| number = ML100970350
| number = ML100970350
| issue date = 04/14/2010
| issue date = 04/14/2010
| title = Hope Creek Generating Station, License Renewal Application - Request for Additional Information for Section 2.2.5, Boral Monitoring Program
| title = License Renewal Application - Request for Additional Information for Section 2.2.5, Boral Monitoring Program
| author name = Ashley D J
| author name = Ashley D
| author affiliation = NRC/NRR/DLR/RPB1
| author affiliation = NRC/NRR/DLR/RPB1
| addressee name = Joyce T
| addressee name = Joyce T
Line 9: Line 9:
| docket = 05000354
| docket = 05000354
| license number =  
| license number =  
| contact person = Ashley D J
| contact person = Ashley D
| case reference number = TAC ME1832
| case reference number = TAC ME1832
| document type = Letter, Request for Additional Information (RAI)
| document type = Letter, Request for Additional Information (RAI)
Line 18: Line 18:


=Text=
=Text=
{{#Wiki_filter:April 14, 2010 Mr. Thomas Joyce President and Chief Nuclear Officer PSEG Nuclear LLC P.O. Box 236 Hancocks Bridge, NJ 08038  
{{#Wiki_filter:April 14, 2010 Mr. Thomas Joyce President and Chief Nuclear Officer PSEG Nuclear LLC P.O. Box 236 Hancocks Bridge, NJ 08038


==SUBJECT:==
==SUBJECT:==
HOPE CREEK GENERATING STATION, LICENSE RENEWAL APPLICATION - REQUEST FOR ADDITIONAL INFORMATION FOR SECTION 2.2.5, BORAL MONITORING PROGRAM (TAC NO. ME1832)  
HOPE CREEK GENERATING STATION, LICENSE RENEWAL APPLICATION -
REQUEST FOR ADDITIONAL INFORMATION FOR SECTION 2.2.5, BORAL MONITORING PROGRAM (TAC NO. ME1832)


==Dear Mr. Joyce:==
==Dear Mr. Joyce:==


By letter dated August 18, 2009, as supplemented by letter dated January 23, 2009, Public Service Enterprise Group Nuclear, LLC, submitted an application pursuant to Title 10 of the Code of Federal Regulation Part 54 for renewal of Operating License No. NPF-57 for the Hope Creek Generating Station. The staff of the U.S. Nuclear Regulatory Commission (NRC or the staff) is reviewing this application in accordance with the guidance in NUREG-1800, "Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants.During its review, the staff has identified areas where additional information is needed to complete the review. The staff's requests for additional information are included in the Enclosure. Further requests for additional information may be issued in the future.
By letter dated August 18, 2009, as supplemented by letter dated January 23, 2009, Public Service Enterprise Group Nuclear, LLC, submitted an application pursuant to Title 10 of the Code of Federal Regulation Part 54 for renewal of Operating License No. NPF-57 for the Hope Creek Generating Station. The staff of the U.S. Nuclear Regulatory Commission (NRC or the staff) is reviewing this application in accordance with the guidance in NUREG-1800, Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants. During its review, the staff has identified areas where additional information is needed to complete the review. The staffs requests for additional information are included in the Enclosure. Further requests for additional information may be issued in the future.
Items in the enclosure were discussed with John Hufnagel and other members of your staff during a telephone call on April 7, 2010, and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me by telephone at 301-415-3191 or by e-mail at donnie.ashley@nrc.gov. Sincerely,           /RA/         Donnie J. Ashley, Sr. Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-354  
Items in the enclosure were discussed with John Hufnagel and other members of your staff during a telephone call on April 7, 2010, and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me by telephone at 301-415-3191 or by e-mail at donnie.ashley@nrc.gov.
Sincerely,
                                                /RA/
Donnie J. Ashley, Sr. Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-354


