{{#Wiki_filter:REGIS T. REPKO Vice President WEnergy McGuire Nuclear Station Duke Energy MGO VP / 12700 Hagers Ferry Rd. Huntersville, NC 28078 980-875-4111 980-875-4809 fax regis.repko@duke-energy.com January 12, 2012 U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555

Subject:

Duke Energy Carolinas, LLC (Duke) McGuire Nuclear Station, Unit 1 Docket Number 50-369 Inservice Inspection Report End of Cycle 21 Refueling Outage In accordance with ASME Section XI, attached is the In-service Inspection Report for the end of cycle 21 (EOC-21) refueling outage for McGuire Nuclear Station, Unit 1. This was the final outage of the Third Inspection Period for the Third Ten-Year Interval. Section 4.4 of the report lists the limited examination item numbers. Questions regarding this submittal should be directed to Kay L. Crane at (980) 875-4306. Regis T. Repko Attachment www. duke-energy. corn

U. S. Nuclear Regulatory Commission January 12, 2012 Page 2 xc (with attachment): V. M. McCree Administrator, Region II U.S. Nuclear Regulatory Commission Marquis One Tower 245 Peachtree Center, Ave., NE Suite 1200 Atlanta, GA 30303-1257 John Zeiler Senior Resident Inspector U.S. Nuclear Regulatory Commission McGuire Nuclear Station J.H. Thompson. (addressee only) NRC Project Manager U.S. Nuclear Regulatory Commission 11555 Rockville Pike Mail Stop 0-8 G9A Rockville MD 20852-2738

U. S. Nuclear Regulatory Commission January 12, 2012 Page 3 bxc (w/out attachments): J.M. Boughman *-7cg' R. Branch MCfo1fori K.L. Crane IM&01oi C,. M.A. Pyne t5CO5z j3 G.J. Underwood bxc (with attachments): McGuire Document Control File McGuire RGC File ELL-ECO50 OWNER'S REPORT FOR INSERVICE INSPECTIONS MCGUIRE UNIT 1 2011 REFUELING OUTAGE EOC 21 (OUTAGE 7) Location: McGuire Nuclear Station 12700 Hagers Ferry Road Huntersville, North Carolina 28078-9340 NRC Docket No. 50-369 National Board No. 44 Commercial Service Date: December 1, 1981 Document Completion Date: I- L Il. Owner: Duke Energy Carolinas 526 South Church St. Charlotte, N. C. 28201-1006 Revision 0 Prepared By: A t / Date / Z-,.- Reviewed By: Date /"_Z -d_- Approved By: Date / 2 -/ -?-

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1. Owner: Duke Enerqy Carolinas, 526 S. Church St.. Charlotte, NC 28201-1006 (Name and Address of Owner)
2. Plant: McGuire Nuclear Station, 12700 Haqers Ferry Road Huntersville, N.C. 28078-9340 (Name and Address of Plant)
3. Plant Unit: 1 4. Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date: December 1, 1981 6. National Board Number for Unit 44
7. Components Inspected:

Component or ManUfacturer or Manufacturer or State or National Appu rtenance Installer Installer Serial Province No. Board No. N o. See Section 1.1 in the Attached Report Note: Supplemental sheets in the form of lists, sketches, or drawings may be used, provided (1) size is 1 8 2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. Total number of pages contained in this report 396

FORM NIS-1 (Back)

8. Examination Dates April 19, 2010 to October 15, 2011
9. Inspection Period Identification: Third Period
10. Inspection Interval Identification: Third Interval
11. Applicable Edition of Section XI 1998 Addenda 2000
12. Date/Revision of Inspection Plan: June 20, 2006 / Revision 2
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. See Sections 2.0, 3.0, and 6.0
14. Abstract of Results of Examinations and Tests. See Section 4.0, and 6.0
15. Abstract of Corrective Measures. See Section 4.3 We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section XI, and c) corrective measures taken conform to the rules of the ASME Code, Section Xl.

Certificate of Authorization No. (if applicable) N/A Expiration Date N/A Date 20 / 2 -Signed Duke Energy Carolinas By Owner (J CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of North Carolina employed by Hartford Steam Boiler of Connecticut (HSBCT) have inspected the components described in this Owners' Report during the period April 19, 2010 to October 15, 2011, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in the Owners' Report in accordance with the Inspection Plan and as required by the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, test, and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a 'o s of any kind arising from or connected with this inspection SCommissions N.C. 1524 1,N nspector s Si gt 6re National Board, State, Province, and Endorsements ( Date L-10-- 2aO/P% HSBCT 200 Ashford Center North Suite 205 Atlanta, GA. 30338-4860 (800) 417-3721 www.hsbct.com

DISTRIBUTION LIST

1. Duke Energy Carolinas Nuclear Technical Services Division Section XI Inspection Program Section
2. Inspection Services (ISI Coordinator)
3. NRC Document Control Desk
4. HSBCT (AIA) c/o ANII at McGuire
5. State of North Carolina Department of Labor c/o J. M. Givens, Jr.

TABLE OF CONTENTS Section Title Revision 1.0 General Information 0 2.0 Third Ten-Year Interval Inspection Status 0 3.0 Final Inservice Inspection Plan 0 4.0 Results of Inspections Performed 0 5.0 Owner's Report for Repair / Replacement Activities 0 6.0 Pressure Testing 0 7.0 Containment Inservice Inspection (IWE) 0

1.0 GeneralInformation This report describes the Inservice Inspection of Duke Energy Corporation's McGuire Nuclear Station Unit 1 during Outage 7 / EOC 21. This is the last outage of the Third Inspection Period of the Third Ten-Year Interval. ASME Section XI, 1998 Edition through the 2000 Addenda was the governing Code for selection and performance of the ISI examinations. Included in this report are: the inspection status for each examination category, the final inservice inspection plan, the inspection results for each item examined, and corrective action(s) taken when reportable conditions were found. In addition, there is an Owner's Report for the Repair / Replacement Section included for complete NIS-2 documentation of repairs and replacements. 1.1 Identification Numbers Manufacturer Manufacturer or Installer State or National Item or Installer Serial No. Province Board No. No. Reactor Vessel Combustion CE67102 NC-1 78379 20766 Engineering Pressurizer Westinghouse 1471 NC-178395 68-123 Steam Generator 1A BWI 7701-04 NC-302668 157 Steam Generator 1B BWI 7693-01 NC-302669 146 Steam Generator 1C BWI 7701-03 NC-302670 155 Steam Generator 1D BWI 7701-02 NC-302671 154 Centrifugal Pacific Pumps 1A-48582 N/A 19 Charging Pump 1 B-48583 22 Containment Spray Heat Delta Southern Co. 1A-35005-73-1 NC-147799 3394 Exchanger 1B-35005-73-2 NC-147796 3395 Outage 7/EOC 21 Refueling Outage Report Page 1 of 6 McGuire Unit 1 Revision 0 Section 1 January 12, 2012

1.1 Identification Numbers Manufacturer Manufacturer or Installer State or National Item or Installer Serial No. Province Board No. No. Excess Letdown Heat Atlas Industrial 1809 NC-1 87817 1554 Exchanger Manufacturing Company Letdown Heat Exchanger Joseph Oat & Sons, Inc. 2049-2A NC-1 87881 552 Reciprocating Charging Union Pump Company N721031 B-603 N/A N/A Pump 1A 1-114E841G01 Reactor Coolant Pump Westinghouse 1B 2-114E841G01 N/A N/A 1C 3-114E841G01 1D 4-114E841G01 Reciprocating Charging Metal Bellows Company 74730-002 N/A 002 Pump Accumulator Reciprocating Charging Richmond Engineering N2409-10 N/A 75219 Pump Suction Stabilizer Supply Co. Residual Heat Joseph Oat & Sons, Inc. 1A-2046-2A NC-234202 635 Removal Heat 1B-2046-2A NC-234201 636 Exchanger Safety Injection Pump Pacific Pumps 1A-49355 N/A 80 1B-49356 81 Regenerative Heat Joseph Oat & Sons, Inc. 2047-2A NC-1 87897 595 Exchanger 596 597 Seal Water Heat Atlas Industrial 1766 NC 169797 1548 Exchanger Manufacturing Company Seal Water AMF Cuno 1A-13 N/A 3822 Injection Filter 11B-14 3823 Main Steam Supply to Duke Power Co. SA N/A 4 Auxiliary Equipment System Containment Air Release Duke Power Co. VQ N/A 12 and Addition System Main Steam System Duke Power Co. SM N/A 17 Outage 7/EOC 21 Refueling Outage Report Page 2 of 6 McGuire Unit 1 Revision 0 Section 1 January 12, 2012

1.1 Identification Numbers Manufacturer Manufacturer or Installer State or National Item or Installer Serial No. Province Board No. No. Main Steam Vent to Duke Power Co. SV N/A 18 Atmosphere System Reactor Coolant System Duke Power Co. NC N/A 28 Liquid Waste Recycle Duke Power Co. WL N/A 29 System Refueling Water System Duke Power Co. FW N/A 31 Auxiliary Feedwater Duke Power Co. CA N/A 32 System Residual Heat Removal Duke Power Co. ND N/A 35 System Nuclear Service Water Duke Power Co. RN N/A 36 System Chemical & Volume Duke Power Co. NV N/A 37 Control System Component Cooling Duke Power Co. KC N/A 38 System Main Feedwater System Duke Power Co. CF N/A 39 Containment Spray Duke Power Co. NS N/A 40 System Containment Ventilation Duke Power Co. RV N/A 41 Cooling Water System Safety Injection System Duke Power Co. NI N/A 42 Containment Purge Duke Power Co. VP N/A 6 Ventilation Outage 7/EOC 21 Refueling Outage Report Page 3 of 6 McGuire Unit 1 Revision 0 Section 1 January 12, 2012

1.1 Identification Numbers Manufacturer Manufacturer or Installer State or National Item or Installer Serial No. Province Board No. No. Safety Injection Delta Southern Co. 41617-72-1 NC-178396 3038 Accumulator Tank 1A Safety Injection Delta Southern Co. 41617-72-2 NC-178397 3039 Accumulator Tank 1B Safety Injection Delta Southern Co. 41617-72-3 NC-178398 3040 Accumulator Tank 1C Safety Injection Delta Southern Co. 41617-72-4 NC-178399 3041 Accumulator Tank 1D Unit 1 Duke Power Co. N/A N/A 44 1.2 Reference Documents The following reference documents apply to the inservice inspections performed during this report period. A copy may be obtained by contacting the ISI Plan Manager at Duke's Corporate Office in Charlotte, North Carolina:

1. Request for Relief (RFR) 01-004 (Class 1, 2 and 3 snubber examination under station technical specification)
2. RFR-01-GO-002 to use Code Case N-416-2 "Alternative Pressure Test Requirement for Welded Repairs, Fabrication Welds for Replacement Parts and Piping Subassemblies, or Installation of Replacement Items by Welding, Class 1, 2 and 3 Section XI, Division 1."
3. RFR 01-005 (Risk Informed Inservice Inspection Program Submittal)
4. RFR 01-008 (Risk Informed ISI Alternative to Use VT-2 Instead of Volumetric Examination of Socket Welds)
5. RFR 10-MN-002 Relief requested and approved to extend S/G primary manway stud exams to the first outage in the fourth interval. Summary Numbers Ml.B6.90.0001 through M1..B6.90.0008.

Outage 7/EOC 21 Refueling Outage Report Page 4 of 6 McGuire Unit 1 Revision 0 Section 1 January 12, 2012

Reference Documents continued

6. Code Case N-460 (Alternative Examination Coverage For Class 1 and Class 2 Welds, Section XI, Division 1.)
7. Code Case N-665 (Alternative Requirements for Beam Angle Measurements Using Refracted Longitudinal Wave Search Units)
8. Code Case N-685 (Lighting Requirements for Surface Examinations, Section Xl, Division 1.)
9. Code Case N-695 (Qualification Requirements for Dissimilar Metal Piping Welds, Section XI, Division 1.) Items are identified by the use of UT Procedure PDI-UT-1 0 and listed in the Plan Report in Section 3.0 of this report as dissimilar metal welds.
10. Code Case N-700 (Alternative Rules for Selection of Classes 1, 2 and 3 Vessel Welded Attachments for Examination Section Xl, Division 1)

(Categories B-K, C-C and D-A)

11. Code Case N-706 (Alternative Examination Requirements of Table IWB-2500-1 and Table IWC-2500-1 for PWR Stainless Steel Residual and Regenerative Heat Exchangers, Section XI, Division 1)
12. Code Case N-722 (Additional Examinations for Pressure Retaining Welds in Class 1 Components Fabricated with Alloy 600/82/182 Materials, Section XI, Division 1, 10CFR Part 50, Federal Register, final rule was issued September 10, 2008 mandates the use of this code case.) (Effective date is October 10, 2008)
13. Code Case N-729-1 (Alternative Examination Requirements for PWR Reactor Vessel Upper Heads with Nozzles Having Pressure Retaining Partial Penetration Welds Section ,Xl, Division 1. 10CFR Part 50, Federal Register, final rule was issued September 10, 2008 mandates the use of this code case.)
14. PIP M-07-2243 This PIP documented Summary Number M1.B1.21.0001 weld 1RPV6-446B as having less than 90% coverage and re scheduling weld for future examination.
15. PIP M-11-7710 This PIP documents dried boron on (3) M1.B15.90 welds 1RPV3-44F-SE, 1RPV3-445G-SE and 1 RPV3-445C-SE.
      .16. PIP M-11-7358 This PIP documents non service induced defects discovered on Summary Numbers M1.R1.11.2123 and M1.R1.16.0047 weld 1RCHP-IN.

Outage 7/EOC 21 Refueling Outage Report Page 5 of 6 McGuire Unit 1 Revision 0 Section 1 January 12, 2012

Reference Documents continued

17. PIP M-10-3538 This PIP was written to address stress corrosion cracking failure mechanism was not specified and only thermal fatigue mechanism was considered during RA exams.
18. PIP M-11-9036 This PIP was written to address limited welds and writing the RFR for limitations found during EOC-21.
19. PIP M-11-4662 This PIP will track alternative examination process identified in RR 10-MN-002 for S/G primary manway studs.
20. PIP M-1 1-6962 This PIP addresses water and boric acid deposits near the Unit 1 fuel transfer tube area.
21. PIP M-11-6842 This PIP addresses Unit 1 Ice Condenser temps being high, and placing ice bed at risk.
22. PIP M-1 1-6980 This PIP addresses water build up on the inside of equipment hatch.

Outage 7/EOC 21 Refueling Outage Report Page 6 of 6 McGuire Unit I Revision 0 Section 1 January 12, 2012

2.0 Third Ten-Year Interval Inspection Status The completion status of inspections required by the 1998 ASME Code Section XI through the 2000 Addenda is summarized in this section. The requirements are listed by the ASME Section Xl Examination Category as defined in Table IWB-2500-1 for Class 1 Inspections, Table IWC-2500-1 for Class 2 Inspections and IWF-2500-1 for Class 1, 2, and 3 Component Supports. Augmented, Elective, and Risk Informed inspections are also included. During the McGuire Third 10 Year Interval, piping welds will be examined under the Risk Informed Inservice Inspection Program developed in accordance with methodology contained in the Westinghouse Owner's Group (WOG) Topical Report, WCAP-14572, Revision 1-NP-A. Request for Relief 01-005 was submitted to the NRC seeking approval to incorporate the Risk Informed Program into the Third 10 Year Interval ISI Plan for McGuire Unit 1. The NRC approved use of this program per SER dated June 12, 2002. Previous code Examination Categories B-F, B-J, C-F-I, and C-F-2 will now be combined under the new Risk Informed Category R-A. Class I Inspections Examination Description Inspections Inspections Percentage 6Deferral Category Required Completed Completed Allowed B-A Pressure Retaining Welds 8 8 100% Yes in Reactor Vessel B-B Pressure Retaining Welds 5 5 100% No in Vessels Other than Reactor Vessel B-D Full Penetration Welded 24 24 100% Partial Nozzles in Vessels Inspection Program B B-F Pressure Retaining Reference Dissimilar Metal Welds in Risk Vessel Nozzles Informed Program R01. Items B-G-1 Pressure Retaining Bolting 243 *235 96.7% Yes Greater than 2" in Diameter

  • RR 10-MN-002 allows eight exams to be done in EOC-22.

Outage 7/EOC 21 Refueling Outage Report Page 1 of 5 McGuire Unit 1 Revision 0 Section 2 January 12, 2012

Class I Inspections Examination Description 6 Inspections Inspections Percentage Deferral Category Required Completed Completed Allowed B-G-2 Pressure Retaining 21 21 100% No Bolting 2" and Less in Diameter B-J Pressure Retaining Welds Reference in Piping Risk Informed Program R01. Items B-K Welded Attachments for 6 6 100% No Piping, Pumps and Valves B-L-1 Pressure Retaining Welds N/A N/A N/A Yes in Pump Casings B-L-2 Pump Casings 1*0 0.00% Yes B-M-1 Pressure Retaining N/A N/A N/A Yes Welds in Valve Bodies B-M-2 Valve Body > 4 in. **5 5 100% Yes Nominal Pipe Size B-N-1 Interior of Reactor Vessel 3 3 100% No B-N-2 Integrally Welded Core Support Structures and 2 2 100% Yes Interior Attachments to Reactor Vessels B-N-3 Removable Core Support I 1 100% Yes Structures B-0 Pressure Retaining Welds 3 3 100% Yes in Control Rod Housings

  • No pump casings disassembled this interval.
    • There were seven total valve groups. Only valves in five groups were disassembled and required examination this interval.

Outage 7/EOC 21 Refueling Outage Report Page 2 of 5 McGuire Unit 1 Revision 0 Section 2 January 12, 2012

Class I Inspections 6 Examination Description Inspections Inspections Percentage Deferral Category Required Completed Completed Allowed B-P All Pressure Retaining REFERENCE SECTION 6.0 OF THIS REPORT Components B-Q Steam Generator Tubing NA See General Requirements Section 3.1 F-A Class 1 Component 69 69 100% No F01.010 Supports 6 Deferral of inspection to the end of the interval as allowed by ASME Section Xl Tables IWB 2500-

1. These examination categories are exempt from percentage requirements per IWB-2412 (a),

Inspection Program B. Class 2 Inspections 6 Examination Description Inspections Inspections Percentage Deferral Category Required Completed Completed Allowed C-A Pressure Retaining Welds 28 28 100% No in Pressure Vessels C-B Pressure Retaining Nozzle 9 9 100% No Welds in Vessels C-C Welded Attachments for 32 32 100% No Vessels, Piping, Pumps and Valves C-D Pressure Retaining Bolting N/A N/A N/A N/A Greater Than 2" in Diameter C-F-1 Pressure Retaining Welds Reference in Austenitic Stainless Risk Informed Steel or High Alloy Piping Program R01. Items C-F-2 Pressure Retaining Welds Reference in Carbon or Low Alloy Risk Informed Steel Piping Program R01. Items II C-G Pressure Retaining Welds 8 8 100% No in Pumps and Valves C-H All Pressure Retaining REFERENCE SECTION 6.0 OF THIS REPORT Components F-A Class 2 Component 235 235 100% No F01.020 Supports Outage 7/EOC 21 Refueling Outage Report Page 3 of 5 McGuire Unit 1 Revision 0 Section 2 January 12, 2012

Additional Component Support Examinations Class 1, 2 & 3 Examination Description Inspections Inspections Percentage 6Deferral Category Required Completed Completed Allowed F-A Supports other than Piping 47 47 100% No F01.040 Supports Class 1, 2 & 3 1 1 1 F01.050 Component Supports, No Snubbers Class 1, 2 & 3 6 Deferral of inspection to the end of the interval as allowed by ASME Section Xl Tables IWB-2500-1 and IWC-2500-1.

  • Examinations to be performed per Request for Relief 01-004.

Risk Informed Inservice Inspection Program Class 1 and 2 Examination Description Inspections Inspections Percentage 6Deferral Category Required Completed Completed Allowed Piping Examinations R-A Class 1 and 2 Section 169 169 *100% No

  • Risk Informed percentages will be addressed per PIP M-10-3538.

Augmented / Elective Inspections Augmented and elective examination information found within this Inservice Inspection Report is not required by the ASME Section XI Code; therefore, it is exempt from ANII review, verification, and/or record certification. Summary Description Percentage Complete Number 100% of Outage 7 / EOC-21 M1..B15.80 Bare Metal Visual Inspection by VT-2 of BMI Nozzles per CC Requirements Met N-722 100% of Outage 7 / EOC-21 Ml.B135.90 Bare Metal Visual Inspection by VT-2 of RV hot leg nozzles Requirements Met per CC N-722 100% of Outage 7 / EOC-21 M11.B135.95 Bare Metal Visual Inspection by VT-2 of RV cold leg nozzles Requirements Met per CC N-722 100% of Outage 7 / EOC-21 M1.B4.10 Bare Metal Visual Inspection by VT-2 of RPV Head per CC Requirements Met N-729-1 No examinations required for M1.G2.1 RPV Closure Head Studs and Nuts per Nuclear Guide 1.65 Outage 7 / EOC-21 100% of Outage 7 / EOC-21 M1.G3.1 Pipe Rupture Protection Requirements Met No examinations required for M1.G4.1 Reactor Vessel Head to Pipe Welds Outage 7 / EOC-21 Outage 7/EOC 21 Refueling Outage Report Page 4 of 5 McGuire Unit 1 Revision 0 Section 2 January 12, 2012

No examinations required for M1.G5.1 Reactor Vessel Head Exams - VT-2 and UT Per NRC Order Outage 7 / EOC-21 EA-03-009 No examinations required for M1 .G5.2 Reactor Vessel Vent Line - UT per NRC Order EA-03-009, Outage 7 / EOC-21 PT per NRC Order EA-03-009, VT-2 every 4 refueling outages or 7years per NRC Order EA-03-009, and VT-2 every 3 refueling outages per MRP-1 39 No examinations required for M1 .G5.3 Bare Metal Inspections of the Reactor Vessel Primary Outage 7 / EOC-21 Nozzles per MRP-139 No examinations required for M1 .G6.1 Bare Metal Visual Inspection of the Pressurizer Welds per Outage 7 / EOC-21 MRP-139 M1 .G6.2 Bare Metal Visual Inspection of the Pressurizer Manway 100% of Outage 7 / EOC-21 Diaphram Seal Weld per NRC Bulletin 2004-0 1 Requirements Met Weld Overlay Section Xl Appendix Q Examination Description Inspections Inspections Percentage Deferral Category Required Completed Completed Allowed M1.Q1.1 Weld Overlay N/A N/A N/A No Outage 7/EOC 21 Refueling Outage Report Page 5 of 5 McGuire Unit 1 Revision 0 Section 2 January 12, 2012

3.0 FinalInservice Inspection Plan The final Inservice Inspection Plan shown in this section lists all ASME Section Xl Class 1, Class 2, Class 3, Augmented, and Risk Informed examinations credited for this report period. Outage 7/EOC 21 Refueling Outage Report Page 1 of 1 McGuire Unit 1 Revision 0 Section 3 January 12, 2012

DUKE ENERGY NUCLEAR TECHNICAL SERVICES ScheduleWorks Inservice Inspection DatabaseManagement System Plan Report McGuire 1, 3rd Interval, Outage 7 (EOC-21) This report includes all changes through addendum IMNS-087 Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThicklNPS Cal Blocks Componenet ID 2 Class / System Description Comments Category AUG M1.B15.80.0001 1-RPV-BMI-Nozzles Class 1 NC MP/0/A/7150/165 NDE-69 VT-2 Inconel Transition Weld to Stainless Steel Tube Bare Metal Visual Inspection by VT-2 qualified inspector of the BMI Nozzles per the requirements of Code Case N-722 (Item B15.80). The bare metal visual inspection shall include an inspection of the bottom head and Alloy 600 transition weld between the Alloy 600 tube and the stainless steel tube. This exam added per QA 513-J ER-MNS-09-01. This exam should be scheduled every other outage begining EOC-20. Reference Footnote 4 of Code Case N-722 for type of examination. Any questions concerning this exam should be directed to the Materials and NDE Services Group (Chris Cruz or Jody Shuping). These augmented examinations are being rescheduled per QA-513-J Form, Tracking Number ER-MNS-10-03, initiated by C.A. Cruz of the Materials and NDE Services Group. All bottom mounted instrument (BMI) nozzles and transition welds will be examined every refueling outage instead of every other outage outlined in ER-MNS-09-01. M1.B1 5.90.0001 1RPV3-445E-SE Class 1 NC MCFD 1553-01.00 NDE-68 VT-2 SS-Inconel 2.312 / 29.000 MCM 1201.01-0147 MCM 1201.01-0148 RV Primary Outlet Nozzle Weld and Buttering (Hot Leg) Nozzle to SE Examination Schedule begining 1EOC20 every refueling outage. Reactor Vessel Hot Leg Nozzles. Bare Metal Visual Inspection by VT-2 qualified inspector of the reactor vessel hot leg nozzles per the requirements of Code Case N-722. Per the requirements of 10 CFR 50.55a(g)(6)(ii)(E), all licensees of PWR's shall augment their ISI program by implementing ASME Code Case N-722 subject to the conditions specified in paragraph (g)(6)(ii)(E) 2 through 4. VT-2 Examination as specified in footnote 4 of Code Case N-722. Acceptance criteria is "no evidence of borated water leakage" Reference ER Tracking Number ER MNS- 09-09 . Any questions concerning this exam should be directed to the Materials and NDE Services Group (Chris Cruz or Jody Shuping). Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 1 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThicklNPS Cal Blocks Componenet ID 2 Class I System Description Comments Category AUG M1.B15.90.0002 1RPV3-445F-SE Class 1 NC MCFD 1553-01.00 NDE-68 VT-2 SS-Inconel 2.312 / 29.000 MCM 1201.01-0147 MCM 1201.01-0148 RV Primary Outlet Nozzle Weld and Buttering (Hot Leg) Nozzle to SE Examination Schedule begining 1EOC20 every refueling outage. Reactor Vessel Hot Leg Nozzles. Bare Metal Visual Inspection by VT-2 qualified inspector of the reactor vessel hot leg nozzles per the requirements of Code Case N-722. Per the requirements of 10 CFR 50.55a(g)(6)(ii)(E), all licensees of PWR's shall augment their ISI program by implementing ASME Code Case N-722 subject to the conditions specified in paragraph (g)(6)(ii)(E) 2 through 4. VT-2 Examination as specified in footnote 4 of Code Case N-722. Acceptance criteria is "no evidence of borated water leakage" Reference ER Tracking Number ER MNS- 09-09 . Any questions concerning this exam should be directed to the Materials and NDE Services Group (Chris Cruz or Jody Shuping). Ml.B1 5.90.0003 1RPV3-445G-SE Class 1 NC MCFD 1553-01.00 NDE-68 VT-2 SS-Inconel 2.312 /29.000 MCM 1201.01-0147 MCM 1201.01-0148 RV Primary Outlet Nozzle Weld and Buttering (Hot Leg) Nozzle to SE Examination Schedule begining 1EOC20 every refueling outage. Reactor Vessel Hot Leg Nozzles. Bare Metal Visual Inspection by VT-2 qualified inspector of the reactor vessel hot leg nozzles per the requirements of Code Case N-722. Per the requirements of 10 CFR 50.55a(g)(6)(ii)(E), all licensees of PWR's shall augment their ISI program by implementing ASME Code Case N-722 subject to the conditions specified in paragraph (g)(6)(ii)(E) 2 through 4. VT-2 Examination as specified in footnote 4 of Code Case N-722. Acceptance criteria is "no evidence of borated water leakage" Reference ER Tracking Number ER MNS- 09-09 . Any questions concerning this exam should be directed to the Materials and NDE Services Group (Chris Cruz or Jody Shuping). M1.B15.90.0004 1RPV3-445H-SE Class 1 NC MCFD 1553-01.00 NDE-68 VT-2 SS-Inconel 2.312 / 29.000 MCM 1201.01-0147 MCM 1201.01-0148 RV Primary Outlet Nozzle Weld and Buttering (Hot Leg) Nozzle to SE Examination Schedule begining 1EOC20 every refueling outage. Reactor Vessel Hot Leg Nozzles. Bare Metal Visual Inspection by VT-2 qualified inspector of the reactor vessel hot leg nozzles per the requirements of Code Case N-722. Per the requirements of 10 CFR 50.55a(g)(6)(ii)(E), all licensees of PWR's shall augment their ISI program by implementing ASME Code Case N-722 subject to the conditions specified in paragraph (g)(6)(ii)(E) 2 through 4. VT-2 Examination as specified in footnote 4 of Code Case N-722. Acceptance criteria is "no evidence of borated water leakage" Reference ER Tracking Number ER MNS- 09-09. Any questions concerning this exam should be directed to the Materials and NDE Services Group (Chris Cruz or Jody Shuping). Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 2 of 50

This report includes all changes through addendum lMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC.21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments Category AUG M1.B15.95.0003 1RPV3-445C-SE Class 1 NC MCFD 1553-01.00 NDE-68 VT-2 SS-Inconel 2.281 127.500 MCM 1201.01-0147 MCM 1201.01-0148 RV Primary Inlet Nozzle Weld and Buttering (Cold Leg) Nozzle to SE Examination Schedule begining 1EOC20. Reactor Vessel Cold Leg Nozzles to be inspected per the requirements of footnote 1 of 10 CFR 50.55a. These inspections shall begin in the interval in effect on January 1, 2009, and shall be prorated over the remaining periods and refueling outages in this interval. Bare Metal Visual Inspection by VT-2 qualified inspector of the reactor vessel cold leg nozzles per the requirements of Code Case N-722. Per the requirements of 10 CFR 50.55a(g)(6)(ii)(E), all licensees of PWR's shall augment their ISI program by implementing ASME Code Case N-722 subject to the conditions specified in paragraph (g)(6)(ii)(E) 2 through 4. VT-2 Examination as specified in footnote 4 of Code Case N-722. Acceptance criteria is "no evidence of borated water leakage" Reference ER Tracking Number ER MNS- 09-08, Any questions concerning this exam should be directed to the Materials and NDE Services Group (Chris Cruz or Jody Shuping). M1..B15.95.0004 1RPV3-445D-SE Class 1 NC MCFD 1553-01.00 NDE-68 VT-2 SS-Inconet 2.281 /27.500 MCM 1201.01-0147 MCM 1201.01-0148 RV Primary Inlet Nozzle Weld and Buttering (Cold Leg) Nozzle to SE Examination Schedule begining 1EOC20. Reactor Vessel Cold Leg Nozzles to be inspected per the requirements of footnote 1 of 10 CFR 50.55a, These inspections shall begin in the interval in effect on January 1, 2009, and shall be prorated over the remaining periods and refueling outages in this interval. Bare Metal Visual Inspection by VT-2 qualified inspector of the reactor vessel cold leg nozzles per the requirements of Code Case N-722. Per the requirements of 10 CFR 50.55a(g)(6)(ii)(E), all licensees of PWR's shall augment their ISI program by implementing ASME Code Case N-722 subject to the conditions specified in paragraph (g)(6)(ii)(E) 2 through 4. VT-2 Examination as specified in footnote 4 of Code Case N-722. Acceptance criteria is "no evidence of borated water leakage" Reference ER Tracking Number ER MNS- 09-08 . Any questions concerning this exam should be directed to the Materials and NDE Services Group (Chris Cruz or Jody Shuping). Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 3 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThicklNPS Cal Blocks Componenet ID 2 Class I System Description Comments Category AUG M1 .B4.10.0001 1RPV-Head Class 1 NC MCFD 1553-01.00 NDE-70 VT-2 MCM 1201.01-0186 001 As specified in ASME Code Case N-729-1, a direct visual examination of the bare metal surface of the entire outer surface of the head, including essentially 100% of the intersection of each nozzle with the head (J-groove). For coverage requirements see Figure 1 of Code Case N-729-1. For additional information reference QA-513J (ER-MNS-09-03). Acceptance criteria specified in ASME Code Case N-729-1 subject to the conditions in 10CFR 50.55a (g)(6)(ii)(D)(2) through (6). Relevant conditions for the purpose of the VE shall include areas of corrosion, boric acid deposits, discoloration, and other evidence of nozzle leakage. If EDY<8 and no flaws unacceptable for continued service have been detected, the reexamination frequency may be extended to every third refueling outage or 5 calendar years, whichever is less, provided an IWA-2212 VT-2 visual examination of the head is performed under the insulation through multiple access points in outages that the VE is not completed. Last Bare Metal Visual occurred during 1EOC18, so next full bare metal visual will be due in 1EOC21, provided EDY remains less than 8 and IWA-2212 VT-2 visuals are performed in every outage these VE's are not. EDY Calculation will continue to be updated and if EDY greater than or equal to 8 these VE's will be required every refueling outage, with no flexibility. Schedule Flexibility: Time between inspections may be shortened, but not lengthened. For additional information, contact Rachel Doss in the Materials and NDE Services Section, Nuclear Technical Services Division. This inspection replaces Augmented examinations M1.G5.1.0001 and Ml .G5.2.0001 required by NRC Order EA-03-009. Once licensee implements this requirement the First Revised NRC Order EA-03-009 no longer applies and is deemed to be withdrawn. Ml.G3.1.0004 1NC1F-107 Class 1 NC MCFI-1NC-47 NDE-35 PT SS 1.000 1 10.000 G03.001.002, G03.001.002/ Circumferential MC-ISIN3-1553-01.00 Elbow to Nozzle AUGMENTED EXAMINATION. REFERENCE DOCUMENT SRG-78-001 REV.2 (DISTRIBUTION CODE MADM-257). M1 .G3.1.0004 1NC1F-107 Class 1 NC MCFI-1NC-47 PDI-UT-2 UT SS 1.000 /10.000 PDI-UT-2-C G03.001.002, MC-ISIN3-1553-01.00 PDI-UT-2A-M G03.001.002/ 50209 Circumferential Elbow to Nozzle AUGMENTED EXAMINATION. REFERENCE DOCUMENT SRG-78-001 REV.2 (DISTRIBUTION CODE MADM-257). Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 4 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC.21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class / System Description Comments Category AUG Ml .G3.1.0005 1NC-72-1 Class 1 NC MCFI-1 NC-47 NDE-35 PT SS 1.000 / 10.000 G03.001.001, G03.001.001/ Circumferential MC-ISIN3-1553-01.00 Elbow To Pipe AUGMENTED EXAMINATION. REFERENCE DOCUMENT SRG-78-001 REV.2 (DISTRIBUTION CODE MADM-257). Ml.G3.1.0005 1NC-72-1 Class 1 NC MCFI-1NC-47 PDI-UT-2 UT SS 1.000/ 10.000 PDI-UT-2-C G03.001.001, MC-ISIN3-1553-01.00 PDI-UT-2A-M G03.001.001/ 50209 Circumferential Elbow To Pipe AUGMENTED EXAMINATION. REFERENCE DOCUMENT SRG-78-001 REV.2 (DISTRIBUTION CODE MADM-257). MIl.G3.1 .0006 INC-73-1 Class 1 NC MCFI-1NC-47 NDE-35 PT SS 1.000 / 10.000 G03.001.003, G03.001.003/ Circumferential MC-ISIN3-1553-01.00 Elbow To Pipe AUGMENTED EXAMINATION. REFERENCE DOCUMENT SRG-78-001 REV.2 (DISTRIBUTION CODE MADM-257). M1 .G3.1.0006 1NC-73-1 Class 1 NC MCFI-1NC-47 PDI-UT-2 UT SS 1.000 1 10.000 PDI-UT-2-C G03.001.003, MC-ISIN3-1553-01.00 PDI-UT-2A-M G03.001.003/ 50209 Circumferential Elbow To Pipe AUGMENTED EXAMINATION. REFERENCE DOCUMENT SRG-78-001 REV.2 (DISTRIBUTION CODE MADM-257). Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 5 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISO/DWG Numbers Procedure Insp Req Material Sched ThicklNPS Cal Blocks Componenet ID 2 Class I System Description Comments Category AUG M1.G6.2.0001 1PZR-MANWAY Class 1 NC MCM 1201.01-0170 001 NDE-68 VT-2 CS-Inconel 0.000 / 0.000 PZR Manway Insert (Gap Between Manway Cover and PZR) 1PZR-W1 1 Pressurizer Manway Diaphram Seal Weld. Bare Metal Visual Exam by VT-2 qualified inspector. Examine the gap between the Pressurizer Manway Cover and Manway for evidence of diaphram plate seal weld leakage. (For responsible individual, contact J.M. Shuping, Alloy 600 Enginerring Nuclear Technical Services). Reference NRC Bulletin 2004-01. To be done every Outage (EOC-18 through EOC-31) Category B-A M1 1B1.21.0001 1RPV6-446B Class I NC MCM 1201.01-204 PDI-UT-12 UT CS 7.000 10.000 50376 B101.021.00' MCM 1201.01-225 50470 Circumferential MCM 1201.01-224 Head Ring to Head Cap CLOSURE HEAD RING PC. 446-03 TO CLOSURE HEAD CAP PC.446-04. Examined EOC-18, 70.8% coverage. Rescheduled to EOC-19 to get additional coverage. Reference PIP M-07-02243. Rescheduled to 1EOC-20 to allow time for UT Inspector qualification, also shroud will not be removed during EOC-19. Reference PIP M-07-02243 for additional information concerning percent of weld coverage for this weld. Per code deferral is allowed until the end of interval, if no additional coverage is obtained RFR must be filed. Per station request on 01/12/2010 weld rescheduled from Outage 6 (1EOC-20) to Outage 7 (1EOC-21), 1EOC-21 will have much of the insulation removed for MRP-139 exams. W/O 1857060 will remove insulation from closure head. Drawing MCM 1201.01-0224 shows Reactor Head Thickness as 7 inch minimum at weld. Category B-B M1. B2.12.0002 1PZR-9 Class 1 NC MCM 1201.01-170 PDI-UT-6 UT CS 3.750 / N/A 50337 B02.012.00; Longitudinal MCM 1201.01-171 Head To Shell PRESSURIZER UPPER HEAD TO SHELL EXAMINED OUTAGE 3/EOC17 ADDITIONAL SAMPLE FOR ITEM NUMBER B02.011.001 REFERENCE PIP M-05-4894 Depending on personnel availability NDE-820, NDE-3611 and NDE-640 may be needed in lieu of PDI-UT-6. Drawing EDSK 379624B in Manual MCM 1201.01-0371 shows 2.500 minimum wall at the circumferential weld and 3.750 minimum wall for the shell which covers the lonqitudinal weld. Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 6 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThicklNPS Cal Blocks Componenet ID 2 Class I System Description Comments Category B-D M1 .13.100.0009 1RPV1-462A-IR Risk Segment NC-08 Class 1 NC MCM 1201.0 1-0247 NDE-71 VT-1 Inconel 0.625 / 6.250 MC-ISIN-155 53-01.00 Dissimilar MCM 1201.0 1-113 UHI Nozzle to Head UHI Auxiliary Head Nozzle located at 0 degrees on MCM 1201.01-0247( See Detail B). Examine inner radius as required per Figure IWB-2500-7(d). Reference PIP G-10-0134 CA# 9 and 17. Enhanced VT-1 Inspection is required in lieu of UT inspection. A Vendor that is qualified for remote automated Visual examinations (Enhanced VT-1) will have to be contracted to perform this inspection. M1.83.100.0010 1CRPV1 -462N-IR Risk Segment NC-08. Class 1 NC MCM 1201.0 11-0247 NDE-71 VT-1 Inconel 0.625 / 6.250 MC-ISIN-1553-01.00 Dissimilar MCM 1201.01-113 UHI Nozzle to Head UHI Auxiliary Head Nozzle located at 90 degrees on MCM 1201.01-0247( See Detail B). Examine inner radius as required per Figure IWB-2500-7(d). Reference PIP G-10-0134 CA# 9 and 17. Enhanced VT-1 Inspection is required in lieu of UT inspection. A Vendor that is qualified for remote automated Visual examinations (Enhanced VT-1) will have to be contracted to perform this inspection. M1.183.100.0011 1RPV1-462C-IR Risk Segment NC-08. Class 1 NC MCM 1201.01-0247 NDE-71 VT-1 Inconel 0.625 / 6.250 MC-ISIN-1553-01.00 Dissimilar MCM 1201.01-113 UHI Nozzle to Head UHI Auxiliary Head Nozzle located at 180 degrees on MCM 1201.01-0247( See Detail B). Examine inner radius as required per Figure IWB-2500-7(d). Reference PIP G-10-0134 CA# 9 and 17. Enhanced VT-1 Inspection is required in lieu of UT inspection. A Vendor that is qualified for remote automated Visual examinations (Enhanced VT-I) will have to be contracted to perform this inspection. Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 7 of 50

This report includes all changes through addendum lMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISO/DWG Numbers Procedure Insp Req Material Sched ThickINPS Cal Blocks Componenet ID 2 Class I System Description Comments Category B-D MI.B3.100.0012 1RPV1-462D-IR Risk Segment NC-08 Class 1 NC MCM 1201.01-0247 NDE-71 VT-1 Inconel 0.625 / 6.250 MC-ISIN-1553-01.00 Dissimilar MCM 1201.01-113 UHI Nozzle to Head UHI Auxiliary Head Nozzle located at 270 degrees on MCM 1201.01-0247( See Detail B). Examine inner radius as required per Figure IWB-2500-7(d). Reference PIP G-10-0134 CA# 9 and 17. Enhanced VT-1 Inspection is required in lieu of UT inspection. A Vendor that is qualified for remote automated Visual examinations (Enhanced VT-1) will have to be contracted to perform this inspection. Category B-G-1 M1.B6.1 10.0001 1SGC-MW-X2-Y1 Class 1 NC MCM 1201.01-0747 NDE-62 VT-1 CS 0.000 1 2.500 B06.1 10.00! MCM 1201.01-0684 STEAM GENERATOR IC PRIMARY INLET MANWAY NUTS. 20 NUTS. X2-Y1 QUADRANT. M1 .B6.110.0002 1SGC-MW-X2-Y2 Class 1 NC MCM 1201.01-0747 NDE-62 VT-1 CS 0.000 /2.500 B06.1 10.00 MCM 1201.01-0684 STEAM GENERATOR 1C PRIMARY OUTLET MANWAY NUTS. 20 NUTS. X2-Y2 QUADRANT. M1.B6.110.0007 1SGB-MW-X1-Y1 Class 1 NC MCM 1201.01-0747 NDE-62 VT-1 CS 0.000 / 2.500 B06.110.00: MCM 1201.01-0683 STEAM GENERATOR 1B PRIMARY INLET MANWAY NUTS. 20 NUTS. X1-Y1 QUADRANT. M1.B6.110.0008 1SGB-MW-Xl-Y2 Class 1 NC MCM 1201.01-0747 NDE-62 VT-1 CS 0.000 /2.500 B06.1 10.00' MCM 1201.01-0683 STEAM GENERATOR 16 PRIMARY OUTLET MANWAY NUTS. 20 NUTS. Xl-Y2 QUADRANT. Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 8 of 50

This report includes all changes through addendum lMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISO/DWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID2 Class I System Description Comments Category B-G-2 M1.B7.70.0011 1NI-175 Class 1 NI MC-ISIN3-1562-03.01 NDE-62 VT-1 SS 1.250 / N/A B07.070.0641 MCM-1205.36-00281001 GROUP 8.6" WESTINGHOUSE CHECKVALVE. INSPECT ONE OF THE FOLLOWING VALVES IN GROUP 8: 1NI-160, INI-175 and 1NI-176. Category B-K M1.B10.10.0002 1PZR-SKIRT Class 1 NC MCM 1201.01-170 NDE-25 MT CS 1.50010.000 B10.010.001, B10.010.0011 MCM 1201.01-0048 MCM 1201.01-140 Support Skirt To Head WELDED ATTACHMENT. PRESSURIZER SUPPORT SKIRT TO LOWER HEAD. Perform surface exam per Table IWB-2500-1 and Note 7 of Examination Category B-K. Reference PIP G-09-0921 CA#2. Implementation of Code Case N-700 requires this welded attachment to be examined. Reference PIP G-08-00499 ACA#2 and CA#5. Category C-A M1.C1.10.0001 1RHR-1A-3-4 Class 2 ND MCM 1201.06-22 VT-2 SS 0.750 /35.750 C01.010.05( Circumferential MC-ISIN3-1561-01.00 Nozzle belt To Flange RESIDUAL HEAT REMOVAL HEAT EXCHANGER IA. Residual Heat Removal Heat Exchanger 1A Nozzle Belt to Flange Weld. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Residual Heat Removal Heat Exchanger 1A is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and file Nos. MC-1212.04, MC-1223.04 and MC-1223.11 (Record Retention Code # 000252). Ifevidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected. This exam will be performed under the Pressure Test Program, reference McGuire third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISL-1561-01.00 and Plan Addendum M1-PT-023. A VT-2 visual exam will be performed for this weld. Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 9 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThickINPS Cal Blocks Componenet ID2 Class I System Description Comments Category C-A M1.C1.10.0005 1RHR-11B-3-4 Class 2 ND MCM 1201.06-22 VT-2 SS 0.750135.750 C01.010 Circumferential Nozzle Belt To Flange Residual Heat Removal Heat Exchanger 1B Nozzle Belt to Flange Weld. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Residual Heat Removal Heat Exchanger 1B is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and file Nos. MC-1212.04, MC-1223.04 and MC-1223.11 (Record Retention Code # 000252). Ifevidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected. This exam will be performed under the Pressure Test Program, reference McGuire third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISL-1561-01.00 and Plan Addendum M1-PT-023. A VT-2 visual exam will be performed for this weld. M1.C1.20.0001 5141-3-HD1 Class 2 NV MCM 1201.06-0015 VT-2 SS 1.075 / 10.920 C01.020.07, Circumferential MC-ISIN3-1554-01.02 Nozzle belt To Head REGENERATIVE HEAT EXCHANGER. (Shell 3) Regenerative Heat Exchanger (Shell 3) Nozzle Belt to Head Weld. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and file Nos. MC-1212.04, MC-1223.04 and MC-1223.11 (Record Retention Code # 000252). Ifevidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected. This exam will be performed under the Pressure Test Program, reference McGuire third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISL-1554-01.02 and Plan Addendum M1-PT-023. A VT-2 visual exam will be performed for this weld. Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 10 of 50

This report includes all changes through addendum 1MNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISOIDWG NIumbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments Category C-A M1.C1.20.0002 5141-3-HD2 Class 2 NV MCM 1201.06-0015 VT-2 SS 1.075 1 10.920 C01.020.07! Circumferential MC-ISIN3-1554-01.02 Shell To Head REGENERATIVE HEAT EXCHANGER. (Shell 3) Regenerative Heat Exchanger (Shell 3) Shell to Head Weld. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and file Nos. MC-1212.04, MC-1223.04 and MC-1223.11 (Record Retention Code # 000252). Ifevidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected. This exam will be performed under the Pressure Test Program, reference McGuire third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISL-1554-01.02 and Plan Addendum M1-PT-023. A VT-2 visual exam will be performed for this weld. M1.C1.20.0006 1RHR-11B-2-3 Class 2 ND MCM 1201.06-22 VT-2 SS 0.750 / 35.750 C01.020 Circumferential Nozzle belt To Head Residual Heat Removal Heat Exchanger 1B Nozzle Belt to Head Weld. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Residual Heat Removal Heat Exchanger 1B is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and file Nos. MC-1212.04, MC-1223.04 and MC-1223.11 (Record Retention Code # 000252). Ifevidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected. This exam will be performed under the Pressure Test Program, reference McGuire third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISL-1561-01.00 and Plan Addendum M1-PT-023. A VT-2 visual exam will be performed for this weld. Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 11 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISO/DWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments Category C-A M1.C1.20.0011 1RHR-1A-2-3 Class 2 ND MCM 1201.06-22 VT-2 SS 0.750/35.750 C01.020.03( Circumferential MC-ISIN3-1561-01.00 Nozzle belt To Head RESIDUAL HEAT REMOVAL HEAT EXCHANGER IA. Residual Heat Removal Heat Exchanger 1A Nozzle Belt to Head Weld. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Residual Heat Removal Heat Exchanger 1A is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and file Nos. MC-1212.04, MC-1223.04 and MC-1223.11 (Record Retention Code # 000252). If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected. This exam will be performed under the Pressure Test Program, reference McGuire third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISL-1561-01.00 and Plan Addendum M1-PT-023. A VT-2 visual exam will be performed for this weld. M1.C1.20.0012 5141-1-HD1 Class 2 NV MCM 1201.06-0015 VT-2 SS 1.075 110.920 C01.020.07( Circumferential MC-ISIN3-1554-01.02 Nozzle belt To Head REGENERATIVE HEAT EXCHANGER. (Shell 1) Regenerative Heat Exchanger (Shell 1) Nozzle Belt to Head Weld. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and file Nos. MC-1212.04, MC-1223.04 and MC-1223.11 (Record Retention Code # 000252). If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected. This exam will be performed under the Pressure Test Program, reference McGuire third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISL-1554-01.02 and Plan Addendum M1-PT-023. A VT-2 visual exam will be performed for this weld. Printed 01/12/12 GJUB302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 12 of 50

This report includes all changes-through addendum IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISO/DWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments Category C-A MlCl.20.0013 5141-1-HD2 Class 2 NV MCM 1201.06-0015 VT-2 SS 1.075 / 10.920 C01.020.07' Circumferential MC-ISIN3-1554-01.02 Shell To Head REGENERATIVE HEAT EXCHANGER. (Shell 1) Regenerative Heat Exchanger (Shell 1) Shell to Head Weld. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and file Nos. MC-1212.04, MC-1223.04 and MC-1223.11 (Record Retention Code # 000252). If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected. This exam will be performed under the Pressure Test Program, reference McGuire third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISL-1554-01.02 and Plan Addendum M1-PT-023. A VT-2 visual exam will be performed for this weld. Mi.C1.20.0014 5141-2-HD1 Class 2 NV MCM 1201.06-0015 VT-2 SS 1.075 / 10.920 C01.020.07; Circumferential MC-ISIN3-1554-01.02 Nozzle belt To Head REGENERATIVE HEAT EXCHANGER. (Shell 2) Regenerative Heat Exchanger (Shell 2) Nozzle Belt to Head Weld. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and file Nos. MC-1212.04, MC-1223.04 and MC-1223.11 (Record Retention Code # 000252). If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected. This exam will be performed under the Pressure Test Program, reference McGuire third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISL-1554-01.02 and Plan Addendum M1-PT-023. A VT-2 visual exam will be performed for this weld. Printed 01/12/12 GJU8302 v. 06/18/09 SDOA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 13 of 50

This report includes all changes through addendum lMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC.21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThicklNPS Cal Blocks Componenet ID 2 Class / System Description Comments Category C-A M1.C1.20.0015 5141-2-HD2 Class 2 NV MCM 1201.06-0015 VT-2 SS 1.075 / 10.920 C01.020.07" Circumferential MC-ISIN3-1554-01.02 Shell To Head REGENERATIVE HEAT EXCHANGER. (Shell 2) Regenerative Heat Exchanger (Shell 2) Shell to Flange Weld. Code Case N-706 has been incorporated for use during the Third interval which allow an alternative exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and file Nos. MC-1212.04, MC-1223.04 and MC-1223.11 (Record Retention Code # 000252). If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected. This exam will be performed under the Pressure Test Program, reference McGuire third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISL-1554-01.02 and Plan Addendum M1-PT-023. A VT-2 visual exam will be performed for this weld. M1 .C1.30.0006 5141-1-NB-TS Class 2 NV MCM 1201.06-0015 VT-2 SS 1.075 / 10.920 C01.030.02( Circumferential MC-ISIN3-1554-01,02 Nozzle belt To Tubesheet REGENERATIVE HEAT EXCHANGER. (SHELL 1) Regenerative Heat Exchanger (Shell 1) Nozzle Belt to Tubesheet. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and file Nos. MC-1212.04, MC-1223.04 and MC-1223.11 (Record Retention Code # 000252). If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected. This exam will be performed under the Pressure Test Program, reference McGuire third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISL-1554-01.02 and Plan Addendum M1-PT-023. A VT-2 visual exam will be performed for this weld. Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 14 of 50

