Line 1: |
Line 1: |
| #REDIRECT [[IR 05000269/1986005]]
| | {{Adams |
| | | number = ML20199G445 |
| | | issue date = 03/25/1986 |
| | | title = Insp Repts 50-269/86-05,50-270/86-05 & 50-287/86-05 on 860224-28.Violation Noted:Failure to Provide Adequate Respiratory Protective Equipment to Maintain Intakes of Radioactive Matl ALARA |
| | | author name = Collins T, Hosey C |
| | | author affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| | | addressee name = |
| | | addressee affiliation = |
| | | docket = 05000269, 05000270, 05000287 |
| | | license number = |
| | | contact person = |
| | | document report number = 50-269-86-05, 50-269-86-5, 50-270-86-05, 50-270-86-5, 50-287-86-05, 50-287-86-5, NUDOCS 8604090139 |
| | | package number = ML20199G398 |
| | | document type = INSPECTION REPORT, NRC-GENERATED, INSPECTION REPORT, UTILITY, TEXT-INSPECTION & AUDIT & I&E CIRCULARS |
| | | page count = 9 |
| | }} |
| | See also: [[see also::IR 05000269/1986005]] |
| | |
| | =Text= |
| | {{#Wiki_filter:_ . _ . . . |
| | , |
| | * |
| | , $ narco URITED STATES |
| | - |
| | o NUCLEAR REGULATORY COMMISSION |
| | " |
| | , REGloN 11 |
| | [' n |
| | g j 101 MARIETTA STRE ET.N.W. |
| | * 'c ATLANTA, GEORGI A 30323 |
| | %, |
| | ***** |
| | / ' |
| | . |
| | fM 2 7 T.i36 |
| | Report Nos.: 50-269/86-05, 50-270/86-05 and 50-287/86-05 |
| | Licensee: Duke Power Company |
| | 422 South Church Street |
| | Charlotte,.NC 28242 |
| | Docket Nos.: 50-269, 50-270, and 50-287 License Nos.: DPR-38, DPR-47, and |
| | DPR-55 |
| | Facility Name: Oconee |
| | Inspection Conducted: February 24-28, 1986 |
| | Inspector : |
| | T. R. Colli s |
| | M8 |
| | _[ Tate S'igned |
| | Approved by: |
| | C. M. Hosdy, Sect ~ on Chief |
| | J/27h// |
| | Dats S;gn'ed |
| | Emergency Prepardtess and Radiological |
| | Protection Branch |
| | Division of Radiation Safety and Safeguards |
| | SUMMARY |
| | Scope: This routine, unannounced inspection involved 36 inspector-hours on site |
| | during normal hours, inspecting the radiation protection program including |
| | training and qualification of personnel, internal and external exposure control, |
| | radioactive material control, posting and labeling, and the program for |
| | maintaining exposure as low as reasonably achievable (ALARA). |
| | Results: One violation was identified in the area of failure to provide adequate |
| | respiratory protective equipment to maintain intakes of radioactive material as |
| | low as reasonably achievable. |
| | I |
| | O |
| | _. . |
| | |
| | g - |
| | p( |
| | , |
| | e |
| | . . |
| | p - |
| | 2 |
| | . REPORT DETAILS |
| | 1. Persons Contacted |
| | ' Licensee Employees |
| | *M. S. Tuckman, Station Manager |
| | *T. S. Barr, Superintendant of Technical Services |
| | *C. T. Yongue, Station Health Physicist |
| | *E. Brown, Health Physics Supervisor |
| | *M. Thorne, Health Physics Supervisor |
| | *T. C. Matthews. Compliance Technical Specialist |
| | J. Owens, Health Pnysics Supervisor |
| | T. Cherry, ALARA Coordinator |
| | - S. Spears, Health Physics Coordinator |
| | C. Harlin, Health Physics Coordinator |
| | L. Garrett, ETQS Coordinator |
| | B. Earnhart, Outage and Planning Coordinator |
| | Other licensee employees contacted included four construction craftsmen, |
| | five. technicians, two operators, three' mechanics, three security force |
| | members, and.two office personnel. |
| | Other Organizations |
| | RAD Services, Inc. |
| | NRC Resident-Inspectors |
| | *J. Bryant, Senior Resident Inspector |
| | *K. Sasser, Resident Inspector |
| | * Attended exit interview |
| | 2. Exit. Interview |
| | The inspection scope and findings were summarized on February 28, 1986, with |
| | those . persons indicated in paragraph 1 above. The inspector discussed the |
| | apparent violation for not providing adequate respiratory protection to |
| | individuals while working in Unit #3 Containment on March 29, 1985. See |
| | report details paragraph 9. |
| | The licensee did not identify as proprietary any of the materials provided |
| | to or reviewed by the inspector during tnis inspection. |
| | 3. Licensee Action on Previous Enforcement Matters |
| | (Closed) Unresolved Item 50-269, 270, and 267/85-42-02. Provide air sample |
| | results to assure adequate evaluation of airborne radioactive material. The |
| | w |
| | , |
| | |
| | . ~. |
| | . . |
| | . |
| | 3 |
| | inspector reviewed air sample results as provided by the licensee and |
| | concluded that the licensee did evaluate and document air sample results to |
| | evaluate the radiation hazards present to assure personnel did not exceed 40 |
| | MPC-hrs. |
| | (Closed) Unresolved Item 50-269, 270 and 287/85-42-03. Provide air sample |
| | data to evaluate airborne radioactivity in Unit #3 Containment. The |
| | inspection reviewed air sample results of Unit #3 Containment as provided by |
| | the licensee and concluded that the licensee had taken an adequate air |
| | sample to evaluate the air concentrations in Unit #3 Containment. |
| | 4. Training and Qualifications (83723) |
| | a. Basic Radiation Protection Training |
| | The licensee was required by 10 CFR 19.12 to provide basic radiation |
| | protection training to workers. Regulatory Guides 8.27, 8.29, and |
| | 8.13, outline topics that should be included in such training. . |
| | Chapters 12 and 13 of the FSAR contain further commitments regarding |
| | training. During tours of the plant, the inspector discussed topics |
| | from the GET training with a maintenance mechanic to determine the |
| | " |
| | effectiveness of the training. The inspector selectively reviewed the |
| | GET training records fcr workers to determine if records reflected |
| | adequate completion of GET initial and refresher training. |
| | b. Radiation Protection and Chemistry Technician Qualification |
| | 'The inspector reviewed the program for qualifiction of contract |
| | radiation protection technicians. The inspector discussed separately |
| | with three contract technicians their previous experience and training |
| | to determine if it was comprehensive or if it had been limited to |
| | selected tasks. The inspector also discussed the training and |
| | qualification program the licensee had provided, what limits had been |
| | placed on their activities, and controls that should be established for |
| | one task they were qualified to perform. The inspector reviewed the |
| | resumes, training records, and tests for these technicians. - |
| | c. Respiratory Protection Training |
| | The licensee was required by 10 CFR 20.103 to establish a qualification |
| | program for workers who wear respiratory protective equipment. |
| | Elements of the qualification program outlined in 10 CFR 20.103 we are |
| | - |
| | delineated in NUREG-0041. The inspector observed workers using |
| | respirators while they were performing maintenance in the auxiliary |
| | building. The inspectors discussed this use with the radiation |
| | protection technician covering the job and with the workers. The |
| | inspector reviewed the workers' respirator qualification reccrds. The |
| | inspector reviewed recent changes in the respirator qualification |
| | program and discussed these changes with the training supervisor. |
| | . |
| | No violations or deviations were identified. |
| | |
| | -- . ___ _. _. _ _ . _ _ _ _ _ _ _ _ _ _ - _ _ _ |
| | e |
| | . ~. |
| | . |
| | 4 |
| | d. Technical Specification 6.1 specified minimum plant staffing. FSAR |
| | Chapters 12 and 13 also outlined further details on staffing. The |
| | inspector discussed authorized staffing levels and actual on-board |
| | - staffing separately with the Station Health Physicist- and Station |
| | Manager. The inspector exarr.ined shift staffing for the midnight shift |
| | on February 25, 1986, to determine if it met minimum criteria fc |
| | radiation protection. |
| | No violations or deviations were identified. |
| | 5. Control of Radioactive Materials and Contamination, Surveys, and Monitoring |
| | (83726) |
| | The licensee was required by 10 CCR 20.201(b) and 20.401 to perform surveys |
| | to show compliance with regulatory limits and to maintain records of such |
| | surveys. Chapter 12 of the FSAR further outlines survey methods and |
| | instrumentation. Technical Specification 6.8 required the licensee to |
| | follow written procedures. Radiological control procedures further outlined |
| | survey methods and frequencies. |
| | a. The inspector observed, during plant tours, surveyt being performed by |
| | radiation protection staff. The inspector reviewed selected radiation |
| | work permits, to determine if adequate controls were specified. The |
| | inspector discussed the controls and monitoring with the radiation |
| | protection technician assigned. |
| | During plant tours, the inspector observed radiation level and |
| | contamination survey results outside selected cubicles. The inspector |
| | performed independent radiation surveys of selected areas and compared |
| | them to licensee survey results. The inspector reviewed selected |
| | survey records for the month of February 1986 and discussed with |
| | licensee representatives methods used to disseminate st.rvey results. |
| | The inspector noted that there were several locked high radiation areas |
| | outside containment, |
| | b. Frisking |
| | During tours of the plant, the inspector observed the exit of workers |
| | and movement of material from contamination control areas to clean |
| | ~ |
| | areas to determine if proper frisking was performed by workers and that |
| | proper direct and removable contamination surveys were performed on |
| | materials. The inspector reviewed records of skin contamination |
| | occurrences and resulting evaluations and corrective actions. Records |
| | and discussions with licensee representatives showed contamination had |
| | been promptly removed from the workers using routine washing |
| | techniques. Subsequent whole body counts showed less than detectable |
| | internal deposition of radioactive material. |
| | |
| | -- - |
| | 7 _ |
| | c . |
| | . |
| | 5 |
| | c. Instrumentation |
| | During plant tours, the inspector observed the use of survey instru- |
| | ments by plant staff and compared plant survey meter results with |
| | results .of surveys made by the inspector using NRC equipment. The |
| | inspector examined calibration stickers on radiation protection |
| | instruments in use by licensee staff and stored in the radiation |
| | protection laboratory. The inspector discussed with radiation |
| | protection technicians the methods for doing instrument source checks |
| | prior to each use and calibration methods. The inspector reviewed the |
| | procedures and methods for calibration of survey instruments and |
| | friskers. |
| | d. Release of Materials for Unrertricted Use |
| | The inspector discussed, with a radiation protection technician, the |
| | program _ for survey-out of items from contaminated areas and reviewed |
| | the procedures for such release. The inspector observed release |
| | surveys performed by radiation protection technicians, and documen- |
| | tation of results. The inspector performed confirmatory direct and |
| | removable contamination surveys on items released. During tours of |
| | plant areas, the inspector observed posting of containers and performed |
| | indepencent surveys to determine if containers of radioactive material |
| | were properly' identified. |
| | No violations or deviations were identift.ed. |
| | 6. Facilities and Equipment (83727) |
| | FSAR Chapters 1 and 12 specified plant i yout and radiation protection |
| | facilities and equipment. During plant tours, the inspector observed the |
| | operation of the contaminated clothing laundry, the flow of traffic thru |
| | change rooms, the use of temporary shielding and the use of glove bags, and |
| | ventilated containment enclosures. |
| | No violations or deviations were identified. |
| | 7. External Occupational Dose Control and Personal Dosimetry (83724) |
| | During plant tours, the inspector checked the security of the locks at |
| | several locked high radiatior, areas and observed posting of survey results |
| | , |
| | and the use of controls specified on six radiation work permits (RWPs), |
| | a. Use of Dosimeters and Controls . |
| | The licensee was required by 10 CFR 20.202, 20.201(b), 20.102, 20.102, |
| | 20.104, 20.402, 20.403, 20.405, 19.13, 20.407, 20.408 to maintain |
| | workers's doses below specified levels and keep records of and make |
| | reports of doses. The licensee was required by 10 CFR 20.203 to post |
| | and control access to plant areas. FSAR Chapter 12 also contained |
| | commitments regarding dosimetry and dose controls. During observation |
| | |
| | n |
| | . *s |
| | . |
| | 6 |
| | of work in the plant, the inspector observed the wearing of TLDs and |
| | pocket dosimeters by workers. The inspector discussed the assignment |
| | ~ |
| | and use of- dosimeters with maintenance mechanics and radiation |
| | protection technicians. During plant tours, the inspector observed the |
| | -posting of areas and made independent measurements of dose to assure |
| | proper posting. The inspector reviewed recent changes to plant pro- |
| | cedures regarding the use of TLDs and dosimeters. |
| | b. Processing of Dosimeters |
| | The inspector discussed with the Dosimetry Supervisor the flow of the |
| | TLD badge from its return by a worker thru the recording of information |
| | (dose) from the readout on the worker's dose record, to determine areas |
| | where information could r,ssibly be mishandled. The inspector |
| | discussed, with an assigned radiation protection technician, the system |
| | for comparison of TLD and pocket dosimeter results. The inspector |
| | reviewed the records of pocket dosimeter drift and calibration checks |
| | for the year of 1935. |
| | c. Dosimetry Results |
| | The inspector reviewed the TLD results for 1985 and for the first |
| | quarter of 1986. The inspector selectively examined individuals' |
| | . |
| | dosimetry files to determine if NRC Form 4's had been completed. The |
| | inspector selectively reviewed the results of the TLD vs. pocket |
| | chamber comparisons for the year of 1985. |
| | d. Management Review of Dosimetry Results |
| | The inspector discussed the dosimetry results with a Health Physic's |
| | Supervisor, concentratirg on their assigned staff to determine their |
| | ' |
| | understanding of dosimetry results for their staff. The inspector |
| | reviewed records of administrative doso control extensions for the year |
| | 1985 and discussed the extensions with selected supervisors and staff. |
| | The inspector reviewed records of cases where workers exceeded |
| | administrative controls without dose extensions. The inspector |
| | discussed these cases with selected involved individuals and reviewed |
| | corrective actions. |
| | No violations or deviations were identified. |
| | 9. Internal Exposure Control and Assessment (83725) |
| | The licensee was required by 10 CFR 20.103, 20,201(b), 20.401, 20.403, and |
| | 20.405 to control uptakes of radioactive material, assess such uptakes, and |
| | keep records of and make reports of such uptakes. FSAR Chapter 12 also |
| | includes commitments regarding internal exposure control and assessment. |
| | |
| | ,- |
| | ' |
| | p . A |
| | . |
| | 7 |
| | a. Control Measures |
| | During plant tours, the inspector observed the use of temporary |
| | ventilation systems, containment enclosures, and respirators. The |
| | -inspector discussed the use of this equipment with workers and radia- |
| | " |
| | tion protection technicians. |
| | b. Respiratory Maintenance and Issue |
| | The inspector observed the issuance of respirators and reviewed records |
| | for several workers who were issued respirators to determine if they |
| | were qualified for the respirators issued. The inspector reviewed |
| | recent changes to respirator maintenance and issue procedures, |
| | c. Respirator Fit Testing and Training |
| | The inspector discussed fit testing with Health Physics personnel. The |
| | inspector reviewed recent changes to procedures regarding fit testing |
| | and training. The inspector discussed respiratory protection training |
| | with workers, |
| | d. Uptake Assessment |
| | The inspector observed operation of whole body counter and discussed |
| | its operation and results with the counter operator. The inspector |
| | reviewed the results of the analyses performed for selected individuals |
| | for 1985. The inspector discussed the assessments and corrective |
| | actions with Health Physics personnel. The inspector reviewed the |
| | Maximum Permissible Concentration-hour (MPC-hour) log for selected |
| | periods of 1985 and discussed the actions taken by the licensee for |
| | personnel that received greater than 2 MPC-hours in a day and 10 |
| | MPC-hours in a week. |
| | The inspector reviewed the MPC hour logs for 1985 and noted there were |
| | no personnel listed with greate. than 40 MPC-hours during a week. |
| | However, the inspector noted an event which occurred on March 29, 1985, |
| | where workers were allowed to enter Unit #3 Containment to perform |
| | associated duties during reactor start-up. During this period high |
| | concentrations of Iodine-131 were present, up to approximately 20 times |
| | the Maximum Permissible Concentrations (MPCs) set forth in 10 CFR 20 |
| | Appendix B. The licensee permitted these personnel to enter |
| | containment without adequate respiratory equipment which resulted in |
| | the individuals receiving uptakes of radioactive material ranging from |
| | 1.5% maximum permissible organ burden (MPOB) to 6.5% MPB0 Iodine-131. |
| | 10 CFR 20.103(b)(2) requires in part that respiratory protective |
| | equipment be used to limit the intake of radioactive material to as low |
| | as is reasonably achievable. The licensee stated that they decided not |
| | to provide respirators equipped with iodine removal canisters to these |
| | l personnel because the shelf life on the canisters had expired and that |
| | ; they felt the job could be performed faster and safer without |
| | |
| | .. . - _ . _ _ . - |
| | .. |
| | _ |
| | , |
| | . . |
| | , |
| | k |
| | 8 |
| | - |
| | - |
| | respiratory equipment. Failure to maintain intakes of radioactive |
| | - |
| | material as low as is reasonably achievable was identified as an |
| | apparent violation of 10 CFR 20.103(b)(2) (50-269,270, and |
| | 287/86-05-01). |
| | 10. Maintaining Occupational Doses ALARA (83726) |
| | { |
| | 10 CFR 20.1(c) specifies that licensees should implement programs to keep |
| | ; workers' doses ALARA. FSAR Chapter 12 also contains licensee commitmentt |
| | regarding worker ALARA actions. |
| | _ |
| | a. Worker and Supervisor Actions |
| | The inspector discussed with ALARA personnel their actions to reduce |
| | individual and collective doses, concentrating particularly on staff |
| | ' |
| | members with highest doses. The inspector also discussed these actions |
| | to set dose goals for tasks, methods used to reduce dqses, and |
| | techniques used to monitor performance against goals. |
| | -- |
| | . b. ALARA Procedure Changes |
| | : |
| | The inspector reviewed recent changes to administrative procedures that |
| | L implemented the elements of ALARA. The inspector discussed these |
| | enanges with the ALARA' Coordinator. |
| | c |
| | c. ALARA Reviews |
| | : The inspector reviewed the ALARA review documentation for selected |
| | : |
| | " |
| | activities during 1985 and discussed resulting actions with the ALARA |
| | _ |
| | Coordinator. |
| | -- |
| | d. ALARA Reports |
| | The inspector reviewed selected ALARA Reports for 1985 and the 1985 |
| | - |
| | _ |
| | ALARA summary report and discussed the results with the ALARA Coordi- |
| | natory and Station Health Physicist. The summary of tasks estimate for |
| | 1985 was 1093 man-rems. The total cumulative dose for 1985 was 1303 |
| | man-rems. The outage estimate for 1986 was 395 man-rems. Through |
| | February 24, 1986, the total was 176 man-rem. |
| | No violations or deviations were identi'~ed. |
| | _ |
| | 11. Problem Reports and Radiological Deficier :y Reports. |
| | - |
| | The inspector selectively examined the Problem Reports and Radiological |
| | _ |
| | Deficiency Reports and resulting corrective actions for the period January |
| | - |
| | - |
| | through June 1985. |
| | No violations or deviations were identified. |
| | K |
| | _ |
| | E |
| | 5 |
| | EL |
| | |
| | r |
| | ;L . |
| | .. . |
| | ~ ~~ ' " ' " ~ |
| | 9 , |
| | l |
| | ;y , |
| | , |
| | '12. Preparation for Mardh 1986 Outage |
| | -a. Work Packages |
| | The inspector discussed the preparations for the February 1985 outage |
| | with the Outage Coordinator, ALARA Coordinator, and the Station Health |
| | Physicist. The inspector reviewed the task list for the outage. |
| | b. Radiation Protection and Chemistry Staffing |
| | -The inspector discussed with the Station Manager and the Statica Health |
| | Physicist, the plans for supplemental staffing, including decon, |
| | shielding, and laundry staff, during the outage and subsequent startup. |
| | The inspector. discussed methods to be. used to select and qualify the |
| | staff with contractor support, proposed metheds of supervision and |
| | limitations on task assignments. |
| | Na violations or deviations were identified. |
| | . |
| | }} |
|
---|
Category:INSPECTION REPORT
MONTHYEARIR 05000269/19930321994-01-0606 January 1994 Insp Repts 50-269/93-32,50-270/93-32,50-287/93-32, 50-369/93-31,50-370/93-31,50-413/93-35 & 50-414,respectively on 931213-17.Violations Noted.Major Areas Inpected:Licensee Safeguards Info Program to folow-up on Licensee Repts IR 05000269/19930061993-03-22022 March 1993 Partially Withheld Insp Repts 50-269/93-06,50-270/93-06 & 50-287/93-06 on 930222-25 (Ref 10CFR73.21).No Violations or Deviations Noted.Major Areas Inspected:Licensee Physical Security Program for Power Reactors IR 05000269/19930011993-02-0101 February 1993 Safeguards Insp Repts 50-269/93-01,50-270/93-01 & 50-287/93-01 on 930104-07.No Violations Noted.Major Areas Inspected:Physical Security Program.Details Withheld (Ref 10CFR73.21) IR 05000269/19920251992-12-0303 December 1992 Insp Repts 50-269/92-25,50-270/92-25 & 50-287/92-25 on 921102-06.No Violations or Deviations Noted.Major Areas Inspected:Physical Security Program for Power Reactors, Audits,Protected & Vital Area Barriers.Details Withheld IR 05000269/19910081991-04-10010 April 1991 Insp Repts 50-269/91-08,50-270/91-08 & 50-287/91-08 on 910312-15.violations Noted.Major Areas Inspected:Maint, Control Room Operation,Planning & Scheduling Activities, Training & Procedures,Plant Physical Condition & Mgmt IR 05000269/19900321990-11-0505 November 1990 Partially Withheld Insp Repts 50-269/90-32,50-270/90-32 & 50-287/90-32 on 901015-19.No Violations Noted.Major Areas Inspected:Physical Security Program Plans,Mgt Support, Security Program Plans & Protected & Vital Area Barriers IR 05000269/19900221990-07-24024 July 1990 Partially Withheld Safeguard Insp Repts 50-269/90-22, 5-270/90-22 & 50-287/90-22 on 900625-29.No Violations or Deviation Noted.Major Areas Inspected:Core Insp Program for Power Reactors & Safeguards Contingency Plan Implementation IR 05000269/19900181990-06-21021 June 1990 Partially Withheld Insp Repts 50-269/90-18,50-270/90-18 & 50-287/90-18 on 900604-08 (Ref 10CFR2.790 & 73.21).No Violations Noted.Major Areas Inspected:Security Program Audit,Detection & Assessment Aids & Key Control IR 05000269/19890201989-07-25025 July 1989 Partially Withheld Insp Repts 50-269/89-20,50-270/89-20 & 50-287/89-20 on 890626-30 (Ref 10CFR2.790.(d) & 73.21). Violations Noted.Major Areas Inspected:Physical Security Program for Power Reactors & Security Audit IR 05000269/19890101989-05-19019 May 1989 Partially Withheld Insp Repts 50-269/89-10,50-270/89-10 & 50-287/89-10 on 890410-14 (Ref 10CFR2.790 & 73.21). Violations Noted.Major Areas Inspected:Mgt Support,Security Program Plans & Audits & Protected & Vital Area Barriers IR 05000269/19890091989-04-10010 April 1989 Insp Repts 50-269/89-09,50-270/89-09 & 50-287/89-09 on 890306-10.No Violations Noted.Weaknesses Noted Re Data Base Used to Prepare computer-generated Work Requests.Major Areas Inspected:Design Control,Mods & Open Items IR 05000269/19890071989-03-10010 March 1989 Insp Repts 50-269/89-07,50-270/89-07 & 50-287/89-07 on 890213-17.Deviation Noted.Major Areas Inspected:Conformance to Reg Guide 1.97 Re Instrumentation for light-water-cooled Plants to Assess Conditions During & Following Accident IR 05000269/19880051988-03-21021 March 1988 Insp Repts 50-269/88-05,50-270/88-05 & 50-287/88-05 on 880217-0316.No Violations Noted.Major Areas Inspected:Maint, Operations,Surveillance,Physical Security & Design Changes IR 05000269/19870101987-03-17017 March 1987 Insp Repts 50-269/87-10,50-270/87-10 & 50-287/87-10 on 870210-0309.No Violations or Deviations Noted.Major Areas Inspected:Areas of Operations,Surveillance,Maint,Followup of Events & Verification of ESF Lineups IR 05000269/19870091987-03-17017 March 1987 Insp Repts 50-269/87-09,50-270/87-09 & 50-287/87-09 on 870209-13.No Violations Noted.Major Areas Inspected:Onsite Review of Liquid & Gaseous Radwaste Programs & Review of TMI Action Items II.B.3 & II.F.1.2 IR 05000269/19870061987-03-0909 March 1987 Insp Repts 50-269/87-06,50-270/87-06 & 50-287/87-06 on 870126-30.No Violations or Deviations Noted.Major Areas Inspected:Inservice Insp,Ongoing Repairs in Reactor Coolant Pumps & Maint & Welding Activities IR 05000269/19870041987-02-17017 February 1987 Insp Repts 50-269/87-04,50-270/87-04 & 50-287/87-04 on 870113-0209.No Violation or Deviation Noted.Major Areas Inspected:Operations,Surveillance,Maint,Verification of ESF Linups,Followup of Events & Shutdown Work in Progress IR 05000269/19870021987-02-11011 February 1987 Partially Withheld Insp Repts 50-269/87-02,50-270/87-02 & 50-287/87-02 on 870126-30 (Ref 10CFR2.790).Violation Noted Re Inadequate App R Circuit Analysis IR 05000269/19870031987-02-10010 February 1987 Insp Repts 50-269/87-03,50-270/87-03 & 50-287/87-03 on 870112-16.Violation Noted:Failure to Adequately Evaluate Radiological Hazards IR 05000269/19870081987-02-0505 February 1987 Enforcement Conference Repts 50-269/87-08,50-270/87-08 & 50-287/87-08 on 861222.Major Areas Discussed:Safety Sys Functional Insp & Associated Safety Implications IR 05000269/19870071987-02-0505 February 1987 Enforcement Conference Repts 50-269/87-07,50-270/87-07 & 50-287/87-07 on 861222.Major Areas Discussed:Sequence of Events & Corrective Actions Re Emergency Condenser Circulating Water Sys Degradation IR 05000269/19860341987-02-0505 February 1987 Corrected Insp Repts 50-269/86-34,50-270/86-34 & 50-287/86-34 on 861111-870112.Insp Erroneously Reported as Having Been Conducted on 861111-0112 IR 05000269/19870011987-01-30030 January 1987 Insp Repts 50-269/87-01,50-270/87-01 & 50-287/87-01 on 870105-08.Violation Noted:Failure to Provide Procedures W/Appropriate Qualitative or Quantitative Acceptance Criteria for Activities Important to Safety ML20211A0061987-01-23023 January 1987 Insp Repts 50-269/86-34,50-270/86-34 & 50-287/86-34 on 861111-870112.No Violations or Deviations Noted.Major Areas Inspected:Operations,Surveillance,Maint,Verification of ESF Lineups & Emergency Drills IR 05000269/19860351987-01-0707 January 1987 Insp Repts 50-269/86-35,50-270/86-35 & 50-287/86-35 on 861208-12.No Violations or Deviations Noted.Major Areas Inspected:Radiation Protection Program,Including Review of Organization & Mgt of Health Physics Staff ML20212F5511986-12-24024 December 1986 Notice of Violation from Insp on 861103-12 IR 05000269/19860321986-12-10010 December 1986 Insp Repts 50-413/86-44,50-414/86-47,50-369/86-32, 50-370/86-32,50-269/86-32,50-270/86-32 & 50-287/86-32 on 861103-12.Violations Noted:Failure to Follow Procedures for Radiological Sample Analyses & Inadequate Surveys IR 05000269/19860281986-11-0303 November 1986 Partially Withheld Physical Security Insp Repts 50-269/86-28,50-270/86-28 & 50-287/86-28 on 861014-17 (Ref 10CFR2.790 & 73.21).Violation Noted:Inadequate Protected Area Barrier IR 05000269/19860301986-10-23023 October 1986 Partially Withheld Physical Security Insp Rept 50-269/86-30 on 861007-09 (Ref 10CFR2.790 & 73.21).No Violation Noted. Major Areas Inspected:Physical Protection of Irradiated Reactor Fuel During Transportation Between Sites IR 05000269/19860231986-09-23023 September 1986 Insp Repts 50-269/86-23,50-270/86-23 & 50-287/86-23 on 860826-29.No Violation or Deviation Noted.Major Areas Inspected:Inservice Insp,Review of Procedure & Investigation of Techniques Developed for Ultrasonic Exam of Flange IR 05000269/19860241986-09-19019 September 1986 Insp Repts 50-269/86-24,50-270/86-24 & 50-287/86-24 on 860908.No Noncompliance or Deviations Noted.Major Areas Inspected:Operations,Surveillance,Maint,Verification of ESF Lineups & Followup Items IR 05000269/19860211986-08-15015 August 1986 Insp Repts 50-269/86-21,50-270/86-21 & 50-287/86-21 on 860708-0811.No Noncompliance or Deviation Noted.Major Areas Inspected:Operations,Surveillance,Maint,Verification of ESF Lineups & Followup of Events IR 05000269/19860221986-08-0101 August 1986 Partially Withheld Insp Repts 50-269/86-22,50-270/86-22 & 50-287/86-22 on 860711 (Ref 10CFR2.790 & 73.21).Violation Noted:Individual Inside Vital Area Wore Invalid Picture Badge IR 05000269/19860151986-05-28028 May 1986 Insp Rept 50-269/86-15 on 860423-25.No Violations or Deviations Noted.Major Areas Inspected:Ultrasonic Exam of Mockup Reactor vessel-to-flange Weld for Correlation of Reflectors Between Vessel & Mockup IR 05000269/19860071986-05-15015 May 1986 Insp Repts 50-269/86-07,50-270/86-07 & 50-287/86-07 on 860317-0512.No Violations or Deviations Noted.Major Areas Inspected:Low Level Radwaste Burial Site & Startup Review of Low Level Radwaste Incinerator IR 05000269/19860121986-04-25025 April 1986 Insp Repts 50-269/86-12,50-270/86-12 & 50-287/86-12 on 860331-0404.No Violations or Deviations Noted.Major Areas Inspected:Annual Emergency Preparedness Exercise IR 05000269/19860041986-04-0404 April 1986 Insp Repts 50-269/86-04,50-270/86-04 & 50-287/86-04 on 860211-0310.No Violation Noted.Major Areas Inspected: Operations,Surveillance,Maint,Verification of ESF Lineups & Refueling Activities IR 05000269/19860081986-04-0202 April 1986 Insp Repts 50-269/86-08,50-270/86-08 & 50-287/86-08 on 860303-07.No Violation or Deviation Noted.Major Areas Inspected:Unit 1 Sludge Cleaning of once-through Steam Generator by Water Slap Method & IE Bulletin 82-02 ML20199G4451986-03-25025 March 1986 Insp Repts 50-269/86-05,50-270/86-05 & 50-287/86-05 on 860224-28.Violation Noted:Failure to Provide Adequate Respiratory Protective Equipment to Maintain Intakes of Radioactive Matl ALARA IR 05000269/19860091986-03-20020 March 1986 Insp Repts 50-269/86-09,50-270/86-09 & 50-287/86-09 on 860306.No Violation or Deviation Noted.Major Areas Inspected:Steam Generator Cleaning & Maint Re Secondary Water Cycle ML20210H4081986-03-20020 March 1986 Insp Repts 50-269/86-01,50-270/86-01 & 50-287/86-01 on 860114-0210.Violation Noted:Failure to Follow Procedure During Channel C Calibr & Functional Test,Resulting in Reactor Trip from 100% Power IR 05000269/19860061986-03-14014 March 1986 Insp Repts 50-269/86-06,50-270/86-06 & 50-287/86-06 on 860224-27.No Violations or Deviations Noted.Major Areas Inspected:Switchyard Surveillance Testing,Containment Isolation Valve Test Witnessing & Procedure Review IR 05000269/19860031986-03-12012 March 1986 Insp Repts 50-269/86-03,50-270/86-03 & 50-287/86-03 on 860218-21.No Violation or Deviation Noted.Major Areas Inspected:Inservice Insp,Work Observation Data Review & Evaluation & Main Feedwater flow-nozzle Mod IR 05000269/19850421986-02-11011 February 1986 Insp Repts 50-269/85-42,50-270/85-42 & 50-287/85-42 on 851216-20.Violation Noted:Failure to Provide Positive Access Control for Two High Radiation Areas ML20137U5451986-02-11011 February 1986 Insp Repts 50-269/85-41,50-270/85-41 & 50-287/85-41 on 851210-860113.Noncompliance Noted:Failure to Follow Exempt Change Procedure & Failure to Shut Down Reactor within 24 H of Discovery of Excessive Leakage ML20154K8981986-02-0707 February 1986 Insp Repts 50-269/85-39,50-270/85-39 & 50-287/85-39 on 851209-13 & 860114.Violation Identified in Area of Physical Barrier - Protected Area.Rept Details Withheld (Ref 10CFR2.790 & 73.21) IR 05000269/19850401986-01-13013 January 1986 Insp Repts 50-269/85-40,50-270/85-40 & 50-287/85-40 on 851209-13.No Violation or Deviation Identified.Major Areas Inspected:Maint & Surveillance Testing of Main Steam Safety Relief & Pressurizer Code Safety Relief Valves IR 05000269/19850381985-12-13013 December 1985 Insp Repts 50-269/85-38,50-270/85-38 & 50-287/85-38 on 851112-1209.No Noncompliance or Deviations Noted.Major Areas Inspected:Operations,Surveillance,Maint,Startup Testing of Safe Shutdown Facility & LER Review ML20137E4031985-11-21021 November 1985 Insp Repts 50-269/85-37,50-270/85-37 & 50-287/85-37 on 851008-1111.Noncompliance Noted:Failure to Document Malfunctioning Valve 3LP-2 in Reactor Operator & Senior Reactor Operator Log IR 05000269/19850351985-10-28028 October 1985 Insp Repts 50-269/85-35,50-270/85-35 & 50-287/85-35 on 851007-11.No Violation or Deviation Noted.Major Areas Inspected:Review & Witnessing of Pre & post-criticality Tests Following Refueling Outage & Info Notice Followup 1994-01-06
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000269/19930321994-01-0606 January 1994 Insp Repts 50-269/93-32,50-270/93-32,50-287/93-32, 50-369/93-31,50-370/93-31,50-413/93-35 & 50-414,respectively on 931213-17.Violations Noted.Major Areas Inpected:Licensee Safeguards Info Program to folow-up on Licensee Repts IR 05000269/19930061993-03-22022 March 1993 Partially Withheld Insp Repts 50-269/93-06,50-270/93-06 & 50-287/93-06 on 930222-25 (Ref 10CFR73.21).No Violations or Deviations Noted.Major Areas Inspected:Licensee Physical Security Program for Power Reactors IR 05000269/19930011993-02-0101 February 1993 Safeguards Insp Repts 50-269/93-01,50-270/93-01 & 50-287/93-01 on 930104-07.No Violations Noted.Major Areas Inspected:Physical Security Program.Details Withheld (Ref 10CFR73.21) IR 05000269/19920251992-12-0303 December 1992 Insp Repts 50-269/92-25,50-270/92-25 & 50-287/92-25 on 921102-06.No Violations or Deviations Noted.Major Areas Inspected:Physical Security Program for Power Reactors, Audits,Protected & Vital Area Barriers.Details Withheld IR 05000269/19910081991-04-10010 April 1991 Insp Repts 50-269/91-08,50-270/91-08 & 50-287/91-08 on 910312-15.violations Noted.Major Areas Inspected:Maint, Control Room Operation,Planning & Scheduling Activities, Training & Procedures,Plant Physical Condition & Mgmt IR 05000269/19900321990-11-0505 November 1990 Partially Withheld Insp Repts 50-269/90-32,50-270/90-32 & 50-287/90-32 on 901015-19.No Violations Noted.Major Areas Inspected:Physical Security Program Plans,Mgt Support, Security Program Plans & Protected & Vital Area Barriers IR 05000269/19900221990-07-24024 July 1990 Partially Withheld Safeguard Insp Repts 50-269/90-22, 5-270/90-22 & 50-287/90-22 on 900625-29.No Violations or Deviation Noted.Major Areas Inspected:Core Insp Program for Power Reactors & Safeguards Contingency Plan Implementation IR 05000269/19900181990-06-21021 June 1990 Partially Withheld Insp Repts 50-269/90-18,50-270/90-18 & 50-287/90-18 on 900604-08 (Ref 10CFR2.790 & 73.21).No Violations Noted.Major Areas Inspected:Security Program Audit,Detection & Assessment Aids & Key Control IR 05000269/19890201989-07-25025 July 1989 Partially Withheld Insp Repts 50-269/89-20,50-270/89-20 & 50-287/89-20 on 890626-30 (Ref 10CFR2.790.(d) & 73.21). Violations Noted.Major Areas Inspected:Physical Security Program for Power Reactors & Security Audit IR 05000269/19890101989-05-19019 May 1989 Partially Withheld Insp Repts 50-269/89-10,50-270/89-10 & 50-287/89-10 on 890410-14 (Ref 10CFR2.790 & 73.21). Violations Noted.Major Areas Inspected:Mgt Support,Security Program Plans & Audits & Protected & Vital Area Barriers IR 05000269/19890091989-04-10010 April 1989 Insp Repts 50-269/89-09,50-270/89-09 & 50-287/89-09 on 890306-10.No Violations Noted.Weaknesses Noted Re Data Base Used to Prepare computer-generated Work Requests.Major Areas Inspected:Design Control,Mods & Open Items IR 05000269/19890071989-03-10010 March 1989 Insp Repts 50-269/89-07,50-270/89-07 & 50-287/89-07 on 890213-17.Deviation Noted.Major Areas Inspected:Conformance to Reg Guide 1.97 Re Instrumentation for light-water-cooled Plants to Assess Conditions During & Following Accident IR 05000269/19880051988-03-21021 March 1988 Insp Repts 50-269/88-05,50-270/88-05 & 50-287/88-05 on 880217-0316.No Violations Noted.Major Areas Inspected:Maint, Operations,Surveillance,Physical Security & Design Changes IR 05000269/19870101987-03-17017 March 1987 Insp Repts 50-269/87-10,50-270/87-10 & 50-287/87-10 on 870210-0309.No Violations or Deviations Noted.Major Areas Inspected:Areas of Operations,Surveillance,Maint,Followup of Events & Verification of ESF Lineups IR 05000269/19870091987-03-17017 March 1987 Insp Repts 50-269/87-09,50-270/87-09 & 50-287/87-09 on 870209-13.No Violations Noted.Major Areas Inspected:Onsite Review of Liquid & Gaseous Radwaste Programs & Review of TMI Action Items II.B.3 & II.F.1.2 IR 05000269/19870061987-03-0909 March 1987 Insp Repts 50-269/87-06,50-270/87-06 & 50-287/87-06 on 870126-30.No Violations or Deviations Noted.Major Areas Inspected:Inservice Insp,Ongoing Repairs in Reactor Coolant Pumps & Maint & Welding Activities IR 05000269/19870041987-02-17017 February 1987 Insp Repts 50-269/87-04,50-270/87-04 & 50-287/87-04 on 870113-0209.No Violation or Deviation Noted.Major Areas Inspected:Operations,Surveillance,Maint,Verification of ESF Linups,Followup of Events & Shutdown Work in Progress IR 05000269/19870021987-02-11011 February 1987 Partially Withheld Insp Repts 50-269/87-02,50-270/87-02 & 50-287/87-02 on 870126-30 (Ref 10CFR2.790).Violation Noted Re Inadequate App R Circuit Analysis IR 05000269/19870031987-02-10010 February 1987 Insp Repts 50-269/87-03,50-270/87-03 & 50-287/87-03 on 870112-16.Violation Noted:Failure to Adequately Evaluate Radiological Hazards IR 05000269/19870081987-02-0505 February 1987 Enforcement Conference Repts 50-269/87-08,50-270/87-08 & 50-287/87-08 on 861222.Major Areas Discussed:Safety Sys Functional Insp & Associated Safety Implications IR 05000269/19870071987-02-0505 February 1987 Enforcement Conference Repts 50-269/87-07,50-270/87-07 & 50-287/87-07 on 861222.Major Areas Discussed:Sequence of Events & Corrective Actions Re Emergency Condenser Circulating Water Sys Degradation IR 05000269/19860341987-02-0505 February 1987 Corrected Insp Repts 50-269/86-34,50-270/86-34 & 50-287/86-34 on 861111-870112.Insp Erroneously Reported as Having Been Conducted on 861111-0112 IR 05000269/19870011987-01-30030 January 1987 Insp Repts 50-269/87-01,50-270/87-01 & 50-287/87-01 on 870105-08.Violation Noted:Failure to Provide Procedures W/Appropriate Qualitative or Quantitative Acceptance Criteria for Activities Important to Safety ML20211A0061987-01-23023 January 1987 Insp Repts 50-269/86-34,50-270/86-34 & 50-287/86-34 on 861111-870112.No Violations or Deviations Noted.Major Areas Inspected:Operations,Surveillance,Maint,Verification of ESF Lineups & Emergency Drills IR 05000269/19860351987-01-0707 January 1987 Insp Repts 50-269/86-35,50-270/86-35 & 50-287/86-35 on 861208-12.No Violations or Deviations Noted.Major Areas Inspected:Radiation Protection Program,Including Review of Organization & Mgt of Health Physics Staff ML20212F5511986-12-24024 December 1986 Notice of Violation from Insp on 861103-12 IR 05000269/19860321986-12-10010 December 1986 Insp Repts 50-413/86-44,50-414/86-47,50-369/86-32, 50-370/86-32,50-269/86-32,50-270/86-32 & 50-287/86-32 on 861103-12.Violations Noted:Failure to Follow Procedures for Radiological Sample Analyses & Inadequate Surveys IR 05000269/19860281986-11-0303 November 1986 Partially Withheld Physical Security Insp Repts 50-269/86-28,50-270/86-28 & 50-287/86-28 on 861014-17 (Ref 10CFR2.790 & 73.21).Violation Noted:Inadequate Protected Area Barrier IR 05000269/19860301986-10-23023 October 1986 Partially Withheld Physical Security Insp Rept 50-269/86-30 on 861007-09 (Ref 10CFR2.790 & 73.21).No Violation Noted. Major Areas Inspected:Physical Protection of Irradiated Reactor Fuel During Transportation Between Sites IR 05000269/19860231986-09-23023 September 1986 Insp Repts 50-269/86-23,50-270/86-23 & 50-287/86-23 on 860826-29.No Violation or Deviation Noted.Major Areas Inspected:Inservice Insp,Review of Procedure & Investigation of Techniques Developed for Ultrasonic Exam of Flange IR 05000269/19860241986-09-19019 September 1986 Insp Repts 50-269/86-24,50-270/86-24 & 50-287/86-24 on 860908.No Noncompliance or Deviations Noted.Major Areas Inspected:Operations,Surveillance,Maint,Verification of ESF Lineups & Followup Items IR 05000269/19860211986-08-15015 August 1986 Insp Repts 50-269/86-21,50-270/86-21 & 50-287/86-21 on 860708-0811.No Noncompliance or Deviation Noted.Major Areas Inspected:Operations,Surveillance,Maint,Verification of ESF Lineups & Followup of Events IR 05000269/19860221986-08-0101 August 1986 Partially Withheld Insp Repts 50-269/86-22,50-270/86-22 & 50-287/86-22 on 860711 (Ref 10CFR2.790 & 73.21).Violation Noted:Individual Inside Vital Area Wore Invalid Picture Badge IR 05000269/19860151986-05-28028 May 1986 Insp Rept 50-269/86-15 on 860423-25.No Violations or Deviations Noted.Major Areas Inspected:Ultrasonic Exam of Mockup Reactor vessel-to-flange Weld for Correlation of Reflectors Between Vessel & Mockup IR 05000269/19860071986-05-15015 May 1986 Insp Repts 50-269/86-07,50-270/86-07 & 50-287/86-07 on 860317-0512.No Violations or Deviations Noted.Major Areas Inspected:Low Level Radwaste Burial Site & Startup Review of Low Level Radwaste Incinerator IR 05000269/19860121986-04-25025 April 1986 Insp Repts 50-269/86-12,50-270/86-12 & 50-287/86-12 on 860331-0404.No Violations or Deviations Noted.Major Areas Inspected:Annual Emergency Preparedness Exercise IR 05000269/19860041986-04-0404 April 1986 Insp Repts 50-269/86-04,50-270/86-04 & 50-287/86-04 on 860211-0310.No Violation Noted.Major Areas Inspected: Operations,Surveillance,Maint,Verification of ESF Lineups & Refueling Activities IR 05000269/19860081986-04-0202 April 1986 Insp Repts 50-269/86-08,50-270/86-08 & 50-287/86-08 on 860303-07.No Violation or Deviation Noted.Major Areas Inspected:Unit 1 Sludge Cleaning of once-through Steam Generator by Water Slap Method & IE Bulletin 82-02 ML20199G4451986-03-25025 March 1986 Insp Repts 50-269/86-05,50-270/86-05 & 50-287/86-05 on 860224-28.Violation Noted:Failure to Provide Adequate Respiratory Protective Equipment to Maintain Intakes of Radioactive Matl ALARA IR 05000269/19860091986-03-20020 March 1986 Insp Repts 50-269/86-09,50-270/86-09 & 50-287/86-09 on 860306.No Violation or Deviation Noted.Major Areas Inspected:Steam Generator Cleaning & Maint Re Secondary Water Cycle ML20210H4081986-03-20020 March 1986 Insp Repts 50-269/86-01,50-270/86-01 & 50-287/86-01 on 860114-0210.Violation Noted:Failure to Follow Procedure During Channel C Calibr & Functional Test,Resulting in Reactor Trip from 100% Power IR 05000269/19860061986-03-14014 March 1986 Insp Repts 50-269/86-06,50-270/86-06 & 50-287/86-06 on 860224-27.No Violations or Deviations Noted.Major Areas Inspected:Switchyard Surveillance Testing,Containment Isolation Valve Test Witnessing & Procedure Review IR 05000269/19860031986-03-12012 March 1986 Insp Repts 50-269/86-03,50-270/86-03 & 50-287/86-03 on 860218-21.No Violation or Deviation Noted.Major Areas Inspected:Inservice Insp,Work Observation Data Review & Evaluation & Main Feedwater flow-nozzle Mod IR 05000269/19850421986-02-11011 February 1986 Insp Repts 50-269/85-42,50-270/85-42 & 50-287/85-42 on 851216-20.Violation Noted:Failure to Provide Positive Access Control for Two High Radiation Areas ML20137U5451986-02-11011 February 1986 Insp Repts 50-269/85-41,50-270/85-41 & 50-287/85-41 on 851210-860113.Noncompliance Noted:Failure to Follow Exempt Change Procedure & Failure to Shut Down Reactor within 24 H of Discovery of Excessive Leakage ML20154K8981986-02-0707 February 1986 Insp Repts 50-269/85-39,50-270/85-39 & 50-287/85-39 on 851209-13 & 860114.Violation Identified in Area of Physical Barrier - Protected Area.Rept Details Withheld (Ref 10CFR2.790 & 73.21) IR 05000269/19850401986-01-13013 January 1986 Insp Repts 50-269/85-40,50-270/85-40 & 50-287/85-40 on 851209-13.No Violation or Deviation Identified.Major Areas Inspected:Maint & Surveillance Testing of Main Steam Safety Relief & Pressurizer Code Safety Relief Valves IR 05000269/19850381985-12-13013 December 1985 Insp Repts 50-269/85-38,50-270/85-38 & 50-287/85-38 on 851112-1209.No Noncompliance or Deviations Noted.Major Areas Inspected:Operations,Surveillance,Maint,Startup Testing of Safe Shutdown Facility & LER Review ML20137E4031985-11-21021 November 1985 Insp Repts 50-269/85-37,50-270/85-37 & 50-287/85-37 on 851008-1111.Noncompliance Noted:Failure to Document Malfunctioning Valve 3LP-2 in Reactor Operator & Senior Reactor Operator Log IR 05000269/19850351985-10-28028 October 1985 Insp Repts 50-269/85-35,50-270/85-35 & 50-287/85-35 on 851007-11.No Violation or Deviation Noted.Major Areas Inspected:Review & Witnessing of Pre & post-criticality Tests Following Refueling Outage & Info Notice Followup 1994-01-06
[Table view] Category:INSPECTION REPORT
MONTHYEARIR 05000269/19930321994-01-0606 January 1994 Insp Repts 50-269/93-32,50-270/93-32,50-287/93-32, 50-369/93-31,50-370/93-31,50-413/93-35 & 50-414,respectively on 931213-17.Violations Noted.Major Areas Inpected:Licensee Safeguards Info Program to folow-up on Licensee Repts IR 05000269/19930061993-03-22022 March 1993 Partially Withheld Insp Repts 50-269/93-06,50-270/93-06 & 50-287/93-06 on 930222-25 (Ref 10CFR73.21).No Violations or Deviations Noted.Major Areas Inspected:Licensee Physical Security Program for Power Reactors IR 05000269/19930011993-02-0101 February 1993 Safeguards Insp Repts 50-269/93-01,50-270/93-01 & 50-287/93-01 on 930104-07.No Violations Noted.Major Areas Inspected:Physical Security Program.Details Withheld (Ref 10CFR73.21) IR 05000269/19920251992-12-0303 December 1992 Insp Repts 50-269/92-25,50-270/92-25 & 50-287/92-25 on 921102-06.No Violations or Deviations Noted.Major Areas Inspected:Physical Security Program for Power Reactors, Audits,Protected & Vital Area Barriers.Details Withheld IR 05000269/19910081991-04-10010 April 1991 Insp Repts 50-269/91-08,50-270/91-08 & 50-287/91-08 on 910312-15.violations Noted.Major Areas Inspected:Maint, Control Room Operation,Planning & Scheduling Activities, Training & Procedures,Plant Physical Condition & Mgmt IR 05000269/19900321990-11-0505 November 1990 Partially Withheld Insp Repts 50-269/90-32,50-270/90-32 & 50-287/90-32 on 901015-19.No Violations Noted.Major Areas Inspected:Physical Security Program Plans,Mgt Support, Security Program Plans & Protected & Vital Area Barriers IR 05000269/19900221990-07-24024 July 1990 Partially Withheld Safeguard Insp Repts 50-269/90-22, 5-270/90-22 & 50-287/90-22 on 900625-29.No Violations or Deviation Noted.Major Areas Inspected:Core Insp Program for Power Reactors & Safeguards Contingency Plan Implementation IR 05000269/19900181990-06-21021 June 1990 Partially Withheld Insp Repts 50-269/90-18,50-270/90-18 & 50-287/90-18 on 900604-08 (Ref 10CFR2.790 & 73.21).No Violations Noted.Major Areas Inspected:Security Program Audit,Detection & Assessment Aids & Key Control IR 05000269/19890201989-07-25025 July 1989 Partially Withheld Insp Repts 50-269/89-20,50-270/89-20 & 50-287/89-20 on 890626-30 (Ref 10CFR2.790.(d) & 73.21). Violations Noted.Major Areas Inspected:Physical Security Program for Power Reactors & Security Audit IR 05000269/19890101989-05-19019 May 1989 Partially Withheld Insp Repts 50-269/89-10,50-270/89-10 & 50-287/89-10 on 890410-14 (Ref 10CFR2.790 & 73.21). Violations Noted.Major Areas Inspected:Mgt Support,Security Program Plans & Audits & Protected & Vital Area Barriers IR 05000269/19890091989-04-10010 April 1989 Insp Repts 50-269/89-09,50-270/89-09 & 50-287/89-09 on 890306-10.No Violations Noted.Weaknesses Noted Re Data Base Used to Prepare computer-generated Work Requests.Major Areas Inspected:Design Control,Mods & Open Items IR 05000269/19890071989-03-10010 March 1989 Insp Repts 50-269/89-07,50-270/89-07 & 50-287/89-07 on 890213-17.Deviation Noted.Major Areas Inspected:Conformance to Reg Guide 1.97 Re Instrumentation for light-water-cooled Plants to Assess Conditions During & Following Accident IR 05000269/19880051988-03-21021 March 1988 Insp Repts 50-269/88-05,50-270/88-05 & 50-287/88-05 on 880217-0316.No Violations Noted.Major Areas Inspected:Maint, Operations,Surveillance,Physical Security & Design Changes IR 05000269/19870101987-03-17017 March 1987 Insp Repts 50-269/87-10,50-270/87-10 & 50-287/87-10 on 870210-0309.No Violations or Deviations Noted.Major Areas Inspected:Areas of Operations,Surveillance,Maint,Followup of Events & Verification of ESF Lineups IR 05000269/19870091987-03-17017 March 1987 Insp Repts 50-269/87-09,50-270/87-09 & 50-287/87-09 on 870209-13.No Violations Noted.Major Areas Inspected:Onsite Review of Liquid & Gaseous Radwaste Programs & Review of TMI Action Items II.B.3 & II.F.1.2 IR 05000269/19870061987-03-0909 March 1987 Insp Repts 50-269/87-06,50-270/87-06 & 50-287/87-06 on 870126-30.No Violations or Deviations Noted.Major Areas Inspected:Inservice Insp,Ongoing Repairs in Reactor Coolant Pumps & Maint & Welding Activities IR 05000269/19870041987-02-17017 February 1987 Insp Repts 50-269/87-04,50-270/87-04 & 50-287/87-04 on 870113-0209.No Violation or Deviation Noted.Major Areas Inspected:Operations,Surveillance,Maint,Verification of ESF Linups,Followup of Events & Shutdown Work in Progress IR 05000269/19870021987-02-11011 February 1987 Partially Withheld Insp Repts 50-269/87-02,50-270/87-02 & 50-287/87-02 on 870126-30 (Ref 10CFR2.790).Violation Noted Re Inadequate App R Circuit Analysis IR 05000269/19870031987-02-10010 February 1987 Insp Repts 50-269/87-03,50-270/87-03 & 50-287/87-03 on 870112-16.Violation Noted:Failure to Adequately Evaluate Radiological Hazards IR 05000269/19870081987-02-0505 February 1987 Enforcement Conference Repts 50-269/87-08,50-270/87-08 & 50-287/87-08 on 861222.Major Areas Discussed:Safety Sys Functional Insp & Associated Safety Implications IR 05000269/19870071987-02-0505 February 1987 Enforcement Conference Repts 50-269/87-07,50-270/87-07 & 50-287/87-07 on 861222.Major Areas Discussed:Sequence of Events & Corrective Actions Re Emergency Condenser Circulating Water Sys Degradation IR 05000269/19860341987-02-0505 February 1987 Corrected Insp Repts 50-269/86-34,50-270/86-34 & 50-287/86-34 on 861111-870112.Insp Erroneously Reported as Having Been Conducted on 861111-0112 IR 05000269/19870011987-01-30030 January 1987 Insp Repts 50-269/87-01,50-270/87-01 & 50-287/87-01 on 870105-08.Violation Noted:Failure to Provide Procedures W/Appropriate Qualitative or Quantitative Acceptance Criteria for Activities Important to Safety ML20211A0061987-01-23023 January 1987 Insp Repts 50-269/86-34,50-270/86-34 & 50-287/86-34 on 861111-870112.No Violations or Deviations Noted.Major Areas Inspected:Operations,Surveillance,Maint,Verification of ESF Lineups & Emergency Drills IR 05000269/19860351987-01-0707 January 1987 Insp Repts 50-269/86-35,50-270/86-35 & 50-287/86-35 on 861208-12.No Violations or Deviations Noted.Major Areas Inspected:Radiation Protection Program,Including Review of Organization & Mgt of Health Physics Staff ML20212F5511986-12-24024 December 1986 Notice of Violation from Insp on 861103-12 IR 05000269/19860321986-12-10010 December 1986 Insp Repts 50-413/86-44,50-414/86-47,50-369/86-32, 50-370/86-32,50-269/86-32,50-270/86-32 & 50-287/86-32 on 861103-12.Violations Noted:Failure to Follow Procedures for Radiological Sample Analyses & Inadequate Surveys IR 05000269/19860281986-11-0303 November 1986 Partially Withheld Physical Security Insp Repts 50-269/86-28,50-270/86-28 & 50-287/86-28 on 861014-17 (Ref 10CFR2.790 & 73.21).Violation Noted:Inadequate Protected Area Barrier IR 05000269/19860301986-10-23023 October 1986 Partially Withheld Physical Security Insp Rept 50-269/86-30 on 861007-09 (Ref 10CFR2.790 & 73.21).No Violation Noted. Major Areas Inspected:Physical Protection of Irradiated Reactor Fuel During Transportation Between Sites IR 05000269/19860231986-09-23023 September 1986 Insp Repts 50-269/86-23,50-270/86-23 & 50-287/86-23 on 860826-29.No Violation or Deviation Noted.Major Areas Inspected:Inservice Insp,Review of Procedure & Investigation of Techniques Developed for Ultrasonic Exam of Flange IR 05000269/19860241986-09-19019 September 1986 Insp Repts 50-269/86-24,50-270/86-24 & 50-287/86-24 on 860908.No Noncompliance or Deviations Noted.Major Areas Inspected:Operations,Surveillance,Maint,Verification of ESF Lineups & Followup Items IR 05000269/19860211986-08-15015 August 1986 Insp Repts 50-269/86-21,50-270/86-21 & 50-287/86-21 on 860708-0811.No Noncompliance or Deviation Noted.Major Areas Inspected:Operations,Surveillance,Maint,Verification of ESF Lineups & Followup of Events IR 05000269/19860221986-08-0101 August 1986 Partially Withheld Insp Repts 50-269/86-22,50-270/86-22 & 50-287/86-22 on 860711 (Ref 10CFR2.790 & 73.21).Violation Noted:Individual Inside Vital Area Wore Invalid Picture Badge IR 05000269/19860151986-05-28028 May 1986 Insp Rept 50-269/86-15 on 860423-25.No Violations or Deviations Noted.Major Areas Inspected:Ultrasonic Exam of Mockup Reactor vessel-to-flange Weld for Correlation of Reflectors Between Vessel & Mockup IR 05000269/19860071986-05-15015 May 1986 Insp Repts 50-269/86-07,50-270/86-07 & 50-287/86-07 on 860317-0512.No Violations or Deviations Noted.Major Areas Inspected:Low Level Radwaste Burial Site & Startup Review of Low Level Radwaste Incinerator IR 05000269/19860121986-04-25025 April 1986 Insp Repts 50-269/86-12,50-270/86-12 & 50-287/86-12 on 860331-0404.No Violations or Deviations Noted.Major Areas Inspected:Annual Emergency Preparedness Exercise IR 05000269/19860041986-04-0404 April 1986 Insp Repts 50-269/86-04,50-270/86-04 & 50-287/86-04 on 860211-0310.No Violation Noted.Major Areas Inspected: Operations,Surveillance,Maint,Verification of ESF Lineups & Refueling Activities IR 05000269/19860081986-04-0202 April 1986 Insp Repts 50-269/86-08,50-270/86-08 & 50-287/86-08 on 860303-07.No Violation or Deviation Noted.Major Areas Inspected:Unit 1 Sludge Cleaning of once-through Steam Generator by Water Slap Method & IE Bulletin 82-02 ML20199G4451986-03-25025 March 1986 Insp Repts 50-269/86-05,50-270/86-05 & 50-287/86-05 on 860224-28.Violation Noted:Failure to Provide Adequate Respiratory Protective Equipment to Maintain Intakes of Radioactive Matl ALARA IR 05000269/19860091986-03-20020 March 1986 Insp Repts 50-269/86-09,50-270/86-09 & 50-287/86-09 on 860306.No Violation or Deviation Noted.Major Areas Inspected:Steam Generator Cleaning & Maint Re Secondary Water Cycle ML20210H4081986-03-20020 March 1986 Insp Repts 50-269/86-01,50-270/86-01 & 50-287/86-01 on 860114-0210.Violation Noted:Failure to Follow Procedure During Channel C Calibr & Functional Test,Resulting in Reactor Trip from 100% Power IR 05000269/19860061986-03-14014 March 1986 Insp Repts 50-269/86-06,50-270/86-06 & 50-287/86-06 on 860224-27.No Violations or Deviations Noted.Major Areas Inspected:Switchyard Surveillance Testing,Containment Isolation Valve Test Witnessing & Procedure Review IR 05000269/19860031986-03-12012 March 1986 Insp Repts 50-269/86-03,50-270/86-03 & 50-287/86-03 on 860218-21.No Violation or Deviation Noted.Major Areas Inspected:Inservice Insp,Work Observation Data Review & Evaluation & Main Feedwater flow-nozzle Mod IR 05000269/19850421986-02-11011 February 1986 Insp Repts 50-269/85-42,50-270/85-42 & 50-287/85-42 on 851216-20.Violation Noted:Failure to Provide Positive Access Control for Two High Radiation Areas ML20137U5451986-02-11011 February 1986 Insp Repts 50-269/85-41,50-270/85-41 & 50-287/85-41 on 851210-860113.Noncompliance Noted:Failure to Follow Exempt Change Procedure & Failure to Shut Down Reactor within 24 H of Discovery of Excessive Leakage ML20154K8981986-02-0707 February 1986 Insp Repts 50-269/85-39,50-270/85-39 & 50-287/85-39 on 851209-13 & 860114.Violation Identified in Area of Physical Barrier - Protected Area.Rept Details Withheld (Ref 10CFR2.790 & 73.21) IR 05000269/19850401986-01-13013 January 1986 Insp Repts 50-269/85-40,50-270/85-40 & 50-287/85-40 on 851209-13.No Violation or Deviation Identified.Major Areas Inspected:Maint & Surveillance Testing of Main Steam Safety Relief & Pressurizer Code Safety Relief Valves IR 05000269/19850381985-12-13013 December 1985 Insp Repts 50-269/85-38,50-270/85-38 & 50-287/85-38 on 851112-1209.No Noncompliance or Deviations Noted.Major Areas Inspected:Operations,Surveillance,Maint,Startup Testing of Safe Shutdown Facility & LER Review ML20137E4031985-11-21021 November 1985 Insp Repts 50-269/85-37,50-270/85-37 & 50-287/85-37 on 851008-1111.Noncompliance Noted:Failure to Document Malfunctioning Valve 3LP-2 in Reactor Operator & Senior Reactor Operator Log IR 05000269/19850351985-10-28028 October 1985 Insp Repts 50-269/85-35,50-270/85-35 & 50-287/85-35 on 851007-11.No Violation or Deviation Noted.Major Areas Inspected:Review & Witnessing of Pre & post-criticality Tests Following Refueling Outage & Info Notice Followup 1994-01-06
[Table view] Category:UTILITY
MONTHYEARIR 05000269/19900321990-11-0505 November 1990 Partially Withheld Insp Repts 50-269/90-32,50-270/90-32 & 50-287/90-32 on 901015-19.No Violations Noted.Major Areas Inspected:Physical Security Program Plans,Mgt Support, Security Program Plans & Protected & Vital Area Barriers IR 05000269/19900221990-07-24024 July 1990 Partially Withheld Safeguard Insp Repts 50-269/90-22, 5-270/90-22 & 50-287/90-22 on 900625-29.No Violations or Deviation Noted.Major Areas Inspected:Core Insp Program for Power Reactors & Safeguards Contingency Plan Implementation IR 05000269/19900181990-06-21021 June 1990 Partially Withheld Insp Repts 50-269/90-18,50-270/90-18 & 50-287/90-18 on 900604-08 (Ref 10CFR2.790 & 73.21).No Violations Noted.Major Areas Inspected:Security Program Audit,Detection & Assessment Aids & Key Control IR 05000269/19890201989-07-25025 July 1989 Partially Withheld Insp Repts 50-269/89-20,50-270/89-20 & 50-287/89-20 on 890626-30 (Ref 10CFR2.790.(d) & 73.21). Violations Noted.Major Areas Inspected:Physical Security Program for Power Reactors & Security Audit IR 05000269/19890091989-04-10010 April 1989 Insp Repts 50-269/89-09,50-270/89-09 & 50-287/89-09 on 890306-10.No Violations Noted.Weaknesses Noted Re Data Base Used to Prepare computer-generated Work Requests.Major Areas Inspected:Design Control,Mods & Open Items IR 05000269/19890071989-03-10010 March 1989 Insp Repts 50-269/89-07,50-270/89-07 & 50-287/89-07 on 890213-17.Deviation Noted.Major Areas Inspected:Conformance to Reg Guide 1.97 Re Instrumentation for light-water-cooled Plants to Assess Conditions During & Following Accident IR 05000269/19880051988-03-21021 March 1988 Insp Repts 50-269/88-05,50-270/88-05 & 50-287/88-05 on 880217-0316.No Violations Noted.Major Areas Inspected:Maint, Operations,Surveillance,Physical Security & Design Changes IR 05000269/19870101987-03-17017 March 1987 Insp Repts 50-269/87-10,50-270/87-10 & 50-287/87-10 on 870210-0309.No Violations or Deviations Noted.Major Areas Inspected:Areas of Operations,Surveillance,Maint,Followup of Events & Verification of ESF Lineups IR 05000269/19870091987-03-17017 March 1987 Insp Repts 50-269/87-09,50-270/87-09 & 50-287/87-09 on 870209-13.No Violations Noted.Major Areas Inspected:Onsite Review of Liquid & Gaseous Radwaste Programs & Review of TMI Action Items II.B.3 & II.F.1.2 IR 05000269/19870061987-03-0909 March 1987 Insp Repts 50-269/87-06,50-270/87-06 & 50-287/87-06 on 870126-30.No Violations or Deviations Noted.Major Areas Inspected:Inservice Insp,Ongoing Repairs in Reactor Coolant Pumps & Maint & Welding Activities IR 05000269/19870041987-02-17017 February 1987 Insp Repts 50-269/87-04,50-270/87-04 & 50-287/87-04 on 870113-0209.No Violation or Deviation Noted.Major Areas Inspected:Operations,Surveillance,Maint,Verification of ESF Linups,Followup of Events & Shutdown Work in Progress IR 05000269/19870021987-02-11011 February 1987 Partially Withheld Insp Repts 50-269/87-02,50-270/87-02 & 50-287/87-02 on 870126-30 (Ref 10CFR2.790).Violation Noted Re Inadequate App R Circuit Analysis IR 05000269/19870031987-02-10010 February 1987 Insp Repts 50-269/87-03,50-270/87-03 & 50-287/87-03 on 870112-16.Violation Noted:Failure to Adequately Evaluate Radiological Hazards IR 05000269/19860341987-02-0505 February 1987 Corrected Insp Repts 50-269/86-34,50-270/86-34 & 50-287/86-34 on 861111-870112.Insp Erroneously Reported as Having Been Conducted on 861111-0112 IR 05000269/19870071987-02-0505 February 1987 Enforcement Conference Repts 50-269/87-07,50-270/87-07 & 50-287/87-07 on 861222.Major Areas Discussed:Sequence of Events & Corrective Actions Re Emergency Condenser Circulating Water Sys Degradation IR 05000269/19870081987-02-0505 February 1987 Enforcement Conference Repts 50-269/87-08,50-270/87-08 & 50-287/87-08 on 861222.Major Areas Discussed:Safety Sys Functional Insp & Associated Safety Implications IR 05000269/19870011987-01-30030 January 1987 Insp Repts 50-269/87-01,50-270/87-01 & 50-287/87-01 on 870105-08.Violation Noted:Failure to Provide Procedures W/Appropriate Qualitative or Quantitative Acceptance Criteria for Activities Important to Safety ML20211A0061987-01-23023 January 1987 Insp Repts 50-269/86-34,50-270/86-34 & 50-287/86-34 on 861111-870112.No Violations or Deviations Noted.Major Areas Inspected:Operations,Surveillance,Maint,Verification of ESF Lineups & Emergency Drills IR 05000269/19860351987-01-0707 January 1987 Insp Repts 50-269/86-35,50-270/86-35 & 50-287/86-35 on 861208-12.No Violations or Deviations Noted.Major Areas Inspected:Radiation Protection Program,Including Review of Organization & Mgt of Health Physics Staff IR 05000269/19860321986-12-10010 December 1986 Insp Repts 50-413/86-44,50-414/86-47,50-369/86-32, 50-370/86-32,50-269/86-32,50-270/86-32 & 50-287/86-32 on 861103-12.Violations Noted:Failure to Follow Procedures for Radiological Sample Analyses & Inadequate Surveys IR 05000269/19860281986-11-0303 November 1986 Partially Withheld Physical Security Insp Repts 50-269/86-28,50-270/86-28 & 50-287/86-28 on 861014-17 (Ref 10CFR2.790 & 73.21).Violation Noted:Inadequate Protected Area Barrier IR 05000269/19860301986-10-23023 October 1986 Partially Withheld Physical Security Insp Rept 50-269/86-30 on 861007-09 (Ref 10CFR2.790 & 73.21).No Violation Noted. Major Areas Inspected:Physical Protection of Irradiated Reactor Fuel During Transportation Between Sites IR 05000269/19860231986-09-23023 September 1986 Insp Repts 50-269/86-23,50-270/86-23 & 50-287/86-23 on 860826-29.No Violation or Deviation Noted.Major Areas Inspected:Inservice Insp,Review of Procedure & Investigation of Techniques Developed for Ultrasonic Exam of Flange IR 05000269/19860241986-09-19019 September 1986 Insp Repts 50-269/86-24,50-270/86-24 & 50-287/86-24 on 860908.No Noncompliance or Deviations Noted.Major Areas Inspected:Operations,Surveillance,Maint,Verification of ESF Lineups & Followup Items IR 05000269/19860211986-08-15015 August 1986 Insp Repts 50-269/86-21,50-270/86-21 & 50-287/86-21 on 860708-0811.No Noncompliance or Deviation Noted.Major Areas Inspected:Operations,Surveillance,Maint,Verification of ESF Lineups & Followup of Events IR 05000269/19860221986-08-0101 August 1986 Partially Withheld Insp Repts 50-269/86-22,50-270/86-22 & 50-287/86-22 on 860711 (Ref 10CFR2.790 & 73.21).Violation Noted:Individual Inside Vital Area Wore Invalid Picture Badge IR 05000269/19860151986-05-28028 May 1986 Insp Rept 50-269/86-15 on 860423-25.No Violations or Deviations Noted.Major Areas Inspected:Ultrasonic Exam of Mockup Reactor vessel-to-flange Weld for Correlation of Reflectors Between Vessel & Mockup IR 05000269/19860121986-04-25025 April 1986 Insp Repts 50-269/86-12,50-270/86-12 & 50-287/86-12 on 860331-0404.No Violations or Deviations Noted.Major Areas Inspected:Annual Emergency Preparedness Exercise IR 05000269/19860041986-04-0404 April 1986 Insp Repts 50-269/86-04,50-270/86-04 & 50-287/86-04 on 860211-0310.No Violation Noted.Major Areas Inspected: Operations,Surveillance,Maint,Verification of ESF Lineups & Refueling Activities IR 05000269/19860081986-04-0202 April 1986 Insp Repts 50-269/86-08,50-270/86-08 & 50-287/86-08 on 860303-07.No Violation or Deviation Noted.Major Areas Inspected:Unit 1 Sludge Cleaning of once-through Steam Generator by Water Slap Method & IE Bulletin 82-02 ML20199G4451986-03-25025 March 1986 Insp Repts 50-269/86-05,50-270/86-05 & 50-287/86-05 on 860224-28.Violation Noted:Failure to Provide Adequate Respiratory Protective Equipment to Maintain Intakes of Radioactive Matl ALARA IR 05000269/19860091986-03-20020 March 1986 Insp Repts 50-269/86-09,50-270/86-09 & 50-287/86-09 on 860306.No Violation or Deviation Noted.Major Areas Inspected:Steam Generator Cleaning & Maint Re Secondary Water Cycle ML20210H4081986-03-20020 March 1986 Insp Repts 50-269/86-01,50-270/86-01 & 50-287/86-01 on 860114-0210.Violation Noted:Failure to Follow Procedure During Channel C Calibr & Functional Test,Resulting in Reactor Trip from 100% Power IR 05000269/19860061986-03-14014 March 1986 Insp Repts 50-269/86-06,50-270/86-06 & 50-287/86-06 on 860224-27.No Violations or Deviations Noted.Major Areas Inspected:Switchyard Surveillance Testing,Containment Isolation Valve Test Witnessing & Procedure Review IR 05000269/19860031986-03-12012 March 1986 Insp Repts 50-269/86-03,50-270/86-03 & 50-287/86-03 on 860218-21.No Violation or Deviation Noted.Major Areas Inspected:Inservice Insp,Work Observation Data Review & Evaluation & Main Feedwater flow-nozzle Mod IR 05000269/19850421986-02-11011 February 1986 Insp Repts 50-269/85-42,50-270/85-42 & 50-287/85-42 on 851216-20.Violation Noted:Failure to Provide Positive Access Control for Two High Radiation Areas ML20137U5451986-02-11011 February 1986 Insp Repts 50-269/85-41,50-270/85-41 & 50-287/85-41 on 851210-860113.Noncompliance Noted:Failure to Follow Exempt Change Procedure & Failure to Shut Down Reactor within 24 H of Discovery of Excessive Leakage ML20154K8981986-02-0707 February 1986 Insp Repts 50-269/85-39,50-270/85-39 & 50-287/85-39 on 851209-13 & 860114.Violation Identified in Area of Physical Barrier - Protected Area.Rept Details Withheld (Ref 10CFR2.790 & 73.21) IR 05000269/19850401986-01-13013 January 1986 Insp Repts 50-269/85-40,50-270/85-40 & 50-287/85-40 on 851209-13.No Violation or Deviation Identified.Major Areas Inspected:Maint & Surveillance Testing of Main Steam Safety Relief & Pressurizer Code Safety Relief Valves IR 05000269/19850381985-12-13013 December 1985 Insp Repts 50-269/85-38,50-270/85-38 & 50-287/85-38 on 851112-1209.No Noncompliance or Deviations Noted.Major Areas Inspected:Operations,Surveillance,Maint,Startup Testing of Safe Shutdown Facility & LER Review ML20137E4031985-11-21021 November 1985 Insp Repts 50-269/85-37,50-270/85-37 & 50-287/85-37 on 851008-1111.Noncompliance Noted:Failure to Document Malfunctioning Valve 3LP-2 in Reactor Operator & Senior Reactor Operator Log IR 05000269/19850351985-10-28028 October 1985 Insp Repts 50-269/85-35,50-270/85-35 & 50-287/85-35 on 851007-11.No Violation or Deviation Noted.Major Areas Inspected:Review & Witnessing of Pre & post-criticality Tests Following Refueling Outage & Info Notice Followup IR 05000269/19850341985-10-24024 October 1985 Insp Repts 50-269/85-34,50-270/85-34 & 50-287/85-34 on 850930-1004.No Violation or Deviation Noted.Major Areas Inspected:Fire Protection/Prevention & Followup on Previously Identified Items IR 05000269/19850321985-10-23023 October 1985 Insp Repts 50-269/85-32,50-270/85-32 & 50-287/85-32 on 850910-1007.No Noncompliance or Deviation Noted.Major Areas Inspected:Operations,Surveillance,Maint,Offsite Review Committee & Startup from Refueling IR 05000269/19850331985-10-17017 October 1985 Insp Repts 50-269/85-33,50-270/85-33 & 50-287/85-33 on 850923-26.No Violation or Deviation Noted.Major Areas Inspected:Unit 3 Inservice Insp,Review & Record Evaluation & Main Feedwater Flow Nozzle post-weld Heat Treatment IR 05000269/19850311985-10-11011 October 1985 Insp Repts 50-269/85-31,50-270/85-31 & 50-287/85-31 on 850923-27.No Violation or Deviation Noted.Major Areas Inspected:Reactor Bldg Tendon Surveillance Program & Surveillance of Pipe Support & Restraints ML20138M5601985-10-0808 October 1985 Insp Repts 50-269/85-30,50-270/85-30 & 50-287/85-30 on 850916-20.Violation Noted:Failure to Label Containers of Radioactive Matl ML20141A0191985-10-0202 October 1985 Insp Repts 50-269/85-28,50-270/85-28 & 50-287/85-28 on 850903-06.Violation Noted:Inadequate Procedure for Documentation of Vital Area Barrier Insp.Details Withheld (Ref 10CFR2.790(d) & 73.21) ML20133C7481985-09-24024 September 1985 Insp Repts 50-269/85-27,50-270/85-27 & 50-287/85-27 on 850903-06.Violations Noted:Failure to Use Qualified Weld Procedures & to Obtain Final QA Approval on Reactor Coolant Pump Replacement Bolts Prior to Startup ML20132C2821985-09-13013 September 1985 Insp Repts 50-269/85-26,50-270/85-26 & 50-287/85-26 on 850813-0909.Violation Noted:Failure to Follow Procedures for E-bar Determination 1990-07-24
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARPNO-II-97-065, on 971228,initiated Controlled Shutdown of Unit Due to Exceeding TS Leakage Limit of 150 Gpd.Licensee Continuing W/Plant Depressurization & Cooldown & Outage Planned of Several Days to Investigate & Repair SG1997-12-29029 December 1997 PNO-II-97-065:on 971228,initiated Controlled Shutdown of Unit Due to Exceeding TS Leakage Limit of 150 Gpd.Licensee Continuing W/Plant Depressurization & Cooldown & Outage Planned of Several Days to Investigate & Repair SG ML20211K9431997-09-26026 September 1997 Notice of Violation from Insp on 970721-26.Violation Noted: Licensee Failed to Follow Procedures for Security Badges & Access Control of Facility ML20210S0391997-08-27027 August 1997 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $330,000.Violation Noted:Between 970501-02,w/ Fuel in Oconee Unit 3 Core & RCS Temp Greater than 350 F, Licensee Failed to Maintain HPI Sys Operable as Required PNO-II-97-034, on 970613,extended Shutdown to Meet CAL 2-97-03 Commitments to Shutdown Unit 1 No Later than 970614 & to Implement Actions Re HPI Sys.Nrc Resident Inspector Will Followup on Unit 1 Shutdown & Recovery Activities1997-06-13013 June 1997 PNO-II-97-034:on 970613,extended Shutdown to Meet CAL 2-97-03 Commitments to Shutdown Unit 1 No Later than 970614 & to Implement Actions Re HPI Sys.Nrc Resident Inspector Will Followup on Unit 1 Shutdown & Recovery Activities IR 05000269/19930321994-01-0606 January 1994 Insp Repts 50-269/93-32,50-270/93-32,50-287/93-32, 50-369/93-31,50-370/93-31,50-413/93-35 & 50-414,respectively on 931213-17.Violations Noted.Major Areas Inpected:Licensee Safeguards Info Program to folow-up on Licensee Repts PNO-II-93-039, on 930823,reactor Trip Occurred Due to Loss of Power to Vital Panelboard.Investigation Team Dispatched to Site to Review Root Cause & Plant Response.State & Local Authorities Notified1993-08-24024 August 1993 PNO-II-93-039:on 930823,reactor Trip Occurred Due to Loss of Power to Vital Panelboard.Investigation Team Dispatched to Site to Review Root Cause & Plant Response.State & Local Authorities Notified IR 05000269/19930061993-03-22022 March 1993 Partially Withheld Insp Repts 50-269/93-06,50-270/93-06 & 50-287/93-06 on 930222-25 (Ref 10CFR73.21).No Violations or Deviations Noted.Major Areas Inspected:Licensee Physical Security Program for Power Reactors IR 05000269/19930011993-02-0101 February 1993 Safeguards Insp Repts 50-269/93-01,50-270/93-01 & 50-287/93-01 on 930104-07.No Violations Noted.Major Areas Inspected:Physical Security Program.Details Withheld (Ref 10CFR73.21) IR 05000269/19920251992-12-0303 December 1992 Insp Repts 50-269/92-25,50-270/92-25 & 50-287/92-25 on 921102-06.No Violations or Deviations Noted.Major Areas Inspected:Physical Security Program for Power Reactors, Audits,Protected & Vital Area Barriers.Details Withheld PNO-II-92-070, on 921019,several Circuit Breakers Failed in 230KV Switchyard to Open Position for Unknown Reasons. Licensee Has Inititated Investigation to Review Event to Determine Cause & Determine Why Certain Equipment Failed1992-10-20020 October 1992 PNO-II-92-070:on 921019,several Circuit Breakers Failed in 230KV Switchyard to Open Position for Unknown Reasons. Licensee Has Inititated Investigation to Review Event to Determine Cause & Determine Why Certain Equipment Failed PNO-II-91-074B, on 911123,unit Remained in Cold Shutdown,Per Declaration of Alert at 0214 Due to Leak in Rcs.As of 911126,total of 7,800 Gallons of Treated Water Released from Plant to Lake Hartwell1991-11-26026 November 1991 PNO-II-91-074B:on 911123,unit Remained in Cold Shutdown,Per Declaration of Alert at 0214 Due to Leak in Rcs.As of 911126,total of 7,800 Gallons of Treated Water Released from Plant to Lake Hartwell ML20134D2581991-06-0404 June 1991 Notice of Violation from Insp on 910312-15.Violations Noted:Station Was Not Maintained According to Main Procedure MP/0/A/1800/105,Section 6.5,which Clearly Identified That Flange Was to Be Installed on Valve 3LP19 IR 05000269/19910081991-04-10010 April 1991 Insp Repts 50-269/91-08,50-270/91-08 & 50-287/91-08 on 910312-15.violations Noted.Major Areas Inspected:Maint, Control Room Operation,Planning & Scheduling Activities, Training & Procedures,Plant Physical Condition & Mgmt PNO-II-90-070, on 901108,unit Commenced Controlled Shutdown from 60% Power Due to Tube Leak in Steam Generator a1990-11-0808 November 1990 PNO-II-90-070:on 901108,unit Commenced Controlled Shutdown from 60% Power Due to Tube Leak in Steam Generator a IR 05000269/19900321990-11-0505 November 1990 Partially Withheld Insp Repts 50-269/90-32,50-270/90-32 & 50-287/90-32 on 901015-19.No Violations Noted.Major Areas Inspected:Physical Security Program Plans,Mgt Support, Security Program Plans & Protected & Vital Area Barriers IR 05000269/19900241990-10-0202 October 1990 SALP Repts 50-269/90-24,50-270/90-24,50-287/90-24 & 72-0004/90-24 for Feb 1989 - Jul 1990 IR 05000269/19900221990-07-24024 July 1990 Partially Withheld Safeguard Insp Repts 50-269/90-22, 5-270/90-22 & 50-287/90-22 on 900625-29.No Violations or Deviation Noted.Major Areas Inspected:Core Insp Program for Power Reactors & Safeguards Contingency Plan Implementation IR 05000269/19900181990-06-21021 June 1990 Partially Withheld Insp Repts 50-269/90-18,50-270/90-18 & 50-287/90-18 on 900604-08 (Ref 10CFR2.790 & 73.21).No Violations Noted.Major Areas Inspected:Security Program Audit,Detection & Assessment Aids & Key Control IR 05000269/19890201989-07-25025 July 1989 Partially Withheld Insp Repts 50-269/89-20,50-270/89-20 & 50-287/89-20 on 890626-30 (Ref 10CFR2.790.(d) & 73.21). Violations Noted.Major Areas Inspected:Physical Security Program for Power Reactors & Security Audit IR 05000269/19890101989-05-19019 May 1989 Partially Withheld Insp Repts 50-269/89-10,50-270/89-10 & 50-287/89-10 on 890410-14 (Ref 10CFR2.790 & 73.21). Violations Noted.Major Areas Inspected:Mgt Support,Security Program Plans & Audits & Protected & Vital Area Barriers IR 05000269/19890091989-04-10010 April 1989 Insp Repts 50-269/89-09,50-270/89-09 & 50-287/89-09 on 890306-10.No Violations Noted.Weaknesses Noted Re Data Base Used to Prepare computer-generated Work Requests.Major Areas Inspected:Design Control,Mods & Open Items IR 05000269/19890071989-03-10010 March 1989 Insp Repts 50-269/89-07,50-270/89-07 & 50-287/89-07 on 890213-17.Deviation Noted.Major Areas Inspected:Conformance to Reg Guide 1.97 Re Instrumentation for light-water-cooled Plants to Assess Conditions During & Following Accident IR 05000269/19880051988-03-21021 March 1988 Insp Repts 50-269/88-05,50-270/88-05 & 50-287/88-05 on 880217-0316.No Violations Noted.Major Areas Inspected:Maint, Operations,Surveillance,Physical Security & Design Changes PNO-II-88-013, on 880211,two Workers Slightly Contaminated W/ Radioactive Water.Caused by Approx 1,000 Gallon Leak of Radioactive Water Occurring During Maint on Valve.Workers Showered to Remove Contamination1988-02-12012 February 1988 PNO-II-88-013:on 880211,two Workers Slightly Contaminated W/ Radioactive Water.Caused by Approx 1,000 Gallon Leak of Radioactive Water Occurring During Maint on Valve.Workers Showered to Remove Contamination ML20237B2261987-12-15015 December 1987 EN-87-017A:informs That 870309 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $25,000 Withdrawn Due to Determination That Violation Did Not Occur. Violation Based on Failure of Emergency Feedwater Pumps ML20235T5821987-09-18018 September 1987 Exam Rept 50-269/OL-87-02 on 870713-23.Exam Results:Seven of Ten Reactor Operator (RO) & Eight of Nine Senior Reactor Operator (SRO) Candidates Passed Written Exam.All RO & SRO Candidates Passed Operating Exam ML20238F7081987-09-0909 September 1987 Exam Rept 50-269/OL-87-01 for Units 1,2 & 3 on 870713-17. Exam results:7 of 10 Reactor Operators & 3 of 6 Senior Reactor Operators Passed ML20236E5111987-07-14014 July 1987 EN-86-056:on 870717,notice of Violation & Proposed Imposition of Civil Penalty in Amount of $25,000 Will Be Issued to Licensee.Action Based on Failure to Properly Implement Startup Procedure Causing Trains to Fail IR 05000269/19870091987-03-17017 March 1987 Insp Repts 50-269/87-09,50-270/87-09 & 50-287/87-09 on 870209-13.No Violations Noted.Major Areas Inspected:Onsite Review of Liquid & Gaseous Radwaste Programs & Review of TMI Action Items II.B.3 & II.F.1.2 IR 05000269/19870101987-03-17017 March 1987 Insp Repts 50-269/87-10,50-270/87-10 & 50-287/87-10 on 870210-0309.No Violations or Deviations Noted.Major Areas Inspected:Areas of Operations,Surveillance,Maint,Followup of Events & Verification of ESF Lineups ML20207T5431987-03-12012 March 1987 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $25,000.Noncompliance Noted:Measures Not Established to Assure That Regulatory Requirements & Design Bases Correctly Translated Into Specs,Drawings & Procedures IR 05000269/19870061987-03-0909 March 1987 Insp Repts 50-269/87-06,50-270/87-06 & 50-287/87-06 on 870126-30.No Violations or Deviations Noted.Major Areas Inspected:Inservice Insp,Ongoing Repairs in Reactor Coolant Pumps & Maint & Welding Activities ML20207R4851987-03-0909 March 1987 EN-87-017:on 870312,notice of Violation & Proposed Imposition of Civil Penalty in Amount of $25,000 Will Be Issued to Util Based on Failure to Provide Adequate Design Control to Ensure Emergency Feedwater Pump Operability IR 05000269/19870041987-02-17017 February 1987 Insp Repts 50-269/87-04,50-270/87-04 & 50-287/87-04 on 870113-0209.No Violation or Deviation Noted.Major Areas Inspected:Operations,Surveillance,Maint,Verification of ESF Linups,Followup of Events & Shutdown Work in Progress IR 05000269/19870021987-02-11011 February 1987 Partially Withheld Insp Repts 50-269/87-02,50-270/87-02 & 50-287/87-02 on 870126-30 (Ref 10CFR2.790).Violation Noted Re Inadequate App R Circuit Analysis ML20211A4991987-02-11011 February 1987 Notice of Violation from Insps on 870112-16 IR 05000269/19870031987-02-10010 February 1987 Insp Repts 50-269/87-03,50-270/87-03 & 50-287/87-03 on 870112-16.Violation Noted:Failure to Adequately Evaluate Radiological Hazards ML20210U3211987-02-0505 February 1987 Notice of Violation from Insp on 861015-1110.Violation Noted:For Periods in 1978,1981 & 1986 When Lake Keowee Elevation Less than 792 Ft,Emergency Condenser Cooling Water Sys Inoperable & Unable to Provide Sustained Siphon Flow IR 05000269/19870071987-02-0505 February 1987 Enforcement Conference Repts 50-269/87-07,50-270/87-07 & 50-287/87-07 on 861222.Major Areas Discussed:Sequence of Events & Corrective Actions Re Emergency Condenser Circulating Water Sys Degradation IR 05000269/19870081987-02-0505 February 1987 Enforcement Conference Repts 50-269/87-08,50-270/87-08 & 50-287/87-08 on 861222.Major Areas Discussed:Safety Sys Functional Insp & Associated Safety Implications IR 05000269/19860341987-02-0505 February 1987 Corrected Insp Repts 50-269/86-34,50-270/86-34 & 50-287/86-34 on 861111-870112.Insp Erroneously Reported as Having Been Conducted on 861111-0112 ML20211A0871987-02-0303 February 1987 Notice of Violation from Insp on 870105-08 IR 05000269/19870011987-01-30030 January 1987 Insp Repts 50-269/87-01,50-270/87-01 & 50-287/87-01 on 870105-08.Violation Noted:Failure to Provide Procedures W/Appropriate Qualitative or Quantitative Acceptance Criteria for Activities Important to Safety ML20211A0061987-01-23023 January 1987 Insp Repts 50-269/86-34,50-270/86-34 & 50-287/86-34 on 861111-870112.No Violations or Deviations Noted.Major Areas Inspected:Operations,Surveillance,Maint,Verification of ESF Lineups & Emergency Drills ML20210U9961987-01-22022 January 1987 Exam Rept 50-269/OL-86-03 on 861215.Exam Results:Two Reactor Operator Candidates Passed Written Reexam.Written Exam Questions & Answer Key Encl IR 05000269/19860351987-01-0707 January 1987 Insp Repts 50-269/86-35,50-270/86-35 & 50-287/86-35 on 861208-12.No Violations or Deviations Noted.Major Areas Inspected:Radiation Protection Program,Including Review of Organization & Mgt of Health Physics Staff ML20212F5511986-12-24024 December 1986 Notice of Violation from Insp on 861103-12 PNO-II-86-092, on 861218,licensee Shut Down Unit to Begin Scheduled Refueling Outage 6 Wks Early.Caused by Excessive Vibrations in Reactor Coolant Pump 3B2.During Outage,Reactor Coolant Pumps 3B1,3B2 & 3A1 Will Be Modified1986-12-18018 December 1986 PNO-II-86-092:on 861218,licensee Shut Down Unit to Begin Scheduled Refueling Outage 6 Wks Early.Caused by Excessive Vibrations in Reactor Coolant Pump 3B2.During Outage,Reactor Coolant Pumps 3B1,3B2 & 3A1 Will Be Modified IR 05000269/19860321986-12-10010 December 1986 Insp Repts 50-413/86-44,50-414/86-47,50-369/86-32, 50-370/86-32,50-269/86-32,50-270/86-32 & 50-287/86-32 on 861103-12.Violations Noted:Failure to Follow Procedures for Radiological Sample Analyses & Inadequate Surveys IR 05000269/19860281986-11-0303 November 1986 Partially Withheld Physical Security Insp Repts 50-269/86-28,50-270/86-28 & 50-287/86-28 on 861014-17 (Ref 10CFR2.790 & 73.21).Violation Noted:Inadequate Protected Area Barrier 1997-09-26
[Table view] |
See also: IR 05000269/1986005
Text
_ . _ . . .
,
, $ narco URITED STATES
-
o NUCLEAR REGULATORY COMMISSION
"
, REGloN 11
[' n
g j 101 MARIETTA STRE ET.N.W.
- 'c ATLANTA, GEORGI A 30323
%,
/ '
.
fM 2 7 T.i36
Report Nos.: 50-269/86-05, 50-270/86-05 and 50-287/86-05
Licensee: Duke Power Company
422 South Church Street
Charlotte,.NC 28242
Docket Nos.: 50-269, 50-270, and 50-287 License Nos.: DPR-38, DPR-47, and
DPR-55
Facility Name: Oconee
Inspection Conducted: February 24-28, 1986
Inspector :
T. R. Colli s
M8
_[ Tate S'igned
Approved by:
C. M. Hosdy, Sect ~ on Chief
J/27h//
Dats S;gn'ed
Emergency Prepardtess and Radiological
Protection Branch
Division of Radiation Safety and Safeguards
SUMMARY
Scope: This routine, unannounced inspection involved 36 inspector-hours on site
during normal hours, inspecting the radiation protection program including
training and qualification of personnel, internal and external exposure control,
radioactive material control, posting and labeling, and the program for
maintaining exposure as low as reasonably achievable (ALARA).
Results: One violation was identified in the area of failure to provide adequate
respiratory protective equipment to maintain intakes of radioactive material as
low as reasonably achievable.
I
O
_. .
g -
p(
,
e
. .
p -
2
. REPORT DETAILS
1. Persons Contacted
' Licensee Employees
- M. S. Tuckman, Station Manager
- T. S. Barr, Superintendant of Technical Services
- C. T. Yongue, Station Health Physicist
- E. Brown, Health Physics Supervisor
- M. Thorne, Health Physics Supervisor
- T. C. Matthews. Compliance Technical Specialist
J. Owens, Health Pnysics Supervisor
T. Cherry, ALARA Coordinator
- S. Spears, Health Physics Coordinator
C. Harlin, Health Physics Coordinator
L. Garrett, ETQS Coordinator
B. Earnhart, Outage and Planning Coordinator
Other licensee employees contacted included four construction craftsmen,
five. technicians, two operators, three' mechanics, three security force
members, and.two office personnel.
