ML24214A049

From kanterella
Jump to navigation Jump to search
Enclosure 7: ENG-OCS-002 Revision 1, RESRAD-Build Input Parameter Sensitivity Analysis - Ocs, March 6, 2024
ML24214A049
Person / Time
Site: Oyster Creek
(DPR-016)
Issue date: 03/06/2024
From: Bisson J
BHI Energy I Power Services, Holtec Decommissioning International
To:
Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation
Shared Package
ML24214A209 List:
References
HDI-OC-24-018 ENG-OCS-002, Rev 1
Download: ML24214A049 (1)


Text

BHI ENERGY ENGINEERING CALCULATION RESRAD-Build Input Parameter Sensitivity Analysis - OCS ENG-OCS-002 Revision: 1 March 6, 2024 Prepared by:

BHI Energy l Power Services 97 Libbey Industrial Pkwy Weymouth, MA Prepared by Approved by

BHI Engineering ENG-OCS-002 RESRAD-Build Input Parameter Sensitivity Analysis-OCS Rev. 1 Page 1 of 24 1.0 PURPOSE This calculation identifies sensitive input parameters (i.e., those input parameters that produce a significant change in the calculated dose with changes in their value) in the evaluation of the building occupancy scenario using the RESRAD-Build code (version 3.5). Identification of sensitive input parameters is a necessary process to account for uncertainty in input values. The uncertainty associated with sensitive input parameters is addressed in subsequent DCGL calculations by determining and assigning reasonably conservative input values from the results of RESRAD-Build probabilistic analyses. Thus, the results of this calculation support the development of building surface derived concentration guideline levels (DCGLs) for the Oyster Creek Station (OCS) site.

2.0 APPLICABILITY This calculation addresses only the sensitivity analysis for input parameters for the building occupancy scenario as defined for the OCS site.

3.0 REFERENCES

3.1 BHI Energy Engineering Procedure ENG-AP-02, Verification of Software Operability 3.2 Users Manual for RESRAD-Build Version 3.0, June 2003 (ANL/EAD/03-1) 3.3 NUREG/CR-7267, Default Parameter Values and Distribution in RESRAD-ONSITE V7.2, RESRAD-BUILD V3.5, and RESRAD-OFFSITE V4.0 Computer Codes, February 2020 3.4 NUREG/CR-5512, Residual Radioactive Contamination from Decommissioning 3.4.1 Volume 1: Technical Basis for Translating Contamination Levels to Annual Total Effective Dose Equivalent, Oct. 1992 (PNL-7994) 3.4.2 Volume 3, Residual Radioactive Contamination from Decommissioning:

Parameter Analysis, Draft Report for Comment, October 1999 3.5 NUREG/CR-6697, Development of Probabilistic RESRAD 6.0 and RESRAD-Build 3.0 Computer Codes, November 2000 3.6 NUREG/CR-6755, Technical Basis for Calculating Radiation Doses for the Building Occupancy Scenario Using the Probabilistic RESRAD-Build 3.0 Code, February 2002 (ANL/EAD/TM/02-1) 3.7 Radionuclide Selection for DCGL Development - Oyster Creek Station Site Characterization Project, January 2022 3.8 NUREG/CR-6676, Probabilistic Dose Analysis Using Parameter Distributions Developed for RESRAD and RESRAD-BUILD Codes, May 2000 4.0 METHOD OF CALCULATION The operability of the RESRAD-Build code version 3.5 was verified on each computer use for code executions in accordance with the BHI Energy Engineering procedure ENG-AP-02, Verification of Software Operability [3.1]. The RESRAD-Build Users Manual [3.2] provided guidance for code operation.

The sensitivity analysis for RESRAD-Build input parameters was performed using Version 3.5 of the RESRAD-Build computer code, which was developed by Argonne National Laboratory under the sponsorship of the U.S. Department of Energy and other federal agencies. The probabilistic modules in RESRAD-Build permit the user to identify input parameters that have a significant impact on dose with

BHI Engineering ENG-OCS-002 RESRAD-Build Input Parameter Sensitivity Analysis-OCS Rev. 1 Page 2 of 55 changes in input values. Verification of the RESRAD-Build code is documented in the RESRAD-Build Users Manual and testing for the probabilistic codes is discussed in NUREG/CR-7267 [3.3].

The exposure scenario modeled in this calculation is the building occupancy scenario, which provides estimates of human radiation exposures to residual radioactivity on surfaces inside standing buildings and permits the determination of DCGLs for building surfaces. The exposure pathways considered are:

direct external exposure from the source (i.e., radioactive material deposited on the floor, walls, and ceiling),

external exposure from deposited material, external exposure due to air submersion, exposure due to inhalation of airborne radioactive material, and ingestion of radioactive material directly from the sources and material deposited on the surfaces.

Input parameters were treated as either deterministic (a single value is assigned) or stochastic (a probability distribution is assigned). Treatment depended on parameter type, availability of site-specific data, and the relevance of the parameter in the dose calculations.

Behavioral and metabolic parameters were treated as deterministic, and the assigned values were from NUREG/CR-5512, volume 3 [3.4.2], NUREG/CR-7267, or the RESRAD-Build Users Manual. Parameters for which site-specific data are available were treated as deterministic.

Physical parameters for which site-specific data are unavailable were assigned values based on priority. Priority 1 and 2 physical parameters were treated stochastic and assigned probability distributions from NREG/CR-5512, volume 3, NUREG/CR-7267, NUREG/CR-6755 [3.6], or assigned a deterministic value from NUREG/CR-5512, volume 3, NUREG/CR-7267, or NUREG/CR-6755. Priority 1 and 2 physical parameters for which site-specific data are available were treated as deterministic. Priority 3 physical parameters were treated as deterministic and were assigned values from NUREG/CR-5512, volume 3, NUREG/CR-7267, NUREG/CR-6755, or the RESRAD-Build Users Manual.

RESRAD-Build parameter sensitivity analysis was performed for each radionuclide-of-concern (ROC).

The RESRAD-Build Probabilistic Output Report provides regression and correlation coefficients for the average doses at the user defined evaluation times. The Partial Rank Correlation Coefficient (PRCC) has been used to identify sensitive parameters. NUREG/CR-7267 and NUREG/CR-6697 recommend the use of the PRCC for cases where non-linear relationships exist. PRCC values greater than zero (positive value) or less than zero (negative value) identify whether sensitive parameters are positively or negatively correlated to dose, respectively.

The criterion for sensitivity used in this calculation was a PRCC value with an absolute value equal to or greater than 0.1. To address the uncertainties associated with the input parameters identified as sensitive, the 25th percentile value of the parameters distribution was selected for sensitive parameters that had a negative PRCC value, and the 75th percentile value of the parameters distribution was selected for sensitive parameters that had a positive PRCC value. The 75th percentile and 25th percentile values are recommended as reasonably conservative input values for calculations of DCGL values for buildings/structures at the OCS site. The approach of assigning 25th and 75th percentile values of a sensitive parameters distribution has been found acceptable as a reasonably conservative approach by the U.S. Nuclear Regulatory Commission (NRC) and State regulators.

5.0 ASSUMPTIONS AND INPUT

BHI Engineering ENG-OCS-002 RESRAD-Build Input Parameter Sensitivity Analysis-OCS Rev. 1 Page 3 of 55 5.1 Assumptions 5.1.1 Building Scenario description: The RESRAD-Build code v3.5 was used to model (through use of input parameter values) the building occupancy scenario defined in NUREG/CR-5512, volume 1 [3.4.2]. Five exposure pathways are assumed active: (i) direct external exposure from the source (i.e., radioactive material deposited on the floor, walls, and ceiling), (ii) external exposure from deposited material, (iii) external exposure due to air submersion, (iv) exposure due to inhalation of airborne radioactive material, and (v) ingestion of radioactive material directly from the sources and material deposited on the surfaces.

5.1.2 Site-specific suite of ROCs has been identified for the OCS site [3.7]. The OCS ROCs (and their progeny where applicable) are shown in Table 1 below.

Table 1. Radionuclide Input for RESRAD-Build ROCa Progenyb ROCa Progenyb Am-241 Np-237, Th-229, U-233 Nb-94 C-14 Ni-63 Cm-243 Ac-227, Pa-231, Pu-239, U-235 Np-237 Th-229, U-233 Cm-244 Pu-240, Ra-228, Th-228, Th-232, U-236 Pu-238 Pb-210, Po-210, Ra-226, Th-230, U-234 Cs-137 Pu-239 Ac-227, Pa-231, U-235 Co-60 Pu-240 Ra-228, Th-228, Th-232, U-236 Eu-152 Gd-152 Pu-241 Am-241, Np-237, Th-229, U-233 Eu-154 Sb-125 Te-125m Fe-55 Sr-90 H-3 Tc-99 Mn-54 a ROC identified for the OCS site [3.7].

b Progeny radionuclides automatically included by RESRAD-Build software with ROC input.

5.1.3 The hypothetical worker is assumed to perform activities inside an office room for a full occupational year; 45 hours5.208333e-4 days <br />0.0125 hours <br />7.440476e-5 weeks <br />1.71225e-5 months <br /> per week for 52 weeks.

5.1.4 The representative room modeled for the OCS site is based on the room described for the occupancy scenario in Volume 1 of NUREG/CR-5512 and in NUREG/CR-6755

[3.6]: an 8m by 8m room with 3m walls. This room includes 6 area sources (i.e. floor, 4 walls, and ceiling).

5.2 Input Table 2 summarizes the classification, prioritization, values, and their bases for all input parameters.

Values from NUREG/CR-5512, volume 3, and NUEG/CR-7267, NUREG/CR-6755, were assigned for the following scenario-defined parameters:

Exposure duration: 365.25 d

BHI Engineering ENG-OCS-002 RESRAD-Build Input Parameter Sensitivity Analysis-OCS Rev. 1 Page 4 of 55 Indoor fraction: 0.267 Inhalation rate: 33.6 m3/d Receptor location (center of room, x, y, z coordinates): 4m, 4m, 1.0m Air fraction: 1.0 for H-3 (triangular distribution used for all other nuclides)

Removable fraction: 0.1 (all ROCs)

Room area: 64 m2 Room height: 3 m Receptor location: center Location of center of source: center point of floor, walls, and ceiling Statistical distributions from NUREG/CR-7267 and NUREG/CR-6755 provided input for:

deposition velocity, air exchange rate for room, re-suspension rate, indirect ingestion rate, air release fraction, and time for source removal.

An input correlation of 0.9 between the deposition velocity and the resuspension rate was applied based on guidance in NUREG/CR-6676 [3.8]. In addition, because the sources are assumed constructed of the same material and subject to the same environment, an input correlation of 0.9 was applied for the time for source removal between sources.

6.0 CALCULATIONS AND RESULTS 6.1 Room dimensions: dimensions of a representative room are 8m by 8m by 3m.

6.2 Direct ingestion rate (h-1) is based on the direct ingestion rate given in NUREG/CR-6755:

4.91E-07 h-1.

6.3 Using the dimensions for the modelled room, the locations of the centers of the sources were determined as the mid-point on the X, Y, and Z-axes.

Source No.

Source Description Location of Center of Source (m)

X-axis Y-axis Z-axis 1

Floor 4

4 0

2 Wall 1 4

0 1.5 3

Wall 2 0

4 1.5 4

Wall 3 4

8 1.5 5

Wall 4 8

4 1.5 6

Ceiling 4

4 3

6.4 RESRAD-Build v3.5 results: Table 2 summarizes the input used in RESRAD-Build code executions. Appendix A provides copies of selected pages from the RESRAD-Build uncertainty reports.

6.4.1 Each ROC listed in Table 1 was evaluated in separate code executions.

BHI Engineering ENG-OCS-002 RESRAD-Build Input Parameter Sensitivity Analysis-OCS Rev. 1 Page 5 of 55 6.5 PRCC values were reviewed against the sensitivity criterion (i.e., PRCC0.1). The building air exchange rate, and the air release fraction were identified as sensitive input parameters for all ROCs. Table 3 summarizes the sensitive parameters by radionuclide.

NOTE In DCGL calculations, 25th or 75th percentile values will be input values for ROCs for which one of the above-listed parameters was identified as sensitive. The 50th percentile value will be used as input if a parameter is not identified as sensitive.

6.6 The 25th, 50th, and 75th percentile values are obtained from the RESRAD-Build probabilistic results. Table 4 presents these values.

7.0 CONCLUSION

7.1 The building air exchange rate, deposition velocity, resuspension rate, ingestion rate, time of source removal, and the air release fraction are sensitive parameters for one or more of the ROCs in the modelling of the building occupancy scenario using RESRAD-Build.

7.2 The building air exchange rate (LAMDAT), deposition velocity (UD), resuspension rate (DKSUS), and ingestion rate (INGE) characterize the room. The uncertainty in the input values for each of these parameters will be considered in DCGL calculations by applying the 25th or 75th percentile value to all 6 sources if a parameter was identified as sensitive for any one of the 6 sources.

7.3 The source removal time (RFO) and air fraction (AIRFR) characterize the source. Use of the 25th and 75th percentile values will provide conservative input in DCGL calculations to consider the uncertainty associated with input for sensitive parameters.

BHI Engineering ENG-OCS-002 RESRAD-Build Input Parameter Sensitivity Analysis-OCS Rev. 1 Page 6 of 24 Table 2. Values for RESRAD-Build Parameters RESRAD-BUILD Input Parameter Values for Sensitivity Analysis Building Occupancy Scenario Parameter Type Priority Treatment Value or Distribution Value/Distribution Reference Source Distribution's Statistical Parametersa 1

2 3

4 Exposure Duration (d)

B 3

D 365.25 NUREG/CR-5512, NUREG/CR-7267 Indoor Fraction B

2 D

0.267 NUREG/CR-5512, NUREG/CR-7267 Evaluation Time (y)

P 3

D 1 or multiple (e.g., 1, 5, 10, 50)

T=1 corresponds to dose over the 1st year Number of Rooms P

3 D

1 NUREG/CR-5512 building occupancy scenario assumes one contaminated room Deposition Velocity (m/s)

P 2

S Loguniform NUREG/CR-6755, NUREG/CR-7267 2.7E-06 2.7E-03 Resuspension Rate (s-1)

P 1

S Loguniform NUREG/CR-6755, NUREG/CR-7267 2.5E-11 1.3E-5 Air Exchange Rate for Room (h-1)

B 2

S Truncated Lognormal NUREG/CR-6755 0.4187 0.88 0.001 0.999 Room Area (m2)

P 2

S 64 NUREG/CR-6755 Room Height (m)

P 2

D 3

NUREG/CR-6755 Time Fraction B

3 D

1 Defined as most conservative value in NUREG/CR-7267 Inhalation Rate (m3/d)

M 2

D 33.6 NUREG/CR-5512 Indirect Ingestion Rate (m2/h)

B 2

S Loguniform NUREG/CR-6755, NUREG/CR-7267 2.8E-5 2.9E-4 Receptor Location x, y, z (m)

B 3

D 4, 4,1 Center of room based on scenario room dimensions defined in NUREG/CR-5512 and NUREG/CR-7267 Shielding Thickness (cm)

P 2

D 0

No shielding assumed

BHI Engineering ENG-OCS-002 RESRAD-Build Input Parameter Sensitivity Analysis-OCS Rev. 1 Page 7 of 24 RESRAD-BUILD Input Parameter Values for Sensitivity Analysis Building Occupancy Scenario Parameter Type Priority Treatment Value or Distribution Value/Distribution Reference Source Distribution's Statistical Parametersa 1

2 3

4 Shielding Density (g/cm3)

P 1

D 1

Input value required by code execution - input has no impact due to shielding thickness input Shielding Material P

3 D

water Input value required by code execution - input has no impact due to shielding thickness input Number of Sources P

3 D

6 Includes floor, ceiling and 4 walls consistent to scenario assumptions stated in NUREG/CR-7267 External Dose Conversion Factor, (mrem/y per pCi/cm2)

M 3

D RESRAD-Build Dose Conversion Factor Library Values were from Federal Guidance Report No.12 (FGR-12).

Air Submersion Dose Conversion Factor, (mrem/y per pCi/m3)

M 3

D RESRAD-Build Dose Conversion Factor Library Values were from Federal Guidance Report No.12 (FGR-12).

Inhalation Dose Conversion Factor, (mrem/pCi)

M 3

D RESRAD-Build Dose Conversion Factor Library Values were from Federal Guidance Report No.11 (FGR-11).

Ingestion Dose Conversion Factor, (mrem/pCi)

M 3

D RESRAD-Build Dose Conversion Factor Library Values were from Federal Guidance Report No.11 (FGR-11).

Source 1: Floor Type P

3 D

area NUREG/CR-5512 Direction P

3 D

Z NUREG/CR-5512 Location of Center of Source: x,y,z (m)

P 3

D 4, 4, 0 Center of floor based on dimensions for scenario-defined room Source length X-axis (m)

P 2

D 8

Based on area dimensions (64 m2) for scenario-defined room

BHI Engineering ENG-OCS-002 RESRAD-Build Input Parameter Sensitivity Analysis-OCS Rev. 1 Page 8 of 24 RESRAD-BUILD Input Parameter Values for Sensitivity Analysis Building Occupancy Scenario Parameter Type Priority Treatment Value or Distribution Value/Distribution Reference Source Distribution's Statistical Parametersa 1

2 3

4 Source length Y-axis (m)

P 2

D 8

Based on area dimensions (64 m2) for scenario-defined room Area (m2)

P 2

D 64 Floor area for scenario-defined room Air Release Fraction for H-3 B

2 D

1.0 NUREG/CR-7267 Air Release Fraction (all nuclides other than H-3)

B 2

S Triangular NUREG/CR-6755, NUREG/CR-7267 1E-06 1.0 0.07 Direct Ingestion (h-1)

B 2

D 4.91E-7 NUREG/CR6755 Removable Fraction P

1 D

0.1 NUREG/CR-6755, NUREG/CR-5512 Time for Source Removal (d)

P 2

S Triangular NUREG/CR-6755, NUREG/CR-7267 1,000 100,000 10,000 Radionuclide Concentration (pCi/m2)

P 2

D 1.0 ROCs identified for OCS site Source 2: Wall 1 Type P

3 D

Area NUREG/CR-5512 Direction P

3 D

Y NUREG/CR-5512 Location of Center of Source: x,y,z (m)

P 3

D 4, 0, 1.5 Center of wall based on dimensions for scenario-defined room Source length X-axis (m)

P 2

D 8

Based on area dimensions (64 m2) for scenario-defined room Source length Z-axis (m)

P 2

D 3

Based on height (3 m) for scenario-defined room Area (m2)

P 2

D 24 Wall area for scenario defined room Air Release Fraction for H-3 B

2 D

1.0 NUREG/CR-7267 Air Release Fraction (all nuclides other than H-3)

B 2

S Triangular NUREG/CR-6755, NUREG/CR-7267 1E-06 1.0 0.07 Direct Ingestion (h-1)

B 2

D 4.91E-7 NUREG/CR-6755 Removable Fraction P

1 D

0.1 NUREG/CR-6755

BHI Engineering ENG-OCS-002 RESRAD-Build Input Parameter Sensitivity Analysis-OCS Rev. 1 Page 9 of 24 RESRAD-BUILD Input Parameter Values for Sensitivity Analysis Building Occupancy Scenario Parameter Type Priority Treatment Value or Distribution Value/Distribution Reference Source Distribution's Statistical Parametersa 1

2 3

4 Time for Source Removal (d)

P 2

S Triangular NUREG/CR-6755, NUREG/CR-7267 1,000 100,000 10,000 Radionuclide Concentration (pCi/m2)

P 2

D 1.0 ROCs identified for OCS site Source 3: Wall 2 Type P

3 D

Area NUREG/CR-5512 Direction P

3 D

X NUREG/CR-5512 Location of Center of Source: x,y,z (m)

P 3

D 0, 4, 1.5 center of wall based on dimensions for scenario-defined room Source length Y-axis (m)

P 2

D 8

Based on area dimensions (64 m2) for scenario-defined room Source length Z-axis (m)

P 2

D 3

Based on height (3 m) for scenario-defined room Area (m2)

P 2

D 24 Wall area for scenario defined room Air Release Fraction for H-3 B

2 D

1.0 NUREG/CR-7267 Air Release Fraction (all nuclides other than H-3)

B 2

S Triangular NUREG/CR-6755, NUREG/CR-7267 1E-06 1.0 0.07 Direct Ingestion (h-1)

B 2

D 4.91E-7 NUREG/CR-6755 Removable Fraction P

1 D

0.1 NUREG/CR-6755 Time for Source Removal (d)

P 2

S Triangular NUREG/CR-6755, NUREG/CR-7267 1,000 100,000 10,000 Radionuclide Concentration (pCi/m2)

P 2

D 1.0 ROCs identified for OCS site Source 4: Wall 3 Type P

3 D

area NUREG/CR-5512 Direction P

3 D

Y NUREG/CR-5512 Location of Center of Source: x,y,z (m)

P 3

D 4, 8, 1.5 center of wall based on dimensions for scenario-defined room

BHI Engineering ENG-OCS-002 RESRAD-Build Input Parameter Sensitivity Analysis-OCS Rev. 1 Page 10 of 24 RESRAD-BUILD Input Parameter Values for Sensitivity Analysis Building Occupancy Scenario Parameter Type Priority Treatment Value or Distribution Value/Distribution Reference Source Distribution's Statistical Parametersa 1

2 3

4 Source length X-axis (m)

P 2

D 8

Based on area dimensions (64 m2) for scenario-defined room Source length Z-axis (m)

P 2

D 3

Based on height (3 m) for scenario-defined room Area (m2)

P 2

D 24 Wall area for scenario defined room Air Release Fraction for H-3 B

2 D

1.0 NUREG/CR-7267 Air Release Fraction (all nuclides other than H-3)

B 2

S Triangular NUREG/CR-6755, NUREG/CR-7267 1E-06 1.0 0.07 Direct Ingestion (h-1)

B 2

D 4.91E-7 NUREG/CR-6755 Removable Fraction P

1 D

0.1 NUREG/CR-6755 Time for Source Removal (d)

P 2

S Triangular NUREG/CR-6755, NUREG/CR-7267 1,000 100,000 10,000 Radionuclide Concentration (pCi/m2)

P 2

D 1.0 ROCs identified for OCS site Source 5: Wall 4 Type P

3 D

area NUREG/CR-5512 Direction P

3 D

X NUREG/CR-5512 Location of Center of Source: x,y,z (m)

P 3

D 8, 4, 1.5 center of wall based on dimensions for scenario-defined room Source length Y-axis (m)

P 2

D 8

Based on area dimensions (64 m2) for scenario-defined room Source length Z-axis (m)

P 2

D 3

Based on height (3 m) for scenario-defined room Area (m2)

P 2

D 24 Wall area for scenario defined room Air Release Fraction for H-3 B

2 D

1.0 NUREG/CR-7267 Air Release Fraction (all nuclides other than H-3)

B 2

S Triangular NUREG/CR-6755, NUREG/CR-7267 1E-06 1.0 0.07 Direct Ingestion (h-1)

B 2

D 4.91E-7 NUREG/CR-6755

BHI Engineering ENG-OCS-002 RESRAD-Build Input Parameter Sensitivity Analysis-OCS Rev. 1 Page 11 of 24 RESRAD-BUILD Input Parameter Values for Sensitivity Analysis Building Occupancy Scenario Parameter Type Priority Treatment Value or Distribution Value/Distribution Reference Source Distribution's Statistical Parametersa 1

2 3

4 Removable Fraction P

1 D

0.1 NUREG/CR-6755 Time for Source Removal (d)

P 2

S Triangular NUREG/CR-6755, NUREG/CR-7267 1,000 100,000 10,000 Radionuclide Concentration (pCi/m2)

P 2

D 1.0 ROCs identified for OCS site Source 6: Ceiling Type P

3 D

Area NUREG/CR-5512 Direction P

3 D

Z NUREG/CR-5512 Location of Center of Source: x,y,z (m)

P 3

D 4, 4, 3 center of ceiling based on dimensions for scenario-defined room Source length X-axis (m)

P 2

D 8

Based on area dimensions (64 m2) for scenario-defined room Source length Y-axis (m)

P 2

D 8

Based on area dimensions (64 m2) for scenario-defined room Area (m2)

P 2

D 64 Ceiling area for scenario-defined room Air Release Fraction for H-3 B

2 D

1.0 NUREG/CR-7267 Air Release Fraction (all nuclides other than H-3)

B 2

S Triangular NUREG/CR-6755, NUREG/CR-7267 1E-06 1.0 0.07 Direct Ingestion (h-1)

B 2

D 4.91E-7 NUREG/CR-6755 Removable Fraction P

1 D

0.1 NUREG/CR-5512, NUREG/CR-6755 Time for Source Removal (d)

P 2

S Triangular NUREG/CR-6755, NUREG/CR-7267 1,000 100,000 10,000 Radionuclide Concentration (pCi/m2)

P 2

D 1.0 ROCs identified for OCS site Table notes:

a Distribution Statistical Parameters:

BHI Engineering ENG-OCS-002 RESRAD-Build Input Parameter Sensitivity Analysis-OCS Rev. 1 Page 12 of 24 Loguniform: 1= minimum, 2 = maximum Truncated lognormal-n: 1= mean, 2 = standard deviation, 3 = lower quantile, 4 = upper quantile Triangular: 1 = minimum, 2 = maximum, 3 = most likely Input Rank Correlation Coefficients:

Resuspension Rate and Deposition Velocity = 0.9 Time for source removal (correlation set between sources) = 0.9

BHI Engineering ENG-OCS-002 RESRAD-Build Input Parameter Sensitivity Analysis-OCS Rev. 1 Page 13 of 55 Table 3: PRCC Values Identifying Sensitive RESRAD-Build Parameters by Radionuclide ROC Source Number PRCC Values UD DKSUS LAMBDAT INGE AIRFR RFO (deposition velocity)

(resuspension rate)

(building air exchange rate)

(ingestion rate)

(air fraction)

(source release time)

Am-241 1

2 3

4 5

6 NSa NS NS NS NS NS NS NS NS NS NS NS

-0.92

-0.92

-0.92

-0.91

-0.92

-0.92 NS NS NS NS NS NS 0.91 0.92 0.90 0.90 0.91 0.91

-0.87

-0.89

-0.87

-0.86

-0.88

-0.87 C-14 1

2 3

4 5

6 0.23 0.27 0.29 0.32 0.34 0.30

-0.46

-0.51

-0.48

-0.53

-0.51

-0.51

-0.66

-0.65

-0.60

-0.69

-0.68

-0.67 0.24 0.25 0.25 0.30 0.25 0.33 0.59 0.58 0.55 0.60 0.62 0.61 0.61 0.61 0.64 0.60 0.63 0.65 Cm-243 1

2 3

4 5

6 NS NS NS NS NS NS NS NS NS NS NS NS

-0.92

-0.92

-0.92

-0.91

-0.92

-0.92 NS NS

-0.11 NS NS NS 0.91 0.92 0.90 0.90 0.91 0.91

-0.87

-0.89

-0.87

-0.87

-0.88

-0.87 Cm-244 1

2 3

4 5

6 NS NS NS NS NS NS NS NS NS NS NS NS

-0.92

-0.92

-0.92

-0.91

-0.92

-0.92 NS NS

-0.11 NS NS NS 0.91 0.92 0.90 0.90 0.91 0.91

-0.87

-0.89

-0.87

-0.87

-0.88

-0.87

BHI Engineering ENG-OCS-002 RESRAD-Build Input Parameter Sensitivity Analysis-OCS Rev. 1 Page 14 of 55 ROC Source Number PRCC Values UD DKSUS LAMBDAT INGE AIRFR RFO (deposition velocity)

(resuspension rate)

(building air exchange rate)

(ingestion rate)

(air fraction)

(source release time)

Co-60 1

2 3

4 5

6 NS NS 0.14 0.13 0.18 NS NS NS

-0.12

-0.16

-0.15 NS

-0.63

-0.76

-0.77

-0.77

-0.78

-0.69 NS NS NS NS NS NS 0.55 0.69 0.7 0.71 0.75 0.60 0.88 0.61 0.67 0.58 0.62 0.76 Cs-137 1

2 3

4 5

6 0.28 0.35 0.33 0.31 0.32 0.31

-0.35

-0.41

-0.40

-0.37

-0.39

-0.38

-0.52

-0.54

-0.50

-0.51

-0.53

-0.51 0.16 0.17 0.17 0.26 0.19 0.18 0.47 0.48 0.49 0.41 0.46 0.46 0.56 0.55 0.58 0.58 0.62 0.54 Eu-152 1

2 3

4 5

6 0.10 NS 0.12 0.14 0.25 NS

-0.11 NS NS

-0.19

-0.22 NS

-0.76

-0.83

-0.86

-0.83

-0.83

-0.82 NS NS

-0.12 NS NS NS 0.7 0.79 0.80 0.82 0.82 0.77 0.73 NS NS NS 0.15 0.52 Eu-154 1

2 3

4 5

6 NS NS NS 0.13 0.23 NS NS NS NS

-0.17

-0.20 NS

-0.78

-0.83

-0.86

-0.84

-0.84

-0.83 NS NS

-0.12 NS NS NS 0.73 0.81 0.80 0.83 0.83 0.79 0.69 NS

-0.17

-0.12 NS 0.40 Fe-55 1

2 3

4 5

6 NS NS NS NS 0.17 NS NS NS NS NS

-0.12 NS

-0.85

-0.84

-0.86

-0.84

-0.85

-0.85 NS NS NS NS NS NS 0.83 0.81 0.81 0.83 0.84 0.83 0.15 0.14 NS NS 0.21 NS

BHI Engineering ENG-OCS-002 RESRAD-Build Input Parameter Sensitivity Analysis-OCS Rev. 1 Page 15 of 55 ROC Source Number PRCC Values UD DKSUS LAMBDAT INGE AIRFR RFO (deposition velocity)

(resuspension rate)

(building air exchange rate)

(ingestion rate)

(air fraction)

(source release time)

H-3 1

2 3

4 5

6 0.44 0.38 0.38 0.43 0.40 0.37

-0.48

-0.46

-0.45

-0.49

-0.49

-0.43

-0.93

-0.93

-0.92

-0.93

-0.93

-0.93 0.22 0.22 0.25 0.28 0.22 0.22 NA -

Deterministic value of 1.0 used.