This report includes all changes through addendum 1IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC.21) Summary Num Component ID ISO/DWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments Category C-A M1.C1.30.0007 5141-1-TS-SH Class 2 NV MCM 1201.06-0015 VT-2 SS 1.075 1 10.920 C01.030.02' Circumferential MC-ISIN3-1554-01.02 Tubesheet To Shell REGENERATIVE HEAT EXCHANGER. (SHELL 1) Regenerative Heat Exchanger (Shell 1) Tubesheet to Shell. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and file Nos. MC-1212.04, MC-1223.04 and MC-1223.11 (Record Retention Code # 000252). Ifevidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected. This exam will be performed under the Pressure Test Program, reference McGuire third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISL-1554-01.02 and Plan Addendum M1-PT-023. A VT-2 visual exam will be performed for this weld. M1.C1.30.0008 5141-2-NB-TS Class 2 NV MCM 1201.06-0015 VT-2 SS 1.075/ 10.920 C01.030.02, Circumferential MC-ISIN3-1554-01.02 Nozzle belt To Tubesheet REGENERATIVE HEAT EXCHANGER. (SHELL 2) Regenerative Heat Exchanger (Shell 2) Nozzle Belt to Tubesheet. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and file Nos. MC-1212.04, MC-1223.04 and MC-1223.11 (Record Retention Code # 000252). Ifevidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected. This exam will be performed under the Pressure Test Program, reference McGuire third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISL-1554-01.02 and Plan Addendum M1-PT-023. A VT-2 visual exam will be performed for this weld. Printed 01/12/12 GJU8302 v. 06/18/09 SDOA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 15 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval,outage 7 (EOC-21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThicklNPS Cal Blocks Componenet ID 2 Class I System Description Comments Category C-A M1.C1.30.0009 5141-2-TS-SH Class 2 NV MCM 1201.06-0015 VT-2 SS 1.075 110.920 C01.030.02= Circumferential MC-ISIN3-1554-01.02 Tubesheet To Shell REGENERATIVE HEAT EXCHANGER. (SHELL 2) Regenerative Heat Exchanger (Shell 2) Tubesheet to Shell. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and file Nos. MC-1212.04, MC-1223.04 and MC-1223.11 (Record Retention Code # 000252). If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected. This exam will be performed under the Pressure Test Program, reference McGuire third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISL-1 554-01.02 and Plan Addendum M1-PT-023. A VT-2 visual exam will be performed for this weld. M1.C1.30.0010 5141-3-NB-TS Class 2 NV MCM 1201.06-0015 VT-2 SS 1.075 /10.920 C01.030.02i Circumferential MC-ISIN3-1554-01.02 Nozzle belt To Tubesheet REGENERATIVE HEAT EXCHANGER. (SHELL 3) Regenerative Heat Exchanger (Shell 3) Nozzle Belt to Tubesheet. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and file Nos. MC-1212.04, MC-1223.04 and MC-1223.11 (Record Retention Code # 000252). Ifevidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected. This exam will be performed under the Pressure Test Program, reference McGuire third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISL-1554-01.02 and Plan Addendum M1-PT-023. A VT-2 visual exam will be performed for this weld. b Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 16 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISO/DWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments Category C-A Ml .Cl .30.0011 5141-3-TS-SH Class 2 NV MCM 1201.06-0015 VT-2 SS 1.075 /10.920 C01.030.02t Circumferential MC-ISIN3-1554-01.02 Tubesheet To Shell REGENERATIVE HEAT EXCHANGER. (SHELL 3) Regenerative Heat Exchanger (shell 3) Tubesheet to Shell. Code Case N-706 has been incorporated for use during the Third Interval which allow an alternative exam (VT-2) for this weld. The Regenerative Heat Exchanger is inside the Class 2 Pressure Test Boundary and will receive a VT-2 exam once each period. For additional information reference PIP G-08-480 and file Nos. MC-1212.04, MC-1223.04 and MC-1223.11 (Record Retention Code # 000252). If evidence of leakage is detected for this item during system leakage test, the NDE Plan Manager will be notified of leakage so evaluation can be performed. Use of this code case shall be discontinued for the heat exchanger and others of the same design or configuration if leakage has been detected. This exam will be performed under the Pressure Test Program, reference McGuire third Inspection Interval Inservice Inspection Plan. Reference drawing MC-ISL-1554-01.02 and Plan Addendum M1-PT-023. A VT-2 visual exam will be performed for this weld. Category C-B Ml .C2.21.0008 1SGD-W259 Class 2 SM MCM 1201.01-0782 NDE-25 MT CS 4.125 / 21.740 C02.021.002, C02.021.002/ Circumferential MC-ISIN3-1591-01.01 MCM 1201.01-0684 Nozzle to Steam Drum STEAM GENERATOR 1D AUXILLARY FEEDWATER NOZZLE. Drawing MCM 1201.01-0735 shows diameter of nozzle as 21.740(+0.000 / -0.015) where it welds to steam drum, and the thickness listed is the thickness of the steam generator. Examiner may use either MT or PT for examination. Ml .C2.21.0008 1SGD-W259 Class 2 SM MCM 1201.01-0782 NDE-820 UT CS 4.125 /21.740 5139385 C02.021, 002, C02.021 .0021 Circumferential MC-ISIN3-1591-01 .01 MCM 1201.01-0684 Nozzle to Steam Drum STEAM GENERATOR 1D AUXILLARY FEEDWATER NOZZLE. Drawing MCM 1201.01-0735 shows diameter of nozzle as 21.740(+0.000 / -0.015) where it welds to steam drum, and the thickness listed is the thickness of the steam generator. Examiner may use either MT or PT for examination. Printed 01/12/12 GJU8302 v.06/18/09 -SD-QACat"C McGuire 1 1/12/2012 6:31:02 AM Page 17 of 50

This report includes all changes through addendum 1MNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThicklNPS Cal Blocks Componenet ID 2 Class I System Description Comments Category C-B M1.C2.21.0008 1SGD-W259 Class 2 SM MCM 1201.01-0782 NDE-640 UT CS 4.125 /21.740 5139385 C02.021.002, C02.021.002, Circumferential MC-ISIN3-1591-01.01 MCM 1201.01-0684 Nozzle to Steam Drum STEAM GENERATOR 1D AUXILLARY FEEDWATER NOZZLE. Drawing MCM 1201.01-0735 shows diameter of nozzle as 21.740(+0.000 1-0.015) where it welds to steam drum, and the thickness listed is the thickness of the steam generator. Examiner may use either MT or PT for examination. Category C-C Ml.C3.10.0004 1REGHX-SUPPORT Class 2 NV MCM 1201.06-0061 NDE-35 PT SS 0.250 1 0.000 C03.010.004 MCM 1201.06-0069 REGENERATIVE HEAT EXCHANGER SUPPORT WELDED ATTACHMENT Code Case N-700 requires only one welded attachment on a component to be examined. For the Regenerative Heat Exchanger Welded Attachment one of the bracket-to-shell connections is required to be examined. Unless otherwise recommended due to radiological considerations, the welded attachment that shall be examined is the bracket shown on drawing MCM 1201.06-015 at the right end of the middle heat exchanger Shell No. II. (Facing the name plate right side) Reference PIP G-08-00499 ACA#2 and CA#5. The vendor drawing (MCM 1201.06-15), as specified in the 1SI Plan, shows the component 180 degrees out from the as installed configuration in the field. Insulation was removed and there was not an integral attachment located at this location as specified on the drawing. Reference PIP M-10-2588 for additional information concerning this exam. This examination moved from EOC-20 to EOC-21 per Plan Addenda 1MNS-070. 00 Ml .C3.20.0057 1-MCA-NV-H459 Class 2 NV MCSRD-NVDIsht. 1 NDE-35 PT SS 0.125 /0.000 C03.020.05E Rigid Restraint MC-ISIN3-1554-03.01 1-MCA-NV-H459 Welded Attachment, inspect with M1.F1.20.0615. The Thickness 0.125 listed is a reference used to identify support as having a welded attachment since thickness can't be determined using the support sketch. If exact dimension is needed a field measurement will be required. Ml .C3.20.0072 1-MCA-CF-H205 Class 2 CF MCSRD-CFC/sht. 12 NDE-25 MT CS 0.594 10.000 C03.020.01" Rigid Support MC-ISIN3-1591-01.01 1-MCA-CF-H205 Welded Attachment, inspect with M1 F11.20.1177 Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 18 of 50

This report includes all changes through addendum lMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC.21) Summary Num Component ID ISO/DWG Numbers Procedure Insp Req Material Sched ThickINPS Cal Blocks Componenet ID 2 Class I System Description Comments Category C-C Ml .C3.20.0075 1-MCA-ND-H31 Class 2 ND MCSRD-FWA/sht. 6 NDE-35 PT SS .0.237 1 0.000 C03.020.02 Spring Hgr MC-ISIN3-1561-01.00 1-MCA-ND-H31 Welded Attachment, inspect with M1 FY1.20.0327 Ml .C3.20.0112 1-MCA-CA-H 186 Class 2 CA MCSRD-CAOIsht. 2 NDE-35 PT SS 0.125 /0.000 C03.020 MC-ISIN3-1592-01.00 Rigid Support Welded Attachment. The Thickness 0.125 listed is a reference used to identify support as having a welded attachment since thickness can't be determined using the support sketch. If exact dimension is needed a field measurement will be required. Welded Attachment, inspect with M1.F1.20.1449. Category C-G M1 .C6.20.0027 I NV-237-1 Class 2 NV MCM 1205.00-1186 NDE-35 PT SS .438/3.000 MC-ISIN3-1554-03.01 Seat Ring Insert To Valve Body NV Valve Group 1. Examine weld on inlet side of valve. These valves added as a result of PIP G-09-0921 CA#9. Ml .C6.20.0028 1NV-237-2 Class 2 NV MCM 1205.00-1186 NDE-35 PT SS .438/3.000 MC-ISIN3-1554-03.01 Seat Ring Insert To Valve Body NV Valve Group 1. Examine weld on outlet side of valve. These valves added as a result of PIP G-09-0921 CA#9. M1 .C6.20.0031 1NV-244A-1 Class 2 NV MCM 1205.00-0142 -NDE-35 PT SS .438/3.000 MC-ISIN3-1554-03.00 Seat Ring Insert To Valve Body NV Valve Group 2. Examine weld on inlet side of valve. These valves added as a result of PIP G-09-0921 CA#9. The Thickness listed is based on pipe size connected to valve and should only be used as a reference since thickness can't be determined using the vendor drawing. If exact dimension is needed a field measurement will be required. Printed 01/12/12 GJU8302 v. 06118109 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 19 of 50

This report includes all changes through addendum 1MNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISO/DWG Numbers Procedure Insp Req Material Sched ThicklNPS Cal Blocks Componenet ID 2 Class I System Description Comments Category C-G M1 .C6.20.0032 1NV-244A-2 Class 2 NV MCM 1205.00-0142 NDE-35 PT SS .438/3.000 MC-ISIN3-1554-03.00 Seat Ring Insert To Valve Body NV Valve Group 2. Examine weld on outlet side of valve. These valves added as a result of PIP G-09-0921 CA#9. Category D-A M1 .D1.20.0058 1-MCA-CA-H84 Class 3 CA MCSRD-CAJ/sht. 1 NDE-65 VT-1 NA 0.125/8,000 D01.020.00' Spring Hgr MC-ISIN3-1592-01.01 1-MCA-CA-H84 Welded Attachment, inspect with Ml .Fl.30.1107 M1 D)1.20.0065 1-MCA-RN-H301 Class 3 RN MCSRD-RN-315 NDE-65 VT-1 NA 0.125 /8.000 D01.020.07' Rigid Support MC-ISIN3-1574-02.00 1-MCA-RN-H301 Welded Attachment, inspect with M1.F1.30.0910 Category F-A M1.F1.10.0022 1-MCR-NC-550 Class 1 NC MCSRD-NC-03/sht. 1 NDE-66 VT-3 NA 0.000 / 4.000 F01.010.022C Spring Hgr M1.F1.10.0023 1-MCR-NC-885 Class 1 NC MCSRD-WL-02/sht. 1 NDE-66 VT-3 NA 0.000 /2.000 F01.010.023/ Rigid Support M1.F1.10.0025 1-MCR-NC-891 Class 1 NC MCSRD-WL-02/sht. 1 NDE-66 VT-3 NA 0.000 / 2.000 F01.010.025C Mech Snubber M1.F1,10.0031 1-MCR-ND-514 Class 1 ND MCSRD-ND-01/sht. 1 NDE-66 VT-3 NA 0.000 114.000 F01.010.056C Spring Hgr MI.F1.10.0050 1-MCR-NI-730 Class 1 NI MCSRD-NI-09/sht. 1 NDE-66 VT-3 NA 0.000 / 2.000 F01.010.119E Rigid Restraint Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 20 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThickINPS Cal Blocks Componenet ID 2 Class I System Description Comments Category F-A M1.F1.10.0051 1-MCR-NI-733 Class 1 NI MCSRD-NI-09/sht. 1 NDE-66 VT-3 NA 0.000 /2.000 F01.010.120C Hyd Snubber Ml .F1.10,0052 1-MCR-NI-858 Class 1 NI MCSRD-NI-16/sht. 1 NDE-66 VT-3 NA 0.000/1.500 F01.010.121C Mech Snubber M1.F1.10.0053 1-MCR-NI-913 Class 1 NI MCSRD-NI-14/sht. 1 NDE-66 VT-3 NA 0.000 1 1.500 F01.010.122C Spring Hgr M1.F1.10.0058 1-MCR-NV-859 Class 1 NV MCSRD-NV-09/sht. 1 NDE-66 VT-3 NA 0.000 / 1.500 F01.010.155E Rigid Restraint M1.Fl 10.0059 1-MCR-NV-895 Class 1 NV MCSRD-NV-07/sht. 1 NDE-66 VT-3 NA 0.000 / 2.000 F01.010.1 56E Rigid Restraint M1.F1.20.0021 1-MCA-FW-H1O Class 2 FW MCSRD-FWAIsht. 1 NDE-66 VT-3 NA 0.000 124.000 F01.020.102C Spring Hgr MC-ISIN3-1571-01.00 M1 .F1.20.0023 1-MCA-FW-H 11 Class 2 FW MCSRD-FWA/sht. 1 NDE-66 VT-3 NA 0.000 / 24.000 F01.020.104/ Rigid Support MC-ISIN3-1571-01.00 M11F1.20.0024 1-MCA-FW-H 111 Class 2 FW MCSRD-FWA/sht. 1 NDE-66 VT-3 NA 0.000 /24.000 F01.020.105C Mech Snubber MC-ISIN3-1571-01.00 M1 .F1.20.0025 1-MCA-FW-H127 Class 2 FW MCSRD-FWA/sht. 1 NDE-66 VT-3 NA 0.000 / 24.000 F01.020.106/ Rigid Support MC-ISIN3-1571-01.00 Ml.F1.20.0033 1-MCA-FW-H2 Class 2 FW MCSRD-FWA/sht. 1 NDE-66 VT-3 NA 0.750 124.000 F01.020.114E Rigid Restraint MC-ISIN3-1571-01.00 Printed 01/12/12 GJU8302 v.06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 21 of 50

This report includes all changes through addendum 1MNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments Category F-A M1 .F1.20.0036 1-MCA-FW-H122 Class 2 FW MCSRD-FWA/sht. 6 NDE-66 VT-3 NA 0.000 1 18.000 F01.020.113C Hyd Snubber MC-ISIN3-1571-01.00 M11F1.20.0037 1-MCA-FW-H110 Class 2 FW MCSRD-FWA/sht. 1 NDE-66 VT-3 NA 0.000 124.000 F01.020.112C Hyd Snubber MC-ISIN3-1571-01.00 MI.F1.20.0094 1-MCR-NI-788 Class 2 NI MCSRD-NI-09/sht. 3 NDE-66 VT-3 NA 0.000/4.000 F01.020.229/ Rigid Support MC-ISIN3-1562-03.00 M1.F1.20.0095 1-MCR-NI-823 Class 2 NI MCSRD-NI-08/sht. 2 NDE-66 VT-3 NA 0.00014.000 F01.020.230/ Rigid Support MC-ISIN3-1562-03.00 Ml. Fl .20.0096 1-MCR-NI-826 Class 2 NI MCSRD-NI-08/sht. 1 NDE-66 VT-3 NA 0.000 /2.000 F01.020.231E Rigid Restraint MC-ISIN3-1562-03.00 M1 .F1.20.0097 1-MCR-NI-853 Class 2 NI MCSRD-NI-15/sht.1 NDE-66 VT-3 NA 0.000 / 3.000 F01.020.232/ Rigid Support MC-ISIN3-1562-01.00 M1 .F1.20.0099 1-MCR-NI-898 Class 2 NI MCSRD-NI-13/sht.1 NDE-66 VT-3 NA 0.000 13.000 F01.020.234E Rigid Restraint MC-ISIN3-1562-01.00 M1.F1.20.0121 1-MCR-NS-659 Class 2 NS MCSRD-NS-04/sht. 2 NDE-66 VT-3 NA 0.000 / 8.000 F01.020.274/ Rigid Support MC-ISfN3-1563-01.00 M1.F1.20.0122 1-MCR-NS-679 Class 2 NS MCSRD-NS-04/sht. 2 NDE-66 VT-3 NA 0.000 /8.000 F01.020.2751 Rigid Support MC-ISIN3-1563-01.00 M11F1.20.0123 1-MCR-NS-709 Class 2 NS MCSRD-NS-05/sht. 2 NDE-66 VT-3 NA 0.000 / 8.000 F01.020.276/ Rigid Support MC-ISIN3-1563-01.00 Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 22 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC.21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments Category F-A M1 .Fl.20.0124 1-MCR-NS-714 Class 2 NS MCSRD-NS-05/sht. 2 NDE-66 VT-3 NA 0.000 / 8.000 F01.020.277W Rigid Support MC-ISIN3-1563-01.00 M1 .F1.20.0327 1-MCA-ND-H31 Class 2 ND MCSRD-FWA/sht. 6 NDE-66 VT-3 NA 0.237 / 14.000 F01.020.178C Spring Hgr MC-ISIN3-1561-01.00 Inspect with Ml .C3.20.0075 M1 .F1.20.0398 1-MCR-VQ-541 Class 2 VQ MCSRD-VQ-01/sht. 1 NDE-66 VT-3 NA 0.000/ 6.000 F01.020.655E Rigid Restraint MC-ISIN3-1585-01.00 M1 .F1.20.0590 1-MCA-NV-H433 Class 2 NV MCSRD-NVA/sht. 9 NDE-66 VT-3 NA 0.000 13.000 F011.020.342C Hyd Snubber MC-ISIN3-1554-01.00 MI .F1.20.0615 1-MCA-NV-H459 Class 2 NV MCSRD-NVD/sht. 1 NDE-66 VT-3 NA 0.125/8.000 F01.020.344E Rigid Restraint MC-ISIN3-1554-03.01 Inspect with Ml .C3.20.0057 M1 .F1.20.0639 1-MCA-NV-H5608 Class 2 NV MCSRD-NVD/sht. 2 NDE-66 VT-3 NA 0.000 / 8.000 F01.020.343C Mech Snubber MC-ISIN3-1554-03.01 M1 .F1.20.0782 1-MCR-NI-505 Class 2 NI MCSRD-NI-01/sht. 1 NDE-66 VT-3 NA 0.000 / 6.000 F01.020.233i Rigid Support MC-ISIN3-1562-03.01 M1.F1.20.1171 1-MCR-CA-H397 Class 2 CA MCSRD-CAN/sht. 1 NDE-66 VT-3 NA 0.000 16.000 F01.020.005C Spring Hgr MC-ISIN3-1592-01.00 M1.Fl.20.1177 1-MCA-CF-H205 Class 2 CF MCSRD-CFC/sht. 12 NDE-66 VT-3 NA 0.594 / 18.000 F01.020.0551 Rigid Support MC-ISIN3-1591-01.01 Inspect with Ml .C3.20.0072 Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 23 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISO/DWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments Category F-A M1.F1.20.1179 1-MCR-CF-H400 Class 2 CF MCSRD-CFC/sht. 12 NDE-66 VT-3 NA 0.000 1 24.000 F01.020.057/ Rigid Support MC-ISIN3-1591-01.01 M1,F1.20,1194 1-MCA-ND-H302 Class 2 ND MCSRD-NDA/sht. 4 NDE-66 VT-3 NA 0.000 1 8.000 F01.020.1751 Rigid Support MC-ISIN3-1561-01.00 M1.F1.20.1195 1-MCA-ND-H304 Class 2 ND MCSRD-NDA/sht. 5 NDE-66 VT-3 NA 0.000 / 8.000 F01.020,176C Hyd Snubber MC-ISIN3-1561-01.00 M1.F1.20.1196 1-MCA-ND-H330 Class 2 ND MCSRD-NDA/sht. 7 NDE-66 VT-3 NA 0.000 18.000 F01.020.1771 Rigid Support MC-ISIN3-1561-01.00 M1.F1.20.1216 1-MCA-ND-H79 Class 2 ND MCSRD-NDA/sht. 8 NDE-66 VT-3 NA 0.000 18.000 F01.020.161/ Rigid Support MC-ISIN3-1561-01.00 M1.F1.20.1226 1-MCA-CA-H468 Class 2 CA MCSRD-CAP/sht. 2 NDE-66 VT-3 NA 0.000 / 6.000 F01.020.013C Mech Snubber MC-ISIN3-1592-01.00 Mi.F1.20.1263 1-MCA-NV-H95 Class 2 NV MCSRD-NVE/sht. 2 NDE-66 VT-3 NA 0.000 / 4.000 FO1.020.337i Rigid Support MC-ISIN3-1554-02.00 M1.F1.20.1264 1-MCA-NV-H 195 Class 2 NV MC-1190-NV-01-03 NDE-66 VT-3 NA 0.000 / 3.000 F01.020.338/ Rigid Support MC-ISIN3-1554-03.01 M1.F1.20.1265 1-MCA-NV-H 197 Class 2 NV MC-1190-NV-01-03 NDE-66 VT-3 NA 0.000 / 3.000 F01.020.339/ Rigid Support MC-ISIN3-1554-03.01 M1.F1.20.1266 1-MCA-NV-H274 Class 2 NV MC-1190-NV-01-03 NDE-66 VT-3 NA 0.000/ 3.000 F01.020.340/ Rigid Support MC-ISIN3-1554-03.01 Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 24 of 50

This report includes all changes through addendum lMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISO/DWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments Category F-A M1.F1.20.1267 1-MCA-NV-H275 Class 2 NV MC-1190-NV-01-02 NDE-66 VT-3 NA 0.000 / 4.000 F01.020.341/ Rigid Support MC-ISIN3-1554-02.01 M1.F1.20.1335 1-MCA-SM-H1 15 Class 2 SM MCSRD-SMA/sht. 2 NDE-66 VT-3 NA 0.000 / 42.000 F01.020.552C Spring Hgr MC-ISIN3-1593-01.00 M1.F1.20.1341 1-MCA-SM-H109 Class 2 SM MCSRD-SMA/sht. 3 NDE-66 VT-3 NA 0.000 / 36.000 F01.020.560i Rigid Support MC-ISIN3-1593-01.03 M1.F1.20.1342 1-MCA-SM-H 140 Class 2 SM MCSRD-SMA/sht. 5 NDE-66 VT-3 NA 0.000/ 36.000 F01.020.5611 Rigid Support MC-ISIN3-1593-01.00 M1.F1.20.1441 1-MCA-CA-H434 Class 2 CA MCSRD-CAO/SHT. 1 NDE-66 VT-3 NA 0.000 / 4.000 F01.020.021 C Hyd Snubber MC-ISIN3-1592-01.00 M1.F1.20.1442 1-MCA-CA-H464 Class 2 CA MCSRD-CAP/SHT. 2 NDE-66 VT-3 NA 0.000 / 4.000 F01.020.022C Mech Snubber MC-ISIN3-1592-01.00 M1.F1.20.1449 1-MCA-CA-H 186 Class 2 CA MCSRD-CAO/sht. 2 NDE-66 VT-3 NA 0.125 / 4.000 F01.020 MC-ISIN3-1592-01.00 Inspect with Ml .C3.20.0112 M1.F1.30.0107 1-MCA-RN-2030 Class 3 RN MCSRD-RN-301/SHT.1 NDE-66 VT-3 NA 0.000 / 18.000 F01.030.186i Rigid Support MC-ISIN3-1574-02.00 Ml.F1.30.0108 1-MCA-RN-1343 Class 3 RN MCSRD-RN-301/SHT.2 NDE-66 VT-3 NA 0.000 130.000 F01.030.187/ Rigid Support MC-ISIN3-1574-01.01 M1.F1.30.0109 1-MCA-RN-2039 Class 3 RN MCSRD-RN-301/SHT.2 NDE-66 VT-3 NA 0.000 / 20.000 F01.030.1881 Rigid Support MC-ISIN3-1574-01.01 Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 25 of 50

This report includes all changes through addendum lMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThicklNPS Cal Blocks Componenet ID 2 Class I System Description Comments Category F-A M 1.F 1.30.0110 1-MCA-RN-H978 Class 3 RN MCSRD-RN-301/SHT.2 NDE-66 VT-3 NA 0.000 / 20.000 F01.030.1891 Rigid Support MC-ISIN3-1574-01.01 MT.F1.30.0111 1-MCA-RN-2023 Class 3 RN MCSRD-RN-301/SHT.3 NDE-66 VT-3 NA 0.000 / 18.000 F01.030.190/ Rigid Support MC-lSIN3-1574-03.00 M1.Fl.30.0112 1-MCA-RN-2327 Class 3 RN MCSRD-RN-301/SHT.4 NDE-66 VT-3 NA 0.000 / 20.000 F01.030.1911 Rigid Support MC-ISIN3-1574-03.00 M1,F1.30.0113 1-MCA-RN-2081 Class 3 RN MCSRD-RN-302 NDE-66 VT-3 NA 0.000 1 8.000 F01.030.1921 Rigid Support MC-ISIN3-1574-02.00 M1.F1.30.0114 1-MCA-RN-1075 Class 3 RN MCSRD-RN-303/SHT.1 NDE-66 VT-3 NA 0.000 / 8.000 F01.030.193/ Rigid Support MC-ISIN3-1574-02.00 M15F1.30.0115 1-MCA-RN-1560 Class 3 RN MCSRD-RN-305/SHT.1 NDE-66 VT-3 NA 0.000/ 6.000 F01.030.194/ Rigid Support MC-ISIN3-1574-01.00 M1 F1.30.0116 1-MCA-RN-2123 Class 3 RN MCSRD-RN-306/SHT.1 NDE-66 VT-3 NA 0.000 / 10.000 F01.030.195/ Rigid Support MC-ISIN3-1574-03.00 M11F1.30.0117 1-MCA-RN-1314 Class 3 RN MCSRD-RN-307/sht.3 NDE-66 VT-3 NA 0.000 /36.000 F01.030.196/ Rigid Support MC-ISIN3-1574-03.00 M1.F1.30.0118 1-MCA-RN-2341 Class 3 RN MCSRD-RN-307/sht.3 NDE-66 VT-3 NA 0.000 / 20.000 F01.030.197/ Rigid Support MC-ISIN3-1574-03.00 M1.F1.30.0119 1-MCA-RN-2339 Class 3 RN MCSRD-RN-307/sht.2 NDE-66 VT-3 NA 0.000 / 20.000 F01.030.198/ Rigid Support MC-ISIN3-1574-02.01 Printed 01/12/12 GJU8302 v. 06118/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 26 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Comnponent ID ISOIDWG Numbers Procedure Insp Req Material Sched ThicklNPS Cal Blocks Componenet ID 2 Clas s I System Description Comments Category F-A M1.F1.30.0120 1-M(CA-RN-H993 Clas .s 3 RN MCSRD-RN-307/sht.4 NDE-66 VT-3 NA 0.000 / 36.000 FO1.030.199/ Rigid Support MC-ISIN3-1574-03.01 M1IF1.30.0121 1-Mi CA-RN-1 105 Clas s 3 RN MCSRD-RN-309/sht.1 NDE-66 VT-3 NA 0.000/6.000 F01.030.200/ Rigid Support MC-ISIN3-1574-01.00 M1.F1.30.0122 1-M(CA-RN-2518 Clas s 3 RN MCSRD-RN-309/sht.3 NDE-66 VT-3 NA 0.000/ 8.000 F01.030.201; Rigid Support MC-ISIN3-1574-01.00 M1.F1.30.0123 1-MiCA-RN-2718 Clas s 3 RN MCSRD-RN-312/sht.2 NDE-66 VT-3 NA 0.000 /8.000 F01.030.202/ Rigid Support MC-ISIN3-1574-02.00 M1.F1.30.0124 1-MiCA-RN-2335 Clas s 3 RN MCSRD-RN-307/SHT.1 NDE-66 VT-3 NA 0.000 /20.000 F01.030.203C Hyd Snubber MC-ISIN3-1574-02.01 M1.F1.30.0125 1-MiCA-RN-2468 Clas s 3 RN MCSRD-RN-307/sht.4 NDE-66 VT-3 NA 0.000 136.000 F01.030.204C Mech Snubber MC-ISIN3-1574-03.01 M1.F1.30.0126 1-MiCA-RN-1302 Clas s 3 RN MCSRD-RN-301/SHT.2 NDE-66 VT-3 NA 0.000/ 20.000 F01.030.205C Spring Hgr MC-ISIN3-1574-01.01 M1.F1.30.0778 1-MiCA-RN-2298 Clas ss 3 RN MCSRD-RN-316 NDE-66 VT-3 NA 0.000 / 8.000 FO1.030.2151 Rigid Support MC-ISIN3-1574-03.00 M1.F1.30.0910 1-MCA-RN-H301 Class 3 RN MCSRD-RN-315 NDE-66 VT-3 NA 0.125 / 8.000 F01.030.216/ Rigid Support MC-ISIN3-1574-02.00 _________ ~~~~~~~~~Inspect withMlDl .20.0065 ___________________________________ M1.F1.30.1107 1-MCA-CA-H84 Class 3 CA MCSRD-CAJ/sht.1 NDE-66 VT-3 NA 0.125 /8.000 F01.030.004C Spring Hgr MC-ISIN3-1592-01.01 Inspect with M1 .D1.20.0058 Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 27 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval,outage 7 (EOC.21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThicklNPS Cal Blocks Componenet ID 2 Class I System Description Comments Category F-A M1 F1.40.0011 1SGC-LATERALS Class 1 NC MC-1070-05.01 NDE-66 VT-3 NA 0.000 1 0.000 F01.040.005C MC-ISIN3-1553-01.00 MC-1070-10.01 STEAM GENERATOR 1C LOWER & UPPER LATERALS AND SNUBBERS. REFERENCE DRAWING MCM 1117.03-0055. M .F1.40.0074 1ELDHX-SUPPORT Class 2 NV MCM 1201.06-10 NDE-66 VT-3 NA 0.375/ 0.000 FO1.040.043E MC-ISIN3-1554-01.02 EXCESS LETDOWN HEAT EXCHANGER SUPPORT M1 .Fl.40.0088 1WNP-SUPPORT-1B2 Class 3 WN MCM 1203.04-0074 NDE-66 VT-3 NA 0.000/ 0.000 F01.040.030E MC-ISIN3-1609-07.00 DIESEL GENERATOR ROOM SUMP PUMP 1832 SUPPORT. M1.F1.40.0104 1CAPTD-SUPPORT Class 3 CA MCM 1201.05-218 NDE-66 VT-3 NA 0.000 10.000 F01.040.03( MC-ISIN3-1592-01.01 AUXILIARY FEEDWATER PUMP TURBINE DRIVEN SUPPORT. M1.F1.40.0112 1SWIF-SUPPORT-1A Class 2 NV MCM 1201.04-0027 NDE-66 VT-3 NA 0.375 /0.000 F01.040.011E MC-ISIN3-1554-02.01 SEAL WATER INJECTION FILTER 1A SUPPORT. Category R-A M1.R1.1 1.0002 1NC1F-1493 Risk Segment NC-02! Class 1 NC MCFI-1NC34 PDI-UT-2 UT SS 160 0.281 /1.500 50202 R01.011.01( MC-ISIN3-1553-01.00 PDI-UT-2-C PDI-UT-2A-M Circumferential MC-1676-4.1 Pipe to SWEEPOLET SEGMENT NC-025. This weld must be ground flush before examination. Contingencies must be addressed to prepare for possible min. wall issues during weld preparation. Printed 01/12112 GJU8302 v.06118/09 SDQA Cat "C" McGuire 1 1/1212012 6:31:02 AM Page 28 of 50

This report includes all changes through addendum lMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments Category R-A Ml.R1.11.0003 1NC1F-1615 Risk Segment NC-02E Class 1 NC MCFI-1 NC44 PDI-UT-2 UT SS 160 0281 11.500 50202 R01.011.011; MC-ISIN3-1553-01.00 PDI-UT-2-C PDI-UT-2A-M Circumferential MC-1676-4.1 Pipe to SWEEPOLET SEGMENT NC-026. This weld must be ground flush before examination. Contingencies must be addressed to prepare for possible min. wall issues during weld preparation. M1.R1.11.0004 1NC1F-1613 Risk Segment NC-02, Class 1 NC MCFI-1NC44 PDI-UT-2 UT SS 160 0.281 /1.500 PDI-UT-2A-M R01.011.01i MC-ISIN3-1553-01.00 50202 PDI-UT-2-C Circumferential MC-1676-4.1 Pipe to SWEEPOLET SEGMENT NC-027. Cal Block 50202 alternate block. This weld must be ground flush before examination. Contingencies must be addressed to prepare for possible min. wall issues during weld preparation. M1.R1.11.0039 1SGC-OUTLET-W6SE Risk Segment NC-007 Class 1 NC MC1676-4 PDI-UT-10 UT SS-CS 4.64 / 29"l.D. 5149697 R01.011.00, MCM 1201.01-0782 5158172 Circumferential Terminal End MCM 1201.01-0769 Dissimilar Nozzle to Safe End STEAM GENERATOR 1C OUTLET NOZZLE. DRAWING # MC-ISiN3-1553-01.00. SEGMENT NC-007. The Thickness and NPS listed are shown on MCM 1201.01-0708. M1.R1.11.0134 1NI1F19 Risk Segment NI-04; Class 2 NI MCFI-1NI93 NDE-998 UT SS 0.134 16.000 8279-0414 R01.011.07i Circumferential MC-ISIN3-1562-03.00 TEE TO ELBOW SEGMENT NI-042 This weld changed from RT to UT per PIP M-09-4090. Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 29 of 50

This report includes all changes through addendum 1MNS-087 McGuire 1, 3rd Interval, outage 7 (EOC.21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThicklNPS Cal Blocks Componenet ID 2 Class I System Description Comments Category R-A Ml.Ri.11.0694 1NI1F249 Risk Segment NI-062/ Class 2 NI MCFI-1 N175 PDI-UT-2 UT SS 0.531 /4.000 PDI-UT-2-C R01.011 MC-ISIN-1562-01.00 PDI-UT-2A-M 50275 Circumferential PEN 351 TO REDUCER This weld replaces M1 .R1.11.0145 (1NI1F364). (1MNS-070). Examination to be done with M1.R1.16.0045. M1.R1.11.2087 1WL1F7651 Risk Segment WL-002A Class 2 WL MCFI-1WL127 NDE-12 RT SS 0.120 / 4.000 R01.011.22" Circumferential MC-ISIN3-1565-01.00 PIPE TO PIPE SEGMENT WL-002A. This weld requires RT that must be performed EOC-21 see PIP M-10-0514. Examination to be done with M1.R1.16.0048 M1.R1.11.2088 1WLP679-1 Risk Segment WL-002P Class 2 WL MCFI-1WL127 NDE-12 RT SS 0.120 / 4.000 R01.011.22; Circumferential MC-ISIN3-1565-01.00 ELBOW TO PIPE SEGMENT WL-002A. This weld requires RT that must be performed EOC-21 see PIP M-10-0515. Examination to be done with M1.R1.16.0049 M1.R1.11.2089 1WL1F3063 Risk Segment WL-009A Class 2 WL MCFI-1WL84 NDE-12 RT SS 0.134 / 6.000 R01.011.22; Circumferential MC-ISIN3-1565-07.00 PIPE TO FLANGE SEGMENT WL-009A. This weld requires RT that must be performed EOC-21 see PIP M-10-0518. Examination to be done with M1.R1.16.0050. M1.R1.11.2090 1WL1 F3062 Risk Segment WL-01O0A Class 2 WL MCFI-1WL84 NDE-12 RT SS 0.134 / 6.000 R01.011.221 Circumferential MC-ISIN3-1565-07.00 PIPE TO ELBOW SEGMENT WL-01 OA. This weld requires RT that must be performed EOC-21 see PIP M-10-0517. Examination to be done with M1.R1.16.0051 Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 30 of 50

This report includes all changes through addendum lMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments Category R-A M1 .R1.1 1.2093 1WL1F3060 Risk Segment WL-010a Class 2 WL MCFI-1WL84 NDE-12 RT SS 0.134 /6.000 R01.011 Circumferential MC-ISIN-1565-07.00 PIPE TO ELBOW This weld was examined in EOC-21 as an elective examination for segment WL-010A per station request. Examination to be done with M1.R1.16.0062, this examination is not required for Risk Informed report totals. M1.R1.11.2095 1WL1F3069 Risk Segment WL-010, Class 2 WL MCFI-1WL84 NDE-12 RT SS 0.134 / 6.000 R01.011 Circumferential MC-ISIN3-1565-07.00 ELBOW TO ELBOW This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program, Procedure NDE-12 to be used. This weld is an additional sample for weld 1WL1F3063. For additional information on this item see PIP M-11-07444. This weld to be done with Summary Number MI.R1.16.0061. M1.R1.1 1.2099 1NVP624-5 Risk Segment NV-001 Class2 NV MCFI-1NV13 PDI-UT-2 UT SS 0.148/8.000 PDI-UT-2-C R01.011.13" MC-ISIN3-1554-03.01 PDI-UT-2A-M 8279-0415 Circumferential ELBOW TO PIPE SEGMENT NV-001. This weld changed from RT to UT per PIP M-09-4090. Examination to be done with M1 .RI.16.0042. M1.R1.1 1.2100 1NV1F2886 Risk Segment NV-002A, Class2 NV MCFI-1NV13 PDI-UT-2 UT SS 0.148/8.000 PDI-UT-2-C R01.01 1.13; MC-ISIN3-1554-03.01 PDI-UT-2A-M 8279-0415 Circumferential PIPE TO ELBOW SEGMENT NV-002AA. This weld changed from RT to UT per PIP M-09-4090. Examination to be done with M1.R1.16.0043. Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 31 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISO/DWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class / System Description Comments Category R-A Ml.R1.11.2111 1NV1FW175-31 Risk Segment NV-019AE Class2 NV MCFI-1NV175 PDI-UT-2 UT SS 0.344 / 2.000 8279-0410 R01.01 1.14' MC-ISIN3-1554-03.00 PDI-UT-2-C PDI-UT-2A-M Circumferential REDUCER TO PIPE SEGMENT NV-019AB. Examination to be done with M1.R1.16.0017. M1.R1.11.2119 1WL1F3059 Risk Segment WL-010, Class 2 WL MCFI-1WL84 NDE-12 RT SS 0.134 /6.000 R01.01 1.22,! Circumferential MC-ISIN3-1565-07.00 ELBOW TO PIPE SEGMENT WL-010A. Rescheduled from EOC-18 to EOC-19 per station. Reference PIP M-07-2311 and M-07-2308. Reference PIP M-08-05999. This weld requires RT that must be performed EOC-21 see PIP M-10-0516. Examination to be done with MI.R1.16.0052. M1.R1.11.2123 1RCHP-IN Risk Segment NV-108A Class 2 NV MCFI-1NV144 NDE-12 RT SS 0.237 / 4.000 R01.011.161, Circumferential MC-ISIN3-1554-03.00 Terminal End MCM 1201.05-0301 Flange to Pump RECIPROCATING CHARGING PUMP. SEGMENT NV-108A.

                                                              *SEE SECTION 8 FOR CALIBRATION BLOCK REQUIREMENTS.

This weld is located on the Reciprocating Charging Pump, downstream of the Reciprocating Charging Pump Suction Stabilizer, at the Reciprocating Charging Pump Inlet Flange to Pump Body. See instructional manual MCM 1201.05-0301 for additional information. Examination to be done with M1.R1.16.0047 M1.R 1.11.2161 1NVIFW175-18 Risk Segment NV-020AE Class 2 NV MCFI-1NV175 PDI-UT-2 UT SS 0.344 / 2.000 8279-0410 R01.01 1.14i MC-ISIN3-1554-03.00 PDI-UT-2-C PDI-UT-2A-M Circumferential Reducer to Pipe SEGMENT NV-020AE. Examination to be done with M1.R1.16.0024. Printed 01112/12 GJU8302 v. 06118109 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 32 of 50

This report includes all changes through addendum lMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISO/DWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments Category R-A M1,R1.11.2171 1NV1 FW53-26 Risk Segment NV-081 Class 2 NV MCFI-1NV53 PDI-UT-2 UT SS 0.436 1 2.000 PDI-UT-2-C R01.01 1.15<` MC-ISIN3-1554-01.02 PDI-UT-2A-M 8279-0411 Circumferential PIPE TO PIPE SEGMENT NV-081. Examination to be done with M1.R1.16.0032. M1.R1.11.2172 1NV1 FW53-30 Risk Segment NV-08. Class 2 NV MCFI-1NV53 PDI-UT-2 UT 55 0.436 /2.000 PDI-UT-2-C R01.011.16( MC-ISIN3-1554-01.02 PDI-UT-2A-M 8279-0411 Circumferential PIPE TO PIPE SEGMENT NV-082. Examination to be done with M1.R31.16.0034. M1.R1.11.2297 1NV50-4 Risk Segment NV-002A Class 2 NV MC-ISIN3-1554-03.01 PDI-UT-2 UT SS 10 0.148/8.000 PDI-UT-2-C R01.011 MCF1-1NV9 PDI-UT-2A-M 8279-0415 Circumferential Pipe to Elbow SEGMENT NV-OO2AA. Examination to be done with M1.R1.16.0058. M1.R1.11.2427 IWLIF3048 Risk Segment WL-010A Class 2 WL MCFI-1WL84 NDE-12 RT SS 0.134 / 6,000 R01.011 Circumferential MC-ISIN3-1565-07.00 ELBOW TO FLANGE This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program, Procedure NDE-12 to be used. This weld is an additional sample for weld 1WL1 F3063. For additional information on this item see PIP M-11-07444. This weld to be done with Summary Number M1.R1.16.0059.

........... .-.. .1 .1..

Printed 01/12112 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 33 of 50

This report includes all changes through addendum lMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Nunm Component ID ISO/DWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments Category R-A M1.R1.11.2428 1WLIF3049 Risk Segment WL-010P Class 2 WL MCFI-1WL84 NDE-12 RT SS 0.134 / 6.000 R01.011 Circumferential MC-ISIN3-1565-07.00 PIPE TO ELBOW This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program, Procedure NDE-12 to be used. This weld is an additional sample for weld 1WL1 F3063. For additional information on this item see PIP M-1 1-07444. This weld to be done __with Summary Number Ml RI.16.00600...... M1.R1. 11.2429 1NV1 FW53-33 Risk Segment NV-08; Class 2 NV MCFI-1NV53 PDI-UT-2 UT SS 0.344 / 2.000 PDI-UT-2-C R01.0101.16" MC-ISIN3-1554-01.02 PDI-UT-2A-M 8279-0410 Circumferential PIPE TO PIPE SEGMENT NV-082. Examination to be done with M1.R1.16.0035. M1,R1.11.2430 1NV1 FW53-40 Risk Segment NV-08 Class 2 NV MCFI-1NV53 PDI-UT-2 UT SS 0.436 / 2.000 PDI-UT-2-C R01.01 1.16; MC-ISIN3-1554-01.02 PDI-UT-2A-M 8279-0411 Circumferential PIPE TO PIPE SEGMENT NV-083. Examination to be done with MI.R1.16.0036. M1.R1.1 1.2431 1NV1 FW53-41 Risk Segment NV-08 Class 2 NV MCFI-1 NV53 PDI-UT-2 UT SS 0.344 /2.000 PDI-UT-2-C R01.01 1.16," MC-ISIN3-1554-01.02 PDI-UT-2A-M 8279-0410 Circumferential PIPE TO PIPE SEGMENT NV-083. Examination to be done with M1.R1.16.0037. Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 34 of 50

This report includes all changes through addendum 1MNS-087 McGuire 1, 3rd Interval,outage 7 (EOC-21) Summary Num C omponent ID ISOIDWG Numbers Procedure Insp Req Material Sched ThicklNPS Cal Blocks Componenet ID 2 C lass I System Description Comments Category R-A M1..R1.11.2434 1NV1FW15-1 Risk Segment NV-002L ( lIass 2 NV MCFI-1NV15 NDE-12 RT SS 0.120 13.000 MC-ISIN-1554-03.01 MC-ISIN-1554-05.00 PIPE TO PIPE This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program.This weld replaces examination scheduled for M1.RI.1 1.2106 (1NVP631-1) the replacement weld allows for better access and exam coverage. See Plan Addendum 1MNS-075 M1.R1.16.0001 1NI1F1134 Risk Segment NI-05 Class 2 NI MCFI-1N121 PDI-UT-2 UT SS 0.250 / 18.000 PDI-UT-2A-M MC-ISIN3-1562-03.01 50325 PDI-UT-2-C PIPE TO ELBOW SEGMENT NI-059. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. M1.R1.16.0002 1N133A-1 Risk Segment NI-05, Class 2 NI MCFI-1 N121 PDI-UT-2 UT SS 0.250 / 18.000 PDI-UT-2A-M MC-ISiN3-1562-03.01 50325 PDI-UT-2-C ELBOW TO ELBOW SEGMENT NI-059. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. M1.R1 .16.0003 1Nl1F1154 Risk Segment NI-06( Class 2 NI MCFI-1 N121 PDI-UT-2 UT SS 0.250 / 18.000 PDI-UT-2A-M MC-ISIN3-1562-03.01 50325 PDI-UT-2-C PIPE TO ELBOW SEGMENT NI-060. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. Printed 01/12/12 GJU8302 v.06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 35 of 50

This report includes all changes through addendum lMNS-087 McGuire 1, 3rd Interval,outage 7 (EOC-21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments Category R-A M1.R1.16.0004 1N132A-2 Risk Segment NI-06( Class 2 NI MCFI-1 N121 PDI-UT-2 UT SS 0.250/ 18.000 PDI-UT-2A-M MC-ISIN3-1562-03.01 50325 PDI-UT-2-C ELBOW TO ELBOW SEGMENT NI-060. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. Remove insulation on RN piping above the NI piping before performing examination on this weld. M1.R1.16.0005 1NI1FW97-1 Risk Segment NI-061/ Class 2 NI MCFI-1 N197 PDI-UT-2 UT SS 0.531 / 4.000 50275 MC-ISIN3-1562-01.00 PDI-UT-2-C PDI-UT-2A-M PIPE TO ELBOW SEGMENT NI-061A. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. M1 R 1.16.0006 1NI93-4 Risk Segment NI-061A Class 2 NI MCFI-1NI97 PDI-UT-2 UT SS 160 0.438 13.000 PDI-UT-2A-M MC-ISIN3-1562-01.00 PDI-UT-2-C 50225 Elbow to Reducer SEGMENT NI-061A. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. Ml Ri.16.0007 1N1267-2 Risk Segment NI-062/ Class 2 NI MCFI-1 N175 PDI-UT-2 UT SS 0.438/ 3.000 PDI-UT-2A-M MC-ISIN3-1562-01.00 PDI-UT-2-C 50225 REDUCER TO PIPE SEGMENT NI-062A. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 36 of 50

This report includes all changes through addendum lMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThickINPS Cal Blocks Componenet ID 2 Class I System Description Comments Category R-A M1.R1.16.0008 1N1227-6 Risk Segment NI-063A Class 2 NI MCFI-1N174 PDI-UT-2 UT SS 0.438 / 3.000 PDI-UT-2A-M MC-ISIN3-1562-01.00 PDI-UT-2-C 50225 REDUCER TO TEE SEGMENT NI-063A. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. M1.R1.16.0009 1N1231-1 Risk Segment NI-063E Class 2 NI MCFI-1N174 PDI-UT-2 UT SS 0.281 /1.500 50202 MC-ISIN3-1562-01.00 PDI-UT-2-C PDI-UT-2A-M Pipe Butt Weld to Reducer SEGMENT NI-0638B. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. M1.R1.16.0010 1 N1270B-13 Risk Segment NI-063E Class 2 NI MCFI-iN175 PDI-UT-2 UT SS 0.281 /1.500 50202 MC-ISIN3-1562-01.00 PDI-UT-2-C PDI-UT-2A-M Pipe to Reducer SEGMENT NI-0638B. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. M1.RI.16.0011 1NVIFW182-13 Risk Segment NV-002E Class2 NV MCFI-1NV182 PDI-UT-2 UT SS 0.237 / 4.000 PDI-UT-2A-M MC-ISIN3-1554-03.00 PDI-UT-2-C 8279-0416 Tee to Pipe SEGMENT NV-002B. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538.

                 ...           .1......

Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 37 of 50

This report includes all changes through addendum lMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThicklNPS Cal Blocks Componenet ID 2 Class I System Description Comments Category R-A M1.R1.16.0012 1NV1F7900 Risk Segment NV-002E Class2 NV MCFI-1NV144 PDI-UT-2 UT SS 0.237 /4.000 PDI-UT-2A-M MC-ISIN3-1554-03.01 PDI-UT-2-C 8279-0416 Pipe to Elbow SEGMENT NV-002B. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. M1.R1.16.0013 1NV29-1 Risk Segment NV-011,A Class 2 NV MCFI-1NV185 PDI-UT-2 UT SS 0.531 / 4.000 50275 MC-ISIN3-1554-03.01 PDI-UT-2-C PDI-UT-2A-M PIPE TO ELBOW SEGMENT NV-011A. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. NV-011[ Segment Risk M1 .R1.16.0014 1NV15-2 Risk Segment NV-011 A Class 2 NV MCFI-1 NV8 PDI-UT-2 UT SS 0.531 /4.000 50275 MC-ISIN3-1554-03.01 PDI-UT-2-C PDI-UT-2A-M Tee to Pipe SEGMENT NV-01 1A. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. M1.1R1.16.0015 1NV1F12A-12 Risk Segment NV-019AA Class2 NV MCFI-1NV10 PDI-UT-2 UT SS 0.438 /3.000 50225 MC-ISIN3-1554-03.00 PDI-UT-2-C PDI-UT-2A-M TEE TO PIPE SEGMENT NV-019AA. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. Printed 01112112 GJU8302 v. 06118109 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 38 of 50

This report includes all changes through addendum 1MNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISO/DWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class / System Description Comments Category R-A M1.R1.16.0016 1NV1FW172-28 Risk Segment NV-019AE Class 2 NV MCFI-1NV172 PDI-UT-2 UT SS 0.344 / 2.000 PDI-UT-2-C MC-ISIN3-1554-03.00 PDI-UT-2A-M 8279-0410 PIPE TO PIPE SEGMENT NV-019AB This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. M1.Rl.16.0017 1NVIFW175-31 Risk Segment NV-019AE Class 2 NV MCFI-1NV175 PDI-UT-2 UT SS 0.344 / 2.000 PDI-UT-2-C MC-ISIN3-1554-03.00 PDI-UT-2A-M 8279-0410 REDUCER TO PIPE SEGMENT NV-019AB. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. Examination to be done with M1.R1.11.2111. M1.R1.16.0018 1NV1FW175-34 Risk Segment NV-019AC Class2 NV MCFI-1NV175 PDI-UT-2 UT SS 0.344 / 2.000 PDI-UT-2-C MC-ISIN3-1554-03.00 8279-0410 PDI-UT-2A-M PIPE TO REDUCER SEGMENT NV-019AC This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PD1-UT-2 to be used reference PIP M-10-3538. M1 .R1.16.0019 INV1FW173-29 Risk Segment NV-019AC Class2 NV MCFI-1NV173 PDI-UT-2 UT SS 0.344 / 2.000 PDI-UT-2-C MC-ISIN3-1554-03.00 8279-0410 PDI-UT-2A-M PIPE TO PIPE SEGMENT NV-019AC This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 39 of 50

This report includes all changes through addendum lMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC.21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThicklNPS Cal Blocks Componenet ID 2 Class I System Description Comments Category R-A M1.R1. 16.0020 1NV77-3 Risk Segment NV-020A Class 2 NV MCFI-1NV13 PDI-UT-2 UT SS 0.438 / 3.000 50225 MC-ISIN3-1554-01.01 PDI-UT-2-C PDI-UT-2A-M Pipe to Reducer SEGMENT NV-020A. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. M1.R1.16.0021 1NVlFW181-25 Risk Segment NV-020AP Class 2 NV MCFI-1NV181 PDI-UT-2 UT SS 0.344 / 2.000 PDI-UT-2-C MC-ISIN3-1554-03.00 8279-0410 PDI-UT-2A-M PIPE TO PIPE SEGMENT NV-020AA This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. M1.R1.16.0022 N V1NFW181-24 Risk Segment NV-020M Class 2 NV MCFI-INV181 PDI-UT-2 UT SS 0.344 / 2.000 PDI-UT-2-C MC-ISIN3-1554-03.00 8279-0410 PDI-UT-2A-M PIPE TO PIPE SEGMENT NV-020AA This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. Ml.Ri.16.0024 1NV1FW175-18 Risk Segment NV-020AE Class 2 NV MCFI-1NV175 PDI-UT-2 UT SS 0.344 / 2.000 PDI-UT-2-C MC-ISIN3-1554-03.00 8279-0410 PDI-UT-2A-M Reducer to Pipe SEGMENT NV-020AE. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. Examination to be done with MI.R1.11.2161. Printed 01/12/12 GJU8302 v. 06/18109 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 40 of 50

This report includes all changes through addendum 1MNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISO/DWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class / System Description Comments Category R-A MI.R1 .16.0025 1NVP888-1 Risk Segment NV-020AF Class2 NV MCFI-1NV175 PDI-UT-2 UT SS 0.344 / 2.000 PDI-UT-2-C MC-ISIN3-1554-03.00 8279-0410 PDI-UT-2A-M Reducer to Pipe SEGMENT NV-020AF. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. M1.R1.16.0026 1NV1FW173-13 Risk Segment NV-020AF Class2 NV MCFI-1NV173 PDI-UT-2 UT SS 0.344 / 2.000 PDI-UT-2-C MC-ISIN3-1554-03.00 8279-0410 PDI-UT-2A-M PIPE TO PIPE SEGMENT NV-020AF. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. M1.R1.16.0027 1NV1F2112 Risk Segment NV-020AC Class 2 NV MCFI-1NV63 PDI-UT-2 UT SS 0.344 / 2.000 PDI-UT-2-C MC-ISIN3-1554-01.00 8279-0410 PDI-UT-2A-M PIPE TO REDUCER SEGMENT NV-020AG. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. M1.R1.16.0028 1NV1F331 Risk Segment NV-0201A Class 2 NV MCFI-1NV5 PDI-UT-2 UT SS 0.344 / 2.000 PDI-UT-2-C MC-ISIN3-1554-01.00 8279-0410 PDI-UT-2A-M PIPE TO REDUCER SEGMENT NV-0201A. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. Printed 01/12/12 GJU8302 v. 06118/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 41 of 50

This report includes all changes through addendum lMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISO/DWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments Category R-A M1.R1.16.0029 INV3-3 Risk Segment NV-06! Class 2 NV MCFI-1NV185 PDI-UT-2 UT SS 0.438 / 3.000 50225 MC-ISIN3-1554-03.00 PDI-UT-2-C PDI-UT-2A-M ELBOW TO PIPE SEGMENT NV-065. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. M1.R1.16.0030 INV1F6223 Risk Segment NV-077E Class2 NV MCFI-1NV145 PDI-UT-2 UT SS 0.344 / 2.000 PDI-UT-2-C MC-ISIN3-1554-01.02 8279-0410 PDI-UT-2A-M REDUCER TO PIPE SEGMENT NV-077B. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. M1.R1 .16.0031 1NV1 FW53-27 Risk Segment NV-081 Class 2 NV MCFI-1NV53 PDI-UT-2 UT SS 0.436 12.000 8279-0411 MC-ISIN3-1554-01.02 PDI-UT-2-C PDI-UT-2A-M VALVE TO PIPE SEGMENT NV-0811. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. M1 .R1.16. 0032 1NV1 FW53-26 Risk Segment NV-081 Class 2 NV MCFI-1NV53 PDI-UT-2 UT SS 0.436 /2.000 8279-0411 MC-ISIN3-1554-01.02 PDI-UT-2-C PDI-UT-2A-M PIPE TO PIPE SEGMENT NV-081. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. Examination to be done with M1.R1.11.2171. Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 42 of 50

This report includes all changes through addendum lMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC.21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThickINPS Cal Blocks Componenet ID 2 Class I System Description Comments Category R-A M1.R1.16.0034 1NV1 FW53-30 Risk Segment NV-08, Class 2 NV MCFI-1NV53 PDI-UT-2 UT SS 0.436 / 2.000 8279-0411 MC-ISIN3-1554-01.02 PDI-UT-2-C PDI-UT-2A-M PIPE TO PIPE SEGMENT NV-082. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. Examination to be done with M1.R1.11.2172. NV-08; Segment Risk M1.R1.16.0035 1NV1 FW53-33 Risk Segment NV-08, Class 2 NV MCFI-1NV53 PDI-UT-2 UT SS 0.344 / 2.000 8279-0410 MC-ISIN3-1554-01.02 PDI-UT-2-C PDI-UT-2A-M PIPE TO PIPE SEGMENT NV-082. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. Examination to be done with M1.R1.11.2429. M1.R1.16.0036 1NV1 FW53-40 Risk Segment NV-08" Class 2 NV MCFI-1NV53 PDI-UT-2 UT SS 0.436 / 2.000 8279-0411 MC-ISIN3-1554-01.02 PDI-UT-2-C PDI-UT-2A-M PIPE TO PIPE

  • SEGMENT NV-083. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538.

