N B03.100.003 2RPV-W13 NC 03/16/2005 CLR -.. N N 803.100.004 2RPV-W14 NC 03/16/2005 CLR .-- N N B03.100.005 2RPV-W15 NC 03/16/2005 CLR --- N N B03.100.006 2RPV-Wi6 NC 03/16/2005 CLR --- N N B03.100.007 2RPV-Wl7 NC 03/16/2005 CLR .-- N N 803.100.008 2RPV-W18 NC 03/16/2005 CLR -.- N N

( DUKE ENERGIWE 1PORATION QUALITY ASSURANCE TECHNICAL SERVICES C In-Service Inspection Database Management System Run D EOC 16 Page 2 McGuire 2 Inservice Inspection Listing Plant: McGuire 2 05/26/2005 Interval 2 Outage 8 ITEM NUMBER ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS B05.010.001 2RPV-W11-SE NC 03/18/2005 CLR 95.36%

805.010.001A 2RPV-W11-SE NC 03/18/2005 CLR 95.36%

805.010.002 2RPV-W12-SE NC 03/19/2005 CLR 205.010.002A 2RPV-W12-SE NC 03/19/2005 CLR B05.010.003 2RPV-W 13-SE NC 03/18/2005 CLR 95.91%

B05.010.003A 2RPV-W13-SE NC 03/18/2005 CLR 95.91%

B05.010.004 2RPV-W14-SE NC 03/18/2005 CLR B05.010.004A 2RPV-W14-SE NC 03/18/2005 CLR B05.010.005 2RPV-Wi5-SE NC 03/18/2005 CLR 84.38%

B05.010.005A 2RPV-WI 5-SE NC 03/18/2005 CLR 84.38%

B05.010.006 2RPV-W16-SE NC 03/19/2005 CLR 90.34%

B05.010.006A 2RPV-W16-SE NC 03/19/2005 CLR 90.34%

B05.010.007 2RPV-W17-SE NC 03/18/2005 CLR ' 80.24%

B05.010.007A 2RPV-W17-SE NC 03/18/2005 CLR 80.24%

B05.010.008 2RPV-W18-SE NC 03/18/2005 CLR 83.34%

805.01 0.008A 2RPV-W 18-SE NC 03/18/2005 CLR 83.34%

B05.130.001 2NC2F-1-1 NC 03/18/2005 CLR 84.38%

B05.130.001A 2NC2F-1-1 NC 03/18/2005 CLR 84.38%

805.130.004 2NC2F-1-8 NC 03/18/2005 CLR 95.36%

B05.130.004A 2NC2F-1-8 NC 03/18/2005 CLR 95.36%

805.130.005 2NC2F-2-1 NC 03/19/2005 CLR 90.34%

B05.130.005A 2NC2F-2-1 NC 03/19/2005 CLR 90.34%

B05.130.008 2NC2F-2-8 NC 03/19/2005 CLR B05.130.008A 2NC2F-2-8 NC 03/19/2005 CLR B05.130.009 2NC2F-3-1 NC 03/18/2005 CLR 80.24%

805.130.009A 2NC2F-3-1 NC 03/18/2005 CLR 80.24%

B05.130.012 2NC2F-3-8 NC 03/18/2005 CLR 95.91%

B05.130.012A 2NC2F-3-8 NC 03/18/2005 CLR 95.91%

B05.130.013 2NC2F-4-1 NC 03/18/2005 CLR 83.34%

B05.130.013A 2NC2F-4-1 NC 03/18/2005 CLR 83.34%

B05.130.016 2NC2F-4-8 NC 03/18/2005 CLR 805.130.016A 2NC2F-4-8 NC 03/18/2005 CLR B13.010.001 2RPV-INTERIOR NC 03/20/2005 CLR 813.060.001 2RPV-KEYWAY NC 03/16/2005 CLR B13.060.002 2RPV-INCORE NC 03/22/2005 CLR B13.070.001 2RPV-CORE-SUP NC 03/16/2005 CLR

5.0 Owner's Report for Repair / Replacement Activities As required by the applicable code, records of Class 1 and Class 2 Repair and Replacement work is included on NIS-2 forms in this section.

No items were determined to have had work performed outside this report period.

Listed below is the information to address these issues.

I Work Order Number I Signoff Date/EOC l PIP Number l I None I N/A I N/A No NIS-2 forms are included in this section for work performed during this report period. Work performed during this time was reported in the Unit 2 EOC-16 (Outagel) Third Interval Inservice Inspection Report. The individual work request documents and manufacturers' data reports are on file at McGuire Nuclear Station.

5.1 Class 1 and 2 Preservice Examinations As required by the applicable code, Preservice Inspection (PSI) Examinations were performed on ISI Class 1 and 2 items during this report period. All Class 1 and 2 PSI examination data listed below is on file in the McGuire Nuclear Station QA Vault.

Work Order Identification Number Css Type of Inspection Class None N/A N/A McGuire Unit 2 Page 1 of 1 Outage 8/EOC-16 Revision 0 Section 5 May 31, 2005

6.0 Pressure Testin, This report is a compilation of pressure tests conducted to complete the requirements for the third period of the second 10-year interval. There were no relevant conditions observed during these pressure tests.

