ENGINEERING CALCULATION RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Oyster Creek Station ENG-OCS-007 Revision: 0 July 25, 2023 Prepared by:

BHI Energy 97 Libbey Industrial Pkwy Weymouth, MA Prepared by Approved by

BHI Energy ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 1 of 28 1.0 PURPOSE This calculation identifies sensitive input parameters (i.e., those input parameters that produce a significant change in the calculated dose with changes in their value) in the modeling of the Industrial Use scenario using the RESRAD-Onsite code (version 7.2). Identification of sensitive input parameters is a necessary process to account for uncertainty in input values. The uncertainty associated with sensitive input parameters is addressed in subsequent derived concentration guideline levels (DCGL) calculations by determining and assigning reasonably conservative input values based on the results of RESRAD-Onsite probabilistic analyses. Thus, the results of this calculation support the development of DCGL values (based on the Industrial Use scenario) for soil in open land areas at the Oyster Creek Station (OCS) site.

2.0 APPLICABILITY This calculation addresses only the sensitivity analysis for input parameters for the Industrial Use scenario used to develop the DCGL values for soils at the OCS site.

3.0 REFERENCES

3.1 ENG-AP-02, Verification of Software Operability 3.2 ANL/EAD-4, Users Manual for RESRAD Version 6, U.S. Department of Energy -

Argonne National Laboratory, July 2001 3.3 ANL/EVS/TM-18/1, RESRAD-Onsite 7.2 Users Guide, April 2018 3.4 NUREG/CR-7267, Default Parameter Values and Distribution in RESRAD-ONSITE V7.2, RESRAD-BUILD V3.5, and RESRAD-OFFSITE V4.0 Computer Codes, February 2020 3.5 NUREG/CR-5512, Volume 3,

Residual Radioactive Contamination from Decommissioning: Parameter Analysis, Draft Report for Comment, October 1999 3.6 NUREG/CR-6697, Development of Probabilistic RESRAD 6.0 and RESRAD-BUILD 3.0 Computer Codes, Nov. 2000 3.7 Radionuclide Selection for DCGL Development-Oyster Creek Station Site Characterization Project, January 2022 3.8 Oyster Creek Station Historical Site Assessment, Rev. 2, November 2021 3.9 Hydrogeologic Investigation Report, GHD, January 2017 3.10 Health Physics, Vol. 39, Regional and Site-Specific Absolute Humidity Data for Use in Tritium Dose Calculations, 1980 3.11 Yu, C. et al., Data Collection Handbook to Support Modeling the Impacts of Radioactive Material in Soil, Argonne National Laboratory-Environmental Assessment and Information Sciences Division, April 1993 3.12 ANL/EVS/TM-14/4, Data Collection Handbook to Support Modeling the Impacts of Radioactive Material in Soil and Building Structures, Yu, C. et al., Argonne National Laboratory-Environmental Science Division, September 2015 4.0 METHOD OF CALCULATION The operability of the RESRAD-Onsite 7.2 computer code was verified on each computer used for code executions in accordance with BHI Energy Engineering procedure ENG-AP-02, Verification of Software Operability [3.1]. The RESRAD code has undergone extensive review, benchmarking, verification, and validation [3.2]. The RESRAD-Onsite 7.2 Users Guide [3.3] was used as a reference for code use.

BHI Energy ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 2 of 28 The RESidual RADioactivity (RESRAD) model and computer code was developed at Argonne National Laboratory as a multifunctional tool to assist in developing radiological criteria for assessing the dose associated with residual radioactive material. The RESRAD-Onsite computer code is a pathway analysis model designed to evaluate the potential radiological dose associated with residual radioactive material.

RESRAD-Onsite input parameters allow site-specific modeling through entry of site data, such as contaminated zone area and depth, site soil hydrogeologic characteristics, and site soil strata information.

Also, the user can evaluate radiation exposure under different exposure scenarios by selecting scenario-specific exposure pathways.

The RESRAD-Onsite code includes probabilistic modules that permit the user to perform a sensitivity analysis to identify parameters that have the greatest impact on dose. The probabilistic modules allow the evaluation of dose as a function of parameter distributions.

The approach taken in this calculation consists of two primary phases: the selection of input parameter values and performing RESRAD-Onsite code executions.

Input parameters were treated as either deterministic (a single value is assigned) or stochastic (a parameter distribution is assigned). Treatment depended on parameter type, availability of site-specific data, and the relevance of the parameter in the dose calculations. Behavioral and metabolic parameters were treated as deterministic and were assigned values from NUREG/CR-5512 [3.5], NUREG/CR-7267, or the RESRAD User Manual. Physical parameters for which site-specific data are unavailable were assigned parameter distributions from NUREG/CR-7267 or assigned a deterministic value from either NUREG/CR-5512 or the RESRAD Users Manual.

The RESRAD-Onsite Probabilistic Output Report provides regression and correlation coefficients for the average doses at the user defined evaluation times. The Partial Rank Correlation Coefficient (PRCC) has been used to identify sensitive parameters. NUREG/CR-7267 and NUREG/CR-6697 [3.6] recommend the use of the PRCC for cases where a non-linear relationship exists, such as in the case for the Industrial Use Scenario. PRCC values greater than zero (positive value) or less than zero (negative value) identify whether sensitive parameters are positively or negatively correlated to dose, respectively.

The criterion for sensitivity used in this calculation was a PRCC value with an absolute value greater than 0.25. To address the uncertainties associated with the input parameters identified as sensitive, the 25th percentile value of the parameters distribution was selected for sensitive parameters that had a negative PRCC value, and the 75th percentile value of the parameters distribution was selected for sensitive parameters that had a positive PRCC value. The 75th percentile and 25th percentile values are recommended as reasonably conservative input values for calculations of DCGL values for open land areas at the OCS site. The approach of assigning 25th and 75th percentile values of a sensitive parameters distribution to account for uncertainty in DCGL values has been accepted in past decommissioning projects (e.g., Yankee Rowe, Zion, Connecticut Yankee, Humboldt Bay, Fort Calhoun Station, and SMUD) by the U.S. Nuclear Regulatory Commission (NRC) and State regulators.

5.0 INPUT and CALCULATIONS 5.1 Radionuclide-of-concern (ROC) 5.1.1 A site-specific suite of ROCs has been identified for the OCS site [3.7]. OCS ROCs are listed in Table 1.

NOTE: RESRAD-Onsite 7.2 automatically accounts for progeny radionuclides with input for several of the OCS ROCs. Progeny radionuclides are also listed in Table 1).

BHI Energy ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 3 of 28 Table 1: Radionuclides-of-Concern for input to RESRAD-Onsite:

ROCa Progenyb ROCa Progenyb Am-241 Np-237, Th-229, U-233 Nb-94 C-14 Ni-63 Cm-243 Ac-227, Am-243, Pa-231, Pu-239, U-235 Np-237 Th-229, U-233 Cm-244 Pu-240, Ra-228, Th-228, Th-232, U-236 Pu-238 Pb-210, Po-210, Ra-226, Th-230, U-234 Cs-137 Pu-239 Ac-227, Pa-231, U-235 Co-60 Pu-240 Ra-228, Th-228, Th-232, U-236 Eu-152 Gd-152 Pu-241 Am-241, Np-237, Th-229, U-233 Eu-154 Sb-125 Te-125m Fe-55 Sr-90 H-3 Tc-99 Mn-54 a ROC = radionuclide-of-concern identified for the OCS site.

b Included automatically with input of parent ROC.

5.2 Exposure Scenario: The exposure scenario modelled in the sensitivity analyses is an Industrial Use Scenario. The average member of the critical group is a hypothetical full-time industrial site worker assigned outdoor tasks and who also catches and consumes fish from the intake/discharge canal during off-hours. The pathways used to estimate human radiation exposure resulting from residual radioactivity in the soil for this scenario are:

Direct external radiation exposure pathway Inhalation exposure pathway Ingestion exposure via aquatic food from the intake/discharge canal Inadvertent ingestion of contaminated soil 5.3 Time fractions: The industrial worker is assumed to spend 7h per day on outdoor tasks and 1h per day for indoor work breaks (i.e., 15 min morning break, 30 min lunch, and 15 min afternoon break). Under this assumption, the worker spends 35h/week performing outdoor tasks and 5h/week indoors on work breaks. Over a 50-week occupational year (i.e., 50 weeks), the worker spends (35h/week

  • 50weeks =) 1750h outdoors at the industrial site and (5h/week
  • 50weeks =) 250 h indoors at the site. A calendar year has (24h/d
  • 365.25d

=) 8766h.

Fraction of calendar year off-site = (8766h - 2000h)/8766h = 0.77 (no exposure to radioactive material at the site during this time)

Fraction of calendar year outdoors at the site = 1750h/8766h = 0.20 (receives site radiation exposure)

Fraction of calendar year indoors at the site = 250h/8766h = 0.03 (receives site radiation exposure) 5.4 The industrial worker also fishes in the canal during off-hours. The dietary fraction of contaminated aquatic food is evaluated using a distribution from NUREG/CR-7267.

5.5 Contaminated zone (CZ): The OCS yard area within the perimeter fence, 124,400 m2 (based on CAD drawing of OCS PA) is used as input for the area of the CZ.

BHI Energy ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 4 of 28 5.5.1 Plant-related contamination has been reported at depth in OCS documents. Below are a few examples:

Soil samples collected between the MFOT and the RCA fence in late summer 1999 showed detectable radioactivity below the release criteria to a depth of 3 feet (HSA [3.8], section 7.2.1.5.4)

The radionuclides cobalt-60 and cesium-137 were identified down to a depth of almost 13 feet (HSA, section 7.2.1.2.7)

Highest levels of activity were found in the top meter of soil however activity was measured as far down as ~ 4 meters. (OC Contaminated Soil Volumes for Decommissioning Cost Estimates; RE: Old Radwaste Building - Waste Surge Tank Release)

Using 13 feet as the maximum depth for subsurface plant-related contamination, the minimum thickness of the CZ is set to the scenario default value, 6-inches (0.1524m), and the maximum thickness is set to 3.96 meters, which supports a uniform distribution with the minimum value = 0.1524 m, a maximum value = 3.96 m, and a mean value = 2.06 m.

5.5.2 Soil type: Sand was selected as the appropriate soil type for the CZ based on information provided in the 2017 Hydrogeologic Investigation Report [3.9].

5.6 The parameter length parallel to the aquifer flow is defined as is the maximum horizontal distance measured in the CZ, from its up-gradient edge to the down-gradient edge, along the direction of the groundwater flow in the underlying aquifer. The area of the CZ was approximated by a circle with an area of 124,400 m2 (the area of the OCS PA). The diameter of the circle with an area equal to 124,400 m2 was used as input for the length parallel to the aquifer parameter: 398 m.

5.7 Unsaturated zone (UZ):

5.7.1 The depth to ground water at the OCS site ranges from 5 ft to 20 ft [3.9]. Using that information and the minimum thickness of the CZ from step 5.5.1, the maximum thickness of the UZ is set to 19.5 ft (5.94m), which represents the depth from 6 inches to 20 ft (the upper end of the groundwater depth range), and the minimum thickness is set to 4.5 ft (1.37 m), which represents the depth from 6 inches to 5 ft (the lower end of the groundwater depth range). This allows a uniform distribution with a minimum value = 1.37 m, a maximum value = 5.94 m, and a mean = 3.65 m as RESRAD input for thickness of the UZ.

5.7.2 Sand was selected as the appropriate soil type for the UZ based on information provided in the 2017 Hydrogeologic Investigation Report.

5.8 Saturated zone (SZ):

5.8.1 Sand was selected as the appropriate soil type for the SZ based on information provided in the 2017 Hydrogeologic Investigation Report.

5.8.2 Hydraulic gradient in portions of the site range from 0.01 to 0.04 ft/ft [3.9]. This information allows a uniform distribution with a minimum value = 0.01, a maximum value = 0.04, and a mean value = 0.025 as RESRAD-Onsite input.

BHI Energy ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 5 of 28 5.9 The hydraulic conductivity for the site is reported as 24.62 ft/day [3.9]. Conversion to units required for RESRAD-Onsite input yields a hydraulic conductivity value = 2741 m/y.

5.10 The value assigned as input for effective porosity = 0.25 [3.9]

5.11 Input for the watershed area for nearby stream or pond parameter was determined by summing the areas of sub-watersheds within the Forked River/Oyster Creek Watershed (information taken from NJDEP BGIS, NJ GeoWeb site).

Sub-watersheds within the Forked River/Oyster Creek watershed:

Forked River NB (above old RR grade) 5,520.85 acres Forked River NB (below old RR grade) 4,629.91 acres Forked River (below NB incl Mid/South Br) 6,459.25 acres Oyster Creek (above Rt 532) 4,784.77 acres Oyster Creek (below Rt 532) 3,542.30 acres Total area:

24,937.1 acres = 1.01E+08 m2 5.12 The ground surface of the OCS site is described as relatively level [3.9]. Based on that description, an erosion rate equal to 6.0x10-4 m/y was selected for the OCS site as suitable for the Industrial Use scenario. The erosion rate for a relatively level site would not be expected to exceed 6.0x10-4 m/y.

5.13 Input value for annual precipitation was derived from information for the period from 2015 through 2020 (data from Annual Report on the Meteorological Program at Oyster Creek Generating Station for 2015 - 2020).

year Total Precipitation in/y m/y 2015 4.62E+01 1.17E+00 2016 2.79E+01 7.09E-01 2017 4.41E+01 1.12E+00 2018 7.63E+01 1.94E+00 2019 7.27E+01 1.85E+00 2020 6.33E+01 1.61E+00 Average 5.51E+01 1.40E+00 5.14 Figure 1 in Regional and Site-Specific Absolute Humidity Data for Use in Tritium Dose Calculations [3.10] provides mean absolute humidity by geographical regions within the U.S. The figure shows that the OCS site falls inside the area where the mean absolute humidity value is 6.6 g/m3. That value was selected for the RESRAD humidity parameter.