-0.33

-0.22

-0.17

-0.35

-0.21

-0.29 Mn-54 1

2 3

4 5

6 NS 0.21 0.16 0.13 0.23 0.12 NS

-0.17

-0.1

-0.12

-0.20 NS

-0.27

-0.46

-0.50

-0.47

-0.51

-0.34 NS NS NS NS NS NS 0.13 0.38 0.40 0.41 0.42 0.12 0.99 0.96 0.96 0.98 0.97 0.97 Nb-94 1

2 3

4 5

6 NS 0.14 0.22 0.23 0.32 0.14

-0.24

-0.32

-0.33

-0.39

-0.45

-0.26

-0.76

-0.85

-0.86

-0.84

-0.86

-0.84 NS NS NS NS NS 0.10 0.71 0.83 0.81 0.84 0.85 0.81 0.51

-0.33

-0.41

-0.33

-0.27 0.19 Ni-63 1

2 3

4 5

6 NS 0.10 0.16 0.16 0.20 NS

-0.11

-0.14

-0.18

-0.24

-0.22

-0.11

-0.88

-0.90

-0.89

-0.88

-0.89

-0.89 0.13 0.14 NS NS NS 0.16 0.88 0.89 0.86 0.88 0.89 0.87

-0.58

-0.63

-0.61

-0.58

-0.57

-0.56 Np-237 1

2 3

4 5

6 NS NS NS NS NS NS NS NS NS NS NS NS

-0.92

-0.92

-0.92

-0.91

-0.92

-0.92 NS 0.10 NS NS NS NS 0.91 0.91 0.90 0.90 0.91 0.91

-0.87

-0.89

-0.87

-0.86

-0.88

-0.87

BHI Engineering ENG-OCS-002 RESRAD-Build Input Parameter Sensitivity Analysis-OCS Rev. 1 Page 16 of 55 ROC Source Number PRCC Values UD DKSUS LAMBDAT INGE AIRFR RFO (deposition velocity)

(resuspension rate)

(building air exchange rate)

(ingestion rate)

(air fraction)

(source release time)

Pu-238 1

2 3

4 5

6 NS NS NS NS NS NS NS NS NS NS NS NS

-0.92

-0.92

-0.92

-0.91

-0.92

-0.92 NS NS

-0.10 NS NS NS 0.91 0.92 0.90 0.90 0.91 0.91

-0.87

-0.89

-0.87

-0.87

-0.88

-0.87 Pu-239 1

2 3

4 5

6 NS NS NS NS NS NS NS NS NS NS NS NS

-0.92

-0.92

-0.92

-0.91

-0.92

-0.92 NS 0.1 NS NS NS NS 0.91 0.91 0.90 0.90 0.91 0.91

-0.87

-0.89

-0.87

-0.86

-0.88

-0.87 Pu-240 1

2 3

4 5

6 NS NS NS NS NS NS NS NS NS NS NS NS

-0.92

-0.92

-0.92

-0.91

-0.92

-0.92 NS NS NS NS NS NS 0.91 0.92 0.90 0.90 0.91 0.91

-0.87

-0.89

-0.87

-0.86

-0.88

-0.87 Pu-241 1

2 3

4 5

6 NS NS NS NS NS NS NS NS NS NS NS NS

-0.92

-0.92

-0.92

-0.91

-0.92

-0.92 NS NS

-0.10 NS NS NS 0.91 0.92 0.90 0.90 0.91 0.91

-0.87

-0.89

-0.87

-0.86

-0.88

-0.87 Sb-125 1

2 3

4 5

6 NS 0.17 0.15 0.13 0.18 0.13 NS

-0.17

-0.12

-0.13

-0.13

-0.12

-0.49

-0.62

-0.62

-0.63

-0.67

-0.50 NS NS NS NS NS NS 0.37 0.54 0.58 0.50 0.59 0.47 0.97 0.88 0.89 0.87 0.87 0.91

BHI Engineering ENG-OCS-002 RESRAD-Build Input Parameter Sensitivity Analysis-OCS Rev. 1 Page 17 of 55 ROC Source Number PRCC Values UD DKSUS LAMBDAT INGE AIRFR RFO (deposition velocity)

(resuspension rate)

(building air exchange rate)

(ingestion rate)

(air fraction)

(source release time)

Sr-90 1

2 3

4 5

6 NS NS 0.13 0.15 0.19 NS NS NS

-0.13

-0.21

-0.18 NS

-0.88

-0.88

-0.89

-0.86

-0.88

-0.88 0.11 0.10 NS NS NS 0.14 0.88 0.87 0.85 0.87 0.88 0.86

-0.45

-0.44

-0.52

-0.43

-0.41

-0.43 Tc-99 1

2 3

4 5

6 0.12 0.13 0.22 0.23 0.35 0.12

-0.28

-0.31

-0.34

-0.40

-0.47

-0.29

-0.85

-0.84

-0.85

-0.84

-0.86

-0.84 0.21 0.21 0.12 0.20 0.15 0.28 0.84 0.82 0.80 0.83 0.85 0.82

-0.23

-0.24

-0.36

-0.25

-0.18

-0.25 a Not sensitive.

NOTE: The building air exchange rate, deposition velocity, resuspension rate, and ingestion rate characterize the room, which means if the parameter was identified as sensitive for one of the sources, then the 25th or 75th percentile value is applied to all 6 sources.

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 18 of 55 Table 4: Summary of 25th, 50th, and 75th Percentile Values for Sensitive Parameters Sensitive Parametera Percentile Value 25th 50th 75th LAMBDAT 8.4E-01 1.5E+00 2.7E+00 UD 1.5E-05 8.5E-05 4.8E-04 DKSUS 6.6E-10 1.8E-08 4.7E-07 INGE 5.0E-05 9.0E-05 1.6E-04 AIRFR(1) 1.6E-01 3.2E-01 5.2E-01 AIRFR(2) 1.6E-01 3.2E-01 5.2E-01 AIRFR(3) 1.6E-01 3.2E-01 5.2E-01 AIRFR(4) 1.6E-01 3.2E-01 5.2E-01 AIRFR(5) 1.6E-01 3.2E-01 5.2E-01 AIRFR(6) 1.6E-01 3.2E-01 5.2E-01 RFO(1) 1.8E+04 3.3E+04 5.3E+04 RFO(2) 1.8E+04 3.3E+04 5.3E+04 RFO(3) 1.8E+04 3.3E+04 5.3E+04 RFO(4) 1.8E+04 3.3E+04 5.3E+04 RFO(5) 1.8E+04 3.3E+04 5.3E+04 RFO(6) 1.8E+04 3.3E+04 5.3E+04 a LAMBDAT = building air exchange rate, UD = deposition velocity, DKSUS = resuspension rate, INGE

= ingestion rate, AIRFR(#) = air release fraction (for source number), and RFO(#) = source removal time (for source number).

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 19 of 55 Appendix A RESRAD-Build 3.5 Results

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 20 of 55 Am-241 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/15/22 11:22:21 Page: 37 **

Title : OCS Sensitivity Analysis - Am241 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 14 0.01 14 0.01 16 0.00 16 0.00 Resuspension Rate 13 -0.02 11 -0.02 10 -0.03 6 -0.02 Building Exchange Rate 3 -0.25 3 -0.23 1 -0.92 1 -0.61 Receptor Ingestion Rate of receptor 1 15 0.01 15 0.01 7 0.04 8 0.01 Air fraction of 1 2 0.26 2 0.24 2 0.91 2 0.59 Release time of 1 1 -0.33 1 -0.31 3 -0.87 3 -0.47 Air fraction of 2 9 -0.04 9 -0.04 8 -0.04 9 -0.01 Release time of 2 4 0.09 4 0.08 14 0.00 14 0.00 Air fraction of 3 16 0.00 16 0.00 6 0.04 7 0.01 Release time of 3 12 0.02 13 0.01 5 0.08 5 0.02 Air fraction of 4 7 -0.04 7 -0.04 11 0.03 11 0.01 Release time of 4 8 -0.04 8 -0.04 12 -0.02 12 -0.01 Air fraction of 5 10 0.04 10 0.03 9 -0.04 10 -0.01 Release time of 5 6 -0.05 6 -0.04 15 0.00 15 0.00 Air fraction of 6 5 0.05 5 0.04 4 0.12 4 0.03 Release time of 6 11 -0.02 12 -0.02 13 -0.01 13 0.00

    • RESRAD-BUILD Regression and Correlation output 3.50 02/15/22 11:22:21 Page: 38 **

Title : OCS Sensitivity Analysis - Am241 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(2) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 15 -0.02 15 -0.03 9 0.04 5 0.02 Resuspension Rate 16 -0.01 16 -0.01 16 0.01 14 0.00 Building Exchange Rate 2 -0.27 2 -0.25 1 -0.92 1 -0.60 Receptor Ingestion Rate of receptor 1 4 0.09 4 0.08 5 0.09 6 0.02 Air fraction of 1 13 0.05 13 0.04 7 -0.04 8 -0.01 Release time of 1 6 -0.08 6 -0.07 13 0.03 13 0.01 Air fraction of 2 3 0.25 3 0.22 2 0.92 2 0.58 Release time of 2 1 -0.33 1 -0.31 3 -0.89 3 -0.50 Air fraction of 3 10 0.05 10 0.05 15 -0.01 16 0.00 Release time of 3 9 -0.06 9 -0.05 14 -0.01 15 0.00 Air fraction of 4 7 0.07 7 0.06 4 -0.14 4 -0.04 Release time of 4 11 -0.05 12 -0.04 11 -0.03 11 -0.01 Air fraction of 5 14 0.04 14 0.04 12 0.03 12 0.01 Release time of 5 12 -0.05 11 -0.04 10 0.04 10 0.01 Air fraction of 6 5 0.09 5 0.08 8 0.04 9 0.01 Release time of 6 8 -0.07 8 -0.06 6 0.07 7 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/15/22 11:22:21 Page: 39 **

Title : OCS Sensitivity Analysis - Am241 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.12 4 0.15 9 0.05 5 0.03 Resuspension Rate 5 -0.09 5 -0.12 13 -0.03 9 -0.02 Building Exchange Rate 3 -0.38 3 -0.33 1 -0.92 1 -0.62 Receptor Ingestion Rate of receptor 1 10 0.03 10 0.02 5 -0.09 6 -0.03 Air fraction of 1 7 0.06 7 0.05 6 -0.07 7 -0.02 Release time of 1 8 -0.04 8 -0.03 11 -0.04 12 -0.01 Air fraction of 2 12 -0.02 12 -0.01 4 -0.11 4 -0.03 Release time of 2 16 0.00 16 0.00 8 -0.06 10 -0.02 Air fraction of 3 2 0.39 2 0.34 2 0.90 2 0.56 Release time of 3 1 -0.44 1 -0.39 3 -0.87 3 -0.48 Air fraction of 4 9 0.03 9 0.03 14 -0.03 14 -0.01 Release time of 4 13 0.02 13 0.01 15 0.02 15 0.01 Air fraction of 5 11 0.02 11 0.01 16 -0.01 16 0.00 Release time of 5 14 0.02 14 0.01 10 -0.04 11 -0.01 Air fraction of 6 15 0.01 15 0.01 12 -0.04 13 -0.01 Release time of 6 6 -0.06 6 -0.05 7 0.07 8 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/15/22 11:22:21 Page: 40 **

Title : OCS Sensitivity Analysis - Am241 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 10 0.03 9 0.04 16 0.01 13 0.01 Resuspension Rate 7 -0.07 6 -0.10 9 -0.04 6 -0.02 Building Exchange Rate 3 -0.31 3 -0.27 1 -0.91 1 -0.61 Receptor Ingestion Rate of receptor 1 5 0.15 5 0.12 11 -0.04 11 -0.01

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 21 of 55 Air fraction of 1 16 0.00 16 0.00 7 -0.05 8 -0.01 Release time of 1 12 -0.03 12 -0.02 4 -0.12 4 -0.03 Air fraction of 2 14 -0.02 14 -0.01 12 0.04 12 0.01 Release time of 2 13 0.02 13 0.02 10 0.04 10 0.01 Air fraction of 3 6 0.08 7 0.06 8 -0.05 9 -0.01 Release time of 3 9 -0.05 10 -0.04 13 0.02 14 0.01 Air fraction of 4 1 0.42 1 0.37 2 0.90 2 0.58 Release time of 4 2 -0.39 2 -0.34 3 -0.86 3 -0.47 Air fraction of 5 15 -0.02 15 -0.01 14 -0.02 15 -0.01 Release time of 5 11 -0.03 11 -0.03 15 0.02 16 0.00 Air fraction of 6 4 0.16 4 0.13 6 0.08 7 0.02 Release time of 6 8 -0.06 8 -0.05 5 0.11 5 0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/15/22 11:22:21 Page: 41 **

Title : OCS Sensitivity Analysis - Am241 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.08 4 0.11 6 0.05 5 0.03 Resuspension Rate 6 -0.06 5 -0.09 8 -0.04 6 -0.03 Building Exchange Rate 3 -0.34 3 -0.29 1 -0.92 1 -0.61 Receptor Ingestion Rate of receptor 1 13 0.01 13 0.01 10 -0.04 10 -0.01 Air fraction of 1 11 0.02 11 0.01 15 0.00 15 0.00 Release time of 1 7 0.05 7 0.04 14 0.01 14 0.00 Air fraction of 2 16 0.00 16 0.00 5 0.06 7 0.02 Release time of 2 8 -0.05 8 -0.04 16 0.00 16 0.00 Air fraction of 3 9 0.02 9 0.02 11 0.02 11 0.00 Release time of 3 5 -0.07 6 -0.06 9 -0.04 9 -0.01 Air fraction of 4 10 0.02 10 0.02 12 0.02 12 0.00 Release time of 4 14 -0.01 14 0.00 13 -0.02 13 0.00 Air fraction of 5 1 0.39 1 0.35 2 0.91 2 0.56 Release time of 5 2 -0.38 2 -0.34 3 -0.88 3 -0.47 Air fraction of 6 15 0.00 15 0.00 4 0.12 4 0.03 Release time of 6 12 -0.01 12 -0.01 7 0.05 8 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/15/22 11:22:21 Page: 42 **

Title : OCS Sensitivity Analysis - Am241 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 15 -0.01 13 -0.02 13 0.02 10 0.01 Resuspension Rate 12 0.02 10 0.03 12 -0.02 8 -0.01 Building Exchange Rate 3 -0.19 3 -0.18 1 -0.92 1 -0.63 Receptor Ingestion Rate of receptor 1 16 0.00 16 0.00 11 -0.03 13 -0.01 Air fraction of 1 14 0.01 15 0.01 4 0.12 4 0.03 Release time of 1 5 0.06 5 0.05 10 0.03 12 0.01 Air fraction of 2 4 0.06 4 0.06 16 -0.01 16 0.00 Release time of 2 11 0.02 12 0.02 8 0.05 9 0.01 Air fraction of 3 8 0.05 8 0.04 9 -0.03 11 -0.01 Release time of 3 6 -0.05 6 -0.05 7 -0.06 7 -0.02 Air fraction of 4 10 -0.04 11 -0.03 6 0.06 6 0.02 Release time of 4 7 -0.05 7 -0.04 15 0.02 15 0.00 Air fraction of 5 9 -0.04 9 -0.04 14 0.02 14 0.00 Release time of 5 13 -0.02 14 -0.02 5 -0.08 5 -0.02 Air fraction of 6 2 0.24 2 0.23 2 0.91 2 0.57 Release time of 6 1 -0.24 1 -0.23 3 -0.87 3 -0.46 C-14 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 16:39:51 Page: 37 **

Title : OCS SA_C14 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 6 -0.07 4 -0.11 6 0.23 5 0.28 Resuspension Rate 16 0.00 16 0.00 4 -0.46 1 -0.62 Building Exchange Rate 2 -0.17 2 -0.16 1 -0.66 2 -0.47 Receptor Ingestion Rate of receptor 1 3 0.14 3 0.13 5 0.24 6 0.13 Air fraction of 1 1 0.24 1 0.23 3 0.59 4 0.39 Release time of 1 11 -0.03 11 -0.03 2 0.61 3 0.42 Air fraction of 2 4 0.08 5 0.08 8 -0.06 8 -0.03 Release time of 2 10 0.04 10 0.04 14 -0.02 14 -0.01 Air fraction of 3 15 0.00 15 0.00 12 0.04 12 0.02 Release time of 3 9 -0.04 9 -0.04 11 0.05 11 0.03 Air fraction of 4 13 -0.02 13 -0.02 15 0.02 15 0.01 Release time of 4 8 -0.05 8 -0.05 9 -0.06 9 -0.03 Air fraction of 5 5 -0.08 6 -0.07 13 0.03 13 0.02 Release time of 5 12 0.03 12 0.03 16 0.02 16 0.01 Air fraction of 6 14 0.02 14 0.02 7 0.08 7 0.05 Release time of 6 7 0.05 7 0.05 10 0.05 10 0.03

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 22 of 55

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 16:39:51 Page: 38 **

Title : OCS SA_C14 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(2) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 -0.10 3 -0.15 5 0.27 5 0.33 Resuspension Rate 16 0.00 16 0.00 4 -0.51 1 -0.70 Building Exchange Rate 2 -0.21 2 -0.20 1 -0.65 2 -0.45 Receptor Ingestion Rate of receptor 1 3 0.13 4 0.13 6 0.25 6 0.13 Air fraction of 1 11 0.02 11 0.02 7 -0.13 7 -0.07 Release time of 1 13 -0.02 13 -0.01 14 0.03 14 0.02 Air fraction of 2 1 0.25 1 0.24 3 0.58 4 0.37 Release time of 2 15 -0.01 15 -0.01 2 0.61 3 0.41 Air fraction of 3 9 0.04 9 0.04 12 0.04 12 0.02 Release time of 3 14 -0.01 14 -0.01 8 0.08 8 0.04 Air fraction of 4 12 -0.02 12 -0.02 16 0.00 16 0.00 Release time of 4 5 -0.06 5 -0.06 10 0.07 10 0.04 Air fraction of 5 7 -0.05 7 -0.04 15 -0.03 15 -0.02 Release time of 5 10 0.04 10 0.04 11 -0.04 11 -0.02 Air fraction of 6 6 0.05 6 0.05 9 0.07 9 0.04 Release time of 6 8 -0.04 8 -0.04 13 -0.04 13 -0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 16:39:51 Page: 39 **

Title : OCS SA_C14 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 9 -0.05 7 -0.08 5 0.29 4 0.38 Resuspension Rate 15 0.00 15 -0.01 4 -0.48 1 -0.69 Building Exchange Rate 2 -0.16 2 -0.15 2 -0.60 3 -0.41 Receptor Ingestion Rate of receptor 1 1 0.18 1 0.17 6 0.25 6 0.14 Air fraction of 1 3 0.15 3 0.15 12 0.06 12 0.03 Release time of 1 11 -0.02 11 -0.02 16 0.00 16 0.00 Air fraction of 2 5 0.12 5 0.11 11 -0.06 11 -0.03 Release time of 2 6 0.09 6 0.09 8 -0.08 8 -0.05 Air fraction of 3 4 0.15 4 0.14 3 0.55 5 0.37 Release time of 3 13 0.01 13 0.01 1 0.64 2 0.46 Air fraction of 4 16 0.00 16 0.00 10 0.07 10 0.04 Release time of 4 10 0.03 10 0.02 15 -0.01 15 -0.01 Air fraction of 5 12 -0.02 12 -0.02 7 -0.10 7 -0.06 Release time of 5 8 0.05 9 0.05 14 -0.02 14 -0.01 Air fraction of 6 14 0.01 14 0.01 13 0.02 13 0.01 Release time of 6 7 -0.07 8 -0.06 9 -0.08 9 -0.04

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 16:39:51 Page: 40 **

Title : OCS SA_C14 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 5 -0.09 4 -0.13 5 0.32 3 0.39 Resuspension Rate 15 0.01 14 0.02 4 -0.53 1 -0.73 Building Exchange Rate 3 -0.19 3 -0.18 1 -0.69 2 -0.49 Receptor Ingestion Rate of receptor 1 2 0.22 2 0.20 6 0.30 6 0.16 Air fraction of 1 7 0.07 7 0.06 9 0.03 9 0.02 Release time of 1 6 0.08 6 0.08 10 0.03 10 0.01 Air fraction of 2 16 0.00 16 0.00 15 0.01 15 0.01 Release time of 2 11 0.04 11 0.04 12 -0.02 12 -0.01 Air fraction of 3 10 -0.05 10 -0.04 14 -0.02 14 -0.01 Release time of 3 13 -0.02 13 -0.02 11 0.02 11 0.01 Air fraction of 4 1 0.25 1 0.23 3 0.60 5 0.38 Release time of 4 8 -0.05 8 -0.05 2 0.60 4 0.38 Air fraction of 5 14 -0.01 15 -0.01 8 -0.06 8 -0.03 Release time of 5 9 0.05 9 0.05 16 0.01 16 0.00 Air fraction of 6 4 0.12 5 0.11 7 0.16 7 0.08 Release time of 6 12 -0.03 12 -0.03 13 -0.02 13 -0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 16:39:51 Page: 41 **

Title : OCS SA_C14 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 6 -0.10 5 -0.14 5 0.34 3 0.44 Resuspension Rate 13 0.01 12 0.02 4 -0.51 1 -0.69 Building Exchange Rate 2 -0.25 2 -0.23 1 -0.68 2 -0.49 Receptor Ingestion Rate of receptor 1 3 0.23 3 0.21 6 0.25 6 0.13 Air fraction of 1 14 -0.01 14 -0.01 11 0.06 11 0.03 Release time of 1 8 0.07 8 0.06 7 -0.12 7 -0.06 Air fraction of 2 12 0.02 13 0.02 15 -0.01 15 0.00

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 23 of 55 Release time of 2 9 -0.07 9 -0.06 8 -0.08 8 -0.04 Air fraction of 3 10 0.04 10 0.03 9 0.07 9 0.04 Release time of 3 7 0.09 7 0.08 14 -0.03 14 -0.01 Air fraction of 4 15 0.00 15 0.00 12 0.05 12 0.03 Release time of 4 16 0.00 16 0.00 16 0.00 16 0.00 Air fraction of 5 1 0.32 1 0.29 3 0.62 5 0.42 Release time of 5 4 0.20 4 0.18 2 0.63 4 0.42 Air fraction of 6 11 0.03 11 0.03 13 0.04 13 0.02 Release time of 6 5 -0.13 6 -0.12 10 -0.06 10 -0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 16:39:51 Page: 42 **