Examination to be done with M1 .R1.11.2430. M1.R1.16.0037 1NV1 FW53-41 Risk Segment NV-08,: Class 2 NV MCFI-1NV53 PDI-UT-2 UT SS 0.344 /2.000 PDI-UT-2-C MC-ISIN3-1554-01.02 8279-0410 PDI-UT-2A-M PIPE TO PIPE SEGMENT NV-083. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. Examination to be done with Ml .R1.11.2431. Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 43 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments Category R-A M1 .R1.16.0038 1RCPSS-OUT-1 Risk Segment NV-108, Class 2 NV MCFI-1NV144 PDI-UT-2 UT SS 0.237 14.000 8279-0416 MC-ISIN3-1554-03.00 PDI-UT-2-C PDI-UT-2A-M Terminal End MCM 1201.04-0272 Pipe to Flange RECIPROCATING CHARGING PUMP SUCTION STABILIZER. SEGMENT NV-108A. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. M1.R1.16.0040 1NV1 F479 Risk Segment NV-11O0A Class 2 NV MCFI-1 NV1 1 PDI-UT-2 UT SS 0.438 / 3.000 50225 MC-ISIN3-1554-03.00 PDI-UT-2A-M PDI-UT-2-C ELBOW TO PIPE SEGMENT NV-110A. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. M1 .R1.16.0041 1 NVl F4823 Risk Segment NV-11OE Class 2 NV MCFI-1NV3 PDI-UT-2 UT SS 0.344 1 2.000 PDI-UT-2-C MC-ISIN3-1554-03.00 8279-0410 PDI-UT-2A-M REDUCER TO PIPE SEGMENT NV-1 10B This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. MI .Ri.16.0042 1NVP624-5 Risk Segment NV-001 Class 2 NV MCFI-1NV13 PDI-UT-2 UT SS 0.148 /8.000 8279-0415 MC-ISIN3-1554-03.01 PDI-UT-2A-M PDI-UT-2-C ELBOW TO PIPE SEGMENT NV-001. This weld changed from RT to UT per PIP M-09-4090. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. Examination to be done with M1.R1.11.2099. Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM. Page 44 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched ThickINPS Cal Blocks Componenet ID 2 Class I System Description Comments Category R-A Ml.R1.16.0043 1NV1 F2886 Risk Segment NV-002AP Class2 NV MCFI-1NV13 PDI-UT-2 UT SS 0.148/ 8.000 8279-0415 MC-ISIN3-1554-03.01 PDI-UT-2A-M PDI-UT-2-C PIPE TO ELBOW SEGMENT NV-OO2AA. This weld changed from RT to UT per PIP M-09-4090. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. Examination to be done with Ml.R1.1 1.2100. M1 .R1.16.0045 1NI1F249 Risk Segment NI-062A Class 2 NI MCFI-1 N175 PDI-UT-2 UT SS 0.531 /4.000 PDI-UT-2-C MC-ISIN-1562-01.00 PDI-UT-2A-M 50275 PEN 351 TO REDUCER This weld replaces M1.R1.11.0145 (1Ni1 F364). (1MNS-070) This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. Examination to be done with M1.R1.11.0694. M1.R1.16.0047 1RCHP-IN Risk Segment NV-108A Class 2 NV MCFI-1NV144 NDE-12 RT SS 0.237 /4.000 MC-ISIN3-1554-03.00 Terminal End MCM 1201.05-0301 Flange to Pump RECIPROCATING CHARGING PUMP, SEGMENT NV-108A.

                                                               *SEE SECTION 8 FOR CALIBRATION BLOCK REQUIREMENTS.

This weld is located on the Reciprocating Charging Pump, downstream of the Reciprocating Charging Pump Suction Stabilizer, at the Reciprocating Charging Pump Inlet Flange to Pump Body. See instructional manual MCM 1201.05-0301 for additional information. This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program, Procedure NDE-12 to be used reference PIP M-10-3538. Examination to be done with M1.R1.11.2123. Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 45 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISO/DWG Numbers Procedure Insp Req Material Sched ThickINPS Cal Blocks Componenet ID 2 Class I System Description Comments Category R-A M1.R1.16.0048 IWL1F7651 Risk Segment WL-002P Class 2 WIL MCFI-1WL127 NDE-12 RT SS 0.120 /4.000 MC-ISIN3-1565-01.00 PIPE TO PIPE SEGMENT WL-002A. This weld requires RT that must be performed EOC-21 see PIP M-10-0514. This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program, Procedure NDE-12 to be used reference PIP M-10-3538. Examination to be done with M1 .R1.11.2087. WL-002,* Segment Risk M1.R1.16.0049 1WLP679-1 Risk Segment WL-002P Class 2 WL MCFI-1WL127 NDE-12 RT SS 0.120 /4.000 MC-ISIN3-1565-01.00 ELBOW TO PIPE SEGMENT WL-002A. This weld requires RT that must be performed EOC-21 see PIP M-10-0515. This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program, Procedure NDE-12 to be used reference PIP M-10-3538. Examination to be done with M1 .R1.11.2088. M1.R1.16 .0050 1WL1F3063 Risk Segment WL-009P Class 2 WL MCFI-1WL84 NDE-12 RT SS 0.134 / 6.000 MC-ISIN3-1565-07.00 PIPE TO FLANGE SEGMENT WL-009A. This weld requires RT that must be performed EOC-21 see PIP M-10-0518. This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program, Procedure NDE-12 to be used reference PIP M-10-3538. Examination to be done with M1.R1.11.2089. M1.R1.16.0051 1WL1F3062 Risk Segment WL-01OP Class 2 WL MCFI-1WL84 NDE-12 RT SS 0.134 / 6.000 MC-ISIN3-1565-07.00 PIPE TO ELBOW SEGMENT WL-010A. This weld requires RT that must be performed EOC-21 see PIP M-10-0517. This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program, Procedure NDE-12 to be used reference PIP M-10-3538. Examination to be done with M1.R1.11.2090. Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 46 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments Category R-A Ml.Ri.16.0052 1WL1F3059 Risk Segment WL-010A CI ass 2 WL MCFI-1WL84 NDE-12 RT SS 0.134 /6.000 MC-ISIN3-1565-07.00 ELBOW TO PIPE SEGMENT WL-010A. Rescheduled from EOC-18 to EOC-19 per station. Reference PIP M-07-2311 and M-07-2308. Reference PIP M-08-05999. This weld requires RT that must be performed EOC-21 see PIP M-10-0516. This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program, Procedure NDE-12 to be used reference PIP M-10-3538. Examination to be done with M1.R1.11.2119. M1.R1.16.0053 IN 1V39-1 Risk Segment NV-002AE CI ass2 NV MCFI-1NV8 NDE-12 RT SS 0.134 /6.000 MC-ISIN3-1554-03.01 ELBOW TO ELBOW SEGMENT NV-002AB. Rescheduled from EOC-18 to EOC-19 per station. Reference PIP M-07-1906. This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program. Procedure NDE-12 to be used reference PIP M-10-3538. (NOTE) This exam was performed under Summary Number M1.R1.11.2102 during EOC-19. No additional RT examination will be performed during EOC-21. M1.R1.16.0054 1NIV37-3 Risk Segment NV-002AE Cl ass2 NV MCFI-1NV8 NDE-12 RT SS 0.134 / 6.000 MC-ISIN3-1554-03.01 ELBOW TO PIPE SEGMENT NV-002AB. Rescheduled from EOC-18 to EOC-19 per station. Reference PIP M-07-1906. This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program. Procedure NDE-12 to be used reference PIP M-1 0-3538. (NOTE) This exam was performed under Summary Number M1.R1.11.2103 during EOC-19. No additional RT examination will be performed during EOC-21. Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 47 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments Category R-A Ml.Rl.16.0055 INV614-1 Risk Segment NV-020AC Class 2 NV MCFI-1 NV5 PDI-UT-2 UT SS 0.344 12.000 8279-0410 MC-ISIN-1554-01.00 PDI-UT-2-C PDI-UT-2A-M MC-ISIN-1554-01.01 FLANGE TO PIPE SEGMENT NV-020AG, This weld replaces weld 1NV1F354 (M1.R1.1 1.1358) for ISI Plan Segment. This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. Examination for Ml.Ri.11.2164 was performed in EOC-16. Ml .R1.16.0056 1RCPA-IN-2 Risk Segment NV-10 Class 2 NV MCFI-1NV11 , PDI-UT-2 UT SS 0.438 I 3.000 50225 MC-ISIN-1554-03.00 PDI-UT-2A-M PDI-UT-2-C MCM-1 201.04-0197 TEE TO PIPE Reference PIP M-07-1351. This summary number is a possible replacement for Summary Number MI.Ri.11.2124 ID# 1RCPA-TE where limited examination coverage (35.4%) was obtained. Only one Summary Number (M1 .R1.11.2410 or Ml .Ri.11.2411) is required for examination. Coverage greated than 90% required to credit examination of one of these welds. The weld crown must be removed before examination can be performed on weld selected for examination. This weld was selected as the replacement for M1.R1.11.2124. This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program, Procedure PDI-UT-2 to be used reference PIP M-10-3538. Examination for M1.Ri. 1.2411 was performed in EOC-20. M1 .Ri.16.0057 INVlFW15-1 Risk Segment NV-002L Class 2 NV MCFI-1NV15 NDE-12 RT SS 0.120 / 3.000 MC-ISIN-1554-03.01 MC-ISIN-1554-05.00 PIPE TO PIPE This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program. This weld replaces examination scheduled for M1.R1.16.0046 (1NVP631-1) the replacement weld allows for better access and exam coverage. See Plan Addendum 1MNS-075 Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 48 of 50

This report includes all changes through addendum lMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISO/DWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class / System Description Comments Category R-A M1.R1.16.0058 1NV50-4 Risk Segment NV-002AM Class 2 NV MC-ISIN3-1554-03.01 PDI-UT-2 UT SS 10 0.148 / 8.000 8279-0415 MCF1-1NV9 PDI-UT-2A-M PDI-UT-2-C Circumferential Pipe To Elbow SEGMENT NV-002AA. This weld is considered (IGSCC) for the Risk Informed Inservice Inspection Program. Examination to be done with Ml. R 1.11.2297. M 1.R 1.16.0059 1WL1F3048 Risk Segment WL-010a Class 2 WL MCFI-1WL84 NDE-12 RT SS 0.134 / 6.000 MC-ISIN3-1565-07.00 ELBOW TO FLANGE This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program, Procedure NDE-12 to be used. This weld is an additional sample for weld 1WL1F3063. For additional information on this item see PIP M-1 1-07444. This weld to be done with Summary Number MI .R1.11.2427. M1.R1.16.0060 1WL1F3049 Risk Segment WL-010a Class 2 WL MCFI-1WL84 NDE-12 RT SS 0.134 / 6.000 MC-ISIN3-1565-07.00 PIPE TO ELBOW This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program, Procedure NDE-12 to be used. This weld is an additional sample for weld 1WL1 F3063. For additional information on this item see PIP M-11-07444. This weld to be done with Summary Number M1.R1.11.2428. M1.R1.16.0061 1WL1F3069 Risk Segment WL-010P Class 2 WL MCFI-1WL84 NDE-12 RT SS 0.134 / 6.000 MC-ISIN3-1565-07.00 ELBOW TO ELBOW This weld is considered (IGSCC) for Risk Informed Inservice Inspection Program, Procedure NDE-12 to be used. This weld is an additional sample for weld 1WL1F3063. For additional information on this item see PIP M-1 1-07444. This weld to be done with Summary Number M1 RR1.11.2095. M1.R1.16.0062 1WL1F3060 Risk Segment WL-010A Class 2 WL MCFI-1WL84 NDE-12 RT SS 0.134 / 6.000 Circumferential MC-ISIN-1565-07.00 PIPE TO ELBOW This weld was examined in EOC-21 as an elective examination for segment WL-01OA per station request. Examination to be done with M1.R1.11.2093, this examination is not required for Risk Informed report totals. Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 49 of 50

This report includes all changes through addendum IMNS-087 McGuire 1, 3rd Interval, outage 7 (EOC-21) Summary Num Component ID ISOIDWG Numbers Procedure Insp Req Material Sched Thick/NPS Cal Blocks Componenet ID 2 Class I System Description Comments End of Report S TA TIS TICS ONL Y Class 1 42 Class 2 151 Class 3 27 Total by Class 220 Systems 220 Total Count 220 Printed 01/12/12 GJU8302 v. 06/18/09 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 50 of 50

4.0 Results of Inspections Performed The results of each examination shown in the final Inservice Inspection Plan (Section 3 of this report) are included in this section. The completion date and status for each examination are shown. All examinations revealing reportable indications and any corrective action required as a result are described in further detail in Subsections 4.1 and 4.2. Corrective measures performed and limited examinations are described in further detail in Subsections 4.3 and 4.4. 4.1 Reportable Indications EOC 21 (Outage 7) had no reportable indications during this report period, 4.2 CorrectiveAction Corrective action is action taken to resolve flaws and relevant conditions, including supplemental examinations, analytical evaluations, repair / replacement activities, and corrective measures. There were no recordable conditions that required corrective action during this report period. 4.3 Corrective Measures Corrective measures are actions (such as maintenance) taken to resolve relevant conditions, but not including supplemental examinations, analytical evaluations, and repair / replacement activities. Any corrective measures performed for examinations associated with this report period will be shown on the examination data sheets which are on file at the Duke's Corporate Office in Charlotte, North Carolina. 4.4 Limited Examinations Limitations (i.e., 90% or less of the required examination coverage obtained) identified for examinations associated with this report period are shown below. A relief request will be submitted to seek NRC acceptance of the limited coverage. This information will be on file at the Duke's Corporate Office in Charlotte, North Carolina. Welds 1NV1F7908 and WI1F3063 had PSI exams performed during 1EOC-21. These welds had less than 90% exam coverage; reference PIP M-1 1-9036 for the limitation coverage on these welds. Outage 7/EOC 21 Refueling Outage Report Page 1 of 2 McGuire Unit 1 Revision 0 Section 4 January 12, 2012

Summary Description of Limitation Number M1..B1.21.0001 Reference PIP M-11-9036 M1.R1.11.0002 Reference PIP M-1 1-9036 M1.R1.11.0003 Reference PIP M-11-9036 Ml.R1.11.0004 Reference PIP M-1 1-9036 M1.Rl.11.2123 Reference PIP M-11-9036 M1.R1.16.0009 Reference PIP M-11-9036 Ml .R1.16.0025 Reference PIP M-11-9036 Ml.R1.16.0031 Reference PIP M-11-9036 Ml .R1.16.0047 Reference PIP M-11-9036 Outage 7/EOC 21 Refueling Outage Report Page 2 of 2 McGuire Unit 1 Revision 0 Section 4 January 12, 2012

DUKE ENERGY CORPORATION QUALITY ASSURANCE TECHNICAL SERVICES Scheduleworks Inservice Inspection DatabaseManagement System Inspection Results McGuire 1, 3rd Interval Outage 7 (EOC-2)_0C-2_1) Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M1..B1.21.0001 1RPV6-446B NC 03/30/07 CLR Y N Y UT-n/a This weld was not examined during EOC-21 it was determined no addition coverage could be achieved. Reference PIP M-07-2243 for history on this weld examined during EOC-18. PIP M-11-09036 was written to determine the corrective action for the limited coverage obtained for this item. MI.B10.10.0002 1PZR-SKIRT NC 09/26/11 CLR N N N MT-11-054 M1.B15.80.0001 1-RPV-BMI-Nozzles NC 09/20/11 CLR N N N VT-11-623 M1 .B15.90.0001 1 RPV3-445E-SE NC 10/07/11 CLR N N N VT-11-649 M1.B15.90.0002 1 RPV3-445F-SE NC 10/07/11 REC N N N VT-11-647 Dried boron on weld inspection area. Reference PIP M-1 1-7710 and WR# 1044803 boron and flaking rust were removed. M1.B15.90.0003 1RPV3-445G-SE NC 10/07/11 REC N N N VT-11-646 Dried boron on weld inspection area. Reference PIP M-11-7710 and WR# 1044803 boron and flaking rust were removed. M1.115.90.0004 1RPV3-445H-SE NC 10/07/11 CLR N N N VT-11-650 M1.B15.95.0003 1RPV3-445C-SE NC 10/07/11 REC N N N VT-11-648 Dried boron on weld inspection area. Reference PIP M-1 1-7710 and WR# 1044803 boron and flaking rust were removed. M1.615.95.0004 1RPV3-445D-SE NC 10/07/11 CLR N N N VT-11-651 Printed 1/12/2012 6:33:57 AM GJU8302 v. 01/01/08 SD( PA Cat "C" McGuire1 1/12/2012 6:31:02 AM Page 1 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M1.182.12.0002 1PZR-9 NC 09/23/11 CLR N N N UT-1 1-220 (Page 1) NC 09/23/11 CLR N N N UT-11-220 (Page 2) NC N N N M1.1B3.100.0009 1RPV1-462A-IR 09/29/11 CLR VT-1 1-641 NC N N N M1.183. 100.0010 1RPV1-462B-IR 09128/11 CLR VT-1 1-642 NC N N N M1.183.100.0011 1RPV1-462C-IR 09/29/11 CLR VT-1 1-643 NC N N N M1.B3.100.0012 1RPV1-462D-IR 09/29/11 CLR VT-1 1-644 NC N N N M1.184.10.0001 1RPV-Head 09/27/11 CLR VT-1 1-640 1SGC-MW-X2-Y1 NC N N N M1 .B6.110.0001 09/26/11 CLR VT-1 1-636 1SGC-MW-X2-Y2 NC N N N M1 .86.110.0002 09/26/11 CLR VT-1 1-635 1SGB-MW-Xl-Y1 NC N N N M1.136.110.0007 09/26/11 CLR VT-1 1-637 NC N N N M1.186.110.0008 1SGB-MW-X1-Y2 09/26/11 CLR VT-1 1-638 N N N M1.87.70.0011 1N1-175 NI 09/19/11 CLR VT-11-618 M1.C1.10.0001 1RHR-1A-3-4 ND 11/11/11 CLR N N N VT/n/a Zone 1ND-019L-B completed on this date, which includes this pressure test. Printed 1/12/2012 6:33:57 AM GJU8302 v. 01/01/08 SDOA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 2 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment Ml.Cl.10.0005 1RHR-1B-3-4 ND 11/11/11 CLR N N N VT n/a Zone 1ND-019L-B completed on this date, which includes this pressure test. Ml .C1.20.0001 5141-3-HD1 NV 11/10/11 CLR N N N VT n/a Zone 1NV-018L-B completed on this date, which includes this pressure test. MI .C1.20.0002 5141-3-HD2 NV 11/10/11 CLR N N N VT n/a Zone 1NV-018L-B completed on this date, which includes this pressure test. Ml .C1.20.0006 1RHR-1 B-2-3 ND 11/11/11 CLR N N N VT n/a Zone 1ND-01 9L-B completed on this date, which includes this pressure test. Ml.C1.20.0011 1RHR-1A-2-3 ND 11/11/11 CLR N N N VT n/a Zone 1ND-019L-B completed on this date, which includes this pressure test. M1.C1.20.0012 5141-1-HD1 NV 11/10/11 CLR N N N VT nla Zone 1NV-018L-B completed on this date, which includes this pressure test. Ml.C1.20.0013 5141-1 -HD2 NV 11/10/11 CLR N N N VT n/a Zone 1NV-018L-B completed on this date, which includes this pressure test. M1 .C1.20.0014 5141-2-HDI NV 11/10/11 CLR N N N VT n/a Zone 1NV-018L-B completed on this date, which includes this pressure test. M1.C1.20.0015 5141-2-HD2 NV 11/10/11 CLR N N N VT n/a Zone INV-018L-B completed on this date, which includes this pressure test. Printed 1/12/2012 6:33:57 AM GJU8302 v. 01101/08 SDQA Cat "C" McGuire 1/12/2012 6:31:02 AM Page 3 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M1.C1.30.0006 5141-1-NB-TS NV 11/10/11 CLR N N N VT n/a Zone 1NV-018L-B completed on this date, which includes this pressure test. M1 .C1.30.0007 5141-1-TS-SH NV 11/10/11 CLR N N N VT n/a Zone 1NV-018L-B completed on this date, which includes this pressure test. M1 .C1.30.0008 5141-2-NB-TS NV 11/10/11 CLR N N N VT n/a Zone 1NV-018L-B completed on this date, which includes this pressure test. Ml .C1.30.0009 5141-2-TS-SH NV 11/10/11 CLR N N N VT n/a Zone 1NV-018L-B completed on this date, which includes this pressure test. M1 .C1.30.0010 5141-3-NB-TS NV 11/10/11 CLR N N N VT n/a Zone 1NV-018L-B completed on this date, which includes this pressure test. M1.C1.30.0011 5141-3-TS-SH NV 11/10/11 CLR N N N VT n/a Zone 1NV-018L-B completed on this date, which includes this pressure test. Ml .C2.21.0008 1SGD-W259 SM 09/23/11 CLR N N N MT-1 1-053 SM 09/23/11 CLR N N N UT-11-230 SM 09/23/11 CLR Y N N UT-11-231 Page 1 Limitation in axial scans (S1, S2) this is due to adjacent band SM 09/23/11 CLR Y N N UT-11-231 Page 2 Limitation in axial scans (S1, S2) this is due to adjacent band Ml .C3.10.0004 1REGHX-SUPPORT NV 09/23/11 CLR N N N PT-11-040 McGuire 1 1/12/2012 6:31 :02 AM Page 4 of 28 Printedv. Printed 1/12/2012 6:33:57 AM GJU8302 01/01/08 6:33:57 AMGJU8302

v. 1/12/2012 01/01/08 SDQA Cat SOQA Cat "C' "C" McGuire 1 1/12/2012 6:31:02 AM Page 4 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment Ml .C3.20.0057 1-MCA-NV-H459 NV 09/07/11 CLR N N N PT-1 1-031 Ml .C3.20.0072 1-MCA-CF-H205 CF 09/19/11 CLR N N N MT-1 1-052 CLR N N PT-i 1-032 Ml .C3.20.0075 1-MCA-ND-H31 ND 09/08/11 N CLR N N PT-1 1-030 M1.C3.20.0112 1-MCA-CA-H 186 CA 08/30/11 N CLR N N PT-1 1-033 M1 0C6.20.0027 1 NV-237-1 NV 09/14/11 N CLR N N PT-1 1-034 Mi .C6.20.0028 1 NV-237-2 NV 09/14/11 N CLR N N PT-1 1-035 M1 .C6.20.0031 1NV-244A-1 NV 09/13/11 N CLR N N PT-1 1-036 Mi .C6.20.0032 1NV-244A-2 NV 09/13/11 N CLR N N MI.D1.20.0058 1-MCA-CA-H84 CA 09/06111 N VT-1 1-581 CLR N N M .D1.20.0065 1-MCA-RN-H301 RN 09/12/11 N VT-1 1-580 CLR N N M1.F1.10.0022 1-MCR-NC-550 NC 09121/11 N VT-1 1-626 CLR N N M1.F1.10.0023 1-MCR-NC-885 NC 09/19/11 N VT-1 1-612 CLR N N M1.F1.10.0025 1-MCR-NC-891 NC 09/19/11 N VT-1 1-616 CLR N N Mt.Fi.10.0031 I-MCR-ND-514 ND 09121/11 N VT-1 1-627 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 5 of 28 Printed 1/12/20126:33:57AMGJU8302v.01/01/08 Printed 1/12/2012 6:33:57 AMGJU8302 v. 01/01/08 SDQA Cat "C" McGuirel 1/12/20126:31:02AM Page 5of28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M1.F1.10.0050 1-MCR-NI-730 NI 09/19/11 REC N N N VT-11-611 The hanger sketch calls for 1/16" gap between pipe and the top of Item #2. WR

                                                                                                   # 01044706 was originated to modify existing shims beneath pipe to provide the required clearance. ENG. evaluation: This is not an operability concern, due to accumulation of paint , dust, and rust. This accumulation of material would not impair thermal movement of the pipe.

M1.F1. 10.0051 1-MCR-NI-733 NI 09/19/11 CLR N N VT-1 1-613 MI. Fl. 10.0052 1-MCR-NI-858 NI 09/19/11 CLR N N VT-1 1-608 M1.F1.10.0053 1-MCR-NI-913 NI 09/21/11 REC N N VT-1 1-624 Vertical centedine of spring can is 1.25" from vertical center line of items 3, 4, and 6. EC106606 was written to revise hanger sketch and calculation to update information to show new tolerances. No operability issue for this support M1.F1.10.0058 1-MCR-NV-859 NV 09/19/11 CLR N N VT-11-614 M1.F1.10.0059 1-MCR-NV-895 NV 09/21/11 CLR N N VT-1 1-625 M1.F1.20.0021 1-MCA-FW-H1O FW 08/29/11 CLR N N VT-i 1-563 M1.F1.20.0023 1-MCA-FW-H11 FW 08/29/11 CLR N N VT-1 1-562 M1.F1.20.0024 1-MCA-FW-H111 FW 08/29/11 CLR N N VT-1 1-595 M1.F1.20.0025 1-MCA-FW-H127 FW 09/07/11 CLR N N VT-1 1-571 M1.F1.20.0033 1-MCA-FW-H2 FW 08/29/11 CLR N N N VT-1 1-593

                                                                                                                       .1 M1.F1.20.0036        1-MCA-FW-H122               FW  08/29/11  CLR       N          N          N     VT-1 1-596 Page 6 of 28 Printed 1/12/2012 6:33:58 AM GJU8302 v. 01/01/08                                     Cat "C" SDQA Cat     "C" McGuire 1 1/12/2012 6:31:02 AM McGuirel     1/12/20126:31:02AM                            Page 6 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M1.F1.20.0037 1-MCA-FW-H 110 FW 08/29/11 CLR N N N VT-1 1-594 M1.F1.20.0094 1-MCR-NI-788 NI 09/21/11 CLR N N N VT-11-629 M1 .F1.20.0095 1-MCR-NI-823 NI 09/21/11 CLR N N N VT-11-628 M1.F1.20.0096 1-MCR-NI-826 NI 09/20/11 CLR N N N VT-11-621 Ml.Fl.20.0097 1-MCR-NI-853 NI 09/19/11 CLR N N N VT-11-610 M1.F1.20.0099 1-MCR-NI-898 NI 09/19/11 CLR N N N VT-11-615 M1.F1.20.0121 1-MCR-NS-659 NS 09/24111 CLR N N N VT-11-639 NS 09/22/11 CLR N N N VT-11-631 M1.F1.20.0122 1-MCR-NS-679 NS 09/19/11 CLR N N N VT-1 1-620 M1.F1.20.0123 1-MCR-NS-709 M1.F1.20.0124 1-MCR-NS-714 NS 09/22/11 REC N N N VT-11-630 (A) Item #7 pipe clamp is rotated 90 deg. from sketch. (B) Bottom clamp for Item #7 does not have full thread engagement. (C) Item #10 has greater than a 1/16" gap between angle and concrete. Eng. evlauation: (A) Item #7 pipe clamp being rotated 90 deg. does not affect the function and is acceptable. (B) The clamp is tight and bolt not having fullengagement is acceptable since clamp only serves as a spacer. (C) The gap between Item #10 and wall was corrected by W/O 1949262-06. M1.F1.20.0327 1-IMCA-ND-H31 ND 08/29/11 CLR N N N VT-11-564 M1.F1.20.0398 1- MCR-VQ-541 VQ 09/20/11 CLR N N N VT-1 1-622 Printed 1/12/2012 6:33:58 AM GJU8302 v. 01/01/08 SDQA Cat "C" McGuire1 1/12/2012 6:31:02 AM Page 7 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M1 .F1.20.0590 1-MCA-NV-H43 3 NV 09/06111 CLR N N N VT-11-570 M1.F1.20.0615 1-MCA-NV-H45 9 NV 08/29/11 CLR N N N VT-11-567 M1 Fl1.20.0639 1-MCA-NV-H56 .08 NV 09/01/11 CLR N N N VT-11-561 M1 .F1.20.0782 1-MCR-NI-505 NI 09/19/11 CLR N N N VT-1 1-609 M1.F1.20.1171 1-MCR-CA-H3917 CA 09/22/11 CLR N N N VT-11-632 M1.F1.20.1177 1-MCA-CF-H20 5 CF 09/07/11 CLR N N N VT-1 1-573 Ml.Fl.20.1179 1-MCR-CF-H40 *0 CF 09/23/11 CLR N N N VT-1 1-633 1-MCA-ND-H3C ND VT-i11-600 M1.F1.20.1194 12 09/01/11 CLR N N N 1-MCA-ND-H30 ND VT-1 1-607 M1.F1.20.1195 04 09/14/11 CLR N N N VT-1 1-582 M1.F1.20.1196 1-MCA-ND-H330 ND 09/13/11 CLR N N N VT-11-560 M11F1.20.1216 1-MCA-ND-H79 ND 09/02/11 CLR N N N M1.F1.20.1226 1 -MCA-CA-H468 CA 09/14/11 CLR N N N VT-1 1-588 M1.F17.20.1263 1-MCA-NV-H95 NV 09/02/11 CLR N N N VT-1 1-559 M1.F1.20.1264 1-MCA-NV-H195 NV 09/02/11 CLR N N N VT-1 1-557 Printed 1/1212012 &33:58 AM GJUB302 v. 01/01/08 SDQA Cat "C" McGuire 1/12/2012 6:31:02 AM Page 8 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M1 .F1.20.1265 1-MCA-NV-H 197 NV 08/31/11 CLR N N N VT-11-592 M1.Fl.20.1266 1-MCA-NV-H274 NV 09/02111 CLR N N N VT-1 1-556 N N N M1.F1.20.1267 1-MCA-NV-H275 NV 09/02/11 CLR VT-1 1-604 N N N M1.F1.20.1335 1-MCA-SM-H 15 SM 09/12/11 CLR VT-1 1-578 N N N M1.F1.20.1341 1-MCA-SM-H 109 SM 09/12/11 CLR VT-1 1-577 N N N M1.F1.20.1342 1-MCA-SM-H140 SM 09/07/11 CLR VT-1 1-597 M1.F1.20.1441 1-MCA-CA-H434 CA 09114/11 CLR N N N VT-1 1-591 M1.F1.20.1442 1-MCA-CA-H464 CA 09/14/11 CLR N N N VT-1 1-590 M1.F1.20.1449 1-MCA-CA-H186 CA 09/02/11 CLR N N N VT-1 1-575 MI.F1.30.0107 1-MCA-RN-2030 RN 09/15/11 CLR N N N VT-11-603 M1.F1.30.0108 1-MCA-RN-1343 RN 09/14/11 REC N N N VT-11-583 Pipe clamp on item# 1 has loose spacer. Eng. evaluation: Since the correct 2" spacing between clamp ears is present, the loose spacers have no effect on the performance of the pipe clamp and therefore this condition is acceptable as is. No operability concern. M1.F1.30.0109 1-MCA-RN-2039 RN 09/14/11 CLR N N N VT-11-587 Printed 1/12/2012 6:33:58 AM GJU8302 v. 01/01108 SDOA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 9 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID SJ, ,stem Date Status Limited Ref RFR Comment M1 .F1.30.0110 1-MCA-RN-H978 RN 09/06/11 REC N N N VT-11-552 Rod Item #10 is not carrying load of the pipe, clamp Item #12 spacer is loose. Eng evaluation: WR#01043040 was originated to adjust rod item #10. This is not an operability concern. The spacer is not in the load path of the clamp. The loose spacer does not affect the function of the clamp and does not degrade the clamps ability to support its design loads. Mi.Fl.30.0111 1-MCA-RN-2023 RN 09/14/11 CLR N N N VT-11-606 M1.F1.30.0112 1-MCA-RN-2327 RN 09/15/11 CLR N VT-1 1-605 M1.F1.30.0113 1-MCA-RN-2081 RN 09/07/11 CLR N VT-1 1-572 M1.F1.30.0114 1-MCA-RN-1075 RN 09/15/11 CLR N VT-1 1-601 M1.11.30.0115 1-MCA-RN-1560 RN 09/02/11 CLR N VT-1 1-553 M1.F1.30.0116 1-MCA-RN-2123 RN 09/02/11 CLR N VT-1 1-555 RN M1.F1.30.0117 1-MCA-RN-1314 09/02/11 CLR N VT-1 1-558 RN M1.F1.30.0118 1-MCA-RN-2341 09/02/11 CLR N VT-1 1-554 RN M1.F1.30.0119 1-MCA-RN-2339 09/14/11 CLR N VT-1 1-589 RN M1.F1.30.0120 1-MCA-RN-H993 08/31/11 CLR N VT-1 1-599 RN M1.F1.30.0121 1-MCA-RN-1105 09/12/11 CLR N VT-1 1-576 M1.F1.30.0122 1-MCA-RN-2518 RN 09/15/11 CLR N N N VT-11-602 Printed 1/12/2012 6:33:58 AM GJU8302 v. 01/01/08 SDQA Cat "C" McGuirel 1112120126:31:02AM Page 10 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment Mt.Fl.30.0123 1-MCA-RN-2718 RN 09/14/11 REC N N N VT-11-584 A pipe cap is wedged between the top ears of the pipe clamp Item# 4. Eng. evaluation: Work Request #1043464 was written to remove the pipe cap from the pipe clamp. The cap is not being gripped by the clamp ears and therefore the cap is not affecting the function of the pipe clamp, this is not an operability concern. M1.F1.30.0124 1-MCA-RN-2335 RN 09/14/11 CLR N N N VT-11-586 M1.F1.30.0125 1-MCA-RN-2468 RN 09/07/11 CLR N N N VT-11-598 MI.F1.30.0126 1 -MCA-RN-1302 RN 09/14/11 REC N N N VT-11-585 Base plate Item #4 has greater than 1/16" gap between the plate and the concrete at southeast anchor. A review of the record copy of this hanger reveals the bearing area check requirement was waived back in 1980. After additional Engineering review of this information the hanger was determined to be acceptable with the gap beneath the baseplate. This in not an operabilty concer. M1 .Fl.30.0778 1-MCA-RN-2298 RN 09/02/11 CLR N N N VT-11-574 Ml .Fl.30.0910 1-MCA-RN-H301 RN 09/12/11 CLR N N N VT-1 1-579 M1.F1.30.1107 1-MCA-CA-H84 CA 09/06/11 CLR N N N VT-11-568 M15F1.40.0011 1SGC-LATERALS NC 10/05111 REC N N N VT-11-645 Crack like indications at rear bracket, snubber bracket to generator support ring has loose nut. W/O 01952421 / 06 written to re-tighten nut, hair line cracks are acceptable , entered into EDM-410 Structural Inspection Program for future monitoring by Engineering. No operability issue for this support. M1 .Fl.40.0074 1ELDHX-SUPPORT NV 09/23111 REC N N N VT-11-634 South East anchor has a loose nut. WO# 1952422 was written to re-torque stud and add jam nut. No operability issue since nut is designed for very low torque to allow for movement. (10 ft-lbs.) Printed 1/12/2012 6:33:58 AM GJU8302 v. 01/01/08 SDQA Cat "C" McGuirel 1/12/20126:31:02AM Page I I of 28

Inspection results for EOC-2 1 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment MI .Fl.40.0088 1WNP-SUPPORT-1 B2 WN 09/08/11 CLR N N N VT-1 1-566 Ml.Fl.40.0104 ICAPTD-SUPPORT CA 09/06/11 CLR N N N VT-1 1-569 MI.Fl.40.0112 1SWIF-SUPPORT-lA NV 09/12/11 REC N N N VT-1 1-565 Exposed anchors, nuts and washers covered with medium rust. WR# 01043112 was written to clean and coat the rusted anchors. No significant material loss (structural capacity not impaired). No operability issue. Ml .G3.1.0004 1NC1F-107 NC 09/22/11 CLR PT-1 1-037 NC 09122/11 CLR UT-11-217 (Page 1) NC 09/22/11 CLR UT-11-217 (Page 2) M1 .G3.1.0005 1NC-72-1 NC 09/22/11 CLR PT-1 1-038 NC 09/22/11 CLR UT-11-218 (Page 1) NC 09/22/11 CLR UT-1 1-218 (Page 2) MI.G3.1.0006 INC-73-1 NC 09/22/11 CLR PT-1 1-039 NC 09/22/11 CLR UT-11-219 (Page 1) NC 09/22/11 CLR UT-1 1-219 (Page 2) Ml .G6.2.0001 1PZR-MANWAY NC 09/19/11 CLR VT-11-619 M1.R1.11.0002 1NC1F-1493 NC 09/22/11 CLR UT-11-221 (Page 1) Limitation due to sweepolet configuration. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item. Printed 1/12/20126:33:59AMGJU8302v.01/01/08 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 12 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M1.R1.11.0002 1NC1F-1493 NC 09/22/11 CLR Y N Y UT-11-221 (Page 2) Limitation due to sweepolet configuration. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item. NC 09/22/11 CLR Y N Y UT-11-221 (Page 3) Limitation due to sweepolet configuration. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item. NC 09/22/11 CLR N N N UT-1 1-221 (Page 4) NC 09/22/11 CLR Y N Y UT-11-221 (Page 5) Limitation due to sweepolet configuration. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item. M1.R1.11.0003 1NC1F-1615 NC 09/22/11 CLR Y N Y UT-1 1-222 (Page 1) Limitation due to sweepolet configuration. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item. NC 09/22/11 CLR Y N Y UT-11-222 (Page 2) Limitation due to sweepolet configuration. PIP M-11-09036 was written to determine the corrective action for the limited coverage obtained for this item. NC 09/22/11 CLR Y N Y UT-1 1-222 (Page 3) Limitation due to sweepolet configuration. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item. NC 09/22/11 CLR N N N UT-11-222 (Page 4) NC 09/22/11 CLR Y N Y IUT-11-222 (Page 5) Limitation due to sweepolet configuration. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item.

                                                                                                        'C"                      McGuire 1 1/12/2012 6:31:02 AM                          Page 13 of 28 SDQA Cat Printed 1/12/2012 6:33:59 AM GJU8302 v. 01/01/08 Printed 1/12/2012 6:33:59 AMGJU8302 v. 01/01/08 SDQA   Cat "C"                       McGuirel     1/12/20126:31:02AM                         Page 13 of 28

Inspection results for EOC-21 Insp Insp Insp, Geo Summary No Component ID System Date Status Limited Ref RFR Comment MIRI1.10004 1NC1F-1613 NC 09122111 CLR Y N Y UT-1 1-223 (Page 1) Limitation due to sweepolet configuration. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item. NC 09/22/11 CLR Y N Y UT-1 1-223 (Page 2) Limitation due to sweepolet configuration. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item. NC 09122/11 CLR Y N Y UT-1 1-223 (Page 3) Limitation due to sweepolet configuration. PIP M-11-09036 was written to determine the corrective action for the limited coverage obtained for this item. NC 09122111 CLR N N N UT-11-223 (Page 4) NC 09/22/11 CLR Y N Y UT-11-223 (Page 5) Limitation due to sweepolet configuration. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item. M RR1.11. 0039 1SGC-OUTLET-W6SE NC 09/22/11 CLR Y N N UT-11-224 (Page 1) Limitation due to nozzle configuration. NC 09/22/11 CLR Y N N UT-11-224 (Page 2) Limitation due to nozzle configuration. NC 09/22/11 CLR Y N N UT-1 1-224 (Page 3) Limitation due to nozzle configuration. NC 09/22/11 CLR Y N N UT-1 1-224 (Page 4) Limitation due to nozzle configuration. NC 09/22/11 CLR Y N N UT-11-224 (Page 5) Limitation due to nozzle configuration. Printed 1/12/20126:33:59AMGJU8302v.01/01/08 SDQA Cat "C" McGuirel 1/12/20126:31:02AM Page 14 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M 1.R1. 11.0134 1NI1F19 NI 09/07/11 CLR N N N UT-11-180 M1.R1.11.0694 1NI1F249 NI 09/21/11 CLR N N N UT-11-215 (Page 1) NI 09/21/11 CLR N N N UT-11-215 (Page 2) NI 09/21/11 CLR N N N UT-11-215 (Page 3) NI 09/21/11 CLR N N N UT-11-215 (Page 4) NI 09121/11 CLR N N N UT-11-215 (Page 5) M1.RIA 1.2087 IWLI F7651 WL 10/10/11 REC N N N RT-n/a Indication is film artifact determined to be acceptable. M1.R1.11.2088 1WLP679-1 WL 10/10/11 REC N N N RT-n/a Indication is film artifact determined to be acceptable. M1..R1.11.2089 1WL1F3063 WL 10/05/11 REC N N N RT-n/a Indications are surface, and film artifact determined to be acceptable. M1.R1.11.2090 1WL1F3062 WL 10/05/11 REC N N N RT-n/a Indication is film artifact determined to be acceptable. M1.R1.11.2093 1WLI1F3060 WL 10/09/11 REC N N N RT-n/a Indications are concavity, tungsten, film artifact and sludge determined to be acceptable. M1.R1.1 1.2095 1WL1F3069 WL 10/11/11 REC N RT-n/a Indications are concavity and film artifact determined to be acceptable. Printed 1/12/2012 6:33:59 AM GJU8302 v. 01/01108 SDQA Cat "C" McGuire 1 1112/2012 6:31:02 AM Page 15 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M1.R1.11.2099 1NVP624-5 NV 09105111 CLR N N N UT-11-232 M1.R1.11.2100 1NV1F2886 NV 09/07/11 CLR Y N N UT-1 1-199 (Page 1) No scan in axial direction due to valve 1NV1 056 and pipe branch for 2" of weld length causing limitation. NV 09107/11 CLR Y N N UT-1l1-199 (Page 2) No scan in axial direction due to valve 1NV1 056 and pipe branch for 2" of weld length causing limitation. NV 09/07/11 CLR Y N N UT-1i1-199 (Page 3) No scan in axial direction due to valve 1NVi 056 and pipe branch for 2" of weld length causing limitation. M1. R 1.11.2111 1NVlFW175-31 NV 09/08/11 CLR N N N UT-1 1-182 (Page 1) NV 09/08/11 CLR N N N UT-1l1-182 (Page 2) M1.R1.11.2119 1WL1F3059 WL 10/02/11 REC N N N RT-n/a Indication is punch marks determined to be acceptable. M1.R1.11.2123 1RCHP-IN NV 09/30/11 REC Y N Y RT-n/a Indicationsn are linear and are rejectable. Indications are not service induced and determined to be fabrication type of defects. For additional information see PIP M-11-07358. PIP M-1 1-9036 was written to determine the corrective action for the limited coverage obtained for this item. M1.R1.11.2161 1NVIFW175-18 NV 09/02/11 CLR N N N UT-11-183 (Page 1) NV 09/02/11 CLR N N N UT-11-183 (Page 2) M1.Rl.11.2171 1NV1FW53-26 NV 09/26/11 CLR N N N UT-11-227 (Page 1) C" McGuire 1 l/12/20126:31:O2AM Page 16 of 28 SDQA Cat SOQA Printed 1/12/20126:33:59AMGJU8302v.01/01/08 Printed 1/12/2012 6:33:59 AMGJU8302 v. 01/01/08 Cat "C McGuirell 1/12/20126:31:02AM Page 16 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M1.R1.11.2171 1NV1FW53-26 NV 09/26/11 CLR N N N UT-1 1-227 (Page 2) NV 09/26/11 CLR N N N UT-11-227 (Page 3) NV 09/26/11 CLR N N N UT-1 1-227 (Page 4) M 1.R1. 11.2172 1NV1 FW53-30 NV 09/30/11 CLR N N N UT-11-234 (Page 1) NV 09/30/11 CLR N N N UT-11-234 (Page 2) NV 09/30/11 CLR N N N UT-1 1-234 (Page 3) NV 09130/11 CLR N N N UT-11-234 (Page 4) M1.RI.11.2297 1NV50-4 NV 09/14/11 CLR N N N UT-11-203 (Page 1) NV 09/14/11 CLR N N N UT-11-203 (Page 2) NV 09/14/11 CLR N N N UT-11-203 (Page 3) M1.R1.11.2427 1WL1F3048 WL 10/11/11 REC N N N. RT-n/a Indications are concavity, and film artifact determined to be acceptable. M1.R1.11.2428 1WL1F3049 WL 10/11/11 REC N N N RT-n/a Indications are tungsten, convexity, and concavity and film artifact determined to be acceptable. M1.R1.11.2429 1NV1FW53-33 NV 09/20/11 CL R N N N UT-11-207 (Page 1) NV 09/20/11 CL R N N N UT-1 1-207 (Page 2) NV 09/20/11 CL R N N N UT-1 1-207 (Page 3) Printed 1/12/2012 6:33:59 AM GJU8302 v. 01/01/08 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 17 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M1.R1.11.2429 1NV1FW53-33 NV 09/20/11 CLR N N N UT-1 1-207 (Page 4) M1.R1.11.2430 1NV1FW53-40 NV 09/26/11 CLR N N N UT-11-225 (Page 1) NV 09/26/11 CLR N N N UT-11-225 (Page 2) NV 09/26/11 CLR N N N UT-11-225 (Page 3) NV 09/26/11 CLR N N N UT-1 1-225 (Page 4) M1.R1.11.2431 1NV1FW53-41 NV 09/20/11 CLR N N N UT-1 1-209 (Page 1) NV 09/20/11 CLR N N N UT-11-209 (Page 2) NV 09/20/11 CLR N N N UT-11-209 (Page 3) NV 09120/11 CLR N N N UT-1 1-209 (Page 4) M1.R11.11.2434 1NV1FW15-1 NV 10/03/11 REC N N N RT-n/a Indications are tungsten, concavity, convexity and film artifact determined to be acceptable. M1.R1.16.0001 1N11F1134 NI 09/06/11 CLR N N N UT-1 1-179 (Page 1) NI 09/06/11 CLR N N N UT-1l1-179 (Page 2) MI.R1.16.0002 1N133A-1 NI 09/07111 CLR N N N UT-11-181 M1.R1.16.0003 1N11F1154 NI 09/09/11 CLR N N N UT-11-184 M1.R1.16.0004 1N132A-2 NI 09/17/11 CLR N N N UT-1 1-205 (Page 1) Printed 1/12/2012 6:33:59 AM GJU8302 v. 01101/08 SDQA Cat "C" McGuire 1/12/2012 6:31:02 AM Page 18 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Compnonent ID System Date Status Limited Ref RFR Comment M1.R1.16.0004 11\1132A.-2 NI 09/17/11 CLR N N N UT-1 1-205 (Page 2) M1.R1.16.0005 1N1F\11R /97-1 NI 09/12/11 CLR N N N UT-11-197 (Page 1) NI 09/12/11 CLR N N N UT-11-197 (Page 2) NI 09/12/11 CLR N N N UT-11-197 (Page 3) NI 09/12/11 CLR N N N UT-11-197 (Page 4) M1.R1.16.0006 1N193-4 NI 09/12/11 CLR N N N UT-11-200 Mi.R1.16.0007 1N1267 -2 NI 09/21/11 CLR N N N UT-11-213 (Page 1) NI 09/21/11 CLR N N N UT-11-213 (Page 2) M1.R1.16.0008 1N1227 -6 NI 09/21/11 CLR N N N UT-11-214 (Page 1) NI 09/21/11 CLR N N N UT-1 1-214 (Page 2) M1.R1.16.0009 1N1231- -1 NI 09/21/11 CLR Y N Y UT-11-211 (Page 1) Lift off due to configuration caused limitation. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item. NI 09/21/11 CLR Y N Y UT-1 1-211 (Page 2) Lift off due to configuration caused limitation. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item. NI 09/21/11 CLR Y N Y UT-11-211 (Page 3) Lift off due to configuration caused limitation. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item. Printed 1112/2012 6:34:00 AhA GJU8302 v. 01/01108 SDQA Cat "C" McGuire 1 111212012 6:31:02 AM Page 19 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M1.Rl.16.0009 1N1231-1 NI 09/21/11 CLR Y N Y UT-1 1-211 (Page 4) Lift off due to configuration caused limitation. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item. Ml.Rl.16.0010 1N1270B-13 NI 09/21/11 CLR N N N UT-11-212 (Page 1) NI 09/21/11 CLR N N N UT-11-212 (Page 2) NI 09/21/11 CLR N N N UT-11-212 (Page 3) NI 09/21/11 CLR N N N UT-11-212 (Page 4) M1.R1.16.0011 1NV1FW182-13 NV 08129/11 CLR Y N N UT-1l1-173 (Page 1) Throat area of Tee causing limitation. NV 08/29111 CLR Y N N IUT-11-173 (Page 2) Throat area of Tee causing limitation. NV 08/29/11 CLR Y N N UT-11-173 (Page 3) Throat area of Tee causing limitation. M1.R1.16.0012 1NV1F7900 NV 09/08/11 CLR N N N UT-11-185 (Page 1) NV 09/08/11 CLR N N N UT-11-185 (Page 2) Ml.R1.16.0013 1NV29-1 NV 09/01/11 CLR N N N UT-1 1-186 (Page 1) NV 09/01/11 . CLR N N N UT-11-186 (Page 2) NV 09/01/11 CLR N N N UT-1 1-186 (Page 3) Printed 1/12/2012 6:34:00 AM GJU8302 v. 01/01/08 SDQA Cat "C" McGuirel 1/12/20126:31:02AM Page 20 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M1.R1.16.0013 1NV29-1 NV 09/01/11 CLR N N N UT-11-186 (Page 4) M1.R1.16.0014 1NV15-2 NV 09/01/11 CLR N N N UT-11-187 (Page 1) NV 09101(11 CLR N N N UT-11-187 (Page 2) NV 09/01/11 CLR N N N UT-11-187 (Page 3) NV 09/01/11 CLR N N N UT-11-187 (Page 4) M1.R1.16.0015 1NVIF12A-12 NV 09/07/11 CLR Y N N UT-11-188 (Page 1) Limited due to tee throat. NV 09/07/11 CLR Y N N IUT-11-188 (Page 2) Limited due to tee throat. NV 09/07/11 CLR Y N N UT-1l1-188 (Page 3) Limited due to tee throat. M1.R1.16.0016 1NV1FW172-28 NV 09/02/11 CLR N N N UT-1 1-176 (Page 1) NV 09/02/11 CLR N N N UT-1 1-176 (Page 2) M1.R1.16.0017 1NVIFW175-31 NV 09/08/11 CLR N N N UT-1 1-189 (Page 1) NV 09/08/11 CLR N N N UT-11-189 (Page 2) M1.R1.16.0018 1NVlFW175-34 NV 09/02/11 CLR N N N UT-1 1-190 (Page 1) NV 09/02/11 CLR N N N UT-1 1-190 (Page 2) SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 21 of28 Printed 1/12/2012 6:34:00 AM GJU8302 1/12/2012 Printed AM GJU8302 v. 01/01/08 6:34:00

v. 01/01/08 SDQA Cat "C" McGuirel 1/12/20126:31:02AM Page 21 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M1.R1.16.0019 1NV1FW173-29 NV 09/02/11 CLR N N N UT-1 1-177 (Page 1) NV 09/02/11 CLR N N N UT-1 1-177 (Page 2) M1.R1.16.0020 1NV77-3 NV 09/07/11 CLR N N N UT-1 1-191 (Page 1) NV 09/07/11 CLR N N N UT-11-191 (Page 2) M1.R1.16.0021 1NVlFW181-25 NV 09/12/11 CLR N N N UT-11-201 (Page 1) NV 09/12/11 CLR N N N UT-1 1-201 (Page 2) NV 09112111 CLR N N N UT-11-201 (Page 3) MI .R1.16.0022 1NV1FW181-24 NV 09/12/11 CLR N N N UT-11-202 (Page 1) NV 09/12/11 CLR N N N UT-11-202 (Page 2) NV 09/12/11 CLR N N N UT-11-202 (Page 3) M1.R1.16.0024 1NV1FW175-18 NV 09/02/11 CLR N N N UT-1 1-192 (Page 1) NV 09/02/11 CLR N N N UT-11-192 (Page 2) M1 .R1.16.0025 1NVP888-1 NV 09/08/11 CLR Y N N UT-1l1-193 (Page 1) Valve 494 socket weld configuration causing limitation. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item. NV 09/08/11 CLR Y N N UT-1 1-193 (Page 2) Valve 494 socket weld configuration causing limitation. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item. Printed 1/12/2012 6:34:00 AM GJU8302 v. 01/01/08 SDQA Cat "C" McGuirel 1/12/20126:31:02AM Page 22 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M1.R1.16.0025 1NVP888-1 NV 09/08/11 CLR Y N Y UT-11-193 (Page 3) Valve 494 socket weld configuration causing limitation. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item. M1 ,Ri.16.0026 1NVIFW173-13 NV 09102111 CLR N N N UT-11-178 (Page 1) NV 09/02/11 CLR N N N UT-1 1-178 (Page 2) M1.R1.16.0027 1NV1F2112 NV 09/10/11 CLR N N N UT-11-194 (Page 1) NV 09/10/11 CLR N N N UT-11-194 (Page 2) NV 09/10/11 CLR N N N UT-1i1-194 (Page 3) MlR1.16.0028 1 NV1 F331 NV 09/10/11 CLR N N N UT-11-195 (Page 1) NV 09/10/11 CLR N N N UT-11-195 (Page 2) NV 09/10/11 CLR N N N UT-1l1-195 (Page 3) M1.R1.16.0029 1NV3-3 NV 08/29/11 CLR N N N UT-11-171 M1.R1.16.0030 1NV1 F6223 NV 08/31/11 CLR N N N UT-11-174 Ml.R1.16.0031 1NVl FW53-27 NV 09/20111 CLR Y N Y UT-11-206 (Page 1) Limitation due to valve 1NV35A configuration. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item. Printed 1/12/2012 6:34:00 AM GJU8302 v. 01/01/08 SDQA Cat "C" McGuirel 1/12/20126:31:02AM Page 23 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M1.R1.16.0031 1 NV1 FW53-27 NV 09/20/11 CLR Y N Y UT-11-206-(Page 2) Limitation due to valve 1NV35A configuration. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item. NV 09/20/11 CLR Y N Y UT-11-206 (Page 3) Limitation due to valve 1NV35A configuration. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item. NV 09/20/11 CLR Y N Y UT-1 1-206 (Page 4) Limitation due to valve 1NV35A configuration. PIP M-1 1-09036 was written to determine the corrective action for the limited coverage obtained for this item. M1.R1.16.0032 1NV1 FW53-26 NV 09/26/11 CLR N N N UT-11-228 (Page 1) NV 09/26/11 CLR N N N UT-1 1-228 (Page 2) NV 09/26/11 CLR N N N UT-11-228 (Page 3) NV 09/26/11 CLR N N N UT-1 1-228 (Page 4) M1.R1.16.0034 1 NV1 FW53-30 NV 09/30/11 CLR N N N UT-11-235 (Page 1) NV 09/30/11 CLR N N N UT-1 1-235 (Page 2) NV 09/30/11 CLR N N N UT-1 1-235 (Page 3) NV 09/30/11 CLR N N N UT-1 1-235 (Page 4) M1.R1.16.0035 1NV1 FW53-33 NV 09/20/11 CLR N N N UT-1 1-208 (Page 1) NV 09/20/11 CLR N N N UT-1 1-208 (Page 2) SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 24 of 28 Printed 1/12/2012 6:34:00 AM GJU8302 v. 01/01/08 Printed 1/12/20126:34:OOAMGJU8302v.01/01/08 SDQA Cat "C" McGuirel 1/12/20126:31:02AM Page 24 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M1.R1.16.0035 1NV1 FW53-33 NV 09/20/11 CLR N N N UT-1 1-208 (Page 3) NV 09/20/11 CLR N N N UT-1 1-208 (Page 4) Ml .Ri.16.0036 1 NV1 FW53-40 NV 09126111 CLR N N N UT-11-226 (Page 1) NV 09/26/11 CLR N N N UT-1 1-226 (Page 2) NV 09/26/11 CLR N N N UT-11-226 (Page 3) NV 09/26/11 CLR N N N UT-11-226 (Page 4) M1.R1.16.0037 1NV1 FW53-41 NV 09/20/11 CLR N N N UT-11-210 (Page 1) NV 09/20/11 CLR N N N UT-11-210 (Page 2) NV 09/20/11 CLR N N N UT-11-210 (Page 3) NV 09/20/11 CLR N N N UT-1 1-210 (Page 4) M1.R1.16.0038 1RCPSS-OUT-1 NV 09/28/11 CLR N N N UT-11-229 (Page 1) NV 09/28/11 CLR N N N UT-1 1-229 (Page 2) M1.R1.16.0040 INVl F479 NV 08/31/11 CLR Y N N UT-11-175

                                                                                                             .9" diameter metal disc TDC 1.3" D/S of weld CL causing limitation.