Table 6-1 shows the number of pressure tests completed to satisfy the third period requirements for the second 10-year interval.

Table 6-1 Examination Tet ReIe t Total Examinations Category es equiremenCredited for this report C-H System Inservice/Functional Test (IWC-5221) 9 C-H System Hydrostatic Test (IWC-5222) 27 Table 6-2 shows a listing of the (9) Class 2 Inservice/Functional pressure tests and the (27) Hydrostatic pressure tests completed to satisfy the third period requirements for the second 10-vear interval.

Table 6-2 DetailedListinq of Examinations 2 nd Interval VT-2 Inservice / Completion Examination Functional Item Number BoundaryDwg Status Date 1 C07.030.001 MCL-1554-5.0 Complete 02-22-2005 2 C07.030.002 MCL-2554-2.0 Complete 02-22-2005 3 C07.030.003 MCL-2554-3.0 Complete 02-21-2004 4 C07.030.004 MCL-2554-3.1 Complete 02-22-2005 5 C07.030.005 MCL-2561 -1.0 Complete 02-22-2005 6 C07.030.008 MCL-2562-2.1 Complete 02-13-2004 7 C07.030.009 MCL-2562-3.0 Complete 02-22-2005 8 C07.030.010 MCL-2562-3.1 Complete 12-09-2003 9 C07.030.039 MCL-2554-1.2 Complete 02-28-2005 EOC16 / Outage 8 Page 1 of 3 McGuire Unit 2 Revision 0 Section 6 - Second Ten-Year Interval April 14, 2005

Table 6-2 DetailedListing of Examinations 2nd Interval VT-2 Completion Examination Hydrostatic Item Number Boundary Dwg Status Date 1 C07.040.005 MCH-2554-1.0 Complete 02-22-2005 2 C07.040.006 MCH-2554-1.1 Complete 02-22-2005 3 C07.040.007 MCH-2554-1.2 Complete 02-22-2005 4 C07.040.008 MCH-2554-1.3 Complete 10-04-2003 5 C07.040.01 0 MCH-2554-3.0 Complete 02-22-2005 6 C07.040.011 MCH-2554-3.1 Complete 02-22-2005 7 C07.040.014 MCH-2561-1.0 Complete 02-22-2005 8 C07.040.015 MCH-2562-1.0 Complete 02-22-2005 9 C07.040.018 MCH-2562-3.0 Complete 02-22-2005 10 C07.040.019 MCH-2562-3.1 Complete 05-26-2004 11 C07.040.021 MCH-2563-1.0 Complete 02-22-2005 12 C07.040.024 MCH-2571 -1.0 Complete 02-22-2005 13 C07.040.025 MCH-2572-1.0 Complete 05-26-2004 14 C07.040.026 MCH-2572-1.1 Complete 03-03-2004 15 C07.040.028 MCH-2572-3.0 Complete 02-26-2004 16 C07.040.031 MCH-2573-3.1 Complete 02-09-2005 17 C07.040.033 MCH-2574-4.0 Complete 02-28-2005 18 C07.040.034 MCH-2580-1.0 Complete 10-04-2003 19 C07.040.035 MCH-2584-1.0 Complete 02-15-2005 20 C07.040.036 MCH-2591 -1.1 Complete 02-15-2005 21 C07.040.037 MCH-2593-1.0 Complete 02-16-2005 22 C07.040.038 MCH-2593-1.3 Complete 02-16-2005 23 C07.040.039 MCH-2592-1.0 Complete 02-15-2005 24 C07.040.040 MCH-2593-1.2 Complete 02-16-2005 25 C07.040.042 MCH-2617-1.0 Complete 02-15-2005 26 C07.040.044 MCH-2604-3.0 Complete 02-28-2005 27 C07.040.048 MCH-2554-2.1 Complete 02-22-2005 EOC16 I Outage 8 Page 2 of 3 McGuire Unit 2 Revision 0 Section 6 - Second Ten-Year Interval April 14, 2005 I

I

Table 6-3 shows the percentage of pressure tests completed to satisfy the third period req uirements for the second 10-year interval.

Table 6-3 Percentage of Examinations Comple ted Total Total (%o)

Examination Test Requirement Examinations Examinations Examinations Category RequiredFor CreditedFor Complete For This Period This Period This Period B-E System Hydrostatic 3 3 100%

Test (IWB-5222)

B-P System Leakage Test 1 1 100%

(IWB-5221)

B-P System Hydrostatic 1 1 100%

Test (IWB-5222)

C-H System 11 11 100%

Inservice/Functional Test (IWC-5221)

C-H System Hydrostatic 30 30 100%

Test (IWC-5222)

Section 6 Prepared By: Date:

l Ax I d/24o5-l U @ Setion QJviewed By: Date:

. u 4~ I 6__ _

D_

EOC16 / Outage 8 Page 3 of 3 McGuire Unit 2 Revision 0 Section 6 - Second Ten-Year Interval April 14,2005