5.15 Field capacity defines the relationship of field capacity (residual water content) to effective porosity. The field capacity is the ratio of the volume of water retained in the soil sample, after all drainage has ceased, to the total volume of the soil sample. Equation 4.4 in NUREG/CR-7267 relates total and effective porosities to field capacity as follows:

Effective Porosity = Total Porosity - Field Capacity Rearranging this equation: Field Capacity = Total Porosity - Effective Porosity For the CZ, UZ, and SZ, the mean total porosity for sand is 0.43 [3.4] and the effective porosity is 0.25 [3.9]. Therefore, the field capacity for these zones is approximately:

BHI Energy ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 6 of 28 Field Capacity = 0.43 - 0.25 = 0.18 5.16 Runoff Coefficient (Cr) was calculated based on information in Table 10.1 of 1993 Data Collection Handbook [3.11], which provides the equation for calculating Cr, and defines and provides values for the equation terms c1, c2, and c3. For the OCS site, Cr = 0.2.

5.17 Inhalation Rate: The distribution from NUREG/CR-7267 was selected as input for daily inhalation rate.

5.18 Soil Ingestion Rate: The distribution from NUREG/CR-7267 was selected as input for soil ingestion.

5.19 Wind speed for OGS is 7 mph (= 3.13 m/s) based on data from 7/2012 - 4/2018 (https://www.windfinder.com/windstatistics/oyster_creek_barnegat_bay) 5.20 Table 2 summarizes the input values/distribution and the reference source for each input parameter.

6.0 RESULTS 6.1 RESRAD-Onsite 7.2 was executed for each ROC using the input values provided in Table

2. An absolute PRCC value 0.25 was used as the criterion for identifying sensitive input parameters.

6.2 Table 3 summarizes the sensitive parameters for each ROC. Selected pages from the RESRAD-Onsite 7.2 Uncertainty Reports from each code execution are provided in Appendix A. RESRAD-Onsite parameters identified as sensitive are highlighted in yellow.

6.3 Table 4 summarizes the 25th and 75th percentile values for each identified sensitive input parameter for each ROC.

Note: For the sensitive parameters, the 75th percentile value of the distribution was selected when the absolute value of the PRCC was 0.25 and the PRCC had a positive value. The 25th percentile value was selected when the absolute value of the PRCC value was 0.25 but had a negative value.

7.0 CONCLUSION

S 7.1 Sensitive input parameters varied among the ROCs and included parameters such as Inhalation rate Mass loading for inhalation Soil ingestion Thickness of CZ Kd in the CZ Kd in the UZ Kd in the SZ External shielding factor Evapotranspiration coefficient Bioaccumulation for fish Contaminated fraction of aquatic food 7.2 The 25th and 75th percentile values for sensitive input parameters (presented in Table 4) provide reasonably conservative input for DCGL development.

BHI Energy ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 7 of 28 Table 2. Summary of Values for RESRAD Input Parameters Values and Bases for RESRAD-Onsite Parameters for Probabilistic Analysis Industrial Use Scenario RESRAD Exposure Pathways External Gamma Open Inhalation Open Plant Ingestion Close Meat Ingestion Close Milk Ingestion Close Aquatic Foods Open Drinking Water Close Soil Ingestion Open Radon Close Parameter (unit)

Typea Priorityb Treatmentc Value/Distribution Basis Distribution's Statistical Parametersd Median/

Mean 1

2 3

4 Soil Concentrations Basic radiation dose limit (mrem/y)

P 3

D 25 10 CFR 20.1402 NR NR NR NR Initial principal radionuclide (pCi/g)

P 2

D 1

Unit Value NR NR NR NR Distribution coefficients (sand soil type assigned to contaminated, unsaturated. and saturated zones) (cm3/g)

Ac-227 P

1 S

Truncated lognormal-n NUREG/CR-7267 7.44 1.1 0.001 0.999 1700 Am-241 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 6.91 1.95 0.001 0.999 1000 Am-243 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 6.91 1.95 0.001 0.999 1000 C-14 P

1 S

Truncated lognormal-n NUREG/CR-7267 3.04 1.82 0.001 0.999 21 Cm-243 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 8.13 2.64 0.001 0.999 3400 Cm-244 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 8.13 2.64 0.001 0.999 3400 Co-60 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 5.56 2.89 0.001 0.999 260 Cs-137 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 6.27 1.79 0.001 0.999 530 Eu-152 P

1 S

Truncated lognormal-n NUREG/CR-7267 6.86 4.01 0.001 0.999 955 Eu-154 P

1 S

Truncated lognormal-n NUREG/CR-7267 6.86 4.01 0.001 0.999 955 Fe-55 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 5.77 0

0.001 0.999 320 Gd-152 P

1 S

Truncated lognormal-n NUREG/CR-7267 1.61 3.22 0.001 0.999 5

H-3 P

1 S

Truncated lognormal-n NUREG/CR-7267

-2.81 0.5 0.001 0.999 0.06 Mn-54 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 6.89 2.64 0.001 0.999 980 Nb-94 P

1 S

Truncated lognormal-n NUREG/CR-7267 7.31 1.39 0.001 0.999 1500 Ni-63 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 4.87 2.3 0.001 0.999 130 Np-237 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 2.64 1.39 0.001 0.999 14 Pa-231 P

1 S

Truncated lognormal-n NUREG/CR-7267 7.6 1.1 0.001 0.999 2000 Pb-210 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 5.39 1.39 0.001 0.999 220 Po-210 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 4.61 1.79 0.001 0.999 100 Pu-238 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 5.99 1.39 0.001 0.999 400 Pu-239 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 5.99 1.39 0.001 0.999 400 Pu-240 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 5.99 1.39 0.001 0.999 400 Pu-241 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 5.99 1.39 0.001 0.999 400 Ra-226 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 8.04 2.08 0.001 0.999 3100 Ra-228 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 8.04 2.08 0.001 0.999 3100 Sb-125 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 2.83 1.79 0.001 0.999 17

BHI Energy ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 8 of 28 Values and Bases for RESRAD-Onsite Parameters for Probabilistic Analysis Industrial Use Scenario Sr-90 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 3.09 1.79 0.001 0.999 22 Tc-99 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4

-3.22 1.1 0.001 0.999 0.04 Te-125m P

1 S

Truncated lognormal-n NUREG/CR-7267 6.31 3.22 0.001 0.999 550 Th-228 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 6.55 2.4 0.001 0.999 700 Th-229 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 6.55 2.4 0.001 0.999 700 Th-230 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 6.55 2.4 0.001 0.999 700 Th-232 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 6.55 2.4 0.001 0.999 700 U-233 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 4.7 2.48 0.001 0.999 110 U-234 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 4.7 2.48 0.001 0.999 110 U-235 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 4.7 2.48 0.001 0.999 110 U-236 P

1 S

Truncated lognormal-n ANL/EVS/TM-14/4 4.7 2.48 0.001 0.999 110 Initial concentration of radionuclides present in groundwater (pCi/l)

P 3

D 0

Ground water uncontaminated NR NR NR NR Calculation Times Time since placement of material (y)

P 3

D 0

NR NR NR NR Time for calculations (y)

P 3

D 1, 3, 10, 30, 100, 300, 1000 RESRAD Default NR NR NR NR Contaminated Zone Area of contaminated zone (m2)

P 2

D 124,400 OCGS PA NR NR NR NR Thickness of contaminated zone (m)

P 2

S Uniform Minimum thickness assumed equal to depth of scenario-defined soil mixing layer (NUREG/CR-5512); maximum thickness based on subsurface soil data in OCGS HSA (section 7.2.1.2.7) 0.1524 3.96 2.06 Length parallel to aquifer flow (m)

P 2

D 398 Site-specific - assumed diameter of a circle with an area = OCGS contaminated zone, 124,400 m2 NR NR NR NR Cover and Contaminated Zone Hydrological Data Cover depth (m)

P 2

D 0

No cover NR NR NR NR Density of contaminated zone (g/cm3)

P 1

S Bounded Normal NUREG/CR-7267 distribution for site soil type - sand.

1.5105 0.159 1.019 2.002 1.5105 Contaminated zone erosion rate (m/y)

P 2

D 6E-04 NUREG/CR-7267; assumed erosion rate for site with shallow slope NR NR NR NR Contaminated zone total porosity P

2 S

Bounded Normal NUREG/CR-7267 distribution for site soil type - sand 0.43 0.06 0.2446 0.6154 0.43 Contaminated zone field capacity P

3 D

0.18 Value based on site-specific soil type (sand);

calculated using equation in NUREG/CR-7267 NR NR NR NR Contaminated zone hydraulic conductivity (m/y)

P 2

D 2741 2017 Hydrogeologic Investigation Report NR NR NR NR Contaminated zone b parameter P

2 S

Bounded Log Normal n NUREG/CR-7267 distribution for site soil type - sand

- 0.0253 0.216 0.501 1.90 0.975

BHI Energy ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 9 of 28 Values and Bases for RESRAD-Onsite Parameters for Probabilistic Analysis Industrial Use Scenario Humidity in air (g/m3)

P 3

D 6.6 Figure 1 in Regional and Site-Specific Absolute Humidity Data for Use in Tritium Dose Calculations NR NR NR NR Evapotranspiration coefficient P

2 S

Uniform NUREG/CR-7267 0.5 0.75 NR NR 0.625 Average annual wind speed (m/s)

P 2

D 3.13 Internet search:

https://www.windfinder.co m/windstatistics/oyster_cre ek_barnegat_bay NR NR NR NR Precipitation (m/y)

P 2

D 1.4 Annual Report on the Meteorological Program at Oyster Creek Generating Station - average annual precipitation for 2015 through 2020 NR NR NR NR Irrigation (m/y)

B 3

D 0.2 RESRAD default NR NR NR NR Irrigation mode B

3 D

Overhead Overhead irrigation is common practice for crops in U.S.

NR NR NR NR Runoff coefficient P

2 D

0.2 Value determined using methodology described in Data Collection Handbook and NUREG/CR-7267 NR NR NR NR Watershed area for nearby stream or pond (m2)

P 3

D 1.01E+08 NJ-GeoWeb (NJDEP BGIS)

NR NR NR NR Accuracy for water/soil computations 3

D 1.00E-03 RESRAD Default NR NR NR NR Saturated Zone Hydrological Data Density of saturated zone (g/cm3)

P 1

S Bounded Normal NUREG/CR-7267 Table C-1, distribution for site soil type - sand 1.5105 0.159 1.019 2.002 1.5105 Saturated zone total porosity P

1 S

Bounded Normal NUREG/CR-7267 distribution for site soil type - sand 0.43 0.06 0.2446 0.6154 0.43 Saturated zone effective porosity P

1 D

0.25 2017 Hydrogeologic Investigation Report NR NR NR NR Saturated zone field capacity P

3 D

0.18 Value based on site-specific soil type (sand);

calculated using equation in NUREG/CR-7267 NR NR NR NR Saturated zone hydraulic conductivity (m/y)

P 1

D 2741 2017 Hydrogeologic Investigation Report NR NR NR NR Saturated zone hydraulic gradient P

2 S

Uniform 2017 Hydrogeologic Investigation Report (section 5.1.4) 0.01 0.04 0.025 Saturated zone b parameter P

2 S

Bounded Log Normal n NUREG/CR-7267 distribution for site soil type - sand

- 0.0253 0.216 0.501 1.90 0.975 Water table drop rate (m/y)

P 3

D 1.00E-03 RESRAD Default NR NR NR NR Well pump intake depth (m below water table)

P 2

D 10 RESRAD Default NR NR NR NR Model:

Nondispersion (ND) or Mass-Balance (MB)

P 3

D ND ND model recommended for contaminant areas

>1,000 m2 NR NR NR NR

BHI Energy ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 10 of 28 Values and Bases for RESRAD-Onsite Parameters for Probabilistic Analysis Industrial Use Scenario Well pumping rate (m3/y)

P 2

N/A Input not required -

drinking water pathway inactive Unsaturated Zone Hydrological Data Number of unsaturated zone strata P

3 D

1 2017 Hydrogeologic Investigation Report (Figures 5.7 & 5.8)

NR NR NR NR Unsat. zone 1, thickness (m)

P 1

S uniform Distribution developed from depth range for site groundwater, 5 ft - 20 ft (2017 Hydrogeologic Investigation Report (section 2.4.3) and mimimum thickness of CZ (0.5 ft) 1.37 5.94 3.65 Unsat. zone 1, soil density (g/cm3)

P 2

S Bounded Normal NUREG/CR-7267 distribution for site soil type - sand 1.5105 0.159 1.019 2.002 1.5105 Unsat. zone 1, total porosity P

2 S

Bounded Normal NUREG/CR-7267 distribution for site soil type - sand 0.43 0.06 0.2446 0.6154 0.43 Unsat. zone 1, effective porosity P

2 D

0.25 2017 Hydrogeologic Investigation Report NR NR NR NR Unsat. zone 1, field capacity P

3 D

0.18 Value based on site-specific soil type (sand);

calculated using equation in NUREG/CR-7267 NR NR NR NR Unsat. zone 1, hydraulic conductivity (m/y)

P 2

D 2741 2017 Hydrogeologic Investigation Report NR NR NR NR Unsat. zone 1, soil-specific b parameter P

2 S

Bounded Log Normal n NUREG/CR-7267 distribution for site soil type - sand

- 0.0253 0.216 0.501 1.90 0.975 Occupancy Inhalation rate (m3/y)

B 3

S Triangular NUREG/CR-7267 4380 8400 13000 8593 Mass loading for inhalation (g/m3)

P 2

S Continuous linear NUREG/CR-7267 2.3E-5 Exposure duration B

3 D

30 RESRAD Default NR NR NR NR Indoor dust filtration factor P

2 S

Uniform NUREG/CR-7267 0.15 0.95 0.55 Shielding factor, external gamma P

2 S

Bounded lognormal-n NUREG/CR-7267

-1.3 0.59 0.044 1

0.2725 Fraction of time spent indoors B

3 D

0.03 Fraction of calendar year assuming 1h/work day for daily work breaks during an occupational year NR NR NR NR Fraction of time spent outdoors B