==Enclosure:==
==Enclosure:==


As stated cc w/encl: See next page
As stated cc w/encl: See next page


ML100970350 OFFICE LA:DLR PM:DLR:RPB1 BC:DLR:RPB1 PM:DLR:RPB1 NAME S. Figueroa D. Ashley B. Pham D. Ashley DATE 04/12/10 04/12/10 04/14/10 04/14/10 Letter to T. Joyce from D. Ashley dated April 14, 2010  
ML100970350 OFFICE     LA:DLR           PM:DLR:RPB1       BC:DLR:RPB1       PM:DLR:RPB1 NAME       S. Figueroa       D. Ashley         B. Pham           D. Ashley DATE       04/12/10         04/12/10         04/14/10         04/14/10
 
Letter to T. Joyce from D. Ashley dated April 14, 2010


==SUBJECT:==
==SUBJECT:==
HOPE CREEK GENERATING STATION, LICENSE RENEWAL APPLICATION - REQUEST FOR ADDITIONAL INFORMATION FOR SECTION 2.2.5, BORAL MONITORING PROGRAM (TAC NO. ME1832)
HOPE CREEK GENERATING STATION, LICENSE RENEWAL APPLICATION -
DISTRIBUTION
REQUEST FOR ADDITIONAL INFORMATION FOR SECTION 2.2.5, BORAL MONITORING PROGRAM (TAC NO. ME1832)
:
DISTRIBUTION:
HARD COPY: DLR RF E-MAIL: PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RdsNrrDlrRarb Resource RidsNrrDlrRasb Resource RidsNrrDlrRapb Resource RidsOgcMailCenter Resource ------------- BPham DAshley CEccleston REnnis CSanders MModes, RI DKern, RI JBrand, RI RConte, RI RBellamy, RI MMcLaughlin, RI Hope Creek Generating Station cc:  Mr. Robert Braun Senior Vice President Nuclear PSEG Nuclear LLC One Alloway Creek Neck Road Hancocks Bridge, NJ  08038 Mr. Brian Booth Director Nuclear Oversight PSEG Nuclear P.O. Box 236 Hancocks Bridge, NJ  08038 Mr. John Perry Station Vice President - Hope Creek PSEG Nuclear  P.O. Box 236 Hancocks Bridge, NJ  08038 Mr. Larry Wagner Plant Manager - Hope Creek PSEG Nuclear LLC One Alloway Creek Neck Road Hancocks Bridge, NJ  08038 
HARD COPY:
 
DLR RF E-MAIL:
Mr. Michael Gallagher  Vice President - License Renewal Projects Exelon Nuclear LLC 200 Exelon Way Kennett Square, PA  19348
PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RdsNrrDlrRarb Resource RidsNrrDlrRasb Resource RidsNrrDlrRapb Resource RidsOgcMailCenter Resource
 
-------------
Mr. Jeffrie J. Keenan, Esquire Manager - Licensing PSEG Nuclear LLC One Alloway Creek Neck Road Hancocks Bridge, NJ  08038 Mr. Greg Sosson Director Corporate Engineering PSEG Nuclear LLC One Alloway Creek Neck Road Hancocks Bridge, NJ  08038Mr. Michael Gaffney Manager - Hope Creek Regulatory Assurance PSEG Nuclear LLC One Alloway Creek Neck Road Hancocks Bridge, NJ  08038
BPham DAshley CEccleston REnnis CSanders MModes, RI DKern, RI JBrand, RI RConte, RI RBellamy, RI MMcLaughlin, RI
 
Mr. Ali Fakhar Manager, License Renewal PSEG Nuclear LLC One Alloway Creek Neck Road Hancocks Bridge, NJ  08038 Township Clerk Lower Alloways Creek Township Municipal Building, P.O. Box 157 Hancocks Bridge, NJ  08038 Mr. Paul Bauldauf, P.E., Asst. Director Radiation Protection Programs NJ Department of Environmental  Protection and Energy, CN 415 Trenton, NJ  08625-0415
 
Mr. Brian Beam Board of Public Utilities 2 Gateway Center, Tenth Floor Newark, NJ  07102
 
Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA  19406
 
Mr. Paul Davison Vice President, Operations Support  PSEG Nuclear LLC One Alloway Creek Neck Road Hancocks Bridge, NJ  08038
 