Ml .Ri.16.0041 1NV1 F4823 NV 08/29/11 CLR N N N UT-11-170 (Page 1) NV 08/29/11 CLR N N N UT-11-170 (Page 2) NV 08/29/11 CLR N N N UT-11-170 (Page 3) McGuire 1 1/12/2012 6:31:02 AM Page 25 of 28 01/01/081/12/2012 6:34:01 AMGJU8302 Printed 1/12/2012 6:34:01 AM GJU8302 v. Printed V. SDQA Cat SOQA Cat "C" "C" McGuirel 1/12/20126:31:02AM Page 25 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment Ml.Ri.16.0042 1 NVP624-5 NV 09/05/11 CLR N N N UT-11-233 Ml.Rl.16.0043 1NV1F2886 NV 09/07/11 CLR Y N N UT-1l1-198 (Page 1) No scan in the axial direction due to valve 1NV1 056 pipe branch for 2" of weld length causing limitation. NV 09/07/11 CLR Y N N UT-11-198 (Page 2) No scan in the axial direction due to valve 1NV1 056 pipe branch for 2" of weld length causing limitation. NV 09/07/11 CLR Y N N UT-11-198 (Page 3) No scan in the axial direction due to valve 1NV1 056 pipe branch for 2" of weld length causing limitation. M1.R1.16.0045 1NI1F249 NI 09/21/11 CLR N N N UT-11-216 (Page 1) NI 09/21/11 CLR N N N UT-11-216 (Page 2) NI 09/21/11 CLR N N N UT-11-216 (Page 3) NI 09/21/11 CLR N N N UT-11-216 (Page 4) NI 09/21/11 CLR N N N UT-11-216 (Page 5) M1.R1.16.0047 1RCHP-IN NV 09/30/11 REC Y N Y RT n/a Indications are linear and are rejectable. Indications are not service induced and determined to be fabrication type of defects. For additional information see PIP M-1 1-07358. PIP M-11-9036 was written to determine the corrective action for the limited coverage obtained for this item. M1.R1.16.0048 1WL1F7651 WL 10/10/11 REC N N N RT-n/a Indication is film artifact determined to be acceptable. Printed 1/12/2012 6:34:01 AM GJU8302 v. 01/01/08 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 26 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M1.R1.16.0049 1WLP679-1 WL 10/10/11 REC N N N RT-n/a Indication is film artifact determined to be acceptable. M1.R1.16.0050 1WL1F3063 WL 10/05/11 REC N N N RT-n/a Indications are surface, and film artifact determined to be acceptable. M1.R1.16.0051 1WL1F3062 WL 10/05/11 REC N N N RT-n/a Indication is film artifact determined to be acceptable. M1.R1.16.0052 1WL1F3059 WL 10/02/11 REC N N N RT-n/a Indication is punch marks determined to be acceptable. M1.R1.16.0053 1 NV39-1 NV 10/08/08 REC N N N RT-n/a Indication is film artifact determined to be acceptable. Note: This exam was performed under Summary Number M1.R1.11.2102 during EOC-19. No additional RT examination was performed during EOC-21. M1.R1.16.0054 1NV37-3 NV 10/11/08 REC N N N RT-n/a Indication is film artifact determined to be acceptable. Note: This exam was performed under Summary Number M1.R1.11.2103 during EOC-19. No additional RT examination was performed during EOC-21. M1 .R1.16.0055 I1NV614-1 NV 09/10111 CLR N N N UT-11-196 (Page 1) NV 09/10/11 CLR N N N UT-1 1-196 (Page 2) NV 09/10/11 CLR N N N UT-1l1-196 (Page 3) M1,R1.16.0056 1RCPA-IN-2 NV 08/29/11 CLR N N N UT-11-172 Printed 1/12/2012 6:34:01 AM GJU8302 v. 01/01/08 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 27 of 28

Inspection results for EOC-21 Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment M1.R1.16.0057 1NVlFW15-1 NV 10/03/11 REC N N N RT-n/a Indications are tungsten, concavity, convexity and film artifact determined to be acceptable. M1.RI.16.0058 1NV50-4 NV 09114111 CLR N N N UT-11-204 (Page 1) NV 09/14/11 CLR N N N UT-11-204 (Page 2) NV 09/14111 CLR N N N UT-11-204 (Page 3) Mi.R1.16.0059 1WL1F3048 WL 10/11/11 REC N N N RT-n/a Indications are concavity, and film artifact determined to be acceptable. M1.R1.16.0060 1WL1F3049 WL 10/11/11 REC N N N RT-n/a Indications are tungsten, convexity, and concavity and film artifact determined to be acceptable. M1.R1.16.0061 1WL1F3069 WL 10/11/11 REC N N N RT-n/a Indications are concavity and film artifact determined to be acceptable. M1.Rl.16.0062 1WL1F3060 WL 10/09/11 REC N N N RT-n/a Indications are concavity, tungsten, film artifact and sludge determined to be acceptable. Printed 1112/2012 6:34:01 AM GJU8302 v. 01/01/08 SDQA Cat "C" McGuire 1 1/12/2012 6:31:02 AM Page 28 of 28

5.0 Owner's Report for Repair/ Replacement Activities As required by the applicable code, records of Class 1 and Class 2 Repair and Replacement work is included on NIS-2 forms in this section. No items were determined to have work performed outside this report period. The NIS-2 forms included in this section were completed for work performed during this report period. The individual work request documents and manufacturers' data reports are on file at McGuire Nuclear Station. 5.1 Class 1 and 2 PreserviceExaminations As required by the applicable code, Preservice Inspection (PSI) Examinations were performed on ISI Class 1 and 2 items during this report period. All Class 1 and 2 PSI examination data listed below is on file in the McGuire Nuclear Station QA Vault. Also included in this listing are the Class 3 PSI Examinations performed during this report period. See Attachment A listing for Repair and Replacements for McGuire 1 EOC-21. Outage 7/EOC 21 Refueling Outage Report Page 1 of 1 McGuire Unit 1 Revision 0 Section 5 January 12, 2012

Work Order# Task -Class Description of work I Attachment A Page 1 of 5 575415 1 IB Replaced snubber on hanger 1MCA-FW-148 575416 1 B Replaced snubber on hanger 1MCA-FW-149 588431 1 B Replaced snubber on hanger 1MCA-NI-12 588436 1 B Replaced snubber on hanger 1MCA-ND-256 5884376 1 B Replaced snubbers and there bolting material on hanger 1MCA-ND-255 588439 1 B Replaced snubbers and there bolting material on hanger 1MCA-ND-254 588444 1 B Replaced snubber on hanger 1MCA-ND-248 588445 1 B Replaced snubber on hanger 1MCA-ND-247 588463 1 B Replaced snubbers on hanger 1-MCA-FW-116 591155 1 B Replaced snubber on hanger 1MC-1683-NV-60 R3 591166 1 B Replaced snubber on hanger 1MCA-ND-179 _ 591167j 1 B Replaced snubber on hanger 1MCA-ND-2_89 - 591168 1 B Replaced snubber and it's bolting material on hanger 1MCA-ND-296 591169 1 B !Replaced snubber on hanger IMCA-ND-315 591170 1 BIReplaced B snubber and it's bolting material on hanger 1MCA-NV-374 591170 - 12 B Replaced snubber and it's bolting material on hanger 1MCA-NV-374j 591172  ! .. 1 .. __ B- Replaced snubber and it's bolting material on hanger 1MCA-NV-5555 591173 1 j B Replaced snubber on hanger 1MCA-NV-5556 - 591192  ! 1 B Replaced snubber and it's bolting material on hanger 1MCA-NS-91 591194 . 1 B Replaced snubbers and there bolting material on hanger 1MCA-NS-98 591213 1 B Replaced snubber on hanger 1MCA-VQ-10 591339 1 B Replaced snubber on hanger 1MCA-ND-304 591340 1 B Replaced snubber and bolting material on hanger 1MCA-ND-250 591378 1 B Replaced snubber on hanger 1MCA-BB-410 591379 1 - B Replaced snubber on hanger 1MCA-BB-410 591386 1 B Replaced snubber and bolting material on hanger 1MCA-NI-253 591387 1 B Replaced snubber and bolting material on hanger 1MCA-NI-255 591390 1 B Replaced snubber and bolting material on hanger 1MCA-NS-88 591420 1 B Replaced snubber on hanger 1MCA-SM-188 591421 _ 1 B Replaced snubber on hanger 1MCA-SM-192 591423 1 B Replaced snubber on hanger 1MCA-SM-200 591484 1 B IReplaced snubber on hanger 1MC-1683-NV-01-R8A

591489 1 B Replaced snubber on hanger 1MCA-CF-152 I_ 591530 1 B Replaced snubbers and their bolting material on hanger IMCA-NS-85B 591544 1 B Replaced snubbers on hanger 1MCA-SM-69 I 591553 1 B Replaced snubber on hanger 1MCA-SM-19 591553 12 B Replaced snubber on hanger 1MCA-SM-19 _ 592066 F 31 B Replaced bolting material on clamp of hanger 1MCA-BB-402 592066 35 B Cut out and replaced valve 1BB413 592067 1 B Cut out and replaced valve 1BB533 592068 1 B Cut out and replaced valve 1BB6 1784845 4 B Replaced disc in valve 1NC57 1794709 1 B Replaced snubber on hanger 1MCR-VQ-514 1794711 1 1 B Replace snubber and it's bolting material on hanger 1MCR-VQ-506 1794735 1 B Replaced snubber and it's bolting material on hanger 1MCR-S-NI-100-04-Y 1794752 1 B Replaced snubber on hanger 1MCR-NV-1214 1794755 1794757 11_ B B Replaced Replaced snubber snubber on andhanger 1MCR-NV-1213 it's bolting material on hanger 1MCR-NV-1206 1794773 1 B Replaced snubber and it's bolting material on hanger 1MCR-NV-1201 1794774 1 B Replaced snubber on hanger 1MCR-NV-1043 1794895 1 B iReplaced snubber and it's bolting material on hanger 1MCR-NV-581 1794896 1 B Replaced snubber on hanger 1MCR-NV-545 1794903 1 -1 B Replaced snubber on hanger 1MCA-CA-411 1794904 1 B Replaced snubber and it's bolting material on hanger 1MCA-NV-306 1794905 1 1 B Replaced snubber and it's bolting material on hanger 1MCA-ND-272 1794907 1 - B Replaced snubber on hanger 1MC-1683-NV.04-R33 _ 1794908 1 B Replaced snubber on hanger 1MC-1683-NV.01-R16 17949i .1 . B Replaced snubber on hanger 1MCA-SM-104 F 1794913 1 . B IReplaced snubber on hanger 1MCA-ND-286I 1794915 -1 B Replaced snubber and it's bolting material on hanger 1MCA-ND-298 1794916 1 B Replaced snubber on hanger 1MCA-ND-290 I 1794917 1 B Replaced snubber on hanger 1MCA-ND-287 1794919 1 1 1 B Replaced snubber on hanger 1MCA-ND-275 1794920 j 1 B Replaced snubber on hanger 1MCA-ND-181 1794925 -- 1 B Replaced snubber and it's bolting material on hanger 1MCA-ND-270 17949351 1 B Replaced snubber on hanger 1MCA-SM-182 ___

1794939 1 B Replaced snubber on hanger 1MCA-ND-273 1794941 1 B Replaced snubber on hanger 1MCA-CF-201 1794942 1 B Replaced snubber on hanger 1MCA-CF-201 1794967 1  ! B Replaced snubber and it's bolting material on hanger 1MCA-NV-498 1794990 1 bBB Replaced snubber on hanger 1MCA-ND-271 1810883 1 A Seal weld cover on valve 1NI19 1810884 1 A Seal weld cover on valve 1NI17 1810887 1 A Seal weld cover on valve 1N1347 1857897 i 1 B Replaced disc in valve 1NS36 1864150 23 B Insalled piping per EC99750 1867772 3 B Replaced disc in valve 1NS64 1878522 20 B Replaced pipe clamp on hanger 1MCA-ND-333 due to operator change out on valve 1ND15 1892748 1 B Replaced plug assembly in valve iSV-1 AB 1 1897294 12 B Replaced bolting in flange at valve 1NVFE5330 1905977 2 B Replaced relief valve INV155 1911887 1 B Replaced snubber on hanger 1MCA-NV-435 1917396 13 B Replaced bolting material on excess letdown heat exchanger 1918405 1 B Replaced snubber on hanger 1MCA-ND-327 I 1919132 18 B Replaced hanger 1MCR-NS-767 with new support per EC101539 1919840 1 B Replaced disc in valve 1V1149 1919840 9 B Cut out and replaced valve 1V1149 per EC103658 1919897 1 B Replaced valve 1NV220 and it's bolting material 1920006 1 __BB Replaced rear pivot mount on hanger 1MCR-NI-702 1922133 1 B Replaced snubber on hanger 1MCR-BB-585 1922134 1 B Replaced snubber on hanger 1MCR-NV-548 1922135 1 B Replaced snubber on hanger 1MCR-NV-1006 1922137 1 *_ B Replaced snubber and it's bolting material on hanger 1MCR-S-NV-100-02-S 1922138 1 B Replaced snubber on hanger 1MCR-S-NF-100-01-H 1922139 1 B Replaced snubber on hanger 1MCR-NV-972 K 1922155 1 B Repla snubber on hanger IMCR-CF-404.... 1922156 1 B Replaced snubber on hanger 1MCR-CF-403 _ 1922157 1 B Replaced snubber on hanger 1MCR-CF-402 1922362 1 B Replaced snubber on hanger 1MCA-SM-11 1922368 1 B Replaced snubber and it's bolting material on hanger 1MCA-CA-432

1922384 1 B Replaced snubber and it's bolting material on hanger 1MCR-NV-943 1922396 1 B Replaced snubbers on hanger 1MCA-SM-103 1922401 j 1 B Replaced snubbers on hanger 1MCA-SM-75 __1 s 1922405 1922412 1 B B Replaced Replaced snubber snubber on on hanger hanger 1MCR-NV-966 IMCA-CF-157 1922414 1 B Replaced snubbers on hanger 1MCA-SM-108 1922418 1 B Replaced snubber on hanger 1MCR-BB-663 1922422 F 1 B Replaced snubber on hanger 1MCR-NV-1048 1922423 1 A Replaced snubber on hanger 1MCR-NC-574 1922427 1 B Replaced snubber on hanger 1MC-FW-121 1922428 1 B Replaced snubbers on hanger 1MCA-ND-281 1922433 1 B Replaced snubber on hanger 1MCA-ND-297 1922445 1 B Replaced snubber on hanger 1MCA-FW-118 1922446 1 B Replaced snubber on hanger 1MCA-FW-120 1922447 1 B Replaced snubber on hanger 1MCA-FW-126 1922449 - 1 B Replaced snubbers on hanger 1MCA-FW-160 1922451 1 B Replaced snubber and it's bolting material on hanger 1MCA-NV-471 1922452 1 B Replaced snubber and it's bolting material on hanger 1MCA-NV-5522 1922553 1 B Replaced snubber and it's bolting material on hanger 1MCA-NV-396 1922571 1 B Replaced snubber on hanger 1MCA-SM-185 1922572 1 B Replaced snubber on hanger 1MCA-SM-209 1930950 8 B Replaced bonnet on valve 1NV498 per EC102955 1930951 14 B Modified hanger 1MCR-BB-501 per EC100651 1930951 18 B Modified hanger 1MCR-BB-507 per EC100651 1948066 9 B Replaced bolting in flange 1NVFE5300 I 1952310 49 B Replaced snubber on hanger 1MCA-NV-5609 1952541 7 B Reworked hanger 1MCR-NV-11901 1956492 3 B Replaced bolting material on penetration M461 1956861 56 B Replaced snubber on hanger 1MCA-CF-173 1957052 2 -B Replaced control valve in Lisege Snubber (SG-D) 1957177 .A 8 Replaced valve INCI 2002923 1- A Seal welded body to bonnet on valve 1NV810 2002923 6 LA Reworked hanger 1MCR-NV-848 2004055 1 A Base metal repair on piping at hanger 1MCR-NV-1059

2004926 21 B Replaced WL piping per EC106925 2005281 15 B Installed hanger 1MCR-WL-785 per EC106925 2005296 1 A Replaced snubber on hanger 1MCR-NC-769

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

i. Owner .. Duke Elnýergy-C arol in _as LI LC . . .. .
                                                                      ----------- .    .~---..    -                  Date 8/24/2010 526 South Church Street. ChNarloteC, 2820291-                                                      Sheet     I        of' 2 Address
2. Plant McGui-re Nuclear_Station Unit t Name 12700 Hagqs Fer_ Road, Huntersville,&NCQ28078 575415-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by k LL-.

Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street. Charlotteig N 8201- 1006 _ Address Expiration Date: N/A

4. Identification of System FW - Refueling Water
5. (a) Applicable Construction Code ASME 1I] 19 71: Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed[ition with the 1999 and 2000 Addenda (c) Applicable Section XL Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-FW-148 Duke Energy .19293 N/A N/A N/A Removed No IMCA-FW-148 *Duke Energy 37211 N/A N/A N/A Installed No

7. Description of Work Rer flacedCgmponent/Part/Appurtenance Additional Description relplaced snubber on hanger I MCA-FW- 148
8. Tests Conducted: Hydrostatic F" Pneumatic I" Nominal Operation Pressure FT Exempt F Other I- Pressure* PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 24 in. (nominal) System Class: ASMEClass2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1570-01.00 Support/Restraint Sketch/Drawing No(s).: IMCA-FW- 148 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRF-FWA-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist " Date August 24 - 20 10 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

 *--[ .. z../"--O...(...to 43"0/O-                          ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspectio JF Swan

  • Commissions NC 1524, N-I National Board, State, Province, and Endorsements Date 20-1D

FORM NIS-2 OWNER'S REPORT FC)R REPAIR/REPLACEMENT ACTIVITY As Required by the Provisio ns of the ASME Code Section XI

1. Owner . Duke Ener C jas LLC .

Date 8/24/2010 526 South Church Street, NCharlCtte,_N_28_201 Sheet I of 2 Address

2. Plant McGuire _Nuclear Station Unit .1 Name 12700-Hagers_ Fey oa Hunters.ille. NC.28078 575416-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke EnergyC-arolinas, LLC . N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street _Charlotte NC 28201-1006 Address Expiration Date: N/A

4. Identification of System FW - Refueling Water
5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1.998 Edlition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-FW-149 Duke Energy 19288 N/A N/A N/A Removed No IMCA-FW-149 Duke Energy 21739 N/A N/A N/A Installed No

7. Description of Work Re1 ýatcedpCromponen-tPa .rt/Appurtenance Additional Description re placed snubber on hanger IMCA-FW- 149
8. Tests Conducted: Hydrostatic I Pneumatic FT Nominal Operation Pressure rI Exempt F Other 17 Pressure PSI Test Temp. _

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 24 in. (nominal) System Class: ASME Class_2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1570-01.00 Support/Restraint Sketch/Drawing No(s).: IMCA-FW- 149 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRF-FWA-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist - Date August 24 - 2010 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

                        -                  2'-.-"       /o,          and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither t0 Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspectio JF Swan /*/ "'.- a .-- - Commissions NC1524, N-I Inspector's SSignatur,ý r/ National Board, State, Province, and Endorsements 20 *1

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

1. Owner fluke Fneroy Carolina_* L[ LC Date .6/22/2011 526 South Church Street. Charlotte, NC, 28201 A *J ....

Sheet 1 of 12 Aduress

2. Plant McGuire Nuclear Station Unit I Name 12700 Ha1aers Ferry Road. Huntersville. NC 28078 ý588431-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: iN/A
4. Identification of System :NI - Safety Injection
5. (a) Applicable Construction Code ASME III 1971F Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) :N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-NI- 12 Duke Energy .21291 .N/A N/A N/A Removed No

.IMCA-NI-12                             Energy E.Duke                                      38394                                             N/A                                :N/A                             .     .. N/A     . I!s....

t

                                                                   ...~ ....~~ l~                   ~         11    ~ i!~ii12 ~ ~ ~ .......                 2~ 11!1~.. ~~~~~. ...                    ..... .....
                      . .. . I . .  .   .. . .. .   ... . . . .  .  .    . . .. .  " .. . ..     ..   .. .. .. . . . .  . . . ....:J : .... .. .... . . . .. ". . ... . h...   .  ....              ...     .    ..  . . . ..

12

7. Description of Work Replaced Component Part/Appurtenance Additional Description Replaced snubber or ihanger 1MCA-NI- 1MCA-NI- 12 ahanger
8. Tests Conducted: Hydrostatic F Pneumatic Nominal Operation Pressure r . Exempt F.. Other r Pressure ______PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2. of .2 Component Line Size: 6 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: .MCFD- 1562-03.00 Support/Restraint Sketch/Drawing No(s).: IMCA-NI-12 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NIA-00I Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FLGrass, Quality Assurance Technical Specialist Date :June 22 , 201L Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolhna .. "and employed by !Hartford Steam Boiler Inspection and Insurance Company of iConnecticut have inspected the components described in this Owner's Report during the period

 .-. 6..z".2-   -/'       '.f/L to              _                    and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither the Inspe or nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. JF Swan X, 0- j, j.Commissions NB 11473-NC1524, N-I D. ....

                     -Inspector's Signature                                                         National Board, State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner SDuke Energy Carolinas*,LLC Date 8/30/2010 526 South Church Stree. Charlotte,_C_ 28201 .. Sheet 1 of. 2 Address
2. Plant McGuire Nuclear Station Unit I Name 12U70_Hag-e!rs Ferry - Huqntersvilie, NC 28078 588436-01 Address Work Order# (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by DukeEnergyCaroinas LLC .

Name Type Code Symbol Stamp: Authorization No.: 526 South Church Street, Charlotte, NC 2820 1-1006 Address Expiration Date: N/A

4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME Ill 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 199.8 Edition with thbe 19.99..a-nd 2000__Add-end-a_

(c) Applicable Section XI Code Case(s) N/A

6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-ND-256 Duke Energy 15851 N/A !N/A :N/A Removed No IMCA-ND-256 Duke Energy 36705 N/A N/A N/A Installed No

7. Description of Work Re.placed Component/Part/Apprtenaince Additional Description re placed snubber on hanger IMCA-ND-256.
8. Tests Conducted: Hydrostatic - Pneumatic r- Nominal Operation Pressure FT Exempt F Other F Pressure : PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 12 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1563-01.00 Support/Restraint Sketch/Drawing No(s).: MCA-ND-256 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-FWA-004 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist , Date August 30 ,20 10 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period _~"~/~r~ŽlZJQ to &*'--- / /. ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Own I's Report. Furthermore, neither t Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro ?/or connected with this inspectia JF Swan .... w 1.k CoO,_7i't-,Z.. Commissions NC1524, N-1 Inspector's signature-' National Board, State, Province, and Endorsements ot( iZ I 16r-ý 20.L-Cý/

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner 1T~nk~ Pner~'v Carn1~i~a~ L Ti LC Date 9/19/201 1 Duke P-nerpv Carolinas 526 South Church Street. (Charlotte, NC. 28201 Sheet :I of 2 A~id~
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville. NC 28078 588437-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street. Charlotte. NC 28201-1006 KrT A Address Expiration Date:
4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME Hi 1971. Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

'IMCA-ND-255 Duke Energy 18012 N/A N/A N/A Removed No IMCA-ND-255 Duke Energy .37823 N/A N/A Installed NNA No 1lMCA-ND-255 'Duke Energy .20854 N/A N/A N/A Removed No IMCA-ND-255 Duke Energy 37830 N/A .. N/A N/A Installed No

7. Description of Work Retelaced Coms onent/Part/Applurtenance Additional Description R eplaced snubbers and there bolting material on hanger I MCA-ND-255
8. Tests Conducted: Hydrostatic T Pneumatic rT Nominal Operation Pressure F Exempt F Other F Pressure' PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 12 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD3-1563-01.00 Support/Restraint Sketch/Drawing No(s).: IMCA-ND-255 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist kZ4v4 ft - Date September 19 ,2011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of I Connecticut__
                  .. /L.z.L..,to have inspected the components described in this Owner's Report during the period and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the spector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro or connected with this inspection. iJF Swan * " Commissions :NBI 1473-NC 1524, N-I Inspector's Signature/ "National Board, State, Province, and Endorsements Dald ' al()

                               *7-20-LI

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions oethe ASME Code Section XI

1. Owrer Duke Energy Carolinas. LI C Date WI*9"201.

5~niith Chtwr~h Street ICharlotte. NC. 28201 Sheet L of 526 South Q11-h AAA- Street-

2. Plant McGuire Nuclear Station Name Unit .

12700 Haters Ferry Road, Huntersville, NC 28078 :588439-01 Address Work Order # (or Repair/Replacern'ent Organization P.O. No., Job No., etc.)

3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte, NC 2820 1-10(06 :XI Address Expiration Date: ,*,'L
4. Identification of System D-ReiulHaRmol
5. (a) Applicable Construction Code ASME 111 191.2 Edition, ;Summer and Winter - Addenda, ,N/A . Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) .N/A
6. Identification of Comn onents Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built . Installed (Yes or No)

I MCA ND254 . Duke Energy .14937 N/A . NIA N/A Removed 1MCA-ND-254 Duke Energy 1 7827..  !.N/A 'N/A .iN/ , Installed No

.MCA-ND-254. .                       Duke Energy                                    149437                       NIA                      VN/A                                        NA    I      Removed IMCA-ND-254                                       -.-..                   .        3761                         N/AN/AN/A                                                                         Installed
7. Description of Work Replaced Component/Part/Apourtenance Additional Description :Replaced snubbers and there bolting material on hanger IMCA-ND-254
8. Tests Conducted: Hydrostatic r_ Pneumatic r7 Nominal Operation Pressure I1' Exempt .F Other F Pressure . PSI Test Temp.. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIRfEPLACEMENT ACIWITY As Required by the Provisions orthe ASM* Code Section X1

                                                                                                                                                                                                          * ~,,"""
                                                                                                                                                                                                               ~      ~   V -- t
9. Remarks (Should Include the Following Information, as Applicable): Sheet of 1._j Component Line Size: '12 . . . (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: fN/A "". .... --"".........

Flow Diagram No(s).: 1MCFD-1563-01.00 Support/Restraint Sketch/Drawing No(s).: iMCAND254 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: S... .. ... ..... ... ......... Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF CODPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. iN1A Expiration Date 'N/A I SigndFL Grass, Quality Assurance Owner or Owner's Technical Specialist Designee. Title jDate September 19 20611 CERTIFICATE OF INSERVICE.INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Insptatct..rs d the S or Provc f

   .NorthCarolina...............                                                          and employed by Hartford Steam Boiler Inspection and Insurance Company                                                                  of
Connecticut have inspected the components described in this Owner's Report during the period "to - and state that tO the best of my knowledge and belief, the Owner has perforned exam-iinations and taken corrective measures describedin this Owner's Report in accor ance with the requirements ofthe ASME Code, Section X1.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither aeInspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from fr connected with this inspecti 1F Swan ..... .,commissions CI*j-,,,- !NBI1473-NC1524, N-Il

                     /

nsl~ctor's Signalture T National Board, State, Province, and Endorsemients Datr/20LL

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner ... DukeEnergy Carol inas, LLC . ... .. .. . . .... .... . Date :8/24/2010 526_South Church Street Charloe.. Sheet ! of 2 Address
2. Plant McGuire _Nuclear Station Unit .I Name 127O0 HagersFerryoadH ptersville, NC 28Q78 588444-01 Address 588444-01 Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Car9l.inas,._LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street. Charlotte. NC 28201-1006 ......

Expiration Date: N/A Address

4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME 11l 19 71 " Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification Af Cnmn *nent5 Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

SI MCA-ND-248 Duke Energy 14872 N/A ;N/A N/A Removed No 1MCA-ND-248 Duke Energy 20754 N/A N/A N/A Installed No

7. Description of Work pl-ace(d Co-rnpo-en-tP-aq(Ap-pu-e-nanceg Additional Description ret )1laced snubber on hanger IMCA-ND-248
8. Tests Conducted: Hydrostatic F Pneumatic F- Nominal Operation Pressure IF Exempt P Other r" Pressure PSI Test Temp. __

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 14 in. (nominal) System Class: ASMEICass 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 156 1-0 1.00 Support/Restraint Sketch/Drawing No(s).: IMCA-ND-248 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-FWA-006 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date August 24 ,20210 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut *have inspected the components described in this Owner's Report during the period 0-1-S 1 .to- and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither the Insp ctor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. JF Swan -. lnspector's Signature F /National

                                                            -Commissions                                                NC 1524, N-I Board, State, Province, and Endorsements Date~j                 >                                 20:_!O

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Dluke Ener~v Carolinas. LI LC Date 6/22/201i.

Duke Energv Carolinas. L 526 South Church Street. Charlotte NC, 28201 Sheet I off 2 Adoress

2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 W588445-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: :N/A Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 "'MT A Address Expiration Date: INIl
4. Identification of System !ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME III 1971i Edition, Summer and Winter Addenda, iN/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section X1 Code Case(s) :N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name ofManufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1IMCA-ND-247 Duke Energy 21281 NAN/A IN/A Removed No 1MCA-ND-247 :Duke Energy 137051 N/A N/A N/A Installed No
                              . ..           ..             ;1 . . . .     . .. ... ..... ... ... .... . ...    . ... .. . . . . . . .. . ..... .. . ... . ...... .  . ... .. . ....           . . ..     .. .. ...
                                                                                       . . . ..      .    ~~..
                                                                                                             . ..... .. . ... ...  ..             . ..                                .     .. l   .    .  .
7. Description of Work Replaced Component/Part/A urenc Additional Description Replaced snubber ot i hanger I MCA-ND-247
8. Tests Conducted: Hydrostatic F- Pneumatic [- Nominal Operation Pressure.F Exempt P Other F7 Pressure _ _PSI Test Temp..

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet of Component Line Size: 14 - in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1561-01.00 Support/Restraint Sketch/Drawing No(s).: IMCA-ND-247 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-FWA-006 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date June 22 ,2011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina .and employed by Hartford Steam Boiler Inspection and Insurance Company of

 'Connecticut                                                                   have inspected the components described in this Owner's Report during the period k     -L/2.to                               ",                     and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his em poyer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspec nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection.

  .JF Swan     6     .                                                                     ..       CommissionsNB I1473-NCI524, N-I
          ,,          Inspector's Signature           .'ýv                                         National Board, State, Province, and Endorsements I

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTMTY As Required by the Provisions of the ASME Code Section XI 1.Owner Duke Enery Carolinas, LI LC Date .7/19/2011.. 526 ~A1,th Ch~irch ~treet~ ICharlotte, NC, 28201 Sheet I of 2 526 Sou Church A A,1 Street

2. Plant McGuire Nuclear Station Unit 1 Name 12700 Haier. Ferry Road_ Huntersville. NC 28078 588463-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: :N/A Authorization No.: N/A 526 South Church Street, Charlotte, NC 2820 1-1006 Address Expiration Date: N/A
4. Identification of System FW - Refueling Water
5. (a) Applicable Construction Code ASME III 1927 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCA-FW- 116 Duke Energy '20443 N/A Removed IMCA-FW-116 ;Duke Energy 38080 NA/N/A Installed No 1MCA-FW- 116 'Duke Energy 20445 IN/A 'N/A N/A Removed No IMCA-FW-1 16 Duke Energy 38083 .N/A N/A N/A Installed No
7. Description of Work Ret )laced Component/Part/Appurtenance Additional Description Reeplaced snubbers on hanger I MCA- FW-I 16
8. Tests Conducted: Hydrostatic F Pneumatic F Nominal Operation Pressure F Exempt F Other F Pressure PSI Test Temp. ___°F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2_ . of ý Component Line Size: 8 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1 554-03.01 Support/Restraint Sketch/Drawing No(s).: IMCA-FW-l116 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date :N/A Signed FL Grass, Quality Assurance Technical Specialist Date July 19 ,20 1I Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

North Carolina .and employed by Hartford Steam Boiler Inspection and Insurance Company of
ýConnecticut                                                                   have inspected unttd the components described in this Owner's Report durinar the period to.

7// 7 a / -/Z ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Ins ptor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from oconnected with this inspection. IF Swan 10 Z- Cmiomm*ifcn..NB 11473-NC1524, N-I National Board, State, Province, and Endorsements uiII12 Inspector's Signature Dat*e . 7 l C " = J4 20J~ 21

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke EneryCarolinas_ . Date 10/19/2010 526 SouthChurch Street. Charlotte..NC,.2820_ . . .. .. .. Sheet 1 of 2 Address
2. Plant McGuire Nuclear Station Unit I Name 127.0Q H gers Fe rrv._oad, utersvil,.NC 28078 '591 155-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carol'nas, Lf C Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street, CharlotteNC 28201-1006 Address Expiration Date:

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME I1 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity ..t998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMC-1683-NV-60R3 Duke Energy 21809 N/A N/A N/A Removed No IMC-1683-NV-60R3 Duke Energy 36699 N/A N/A N/A Installed No

7. Description of Work Rqp!lace omtponent/Part/Appurtenance Additional Description re placed snubber on hanger IMC- 1683-NV-60R3
8. Tests Conducted: Hydrostatic F" Pneumatic r' Nominal Operation Pressure F Exempt F- Other I- Pressure __ PSI Test Temp. _ °OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): 2 of 2 .

Sheet Component Line Size: 11/2 in. (nominal) System Class: ASME.Class_2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MVFD-1554-02.00 Support/Restraint Sketch/Drawing No(s).: IMC- 1683-NV-60R3 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date October 19 ,20 10.. Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period 7-10 to / 2 t . D" " /.. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Jspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fron/or connected with this inspection. JF Swan V . -'* Inspector's Signatur

                                                                               -               Commissions NC1524, N-I National Board, State, Province, and Endorsements Date(/          0     - a,0                             20oP

FORM N1S-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner Duike- Energy -Caroli.nas, LL .. . -C. .. .... . .. .. Date 3/2/2011 526 SouthChurch SCtreet,c h r-NC282-. ------. . . . . Sheet 1 of'2 Address
2. Plant McGuire Nuclear Statioon. Unit .1 Name 12700 Hap-ers; et rrv Road,.Huntersvi_!eJ.NC 28078 '591 166-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke EnergyCarolinas .. .

Type Code Symbol Stamp: N/A Name Authnrizatinn Nno N/A 526 South Church Street. Charlotte. NC 28201-1006 N/A Address Expiration Date: N/A

4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME ill 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1.998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-ND-179 Duke Energy 14886 N/A N/A N/A Removed No IMCA-ND-179 Duke Energy 37598 N/A N/A N/A Installed NQ

7. Description of Work R epl;
                                         --aci~d Com..po nen t/Part/Appurtenance Additional Description               re placed snubber on hanger I MCA-ND-179
8. Tests Conducted: Hydrostatic FT Pneumatic r" Nominal Operation Pressure FT Exempt F Other r. Pressure __PSI Test Temp. _ IF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 3 *in.(nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 156 1-01.OO Support/Restraint Sketch/Drawing No(s).: I MCA-ND- 179 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date March 2 ,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina , , ,14,, Hartford Steam Boiler Inspection and Insurance Company 4r ave ý uy eted th cYdn d t pi Connecticut have inspected the components described in this Owner's Report during the period L/ O 3 - /t and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's keport. Furthermore, neither the Insp ctor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from orbnnected with this inspection. JF Swan Commissions NC1524, N-I

       &0,~                                          'p Inspector's Signature                                                     National Board, State, Province, and Endorsements Date                                                 ,20I

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Enrgy.C)arolin as,_L S................................................... ---- Date 8/10/2010 526 South Church Street,_Charlotte. NC. 28201.Sheet 1 of 2 Address
2. Plant Mc.Gui-re Nuclear....

Station Unit I Name 12700 HaersEerry__Qad,- Huntersyvi~le, NC 28078 *591167-01 Address Work Order 9 (or Repair/Replacement Organization P.O. No., Job No., etc.)

3. Work Performed by DukeEnergy CarolinasLLC Type Code Symbol Stamp: N/A Name Authorization No.: N/A 526 South Church Street,. Charlotte, NC 28201-106 Address Expiration Date:
4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-ND-289 Duke Energy :00165 N/A N/A N/A Removed No

20502 N/A N/A Installed No IMCA-ND-289 Duke Energy 252N/A N/A-----
7. Description of Work R~e. Al aced Component/ParAppurtenance Additional Description re placed snubber on hanger I MCA-ND-289
8. Tests Conducted: Hydrostatic F Pneumatic r" Nominal Operation Pressure F Exempt F7 Other F Pressure PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 8 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1561-0 1.00 Support/Restraint Sketch/Drawing No(s).: I MCA-ND-289 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NDA Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date August 10 ,20 10 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period Lm - S. / 0 to t / . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither the pector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. F Swan --.

                                                                                        *Commissions                    NC1524, N-I SInspector's Signature                                                        National Board, State, Province, and Endorsements Dýe                                                        0-                             ,

FORM NIS-2 OWNER'S REPORT FOR REPA[IRREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy CarolinasLLC Date 8/19/2010 526 South Church Street, Charlotte. NC, 28201 Sheet 1 of 2 Address
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road HuntersvilleiNC 28078 .591168-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No.. etc.)
3. Work Performed by Duke Energy Carolinas, LLC.........

Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street CharoQtte,_NC 28201-1006 Address Expiration Date: N/A

4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME III 1971 Edition, .Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed[ition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Comp)onents Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-ND-296 Duke Energy 14813 N/A .N/A N/A Removed No IMCA-ND-296 .Duke Energy 20533 N/A N'N/A N/A Installed No

                                       . .. ....  . ..    ..   ... ~~....                      . . . .       .     . . . . .r.  ~~... 7 7. .  .        .    .   ..        .  .
7. Description of Work Replaced Component Part/Appurtenance Additional Description replaced snubber an Ibolting material on hanger IMCA-ND-296
8. Tests Conducted: Hydrostatic F Pneumatic IF Nominal Operation Pressure F Exempt F . Other F Pressure PSI Test Temp. OF Description (Optional): _

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X!

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 8 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: .MCFD-156I-0l .00 Support/Restraint Sketch/Drawing No(s).: IMCA-ND-296 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NDA-002 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist \ -'*1L Date August, 19 _ 20 10 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

  • _ o F./'-? ZC/!, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the I ector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from oconnected with this inspection.

 .JFSwan                                                                                           Commissions NC 1524, N-I Inspector's Signature S                                                                            National Board, State, Province, and Endorsements Date                                                  ,20ý      5

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions ofthe ASME Code Section X1

1. Owner Duke Energy Carolinas LLC Date 8/24/2010 526 South Church Street Charlotte, NC, 28201 Sheet I of 2 Address
2. Plant McGiuireNLuclear Station Unit 1 Name 12700 _Hagas Fey RoadaHuntersville, NC 28078 .591169-01 Address Work Order # (or Repair(Replacement Organization P.O. No., lob No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street Charlotte NC 28201-1006 Address Expiration Date: N/A
4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section X1 used for Repair/Replacement Activity 998. Ed ition with the 1999 and 2000_Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-ND-3.15 Duke Energy 20555 N/A N/A "N/A Removed No IMCA-ND-315 Duke Energy .21063 N/A N/A N/A Installed No

7. Description of Work Rep laced Component/Part/Appurtenance Additional Description retplaced snubber on hanger IMCA-ND-3 15
8. Tests Conducted: Hydrostatic F Pneumatic F" Nominal Operation Pressure F' Exempt F' Other F . Pressure __PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 2 in. (nominal) System Class: ASME__Class_2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1561-01.00 Support/Restraint Sketch/Drawing No(s).: IMCA-ND-315 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NVV-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist "f./* __'-e..- Date August 24 ,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

  ?.-    9*..S-/I      Q         to         " *--.sŽ.zi        i,    and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Own 's Report. Furthermore, neither/ Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro or connected with this inspectio JF Swan 2 .Commissions .NC1524, N-I

                    /Inspector's Signatu*,'    OFNational                                                    Board, State, Province, and Endorsements o/         31--                                     o,5  6

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI I. Owner Duke Energy.Carolinas,LL C .. Date 5/9/2011 526 South Church Street, Charlotte, NC, 28201.. .... ...... Sheet 1 of 2 Address

2. Plant Mc.Guire.Nuclear Station Unit 1 Name 12700 Hagers Ferry Road, Huntersvilie, NC 28078 .591170-01 Address Work Order # (or Repair/Replacement Organization P.O. No., lob No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 5.2.6. South Church Street, Charlotte, NC 28201-1006N Address Expiration Date: N/A
4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME II1 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section Xl used for Repair/Replacement Activity 1998 Edition with the-1999 a-nd _2000 Add-enda-.-

(c) Applicable Section XI Code Case(s) N/A

6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCA-NV-374 Duke Energy 18173 N/A N/A N/A Removed No 1MCA-NV-374 Duke Energy 37821 N/A . N/A N/A Installed No 1 4 . .4 . + . + 4 4 I 4 4 + + 4 4
7. Description of Work Rei Iace~d C~omp)o~n~en~t/Part/Appwiqenanc~e Additional Description Rc placed snubber on hanger IMCA-NV-374 and it's bolting material.
8. Tests Conducted: Hydrostatic F Pneumatic r- Nominal Operation Pressure F Exempt 17 Other FI Pressure PSI Test Temp. _ IF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 :of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 4 in. (nominal) System Class: ASME_Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: :MCFD-1554-02.01 Support/Restraint Sketch/Drawing No(s).: I MCA-NV-374 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NVU-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date May 9 2011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

           -      ~z2  //.-to          -                           , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective 1--/Z/-/

measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing th* certificate neither the Inspector nor his employpý makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Own ' Report. Furthermore, neither the Inspector is employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro connected with this inspection.

JFSwan.* A d7 x. cefit_.,missions NBI 1473-NC 1524, N-i I-spector's Signature /National Board, State, Province, and Endorsements
'Dat/     /         7"-Z/Z- 1Z                         ,20J/

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

1. Owner D-uke Energy Carolinas, .LL C.. ... --- Date 5/9/2011 5_2_6. South _Church Street,. Charlotte, NC, 28.201 .......... Sheet 1 . of 2 Address
2. Plant McGuire Nuclear Station Unit I Name
                             !.2_79QJHa~gerr           aerrsyvRgylle,..NC 28078                                         .591170-12 Address                                                                  Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by DuPke.Energy Caroinas, LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street,. CharlotteNC 28201-1006 . . Expiration Date: N/A Address

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME llI 19 71 Edition, Summer and Winter Addenda, :N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity .1998_Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)
*IMCA-NV-374                 Duke Energy                       18169                       N/A                       N/A                                 N/A        Removed                         No

.IMCA-NV-374 Duke Energy 37829 N/A :N/A :N/A Installed No

7. Description of Work Repiaced Qmp.one.tt/Part/Ap ._urtenance Additional Description Replaced snubber on hanger IMCA-NV-374 and it's bolting material.
8. Tests Conducted: Hydrostatic F Pneumatic F Nominal Operation Pressure r" Exempt F Other F Pressure PSI Test Temp. _

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 4 in. (nominal) System Class: ASMEClass_2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1554-02.01 Support/Restraint Sketch/Drawing No(s).: 1MCA-NV-374 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NVU-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist - Date May9 .2011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION [, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period s to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the In ector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro or connected with this inspection. JF Swan ,Commissions NB] 1473-NC1524, N-i Inspector's Signatur"e National Board, State, Province, and Endorsements oatr,/ 20--//

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner Duke Energy. Carol inas, LI C ... . . . .. Date 5/9/2011 526 South Church Street. Charlotte, NC,.28201 .............. Sheet I of 2 Address
2. Plant McGuire.Nuclear -Station Unit 1 Name 12700 Hagers.Ferry Road, Hluntersville,.NC 28078 591172-01 .

Address Work Order 4 (or Repair/Replacement Organization P.O. No., Job No., etc.)

3. Work Performed by Duke EnergyCarolinas,.LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 .... Address Expiration Date: N/A

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed ition with the 1999 and 2000 Addenda (c) Applicable Section Xl Code Case(s).N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-NV-5555 Duke Energy 22021 N/A N/A N/A Removed No IMCA-NV-5555 -Duke Energy 38085 N/A .N/A N/A Installed No

7. Description of Work Rep laced Com ponent/Part/Appurtenance Additional Description Re placed snubber on hanger IMCA-NV-5555 and it's bolting material.
8. Tests Conducted: Hydrostatic F" Pneumatic F Nominal Operation Pressure r Exempt F Other f7 Pressure PSI Test Temp. _ IF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 4 in. (nominal) System Class: ASME Clas-s-2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1554-02.01 Support/Restraint Sketch/Drawing No(s).: I MCA-NV-5555 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NVT-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. .N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist -'- 4'- Date May 9 ,2011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

     .5"-   'Z                   to        "                         and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his mployer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' eport. Furthermore, neither the Ins tor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from -onnectedwith this inspection. JF Swan - _.-C.m-missions NBI1473-NC1524, N-I Inspector's Signature 1,,,;5 -National Board, State, Province, and Endorsements Date Lis , 20..

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy CarglinasLLC ................ . Date 5/9/2011 526 South Church Street Cha NC, 2 eotte, -. -. . . . . Sheet . ". f 2 Address
2. Plant McGuire Nuclear Station Unit I Name
                          .12C 0LgagesFerryRoad,. Hurntrsvi lie. NC 28078                                              591173-01 Address                                                                     Work Order A(or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke EnergyCarqJinasLLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street. ChaNrotte. NC 28201-1006 N/A Address Expiration Date:
4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME 111 19 71. Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity _1998.Ecdition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, IASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-NV-5556 Duke Energy 21425 N/A :N/A N/A Removed No

IMCA-NV-5556 Duke Energy 38086 N/A/A N/A Installed No
7. Description of Work Re~placed1C-omponlent/P~a~r'IAppt)ur~tenancee Additional Description Re .placed snubber on hanger IMCA-NV-5556.
8. Tests Conducted: Hydrostatic F Pneumatic F" Nominal Operation Pressure F' Exempt F Other F" Pressure PSI Test Temp. _ IF Description (Optional):

FORM N iS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet. 2 of 2 Component Line Size: 4 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1554-02.O1 Support/Restraint Sketch/Drawing No(s).: IMCA-NV-5556 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on N IS-2 Form: MCSRD-NVT-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist J.,-"' Date May 9 ,2011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

Connecticut have inspected the components described in this Owner's Report during the period to -:57 ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report tn accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither the Insp ctor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from oconnected with this inspection.

.F Swan -o " Commissinnt NBI 1473-NC1524, N-I Inspector's Signature - kf National Board, State, Province, and Endorsements Date( f/Z 20/&

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions o'f the ASME Code Section XI

1. Owner . Qke..Energy Carolinas. LLC. . . . . . Date 8/17/2010 526 South Church.hStreet Charlotte,.NC.,2820-l I of 2 Address Sheet
2. Plant McG-uir.e. Nu-cl.e ar_.Stati on Unit I Name 12700 H~ars EFrry_ qad, Hunters NC 28078 .591192-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke ErnegyroIin, . ......

Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street._Charlotte, NC 28201 -1006 Address Expiration Date: N/A

4. Identification of System NS - Containment Spray
5. (a) Applicable Construction Code ASME Il 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section Xl used for Repair/Replacement Activity 1.998.Ed.ition with the 1999 and 2000 Addenda (c) Applicable Section X1 Code Case(s) N/A
6. Identification ofComponents Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

I MCA-NS-91 Duke Energy 18064 N/A N/A N/A Removed No I MCA-NS-91 Duke Energy 37599 N/A N/A N/A . Installed No

7. Description of Work Re placed Component/Part/Appurtenance Additional Description R_eplaced snubber and it's bolting material on hanger I MCA-NS-91
8. Tests Conducted: Hydrostatic F- Pneumatic I- Nominal Operation Pressure FT Exempt F Other FT Pressure_ :PSI Test Temp.

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 10 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1563-01.00 Support/Restraint Sketch/Drawing No(s).: IMCA-NS-91 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NSB-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date August, 17 ,20 10O Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

                 /L-r / I         to F[- /1ý - / o                   ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from oy*nnected with this inspection. JF Swan I r-'----- Commissions NC1524, N-I Date K/ Inspector's Signature [9

                                            '."    /

202 National Board, State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1 I. Owner .. Duke Enrgy £Carolinas,.LL _. .. . . .... .. . . .. . . . . .. Date 9/2/2010 526 South Church Streetj h~arlotte,_C,2820. ..... . ... Sheet 1 of 2 Address

2. Plant McGuire Nuclear Station Unit .1 Name 12700 Hagprýi FeRoa*L Huntersville, NC_28_078 591194-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street_ _haott NC 28201-1006 Address Expiration Date: NS - N/A
4. Identification of System NS - Containment Spray
5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, *N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed ition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed. or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-NS-98 Duke Energy 18120 N/A . N/A N/A Removed No IMCA-NS-98 Duke Energy 38056 N/A . N/A N/A installed No IMCA-NS-98 iDuke Energy 18880 N/A N/A N/A Removed NQ 1MCA-NS-98 . Duke Energy 38053 N/A N/A N/A Installed No

7. Description of Work Re- pced Component/Part/Appurtenance Additional Description Rteplaced snubbers and their bolting material of hanger 1MCA-NS-98
8. Tests Conducted: Hydrostatic F" Pneumatic r" Nominal Operation Pressure F- Exempt F Other Fr Pressure PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 10 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1563-01.00 Support/Restraint Sketch/Drawing No(s).: I MCA-NS-98 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NSB-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist . . Date September 2 20210. Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut  ? have inspected the components described in this Owner's Report during the period 9l I to " , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Own 's Report. Furthermore, neither e Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising frorr r connected with this inspectic . JF Swan *.Commissions :NC 1524, N-I National Board, State, Province, and Endorsements Date6/ 20_ A0

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke EnergyCarolinaL LC_ .... -Date 9/16/2010 526_ South Church Street. CharotteN,2_ ......... Sheet I of 2 Address
2. Plant McGuire Nuclear Station Unit I Name 12_70 ageferr od Hun~tersfyille, NC .28078 *591213-01 Address Work Order 4 (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street. Charlotte, NC 28201-1006 Address Expiration Date: N/A
4. Identification of System VQ-
5. (a) Applicable Construction Code ASME 111 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity .1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, AS ME Code Name of Manufacturer National Other Year Removed. or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-VQ-10 Duke Energy, 15119 N/A ..... N./A. N/A Removed No 1MCA-VQ-10 Duke Energy 3.6870. N/A N/A N/A Installed No

                                                           .1.                            n                        L                                   .1.
7. Description of Work Re -lacedComponent/Part/Appjii1enance Additional Description Rteplaced snubber on hanger IMCA-VQ- 10.
8. Tests Conducted: Hydrostatic F" Pneumatic F Nominal Operation Pressure 17 Exempt F Other F Pressure __ PSI Test Temp. _ F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 6 in. (nominal) System Class: ASMEClass_2 Weld Isometric Drawing NOWs.: N/A Flow Diagram No(s).: .MCFD- 1585-01.00 Support/Restraint Sketch/Drawing No(s).: IMCA-VQ- 10 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-VQA-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A SignedFL G ass, Quality Assurance Technical Specialist -Date September 16 ,20 10 Signed FL Gs Q A Owner or ne T ehnica S iali Owner's Designee. Title - D CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

    ,-                       to    -/                    O, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing t ls certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Own r s Report. Furthermore, neither the spector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro r connected with this inspection. JF Swa_. .. -Commissions NC1524, N-I Inspcto's Sgnau,;National Board, State, Province, and Endorsements e________

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X!

1. Owner Duke IEnergv Carolina-. LILC Date .6/22/201.1 526 S outh Church Street. Charlotte NC, 28201 Sheet 1 of!2 o wuw-rsB
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 591339-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energ Carolinas LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte. NC 28201-1006 ___

Address Expiration Date: N/A

4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME III 19,71 Edition, Summer and Winter Addenda, N/A ýCode Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed ition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

Duke Energy

                           'MCA-ND-304                              14965                                          NA                                   N/A                                       :N/A        Removed                        No 1MCA-ND-304                 Duke Energy                            :38426                                          N/A                                                                              N/A       Installed                      No
                            .  ...                                                       ...   .      ~~. ..~~~~....
                                                                 .. .. ....             .. ... ....      . .. 1. .         . .. .... .. . .....      . .,. .     ....                    ...
7. Description of Work Replaced Component/Part/Appurtenance Additional Description .Replaced snubber on hanger IMCA-ND-304
8. Tests Conducted: Hydrostatic F Pneumatic F' Nominal Operation Pressure F Exempt F Other F' Pressure; ____PSI Test Temp. O_°F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet  ! of Component Line Size: .8 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1561-0 1.00 SupportfRestraint Sketch/Drawing No(s).: 1MCA-ND-304 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: :MCSRD-NDA-005 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date .June 22  :, 20.11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

'North Carolina                                                                  ,j                 , 'Hartford Steam Boiler Inspection and Insurance Company                         ýf
'Connecticut                                                                    have inspected the components described in this Owner's Report during the period "to            2-3         .

n0 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owne 's Report. Furthermore, neither tJy Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro/Tr connected with this inspectio JFF Sw P-, . Commissions NB i 1473-NC1524, N-1 Inspector's Signatu're National Board, State, Province, and Endorsements te- 20.7; 20A

FORM NIS-2 OWNER'S REPORT FOR REPAIR7REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner _DDuke.En.ergy Caro-linas.,_L _ .Date .1/11/2011 526 South Church Street. Charlotte,. NC, 28201 .. Sheet 1 of.2 Address
2. Plant McGOuire. Nuclear--Station- Unit I Name 2700 HagersFeyRoaH.unrsi.lNC_28078 :591340-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Eer gyC___rq.inasLLC .... ...

Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street. Charlotte, NC28201-1006 Address Expiration Date: :N/A

4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME 111 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity _1998. Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-ND-250 Duke Energy 19898 N/A ýN/A N/A Removed No I MCA-ND-250 Duke Energy 38064 N/A " N/A N/A Installed No

7. Description of Work Rpe lacedCormponent/Part/Appurtenance Additional Description Reeplaced snubber and bolting material on hanger IMCA-ND-250.
8. Tests Conducted: Hydrostatic F" Pneumatic F Nominal Operation Pressure r- Exempt 17 Other F Pressure ____PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2  :

Component Line Size: 12 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1563.01.00 Support/Restraint Sketch/Drawing No(s).: IMCA-ND-250 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-FWA-004 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date January, 11 2011 Owner or Owner's Designee, Title/ CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

.North Carolina                                                             and employed by Hartford Steam Boiler Inspection and Insurance Company                              of Connecticut                                                                have inspected the components described in this Owner's Report during the period
/_       -. L-"/*               to      / 7-,and                     state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this ertificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner'tReport. Furthermore, neither the I ector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. JF-Swan CommissionsNC1524,N-1

        /           ,nspector's Signature        fNational                                              Board, State, Province, and Endorsements DateU            /"7                                 '20J---

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas, LI LC Date 9/1/2010 526 South Church Street Cha NC 280 Sheet 1 o2 Address
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagg g___err ~Road, Hq~ersyille.,_NC_2.8.0_78 591378-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Caroinas4,LLC-------.

Name Type Code Symbol Stamp: Authorization No.: 526 South Church Street,.Charlotte, NC 28201-1006 Address Expiration Date:

4. Identification of System BB - Steam Generator Blowdown Recycle
5. (a) Applicable Construction Code :ASME II 19 71 Edition, ýSummer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity -1998 Editi on with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

I MCA-BB-4 10 Duke Energy 20943 N/A . N/A :N/A Rem-oved No 1MCA-BB-410 Duke Energy 38070 N/A :N/A N/A Installed No

7. Description of Work LpaceC~omponent/Part/Apputepaitncep Additional Description replaced snubber on hanger I1MCA-BB34 10
8. Tests Conducted: Hydrostatic r Pneumatic F Nominal Operation Pressure IT Exempt F Other !" Pressure. _ PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of .2 Component Line Size: 3 *in. (nominal) System Class: ASME_Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: .MCFD- 1580-01.00 Support/Restraint Sketch/Drawing No(s).: IMCA-BB-410 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Z 4 Date September 1 ,20 10. Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina "and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period to ,/ ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the nspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from r connected with this inspection.

.JF Swan .                                                                                      Commissions NC1524, N-I Inspec tor's Signature                                                     National Board, State, Province, and Endorsements Dateq            -.. T

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X!

1. Owner Duke Energy Carolinas, LLC hrlt NC 28201 Date 9/1/2010 ..

526 South Church Streetharlot, NCe28201 Sheet 1 of 2 Address

2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagers FerU RoadHuntersvi!e, NC 28078 591379-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street. Charlotte, NC 28201-1006 .K I/A Address Expiration Date: '"
4. Identification of System BB - Steam Generator Blowdown Recycle
5. (a) Applicable Construction Code ASME III 19771 Edition, iSummer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) .N/A 6_ Identification of flnm nonents Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCA-BB-410 'Duke Energy .. 20672 N/A .N/A .N/A Removed No IMCA-BB-410 ;Duke Energy . :38057 N/A .!N/A N/A Installed No.
7. Description of Work Replaced Component /Part/Apurtenance Additional Description replaced snubber on hanger 1MCA-BB-4 10
8. Tests Conducted: Hydrostatic F Pneumatic F Nominal Operation Pressure r" Exempt F Other F- Pressure PSI Test Temp. __

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X! 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 3 in. (nominal) System Class: A SMECClass_2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1580-01.00 Support/Restraint Sketch/Drawing No(s).: IMCA-BB-410 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist , Date September 1 ,2010 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina "and employed by Hartford Steam Boiler Inspection and Insurance Company of

.Connecticut                                                                    have inspected the components described in this Owner's Report during the period
 .     - -*2LL:2,Jto                 .                               and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither the Inpector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. JF Swan*Commissions NC 1524, N- I

                     .Inspector's Signature                                                       National Board, State, Province, and Endorsements Date               -7'20Z_0

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner .. DukeEnergyCarolinas....

C .. . .. Date 8/10/2010 526 South Church Street, Charlotte. NC. 28201 ........ . . Sheet _ of 2 Address

2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hag eys FetM__oa~d, Hu__nt ~svie,NC_2078 :591386-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by DtkeEnergy aroinas, LLC.

Type Code Symbol Stamp: N/A Name Authorization No.: N/A 526 South Church Street Charlotte, NC 28201-1006 Address Expiration Date: N/A

4. Identification of System NI- Safety Injection
5. (a) Applicable Construction Code ASME HI 19 71 Edition, Summer and Winter Addenda, ýN/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-NI-253 Duke Energy 20442 N/A ýN/A N/A Removed No IMCA-NI-253 Duke Energy .18000 N/A ;N/A N/A Removed No IMCA-NI-253 Duke Energy 37593 N/A .N/A . N/A Installed No IMCA-NI-253 Duke Energy 37589 N/A N/A N/A Installed No

7. Description of Work Re. )lce omippnentlPart/A ppurtenanrce Additional Description re placed snubbers and bolting material on hanger I MCA-NI1-253.
8. Tests Conducted: Hydrostatic F- Pneumatic F Nominal Operation Pressure r" Exempt F Other r- Pressure*. PSI Test Temp. _ IF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 4 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N./A Flow Diagram No(s).: .MCFD- 1562-03.00 Support/Restraint Sketch/Drawing No(s).: IMCA-NI-253 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NIB-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date August 10 20 0__ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina in,,P,, 1, Hartford Steam Boiler Inspection and Insurance Company 4ý Connecticut have inspected the components described in this Owner's Report during the period "to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising froml connected with this inspection.

.JF Swan                20
                        ./,y"-Jj7           /r          ,                                            Commissions NC1524, N1
                 -   n-specto r's Signature       I                                                 National Board, State, Province, and Endorsements Date    v

_ _- /Z W w 20L66

FORM NIS-2 OWNER'S REPORT FOR REPA[IRREPLACEMENT ACTIVTY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke En ergyCarolinas LLC Date 8/10/20 10 526 South Church StreetChar.oR, NC,_22 .. .... . . . Sheet 1 of 2 Address
2. Plant McGuire Nuclear Station Unit 1.

Name 12700 Hagers Ferry Road Huntersville,._NC 28078 591387-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)

3. Work Performed by Duke Ener aroinaLL-..... . ..

Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church StreetCharlotte, NC 28201-1006 Address Expiration Date: N/A

4. Identification of System NI- Safety Injection
5. (a) Applicable Construction Code ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 EdIitinn with the lQgO arnd 9A00 Addepndaz ition with the 1999 and 2000 Addenda
                                                                                             ]

(c) Applicable Section XI Code Case(s) N/A

6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-NI-255 Duke Energy 21807 N/A N/A N/A Removed No IMCA-NI-255 Duke Energy .37595 N/A N/A N/A Installed No 71-

7. Description of Work Replaced Component lPart/Appurternhange Additional Description replaced snubber an dbolting material on hanger IMCA-NI1-25 5.
8. Tests Conducted: Hydrostatic F Pneumatic r Nominal Operation Pressure F" Exempt F Other r- Pressure _ PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 4 in. (nominal) System Class: ASME Class_2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1562-03.00 Support/Restraint Sketch/Drawing No(s).: IMCA-NI-255 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NIB-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date JN/A Signed FL Grass, Quality Assurance Technical Specialist \ .',/* Date August 10 2010 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of I Connecticut have inspected the components described in this Owner's Report during the period 4' 2t - Z-0 to .z?3L/ Z/- ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Ow 's Report. Furthermore, neither th nspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro r connected with this inspection JF Sa . Commissions NC1524, N-1 ispctor' s Signature---"-/ I7 National Board, State, Province, and Endorsements Da ,i *, 20

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

1. Owner Duke EnergyCaQroIin-as._L! __ .. ... ... . . .... . . . . .. --
                                                                                             . ..-- ..     ....... .. Date 8/19/2010 526 South Church Street, Charlotte,_NC,_282001  ....                                                 Sheet    I         of 2 Address
2. Plant McGuire Nuclear Station Unit .I Name 12700 Hagersfeay Road, untersvy1ie,,NC28078 591390-01 Address Work Order# (or Repair/Replacement Organization P.O. No., Job No., etc..)
3. Work Performed by Duke Energy Carolinas. LLC Name Type Code Symbol Stamp: N/A Authorization No.: 'N/A 526 South Church Street, CharlotteNC 28201-1006 Address Expiration Date: N/A
4. Identification of System NS - Containment Spray
5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity j!998 E-dition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped ComponentName of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No).

IMCA-NS-88 Duke Energy 14918 N/A N/A N/A Removed No IMCA-NS-88 Duke Energy 37590 N/A N/A N/A Installed No

7. Description of Work Reqplaced Component/Part/Appurtenance Additional Description .re1placed snubber and bolting material on hanger IMCA-NS-88.
8. Tests Conducted: Hydrostatic F- Pneumatic F Nominal Operation Pressure F Exempt iy Other F Pressure __PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: I0 in. (nominal) System Class: ASMECl!ass.2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1563-01.00 Support/Restraint Sketch/Drawing No(s).: IMCA-NS-88 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NSB-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date August, 19 ,20 10 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period ____________to 4'?-- Zand state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither t e Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspectio JF Swan -2. --* Am

                                                   .,,-,,,_.                                   Commissions NC1524, N-I AV    Inspector's Signatul.    /   -        -                                   National Board. State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI I. Owner Duke Energy_CaLrQlinas LLC . . .. ...... .... ..-. Date 6/15/2010 .

             .... 526 South Church Street CharlotteNC,8201 NC                                                             Sheet   I         of f2 Address
2. Plant McGuire Nuclear Station Unit I Name 1?700 HaRqerq Ferry Road Huintersville- NC 28078 591420-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church StreetKCharlotte, NC 28201-1006
                                                 . Address                                                                             Expiration Date:       N/A
4. Identification of System SM - Main Steam
5. (a) Applicable Construction Code ASME III 19 71* Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section Xl used for Repair/Replacement Activity J198 Edition with the 19§99 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-SM-188 'Duke Energy .. . :19959 N/A 'N/A . ..... N/A Removed. No 1MCA-SM-188 :Duke Energy :21404 N/A :N/A N/A Installed No

7. Description of Work Re placed Cosnpone thart/Apngurtenance Additional Description Rieplaced snubber on hanger IMCA-SM- 188.
8. Tests Conducted: Hydrostatic [- Pneumatic F Nominal Operation Pressure I Exempt F Other F Pressure PSI Test Temp. __

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): 2 of 2 Sheet Component Line Size: 3 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1593-01.00 Support/Restraint Sketch/Drawing No(s).: IMCA-SM-188 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-SMW-00i Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Techn ical- Specialist Date June, 15 - 2010 Owner or Owner's Designee, Title -/ CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

.North Carolina                                                                 and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut                                                                    have inspected the components described in this Owner's Report during the period S -                     to                    --            and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither the I pector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. JF Swan PI ,c_,,k:- = Commisinns ;NC1524, N-I Inspector' sSignaturl- National Board, State. Province, and Endorsements Date/11 - /6 2OZV

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the .ASi'IE Code Section XI

1. Owner fluke Fner~v Carolinas LI LC Date 7/15/2010 Duke Energv Ca linas L 526 South Church Street. (Charlotte, NC, 28201 Sheet I of 2 A dA,~
2. Plant McGuire Nuclear Station Unit I Name 12700 Hapers Ferry Road, Huntersville, NC 28078 591421-01 Address Work Order # (or Repair/Replacement Organization P.O. No.. lob No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date:

4. Identification of System SM - Main Steam
5. (a) Applicable Construction Code ASME IlI 192L Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected. ASME Code Name of Manufacturer National Other Year Removed. or Stamped Component Name of Manufacturer Serial No. Board No. Identification Buuilt Installed (Yes or No)

IMCA-SM- 192 Duke Energy 19965 N/A N/A N/A Removed No-IMCA-SM-192 Duke Energy 37855 N/A N/A N/A Installed No

7. Description of Work Rer )laced Comiponent/Part/Appurtenance Additional Description Reeplaced snubber on hanger IMCA-SM-192.
8. Tests Conducted: Hydrostatic I Pneumatic r- Nominal Operation Pressure F' Exempt F7 Other F" Pressure .PSI Test Temp. __

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITr As Required by the Provisions of the AS.ME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 3 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1593-01.03 Support/Restraint Sketch/Drawing No(s).: IMCA-SM-192 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-SMW-001 Applicable Manuftcturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date July 15 .2010 I Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of
Connecticut have inspected the components described in this Owner's Report during the period
        --         -U        to     -- /,                        and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's eport. Furthermore, neither the Inspector r his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or onnected with this inspection.

*JF Swan            0                                                                          Commissions NC1524, N-I Inspetor'       SigntureNational                                   Board. State, Province, and Endorsemnents;

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner Duke F.nerpv Carolinas LI 1C Date 7/15/2010 Duke Enerpv Carolinas L 526 South Church Street. Charlotte, NC. 28201 2 Sheet 1 of A AA....
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 591423-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A
4. Identification of System 'SM - Main Steam
5. (a) Applicable Construction Code :ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected. ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCA-SM-200 Duke Energy *21426 N/A N/A N/A Removed NO 1MCA-SM-200 Duke Energy 37860 N/A :N/A N/A Installed No
7. Description of Work Replaced Component/Part/Appurtenance Additional Description Replaced snubber on hanger IMCA-SM-200.
8. Tests Conducted: Hydrostatic r Pneumatic rT Nominal Operation Pressure I" Exempt F Other Fr Pressure PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 .

Component Line Size: 3 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1593-01.03 Support/Restraint Sketch/Drawing No(s).: I MCA-SM-200 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-SMW-002 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date July 15 ,2010 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

.North Carolina                                                             and employed by Hartford Steam Boiler Inspection and Insurance Company                            of Connecticut                                                                have inspected the components described in this Owner's Report during the period (7       --
  • z L to 17- ZS --Z D. and state that to the best of my knowledge and belief, the Owner has performed examinations andtaken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner'Aeport. Furthermore, neither the Inspect nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o nnected with this inspection. Commissions NC1524, N-I In sSignature National Board. State. Province, and Endorsements Date9 , 20OJ

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke EnergyCarolinas, LLC Date 8/19/2010 526 South Church Street CharlotteNC_28 Sheet I of 2 Address
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagers Ferry Road* Huntersville, NC 28078 591484-01 Address 591484-01 Work Order # (or RepairfReplacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC ..

Name Type Code Symbol Stamp: N/A Authori7atinn No: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME 111 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity J..998 Edition with ththe ,1999 and_20.00_Adden.d.a (c) Applicable Section Xi Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMC-1683-NVOI-R8A, Duke Energy .18117 N/A N/A N/A Removed No 1MC-1683-NVOI-R8A Duke Energy 21453 N/A N/A :N/A Installed No

7. Description of Work Re_ laced Component/Part/Appiurte.nanc£e Additional Description Re placed snubber on hanger IMC- 1683-NV-0 1-R8A
8. Tests Conducted: Hydrostatic F Pneumatic r- Nominal Operation Pressure 17 Exempt F Other -" Pressure ___ PSI Test Temp. _ °F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 2 in. (nominal) System Class: ASM Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1554-03.01 Support/Restraint Sketch/Drawing No(s).: MG-I1683-NV-0 -R8A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-MC-1683-01 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date August, 19 ,20 10.. Owner or Owner's Designee, Title / CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

;North Carolina                                                            and employed by Hartford Steam Boiler Inspection and Insurance Company                            of Connecticut                                                                 have inspected the components described in this Owner's Report during the period 131-/                           to        -              10 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. JF Swan Commissions NC1524, N-I

                     /nspector's Signature                                                    National Board, State, Province, and Endorsements Date                           t9                     . 20/o

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

1. Owner Duke Enerav Carolinas. LILC Date .5/19/2010 2
                  'i2t~ Snnth flhitrch Sftee~t~

526 South ChurchA *[*,I.... StreetI Charlotte _NC, 28201 Sheet 1 of

                                 ,GUure55
2. Plant McGuire Nuclear Station Unit .1 Name 12700 Hagers Road Huntersville, NC 28078 591489-01 Address WoTk Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: :N/A Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A
4. Identification of System CF - Feedwater
5. (a) Applicable Construction Code ASME III 1971: Edition :Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section X1 used for Repair/Replacement Activity 1998 Ed,ition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-CF-152 Duke Energy 20525 N/A ýN/A N/A Removed No IMCA-CF-152 :Duke Energy 15870 N/A N/A N/A Removed No

lMCA-CF-152 :Duke Energy .36869 .N/A N/A N/A Instled No IMCA-CF-152 Duke Energy 36868 N/A N/A N/A Installed No
7. Description of Work )l]ace(d -Comp&uenV4WAp-pujqr-Lanlc-e Additional Description R(~placed snubbers on hanger IlMCA-CF- 152
8. Tests Conducted: Hydrostatic F Pneumatic r-T Nominal Operation Pressure IF Exempt F Other F Pressure _ PSI Test Temp. __ F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of Component Line Size: 18 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: 'N/A Flow Diagram No(s).: MCFD- 159 1-0 1.01 Support/Restraint Sketch/Drawing No(s).: IMCA-CF-152 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-CFC Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist ..... Date May 19, 20 0 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

*Connecticut                                                                     have inspected the components described in this Owner's Report during the period I.--- --                     .to .      - ,          - /'t     , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner Report. Furthermore, neither thePspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. JF Swan - InseCommissions 'NC 1524, N- I Inspct.or s Signature -National Board, State, Province, and Endorsements DatCl -5 0::U ,20:/"0

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas, LILC Date 7,/19/2011 526 South Church Street, Charlotte, NC. 28201 Sheet I" of 2
2. Plant McGuire Nuclear Station Unit I Name 12700 Hapers Ferry Road, Huntersville, NC 28078 ,591530-01 Address Work Order # (or RepairlReplacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: 'N/A
4. Identification of System NS - Containment Spray
5. (a) Applicable Construction Code ASME III 192L Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed[ition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A 6_ rdentification of Com nenntn Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-NS-85 .. Duke Energy 21666 N/A :N/A :N/A Removed No 1MCA-NS-85 zDuke Energy 37822 N/A N/A N/A Installed No IMCA-NS-85 Duke Energy 21715 N/A N/A N/A Removed No 1MCA-NS-85 Duke Energy 37828 N/A :N/A N/A Installed No

7. Description of Work Ret ilaced Component/Part/Appurtenance Additional Description Reeplaced snubbers and their bolting material on hanger I MCA NS-85.
8. Tests Conducted: Hydrostatic F" Pneumatic F" Nominal Operation Pressure FT Exempt [ Other [- Pressure ___PSI Test Temp. _ IF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of ý2 Component Line Size: 10 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1563-01.00 Support/Restraint Sketch/Drawing No(s).: I MCA-NS-85 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NSB-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist. 2 Date July 19 ,2011. Title Owner or Owner's Designee, CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

.North Carolina                                                                 and employed by Hartford Steam Boiler Inspection and Insurance Company                             of Connecticut                                                                    have inspected the components described in this Owner's Report during the period
                    -                  ZL~LZ.............to... . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither the I ector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. J Swan  ! Commissions .NB 1473-NC 1524, N-I Inspector's Signature I- National Board, State, Province, and Endorsements (/ Date Date 7/c[ 201/ 20-&

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

1. Owner Duke EnejgyCarolinas, LLC Date 7/22/2010 526 South Church Street CharlottN, NC 28201. --- ------- Sheet 1 of 2 Address
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Ha ers Feury Road Huntersville NC 28078 59.1544-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street. Charlotte. NC 28201-1006 Address Expiration Date: N/A

4. Identification of System SM - Main Steam
5. (a) Applicable Construction Code ASME I1 19 71 Edition, Summer and Winter Addenda, :N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity .198 Edition with the 1999 and2000 Ad denda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-SM-69 Duke Energy 16548 N/A N/A N/A Removed No IMCA-SM-69 Duke Energy .17371 N/A N/A N/A Removed No 1MCA-SM-69 Duke Energy .36600 N/A N/A N/A Installed No IMCA-SM-69 "Duke Energy 36599 N/A N/A N/A Installed NO

7. Description of Work Re placed Com onent/Part/Appurtenance Additional Description R( placed snubbers on hanger I1MCA-SM-69.
8. Tests Conducted: Hydrostatic F" Pneumatic r- Nominal Operation Pressure r" Exempt F Other F" Pressure PSI Test Temp. _ IF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 36 in. (nominal) System Class: ASMECClass 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: .MCFD- 1593-01.03 Support/Restraint Sketch/Drawing No(s).: IMCA-SM-69 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-SMA-004 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist N-4:4% Date July 22 ,20 10 4 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period 17- 24& - le to __- 26? - /O , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the In ector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. JF Swan 6]..z- .e.. -- Commissions NC1524, N-I 7'

              /       Inspector's Signature                                                       National Board, State, Province, and Endorsements I

FORM NIS-2 OWNER'S REP( )RT FOR REPAIR/REPLACEMENT ACTIVITY As Required by tihe Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas.aLLC Date 6/24/2010
                  .526_-South Church Strehet. Charlotte,N , 282
                                                                                              ..         ......           Sheet I           of 2 Address
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 :591553-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas,_LLC Name Type Code Symbol Stamp: N/A Authorization No.: ýN/A 526 South Church Street. Charlo__e_ NC 28201-1006 Address Expiration Date: N/A
4. Identification of System SM - Main Steam
5. (a) Applicable Construction Code ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 EdLition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Comp onents Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-SM-19 Duke Energy 16558 N/A N/A Removed N.o. IMCA-SM-19 ;Duke Energy 36890 N/A :N/A N/A Installed No

7. Description of Work Repplaced smponerntph.aertIA ppuienance Additional Description re placed snubber on hanger IMCA-SM-19
8. Tests Conducted: Hydrostatic IT Pneumatic F" Nominal Operation Pressure - Exempt r" Other I- Pressure _ PSI Test Temp.

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 42 in. (nominal) System Class: ASMEClass 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1593-0i.00 Support/Restraint Sketch/Drawing No(s).: IMCA-SM- 19 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-SMA-002 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist N$t' ,.. Date June 24 ,2010 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by-Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

  • jsi*zL.to. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspecto nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owne s Report. Furthermore, neithe e Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from r connected with this inspecti

                       .JF               wanCommissions                                                              NC 1524, N-I Inspector's Signature S                       /National                                                     Board, State, Province, and Endorsements Date                                                 , 2q

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas, LLC Date ý6/24/2010 526 South Church Street-,Charloe _C 20.. .. Sheet 1 of 2 Address
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagers Ferry Road Huntersville, NC 28078 ,591553-12 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street, Charlotte NC 28201-1006 Address Expiration Date:

4. Identification of System SM - Main Steam
5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, ;N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed ition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Comronents Corrected. ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCA-SM-19 Duke Energy 15682 N/A N/A N/A Removed No IMCA-SM- 19 Duke Energy 36882 N/A 'N/A N/A Installed No
7. Description of Work Re placed Comp onent/Part/Appau-ten ance Additional Description re placed snubber on hanger 1MCA-SM-19
8. Tests Conducted: Hydrostatic F Pneumatic r Nominal Operation Pressure F Exempt r- Other r Pressure ;PSI Test Temp. __

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 42 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1593-01.00 Support/Restraint Sketch/Drawing No(s).: 1MCA-SM-19 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-SMA-002 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist C .s Date June 24 2010 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

 ._Connecticut__                                                                have inspected the components described in this Owner's Report during the period
                    -,   C)

[O to ---. "( () ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing th* certificate neither the Inspecto or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this OwneV'* Report. Furthermore, neith e Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from/* connected with this inspect' n.

JF Swan , A. c . /*"--- . ....... Commissions NC1524, N-I Inspector's SignatLr* National Board, State, Province, and Endorsements I

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner Duke Einergv Carolinas. LILC Date 10/25/2011 526 So uth Church Street, Charlotte, NC, 28201 Sheet I of 2
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 592066-31 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Enerpv Carolinas. LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street. Charlotte, NC 2820 1-1006 NI/A Address Expiration Date: '*"'

4. Identification of System BB - Steam Generator Blowdown Recycle
5. (a) Applicable Construction Code ASME III 192-1 Edition,: Summer and Winter Addenda, ;N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Nameof Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCA-BB-402 'Duke Energy N/A NA 'N/A N/A Installed.No
7. Description of Work Rer )laced Component/Part/Appurtenance Additional Description Reeplaced bolting material on clamp of hanger I MCA-BB-402.
8. Tests Conducted: Hydrostatic F Pneumatic F" Nominal Operation Pressure F Exempt F Other F Pressure PSI Test Temp.

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet of Component Line Size: 2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: N/A Support/Restraint Sketch/Drawing No(s).: IMCA-BB-402 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on N IS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist

  • Date October 25 _ 20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of
 .NorthCarolina                                                            and employed by Hartford Steam Boiler Inspection and Insurance Company                            of Connecticut                                                               have inspected the components described in this Owner's Report during the period A                          to....*_......-..    '           , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro or connected with this inspecti

.JF Swan                                                                                       Commissions .NBI 1473-NC 1524, N-I National Board, State, Province, and Endorsements D      _            _             _             20

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas. LL -'C Date 10/15/2011 526 South Church Street. Charlotte. NC. 28201 Sheet '1I of 2 Address
2. Plant McGuire Nuclear Station Unit 1 Name

_12700 Hapers Ferry Road. Huntersville. NC 28078  ! 592066-35 Address 592066-35 Unit Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)

3. Work Performed by Duke Energy Carolinas. LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street. Charlotte. NC 28201-1006 Address Expiration Date: N/A
4. Identification of System BB - Steam Generator Blowdown Recycle
5. (a) Applicable Construction Code ASME Ill 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Com onents Corrected, ASME Code Name of Component Manufacturer National Other Year Removed, or Stamped Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1BB4 Borg Warner 9090 114 V File# 851 1976 Removed Yes
                                                          .23BRW                       2747                    N/A                                   2011      Corrected                        Yes I.!BB4                   Flowserve 11~~~2                                                        ... ..                  .
                                                                                                                             . .. .. . .r*...            1
7. Description of Work Replaced Component/ParttAppurtenance Additional Description Cut out and replaced valve I BB4.
8. Tests Conducted: Hydrostatic " Pneumatic - Nominal Operation Pressure P7 Exempt r Other " Pressure 1062 PSI Test Temp. 553 OF Description (Optional): test performed per procedure MP/0/A/7650/076.

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: MCFI- BB27 & 29 Flow Diagram No(s).: MCFD-1580-01.00 Support/Restraint Sketch/Drawing No(s).: N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE 1certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist ", . Date October 15 ,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by. Hartford Steam Boiler Inspection and Insurance Company of

.Connecticut                                                                 have inspected the components described in this Owner's Report during the period
                              /"to        -     /Z-       //,     and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

.JF Swan                            /'.mm.q~mnn*

6/Inspector's/9 o2 v-L.,. NBI 1473-NC 1524. N-1 National Board, State. Province, and Endorsements

       -igna(ure-_--/

Dateo - 201//

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES* As Required by the Provisions of the ASME Code, Section III, Division 1 2

                                                                             -3Pg.                                                                                   1 of
1. Manufactured and cartified by Rowserve Corporation, 1900 Sou id 5;unders St. Raleiqh. NC 27603.:...-

mnamna mid addre1 aoN Ceriflcate Holderl

2. Manufactured for Duke Energy P0 BoX 37925 Charlotte, Nc .28237 Inama pin d eadresa of Purhaasr)
3. Location of installation McGuire Site 13225 Hagers Ferry (HWY 73) Huntersvlile, NC 28078-8985; (name end nddrea.l GSate Valve Drawing 74S0 Rov. E CRN N/A
4. Model No., Series No., or Type 1500
5. ASME Coda, Seotion III,Division 1: 1971,--' Summer 1973
  • 2 " N/A _

(adldenj (addanda datal (l j (Code Cue no.- Pump or valve Valve Nominal inlet size 2 Outlet size 2 0. (in) (in.)

7. Material:

(a) valve Body SA182-F316 Bonnet SA18Z-F316 Disk SA351-"FMM Bolting N/A (b) pump Casing C6ver - olcing - (a) ib) (a] (d) (e) Cort Neil V'zdylCasing Bonnet/Cover Diskc Holder's Board Serial Serial seralh serial No. No. No. No. No. 228RW.. 2746V ____ A2-150 .- ,~ N9S19-10 LO265-1-2 '

          -23BPW~                             2747'-                                                                                                          N9519-11 AZ-151                                 L0265-1-2 24BRW       j/                      2748.                                                                                                            W919-12 in the or drawings may be used provided (ii sIze I. SWx 11,12) Nforrnstior.

li~, eketchea, foam ofinlornnetion

                                 'Supplamen~l                                                                                           in item. 1 through 4 on
*Supplemental Information In the form of rim", asktrhes, or drawings may Ibe usned provided (1) size Is 81/zx 11, 12) ihformatiorn In Items I through 4 on iz included on each sheet, (31eacth sheet is numbered and the number of t.heats Is reorded at the top of th*s form.
                                                                     ,7f            0-72             -o                            7Y

FORM NPV-1 (Biack - Pg. 2 of 2 "9 Certificate Holder'i Serial No. 2ZBRW THU 248RW conditions 1200 psi 567F or valve pressure class 1500

a. Design8.Dsgncniios 10 (pra.*ural 567-"* 1 o (tamfperal a- Cold working pressure 3600 " . . psi at I OUT 540 VI000
10. Hydrostatic test psi. Disk differential te,:t r:'Qe&ure psi
11. Remarks: S 60701 DQAN PIPE- MATL: SA312-304. HEAT: E3JL Z CERTIFIrCA1ON OF DESIGN P E. State SC Rag. no. 4237 Design Specification certified by R..MIller Design Report certified by N/A P.E. state . Reg. no. N/A CERTINiCAIE OF COMPLIANCE We ertify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Coda, Section III, Division 1.N-1562 1-2-1 N Certificate of Authorization No. N-_ _ _2_ Expires 11-26-12 Date -iLLZZ2ALt Name HO~ev Co~oration IN Cartlflenta loldvl1
                                                                                   *.ne~i                             :         louthailzed rrpre*antnu5,'

cMRTiW(CArE OF INSPEeTION I, the undersigned, holding a valid commission Issued by the Naijonal Board of Boiler and Pressure Vessel Inspectors and the State or Province and employed by l HB C of NC 10 f Haof Haf .. .. . ,..... have inspected the pump, or valve, d6scribed In this Data Report on

         /.2/       IL-..      "~ .and stat thatto the best of my kiowledge and belief, the Certificate Holder has constructed this pump, or valve, In aorcrdanra with the ASME Code, Section IIl,Division 1.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceqrning the component described In this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any persbhal injury or property damage or a loss of any kind ariling from or connected with this inapticion. Date 2Y&nLL Signed Commissions ,-J,6'/7o(f 0 Al AC-.*"3-

                                                                                ),I7         7Notr.                       (md. andoruawne sod temRmev. and no.1

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Enerpv Carolinas. LILC Date 10/16/2011 526 South Church Street. Charlotte, I NC, 28201 Sheet .1 of 2 Arldrp*
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 592067-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Enemy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 - . . . . "NA/A "

Address Expiration Date: £ "fl

4. Identification of System BB - Steam Generator Blowdown Recycle
5. (a) Applicable Construction Code ASME I11 1971 Edition, Summer and Winter Addenda, ýN/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section Xl Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1BB5 Borg warner 9079 86 V File# 822 :1976 Removed Yes IBB5 Flowserve 05BPK 2502 N/A .2009 Installed Yes
7. Description of Work Replaced Comoonent/Part/Agpourtenance Additional Description .Cut out and replaced valve IBB5
8. Tests Conducted: Hydrostatic F- Pneumatic r Nominal Operation Pressure P' Exempt F" Other F- Pressure .953 PSI Test Temp. 530 OF Description (Optional): test performed per procedure MP/O/A/7650/076 on w/o 1960873 (IS1 test 6-b).

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of' 2 Component Line Size: 2 vin. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: MCFI-IBB7 & II Flow Diagram No(s).: :MCF D -1580-0............... .... .....

Support/Restraint Sketch/Drawing No(s).: N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: *PIP# M-04-2672 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date NIA Signed IFL Grass, Quality Assurance Technical Specialist Date October 16 "120 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

ýNorth Carolina                                                                    and employed by Hartford Steam Boiler Inspection and Insurance Company                                        of Connecticut                                                                       have inspected the components described in this Owner's Report during the period 9-      2*: /7                  to "e"         /9"                 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection F Swan L, .Commissions NBI 1473-NC1524, N-I Inspector's Si gna ture .National Board. State. Province, and Endorsements Date /......... . 20.

pc 6I011 0'9L I FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES* As Required by the Provisions of the ASME Code, Section III, Division 1 P!g. 1lof* 2

1. Manufactured and certified by. Rowserve Corporation, 1900 South Saunders St. Raleigh, NC 27603 (name and address of N Certificate Holder)
2. Manufactured for Duke Energy PO Box 37925. Charlotte, NC 28237 Iname andaddress of Purchase)
3. Location of installation -McGuire Site 13225 Hagers Ferry (HWY 73) Huntersville, NC 28078-8985 Iname and address)
4. Model No.. Series No., or Type 1500# Gate Valve Drawing 74450 Rev. C CRN N/A
5. ASME Code, Section III, Division 1: 1971 Summer 1973 2 N/A ladition) (addenda date (Ictas) (Code Case no.)
6. Pump or valve Valve Nominal inlet size 2 Outlet size 2 tin.) fin.)
7. Material:

(a) valve Body SA182-F316 Bonnet SA182F316 Disk SA351-F.8M Bolting N/A (b) pump Casing Cover Bolting ta) Wb' Wc (d) (et Cen. Nat'l BodylCasing Bonnet/Cover Disk Holder's Board Serial Serial Serial Serial No. No. No. No. No. 38427-1-3--__ N9S19-8 0413PK 2501 .ef -n- OSBPK 2502por A2-79 18427-1-4 N9519-9

  *Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size Is 81/2 x 11, (2) information in Items 1 through 4 on this Data Report is included on each sheet. (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.

igf 0(a/7 e I

FORM NPV-1 (Back - Pg. 2 of 2 02BPK THRU O5BPK /7 Certificate Holder's Serial No. 02BPK___________

8. Design conditions 1200 psi 567 *F or valve pressure class 1500 (pressure) Itempetature) 0
9. Cold working pressure 3600 psi at 100 F 5400 3960
10. Hydrostatic test psi. Disk differential test pressure psi
11. Remarks: S.Q. 53881 DRAIN PIPE- MATL: SA312-304. HEAT: 801951 CERTIFICATION OF DESIGN R.E.Mi _____________er_____SC 4237 R.E.MilPer PE. State S Reg. no. 42-37 Design Specification certified by Design Report certified by N/A P.E. State NIA Reg. no.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to th~e rules for construction of the ASME Code, Section III, Division 1. N Certificate of Authorization No. N-1562 Expires 11-26-09 Date /O Name Flowserve Corporation Signed IN cer~tifcate Holder) Signed reenade CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NC and employed by HSB CT

                         . of    Hartford, CT                                    have inspected the pump, or valve, described in this Data Report on 11, 13         &1          , and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code, Section III, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Date Sign Commissions N-.,(- O lAutIIts ucles Inspector INefl'.Bd. tinsl. endorsements) and State Oatfoy. end no.) uto 4+9 3toG/7 7

FORM NIS-2 OWNER'S REPORT FOR REPAIR/RE PLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke FnerLv Carolinas. LILC Date 10/16/2011 526 South Church Street, Charlottea, NC 28201 Sheet I of 2 Address
2. Plant McGuire Nuclear Station Unit I Name 592068-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No.. etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date:

4. Identification of System BB - Steam Generator Blowdown Recycle
5. (a) Applicable Construction Code ASME lII 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed ition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Namneof Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)
                          .BB6 Borg Warner                      9076                        83                       V File# 822                          1976      Removed                          Yes IBB6                      Flowserve                        22BRW                       2746                    N/A                                   2011      Installed                        Yes
7. Description of Work Replaced Component/Part/Appurtenance Additional Description Cut out and replaced valve IBB6
8. Tests Conducted: Hydrostatic F Pneumatic F Nominal Operation Pressure F, Exempt F Other F Pressure 953 PSI Test Temp. 530 OF Description (Optional): test performed per procedure MP/0/A/7650/076 on w/o 1960873 (ISI test 6-b.

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: MCFI-1BB6 & 42 Flow Diagram No(s).: MCFD-1580-01.00 Support/Restraint Sketch/Drawing No(s).: N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: PIP# M-04-2672 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist " Date October 16 ,2011 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

*Connecticut                                                                have inspected the components described in this Owner's Report during the period
        "          -         to /iZi"                     i    , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro or connected with this inspection

*JF Swan,.      V LOY,                                                                          Commissions NBI 1473-NC1524, N-I National Board. State, Province, and Endorsements Da *_       _-           _/_                     .?,20_

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS Oft VALVES* As Required by the Provisions of the ASME Code, Section III, Division 1of 2

1. Manufactured and certified by Rowserve Corporation, 1900 South Saunders St. Raleigh, NC 27603 n ddr&W of N Car'tte0ta N

(.. .. .and 6d..l

2. Manufactured for Duke Energy PO Box 37925 Charlotte, NC 28237 (nOme and Sddrtas of Putchaser)
3. Lovanon of installation McGuire Site 13225 Hagers Ferry (I (AY 73) Huntersville, NC 28078-8985 Drawing 74450 Rev. CRN N/A
4. Model No., Series No., or Type 1500# Gate Valve
5. ASME Code, Section I1l, Division : 1971 Summer 1973. 2 -. N/A C=ltlznl l0"(addendsdetal (dau (Cedo Cain no.1 Nominal inlet size .2 Outlet size 2
6. Pump or valve Valve i,n. oInr.)
7. Material; (a) valve Body SA182-F316 Bonnet SA182-P316 Dirk SA3S1-U8M Botitg NA (b) pump Casing Cover - oltiig Ia) (bi (cl ld) (el Cert. Natl Body/Casing Pom'et/Cover 1 fHolder's Board Serial serial Serial No. No. No. No. No.
         ' 22BRW .,                            2746        ./                      A2-150      7,    -`

L0265-1-2I WS539-10 23BRW .X" 2747-" A2-151 , N9519-12. L0265-1-3 '

  • R4BRW 2748. A245ZE N9519-12 (2) Inforrriadon in items 1 through 4 on this Data FAp Supplemental Informaation in the fonm of l"Sts. sketches, or drawings ma~,-

Is Included on each shoot, (3)each sheet isnumbered and the nurnijqr of sheets Is recordecs at uim no..

W FORM NPV-1 (Back - Pg. 2 .of 2 22.BiWTHRU 243RW Certificate Holder's perial No. B. Design conditions 1200 psi 567 .. *F or valve pressure class 1.00 (prasaurlI atnparatut bi

9. Cold working presur
   -10. Hydrostatic te5t
                                    ,      3600,
                                                  .00 psi.

J4000 psi at 100F4 Disk differential test prressure 7 psi

11. Remarks: S-O, 60701 ......

DIWAIN IPE-- MAUL: SA312-304. HEAT: E33L . _," CERTIr-CATION OF DESIGN Design Specifigatlon certified by R.E.Milier P.C. State SC Reg. rio. 4237 Design Report certified by - N/A RPE. State N/A Reg. no. CERTIFICA7 E OF COMPLIANCE We oeify that the statements made in this report are corr-e.t ,ad that this pump or valve conforms to the- rules for construction of the ASME Code, Section III, Division 1. 11-26-12 N Certifloate of Authorization No. N-1562 -' Expires Date Name Flowserve corpoatio Signed___ (N C llertif Ica Hold, I I (suchorixd repfaantdvole-CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of NC and employed by HSB CT I of Hadford, CT have inspected the pump, or valve, described In this Data Report on

       "     o         r                     and state that to the best of my knowledge and belief, the Certificate Hoider has constructed this pump, or valve, in accordan6 with the ASME Code, Section III, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or Implied, ooncernlng the component described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection J.. Date Sind-- Commissions A4614(-70' AlJ/ -AJ"IV'Z I pdr.ri I utnq1=d Iuc~br Nonf.6d. lnal. anaoromerntsn d atsuaprov. prid nb.-I stav

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas, LiLC Date 10/15/2011 526 South Church Street.-Charlotte, NC, 28201 Sheet 1 of 2
                              ,. A
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1784845-04 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte. NC 28201-1006 Address Expiration Date: N/A
4. Identification of System
5. (a) Applicable Construction Code ASME III 1971 Edition, Summerand Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

INC57 TRW Mission 5 1-5293 N/A 1978 Installed Yes 7, Description of Work Replaced Component/Part/Appurtenance Additional Description Replaced disc in valve INC57 8, Tests Conducted: Hydrostatic F Pneumatic F" Nominal Operation Pressure I7 Exempt FT Other F" Pressure PSI Test Temp. IF Description (Optional): test performed per procedure MP/O/A/7700/045.

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions ofthe ASME Code Section XI 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 4 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: MCFI-INCi8 Flow Diagram No(s).: MCFD-1553-02.0I Support/Restraint Sketch/Drawing No(s).: N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date October 15 ,20-Ll-Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

.North Carolina                                                               and employed by Hartford Steam Boiler Inspection and Insurance Company                            of
Connecticut have inspected the components described in this Owner's Report during the period
          -                    to/ 10         4 / 7 -- //          and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his em loyer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspe r nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro* 7 or connected with this inspection. JF Swanf 4y_,.t. ... ]- /7 ... Commisions NBI1473-NC1524, N-I Inspector's Signature / National Board, State, Province, and Endorsements DaC____ 201/

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energv Carolinas. LILC Date '9/27/2011 526 South Church Street. Charlotte, NC. 28201 Sheet :I of.2
2. Plant McGuire Nuclear Station Unit _1 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1794709-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: .N/A 526 South Church Street. Charlotte. NC 28201-1006 526 South Church Street- Charlotte NC 28201-1006 Expiration Date: IN/A Address
4. Identification of System VQ - Containment Air Release and Ventilation
5. (a) Applicable Construction Code ASME III 1971 Edition, -Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section Xl used for Repair/Replacement Activity 1998 Ed ition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCR-VQ-514 Duke Energy 21712 N/A N/A N/A Removed No IMCR-VQ-5 14 IDuke Energy 37870 N/A N/A N/A. Installed No
                            . . . . .. . . . . . . ..   .    ..   ..,  , .  . .. .  ..       .   !i..... ... . ......ill... ....... .............. .. ..
7. Description of Work Replaced Component/Part/Appurtenance Additional Description .Replaced snubber on hanger IMCR-VQ-514
8. Tests Conducted: Hydrostatic I Pneumatic F Nominal Operation Pressure I" Exempt F OtherF Pressure ___ PSI Test Temp.

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 6 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1585-01.00 Support/Restraint Sketch/Drawing No(s).: IMCR-VQ-514 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist '? 4 Date September 27 ,20 1L Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period
   ' 2        -'7. /./ "to          .,tI*.--"-I+/-L                 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the l pector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. IJF Swan . Commissions NBI 1473-NC1524, N-I Inspector's Signature' 11 National Board, State, Province, and Endorsements Cte2 - 2o_1/

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Enerav Carolinas, LI LC Date 9/27/2011 926 South Church Street.

Charlotte, NC, 28201 Sheet 1 of 12 526 South Church Street

2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1794711-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas. LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 XT/ A Address Expiration Date:

4. Identification of System VQ - Containment Air Release and Ventilation
5. (a) Applicable Construction Code ASME III 1972L Edition, Summer and Winter Addenda, !N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed. or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCR-VQ-506 Duke Energy 19219 N/A .. N/A N/A Removed No IMCR-VQ-506 Duke Energy 37824 N/A N/A N/A Installed No

7. Description of Work Rev placed Component/Part/Appurtenance Additional Description Retplaced snubber and it's bolting material on hangerI MCR-VQ-506. _________________
8. Tests Conducted: Hydrostatic ' Pneumatic r Nominal Operation Pressure rT Exempt [ Other rT Pressure. PSI Test Temp. _ IF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 6 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A.

Flow Diagram No(s).: MCFD-1585-01.00 Support/Restraint Sketch/Drawing No(s).: I MCR-VQ-506 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist - Date September 27 ,20 1L Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

.North Carolina                                                                and employed by Hartford Steam Boiler Inspection and Insurance Company                            of
.Connecticut                                                                   have inspected the components described in this Owner's Report during the period 7-     a           /           to            R.
                                                .        L7--{    , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from orhnected with this inspection. JF Swan (I / ,-- *2----- -r'-p Cnmmisinno NBi 1473-NC1524, N-I Inspector's Signature National Board, State, Province, and Endorsements Date r 9 20L/

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner .......... ~ Caroli.. .. a.. I-- LC Date 9/30/2011 Duke Energv Carolinas L 526 South Church Street.I Charlotte, NC, 28201 Sheet :;1 of .2 Address
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Haaers Ferry Road. Huntersville, NC 28078 .1794735-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Eneray Carolinas, LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street. Charlotte, NC 28201-1006 Address Expiration Date: N/A

4. Identification of System NI - Safety Injection
5. (a) Applicable Construction Code ASMEIII 1921 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

NI-100-04-Y Duke Energy 2325 N/A N/A N/A Removed No NI-100-04-Y Duke Energy 37043 N/A N/A N/A Installed No

7. Description of Work Revilaced Component/Part/Appurtenance Additional Description Re*placed snubber and it's bolting material on hanger I MCR-S-NI- I 00-04-Y
8. Tests Conducted: Hydrostatic FT Pneumatic [' Nominal Operation Pressure F Exempt F Other F Pressure PSI Test Temp.