Title : OCS SA_C14 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 16 0.00 16 0.00 6 0.30 5 0.36 Resuspension Rate 12 -0.03 8 -0.05 4 -0.51 1 -0.69 Building Exchange Rate 2 -0.11 2 -0.11 1 -0.67 2 -0.46 Receptor Ingestion Rate of receptor 1 15 0.00 15 0.00 5 0.33 6 0.18 Air fraction of 1 8 0.04 9 0.04 16 0.00 16 0.00 Release time of 1 5 0.09 5 0.08 9 0.04 9 0.02 Air fraction of 2 4 0.09 4 0.08 12 0.03 12 0.01 Release time of 2 9 0.04 10 0.04 15 0.01 15 0.00 Air fraction of 3 11 0.03 12 0.03 14 0.02 14 0.01 Release time of 3 13 -0.02 13 -0.02 11 0.03 11 0.02 Air fraction of 4 6 -0.07 6 -0.06 7 0.05 7 0.03 Release time of 4 7 -0.05 7 -0.05 10 0.03 10 0.02 Air fraction of 5 10 -0.04 11 -0.04 8 -0.05 8 -0.02 Release time of 5 14 0.02 14 0.02 13 -0.02 13 -0.01 Air fraction of 6 1 0.15 1 0.15 3 0.61 4 0.39 Release time of 6 3 -0.10 3 -0.09 2 0.65 3 0.43 Cm-243 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:52:06 Page: 37 **

Title : OCS SA_Cm243 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 14 0.01 14 0.02 11 -0.02 6 -0.01 Resuspension Rate 13 -0.01 11 -0.02 13 0.01 13 0.00 Building Exchange Rate 3 -0.25 3 -0.23 1 -0.92 1 -0.61 Receptor Ingestion Rate of receptor 1 15 0.01 15 0.01 10 0.03 11 0.01 Air fraction of 1 2 0.26 2 0.24 2 0.91 2 0.59 Release time of 1 1 -0.33 1 -0.31 3 -0.87 3 -0.47 Air fraction of 2 6 -0.05 6 -0.04 6 -0.04 8 -0.01 Release time of 2 4 0.09 4 0.08 15 0.01 15 0.00 Air fraction of 3 16 0.00 16 0.00 7 0.04 7 0.01 Release time of 3 12 0.02 13 0.02 5 0.08 5 0.02 Air fraction of 4 9 -0.04 9 -0.04 9 0.03 10 0.01 Release time of 4 10 -0.04 10 -0.04 12 -0.02 12 -0.01 Air fraction of 5 8 0.04 8 0.04 8 -0.04 9 -0.01 Release time of 5 5 -0.05 5 -0.04 14 0.01 14 0.00 Air fraction of 6 7 0.04 7 0.04 4 0.12 4 0.03 Release time of 6 11 -0.02 12 -0.02 16 0.00 16 0.00

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:52:06 Page: 38 **

Title : OCS SA_Cm243 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(2) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 15 -0.02 15 -0.03 14 0.02 11 0.01 Resuspension Rate 16 -0.01 16 -0.01 8 0.05 5 0.03 Building Exchange Rate 2 -0.27 2 -0.25 1 -0.92 1 -0.60 Receptor Ingestion Rate of receptor 1 4 0.09 4 0.08 5 0.08 6 0.02 Air fraction of 1 13 0.05 13 0.04 7 -0.05 8 -0.01 Release time of 1 6 -0.08 6 -0.07 13 0.03 14 0.01 Air fraction of 2 3 0.24 3 0.22 2 0.92 2 0.58 Release time of 2 1 -0.34 1 -0.31 3 -0.89 3 -0.50 Air fraction of 3 11 0.05 11 0.04 15 -0.01 15 0.00 Release time of 3 9 -0.06 9 -0.05 16 -0.01 16 0.00 Air fraction of 4 7 0.07 7 0.06 4 -0.13 4 -0.03 Release time of 4 12 -0.05 12 -0.04 11 -0.03 12 -0.01 Air fraction of 5 14 0.05 14 0.04 12 0.03 13 0.01 Release time of 5 10 -0.05 10 -0.04 10 0.04 10 0.01 Air fraction of 6 5 0.09 5 0.08 9 0.04 9 0.01 Release time of 6 8 -0.06 8 -0.06 6 0.07 7 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:52:06 Page: 39 **

Title : OCS SA_Cm243

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 24 of 55 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.12 4 0.16 13 0.02 10 0.01 Resuspension Rate 5 -0.09 5 -0.12 15 0.01 14 0.01 Building Exchange Rate 3 -0.38 3 -0.33 1 -0.92 1 -0.62 Receptor Ingestion Rate of receptor 1 11 0.03 11 0.02 5 -0.11 5 -0.03 Air fraction of 1 7 0.05 7 0.04 6 -0.08 6 -0.02 Release time of 1 8 -0.05 8 -0.04 10 -0.04 11 -0.01 Air fraction of 2 10 -0.03 10 -0.02 4 -0.11 4 -0.03 Release time of 2 15 -0.01 15 0.00 8 -0.06 8 -0.02 Air fraction of 3 2 0.39 2 0.34 2 0.90 2 0.56 Release time of 3 1 -0.45 1 -0.40 3 -0.87 3 -0.48 Air fraction of 4 9 0.04 9 0.03 14 -0.02 15 0.00 Release time of 4 13 0.02 13 0.02 12 0.02 13 0.01 Air fraction of 5 12 0.03 12 0.02 16 0.00 16 0.00 Release time of 5 14 0.01 14 0.01 9 -0.04 9 -0.01 Air fraction of 6 16 0.00 16 0.00 11 -0.03 12 -0.01 Release time of 6 6 -0.05 6 -0.04 7 0.07 7 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:52:06 Page: 40 **

Title : OCS SA_Cm243 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 10 0.03 9 0.05 14 -0.02 10 -0.01 Resuspension Rate 7 -0.07 6 -0.10 16 0.00 16 0.00 Building Exchange Rate 3 -0.31 3 -0.27 1 -0.91 1 -0.61 Receptor Ingestion Rate of receptor 1 5 0.15 5 0.12 8 -0.05 8 -0.01 Air fraction of 1 16 -0.01 16 -0.01 7 -0.06 7 -0.02 Release time of 1 12 -0.03 12 -0.02 4 -0.11 4 -0.03 Air fraction of 2 14 -0.02 14 -0.02 12 0.03 13 0.01 Release time of 2 13 0.02 13 0.02 10 0.04 11 0.01 Air fraction of 3 6 0.08 7 0.06 9 -0.05 9 -0.01 Release time of 3 9 -0.05 10 -0.04 11 0.03 12 0.01 Air fraction of 4 1 0.42 1 0.37 2 0.90 2 0.58 Release time of 4 2 -0.39 2 -0.34 3 -0.87 3 -0.47 Air fraction of 5 15 -0.01 15 -0.01 13 -0.02 14 -0.01 Release time of 5 11 -0.03 11 -0.03 15 0.02 15 0.00 Air fraction of 6 4 0.16 4 0.13 6 0.08 6 0.02 Release time of 6 8 -0.06 8 -0.05 5 0.11 5 0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:52:06 Page: 41 **

Title : OCS SA_Cm243 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.08 4 0.11 11 0.01 9 0.01 Resuspension Rate 6 -0.06 5 -0.09 15 0.01 13 0.00 Building Exchange Rate 3 -0.33 3 -0.29 1 -0.92 1 -0.61 Receptor Ingestion Rate of receptor 1 13 0.01 13 0.01 7 -0.05 7 -0.01 Air fraction of 1 11 0.02 11 0.01 13 -0.01 14 0.00 Release time of 1 7 0.05 7 0.04 12 0.01 12 0.00 Air fraction of 2 15 0.00 15 0.00 5 0.05 5 0.01 Release time of 2 8 -0.05 8 -0.04 16 0.00 16 0.00 Air fraction of 3 10 0.02 10 0.02 10 0.02 11 0.01 Release time of 3 5 -0.07 6 -0.06 8 -0.04 8 -0.01 Air fraction of 4 9 0.03 9 0.02 9 0.02 10 0.01 Release time of 4 14 0.00 14 0.00 14 -0.01 15 0.00 Air fraction of 5 1 0.40 1 0.35 2 0.91 2 0.56 Release time of 5 2 -0.38 2 -0.34 3 -0.88 3 -0.47 Air fraction of 6 16 0.00 16 0.00 4 0.12 4 0.03 Release time of 6 12 -0.01 12 -0.01 6 0.05 6 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:52:06 Page: 42 **

Title : OCS SA_Cm243 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 13 -0.02 11 -0.03 16 0.00 16 0.00 Resuspension Rate 8 0.04 4 0.07 14 0.01 12 0.01 Building Exchange Rate 3 -0.23 3 -0.22 1 -0.92 1 -0.63 Receptor Ingestion Rate of receptor 1 12 0.02 13 0.02 9 -0.04 9 -0.01 Air fraction of 1 16 0.00 16 0.00 4 0.12 4 0.03 Release time of 1 6 0.05 7 0.04 10 0.04 10 0.01 Air fraction of 2 5 0.05 6 0.04 15 -0.01 15 0.00 Release time of 2 15 0.01 15 0.01 8 0.05 8 0.01 Air fraction of 3 7 0.04 8 0.04 11 -0.03 11 -0.01

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 25 of 55 Release time of 3 4 -0.06 5 -0.05 7 -0.06 7 -0.02 Air fraction of 4 14 -0.02 14 -0.02 6 0.06 6 0.02 Release time of 4 9 -0.04 9 -0.04 13 0.02 14 0.00 Air fraction of 5 10 -0.04 10 -0.03 12 0.02 13 0.01 Release time of 5 11 -0.03 12 -0.03 5 -0.07 5 -0.02 Air fraction of 6 2 0.28 2 0.27 2 0.91 2 0.58 Release time of 6 1 -0.28 1 -0.27 3 -0.87 3 -0.46 Cm-244 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 08:34:38 Page: 37 **

Title : OCS SA_Cm244 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 14 0.01 14 0.02 11 -0.03 6 -0.02 Resuspension Rate 13 -0.01 11 -0.02 13 0.02 10 0.01 Building Exchange Rate 3 -0.25 3 -0.23 1 -0.92 1 -0.61 Receptor Ingestion Rate of receptor 1 15 0.01 15 0.01 10 0.03 12 0.01 Air fraction of 1 2 0.26 2 0.23 2 0.91 2 0.59 Release time of 1 1 -0.33 1 -0.31 3 -0.87 3 -0.47 Air fraction of 2 5 -0.05 6 -0.04 6 -0.04 7 -0.01 Release time of 2 4 0.09 4 0.08 15 0.01 15 0.00 Air fraction of 3 16 0.00 16 0.00 7 0.04 8 0.01 Release time of 3 11 0.02 12 0.02 5 0.08 5 0.02 Air fraction of 4 9 -0.04 9 -0.04 9 0.03 11 0.01 Release time of 4 10 -0.04 10 -0.03 12 -0.02 13 -0.01 Air fraction of 5 7 0.04 7 0.04 8 -0.04 9 -0.01 Release time of 5 6 -0.05 5 -0.04 14 0.01 14 0.00 Air fraction of 6 8 0.04 8 0.04 4 0.12 4 0.03 Release time of 6 12 -0.02 13 -0.02 16 0.00 16 0.00

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 08:34:38 Page: 38 **

Title : OCS SA_Cm244 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(2) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 15 -0.02 15 -0.03 16 0.01 14 0.00 Resuspension Rate 16 -0.01 16 -0.01 7 0.06 5 0.03 Building Exchange Rate 2 -0.27 2 -0.25 1 -0.92 1 -0.60 Receptor Ingestion Rate of receptor 1 4 0.09 4 0.08 5 0.07 6 0.02 Air fraction of 1 13 0.05 13 0.04 8 -0.05 8 -0.01 Release time of 1 6 -0.08 6 -0.07 13 0.02 13 0.01 Air fraction of 2 3 0.24 3 0.22 2 0.92 2 0.58 Release time of 2 1 -0.34 1 -0.31 3 -0.89 3 -0.50 Air fraction of 3 11 0.05 11 0.04 14 -0.01 15 0.00 Release time of 3 9 -0.06 9 -0.05 15 -0.01 16 0.00 Air fraction of 4 7 0.08 7 0.07 4 -0.13 4 -0.03 Release time of 4 12 -0.05 12 -0.04 11 -0.03 11 -0.01 Air fraction of 5 14 0.05 14 0.04 12 0.03 12 0.01 Release time of 5 10 -0.05 10 -0.04 9 0.04 9 0.01 Air fraction of 6 5 0.08 5 0.07 10 0.04 10 0.01 Release time of 6 8 -0.06 8 -0.06 6 0.07 7 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 08:34:38 Page: 39 **

Title : OCS SA_Cm244 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.12 4 0.16 15 0.01 14 0.00 Resuspension Rate 5 -0.09 5 -0.12 13 0.02 9 0.01 Building Exchange Rate 3 -0.38 3 -0.33 1 -0.92 1 -0.62 Receptor Ingestion Rate of receptor 1 11 0.03 11 0.02 5 -0.11 5 -0.03 Air fraction of 1 8 0.05 8 0.04 6 -0.08 6 -0.02 Release time of 1 6 -0.05 6 -0.04 10 -0.04 11 -0.01 Air fraction of 2 10 -0.03 10 -0.03 4 -0.11 4 -0.03 Release time of 2 15 -0.01 15 -0.01 8 -0.06 8 -0.02 Air fraction of 3 2 0.39 2 0.34 2 0.90 2 0.56 Release time of 3 1 -0.45 1 -0.40 3 -0.87 3 -0.48 Air fraction of 4 9 0.04 9 0.03 14 -0.01 15 0.00 Release time of 4 13 0.02 13 0.02 12 0.02 13 0.01 Air fraction of 5 12 0.03 12 0.02 16 0.00 16 0.00 Release time of 5 14 0.01 14 0.01 9 -0.04 10 -0.01 Air fraction of 6 16 0.00 16 0.00 11 -0.03 12 -0.01 Release time of 6 7 -0.05 7 -0.04 7 0.07 7 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 08:34:38 Page: 40 **

Title : OCS SA_Cm244 Input File : C:\RESRAD_Family\BUILD\3.BLD

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 26 of 55 Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 10 0.03 9 0.05 12 -0.03 7 -0.02 Resuspension Rate 7 -0.07 6 -0.10 16 0.01 13 0.01 Building Exchange Rate 3 -0.31 3 -0.27 1 -0.91 1 -0.61 Receptor Ingestion Rate of receptor 1 5 0.15 5 0.12 8 -0.05 9 -0.01 Air fraction of 1 16 -0.01 16 -0.01 7 -0.06 8 -0.02 Release time of 1 12 -0.03 12 -0.02 4 -0.12 4 -0.03 Air fraction of 2 14 -0.02 14 -0.02 13 0.02 14 0.01 Release time of 2 13 0.02 13 0.02 10 0.04 11 0.01 Air fraction of 3 6 0.08 7 0.06 9 -0.05 10 -0.01 Release time of 3 9 -0.05 10 -0.04 11 0.03 12 0.01 Air fraction of 4 1 0.42 1 0.37 2 0.90 2 0.58 Release time of 4 2 -0.39 2 -0.34 3 -0.87 3 -0.47 Air fraction of 5 15 -0.01 15 -0.01 15 -0.02 16 0.00 Release time of 5 11 -0.03 11 -0.03 14 0.02 15 0.01 Air fraction of 6 4 0.16 4 0.13 6 0.08 6 0.02 Release time of 6 8 -0.06 8 -0.05 5 0.12 5 0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 08:34:38 Page: 41 **

Title : OCS SA_Cm244 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.08 4 0.11 15 0.00 14 0.00 Resuspension Rate 6 -0.06 5 -0.09 11 0.02 9 0.01 Building Exchange Rate 3 -0.33 3 -0.29 1 -0.92 1 -0.61 Receptor Ingestion Rate of receptor 1 13 0.01 13 0.01 6 -0.05 6 -0.01 Air fraction of 1 11 0.02 11 0.01 13 -0.01 13 0.00 Release time of 1 7 0.05 7 0.04 12 0.01 12 0.00 Air fraction of 2 14 0.00 14 0.00 7 0.05 7 0.01 Release time of 2 8 -0.05 8 -0.04 16 0.00 16 0.00 Air fraction of 3 10 0.02 10 0.02 10 0.02 11 0.00 Release time of 3 5 -0.07 6 -0.06 8 -0.04 8 -0.01 Air fraction of 4 9 0.03 9 0.02 9 0.02 10 0.01 Release time of 4 15 0.00 15 0.00 14 -0.01 15 0.00 Air fraction of 5 1 0.40 1 0.35 2 0.91 2 0.56 Release time of 5 2 -0.38 2 -0.34 3 -0.88 3 -0.47 Air fraction of 6 16 0.00 16 0.00 4 0.12 4 0.03 Release time of 6 12 -0.01 12 -0.01 5 0.05 5 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 08:34:38 Page: 42 **

Title : OCS SA_Cm244 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 13 -0.02 9 -0.04 15 -0.01 14 -0.01 Resuspension Rate 5 0.05 4 0.08 13 0.02 9 0.01 Building Exchange Rate 3 -0.25 3 -0.23 1 -0.92 1 -0.63 Receptor Ingestion Rate of receptor 1 12 0.03 13 0.03 9 -0.04 10 -0.01 Air fraction of 1 16 -0.01 16 -0.01 4 0.12 4 0.03 Release time of 1 9 0.04 10 0.04 10 0.03 11 0.01 Air fraction of 2 8 0.04 8 0.04 16 -0.01 16 0.00 Release time of 2 15 0.01 15 0.01 8 0.05 8 0.01 Air fraction of 3 6 0.04 6 0.04 11 -0.03 12 -0.01 Release time of 3 4 -0.06 5 -0.06 6 -0.06 6 -0.02 Air fraction of 4 14 -0.01 14 -0.01 7 0.06 7 0.02 Release time of 4 7 -0.04 7 -0.04 14 0.02 15 0.00 Air fraction of 5 10 -0.04 11 -0.03 12 0.02 13 0.01 Release time of 5 11 -0.03 12 -0.03 5 -0.07 5 -0.02 Air fraction of 6 2 0.30 2 0.28 2 0.91 2 0.58 Release time of 6 1 -0.30 1 -0.28 3 -0.87 3 -0.46 Co-60 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 17:03:33 Page: 37 **

Title : OCS SA_Co60 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 9 0.03 8 0.04 8 0.05 6 0.05 Resuspension Rate 16 0.00 16 0.00 7 -0.06 5 -0.06 Building Exchange Rate 3 -0.26 3 -0.20 2 -0.63 2 -0.34 Receptor Ingestion Rate of receptor 1 12 0.02 11 0.02 13 0.02 13 0.01 Air fraction of 1 2 0.29 2 0.22 3 0.55 3 0.28 Release time of 1 1 0.65 1 0.62 1 0.88 1 0.79 Air fraction of 2 7 0.06 7 0.04 4 0.15 4 0.07 Release time of 2 10 -0.03 10 -0.02 10 -0.04 10 -0.02

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 27 of 55 Air fraction of 3 14 0.01 14 0.01 5 0.08 7 0.03 Release time of 3 4 -0.11 4 -0.08 9 -0.05 9 -0.02 Air fraction of 4 15 0.00 15 0.00 12 -0.03 12 -0.01 Release time of 4 11 -0.02 12 -0.02 16 0.01 16 0.01 Air fraction of 5 13 0.02 13 0.02 15 -0.01 15 -0.01 Release time of 5 8 0.05 9 0.03 6 0.07 8 0.03 Air fraction of 6 5 -0.08 5 -0.06 11 -0.03 11 -0.01 Release time of 6 6 -0.07 6 -0.05 14 -0.02 14 -0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 17:03:33 Page: 38 **

Title : OCS SA_Co60 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(2) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 15 -0.02 15 -0.02 16 0.00 15 0.00 Resuspension Rate 14 -0.02 12 -0.03 9 -0.03 4 -0.03 Building Exchange Rate 2 -0.28 2 -0.27 1 -0.76 1 -0.60 Receptor Ingestion Rate of receptor 1 8 0.06 8 0.05 11 0.01 11 0.01 Air fraction of 1 16 0.01 16 0.01 8 -0.03 9 -0.02 Release time of 1 13 -0.03 14 -0.02 7 -0.03 8 -0.02 Air fraction of 2 1 0.29 1 0.27 2 0.69 2 0.49 Release time of 2 3 0.09 3 0.08 3 0.61 3 0.39 Air fraction of 3 5 0.07 5 0.06 5 0.06 6 0.03 Release time of 3 11 -0.04 11 -0.04 10 -0.02 10 -0.01 Air fraction of 4 4 0.07 4 0.06 6 0.05 7 0.03 Release time of 4 9 -0.06 9 -0.05 14 -0.01 14 -0.01 Air fraction of 5 10 -0.05 10 -0.04 12 0.01 12 0.01 Release time of 5 12 -0.03 13 -0.03 13 0.01 13 0.01 Air fraction of 6 7 0.06 7 0.05 15 0.01 16 0.00 Release time of 6 6 -0.06 6 -0.06 4 0.06 5 0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 17:03:33 Page: 39 **

Title : OCS SA_Co60 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.12 3 0.17 5 0.14 4 0.15 Resuspension Rate 5 -0.12 4 -0.16 6 -0.12 5 -0.14 Building Exchange Rate 2 -0.36 2 -0.33 1 -0.77 1 -0.58 Receptor Ingestion Rate of receptor 1 9 0.06 9 0.05 12 -0.03 12 -0.01 Air fraction of 1 10 0.05 10 0.04 9 0.07 9 0.03 Release time of 1 16 -0.01 16 0.00 7 -0.09 7 -0.04 Air fraction of 2 12 0.02 12 0.02 10 -0.07 10 -0.03 Release time of 2 15 -0.01 15 -0.01 8 -0.08 8 -0.04 Air fraction of 3 1 0.43 1 0.40 2 0.70 2 0.48 Release time of 3 3 0.15 5 0.12 3 0.67 3 0.44 Air fraction of 4 8 0.07 8 0.06 4 0.14 6 0.07 Release time of 4 14 -0.01 14 -0.01 14 0.01 14 0.01 Air fraction of 5 13 0.02 13 0.02 11 0.04 11 0.02 Release time of 5 11 0.05 11 0.04 16 0.00 16 0.00 Air fraction of 6 6 0.11 6 0.09 15 -0.01 15 0.00 Release time of 6 7 -0.09 7 -0.07 13 0.02 13 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 17:03:33 Page: 40 **

Title : OCS SA_Co60 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 9 0.05 9 0.06 5 0.13 5 0.15 Resuspension Rate 8 -0.06 5 -0.09 4 -0.16 4 -0.19 Building Exchange Rate 2 -0.29 2 -0.26 1 -0.77 1 -0.60 Receptor Ingestion Rate of receptor 1 3 0.18 3 0.16 6 0.09 6 0.05 Air fraction of 1 14 0.02 14 0.01 10 0.03 10 0.01 Release time of 1 13 0.02 13 0.02 12 -0.02 12 -0.01 Air fraction of 2 15 -0.01 15 -0.01 8 0.06 8 0.03 Release time of 2 10 0.04 10 0.03 16 0.00 16 0.00 Air fraction of 3 6 0.10 7 0.08 9 0.03 9 0.02 Release time of 3 16 -0.01 16 -0.01 14 -0.01 14 0.00 Air fraction of 4 1 0.41 1 0.39 2 0.71 2 0.50 Release time of 4 7 0.08 8 0.07 3 0.58 3 0.35 Air fraction of 5 11 -0.03 11 -0.02 13 0.01 13 0.01 Release time of 5 12 -0.02 12 -0.02 11 -0.02 11 -0.01 Air fraction of 6 4 0.15 4 0.13 7 0.08 7 0.04 Release time of 6 5 -0.10 6 -0.08 15 0.01 15 0.00

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 17:03:33 Page: 41 **

Title : OCS SA_Co60 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 28 of 55 Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 8 0.04 6 0.06 4 0.18 4 0.20 Resuspension Rate 7 -0.05 5 -0.07 5 -0.15 5 -0.16 Building Exchange Rate 2 -0.30 2 -0.27 1 -0.78 1 -0.60 Receptor Ingestion Rate of receptor 1 12 0.03 12 0.03 15 0.00 15 0.00 Air fraction of 1 16 0.01 16 0.01 12 0.03 12 0.02 Release time of 1 4 0.09 4 0.08 11 -0.04 11 -0.02 Air fraction of 2 15 0.01 14 0.01 9 0.05 9 0.02 Release time of 2 6 -0.05 8 -0.04 16 0.00 16 0.00 Air fraction of 3 9 0.04 9 0.03 7 0.10 7 0.05 Release time of 3 14 -0.01 15 -0.01 6 -0.13 6 -0.06 Air fraction of 4 10 0.04 10 0.03 8 0.10 8 0.05 Release time of 4 11 -0.04 11 -0.03 13 -0.02 13 -0.01 Air fraction of 5 1 0.43 1 0.41 2 0.75 2 0.54 Release time of 5 3 0.21 3 0.18 3 0.62 3 0.37 Air fraction of 6 13 -0.03 13 -0.02 14 0.01 14 0.01 Release time of 6 5 -0.05 7 -0.05 10 0.04 10 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 17:03:33 Page: 42 **

Title : OCS SA_Co60 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 12 0.02 11 0.04 7 0.08 5 0.09 Resuspension Rate 10 -0.04 5 -0.06 5 -0.09 4 -0.10 Building Exchange Rate 2 -0.18 2 -0.17 2 -0.69 2 -0.48 Receptor Ingestion Rate of receptor 1 16 0.01 16 0.01 6 0.08 7 0.04 Air fraction of 1 11 0.03 12 0.03 11 0.04 11 0.02 Release time of 1 4 0.07 4 0.06 12 -0.03 12 -0.02 Air fraction of 2 3 0.09 3 0.09 10 0.04 10 0.02 Release time of 2 13 0.02 13 0.02 13 -0.03 13 -0.01 Air fraction of 3 6 0.05 7 0.05 15 0.02 15 0.01 Release time of 3 14 -0.02 14 -0.02 9 0.04 9 0.02 Air fraction of 4 9 -0.04 10 -0.04 4 0.09 6 0.04 Release time of 4 7 -0.05 8 -0.05 14 0.02 14 0.01 Air fraction of 5 8 -0.04 9 -0.04 16 0.01 16 0.01 Release time of 5 15 0.02 15 0.02 8 0.05 8 0.03 Air fraction of 6 1 0.22 1 0.22 3 0.60 3 0.38 Release time of 6 5 0.05 6 0.05 1 0.76 1 0.59 Cs-137 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 17:23:00 Page: 37 **