Hope Creek Generating Station cc:  Ms. Christine Neely Director - Regulator Affairs PSEG Nuclear LLC One Alloway Creek Neck Road Hancocks Bridge, NJ  08038 Senior Resident Inspector Hope Creek Generating Station U.S. Nuclear Regulatory Commission Drawer 0509 Hancocks Bridge, NJ  08038 Mr. Earl R. Gage Salem County Administrator Administration Building 94 Market Street Salem, NJ  08079 
 
ENCLOSURE HOPE CREEK GENERATING STATION LICENSE RENEWAL APPLICATION REQUEST FOR ADDITIONAL INFORMATION FOR SECTION 2.2.5, BORAL MONITORING PROGRAM (TAC NO. ME1832)


The Boral Monitoring Program is described in Appendix B as an existing program that is consistent without exception or enhancement to the 10 elements of an Aging Managing Program (AMP), as shown in The Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants NUREG-1800, Revision 1.  
Hope Creek Generating Station cc:
Mr. Robert Braun                          Mr. Michael Gaffney Senior Vice President Nuclear            Manager - Hope Creek Regulatory PSEG Nuclear LLC                          Assurance One Alloway Creek Neck Road              PSEG Nuclear LLC Hancocks Bridge, NJ 08038                One Alloway Creek Neck Road Hancocks Bridge, NJ 08038 Mr. Brian Booth Director Nuclear Oversight                Mr. Ali Fakhar PSEG Nuclear                              Manager, License Renewal P.O. Box 236                              PSEG Nuclear LLC Hancocks Bridge, NJ 08038                One Alloway Creek Neck Road Hancocks Bridge, NJ 08038 Mr. John Perry Station Vice President - Hope Creek      Township Clerk PSEG Nuclear                              Lower Alloways Creek Township P.O. Box 236                              Municipal Building, P.O. Box 157 Hancocks Bridge, NJ 08038                Hancocks Bridge, NJ 08038 Mr. Larry Wagner                          Mr. Paul Bauldauf, P.E., Asst. Director Plant Manager - Hope Creek                Radiation Protection Programs PSEG Nuclear LLC                          NJ Department of Environmental One Alloway Creek Neck Road                Protection and Energy, CN 415 Hancocks Bridge, NJ 08038                Trenton, NJ 08625-0415 Mr. Michael Gallagher                    Mr. Brian Beam Vice President - License Renewal Projects Board of Public Utilities Exelon Nuclear LLC                        2 Gateway Center, Tenth Floor 200 Exelon Way                            Newark, NJ 07102 Kennett Square, PA 19348 Regional Administrator, Region I Mr. Jeffrie J. Keenan, Esquire            U.S. Nuclear Regulatory Commission Manager - Licensing                      475 Allendale Road PSEG Nuclear LLC                          King of Prussia, PA 19406 One Alloway Creek Neck Road Hancocks Bridge, NJ 08038                Mr. Paul Davison Vice President, Operations Support Mr. Greg Sosson                          PSEG Nuclear LLC Director Corporate Engineering            One Alloway Creek Neck Road PSEG Nuclear LLC                          Hancocks Bridge, NJ 08038 One Alloway Creek Neck Road Hancocks Bridge, NJ 08038


RAI 2.2.5-1
Hope Creek Generating Station      cc:
Ms. Christine Neely Director - Regulator Affairs PSEG Nuclear LLC One Alloway Creek Neck Road Hancocks Bridge, NJ 08038 Senior Resident Inspector Hope Creek Generating Station U.S. Nuclear Regulatory Commission Drawer 0509 Hancocks Bridge, NJ 08038 Mr. Earl R. Gage Salem County Administrator Administration Building 94 Market Street Salem, NJ 08079