3 D

0.2 Fraction of calendar year assuming 7h/work day for outside tasks during an occupational year NR NR NR NR Shape factor flag, external gamma P

3 D

Circular RESRAD Default -

Circular contaminated zone assumed NR NR NR NR Ingestion, Dietary Fruits, vegetables, grain consumption (kg/y)

B 2

D N/A Input not required - plant ingestion pathway inactive NR NR NR NR Leafy vegetable consumption (kg/y)

B 3

D N/A Input not required - plant ingestion pathway inactive NR NR NR NR Milk consumption (L/y)

B 2

D N/A Input not required - milk ingestion pathway inactive NR NR NR NR

BHI Energy ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 11 of 28 Values and Bases for RESRAD-Onsite Parameters for Probabilistic Analysis Industrial Use Scenario Meat and poultry consumption (kg/y)

B 3

D N/A Input not required - meat ingestion pathway inactive NR NR NR NR Fish consumption (kg/y)

B 3

D 20.6 NUREG/CR-5512, Vol. 3 NR NR NR NR Other seafood consumption (kg/y)

B 3

D 0.9 RESRAD Default NR NR NR NR Soil & dust ingestion rate (g/yr)

B 2

S Triangular NUREG/CR-7267 0

18.3 36.5 18.3 Drinking water intake (L/y)

B 2

N/A Input not required -

drinking water pathway inactive Contamination fraction of drinking water P

3 N/A Input not required -

drinking water pathway inactive Contamination fraction of household water P

3 N/A Input not required - water pathway inactive Contamination fraction of livestock water P

3 N/A Input not required -

drinking water/ingestion pathways inactive Contamination fraction of irrigation water P

3 N/A Input not required - plant ingestion pathway inactive Contamination fraction of aquatic food P

2 S

Triangular NUREG/CR-7267 0

0.39 1

0.45 Contamination fraction of plant food P

3 N/A Input not required - plant ingestion pathway inactive Contamination fraction of meat P

3 N/A Input not required - meat ingestion pathway inactive Contamination fraction of milk P

3 N/A Input not required - milk ingestion pathway inactive Ingestion, Non-Dietary Livestock fodder intake for meat (kg/d)

M 3

N/A Input not required - meat ingestion pathway inactive Livestock fodder intake for milk (kg/d)

M 3

N/A Input not required - milk ingestion pathway inactive Livestock water intake for meat (L/d)

M 3

N/A Input not required - water ingestion pathway inactive Livestock water intake for milk (L/d)

M 3

N/A Input not required - milk ingestion pathway inactive Livestock soil intake (kg/d)

M 3

N/A Input not required - meat ingestion pathway inactive Mass loading for foliar deposition (g/m3)

P 3

N/A Input not required - plant ingestion pathway inactive Depth of soil mixing layer (m)

P 2

D 0.15 RESRAD Default NR NR NR NR Depth of roots (m)

P 1

N/A Input not required - plant ingestion pathway inactive Drinking water fraction from ground water P

3 N/A Input not required -

drinking water ingestion pathway inactive Household water fraction from ground water (if used)

P 3

N/A Input not required -

drinking water pathway inactive Livestock water fraction from ground water P

3 N/A Input not required -

drinking water/meat ingestion pathways inactive

BHI Energy ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 12 of 28 Values and Bases for RESRAD-Onsite Parameters for Probabilistic Analysis Industrial Use Scenario Irrigation fraction from ground water P

3 N/A Input not required -

drinking water pathway inactive Wet weight crop yield for Non-Leafy (kg/m2)

P 2

N/A Input not required - plant ingestion pathway inactive Wet weight crop yield for Leafy (kg/m2)

P 3

N/A Input not required - plant ingestion pathway inactive Wet weight crop yield for Fodder (kg/m2)

P 3

N/A Input not required - meat ingestion pathway inactive Growing Season for Non-Leafy (y)

P 3

N/A Input not required - plant ingestion pathway inactive Growing Season for Leafy (y)

P 3

N/A Input not required - plant ingestion pathway inactive Growing Season for Fodder (y)

P 3

N/A Input not required - meat ingestion pathway inactive Translocation Factor for Non-Leafy P

3 N/A Input not required - plant ingestion pathway inactive Translocation Factor for Leafy P

3 N/A Input not required - plant ingestion pathway inactive Translocation Factor for Fodder P

3 N/A Input not required - meat ingestion pathway inactive Weathering Removal Constant for Vegetation (1/y)

P 2

N/A Input not required - plant ingestion pathway inactive Wet Foliar Interception Fraction for Non-Leafy P

3 N/A Input not required - plant ingestion pathway inactive Wet Foliar Interception Fraction for Leafy P

2 N/A Input not required - plant ingestion pathway inactive Wet Foliar Interception Fraction for Fodder P

3 N/A Input not required - meat ingestion pathway inactive Dry Foliar Interception Fraction for Non-Leafy P

3 N/A Input not required - plant ingestion pathway inactive Dry Foliar Interception Fraction for Leafy P

3 N/A Input not required - plant ingestion pathway inactive Dry Foliar Interception Fraction for Fodder P

3 N/A Input not required - meat ingestion pathway inactive Storage times of contaminated foodstuffs (days)

Fruits, non-leafy vegetables, and grain B

3 N/A Input not required - plant ingestion pathway inactive Leafy vegetables B

3 N/A Input not required - plant ingestion pathway inactive Milk B

3 N/A Input not required - milk ingestion pathway inactive Meat and poultry B

3 N/A Input not required - meat ingestion pathway inactive Fish B

3 D

7 RESRAD Default NR NR NR NR Crustacea and mollusks B

3 D

7 RESRAD Default NR NR NR NR Well water B

3 N/A Input not required -

drinking water pathway inactive

BHI Energy ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 13 of 28 Values and Bases for RESRAD-Onsite Parameters for Probabilistic Analysis Industrial Use Scenario Surface water B

3 N/A Input not required drinking water pathway inactive Livestock fodder B

3 N/A Input not required - meat ingestion pathway inactive Special Radionuclides (C-14)

C-12 concentration in water (g/cm3)

P 3

D 2.00E-05 RESRAD Default NR NR NR NR C-12 concentration in contaminated soil (g/g)

P 3

D 3.00E-02 RESRAD Default NR NR NR NR Fraction of vegetation carbon from soil P

3 D

2.00E-02 RESRAD Default NR NR NR NR Fraction of vegetation carbon from air P

3 D

9.80E-01 RESRAD Default NR NR NR NR C-14 evasion layer thickness in soil (m)

P 2

D 0.3 RESRAD Default NR NR NR NR C-14 evasion flux rate from soil (1/s)

P 3

D 7.00E-07 RESRAD Default NR NR NR NR C-12 evasion flux rate from soil (1/s)

P 3

D 1.00E-10 RESRAD Default NR NR NR NR Fraction of grain in beef cattle feed B

3 D

0.8 RESRAD Default NR NR NR NR Fraction of grain in milk cow feed B

3 D

0.2 RESRAD Default NR NR NR NR Inhalation Dose Conversion Factors (mrem/pCi inhaled) from FGR11 (contained in RESRAD Dose Conversion Library)

Ingestion Dose Conversion Factors (mrem/pCi ingested) from FGR11 (contained in RESRAD Dose Conversion Library)

Plant Transfer Factors (pCi/g plant)/(pCi/g soil) Note: Plant ingestion pathway closed - input for plant transfer factors not required for Industrial Use dose calculations.

Meat Transfer Factors (pCi/kg)/(pCi/d) Note: Meat ingestion pathway closed - input for meat transfer factors not required for Industrial Use dose calculations.

Milk Transfer Factors (pCi/L)/(pCi/d) Note: Milk ingestion pathway closed - input for milk transfer factors not required for Industrial Use dose calculations.

Bioaccumulation Factors for Fish ((pCi/kg)/(pCi/L))

Ac-227 P

2 S

Lognormal-n NUREG/CR-7267 3.2 1.1 Am-241 P

2 S

Lognormal-n NUREG/CR-7267 5.5 1.1 Am-243 P

2 S

Lognormal-n NUREG/CR-7267 5.5 1.1 C-14 P

2 S

Lognormal-n NUREG/CR-7267 13.0 1.1 Cm-243 P

2 S

Lognormal-n NUREG/CR-7267 3.4 1.1 Cm-244 P

2 S

Lognormal-n NUREG/CR-7267 3.4 1.1 Co-60 P

2 S

Lognormal-n NUREG/CR-7267 4.3 0.9 7.4E+01 Cs-137 P

2 S

Lognormal-n NUREG/CR-7267 7.8 0.9 2.4E+03 Eu-152 P

2 S

Lognormal-n NUREG/CR-7267 4.9 1.6 1.3E+02 Eu-154 P

2 S

Lognormal-n NUREG/CR-7267 4.9 1.6 1.3E+02 Fe-55 P

2 S

Lognormal-n NUREG/CR-7267 5.1 1.9 1.6E+02 Gd-152 P

2 S

Lognormal-n NUREG/CR-7267 3.4 1.1 3.0E+01 H-3 P

2 S

Lognormal-n NUREG/CR-7267 0

0.1 1.0E+00 Mn-54 P

2 S

Lognormal-n NUREG/CR-7267 5.5 1.9 2.4E+02 Nb-94 P

2 S

Lognormal-n NUREG/CR-7267 5.7 1.1 3.0E+02 Ni-63 P

2 S

Lognormal-n NUREG/CR-7267 3.0 0.6 2.0E+01 Np-237 P

2 S

Lognormal-n NUREG/CR-7267 3.0 1.1 2.0E+01 Pa-231 P

2 S

Lognormal-n NUREG/CR-7267 2.3 1.1 1.0E+01

BHI Energy ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 14 of 28 Values and Bases for RESRAD-Onsite Parameters for Probabilistic Analysis Industrial Use Scenario Pb-210 P

2 S

Lognormal-n NUREG/CR-7267 3.2 1.1 2.5E+02 Po-210 P

2 S

Lognormal-n NUREG/CR-7267 3.6 1.5 3.7E+01 Pu-238 P

2 S

Lognormal-n NUREG/CR-7267 10.0 1.0 2.2E+04 Pu-239 P

2 S

Lognormal-n NUREG/CR-7267 10.0 1.0 2.2E+04 Pu-240 P

2 S

Lognormal-n NUREG/CR-7267 10.0 1.0 2.2E+04 Pu-241 P

2 S

Lognormal-n NUREG/CR-7267 10.0 1.0 2.2E+04 Ra-226 P

2 S

Lognormal-n NUREG/CR-7267 1.4 1.9 4.1E+00 Ra-228 P

2 S

Lognormal-n NUREG/CR-7267 1.4 1.9 4.1E+00 Sb-125 P

2 S

Lognormal-n NUREG/CR-7267 3.6 1.5 3.7E+01 Sr-90 P

2 S

Lognormal-n NUREG/CR-7267 1.1 1.4 3.0E+00 Tc-99 P

2 S

Lognormal-n NUREG/CR-7267 3.0 1.1 2.0E+01 Te-125m P

2 S

Lognormal-n NUREG/CR-7267 5.0 0.4 1.5E+02 Th-228 P

2 S

Lognormal-n NUREG/CR-7267 4.6 1.1 9.9E+01 Th-229 P

2 S

Lognormal-n NUREG/CR-7267 4.6 1.1 9.9E+01 Th-230 P

2 S

Lognormal-n NUREG/CR-7267 4.6 1.1 9.9E+01 Th-232 P

2 S

Lognormal-n NUREG/CR-7267 4.6 1.1 9.9E+01 U-233 P

2 S

Lognormal-n NUREG/CR-7267 0.0 2.5 1.0E+00 U-234 P

2 S

Lognormal-n NUREG/CR-7267 0.0 2.5 1.0E+00 U-235 P

2 S

Lognormal-n NUREG/CR-7267 0.0 2.5 1.0E+00 U-236 P

2 S

Lognormal-n NUREG/CR-7267 0.0 2.5 1.0E+00 Bioaccumulation Factors for Crustacea/ Mollusks ((pCi/kg)/(pCi/L)) RESRAD default value for each radionuclide applied Graphics Parameters Number of points 32 RESRAD Default NR NR NR NR Spacing log RESRAD Default NR NR NR NR Time integration parameters Maximum number of points for dose 17 RESRAD Default NR NR NR NR Table 2 Notes:

a P = physical, B = behavioral, M = metabolic b 1 = high-priority parameter, 2 = medium-priority parameter, 3 = low-priority parameter c D = deterministic, S = stochastic N/A = not applicable d Distributions Statistical Parameters:

Lognormal-n: 1= mean, 2 = standard deviation Bounded lognormal-n: 1= mean, 2 = standard deviation, 3 = minimum, 4 = maximum Truncated lognormal-n: 1= mean, 2 = standard deviation, 3 = lower quantile, 4 = upper quantile Bounded normal: 1 = mean, 2 = standard deviation, 3 = minimum, 4 = maximum Triangular: 1 = minimum, 2 = mode, 3 = maximum Uniform: 1 = minimum, 2 = maximum

BHI Engineering ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 15 of 28 Table 3: Sensitive Input Parameter by Radionuclide Radionuclide Sensitive Parameter PRCC Value Am-241 Inhalation Rate Mass Loading for Inhalation Soil Ingestion 0.66 0.84 0.99 C-14 Thickness of CZ Kd in UZ 0.26