Title : OCS SA_Cs137 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 16 0.00 16 0.00 5 0.28 3 0.26 Resuspension Rate 14 -0.01 12 -0.01 4 -0.35 2 -0.34 Building Exchange Rate 3 -0.16 3 -0.13 2 -0.52 4 -0.24 Receptor Ingestion Rate of receptor 1 7 0.05 7 0.04 6 0.16 6 0.07 Air fraction of 1 2 0.19 2 0.15 3 0.47 5 0.21 Release time of 1 1 0.56 1 0.54 1 0.90 1 0.84 Air fraction of 2 4 0.12 4 0.09 8 0.08 8 0.03 Release time of 2 9 -0.05 10 -0.04 15 0.01 15 0.00 Air fraction of 3 12 0.02 13 0.01 12 0.03 12 0.01 Release time of 3 5 -0.10 5 -0.08 11 -0.03 11 -0.01 Air fraction of 4 13 -0.01 14 -0.01 16 0.01 16 0.00 Release time of 4 8 -0.05 8 -0.04 10 -0.05 10 -0.02 Air fraction of 5 6 -0.07 6 -0.06 7 -0.11 7 -0.04 Release time of 5 10 0.05 9 0.04 14 0.01 14 0.00 Air fraction of 6 11 -0.04 11 -0.04 9 0.05 9 0.02 Release time of 6 15 0.00 15 0.00 13 0.01 13 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 17:23:00 Page: 38 **

Title : OCS SA_Cs137 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(2) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 11 -0.03 7 -0.04 5 0.37 3 0.43 Resuspension Rate 9 -0.03 6 -0.05 4 -0.46 2 -0.55 Building Exchange Rate 3 -0.19 3 -0.17 2 -0.58 4 -0.34 Receptor Ingestion Rate of receptor 1 12 0.03 12 0.02 6 0.19 6 0.09 Air fraction of 1 7 -0.04 9 -0.03 8 -0.05 8 -0.02 Release time of 1 14 0.02 14 0.02 11 0.03 11 0.02 Air fraction of 2 2 0.25 2 0.23 3 0.51 5 0.28 Release time of 2 1 0.43 1 0.40 1 0.83 1 0.70 Air fraction of 3 5 0.06 5 0.05 9 -0.04 9 -0.02 Release time of 3 13 -0.03 13 -0.02 16 -0.01 16 -0.01

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 29 of 55 Air fraction of 4 15 -0.02 15 -0.01 10 -0.04 10 -0.02 Release time of 4 10 -0.03 11 -0.03 14 0.02 14 0.01 Air fraction of 5 4 -0.15 4 -0.13 7 -0.08 7 -0.04 Release time of 5 16 0.01 16 0.01 15 -0.01 15 -0.01 Air fraction of 6 8 0.04 10 0.03 12 0.02 12 0.01 Release time of 6 6 -0.04 8 -0.04 13 0.02 13 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 17:23:00 Page: 39 **

Title : OCS SA_Cs137 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 16 0.00 15 0.01 5 0.34 3 0.37 Resuspension Rate 11 -0.05 9 -0.08 4 -0.41 2 -0.46 Building Exchange Rate 3 -0.15 3 -0.13 2 -0.56 4 -0.30 Receptor Ingestion Rate of receptor 1 5 0.12 5 0.10 6 0.17 6 0.08 Air fraction of 1 8 0.09 8 0.08 10 0.05 10 0.02 Release time of 1 14 0.03 14 0.03 9 -0.07 9 -0.03 Air fraction of 2 6 0.11 6 0.10 12 0.04 12 0.02 Release time of 2 10 0.05 11 0.05 7 -0.11 7 -0.05 Air fraction of 3 2 0.19 2 0.17 3 0.52 5 0.27 Release time of 3 1 0.40 1 0.38 1 0.86 1 0.76 Air fraction of 4 15 0.01 16 0.01 16 0.00 16 0.00 Release time of 4 12 -0.04 12 -0.03 15 0.02 15 0.01 Air fraction of 5 13 -0.04 13 -0.03 13 -0.04 13 -0.02 Release time of 5 9 0.06 10 0.05 14 0.04 14 0.02 Air fraction of 6 4 0.13 4 0.11 11 0.05 11 0.02 Release time of 6 7 -0.10 7 -0.09 8 -0.07 8 -0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 17:23:00 Page: 40 **

Title : OCS SA_Cs137 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 14 -0.01 14 -0.01 5 0.36 3 0.43 Resuspension Rate 13 -0.02 12 -0.02 4 -0.44 2 -0.55 Building Exchange Rate 4 -0.17 4 -0.15 2 -0.59 4 -0.37 Receptor Ingestion Rate of receptor 1 3 0.18 3 0.16 6 0.25 6 0.13 Air fraction of 1 10 0.05 10 0.04 13 0.02 13 0.01 Release time of 1 11 0.05 11 0.04 12 -0.02 12 -0.01 Air fraction of 2 16 0.00 16 0.00 15 -0.01 15 0.00 Release time of 2 9 0.05 9 0.05 16 0.00 16 0.00 Air fraction of 3 6 0.09 6 0.07 10 -0.03 10 -0.02 Release time of 3 12 0.02 13 0.02 9 -0.05 9 -0.02 Air fraction of 4 2 0.25 2 0.22 3 0.48 5 0.27 Release time of 4 1 0.43 1 0.40 1 0.80 1 0.67 Air fraction of 5 8 -0.06 8 -0.05 7 -0.10 7 -0.05 Release time of 5 15 0.01 15 0.00 14 -0.01 14 0.00 Air fraction of 6 5 0.10 5 0.09 8 0.09 8 0.05 Release time of 6 7 -0.09 7 -0.07 11 -0.03 11 -0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 17:23:00 Page: 41 **

Title : OCS SA_Cs137 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 11 -0.04 7 -0.05 5 0.42 3 0.49 Resuspension Rate 15 -0.01 14 -0.02 4 -0.47 2 -0.56 Building Exchange Rate 3 -0.18 3 -0.15 2 -0.61 4 -0.36 Receptor Ingestion Rate of receptor 1 5 0.09 5 0.08 6 0.21 6 0.10 Air fraction of 1 14 -0.02 15 -0.01 14 0.02 14 0.01 Release time of 1 6 0.07 6 0.06 9 -0.06 9 -0.03 Air fraction of 2 10 0.04 11 0.03 12 0.04 12 0.02 Release time of 2 7 -0.05 8 -0.05 11 -0.04 11 -0.02 Air fraction of 3 9 0.04 10 0.03 7 0.09 7 0.04 Release time of 3 8 0.05 9 0.04 15 -0.01 15 0.00 Air fraction of 4 16 0.01 16 0.01 16 0.00 16 0.00 Release time of 4 12 -0.03 13 -0.02 8 -0.08 8 -0.04 Air fraction of 5 2 0.29 2 0.25 3 0.51 5 0.27 Release time of 5 1 0.50 1 0.48 1 0.85 1 0.73 Air fraction of 6 13 -0.03 12 -0.02 13 0.03 13 0.01 Release time of 6 4 -0.10 4 -0.09 10 -0.06 10 -0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 17:23:00 Page: 42 **

Title : OCS SA_Cs137 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 30 of 55 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 12 0.02 12 0.04 5 0.32 3 0.35 Resuspension Rate 6 -0.05 3 -0.09 4 -0.41 2 -0.47 Building Exchange Rate 3 -0.08 4 -0.08 2 -0.57 4 -0.32 Receptor Ingestion Rate of receptor 1 14 -0.02 14 -0.02 6 0.20 6 0.09 Air fraction of 1 9 0.05 9 0.04 12 -0.02 12 -0.01 Release time of 1 4 0.08 5 0.08 14 0.01 14 0.00 Air fraction of 2 2 0.09 2 0.09 15 0.00 15 0.00 Release time of 2 11 0.04 11 0.04 16 0.00 16 0.00 Air fraction of 3 8 0.05 8 0.05 7 0.06 7 0.03 Release time of 3 15 -0.02 15 -0.02 11 -0.03 11 -0.01 Air fraction of 4 5 -0.07 6 -0.07 10 0.03 10 0.01 Release time of 4 7 -0.05 7 -0.05 9 -0.05 9 -0.02 Air fraction of 5 10 -0.04 10 -0.04 13 -0.01 13 0.00 Release time of 5 13 0.02 13 0.02 8 0.05 8 0.02 Air fraction of 6 1 0.12 1 0.12 3 0.50 5 0.27 Release time of 6 16 0.00 16 0.00 1 0.85 1 0.75 Eu-152 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 17:39:33 Page: 37 **

Title : OCS SA_Eu152 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 10 0.03 8 0.04 5 0.10 5 0.11 Resuspension Rate 13 -0.01 11 -0.01 4 -0.11 4 -0.11 Building Exchange Rate 2 -0.34 2 -0.31 1 -0.76 1 -0.55 Receptor Ingestion Rate of receptor 1 11 0.01 12 0.01 13 -0.02 13 -0.01 Air fraction of 1 1 0.35 1 0.32 3 0.70 3 0.47 Release time of 1 3 0.25 3 0.22 2 0.73 2 0.51 Air fraction of 2 14 0.01 14 0.01 15 0.00 15 0.00 Release time of 2 7 0.05 7 0.04 11 -0.03 11 -0.01 Air fraction of 3 16 0.01 16 0.00 10 0.03 10 0.01 Release time of 3 5 -0.05 5 -0.04 6 -0.09 6 -0.04 Air fraction of 4 8 -0.04 9 -0.03 16 0.00 16 0.00 Release time of 4 4 -0.05 4 -0.05 14 -0.01 14 0.00 Air fraction of 5 9 0.03 10 0.03 12 0.03 12 0.01 Release time of 5 12 -0.01 13 -0.01 9 0.03 9 0.01 Air fraction of 6 15 -0.01 15 -0.01 7 0.04 7 0.02 Release time of 6 6 -0.05 6 -0.04 8 0.04 8 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 17:39:33 Page: 38 **

Title : OCS SA_Eu152 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(2) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 14 -0.02 13 -0.03 15 0.03 10 0.03 Resuspension Rate 15 -0.01 15 -0.02 10 -0.05 7 -0.05 Building Exchange Rate 1 -0.29 1 -0.27 1 -0.83 1 -0.67 Receptor Ingestion Rate of receptor 1 5 0.07 5 0.07 11 0.04 12 0.02 Air fraction of 1 13 0.03 14 0.03 3 -0.14 3 -0.06 Release time of 1 8 -0.06 8 -0.06 14 -0.03 15 -0.01 Air fraction of 2 2 0.27 2 0.26 2 0.79 2 0.58 Release time of 2 3 -0.18 3 -0.16 8 0.06 9 0.03 Air fraction of 3 9 0.06 9 0.05 6 0.12 6 0.05 Release time of 3 10 -0.06 10 -0.05 9 -0.05 11 -0.02 Air fraction of 4 6 0.07 6 0.06 12 -0.04 13 -0.02 Release time of 4 11 -0.05 11 -0.05 5 -0.13 5 -0.06 Air fraction of 5 16 0.00 16 0.00 7 0.07 8 0.03 Release time of 5 12 -0.05 12 -0.04 13 0.03 14 0.02 Air fraction of 6 4 0.08 4 0.07 16 -0.01 16 0.00 Release time of 6 7 -0.07 7 -0.06 4 0.13 4 0.06

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 17:39:33 Page: 39 **

Title : OCS SA_Eu152 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.12 4 0.17 3 0.12 3 0.12 Resuspension Rate 5 -0.11 5 -0.15 7 -0.09 4 -0.09 Building Exchange Rate 2 -0.40 2 -0.36 1 -0.86 1 -0.70 Receptor Ingestion Rate of receptor 1 10 0.04 10 0.03 4 -0.12 5 -0.05 Air fraction of 1 7 0.06 7 0.05 14 -0.04 14 -0.02 Release time of 1 12 -0.03 12 -0.02 11 -0.07 11 -0.03 Air fraction of 2 14 -0.01 14 -0.01 5 -0.12 6 -0.05 Release time of 2 16 0.00 16 0.00 12 -0.06 12 -0.03 Air fraction of 3 1 0.43 1 0.39 2 0.80 2 0.56 Release time of 3 3 -0.25 3 -0.21 9 -0.08 9 -0.03 Air fraction of 4 9 0.05 9 0.04 15 0.04 15 0.02

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 31 of 55 Release time of 4 15 0.00 15 0.00 6 0.11 7 0.05 Air fraction of 5 13 0.02 13 0.02 8 0.09 8 0.04 Release time of 5 11 0.03 11 0.03 16 -0.02 16 -0.01 Air fraction of 6 8 0.06 8 0.05 13 0.06 13 0.02 Release time of 6 6 -0.08 6 -0.06 10 0.07 10 0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 17:39:33 Page: 40 **

Title : OCS SA_Eu152 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 9 0.04 9 0.06 5 0.14 4 0.14 Resuspension Rate 8 -0.07 6 -0.10 3 -0.19 3 -0.19 Building Exchange Rate 2 -0.32 2 -0.28 1 -0.83 1 -0.64 Receptor Ingestion Rate of receptor 1 5 0.16 5 0.14 9 0.05 9 0.02 Air fraction of 1 16 0.01 16 0.00 15 0.00 15 0.00 Release time of 1 15 -0.01 15 -0.01 16 0.00 16 0.00 Air fraction of 2 14 -0.01 14 -0.01 6 0.09 6 0.04 Release time of 2 11 0.03 11 0.03 7 0.09 7 0.04 Air fraction of 3 6 0.09 7 0.08 12 0.01 12 0.00 Release time of 3 10 -0.03 10 -0.03 13 -0.01 13 0.00 Air fraction of 4 1 0.43 1 0.40 2 0.82 2 0.62 Release time of 4 3 -0.22 3 -0.19 10 -0.03 10 -0.01 Air fraction of 5 13 -0.02 13 -0.02 8 -0.06 8 -0.03 Release time of 5 12 -0.03 12 -0.02 14 0.01 14 0.00 Air fraction of 6 4 0.17 4 0.14 4 0.15 5 0.07 Release time of 6 7 -0.08 8 -0.07 11 0.02 11 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 17:39:33 Page: 41 **

Title : OCS SA_Eu152 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 5 0.07 4 0.09 3 0.25 3 0.25 Resuspension Rate 6 -0.06 5 -0.09 4 -0.22 4 -0.22 Building Exchange Rate 2 -0.34 2 -0.31 1 -0.83 1 -0.64 Receptor Ingestion Rate of receptor 1 12 0.02 12 0.02 15 -0.02 15 -0.01 Air fraction of 1 15 0.01 15 0.01 16 0.01 16 0.01 Release time of 1 4 0.07 6 0.06 13 0.03 13 0.01 Air fraction of 2 16 0.01 16 0.01 6 0.10 6 0.05 Release time of 2 8 -0.05 8 -0.05 10 -0.05 10 -0.02 Air fraction of 3 10 0.04 10 0.03 12 0.03 12 0.01 Release time of 3 7 -0.05 7 -0.05 8 -0.07 8 -0.03 Air fraction of 4 11 0.03 11 0.02 14 0.02 14 0.01 Release time of 4 13 -0.02 13 -0.02 9 -0.06 9 -0.03 Air fraction of 5 1 0.44 1 0.41 2 0.82 2 0.63 Release time of 5 3 -0.14 3 -0.12 5 0.15 5 0.07 Air fraction of 6 14 -0.01 14 -0.01 7 0.09 7 0.04 Release time of 6 9 -0.04 9 -0.03 11 0.04 11 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 17:39:33 Page: 42 **

Title : OCS SA_Eu152 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 14 0.00 14 0.01 4 0.09 4 0.09 Resuspension Rate 13 -0.01 13 -0.01 5 -0.09 5 -0.09 Building Exchange Rate 2 -0.18 2 -0.17 1 -0.82 1 -0.65 Receptor Ingestion Rate of receptor 1 15 0.00 15 0.00 9 0.05 9 0.02 Air fraction of 1 12 0.02 12 0.02 15 0.02 15 0.01 Release time of 1 5 0.07 5 0.06 6 0.07 6 0.03 Air fraction of 2 4 0.08 4 0.07 12 -0.04 12 -0.02 Release time of 2 11 0.02 11 0.02 11 0.04 11 0.02 Air fraction of 3 7 0.05 7 0.05 16 -0.01 16 0.00 Release time of 3 10 -0.04 10 -0.04 14 0.03 14 0.01 Air fraction of 4 8 -0.04 8 -0.04 7 0.06 7 0.03 Release time of 4 6 -0.05 6 -0.05 10 -0.05 10 -0.02 Air fraction of 5 9 -0.04 9 -0.04 8 -0.06 8 -0.03 Release time of 5 16 0.00 16 0.00 13 -0.03 13 -0.01 Air fraction of 6 1 0.23 1 0.22 2 0.77 2 0.55 Release time of 6 3 -0.12 3 -0.11 3 0.52 3 0.27 Eu-154 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:01:52 Page: 37 **

Title : OCS SA_Eu154 Input File : C:\RESRAD_Family\BUILD\3.BLD

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 32 of 55 Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 10 0.02 7 0.03 5 0.08 5 0.09 Resuspension Rate 14 -0.01 12 -0.01 4 -0.09 4 -0.10 Building Exchange Rate 2 -0.33 2 -0.31 1 -0.78 1 -0.58 Receptor Ingestion Rate of receptor 1 12 0.01 13 0.01 12 -0.02 12 -0.01 Air fraction of 1 1 0.34 1 0.32 2 0.73 2 0.49 Release time of 1 3 0.14 3 0.13 3 0.69 3 0.44 Air fraction of 2 13 -0.01 14 -0.01 11 -0.03 11 -0.01 Release time of 2 4 0.06 4 0.05 9 -0.04 9 -0.02 Air fraction of 3 15 0.00 15 0.00 15 0.01 15 0.01 Release time of 3 8 -0.04 9 -0.03 6 -0.07 6 -0.03 Air fraction of 4 9 -0.03 10 -0.03 16 0.01 16 0.00 Release time of 4 5 -0.05 5 -0.04 14 0.02 14 0.01 Air fraction of 5 7 0.04 8 0.03 10 0.03 10 0.01 Release time of 5 11 -0.02 11 -0.02 13 0.02 13 0.01 Air fraction of 6 16 0.00 16 0.00 7 0.06 7 0.03 Release time of 6 6 -0.05 6 -0.04 8 0.04 8 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:01:52 Page: 38 **

Title : OCS SA_Eu154 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(2) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 14 -0.02 14 -0.03 14 0.03 9 0.03 Resuspension Rate 15 -0.01 15 -0.02 10 -0.05 6 -0.05 Building Exchange Rate 1 -0.28 1 -0.27 1 -0.83 1 -0.65 Receptor Ingestion Rate of receptor 1 4 0.08 4 0.07 15 0.02 15 0.01 Air fraction of 1 13 0.03 13 0.03 5 -0.14 5 -0.06 Release time of 1 8 -0.06 8 -0.06 12 -0.04 13 -0.02 Air fraction of 2 2 0.27 2 0.25 2 0.81 2 0.61 Release time of 2 3 -0.20 3 -0.19 13 -0.04 14 -0.02 Air fraction of 3 9 0.06 9 0.06 4 0.14 4 0.06 Release time of 3 10 -0.05 10 -0.05 9 -0.06 11 -0.02 Air fraction of 4 6 0.07 6 0.06 8 -0.07 10 -0.03 Release time of 4 11 -0.05 11 -0.05 3 -0.15 3 -0.07 Air fraction of 5 16 0.01 16 0.01 7 0.08 8 0.04 Release time of 5 12 -0.05 12 -0.04 11 0.04 12 0.02 Air fraction of 6 5 0.08 5 0.07 16 0.00 16 0.00 Release time of 6 7 -0.07 7 -0.06 6 0.11 7 0.05

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:01:52 Page: 39 **

Title : OCS SA_Eu154 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.13 4 0.17 6 0.09 3 0.09 Resuspension Rate 5 -0.11 5 -0.15 12 -0.06 5 -0.05 Building Exchange Rate 2 -0.39 2 -0.35 1 -0.86 1 -0.70 Receptor Ingestion Rate of receptor 1 10 0.04 10 0.03 4 -0.12 6 -0.05 Air fraction of 1 8 0.05 8 0.04 14 -0.03 14 -0.01 Release time of 1 11 -0.04 11 -0.03 9 -0.07 10 -0.03 Air fraction of 2 15 -0.01 15 -0.01 10 -0.07 11 -0.03 Release time of 2 16 -0.01 16 0.00 11 -0.06 12 -0.03 Air fraction of 3 1 0.43 1 0.39 2 0.80 2 0.56 Release time of 3 3 -0.28 3 -0.24 3 -0.17 4 -0.07 Air fraction of 4 7 0.06 7 0.05 15 0.02 15 0.01 Release time of 4 14 0.01 14 0.01 5 0.11 7 0.05 Air fraction of 5 13 0.03 13 0.02 7 0.09 8 0.04 Release time of 5 12 0.03 12 0.03 16 0.00 16 0.00 Air fraction of 6 9 0.04 9 0.04 8 0.07 9 0.03 Release time of 6 6 -0.07 6 -0.06 13 0.05 13 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:01:52 Page: 40 **

Title : OCS SA_Eu154 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 9 0.04 9 0.05 5 0.13 4 0.12 Resuspension Rate 8 -0.07 6 -0.10 3 -0.17 3 -0.16 Building Exchange Rate 2 -0.32 2 -0.28 1 -0.84 1 -0.65 Receptor Ingestion Rate of receptor 1 4 0.16 4 0.14 10 0.05 10 0.02 Air fraction of 1 16 0.00 16 0.00 12 -0.02 12 -0.01 Release time of 1 15 -0.01 15 -0.01 11 -0.04 11 -0.02 Air fraction of 2 14 -0.02 14 -0.01 9 0.06 9 0.03 Release time of 2 11 0.03 12 0.02 8 0.10 8 0.04 Air fraction of 3 6 0.09 7 0.07 14 -0.02 14 -0.01 Release time of 3 10 -0.03 10 -0.03 16 0.00 16 0.00 Air fraction of 4 1 0.43 1 0.40 2 0.83 2 0.62

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 33 of 55 Release time of 4 3 -0.24 3 -0.21 6 -0.12 6 -0.05 Air fraction of 5 13 -0.02 13 -0.02 7 -0.11 7 -0.05 Release time of 5 12 -0.03 11 -0.02 15 0.01 15 0.00 Air fraction of 6 5 0.16 5 0.14 4 0.15 5 0.07 Release time of 6 7 -0.08 8 -0.06 13 0.02 13 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:01:52 Page: 41 **

Title : OCS SA_Eu154 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.07 4 0.10 3 0.23 3 0.22 Resuspension Rate 6 -0.06 5 -0.09 4 -0.20 4 -0.19 Building Exchange Rate 2 -0.34 2 -0.31 1 -0.84 1 -0.65 Receptor Ingestion Rate of receptor 1 13 0.02 13 0.01 13 -0.03 13 -0.01 Air fraction of 1 14 0.01 14 0.01 16 0.00 16 0.00 Release time of 1 5 0.07 6 0.06 11 0.04 11 0.02 Air fraction of 2 16 0.00 16 0.00 8 0.06 8 0.02 Release time of 2 8 -0.05 8 -0.04 9 -0.06 9 -0.02 Air fraction of 3 9 0.03 9 0.03 14 0.02 14 0.01 Release time of 3 7 -0.05 7 -0.05 12 -0.03 12 -0.01 Air fraction of 4 10 0.03 10 0.03 15 0.02 15 0.01 Release time of 4 12 -0.02 12 -0.01 10 -0.05 10 -0.02 Air fraction of 5 1 0.43 1 0.41 2 0.83 2 0.63 Release time of 5 3 -0.17 3 -0.15 6 0.08 6 0.03 Air fraction of 6 15 -0.01 15 -0.01 5 0.10 5 0.04 Release time of 6 11 -0.03 11 -0.02 7 0.07 7 0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:01:52 Page: 42 **

Title : OCS SA_Eu154 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 16 0.00 16 0.00 8 0.05 4 0.05 Resuspension Rate 15 0.01 13 0.01 13 -0.04 6 -0.04 Building Exchange Rate 2 -0.21 2 -0.20 1 -0.83 1 -0.66 Receptor Ingestion Rate of receptor 1 12 0.02 12 0.02 7 0.05 9 0.02 Air fraction of 1 13 0.01 14 0.01 12 0.04 13 0.02 Release time of 1 5 0.06 5 0.06 4 0.10 5 0.04 Air fraction of 2 4 0.07 4 0.06 10 -0.04 11 -0.02 Release time of 2 11 0.02 11 0.02 9 0.05 10 0.02 Air fraction of 3 7 0.05 7 0.05 16 -0.03 16 -0.01 Release time of 3 8 -0.04 8 -0.04 15 0.03 15 0.01 Air fraction of 4 10 -0.03 10 -0.03 6 0.06 8 0.03 Release time of 4 6 -0.05 6 -0.05 5 -0.07 7 -0.03 Air fraction of 5 9 -0.04 9 -0.04 14 -0.04 14 -0.02 Release time of 5 14 -0.01 15 -0.01 11 -0.04 12 -0.02 Air fraction of 6 1 0.26 1 0.25 2 0.79 2 0.57 Release time of 6 3 -0.14 3 -0.14 3 0.40 3 0.19 Fe-55 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:25:50 Page: 37 **

Title : OCS SA_Fe55 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 13 0.01 13 0.02 15 0.00 14 0.00 Resuspension Rate 14 -0.01 14 -0.01 16 0.00 15 0.00 Building Exchange Rate 2 -0.28 2 -0.27 1 -0.85 1 -0.67 Receptor Ingestion Rate of receptor 1 12 0.02 12 0.02 4 0.09 4 0.04 Air fraction of 1 1 0.30 1 0.28 2 0.83 2 0.62 Release time of 1 3 -0.18 3 -0.17 3 0.15 3 0.06 Air fraction of 2 7 -0.04 7 -0.04 5 -0.08 5 -0.03 Release time of 2 4 0.08 4 0.07 11 -0.04 11 -0.02 Air fraction of 3 15 0.00 15 0.00 13 -0.01 13 0.00 Release time of 3 16 0.00 16 0.00 14 0.01 16 0.00 Air fraction of 4 9 -0.03 9 -0.03 8 0.05 8 0.02 Release time of 4 6 -0.04 6 -0.04 9 0.05 9 0.02 Air fraction of 5 5 0.05 5 0.05 7 0.06 7 0.02 Release time of 5 8 -0.04 8 -0.03 12 0.02 12 0.01 Air fraction of 6 11 0.02 11 0.02 6 0.07 6 0.03 Release time of 6 10 -0.03 10 -0.03 10 0.04 10 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:25:50 Page: 38 **