Element 2 (Preventive Actions), Element 4 (Detection of Aging Effects), and Element 5 (Monitoring and Trending) of the Boral Monitoring Program contain the sentence, "The assumption is that the spent fuel pool environments, including the pool's water chemistry and radiation field, and the Boral material characteristics are consistent enough so that the results at other BWR [boiling water reactor] sites are representative of the results if the Hope Creek Boral test coupons were inspected and/or tested."
HOPE CREEK GENERATING STATION LICENSE RENEWAL APPLICATION REQUEST FOR ADDITIONAL INFORMATION FOR SECTION 2.2.5, BORAL MONITORING PROGRAM (TAC NO. ME1832)
The Boral Monitoring Program is described in Appendix B as an existing program that is consistent without exception or enhancement to the 10 elements of an Aging Managing Program (AMP), as shown in The Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants NUREG-1800, Revision 1.
RAI 2.2.5-1 Element 2 (Preventive Actions), Element 4 (Detection of Aging Effects), and Element 5 (Monitoring and Trending) of the Boral Monitoring Program contain the sentence, The assumption is that the spent fuel pool environments, including the pools water chemistry and radiation field, and the Boral material characteristics are consistent enough so that the results at other BWR [boiling water reactor] sites are representative of the results if the Hope Creek Boral test coupons were inspected and/or tested.
The position that spent fuel pool environments between different BWR plants can be considered to come from a single population has not been supported by the staff. The draft Interim Staff Guidance of November 2009 (LR-ISG-2009-01), cited specific examples of industry operating experience that have shown extrapolations on plant-specific data that were incorrect in trying to determine the future condition of neutron absorbing material in spent fuel pools. The staff clarified that an applicant should consider both plant-specific and industry operating experience in a license renewal application (LRA), and that the plant-specific operating experience should include data from an on-going inspection and monitoring program.
The position that spent fuel pool environments between different BWR plants can be considered to come from a single population has not been supported by the staff. The draft Interim Staff Guidance of November 2009 (LR-ISG-2009-01), cited specific examples of industry operating experience that have shown extrapolations on plant-specific data that were incorrect in trying to determine the future condition of neutron absorbing material in spent fuel pools. The staff clarified that an applicant should consider both plant-specific and industry operating experience in a license renewal application (LRA), and that the plant-specific operating experience should include data from an on-going inspection and monitoring program.
Please discuss your plan to implement changes to your Boral Monitoring Program that will include regular inspections of the spent fuel pool test coupons at Hope Creek Unit 1.
Please discuss your plan to implement changes to your Boral Monitoring Program that will include regular inspections of the spent fuel pool test coupons at Hope Creek Unit 1.
RAI 2.2.5-2 Element 6 (Acceptance Criteria) contains the following sentences:
RAI 2.2.5-2 Element 6 (Acceptance Criteria) contains the following sentences:
If the test report conclusion indicates at least one of the two acceptance criteria is unsatisfactory, the test report information will be entered into the Hope Creek corrective action program for further evaluation. Additionally, this could trigger the requirement to retrieve one Boral test coupon from the Hope Creek spent fuel pool and initiate inspection, testing and evaluation in accordance with the Boral Monitoring Program.
If the test report conclusion indicates at least one of the two acceptance criteria is unsatisfactory, the test report information will be entered into the Hope Creek corrective action program for further evaluation. Additionally, this could trigger the requirement to retrieve one Boral test coupon from the Hope Creek spent fuel pool and initiate inspection, testing and evaluation in accordance with the Boral Monitoring Program.
Please describe the test results that would require a spent fuel pool test coupon to be retrieved, inspected, tested, and evaluated.     RAI 2.2.5-3
Please describe the test results that would require a spent fuel pool test coupon to be retrieved, inspected, tested, and evaluated.
ENCLOSURE


Please discuss the following regarding the spent fuel pool racks:  
RAI 2.2.5-3 Please discuss the following regarding the spent fuel pool racks:
: a. If and how the racks are vented. b. What constitutes a drag test. c. The basis for the conclusion that the 15 cells marked as "DO NOT USE" did not suffer from Boral deformation.}}
: a. If and how the racks are vented.
: b. What constitutes a drag test.
: c. The basis for the conclusion that the 15 cells marked as DO NOT USE did not suffer from Boral deformation.}}

