ML17348A628

From kanterella
Jump to navigation Jump to search
NRR E-mail Capture - Draft Request for Additional Information for Steam Dryer Analysis with the Hope Creek Measurement Uncertainty Recapture Uprate Request (L-2017-LLS-002)
ML17348A628
Person / Time
Site: Hope Creek 
Issue date: 11/21/2017
From: Lisa Regner
Plant Licensing Branch IV
To: Duke P
Public Service Enterprise Group
References
L-2017-LLS-002, MF9930
Download: ML17348A628 (3)


Text

1 NRR-DMPSPEm Resource From:

Regner, Lisa Sent:

Tuesday, November 21, 2017 4:05 PM To:

Paul.Duke@pseg.com; Thomas, Brian J.

Cc:

Regner, Lisa

Subject:

DRAFT Request for Additional Information - Steam Dryer Analysis Paul, Brian, Please see the request below. The NRC staff needs the information in the steam dryer analysis to complete its SE and make its safety determination. Please let me know if you have questions.

Lisa REQUEST FOR ADDITIONAL INFORMATION LICENSE AMENDMENT REQUEST FOR MEASUREMENT UNCERTAINTY RECAPTURE (MUR) POWER UPRATE PSEG NUCLEAR LLC (PSEG)

HOPE CREEK GENERATING STATION (HOPE CREEK)

DOCKET NO. 50-354 (CAC MF9930; EPID L-2017-LLS-0002)

By letter dated July 07, 2017 (Agencywide Documents Access and Management System Accession No. ML17188A260), PSEG Nuclear LLC (the licensee) submitted a License Amendment request for Hope Creek Generating Station (Hope Creek). The amendment would revise the Renewed Facility Operating Licenses (RFOLs) and Technical Specifications (TSs) to implement a measurement uncertainty recapture (MUR) power uprate. Specifically, the amendments would authorize an increase in the maximum licensed thermal power level from 3,840 megawatts thermal (MWt) to 3,902 MWt, which is an increase of approximately 1.61 percent above the current thermal power, or an increase of 19 percent above the original licensed thermal power (3293 MWt.).

To complete its review, the Nuclear Regulatory Commission (NRC) staff requests the following additional information.

EMIB-01 In enclosure 1 to LAR H17-03, Section 3.4.2 on Adverse Flow Effects, the licensee references steam dryer stress analysis document, but this document was not provided to the NRC. The steam dryer analysis reveals the low margin due to an Acoustic Circuit Model (ACM) code error discovered in 2015. The licensee is requested to provide the document, CDI Technical Note (TN)16-23P, Steam Dryer Analysis on the docket for NRC review and to allow the NRC staff to reach a safety conclusion regarding the continued structural integrity of the steam dryer and verify the margin for high cycle fatigue stresses due to adverse flow effects.

Lisa Regner Sr. Project Manager NRR/DORL/LPL4 301-415-1906 O9D14

2

Hearing Identifier:

NRR_DMPS Email Number:

52 Mail Envelope Properties (Lisa.Regner@nrc.gov20171121160500)

Subject:

DRAFT Request for Additional Information - Steam Dryer Analysis Sent Date:

11/21/2017 4:05:08 PM Received Date:

11/21/2017 4:05:00 PM From:

Regner, Lisa Created By:

Lisa.Regner@nrc.gov Recipients:

"Regner, Lisa" <Lisa.Regner@nrc.gov>

Tracking Status: None "Paul.Duke@pseg.com" <Paul.Duke@pseg.com>

Tracking Status: None "Thomas, Brian J." <Brian.Thomas@pseg.com>

Tracking Status: None Post Office:

Files Size Date & Time MESSAGE 2046 11/21/2017 4:05:00 PM Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received: