NEXTera EN ERGY ~

POINT BEACH July 15, 2014 NRC 2014-0049 10 CFR 50.55a U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Point Beach Nuclear Plant, Unit 2 Docket 50-301 Renewed License No. DPR-27 Filing of Owner's lnservice Inspection Summary Report IWE Class MC and IWL Class CC for Point Beach Nuclear Plant Refueling Outage U2R33 NextEra Energy Point Beach, LLC (NextEra) is submitting the inservice inspection summary report for inspections conducted prior to and during the Point Beach Nuclear Plant (PBNP) refueling outage U2R33 that concluded on Apri118, 2014. The enclosed IWE Class MC and IWL Class CC report is submitted pursuant to the requirements of Subarticle IWA-6240 of the 2001 Edition with Addenda through 2003 of Section XI of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code and ASM E Code Case N-532-4. to this letter contains the summary report, which includes completed Form OAR-1, "Owner's Activity Report" for inservice inspections for the Class MC and CC components . The report is for the first outage of the Third Period of the Second 10-year Interval for Class MC and CC at PBNP Unit 2.

Very truly yours, NextEra Energy Point Beach, LLC Michael Millen Licensing Manager Enclosures cc: Administrator, Region Ill, USNRC Project Manager, Point Beach Nuclear Plant, USNRC Resident Inspector, Point Beach Nuclear Plant, USNRC PSCW Mike Verhagen, State of Wisconsin NextEra Energy Point Beach, LLC, 66 10 Nuclear Road, Two Rivers, WI 54241

FORM OAR-I OWNER'S ACTIVITY REPORT Report Number _ _ _ _ __,U"'-2""R~33~0~u"'ta,.g,e'-'C"'I'-"a""ss,_M,_,_,_,C"--"'m'-"1d,__,C,C'-'I'-'S'-"I--"E"-'x"'a"'m"-'i-'-'n"'at,.,io~n_,___ _ __ _ _ __ _ _ __ _ _ __ _ _ _ _ __

Plant NextEra Energy Point Beach Nuclear Plant, 6610 Nuclear Road, Two Rivers, Wisconsin 54241 Unit No. 2 Commercial Service Date ---'0"'-c"-'t,.ob""e"'"r--'1""-9-'-'72"--------- Refueling Outage No. ------"'U=2R==33"-------

(If applicable)

Current Inspection Interval Second (I st, 2nd, 3rd, 4th, other)

Current Inspection Period Third (I st, 2nd, 3rd)

Edition and Addenda of Section X1 applicable to the inspection plans 200 I Edition 2003 Addenda Date and Revision of inspection plans Class MC: January 19, 2013 I Revision 4. Class CC: June II. 2010 I Revision 2 Edition and Addenda of Section XI applicable to repairs/replacements activities, if different than the inspection plans "'S"'ai"'n"'e_ __ _ _ _ __

Code Cases used: N-532-4 N-739 N-753 (If applicable)

CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are conect; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repair/replacement activities and evaluations supporting the completion of _ _ __ _ ___,U"-'2"'R'""3"'3"----- - - -- -

(refueling outage number) conform to the requirements of Section XI.

Signed _ __

~r's

/---'A~~="7-- --=-----=-, - -. .,.- ,-,- - 'IW-'-'-'E"'!I"-W-'-'-=L'-'P'- 'I~*o:cgi'-"a'.,m"- "'O"'w'-"n" e'- r_Date _ _ .)!.OC!.7"-'-0'-'7.::.-I'-'4r__

Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSB Global Standards have inspected the items described in this Owner's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluations described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

\

---,ONT'A.-'-u}£~~

(J

-~

"~-=--....:::._ _~-"-"-'L~_'______ ___

(¥ftillign;liUfe Commissions WI 929625 A,I,N National Board, State, Province, and Endorsements

Table 2 Abstract of Repair/Replacement Activities Requ ired for Continued Service Repair/

Replacement Date Plan Code Class Item Description Description of Work Completed Number None None None None None