Other Organizations
RAD Services, Inc.
NRC Resident-Inspectors
- J. Bryant, Senior Resident Inspector
- K. Sasser, Resident Inspector
2. Exit. Interview
The inspection scope and findings were summarized on February 28, 1986, with
those . persons indicated in paragraph 1 above. The inspector discussed the
apparent violation for not providing adequate respiratory protection to
individuals while working in Unit #3 Containment on March 29, 1985. See
report details paragraph 9.
The licensee did not identify as proprietary any of the materials provided
to or reviewed by the inspector during tnis inspection.
3. Licensee Action on Previous Enforcement Matters
(Closed) Unresolved Item 50-269, 270, and 267/85-42-02. Provide air sample
results to assure adequate evaluation of airborne radioactive material. The
w
,
. ~.
. .
.
3
inspector reviewed air sample results as provided by the licensee and
concluded that the licensee did evaluate and document air sample results to
evaluate the radiation hazards present to assure personnel did not exceed 40
MPC-hrs.
(Closed) Unresolved Item 50-269, 270 and 287/85-42-03. Provide air sample
data to evaluate airborne radioactivity in Unit #3 Containment. The
inspection reviewed air sample results of Unit #3 Containment as provided by
the licensee and concluded that the licensee had taken an adequate air
sample to evaluate the air concentrations in Unit #3 Containment.
4. Training and Qualifications (83723)
a. Basic Radiation Protection Training
The licensee was required by 10 CFR 19.12 to provide basic radiation
protection training to workers. Regulatory Guides 8.27, 8.29, and
8.13, outline topics that should be included in such training. .
Chapters 12 and 13 of the FSAR contain further commitments regarding
training. During tours of the plant, the inspector discussed topics
from the GET training with a maintenance mechanic to determine the
"
effectiveness of the training. The inspector selectively reviewed the
GET training records fcr workers to determine if records reflected
adequate completion of GET initial and refresher training.
b. Radiation Protection and Chemistry Technician Qualification
'The inspector reviewed the program for qualifiction of contract
radiation protection technicians. The inspector discussed separately
with three contract technicians their previous experience and training
to determine if it was comprehensive or if it had been limited to
selected tasks. The inspector also discussed the training and
qualification program the licensee had provided, what limits had been
placed on their activities, and controls that should be established for
one task they were qualified to perform. The inspector reviewed the
resumes, training records, and tests for these technicians. -
c. Respiratory Protection Training
The licensee was required by 10 CFR 20.103 to establish a qualification
program for workers who wear respiratory protective equipment.
Elements of the qualification program outlined in 10 CFR 20.103 we are
-
delineated in NUREG-0041. The inspector observed workers using
respirators while they were performing maintenance in the auxiliary
building. The inspectors discussed this use with the radiation
protection technician covering the job and with the workers. The
inspector reviewed the workers' respirator qualification reccrds. The
inspector reviewed recent changes in the respirator qualification
program and discussed these changes with the training supervisor.
.
No violations or deviations were identified.
-- . ___ _. _. _ _ . _ _ _ _ _ _ _ _ _ _ - _ _ _
e
. ~.
.
4
d. Technical Specification 6.1 specified minimum plant staffing. FSAR
Chapters 12 and 13 also outlined further details on staffing. The
inspector discussed authorized staffing levels and actual on-board
- staffing separately with the Station Health Physicist- and Station
Manager. The inspector exarr.ined shift staffing for the midnight shift
on February 25, 1986, to determine if it met minimum criteria fc
radiation protection.
No violations or deviations were identified.
5. Control of Radioactive Materials and Contamination, Surveys, and Monitoring
(83726)
The licensee was required by 10 CCR 20.201(b) and 20.401 to perform surveys
to show compliance with regulatory limits and to maintain records of such
surveys. Chapter 12 of the FSAR further outlines survey methods and
instrumentation. Technical Specification 6.8 required the licensee to
follow written procedures. Radiological control procedures further outlined
survey methods and frequencies.
a. The inspector observed, during plant tours, surveyt being performed by
radiation protection staff. The inspector reviewed selected radiation
work permits, to determine if adequate controls were specified. The
inspector discussed the controls and monitoring with the radiation
protection technician assigned.
During plant tours, the inspector observed radiation level and
contamination survey results outside selected cubicles. The inspector
performed independent radiation surveys of selected areas and compared
them to licensee survey results. The inspector reviewed selected
survey records for the month of February 1986 and discussed with
licensee representatives methods used to disseminate st.rvey results.
The inspector noted that there were several locked high radiation areas
outside containment,
b. Frisking
During tours of the plant, the inspector observed the exit of workers
and movement of material from contamination control areas to clean
~
areas to determine if proper frisking was performed by workers and that
proper direct and removable contamination surveys were performed on
materials. The inspector reviewed records of skin contamination
occurrences and resulting evaluations and corrective actions. Records
and discussions with licensee representatives showed contamination had
been promptly removed from the workers using routine washing
techniques. Subsequent whole body counts showed less than detectable
internal deposition of radioactive material.
-- -
7 _
c .
.
5
c. Instrumentation
During plant tours, the inspector observed the use of survey instru-
ments by plant staff and compared plant survey meter results with
results .of surveys made by the inspector using NRC equipment. The
inspector examined calibration stickers on radiation protection
instruments in use by licensee staff and stored in the radiation
protection laboratory. The inspector discussed with radiation
protection technicians the methods for doing instrument source checks
prior to each use and calibration methods. The inspector reviewed the
procedures and methods for calibration of survey instruments and
friskers.
d. Release of Materials for Unrertricted Use
The inspector discussed, with a radiation protection technician, the
program _ for survey-out of items from contaminated areas and reviewed
the procedures for such release. The inspector observed release
surveys performed by radiation protection technicians, and documen-
tation of results. The inspector performed confirmatory direct and
removable contamination surveys on items released. During tours of
plant areas, the inspector observed posting of containers and performed
indepencent surveys to determine if containers of radioactive material
were properly' identified.
No violations or deviations were identift.ed.
6. Facilities and Equipment (83727)
FSAR Chapters 1 and 12 specified plant i yout and radiation protection
facilities and equipment. During plant tours, the inspector observed the
operation of the contaminated clothing laundry, the flow of traffic thru
change rooms, the use of temporary shielding and the use of glove bags, and
ventilated containment enclosures.
No violations or deviations were identified.
7. External Occupational Dose Control and Personal Dosimetry (83724)
During plant tours, the inspector checked the security of the locks at
several locked high radiatior, areas and observed posting of survey results
,
and the use of controls specified on six radiation work permits (RWPs),
a. Use of Dosimeters and Controls .
The licensee was required by 10 CFR 20.202, 20.201(b), 20.102, 20.102,
20.104, 20.402, 20.403, 20.405, 19.13, 20.407, 20.408 to maintain
workers's doses below specified levels and keep records of and make
reports of doses. The licensee was required by 10 CFR 20.203 to post
and control access to plant areas. FSAR Chapter 12 also contained
commitments regarding dosimetry and dose controls. During observation
n
. *s
.
6
of work in the plant, the inspector observed the wearing of TLDs and
pocket dosimeters by workers. The inspector discussed the assignment
~
and use of- dosimeters with maintenance mechanics and radiation
protection technicians. During plant tours, the inspector observed the
-posting of areas and made independent measurements of dose to assure
proper posting. The inspector reviewed recent changes to plant pro-
cedures regarding the use of TLDs and dosimeters.
b. Processing of Dosimeters
The inspector discussed with the Dosimetry Supervisor the flow of the
TLD badge from its return by a worker thru the recording of information
(dose) from the readout on the worker's dose record, to determine areas
where information could r,ssibly be mishandled. The inspector
discussed, with an assigned radiation protection technician, the system
for comparison of TLD and pocket dosimeter results. The inspector
reviewed the records of pocket dosimeter drift and calibration checks
for the year of 1935.
c. Dosimetry Results
The inspector reviewed the TLD results for 1985 and for the first
quarter of 1986. The inspector selectively examined individuals'
.
dosimetry files to determine if NRC Form 4's had been completed. The
inspector selectively reviewed the results of the TLD vs. pocket
chamber comparisons for the year of 1985.
d. Management Review of Dosimetry Results
The inspector discussed the dosimetry results with a Health Physic's
Supervisor, concentratirg on their assigned staff to determine their
'
understanding of dosimetry results for their staff. The inspector
reviewed records of administrative doso control extensions for the year
1985 and discussed the extensions with selected supervisors and staff.
The inspector reviewed records of cases where workers exceeded
administrative controls without dose extensions. The inspector
discussed these cases with selected involved individuals and reviewed
corrective actions.
No violations or deviations were identified.
9. Internal Exposure Control and Assessment (83725)
The licensee was required by 10 CFR 20.103, 20,201(b), 20.401, 20.403, and
20.405 to control uptakes of radioactive material, assess such uptakes, and
keep records of and make reports of such uptakes. FSAR Chapter 12 also
includes commitments regarding internal exposure control and assessment.
,-
'
p . A
.
7
a. Control Measures
During plant tours, the inspector observed the use of temporary
ventilation systems, containment enclosures, and respirators. The
-inspector discussed the use of this equipment with workers and radia-
"
tion protection technicians.
b. Respiratory Maintenance and Issue
The inspector observed the issuance of respirators and reviewed records
for several workers who were issued respirators to determine if they
were qualified for the respirators issued. The inspector reviewed
recent changes to respirator maintenance and issue procedures,
c. Respirator Fit Testing and Training
The inspector discussed fit testing with Health Physics personnel. The
inspector reviewed recent changes to procedures regarding fit testing
and training. The inspector discussed respiratory protection training
with workers,
d. Uptake Assessment
The inspector observed operation of whole body counter and discussed
its operation and results with the counter operator. The inspector
reviewed the results of the analyses performed for selected individuals
for 1985. The inspector discussed the assessments and corrective
actions with Health Physics personnel. The inspector reviewed the
Maximum Permissible Concentration-hour (MPC-hour) log for selected
periods of 1985 and discussed the actions taken by the licensee for
personnel that received greater than 2 MPC-hours in a day and 10
MPC-hours in a week.
The inspector reviewed the MPC hour logs for 1985 and noted there were
no personnel listed with greate. than 40 MPC-hours during a week.
However, the inspector noted an event which occurred on March 29, 1985,
where workers were allowed to enter Unit #3 Containment to perform
associated duties during reactor start-up. During this period high
concentrations of Iodine-131 were present, up to approximately 20 times
the Maximum Permissible Concentrations (MPCs) set forth in 10 CFR 20
Appendix B. The licensee permitted these personnel to enter
containment without adequate respiratory equipment which resulted in
the individuals receiving uptakes of radioactive material ranging from
1.5% maximum permissible organ burden (MPOB) to 6.5% MPB0 Iodine-131.
10 CFR 20.103(b)(2) requires in part that respiratory protective
equipment be used to limit the intake of radioactive material to as low
as is reasonably achievable. The licensee stated that they decided not
to provide respirators equipped with iodine removal canisters to these
l personnel because the shelf life on the canisters had expired and that
- they felt the job could be performed faster and safer without
.. . - _ . _ _ . -
..
_
,
. .
,
k
8
-
-
respiratory equipment. Failure to maintain intakes of radioactive
-
material as low as is reasonably achievable was identified as an
apparent violation of 10 CFR 20.103(b)(2) (50-269,270, and
287/86-05-01).
10. Maintaining Occupational Doses ALARA (83726)
{
10 CFR 20.1(c) specifies that licensees should implement programs to keep
- workers' doses ALARA. FSAR Chapter 12 also contains licensee commitmentt
regarding worker ALARA actions.
_
a. Worker and Supervisor Actions
The inspector discussed with ALARA personnel their actions to reduce
individual and collective doses, concentrating particularly on staff
'
members with highest doses. The inspector also discussed these actions
to set dose goals for tasks, methods used to reduce dqses, and
techniques used to monitor performance against goals.
--
. b. ALARA Procedure Changes
The inspector reviewed recent changes to administrative procedures that
L implemented the elements of ALARA. The inspector discussed these
enanges with the ALARA' Coordinator.
c
c. ALARA Reviews
- The inspector reviewed the ALARA review documentation for selected
"
activities during 1985 and discussed resulting actions with the ALARA
_
Coordinator.
--
d. ALARA Reports
The inspector reviewed selected ALARA Reports for 1985 and the 1985
-
_
ALARA summary report and discussed the results with the ALARA Coordi-
natory and Station Health Physicist. The summary of tasks estimate for
1985 was 1093 man-rems. The total cumulative dose for 1985 was 1303
man-rems. The outage estimate for 1986 was 395 man-rems. Through
February 24, 1986, the total was 176 man-rem.
No violations or deviations were identi'~ed.
_
11. Problem Reports and Radiological Deficier :y Reports.
-
The inspector selectively examined the Problem Reports and Radiological
_
Deficiency Reports and resulting corrective actions for the period January
-
-
through June 1985.
No violations or deviations were identified.
K
_
E
5
EL
r
- L .
.. .
~ ~~ ' " ' " ~
9 ,
l
- y ,
,
'12. Preparation for Mardh 1986 Outage
-a. Work Packages
The inspector discussed the preparations for the February 1985 outage
with the Outage Coordinator, ALARA Coordinator, and the Station Health
Physicist. The inspector reviewed the task list for the outage.
b. Radiation Protection and Chemistry Staffing
-The inspector discussed with the Station Manager and the Statica Health
Physicist, the plans for supplemental staffing, including decon,
shielding, and laundry staff, during the outage and subsequent startup.
The inspector. discussed methods to be. used to select and qualify the
staff with contractor support, proposed metheds of supervision and
limitations on task assignments.
Na violations or deviations were identified.
.