Title : OCS SA_Fe55 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(2) at Time: 2

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 34 of 55 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 14 -0.02 13 -0.04 12 -0.05 7 -0.05 Resuspension Rate 16 -0.01 16 -0.01 15 0.03 13 0.03 Building Exchange Rate 1 -0.28 1 -0.27 1 -0.84 1 -0.66 Receptor Ingestion Rate of receptor 1 4 0.09 4 0.08 9 0.09 10 0.04 Air fraction of 1 13 0.03 14 0.03 8 -0.10 9 -0.04 Release time of 1 7 -0.06 7 -0.06 11 -0.07 12 -0.03 Air fraction of 2 2 0.26 2 0.25 2 0.81 2 0.60 Release time of 2 3 -0.17 3 -0.16 4 0.14 4 0.06 Air fraction of 3 9 0.06 8 0.06 6 0.12 6 0.05 Release time of 3 11 -0.05 11 -0.04 13 -0.05 14 -0.02 Air fraction of 4 5 0.08 5 0.08 10 -0.08 11 -0.03 Release time of 4 10 -0.06 10 -0.05 3 -0.15 3 -0.07 Air fraction of 5 15 0.02 15 0.01 7 0.11 8 0.05 Release time of 5 12 -0.04 12 -0.04 14 0.04 15 0.02 Air fraction of 6 6 0.07 6 0.07 16 -0.01 16 -0.01 Release time of 6 8 -0.06 9 -0.06 5 0.13 5 0.06

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:25:50 Page: 39 **

Title : OCS SA_Fe55 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.13 4 0.17 16 0.00 16 0.00 Resuspension Rate 5 -0.10 5 -0.14 11 0.05 3 0.05 Building Exchange Rate 2 -0.39 2 -0.35 1 -0.86 1 -0.70 Receptor Ingestion Rate of receptor 1 7 0.07 7 0.06 6 -0.07 7 -0.03 Air fraction of 1 9 0.05 9 0.04 12 -0.01 12 0.00 Release time of 1 10 -0.04 10 -0.04 10 -0.05 11 -0.02 Air fraction of 2 14 -0.02 14 -0.02 3 -0.11 4 -0.05 Release time of 2 16 -0.01 16 -0.01 9 -0.06 10 -0.03 Air fraction of 3 1 0.43 1 0.40 2 0.81 2 0.58 Release time of 3 3 -0.24 3 -0.20 14 0.00 14 0.00 Air fraction of 4 6 0.07 6 0.06 13 0.01 13 0.00 Release time of 4 15 0.01 15 0.01 4 0.10 5 0.04 Air fraction of 5 12 0.04 12 0.03 5 0.08 6 0.03 Release time of 5 13 0.03 13 0.03 15 0.00 15 0.00 Air fraction of 6 11 0.04 11 0.03 8 0.07 9 0.03 Release time of 6 8 -0.06 8 -0.05 7 0.07 8 0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:25:50 Page: 40 **

Title : OCS SA_Fe55 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 11 0.03 9 0.04 9 0.05 5 0.05 Resuspension Rate 8 -0.06 6 -0.08 6 -0.09 3 -0.09 Building Exchange Rate 2 -0.31 2 -0.28 1 -0.84 1 -0.65 Receptor Ingestion Rate of receptor 1 4 0.18 4 0.15 5 0.09 7 0.04 Air fraction of 1 16 0.00 16 0.00 16 0.00 16 0.00 Release time of 1 15 -0.01 15 -0.01 13 -0.02 13 -0.01 Air fraction of 2 13 -0.02 13 -0.02 8 0.07 9 0.03 Release time of 2 12 0.03 12 0.02 7 0.08 8 0.03 Air fraction of 3 6 0.08 7 0.07 14 -0.02 14 -0.01 Release time of 3 9 -0.03 10 -0.03 12 0.03 12 0.01 Air fraction of 4 1 0.43 1 0.40 2 0.83 2 0.63 Release time of 4 3 -0.20 3 -0.17 10 0.05 10 0.02 Air fraction of 5 14 -0.02 14 -0.01 4 -0.09 6 -0.04 Release time of 5 10 -0.03 11 -0.02 15 -0.01 15 0.00 Air fraction of 6 5 0.16 5 0.13 3 0.14 4 0.06 Release time of 6 7 -0.08 8 -0.06 11 0.03 11 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:25:50 Page: 41 **

Title : OCS SA_Fe55 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 5 0.07 4 0.09 4 0.17 3 0.16 Resuspension Rate 6 -0.06 5 -0.08 5 -0.12 4 -0.11 Building Exchange Rate 2 -0.34 2 -0.31 1 -0.85 1 -0.65 Receptor Ingestion Rate of receptor 1 10 0.04 10 0.03 13 0.02 13 0.01 Air fraction of 1 15 0.02 15 0.01 14 0.01 14 0.00 Release time of 1 4 0.07 6 0.06 15 0.01 15 0.00 Air fraction of 2 16 0.00 16 0.00 6 0.07 6 0.03 Release time of 2 7 -0.06 7 -0.05 7 -0.07 7 -0.03 Air fraction of 3 12 0.03 12 0.02 16 0.00 16 0.00 Release time of 3 8 -0.05 8 -0.04 12 -0.05 12 -0.02 Air fraction of 4 9 0.04 9 0.03 10 0.06 10 0.02 Release time of 4 13 -0.02 13 -0.02 11 -0.05 11 -0.02 Air fraction of 5 1 0.44 1 0.42 2 0.84 2 0.64

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 35 of 55 Release time of 5 3 -0.12 3 -0.10 3 0.21 5 0.09 Air fraction of 6 14 -0.02 14 -0.01 9 0.07 9 0.03 Release time of 6 11 -0.03 11 -0.03 8 0.07 8 0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:25:50 Page: 42 **

Title : OCS SA_Fe55 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 13 -0.02 11 -0.03 12 -0.03 9 -0.03 Resuspension Rate 6 0.05 4 0.07 9 0.05 5 0.04 Building Exchange Rate 2 -0.28 2 -0.26 1 -0.85 1 -0.68 Receptor Ingestion Rate of receptor 1 4 0.06 5 0.05 5 0.09 6 0.04 Air fraction of 1 14 -0.01 14 -0.01 8 0.05 10 0.02 Release time of 1 10 0.04 10 0.03 3 0.11 3 0.04 Air fraction of 2 8 0.05 8 0.04 15 -0.02 15 -0.01 Release time of 2 15 0.00 15 0.00 13 0.03 13 0.01 Air fraction of 3 7 0.05 7 0.04 16 0.00 16 0.00 Release time of 3 5 -0.05 6 -0.05 14 0.03 14 0.01 Air fraction of 4 16 0.00 16 0.00 4 0.10 4 0.04 Release time of 4 9 -0.04 9 -0.04 10 -0.04 11 -0.02 Air fraction of 5 11 -0.04 12 -0.03 11 -0.04 12 -0.02 Release time of 5 12 -0.03 13 -0.03 7 -0.07 8 -0.03 Air fraction of 6 1 0.33 1 0.32 2 0.83 2 0.61 Release time of 6 3 -0.22 3 -0.20 6 0.09 7 0.04 H-3 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/22/22 15:28:47 Page: 37 **

Title : OCS SA_H3 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 7 0.03 6 0.05 3 0.44 3 0.38 Resuspension Rate 5 -0.04 5 -0.06 2 -0.48 2 -0.42 Building Exchange Rate 1 -0.25 1 -0.25 1 -0.93 1 -0.90 Receptor Ingestion Rate of receptor 1 4 0.07 4 0.07 5 0.22 5 0.08 Release time of 1 2 -0.25 2 -0.24 4 -0.33 4 -0.13 Release time of 2 3 0.08 3 0.08 9 0.01 9 0.00 Release time of 3 9 -0.01 9 -0.01 7 0.11 7 0.04 Release time of 4 8 0.03 8 0.03 10 0.01 10 0.00 Release time of 5 6 0.03 7 0.03 6 0.11 6 0.04 Release time of 6 10 -0.01 10 -0.01 8 0.01 8 0.00

    • RESRAD-BUILD Regression and Correlation output 3.50 02/22/22 15:28:47 Page: 38 **

Title : OCS SA_H3 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(2) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 5 0.03 5 0.04 3 0.38 3 0.33 Resuspension Rate 4 -0.05 4 -0.07 2 -0.46 2 -0.41 Building Exchange Rate 1 -0.39 1 -0.39 1 -0.93 1 -0.90 Receptor Ingestion Rate of receptor 1 3 0.08 3 0.08 5 0.22 5 0.08 Release time of 1 8 0.01 8 0.01 10 -0.01 10 0.00 Release time of 2 2 -0.21 2 -0.19 4 -0.22 4 -0.08 Release time of 3 10 0.00 10 0.00 6 0.11 6 0.04 Release time of 4 9 -0.01 9 -0.01 7 -0.09 7 -0.03 Release time of 5 7 -0.02 7 -0.02 8 0.04 8 0.02 Release time of 6 6 -0.02 6 -0.02 9 0.02 9 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/22/22 15:28:47 Page: 39 **

Title : OCS SA_H3 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 8 0.02 7 0.03 3 0.38 3 0.34 Resuspension Rate 5 -0.04 3 -0.07 2 -0.45 2 -0.42 Building Exchange Rate 1 -0.22 1 -0.21 1 -0.92 1 -0.90 Receptor Ingestion Rate of receptor 1 4 0.06 5 0.06 4 0.25 4 0.10 Release time of 1 10 0.01 10 0.01 7 0.02 7 0.01 Release time of 2 6 -0.04 6 -0.04 9 0.00 9 0.00 Release time of 3 2 -0.20 2 -0.19 5 -0.17 5 -0.07 Release time of 4 9 -0.01 9 -0.01 8 -0.01 8 0.00

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 36 of 55 Release time of 5 3 -0.07 4 -0.06 6 -0.07 6 -0.03 Release time of 6 7 0.02 8 0.02 10 0.00 10 0.00

    • RESRAD-BUILD Regression and Correlation output 3.50 02/22/22 15:28:47 Page: 40 **

Title : OCS SA_H3 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 10 0.00 10 0.01 3 0.43 3 0.37 Resuspension Rate 9 -0.01 9 -0.01 2 -0.49 2 -0.43 Building Exchange Rate 1 -0.22 1 -0.22 1 -0.93 1 -0.90 Receptor Ingestion Rate of receptor 1 6 0.04 6 0.04 5 0.28 5 0.10 Release time of 1 4 0.07 4 0.07 10 0.03 10 0.01 Release time of 2 5 -0.04 5 -0.04 8 -0.06 8 -0.02 Release time of 3 7 -0.04 7 -0.03 6 0.11 6 0.04 Release time of 4 2 -0.21 2 -0.21 4 -0.35 4 -0.13 Release time of 5 8 -0.02 8 -0.02 7 0.09 7 0.03 Release time of 6 3 -0.07 3 -0.07 9 0.05 9 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/22/22 15:28:47 Page: 41 **

Title : OCS SA_H3 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 5 0.06 5 0.09 3 0.40 3 0.34 Resuspension Rate 4 -0.10 3 -0.15 2 -0.49 2 -0.43 Building Exchange Rate 1 -0.37 1 -0.36 1 -0.93 1 -0.91 Receptor Ingestion Rate of receptor 1 3 0.11 4 0.10 4 0.22 4 0.08 Release time of 1 8 -0.02 8 -0.02 6 0.05 6 0.02 Release time of 2 7 0.04 7 0.03 9 0.01 9 0.00 Release time of 3 6 -0.06 6 -0.05 8 0.01 8 0.00 Release time of 4 10 0.02 10 0.02 7 -0.01 7 0.00 Release time of 5 2 -0.25 2 -0.23 5 -0.21 5 -0.08 Release time of 6 9 -0.02 9 -0.02 10 0.00 10 0.00

    • RESRAD-BUILD Regression and Correlation output 3.50 02/22/22 15:28:47 Page: 42 **

Title : OCS SA_H3 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 6 0.04 5 0.06 3 0.37 3 0.32 Resuspension Rate 4 -0.06 3 -0.09 2 -0.43 2 -0.38 Building Exchange Rate 1 -0.30 1 -0.30 1 -0.93 1 -0.91 Receptor Ingestion Rate of receptor 1 3 0.07 4 0.07 5 0.23 5 0.08 Release time of 1 10 -0.02 10 -0.02 9 -0.03 9 -0.01 Release time of 2 9 0.02 9 0.02 10 -0.01 10 -0.01 Release time of 3 8 -0.03 8 -0.03 6 0.07 6 0.02 Release time of 4 7 0.03 7 0.03 7 -0.03 7 -0.01 Release time of 5 5 0.05 6 0.05 8 0.03 8 0.01 Release time of 6 2 -0.25 2 -0.23 4 -0.29 4 -0.11 Mn-54 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:35:40 Page: 37 **

Title : OCS SA_Mn54 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 12 0.02 10 0.02 8 0.07 3 0.02 Resuspension Rate 9 0.03 8 0.03 11 -0.03 9 -0.01 Building Exchange Rate 10 -0.03 11 -0.02 2 -0.27 2 -0.04 Receptor Ingestion Rate of receptor 1 16 0.00 16 0.00 16 0.00 16 0.00 Air fraction of 1 11 0.02 12 0.02 4 0.13 5 0.02 Release time of 1 1 0.68 1 0.67 1 0.99 1 0.99 Air fraction of 2 5 0.07 5 0.05 9 0.06 10 0.01 Release time of 2 4 -0.09 4 -0.07 12 0.03 12 0.00 Air fraction of 3 15 0.01 15 0.01 6 0.09 7 0.01 Release time of 3 2 -0.10 2 -0.07 7 -0.08 8 -0.01 Air fraction of 4 8 0.04 9 0.03 15 0.00 15 0.00 Release time of 4 13 0.01 13 0.01 14 -0.01 14 0.00 Air fraction of 5 14 -0.01 14 -0.01 3 -0.14 4 -0.02 Release time of 5 6 0.06 6 0.05 13 -0.02 13 0.00 Air fraction of 6 3 -0.09 3 -0.07 5 0.12 6 0.02 Release time of 6 7 -0.05 7 -0.03 10 -0.03 11 -0.01

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 37 of 55

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:35:40 Page: 38 **

Title : OCS SA_Mn54 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(2) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 14 0.01 14 0.02 4 0.21 3 0.14 Resuspension Rate 15 -0.01 15 -0.02 5 -0.17 5 -0.11 Building Exchange Rate 9 -0.04 9 -0.03 2 -0.46 2 -0.14 Receptor Ingestion Rate of receptor 1 7 -0.05 7 -0.04 8 0.04 8 0.01 Air fraction of 1 5 -0.07 5 -0.05 11 -0.03 11 -0.01 Release time of 1 4 0.09 4 0.07 14 0.02 14 0.01 Air fraction of 2 3 0.11 3 0.08 3 0.38 4 0.11 Release time of 2 1 0.66 1 0.66 1 0.96 1 0.94 Air fraction of 3 6 0.05 6 0.04 7 -0.05 7 -0.01 Release time of 3 12 0.03 12 0.02 12 -0.03 12 -0.01 Air fraction of 4 13 0.02 13 0.02 13 0.03 13 0.01 Release time of 4 11 -0.04 11 -0.03 10 -0.03 10 -0.01 Air fraction of 5 2 -0.16 2 -0.12 9 -0.03 9 -0.01 Release time of 5 10 0.04 10 0.03 6 -0.07 6 -0.02 Air fraction of 6 8 -0.04 8 -0.03 15 0.01 15 0.00 Release time of 6 16 0.00 16 0.00 16 0.00 16 0.00

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:35:40 Page: 39 **

Title : OCS SA_Mn54 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 12 0.03 11 0.03 4 0.16 4 0.09 Resuspension Rate 10 -0.04 4 -0.05 7 -0.10 5 -0.06 Building Exchange Rate 15 0.00 15 0.00 2 -0.50 2 -0.15 Receptor Ingestion Rate of receptor 1 6 0.06 7 0.04 12 0.04 12 0.01 Air fraction of 1 16 0.00 16 0.00 6 0.13 7 0.03 Release time of 1 8 0.05 9 0.04 11 0.04 11 0.01 Air fraction of 2 7 0.05 8 0.04 9 0.08 9 0.02 Release time of 2 13 -0.02 13 -0.02 10 -0.07 10 -0.02 Air fraction of 3 3 0.10 3 0.07 3 0.40 3 0.11 Release time of 3 1 0.66 1 0.66 1 0.96 1 0.94 Air fraction of 4 4 0.06 5 0.05 14 -0.03 14 -0.01 Release time of 4 11 -0.04 12 -0.03 15 -0.02 15 -0.01 Air fraction of 5 14 0.02 14 0.01 13 -0.03 13 -0.01 Release time of 5 5 0.06 6 0.04 16 0.00 16 0.00 Air fraction of 6 2 0.15 2 0.11 8 0.09 8 0.02 Release time of 6 9 -0.05 10 -0.03 5 -0.13 6 -0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:35:40 Page: 40 **

Title : OCS SA_Mn54 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 14 0.01 13 0.01 4 0.13 4 0.06 Resuspension Rate 8 0.03 7 0.03 5 -0.12 5 -0.05 Building Exchange Rate 15 0.00 15 0.00 2 -0.47 2 -0.10 Receptor Ingestion Rate of receptor 1 3 0.09 3 0.07 7 0.07 7 0.01 Air fraction of 1 7 0.04 8 0.03 11 0.03 11 0.01 Release time of 1 2 0.09 2 0.07 12 0.03 12 0.01 Air fraction of 2 13 0.01 14 0.01 14 -0.03 14 0.00 Release time of 2 10 0.02 10 0.01 9 -0.06 9 -0.01 Air fraction of 3 9 0.03 9 0.02 6 -0.12 6 -0.02 Release time of 3 6 0.06 6 0.04 16 -0.02 16 0.00 Air fraction of 4 5 0.07 5 0.05 3 0.41 3 0.09 Release time of 4 1 0.68 1 0.67 1 0.98 1 0.97 Air fraction of 5 11 -0.02 11 -0.01 15 -0.02 15 0.00 Release time of 5 12 0.02 12 0.01 13 -0.03 13 -0.01 Air fraction of 6 16 0.00 16 0.00 8 0.06 8 0.01 Release time of 6 4 -0.09 4 -0.06 10 -0.05 10 -0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:35:40 Page: 41 **

Title : OCS SA_Mn54 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 13 -0.02 11 -0.03 4 0.23 3 0.12 Resuspension Rate 16 0.00 16 0.00 5 -0.20 5 -0.10 Building Exchange Rate 6 -0.06 6 -0.05 2 -0.51 2 -0.13

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 38 of 55 Receptor Ingestion Rate of receptor 1 7 0.05 7 0.04 8 0.09 8 0.02 Air fraction of 1 14 0.02 14 0.01 7 0.11 7 0.03 Release time of 1 3 0.08 3 0.06 11 0.03 11 0.01 Air fraction of 2 15 0.01 15 0.01 15 -0.01 15 0.00 Release time of 2 10 -0.04 10 -0.03 12 -0.03 12 -0.01 Air fraction of 3 12 0.03 13 0.02 16 0.00 16 0.00 Release time of 3 5 0.06 5 0.05 14 -0.01 14 0.00 Air fraction of 4 11 0.03 12 0.02 10 -0.04 10 -0.01 Release time of 4 8 -0.05 8 -0.04 13 -0.01 13 0.00 Air fraction of 5 2 0.21 2 0.16 3 0.42 4 0.10 Release time of 5 1 0.63 1 0.62 1 0.97 1 0.96 Air fraction of 6 9 -0.04 9 -0.03 9 0.05 9 0.01 Release time of 6 4 -0.07 4 -0.05 6 -0.11 6 -0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:35:40 Page: 42 **

Title : OCS SA_Mn54 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 3 0.10 3 0.12 5 0.12 3 0.07 Resuspension Rate 2 -0.15 2 -0.18 13 -0.03 10 -0.02 Building Exchange Rate 11 0.03 11 0.02 2 -0.34 2 -0.09 Receptor Ingestion Rate of receptor 1 9 0.04 9 0.03 7 0.09 7 0.02 Air fraction of 1 8 0.05 8 0.04 4 0.13 5 0.03 Release time of 1 10 0.04 10 0.03 16 0.00 16 0.00 Air fraction of 2 4 0.10 4 0.07 15 0.01 15 0.00 Release time of 2 16 0.00 16 0.00 14 0.02 14 0.00 Air fraction of 3 14 0.01 14 0.01 12 -0.05 13 -0.01 Release time of 3 5 0.09 5 0.07 3 -0.15 4 -0.04 Air fraction of 4 15 0.00 15 0.00 10 0.06 11 0.02 Release time of 4 13 -0.02 13 -0.01 8 -0.09 8 -0.02 Air fraction of 5 12 -0.02 12 -0.01 11 -0.06 12 -0.01 Release time of 5 6 0.07 6 0.05 9 -0.08 9 -0.02 Air fraction of 6 7 -0.06 7 -0.05 6 0.12 6 0.03 Release time of 6 1 0.65 1 0.65 1 0.97 1 0.95 Nb-94 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:50:45 Page: 37 **

Title : OCS SA_Nb94 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 9 -0.03 7 -0.04 7 0.09 5 0.10 Resuspension Rate 12 -0.01 11 -0.02 4 -0.24 4 -0.28 Building Exchange Rate 2 -0.31 2 -0.29 1 -0.76 1 -0.59 Receptor Ingestion Rate of receptor 1 15 0.00 15 0.00 16 0.00 16 0.00 Air fraction of 1 1 0.34 1 0.32 2 0.71 2 0.51 Release time of 1 7 -0.04 8 -0.04 3 0.51 3 0.30 Air fraction of 2 10 0.02 10 0.02 9 -0.06 9 -0.03 Release time of 2 5 0.06 5 0.05 12 -0.04 12 -0.02 Air fraction of 3 11 0.02 12 0.02 13 -0.03 13 -0.01 Release time of 3 14 -0.01 14 -0.01 15 -0.02 15 -0.01 Air fraction of 4 4 -0.06 4 -0.06 10 0.05 10 0.03 Release time of 4 3 -0.08 3 -0.07 11 0.05 11 0.02 Air fraction of 5 8 -0.03 9 -0.03 8 0.09 8 0.05 Release time of 5 16 0.00 16 0.00 14 0.02 14 0.01 Air fraction of 6 6 0.05 6 0.05 6 0.11 7 0.05 Release time of 6 13 0.01 13 0.01 5 0.13 6 0.07

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:50:45 Page: 38 **

Title : OCS SA_Nb94 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(2) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 9 -0.06 4 -0.08 5 0.14 5 0.13 Resuspension Rate 16 -0.01 14 -0.02 4 -0.32 3 -0.31 Building Exchange Rate 2 -0.28 2 -0.26 1 -0.85 1 -0.65 Receptor Ingestion Rate of receptor 1 11 0.05 11 0.05 12 0.05 12 0.02 Air fraction of 1 12 0.04 12 0.04 7 -0.10 7 -0.04 Release time of 1 7 -0.07 8 -0.06 16 0.01 16 0.00 Air fraction of 2 1 0.29 1 0.27 2 0.83 2 0.60 Release time of 2 3 -0.25 3 -0.23 3 -0.33 4 -0.14 Air fraction of 3 5 0.07 6 0.06 8 0.09 8 0.03 Release time of 3 10 -0.06 10 -0.05 11 -0.05 11 -0.02 Air fraction of 4 13 0.04 13 0.03 13 -0.05 13 -0.02 Release time of 4 6 -0.07 7 -0.06 6 -0.13 6 -0.05 Air fraction of 5 14 -0.01 15 -0.01 10 0.06 10 0.02 Release time of 5 15 -0.01 16 -0.01 15 0.03 15 0.01 Air fraction of 6 4 0.09 5 0.08 14 0.03 14 0.01 Release time of 6 8 -0.06 9 -0.06 9 0.08 9 0.03

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 39 of 55

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:50:45 Page: 39 **

Title : OCS SA_Nb94 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 8 0.05 7 0.06 5 0.22 4 0.20 Resuspension Rate 6 -0.08 4 -0.11 4 -0.33 3 -0.32 Building Exchange Rate 2 -0.36 2 -0.33 1 -0.86 1 -0.67 Receptor Ingestion Rate of receptor 1 15 0.01 15 0.01 10 -0.06 10 -0.03 Air fraction of 1 4 0.10 5 0.09 14 -0.02 14 -0.01 Release time of 1 12 -0.02 12 -0.02 12 -0.03 12 -0.01 Air fraction of 2 9 0.04 9 0.03 6 -0.14 6 -0.06 Release time of 2 13 0.02 13 0.02 8 -0.10 8 -0.04 Air fraction of 3 1 0.37 1 0.33 2 0.81 2 0.57 Release time of 3 3 -0.30 3 -0.26 3 -0.41 5 -0.18 Air fraction of 4 14 -0.01 14 -0.01 15 0.02 15 0.01 Release time of 4 16 -0.01 16 -0.01 13 0.02 13 0.01 Air fraction of 5 10 -0.03 10 -0.03 11 0.04 11 0.02 Release time of 5 11 0.03 11 0.02 16 0.00 16 0.00 Air fraction of 6 7 0.05 8 0.04 7 0.10 7 0.04 Release time of 6 5 -0.10 6 -0.08 9 0.07 9 0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:50:45 Page: 40 **

Title : OCS SA_Nb94 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 13 -0.02 11 -0.03 5 0.23 4 0.22 Resuspension Rate 7 -0.05 6 -0.07 3 -0.39 3 -0.39 Building Exchange Rate 3 -0.32 2 -0.28 1 -0.84 1 -0.63 Receptor Ingestion Rate of receptor 1 5 0.14 5 0.12 12 0.03 12 0.01 Air fraction of 1 12 0.03 13 0.02 13 0.02 13 0.01 Release time of 1 15 0.01 15 0.01 9 -0.05 9 -0.02 Air fraction of 2 14 -0.01 14 -0.01 10 0.04 10 0.02 Release time of 2 11 0.03 12 0.02 8 0.05 8 0.02 Air fraction of 3 6 0.06 7 0.05 14 -0.02 14 -0.01 Release time of 3 8 -0.05 8 -0.04 15 0.01 15 0.00 Air fraction of 4 1 0.43 1 0.39 2 0.84 2 0.62 Release time of 4 2 -0.33 3 -0.28 4 -0.33 5 -0.14 Air fraction of 5 10 -0.04 10 -0.03 7 -0.11 7 -0.04 Release time of 5 16 0.00 16 0.00 16 0.00 16 0.00 Air fraction of 6 4 0.20 4 0.17 6 0.21 6 0.09 Release time of 6 9 -0.04 9 -0.03 11 0.03 11 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:50:45 Page: 41 **