-0.51 Cm-243 Inhalation Rate Mass Loading for Inhalation External Shielding Factor Soil Ingestion 0.31 0.49 0.87 0.94 Cm-244 Inhalation Rate Mass Loading for Inhalation Soil Ingestion 0.63 0.82 0.99 Co-60 External Shielding Factor Kd in CZ 0.88 0.48 Cs-137 External Gamma Shielding Factor 0.96 Eu-152 External Shielding Factor Kd in CZ 0.87 0.48 Eu-154 External Shielding Factor Kd in CZ 0.86 0.48 Fe-55 Inhalation Rate Mass Loading for Inhalation Soil Ingestion 0.54 0.77 1.00 H-3 Thickness of CZ Evapotranspiration Coefficient Inhalation Rate Kd in CZ 0.71 0.59 0.80

-0.28 Mn-54 External Shielding Factor Kd in CZ 0.94 0.28 Nb-94 External Shielding Factor 0.96 Ni-63 Soil Ingestion Kd in CZ 1.00 0.36 Np-237 Kd in CZ Mass Loading for Inhalation External Shielding Factor Soil Ingestion 0.61 0.32 0.72 0.85 Pu-238 Inhalation Rate Mass Loading for Inhalation Soil Ingestion 0.62 0.84 0.99 Pu-239 Soil Ingestion Kd in CZ Kd in UZ 0.43 0.57

-0.34 Pu-240 Soil Ingestion Kd in CZ Kd in UZ 0.43 0.54

-0.29

BHI Engineering ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 16 of 28 Radionuclide Sensitive Parameter PRCC Value Pu-241 Kd of Am-241 in CZ Mass Loading for Inhalation Soil Ingestion Kd in CZ 0.44 0.47 0.93 0.28 Sb-125 External Shielding Factor Kd in CZ 0.85 0.73 Sr-90 External Shielding Factor Soil Ingestion Kd in CZ 0.66 0.89 0.59 Tc-99 Contaminated Fraction for Aquatic Food Kd in UZ Fish Transfer Factor 0.53

-0.31 0.80

BHI Engineering ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 17 of 28 Table 4: RESRAD-Generated Percentile Values for Sensitive Input Parameters Sensitive Input Parameter Affected Nuclide RESRAD Percentile Value 25th 75th Inhalation Rate (m3/y)

Am-241 Cm-243 Cm-244 Fe-55 H-3 Pu-238 9.9E+03 9.9E+03 9.9E+03 9.9E+03 9.9E+03 9.9E+03 Mass Loading for Inhalation (g/m3)

Am-241 Cm-243 Cm-244 Fe-55 Np-237 Pu-238 Pu-241 2.9E-05 2.9E-05 2.9E-05 2.9E-05 2.9E-05 2.9E-05 2.9E-05 Soil Ingestion (g/y)

Am-241 Cm-243 Cm-244 Fe-55 Ni-63 Np-237 Pu-238 Pu-239 Pu-240 Pu-241 Sr-90 2.4E+01 2.4E+01 2.4E+01 2.4E+01 2.4E+01 2.4E+01 2.4E+01 2.4E+01 2.4E+01 2.4E+01 2.4E+01 Thickness of CZ (m)

C-14 H-3 3.0E+00 3.0E+00 Kd in CZ (cm3/g)

Am-241 Co-60 Eu-152 Eu-154 H-3 Mn-54 Ni-63 Np-237 Pu-239 Pu-240 Pu-241 Sb-125 Sr-90 3.7E+03 1.8E+03 1.4E+04 1.4E+04 4.3E-02 5.8E+03 6.1E+02 3.6E+01 1.0E+03 1.0E+03 1.0E+03 5.6E+01 7.3E+01 Kd in UZ (cm3/g)

C-14 Pu-239 Pu-240 Tc-99 6.2E+00 1.6E+02 1.6E+02 1.9E-02

BHI Engineering ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 18 of 28 Sensitive Input Parameter Affected Nuclide RESRAD Percentile Value 25th 75th External Shielding Factor Cm-243 Co-60 Cs-137 Eu-152 Eu-154 Mn-54 Nb-94 Np-237 Sb-125 Sr-90 4.0E-01 4.0E-01 4.0E-01 4.0E-01 4.0E-01 4.0E-01 4.0E-01 4.0E-01 4.0E-01 4.0E-01 Evapotranspiration Coefficient H-3 6.9E-01 Bioaccumultion Factor for Fish (pCi/kg)/(pCi/L)

Tc-99 4.2E+01 Contamination Fraction for Aquatic Food Tc-99 6.1E-01

BHI Engineering ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 19 of 28 Appendix A PRCC Values at Time of Peak of the Mean Dose

BHI Engineering ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 20 of 28 Am-241 Results:

1 0.000E+00 2.808E-02 RESRAD Regression and Correlation output 07/11/23 10:28 Page: Coef 1 Title : OCNGS Industrial Use_Probabilistic Analysis_Am241 Input File : OC_IU_SA_AM241.RAD Coefficients for peak of mean dose time Dose Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Kd of Am-241 in Contaminated Zone 6 0.06 9 0.00 6 0.09 6 0.01 Kd of Am-241 in Unsaturated Zone 1 32 0.00 32 0.00 18 0.02 22 0.00 Kd of Am-241 in Saturated Zone 31 0.00 31 0.00 25 -0.01 29 0.00 Kd of Np-237 in Contaminated Zone 13 -0.03 17 0.00 8 -0.04 11 0.00 Kd of Np-237 in Unsaturated Zone 1 21 0.01 23 0.00 9 0.04 12 0.00 Kd of Np-237 in Saturated Zone 22 0.01 24 0.00 13 -0.03 16 0.00 Kd of Th-229 in Contaminated Zone 28 0.00 28 0.00 20 -0.02 23 0.00 Kd of Th-229 in Unsaturated Zone 1 30 0.00 30 0.00 30 0.00 30 0.00 Kd of Th-229 in Saturated Zone 16 0.02 20 0.00 10 -0.04 13 0.00 Kd of U-233 in Contaminated Zone 8 0.05 12 0.00 32 0.00 32 0.00 Kd of U-233 in Unsaturated Zone 1 23 -0.01 25 0.00 31 0.00 31 0.00 Kd of U-233 in Saturated Zone 24 0.01 26 0.00 16 0.03 19 0.00 Fish transfer factor for Am 20 -0.01 22 0.00 7 -0.04 10 -0.01 Fish transfer factor for Np 7 -0.05 10 0.00 17 0.03 20 0.00 Fish transfer factor for Th 19 0.01 21 0.00 34 0.00 35 0.00 Fish transfer factor for U 34 0.00 34 0.00 33 0.00 34 0.00 Thickness of contaminated zone 9 0.04 6 0.01 22 -0.02 9 -0.01 Density of contaminated zone 26 0.01 19 0.00 29 0.00 28 0.00 Contaminated zone total porosity 35 0.00 35 0.00 27 -0.01 25 0.00 Contaminated zone b parameter 15 0.03 18 0.00 12 0.04 15 0.00 Evapotranspiration coefficient 29 0.00 29 0.00 24 -0.01 27 0.00 Density of saturated zone 14 0.03 8 0.01 35 0.00 33 0.00 Saturated zone total porosity 11 0.03 7 0.01 26 0.01 21 0.00 Saturated zone hydraulic gradient 10 -0.04 14 0.00 15 -0.03 18 0.00 Saturated zone b parameter 12 0.03 16 0.00 14 0.03 17 0.00 Thickness of Unsaturated zone 1 17 0.02 13 0.00 19 -0.02 7 -0.01 Density of Unsaturated zone 1 25 -0.01 15 0.00 21 -0.02 8 -0.01 Total Porosity of Unsaturated zone 1 18 -0.02 11 0.00 28 0.00 26 0.00 b Parameter of Unsaturated zone 1 33 0.00 33 0.00 23 0.02 24 0.00 Inhalation rate 3 0.91 3 0.12 3 0.66 3 0.11 Mass loading for inhalation 2 0.97 2 0.23 2 0.84 2 0.19 Indoor dust filtration factor 5 0.32 5 0.02 5 0.12 5 0.02 External gamma shielding factor 4 0.57 4 0.04 4 0.21 4 0.03 Soil ingestion 1 1.00 1 0.96 1 0.99 1 0.97 Aquatic food 27 0.00 27 0.00 11 -0.04 14 0.00 C-14 Results:

RESRAD Regression and Correlation output 07/12/23 09:20 Page: Coef 1 Title : OCNGS Industrial Use_Probabilistic Analysis_C14 Input File : OC_IU_SA_C-14.RAD Coefficients for peak of mean dose time Dose Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Thickness of contaminated zone 19 0.01 11 0.03 2 0.26 1 0.54 Density of contaminated zone 20 0.01 12 0.03 22 0.00 22 0.00 Contaminated zone total porosity 17 0.01 8 0.04 20 0.01 15 0.02 Contaminated zone b parameter 5 -0.03 10 -0.03 23 0.00 23 0.00 Evapotranspiration coefficient 7 -0.03 13 -0.03 5 -0.05 8 -0.03 Density of saturated zone 8 -0.02 3 -0.07 13 0.03 5 0.05 Saturated zone total porosity 10 -0.02 5 -0.07 17 0.02 6 0.04 Saturated zone hydraulic gradient 21 -0.01 22 -0.01 12 -0.03 14 -0.02 Saturated zone b parameter 3 0.04 7 0.04 8 0.04 11 0.03 Thickness of Unsaturated zone 1 23 -0.01 18 -0.02 4 -0.05 3 -0.11 Density of Unsaturated zone 1 9 0.02 4 0.07 21 0.01 16 0.02 Total Porosity of Unsaturated zone 1 6 0.03 2 0.08 11 0.03 4 0.06 b Parameter of Unsaturated zone 1 18 -0.01 21 -0.01 16 -0.02 19 -0.01 Inhalation rate 16 -0.01 20 -0.01 14 0.02 17 0.02 Mass loading for inhalation 14 0.02 17 0.02 18 0.02 20 0.01 Indoor dust filtration factor 22 -0.01 23 -0.01 6 0.05 9 0.03 External gamma shielding factor 4 0.04 9 0.04 15 0.02 18 0.01 Soil ingestion 15 -0.02 19 -0.02 7 -0.04 10 -0.03 Aquatic food 2 0.05 6 0.05 10 0.03 13 0.02 Kd of C-14 in Contaminated Zone 11 -0.02 14 -0.02 9 0.04 12 0.02 Kd of C-14 in Unsaturated Zone 1 12 -0.02 15 -0.02 1 -0.51 2 -0.39 Kd of C-14 in Saturated Zone 13 -0.02 16 -0.02 3 -0.05 7 -0.04 Fish transfer factor for C 1 0.11 1 0.11 19 0.02 21 0.01 Cm-243 Results:

RESRAD Regression and Correlation output 07/12/23 09:45 Page: Coef 1 Title : OCNGS Industrial Use_Probabilistic Analysis_Cm243 Input File : OC_IU_SA_CM243.RAD Coefficients for peak of mean dose time Dose Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Thickness of contaminated zone 7 0.04 6 0.02 10 0.03 5 0.03 Density of contaminated zone 6 0.04 5 0.03 33 0.01 15 0.01 Contaminated zone total porosity 9 0.03 7 0.02 37 0.00 25 0.00 Contaminated zone b parameter 14 0.03 17 0.01 17 -0.02 21 0.00

BHI Engineering ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 21 of 28 Evapotranspiration coefficient 42 0.00 42 0.00 29 -0.01 34 0.00 Density of saturated zone 18 -0.02 9 -0.01 18 -0.02 8 -0.01 Saturated zone total porosity 28 -0.01 12 -0.01 41 0.00 32 0.00 Saturated zone hydraulic gradient 12 0.03 15 0.01 15 0.02 19 0.01 Saturated zone b parameter 19 -0.02 21 0.00 11 0.03 12 0.01 Thickness of Unsaturated zone 1 27 -0.01 10 -0.01 31 0.01 13 0.01 Density of Unsaturated zone 1 41 0.00 36 0.00 43 0.00 39 0.00 Total Porosity of Unsaturated zone 1 40 0.00 35 0.00 34 -0.01 17 -0.01 b Parameter of Unsaturated zone 1 35 0.01 38 0.00 8 0.03 10 0.01 Inhalation rate 4 0.42 4 0.09 4 0.31 4 0.09 Mass loading for inhalation 3 0.68 3 0.19 3 0.49 3 0.16 Indoor dust filtration factor 5 0.09 8 0.02 5 0.08 6 0.02 External gamma shielding factor 2 0.94 2 0.55 2 0.87 2 0.50 Soil ingestion 1 0.97 1 0.78 1 0.94 1 0.79 Aquatic food 10 -0.03 13 -0.01 19 0.02 22 0.00 Kd of Ac-227 in Contaminated Zone 20 0.02 22 0.00 28 0.01 33 0.00 Kd of Ac-227 in Unsaturated Zone 1 11 -0.03 14 -0.01 35 -0.01 37 0.00 Kd of Ac-227 in Saturated Zone 16 -0.02 19 0.00 25 -0.01 29 0.00 Kd of Am-243 in Contaminated Zone 22 0.02 24 0.00 7 -0.04 9 -0.01 Kd of Am-243 in Unsaturated Zone 1 21 0.02 23 0.00 40 0.00 42 0.00 Kd of Am-243 in Saturated Zone 30 0.01 30 0.00 21 -0.01 24 0.00 Kd of Cm-243 in Contaminated Zone 13 0.03 16 0.01 6 0.07 7 0.02 Kd of Cm-243 in Unsaturated Zone 1 25 0.01 27 0.00 39 0.00 41 0.00 Kd of Cm-243 in Saturated Zone 33 0.01 33 0.00 16 -0.02 20 -0.01 Kd of Pa-231 in Contaminated Zone 43 0.00 43 0.00 14 0.02 18 0.01 Kd of Pa-231 in Unsaturated Zone 1 29 0.01 29 0.00 9 0.03 11 0.01 Kd of Pa-231 in Saturated Zone 37 0.00 40 0.00 26 0.01 30 0.00 Kd of Pu-239 in Contaminated Zone 23 0.01 25 0.00 13 0.02 16 0.01 Kd of Pu-239 in Unsaturated Zone 1 15 0.02 18 0.00 38 0.00 40 0.00 Kd of Pu-239 in Saturated Zone 38 0.00 39 0.00 22 -0.01 26 0.00 Kd of U-235 in Contaminated Zone 36 0.01 37 0.00 42 0.00 43 0.00 Kd of U-235 in Unsaturated Zone 1 26 -0.01 28 0.00 36 0.01 38 0.00 Kd of U-235 in Saturated Zone 39 0.00 41 0.00 12 0.02 14 0.01 Fish transfer factor for Ac 34 0.01 34 0.00 30 -0.01 35 0.00 Fish transfer factor for Am 17 0.02 20 0.00 27 -0.01 31 0.00 Fish transfer factor for Cm 31 0.01 31 0.00 24 -0.01 28 0.00 Fish transfer factor for Pu 24 0.01 26 0.00 23 -0.01 27 0.00 Fish transfer factor for U 32 0.01 32 0.00 20 0.01 23 0.00 Fish transfer factor for Pa 8 -0.04 11 -0.01 32 0.01 36 0.00 Cm-244 Results:

RESRAD Regression and Correlation output 07/12/23 10:02 Page: Coef 1 Title : OCNGS Industrial Use_Probabilistic Analysis_Cm244 Input File : OC_IU_SA_CM244.RAD Coefficients for peak of mean dose time Dose Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Thickness of contaminated zone 32 -0.01 21 0.00 30 0.01 14 0.00 Density of contaminated zone 9 -0.03 5 -0.01 24 -0.01 11 0.00 Contaminated zone total porosity 10 -0.03 6 -0.01 12 -0.02 7 -0.01 Contaminated zone b parameter 38 0.00 38 0.00 27 -0.01 29 0.00 Evapotranspiration coefficient 5 0.06 8 0.00 16 0.02 19 0.00 Density of saturated zone 28 -0.01 16 0.00 36 0.00 35 0.00 Saturated zone total porosity 29 -0.01 17 0.00 29 -0.01 13 0.00 Saturated zone hydraulic gradient 24 -0.01 27 0.00 17 -0.02 20 0.00 Saturated zone b parameter 6 0.05 10 0.00 20 0.01 23 0.00 Thickness of Unsaturated zone 1 12 -0.03 7 -0.01 37 0.00 36 0.00 Density of Unsaturated zone 1 17 0.02 9 0.00 6 0.05 4 0.02 Total Porosity of Unsaturated zone 1 20 0.01 12 0.00 7 0.05 5 0.02 b Parameter of Unsaturated zone 1 23 -0.01 26 0.00 25 -0.01 27 0.00 Inhalation rate 3 0.89 3 0.12 3 0.63 3 0.11 Mass loading for inhalation 2 0.97 2 0.24 2 0.82 2 0.20 Indoor dust filtration factor 4 0.30 4 0.02 4 0.12 6 0.02 External gamma shielding factor 30 0.01 31 0.00 23 0.01 26 0.00 Soil ingestion 1 1.00 1 0.96 1 0.99 1 0.96 Aquatic food 11 0.03 14 0.00 15 -0.02 18 0.00 Kd of Cm-244 in Contaminated Zone 13 0.03 15 0.00 5 0.06 8 0.01 Kd of Cm-244 in Unsaturated Zone 1 33 -0.01 34 0.00 18 0.02 21 0.00 Kd of Cm-244 in Saturated Zone 42 0.00 42 0.00 8 -0.04 9 -0.01 Kd of Pu-240 in Contaminated Zone 39 0.00 39 0.00 41 0.00 41 0.00 Kd of Pu-240 in Unsaturated Zone 1 37 0.00 37 0.00 42 0.00 42 0.00 Kd of Pu-240 in Saturated Zone 18 -0.01 22 0.00 38 0.00 38 0.00 Kd of Ra-228 in Contaminated Zone 21 0.01 24 0.00 35 0.00 37 0.00 Kd of Ra-228 in Unsaturated Zone 1 16 -0.02 20 0.00 10 -0.03 12 0.00 Kd of Ra-228 in Saturated Zone 22 0.01 25 0.00 32 0.01 32 0.00 Kd of Th-228 in Contaminated Zone 31 0.01 32 0.00 31 0.01 31 0.00 Kd of Th-228 in Unsaturated Zone 1 40 0.00 40 0.00 22 0.01 25 0.00 Kd of Th-228 in Saturated Zone 35 0.00 35 0.00 14 -0.02 17 0.00 Kd of Th-232 in Contaminated Zone 15 0.02 19 0.00 19 0.01 22 0.00 Kd of Th-232 in Unsaturated Zone 1 34 -0.01 33 0.00 34 0.01 34 0.00 Kd of Th-232 in Saturated Zone 25 -0.01 28 0.00 28 -0.01 30 0.00 Kd of U-236 in Contaminated Zone 27 -0.01 30 0.00 40 0.00 40 0.00 Kd of U-236 in Unsaturated Zone 1 36 0.00 36 0.00 13 0.02 16 0.00 Kd of U-236 in Saturated Zone 19 -0.01 23 0.00 26 -0.01 28 0.00 Fish transfer factor for Cm 7 -0.04 11 0.00 9 -0.04 10 -0.01 Fish transfer factor for Pu 8 -0.03 13 0.00 21 -0.01 24 0.00 Fish transfer factor for Ra 26 0.01 29 0.00 11 0.02 15 0.00 Fish transfer factor for Th 14 0.02 18 0.00 39 0.00 39 0.00 Fish transfer factor for U 41 0.00 41 0.00 33 0.01 33 0.00 Co-60 Results:

RESRAD Regression and Correlation output 07/12/23 10:11 Page: Coef 1 Title : Co60 Input File : OC_IU_SA_CO60.RAD Coefficients for peak of mean dose time Dose

BHI Engineering ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 22 of 28 Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Thickness of contaminated zone 2 0.07 2 0.17 3 0.08 3 0.11 Density of contaminated zone 12 0.01 6 0.04 4 0.04 4 0.06 Contaminated zone total porosity 21 0.00 19 -0.01 12 0.02 7 0.03 Contaminated zone b parameter 9 -0.02 12 -0.01 16 -0.02 16 -0.01 Evapotranspiration coefficient 7 0.02 11 0.02 13 0.02 14 0.01 Density of saturated zone 16 0.01 9 0.03 21 0.00 19 0.00 Saturated zone total porosity 22 0.00 22 0.00 23 0.00 22 0.00 Saturated zone hydraulic gradient 13 0.01 14 0.01 9 -0.03 12 -0.01 Saturated zone b parameter 14 -0.01 15 -0.01 11 -0.02 13 -0.01 Thickness of Unsaturated zone 1 10 -0.02 5 -0.04 6 -0.04 5 -0.06 Density of Unsaturated zone 1 5 0.03 3 0.08 10 0.03 6 0.04 Total Porosity of Unsaturated zone 1 8 0.02 4 0.05 14 0.02 8 0.03 b Parameter of Unsaturated zone 1 17 0.01 17 0.01 8 0.03 11 0.01 Inhalation rate 15 0.01 16 0.01 20 0.01 21 0.00 Mass loading for inhalation 11 -0.02 13 -0.01 22 0.00 23 0.00 Indoor dust filtration factor 3 -0.04 7 -0.04 19 -0.01 20 0.00 External gamma shielding factor 1 0.52 1 0.51 1 0.88 1 0.84 Soil ingestion 18 0.01 18 0.01 7 0.03 10 0.02 Aquatic food 23 0.00 23 0.00 17 -0.01 17 0.00 Kd of Co-60 in Contaminated Zone 4 0.04 8 0.03 2 0.48 2 0.25 Kd of Co-60 in Unsaturated Zone 1 20 -0.01 21 -0.01 15 0.02 15 0.01 Kd of Co-60 in Saturated Zone 6 0.03 10 0.02 5 0.04 9 0.02 Fish transfer factor for Co 19 -0.01 20 -0.01 18 0.01 18 0.00 Cs-137 Results:

RESRAD Regression and Correlation output 07/12/23 10:19 Page: Coef 1 Title : OCNGS Industrial Use_Probabilistic Analysis_Cs137 Input File : OC_IU_SA_CS137.RAD Coefficients for peak of mean dose time Dose Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Thickness of contaminated zone 2 0.07 2 0.08 3 0.08 2 0.07 Density of contaminated zone 20 0.01 14 0.01 14 0.02 8 0.02 Contaminated zone total porosity 12 -0.02 8 -0.03 18 -0.01 12 -0.01 Contaminated zone b parameter 18 0.01 19 0.00 15 0.02 17 0.00 Evapotranspiration coefficient 15 0.02 16 0.01 9 0.03 13 0.01 Density of saturated zone 11 0.02 7 0.03 8 0.03 6 0.03 Saturated zone total porosity 10 0.03 6 0.03 7 0.03 5 0.03 Saturated zone hydraulic gradient 7 0.03 11 0.01 4 0.04 10 0.01 Saturated zone b parameter 21 0.00 21 0.00 19 -0.01 19 0.00 Thickness of Unsaturated zone 1 4 -0.04 4 -0.04 5 -0.04 4 -0.03 Density of Unsaturated zone 1 3 -0.04 3 -0.05 13 -0.02 7 -0.02 Total Porosity of Unsaturated zone 1 8 -0.03 5 -0.04 17 -0.02 9 -0.01 b Parameter of Unsaturated zone 1 6 0.04 10 0.01 6 0.04 11 0.01 Inhalation rate 9 0.03 12 0.01 10 0.03 14 0.01 Mass loading for inhalation 16 0.02 17 0.01 21 0.00 21 0.00 Indoor dust filtration factor 14 0.02 15 0.01 11 0.03 15 0.01 External gamma shielding factor 1 0.93 1 0.93 1 0.96 1 0.95 Soil ingestion 19 -0.01 20 0.00 20 0.01 20 0.00 Aquatic food 13 0.02 13 0.01 16 0.02 18 0.00 Kd of Cs-137 in Contaminated Zone 5 0.04 9 0.01 2 0.18 3 0.05 Kd of Cs-137 in Unsaturated Zone 1 22 0.00 22 0.00 12 0.03 16 0.01 Kd of Cs-137 in Saturated Zone 17 0.02 18 0.01 22 0.00 22 0.00 Eu-152 Results:

RESRAD Regression and Correlation output 07/12/23 10:26 Page: Coef 1 Title : OCNGS Industrial Use_Probabilistic Analysis_Eu152 Input File : OC_IU_SA_EU152.RAD Coefficients for peak of mean dose time Dose Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Thickness of contaminated zone 3 0.06 2 0.17 3 0.10 3 0.15 Density of contaminated zone 5 0.03 3 0.09 14 0.02 7 0.03 Contaminated zone total porosity 13 0.02 7 0.04 25 0.00 24 0.00 Contaminated zone b parameter 9 0.02 12 0.02 20 -0.02 21 -0.01 Evapotranspiration coefficient 2 0.06 4 0.06 4 0.08 6 0.04 Density of saturated zone 25 0.00 20 -0.01 22 0.01 10 0.02 Saturated zone total porosity 26 0.00 24 0.01 19 0.02 8 0.03 Saturated zone hydraulic gradient 19 0.01 21 0.01 18 0.02 20 0.01 Saturated zone b parameter 17 0.01 17 0.01 26 0.00 27 0.00 Thickness of Unsaturated zone 1 24 0.00 19 -0.01 27 0.00 26 0.00 Density of Unsaturated zone 1 11 0.02 6 0.05 11 0.03 5 0.04 Total Porosity of Unsaturated zone 1 15 0.01 8 0.03 6 0.03 4 0.05 b Parameter of Unsaturated zone 1 12 0.02 14 0.01 5 0.05 9 0.02 Inhalation rate 23 0.00 26 0.00 9 0.03 13 0.01 Mass loading for inhalation 27 0.00 27 0.00 13 -0.02 16 -0.01 Indoor dust filtration factor 18 -0.01 18 -0.01 21 0.01 22 0.01 External gamma shielding factor 1 0.37 1 0.36 1 0.87 1 0.83 Soil ingestion 20 0.01 22 0.01 10 0.03 14 0.01 Aquatic food 22 -0.01 25 -0.01 7 0.03 11 0.02 Kd of Eu-152 in Contaminated Zone 7 0.02 10 0.02 2 0.48 2 0.26 Kd of Eu-152 in Unsaturated Zone 1 14 0.01 15 0.01 23 -0.01 23 0.00 Kd of Eu-152 in Saturated Zone 10 -0.02 13 -0.02 17 0.02 19 0.01 Kd of Gd-152 in Contaminated Zone 4 -0.06 5 -0.05 12 -0.02 15 -0.01 Kd of Gd-152 in Unsaturated Zone 1 21 0.01 23 0.01 24 0.00 25 0.00 Kd of Gd-152 in Saturated Zone 16 -0.01 16 -0.01 15 -0.02 17 -0.01 Fish transfer factor for Eu 6 -0.03 9 -0.02 16 0.02 18 0.01 Fish transfer factor for Gd 8 -0.02 11 -0.02 8 -0.03 12 -0.02

BHI Engineering ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 23 of 28 Eu-154 Results:

RESRAD Regression and Correlation output 07/12/23 10:32 Page: Coef 1 Title : OCNGS Industrial Use_Probabilistic Analysis_Eu152 Input File : OC_IU_SA_EU154.RAD Coefficients for peak of mean dose time Dose Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Thickness of contaminated zone 2 0.04 2 0.12 3 0.06 3 0.08 Density of contaminated zone 18 0.01 9 0.02 5 0.04 4 0.05 Contaminated zone total porosity 19 -0.01 12 -0.02 12 0.02 7 0.03 Contaminated zone b parameter 8 -0.01 13 -0.01 13 -0.02 14 -0.01 Evapotranspiration coefficient 10 0.01 14 0.01 14 0.02 15 0.01 Density of saturated zone 14 0.01 6 0.03 22 0.00 19 0.00 Saturated zone total porosity 23 0.00 22 0.00 23 0.00 23 0.00 Saturated zone hydraulic gradient 20 0.01 20 0.00 9 -0.03 12 -0.01 Saturated zone b parameter 17 -0.01 19 -0.01 10 -0.03 13 -0.01 Thickness of Unsaturated zone 1 9 -0.01 5 -0.04 6 -0.03 5 -0.05 Density of Unsaturated zone 1 4 0.02 3 0.07 11 0.02 6 0.03 Total Porosity of Unsaturated zone 1 11 0.01 4 0.04 15 0.02 9 0.02 b Parameter of Unsaturated zone 1 16 0.01 18 0.01 8 0.03 11 0.02 Inhalation rate 13 0.01 16 0.01 17 0.01 17 0.01 Mass loading for inhalation 12 -0.01 15 -0.01 21 -0.01 22 0.00 Indoor dust filtration factor 3 -0.03 7 -0.03 18 -0.01 18 -0.01 External gamma shielding factor 1 0.39 1 0.39 1 0.86 1 0.82 Soil ingestion 15 0.01 17 0.01 7 0.03 10 0.02 Aquatic food 22 0.00 23 0.00 20 -0.01 21 0.00 Kd of Eu-154 in Contaminated Zone 5 0.02 8 0.02 2 0.48 2 0.26 Kd of Eu-154 in Unsaturated Zone 1 21 0.01 21 0.00 16 0.01 16 0.01 Kd of Eu-154 in Saturated Zone 6 0.02 10 0.02 4 0.05 8 0.02 Fish transfer factor for Eu 7 -0.02 11 -0.02 19 0.01 20 0.00 Fe-55 Results:

RESRAD Regression and Correlation output 07/12/23 10:39 Page: Coef 1 Title : OCNGS Industrial Use_Probabilistic Analysis_Fe55 Input File : OC_IU_SA_FE55.RAD Coefficients for peak of mean dose time Dose Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Thickness of contaminated zone 5 0.13 4 0.00 5 0.07 4 0.00 Density of contaminated zone 7 0.04 6 0.00 6 0.05 5 0.00 Contaminated zone total porosity 11 0.03 7 0.00 7 0.04 6 0.00 Contaminated zone b parameter 19 -0.01 19 0.00 8 0.04 10 0.00 Evapotranspiration coefficient 6 0.05 11 0.00 14 0.02 16 0.00 Density of saturated zone 18 -0.02 13 0.00 11 -0.03 9 0.00 Saturated zone total porosity 16 -0.02 10 0.00 10 -0.03 8 0.00 Saturated zone hydraulic gradient 22 -0.01 22 0.00 17 0.01 20 0.00 Saturated zone b parameter 21 0.01 21 0.00 20 -0.01 21 0.00 Thickness of Unsaturated zone 1 12 -0.03 8 0.00 19 0.01 15 0.00 Density of Unsaturated zone 1 15 -0.02 9 0.00 18 0.01 12 0.00 Total Porosity of Unsaturated zone 1 17 -0.02 12 0.00 22 0.00 18 0.00 b Parameter of Unsaturated zone 1 9 0.04 15 0.00 12 0.03 13 0.00 Inhalation rate 3 0.91 3 0.00 3 0.54 3 0.00 Mass loading for inhalation 2 0.97 2 0.01 2 0.77 2 0.01 Indoor dust filtration factor 4 0.29 5 0.00 4 0.10 7 0.00 External gamma shielding factor 8 0.04 14 0.00 16 -0.01 19 0.00 Soil ingestion 1 1.00 1 1.00 1 1.00 1 1.00 Aquatic food 13 -0.02 17 0.00 21 0.01 22 0.00 Kd of Fe-55 in Contaminated Zone 10 -0.03 16 0.00 13 -0.03 14 0.00 Kd of Fe-55 in Unsaturated Zone 1 20 0.01 20 0.00 9 -0.03 11 0.00 Kd of Fe-55 in Saturated Zone 23 0.00 23 0.00 23 0.00 23 0.00 Fish transfer factor for Fe 14 -0.02 18 0.00 15 -0.02 17 0.00 H-3 Results:

RESRAD Regression and Correlation output 07/12/23 10:48 Page: Coef 1 Title : OCNGS Industrial Use_Probabilistic Analysis_H3 Input File : OC_IU_SA_H3.RAD Coefficients for peak of mean dose time Dose Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Thickness of contaminated zone 2 0.71 1 0.83 2 0.71 1 0.84 Density of contaminated zone 5 0.19 4 0.17 5 0.15 4 0.13 Contaminated zone total porosity 22 0.00 20 0.00 11 -0.04 7 -0.03 Contaminated zone b parameter 16 0.01 18 0.00 16 0.02 18 0.00 Evapotranspiration coefficient 3 0.63 3 0.22 3 0.59 3 0.20 Density of saturated zone 10 -0.03 6 -0.02 15 -0.02 9 -0.02 Saturated zone total porosity 13 -0.02 7 -0.02 22 -0.01 17 0.00 Saturated zone hydraulic gradient 8 0.03 10 0.01 21 0.01 22 0.00 Saturated zone b parameter 18 -0.01 19 0.00 8 -0.04 12 -0.01 Thickness of Unsaturated zone 1 23 0.00 21 0.00 19 -0.01 13 -0.01 Density of Unsaturated zone 1 19 0.01 15 0.01 10 0.04 6 0.03 Total Porosity of Unsaturated zone 1 17 0.01 12 0.01 12 0.03 8 0.02 b Parameter of Unsaturated zone 1 11 0.02 13 0.01 17 0.02 19 0.00 Inhalation rate 1 0.81 2 0.38 1 0.80 2 0.36 Mass loading for inhalation 6 0.05 8 0.01 7 0.05 11 0.01 Indoor dust filtration factor 15 -0.01 17 0.00 18 -0.01 20 0.00

BHI Engineering ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 24 of 28 External gamma shielding factor 21 0.00 23 0.00 13 0.02 15 0.01 Soil ingestion 9 -0.03 11 -0.01 14 -0.02 16 -0.01 Aquatic food 14 0.02 16 0.00 20 -0.01 21 0.00 Kd of H-3 in Contaminated Zone 4 -0.33 5 -0.10 4 -0.28 5 -0.08 Kd of H-3 in Unsaturated Zone 1 7 0.04 9 0.01 9 0.04 14 0.01 Kd of H-3 in Saturated Zone 12 0.02 14 0.01 6 0.06 10 0.02 Fish transfer factor for H 20 0.00 22 0.00 23 0.00 23 0.00 Mn-54 Results:

RESRAD Regression and Correlation output 07/12/23 10:58 Page: Coef 1 Title : OCNGS Industrial Use_Probabilistic Analysis_Mn54 Input File : OC_IU_SA_MN54.RAD Coefficients for peak of mean dose time Dose Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Thickness of contaminated zone 2 0.07 2 0.12 3 0.08 3 0.08 Density of contaminated zone 6 0.03 4 0.05 9 0.03 5 0.03 Contaminated zone total porosity 21 0.01 17 0.01 21 0.00 15 0.00 Contaminated zone b parameter 11 -0.02 14 -0.01 6 -0.04 10 -0.01 Evapotranspiration coefficient 18 0.01 21 0.01 18 0.01 20 0.00 Density of saturated zone 19 0.01 8 0.02 22 0.00 18 0.00 Saturated zone total porosity 22 0.00 19 0.01 16 -0.01 12 -0.01 Saturated zone hydraulic gradient 17 0.01 20 0.01 17 -0.01 19 0.00 Saturated zone b parameter 10 -0.02 13 -0.01 19 -0.01 21 0.00 Thickness of Unsaturated zone 1 14 -0.02 7 -0.03 7 -0.03 4 -0.03 Density of Unsaturated zone 1 4 0.03 3 0.05 10 0.03 6 0.03 Total Porosity of Unsaturated zone 1 12 0.02 5 0.03 12 0.03 7 0.03 b Parameter of Unsaturated zone 1 7 0.03 10 0.01 8 0.03 11 0.01 Inhalation rate 15 0.02 16 0.01 20 0.00 22 0.00 Mass loading for inhalation 13 -0.02 15 -0.01 14 -0.01 16 0.00 Indoor dust filtration factor 3 -0.06 6 -0.03 15 -0.01 17 0.00 External gamma shielding factor 1 0.84 1 0.83 1 0.94 1 0.93 Soil ingestion 16 0.01 18 0.01 11 0.03 13 0.01 Aquatic food 20 -0.01 22 0.00 23 0.00 23 0.00 Kd of Mn-54 in Contaminated Zone 5 0.03 9 0.02 2 0.28 2 0.10 Kd of Mn-54 in Unsaturated Zone 1 9 -0.02 12 -0.01 4 0.04 8 0.01 Kd of Mn-54 in Saturated Zone 8 0.02 11 0.01 5 0.04 9 0.01 Fish transfer factor for Mn 23 0.00 23 0.00 13 0.02 14 0.01 Nb-94 Results:

RESRAD Regression and Correlation output 07/10/23 16:01 Page: Coef 1 Title : OCNGS Industrial Use_Probabilistic Analysis_Nb94 Input File : OC_IU_SA_NB94.RAD Coefficients for peak of mean dose time Dose Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Thickness of contaminated zone 2 0.07 2 0.08 3 0.08 2 0.07 Density of contaminated zone 5 0.04 3 0.05 5 0.03 3 0.03 Contaminated zone total porosity 18 0.01 12 0.01 23 0.00 23 0.00 Contaminated zone b parameter 7 -0.03 9 -0.01 11 -0.02 13 -0.01 Evapotranspiration coefficient 21 0.00 21 0.00 22 -0.01 22 0.00 Density of saturated zone 14 0.01 7 0.01 18 -0.01 9 -0.01 Saturated zone total porosity 16 0.01 8 0.01 17 -0.01 8 -0.01 Saturated zone hydraulic gradient 10 -0.03 13 -0.01 16 -0.02 18 0.00 Saturated zone b parameter 9 -0.03 11 -0.01 12 -0.02 14 -0.01 Thickness of Unsaturated zone 1 6 -0.03 4 -0.04 6 -0.03 5 -0.02 Density of Unsaturated zone 1 20 0.01 18 0.01 9 0.03 7 0.02 Total Porosity of Unsaturated zone 1 19 0.01 17 0.01 8 0.03 6 0.02 b Parameter of Unsaturated zone 1 4 0.04 6 0.02 4 0.04 10 0.01 Inhalation rate 17 0.01 20 0.00 21 -0.01 21 0.00 Mass loading for inhalation 15 -0.01 19 0.00 19 -0.01 19 0.00 Indoor dust filtration factor 3 -0.06 5 -0.02 7 -0.03 11 -0.01 External gamma shielding factor 1 0.93 1 0.92 1 0.96 1 0.96 Soil ingestion 8 0.03 10 0.01 15 0.02 17 0.00 Aquatic food 22 0.00 22 0.00 20 -0.01 20 0.00 Fish transfer factor for Nb 23 0.00 23 0.00 14 0.02 16 0.00 Kd of Nb-94 in Contaminated Zone 11 -0.02 14 -0.01 2 0.10 4 0.03 Kd of Nb-94 in Unsaturated Zone 1 12 0.02 15 0.01 13 0.02 15 0.00 Kd of Nb-94 in Saturated Zone 13 0.02 16 0.01 10 0.03 12 0.01 Ni-63 Results:

RESRAD Regression and Correlation output 07/10/23 16:11 Page: Coef 1 Title : OCNGS Industrial Use_Probabilistic Analysis_Ni63 Input File : OC_IU_SA_NI63.RAD Coefficients for peak of mean dose time Dose Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Thickness of contaminated zone 5 0.06 3 0.01 5 0.07 3 0.02 Density of contaminated zone 19 0.00 13 0.00 15 0.01 8 0.00 Contaminated zone total porosity 9 -0.02 9 0.00 16 0.01 9 0.00 Contaminated zone b parameter 14 0.01 17 0.00 14 0.01 17 0.00 Evapotranspiration coefficient 10 -0.02 14 0.00 19 -0.01 20 0.00 Density of saturated zone 8 -0.04 6 -0.01 7 -0.04 6 -0.01 Saturated zone total porosity 7 -0.04 5 -0.01 6 -0.04 5 -0.01 Saturated zone hydraulic gradient 12 0.01 15 0.00 8 0.02 10 0.00

BHI Engineering ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 25 of 28 Saturated zone b parameter 13 0.01 16 0.00 10 0.02 13 0.00 Thickness of Unsaturated zone 1 15 -0.01 12 0.00 21 0.00 18 0.00 Density of Unsaturated zone 1 11 0.01 10 0.00 18 0.01 11 0.00 Total Porosity of Unsaturated zone 1 16 0.01 11 0.00 23 0.00 22 0.00 b Parameter of Unsaturated zone 1 22 0.00 22 0.00 11 0.02 14 0.00 Inhalation rate 3 0.13 4 0.01 4 0.11 7 0.01 Mass loading for inhalation 2 0.23 2 0.02 3 0.21 4 0.02 Indoor dust filtration factor 20 0.00 20 0.00 13 -0.01 16 0.00 External gamma shielding factor 17 -0.01 18 0.00 22 0.00 23 0.00 Soil ingestion 1 1.00 1 1.00 1 1.00 1 1.00 Aquatic food 21 0.00 21 0.00 20 0.00 21 0.00 Fish transfer factor for Ni 18 -0.01 19 0.00 12 -0.02 15 0.00 Kd of Ni-63 in Contaminated Zone 6 0.06 8 0.00 2 0.36 2 0.03 Kd of Ni-63 in Unsaturated Zone 1 23 0.00 23 0.00 9 -0.02 12 0.00 Kd of Ni-63 in Saturated Zone 4 -0.08 7 -0.01 17 -0.01 19 0.00 Np-237 Results:

RESRAD Regression and Correlation output 07/10/23 16:23 Page: Coef 1 Title : OCNGS Industrial Use_Probabilistic Analysis_Np237 Input File : OC_IU_SA_NP237.RAD Coefficients for peak of mean dose time Dose Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Kd of Np-237 in Contaminated Zone 3 0.20 4 0.14 3 0.61 3 0.32 Kd of Np-237 in Unsaturated Zone 1 8 0.04 11 0.03 13 0.03 17 0.01 Kd of Np-237 in Saturated Zone 16 -0.01 18 -0.01 24 0.01 26 0.01 Thickness of contaminated zone 5 0.12 3 0.26 6 0.15 4 0.19 Density of contaminated zone 11 0.03 8 0.06 30 0.00 29 0.00 Contaminated zone total porosity 27 0.01 16 0.01 16 -0.03 10 -0.04 Contaminated zone b parameter 15 0.02 17 0.01 20 -0.02 23 -0.01 Evapotranspiration coefficient 6 0.11 6 0.08 7 0.14 7 0.06 Density of saturated zone 14 -0.02 10 -0.04 11 -0.04 8 -0.05 Saturated zone total porosity 12 -0.03 9 -0.06 15 -0.03 9 -0.04 Saturated zone hydraulic gradient 13 0.02 14 0.02 9 0.04 13 0.02 Saturated zone b parameter 23 -0.01 26 -0.01 14 0.03 18 0.01 Thickness of Unsaturated zone 1 30 0.00 20 -0.01 22 -0.01 12 -0.02 Density of Unsaturated zone 1 24 0.01 15 0.02 28 0.01 21 0.01 Total Porosity of Unsaturated zone 1 31 0.00 27 0.01 25 -0.01 15 -0.01 b Parameter of Unsaturated zone 1 22 -0.01 25 -0.01 29 0.00 30 0.00 Inhalation rate 7 0.10 7 0.07 5 0.19 6 0.08 Mass loading for inhalation 4 0.18 5 0.13 4 0.32 5 0.14 Indoor dust filtration factor 9 0.04 12 0.03 10 0.04 14 0.02 External gamma shielding factor 2 0.47 2 0.37 2 0.72 2 0.44 Soil ingestion 1 0.59 1 0.51 1 0.85 1 0.67 Aquatic food 29 0.00 31 0.00 21 -0.01 24 -0.01 Fish transfer factor for Np 17 -0.01 19 -0.01 27 -0.01 28 0.00 Kd of Th-229 in Contaminated Zone 18 0.01 21 0.01 17 0.02 19 0.01 Kd of Th-229 in Unsaturated Zone 1 26 -0.01 29 0.00 12 -0.03 16 -0.01 Kd of Th-229 in Saturated Zone 25 0.01 28 0.00 26 0.01 27 0.00 Fish transfer factor for Th 10 0.03 13 0.02 8 0.04 11 0.02 Fish transfer factor for U 21 0.01 24 0.01 18 0.02 20 0.01 Kd of U-233 in Contaminated Zone 28 0.00 30 0.00 23 0.01 25 0.01 Kd of U-233 in Unsaturated Zone 1 19 0.01 23 0.01 19 -0.02 22 -0.01 Kd of U-233 in Saturated Zone 20 -0.01 22 -0.01 31 0.00 31 0.00 Pu-238 Results:

1 RESRAD Regression and Correlation output 07/10/23 16:42 Page: Coef 1 Title : OCNGS Industrial Use_Probabilistic Analysis_Pu238 Input File : OC_IU_SA_PU238.RAD Coefficients for peak of mean dose time Dose Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Thickness of contaminated zone 17 -0.02 7 0.00 24 -0.01 14 -0.01 Density of contaminated zone 21 0.02 10 0.00 37 0.00 29 0.00 Contaminated zone total porosity 19 0.02 9 0.00 40 0.00 38 0.00 Contaminated zone b parameter 29 0.01 30 0.00 7 -0.05 9 -0.01 Evapotranspiration coefficient 6 0.06 8 0.00 16 0.02 19 0.00 Density of saturated zone 36 -0.01 22 0.00 13 0.03 6 0.01 Saturated zone total porosity 40 0.00 38 0.00 11 0.03 5 0.01 Saturated zone hydraulic gradient 33 -0.01 34 0.00 26 0.01 27 0.00 Saturated zone b parameter 23 -0.01 24 0.00 29 0.01 31 0.00 Thickness of Unsaturated zone 1 15 -0.03 5 0.00 18 -0.02 12 -0.01 Density of Unsaturated zone 1 39 0.00 36 0.00 21 0.01 13 0.01 Total Porosity of Unsaturated zone 1 42 0.00 41 0.00 35 0.00 23 0.00 b Parameter of Unsaturated zone 1 28 -0.01 29 0.00 8 0.05 10 0.01 Inhalation rate 3 0.93 3 0.11 3 0.62 3 0.10 Mass loading for inhalation 2 0.98 2 0.23 2 0.84 2 0.20 Indoor dust filtration factor 4 0.34 4 0.02 4 0.12 4 0.02 External gamma shielding factor 20 0.02 21 0.00 23 -0.01 25 0.00 Soil ingestion 1 1.00 1 0.96 1 0.99 1 0.96 Aquatic food 12 -0.03 16 0.00 33 -0.01 35 0.00 Kd of Pu-238 in Contaminated Zone 18 0.02 20 0.00 10 0.04 15 0.01 Kd of Pu-238 in Unsaturated Zone 1 35 0.01 37 0.00 15 0.02 18 0.00 Kd of Pu-238 in Saturated Zone 43 0.00 43 0.00 17 0.02 20 0.00 Kd of Pb-210 in Contaminated Zone 27 0.01 28 0.00 14 -0.03 17 0.00 Kd of Pb-210 in Unsaturated Zone 1 34 -0.01 35 0.00 12 -0.03 16 0.00 Kd of Pb-210 in Saturated Zone 13 0.03 17 0.00 22 -0.01 24 0.00 Kd of Po-210 in Unsaturated Zone 1 38 0.00 40 0.00 43 0.00 43 0.00 Kd of Po-210 in Saturated Zone 31 0.01 32 0.00 28 -0.01 30 0.00 Kd of Ra-226 in Contaminated Zone 11 -0.03 15 0.00 39 0.00 40 0.00 Kd of Ra-226 in Unsaturated Zone 1 10 -0.04 14 0.00 36 0.00 37 0.00 Kd of Ra-226 in Saturated Zone 7 -0.05 11 0.00 41 0.00 41 0.00 Kd of Th-230 in Contaminated Zone 14 0.03 18 0.00 5 0.06 7 0.01 Kd of Th-230 in Unsaturated Zone 1 25 0.01 26 0.00 34 -0.01 36 0.00

BHI Engineering ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 26 of 28 Kd of Th-230 in Saturated Zone 16 0.02 19 0.00 38 0.00 39 0.00 Kd of U-234 in Contaminated Zone 8 -0.04 12 0.00 42 0.00 42 0.00 Kd of U-234 in Unsaturated Zone 1 9 0.04 13 0.00 9 0.05 11 0.01 Kd of U-234 in Saturated Zone 5 -0.07 6 0.00 20 0.02 22 0.00 Fish transfer factor for Pu 30 -0.01 31 0.00 31 0.01 33 0.00 Fish transfer factor for Pb 22 -0.01 23 0.00 25 0.01 26 0.00 Fish transfer factor for Po 24 -0.01 25 0.00 32 0.01 34 0.00 Fish transfer factor for Ra 26 -0.01 27 0.00 30 0.01 32 0.00 Fish transfer factor for Th 32 0.01 33 0.00 6 -0.06 8 -0.01 Fish transfer factor for U 41 0.00 42 0.00 27 0.01 28 0.00 Kd of Po-210 in Contaminated Zone 37 0.00 39 0.00 19 -0.02 21 0.00 Pu-239 Results:

RESRAD Regression and Correlation output 07/10/23 16:51 Page: Coef 1 Title : OCNGS Industrial Use_Probabilistic Analysis_Pu239 Input File : OC_IU_SA_PU239.RAD Coefficients for peak of mean dose time Dose Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Thickness of contaminated zone 17 0.02 9 0.05 4 0.23 1 0.46 Density of contaminated zone 10 -0.03 4 -0.10 26 0.01 13 0.02 Contaminated zone total porosity 15 -0.02 6 -0.08 30 -0.01 23 -0.01 Contaminated zone b parameter 18 -0.02 20 -0.02 27 -0.01 31 0.00 Evapotranspiration coefficient 9 -0.03 13 -0.03 35 0.00 35 0.00 Density of saturated zone 7 0.04 3 0.12 32 -0.01 24 -0.01 Saturated zone total porosity 6 0.04 2 0.14 23 0.01 12 0.02 Saturated zone hydraulic gradient 34 0.00 34 0.00 17 -0.02 20 -0.01 Saturated zone b parameter 32 0.00 32 0.00 16 -0.02 19 -0.01 Thickness of Unsaturated zone 1 28 -0.01 19 -0.02 28 -0.01 16 -0.01 Density of Unsaturated zone 1 29 0.00 24 -0.01 13 -0.02 8 -0.05 Total Porosity of Unsaturated zone 1 21 0.02 10 0.05 34 0.00 30 0.00 b Parameter of Unsaturated zone 1 19 0.02 21 0.02 14 0.02 17 0.01 Inhalation rate 20 -0.02 22 -0.02 19 0.02 22 0.01 Mass loading for inhalation 35 0.00 35 0.00 6 0.14 6 0.09 Indoor dust filtration factor 8 0.03 12 0.03 22 0.01 27 0.01 External gamma shielding factor 13 -0.03 16 -0.02 21 0.01 26 0.01 Soil ingestion 24 -0.01 26 -0.01 2 0.43 3 0.30 Aquatic food 5 0.05 11 0.05 10 0.05 11 0.03 Kd of Pu-239 in Contaminated Zone 4 -0.06 8 -0.06 1 0.57 2 0.44 Kd of Pu-239 in Unsaturated Zone 1 2 -0.08 5 -0.08 3 -0.34 4 -0.23 Kd of Pu-239 in Saturated Zone 3 -0.08 7 -0.08 5 -0.21 5 -0.14 Kd of Ac-227 in Contaminated Zone 12 -0.03 15 -0.03 25 -0.01 29 -0.01 Kd of Ac-227 in Unsaturated Zone 1 11 0.03 14 0.03 24 -0.01 28 -0.01 Kd of Ac-227 in Saturated Zone 26 -0.01 28 -0.01 11 0.03 14 0.02 Kd of Pa-231 in Contaminated Zone 14 -0.03 17 -0.02 31 -0.01 33 0.00 Kd of Pa-231 in Unsaturated Zone 1 31 0.00 31 0.00 7 0.09 7 0.06 Kd of Pa-231 in Saturated Zone 22 -0.01 23 -0.01 12 -0.02 15 -0.02 Kd of U-235 in Contaminated Zone 16 -0.02 18 -0.02 9 -0.05 10 -0.03 Kd of U-235 in Unsaturated Zone 1 23 0.01 25 0.01 15 -0.02 18 -0.01 Kd of U-235 in Saturated Zone 33 0.00 33 0.00 20 0.02 25 0.01 Fish transfer factor for Pu 1 0.15 1 0.14 8 0.05 9 0.03 Fish transfer factor for Ac 25 0.01 27 0.01 29 0.01 32 0.00 Fish transfer factor for Pa 27 -0.01 29 -0.01 18 -0.02 21 -0.01 Fish transfer factor for U 30 0.00 30 0.00 33 0.00 34 0.00 Pu-240 Results:

RESRAD Regression and Correlation output 07/10/23 17:01 Page: Coef 1 Title : OCNGS Industrial Use_Probabilistic Analysis_Pu240 Input File : OC_IU_SA_PU240.RAD Coefficients for peak of mean dose time Dose Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Thickness of contaminated zone 17 0.01 7 0.04 5 0.20 2 0.41 Density of contaminated zone 25 0.01 10 0.02 24 0.01 10 0.03 Contaminated zone total porosity 10 0.02 4 0.06 35 0.00 29 0.01 Contaminated zone b parameter 8 0.02 11 0.02 15 0.03 19 0.02 Evapotranspiration coefficient 9 -0.02 13 -0.02 9 0.04 13 0.02 Density of saturated zone 7 0.02 3 0.07 28 -0.01 14 -0.02 Saturated zone total porosity 6 0.03 2 0.10 27 -0.01 12 -0.03 Saturated zone hydraulic gradient 13 -0.02 17 -0.02 37 0.00 37 0.00 Saturated zone b parameter 16 0.01 20 0.01 14 0.03 18 0.02 Thickness of Unsaturated zone 1 37 0.00 36 0.00 12 -0.03 6 -0.06 Density of Unsaturated zone 1 31 -0.01 16 -0.02 36 0.00 30 -0.01 Total Porosity of Unsaturated zone 1 27 0.01 12 0.02 26 0.01 11 0.03 b Parameter of Unsaturated zone 1 12 -0.02 15 -0.02 13 0.03 17 0.02 Inhalation rate 20 0.01 23 0.01 8 0.05 9 0.03 Mass loading for inhalation 35 0.00 35 0.00 6 0.07 7 0.04 Indoor dust filtration factor 5 -0.03 9 -0.03 22 0.02 26 0.01 External gamma shielding factor 36 0.00 37 0.00 20 -0.02 24 -0.01 Soil ingestion 19 -0.01 22 -0.01 2 0.43 3 0.31 Aquatic food 18 0.01 21 0.01 7 -0.05 8 -0.03 Kd of Pu-240 in Contaminated Zone 4 -0.04 8 -0.04 1 0.54 1 0.42 Kd of Pu-240 in Unsaturated Zone 1 3 -0.05 6 -0.05 3 -0.29 4 -0.20 Kd of Pu-240 in Saturated Zone 2 -0.05 5 -0.05 4 -0.22 5 -0.14 Kd of Ra-228 in Contaminated Zone 21 -0.01 24 -0.01 11 0.04 16 0.02 Kd of Ra-228 in Unsaturated Zone 1 15 -0.01 19 -0.01 30 -0.01 32 -0.01 Kd of Ra-228 in Saturated Zone 32 0.01 32 0.01 23 0.01 27 0.01 Kd of Th-228 in Contaminated Zone 23 -0.01 26 -0.01 29 -0.01 31 -0.01 Kd of Th-228 in Unsaturated Zone 1 30 0.01 31 0.01 10 -0.04 15 -0.02 Kd of Th-228 in Saturated Zone 11 -0.02 14 -0.02 25 0.01 28 0.01 Kd of Th-232 in Contaminated Zone 29 -0.01 29 -0.01 18 0.02 22 0.01 Kd of Th-232 in Unsaturated Zone 1 26 -0.01 28 -0.01 31 -0.01 33 -0.01

BHI Engineering ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 27 of 28 Kd of Th-232 in Saturated Zone 14 -0.01 18 -0.01 19 -0.02 23 -0.01 Kd of U-236 in Contaminated Zone 28 -0.01 30 -0.01 38 0.00 38 0.00 Kd of U-236 in Unsaturated Zone 1 38 0.00 38 0.00 32 0.01 34 0.00 Kd of U-236 in Saturated Zone 34 0.00 34 0.00 21 -0.02 25 -0.01 Fish transfer factor for Pu 1 0.12 1 0.12 16 0.02 20 0.02 Fish transfer factor for Ra 24 -0.01 27 -0.01 17 0.02 21 0.02 Fish transfer factor for Th 33 0.00 33 0.00 33 -0.01 35 0.00 Fish transfer factor for U 22 -0.01 25 -0.01 34 -0.01 36 0.00 Pu-241 Results:

RESRAD Regression and Correlation output 07/10/23 18:02 Page: Coef 1 Title : OCNGS Industrial Use_Probabilistic Analysis_Pu241 Input File : OC_IU_SA_PU241.RAD Coefficients for peak of mean dose time Dose Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Kd of Am-241 in Contaminated Zone 4 0.12 7 0.05 3 0.44 3 0.17 Kd of Am-241 in Unsaturated Zone 1 18 -0.02 21 -0.01 20 0.02 22 0.01 Kd of Am-241 in Saturated Zone 33 0.00 33 0.00 34 -0.01 35 0.00 Kd of Np-237 in Contaminated Zone 15 -0.02 19 -0.01 14 0.03 18 0.01 Kd of Np-237 in Unsaturated Zone 1 19 0.02 22 0.01 25 0.01 26 0.00 Kd of Np-237 in Saturated Zone 39 0.00 39 0.00 23 0.02 24 0.01 Kd of Th-229 in Contaminated Zone 11 0.04 15 0.02 13 0.04 17 0.01 Kd of Th-229 in Unsaturated Zone 1 14 -0.03 18 -0.01 15 -0.03 19 -0.01 Kd of Th-229 in Saturated Zone 35 0.00 35 0.00 36 0.00 37 0.00 Kd of U-233 in Contaminated Zone 23 -0.01 25 -0.01 29 0.01 29 0.00 Kd of U-233 in Unsaturated Zone 1 29 -0.01 29 0.00 17 -0.02 20 -0.01 Kd of U-233 in Saturated Zone 27 -0.01 28 0.00 28 0.01 28 0.00 Fish transfer factor for Am 26 0.01 27 0.00 18 -0.02 21 -0.01 Fish transfer factor for Np 32 0.00 32 0.00 35 0.00 36 0.00 Fish transfer factor for Th 24 0.01 26 0.00 30 -0.01 30 0.00 Fish transfer factor for U 38 0.00 38 0.00 24 0.01 25 0.00 Thickness of contaminated zone 6 0.11 3 0.14 7 0.13 4 0.14 Density of contaminated zone 21 0.02 13 0.03 16 0.03 11 0.03 Contaminated zone total porosity 28 -0.01 20 -0.01 38 0.00 32 0.00 Contaminated zone b parameter 37 0.00 37 0.00 27 -0.01 27 0.00 Evapotranspiration coefficient 5 0.11 8 0.05 6 0.13 9 0.05 Density of saturated zone 10 -0.04 5 -0.06 12 -0.05 8 -0.05 Saturated zone total porosity 12 -0.04 6 -0.06 10 -0.05 7 -0.06 Saturated zone hydraulic gradient 36 0.00 36 0.00 21 -0.02 23 -0.01 Saturated zone b parameter 31 0.01 31 0.00 39 0.00 39 0.00 Thickness of Unsaturated zone 1 17 -0.02 11 -0.03 22 -0.02 14 -0.02 Density of Unsaturated zone 1 25 0.01 17 0.02 26 0.01 16 0.01 Total Porosity of Unsaturated zone 1 16 0.02 10 0.03 19 0.02 13 0.02 b Parameter of Unsaturated zone 1 20 -0.02 23 -0.01 37 0.00 38 0.00 Inhalation rate 3 0.19 4 0.08 5 0.22 6 0.08 Mass loading for inhalation 2 0.43 2 0.21 2 0.47 2 0.19 Indoor dust filtration factor 9 0.06 14 0.02 9 0.07 12 0.03 External gamma shielding factor 8 0.06 12 0.03 8 0.09 10 0.03 Soil ingestion 1 0.89 1 0.85 1 0.93 1 0.88 Aquatic food 30 0.01 30 0.00 32 0.01 33 0.00 Kd of Pu-241 in Contaminated Zone 7 0.09 9 0.04 4 0.28 5 0.10 Kd of Pu-241 in Unsaturated Zone 1 13 -0.04 16 -0.02 11 -0.05 15 -0.02 Kd of Pu-241 in Saturated Zone 22 -0.02 24 -0.01 33 -0.01 34 0.00 Fish transfer factor for Pu 34 0.00 34 0.00 31 0.01 31 0.00 Sb-125 Results:

RESRAD Regression and Correlation output 07/10/23 17:11 Page: Coef 1 Title : OCNGS Industrial Use_Probabilistic Analysis_Sb-125 Input File : OC_IU_SA_SB125.RAD Coefficients for peak of mean dose time Dose Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Thickness of contaminated zone 3 0.10 2 0.27 3 0.16 3 0.23 Density of contaminated zone 7 0.02 5 0.06 9 0.04 8 0.05 Contaminated zone total porosity 26 0.00 21 0.01 20 0.01 12 0.02 Contaminated zone b parameter 20 0.01 22 0.01 12 -0.03 14 -0.01 Evapotranspiration coefficient 4 0.10 4 0.08 4 0.16 4 0.07 Density of saturated zone 19 -0.01 11 -0.02 11 0.03 9 0.05 Saturated zone total porosity 25 0.00 16 -0.01 7 0.04 6 0.06 Saturated zone hydraulic gradient 14 -0.01 17 -0.01 16 -0.02 17 -0.01 Saturated zone b parameter 8 0.02 12 0.02 26 0.00 26 0.00 Thickness of Unsaturated zone 1 18 -0.01 9 -0.02 15 -0.02 10 -0.03 Density of Unsaturated zone 1 9 0.02 6 0.05 6 0.04 5 0.06 Total Porosity of Unsaturated zone 1 13 0.02 8 0.04 8 0.04 7 0.06 b Parameter of Unsaturated zone 1 11 0.02 14 0.02 18 0.01 19 0.01 Inhalation rate 21 0.01 23 0.01 19 0.01 20 0.01 Mass loading for inhalation 16 0.01 19 0.01 27 0.00 27 0.00 Indoor dust filtration factor 23 -0.01 25 0.00 13 0.02 15 0.01 External gamma shielding factor 1 0.41 1 0.39 1 0.85 1 0.72 Soil ingestion 22 0.01 24 0.01 22 0.01 22 0.00 Aquatic food 6 -0.03 10 -0.02 25 0.00 25 0.00 Kd of Sb-125 in Contaminated Zone 2 0.13 3 0.11 2 0.73 2 0.47 Kd of Sb-125 in Unsaturated Zone 1 15 0.01 18 0.01 23 0.01 23 0.00 Kd of Sb-125 in Saturated Zone 17 -0.01 20 -0.01 24 0.01 24 0.00 Kd of Te-125m in Contaminated Zone 5 -0.06 7 -0.05 21 -0.01 21 0.00 Kd of Te-125m in Unsaturated Zone 1 24 0.00 26 0.00 17 0.02 18 0.01 Kd of Te-125m in Saturated Zone 27 0.00 27 0.00 14 -0.02 16 -0.01 Fish transfer factor for Sb 12 -0.02 15 -0.01 10 0.03 13 0.02 Fish transfer factor for Te 10 -0.02 13 -0.02 5 -0.05 11 -0.02

BHI Engineering ENG-OCS-007 RESRAD-Onsite Probabilistic Analysis - Industrial Use Scenario Rev. 0 Page 28 of 28 Sr-90 Results:

RESRAD Regression and Correlation output 07/10/23 17:17 Page: Coef 1 Title : OCNGS Industrial Use_Probabilistic Analysis_Sr-90 Input File : OC_IU_SA_SR90.RAD Coefficients for peak of mean dose time Dose Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Thickness of contaminated zone 4 0.08 3 0.17 4 0.12 4 0.14 Density of contaminated zone 14 0.02 9 0.03 7 0.04 5 0.05 Contaminated zone total porosity 21 0.00 19 0.00 13 0.02 9 0.03 Contaminated zone b parameter 18 -0.01 18 0.00 18 -0.01 20 0.00 Evapotranspiration coefficient 5 0.05 10 0.03 5 0.07 7 0.03 Density of saturated zone 11 0.02 6 0.04 9 0.03 6 0.04 Saturated zone total porosity 17 0.01 14 0.02 14 0.02 10 0.03 Saturated zone hydraulic gradient 16 0.01 17 0.01 16 -0.02 16 -0.01 Saturated zone b parameter 19 0.00 20 0.00 20 0.00 21 0.00 Thickness of Unsaturated zone 1 13 -0.02 8 -0.03 19 0.00 17 -0.01 Density of Unsaturated zone 1 9 0.03 5 0.06 23 0.00 23 0.00 Total Porosity of Unsaturated zone 1 12 0.02 7 0.04 22 0.00 19 0.00 b Parameter of Unsaturated zone 1 20 0.00 21 0.00 10 0.03 12 0.01 Inhalation rate 10 0.02 15 0.01 12 0.02 14 0.01 Mass loading for inhalation 22 0.00 22 0.00 11 0.03 13 0.01 Indoor dust filtration factor 6 -0.05 11 -0.03 8 -0.04 11 -0.01 External gamma shielding factor 2 0.42 2 0.31 2 0.66 2 0.35 Soil ingestion 1 0.68 1 0.63 1 0.89 1 0.78 Aquatic food 23 0.00 23 0.00 15 -0.02 15 -0.01 Kd of Sr-90 in Contaminated Zone 3 0.14 4 0.09 3 0.59 3 0.29 Kd of Sr-90 in Unsaturated Zone 1 15 -0.01 16 -0.01 17 0.01 18 0.00 Kd of Sr-90 in Saturated Zone 7 0.04 12 0.03 6 0.07 8 0.03 Fish transfer factor for Sr 8 -0.03 13 -0.02 21 0.00 22 0.00 Tc-99 Results:

RESRAD Regression and Correlation output 07/10/23 17:24 Page: Coef 1 Title : OCNGS Industrial Use_Probabilistic Analysis_Tc-99 Input File : OC_IU_SA_TC99.RAD Coefficients for peak of mean dose time Dose Coefficient = PCC SRC PRCC SRRC Repetition = 1 1 1 1 Description of Probabilistic Variable Sig Coeff Sig Coeff Sig Coeff Sig Coeff Thickness of contaminated zone 5 0.10 3 0.20 4 0.19 3 0.29 Density of contaminated zone 22 0.00 19 0.00 10 0.04 8 0.06 Contaminated zone total porosity 14 -0.02 10 -0.05 19 -0.01 14 -0.01 Contaminated zone b parameter 10 -0.04 13 -0.02 18 0.01 21 0.00 Evapotranspiration coefficient 7 0.09 9 0.06 9 0.06 10 0.03 Density of saturated zone 20 0.00 18 0.00 21 0.00 19 -0.01 Saturated zone total porosity 23 0.00 21 0.00 15 -0.01 12 -0.02 Saturated zone hydraulic gradient 4 0.11 6 0.07 5 0.17 6 0.08 Saturated zone b parameter 18 0.00 20 0.00 16 -0.01 18 -0.01 Thickness of Unsaturated zone 1 13 -0.02 12 -0.04 8 -0.08 5 -0.12 Density of Unsaturated zone 1 11 0.03 8 0.06 14 -0.02 11 -0.02 Total Porosity of Unsaturated zone 1 9 0.04 4 0.08 20 0.01 15 0.01 b Parameter of Unsaturated zone 1 16 0.01 16 0.01 11 0.03 13 0.01 Inhalation rate 15 0.02 15 0.01 12 -0.02 16 -0.01 Mass loading for inhalation 21 0.00 23 0.00 17 0.01 20 0.00 Indoor dust filtration factor 17 0.01 17 0.01 13 -0.02 17 -0.01 External gamma shielding factor 19 0.00 22 0.00 23 0.00 23 0.00 Soil ingestion 12 0.03 14 0.02 22 0.00 22 0.00 Aquatic food 2 0.34 2 0.23 2 0.53 2 0.31 Kd of Tc-99 in Contaminated Zone 6 -0.09 7 -0.06 6 -0.12 7 -0.06 Kd of Tc-99 in Unsaturated Zone 1 3 -0.11 5 -0.07 3 -0.31 4 -0.16 Kd of Tc-99 in Saturated Zone 8 -0.07 11 -0.04 7 -0.10 9 -0.05 Fish transfer factor for Tc 1 0.71 1 0.66 1 0.80 1 0.67