Latest revision as of 21:04, 13 November 2019

License Renewal Application - Request for Additional Information for Section 2.2.5, Boral Monitoring Program
ML100970350
Person / Time
Site: Hope Creek PSEG icon.png
Issue date: 04/14/2010
From: Ashley D
License Renewal Projects Branch 1
To: Joyce T
Public Service Enterprise Group
Ashley D
References
TAC ME1832
Download: ML100970350 (7)


Text

April 14, 2010 Mr. Thomas Joyce President and Chief Nuclear Officer PSEG Nuclear LLC P.O. Box 236 Hancocks Bridge, NJ 08038

SUBJECT:

HOPE CREEK GENERATING STATION, LICENSE RENEWAL APPLICATION -

REQUEST FOR ADDITIONAL INFORMATION FOR SECTION 2.2.5, BORAL MONITORING PROGRAM (TAC NO. ME1832)

Dear Mr. Joyce:

By letter dated August 18, 2009, as supplemented by letter dated January 23, 2009, Public Service Enterprise Group Nuclear, LLC, submitted an application pursuant to Title 10 of the Code of Federal Regulation Part 54 for renewal of Operating License No. NPF-57 for the Hope Creek Generating Station. The staff of the U.S. Nuclear Regulatory Commission (NRC or the staff) is reviewing this application in accordance with the guidance in NUREG-1800, Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants. During its review, the staff has identified areas where additional information is needed to complete the review. The staffs requests for additional information are included in the Enclosure. Further requests for additional information may be issued in the future.

Items in the enclosure were discussed with John Hufnagel and other members of your staff during a telephone call on April 7, 2010, and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me by telephone at 301-415-3191 or by e-mail at donnie.ashley@nrc.gov.

Sincerely,

/RA/

Donnie J. Ashley, Sr. Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-354

Enclosure:

As stated cc w/encl: See next page

ML100970350 OFFICE LA:DLR PM:DLR:RPB1 BC:DLR:RPB1 PM:DLR:RPB1 NAME S. Figueroa D. Ashley B. Pham D. Ashley DATE 04/12/10 04/12/10 04/14/10 04/14/10

Letter to T. Joyce from D. Ashley dated April 14, 2010

SUBJECT:

HOPE CREEK GENERATING STATION, LICENSE RENEWAL APPLICATION -

REQUEST FOR ADDITIONAL INFORMATION FOR SECTION 2.2.5, BORAL MONITORING PROGRAM (TAC NO. ME1832)

DISTRIBUTION:

HARD COPY:

DLR RF E-MAIL:

PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RdsNrrDlrRarb Resource RidsNrrDlrRasb Resource RidsNrrDlrRapb Resource RidsOgcMailCenter Resource


BPham DAshley CEccleston REnnis CSanders MModes, RI DKern, RI JBrand, RI RConte, RI RBellamy, RI MMcLaughlin, RI

Hope Creek Generating Station cc:

Mr. Robert Braun Mr. Michael Gaffney Senior Vice President Nuclear Manager - Hope Creek Regulatory PSEG Nuclear LLC Assurance One Alloway Creek Neck Road PSEG Nuclear LLC Hancocks Bridge, NJ 08038 One Alloway Creek Neck Road Hancocks Bridge, NJ 08038 Mr. Brian Booth Director Nuclear Oversight Mr. Ali Fakhar PSEG Nuclear Manager, License Renewal P.O. Box 236 PSEG Nuclear LLC Hancocks Bridge, NJ 08038 One Alloway Creek Neck Road Hancocks Bridge, NJ 08038 Mr. John Perry Station Vice President - Hope Creek Township Clerk PSEG Nuclear Lower Alloways Creek Township P.O. Box 236 Municipal Building, P.O. Box 157 Hancocks Bridge, NJ 08038 Hancocks Bridge, NJ 08038 Mr. Larry Wagner Mr. Paul Bauldauf, P.E., Asst. Director Plant Manager - Hope Creek Radiation Protection Programs PSEG Nuclear LLC NJ Department of Environmental One Alloway Creek Neck Road Protection and Energy, CN 415 Hancocks Bridge, NJ 08038 Trenton, NJ 08625-0415 Mr. Michael Gallagher Mr. Brian Beam Vice President - License Renewal Projects Board of Public Utilities Exelon Nuclear LLC 2 Gateway Center, Tenth Floor 200 Exelon Way Newark, NJ 07102 Kennett Square, PA 19348 Regional Administrator, Region I Mr. Jeffrie J. Keenan, Esquire U.S. Nuclear Regulatory Commission Manager - Licensing 475 Allendale Road PSEG Nuclear LLC King of Prussia, PA 19406 One Alloway Creek Neck Road Hancocks Bridge, NJ 08038 Mr. Paul Davison Vice President, Operations Support Mr. Greg Sosson PSEG Nuclear LLC Director Corporate Engineering One Alloway Creek Neck Road PSEG Nuclear LLC Hancocks Bridge, NJ 08038 One Alloway Creek Neck Road Hancocks Bridge, NJ 08038

Hope Creek Generating Station cc:

Ms. Christine Neely Director - Regulator Affairs PSEG Nuclear LLC One Alloway Creek Neck Road Hancocks Bridge, NJ 08038 Senior Resident Inspector Hope Creek Generating Station U.S. Nuclear Regulatory Commission Drawer 0509 Hancocks Bridge, NJ 08038 Mr. Earl R. Gage Salem County Administrator Administration Building 94 Market Street Salem, NJ 08079

HOPE CREEK GENERATING STATION LICENSE RENEWAL APPLICATION REQUEST FOR ADDITIONAL INFORMATION FOR SECTION 2.2.5, BORAL MONITORING PROGRAM (TAC NO. ME1832)

The Boral Monitoring Program is described in Appendix B as an existing program that is consistent without exception or enhancement to the 10 elements of an Aging Managing Program (AMP), as shown in The Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants NUREG-1800, Revision 1.

RAI 2.2.5-1 Element 2 (Preventive Actions), Element 4 (Detection of Aging Effects), and Element 5 (Monitoring and Trending) of the Boral Monitoring Program contain the sentence, The assumption is that the spent fuel pool environments, including the pools water chemistry and radiation field, and the Boral material characteristics are consistent enough so that the results at other BWR [boiling water reactor] sites are representative of the results if the Hope Creek Boral test coupons were inspected and/or tested.

The position that spent fuel pool environments between different BWR plants can be considered to come from a single population has not been supported by the staff. The draft Interim Staff Guidance of November 2009 (LR-ISG-2009-01), cited specific examples of industry operating experience that have shown extrapolations on plant-specific data that were incorrect in trying to determine the future condition of neutron absorbing material in spent fuel pools. The staff clarified that an applicant should consider both plant-specific and industry operating experience in a license renewal application (LRA), and that the plant-specific operating experience should include data from an on-going inspection and monitoring program.

Please discuss your plan to implement changes to your Boral Monitoring Program that will include regular inspections of the spent fuel pool test coupons at Hope Creek Unit 1.

RAI 2.2.5-2 Element 6 (Acceptance Criteria) contains the following sentences:

If the test report conclusion indicates at least one of the two acceptance criteria is unsatisfactory, the test report information will be entered into the Hope Creek corrective action program for further evaluation. Additionally, this could trigger the requirement to retrieve one Boral test coupon from the Hope Creek spent fuel pool and initiate inspection, testing and evaluation in accordance with the Boral Monitoring Program.

Please describe the test results that would require a spent fuel pool test coupon to be retrieved, inspected, tested, and evaluated.

ENCLOSURE

RAI 2.2.5-3 Please discuss the following regarding the spent fuel pool racks:

a. If and how the racks are vented.
b. What constitutes a drag test.
c. The basis for the conclusion that the 15 cells marked as DO NOT USE did not suffer from Boral deformation.