Title : OCS SA_Nb94 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 12 0.02 9 0.03 4 0.32 4 0.29 Resuspension Rate 7 -0.05 4 -0.07 3 -0.45 3 -0.43 Building Exchange Rate 2 -0.36 2 -0.33 1 -0.86 1 -0.64 Receptor Ingestion Rate of receptor 1 11 0.02 12 0.02 8 -0.07 8 -0.03 Air fraction of 1 16 0.01 16 0.01 16 -0.01 16 0.00 Release time of 1 4 0.07 5 0.05 11 0.05 11 0.02 Air fraction of 2 15 0.01 15 0.01 14 0.04 14 0.01 Release time of 2 6 -0.06 7 -0.05 7 -0.08 7 -0.03 Air fraction of 3 8 0.04 8 0.03 13 0.05 13 0.02 Release time of 3 9 -0.04 10 -0.03 12 -0.05 12 -0.02 Air fraction of 4 14 0.01 14 0.01 10 0.06 10 0.02 Release time of 4 13 -0.02 13 -0.01 9 -0.07 9 -0.03 Air fraction of 5 1 0.42 1 0.39 2 0.85 2 0.62 Release time of 5 3 -0.24 3 -0.20 5 -0.27 5 -0.10 Air fraction of 6 10 0.02 11 0.02 6 0.15 6 0.06 Release time of 6 5 -0.06 6 -0.05 15 0.02 15 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 18:50:45 Page: 42 **

Title : OCS SA_Nb94 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 16 0.00 16 0.00 5 0.14 4 0.14 Resuspension Rate 14 -0.02 13 -0.03 3 -0.26 3 -0.27 Building Exchange Rate 3 -0.13 3 -0.13 1 -0.84 1 -0.66 Receptor Ingestion Rate of receptor 1 13 -0.02 14 -0.02 7 0.10 7 0.04 Air fraction of 1 12 0.03 12 0.03 11 0.04 11 0.02 Release time of 1 5 0.07 5 0.07 8 0.08 8 0.04 Air fraction of 2 4 0.08 4 0.08 14 -0.01 14 -0.01

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 40 of 55 Release time of 2 11 0.04 11 0.03 16 0.00 16 0.00 Air fraction of 3 8 0.04 8 0.04 13 -0.01 13 -0.01 Release time of 3 10 -0.04 10 -0.04 15 -0.01 15 0.00 Air fraction of 4 6 -0.06 6 -0.06 6 0.12 6 0.05 Release time of 4 7 -0.05 7 -0.05 12 -0.02 12 -0.01 Air fraction of 5 9 -0.04 9 -0.04 10 -0.05 10 -0.02 Release time of 5 15 0.00 15 0.00 9 -0.07 9 -0.03 Air fraction of 6 1 0.17 1 0.17 2 0.81 2 0.59 Release time of 6 2 -0.14 2 -0.13 4 0.19 5 0.08

____________________________________________________ _____ _____ _____ _____ \

Ni-63 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:01:26 Page: 37 **

Title : OCS SA_Ni63 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 16 0.00 14 0.01 10 0.05 6 0.04 Resuspension Rate 12 -0.02 10 -0.02 5 -0.11 4 -0.08 Building Exchange Rate 3 -0.27 3 -0.25 2 -0.88 2 -0.64 Receptor Ingestion Rate of receptor 1 9 0.03 9 0.02 4 0.13 5 0.04 Air fraction of 1 2 0.29 2 0.27 1 0.88 1 0.65 Release time of 1 1 -0.29 1 -0.27 3 -0.58 3 -0.24 Air fraction of 2 11 -0.02 12 -0.02 9 -0.06 10 -0.02 Release time of 2 4 0.09 4 0.08 16 0.01 16 0.00 Air fraction of 3 14 0.00 15 0.00 13 0.03 13 0.01 Release time of 3 15 0.00 16 0.00 7 0.07 8 0.02 Air fraction of 4 7 -0.05 7 -0.04 15 0.02 15 0.01 Release time of 4 5 -0.05 5 -0.05 12 0.03 12 0.01 Air fraction of 5 10 0.02 11 0.02 11 -0.04 11 -0.01 Release time of 5 8 -0.04 8 -0.04 8 0.07 9 0.02 Air fraction of 6 6 0.05 6 0.04 6 0.08 7 0.03 Release time of 6 13 -0.01 13 -0.01 14 0.03 14 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:01:26 Page: 38 **

Title : OCS SA_Ni63 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(2) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 14 -0.03 12 -0.04 7 0.10 5 0.08 Resuspension Rate 16 -0.01 16 -0.02 4 -0.14 4 -0.10 Building Exchange Rate 1 -0.28 1 -0.26 1 -0.90 1 -0.65 Receptor Ingestion Rate of receptor 1 4 0.10 4 0.09 5 0.14 6 0.05 Air fraction of 1 13 0.04 14 0.04 12 -0.07 12 -0.02 Release time of 1 6 -0.08 6 -0.07 14 0.04 14 0.01 Air fraction of 2 3 0.26 3 0.24 2 0.89 2 0.64 Release time of 2 2 -0.28 2 -0.26 3 -0.63 3 -0.26 Air fraction of 3 10 0.06 10 0.05 11 0.08 11 0.02 Release time of 3 9 -0.06 9 -0.05 10 -0.08 10 -0.02 Air fraction of 4 8 0.06 8 0.06 8 -0.08 8 -0.03 Release time of 4 11 -0.05 11 -0.04 6 -0.13 7 -0.04 Air fraction of 5 15 0.03 15 0.02 15 0.04 15 0.01 Release time of 5 12 -0.05 13 -0.04 9 0.08 9 0.02 Air fraction of 6 5 0.09 5 0.08 16 0.02 16 0.01 Release time of 6 7 -0.07 7 -0.06 13 0.07 13 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:01:26 Page: 39 **

Title : OCS SA_Ni63 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.10 4 0.14 5 0.16 5 0.13 Resuspension Rate 5 -0.09 5 -0.13 4 -0.18 4 -0.15 Building Exchange Rate 2 -0.39 2 -0.34 1 -0.89 1 -0.68 Receptor Ingestion Rate of receptor 1 8 0.07 8 0.06 15 0.00 15 0.00 Air fraction of 1 6 0.08 6 0.07 10 -0.06 10 -0.02 Release time of 1 9 -0.04 9 -0.03 12 -0.03 12 -0.01 Air fraction of 2 16 0.01 16 0.01 6 -0.15 6 -0.05 Release time of 2 13 0.02 13 0.02 7 -0.10 7 -0.03 Air fraction of 3 1 0.40 1 0.36 2 0.86 2 0.58 Release time of 3 3 -0.38 3 -0.33 3 -0.61 3 -0.27 Air fraction of 4 10 0.03 10 0.03 13 -0.03 13 -0.01 Release time of 4 14 0.02 14 0.01 14 0.03 14 0.01 Air fraction of 5 15 0.01 15 0.01 16 0.00 16 0.00 Release time of 5 11 0.03 11 0.02 11 -0.05 11 -0.02 Air fraction of 6 12 0.02 12 0.02 9 0.07 9 0.02 Release time of 6 7 -0.07 7 -0.06 8 0.08 8 0.03

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 41 of 55

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:01:26 Page: 40 **

Title : OCS SA_Ni63 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 12 0.02 10 0.03 5 0.16 5 0.13 Resuspension Rate 7 -0.07 6 -0.09 4 -0.24 4 -0.19 Building Exchange Rate 3 -0.32 3 -0.28 2 -0.88 2 -0.63 Receptor Ingestion Rate of receptor 1 4 0.17 4 0.14 7 0.09 7 0.03 Air fraction of 1 16 0.00 16 0.00 12 -0.04 12 -0.01 Release time of 1 14 -0.02 14 -0.02 10 -0.06 10 -0.02 Air fraction of 2 15 -0.02 15 -0.01 15 0.02 15 0.01 Release time of 2 10 0.03 11 0.02 11 0.06 11 0.02 Air fraction of 3 6 0.08 7 0.07 13 -0.04 13 -0.01 Release time of 3 9 -0.04 9 -0.03 16 0.01 16 0.00 Air fraction of 4 1 0.43 1 0.38 1 0.88 1 0.64 Release time of 4 2 -0.34 2 -0.29 3 -0.58 3 -0.25 Air fraction of 5 13 -0.02 13 -0.02 9 -0.08 9 -0.03 Release time of 5 11 -0.03 12 -0.02 14 0.03 14 0.01 Air fraction of 6 5 0.17 5 0.14 6 0.15 6 0.05 Release time of 6 8 -0.07 8 -0.05 8 0.08 8 0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:01:26 Page: 41 **

Title : OCS SA_Ni63 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.07 4 0.09 5 0.20 5 0.15 Resuspension Rate 5 -0.06 5 -0.08 4 -0.22 4 -0.16 Building Exchange Rate 2 -0.35 2 -0.31 1 -0.89 1 -0.65 Receptor Ingestion Rate of receptor 1 9 0.03 9 0.03 8 0.06 8 0.02 Air fraction of 1 13 0.01 13 0.01 15 -0.02 15 -0.01 Release time of 1 8 0.05 8 0.04 9 0.05 9 0.02 Air fraction of 2 15 0.00 15 0.00 7 0.09 7 0.03 Release time of 2 7 -0.06 7 -0.05 13 -0.02 13 -0.01 Air fraction of 3 11 0.03 11 0.03 12 0.03 12 0.01 Release time of 3 6 -0.06 6 -0.05 11 -0.04 11 -0.01 Air fraction of 4 12 0.02 12 0.02 14 0.02 14 0.01 Release time of 4 14 -0.01 14 0.00 16 0.00 16 0.00 Air fraction of 5 1 0.42 1 0.38 2 0.89 2 0.63 Release time of 5 3 -0.30 3 -0.26 3 -0.57 3 -0.23 Air fraction of 6 16 0.00 16 0.00 6 0.14 6 0.05 Release time of 6 10 -0.03 10 -0.03 10 0.04 10 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:01:26 Page: 42 **

Title : OCS SA_Ni63 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 15 -0.01 14 -0.01 10 0.06 7 0.05 Resuspension Rate 14 0.01 13 0.01 6 -0.11 4 -0.09 Building Exchange Rate 3 -0.18 3 -0.17 1 -0.89 1 -0.67 Receptor Ingestion Rate of receptor 1 16 0.00 16 0.00 4 0.16 5 0.05 Air fraction of 1 12 0.02 12 0.02 14 0.03 14 0.01 Release time of 1 5 0.06 5 0.06 9 0.07 10 0.03 Air fraction of 2 4 0.07 4 0.06 16 -0.01 16 0.00 Release time of 2 11 0.03 11 0.02 11 0.05 11 0.02 Air fraction of 3 8 0.05 8 0.04 8 0.08 9 0.03 Release time of 3 7 -0.05 7 -0.04 12 -0.03 12 -0.01 Air fraction of 4 9 -0.04 9 -0.04 5 0.13 6 0.05 Release time of 4 6 -0.05 6 -0.04 13 0.03 13 0.01 Air fraction of 5 10 -0.04 10 -0.04 15 0.02 15 0.01 Release time of 5 13 -0.01 15 -0.01 7 -0.08 8 -0.03 Air fraction of 6 1 0.22 1 0.22 2 0.87 2 0.62 Release time of 6 2 -0.20 2 -0.19 3 -0.56 3 -0.23 Np-237 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 07:21:21 Page: 37 **

Title : OCS SA_Np237 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 15 0.01 14 0.01 13 0.01 13 0.00 Resuspension Rate 13 -0.02 11 -0.02 8 -0.04 5 -0.03

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 42 of 55 Building Exchange Rate 3 -0.25 3 -0.23 1 -0.92 1 -0.61 Receptor Ingestion Rate of receptor 1 14 0.01 15 0.01 6 0.05 7 0.01 Air fraction of 1 2 0.26 2 0.24 2 0.91 2 0.59 Release time of 1 1 -0.33 1 -0.31 3 -0.87 3 -0.47 Air fraction of 2 9 -0.04 9 -0.04 7 -0.04 8 -0.01 Release time of 2 4 0.09 4 0.08 15 0.00 15 0.00 Air fraction of 3 16 0.00 16 0.00 9 0.04 9 0.01 Release time of 3 12 0.02 13 0.01 5 0.08 6 0.02 Air fraction of 4 7 -0.05 7 -0.04 12 0.03 12 0.01 Release time of 4 8 -0.04 8 -0.04 11 -0.03 11 -0.01 Air fraction of 5 10 0.04 10 0.03 10 -0.04 10 -0.01 Release time of 5 6 -0.05 6 -0.04 16 0.00 16 0.00 Air fraction of 6 5 0.05 5 0.04 4 0.11 4 0.03 Release time of 6 11 -0.02 12 -0.02 14 -0.01 14 0.00

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 07:21:21 Page: 38 **

Title : OCS SA_Np237 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(2) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 15 -0.02 15 -0.03 7 0.05 5 0.03 Resuspension Rate 16 -0.01 16 -0.01 16 -0.01 14 -0.01 Building Exchange Rate 2 -0.28 2 -0.25 1 -0.92 1 -0.60 Receptor Ingestion Rate of receptor 1 4 0.09 4 0.08 5 0.10 6 0.03 Air fraction of 1 12 0.05 12 0.04 8 -0.04 8 -0.01 Release time of 1 6 -0.08 6 -0.07 12 0.03 12 0.01 Air fraction of 2 3 0.25 3 0.22 2 0.91 2 0.58 Release time of 2 1 -0.33 1 -0.31 3 -0.89 3 -0.50 Air fraction of 3 10 0.05 10 0.05 14 -0.01 15 0.00 Release time of 3 9 -0.06 9 -0.05 15 -0.01 16 0.00 Air fraction of 4 8 0.07 8 0.06 4 -0.14 4 -0.03 Release time of 4 11 -0.05 11 -0.04 11 -0.03 11 -0.01 Air fraction of 5 14 0.04 14 0.04 13 0.03 13 0.01 Release time of 5 13 -0.05 13 -0.04 10 0.04 10 0.01 Air fraction of 6 5 0.09 5 0.08 9 0.04 9 0.01 Release time of 6 7 -0.07 7 -0.06 6 0.06 7 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 07:21:21 Page: 39 **

Title : OCS SA_Np237 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.11 4 0.15 9 0.05 4 0.03 Resuspension Rate 5 -0.09 5 -0.12 10 -0.05 6 -0.03 Building Exchange Rate 3 -0.38 3 -0.33 1 -0.92 1 -0.62 Receptor Ingestion Rate of receptor 1 9 0.03 9 0.02 5 -0.09 7 -0.02 Air fraction of 1 7 0.06 7 0.05 6 -0.07 8 -0.02 Release time of 1 8 -0.04 8 -0.03 12 -0.04 12 -0.01 Air fraction of 2 14 -0.02 14 -0.01 4 -0.11 5 -0.03 Release time of 2 16 0.00 16 0.00 8 -0.07 10 -0.02 Air fraction of 3 2 0.39 2 0.34 2 0.90 2 0.56 Release time of 3 1 -0.44 1 -0.39 3 -0.87 3 -0.48 Air fraction of 4 10 0.03 10 0.02 14 -0.03 14 -0.01 Release time of 4 11 0.02 11 0.01 15 0.02 15 0.00 Air fraction of 5 12 0.02 12 0.01 16 -0.01 16 0.00 Release time of 5 13 0.02 13 0.01 11 -0.04 11 -0.01 Air fraction of 6 15 0.01 15 0.01 13 -0.04 13 -0.01 Release time of 6 6 -0.06 6 -0.05 7 0.07 9 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 07:21:21 Page: 40 **

Title : OCS SA_Np237 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 10 0.03 9 0.04 15 0.02 10 0.01 Resuspension Rate 7 -0.07 6 -0.10 7 -0.06 4 -0.03 Building Exchange Rate 3 -0.32 3 -0.27 1 -0.91 1 -0.61 Receptor Ingestion Rate of receptor 1 5 0.15 5 0.12 12 -0.03 13 -0.01 Air fraction of 1 16 0.00 16 0.00 9 -0.05 9 -0.01 Release time of 1 12 -0.03 12 -0.02 4 -0.11 5 -0.03 Air fraction of 2 14 -0.02 14 -0.01 11 0.04 12 0.01 Release time of 2 13 0.03 13 0.02 10 0.04 11 0.01 Air fraction of 3 6 0.08 7 0.06 8 -0.05 8 -0.01 Release time of 3 9 -0.05 10 -0.04 14 0.02 15 0.01 Air fraction of 4 1 0.42 1 0.37 2 0.90 2 0.58 Release time of 4 2 -0.39 2 -0.34 3 -0.86 3 -0.47 Air fraction of 5 15 -0.02 15 -0.01 13 -0.02 14 -0.01 Release time of 5 11 -0.03 11 -0.02 16 0.02 16 0.00 Air fraction of 6 4 0.16 4 0.13 6 0.08 7 0.02 Release time of 6 8 -0.06 8 -0.05 5 0.11 6 0.03

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 43 of 55

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 07:21:21 Page: 41 **

Title : OCS SA_Np237 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.08 4 0.11 7 0.06 5 0.03 Resuspension Rate 6 -0.06 5 -0.09 6 -0.06 4 -0.04 Building Exchange Rate 3 -0.34 3 -0.29 1 -0.92 1 -0.61 Receptor Ingestion Rate of receptor 1 13 0.01 13 0.01 10 -0.03 10 -0.01 Air fraction of 1 11 0.02 11 0.01 15 0.01 15 0.00 Release time of 1 7 0.05 7 0.04 14 0.01 14 0.00 Air fraction of 2 16 0.00 16 0.00 5 0.07 7 0.02 Release time of 2 8 -0.05 8 -0.04 16 0.00 16 0.00 Air fraction of 3 9 0.02 9 0.02 12 0.02 12 0.00 Release time of 3 5 -0.07 6 -0.06 9 -0.04 9 -0.01 Air fraction of 4 10 0.02 10 0.02 13 0.02 13 0.00 Release time of 4 14 -0.01 14 0.00 11 -0.02 11 -0.01 Air fraction of 5 1 0.40 1 0.35 2 0.91 2 0.56 Release time of 5 2 -0.38 2 -0.34 3 -0.88 3 -0.47 Air fraction of 6 15 0.00 15 0.00 4 0.13 6 0.03 Release time of 6 12 -0.01 12 -0.01 8 0.04 8 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 07:21:21 Page: 42 **

Title : OCS SA_Np237 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 15 -0.01 13 -0.02 12 0.03 8 0.02 Resuspension Rate 12 0.02 11 0.03 9 -0.04 5 -0.02 Building Exchange Rate 3 -0.19 3 -0.18 1 -0.92 1 -0.63 Receptor Ingestion Rate of receptor 1 16 0.00 16 0.00 16 -0.01 16 0.00 Air fraction of 1 14 0.01 15 0.01 4 0.13 4 0.03 Release time of 1 5 0.06 5 0.05 11 0.03 12 0.01 Air fraction of 2 4 0.06 4 0.06 14 -0.02 14 0.00 Release time of 2 11 0.02 12 0.02 8 0.05 10 0.01 Air fraction of 3 8 0.04 8 0.04 10 -0.03 11 -0.01 Release time of 3 6 -0.05 6 -0.05 7 -0.05 9 -0.01 Air fraction of 4 10 -0.04 10 -0.04 6 0.06 7 0.02 Release time of 4 7 -0.05 7 -0.04 15 0.01 15 0.00 Air fraction of 5 9 -0.04 9 -0.04 13 0.02 13 0.00 Release time of 5 13 -0.02 14 -0.01 5 -0.08 6 -0.02 Air fraction of 6 2 0.23 2 0.23 2 0.91 2 0.57 Release time of 6 1 -0.24 1 -0.23 3 -0.87 3 -0.46 Pu-238 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 19:07:01 Page: 37 **

Title : OCS SA_Pu238 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 14 0.01 12 0.02 13 -0.01 13 -0.01 Resuspension Rate 13 -0.01 11 -0.02 12 -0.01 12 -0.01 Building Exchange Rate 3 -0.25 3 -0.23 1 -0.92 1 -0.61 Receptor Ingestion Rate of receptor 1 15 0.01 15 0.01 9 0.03 9 0.01 Air fraction of 1 2 0.26 2 0.24 2 0.91 2 0.59 Release time of 1 1 -0.33 1 -0.31 3 -0.87 3 -0.47 Air fraction of 2 7 -0.04 7 -0.04 7 -0.04 7 -0.01 Release time of 2 4 0.09 4 0.08 14 0.01 14 0.00 Air fraction of 3 16 0.00 16 0.00 6 0.05 6 0.01 Release time of 3 12 0.02 14 0.02 5 0.08 5 0.02 Air fraction of 4 8 -0.04 8 -0.04 10 0.03 10 0.01 Release time of 4 9 -0.04 9 -0.04 11 -0.02 11 -0.01 Air fraction of 5 10 0.04 10 0.04 8 -0.04 8 -0.01 Release time of 5 5 -0.05 5 -0.04 16 0.00 16 0.00 Air fraction of 6 6 0.05 6 0.04 4 0.12 4 0.03 Release time of 6 11 -0.02 13 -0.02 15 0.00 15 0.00

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 19:07:01 Page: 38 **

Title : OCS SA_Pu238 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(2) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 15 -0.02 15 -0.03 11 0.03 6 0.02 Resuspension Rate 16 -0.01 16 -0.01 12 0.03 8 0.02 Building Exchange Rate 2 -0.27 2 -0.25 1 -0.92 1 -0.60

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 44 of 55 Receptor Ingestion Rate of receptor 1 4 0.09 4 0.08 5 0.08 5 0.02 Air fraction of 1 13 0.05 13 0.04 7 -0.05 9 -0.01 Release time of 1 6 -0.08 6 -0.07 13 0.03 13 0.01 Air fraction of 2 3 0.24 3 0.22 2 0.92 2 0.58 Release time of 2 1 -0.33 1 -0.31 3 -0.89 3 -0.50 Air fraction of 3 10 0.05 10 0.04 15 -0.01 15 0.00 Release time of 3 9 -0.06 9 -0.05 16 -0.01 16 0.00 Air fraction of 4 7 0.07 7 0.06 4 -0.14 4 -0.04 Release time of 4 12 -0.05 12 -0.04 10 -0.03 12 -0.01 Air fraction of 5 14 0.04 14 0.04 14 0.03 14 0.01 Release time of 5 11 -0.05 11 -0.04 9 0.04 11 0.01 Air fraction of 6 5 0.09 5 0.08 8 0.04 10 0.01 Release time of 6 8 -0.07 8 -0.06 6 0.06 7 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 19:07:01 Page: 39 **

Title : OCS SA_Pu238 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.12 4 0.15 12 0.03 8 0.02 Resuspension Rate 5 -0.09 5 -0.12 15 -0.01 15 -0.01 Building Exchange Rate 3 -0.38 3 -0.33 1 -0.92 1 -0.62 Receptor Ingestion Rate of receptor 1 10 0.03 10 0.02 5 -0.10 5 -0.03 Air fraction of 1 7 0.05 7 0.04 6 -0.08 6 -0.02 Release time of 1 8 -0.04 8 -0.03 10 -0.04 11 -0.01 Air fraction of 2 11 -0.02 11 -0.02 4 -0.11 4 -0.03 Release time of 2 16 0.00 16 0.00 8 -0.06 9 -0.02 Air fraction of 3 2 0.39 2 0.34 2 0.90 2 0.56 Release time of 3 1 -0.44 1 -0.39 3 -0.87 3 -0.48 Air fraction of 4 9 0.04 9 0.03 14 -0.02 14 -0.01 Release time of 4 13 0.02 13 0.02 13 0.02 13 0.01 Air fraction of 5 12 0.02 12 0.02 16 -0.01 16 0.00 Release time of 5 14 0.01 14 0.01 9 -0.04 10 -0.01 Air fraction of 6 15 0.01 15 0.00 11 -0.04 12 -0.01 Release time of 6 6 -0.06 6 -0.04 7 0.07 7 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 19:07:01 Page: 40 **

Title : OCS SA_Pu238 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 10 0.03 9 0.05 16 0.00 16 0.00 Resuspension Rate 7 -0.07 6 -0.10 14 -0.02 10 -0.01 Building Exchange Rate 3 -0.31 3 -0.27 1 -0.91 1 -0.61 Receptor Ingestion Rate of receptor 1 5 0.15 5 0.12 9 -0.05 9 -0.01 Air fraction of 1 16 -0.01 16 -0.01 7 -0.06 7 -0.02 Release time of 1 12 -0.03 12 -0.02 4 -0.11 4 -0.03 Air fraction of 2 14 -0.02 14 -0.02 11 0.03 12 0.01 Release time of 2 13 0.02 13 0.02 10 0.04 11 0.01 Air fraction of 3 6 0.08 7 0.06 8 -0.05 8 -0.01 Release time of 3 9 -0.05 10 -0.04 12 0.03 13 0.01 Air fraction of 4 1 0.42 1 0.37 2 0.90 2 0.58 Release time of 4 2 -0.39 2 -0.34 3 -0.87 3 -0.47 Air fraction of 5 15 -0.02 15 -0.01 13 -0.02 14 -0.01 Release time of 5 11 -0.03 11 -0.03 15 0.02 15 0.00 Air fraction of 6 4 0.16 4 0.13 6 0.08 6 0.02 Release time of 6 8 -0.06 8 -0.05 5 0.11 5 0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 19:07:01 Page: 41 **

Title : OCS SA_Pu238 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.08 4 0.11 9 0.03 5 0.02 Resuspension Rate 6 -0.06 5 -0.09 12 -0.02 9 -0.01 Building Exchange Rate 3 -0.34 3 -0.29 1 -0.92 1 -0.61 Receptor Ingestion Rate of receptor 1 13 0.01 13 0.01 6 -0.05 7 -0.01 Air fraction of 1 11 0.02 11 0.01 15 0.00 15 0.00 Release time of 1 7 0.05 7 0.04 13 0.01 13 0.00 Air fraction of 2 15 0.00 15 0.00 5 0.06 6 0.02 Release time of 2 8 -0.05 8 -0.04 16 0.00 16 0.00 Air fraction of 3 10 0.02 10 0.02 11 0.02 12 0.00 Release time of 3 5 -0.07 6 -0.06 8 -0.04 10 -0.01 Air fraction of 4 9 0.02 9 0.02 10 0.02 11 0.00 Release time of 4 14 0.00 14 0.00 14 -0.01 14 0.00 Air fraction of 5 1 0.39 1 0.35 2 0.91 2 0.56 Release time of 5 2 -0.38 2 -0.34 3 -0.88 3 -0.47 Air fraction of 6 16 0.00 16 0.00 4 0.12 4 0.03 Release time of 6 12 -0.01 12 -0.01 7 0.05 8 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 19:07:01 Page: 42 **

Title : OCS SA_Pu238

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 45 of 55 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 14 -0.01 12 -0.02 15 0.01 14 0.00 Resuspension Rate 11 0.03 7 0.05 16 0.00 16 0.00 Building Exchange Rate 3 -0.21 3 -0.20 1 -0.92 1 -0.63 Receptor Ingestion Rate of receptor 1 15 0.01 15 0.01 9 -0.03 9 -0.01 Air fraction of 1 16 0.01 16 0.01 4 0.12 4 0.03 Release time of 1 6 0.05 6 0.05 11 0.03 11 0.01 Air fraction of 2 5 0.05 5 0.05 14 -0.01 15 0.00 Release time of 2 13 0.02 14 0.02 8 0.05 8 0.01 Air fraction of 3 8 0.04 9 0.04 10 -0.03 10 -0.01 Release time of 3 4 -0.06 4 -0.05 7 -0.06 7 -0.02 Air fraction of 4 10 -0.03 11 -0.03 6 0.06 6 0.02 Release time of 4 7 -0.05 8 -0.04 13 0.02 13 0.00 Air fraction of 5 9 -0.04 10 -0.04 12 0.02 12 0.01 Release time of 5 12 -0.02 13 -0.02 5 -0.08 5 -0.02 Air fraction of 6 2 0.25 2 0.24 2 0.91 2 0.57 Release time of 6 1 -0.26 1 -0.24 3 -0.87 3 -0.46 Pu-239 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 14:20:00 Page: 37 **

Title : OCS SA_Pu239 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 15 0.01 14 0.01 13 0.01 13 0.00 Resuspension Rate 13 -0.02 11 -0.02 8 -0.04 5 -0.03 Building Exchange Rate 3 -0.25 3 -0.23 1 -0.92 1 -0.61 Receptor Ingestion Rate of receptor 1 14 0.01 15 0.01 6 0.05 7 0.01 Air fraction of 1 2 0.26 2 0.24 2 0.91 2 0.59 Release time of 1 1 -0.33 1 -0.31 3 -0.87 3 -0.47 Air fraction of 2 9 -0.04 9 -0.04 7 -0.04 8 -0.01 Release time of 2 4 0.09 4 0.08 15 0.00 15 0.00 Air fraction of 3 16 0.00 16 0.00 9 0.04 9 0.01 Release time of 3 12 0.02 13 0.01 5 0.08 6 0.02 Air fraction of 4 7 -0.05 7 -0.04 12 0.03 12 0.01 Release time of 4 8 -0.04 8 -0.04 11 -0.03 11 -0.01 Air fraction of 5 10 0.04 10 0.03 10 -0.04 10 -0.01 Release time of 5 6 -0.05 6 -0.04 16 0.00 16 0.00 Air fraction of 6 5 0.05 5 0.04 4 0.11 4 0.03 Release time of 6 11 -0.02 12 -0.02 14 -0.01 14 0.00

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 14:20:00 Page: 38 **

Title : OCS SA_Pu239 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(2) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 15 -0.02 15 -0.03 7 0.05 5 0.03 Resuspension Rate 16 -0.01 16 -0.01 16 -0.01 14 0.00 Building Exchange Rate 2 -0.28 2 -0.25 1 -0.92 1 -0.60 Receptor Ingestion Rate of receptor 1 4 0.09 4 0.08 5 0.10 6 0.02 Air fraction of 1 12 0.05 12 0.04 8 -0.04 8 -0.01 Release time of 1 6 -0.08 6 -0.07 12 0.03 12 0.01 Air fraction of 2 3 0.25 3 0.22 2 0.91 2 0.58 Release time of 2 1 -0.33 1 -0.31 3 -0.89 3 -0.50 Air fraction of 3 10 0.05 10 0.05 14 -0.01 15 0.00 Release time of 3 9 -0.06 9 -0.05 15 -0.01 16 0.00 Air fraction of 4 8 0.07 8 0.06 4 -0.14 4 -0.04 Release time of 4 11 -0.05 11 -0.04 11 -0.03 11 -0.01 Air fraction of 5 14 0.04 14 0.04 13 0.03 13 0.01 Release time of 5 13 -0.05 13 -0.04 10 0.04 10 0.01 Air fraction of 6 5 0.09 5 0.08 9 0.04 9 0.01 Release time of 6 7 -0.07 7 -0.06 6 0.06 7 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 14:20:00 Page: 39 **

Title : OCS SA_Pu239 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.11 4 0.15 9 0.05 4 0.03 Resuspension Rate 5 -0.09 5 -0.12 10 -0.05 6 -0.03 Building Exchange Rate 3 -0.38 3 -0.33 1 -0.92 1 -0.62 Receptor Ingestion Rate of receptor 1 9 0.03 9 0.02 5 -0.09 7 -0.02 Air fraction of 1 7 0.06 7 0.05 6 -0.07 8 -0.02 Release time of 1 8 -0.04 8 -0.03 12 -0.04 12 -0.01

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 46 of 55 Air fraction of 2 14 -0.02 14 -0.01 4 -0.11 5 -0.03 Release time of 2 16 0.00 16 0.00 8 -0.07 10 -0.02 Air fraction of 3 2 0.39 2 0.34 2 0.90 2 0.56 Release time of 3 1 -0.44 1 -0.39 3 -0.87 3 -0.48 Air fraction of 4 10 0.03 10 0.02 14 -0.03 14 -0.01 Release time of 4 11 0.02 11 0.01 15 0.02 15 0.00 Air fraction of 5 12 0.02 12 0.01 16 -0.01 16 0.00 Release time of 5 13 0.02 13 0.01 11 -0.04 11 -0.01 Air fraction of 6 15 0.01 15 0.01 13 -0.04 13 -0.01 Release time of 6 6 -0.06 6 -0.05 7 0.07 9 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 14:20:00 Page: 40 **

Title : OCS SA_Pu239 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 10 0.03 9 0.04 15 0.02 10 0.01 Resuspension Rate 7 -0.07 6 -0.10 7 -0.06 4 -0.03 Building Exchange Rate 3 -0.32 3 -0.27 1 -0.91 1 -0.61 Receptor Ingestion Rate of receptor 1 5 0.15 5 0.12 12 -0.03 13 -0.01 Air fraction of 1 16 0.00 16 0.00 9 -0.05 9 -0.01 Release time of 1 12 -0.03 12 -0.02 4 -0.11 5 -0.03 Air fraction of 2 14 -0.02 14 -0.01 11 0.04 12 0.01 Release time of 2 13 0.03 13 0.02 10 0.04 11 0.01 Air fraction of 3 6 0.08 7 0.06 8 -0.05 8 -0.01 Release time of 3 9 -0.05 10 -0.04 14 0.02 15 0.01 Air fraction of 4 1 0.42 1 0.37 2 0.90 2 0.58 Release time of 4 2 -0.39 2 -0.34 3 -0.86 3 -0.47 Air fraction of 5 15 -0.02 15 -0.01 13 -0.02 14 -0.01 Release time of 5 11 -0.03 11 -0.02 16 0.02 16 0.00 Air fraction of 6 4 0.16 4 0.13 6 0.08 7 0.02 Release time of 6 8 -0.06 8 -0.05 5 0.11 6 0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 14:20:00 Page: 41 **

Title : OCS SA_Pu239 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.08 4 0.11 7 0.06 5 0.03 Resuspension Rate 6 -0.06 5 -0.09 6 -0.06 4 -0.04 Building Exchange Rate 3 -0.34 3 -0.29 1 -0.92 1 -0.61 Receptor Ingestion Rate of receptor 1 13 0.01 13 0.01 10 -0.03 10 -0.01 Air fraction of 1 11 0.02 11 0.01 15 0.01 15 0.00 Release time of 1 7 0.05 7 0.04 14 0.01 14 0.00 Air fraction of 2 16 0.00 16 0.00 5 0.07 7 0.02 Release time of 2 8 -0.05 8 -0.04 16 0.00 16 0.00 Air fraction of 3 9 0.02 9 0.02 12 0.02 12 0.00 Release time of 3 5 -0.07 6 -0.06 9 -0.04 9 -0.01 Air fraction of 4 10 0.02 10 0.02 13 0.02 13 0.00 Release time of 4 14 -0.01 14 0.00 11 -0.02 11 -0.01 Air fraction of 5 1 0.40 1 0.35 2 0.91 2 0.56 Release time of 5 2 -0.38 2 -0.34 3 -0.88 3 -0.47 Air fraction of 6 15 0.00 15 0.00 4 0.13 6 0.03 Release time of 6 12 -0.01 12 -0.01 8 0.04 8 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 14:20:00 Page: 42 **

Title : OCS SA_Pu239 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 15 -0.01 13 -0.02 12 0.03 8 0.02 Resuspension Rate 12 0.02 11 0.03 9 -0.04 5 -0.02 Building Exchange Rate 3 -0.19 3 -0.18 1 -0.92 1 -0.63 Receptor Ingestion Rate of receptor 1 16 0.00 16 0.00 16 -0.01 16 0.00 Air fraction of 1 14 0.01 15 0.01 4 0.13 4 0.03 Release time of 1 5 0.06 5 0.05 11 0.03 12 0.01 Air fraction of 2 4 0.06 4 0.06 14 -0.02 14 0.00 Release time of 2 11 0.02 12 0.02 8 0.05 10 0.01 Air fraction of 3 8 0.04 8 0.04 10 -0.03 11 -0.01 Release time of 3 6 -0.05 6 -0.05 7 -0.05 9 -0.01 Air fraction of 4 10 -0.04 10 -0.04 6 0.06 7 0.02 Release time of 4 7 -0.05 7 -0.04 15 0.01 15 0.00 Air fraction of 5 9 -0.04 9 -0.04 13 0.02 13 0.00 Release time of 5 13 -0.02 14 -0.01 5 -0.08 6 -0.02 Air fraction of 6 2 0.23 2 0.23 2 0.91 2 0.57 Release time of 6 1 -0.24 1 -0.23 3 -0.87 3 -0.46 Pu-240 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 15:48:59 Page: 37 **

Title : OCS SA_Pu240

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 47 of 55 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 14 0.01 14 0.01 13 0.01 13 0.00 Resuspension Rate 13 -0.02 11 -0.02 9 -0.04 5 -0.02 Building Exchange Rate 3 -0.25 3 -0.23 1 -0.92 1 -0.61 Receptor Ingestion Rate of receptor 1 15 0.01 15 0.01 6 0.05 7 0.01 Air fraction of 1 2 0.26 2 0.24 2 0.91 2 0.59 Release time of 1 1 -0.33 1 -0.31 3 -0.87 3 -0.47 Air fraction of 2 9 -0.04 9 -0.04 7 -0.04 8 -0.01 Release time of 2 4 0.09 4 0.08 15 0.00 15 0.00 Air fraction of 3 16 0.00 16 0.00 8 0.04 9 0.01 Release time of 3 12 0.02 13 0.01 5 0.08 6 0.02 Air fraction of 4 7 -0.05 7 -0.04 12 0.03 12 0.01 Release time of 4 8 -0.04 8 -0.04 11 -0.03 11 -0.01 Air fraction of 5 10 0.04 10 0.03 10 -0.04 10 -0.01 Release time of 5 6 -0.05 6 -0.04 16 0.00 16 0.00 Air fraction of 6 5 0.05 5 0.04 4 0.11 4 0.03 Release time of 6 11 -0.02 12 -0.02 14 -0.01 14 0.00

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 15:48:59 Page: 38 **

Title : OCS SA_Pu240 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(2) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 15 -0.02 15 -0.03 7 0.05 5 0.03 Resuspension Rate 16 -0.01 16 -0.01 16 -0.01 14 0.00 Building Exchange Rate 2 -0.28 2 -0.25 1 -0.92 1 -0.60 Receptor Ingestion Rate of receptor 1 4 0.09 4 0.08 5 0.09 6 0.02 Air fraction of 1 12 0.05 12 0.04 8 -0.04 8 -0.01 Release time of 1 6 -0.08 6 -0.07 12 0.03 12 0.01 Air fraction of 2 3 0.25 3 0.22 2 0.92 2 0.58 Release time of 2 1 -0.33 1 -0.31 3 -0.89 3 -0.50 Air fraction of 3 10 0.05 10 0.05 15 -0.01 16 0.00 Release time of 3 9 -0.06 9 -0.05 14 -0.01 15 0.00 Air fraction of 4 8 0.07 8 0.06 4 -0.14 4 -0.04 Release time of 4 11 -0.05 11 -0.04 11 -0.03 11 -0.01 Air fraction of 5 14 0.04 14 0.04 13 0.03 13 0.01 Release time of 5 13 -0.05 13 -0.04 10 0.04 10 0.01 Air fraction of 6 5 0.09 5 0.08 9 0.04 9 0.01 Release time of 6 7 -0.07 7 -0.06 6 0.06 7 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 15:48:59 Page: 39 **

Title : OCS SA_Pu240 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.11 4 0.15 9 0.05 4 0.03 Resuspension Rate 5 -0.09 5 -0.12 10 -0.05 6 -0.03 Building Exchange Rate 3 -0.38 3 -0.33 1 -0.92 1 -0.62 Receptor Ingestion Rate of receptor 1 10 0.03 9 0.02 5 -0.09 7 -0.02 Air fraction of 1 7 0.06 7 0.05 6 -0.07 8 -0.02 Release time of 1 8 -0.04 8 -0.03 12 -0.04 12 -0.01 Air fraction of 2 13 -0.02 14 -0.01 4 -0.11 5 -0.03 Release time of 2 16 0.00 16 0.00 8 -0.07 10 -0.02 Air fraction of 3 2 0.39 2 0.34 2 0.90 2 0.56 Release time of 3 1 -0.44 1 -0.39 3 -0.87 3 -0.48 Air fraction of 4 9 0.03 10 0.02 14 -0.03 14 -0.01 Release time of 4 11 0.02 11 0.01 15 0.02 15 0.00 Air fraction of 5 12 0.02 12 0.01 16 -0.01 16 0.00 Release time of 5 14 0.02 13 0.01 11 -0.04 11 -0.01 Air fraction of 6 15 0.01 15 0.01 13 -0.04 13 -0.01 Release time of 6 6 -0.06 6 -0.05 7 0.07 9 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 15:48:59 Page: 40 **

Title : OCS SA_Pu240 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 10 0.03 9 0.04 15 0.02 10 0.01 Resuspension Rate 7 -0.07 6 -0.10 7 -0.05 4 -0.03 Building Exchange Rate 3 -0.32 3 -0.27 1 -0.91 1 -0.61 Receptor Ingestion Rate of receptor 1 5 0.15 5 0.12 12 -0.03 13 -0.01 Air fraction of 1 16 0.00 16 0.00 8 -0.05 8 -0.01 Release time of 1 12 -0.03 12 -0.02 4 -0.11 5 -0.03 Air fraction of 2 14 -0.02 14 -0.01 11 0.04 12 0.01 Release time of 2 13 0.02 13 0.02 10 0.04 11 0.01 Air fraction of 3 6 0.08 7 0.06 9 -0.05 9 -0.01

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 48 of 55 Release time of 3 9 -0.05 10 -0.04 14 0.02 15 0.01 Air fraction of 4 1 0.42 1 0.37 2 0.90 2 0.58 Release time of 4 2 -0.39 2 -0.34 3 -0.86 3 -0.47 Air fraction of 5 15 -0.02 15 -0.01 13 -0.02 14 -0.01 Release time of 5 11 -0.03 11 -0.02 16 0.02 16 0.00 Air fraction of 6 4 0.16 4 0.13 6 0.08 7 0.02 Release time of 6 8 -0.06 8 -0.05 5 0.11 6 0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 15:48:59 Page: 41 **

Title : OCS SA_Pu240 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.08 4 0.11 7 0.06 5 0.03 Resuspension Rate 6 -0.06 5 -0.09 6 -0.06 4 -0.04 Building Exchange Rate 3 -0.34 3 -0.29 1 -0.92 1 -0.61 Receptor Ingestion Rate of receptor 1 13 0.01 13 0.01 10 -0.03 10 -0.01 Air fraction of 1 11 0.02 11 0.01 15 0.01 15 0.00 Release time of 1 7 0.05 7 0.04 14 0.01 14 0.00 Air fraction of 2 16 0.00 16 0.00 5 0.07 7 0.02 Release time of 2 8 -0.05 8 -0.04 16 0.00 16 0.00 Air fraction of 3 9 0.02 9 0.02 11 0.02 11 0.01 Release time of 3 5 -0.07 6 -0.06 9 -0.04 9 -0.01 Air fraction of 4 10 0.02 10 0.02 13 0.02 13 0.00 Release time of 4 14 -0.01 14 0.00 12 -0.02 12 -0.01 Air fraction of 5 1 0.40 1 0.35 2 0.91 2 0.56 Release time of 5 2 -0.38 2 -0.34 3 -0.88 3 -0.47 Air fraction of 6 15 0.00 15 0.00 4 0.13 6 0.03 Release time of 6 12 -0.01 12 -0.01 8 0.05 8 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 15:48:59 Page: 42 **

Title : OCS SA_Pu240 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 15 -0.01 13 -0.02 12 0.03 8 0.02 Resuspension Rate 12 0.02 11 0.03 9 -0.04 5 -0.02 Building Exchange Rate 3 -0.19 3 -0.18 1 -0.92 1 -0.63 Receptor Ingestion Rate of receptor 1 16 0.00 16 0.00 16 -0.01 16 0.00 Air fraction of 1 14 0.01 15 0.01 4 0.13 4 0.03 Release time of 1 5 0.06 5 0.05 11 0.03 12 0.01 Air fraction of 2 4 0.06 4 0.06 15 -0.01 15 0.00 Release time of 2 11 0.02 12 0.02 8 0.05 10 0.01 Air fraction of 3 8 0.04 8 0.04 10 -0.03 11 -0.01 Release time of 3 6 -0.05 6 -0.05 7 -0.05 9 -0.01 Air fraction of 4 10 -0.04 10 -0.04 6 0.06 7 0.02 Release time of 4 7 -0.05 7 -0.04 14 0.02 14 0.00 Air fraction of 5 9 -0.04 9 -0.04 13 0.02 13 0.00 Release time of 5 13 -0.02 14 -0.01 5 -0.08 6 -0.02 Air fraction of 6 2 0.24 2 0.23 2 0.91 2 0.57 Release time of 6 1 -0.24 1 -0.23 3 -0.87 3 -0.46 Pu-241 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 22:42:14 Page: 37 **

Title : OCS SA_Pu241 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 14 0.01 14 0.01 11 -0.03 6 -0.02 Resuspension Rate 13 -0.01 11 -0.02 13 0.01 12 0.01 Building Exchange Rate 3 -0.25 3 -0.23 1 -0.92 1 -0.61 Receptor Ingestion Rate of receptor 1 15 0.01 15 0.01 10 0.03 11 0.01 Air fraction of 1 2 0.26 2 0.24 2 0.91 2 0.59 Release time of 1 1 -0.33 1 -0.31 3 -0.87 3 -0.47 Air fraction of 2 5 -0.05 5 -0.04 6 -0.05 7 -0.01 Release time of 2 4 0.09 4 0.08 15 0.01 15 0.00 Air fraction of 3 16 0.00 16 0.00 7 0.04 8 0.01 Release time of 3 11 0.02 12 0.02 5 0.08 5 0.02 Air fraction of 4 9 -0.04 9 -0.04 9 0.03 10 0.01 Release time of 4 10 -0.04 10 -0.03 12 -0.02 13 -0.01 Air fraction of 5 7 0.04 7 0.04 8 -0.04 9 -0.01 Release time of 5 6 -0.05 6 -0.04 14 0.01 14 0.00 Air fraction of 6 8 0.04 8 0.04 4 0.12 4 0.03 Release time of 6 12 -0.02 13 -0.02 16 0.00 16 0.00

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 22:42:14 Page: 38 **

Title : OCS SA_Pu241 Input File : C:\RESRAD_Family\BUILD\3.BLD

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 49 of 55 Coefficients for Source(2) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 15 -0.02 15 -0.03 15 0.01 14 0.00 Resuspension Rate 16 -0.01 16 -0.01 7 0.05 5 0.03 Building Exchange Rate 2 -0.27 2 -0.25 1 -0.92 1 -0.60 Receptor Ingestion Rate of receptor 1 4 0.09 4 0.08 5 0.08 6 0.02 Air fraction of 1 13 0.05 13 0.04 8 -0.05 8 -0.01 Release time of 1 6 -0.08 6 -0.07 13 0.02 13 0.01 Air fraction of 2 3 0.24 3 0.22 2 0.92 2 0.58 Release time of 2 1 -0.34 1 -0.31 3 -0.89 3 -0.50 Air fraction of 3 11 0.05 10 0.04 14 -0.01 15 0.00 Release time of 3 9 -0.06 9 -0.05 16 -0.01 16 0.00 Air fraction of 4 7 0.08 7 0.07 4 -0.14 4 -0.03 Release time of 4 12 -0.05 12 -0.04 11 -0.03 11 -0.01 Air fraction of 5 14 0.05 14 0.04 12 0.03 12 0.01 Release time of 5 10 -0.05 11 -0.04 10 0.04 10 0.01 Air fraction of 6 5 0.08 5 0.07 9 0.04 9 0.01 Release time of 6 8 -0.06 8 -0.06 6 0.07 7 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 22:42:14 Page: 39 **

Title : OCS SA_Pu241 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.12 4 0.16 15 0.01 14 0.01 Resuspension Rate 5 -0.09 5 -0.12 13 0.02 11 0.01 Building Exchange Rate 3 -0.38 3 -0.33 1 -0.92 1 -0.62 Receptor Ingestion Rate of receptor 1 11 0.03 11 0.02 5 -0.10 5 -0.03 Air fraction of 1 8 0.05 8 0.04 6 -0.08 6 -0.02 Release time of 1 6 -0.05 6 -0.04 10 -0.04 10 -0.01 Air fraction of 2 10 -0.03 10 -0.03 4 -0.11 4 -0.03 Release time of 2 15 -0.01 15 -0.01 8 -0.06 8 -0.02 Air fraction of 3 2 0.39 2 0.34 2 0.90 2 0.56 Release time of 3 1 -0.45 1 -0.40 3 -0.87 3 -0.48 Air fraction of 4 9 0.04 9 0.03 14 -0.01 15 0.00 Release time of 4 13 0.02 13 0.02 12 0.03 13 0.01 Air fraction of 5 12 0.03 12 0.02 16 0.00 16 0.00 Release time of 5 14 0.01 14 0.01 9 -0.04 9 -0.01 Air fraction of 6 16 0.00 16 0.00 11 -0.03 12 -0.01 Release time of 6 7 -0.05 7 -0.04 7 0.07 7 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 22:42:14 Page: 40 **

Title : OCS SA_Pu241 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 10 0.03 9 0.04 12 -0.03 7 -0.02 Resuspension Rate 7 -0.07 6 -0.10 16 0.01 14 0.01 Building Exchange Rate 3 -0.31 3 -0.27 1 -0.91 1 -0.61 Receptor Ingestion Rate of receptor 1 5 0.15 5 0.12 9 -0.05 10 -0.01 Air fraction of 1 16 -0.01 16 -0.01 7 -0.06 8 -0.02 Release time of 1 12 -0.03 12 -0.02 5 -0.12 5 -0.03 Air fraction of 2 14 -0.02 14 -0.02 13 0.03 13 0.01 Release time of 2 13 0.02 13 0.02 10 0.04 11 0.01 Air fraction of 3 6 0.08 7 0.06 8 -0.05 9 -0.01 Release time of 3 9 -0.05 10 -0.04 11 0.03 12 0.01 Air fraction of 4 1 0.42 1 0.37 2 0.90 2 0.58 Release time of 4 2 -0.39 2 -0.34 3 -0.86 3 -0.47 Air fraction of 5 15 -0.01 15 -0.01 15 -0.02 16 0.00 Release time of 5 11 -0.03 11 -0.03 14 0.02 15 0.01 Air fraction of 6 4 0.16 4 0.13 6 0.08 6 0.02 Release time of 6 8 -0.06 8 -0.05 4 0.12 4 0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 22:42:14 Page: 41 **

Title : OCS SA_Pu241 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.08 4 0.11 15 0.00 14 0.00 Resuspension Rate 6 -0.06 5 -0.09 12 0.01 9 0.01 Building Exchange Rate 3 -0.33 3 -0.29 1 -0.92 1 -0.61 Receptor Ingestion Rate of receptor 1 13 0.01 13 0.01 7 -0.05 7 -0.01 Air fraction of 1 11 0.02 11 0.01 13 -0.01 13 0.00 Release time of 1 7 0.05 7 0.04 11 0.01 12 0.00 Air fraction of 2 14 0.00 14 0.00 6 0.05 6 0.01 Release time of 2 8 -0.05 8 -0.04 16 0.00 16 0.00 Air fraction of 3 10 0.02 10 0.02 10 0.02 11 0.00 Release time of 3 5 -0.07 6 -0.06 8 -0.04 8 -0.01

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 50 of 55 Air fraction of 4 9 0.03 9 0.02 9 0.03 10 0.01 Release time of 4 15 0.00 15 0.00 14 -0.01 15 0.00 Air fraction of 5 1 0.40 1 0.35 2 0.91 2 0.56 Release time of 5 2 -0.38 2 -0.34 3 -0.88 3 -0.47 Air fraction of 6 16 0.00 16 0.00 4 0.12 4 0.03 Release time of 6 12 -0.01 12 -0.01 5 0.05 5 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/17/22 22:42:14 Page: 42 **

Title : OCS SA_Pu241 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 13 -0.02 10 -0.04 16 -0.01 14 -0.01 Resuspension Rate 5 0.05 4 0.08 14 0.02 10 0.01 Building Exchange Rate 3 -0.24 3 -0.23 1 -0.92 1 -0.63 Receptor Ingestion Rate of receptor 1 12 0.03 13 0.03 9 -0.04 9 -0.01 Air fraction of 1 16 0.00 16 0.00 4 0.12 4 0.03 Release time of 1 9 0.04 9 0.04 10 0.04 11 0.01 Air fraction of 2 8 0.04 8 0.04 15 -0.01 16 0.00 Release time of 2 15 0.01 15 0.01 8 0.05 8 0.01 Air fraction of 3 6 0.04 6 0.04 11 -0.03 12 -0.01 Release time of 3 4 -0.06 5 -0.05 7 -0.06 7 -0.02 Air fraction of 4 14 -0.02 14 -0.01 6 0.06 6 0.02 Release time of 4 7 -0.04 7 -0.04 13 0.02 15 0.00 Air fraction of 5 10 -0.04 11 -0.03 12 0.02 13 0.01 Release time of 5 11 -0.03 12 -0.03 5 -0.07 5 -0.02 Air fraction of 6 2 0.29 2 0.28 2 0.91 2 0.58 Release time of 6 1 -0.30 1 -0.28 3 -0.87 3 -0.46 Sb-125 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:25:34 Page: 37 **

Title : OCS SA_Sb125 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 11 0.02 10 0.03 9 0.04 6 0.02 Resuspension Rate 12 0.01 12 0.01 13 -0.02 10 -0.01 Building Exchange Rate 7 -0.07 7 -0.05 2 -0.49 2 -0.12 Receptor Ingestion Rate of receptor 1 15 0.01 15 0.01 10 -0.04 11 -0.01 Air fraction of 1 5 0.08 5 0.06 3 0.37 3 0.09 Release time of 1 1 0.69 1 0.68 1 0.97 1 0.96 Air fraction of 2 6 0.07 6 0.05 6 0.08 7 0.02 Release time of 2 4 -0.09 4 -0.06 12 -0.03 13 -0.01 Air fraction of 3 16 0.00 16 0.00 4 0.11 4 0.02 Release time of 3 2 -0.10 2 -0.07 8 -0.05 9 -0.01 Air fraction of 4 10 0.04 11 0.03 7 0.07 8 0.02 Release time of 4 14 0.01 14 0.01 14 0.01 14 0.00 Air fraction of 5 13 -0.01 13 -0.01 5 -0.10 5 -0.02 Release time of 5 8 0.06 8 0.05 11 0.03 12 0.01 Air fraction of 6 3 -0.10 3 -0.07 16 -0.01 16 0.00 Release time of 6 9 -0.05 9 -0.04 15 -0.01 15 0.00

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:25:34 Page: 38 **

Title : OCS SA_Sb125 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(2) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 14 0.00 14 0.01 5 0.17 5 0.16 Resuspension Rate 11 -0.03 8 -0.04 4 -0.17 4 -0.17 Building Exchange Rate 3 -0.17 3 -0.14 2 -0.62 2 -0.34 Receptor Ingestion Rate of receptor 1 12 -0.01 12 -0.01 13 -0.02 13 -0.01 Air fraction of 1 8 -0.04 9 -0.03 12 0.02 12 0.01 Release time of 1 6 0.05 6 0.04 7 -0.04 7 -0.02 Air fraction of 2 2 0.22 2 0.19 3 0.54 3 0.28 Release time of 2 1 0.55 1 0.53 1 0.88 1 0.79 Air fraction of 3 5 0.07 5 0.06 8 -0.04 8 -0.02 Release time of 3 16 0.00 16 0.00 16 -0.01 16 0.00 Air fraction of 4 10 0.04 11 0.03 9 -0.03 9 -0.01 Release time of 4 7 -0.05 7 -0.04 10 -0.03 10 -0.01 Air fraction of 5 4 -0.14 4 -0.12 6 -0.08 6 -0.03 Release time of 5 13 0.01 13 0.01 15 0.02 15 0.01 Air fraction of 6 15 0.00 15 0.00 14 0.02 14 0.01 Release time of 6 9 -0.04 10 -0.03 11 0.03 11 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:25:34 Page: 39 **

Title : OCS SA_Sb125 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 51 of 55 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 8 0.07 6 0.09 4 0.15 4 0.14 Resuspension Rate 5 -0.08 5 -0.10 5 -0.12 5 -0.11 Building Exchange Rate 4 -0.14 4 -0.11 2 -0.62 2 -0.32 Receptor Ingestion Rate of receptor 1 10 0.06 10 0.04 10 -0.04 10 -0.01 Air fraction of 1 14 0.02 14 0.01 7 0.10 7 0.04 Release time of 1 13 0.04 13 0.03 15 -0.02 15 -0.01 Air fraction of 2 11 0.05 11 0.04 16 0.01 16 0.00 Release time of 2 15 -0.01 15 -0.01 6 -0.10 6 -0.04 Air fraction of 3 2 0.25 2 0.20 3 0.58 3 0.29 Release time of 3 1 0.59 1 0.57 1 0.89 1 0.80 Air fraction of 4 7 0.07 8 0.05 12 0.03 12 0.01 Release time of 4 12 -0.04 12 -0.03 11 -0.03 11 -0.01 Air fraction of 5 16 0.01 16 0.01 13 -0.03 13 -0.01 Release time of 5 9 0.06 9 0.05 14 -0.03 14 -0.01 Air fraction of 6 3 0.16 3 0.12 8 0.05 8 0.02 Release time of 6 6 -0.07 7 -0.05 9 -0.05 9 -0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:25:34 Page: 40 **

Title : OCS SA_Sb125 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 9 0.04 7 0.06 5 0.13 5 0.13 Resuspension Rate 13 -0.03 10 -0.03 4 -0.13 4 -0.13 Building Exchange Rate 3 -0.14 3 -0.12 2 -0.63 2 -0.36 Receptor Ingestion Rate of receptor 1 4 0.14 4 0.12 6 0.09 6 0.04 Air fraction of 1 12 0.03 13 0.03 12 0.03 12 0.01 Release time of 1 8 0.07 9 0.05 16 0.00 16 0.00 Air fraction of 2 15 0.01 15 0.01 9 0.04 9 0.02 Release time of 2 10 0.04 11 0.03 7 0.07 7 0.03 Air fraction of 3 6 0.08 6 0.06 14 -0.01 14 0.00 Release time of 3 11 0.04 12 0.03 15 -0.01 15 0.00 Air fraction of 4 2 0.25 2 0.21 3 0.50 3 0.25 Release time of 4 1 0.55 1 0.53 1 0.87 1 0.77 Air fraction of 5 14 -0.03 14 -0.02 11 -0.03 11 -0.01 Release time of 5 16 0.00 16 0.00 13 -0.01 13 0.00 Air fraction of 6 7 0.07 8 0.06 10 0.03 10 0.01 Release time of 6 5 -0.12 5 -0.09 8 -0.07 8 -0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:25:34 Page: 41 **

Title : OCS SA_Sb125 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 16 0.00 16 -0.01 4 0.18 4 0.17 Resuspension Rate 14 -0.02 13 -0.02 5 -0.13 5 -0.13 Building Exchange Rate 3 -0.16 3 -0.13 2 -0.67 2 -0.39 Receptor Ingestion Rate of receptor 1 7 0.05 7 0.04 7 0.09 7 0.04 Air fraction of 1 15 0.01 15 0.01 9 0.06 9 0.03 Release time of 1 4 0.09 4 0.07 13 -0.04 13 -0.02 Air fraction of 2 13 0.02 14 0.02 14 0.04 14 0.02 Release time of 2 9 -0.05 9 -0.04 11 -0.05 11 -0.02 Air fraction of 3 12 0.03 12 0.03 15 0.04 15 0.02 Release time of 3 10 0.04 10 0.03 6 -0.12 6 -0.05 Air fraction of 4 11 0.03 11 0.03 10 0.06 10 0.02 Release time of 4 8 -0.05 8 -0.04 8 -0.08 8 -0.03 Air fraction of 5 2 0.31 2 0.27 3 0.59 3 0.32 Release time of 5 1 0.54 1 0.52 1 0.87 1 0.76 Air fraction of 6 6 -0.05 6 -0.04 12 -0.04 12 -0.02 Release time of 6 5 -0.06 5 -0.05 16 0.02 16 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:25:34 Page: 42 **

Title : OCS SA_Sb125 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 7 0.07 4 0.10 4 0.13 4 0.11 Resuspension Rate 4 -0.11 2 -0.16 5 -0.12 5 -0.10 Building Exchange Rate 6 -0.08 6 -0.07 2 -0.50 2 -0.22 Receptor Ingestion Rate of receptor 1 15 0.02 15 0.02 7 0.09 7 0.03 Air fraction of 1 10 0.05 10 0.04 13 0.03 13 0.01 Release time of 1 5 0.08 7 0.07 16 0.00 16 0.00 Air fraction of 2 3 0.12 5 0.10 15 -0.02 15 -0.01 Release time of 2 16 0.01 16 0.01 6 -0.10 6 -0.04 Air fraction of 3 9 0.05 9 0.05 9 0.07 9 0.03 Release time of 3 13 0.04 13 0.04 12 -0.04 12 -0.02 Air fraction of 4 12 -0.04 12 -0.04 14 0.02 14 0.01 Release time of 4 11 -0.04 11 -0.04 11 -0.05 11 -0.02 Air fraction of 5 14 -0.03 14 -0.03 8 0.08 8 0.03

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 52 of 55 Release time of 5 8 0.06 8 0.05 10 0.05 10 0.02 Air fraction of 6 2 0.12 3 0.10 3 0.47 3 0.21 Release time of 6 1 0.44 1 0.43 1 0.91 1 0.87 Sr-90 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:08:45 Page: 37 **

Title : OCS SA_Sr90 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 14 0.01 13 0.01 12 0.04 6 0.03 Resuspension Rate 12 -0.02 11 -0.02 8 -0.07 4 -0.05 Building Exchange Rate 3 -0.27 2 -0.25 1 -0.88 1 -0.65 Receptor Ingestion Rate of receptor 1 11 0.02 12 0.02 4 0.11 5 0.04 Air fraction of 1 1 0.28 1 0.26 2 0.88 2 0.65 Release time of 1 2 -0.27 3 -0.25 3 -0.45 3 -0.18 Air fraction of 2 10 -0.03 10 -0.03 6 -0.08 8 -0.03 Release time of 2 4 0.09 4 0.08 14 0.03 14 0.01 Air fraction of 3 16 0.00 16 0.00 13 0.03 13 0.01 Release time of 3 15 0.01 15 0.00 9 0.05 10 0.02 Air fraction of 4 6 -0.04 6 -0.04 16 0.00 16 0.00 Release time of 4 5 -0.05 5 -0.04 10 0.05 11 0.02 Air fraction of 5 9 0.03 9 0.03 15 -0.02 15 -0.01 Release time of 5 7 -0.04 7 -0.04 7 0.07 9 0.03 Air fraction of 6 8 0.04 8 0.04 5 0.08 7 0.03 Release time of 6 13 -0.01 14 -0.01 11 0.05 12 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:08:45 Page: 38 **

Title : OCS SA_Sr90 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(2) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 14 -0.03 13 -0.04 13 0.07 5 0.06 Resuspension Rate 16 -0.01 16 -0.02 10 -0.09 4 -0.07 Building Exchange Rate 1 -0.28 1 -0.26 1 -0.88 1 -0.66 Receptor Ingestion Rate of receptor 1 4 0.10 4 0.09 7 0.10 9 0.04 Air fraction of 1 13 0.04 14 0.04 8 -0.09 10 -0.03 Release time of 1 6 -0.07 6 -0.06 15 0.01 15 0.00 Air fraction of 2 3 0.26 3 0.24 2 0.87 2 0.63 Release time of 2 2 -0.26 2 -0.24 3 -0.44 3 -0.18 Air fraction of 3 10 0.06 10 0.05 9 0.09 11 0.03 Release time of 3 9 -0.06 9 -0.05 5 -0.10 7 -0.04 Air fraction of 4 7 0.07 7 0.06 11 -0.08 12 -0.03 Release time of 4 11 -0.05 11 -0.04 4 -0.15 6 -0.05 Air fraction of 5 15 0.02 15 0.02 12 0.07 13 0.03 Release time of 5 12 -0.05 12 -0.04 14 0.05 14 0.02 Air fraction of 6 5 0.09 5 0.08 16 0.01 16 0.00 Release time of 6 8 -0.07 8 -0.06 6 0.10 8 0.04

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:08:45 Page: 39 **

Title : OCS SA_Sr90 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.12 4 0.15 4 0.13 4 0.11 Resuspension Rate 5 -0.10 5 -0.13 6 -0.13 5 -0.11 Building Exchange Rate 2 -0.39 2 -0.35 1 -0.89 1 -0.69 Receptor Ingestion Rate of receptor 1 8 0.07 8 0.05 13 -0.03 13 -0.01 Air fraction of 1 7 0.07 7 0.06 9 -0.08 9 -0.03 Release time of 1 10 -0.04 10 -0.03 15 -0.02 15 -0.01 Air fraction of 2 16 0.00 16 0.00 5 -0.13 6 -0.05 Release time of 2 15 0.01 15 0.01 7 -0.10 7 -0.04 Air fraction of 3 1 0.41 1 0.37 2 0.85 2 0.58 Release time of 3 3 -0.36 3 -0.31 3 -0.52 3 -0.22 Air fraction of 4 9 0.04 9 0.04 14 -0.02 14 -0.01 Release time of 4 14 0.02 14 0.01 11 0.06 11 0.02 Air fraction of 5 13 0.02 13 0.01 16 0.01 16 0.00 Release time of 5 11 0.03 11 0.02 12 -0.04 12 -0.01 Air fraction of 6 12 0.03 12 0.02 8 0.08 8 0.03 Release time of 6 6 -0.07 6 -0.06 10 0.08 10 0.03

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:08:45 Page: 40 **

Title : OCS SA_Sr90 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 53 of 55 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 11 0.03 9 0.04 6 0.15 5 0.12 Resuspension Rate 7 -0.07 6 -0.09 4 -0.21 3 -0.18 Building Exchange Rate 2 -0.31 2 -0.27 2 -0.86 2 -0.63 Receptor Ingestion Rate of receptor 1 4 0.17 4 0.14 8 0.09 8 0.03 Air fraction of 1 16 0.00 16 0.00 15 -0.01 15 0.00 Release time of 1 14 -0.02 14 -0.02 10 -0.05 10 -0.02 Air fraction of 2 15 -0.02 15 -0.02 11 0.05 11 0.02 Release time of 2 12 0.03 12 0.02 9 0.08 9 0.03 Air fraction of 3 6 0.08 7 0.07 13 -0.04 13 -0.01 Release time of 3 9 -0.04 10 -0.03 16 0.01 16 0.00 Air fraction of 4 1 0.43 1 0.38 1 0.87 1 0.66 Release time of 4 3 -0.31 3 -0.27 3 -0.43 4 -0.18 Air fraction of 5 13 -0.02 13 -0.02 7 -0.10 7 -0.04 Release time of 5 10 -0.03 11 -0.02 14 0.04 14 0.01 Air fraction of 6 5 0.16 5 0.13 5 0.18 6 0.07 Release time of 6 8 -0.07 8 -0.06 12 0.04 12 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:08:45 Page: 41 **

Title : OCS SA_Sr90 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 4 0.07 4 0.10 4 0.19 4 0.15 Resuspension Rate 5 -0.06 5 -0.09 5 -0.18 5 -0.14 Building Exchange Rate 2 -0.35 2 -0.31 1 -0.88 1 -0.65 Receptor Ingestion Rate of receptor 1 9 0.03 9 0.03 14 0.02 14 0.01 Air fraction of 1 13 0.01 13 0.01 16 -0.01 16 0.00 Release time of 1 7 0.06 7 0.05 9 0.04 9 0.02 Air fraction of 2 16 0.00 16 0.00 7 0.10 7 0.03 Release time of 2 8 -0.05 8 -0.05 12 -0.02 12 -0.01 Air fraction of 3 11 0.03 10 0.02 15 0.01 15 0.00 Release time of 3 6 -0.06 6 -0.05 10 -0.04 10 -0.01 Air fraction of 4 12 0.03 12 0.02 13 0.02 13 0.01 Release time of 4 14 -0.01 14 -0.01 11 -0.03 11 -0.01 Air fraction of 5 1 0.42 1 0.39 2 0.88 2 0.64 Release time of 5 3 -0.27 3 -0.23 3 -0.41 3 -0.16 Air fraction of 6 15 -0.01 15 0.00 6 0.12 6 0.04 Release time of 6 10 -0.03 11 -0.02 8 0.06 8 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:08:45 Page: 42 **

Title : OCS SA_Sr90 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 16 -0.01 14 -0.01 12 0.02 11 0.01 Resuspension Rate 12 0.02 11 0.03 9 -0.05 6 -0.04 Building Exchange Rate 3 -0.20 3 -0.19 1 -0.88 1 -0.67 Receptor Ingestion Rate of receptor 1 15 0.01 15 0.01 4 0.14 4 0.05 Air fraction of 1 14 0.01 16 0.01 15 0.01 15 0.00 Release time of 1 5 0.06 5 0.05 7 0.08 8 0.03 Air fraction of 2 4 0.06 4 0.06 14 -0.01 14 0.00 Release time of 2 11 0.02 12 0.02 10 0.04 10 0.01 Air fraction of 3 8 0.05 8 0.04 8 0.06 9 0.02 Release time of 3 6 -0.05 6 -0.05 13 -0.02 13 -0.01 Air fraction of 4 10 -0.04 10 -0.03 5 0.13 5 0.05 Release time of 4 7 -0.05 7 -0.04 11 0.02 12 0.01 Air fraction of 5 9 -0.04 9 -0.04 16 0.01 16 0.00 Release time of 5 13 -0.01 13 -0.01 6 -0.09 7 -0.03 Air fraction of 6 1 0.25 1 0.24 2 0.86 2 0.62 Release time of 6 2 -0.21 2 -0.20 3 -0.43 3 -0.17 Tc-99 Results:

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:41:36 Page: 37 **

Title : OCS SA_Tc99 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(1) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 9 -0.03 7 -0.05 6 0.12 4 0.11 Resuspension Rate 15 -0.01 14 -0.01 3 -0.28 3 -0.27 Building Exchange Rate 2 -0.27 2 -0.25 1 -0.85 1 -0.64 Receptor Ingestion Rate of receptor 1 4 0.09 4 0.08 5 0.21 6 0.08 Air fraction of 1 1 0.32 1 0.30 2 0.84 2 0.63 Release time of 1 3 -0.26 3 -0.23 4 -0.23 5 -0.09 Air fraction of 2 12 0.02 12 0.02 7 -0.11 7 -0.04 Release time of 2 5 0.09 5 0.08 13 -0.01 13 -0.01 Air fraction of 3 16 0.00 16 0.00 15 0.00 15 0.00 Release time of 3 14 -0.01 15 -0.01 9 0.09 9 0.03 Air fraction of 4 7 -0.04 9 -0.04 14 0.01 14 0.00 Release time of 4 6 -0.06 6 -0.05 10 0.07 10 0.03

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 54 of 55 Air fraction of 5 10 -0.02 10 -0.02 16 0.00 16 0.00 Release time of 5 13 -0.02 13 -0.02 12 0.03 12 0.01 Air fraction of 6 8 0.04 8 0.04 8 0.10 8 0.04 Release time of 6 11 0.02 11 0.02 11 0.04 11 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:41:36 Page: 38 **

Title : OCS SA_Tc99 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(2) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 8 -0.06 5 -0.09 6 0.13 4 0.12 Resuspension Rate 16 0.00 16 -0.01 3 -0.31 3 -0.31 Building Exchange Rate 1 -0.29 1 -0.27 1 -0.84 1 -0.64 Receptor Ingestion Rate of receptor 1 4 0.13 4 0.12 5 0.21 6 0.09 Air fraction of 1 12 0.04 12 0.04 8 -0.09 8 -0.04 Release time of 1 9 -0.06 9 -0.05 16 0.01 16 0.00 Air fraction of 2 2 0.29 2 0.26 2 0.82 2 0.60 Release time of 2 3 -0.25 3 -0.22 4 -0.24 5 -0.10 Air fraction of 3 10 0.05 10 0.05 11 0.07 11 0.03 Release time of 3 11 -0.05 11 -0.04 14 -0.04 14 -0.02 Air fraction of 4 13 0.04 13 0.03 12 -0.06 12 -0.02 Release time of 4 7 -0.07 8 -0.06 7 -0.12 7 -0.05 Air fraction of 5 15 0.01 15 0.01 10 0.08 10 0.03 Release time of 5 14 -0.01 14 -0.01 15 0.03 15 0.01 Air fraction of 6 5 0.09 6 0.08 13 0.05 13 0.02 Release time of 6 6 -0.07 7 -0.06 9 0.09 9 0.04

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:41:36 Page: 39 **

Title : OCS SA_Tc99 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(3) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 12 0.03 10 0.04 5 0.22 4 0.21 Resuspension Rate 9 -0.05 6 -0.08 4 -0.34 3 -0.34 Building Exchange Rate 1 -0.32 1 -0.30 1 -0.85 1 -0.67 Receptor Ingestion Rate of receptor 1 4 0.14 4 0.12 7 0.12 7 0.05 Air fraction of 1 5 0.14 5 0.12 16 0.00 16 0.00 Release time of 1 11 -0.04 12 -0.03 11 -0.03 11 -0.01 Air fraction of 2 7 0.07 8 0.06 6 -0.17 6 -0.07 Release time of 2 8 0.07 9 0.06 8 -0.10 8 -0.04 Air fraction of 3 2 0.32 2 0.29 2 0.80 2 0.56 Release time of 3 3 -0.26 3 -0.23 3 -0.36 5 -0.16 Air fraction of 4 14 0.02 14 0.01 15 0.00 15 0.00 Release time of 4 13 0.03 13 0.02 14 0.01 14 0.00 Air fraction of 5 16 -0.01 16 -0.01 12 0.03 12 0.01 Release time of 5 10 0.04 11 0.04 13 -0.01 13 0.00 Air fraction of 6 15 0.01 15 0.01 9 0.07 9 0.03 Release time of 6 6 -0.08 7 -0.07 10 0.04 10 0.02

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:41:36 Page: 40 **

Title : OCS SA_Tc99 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(4) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 12 -0.03 7 -0.05 5 0.23 4 0.22 Resuspension Rate 10 -0.04 6 -0.05 3 -0.40 3 -0.40 Building Exchange Rate 2 -0.30 2 -0.27 1 -0.84 1 -0.62 Receptor Ingestion Rate of receptor 1 4 0.22 4 0.19 7 0.20 7 0.08 Air fraction of 1 9 0.04 11 0.03 11 0.04 11 0.01 Release time of 1 11 0.04 12 0.03 13 -0.03 13 -0.01 Air fraction of 2 16 -0.01 16 -0.01 10 0.04 10 0.02 Release time of 2 8 0.04 10 0.03 9 0.06 9 0.03 Air fraction of 3 13 0.02 13 0.01 12 -0.03 12 -0.01 Release time of 3 7 -0.04 9 -0.03 15 0.02 15 0.01 Air fraction of 4 1 0.40 1 0.36 2 0.83 2 0.62 Release time of 4 3 -0.28 3 -0.24 4 -0.25 5 -0.11 Air fraction of 5 14 -0.01 14 -0.01 8 -0.09 8 -0.04 Release time of 5 15 0.01 15 0.01 16 0.01 16 0.00 Air fraction of 6 5 0.17 5 0.14 6 0.21 6 0.09 Release time of 6 6 -0.06 8 -0.05 14 0.03 14 0.01

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:41:36 Page: 41 **

Title : OCS SA_Tc99 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(5) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff

BHI Engineering ENG-PNP-002 RESRAD-Build Input Parameter Sensitivity Analysis - OCS Rev. 1 Page 55 of 55 Deposition Velocity 12 0.01 11 0.01 4 0.35 4 0.33 Resuspension Rate 8 -0.04 8 -0.06 3 -0.47 3 -0.47 Building Exchange Rate 2 -0.36 2 -0.32 1 -0.86 1 -0.64 Receptor Ingestion Rate of receptor 1 4 0.12 4 0.10 6 0.15 6 0.06 Air fraction of 1 13 0.01 13 0.01 12 0.05 12 0.02 Release time of 1 6 0.07 6 0.06 16 0.01 16 0.00 Air fraction of 2 14 0.01 14 0.01 9 0.06 9 0.02 Release time of 2 7 -0.07 7 -0.06 8 -0.09 8 -0.04 Air fraction of 3 9 0.03 9 0.03 14 0.03 14 0.01 Release time of 3 15 -0.01 15 0.00 11 -0.05 11 -0.02 Air fraction of 4 11 0.02 12 0.01 10 0.06 10 0.02 Release time of 4 16 0.00 16 0.00 13 -0.03 13 -0.01 Air fraction of 5 1 0.43 1 0.39 2 0.85 2 0.62 Release time of 5 3 -0.21 3 -0.17 5 -0.18 5 -0.07 Air fraction of 6 10 0.02 10 0.02 7 0.11 7 0.04 Release time of 6 5 -0.08 5 -0.06 15 0.01 15 0.00

    • RESRAD-BUILD Regression and Correlation output 3.50 02/16/22 19:41:36 Page: 42 **

Title : OCS SA_Tc99 Input File : C:\RESRAD_Family\BUILD\3.BLD Coefficients for Source(6) at Time: 2 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Deposition Velocity 14 -0.01 14 -0.01 6 0.12 5 0.12 Resuspension Rate 13 -0.01 13 -0.01 3 -0.29 3 -0.28 Building Exchange Rate 3 -0.15 3 -0.14 1 -0.84 1 -0.65 Receptor Ingestion Rate of receptor 1 16 0.00 16 0.00 4 0.28 4 0.12 Air fraction of 1 12 0.03 12 0.03 10 0.04 10 0.02 Release time of 1 5 0.07 5 0.07 9 0.05 9 0.02 Air fraction of 2 4 0.07 4 0.07 15 0.00 15 0.00 Release time of 2 11 0.03 11 0.03 14 0.00 14 0.00 Air fraction of 3 8 0.04 8 0.04 12 0.04 12 0.02 Release time of 3 10 -0.04 10 -0.04 13 0.00 13 0.00 Air fraction of 4 6 -0.05 6 -0.05 7 0.12 7 0.05 Release time of 4 7 -0.05 7 -0.05 11 0.04 11 0.02 Air fraction of 5 9 -0.04 9 -0.04 16 0.00 16 0.00 Release time of 5 15 0.00 15 0.00 8 -0.10 8 -0.04 Air fraction of 6 1 0.19 1 0.19 2 0.82 2 0.60 Release time of 6 2 -0.17 2 -0.16 5 -0.25 6 -0.10

____________________________________________________ _____ _____ _____ _____