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-l 562-02.00 Support/Restraint Sketch/Drawing No(s).: IMCR-S-NI- 00-04-Y Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist \ " " . Date September 30 , 2011L Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

 !NorthCarolina                                                                and employed by Hartford Steam Boiler Inspection and Insurance Company                            of
'Connecticut                                                                    have inspected the components described in this Owner's Report during the period
                 -to                                                 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro r connected with this inspec n. iJF Swan Commissions NBI 1473-NC1524, N-I Inspector's SignatU e " National Board, State, Province, and Endorsements

                                                              /_/

L

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Eneray Carolinas, L LC Date 10/3/2011 526 South Church Street, Charlotte, NC, 28201 Sheet I of 2 A AAre
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1794752-01 Address Work Order # (or Repair/Replacement Organization P.O. No.,.lob No., etc.)
3. Work Performed by Duke Fnergv Carolinas. LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street. Charlotte. NC 28201-1006 "KI/A Address Expiration Date: IN'V*
4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME IIl 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCR-NV-1214 Duke Energy 19955 N/A N/A N/A Removed No IMCR-NV-1214 Duke Energy 37610 N/A N/A N/A Installed No
                                      ]         i             "         "
7. Description of Work Re )laced Component/Part/Appurtenance Additional Description R_eplaced snubber on hanger IMCR-NV- 1214
8. Tests Conducted: Hydrostatic - Pneumatic F Nominal Operation Pressure F' Exempt F' Other F- Pressure PSI Test Temp. *__

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 3 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1554-01.02 Support/Restraint Sketch/Drawing No(s).: IMCR-NV- 1214 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date October 3 ,20 1I Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

.Connecticut                                                               have inspected the components described in this Owner's Report during the period
7o 1/- -'- -and/ state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neithethe Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fromi connected with this inspec . Commissions NBI 1473-NC1524, N-I Inspector's Signat~un- °National Board, State, Province, and Endorsements 1o- /

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner fluke Fnert~v ('.arnIin~ 1.1 L LC Date :10/3/2011 Duke Enerpv C olinas 526 South Church Street. Charlotte, NC, 28201 Sheet 1 of 2 526outhChuch Sree
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hacers Ferry Road. Huntersville. NC 28078 1794755-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: ....

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME II 197L Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code CName of om ponentIn Manufacturer National Other Year Removed, t l e(or Stamped Y so N )

Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) IMCR-NV-1213 Duke Energy 21679 N/A :NA N/A Removed No IMCR-NV-1213 Duke Energy 37603 N/A N/A N/A Installed No

7. Description of Work .Replaced Comnonent/PartlAppIurtenance Additional Description Replaced snubber on hanger IMCR-NV- 1213
8. Tests Conducted: Hydrostatic F' Pneumatic F" Nominal Operation Pressure F Exempt 1l Other F Pressure PSI Test Temp. _

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions oftthe ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): 2 2 Sheet of Component Line Size: 3 in. (nominal) System-Class: ASMEClass2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1554-0l .02 Support/Restraint Sketch/Drawing No(s).: I MCR-NV- 121-3 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date October 3 ,201*L Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

 .. 7z-..e27. 2zLto,                     Z4Q"7                    and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section.XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Own,'s Report. Furthermore, neither 9A Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro Tr connected with this inspectio JF Swan - Commi.sion .NBI 1473-NC1524, N-I Inspector's Sigriature-ý / National Board, State, Province, and Endorsements Dat 20/ / Dat 2011

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner Duke Energv Carolinas L Date :9/23/2011 Charlotte, NC, 28201 Sheet I of 2 526 South Church Street Address
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1794757-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 10 1 A Address Expiration Date: I"f

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME Il 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section X1 used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCR-NV-1206 Duke Energy 20744 N/A ..N/A N/A Removed No IMCR-NV-1206 Duke Energy 37612 -N/A . N/A N/A Installed No
7. Description of Work Retplaced Component/Part/Appurtenance Additional Description R -placed snubber and it's bolting material on hanger IMCR-NV-1206
8. Tests Conducted: Hydrostatic F Pneumatic Fr Nominal Operation Pressure rT Exempt F Other F" Pressure PSI Test Temp. F O__

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 3 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1554-01.02 Support/Restraint Sketch/Drawing No(s).: IMCR-NV- 1206 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on.NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist " Date September 23 ,20 1 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

  • Connecticut have inspected the components described in this Owner's Report during the period r7- -/ to - .and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's *eport. Furthermore, neither th Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o nnected with this inspection.

'.JF Swan      7 [-Commissions Inspector's Signature" NBI 1473-NC 1524, N-I National Board, State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X!

1. Owner fliik~ Pnpi-crv C~~rn1inne 1.1 LC Date 9/23/2011 Duke Enerov Carolinas L 526 South Church Street. Charlotte, NC, 28201 Sheet :I of .2 A AA..
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1794773-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 . ... . . N/A Address Expiration Date:...

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME I1 I 971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed. or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCR-NV-1201 Duke Energy 20576 N/A N/A N/A Removed No 1MCR-NV-1201 :Duke Energy 37601 N/A N/A N/A Installed No

7. Description of Work Rep~laced Component/Part/Appurtenance Additional Description Re ~placed snubber and it's bolting material on hanger IMCR-NV- 1201
8. Tests Conducted: Hydrostatic " Pneumatic F Nominal Operation Pressure '- Exempt F Other F Pressure _ _PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVI CY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 3 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1554-01.02 Support/Restraint Sketch/Drawing No(s).: I MCR-NV- 1201 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI, Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date September 23 ,2011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION [, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

.North Carolina                                                                 and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut                                                                    have inspected the components described in this Owner's Report during the period
  '7 - 7_/-Lto                          2,            I/      ...  , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising frorn4r connected with this inspection./

.JF Swan */            *t.                   _-            -7                                      Commissions NB l1473-NCI524, N-Inspector's Signature,     /                                                 National Board, State, Province, and Endorsements 9-R7 Date-7                                                   20 &-

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTMITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Enery Carolinas, LILC Date 9/27/2011 unC.rvile,20107 Sheet . of. 2 Address Fterthrlotte.

Chaersh 12700Sut

2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1794774-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date:

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASMElI 1971 Edition, Summerand Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCR-NV-1043 Duke Energy 19894 N/A zN/A N/A Removed No IMCR-NV-1043 Duke Energy 38527 N/A N/A IN/A Installed No

7. Description of Work Replaced Compbonent/Part/AIpurtenance Additional Description R eplaced snubber on hanger 1MCR-NV- 1043
8. Tests Conducted: Hydrostatic I" Pneumatic F Nominal Operation Pressure fT Exempt 1F Other F Pressure PSI Test Temp. -°F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 15 System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1554-01 .02 Support/Restraint Sketch/Drawing No(s).: IMCR-NV- 1043 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp :N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date September 27 _,20L. Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

.Connecticut                                                                 have inspected the components described in this Owner's Report during the period
*     /    )   '7     1/'        to         '    ,         /( ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's ieport. Furthermore, neither the Inspe or nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o nnected with this inspection. JF Swan - ,,, _*- Commissions NBI 1473-NC 1524, N-I

             -       Inspector's Signature  "                                                   National Board, State, Province, and Endorsements Dro-)-

t D~9 te 20-/Z 20

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X!

1. Owner D.ke....... Caro na. L -L Date 10/1/2011 Duke EnerLyv Carolin 526 South Church Street, (Charlotte, NC, 28201 Sheet .1 of 2 A.uuress
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1794895-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 XKT A Address Expiration Date:

4. Identification of System ýNV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME III 192_L Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)
*MCR-INV-581                           Duke Energy                       20712                         N/A                        N/A                                N/A          Removed                        No
MCR-lNV-581 -Duke Energy 37600 N/A N/A N/A Installed No
7. Description of Work Re )laced Component/Part/Appurtenance Additional Description R eplaced snubber and it's bolting material on hanger MCR-INV-581
8. Tests Conducted: Hydrostatic F- Pneumatic F Nominal Operation Pressure F' Exempt F7 Other r'T Pressure ___PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1554-02.01 Support/Restraint Sketch/Drawing No(s).: MCR-INV-581 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist . Date October 1 )2011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of
Connecticut have inspected the components described in this Owner's Report during the period to.-a-
                                   //)                _/-/     ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's port. Furthermore, neither the spector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o cnnected with this inspection.

*JF Swan                                                                                    -,-Commissions NBI 1473-NC 1524, N-I n~scor'sSigntureNational                                         Board. State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Enerey Carolinas.I Ll LC Date 9/27/2011 526 South Church Street, Charlotte, NC, 28201 Sheet '1 of 2 Address
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 11794896-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Type Code Symbol Stamp:

Name Authorization No.: 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date:

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME III 19 71 Edition, 'Summer and Winter Addenda, *N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCR-NV-545 Duke Energy .19900 N/A ;N/A N/A Removed No IMCR-NV-545 Duke Energy 38410 :N/A 'N/A N/A Installed No
7. Description of Work Replaced Component/Part/A1purtenance Additional Description Replaced snubber on hanger I MCR-NV-545
8. Tests Conducted: Hydrostatic F Pneumatic r" Nominal Operation Pressure '- Exempt F: Other r- Pressure: PSI Test Temp. O_°F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1 554-01.00 Support/Restraint Sketch/Drawing No(s).: IMCR-NV-545 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist "Z7KS * ..L.. Date September 27 , 201. Owner or Owner's Designee, Title I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

Connecticut have inspected the components described in this Owner's Report during the period
      -,ý      1[           to 92      .'.     ' 7 .../,   / and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither tif Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fromo connected with this inspectio

.JF Swan    L                           /7                   .                                 Commissions NB11473-NC1524, N-I Inspector's Signature     1                                               National Board, State, Province, and Endorsements Dateu-                                                  20_J

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas, LL LC Date 6/30/201 526 South Church Street, Charlotte, NC, 28201 Sheet '1 of 2
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1794903-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 . - \I/A Address Expiration Date: '"'
4. Identification of System CA - Auxiliary Feedwater
5. (a) Applicable Construction Code ASME III 192., Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCA-CA-411 Duke Energy 16091 N/A N/A N/A Removed No IMCA-CA-41 I Duke Energy 37875 N/A N/A N/A Installed No
7. Description of Work Ad d New Comnonent/Part/Angurtenance/Weld Additional Description R eplaced snubber on hanger I MCA -CA-41 I
8. Tests Conducted: Hydrostatic F Pneumatic F Nominal Operation Pressure F Exempt F* Other F Pressure PSI Test Temp. __ IF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 6 in. (nominal) System Class: ASMEClass2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1592-01.00 Support/Restraint Sketch/Drawing No(s).: 1MCA-CA-411 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-CAN-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed I.FL Grass, Quality Assurance Technical Specialist Date Juneb 30 ,20.1I Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period 6 -to 2 - *,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the I pector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. JF Swan  ; 2 Commissions NB11473-NC1524,NI inspetor's Signature National Board, State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Enerv Carolinas.I LILC Date 7/13/2010 526 South Church Street, 4Charlotte, NC, 28201 Sheet I ýof 2 Address
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1794904-01 Address Work Order # (or Repair/Replacement Organization P.O. No.,.lob No., etc.)
3. Work Performed by Duke Enerzy Carolinas, LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street. Charlotte, NC 28201-1006 *KI/A Address Expiration Date:

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME III 1971. Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yesor NO)

INCA-NV-306 ;Duke Energy 20531 N/A IN/A N/A Removed No 1NCA-NV-306 :Duke Energy .37050 :N/A :N/A N/A Installed No

 . . . . . . . .* .. * *... . . . ..i :....
7. Description of Work Rer ~UOLAt S..AJIIALfl)Ik'~,flhL~ u an u n.IJIJUL I. flUE L'.~L, Additional Description Retplaced snubber and it's bolting material on hanger I MCA-NV-306
8. Tests Conducted: Hydrostatic F Pneumatic FT Nominal Operation Pressure FT Exempt F Other F" Pressure __

PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 3 . in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1556-01.01 Support/Restraint Sketch/Drawing No(s).: I MCA-NV-306 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NB-306-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date July 13 ,20i. - Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NorthCarolina .and employed by Hartford Steam Boiler Inspection and Insurance Company of iConnecticut have inspected the components described in this Owner's Report during the period

.i 'zz2.".* /i*                  to              .,and               state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owne Report. Furthermore, neither the Inspecto or his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro connected with this inspection. Commissions NC 1524, N-I Inspector's Signature ....... National Board. State. Province. and Endorsements ter-3 2

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Proisions of the ASME Code Section XI

1. Owner Duke Enery Carolinas, LILC Date *2/28/2011
                  ~2ij S~A,1th t2hiir~2h 5~tre~et flharlnttn NC> 2R201 Sheet     I        of 2 Address
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1794905-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No.. etc.)
3. Work Performed by Duke Energy Carolinas, LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A

4. Identification of System :ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edlition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

I MCA-ND-272 !Duke Energy :14925 N/A N/A N/A Removed No 1MCA-ND-272 .Duke Energy .37591 N/A . :N/A N/A Installed No

7. Description of Work Replaced Component/Part/Appurtenance Additional Description R eplaced snubber and it's bolting material on hanger I MCA-ND-272.
8. Tests Conducted: Hydrostatic F Pneumatic F' Nominal Operation Pressure F- Exempt [ Other r" Pressure PSI Test Temp. _ OF_ .

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 8 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: :MCFD-1561-01.00 Support/Restraint Sketch/Drawing No(s).: 1MCA-ND-272 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date February 28 20 11. Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

                     /ý...**,   t                                  and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this On' Rert. Furthermore, neither the Ins t his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fm connected with this inspection. JF Swan Commissions NC 1524, N- I Inspector's Signature National Board. State, Province. and Endorsements

                                                                /

I

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas, LILC Date 9/8/2011
                  .26.S..th........Street'                  Charlotte, NC. 28201                                                      Sheet   i         of. 2 526 South Church Street  A AA.-,
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1794907-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by, Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A
4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME III 197t Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed ition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) 'N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MC1683-NV.04-R33 Duke Energy 21166 N/A .N/A N/A Removed No 1MC1683-NV.04-R33 Duke Energy 38395 .. N/A .N/A . N/A Installed No
7. Description of Work Rey laced Component/Part/Appurtenance Additional Description R_eplaced snubber on hanger 1MC1683-NV.04-R33
8. Tests Conducted: Hydrostatic I Pneumatic r" Nominal Operation Pressure FT Exempt FT Other I Pressure _ :_PSI Test Temp. _ :OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet '2 of 2 Component Line Size: 2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1554-03.Ol Support/Restraint Sketch/Drawing No(s).: I MCI 683-NV.04-R3-3 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on N IS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date September 8 ,,20 Hi Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

 ýConnecticut                                                                   have inspected the components described in this Owner's Report during the period to                                   and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Ins ctor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. Commissions NB11473-NC1524, N-Inspec-tor'sSignature .National Board, State, Province, and Endorsements Date r  ?-I;. ,21

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energv Carolinas.I LILC Date 9/6/20 11 526 South Church A*IA ....

Street, Charlotte, NC, 28201 Sheet I of .2

2. Plant McGuire Nuclear Station Unit I Name 12700 Haiers Ferry Road, Huntersville, NC 28078 1794908-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas. LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street. Charlotte, NC 28201-1006 .... "/AT Address Expiration Date:
4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME II 1921 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) 'N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MC1683-NV.01-R16 Duke Energy 20757 N/A N/A N/A Removed No 1lMC1683-NV.01-R16 Duke Energy 38444 N/A .. N/A N/A Installed No
7. Description of Work ReT,La.,IVu ý..,LLLJ.JVAI'Alu iOl.~fI~U LLLL Additional Description Reeplaced snubber on hanger 1MC-1683-NV.0l-R16
8. Tests Conducted: Hydrostatic F Pneumatic F' Nominal Operation Pressure IF Exempt F Other F Pressure _ PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner . .uk E-rv
                         .... C.....na..       L LC LI--                                                                   Date 10/1/2011 Duke Energv C olin 526 South Church Street, Charlotte, NC, 28201                                                           Sheet 1             of :2 Adduress
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville,-NC 28078 1922157-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Eneray Carolinas, LLC Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 N/A Address Expiration Date:

4. Identification of System CF - Feedwater
5. (a) Applicable Construction Code ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped ComponentName of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCR-CF-402 Duke Energy 33791 N/A IN/A N/A Removed No I MCR-CF-402 Duke Energy 38451 N/A ":N/A N/A Installed No
7. Description of Work Rep laced Component/Part/Appurtenance Additional Description Re~placed snubber on hanger IMCR-CF-402
8. Tests Conducted: Hydrostatic I Pneumatic " Nominal Operation Pressure F" Exempt F Other F Pressure PSI Test Temp.: OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 16 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1591-01.01 Support/Restraint Sketch/Drawing No(s).: 1MCR-CF-402 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist \Z -*,4-. Date October I - 20 I1 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

.North Carolina                                                                and employed by Hartford Steam Boiler Inspection and Insurance Company                            of Connecticut                                                                    have inspected the components described in this Owner's Report during the period 2
  "/- ~,~   "2,7.Z    .         to           -                      and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthetrnore, neith he Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro or connected with this inspec JF SwCommissions NBI1473-NC1524, N-I SInspector's Signatul- - National Board. State, Province, and Endorsements Da e/ /DL - 20//

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas, LILC Date 9/20/2011 526 South Church Street, Charlotte, NC, 28201 Sheet I1 of 2 lAUUI~~
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 .1922362-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A
4. Identification of System SM - Main Steam
5. (a) Applicable Construction Code ASME III 192L Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edlition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCA-SM- IDuke Energy .22391 N/A N/A N/A Removed No 1MCA-SM-11 .Duke Energy 37890 N/A .N/A .N/A Installed No
7. Description of Work Replaced Component/Part/Appurtenance Additional Description Replaced snubber on hanger 1MCA-SM - I11
8. Tests Conducted: Hydrostatic r Pneumatic r- Nominal Operation Pressure F" Exempt F Other F Pressure _ PSI Test Temp. 'F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 :of 2 Component Line Size: 42 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: :N/A Flow Diagram No(s).: MCF.D- 1 593-01.00 Support/Restraint Sketch/Drawing No(s).: IMCA-SM- I I Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist , Date September 20 -, 20 1 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

 -Connecticut                                                                   have inspected the components described in this Owner's Report during the period
  .7z9._.2Ž".//zto                     "L-                  ...      and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the I ector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or onnected with this inspection. JF SwanCommissions NBI 1473-NC 1524, N-I SInspector's Signature National Board, State, Province, and Endorsements DateQ. - ' " ,20 IP

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X!

1. Owner Duke Ener*v Carolinas, LILC Date 9/25/2011 526 South Church Street. Charlotte, NC, 28201 Sheet I of 2 A AA.,
2. Plant McGuire Nuclear Station Unit 1 Name
                                                                                                                    .1922368-01 12700 Hagers Ferry Road, Huntersville, NC 28078 Address                                                                 Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: 'N/A Authorization No.: :N/A 526 South Church Street. Charlotte. NC 28201-1006 Address Expiration Date: N/A
4. Identification of System CA- Auxiliary Feedwater
5. (a) Applicable Construction Code ASME III 1971. Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-CA-432 Duke Energy 20592 N/A :N/A N/A Removed No IMCA-CA-432 Duke Energy 38408 N/A N/A N/A Installed No

7. Description of Work Revlaced Component/Part/Appurtenance Additional Description Replaced snubber and it's bolting material on hanger IMCA-CA-432
8. Tests Conducted: Hydrostatic ' Pneumatic F Nominal Operation Pressure rI Exempt 5 Other F- Pressure PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 6 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1592-01.00 Support/Restraint Sketch/Drawing No(s).: IMCA-CA-432 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on N IS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist -Z. i,,.- Date September25 201L Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by :Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

 ....l 7-2 ...- ///.....         to      9 - 2 &-//,                 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Own, r's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro or connected with this inspec n. JF Swan -. - Commissions NBI 1473-NC 1524, N-I inspector's Sig~turZ National Board. State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

1. Owner Duke Enerqv Carolinas. LL C Date 10/1/2011 526 South Church StreetrCharlottea, NC 28201 Sheet I :of 2 Address
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1922384-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Type Code Symbol Stamp:

Name Authorization No.: 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date:

4. Identification of System ýNV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME III 193_L Edition, Summer and Winter Addenda, :N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

MCR-1NV-943 Duke Energy 21522 N/A ýN/A N/A Removed No

MCR-1NV-943 Duke Energy 38411 N/A N/A N/A Installed No
 ....i                   ..     . ..                                                    . .          ..      . I        ..
7. Description of Work Renlaced Comnonent/Part/Annurtenance Additional Description R -placed snubber and it's bolting material on hanger MCR-1NV-943
8. Tests Conducted: Hydrostatic F' Pneumatic r- Nominal Operation Pressure rI Exempt F Other fI Pressure PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTMTY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 ýof'2 Component Line Size: 2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1554-01.00 Support/Restraint Sketch/Drawing No(s).: MCR-INV-943 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist  %*JH

  • Date October 1 , 20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Hartford Steam Boiler Inspection and Insurance Company of
'North Carolina                                                                and employed by                                                                                    o

[Connecticut have inspected the components described in this Owner's Report during the period 7 WL7- to Zz" Z.--/ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' eport. Furthermore, neier the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from r onnected with thiinsion. IFSwan /',* -..-

  • Conmmisions NBI 1473-NC1524, N-I National Board, State. Province, and Endorsements ID Inspector's Signatur/r Date.U /0 20YL

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas, LI CDate 8/8/2011 526 South Church Street. Charlotte, NC, 28201 Sheet? 1 of 2 Atd'ess
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 .1922396-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas. LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A

4. Identification of System SM - Main Steam
5. (a) Applicable Construction Code ASME Iii 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCA-SM-103 Duke Energy 15827 N/A :N/A N/A Removed No
IMCA-SM-103 'Duke Energy 37568 N/A N/A N/A Installed No 1MCA-SM-103 'Duke Energy 16549 . N/A N/A Removed No 1MCA-SM-103 Duke Energy .38108 N/A N/A N/A Installed No
                            . . ..      ..                 . . . . . . .. ..                    . .. i .- . . . .  . .  . . ..... . l..:. .... . . . ... .   .     .      .     .. . . .    .    .
7. Description of Work Ret ,laced Component/Part/Appurtenance Additional Description Reeplaced snubbers on hanger IMCA-SM-1 03.
8. Tests Conducted: Hydrostatic F Pneumatic F Nominal Operation Pressure FI Exempt F Other F7 Pressure _PSI Test Temp. " -.OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 ýof 2 Component Line Size: 42 'in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1 593-01.00 Support/Restraint Sketch/Drawing No(s).: 1MCA-SM- 103 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-SMA-003 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date August 8 ,2011. Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION [, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North carolina .... and employed by Hartford Steam Boiler Inspection and Insurance Company of

Connecticut have inspected the components described in this Owner's Report during the period to &- /,and
                                                  /Z                   state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. IJF Swan ,, CIOo',d,-Lf-... NBI Commissions* 1473-NC1524, N-I Inspector's Signaturý 1117 National Board, State, Province, and Endorsements Da .- 201/

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTMITY As Required by the Provisions of the ASME Code Section Xi Date 8/8/2011

1. Owner Duke Ener*_v Carolinas. LI L LC Duke Energv Carolin Sheet 1 of 2 526 South Church Street, ICharlotte, NC, 28201 A* ....

I AddreSS

2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1922401-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Enemy Carolinas, LLC Type Code Symbol Stamp: 'N/A Name Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A
4. Identification of System SM - Main Steamr
5. (a)Applicable Construction Code ASME II1 197L Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCA-SM-75 Duke Energy 176 N/A NN/A Removed No 1MCA-SM-75 Duke Energy 38106 N/A N/A N/A Installed No 1MCA-SM-75 Duke Energy 16033 ,N/A N/A N/A Removed No 1MCA-SM-75 Duke Energy 38107 N/A IN/A 'N/A Installed No
.......' . . .. . ... . . . ... . . ..~ * ~~~~...
7. Description of Work Replaced Component/Part/Appurtenance Additional Description Replaced snubbers on hanger 1MCA-SM-75.
8. Tests Conducted: Hydrostatic F Pneumatic F Nominal Operation Pressure F Exempt P Other I- Pressure _ PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of . 2 Component Line Size: 42 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: :N/A Flow Diagram No(s).: MCFD-1593-01.03 Support/Restraint Sketch/Drawing No(s).: IMCA-SM-75 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-SMA-004 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed TL Grass, Quality Assurance Technical Specialist Date August 8 ,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

North Carolina .andemployed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period
   "          -               to             L-(              , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Insp tor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. f iJF Swan 9 ,l Inspectoes Signature

                                                  *      'Comrn                                         isions NB 1473-NC 1524, N-I National Board, State, Province, and Endorsements Date                                                  20_Z

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duk ~
                                           ....         Carolin.....             L LI--                                                                                                       Date 9/28/2011 Duke Energv Carolin 526 South Church Street. (Charlotte, NC, 28201                                                                                                                  Sheet            1        of 2 A ,iino,
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Halers Ferry Road4 Huntersville, NC 28078 '1922405-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A
4. Identification of System :NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME III . 19.71, Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) }N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) iMCR-INV-966 Duke Energy 21513 N/A N/A .. N/A Removed No IMCR- 1NV-966k~ ~
                ~......... ......       ~ ..Duke
                                      ....       .. ~
                                                    . ......Energy
                                                              ~ ... ...                                                        '38403                          N/A                       N/A                                          N/A        Installed                     No
                  .... . . .               ':!! .. .            . .... . ....            ~~~~~~~..
                                                                                                 .. ..... ... . . . . ..                                     l            .     . . . . .. .       .         . . ..          . . . .
                                                                                                                                           ----..               .I....                                               ...
                                                                  .. . .. . ... .. . .. . . . . . ..}. * .... . . . . ... . - * * . ..
7. Description of Work Replaced Component/Part/Appurtenance Additional Description Replaced snubber on hanger MCR- INV-966
8. Tests Conducted: Hydrostatic r. Pneumatic r Nominal Operation Pressure.. Exempt . OtherF Pressure !PSI Test Temp. O___F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 i of L2 Component Line Size: .2 "'in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: 'N/A Flow Diagram No(s).: ,MCFD-l1554-01.01 Support/Restraint Sketch/Drawing No(s).: IMCR-INV-966 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp :N/A Certificate of Authorization No. N/A Expiration Date ýN/A Signed fFL Grass, Quality Assurance Technical Specialist Date September 28  :, 201-Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

.North Carolina                                                            and employed by Hartford Steam Boiler Inspection and Insurance Company                               of Connecticut                                                               have inspected the components described in this Owner's Report during the period to :z2.izZ-,-'.toll -..and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspectio JF Swan -Commissions ýNBI 1473-NC1524, N-I

                    /Inspector's Signature                                                   National Board, State, Province, and Endorsements Dat         ....               _        _      __,20/

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner flhlkA Pnprciv flnrnhinn! II LC Date .6/27/2011 Duke Enerav Carolinas L 526 South Church Street.( Charlotte, NC, 28201 Sheet I of .2 526 South Church AAA- Street
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagers Ferry Road. Huntersville. NC 28078 1922412-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A

4. Identification of System CF - Feedwater
5. (a) Applicable Construction Code ASME III 19 7U'- Edition,: Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCA-CF-157 Duke Energy .15855 N/A N/A N/A Removed No IMCA-CF-157 Duke Energy 37883 N/A :N/A N/A Installed No
7. Description of Work Rev,laced Component/Part/Appurtenance Additional Description reiplaced snubber on hanger IMCA-CF- 157
8. Tests Conducted: Hydrostatic f Pneumatic r- Nominal Operation Pressure rT Exempt F Other F Pressure' PSI Test Temp. __

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 26 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-l591-01.01 Support/Restraint Sketch/Drawing No(s).: 1MCA-CF- 157 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-CFC-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist A Date June 27 ,20_1l Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of
.Connecticut                                                                have inspected the components described in this Owner's Report during the period
            .                 to"           -         7        , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither# Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro r connected with this inspecti FCommissions NB 11473-NC 1524, N-I DNational Board, State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTMITY As Required by the Provisions of the ASME Code Section XI

1. Owner fliik~ Fnpi-ov Cnrnlina'~ Ti LC Date 9/20/2011 Duke Ener- C olinas L 526 South Church Street_Charlotte, NC. 28201 Sheet i of .2 AAA.
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1922414-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC N/A Name Type Code Symbol Stamp:

Authorization No.: -N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A

4. Identification of System SM - Main Steam
5. (a) Applicable Construction Code ASME 111 19.71. Edition, 'Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s):N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-SM-108 :Duke Energy 15857 N/A N/A N/A Removed No 1MCA-SM-108 Duke Energy 38450 N/A N/A N/A Installed No N/A Reoe No IMCA-SM-108 Duke Energy 19911 N/A N/A N/A Removed No

1MCA-SM-108 Duke Energy 37886 :N/A " N/A N/A Installed Yes
7. Description of Work RepIlaced Component/Part/Appurtenance Additional Description Re*placed snubbers on hanger 1MCA-SM-108
8. Tests Conducted: Hydrostatic - Pneumatic - Nominal Operation Pressure F Exempt [ Other F Pressure __PSI Test Temp. O_°F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of :2 Component Line Size: 34 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1593-01.03 Support/Restraint Sketch/Drawing No(s).: ]1MCA-SM-108 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist - Date September 20 201*L Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

.Connecticut                                                                  have inspected the components described in this Owner's Report during the period S*      7..T1// to             0        a6                  and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the spector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from/ connected with this inspection. JF Swan 42 z-r . I-, , y  :*Commissions NBI 1473-NC 1524, N-I

           /   /    Inspector's Signature'   .1*                                                 National Board, State, Province, and Endorsements I

o I S.hee FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

1. Owner Duke Energy Carolinas, LLC Date 9/30/2011 526 South Church Street, Charlotte, NC, 28201 Sheet 1 of 2 A
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1922418-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A

4. Identification of System BB - Steam Generator Blowdown Recycle
5. (a) Applicable Construction Code ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed ition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped p Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCR-BB-663 :Duke Energy 19540 N/A N/A N/A Removed N.o IMCR-BB-663 Duke Energy .38404 N/A N/A N/A Installed No
7. Description of Work Re )laced Component/Part/Appurtenance Additional Description R eplaced snubber on hanger IMCR-BB-663
8. Tests Conducted: Hydrostatic F Pneumatic rT Nominal Operation Pressure F Exempt FF Other F Pressure. PSI Test Temp. _ '

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of Component Line Size: .2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1580-01.00 Support/Restraint Sketch/Drawing No(s).: IMCR-BB-663 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-MC-i 190-BB.9.1 Applicablc Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist \j 42L. Date September 30 2011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

ýNorth Carolina                                                                  and employed by :Hartford Steam Boiler Inspection and Insurance Company                             of NorthCaolinae
-Connecticut                                                                   .have     inspected the components described in this Owner's Report during the period
*.2--72.- 2L/."-.,/          .. to '            "         ,         and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither the Wpector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. JF Swan (. -,Commissions NBI 1473-NC1524, N-I I/nspector's Signatu /National Board, State, Province, and Endorsements te0

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X!

1. Owner Duke Enerev Carolinas, LILC Date I0/1/2011
                         ...    ......      ..... r.h        .. t ... t    ..h ....... 1   & 28201...

Sheet I of 2 Address

2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry R oad, Huntersville, NC 28078 1922422-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Enermy Carolinas, LLC Type Code Symbol Stamp:

Name Authorization No.: 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date:

4. Identification of System Nv -'Chemical and Volume Control
5. (a) Applicable Construction Code ASME 111 1971 Edition, Summer and Winter Addenda, N/A Code Case.

(b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) 'N/A

6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

'IMCR-NV-1048 'Duke Energy 20492 N/A N/A N/A Removed No

.IMCR-NV-1048                           ,Duke Energy                                          38528                       :NA                       N/A                                  N/A       Installed                        No
7. Description of Work Replaced Component/Part/Appurtenance Additional Description :R -placed snubber on hanger I MCR-NV- 1048
8. Tests Conducted: Hydrostaticc Pneumatic r Nominal Operation Pressure Exempt Other F O Pressure PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 3 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1554-01.02 Support/Restraint Sketch/Drawing No(s).: I MCR-NV- 1048 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements- of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date October I 20 i1. Owner or Owner's Designee. Title . CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Hartford Steam Boiler Inspection and Insurance Company of

.North Carolina                                                                and employed by                                                                                   o
.Connecticut                                                                   have inspected the components described in this Owner's Report during the period to                                  and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o connected with this inspection. JF Swan ]/Commissions NB 11473-NC 1524, N-I Inspector's Signature JNational Board. State, Province, and Endorsements Date*/ / ) /,20-L" ". .

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner .uk... ..... Car li...... . "L I--I.C Date .10/3/2011 Duke Energv Carolin Ll 526 South Church Street, Charlotte, NC, 28201 Sheet I1 of 2 Address
2. Plant McGuire Nuclear Station Unit i Name 12700 Hapers Ferry Road, Huntersville, NC 28078 1922423-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A
4. Identification of System NC - Reactor Coolant
5. (a) Applicable Construction Code ASME III 19 71. Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edlition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)
lMCR-NC-574 Duke Energy 20512 N/A ?N/A N/A Removed No T1MCR-NC-574 Duke Energy 38399 :N/A . N/A N/A Installed No
                                                                                                           .. .        .. . . I. s ..     . . .  .
7. Description of Work Replaced Component/Part/Appurtenance Additional Description re placed snubber on hanger I MCR-NC-574
8. Tests Conducted: Hydrostatic I Pneumatic r Nominal Operation Pressure F Exempt F7 Other r Pressure __ PSI Test Temp. O_°F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: *2 in. (nominal) System Class: ASME Class I Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-l 553-02.00 Support/Restraint Sketch/Drawing No(s).: iMCR-NC-574 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist -,",,* 4 Date October 3 ,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

.North Carolina                                                              and employed byHartford Steam Boiler Inspection and Insurance Company of Connecticut                                                                 have inspected the components described in this Owner's Report during the period to-
                               "/     /       "and                    state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither th spector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fryh or connected with this inspection IJF Swan(] 0 ' ',. . ,. _..--- Commissions NBI 1473-NC1524, N-I Inspector's Signature / ' - National Board, State, Province, and Endorsements D24(l 201//

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1 I. Owner Duke Enemyv Carolinas. LLC _ Date 9/19/2011 526 South Church Street. Charlottea, NCt 2820 I of 2 Address Sheet

2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1922427-01 Address Work Order # (or Repair/Reptucement Orgati7ition P.O. No.. Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date:

4. Identification of System FW - Refueling Water
5. (a) Applicable Construction Code ASME IIl 191L Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected. ASME Code Name of Manufacturer National Other Year Removed. or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-FW-121 Duke Energy 15118 N/A N/A N/A Removed N-2 IMCA-FW- 121 Duke Energy 37871 N/A N/A N/A Installed No

7. Description of Work Replaced Component/Part/Appurtenance Additional Description Replaced snubber on hanger IMCA-FW-121 -
8. Tests Conducted: Hydrostatic F Pneumatic F Nominal Operation Pressure F" Exempt F7 Other r- Pressure PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet of 2 Component Line Size: 24 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1571-01.00 Support/Restraint Sketch/Drawing No(s).: IMCA-FW-12 I Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data RePorts to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist , Date September 19 ,201i 1 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of lConnecticut have inspected the components described in this Owner's Report during the period i 7

      '/L   .  '- -/     /         to  .                               and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective.

measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injuty or property damage or a loss of any kind' arising from connected with this inspection. JF Swan -7Commissions NBI 1473-NC1524, N-I SInspector's Signature National Board. State. Province. and Endorsements Date 9" 2Vi) 2071

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas, LILC Date '9/15/20 1 "

526 S outh Church Street, Charlotte, NC, 28201 Sheet I of 2 Adoress

2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hapers Ferry Road, Huntersville, NC 28078 1922428-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No.. etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 ".,TjA Address Expiration Date: i'j
4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component of anufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCA-ND-281 Duke Energy 14788  ::N/A ;N/A ýN/A i Removed No lMCA-ND-281 Duke Energy 38376 N/A N/A N/A Installed No IMCA-ND-281 Duke Energy :20735 N/A . N/A N/A Removed No IMCA-ND-281 Duke Energy . 38377 N/A :N/A N/A Installed No
7. Description of Work Re )]aced Component/Part/Appurtenance Additional Description Rieplaced snubbers on hanger 1MCA-ND-281
8. Tests Conducted: Hydrostatic " Pneumatic r" Nominal Operation Pressure F" Exempt [ Other F Pressure _ PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 8 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1561-01.00 Support/Restraint Sketch/Drawing No(s).: IMCA-ND-281 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date September 15 ,20 L Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

 .Connecticut                                                               have inspected the components described in this Owner's Report during the period
                     'i'.-i  to                                ,-and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Ins ctor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o onnected with this inspection.

,JF Swan                                 -Commissions                                          ;                    NB1 1473-NC 1524, N-I lnsctors Signature In                                                                         National Board, State, Province, and Endorsements D          /,t               !92

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner . . ....... Ca-rol.... LC as. LI--

L Date 7/19/2011 Duke Energv Carolinas 526 South Church Street. Charlotte, NC, 28201 Sheet 1 of 2 AAAr~~,

2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1922433-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street. Charlotte. NC 28201-1006 Address Expiration Date: 1NI,*

4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME III 197L Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-ND-297 Duke Energy 15697 N/A N/A N/A Removed No IMCA-ND-297 :Duke Energy 38099 N/A "'N/A N/A Installed No

7. Description of Work Rep placed CosnuonhentPart/A1ourten-ance Additional Description Re~placed snubber on hanger IMCA-ND-297.
8. Tests Conducted: Hydrostatic I" Pneumatic F Nominal Operation Pressure rI Exempt F7 Other "" Pressure PSI Test Temp. __

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 12 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: :N/A Flow Diagram No(s).: MCFD-1561-01.00 Support/Restraint Sketch/Drawing No(s).: IMCA-ND-297 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist N'c . Date July191,20 IL Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

.North Carolina                                                         and employed by Hartford Steam Boiler Inspection and Insurance Company                            of Connecticut                                                             have inspected the components described in this Owner's Report during the period y....7i  *i*.Ž .. / ~to -i2.Z.2-:L*{./.... and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Own r's Report. Furthermore, neither the hspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising frof or connected with this inspection.

 .IF Swa,                '/           ..                                                    Commissions NBI 1473-NC 1524, N-I Inspector's Signature                                                  National Board. State, Province, and Endorsements 20.1//

I Da&'

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

1. Owner Duke Energy Carolinas. LI L LC Date 9/19/2011 Duke Ener2v Carolinas Sheet of .2 526 South Church Street, Charlotte, NC, 28201 AuurIss
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 '1922445-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A
4. Identification of System FW - Refueling Water
5. (a) Applicable Construction Code ASME III 191L Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-FW- 118 'Duke Energy 14752 N/A N/A N/A Removed No 1MCA-FW- 118 Duke Energy 37842 .N/A N/A N/A Installed No

7. Description of Work Rep*laced ComDonent/Part/Appurtenance Additional Description Reeplaced snubber on hanger IMCA-FW- 118
8. Tests Conducted: Hydrostatic [7 Pneumatic [" Nominal Operation Pressure [7 Exempt P Other FI Pressure __PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 4 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 157 1-0 1.00 Support/Restraint Sketch/Drawing No(s).: IMCA-FW- 118 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A 4 Signed FL Grass, Quality Assurance Technical Specialist -*_ ,zgt, Date :September 19 , 201l.l Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Nqorth Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

ýConnecticut                                                                have inspected the components described in this Owner's Report during the period
  -*--      2      L~to                  ?                // , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the *spector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. IF Swan A ;Commissions nNB1 1473-NC1524, N-I Inspector's Signature '/ National Board, State, Province, and Endorsements Date9 20-L1

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

1. Owner Duke Enerav Carolinas. LILC Date 19/8/2011 2

526 South Church Street, (Charlotte, NC, 28201 Sheet 1 of

                                /Address
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1922446-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC N/A Type Code Symbol Stamp:

Name Authorization No.: :N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A

4. Identification of System FW - Refueling Water
5. (a) Applicable Construction Code ASMEIm 192L Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) IN/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-FW-120 :Duke Energy 20666 N/A IN/A N/A Removed No

Duke Energy .38378 NA :N/A Installed N__o IMCA-FW-120
                           ..    .  .  .  ..    ..              i ..                                                 * .. ..  . *..                . .
7. Description of Work Rep)laced Component/Part/Appurtenance Additional Description Retplaced snubber on hanger IMCA-FW- 120
8. Tests Conducted: Hydrostatic IF Pneumatic r" Nominal Operation Pressure F' Exempt FT Other Fr Pressure PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 4 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: 'N/A Flow Diagram No(s).: MCFD- 157 1-0 1.00 Support/Restraint Sketch/Drawing No(s).: I MCA-FW-120 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date September 9 20 1 Owner or Owner's Designee, Title / " CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

,North Carolina                                                               and employed by Hartford Steam Boiler Inspection and Insurance Company of
'Connecticut                                                                  have inspected the components described in this Owner's Report during the period to        -                       ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Insp or nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fromI connected with this inspection.

.JF Swan     I/jo       -'             .    /*c        A-                                         Commissinno        NBI1473-NC1524, N-I Inspector's Signature       d-q                                              National Board. State, Province, and Endorsements Dateo                                                   20-9 Date("

7 2011

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Enerey Carolinas. LILC Date :6/30/2011 526 South Church Street, Charlotte, NC, 28201 Sheet of 2
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1922447-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A
4. Identification of System FW - Refueling Water
5. (a) Applicable Construction Code ASME III 197L Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section X! Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCA-FW-126 Duke Energy 20804 'N/A IN/A N/A Removed No IMCA-FW-126 Duke Energy .37876 N/A :N/A N/A Installed No
7. Description of Work Ad I New Component/Part/Appurtenance/Weld Additional Description Re*placed snubber on hanger IMCA-FW-126.
8. Tests Conducted: Hydrostatic F Pneumatic r Nominal Operation Pressure F' Exempt F Other r Pressure PSI Test Temp. _

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 24 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1571-0l .00 Support/Restraint Sketch/Drawing No(s).: IMCA-FW-126 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-FWA001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XL.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist NT .* Date June 30 ,20 1l Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

;North Carolina           'and                                                 employed by Hartford Steam Boiler Inspection and Insurance Company of
.Connecticut                                                               have inspected the components described in this Owner's Report during the period 22=Z                                              _Ztand state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described i this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither the Ins ctor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from* connected with this inspection. IJF Swan IIC (- '2-.9 Commi.*inn* .NB1I1473-NC 1524, N-I National Board, State, Province, and Endorsements Date(D- / " Inspector's Signature - 0. 2/0

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

1. Owner Duke Energy Carolinas, L LC Date '7/12/2011 526 South Church Street, (Charlotte, NC, 28201 Sheet I of 2 A AA
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1922449-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A

4. Identification of System FW - Refueling Water
5. (a) Applicable Construction Code ASME III 193L; Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)
.1MCA-FW-160              Duke Energy                      19552                       N/A                       /A                                 N/A        Removed                          No IMCA-FW-160              Duke Energy                      37874                       N/A                      N/A                                 N/A        Installed                        N__

IMCA-FW-160 Duke Energy 16541 N/A ýN/A N/A Removed No IMCA-FW-160 Duke Energy 37873 N/A :N/A N/A Installed No

7. Description of Work Re vlaced Component/Part/App~urtenance Additional Description Rieplaced snubbers on hanger IMCA-FW-160
8. Tests Conducted: Hydrostatic F" Pneumatic IF Nominal Operation Pressure F Exempt F Other r" Pressure PSI Test Temp. 0 OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 24 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-157l-01.00 Support/Restraint Sketch/Drawing No(s).: IMCA-FW- 160 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date 'N/A Signed FL Grass, Quality Assurance Technical Specialist Title

                                                                                                    --   */'         .i,2v                                     Date July 12         ,2011 Owner or Owner's Designee, CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of
 ..North Carolina                                                                   and employed by Hartford Steam Boiler Inspection and Insurance Company                             of
'Connecticut                                                                        have inspected the components described in this Owner's Report during the period to
                                      -. T_!/         R -i             , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither thef pector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro or connected with this inspection.

.JF Swan           *g[4Z,,Lt2...

Inspector's Signatul

                                               /.,y*                      p- I                          Commi-inne%NB11473-NC 1524, N-I National Board, State, Province, and Endorsements Datd                 7/-I 77w

__________________- ~1~~

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas, LIL-C Date '7/21/2011 526 South Church Street Charlotte, NC, 28201 Sheet .. of 2 A AA....
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Ha`4ere Ferry Road Huntersville. NC 28078 11922451-01 Address Work Order # (or RepairfReplacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date:  :'"'

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME III 19 71F Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) ;N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCA-NV-471 Duke Energy 21690 N/A ;N/A N/A Removed No 1MCA-NV-471 Duke Energy 38424 N/A N/A N/A Installed No MCA-V-47 .... .N/ Installed
                          ..* ... ...? ...-.. *. ..: . " "* " i .'.. .  .      . '   .i " . . .    "      . .. ." Z ..* I " . .' . ,     .. . ... *, . . .  ...  .  ..   . .. . .     .   . ..... .. . . . .
7. Description of Work Rei laced ComnonentlPart/Aonurtenance Additional Description R eplaced snubber and its bolting material on hanger IMCA-NV-471
8. Tests Conducted: Hydrostatic I" Pneumatic r" Nominal Operation Pressure I Exempt F' Other F Pressure _PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of"2 Component Line Size: 6 _ in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1555-02.00 Support/Restraint Sketch/Drawing No(s).: IMCA-NV-471 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NVD-003 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist t Date July 21 ,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

'Connecticut                                                                  have inspected the components described in this Owner's Report during the period T   zL2 -z/-....            :to ,7- -             /         ./ ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Insp tor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. JF Swan / *- - *"-*Z*7 ,,.,.,-,- --- - - Commissions NBI I473-NC1524, N-I Inspector' sSignature ' f National Board, State, Province, and Endorsements 20// 2L

     ! ei

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTMITY As Required by the Provisions of the ASME Code Section X!

1. Owner Duke Pner~v C~roIinn~ LI Date 7/21/2011 Duke Ener" Carolin L 526 South Church StreetrCharlotte, NC, 28201 Address Sheet I of 2
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers FerrY Road, l-untersville, NC 28078 1922452-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street. Charlotte, NC 28201-1006 Address Expiration Date: N/A
4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME Ill 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed ition with the 1999 and 2000 Addenda (c) Applicable Section Xl Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCA-NV-5522 Duke Energy 20519 N/A N/A N/A Removed No IMCA-NV-5522 Duke Energy 38418 N/A N/A N/A Installed No
7. Description of Work Rep~laced Component/PartlADRrurtenance Additional Description Replaced snubber and its bolting material on hanger 1MCA-NV-5522
8. Tests Conducted: Hydrostatic [T Pneumatic F- Nominal Operation Pressure Ir Exemp: F- Other I" Pressure PSI Test Temp. °OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 3 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-l 555-02.00 Support/Restraint Sketch/Drawing No(s).: IMCA-NV-5522 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NVS-004 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist * ,,/*.,a¢- Date July 21 ,20 11 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

      -/                       to                                  and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner'sIReport. Furthermore, neither the Insp tor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o onnected with this inspection." JF Swamn ,, A - ------ ommissions NBI'1473-NC1524, N-I INational Board, State, Province, and Endorsements Date 0 ,7 A-I,20-L

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

1. Owner fluke Fnerov C'~rnhit1R~ 1.1LC Date 7/19/2011 Duke Enerov Carolinas L 526 South Church Street_ ICharlotte, NC, 28201 Sheet 1 of 2 526 South Church Street AAA
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagers Ferry Road, Huntersville. NC 28078 1922553-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No.. etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street Charlotte, NC 28201-1006 Address Expiration Date:

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME HII 192+/-_ Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed ition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yea or No)

I MCA-NV-396 Duke Energy 21192 N/A N/A N/A Removed No IMCA-NV-396 Duke Energy 38076 N/A N/A N/A Installed No

7. Description of Work Replaced Coms nentbPart/Aimurtenance Additional Description placed snubber and its bolting material on hanger IMCA-NV-3 96.
8. Tests Conducted: Hydrostatic I- Pneumatic r- Nominal Operation Pressure F- Exempt F Other r- Pressure PSI Test Temp. °F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 4 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing NOWs): N/A Flow Diagram No(s).: MCFD- 1554-02.00 Support/Restraint Sketch/Drawing No(s).: I MCA-NV-396 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date July 19 - 20 11 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period q - , ,- it to / - and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his ployer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Ins or nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o connected with this inspection. JF Swan Commissions .NB11473-NC1524, N-I

                       -pector's Signature                                                         National Board. State, Province, and Endorsements Date                   -                              ,   20._&

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas, LILC Date 9/20/2011 526 S outh Church Street, Charlotte, NC, 28201 Sheet I of 2 Address
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1922571-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street. Charlotte, NC 28201-1006 Address Expiration Date: N/A

4. Identification of System SM - Main Steam
5. (a) Applicable Construction Code ASME III 19.71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda 1998 Ed on wi the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCA-SM-185 Duke Energy 22428 N/A N/A N/A Removed No IMCA-SM-185 Duke Energy 37884 N/A N/A N/A Installed No
7. Description of Work Reiplaced Component/Part/Appurtenance Additional Description Rteplaced snubber on hanger IMCA-SM- 185
8. Tests Conducted: Hydrostatic F Pneumatic F" Nominal Operation Pressure F Exempt [F Other F- Pressure PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 34 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1593-01.03 Support/Restraint Sketch/Drawing No(s).: 1MCA-SM-185 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist '-

  • Date September 20 201_.

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

         /Z               to                /                  and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the I pector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro .r connected with this inspection. JF Swan. Inspector's Signature F /National

                                                                                               -Commissions             NB11473-NC1524, N-1 Board, State, Province, and Endorsements Date 0           q               --   /                 , 2 0J/

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke F.ner~vv Carolinas LILC Date 7/25/2011 Duke Enerov Carolinas L 526 South Church Street. Charlotte, NC, 28201 Sheet 1I of 2 A AA-,
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagers Ferry Road, Huntersville. NC 28078 1922572-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas. LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street. Charlotte, NC 28201-1006 Address Expiration Date:

4. Identification of System SM - Main Steam
5. (a) Applicable Construction Code ASME III 191L Edition, Summer and Winter Addenda, N/A Code Case with the 1QQQ anid 90A0 Adcepndn (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed]iticon 1
                                                                                               ........ wit   .... 199 and.2000 ......       da (c) Applicable Section XI Code Case(s) N/A
6. Identification of Comn onents Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-SM-209 Duke Energy 15706 N/A .N/A N/A Removed No 1MCA-SM-209 Duke Energy 37882 N/A N/A N/A Installed No

7. Description of Work Replaced Component/Part/Appurtenance Additional Description Re placed snubber on hanger IMCA-SM-209
8. Tests Conducted: Hydrostatic r Pneumatic r- Nominal Operation Pressure r- Exempt P* Other rI Pressure .PSI Test Temp. O__

F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X!

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 42 - in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing NOWs): N/A Flow Diagram No(s).: MCFD- 1593-01.-03 Support/Restraint Sketch/Drawing No(s).: 1MCA-SM-209 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-SMA-004 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist ,- ,-ýDate July 25 ,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period I Z2. -// to - //, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector n his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owne s Report. Furthermore, neither tl nspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro r connected with this inspection Commissions ~~NBI1473-NC1524, N-I Dar T-S2/ SInspector's Signature" National Board. State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

1. Owner Duke Ener-av Carolinas LI LC -Date 10/16/2011 2

5 MthchuiarSre Address NuclearlStationC220 Sheet 1 of

2. Plant McGuire Nuclear Station Unit I Name 12700 H-agers Ferry Road, Huntersville, NC 28078 1930950-08 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No.. etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street. Charlotte. NC 28201-1006 Address Expiration Date: N/A
4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME IIll 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected. AS ME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

INV498 ITT Grinnell 73-8013-8-1 WR2426 V File# 1046 1976 Installed Yes __ _ _ _ _I _ _ _ _ _ __I __ _ _ _ _I _ [_ _ _ _ _ _ _ _ _ _ _1_ I___

7. Description of Work Replaced Component/Part/Appurtenance Additional Description Replaced bonnet on valve INV498 per EC 102955.
8. Tests Conducted: Hydrostatic r" Pneumatic r- Nominal Operation Pressure F Exempt f" Other F- Pressure PSI Test Temp. °F Description (Optional): test performed per procedure MP/0/A/7700/045.

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X!

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 6 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: MCFI-INV1O Flow Diagram No(s).: MCFD- 1554-03.01 Support/Restraint Sketch/Drawing No(s).: N/A Other Applicable Information (e.g., W.O. No.. EC No.) if not included elsewhere on NIS-2 Form: EC 102955 Apphcable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist 2S Date October 16 ,201-.1 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period q- a7 -L to./ -

                                              "7  /                 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the In pector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o connected with this inspection. JF Swan .A-,,,.....- - Commissions NBI 1473-NC1524, N-i Y- Inspector's Sinature /A' National Board. State. Province. and Endorsements I

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas. LL LC Date 10/14/2011 Duke Ener2v Carolinas Ll 526 South Church Street Charlotte, NC. 28201 Sheet 1 of 2 Address
2. Plant McGuire Nuclear Station Unit I Name 12700 Ha-gers Ferry Road, Huntersville, NC 28078 193095 1-14 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC "I'.
                                                                                                                            , 11 ^A. 0,*^   ý    ..... N/A Name                                                                   Y        AtU orizy    i  n No.ll:p Authorization No.:

526 South Church Street. Charlotte, NC 28201-1006 Address Expiration Date: t~"r'

4. Identification of System BB - Steam Generator Blowdown Recycle
5. (a) Applicable Construction Code ASME III 1921. Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected. ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCR-BB-501 Duke Energy N/A N/A N/A N/A Installed No

7. Description of Work Renlaced Component/Part/Appurtenance Additional Description Modified hanger IMCR-BB-501 per EC 100651
8. Tests Conducted: Hydrostatic F" Pneumatic F- Nominal Operation Pressure F" Exempt F Other -" Pressure PSI Test Temp. °F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1580-01.00 Support/Restraint Sketch/Drawing No(s).: IMCR-BB-501 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: EC100651 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date October 14 ,20 II Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

  /                             tto _,/Q      /7Z.            ," , andstate that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Ins ctor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from onnected with this inspection. JF Swan/ 0 1-Commissions NBI 1473-NC 1524,N-I

          "         Inspector's iSignature                       -National                                    Board. State, Province, and Endorsements Da           lb,_/                     _7               20_&

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTMTY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas, Li Date 10/14/2011 526 South Church Street. 4Charlotte, NC., 28201 Sheet -I of 2
2. Plant McGuire Nuclear Station unit 1 Name 1

12700 Hagers Ferry Road, Huntersville, NC 28078 193095 1-18 Address 1930951-18 Unit Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)

3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: e
4. Identification of System BB - Steam Generator Blowdown Recycle
5. (a) Applicable Construction Code ASME Ill 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCR-BB-507 Duke Energy N/A N/A N/A N/A Installed No
7. Description of Work Re Rlaced Component/Part/Appurtenance Additional Description W'orked hanger IMCR-BB-507 per EC 10065 1.
8. tests Conducted: Hydrostatic r Pneumatic F- Nominal Operation Pressure '- Exempt r- Other r- Pressure PSI Test Temp. _ O°F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions or the ASME Code Section Xi

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1580-0 i.00 Support/Restraint Sketch/Drawing No(s).: 1MCR-BB-507 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: EC100651 Applicable Manufacturer's Dam Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date October 14 )201 Owner or Owner's Designee. Title I I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

   /e)*      (n      I          to   ZeD -Z /7* /and                 state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither the lnsp tor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. JF Swan .Commissions NB 11473-NC 1524, N-I Inspector's Signature -National Board, State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

1. Owner Duke Energy CarolinasLI LC Date 9/28/2011 526 Smith church Street. 4Charlotte, NC, 28201 Sheet 1 of '2 526 South Church Street AAA
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Roadý Huntersville, NC 28078 1948066-09 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Type Code Symbol Stamp:

Name Authorization No.: 526 South Church Street. Charlotte. NC 28201-1006 Address Expiration Date:

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME III 19.7_L Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section X1 used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Comnonents Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

NV Piping Duke Energy N/A 37 N/A 1981 Installed Yes a a 4* 4 4 4 4

7. Description of Work Replaced Component/Part/Arrnurtenance Additional Description Rieplaced bolting in flange INVFE5300.
8. Tests Conducted: Hydrostatic " Pneumatic r" Nominal Operation Pressure F Exempt r" Other F" Pressure PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: MCFI-INV5 Flow Diagram No(s).: MiCFD-1554-01.Ol Support/Restraint Sketch/Drawing No(s).: MCSRD-NVA Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date September 28 ,20 H_ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period Kr S - // - to IF- 2, _ // , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XT. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from 17 connected with this inspection. JF Swan/I I .= =, . , J

                                               /1-7 J-' .     -- *--
                                                                #*ZCý *--Commissions NBI 1473-NC1524, N-I Inspector's Signature  f       -/                                              National Board, State, Province, and Endorsements D4e             D4                                      20-LI 201*

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X!

1. Owner Duke Energy Carolinas. LI LC Date 10/3/2011 52t S~niith Church Sfreet Charlotte, NC. 28201 Sheet I of 2 526 South Church Street
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagers Ferry Road, Huntersville. NC 28078 1952310-49 Address Work Order # (or Repair/Replacement Organization PO. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas. LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street. Charlotte, NC 28201-1006 Address Expiration Date:

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME IIl 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section Xl used for Repair/Replacement Activity 1998 EdLition with the 1999 and 2000 Addenda (c) Applicable Section Xi Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-NV-5609 Duke Energy 11003 N/A N/A N/A Removed No IMCA-NV-5609 Duke Energy 37068 N/A N/A N/A Installed No

7. Description of Work Renlaced Comnonent/Part/Annurtenance Additional Description Replaced snubber on hanger IMCA-NV-5609
8. Tests Conducted: Hydrostatic F' Pneumatic F" Nominal Operation Pressure '- Exempt fl Other F- Pressure PSI Test Temp. _ IF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 6 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1554-04.00 Support/Restraint Sketch/Drawing No(s).: I MCA-NV-5609 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date October 3 ,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period Sto. D , 4/-& and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither the spector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. IF Swan 0 Commissions NB131473-NC 1524, N-I Inspector's Signature / National Board, State, Province, and Endorsements ate 201//

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner fluik~ Fnerov Carolinas. L 1.1 LC -Date 10/5/2011 Duke Enerov Carolinas 526 South Church Street.( Charlotte, NC, 28201 Sheet I "of 2 526 South Church Street, Address
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1952541-07 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Type Code Symbol Stamp:

Name Authorization No.: 526 South Church Street. Charlotte. NC 28201-1006 Address E~xpiration Date:..

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME Ill 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCR-NV- 1190 Duke Energy N/A N/A N/A N/A Installed No

7. Description of Work Ad.d New Component/Part/Appurtenance/Weld Additional Description Rieattached item# 2 (2 x 2 x 1/4 Tube Steel) to item# 1 (3 x 3 x 1/4 Tube Steel) on hanger 1MCR-NV- 1190.
8. Tests Conducted: Hydrostatic [T Pneumatic -- Nominal Operation Pressure F" Exempt F Other F" Pressure PSI Test Temp. °F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1554-01.02 Support/Restraint Sketch/Drawing No(s).: I MCR-NV- 1190 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist \'*/,4, - Date October 5 ,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

   /                                 ....--

to I - (o" /Z and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or nnected with this inspection. JF Swan = -Commissions NBI 1473-NC 1524, N-I Date - SInspector's Signature 2o0 National Board, State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Enery Carolinas.I LI tC Date 10/25/2011
                  ~96 ~nuth Church Street    Charlotte. NC, 28201                                                    Sheet    I         of 2 526 South Church Street AAA
2. Plant McGuire Nuclear Station Unit i Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1956492-03 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Enermv Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street. Charlotte, NC 28201-1006 Address Expiration Date: N/A
4. Identification of System MNS - McGuire
5. (a) Applicable Construction Code ASME III 19971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built' Installed (Yes or No)

MNS Duke Energy N/A 44 N/A 1981 Installed Yes

7. Description of Work Re v1aced Comp~onent/Part/Appurtenance Additional Description re placed bolting, material on penetrations M461I
8. Tests Conducted: Hydrostatic F Pneumatic r Nominal Operation Pressure J7 Exempt F Other r" Pressure 'PSI Test Temp. _ O_

F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 6 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: N/A Support/Restraint Sketch/Drawing No(s).: N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Apphcablv Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date October 25 Y20IlL Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION [,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period 4o /2..- /c - -- / , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor hh' employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the I ector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro r connected with this inspection. JF Swan ,Commissions NBI1473-NC1524, N-I

                     -Inspector'sSignature                                                        National Board. State. Province, and Endorsements Dat*a           ]-*                             ,       2.*,

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi

1. Owner fluke Fnerov Carohin~q. 11 LC Date 9/22/2011 Duke Enerov Carolinas L 526 South Church Street. Charlotte, NC, 28201 Sheet I of 2 A AA-.,
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1956861-56 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energry Carolinas, LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street Charlotte. NC 28201-1006 Address Expiration Date: N/A

4. Identification of System CF - Feedwater
5. (a) Applicable Construction Code ASME 111 19271 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected. ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-CF-173 Duke Energy 00161 N/A N/A N/A Removed No IMCA-CF-173 Duke Energy 38103 N/A N/A :N/A Installed No

7. Description of Work Replaced ComsbonentgPart/AMurtenance Additional Description Replaced snubber on hanger IMCA-CF- 173
8. Tests Conducted: Hydrostatic F Pneumatic r- Nominal Operation Pressure IT Exempt F' Other F" Pressure PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 18 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1591-01.0i Support/Restraint Sketch/Drawing No(s).: IMCA-CF-173 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist . Date September 22 ,20I__ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

    !-    //    - //.            to                  -               and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. JF Swan -- Commissions NBI1473-NCI524, N-I

        -    /I      Inspector's Signature"                                                        National Board, State, Province, and Endorsements

_/ I

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas. LI. LC Date 10/6/2011 Duke Energv Carolinas L 526 South Church Street Charlotte, NC, 28201 Sheet 1 of 2 Address
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hap-ers Ferry Road, l-untersville, NC 28078 1957052-02 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Type Code Symbol Stamp:

Name Authorization No.: 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date:

4. Identification of System NC - Reactor Coolant
5. (a) Applicable Construction Code ASME III 19271 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed ition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Cornmonents Corrected, ASME Code Name of Manufacturer National Other Year Removed. or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

SG D Lisega Snubber Duke Energy 7 N/A N/A N/A' Installed No

7. Description of Work Replaced Component/Part/Appurtenance Additional Description Replaced control valve in Lisega Snubber (SG-D)
8. Tests Conducted: Hydrostatic F Pneumatic r- Nominal Operation Pressure F Exempt W Other r" Pressure PSI Test Temp. _ F Description (Optional): Support for Steam Generator "D"

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIViTY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: N/A in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing NOSsW.: N/A Flow Diagram No(s).: N/A Support/Restraint Sketch/Drawing No(s).: SG-D (07) other Applicable Information (e.g., W.O. No.. EC No.) if not included elsewhere on N IS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date October 6 .20 I! Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period 9 . ZS - // to ID - 9L.-& , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Ins ector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from ed with this inspection. JF Swan _ I Commissions NBI 1473-NC 1524, N-I

         *)/         Inspector's Signature 7                                              National Board. State, Province, and Endorsements Date    Dt                                            I 2o/__/

2-/7

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke EnerM Carolinas. LILC - Date 12/1/2011 LI Duke Energy Carolinas, 526 South Church Street Charlotte, NCt 28201 of 2 Address Sheet 1
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1957 177-08 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A
                           .26.S...h..h..ch.S.ree. Charl...e. NC 282.        00 Address                                                                         Expiration Date:        N/A
4. Identification of System NC - Reactor Coolant
5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

INCI Crosby N56925-00-0003 27 N/A 1974 Installed Yes INCI Crosby N56925-00-0004 28 N/A 1974 Removed Yes

7. Description of Work Replaced Component/Part/Appurtenance Additional Description Replaced valve INC I
8. Tests Conducted: Hydrostatic " Pneumatic - Nominal Operation Pressure FR E.xempt - Other r Pressure PSI Test Temp. OF Description (Optional): Pressure test was performed in coniunction with the Class A walkdown

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X!

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 6 in. (nominal) System Class: ASME Class I Weld Isometric Drawing No(s).: MCFI-INC5 Flow Diagram No(s).: MCF ~D- 155'3-02.00 Support/Restraint Sketch/Drawing No(s).: N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist f,*' %4.

                                                                                               ---                                                      Date December I      ,20 11 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina                                                               and employed by Hartford Steam Boiler Inspection and Insurance Company                            of
.Connecticut                                                                  have inspected the components described in this Owner's Report during the period I-      -a - /  Z            to                       4ZC.:
                                                -. -Z-/i., and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective mesures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the spector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro or connected with this inspection. IF Swan f

                                          ý        ,Commissions                                                       NBI 1473-NC 1524, N-I Inspector's SignaturF S                       ,-National                                                   Board, State, Province, and Endorsements D(1;                                                      0ý

4R r f

                                                ,.         C. FO S         Y     VAALV E          Ca    OAQ .            CO c Ikj, S,       L.    .2.,    /.:,    5'_                              WR ENTHAM , MASS FORM N- FOi SAFETY A; SAFETY RELIEF VALVES As required by the Provisions of the ASME Code P.ules Q.                  .1I XB-27 DATA REPORT Safety and Safety Relief ValVes                                                               I Vm,rn,,ctired    Y Crosby Valve & Gatce Company,                         43 KendrLck St.,           Wrentham,          'ass. 02093 I

616 HB-BP-86 Name and Address I' lcel . N-56925

2. Mar.ufictured For Duke Charott.e, Power Company Oider No.

North C_9_olina Name and Address N-300560 Contract Date Order N".. 2/12/73 A-33957

  -. owner       Duke Power Ccr-pany, 422 South Church St..                                Charlotte,        North Carolina 28201 Name and Address
4. Location of Plant McGuire Nuclear Stati.on Unit #I, Cowans Ford. North Carolina
5. Valve Identification 1-NC-3 serial No. N56925-00-0003 Drawing No. DS-C-56925 Rev. 0 2.154 Type Safety orifice Size M Pipe Size Inlet 6. Outlet 6 Safety.S:ifety Rehef.pilot.Pow*r Actuated Inch Inch Inch in, 1,
6. Set Pressure (PSIG) 24R5# 700 F Rated Teimper.,ure Stamped Capacity 420006#/hr. 3 r. Overp~ressure- 3 Ijlnwdc~.nui IsiG, 124 Ilydrostatic Test (PSIG) Inlet 4 575 Complete Valve " JV
7. The material. design. construction and workmanship comply with ASME Code. Sectin; Ill.

Class

  • I Edition 1971 Addenda Date Winter 1972 pressure Containin; o, Pressure Retaining Components Serial No. Material Speclihatlon
a. Castings Identification lncluding Type or Gr.,de ASTM A-351-72 Gr. CF8M Body N90397-31-0001. ASME SA-351 Gr. CFS:. __

AST7.I A-105-71 Gr. II Bonnet N~90353-34-0014 ASME SA-1.05 Or. II

b. Bar Stock and Foigings Support Rods Nozzle -A.G~ HEF Disc Insert To H9015~0-32-0029 ASTMA-.S:105.7 Gr. 11______

Sprinr Washers Bottom AS'XN A-19J-YO Nr B6 Adjusting Bolt N'90-151 0042 ASKL S-1.93 Cr. B6 __ Spindle N90354-34-0019 ASITM A-276-72 T)ypc 440 Spindle Ball N903,55-0019 ASIM SA-276 TNvpt. 440 C I -

                                                                                                                                                  /

C r P Serial No. or Material Spectric~cl 00 e, Identification Including Type or Grade I. N-X-2761-0015 I mlAS'lhW A-304' Cr. 57Jfei

       .. O~ber Parts such as Pilot Components Di.c v!older                                 N90356-35-0016                        Inconel 718 t7.

ASTM A-I93-7i U.. B/ lon-et Stud 87589 AS%.%: ASTM[ SA-193A:9-il 37 (:r. G5. Bonnet Stud Nut 2371 2 AWE SA- 19. 4 .r

                                                                                             ...        Z .
                                                                                                     ..SA       94 C We certify that the statements made in ibis report are correct.

DLto -... V 19 SSigned .Crosby Valve & C o. "_ .... _ _ _ _ . Manufacturer QA 21fa ager Certificate of Authorization No. 331. expires __Jgvember, 9: 1974-. DESIGN ITOPM.IATION ON FILE AT CROSBY VALVE & GAGE COTA',ANY. DESIGN RUPORT NO. EC-158. CERrIFICATE OF SHOP INSPECTIOU. I. the undersigned. holdirng a. alid commission issued by the National Board of Boiler a3rd. Pressiute Vessel Inspcc'.ors arý_ the State or Province of . and employed by Mutual Boiler & :lachirlerv Insurancc Co..'.. tha,,,. I. have] e inspected the'equipmentL descr&bed in this Da.- Report on - and statechat to the best of my knot.'ledge and belief..the himnuticturerI hIas constructed hliti equip, ment in accordance with the apZýicable Subsections of A,\S. Section IlI. By signiog this cPitificate. iteither the Inspector nor hIs enqployer :naks any wa'.ran:V. e-pressed or implied. concerning :-e equtipment described in this Data Report.Furthec..nore. neth;tt the Inspe"ccot nor his employer .%,ail be liable in any mainer for any .personal injury or, pruperty damage or a loss of any kind 2r---sing frcin or connected with this inspection.

                                                           *Factory Mutual Group of Insurance Co.

1 . Date - $:19-

                                              .- - -         Cmissions               AI/Co          7..""
                             "(I{spector)                        "         ,,;atio   lllar
                                                                                        ,*.,.nal l   -. Provi-nce .r1 .,

FORM NIS-2 OWNER'S REPORT FOR REPATI/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Pner~v Carnlinaq LI 1C Date 10/7/2011 Duke Enerow Carolin L 526 South Church Street. (Charlotte, NC, 28201 526~

Sot hrhSre

                                  ,                                                                                                Sheet   I         of 2
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 02002923-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street_ Charlotte. NC 28201-1006 526 South Chu h Street- Ch lotte NC 28201-1006 Address Expiration Date: L-/"

4. Identification of System NV - Chemical And Volume Control
5. (a) Applicable Construction Code ASME IHl 1921. Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Corn onents Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

Valve I NV-810 Kerotest E9-16 7529 N/A 1975 Corrected Yes A. A. -.1. L 1. A.

7. Description of Work Oth er (Describe Below)

Additional Description Se al welded body to bonnet on valve INV-810

8. Tests Conducted: Hydrostatic r Pneumatic F Nominal Operation Pressure F Exempt F7 Other F Pressure *PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 2 in. (nominal) System Class: ASME Class I Weld Isometric Drawing No(s).: MCFI-INV-25 Flow Diagram No(s).: MCFD-1554-01-00 Support/Restraint Sketch/Drawing No(s).: N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCM-1205.01-0032-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed F. R. Sorrow, QA Tech. Support Date 10-7 ,20 1l Owner or Owner's s'signee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

        -  *        - /(/ to /0              7L , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from r connected with this inspection. JF Swan r; =y--_..ej,-Commissions N1l1473-NC1524,N-I INational Board, State, Province. and Endorsements Date /D - 7 , 20_&

FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

1. Owner Duke Energv Carolinas L LC Date 10/10/2011 526 South Church Street, Charlotte, NC, 28201 Sheet I of 2 Address
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 2002923-06 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Type Code Symbol Stamp:

Name Authorization No.: 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date:

4. Identification of System NV - Chemical And Volume Control
5. (a) Applicable Construction Code ASME III 192L Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Com onents_

Corrected, ASME Code Nampeof Manufacturer National Other Year Removed, or Stamped Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) I MCR-NV-848 Duke Energy N/A N/A N/A N/A Installed No

7. Description of Work ReL* ,ia..,u '..UIhILPVLLtIA tJ al Uniij. U.- IaQL-L Additional Description Retplaced item 2 (1 x I x 1/4 angle) on hanger IMCR-NV-848.
8. Tests Conducted: Hydrostatic - Pneumatic r- Nominal Operation Pressure " Exempt F Other r Pressure PSI Test Temp. __.°F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2_____

Component Line Size: 4 in. (nominal) System Class: ASME Class I Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1554-01.00 Support/Restraint Sketch/Drawing No(s).: I MCR-NV-848 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist ,.Date October 10 _ 20 I1 Owner or Owner's Designee. Title CERTiFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

 .North Carolina                                                                  and employed by Hartford Steam Boiler Inspection and Insurance Company                             of Connecticut                                                                     have inspected the components described in this Owner's Report during the period I

7- - // to " and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither th spector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection JF Swan Commissions NB11473-.NC1524, N-I

                      -Inspector's Signature t                                                       National Board, State, Province, and Endorsements Daote/             /0 -0

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Enerv Carolinas, LI LC Date 10/12/2011 526 ~nisth Chi~rch street Charlotte NC. 28201 1 of 2 Sheet Address
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road. Huntersville, NC 28078 2004055-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Enerv Carolinas, LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME [II 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed ition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Com onents Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

NV Piping Duke Energy N/A 37 N/A 1981 Installed Yes

7. Description of Work Weld Repar Additional Description Base metal repair at hanger IMCR-NV- 10591.
8. Tests Conducted: Hydrostatic " Pneumatic r" Nominal Operation Pressure F Exempt r- Other r- Pressure .PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 2 in. (nominal) System Class: ASME Class I Weld Isometric Drawing No(s).: MCFI-INV45 Flow Diagram No(s).: MCFD- 1554-01.02 Support/Restraint Sketch/Drawing No(s).: iMCR-NV-1059 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NV-04 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist . Date October I , 20 1 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

 .to                                Z -0 /and                      state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owne's Report. Furthermore, neither the In ector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro r connected with this inspection. ' JF Swan )'.At -10 6-f"7. i* /.

                                           /'nmmiscinn.            .     ----                                     NBI1473-NC1524, N-I Inspector's Signature                                                    National Board. State. Province. and Endorsements Date             (5& -/                                201/

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XT

1. Owner fliike~ Pne~rov Carolinas. LI LC Date 10/15/2011 Duke Enerow Carolinas Ll 526 South Church Street Charlotte, NC. 28201 Sheet I of 2 A AA- ,.

McGuire Nuclear Station

2. Plant Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 2004926-21 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas. LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date:

4. Identification of System WL - Liquid Waste Recycle System
5. (a) Applicable Construction Code ASME III 1927 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

WL Piping Duke Energy N/A 29 N/A 1981 Installed Yes

7. Description of Work Replaced Component/Part/Aw purtenance Additional Description Replaced piping and welds per EC 106925
8. Tests Conducted: Hydrostatic F Pneumatic F Nominal Operation Pressure S1 Exempt F Other F Pressure 15 PSI Test Temp. 78 6F Description (Optional): test performed per procedure MP/0/A/7650/076.

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 6 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: MCF1-W8 Flow Diagram No(s).: MCF D-1 565-07.00 Support/Restraint Sketch/Drawing No(s).: N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: EC106925 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist \(_7<* ,,,,,,,, Date October 15 20IL Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

        -      -                             - ,                   , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o onnected with this inspection JF Swan /

                                            ;"f                                                     Commissions NBl 1473-NC1524, N-d fInspector's Signature  ý   tr                                                 National Board, State. Province, and Endorsements Date                   02-L

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas. LL C Date 10/14/2011 Duke Energ-v Carolinas LL 526 South Church Streer Charlotte, NC. 28201 Sheet I of 2 Address
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferr' Road, Huntersville, NC 28078 2005281-15 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Type Code Symbol Stamp: N/A Name Authorization No.: N/A 526 South Church Street Charlotte NC 28201-1006 Address Expiration Date: N/A
4. Identification of System WL - Liquid Waste Recycle System
5. (a) Applicable Construction Code ASME III 191L Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section X1 used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Com onents_

Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) IMCR-WL-785 Duke Energy N/A N/A N/A N/A Installed No

7. Description of Work Replaced Component/Part/Apourtenance Additional Description H inger IMCR-WL-785 worked per EC 106925.
8. Tests Conducted: Hydrostatic - Pneumatic r- Nominal Operation Pressure -- Exempt F Other F' Pressure .PSI Test Temp. _

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 6 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: MCRFI-IWL84 Flow Diagram No(s).: N/A Support/Restraint Sketch/Drawing No(s).: 1MCR-WL-785 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: EC106925 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist - Date October 14 _ 20 .H Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

  /&5 /C         -//             to IC       "7-//                ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner'% Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspectio

.JF Swan                       *
  • Commissions NBI 1473-NC 1524, N-I Inspector's Signature *National Board. State. Province, and Endorsements le Date -1'7 2 Wno- ,,, I

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Enermv Carolinas, LL LC Date 10/15/2011 Charlotte. NC, 28201 Sheet 1 of 2 526 South Church Street AA
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road. Huntersville, NC 28078 2005296-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Ener.y Carolinas, LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A

4. Identification of System NC - Reactor Coolant
5. (a) Applicable Construction Code ASME 11 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section Xl Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCR-NC-769 Duke Energy 16601 N/A N/A N/A Removed No I MCR-NC-769 Duke Energy 38529 N/A N/A N/A Installed No
7. Description of Work Re, vlaced Comnionient/Part/Appurteniance Additional Description R4eplaced snubber on hanger IMCR-NC-769
8. Tests Conducted: Hydrostatic " Pneumatic F" Nominal Operation Pressure r Exempt F Other F Pressure PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 4 in. (nominal) System Class: ASME Class I Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: N/A Support/Restraint Sketch/Drawing No(s).: IMCR-NC-769 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicahie Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist , Date October 15 ,20 L Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

     /n-          - -!                  9               - Y and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Insp ctor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection.

 .F Swan                                                                                    Commissions NB!1473-NC1524, N-I uNational                                                          Board, State. Province, and Endorsements

6.0 Pressure Testing There is (1) Class 1 (Category B-P) pressure test zone that requires pressure testing each refueling outage. Table 6-1 shows a completion status of the Class 1 (Category B-P) pressure test zone conducted during refueling cycle EOC 21. Table 6-1 Class 1 Pressure Test Comoletion Listina EOC 21 EOC 21 VT-2 Zone Completion Examination Code Case(s) Number Boundary Dwg(s) Status Date Used 1NC-070L-A MC-ISIL-1553-01.00 Complete 10/14/2011 N-566-2 MC-ISIL-1553-02.00 MC-ISIL-1553-02.01 MC-ISIL-1554-01.00 MC-ISIL-1554-01.01 MC-ISIL-1554-01.02 MC-ISIL-1561-01.00 MC-ISIL-1562-01.00 MC-ISIL-1562-02.00 MC-ISIL-1562-02.01 MC-ISIL-1562-03.00 MC-ISIL-1562-03.01 There are two zones for the (67) Risk Informed Segments (Category R-A) that are required to receive a pressure test each refueling outage. Zone 1NC-070L-A contains the Class 1 Risk Informed Segments and Zone IRI-001L-B contains the Class 2 Risk Informed Segments. Table 6-2 shows a completion status of the (66 out of 67) Risk Informed Segments pressure tested during refueling cycle EOC 21. Segment NV-109 was not pressure tested during EOC21 due to the pump being out of service (reference PIP M-1 1-08692). The pump will be pressure tested during the 1st quarter of 2012 and the results reported in the EOC22 Summary Report. Table 6-2 Risk Informed PressureTest Completion Listing EOC 21 Code Zone Segment Completion EOC 21 Case(s) Number Boundary Dwg(s) Number Status VT-2 Date Used 1 1NC-070L-A MC-ISIL-1553-01.00 NC-18 Complete 10/14/2011 N-566-2 2 MC-ISIL-1553-02.00 NC-19 3 MC-ISIL-1554-01.00 NC-20 4 MC-ISIL-1554-01.01 NC-21 5 MC-ISIL-1562-01.00 NC-23 6 NC-86 7 NC-89 8 NC-90 9 NC-054 10 NC-055 11 NC-056 12 NV-033A 13 NV-033B Outage 7/EOC 21 Page 1 of 6 McGuire Unit 1 Revision 0 Section 6 - Third Ten-Year Interval January 5, 2012

Table 6-2 Risk Informed PressureTest Completion Listing EOC 21 Code Zone Segment Completion EOC 21 Case(s) Number Boundary Dwg(s) Number Status VT-2 Date Used 14 NV-034A 15 NV-034B 16 NV-037 17 NV-038 18 NV-041A 19 NV-041 B 20 NV-042A 21 NV-042B 22 NV-030A 23 NV-030B 24 NV-032A 25 NV-032B 26 NV-035 27 NV-036 28 NV-039A 29 NV-039B 30 NV-040A 31 NV-040B 32 NI-068 33 NI-069 34 NI-070 35 4 4 NI-071 4 9 .0. 36 1RI-001 L-B MC-ISIL-1554-01.00 NV-020H Complete 10/14/2011 None 37 MC-ISIL-1554-01.01 NV-020F (except 38 MC-ISIL-1554-01.02 NV-020GA Segment 39 MC-ISIL-1554-01.03 NV-020AD NVI 09) 40 MC-ISIL-1554-03.00 NV-020B 41 MC-ISIL-1554-03.01 NV-020CA 42 MC-ISIL-1562-01.00 NV-020D 43 MC-ISIL-1562-03.00 NV-020EA 44 NV-01 9AA 45 NV-019B 46 NV-019D 47 NV-020AB 48 NV-020AC 49 NV-021A 50 NV-021 B 51 NV-002AB 52 NV-002D 53 NV-019C 54 NV-019E 55 NV-028 56 NV-029 57 NV-026 Outage 7/EOC 21 Page 2 of 6 McGuire Unit I Revision 0 Section 6 - Third Ten-Year Interval January 5, 2012

Table 6-2 Risk Informed PressureTest Completion Listing EOC 21 Code Zone Segment Completion EOC 21 Case(s) Number Boundary Dwg(s) Number Status VT-2 Date Used 58 NV-027 59 NV-080A 60 NV-080B 61 NV-084A 62 NV-084B 63 NV-084C 64 NV-002C 65 NV-1 08A 66 NV-109 Incomplete 67 NV-011A There are (30) Class 2 (Category C-H) pressure test zones that require pressure testing once each Inspection Period. Table 6-3 shows a completion status of the (30) Class 2 (Category C-H) pressure tests zones that require pressure testing for the Third Period of the Third Ten-Year Interval. The Third Period began on 12/01/08 and will extend to 04/01/2012. The completion status for Zone 1NV-045L-B will be documented in the EOC22 Summary Report. Table 6-3 Class 2 - 3rdPeriod Completion Listing VT-2 Zone Examination Code Cases Number Boundary Dwg Completion Status Date Used 1 1BB-096L-B MC-ISIL-1580-01.00 Complete 11/10/2011 None 2 1BB-098L-B MC-ISIL-1572-03.00 Complete 10/14/2011 None MC-ISIL-1580-01.00 MC-ISIL-1584-01.00 3 1CA-006L-B MC-ISIL-1592-01.00 Complete 10/14/2011 None 4 ICA-032L-B MC-ISIL-1584-01.00 Complete 11/10/2011 None MC-ISIL-1591-01.01 MC-ISIL-1592-01.00 MC-ISIL-1617-01.00 5 1FW-027L-B MC-ISIL-1554-03.00 Complete 08/24/2011 None MC-ISIL-1554-03.01 MC-ISIL-1561-01.00 MC-ISIL-1562-03.00 MC-ISIL-1563-01.00 MC-ISIL-1571-01.00 Outage 7/EOC 21 Page 3 of 6 McGuire Unit 1 Revision 0 Section 6 - Third Ten-Year Interval January 5, 2012

Table 6-3 Class 2 - 3rd PeriodCompletion Listing VT-2 Zone Examination Code Cases Number Boundary Dwg Completion Status Date Used 6 1ND-019L-B MC-ISIL-1554-01.02 Complete 11/11/2011 N-533-1 N-566-2 MC-ISIL-1561-01.00 MC-ISIL-1562-03.00 MC-ISIL-1562-03.01 MC-ISIL-1563-01.00 MC-ISIL-1571-01.00 MC-ISIL-1572-01.00 7 1ND-050L-B MC-ISIL-1561-01.00 Complete 08/31/2011 N-566-2 MC-ISIL-1562-03.01 MC-ISIL-1563-01.00 8 1NI-021L-B MC-ISIL-1562-02.00 Complete 4/14/2010 None MC-ISIL-1562-02.01 MC-ISIL-1572-01.01 9 1NI-022L-B MC-ISIL-1562-03.00 Complete 11/21/2011 None MC-ISIL-1562-03.01 10 1NI-039L-B MC-ISIL-1562-03.01 Complete 3/19/2010 None 11 INI-053L-B MC-ISIL-1562-03.00 Complete 11/21/2011 None 12 1NI-060L-B MC-ISIL-1562-02.01 Complete 4/10/2010 None MC-ISIL-1562-03.00 13 1NI-071L-B MC-ISIL-1562-01.00 Complete 09/23/2011 N-566-2 14 1NI-074L-B MC-ISIL-1562-03.00 Complete 11/21/2011 None 15 1NM-046L-B MC-ISIL-1572-01.01 Complete 10/13/2011 None 16 1NS-023L-B MC-ISIL-1563-01.00 Complete 08/18/2011 None 17 1NS-024L-B MC-ISIL-1563-01.00 Complete 11/21/2011 None Outage 7/EOC 21 Page 4 of 6 McGuire Unit 1 Revision 0 Section 6 - Third Ten-Year Interval January 5, 2012

Table 6.3 Class2 - 3rd PeriodCompletion Listing VT-2 Zone Examination Code Cases Number Boundary Dwg Completion Status Date Used 18 INV-016L-B MC-ISIL-1554-01.00 Complete 10/07/2011 None MC-ISIL-1554-01.01 MC-ISIL-1554-01.02 MC-ISIL-1554-02.00 MC-ISIL-1554-02.01 MC-ISIL-1554-03.00 MC-ISIL-1554-03.01 MC-ISIL-1554-05.00 MC-ISIL-1561-01.00 MC-ISIL-1562-01.00 MC-ISIL-1562-03.00 19 INV-017L-B MC-ISIL-1554-01.00 Complete 11/10/2011 None MC-ISIL-1554-01.01 MC-ISIL-1554-01.02 MC-ISIL-1554-01.03 20 1NV-018L-B MC-ISIL-1554-01.02 Complete 11/10/2011 None 21 INV-020L-B MC-ISIL-1554-01.02 Complete 4/13/2010 None 22 1NV-045L-B MC-ISIL-1554-03.00 Incomplete N/A None 23 1NV-051L-B MC-ISIL-1554-03.01 Complete 08/26/2011 None 24 iRN-004L-B MC-ISIL-1574-04.00 Complete 1011212011 None 25 1RV-002L-B MC-ISIL-1604-03.00 Complete 10/06/2011 None 26 1SA-035L-B MC-ISIL-1593-01.02 Complete 08/17/2011 None 27 ISM-006L-B MC-ISIL-1572-03.00 Complete 11/10/2011 None MC-ISIL-1591-01.01 MC-ISIL-1593-01.00 MC-ISIL-1593-01.03 Outage 7/EOC 21 Page 5 of 6 McGuire Unit I Revision 0 Section 6 - Third Ten-Year Interval January 5, 2012

Table 6-3 Class 2- 3rd PeriodCompletion Listing VT-2 Zone Examination Code Cases Number Boundary Dwg Completion Status Date Used 28 1SM-036L-B MC-ISIL-1593-01.00 Complete 11110/2011 None MC-ISIL-1593-01.02 MC-ISIL-1593-01.03 29 ISM-037L-B MC-ISIL-1593-01.00 Complete 11/10/2011 None MC-ISIL-1593-01.03 30 IYA-043L-B MC-ISIL-1617-01.00 Complete 11/16/2011 None Section 6 Prepared By: Date: Section 6 Reviewew By: Date: Section 6 Approved By: Date: Outage 7/EOC 21 Page 6 of 6 McGuire Unit i Revision 0 Section 6 - Third Ten-Year Interval January 5, 2012

7.0 Containment Inservice Inspection (IWE) Inservice inspections of Class MC components are performed in accordance with the ASME Boiler and Pressure Vessel Code, Section XI, Subsection IWE, 1998 Edition with the 2000 Addenda. Article IWA-6000, Records And Reports, paragraph IWA-6210, requires the Owner to prepare inservice inspection summary reports for inservice inspections performed on Class 1 and 2 pressure retaining components and their supports. IWA-6000 does not address inservice inspection summary reports for Class MC pressure retaining components and their supports, and the Code does not require preparation and submittal of summary reports for Class MC components. As such, Section 7.0 of this Summary Report does not contain information specified in IWA-6220 or IWA-6230. Section 7.0 of this report contains only that information applicable to Code Class MC components, as required by 10 CFR 50.55a(b)(2)(ix)(A), which states:

       "The applicant or licensee shall evaluate the acceptability of inaccessible areas when conditions exist in accessible areas that could indicate the presence of or result in degradation to such inaccessible areas. For each inaccessible area identified for evaluation, the applicant or licensee shall provide the following in the ISI Summary Report as required by IWA-6000:

(i) A description of the type and estimated extent of degradation, and the conditions that led to the degradation; (ii) An evaluation of each area, and the result of the evaluation, and; (iii) A description of necessary corrective actions. General Visual Examinations were performed on accessible surfaces of the Steel Containment Vessel during refueling outage 1EOC21 in accordance with the ASME Code, Section XI, IWE-2500, Table IWE-2500-1, Examination Category E-A, Item El.11. During this inspection, conditions were observed that were deemed to be reportable per 10 CFR 50.55a(b)(2)(ix)(A). The observed conditions and the information required by 10 CFR 50.55a(b)(2)(ix)(A) are provided below. Description of the Type of Degradation: Location of Indication Pipe Chase floor and containment vessel insulation panel/floor interface below the Unit 1 Fuel Transfer Tube near azimuth 2400 - 2700, Elev. 725. Description of Indication: Standing water, boric acid deposits and staining were observed on the Pipe Chase Floor and the base of the stainless steel insulation panel covering the bottom portion of the Steel Containment Vessel interior surface. Although there was no direct indication of containment vessel degradation in this area, degradation of the Steel Containment Vessel shell plate behind the insulation panel could not be readily confirmed by the General Visual Examination. Because the Steel Containment Vessel is not accessible for visual examination at this location, the condition of the Steel Containment Vessel shell behind the insulation panel and concrete could not be readily determined. Outage 7/EOC 21 Page 1 of 3 McGuire Unit 1 Revision 0 Section 7 -Containment Inservice Inspection (IWE) Information January 12, 2012

Problem Investigation Process Report PIP #M-1 1-06962 was written, in part, to address this problem. Estimated Extent of Degradation and Conditions That Led to the Degradation: Based on inspections and evaluations documented below, Duke Energy does not believe that the conditions identified in this report have resulted in actual degradation of the Steel Containment Vessel shell plate behind the insulation and concrete floor interface at this location. The source of borated water has not been determined. However, the observed conditions are likely the result of one or more of the following:

1. Melting Ice from the Ice Condenser.

Melting ice from the Ice Condenser is a possible source of the borated water due to unexpected elevated ice condenser temperatures that occurred on 9/20/11 (Reference PIP #M-1 1-6842). It should be noted that the moisture barrier directly above the fuel transfer tube did not show evidence of conditions that would allow moisture to access the Steel Containment Vessel shell plate, but melting ice water could have drained onto the Pipe Chase Floor.

2. Rain Water in the Equipment Hatch.

It is possible for rain water to enter through the Equipment Hatch, into the VX Fan Pit, and into lower containment through the divider barrier drains. When the Equipment Hatch is opened, water drains into lower ice condenser area (Reference PIP #M-1 1-6980). Rainwater drainage would follow a similar flow path as ice condenser leakage, but would not contain boric acid.

3. Decontamination "washdown" activities.

Water may have accessed this area during decontamination activities, but would not contain boric acid. Evaluation of the Affected Area and Results of the Evaluation: To confirm that the observed conditions had not resulted in degradation to inaccessible surfaces of the Steel Containment Vessel, the following actions were taken and completed during refueling outage 1EOC21:

1. Portions of the stainless steel insulation panel (and foamglass insulation) and Pipe Chase floor concrete (along approximately 6 inches at the base of the Steel Containment Vessel to a depth of approximately 1") were removed, and a direct visual examination (VT-1) of the interior surfaces of the Steel Containment Vessel were performed in this area. Ultrasonic thickness readings were also taken at this location to confirm the actual thickness of the shell plate. The VT-1 examination revealed some coatings degradation and minor surface rusting, but the condition of the shell plate was considered to be acceptable. No corrosion was observed beneath the interior concrete floor embedment zone interface. UT exams detected thicknesses consistent with the 1" nominal shell plate thickness (1.008", 1.009", and 1.014").
2. Ultrasonic thickness measurements were also performed from the exterior side of the Steel Containment Vessel at ten locations (near the floor elevation) to determine whether general corrosion was occurring at other locations behind the insulation Outage 7/EOC 21 Page 2 of 3 McGuire Unit 1 Revision 0 Section 7 -Containment Inservice Inspection (IWE) Information January 12, 2012

panel where the panel had not been removed on the interior of the Steel Containment Vessel in the Fuel Transfer Tube area. These UT thickness readings ranged from 1.007" to 1.014" and are consistent with the 1" nominal shell plate thickness. Because the VT-1 examinations and UT measurements indicated no significant metal loss on the Steel Containment Vessel shell plate, the condition of the Containment Vessel is considered acceptable at this time. Description of Necessary Corrective Actions

1. The foamglass insulation was replaced and the stainless steel panel was reinstalled in accordance with design drawings during refueling outage 1EOC21.
2. Moisture barrier material (sealant) was reinstalled along the base of the insulation panel to protect against any future moisture intrusion.
3. The McGuire Containment ISI Plan shall be revised to add examination of the affected area in accordance with the ASME Code, Section XI, IWE-2500, Examination Category E-C, Item E4. 11 (from the interior surface) and Item E4.12 (from the exterior surface) during the next inspection period, as required by IWE-2420.
4. McGuire Engineering shall evaluate the feasibility of implementing one or more of the following actions during refueling outage I EOC22:
a. Remove the bottom 6" of the insulation panel and foamglass insulation (as necessary) to clean and recoat surfaces of the Steel Containment Vessel shell plate at the Pipe Chase concrete floor embedment zone interface beneath the Fuel Transfer Tube. Restore foamglass insulation and stainless steel insulation panel, and replace/restore moisture barrier (sealant) at the base of the insulation panel at the Pipe Chase floor.
b. Remove the entire insulation panel and portions of the foamglass insulation (as necessary) beneath the Fuel Transfer Tube, clean and recoat surfaces of the Steel Containment Vessel shell plate at the Pipe Chase concrete floor embedment zone interface. Install new moisture barrier (sealant) at the containment vessel shell embedment zone interface, then restore foamglass insulation and stainless steel insulation panel, and replace/restore moisture barrier (sealant) at the base of the insulation panel at the Pipe Chase floor.
c. Install multiple inspection ports at the base of the insulation panel at the Pipe Chase floor to enable visual examination of the containment vessel shell/embedment zone interface at various locations around the periphery of the Pipe Chase and revise the Containment ISI Plan to include examination of these locations.

Outage 7/EOC 21 Page 3 of 3 McGuire Unit 1 Revision 0 Section 7 -Containment Inservice Inspection (IWE) Information January 12, 2012

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVTY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 16 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: :N/A Flow Diagram No(s).: MCFD-1591-01.Ol Support/Restraint Sketch/Drawing No(s).: IMCR-CF-403 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date October 1 ,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

qorth Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of
Connecticut have inspected the components described in this Owner's Report during the period
    -                            to        :      Z                 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspectio JF Swan / - ;_ Commissions .NBI 1473-NC 1524, N-I Insp~ctor's Signature--,/'7" .National Board, State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of: 2 Component Line Size: 1.5 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1554-02.00 Support/Restraint Sketch/Drawing No(s).: 1MC-I 683-NV.0 I-Ri 6 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: N/A Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X[.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date September 6  :, 2011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

Hartford Steam Boiler Inspection and Insurance Company of
 'North Carolina                                                           and employed by                                                                                    o Connecticut . .       ..          . ..     . . ...
 ..Connecticut_                                                            have inspected the components described in this Owner's Report during the period
                 -           t                                , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the In ctor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection.

                                                                                       ,Commissions
                                                                                         --                       NBI 1473-NC 1524, N-I Inspcto's SgnaureNational                                         Board, State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas_.LLC ........... .. Date 5/19/2011 526 South Church Street, Charlotte,. 2&2_01 .. Sheet 1 of22 Address
2. Plant McGuire Nuclear Station Unit I Name 12700 HBagers Fey* Road, HNutesvil!_NC 28078 1794910-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas LLC_ Type Code Symbol Stamp:

Name Authorization No.: 526 South Church Street,.Charlotte, NC 28201-1006 Address Expiration Date:

4. Identification of System SM - Main Steam
5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity .1998. Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-SM-104 Duke Energy 15835 N/A N/A N/A Removed No IMCA-SM-104 Duke Energy 38104 N/A N/A N/A Installed No 4 4- 4 4 4 4 9. .. .......... 4. 1 .. 4

7. Description of Work ReplacedCQomponent /Part/Appureinance Additional Description Replaced snubber onihanger IMCA-SM-104.
8. Tests Conducted: Hydrostatic F Pneumatic - Nominal Operation Pressure F Exempt F Other F' Pressure PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 42 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1593-01.03 Support/Restraint Sketch/Drawing No(s).: IMCA-SM- 104 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-SMA-003 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date May 19 ,20 1L Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

!:North Carolina                                                                and employed by Hartford Steam Boiler Inspection and Insurance Company of Conniecticut have inspected the components described in this Owner's Report during the period
   .5 -       - "-16/            to                     "ý
                                                        --         ,-and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector no his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither t ýý-nspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fron r connected with this inspectio IJF Swan " Commissions NB11473-NC1524, N-I National Board, State, Province, and Endorsements Inspector's Signat ",,/ " 20//

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X!

1. Owner Duke Energy Carolinas, L C Date .8/31/2010 526 South Church Street. CharlotteNC. 28201 -........... ...... . Sheet 1 of 2 Address
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 .1794913-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy CarolinaLLC..-.

Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street,_Charlotte, NC 28201-1006 Address Expiration Date: N/A

4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME HIl 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity _1_998-E-dition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-ND-286 Duke Energy 15869 N/A N/A N/A Removed No IMCA-ND-286 Duke Energy . 37218 N/A N/A N/A Installed No

7. Description of Work iv..pna1..u1k k,.AVlfl.JfVIirllLJA at urI
                                                                          "  I..JJ.U. tA~nan.I.tA,.*.

Additional Description rei laced snubber on hanger I MCA-ND-286.

8. Tests Conducted: Hydrostatic F Pneumatic FT Nominal Operation Pressure rT Exempt
  • Other r" Pressure ___PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet of Component Line Size: 8 (nominal)
                                                            -in.                        System Class:       ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).:                                     MCFD-1561-0 1.00 Support/Restraint Sketch/Drawing No(s).:                 IMCA-ND-286 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:                                 MCSRD-NDA-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date August 31 ,2010 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

.Connecticut                                                                    have inspected the components described in this Owner's Report during the period
                                 -to.         3                      and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Insp or nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection.

"JFSwan                                          -Commissions r-                                                             NC 1524, N-I Inspector's Signature                                                 "       National Board, State, Province, and Endorsements Date/        ,3' *      /"                            ,2.;

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As .Required by the Provisions of the ASME Code Section XI I. Owner Duke Energy Carolinas,_LLC ......-. Date 8/19/2010 526 South Church Street. Charlotte. NC. 28201 ______ ___

                                                                                                                       ._^_ 1 S11eL
                                                                                                                                        ^

01I___ Address

2. Plant McGuire Nuclear Station Unit _

Name 12700 Ha ers Ferry Road, Huntersville,, NC 28078 .1794915-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)

3. Work Performed by Duke Energy Carolinas, LLC Type Code Symbol Stamp: N/A Name Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A
4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and -Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) 'N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-ND-298 Duke Energy .22181 N/A N/A N/A Removed No

*IMCA-ND-298              Duke Energy              .      37597                       . N/A                      N/A                                  N/A       Installed                        No
7. Description of Work Replaced COMIponentlPart/A~ppurtenac Additional Description replaced snubber and bolting material on hanger IMCA-ND-298
8. Tests Conducted: Hydrostatic F Pneumatic r Nominal Operation Pressure F Exempt F Other F" Pressure _____PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 8 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1561-0 1.00 Support/Restraint Sketch/Drawing No(s).: IMCA-ND-298 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NDA-006 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist " Date August, 19 ,20 10 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

     -        -_to

_ _,_and 0149L_ state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's eport. Furthermore, neither the i spector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or onnected with this inspection. JF Swan - Commissions NC1524, N-I SInspector's Signature National Board, State, Province, and Endorsements Date  ? 26XL

FORM NIS-2 OWNER'S REPORT FOR REPAIRJREPLACEMENT ACTMTY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Pner~v Carnlina~ VTLC Date 9/2/2010 526 South Church Street Charlotte, NC, 28201 Sheet i of 2 Address
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 .1794916-01 Address Work Order 9 (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: :N/A Authorization No: N/A 526 South Church Street, Charlotte, NC 2820 1-1006 N/A Address Expiration Date:
4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME III 19 711 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition, with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed. or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-ND-290 Duke Energy T21526 N/A *:N/A N/A Removed No MCA-ND-290 'Duke Energy . 38071 N/A ýN/A :N/A Installed No

7. Description of Work )laced Component/Part/AppIurtenance Additional Description Re.placed snubber on hanger 1MCA-ND-290.
8. Tests Conducted: Hydrostatic FT Pneumatic r" Nominal Operation Pressure F Exempt f Other F Pressure, PSI Test Temp.

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 12 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: :MCFD- 1561-01.00 Support/Restraint Sketch/Drawing No(s).: IMCA-ND-290 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist ,." , Date September 2 -, 20 10 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

Connecticut have inspected the components described in this Owner's Report during the period 9 2 M . to 16*- and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither t Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from/f connected with this inspection JF Swan Commi sions NC1524, N-i

                          ;tor's Signature    .                                                    National Board, State, Province, and Endorsements g            Inspec Date                                                     20/aýD

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner DukeEnergy Carol inas,- ..-----... . .. ... .... . . . Date 8/31/2010 2

526 South Church Street, Charlotte N*C, 28201_. .... Sheet i Address

2. Plant McGuire Nuclear Station Unit .1 Name 127l00Hagqs HunteFrsville. NC 28078
1794917-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 . . 'M/A Address Expiration Date: ...
4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME III 19 71* Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-ND-287 Duke Energy 20507 N/A . N/A N/A Removed No 1MCA-ND-287 Duke Energy .37858 N/A .N/A. N/A Installe-d No

7. Description of Work Re )laced Component/Part/Appurtenance Additional Description re placed snubber on hanger IMCA-ND-287.
8. Tests Conducted: Hydrostatic F' Pneumatic r" Nominal Operation Pressure r" Exempt R Other F Pressure ____PSI Test Temp. _ IF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of . 2 Component Line Size: S in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1561-01.0 Support/Restraint Sketch/Drawing No(s).: IMCA-ND-287 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NDA-002 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Title Date August 31 ,20 10 Owner or Owner's Designee, CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

Connecticut have inspected the components described in this Owner's Report during the period I? [0 to* -and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither th Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection JF Swan Commissions NC1524, N-1 r S r National Board, State, Province, and Endorsements Date ________ _ 201

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI !. Owner __ Duk e g a n L-- - .-.- -..

                                                                             - .............-   -......     ...   .. Date 8/30/2010 526 South Church Street._Charotte,.N,       28201       ...............                              Sheet    I         of 2 Address
2. Plant McGuire Nuclear Station Unit I Name 12.7_0_._agerFerry..ad_, ntersv1e,NC M28078 1794919-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by DukeEnergyCar!n_ _LLNC. . .

Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte,. NC 28201-1 006 Address Expiration Date:

4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME Ill 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected. ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-ND-275 Duke Energy 21086 N/A N/A N/A Removed No IMCA-ND-275 Duke Energy .37859 N/A N/A N/A Installed No

7. Description of Work Re_ lated _Comonent/Part/Appurtenanc Additional Description re )laced snubber on hanger IMCA-ND-275.
8. Tests Conducted: Hydrostatic F" Pneumatic F Nominal Operation Pressure F' Exempt F Other r' Pressure .PSI Test Temp. _ °F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 8 in. (nominal) System Class: ASMEClass 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 156 1-0 1.00 Support/Restraint Sketch/Drawing No(s).: IMCA-ND-275 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NDA-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist '

  • Date August 30 ,201O_

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

*-" a             -Z0            to     3'--'*          -- 'Q, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the pector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro or connected with this inspection. I Sa* .Commissions NC 1524, N-I

                    /Inspector's Signature                                                      National Board, State, Province, and Endorsements Da6/               . "L/,20/**

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

1. Owner Duke Enrgy.Carolinas.i, L__LC_ ............... . ........... Date 8/30/2010

_.526_SouthChurch Street.. Charlotte. NC, 282_9_ ..-......... Sheet 1 of 2 Address

2. Plant McGuire Nuclear Station Unit I Name 12700 Hagrs Ferryo7d8 Huntersille,.XQ8078 :1794920-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Ene rgyCarolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street._h.airLotte, NC 28201-1006 N/A Address Expiration Date:
4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped -,

Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) IMCA-ND- 181 Duke Energy 20738 N/A N/A N/A Removed No IMCA-ND-181 Duke Energy 38060 N/A N/A N/A Installed No

7. Description of Work ReI 1aqed Co _mpon enUn/Paprt.Appu enance Additional Description re placed snubber on hanger IMCA-ND- 181.

.8. Tests Conducted: Hydrostatic F Pneumatic F Nominal Operation Pressure r" Exempt P Other F' Pressure. .PSI Test Temp. _ Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 3 in. (nominal) System Class: ASME*Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1561-01.00 Support/Restraint Sketch/Drawing No(s).: I MCA-ND- 181 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NDB-002 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist . Date August 30 - 20 0 Owner or Owner's Designee, Title I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

**'-- *L-.- ---/c9 to                     - .3 L      -.   !Dand state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owne's Report. Furthermore, neither the I pector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising froor connected with this inspection. JF SwanV2- o-ý i.. ..- Commisinno .NC1524, N-I Inspector's Signaturl S National Board, State, Province, and Endorsements Date 3- 204/a

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke E..EnerCgy.Carol inas,.LILC _.... .. ...- . . .. . .... .. D ate 9/2/2010 Charlotte. NC, 28201 .... Sheet I of 2 52.6. SouthChurch Skeeet,.

Address

2. Plant McGuirre-Nuclea. Station Unit I Name 1270Q HagureFerryRoad, Huntersville, NC 28078, 1794925-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Caro!inras, LLC Name Type Code Symbol Stamp:

Authorization No.: 526. South Church Street,* CharlotteNC 2820_1-1-006. Address Expiration Date:

4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME III 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity .1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-ND-270 Duke Energy 16565 N/A N/A N/A Removed No IMCA-ND-270 Duke Energy 38052 N/A N/A N/A Installed No

7. Description of Work Replaced Component/Part/Appurtenance Additional Description Replaced snubber and bolting material on hanger I MCA-ND-270.
8. Tests Conducted: Hydrostatic r Pneumatic F Nominal Operation Pressure r" Exempt F Other r- Pressure PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XT

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 8 in. (nominal) System Class: ASMEMClass 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1561-01 .00 Support/Restraint Sketch/Drawing No(s).: IMCA-ND-270 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist c - " - Date September 2 ,00__ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina A *. I- -,, Hartford Steam Boiler Inspection and Insurance Company r Connecticut have inspected the components described in this Owner's Report during the period to 9- 9 ( , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fron r connected with this inspe. JF Swan ' a, - Commisinno

                                                                                                ....... mm*sv*A*

NC 1524, N-I or's Signature / National Board, State, Province, and Endorsements (Inspect Date

FORM NIS-2 OWNER'S REPORT FOR REPAIR/EPLACEMENT ACTIVTY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Enerav Carolinas.ILILC Date 9/20/2011 526 South Church Street, Charlotte, NC, 28201 Sheet I of 2 Address
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hapers Ferry Road, Huntersville, NC 28078 1794935-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street, Charlotte. NC 28201-1006 Address Expiration Date:

4. Identification of System SM - Main Steam
5. (a) Applicable Construction Code ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed[ition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCA-SM- 182 Duke Energy 19913 N/A N/A N/A Removed No 1MCA-SM-182 Duke Energy 38112 N/A N/A N/A Installed No
7. Description of Work Replaced CMnronent/Part/ApMurtenance Additional Description Replaced snubber on hanger I MCA-SM- 182
8. Tests Conducted: Hydrostatic r Pneumatic r Nominal Operation Pressure r Exempt 7l Other r Pressure PSI Test Temp. _°F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 34 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1593-01.00 Support/Restraint Sketch/Drawing No(s).: 1MCA-SM- 182 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date September 20 ,2021-1 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period 7" "./ to .. 2ZP7 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the spector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. JF Swan ,- - Commissions NB11473-NC1524, N-I A Inspector's Signature *National Board, State, Province, and Endorsements Data I?-3-* t ,20/

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas. LLC .. ....... ... ... ..... Date 8/30/2010
                 .5.26 South Church Street,. Charlotte, NC,. 28201                    _                              - *.Sheet      I        of 2 Address
2. Plant McGuire Nuclear .Station Unit I Name 12700 Hagers Fe .Road,_Huntersvil e, NC 28078 1794939-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc,)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte NC 28201-10.Q_6_

Address Expiration Date: N/A

4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME IIl 19 7L Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the. 1.999._and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, AS ME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-ND-273 Duke Energy .21189 N/A N/A N/A Removed No IMCA-ND-273 Duke Energy 37222 N/A N/A N/A Installed No

7. Description of Work Rel ilaced Component/Part/Appurteniance Additional Description re placed snubber on hanger I1MCA-ND-273.
8. Tests Conducted: Hydrostatic F Pneumatic r Nominal Operation Pressure r Exempt F" Other F Pressure -PSI Test Temp. _

Description (Optional):

FORM NIS-2 OWN ER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 8 in. (nominal) System Class: ASME Class2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1561-01.00 Support/Restraint Sketch/Drawing No(s).: IMCA-ND-273 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NDA-002 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date August 30 ,2010 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period 5ý- L-sL- 16 to *- -2L/-, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the I pector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising froA or connected with this inspection. JF Swan *, , E -.- -- .Commissions NC 1524, N-I Inspector's Signatur National Board, State, Province, and Endorsements

FORM NIS-2 OWNER'S REPOI 'T FOR REPAIR/REPLACEMENT ACTIVITY As Required by the I provisions of the ASME Code Section Xi

1. Owner Duke EnergCaroinas, LLC Date 7/13/2010 52_6 SouthChurch .Street. CharlotteNC 28201 Sheet I of 2 Address
2. Plant McGuire Nuclear Station Unit I Name 12700 Ha feryR o __untersyiJle NC 28078. 1794941-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke EnpergyCarolinas_,LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South.ChurchStreet. CQhajLott(. NC 2820_1.- 1006 Address Expiration Date: N/A

4. Identification of System CF- Feedwater
5. (a) Applicable Construction Code ASME 111 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed. or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-CF-201 Duke Energy 20436 N/A N/A N/A Removed No IMCA-CF-201 Duke Energy 37231 N/A N/A N/A Installed No

7. Description of Work Rep laced .Comlonent!Part/A ppurtenance Additional Description Replaced snubber on hanger I MCA-CF-201
8. Tests Conducted: Hydrostatic F Pneumatic r- Nominal Operation Pressure r Exempt F Other r- Pressure PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet of 2 Component Line Size: 18 in. (nominal) System Class: ASMEClasso2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1591-01.01 Support/Restraint Sketch/Drawing No(s).: IMCA-CF-201 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-CFC-012 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date July 13 ,20 10 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period Lrz.17- -/Z0 to # and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Own0r's Report. Furthermore, neither tr nspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro// or connected with this inspection JF Swan U-, X,_ Crommisinns NC1524. N-I inspector's Signatudre - / National Board, State, Province, and Endorsements iatJ I7- ý-2 20-Lo

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI I. Owner Duke Enpergy.Carolinas_. _C .Date 7/13/2010 Charlotte, NC. 28201 .. . .... . Sheet 1 of 2 526 South Church Street. Address

2. Plant McGuire Nuclear Station Unit !

Name 12700 Hagers.Eerry Rpa4d Huntersville NC.28078 1794942-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)

3. Work Performed by Duke Energy Carglinwa, LLC Type Code Symbol Stamp:

Name Authorization No.: 526 South Church StreetLChariotte. NC 28201-1 0.06. Address Expiration Date:

4. Identification of System CF- Feedwater
5. (a) Applicable Construction Code ASME III 19.1 Edition, Summer and Winter Addenda, 'N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 199Edition with. the 1999-and 2000 Addenda.

(c) Applicable Section XI Code Case(s) N/A

6. Identification of Com onents Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-CF-201 Duke Energy 22362 N/A N/A N/A Removed No 1MCA-CF-201 Duke Energy 37221 N/A N/A N/A Installed No

7. Description of Work R~z-keiace4Component/Prit/AAPPurte~nance Additional Description Replaced snubber on hanger IMCA-CF-201I
8. Tests Conducted: Hydrostatic - Pneumatic J" Nominal Operation Pressure -- Exempt F" Other r" Pressure PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 18 in. (nominal) System Class: ASME .Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1591-01.01 Support/Restraint Sketch/Drawing No(s).: IMCA-CF-201 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on N IS-2 Form: MCSRD-CFC-012 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date July 1310 Owner or Owner's Designee, Title I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period 7-/O)to

        -'7-                           _-16ý12                      and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owne s Report. Furthermore, neither the I spector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro ,r connected with this inspection. iF Swan Y Inspector's Signature Commissions NC1524, N-I National Board, State, Province, and Endorsements I

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner fluke I~neivv Carolinas U £C Date 7/15/2010 Duke En fyv C olinas L 526 South Church Street. Charlotte, NC. 28201 Sheet I of 2 A AA
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1794967-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Enery Carolinas, LLC Type Code Symbol Stamp:

Name Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date:

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed ition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped ComponentName of Manufturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-NV-498 Duke Energy 21407 N/A N/A N/A Removed No IMCA-NV-498 -Duke Energy 37853 N/A N/A N/A Installed No

7. Description of Work Rel ilaced Component/Part/Aonpurtenance Additional Description Reeplaced snubber and it's bolting material on hanger 1MCA-NV-498
8. Tests Conducted: Hydrostatic - Pneumatic F Nominal Operation Pressure F Exempt F Other F Pressure PSI Test Temp. _OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions ofthe ASME Code Section XI 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 2 in. (nominal) SystemClass: ASMEClass2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-I 554-03.00 Support/Restraint Sketch/Drawing No(s).: 1MCA-NV-498 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NVK-002 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist c 'j " Date July 15 ,20 10 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

        -       " U             to      2 - /i5L'ZŽ'and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective.

measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector r his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from oflkonnected with this inspection. JF Swan U L , . /? .C.

                                                                      -e--..-.4                            rnmiminne NC1524 N-I Inspector's Signature                                                            National Board, State., Province, and Endorsements ODate                  7                             , 20L0

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X!

1. Owner Duke Energy Carolinas, LI C . Date 5/4/2011 526 South Church Street, Charlotte, NC, 28201 Sheet I of .2 Address
2. Plant McGuire Nuclear .Station Unit 1.

Name

                          .12700 .Hagers Ferry.oad,.HIuntersville,.NC 28078                                         1794990-01 Address                                                                  Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South. Church.Street,. Charlotte, _NC 28201-10.0.6 Expiration Date: N/A Address

4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME 111 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the. 1999and 2000. Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component of Manucturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-ND-271 Duke Energy 17997 N/A N/A N/A Removed No IMCA-ND-271 Duke Energy 38387 N/A N/A N/A Installed No

7. Description of Work Replaced Component/Part!Appurtenance Additional Description R eplaced snubber on hanger IMCA-ND-271I
8. Tests Conducted: Hydrostatic F Pneumatic I- Nominal Operation Pressure F Exempt F Other F Pressure PSI Test Temp. _ I°F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions or the ASME Code Section XI 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 8 in. (nominal) System Class: ASME Class.2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1561-01.00 Support/Restraint Sketch/Drawing No(s).: 1MCA-ND-271 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NDA-006 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist , Date May 4 ,201L Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

           ;-'- Z/j               to    -S--5--//                   , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro/. or connected with this ins ction. JF Swan -,-r ^- 12:;---l , - Commissinns NBI1473-NC1524, N-I Date 6K -- Inspector's Signaiu w ,j 20o/ National Board, State. Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas, L LC Date 9/25/2011 526 South Church Street. (Charlotte, NC, 28201 Sheet I of 2 A AA...
2. Plant McGuire Nuclear Station Unit I Name 12700. Hagers Ferry Road, Huntersville, NC 28078 1810883-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street. Charlotte, NC 28201-1006 Address Expiration Date:

4. Identification of System NI - Safety Injection
5. (a) Applicable Construction Code ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Comp onents Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1NI-19 Flowserve ADFI-1 1 5698 V File# 380 1975 Corrected Yes
7. Description of Work Add New Component/Part/Aopurtenance/Weld Additional Description Se al weld cover to body of valve INI- 19.
8. Tests Conducted: Hydrostatic r Pneumatic -" Nominal Operation Pressure F Exempt r- Other F- Pressure _ PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 1 1/2 in. (nominal) System Class: ASME Class I Weld Isometric Drawing No(s).: MCFi IN149 Flow Diagram No(s).: MCFD-1562-01.00 Support/Restraint Sketch/Drawing No(s).: MCSRD-NI-13 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCM 1205.01-0031.001 & MC-1414-09.20-00 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist M-.... Date September 25 20 11 Owner or Owner's Designee. Title I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

.ConnecticutA
            ,_._-,_,,_                           __        _have                inspected the components described in this Owner's Report during the period
                            -,./Ito                           ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro or connected with this inspect. JF Swan[ ]Commissions NB11473-NC1524, N-I National Board, State, Province, and Endorsements DatC -Z- 20

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi I. Owner fluke Pnerov (~rn1in~tq 1.1AC Date 9/25/2011 Duke En ov Carolin Ll 526 South Church Street. Charlotte, NC, 28201 Sheet I of 2 526 South Church Address St et-

2. Plant McGuire Nuclear Station Unit I Name 12700 Hapers Ferry Road, Huntersville, NC 28078 1810884-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas. LLC Type Code Symbol Stamp: N/A Name Authorization No.: N/A 526 South Church Street. Charlotte, NC 28201-1006 Address Expiration Date: N/A
4. Identification of System NI - Safety Injection
5. (a) Applicable Construction Code ASME III 19271 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected. ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

INI-17 Flowserve ADFI-9 5720 V File# 387 1975 Corrected Yes 1 4. 4 4 4 4 8 4 4 4. + 4 4 4 4 4. .t 4. 4 4 4 1 4. 4 4. 1 4. 1 a .. .5. 1 .5. 5

7. Description of Work Adi 1New Component/Part/Appurtenance/Weld Additional Description Se al weld cover to body of valve INi-17.
8. Tests Conducted: Hydrostatic - Pneumatic r Nominal Operation Pressure F-' Exempt r Other r Pressure PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 1 1/2 in. (nominal) System Class: ASME Class I Weld Isometric Drawing No(s).: MCFI IN164 Flow Diagram No(s).: MCFD-1562-01.00 Support/Restraint Sketch/Drawing No(s).: MCSRD-NI- 14 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCM 1205.01-0031.001 & MC-1414-09.20-00 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist . Date September 25 20 11 Owner or Owner's Designee, Title I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

   `7 - Z                    to        -                         and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the nspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. JFCommissions NB 1473-NC 1524, N-I I"lnspector's Signature .1-1/ National Board, State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner fluke Fner~v Cnrnlinas IA L bC-Date 9/25/2011 Duke Energv C olin 526 South Church Street. Charlotte, NC, 28201 Sheet I of 2 Address
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hazers Ferry Road. Huntersville, NC 28078 1810887-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A

4. Identification of System NI - Safety Injection
5. (a) Applicable Construction Code ASME III 1921_ Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed ition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

INI-347 Flowserve ADFI-14 5701 V File# 380 1975 Corrected Yes

7. Description of Work Ad4dNew Component/Part/Appurtenance/Weld Additional Description Se al weld cover to body of valve IN 1-347.
8. Tests Conducted: Hydrostatic F Pneumatic F Nominal Operation Pressure F Exempt r Other F Pressure PSI Test Temp. _OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions ofthe ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet. 2 of 2 Component Line Size: I 1/2 in. (nominal) System Class: ASME Class 1 Weld Isometric Drawing No(s).: MCFI 1N164 Flow Diagram No(s).: MCFD-i562-01.00 Support/Restraint Sketch/Drawing No(s).: MCSRD-NI-14 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCM 1205.01-0031.001 & MC-1414-09.20-00 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date September25 _,201L Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

.. ii.          ~/(       , -to             --     o                 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither th spector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. JF Swan K-,- --.- Commissions NBI1473-NC1524, N-I

                     *Inspector's Signature   "f                                                   National Board, State, Province, and Endorsements Date~         ~     602                            /

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

1. Owner Duke Energv Carolinas, LILC Date 10/10/2011 526 South Church Street, (Charlotte, NC. 28201 Sheet I of .2
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1857897-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke EnervY Carolinas, LLC Type Code Symbol Stamp:

Name Authorization No.: 526 South Church Street, Charlotte, NC 2820 1-1006 Address Expiration Date:

4. Identification of System NS - Containment Spray
5. (a) Applicable Construction Code - 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Cornponent Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1NS36 Kerotest FW8-14 6730 V File# 514 1975 Installed Yes
7. Description of Work Replaced Component/PartlAppurtenance Additional Description Replaced disc in valve 1NS36.
8. Tests Conducted: Hydrostatic Pneumatic F- Nominal Operation Pressure F'7 Exempt r- Other F" Pressure PSI Test Temp.

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: MCFI-INS42 Flow Diagram No(s).: MCFD-I 56-3-01.00 Support/Restraint Sketch/Drawing No(s).: N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date October 10 ,2011_._ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

  .&-L.3  .       .. t" .         to &./L_-//-/ 1L             .. , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neitherA Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from r connected with this inspecti Commissions NBI 1473-NC1524, N-I

                      /

Inspector's

                           ]      Signature,,-00National                                                   Board. State, Province, and Endorsements DateU           /        -       /                       ,20.d

FORM NIS-2 OWNER'S REPORT FOR REPATRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Enerv Carolinas. LILC Date 10/11/2011 526 South Church Street, Charlotte, NC, 28201 Sheet I of 2 Address
2. Plant McGuire Nuclear Station Unit 1 N'amie 12700 Hagers Ferry Road, Huntersville, NC 28078 1864150-23 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street, Charlotte, NC 28201-1006 Expiration Date: N/A Address

4. Identification of System RN - Nuclear Service Water
5. (a) Applicable Construction Code ASME 1I1 I 971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

RN Piping Duke Energy N/A 36 N/A 1981 Installed Yes

7. Description of Work Replaced Component/Part/Appurtenance Additional Description
8. Tests Conducted: Hydrostatic F Pneumatic F Nominal Operation Pressure f" Exempt F Other F Pressure 90.5 PSI Test Temp. 95.2 oF Description (Optional): Test performed per procedure MP/0/A/7650/076).

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 6 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1574-04.00 Support/Restraint Sketch/Drawing No(s).: N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: EC99750 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date October 11 ,20 11. Owner or Owner's Designee, Title CERTI FICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

  !-- )6-./'/                    to "-/ -- 1.3A/I/*,                and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspectio JF Swar-, ,*- * 'Commissions .NBI 1473-NC1524, N-I Inspector's Signature .National Board, State, Province, and Endorsements Dat .20/4

                                                         --- w

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner Duke Ener"v Carolina. .I L1LC Date 10/14/2011 526 South Church Street, Charlotte, NC. 28201 Sheet 1 of 2 Address
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1867772-03 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Type Code Symbol Stamp: N/A Name Authorization No.: N/A 526 South Church Street Charlotte, NC 28201-1006 Address Expiration Date: N/A
4. Identification of System NS - Containment Spray
5. (a) Applicable Construction Code ASME I.. 1971. Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Cornponents Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1NS64 'Kerotest OM15-1 .12514 N/A 1976 Installed Yes J.+
7. Description of Work Replaced Compient/Part/AvNurtenance Additional Description Replaced disc in valve I1NS64.
8. Tests Conducted: Hydrostatic 17 Pneumatic F Nominal Operation Pressure F Exempt " Other " Pressure PSI Test Temp. _ OF Description (Optional): test performed per procedure MP/0/A/7700/045.

FORM N1S-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X!

9. Remarks (Should Include the Following Information, as Applicable): 2 of 2 Sheet Component Line Size: 2 in. (nominal) System Class- ASME Class 2 Weld Isometric Drawing No(s).: MCF-I1N543)

Flow Diagram No(s).: MCFD- 1563-01.00 SupportfRestraint Sketch/Drawing No(s).: N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed -FL Grass, Quality Assurance Technical Specialist Date October 14 2011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by.:Hartford Steam Boiler Inspection and Insurance Company of

Connecticut have inspected the components described in this Owner's Report during the period 2i -- 2.*L-- .. to Z. * -Zi / ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owne 's Report. Furthermore, neither the spector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fror br connected with this inspection. JF Swan ( ,.7 Inspector's Signature

                                            /7       /       &)--,-                                 Commissions NBI1473-NC1524, N-I National Board, State, Province, and Endorsements

ýDatea - zo - Z7 20&! Date~~j. 20//

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner flida~ Fn~r~~v Cs'erolinac 1.1LC Date 10/5/2011 Duke En-v Carolinas L 526 South Church Street. Charlotte, NC, 28201 Sheet I of 2 526 South Church Address Street
2. Plant McGuire Nuclear Station Unit I1 Name 12700 Haaers Ferry Road, Huntersville, NC 28078 1878522-20 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Type Code Symbol Stamp: N/A Name Authorization No.: N/A 526 SmithChurch ddressCaltt.N 82110 Address Expiration Date: N/A
4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME III 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edlition with the 1999 and 2000 Addenda ition with the 1999 and 2000 Addenda L

(c) Applicable Section XI Code Case(s) N/A

6. Identification of Components Corrected, ASME Code Namenof Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-ND-333 Duke Energy N/A N/A N/A N/A Corrected No

  • 1* 1- 1* F 4~ F F 4. I
                          &                                I.                           4*                       4.                                   4                                     1 I                                4.                           4.                       4.                                   I         4                           I
7. Description of Work Replaced Component/Part/Appurtenance Additional Description R(eplaced pipe clamp on hanger IMCA-ND-333 due to operator change out on valve INDI5.
8. Tests Conducted: Hydrostatic r Pneumaticr- Nominal Operation Pressure F Exempt P- Other r Pressure PSI Test Temp. _IF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 8 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1561-01.00 Support/Restraint Sketch/Drawing No(s).: 1MCA-ND-333 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NDA-001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist - C Date October 5 ,20!I1 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period q-- _0 - I I to / , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the I pector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. IF Swan -Commissions NB11473-NC1524, N-I SInspector's Signature National Board. State, Province, and Endorsements Date 0 - ,20L

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner . Duke Energi C:arolinas,, L L-C. ... Date 6/24/2010 526 South Church Street._ _Charo.tteNC,_2201........ ....... Sheet I of 2 Address
2. Plant McGuire Nuclear Station Unit 1.

Name

                           .27.00 -agrs Ferr       o       uteryile,.NC 28078                                          1892748-01 Address                                                                  Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energ.Carolina__L.L .

Name Type Code Symbol Stamp: Authorization No.: 526 South Church StreeeL Charlotte. NC 28201-1006 Address Expiration Date:

4. Identification of System SV - Main Steam Vent to Atmosphere
5. (a) Applicable Construction Code ASME I1 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addends (c) Applicable Section XI Code Case(s) N/A
6. Identification of Compnonents Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

ISV-1AB Babcock-Wilcox 15958-2-1 1075 N/A 1977

7. Description of Work Replaced Component/Part/Appurtenance Additional Description placed plug assembly in valve ISV-IAB.
8. Tests Conducted: Hydrostatic F Pneumatic r- Nominal Operation Pressure P" Exempt F Other IF Pressure PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): 2 of 2 Sheet Component Line Size: 6 in. (nominal) System Class: ASME C1ass2 Weld Isometric Drawing No(s).: MCFI-SV-2 Flow Diagram No(s).: MCFD- 1593-01.03 Support/Restraint Sketch/Drawing No(s).: N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on N IS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist *'*i* Date June, 24 .20 10 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

*Connecticut                                                                    have inspected the components described in this Owner's Report during the period 2
      -Z "       -6              to 12- c .,                         and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor h'employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' eport. Furthermore, neither the I ector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from r onnected with this inspection Swan /F C,,ommisins NC1524-N-I 7 Inspector's Signature ' National Board. State, Province, and Endorsements Date 20/&2 L/

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas, L LC Date 9/28/2011
                  ~6 Smith Chiimh Street Ch~rIotte NC. 28201                                                                           of 2 Sheet .I Address
2. Plant McGuire Nuclear Station Unit I Name 12700 Haiers Ferry Road, Huntersville, NC 28078 1897294-12 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke EneraW Carolinas. LLC Name Type Code Symbol Stamp:

Authorization No.: 526 Soh Church Street.ICharlotte. NC 28201-1006 Address Expiration Date: 'N'1

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME III 19-1L Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped ComponentName of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

NV Piping Duke Energy N/A 37 N/A 1981 Installed Yes

7. Description of Work Replaced Component/Part/Appurtenance Additional Description Rt placed bolting in flange INVFE533Q.
8. Tests Conducted: Hydrostatic F" Pneumatic '- Nominal Operation Pressure F'T Exempt r- Other r Pressure _PSI Test Temp. _ IF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: MCFI-INV5 Flow Diagram No(s).: MCFD-1554-01.01 Support/Restraint Sketch/Drawing No(s).: MCSRD-NVA Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist N', ,,- Date September 28 , 20 11 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period _to Z and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' seport. Furthermore, neither th nspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o nnected with this inspection. JF Swan Commissions NB11473-NC1524, N-1 Inspector's Signature " ' / National Board, State, Province, and Endorsements Date r- 3-P - 20//

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energv Carolinas.I LI LC Date 10/16/2011 526 South Church Street. Charlotte. NC, 28201 Sheet I of 2 Address
2. Plant McGuire Nuclear Station Unit I Name 12700 Halzers Ferry Road, H-untersville, NC 28078 1905977-02 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street. Charlotte, NC 28201-1006 Expiration Date: N/A Address

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME 111 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

INV155 Dresser TE09048 292 N/A 1978 Removed Yes INVI55 *Dresser TE09049 293 see description below 1978 Installed Yes

7. Description of Work Replaced Comronent/Part/Alpurtenance Additional Description Replaced relief valve INV 155.
8. Tests Conducted: Hydrostatic r- Pneumatic rT Nominal Operation Pressure P- Exempt r- Other F- Pressure 'PSI Test Temp. °F Description (Optional): This valve was from original construction equipment installed at valve 2NV155 location (NB# 80, YB 1982 for NV System)

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions ofrthe ASMIE Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 4 x 6 in. (nominal) 5' stem Class: ASME Class 2 Weld Isometric Drawing No(s).: MCFI- NV34 Flow Diagram No(s).: MCFD- 1554-02.01 Support/Restraint Sketch/Drawing No(s).: N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date October 16 ,20,)1H Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of __Connecticut have inspected the components described in this Owner's Report during the period qL 3c>-. Z to /0 . , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section X1. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. JF Swan = Commissions NBI1473-NC1524, N-I Inspector's Signature .National Board. State. Province, and Endorsements e /0iseco' -ignature1/

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

1. Owner Duke Energy Carolinas,. L C. Date 7/22/2010 526 South Church Street,- Charlotte,.NC, 28201 ...... . Sheet I of 2 Address
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferrrv Road, Huntersville, NC 28078 1911887-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Type Code Symbol Stamp: N/A Name Authorization No.: N/A 526 South Church*Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A
4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME 111 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section Xl used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected. ASME Code Name of Manufacturer National Other Year Removed. or Stamped ComponentName of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-NV-435 Duke Energy 19881 N/A N/A N/A Removed No IMCA-NV-435 Duke Energy 37048 N/A N/A N/A Installed No

7. Description of Work Replaced Cosmponent/Part/Appurtenance Additional Description R( ~placed snubber on hanger IMCA-NV-43 5.
8. Tests Conducted: Hydrostatic F Pneumatic r- Nominal Operation Pressure r" Exempt F" Other F- Pressure PSI Test Temp. __

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1554-0'3.00 Support/Restraint Sketch/Drawing No(s).: IMCA-NV-435 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NVA-006 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist - f Date July 22 20 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period 7 t o, 7" 2 $ -" and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither t Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro or connected with this inspection JF Swan* "Commissions NC 1524, N-I aNational Board, State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Fner~v Carolina.~ L LILC Date 10/18/201.1 Duke Enerav Carolinas 526 South Church Street. Charlotte, NC, 28201 Sheet I of 2
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1917396-13 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energv Carolinas. LLC Type Code Symbol Stamp:

Name Authorization No.: 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: '"'

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME II1 1971. Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected. ASME Code Nameof Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

Excess Letdown HX Atlas Industrial 1809 1554 N/A 1972 Installed Yes

7. Description of Work Reolaced Comlonent/Part/Alpourtenance Additional Description Replaced bolting material on Excess Letdown Heat Exchanger.
8. Tests Conducted: Hydrostatic r- Pneumatic F Nominal Operation Pressure P Exempt r- Other F Pressure .PSI Test Temp. __ F Description (Optional): test performed per procedure MP/0/A/7700/045.

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1554-01.02 Support/Restraint Sketch/Drawing No(s).: N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCM-1201.26-0007.001 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist N.Z'A4, Date October 18 ,20 11 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period

   -'ý - 90L-./                  to                                  and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither the Inspetar nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. JF Swan a .p . ,Commissions NBI1473-NCI524,NN-! S Inspector's Signature J "National Board, State, Province, and Endorsements DateoZC

      &                                                ,2-

FORM NIS-2 OWNER'S REPOR T FOR REPAIR/REPLACEMENT ACTIVITY As Required by the P rovisions of the ASME Code Section XI

1. Owner . Duke Eneirg CaroJinas. LLC.
                                                                                        ------...              _____-    Date 9/2/2010 526 South Church Street,. CharlotteNCQ 28201 .                      ........ ...... . .                Sheet    I        of 2 Address
2. Plant McGuire Nuclear Station Unit 1.

Name 12700 Hag~ers Ferr RoadHuntersyville, NC2.8078 .!. 191I8405-01 Address 1918405-01 Unit Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)

3. Work Performed by Duke. Energy Carolinas_ LLC.

Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street,..h;arlohtQ. NC_28201 -.!006-Address Expiration Date: N/A

4. Identification of System ND - Residual Heat Removal
5. (a) Applicable Construction Code ASME II1 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCA-ND-327 Duke Energy 6696 N/A N/A N/A Removed No IMCA-ND-327 Duke Energy 37056 N/A N/A N/A Installed No

7. Description of Work Replaced Coomponent/Par't'Appurtenance Additional Description Rteplaced snubber on hanger I MCA-ND-327.
8. Tests Conducted: Hydrostatic " Pneumatic F" Nominal Operation Pressure F Exempt FP Other IF Pressure -PSI Test Temp. __-IF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2 of 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet Component Line Size: 8 in. (nominal) System Class: ASMEMClass02 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1561-0l .00 Support/Restraint Sketch/Drawing No(s).: I MCA-ND-327 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist , "Date September 2 -,201. Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period S .5 - ,/C to 9 , ) ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither th nspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o onnected with this inspection. JF Swan Commissions NC1524, N-I Inspector's Signature "National Board, State. Province, and Endorsements Date6/,/ 20-Z

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Enerqv Carolinas. LI AC Date 9/27/2011 Charlotte, NC, 28201 Sheet I of 2 526 South Church Street
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagem Ferrv Road_ Huntersville- NC 28078 1919132-18 Address Work Order # (or RepairfReplacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte. NC 28201-1006 Address Expiration Date: N/A
4. Identification of System NS - Containment Spray
5. (a) Applicable Construction code ASME 111 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section X1 used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section X1 Code Case(s) N/A
6. Identification of Cornmonents Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCR-NS-767 Duke Energy N/A N/A N/A N/A Installed No

                         .5.                                4                          4                        4                                    .5.         1                         .5.
                         +                                  4                          I                        4                                    4          1                          .5.
                         +                                                             I                        4                                    4          4                          4
7. Description of Work Replaced Component/Part/Appurtenance Additional Description Replaced hanger I MCR-NS-767 with new support.
8. Tests Conducted: Hydrostatic - Pneumatic '- Nominal Operation Pressure " Exempt r7" Other F" Pressure PSI Test Temp. _ °F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet of 2 Component Line Size: 8 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1562-03.01 Support/Restraint Sketch/Drawing No(s).: IMCR-NS-767 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: MCSRD-NS-06-002, EC101539 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date September27 20-1l Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period Yto _ " 7(?- and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspe r nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from oEconnected with this inspection. JF Swan , 'Commissions NB 11473-NC 1524, N-I Inspector's Signatur .National Board, State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Qaroninasj_L L,_ ---....-.. .. .. . --.... .. . .. .... ..... D ate 9/2 8/20 10 526. South Church Street.( Charlotte,_NC, 282.01... . ..... .......... Sheet 1 of 2 Address
2. Plant McGuire Nuclear Station Unit i Name 12700 Hagers Frrry o unte~rsy ill.NC2-8078 .1919840-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke .Energy Carro~Ljas_,LLC Name Type Code Symbol Stamp: N/A Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A
4. Identification of System VI - Instrument Air
5. (a) Applicable Construction Code ASME I1 19 71 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section X1 used for Repair/Replacement Activity 1998 Edition with the_1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected. ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IVI149 Kerotest ADF7-11 6570 N/A 1975 Installed Yes

7. Description of Work Replaced ComponentlPart/Appurtenance Additional Description Replaced disc in valve IV1149.
8. Tests Conducted: Hydrostatic Pneumatic F Nominal Operation Pressure F1 Exempt F Other F' Pressure PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X!

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: MCFI-IV122 Flow Diagram No(s).: MCFD- 1605-01.02 Support/Restraint Sketch/Drawing No(s).: N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist # Date September 28 ,2010 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

'Connecticut have inspected the components described in this Owner's Report during the period e-!1        , -/0Z               to 9 - a?'-
  • 1and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owher's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from *connected with this inspection. JF Swarl G ,7 . Commissions NC1524, N-1 Inspector's Sign:ature I'l National Board, State, Province, and Endorsements Date 9- 2 L- 20L I,

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI I. Owner Duke Enerav Carolinas. Li LC Date 10/15/2011 526 South Church Street. Charlotte, NC. 28201 Sheet I of 2 Address

2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1919840-09 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No.. etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp: NfA Authorization No.: N/A 526 South Church Street. Charlotte, NC 28201-1006 Address Expiration Date: N/A
4. Identification of System VI - Instrument Air
5. (a) Applicable Construction Code ASME 111 1971L Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected. ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1VI 149 Kerotest ADF7-11 6570 N/A 1975 Removed Yes IVI149 Velan 111030 N/A N/A 2011 Installed Yes
7. Description of Work Replaced Component/Part/Appurtenance Additional Description Cut out and replaced valve I VI 149 per ECI 03658.
8. Tests Conducted: Hydrostatic r- Pneumatic F" Nominal Operation Pressure Exempt r" Other '- Pressure 100 PSI Test Temp. 74.7 OF Description (Optional): test performed per procedure MP/0/A/7650/076.

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: -) - in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: MCFI-IV122 Flow Diagram No(s).: MCFD-l605-0l .02 Support/Restraint Sketch/Drawing No(s).: N/A Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form: ECI03658 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A 4 Signed FL Grass, Quality Assurance Technical Specialist " bSt¢." Date October 15 _ 20 11 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the components described in this Owner's Report during the period z7L./.z/(/ to ./.Q-1(- // , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described 4 in this Owner's Report. Furthermore, neither the l spector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection. JF Swan b-A-= /.i .I2,,=., Commissions NBI1473-NC1524,N-I Inspector's Signature' National Board. State. Province. and Endorsements Dat( -)0-A

09/20/11 TUE 07:23 FAX QA LAB Q 002 111030 FORM NPV-1 CERTIFICATE HOLDER'S DATA REPORT FOR NUCLEAR PUMPS OR VALVES As Required by the Provisions of the ASME Code, Section III, Division I pg. 1 of2

1. Manulactured and certified by VELAN INC. 2125 WARD AVEMONTREAL.QUEBEC CANADA H4M1 T6

{nan and adldrmofN Cetificate hddur)

2. Manufactured for DUKE ENERGY, PO BOX 37025. CHARLOTTE, NC. 28237-7925. UNITED STATES (narme asd PuRatir) and address DUKE ENERGY, MCGUIRE NUCLEAR STATION, 13225 HAGERS FERRY RD, HWY 73.
3. Location of installation HUNTERSVILLE. NO. 28078-8985. UNITED STATES (oams'emd nddrnis)

PISTON

4. Model No., Series No., or Type CHECK Drawing Pal 1-856478-NOI Rev. CRN N/A
6. ASME Code, Section I11, Divislon 1 1989 'NONE LloCs NIA.
6. Pump or valve VALVE Nominal Inlet siie 2" Outlet size i 2"
7. Material-SA4564, GR 630 HI 100.

(a) valve Body SA-182, F316 Bonnet SA-1-82, F316 Disk SFA6.21,ERNiCr-A Bolting SA-194, GR 8M (b) pump Casing NIA Cover -- N/A Bolting NIA (a) (b) (c) (d) (e) Certificate National Body/Casing Bonnet/Cover Disk Holder's Board Serial Serial Serial Serial No. No. No. No. No. 111030V N/A MMCAF1 MMOYV2 V* 05-7O 14 ___ I

                                                                                                                                                       -  -~                      I
   'Supplem~ental informstlon In the form of Ilets, sketches.. ofdrawings -nca5 cei 4 pcaviled: ( 1)size is 5%A  %11; (2) information inttnimsI through 4dan this Data Revort is itictaided on each sh'eet; and (3) each sheet is numbered and Ihe r,,anhnt of sheets IsfeCCore~d at the to of thi~s form.

(07110)

                                                                                             '4355                                     JPGE 3OF,ý:J-

09/20/11 TUE 07:23 FAX QA LAB FORM NPV-1 (Back - Pg. 2 of .2.) Certificate HDoder's Sefrii No- 111030

8. Design conditions Ii5 psi vs 250 OF or valve pressure Cdass 800
9. Cold working pressure 1920 psI at 100 'F
10. Hydrostatic test 2900 pal. DIsk differential lesit pressure 21_50 psi 11, Remarks MATERIALS MEET ASME SECTION II EDI1ION: 2004 ADDENDA: NONE CERTIFICATION OF DESIGN Design Specification certified by JAMES M. LAMB. JR. P.E. Slate NC Reg. no. 6005NC Design Report certified by P.MA.IOR P.E. Slate QUE Reg. no. 37162 CERTIFICATION OF COMPLIANCE We cerd~fy that the statements made In this report am correct and that this pump or valve conforms to the rufes for construction of the ASMF- Code, Section 111. Division 1.,j"AT2-*--,21 N Ceriffi'ate of Authorization No. N-2797-1 - Expires -- ýU a 21 CERTIFICATION OF INSPECTiON I, the undersigned, holding a valid commimion Issued by t11e National Board of Boiler and Pressure Vessil Inspectors and the State or Province of QUEBEC and employed by REGIE DU BATIMENT of QUEBEC have inspected the punp, or valve, described In this Data Report on
                         ,and state that to the best of rnv knowledge and belief. the Certificate Holder has constrcted this pump, or valve, in accordance with the ASME Code. Section III. Division 1.

By signing this certlicato neither the Inspector nor his einpkoyer makea any warranty, expressed or Implied, oncernlng the component described In this Data Report Furthermore, nai" khe I-pciprho. .. f hr. employer shall be labe In any manner for any ejsnlnjury or property damage or a loss of any kind arsi*

  • or conillt rdeclon. C.s
                                                                                                   .  .. r'.' '            C
                                                                                                                           , k.

Datle 1 5SEP. 7111 Signed Z , ,.- CommissIons ... .G -=QJEBSC U Q1B, 6(l 4355 PG

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Eneray Carolinas, L LC -Date 10/10/2Oi1
                  ~,96 Sniith Church Street  Charlotte, NC, 28201                                                    Sheet    I        of 2 526 South Church Street AAA
2. Plant McGuire Nuclear Station Unit 1 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1919897-01 Address 1919897-01 Work Order # (or Repair/Replacement Organization P.O. No.. Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 XT/ A Address Expiration Date:

4. Identification of System NV - Chemical & Volume Control
5. (a) Applicable Construction Code ASME Ill 192L Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)
,1NV220                     Dresser                         TE57945                     1739                     :N/A                                 .1980       Removed                         Yes I1NV220                    Dresser                         TG33979                     1884                      MC24681                              1984        Installed                      Yes I                        I                                    .L          A.                         -,
7. Description of Work Additional Description Re placed valve INV220 and it's flange bolting material
8. Tests Conducted: Hydrostatic FT Pneumatic r' Nominal Operation Pressure F Exempt F Other f Pressure PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 1 1/2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1554-03.00 Support/Restraint Sketch/Drawing No(s).: MCFI- I NV4 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. .N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist '...<'/ e.- Date October 10 2011 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of I Connecticut have inspected the components described in this Owner's Report during the period 2C L2.zL41...to /(,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective

                                                         ' - Z,9""/*

measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owne 's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro r connected with this inspection. JF Swan, .Commissions NBI 14733-NC 1524, N-I Inspector's Signature -National Board, State, Province, and Endorsements D te/ 10 -/0O , 20i1/

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

1. Owner Drike Pnei-~v CarA1ina~ Ii L LC Date 10/3/2011 Duke Energv Carolinas 526 South Church Street, Charlotte, NC, 28201 Sheet '1 of :2 A
2. Plant McGuire Nuclear Station Unit I Name 12700 Haiers Ferry Road, Huntersville, NC 28078 1920006-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Enerps Carolinas, LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date:

4. Identification of System NI - Safety Injection
5. (a) Applicable Construction Code ASME IlI 1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected. ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

MCR-NI-702 Duke Energy 21082 N/A N/A N/A Corrected No

7. Description of Work Replaced Cormonent/Part/Appurtenance Additional Description Replaced rear pivot mount on hanger IMCR-NI-702
8. Tests Conducted: Hydrostatic F Pneumatic F" Nominal Operation Pressure F Exempt F Other F Pressure .PSI Test Temp. -

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1562-02.00 Support/Restraint Sketch/Drawing No(s).: 1MCR-NI-702 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date October 3 ,2011 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

 .NorthCarolina                                                                 and employed by Hartford Steam Boiler Inspection and Insurance Company                            of Connecticut                                                                    have inspected the components described in this Owner's Report during the period to         /        -               and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither th Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fromr fconnected with this inspection IJF Swan Commissions NBI 1473-NC 1524, N-I Inspector's Signature National Board, State. Province, and Endorsements Date / D - L/ I 20//

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas, LI1C Date .9/27/2011 526 South Church Street, Charlotte, NC, 28201 Sheet 1 of :2
2. Plant McGuire Nuclear Station Unit 1 Name 12700 1-aters Ferry Road. I-untersville. NC 28078 1922133-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A

4. Identification of System BB - Steam Generator Blowdown Recycle
5. (a) Applicable Construction Code ASME III 19721 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edlition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCR-BB-585 Duke Energy :20731 N/A 1N/A N/A Removed No IMCR-BB-585 Duke Energy 38051 N/A .N/A :N/A Installed No

7. Description of Work Rej placed Component/Part/AIpurtenance Additional Description Re~placed snubber on hanger I MCR-BB-585
8. Tests Conducted: Hydrostatic F Pneumatic r" Nominal Operation Pressure rF Exempt 17 Other F Pressure PSI Test Temp. _ OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI 2

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of Component Line Size: 2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD- 1580-01.00 Support/Restraint Sketch/Drawing No(s).: IMCR-BB-585 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist .. Date September 27 ,20 11 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of tonnecticut have inspected the components described in this Owner's Report during the period

        - a                     to...              z?-L/L/         and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspVction. JF Swan // ,'*-..4iJ2- , Cnmmiszinon NBI 1473-NC 1524,o N-I Inspector's Signature / National Board, State, Province, and Endorsements Da42 qa 20I)1P 20 //

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas, LIL.C Date 1 J0/./201j 526 South Church Street. Charlotte, NC, 28201 Sheet 1 of 2 A AA..,.
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1922134-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date:

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME I1 197L Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Ed ition with the 1999 and 2000 Addenda (c) Applicable Section Xl Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

MCR-INV-548 Duke Energy 19983 N/A -N/A ,N/A Removed No MCR-INV-548 Duke Energy 38409 "N/A/A N/A Installed No

7. Description of Work Replaced Comnonent/Part/AMurtenance Additional Description Re-placed snubber on hanger MCR-lINV-548
8. Tests Conducted: Hydrostatic FT Pneumatic IT Nominal Operation Pressure F Exempt F Other I' Pressure 'PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of. 2 Component Line Size: 2 in. (nominal) System Class: ASMFE Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: .MCFD- 1554-01.01 Support/Restraint Sketch/Drawing No(s).: MCR-INV-548 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist -,,T,4"* Date October 1 ,2011 Owner or Owner's Designee, Tide CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

 ýNorh Carolina                                                              and employed by* Hartford Steam Boiler Inspection and Insurance Company                            of Connecticut                                                                 have inspected the components described in this Owner's Report during the period
  ""                        to"-/-' "                      .t  and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Repr. Furthermore, neither the Inspec nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or co/t/ected with this inspection.

*JF Swan            /                         /         ,-Commissions                                               NBI 1473-NC 1524, N-I
              "    7Inspector's Signature                                                       National Board, State, Province, and Endorsements
                                                             /_/

L

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X!

1. Owner Duke Energv Carolinas. LI LC Date 10/1/2011 2

526 South Church Street., Charlotte, NC, 28201 Sheet I. of Addoress

2. Plant McGuire Nuclear Station Unit 1 Name 12700 Halers Ferry Road, Huntersville, NC 28078 1922135-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Type Code Symbol Stamp: N/A 7 Name Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 . .. . . . NI/A Address Expiration Date:
4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME III .1971 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) 'N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)
-IMCR-NV-1006                    :Duke Energy                           .20707                         .N/A                       N/A                                  N/A       Removed                         No..

IMCR-NV-1006 Duke Energy 37609 :N/A N/A N/A Installed No

             . . .  ...... . .. 1 .  .. ..
7. Description of Work Rep placed Component/Part/Appurtenance Additional Description Re,placed snubber on hanger 1MCR-NV-1006
8. Tests Conducted: Hydrostatic Pneumatic F Nominal Operation Pressure F Exempt F Other r Pressure :PSI Test Temp. _

Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 3 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1554-01.02 Support/Restraint Sketch/Drawing No(s).: 1MCR-NV-1006 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xi. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date October I ,20 111 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina Hartford Steam Boiler Inspection and Insurance Company of NothCaolnaand employed by o iConnecticut have inspected the components described in this Owner's Report during the period 7 c2. '7-il to.i and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspecto or his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from connected with this inspection.

,JF Swan
              .1 9  p,        "..'-' .,.

Inspector's Signature

                                            /                -                                   Commissions NBI 1473-NC1524, N-I National Board. State. Province, and Endorsements Date(J            /0--/

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Enerqv Carolinas. LILC Date .10/9/2011 526 South Church Street, 4Charlotte, NC, 28201 Sheet -I of 2
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1922137-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: "'"

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME III 192L Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)
NV-100-02-S Duke Energy 21437 N/A N/A N/A Removed No NV-100-02-S .Duke Energy 37837 :N/A . N/A N/A Installed No
7. Description of Work Re placed Component/Part/Appurtenance Additional Description Replaced snubber and it's bolting material on hanger I-MCR-S-NV- 100-02-S.
8. Tests Conducted: Hydrostatic F" Pneumatic r- Nominal Operation Pressure FT Exempt r Other r- Pressure _ PSI Test Temp. _F Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X]

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 4 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1554-01.01 Support/Restraint Sketch/Drawing No(s).: 1-MCR-S-NV-100-02-S Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist T Date October 9 ,2011, Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

;Connecticut                                                                have inspected the components described in this Owner's Report during the period
   '7-.    *-'7-        /1 to                        -   /(

A0-/V ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section. XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this OwneA 's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fro r connected with this inspectio Commissions NB11473-NC1524, N-I SInspector's Signature National Board, State, Province, and Endorsements Dal / " /0 . . 2 0./

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas, LI C Date "9121/2011 52t~ ~nith Church Str~.et ( harlotte, NC. 28201 Sheet I of 2 526 South Church Street
2. Plant McGuire Nuclear Station Unit1 Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1922138-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A

4. Identification of System NF - Ice Condencer Refrigeration
5. (a) Applicable Construction Code ASME III 1971. Edition, 'Summer and Winter Addenda, 1N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edlition with the 1999 and 2000 Addenda ition wi the 1999 and 2000 Addenda A

(c) Applicable Section XI Code Case(s) N/A

6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IMCR-S-NF-100-01H.i Duke Energy 163 N/A ..N/A N/A Removed No IMCR-S-NF-100-0 1HH Duke Energy 37836 .N/A N/A N/A Installed No

7. Description of Work Replaced Component/Part/A1Murtenance Additional Description Re~placed sn ubber on hanger IMCR-S-N F- 100-0 1H
8. Tests Conducted: Hydrostatic FT Pneumatic "7 Nominal Operation Pressure r' Exempt FF Other 1" Pressure _ PSI Test Temp. -OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 4 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-1558-04.00 Support/Restraint Sketch/Drawing No(s).: IMCR-S-NF- 100-01 H Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technicai Specialist Date September21 20-1L Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of

'Connecticut__                                                              have inspected the components described in this Owner's Report during the period
  . *i: z
       -- o..LL.../V         to                                  and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this 0 ner's Report. Furthermore, neithe he Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising or connected with this inspect. JF w,-.Commissions NB 11473-NC 1524, N-I

ýate2 q.            Ic
                                                  ,2:                                          National Board, State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X!

1. Owner Duke Enerv Carolinas, LILC Date ;10/1/2011 526 South Church Street- Charlotte, NC, 28201 Sheet i of,2
                               ý AA
2. Plant McGuire Nuclear Station Unit I Name 12700 Hagers Ferry Road, Huntersville, NC 28078 1922139-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC
  • Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street. Charlotte, NC 28201-1006 Address Expiration Date: "-

4. Identification of System NV - Chemical and Volume Control
5. (a) Applicable Construction Code ASME III 1921 Edition, Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Come Manufacturer National Other Year Removed, or Stamped Name of Manufacturer Serial.No. Board No. Identification Built Installed (Yes or No)
.MCR-1NV-972              Duke Energy                                14844                     N/A                                                              N/A /N/A     Removed                      No MCR-INV-972              ýDuke Energy                               38405                      N/A                        .N/A                                 N/A          Installed                    No
                                        ~~~~....                        . .....               1:!......                                 ...........
7. Description of Work Rei ~laced ComponentfPart/Apipurtenance Additional Description R eplaced snubber on hanger MCR- INV-972
8. Tests Conducted: Hydrostatic F Pneumatic 1" Nominal Operation Pressure F Exempt F Other F. Pressure. ____PSI Test Temp. _. .OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of. 2 Component Line Size: 2 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).:NA Flow Diagram No(s).: MCFD-1554-0l .01 Support/Restraint Sketch/Drawing No(s).: MCR-INV-972 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist Date October I ,20_ 1 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

.Nonnethaicut                                                                 and employed by Hartford Steam Boiler Inspection and Insurance Company                             of
.Connecticut                                                                   have inspected the components described in this Owner's Report during the period 7'- L2 r         I- to              U                        , and state that to the best ofmy knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither nspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from r connected with this inspectio JFSwan (I gA... .- ... Commissions NBI 1473-NC1524, N-I Inspector's Signaturo--- 00' National Board, State, Province, and Endorsements Data / r\2c//

                              ~       ~          k  1

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section X1

1. Owner Duke Enerv Carolinas, LI LC Date 10/1/2011 Hntervil282C0207 Sheet 1 of '2 Address Harerst Fhrrload.

12700Crc

2. Plant McGuire Nuclear Station Unit I_

Name 12700 Hagers Ferry Road, Huntersville, NC 28078 .1922155-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)

3. Work Performed by Duke Eneray Carolinas, LLC Name Type Code Symbol Stamp:

Authorization No.: 526 South Church Street, Charlotte, NC 28201-1006 Expiration Date: N/A Address

4. Identification of System :CF - Feedwater
5. (a) Applicable Construction Code ASME III 191L Edition, %Summerand Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edlition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No) 1MCR-CF-404 Duke Energy 33742 N/A N/A N/A Removed No 1MCR-CF-404 Duke Energy 38109 N/A N/A N/A Installed No
7. Description of Work tx~una'.~.~ ,S.~kJA~JSJfl~~,I IL' I at,, flu u,,, Lt.nna,,t,~

Additional Description R( eplaced snubber on hanger I MCR-CF-404

8. Tests Conducted: Hydrostatic " Pneumatic F Nominal Operation Pressure F' Exempt P Other F Pressure ___PSI Test Temp. OF Description (Optional):

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

9. Remarks (Should Include the Following Information, as Applicable): Sheet 2 of 2 Component Line Size: 16 in. (nominal) System Class: ASME Class 2 Weld Isometric Drawing No(s).: N/A Flow Diagram No(s).: MCFD-l591-0l .01 Support/Restraint Sketch/Drawing No(s).: IMCR-CF-404 Other Applicable Information (e.g., W.O. No., EC No.) if not included elsewhere on NIS-2 Form:

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI. Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed FL Grass, Quality Assurance Technical Specialist

  • Date October 1 201-1 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by Hartford Steam Boiler Inspection and Insurance Company of
Connecticut have inspected the components described in this Owner's Report during the period
  '7- ¢2'7. ii/                 to        /      II....../ and state that to the best ofmy knowledge and belief, the Owner has performed examinationsand taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Ownels Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from r connected with this inspectio JF Swan 1/ - Commissions NBI 1473-NC1524, N-I Inspector's Signature /7 - National Board, State, Province, and Endorsements Da(e

                  /D-/                           :, 20//

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Duke Energy Carolinas. LILC Date 10/1/2011 526 South Church Street., Charlotte, NC, 28201 A..IJ .... I Sheet 1 of 2 Address
2. Plant McGuire Nuclear Station Unit I Name 12700 Hapers Ferry Road. Huntersville, NC 28078 1922156-01 Address Work Order # (or Repair/Replacement Organization P.O. No., Job No., etc.)
3. Work Performed by Duke Energy Carolinas, LLC N/A Name Type Code Symbol Stamp:

Authorization No.: N/A 526 South Church Street, Charlotte, NC 28201-1006 Address Expiration Date: N/A

4. Identification of System CF - Feedwater
5. (a) Applicable Construction Code ASME HI 1971 Edition, **Summer and Winter Addenda, N/A Code Case (b) Applicable Edition of Section XI used for Repair/Replacement Activity 1998 Edition with the 1999 and 2000 Addenda (c) Applicable Section XI Code Case(s) N/A
6. Identification of Components Corrected, ASME Code Name of Manufacturer National Other Year Removed, or Stamped Component Name of Manufacturer Serial No. Board No. Identification Built Installed (Yes or No)

IIMCR-CF-403 Duke Energy 3*3793 N/A N/A N/A Removed No 1MCR-CF-403 Duke Energy 38111 ;N/A *N/A N/A Installed No I .

7. Description of Work Ret laced Cominonent/Part/A1urtenance Additional Description Re placed snubber on hanger IMCR-CF-403
8. Tests Conducted: Hydrostatic " Pneumatic r- Nominal Operation Pressure F' Exempt F Other F' Pressure PSI Test Temp. _ OF Description (Optional):}}