Oyster Creek Generating Station Radiation Protection Calculation RP-OC-1001-09-005 Page 1 of 5 I.
Subject Disposition of Soil from Condensate Storage Transfer Pump House Excavation II.
Objective Document the rationale used for the decision to re-use the approximately 225 cubic yards of soil that was excavated as part of the pipe repair to mitigate the leakage of tritium to the environment under the condensate storage transfer pump house.
Ill.
Summary Micro-R meter results were equal to background (10 jiRem/hr), and direct frisk results were all
< 100 ccpm (corrected counts per minute). Twenty soil samples were taken at various depths as the excavation progressed. All sample gamma isotopic results showed either Natural Products, or a combination of Natural Products and Cesium 137 (Cs-137), Cobalt 60 (Co-60),
or Xenon 135 (Xe-1 35). (References C and D) Based on the analysis of these results, it was determined that the soil could be returned to the excavation site from which it came.
IV.
Data Results of Soil Samples from CST Area 2009 Natural Products Pb-212 Pb-214 TI-208 TI-210 Bi-21 1 Bi-214 Ac-228 K-40 Average Cs-1 37 cpCi
.£ i
1Lg 6.98E-08 0.07 8.47E-08 0.08 9.39E-08 0.09 9.73E-08 0.10 1.1OE-07 0.11 1.13E-07 0.11 1.21E-07 0.12 1.39E-07 0.14 1.46E-07 0.15 1.66E-07 0.17 1.72E-07 0.17 2.17E-07 0.22 2.18E-07 0.22 2.26E-O0:: 23 -
2.28E-0233 Co-60 alCi/ct 2.87E-07 2.97E-07 3.68E-07 9.62E-07 1.25E-06 1.35E-06 2.18E-06 2.58E-06 2.93E-06 3.53E-06 4,.72E-06 R-0/9 0,29 0.30 0.37 0.96 1.25 1.35 2.18 2.58 2.93 3.53 4.72 Xe-1 35 3.88E-08 0.04 1-95E-07 0.20 0.02 1.28
,*i*
Oyster Creek Generating Station Radiation Protection Calculation RP-OC-1001-09-005 Page 2 of 5 V.
Sample Counting All soil samples were counted as flowable solids (Reference A) to meet the Offsite Dose Calculation Manual (ODCM) environmental Lower Limit of Detection (LLDs) for sediment (Reference B). A mean count time of 1736 seconds and a median count time of 1448 seconds was needed to meet the Cs-134 and Cs-137 LLDs shown in the table below.
Isotope LLD pCi/Kg LLD pCi/g Cs-134 150 0.15 Cs-137 180 0.18 NOTE: Flowable solids are defined as material considered to be "free-flowing" in nature, including liquids, solids, sand, crushed asphalt and concrete, or oils that (as an aggregate) require a container to retain its shape in appropriate sample containers.
VI.
Sample Evaluation During 1991 Oyster Creek experienced a leak from the Condensate Storage Tank (CST),
which resulted in contamination of the soil surrounding the tank. This event was documented under the requirements of 50 CFR 75(g). No sample data was available from 1991, however, soil samples were taken'04/09/01 from the area around the CST, with the following results:
Natural Products K-40 Pb-212 Bi-214 Pb-214 Co-60 2.88E-6 to 8.1 E-5 gCi/g (or 2.88 to 81 pCi/g)
Cs-137 2.21 E-7 gtCi/g (or 0.221 pCi/g)
Cobalt 60 Co-60 has a radiological half-life of 5.27 years. As shown by the graph below, the Co-60 found in 2009 falls into the range expected (+ / - 2 standard deviations (a)) from the decay of the Co-60 seen eight (8) years ago in soil taken from approximately the same location. The median value from the range (2.88 to 81 pCi/g) found in 2001 was used (42 pCi/g) for the decay correction.
Oyster Creek Generating Station Radiation Protection Calculation RP-OC-1001-09-005 Page 3 of 5 Co-60 Decay 4D 35 25 015 5
-5 MAean 4
-2 5 -
2 a 0
Days 2960 s-Predicted Decay from 1991 *
- dian Value from 2009 Data F Cesium 137 Cs-1 37 has a radiological half-life of 30 years. The average activity found in the 2009 samples ranged from 0.07 to 0.23 pCi/g, compared to the decay corrected result of 0. 18 pCi/g from the 2001 sample. The 2009 Cs-137 data is consistent with the expected results. These results are also consistent with documented amounts of Cs-1 37 found as part of ambient background.
(See Appendix A)
Xenon-135 Xe-135 is a noble gas fission product having a radiological half-life of 9.1 hours1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. In Oyster Creek's steam-water cycle, steam containing various radionuclides passes from the reactor pressure vessel through the various turbine stages, and after condensing becomes condensate. This condensate is pumped to the condensate demineralizers where impurities, including radionuclides are removed. Almost all fission products are removed by the condensate demineralizers, and therefore they are not normally seen in the CST samples.
However, tritium and noble gases are not removed in the condensate demineralizers.
.While the condensate demineralizers do not remove noble gases, the steam-jet air ejectors (SJAE's) do remove most noble gases and other non-condensable gases prior to the condensate demineralizers. However, the SJAE's are not 100% efficient at removing all the noble gases.
in the steam-water cycle, downstream of the condensate demineralizers, the condensate can be directed to either feedwater or the CST.
Since Januaryl, 2009 Xe-1 35 has been found in the CST water three times in 23 samples.
,ince the soil samples were removed from the excavation site of the leak while the leak was a:ctive. it is not unexpected to see Xe-135 that was entrained in the CST water and
- ,bsequernily nrcorporated into the soil. Due to the short half-life,.*ny Xe-135 in the soil has
- ow decayed away.
Oyster Creek Generating Station Radiation Protection Calculation RP-OC-1001-09-005 Page 4 of 5 VII.
Conclusion Based on the survey and sample results, the soil can be returned to the excavation site from which it came. All survey results (direct frisk and micro-R meter) were "Non Detected (ND)"
above background. All sample gamma isotopic results showed either Natural Products, or a combination of Natural Products and Cs-1 37, Co-60, or Xe-i 35. Based on the analysis of these results, it was determined that the soil could be returned to the original site.
VIII.
References A.
CY-OC-130-511, Isotopic Analysis for Volumetric Waste Samples B.
CY-OC-171-301, Off Site Dose Calculation Manual C.
The Health Physics and Radiological Health Handbook, 1992 D.
The Gamma Rays of the Radionuclides, Tables for Applied Gamma Ray Spectrometry, 1979 IX.
Attachments
- a.
Appendix A - Background Cesium 137
- b.
Appendix B - Gamma Spectroscopy Results from 2009 Soil Samples
- c.
Appendix C - Survey QQQ-09-03617, Survey of CST Dirt Pile Prepared by:
Reviewed bv:
j" Date:.
Date:
/b Date:
(
\\k\\0 Approved by:
Oyster Creek Generating Station Radiation Protection Calculation RP-OC-1 001-09-005 Page 5 of 5 Appendix A Background Cesium 137 During January 2007, a report was prepared that evaluated soil and vegetation sample results from the Finninger Farm property. Significantly, this report described measured Cs-137 from New Jersey and property adjacent to the Oyster Creek site itself: "...,in the year 2000, as part of the confirmatory release survey for the adjacent Forked River site to the west of OCGS, the NRC reported that the maximum observed soil concentration of 0.53 pCi/g was not distinguishable from the variation in Cs-1 37 in the environment due to these fallout sources.
The NRC also reported background Cs-1 37 concentrations in New Jersey' coastal plain soils as high as 1.5 and 2.8 pCi/g. In addition, decay-corrected historic REMP data from a predominantly upwind location, nearly four miles from the OCGS, yields present-day Cs-i 37 concentrations ranging from 0.862 to 1.68 pCi/g." The highest reported sample re~itf i2' pCi/g is well below all of these numbers.
Additionally, a cesium background report was prepared February/March 2007 in order to support the above environmental project at the Oyster Creek site. The report described measured Cs-137 data from the New York area: "Following the Chernobyl event, Environmental Measurements Laboratory (EML) began a series of measurements on Long Island, NY. Post Chernobyl, EML reported 600 pCi/kg - 3,200 pCi/kg {of Cs-1 371 in surface soils on Long Island, near Oyster Bay, after decay correction, this represents about 60 to 1800 pCi/kg (0 - 5 cm) {depth} after decay to the present." This translates to 0.06 to 1.8 pCi/g.
-***,~**
~*********
- ***~*
GAMMA SPECTRUM ANALYSIS OYSTER CREEK NUCLEAR GENERATING STATION CHEMISTRY DEPARTMENT Detector Name
- DET01 Report Generated On Spectral Data File Name
\\2000049.CNF Sample Title Sample Description User ID Sample Type Sample Geometry Peak Locate Threshold Peak Locate Range (in channels)
Peak Area Range (in channels)
Identificatipn Energy Tolerance 4/17/09 2:06:19 PM C:\\PCNT2K\\CAMFILES\\1LSOLMDA I-L Solid Releas dirt
- 1 near cst kg 20 1-L Marinelli 3.00 1
4096 100 -
4096 1.000 keV Sample Size 1030.00 grams Sample Taken On Acquisition Started Decay Time Live Time Real Time Dead Time 4/17/09 1:10:33 PM 4/17/09 1:51:35 PM 4.10E+001 Minutes 1182.0 Seconds 1182.6 Seconds 0.05 %
Energy Calibration Used Done On Efficiency Calibration Used Done On 1/8/09 1/8/09
.~
Background Subtract Report 4/17/09 2:06:19 PM Page 2
B A C K G R O U N D S U B T R A C T R E P O R T "k***
Detector Name:
DET01 Sample
Title:
1-L Solid Releas Peak Analysis Performed on:
4/17/09 2:06:19 PM Peak Energy Subtracted No.
(keY)
Uncert.
1 238.40 1.29E+001 2
609.28 5.53E+000 3
1460.77 5.57E+000 Original Orig. Area Ambient Area Uncert.
Background
Backgr.
Uncert.
Subtracted Area 5.56E+001 2.38E+001 3.10E+001
- 5. 56E+001
- 2. 38E+001 3.10E+001 12.86 5.53 5.57 M = First peak in a multiplet region m +/- Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
Nuclide MDA Report 4/17/09 2:06:19 PM Page 3
NU C L I D E M D A R E P O R T Detector Name:
Sample Geometry:
Sample
Title:
Nuclide Library Used:
DET01 I-L Marinelli 1-L Solid Releas C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB Nuclide Activity Name (uCi/gram)
CS-134 7.72E-008 3.32E-008 4.20E-008 7.55E-008
- 8. 76E-008 6.94E-007 CS-137 6.85E-008 Energy (keV) 563.23 569.32 604.70 795.84 801.93 1365.15 661.65 Yield
(%)
8.38
- 15. 43
- 97. 60 85.40 8.73 3.04
- 85. 12 Line MDA (uCi/gram)
- 1. 12E-006
- 6. 54E-007
- 8. 16E-008
- 1. 94E-007 1.41E-006
- 4. 17E-006
+ = Nuclide identified during the nuclide identification
- = Energy line found in the spectrum
> = MDA value not calculated
@ = Half-life too short to be able to perform the decay correction
interference Corrected Activity Report 4/17/09 2:06:19 PM Page 4
N U C L I D E I D E N T I F I C A T IO N
R E P O R T Sample
Title:
1-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB IDENTIFIED NUCLIDES Nuclide Id Energy Name Confidence (keY)
K-40 1.000 1460.81*
PB-212 0.703 87.20
- 89. 80 238.63*
300.09 BI-214 0.662 609.31*
934. 06 1764.49 Yield
(%)
10.67 6.30 1.75 44.60 3.41 46.30 3.21 15.80 Activity (uCi/gram) 3.25E-006
- 2. 47E-007
- 2. 59E-007 Activity Uncertainty 5.89E-007 5.74E-008 6.07E-008
- = Energy line found :in the spectrum.
@ = Energy line not used for Weighted Mean Activity Energy Tolerance :
1.000 keV Nuclide confidence index threshold 0.30 Errors quoted at 1.000 sigma
Interference Corrected Activity Report 4/17/09 2:06:19 PM Page 5
S I N T E R F E R E N C E C O R R E C T E D R E P O R T Nuclide Name K-40 PB-212 BI-214 Nuclide Id Confidence 1.000 0.703 0.662 Wt mean Activity (uCi/gram) 3.25E-006 2.47E-007
- 2. 59E-007 Wt mean Activity Uncertainty 5.89E-007 5.74E-.008 6.07E-008 Total Activity 3.76E-006
? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.000 sigma U N I D E N T I F I E D P E A K S Peak Locate Performed on:
Peak Locate From Channel:
Peak Locate To Channel:
4/17/09 100 4096 2:06:19 PM Peak Energy No.
(keV)
Peak Size in Counts per Second Peak CPS
% Uncertainty All peaks were identified.
M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
~44* ********
- ~**
GAMMA SPECTRUM ANALYSIS OYSTER CREEK NUCLEAR GENERATING STATION CHEMISTRY DEPARTMENT Detector Name DET02 Report Generated On Spectral Data File Name
\\2000050.CNF Sample Title Sample Description User ID Sample Type Sample Geometry Peak Locate Threshold Peak Locate Range (in channels)
Peak Area Range (in channels)
Identification Energy Tolerance 4/17/09 2:26:17 PM C:\\PCNT2K\\CAMFILES\\1LSOLMDA 1-L Solid Releas dirt
- 2 near cst kg 20 1-L Marinelli 3.00 1-100 -
1.000 4096 4096 keV Sample Size 1066.00 grams Sample Taken On Acquisition Started Decay Time 4/17/09 1:10:15 PM 4/17/09 1:53:17 PM 4.30E+001 Minutes Live Time Real Time Dead Time 2278.0 Seconds 2278.9 Seconds 0.04 %
Energy Calibration Used Done On Efficiency Calibration Used Done On 3/21/08 3/21/08 Q
-,j
//
~>
ýZ,
,) f I
9115 -i/a,-
Background Subtract Report 4/17/09 2:26:17 PM Page BACKGROUND SUBTRACT REPORT
.4******.*****.****
999999 99 9999 99999999999999999999999 Detector Name:
DET02 Sample
Title:
1-L Solid Releas Peak Analysis Performed on:
4/17/09 2:26:17 PM Peak Energy Subtracted No.
(keY)
Uncert.
"tzmz*..
1 238.45 3.23E+001 Sb-zj4 2
295.01 2.48E+001 3
351.76 2.34E+001 4
583.20 1."78E+001 5
609.17 1.58E+001 6
661.66 1.77E+001 Lo-60O 7 1173.48 3.71E+001 8
1332.86 3.33E+001 v-*
9 1461.12 1.28E+001 Original Orig. Area Area Uncert.
Ambient
Background
Backgr.
Uncert.
- 1. 66E+002
- 8. 98E+001
- 1. 13E+002
- 6. 08E+001
- 7. 55E+001
- 1. 07E+002 1.21E+003
- 1. 05E+003 1.32E+002 32.31 24.76 23.40 17.77 15.77 17.70 37.13 33.25 12.76 Subtracted Area 1.66E+002 8.98E+001 1.13E+002 6.08E+001 7.55E+001 1.07E+002 1.21E+003 1.05E+003 1.32E+002 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
Nuc~lide MDA Report 4/17/09.
2:26:17 PM Page
.k **
NUCL IDE MDA REPOR.T Detector Name:
DET02 Sample Geometry:
1-L Marinelli Sample
Title:
1-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB Nuclide Activity Name (uCi/gram)
CS-134 3.27E-008 2.14E-007 2.06E-008 3.31E-008
- 3. 97E-007
.6.
+
- 2. 18E-007 Energy (keV) 563.23 569.32 604.70 795.84 801.93 1365.15 661.65*
Yield
(%)
8.38 15.43 97.60 85.A0 8.73 3.04 85.12 Line MDA (uCi/gram)
- 1. OOE-006 5.98E-007
- 9. 62E-008
- 1. 57E-007
- 1. 60E-006
= Nuclide identified during the'nuclide identification
- = Energy line found in the spectrum
> = MDA value not calculated
@ = Half-life too short to be able to perform the decay correction
interference Corrected Activity Report 4/17/09 2:26:17 PM Page 4
S N U C L I D E I D E N T I F I C A T IO N
R E P O R T Sample
Title:
1-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB IDENTIFIED NUCLIDES Nuclide Id Name Confidence Energy (keV)
K-40 0.984 1460.81*
CO-60 0.984 1173.22*
1332.49*
CS-137 1.000 661.65*
PB-212 0.670 87.20 89.80 238.63*
300.09 BI-214 0.659 609.31*
934.06 1764.49 PB-214 0.673 87.20 89.80 241.98 295.21*
351.92*
Yield
(%)
10.67 100.00 100.00 85.12 6.30 1.75 44.60 3.41 46.30 3.21 15.80 3.70 1.03 7.49 19.20 37.20 Activity (uCi/gram) 4.38E-006
- 3. 53E-006 3.41E-006
- 2. 18E-007 2.53E-007 2.62E-007
- 3. 83E-007 2.92E-007 Activity Uncertainty 4.34E-007 1.25E-007 1.28E-007 3.63E-008 4.97E-008 5.50E-008 1.06E-007 6.09E-008
- = Energy line found in the spectrum.
@ = Energy line-not used for Weighted Mean Activity Energy Tolerance :
1.000 keV Nuclide confidence index threshold =
0.30 Errors quoted at 1.000 sigma
Interference Corrected Activity Report 4/17/09 2:26:17 PM Page I N T E R F E R E N C E C O R R E C T E D.
R E P O R T
- 9*
- g**********
Nuclide Nuclide Id Name Confidence K-40 CO-60 CS-137 x
BI-211 PB-212 BI-214 PB-214 0.984 0.984 1.000 0.567 0.670 0.659 0.673 Wt mean Activity (uCi/gram)
- 4. 38E-006 3.47E-006
- 2. 18E-007
- 2. 53E-007
- 2. 62E-007
- 3. 14E-007 Wt mean Activity Uncertainty 4.34E-007 8.96E-008 3.63E-008 4.97E-008 5.50E-008 5.28E-008 Total Activity
- 8. 90E-006
?= nuclide is part of an undetermined solution x = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.000 sigma UNIDENTIFIED PEAKS Peak Locate Performed on:
Peak Locate From Channel:
Peak Locate To Channel:
4/17/09 100 4096 2:26:17 PM Peak Energy No.
(keY) 54 583.20 M = First peak in a
m = Other peak in a
F = Fitted singlet Peak Size in Counts per Second 2.67E-002 multiplet region multiplet region Peak CPS
% Uncertainty 29.22 Errors quoted at 1.000 sigma
~ ~*
GAMMA SPECTRUM ANALYSI S
OYSTER CREEK NUCLEAR GENERATING STATION CHEMISTRY DEPARTMENT Detector Name DET02 Report Generated On Spectral Data File Name
\\2000051.CNF Sample Title Sample Description User ID Sample Type Sample Geometry Peak Locate Threshold Peak Locate Range (in channels)
Peak Area Range (in channels)
Identification Energy Tolerance 4/17/09 3:15:44 PM C:\\PCNT2K\\CAMFILES\\ILSOLMDA 1-L Solid Releas dirt
- 3 near cst
- kg 20 1-L Marinelli 3.00 1 -
4096 100 -
4096 1.000 keV Sample Size 926.00 grams Sample Taken On Acquisition Started Decay Time 4/17/09 1:10:58 PM 4/17/09 2:49:01 PM 9.81E+001 Minutes Live Time Real Time Dead Time 1902.0 Seconds 1902.5 Seconds 0.03 %
Energy Calibration Used Done On Efficiency Calibration Used Done On 3/21/08 3/21/08 6
f PC-irjV I C-0 -(0 j t V c,/3-
B3ackground Subtract Report 4/17/09 3:15:45 PM Page BACKGROUND SUBTRACT REPORT
- 4*
Detector Name:
DET02 Sample
Title:
1-L Solid Releas Peak Analysis Performed on:
4/17/09 3:15:45 PM Peak Energy Subtracted No.
(keV)
Uncert.
-1 76.84 2.43E+001 2
238.50 2.73E+001
(
3 351.88 1.71E+001
-Z*
4 583.18 1.18E+001 3;.z, 5
609.24 1.48E+001 6
661.37
- 1. 38E+001 7
1173.50 2.68E+001 8
1332.75 2.36E+001 9
1460.97 9.21E+000 Original Orig. Area Area Uncert.
Ambient
Background
Backgr.
Uncert.
6.41E+001
- 1. 62E+002
- 9. 07E+001
- 4. 70E+001
- 9. 29E+001
- 3. 02E+001
- 6. 44E+002 5.28E+002
- 6. 75E+001 24.26 27.33 17.11 11 80 14.83 13.85 26.75 23.55 9.21 Subtracted Area 6.41E+001 1.62E+002 9.07E+001 4.70E+001 9.29E+001 3.02E+001 6.44E+002 5.28E+002 6.75E+001 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
Nuclide MDA Report I"/1"/09 3:15:45 PM Page 3
N U C L i D E M D A R E P 0 R T
- W*W*W**W*W*******
- WWWW***WW***W*W*************WW*W***
Detector Name:
Sample Geometry:
Sample
Title:
Nuclide Library DET02 1-L Marinelli 1-L Solid Releas Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB Nuclide Activity Name (uCi/gram)
CS-134 2.72E-007
- 8. 32E-008
- 7. 95E-007
- 3. 77E-008
+
- 8. 47E-008 Energy (keY) 563.23 569.32 604.70 795.84 801.93 1365.15 661.65*
Yield
(%)
8.38.
15.43 97.60 85.40 8.73 3.04 85.12 Line MDA (uCi/gram)
- 1. 05E-006
- 6. 18E-007
- 8. 86E-008
+ = Nuclide identified during the nuclide identification Energy line found in the spectrum
>= MDA value not calculated
@= Half-life too short to be able to perform the decay correction
Interference Corrected Activity Report 4
4/17/09 3:15:45 PM Page
-k N U C L I D E IDENTIFICATION REPORT Sample
Title:
1-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB IDENTIFIED NUCLIDES Nuclide Id Name Confidence Energy (keV)
K-40 0.996 1460.81*
CO-60 0.988 1173.22*
1332.49*
CS-137 0.988 661.65*
BI-211 0.548 351.10*
404.80 PB-212 0.672 87.20
.89.80 238.63*
300.09 BI-214 0.660 609.31*
934.06 1764.49 Yield
(%)
10.67 100.00 100.00 85.12 12.20 4.10 6.30 1.75 44.60 3.41 46.30 3.21 15.80 Activity (uCi/gram) 3.08E-006 2.58E-006 2.37E-006 8.47E-008
- 9. 88E-007 3.42E-007
- 4. 44E-007 Activity Uncertainty 4.26E-007 1.17E-007 1.16E-007 3.88E-008 1.88E-007 5.81E-008 7.16E-008
- = Energy line found in the spectrul
@ = Energy line not used for Weighte Energy Tolerance :
1.000 keV Nuclide confidence index threshold =
Errors quoted at 1.000 sigma M.
d Mean Activity 0.30
interference Corrected Activity Report 5
4/17/09 3:15:45 PM Page S
I N T E R F E R E N C E C O R R E C T E D R E P O R T Nuclide Nuclide Id Name Confidence K-40 CO-60 CS-137 BI-211 PB-212 BI-214 0.996 0.988 0.988 0.548 0.672 0.660 Wt mean Activity (uCi/gram) 3.08E-006 2. 47E-006 8.47E-008
- 9. 88E-007 3.42E-007 4.44E-007 Wt mean Activity Uncertainty 4.26E-007 8.23E-008 3.88E-008 1.88E-007 5.81E-008 7.16E-008 Total Activity 7.42E-006
? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.000 sigma U N I D E N T I F I E D P E A K S Peak Locate Performed on:
4/17/09 3:15:45 PM Peak Locate From Channel:
100 Peak Locate To Channel:
4096 Peak Energy No.
(keV) 1 76.84 4 583.18 M = First peak in a
m = Other peak in a
F = Fitted singlet Peak Size in Counts per Second 3.37E-002 2.47E-002 multiplet region multiplet region Peak CPS
% Uncertainty 37.85 125.11 Errors quoted at 1.000 sigma
GAMMA SPECTRUM ANAL SIM A NA LY S IS OYSTER CREEK NUCLEAR GENERATING STATION CHEMISTRY DEPARTMENT Detector Name
- DET02 Report Generated On Spectral Data File Name
',2000057.CNF Sample Title Sample Description User ID Sample Type Sample Geometry Peak Locate Threshold Peak Locate Range (in channels)
Peak Area Range (in channels)
Identification Energy Tolerance 4/18/09 1:54:41 PM C:\\PCNT2K\\CAMFILES\\ILSOLMDA 1-L Solid Releas Soil near CST; 3'
depth
- kg 20 1-L Marinelli 3.00 1 -
100 -
1.000 4096 4096 keV Sample Size 916.00 grams Sample Taken On Acquisition Started Decay Time 4/17/09 6:00:39 PM 4/18/09 1:17:41 PM 1.16E+003 Minutes Live Time Real Time Dead Time 2518.0 Seconds 2518.6 Seconds 0.02 %
Energy Calibration Used Done On Efficiency Calibration Used Done On 3/21/08 3/21/08
!t I,
7) h~c~
fl, 4j(
Background Subtract Report 4/18/09 1:54:41 PM Page
.W****
- w~
Detector Name:
DET02 Sample
Title:
1-L Solid Releas Peak Analysis Performed on:
4/18/09 1:54:41 PM Peak Energy Subtracted No.
(keV)
Uncert.
?b-Zlz-1 238.55 2.58E+001 2
351.79 2.03E+001 3
583.11 1.20E+001
" Z 4
609.35 1.34E+001 5
661.44 1.44E+001 6
969.71 1.10E+001 7
1173.52 2.83E+001 8
1332.95 2,.65E+001 9
1461.43 7.94E+000 Original Orig. Area Ambient Backgr.
Subtracted Area 8.93E+001
- 6. 56E+001
- 4. 83E+001 3.25E+001
- 6. 48E+001
- 1. 87E+001
- 7. 12E+002 6.31E+002
- 4. 56E+001 Uncert.
Background
Uncert.
Area 25.79, 20.27 11.95 13.39 14.37 11.00 28.31 26.51 7.94 8.93E+001 6.56E+001
- 4. 83E+001 3.25E+001
- 6. 48E+001
- 1. 87E+001
- 7. 12E+002 6.31E+002 4.56E+001 M = First peak in a multiplet region m
Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
Nuclide MDA Report 41118/09 1:54:42 PM Page 3
N U C L I D E M D A R E P 0 R T Detector Name:
Sample Geometry:
Sample
Title:
Nuclide Library DET02 I-L Marinelli 1-L Solid Releas Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB Nuclide Activity.
Name (uCi/gram)
CS-134
- 6. 52E-008
- 3. 54E-008
- 3. 96E-008
- 7. 24E-008 3.30E-007
- 3. 17E-007
+
CS-137 1.39E-007 Energy (kev) 563.23 569.32 604.70 795.84 801.93 1365.15 661.65*
Yield
(%)
8.38 15.43 97.60 85.40 8.73 3.04 85.12 Line MDA (uCi/gram)
- 9. 67E-007
- 4. 87E-007 8.14E-008 1.45E-007 1.20E-006 2.32E-006 i.24E-007 Nuclide MDA (uCi/gram) 8.14E-008 1.24E-007.
+ = Nuclide identified during the nuclide identification
- = Energy line found in the spectrum
>= MDA value not calculated
@= Half-life too short to be able to perform the decay correction
interference Corrected Activity Report 4/18,109 1:54:42-PM Page 4
N U C L I D E I D E N T I F I C A T I O N R E P O R T Sample
Title:
1-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB IDENTIFIED NUCLIDES Nuclide Id Energy Name Confidence (keV)
K-40 0.940 1460.81*
CO-60 0.976 1173.22*
1332.49*
CS-137 0.993 661.65*
BI-211 0.562 351.10*
404.80 PB-212 0.673 87.20 89.80 238.63*
6 300.09 BI-214 0.661 609.31*
934.06 1764.49 Yield
(%)
10.67 100.00 100.00 85.12 12.20 4.10 6.30 1.75 44.60 3.41 46.30 3.21 15.80 Activity (uCi/gram)
- 1. 59E-006
- 2. 18E-006
- 2. 16E-006
- 1. 39E-007 5.46E-007 1.44E-007 1.19E-007 Activity Uncertainty 2.79E-007 9.51E-008 1.01E-007 3.09E-008 1.69E-007 4.16E-008 4.90E-008
- = Energy line found in the spectrum.
= Energy line not used for Weighted Mean Activity Energy Tolerance :
1.000 keV Nuclide confidence index threshold =
0.30 Errors quoted at 1.000 sigma
interference Corrected Activity Report 4/18/09.
1:54:42 PM Page
.~**
INTERFERENCE CORRECTED REPORT
- ~
Nuclide Nuclide Id Name Confidence K-40 CO-60 CS-137 BI-211 PB-212 BI-214 0.940 0.976 0.993 0.562 0.673 0.661 Wt mean Activity (uCi/gram)
- 1. 59E-006 2.17E-006 1.39E-007 5.46E-007
- 1. 44E-007 1.19E-007 Wt mean Activity Uncertainty 2.79E-007 6.92E-008 3.09E-008 1.69E-007 4.16E-008 4.90E-008 Total Activity
- 4. 71E-006
? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.000 sigma U N I D E N T I F I E D P E A K S 1,:54:41 PM Peak Locate Performed on:
Peak Locate From Channel:
Peak Locate To Channel:
4/18/09 100 4096 Peak Energy No.
(keV) 3 583.11 969.71 M = First peak in a
m = Other peak in a
F = Fitted singlet Peak Size in Counts per Second 1.92E-002 7.42E-003 multiplet region multiplet region Peak CPS
% Uncertainty 24.75 58.89 Errors quoted at 1.000 sigma
4**~*******
- k~**'k***********
- ,~
~****
GAMMA SPECTRUM ANALYSI S
OYSTER CREEK NUCLEAR GENERATING STATION CHEMISTRY DEPARTMENT Detector Name
- DET02 Report Generated On Spectral Data File Name
\\2000059.CNF Sample Title Sample Description User ID Sample Type Sample Geometry Peak Locate Threshold Peak Locate Range (in channels)
Peak Area Range (in channels)
Identification Energy Tolerance 4/18/09 2:29:49 PM C:\\PCNT2K\\CAMFILES\\ILSOLMDA 1-L Solid Releas Soil near CST; 4' depth kg 20 1-L Marinelli 3.00 1 -
4096 100 -
4096 1.000 keY Sample Size 886.00 grams Sample Taken On Acquisition Started Decay Time 4/17/09 7:00:55 PM 4/18/09 2:07:58 PM 1.15E+003 Minutes Live Time Real Time Dead Time 1610.0 Seconds 1610.2 Seconds 0.01 %
Energy Calibration Used Done On Efficiency Calibration Used Done On 7,tol
,i(1 3/21/08 3/21/08
~'2
(~. 0-
- )
VJ--
Background Subtract Report
,'i 18/09 2:29:49 PM Page
- ,~************
.4 *******
BACKGROUND SUBTRACT REPORT Detector Name:
DET02 Sample
Title:
1-L Solid Releas Peak Analysis Performed on:
4/18/09 2:29:49 PM Peak Energy Subtracted No.
(keY)
Uncert.
I*-
1 238.44 1.70E+001 2
351.74
- D*
1.35E+001 4)?
3 583.13 6.15E+000 4
609.24 8.53E+000 5
661.57 7.61E+000 6
910.83 5.53E+000
/
7 1173.57 9.19E+000 6,-4o 8
1332.73 7.55E+000 g-'0 9
1461.39 6.89E+000 Original Orig. Area Area Uncert.
Ambient
Background
Backgr.
Uncert.
6.08E+001 4 87E+001
- 1. 76E+001
- 2. '4E+001 3.18E+001
- 1. 31E+001
- 5. 41E+001 5.36E+001
- 3. 53E+001.
16.95 13.45 6.15 8.53 7.61 5.53 9.19 7.55 6.89 Subtracted Area 6.08E+001 4.87E+001 1.76E+001 2.74E+001 3.18E+001 1.31E+001 5.41E+001 5.36E+001 3.53E+001 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
Nuclide MDA Report 4/18/09 2:29:50 PM Page 3
N U C L i D E M D A R E P 0 R T Detector Name:
DET02 Sample Geometry:
I-L Marinelli Sample
Title:
1-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB Nuclide Activity Name (uCi/gram)
Energy (key)
Yield
(%)
Line MDA (uCi/gram)
Nuclide MDA (uCi/gram)
CS-134 563.23 8.38 5.29E-007 7.84E-00 1.19E-007 569.32 15.43 4.08E-007 1.57E-007 604.70 97.60 7.84E-008 1.19E-008 795.84 85.40 9.16E-008 7.56E-010 801.93 8.73 8.09E-007 9.00E-008 1365.15 3.04 3.51E-006 1.01E-006
+
CS-137 661.65*
85.12 9.15E-008 9.15E-001 1.10E-007
+ = Nuclide identified during the nuclide identification'
- = Energy line found in the spectrum
> = MDA value not calculated
@ = Half-life too short to be able to perform the decay correction 8
8
Interference Corrected Activity Report 4/18/09 2:29:50 PM Page 4
- U*C*L*I*D*E*I***E*N*T*IF**
IC*AW**1**N******RE******
P0R
- <N U C L IDE ID E NT IFiC AT I ON R E POR T
Sample
Title:
1-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB IDENTIFIED NUCLIDES Nuclide Id Energy Name Confidence (keV)
K-40 0.947 1460.81*
CO-60 0.985 1173.22*
1332.49*
CS-137 0.999 661.65*
BI-211 0.569 351.10*
404.80 PB-212 0.670 87.20
- 89. 80 238.63*
300.09 BI-214 0.660 609.31*
934.06 1764;49 Energy line found in Energy line not used Energy Tolerance Nuclide confidence index Errors quoted at 1.000 Yield Activity
(%)
(uCi/gram) 10.67 100.00 100.00 85.12 12.20 4.10 6.30 1.75 44.60 3.41
.46.30 3.21 15.80
- 1. 99E-006
- 2. 68E-007 2.97E-007
- 1. IOE-007
- 6. 55E-007
- 1. 58E-007
- 1. 62E-007 Activity Uncertainty 3.91E-007 4.57E-008 4.23E-008 2.64E-008 1.82E-007 4.42E-008 5.05E-008 the spectrum.
for-Weighted Mean Activity 000 keY threshold =
sigma 0.30
Interference Corrected Activity Report 4/18/09 2:29:50 PM.
Page 5
I NT E RF E RE NCE C ORR EC T ED R E PO RT Nuclide Nuclide Id Name Confidence K-40 CO-60 CS-137 BI-211 PB-212 BI-214 0.947 0.985 0.999 0.569 0.670 0.660 Wt mean Activity (uCi/gram)
- 1. 1OE-007
- 6. 55E-007
- 3. 91E-007 3.10E-008
- 2. 64E-008
- 1. 82E-007
- 4. 42E-008 5.05E-008 Total Activity 3.36E-006
? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.000 sigma SU N I D E N T I F I E D P E A K S Peak Locate Performed on:
Peak Locate From Channel:
Peak Locate To Channel:
4/18/09 100 4096 2:29:49 PM Peak Energy No.
(keY) 3 6
583.13 910.83 Peak Size in Counts per Second 1.09E-002 8.16E-003 multiplet region multiplet region Peak CPS
% Uncertainty 34.93 42.08 M = First peak in a
m = Other peak in a
F = Fitted singlet Errors quoted at 1.000 sigma
- 4*
- *4 GAMMA SPECTRUM A N A L Y S I S
OYSTER CREEK NUCLEAR GENERATING STATION CHEMISTRY DEPARTMENT Detector Name
- DET01 Report Generated On Spectral Data File Name
\\2000056.CNF Sample Title Sample Description User ID Sample Type Sample Geometry Peak Locate Threshold Peak Locate Range (in channels)
Peak Area Range (in channels)
Identification Energy Tolerance 4/18/09 1:36:-19 PM C:\\PCNT2K\\CAMFILES\\ILSOLMDA
- I-L Solid Releas Soil nearCST; 2'
depth kg 20 1-L Marinelli 3.00 1 -
100 -
1.000 4096 4096 keV Sample Size 940.00 grams Sample Taken On Acquisition Started Decay Time 4/17/09 8:00:18 PM 4/18/09 1:11:20 PM 1.03E+003 Minutes 1796.0 Seconds 1797.1 Seconds 0.06 %
Live Time Real Time Dead Time Energy Calibration Used Done On Efficiency Calibration Used Done On 1/8/09 1/8/09 e..
eW*2 "
i~2i
/
/ ~,
V~i-/37
Background Subtract Report 4/18/09 1:36:19 PM Page 2
B A C K G R 0 U N D S U B T R A C T R E P O R T Detector Name:
DET01 Sample
Title:
1-L Solid Releas Peak Analysis Performed on:
4/18/09 1:36:19 PM Peak Energy Subtracted No.
(keY)
Uncert.
Z 1
238.55 1.72E+001 zcý,
2 582.92 8.71E+000 3
-7 3
661.33 8.75E+000 o-evo 4
1172.72 1.62E+001 5 1332.20 1.24E+001 6 1460.20 6.03E+000 Original Orig. Area Area Uncert.
Ambient
Background
Backgr.
Uncert.
- 7. 17E+001
- 1. 50E+001 3.15E+001
- 1. 89E+002 1.38E+002 3.25E+001 17.15 8.71 8.75 16.16 12.43 6.03 Subtracted Area
- 7. 17E+001 1.50E+001 3.15E+001
- 1. 89E+002 1.38E+002 3.25E+001 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
Nuclide IMDA Report 4/18/09 1:116:19 PM Page 3
N U C L I D E M D A R E P O R T Detector Name:
Sample Geometry:
Sample
Title:
Nuclide Library DET01 1-L Marinelli 1-L Solid Releas Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB Activity (uCi/gram)
Nuclide Name CS-134 4.73E-007
- 7. 60E-008
- 5. 15E-008
- 8. IIE-009
+
CS-137 1.46E-007 Energy (keY) 563.23 569.32 604.70 795.84 801.93 1365.15 661.65*
Yield
(%)
8.38 15.43 97.60 85.40 8.73 3.04 85.12 Line MDA (uCi/gram) 1.14E-006
- 8. 02E-007
+ = Nuclide identified during the nuclide identification
- =
Energy line found in the spectrum
> = MDA value not calculated
@ = Half-life too short to be able to perform the decay correction
Interference Corrected Activity Report 4/18/09 1:36:19 PM Page 4
N U C L I D E I D E N T I F I C A T I ON R E P O R T Sample
Title:
1-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB IDENTIFIED NUCLIDES Nuclide Id Energy Name Confidence (keY)
K-40 CO-60 CS-137 PB-212 0.942 1460.81*
0.975 1173.22*
1332.49*
0.984 661.65*
0.709 87.20 89.80 238.63*
300.09 Yield
(%)
10.67 100.00 100.00 85.12 6.30 1.75 44.60 3.41 Activity (uC i /gram) 2.46E-006 1.25E-006
- 1. 03E-006 1.46E-007
\\2 2.30E-007 Activity Uncertainty 4.60E-007 1.10E-007 9.48E-008 4.07E-008 5.52E-008
- = Energy line found in the spectrum.
@ = Energy line not used for Weighted Mean Activity Energy Tolerance :
-1.000 keV
/
Nuclide confidence index threshold =
0.30 Errors quoted at 1.000 sigma
!ýterference Corrected Activity Report 4/18/09, 1:36:19 PM Page 5
I NT ER FE RE N CE C OR R EC TED R E POR T
Nuclide Nuclide Id Name Confidence Wt mean Activity (uCi/gram) 2.46E-006 1.13E-006 1.46E-007 2.30E-007 Wt mean.
Activity Uncertainty 4.60E-007 7.18E-008 4.07E-008 5.52E-008 K-40 C0-60 CS-137 PB-212 0.942 0.975 0.984 0.709 Total Activity 3.96E-006
= nuclide is part of an undetermined solution x = nuclide rejected by the interference analysis
@= nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.000 sigma U N I D E N T I F I E D P E A K S Peak Locate Performed on:
Peak Locate From Channel:
Peak Locate To Channel:
4/18/09 100 4096 1:36:19 PM Peak Energy No.
(keY) 2 582.92 M = First peak in a
m = Other peak in a
F = Fitted singlet Peak Size in Counts per Second 8.35E-003 multiplet region multiplet region Peak CPS
% Uncertainty 58.07 Errors quoted at 1.000 sigma
+***********************************
- ~
GAMMA SPECTRUM ANALYSI S
OYSTER CREEK NUCLEAR GENERATING STATION CHEMISTRY DEPARTMENT Detector Name
- DET02 Report Generated On Spectral Data File Name
\\2000054.CNF Sample Title Sample Description User ID Sample Type Sample Geometry Peak Locate Threshold Peak Locate Range (in channels)
Peak Area Range (in channels)
Identification Energy Tolerance Sample Size Sample Taken On Acquisition Started Decay Time 4/18/09 11:16:54 AM C:\\PCNT2K\\CAMFILES\\ILSOLMDA 1 -L Solid Releas Soil sample near CST; 4'
- kg 20 1-L Marinelli 3.00 1 -
4096 100 -
4096 1.000 keV 916.00 grams 4/17/09 11:00:17 PM 4/18/09 10:54:19 AM 7.14E+002 Minutes 1653.0 Seconds 1653.3 Seconds 0.02 %
Live Real Dead Time Time Time Energy Calibration Used Done On Efficiency Calibration Used Done On 3/21/08 3/21/08
'au I ek) ed 4V (3/46o
Background Subtract Report 2
a4/18/09 11:16:55 AM Page B A C K G R O U N D S U B T R A C T R E P O R T Detector Name:
DET02 Sample
Title:
1-L Solid Releas Peak Analysis Performed on:
4/18/09 11:16:54 AM Peak Energy Subtracted No.
(keY)
Uncert.
-Z/2-1 238.30 1.72E+001
,Zj 2
351.63 1.34E+001
ý0 3
1173.63 1.83E+001 4
1332.90 1.58E+001
(-0o 5
1461.17 7.29E+000 Original Orig. Area Ambient Backgr.
Area Uncert.
Background
Uncert.
- 6. 55E+001
- 4. 93E+001
- 2. 90E+002 2.32E+002 4.35E+001 17.24 13.38 18.27 15.76 7.29 Subtracted Area 6.55E+001 4.93E+00,1 2.90E+002.
2.32E+002 4.35E+001 M = First peak m = Other peak in a multiplet region in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
Nuclide MDA Report 3
4/18/09 11:16:55 AM Page N U C L I D E M D A R E P O R T Detector Name:
DET02 Sample Geometry:
1-L Marinelli Sample
Title:
1-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB Nuclide Activity Name (uCi/gram)
CS-134
- 1. 02E-007
- 2. 04E-007
- 1. 40E-008 2.88E-008 1.99E-007 1.76E-007 CS-137 1.21E-007 Energy (keV) 563.23 569.32 604.70 795.84 801.93 1365.15 661.65 Yield
(%)
8.38 15.43 97.60 85.40 8.73 3.04 85.12 Line MDA (uCi/gram)
- 1. 07E-006
- 4. 68E-007
- 9. 67E-008 1.32E-007
+ = Nuclide identified during the nuclide identification
- = Energy line found in the spectrum
> = MDA value not calculated
@ = Half-life too short to be able to perform the decay correction
- interference Corrected Activity Report 4/18/09 1-1:16:55 AM Page 4
N NUCL I DE I DE NT I FIC A TIO0N R E POR T
Sample
Title:
I-L Solid'Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB IDENTIFIED NUCLIDES Nuclide Id Name Confidence Energy (keV)
K-40 0.980 1460.81*
CO-60 0.973 1173.22*
1332 49*
BI-211 0.584 351.10*
404.80 PB-212 0.661 87.20 89.80 238.63*
300.09 Yield
(%)
10.67 100.00 100.00 12.20 4.10 6.30 1.75 44.60 3.41 Activity (uCi/gram) 2.31E-006 1.35E-006 1.21E-006 6.25E-007
- 1. 60E-007 Activity Uncertainty 3.91E-007 8.86E-008 8.59E-008 1.70E-007 4.24E-008
- = Energy line found in the spectrum.
@ = Energy line not used for Weighted Mean Activity Energy Tolerance :
1.000 keV Nuclide confidence index threshold =
0.30 Errors quoted at' 1.000 sigma
Interference Corrected Activity Report 5
4/18,'09 11:16:55 AM Page
- I N TE R F E R E N C E C O R R E C T E D R E P O R T
- 9 9 *% *
- 99 *
- * *999
- 9 99 Nuclide Nuclide Id Name Confidence Wt mean Activity (uCi/gram) 2.31E-006 1.28E-006
- 6. 25E-007
- 1. 60E-007 Wt mean Activity Uncertainty 3.91E-007 6.17E-008 1.70E-007 4.24E-008 K-40 CO-60 BI-211 PB-212 0.980 0.973
- 0. 584 0.661 Total Activity
- 4. 38E-006
? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.000 sigma U N I D E N T I F I E D P E A K S Peak Locate Performed on:
Peak Locate From Channel:
Peak Locate To Channel:
4/18/09 100 4096 11:16:54 AM Peak Energy No.
(keV)
Peak Size in Counts per Second Peak CPS
% Uncertainty All peaks were identified.
M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
- 44***************
GAMMA SPECTRUM ANALY SI S
OYSTER CREEKNUCLEAR GENERATING STATION CHEMISTRY DEPARTMENT Detector Name
- DET01 Report Generated On Spectral Data File Name
\\2000055.CNF Sample Title Sample Description User ID Sample Type Sample Geometry 4/18/09 12:46:34 PM C:\\PCNT2K\\CAMFILES\\lLSOLMDA 0
1-L Solid Releas Soil near CST; 5' depth kg 20 1-L Marinelli Peak Locate Threshold Peak Locate Range (in channels)
Peak Area Range (in channels)
Identification Energy Tolerance 3.00 1 -
4096 100 -
4096 1.000 keV Sample Size 834.00 grams Sample Taken On Acquisition Started Decay Time 4/18/09 12:00:38"AM 4/18/09 12:05:41 PM 7.25E+002 Minutes Live Time Real Time Dead Time 2750.0 Seconds 2751.5 Seconds 0.05 %
Energy Calibration Used Done On Efficiency Calibration Used Done On ij
ý-"j'07*
1/8/09 1/8/09 I
I
/
Vi-
Background Subtract Report 4/18/09 12:46:34 PM Page B A C K G R O U N D S U B T R A C T R E P O R T Detector Name:
DET01 Sample
Title:
I-L Solid Releas Peak Analysis Performed on:
4/18/09 12:46:34 PM Peak Energy Subtracted No.
(keV)
Uncert.
3>zI~
1 351.83 1.30E+001 2
609.13 9.20E+000 1/3-3 660.87 9.75E+000 4
910.94 1.04E+001 Co' 60 5
1172.86 1.51E+001 6
1332.10 1.42E+001 7
1461.02 7.20E+000 Original Orig. Area Area Uncert.
Ambient Backgr.
Background
Uncert.
- 4. 81E+001 3.43E+001 2.75E+001
- 2. 80E+001 1.73E+002 1.76E+002
- 4. 05E+001 12.96 9.20 9.75 10.37 15.06 14.22 7.20 Subtracted Area 4.81E+001 3.43E+001 2.75E+001.
2.80E+001 1.73E+002 1.76E+002 4.05E+001 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
Nuaclide MDA Report 4/18/09 12:46:35 PM Page 3
N U C L I D E M D A R E P O R T Detector Name:
DET01 Sample Geometry:
1-L Marinelli Sample
Title:
1-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB Activity (uCi/gram)
Nuclide Name CS-134 2.60E-007
- 3. 02E-007
- 2. 73E-009
- 2. 57E-008
- 3. 21E-007
- 0. OOE+O000
+
- 9. 39E-008 Energy (keV) 563.23 569.32 604.70 795.84 801.93 1365. 15 661.65*
Yield
(%)
8.38 15.43 97.60 85.40 8.73 3.04 85.12 Line MDA (uCi/gram) 1.08E-006 4.99E-007
- 1. 02E-007 1.59E-007
- 1. 37E-006
+ = Nuclide identified during the nuclide identification
- = Energy line found in the spectrum
> = MDA value not calculated
@ = Half-life too short to be able to perform the decay correction
Interference Corrected Activity Report 4
4/18/09 12:46:35 PM Page N U C L I D E I D E N T I F I C A T I O N R E P O R T Sample
Title:
1-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB IDENTIFIED NUCLIDES Nuclide Id Name Confidence Energy (keV)
K-40 0.993 1460.81*
CO-60 0.978 1173.22*
1332.49*
CS-137 0.907 661.65*
BI-211 0.558 351.10*
404.80 BI-214 0.659 609.31*
934.06 1764.49 Yield
(%)
10.67 100.00 100.00 85.12 12.20 4.10 46.30 3.21 15.80 Activity (uCi/gram) 2.26E-006 8.46E-007
- 9. 62E-007 9.39E-008 6.06E-007 1. 99E-007 Activity Uncertainty 4.05E-007 7.53E-008 8.03E-008 3.33E-008 1.64E-007 5.35E-008
- = Energy line found in the spectrum.
@ = Energy line not used for Weighted Mean Activity Energy Tolerance :
1.000 keV Nuclide confidence index threshold =
Errors quoted at 1.000 sigma 0.30
.Interterence Corrected Activity Report 4/18/09 12:46:35 PM Page 5
S I N T E R F E R E N C E C O R R E C T E D R E P O R T Nuclide Nuclide Id Name Confidence K-40 CO-60 CS-137 BI-211 BI-214 0.993 0.978 0.907 0.558 0.659 Wt mean Activity (uCi/gram) 2.26E-006
- 9. OOE-007
- 9. 39E-008
- 6. 06E-007
- 1. 99E-007 Wt mean Activity Uncertainty 4.05E-007 5.49E-008 3.33E-008 1.64E-007 5.35E-008 Total Activity 4.05E-006
? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.000 sigma S
U N I D E N T I F I E D P E A K S Peak Locate Performed on:
Peak Locate From Channel:
Peak Locate To Channel:
4/18/09 100 4096 12:46:34 PM Peak Energy No.
(keY) 4 910.94 M
First peak in a m = Other peak in a
F= Fitted singlet Peak Size in Counts per Second 1.02E-002 multiplet region multiplet region Peak CPS
% Uncertainty 36.98 Errors quoted at 1.000 sigma
- ýý* ***
4 -k *
- -k*
GAMMA SPECTRUM ANALYSI S
OYSTER CREEK NUCLEAR GENERATING STATION CHEMISTRY DEPARTMENT Detector Name
- DET01 Report Generated On Spectral Data File Name
\\2000053.CNF Sample Title Sample Description User ID Sample Type Sample Geometry Peak Locate Threshold Peak Locate Range (in channels)
Peak Area Range (in channels)
Identification Energy Tolerance 4/18/09 11:52:55 AM C:\\PCNT2K\\CAMFILES\\ILSOLMDA 1-L Solid Releas Soil sample near CST; 6' kg 20 1-L Marinelli 3.00 1-100 -
1.000 4096 4096 keV Sample Size 1239.00 grams Sample Taken On Acquisition Started Decay Time 4/18/09 4:50:18 AM 4/18/09 10:50:20 AM 3.60E+002 Minutes Live Time Real Time Dead Time 4044.0 Seconds 4046.7 Seconds 0.07 %
Energy Calibration Used Done On Efficiency Calibration Used Done On
'eut we'i
(>(Jt 1/8/09 1/8/09 I
/
/ (0-62J '/6
Background Subtract Report 4/18/09 11:52:59 AM Page B A C KG R OU ND S U BT RA CT R E POR T.
Detector Name:
DET01 Sample
Title:
I-L Solid Releas Peak Analysis Performed on:
4/18/09 11:52:59 AM Peak Energy Subtracted No.
(keV)
Uncert.
?b-z/2 1
238.66 bvI 3.89E+001 2
295.14 2.25E+001
, z11 3
351.55 2.46E+001 2
4 608.85 2.00E+001 5
661.22 2.12E+001 6
1172.84 3.83E+001 7
1332.18 3.49E+001 Original Orig. Area Area Uncert.
Ambient
Background
Backgr.
Uncert.
1.36E+002
- 3. 63E+001
- 7. 50E+001 6.98E+0o1
- 1. 44E+002
- 1. 19E+003
- 1. 17E+003 38.86 22.50 24.64 19.97 21.21 38.28 34.90 Subtracted Area 1.36E+002 3.63E+001 7.50E+001 6.98E+001 1.44E+002 1.19E+003 1.17E+003 M = First peak in a multiplet region m = Other peak in F = Fitted singlet a multiplet region Errors quoted at 1.000 sigma
NUClide MDA Report 4u18/09 11:53:00 AM Page
- ***~************
- ~***
NUCLIDE MDA REPORT Detector Name:
Sample Geometry:
Sample
Title:
Nuclide Library DETOl 1-L Marinelli 1-L Solid Releas Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB Nuclide Activity Name (uCi/gram)
CS-134 1.46E-007 1.16E-008 5.91E-010 1.01E-008 1.91E-007 1.37E-007
+
CS-137 2.26E-007 Energy (keY) 563.23 569.32 604.70 795.84 801.93 1365.15 661.65*
Yield 8.38 15.43 97.60 85.40 8.73 3.04 85.12 Line MDA (uCi/gram)
- 9. 56E-007
- 5. 68E-007
- 8. 48E-008 1.39E-007
+ = Nuclide identified during the nuclide identification
- = Energy line found in the spectrum
> = MDA value not calculated
@ = Half-life too short to be able to perform the decay correction
Interference Corrected Activity Report 4
4/18/09 11:53:00 AM Page N U C L I D E I
D E N T I F I C A T I O N R E P O R T Sample
Title:
1-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB IDENTIFIED NUCLIDES Nuclide Id Name Confidence Energy (keV)
CO-60 0.981 1173.22*
1332.49*
CS-137 0.971 661.65*
BI-211 0.596 351.10*
404.80 PB-212 0.709 87.20 89.80 238.63*
300.09 BI-214 0.638 609.31*
934.06 1764.49 Yield
(%)
100.00 100.00 85.12 12.20 4.10 6.30 1.75 44.60 3.41 46.30 3.21
- 15. 80 Activity (uCi/gram)
- 2. 67E-006 2.93E-006 2.26E-007
- 4. 32E-007 1.47E-007
- 1. 85E-007 Activity Uncertainty 9.86E-008.
1.06E-007 3.35E-008 1.42E-007 4.21E-008 5.31E-008
- = Energy line found in the spectrum.
@ = Energy line not used for Weighted Mean Activity Energy Tolerance :
1.000 keV Nuclide confidence index threshold.=
0.30 Errors quoted at 1.000 sigma
interference Corrected Activity Report 4/18/09 11:53:00 AM Page I NT E RF ER E NCE C O RRE C TED REP O RT.
Nuclide Nuclide IId Name Confidence CO-60 CS-137 BI-211 PB-212 BI-214 X
PB-214 0.981 0.971 0.596 0.709 0.638
- 0. 680 Wt mean Activity (uCi/gram) 2
- 79E-006 2.26E-007 4.32E-007
- 1. 47E-007
- 1. 85E-007 Wt mean Activity Uncertainty 7.22E-008 3.35E-008 1.42E-007 4.21E-008 5.31E-008 Total Activity 3.78E-006
? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.000 sigma U N I D E N T I F I E D P E A K S Peak Locate Performed on:
Peak Locate From Channel:
Peak Locate To Channel:
4/18/09 100 4096 11:52:59 AM Peak Energy No.
(key) 2 295.14 M = First peak in a
m = Other peak in a
F'= Fitted singlet Peak Size in Counts per Second 8.96E-003 multiplet region multiplet region Peak CPS
% Uncertainty 62.05 Errors quoted at 1.000 sigma
- -******-4*****~
GA MMA SPECTRUM ANALY SI S
OYSTER CREEK NUCLEAR GENERATING STATION CHEMISTRY DEPARTMENT Detector Name
- DET02 Report Generated On
- 4/19/09 9:24:15 AM Spectral Data File Name
\\2000061.CNF Sample Title Sample Description User ID Sample Type Sample Geometry Peak Locate Threshold Peak Locate Range (in channels)
.Peak Area Range (in channels)
Identification Energy Tolerance Sample Size C:\\PCNT2K\\CAMFILES\\ILSOLMDA 1-L Solid Releas Soil near CST; Lower, South of Pipe kg 20 1-L Marinelli 3.00 1 -
4096 100 -
4096 1.000 keV 807.00 grams Sample Taken On Acquisition Started Decay Time 4/18/09 5:00:48 AM 4/19/09
.8:10:51 AM 1.63E+003 Minutes Live Time Real Time Dead Time 4701.0 Seconds 4702.7 Seconds 0.04 %
Energy Calibration Used Done On Efficiency Calibration Used Done On 3/21/08 3/21/08 f. 0,e..
-721 Al/.jKk-~)Y~ \\
~
J I
(R~jjLiQjk~;~
'I
}
Background Subtract Report 4/19/09 9:24:15 AM Page 2
B A C KIG R 0 U N D S U B T R A C T R E P 0 R T Detector Name:
DET02 Sample
Title:
1-L Solid Releas Peak Analysis Performed on:
4/19/09 9:24:15 AM Peak Energy Subtracted No.
(keY)
Uncert.
2--
1 238.66 3.71E+001
'.11I 2
351.83 2.42E+001 3
401.85 2.19E+001
, 7 43E+
4 -583.17
"*2.43E+001 S
5 609.39 i-I 1.68E+001 6
661.66 2.77E+001 7
1173.56
\\JJ 5.31E+001 8
1332.91 4.86E+001 Original Orig. Area Area Uncert.
Ambient
Background
Backgr.
Uncert.
- 1. 42E+002
- 9. OOE+001
- 3. 67E+001
- 1. 01E+002
- 6. 12E+001
- 1. 32E+002
- 2. 52E+003 2.26E+003 37.12 24.23 21.94 24.29 16.83 27.66 53..07 48.63 Subtracted Area 1.42E+002 9.OOE+001 3.67E+001 1.01E+002 6.12E+001 1.32E+002
- 2.52E+003 2.26E+003 M = First peak in a multiplet region m = Other peak in F = Fitted singlet a multiplet region Errors quoted at 1.000 sigma
Nuclide MDA Report 4/19/09 9:24:15 AM Page 3
N U C L I D E M D A R E P 0 R T Detector Name:
DET02 Sample Geometry:
I-L Marinelli Sample
Title:
1-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB Nuclide Activity Name (uCi/gram)
CS-134
- 6. 42E-009
- 2. 12E-008
- 2. 42E-007
- 4. 73E-008
+
- 1. 72E-007 Energy (keY) 563.23 569.32 604.70 795.84 801.93 1365.15 661.65*
Yield
(%)
8.38 15.43 97.60 85.40 8.73 3.04 85.12 Line MDA (uCi/gram)
- 9. 87E-007
- 4. 65E-007
- 8. 74E-008
- 1. 42E-007
- 1. 32E-006
- 1. 65E-006
+ = Nuclide identified during the nuclide identification
- = Energy line found in the spectrum
> = MDA value not calculated
@ = Half-life too short to be able to perform the decay correction
interference Corrected Activity Report 4/19/09 9:24:15 AM Page
-*
- 4** **
N U C L I D E IDENTIFICATION REPORT Sample
Title:
I-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB IDENTIFIED NUCLIDES Nuclide Name Co CO-60 CS-137 BI-211 PB-212 BI-214 Id Energy nfidence (keY) 0.976 1173.22*
1332.49*
1.000 661.65*
0.556 351.10*
404.80 0.674 87.20 89.80 238.63*
300.09 0.660 609.31*
934.06 1764.49 Yield Activity
(%)
(uCi/gram) 100.00 100.00 85.12 12.20 4.10 6.30 1.75 44.60 3.41 46.30 3.21 15.80
- 4. 68E-006
- 4. 72E-006 1.72E-007
- 4. 56E-007
- 1.39E-007 1.36E-007 Activity Uncertainty 1.30E-007 1.39E-007 3.62E-008 1.23E-007 3.65E-008 3.75E-008
- = Energy line found in the spectrum.
@ = Energy line not used for Weighted Mean Activity Energy Tolerance :
1.000 keV Nuclide confidence index threshold =
0.30 Errors.quoted at 1.000 sigma
interference Corrected Activity Report 41191,09 9:24:15 AM Page IN***
INTERFERENCE CORRECTED REPORT Nuclide Nuclide Id Name Confidence CO-60 CS-137 BI-211 PB-212 BI-214 0.976 1.000 0.556 0.674 0.660 Wt mean Activity (uCi/gram) 4.70E-006
- 1. 72E-007
- 4. 56E-007
- 1. 39E-007 1.36E-007 Wt mean Activity Uncertainty
- 9. 48E-008 3.62E-008 1.23E-007
- 3. 65E-008 3.75E-008 Total Activity
- 5. 60E-006
?= nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@= nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at -1.000 sigma UNIDENTIFIED PEAKS Peak Locate Performed on:
Peak Locate From Channel:
Peak Locate To Channel:
4/19/09 100 4096 9:24:15 AM Peak Energy No.
(keV)
Peak Size in Counts per Second Peak CPS
% Uncertainty 3
401.85 583.17
- 7. 80E-003
,2.14E-002 59.85 24.15 M1 First peak in a m = Other peak in a
F = Fitted singlet multiplet region multiplet region Errors quoted at 1.000 sigma
GAMMA SPECTRUM PAN AL7Y SIS OYSTER CREEK NUCLEAR GENERATING STATION CHEMISTRY DEPARTMENT Detector Name
- DET01 Report Generated On Spectral Data File Name
\\2000063.CNF Sample Title Sample Description User ID Sample Type Sample Geometry Peak Locate Threshold Peak Locate Range (in channels)
Peak Area Range (in channels)
Identification Energy Tolerance 4/21/09 12:04:23 PM C:\\PCNT2K\\CAMFILES\\ILSOLMDA 1-L Solid Releas Soil from New Hole; Depth 1 kg 20 1-L Marinelli 3.00 1 -
100 -
1.000 4096 4096 keV Sample Size 872.00 grams Sample Taken On Acquisition Started Decay Time 4/21/09 11:25:22 AM 4/21/09 11:49:24 AM 2.40E+001 Minutes Live Time Real Time Dead Time 1197.0 Seconds 1197.5 Seconds 0.04 %
Energy Calibration Used Done On Efficiency Calibration Used Done On 1/ 8/09 1/ 8/09 7~U U
ii
.~-
-7/
/'
/
/
~
Vh~-/
7-)
I'
( ~'~JiI(-
//
,2\\
/7'
Background Subtract Report 4/21/09 12:04:23 PM Page B A C K G R O U N D S U B T R A C T R E P O R T Detector Name:
DET01 Sample
Title:
1-L Solid Releas Peak Analysis Performed on:
4/21/09 12:04:23 PM Peak Energy Original Orig. Area Ambient Backgr.
Subtracted Subtracted No.
(keV)
Area Uncert.
Background
Uncert.
Area Uncert.
2-1 238.54 2.30E+001 10.40 2.30E+001 1.04E+001 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
Nuclide MDA Report 4/21/09 12:04:24 PM Page 3
NUCLIDE MDA REPORT Detector Name:
Sample Geometry:
Sample
Title:
DET01 IL Marinelli I-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB Nuclide Activity Name (uCi/gram)
CS-134 3.64E-007 8.35E-008 1.53E-007 6.66E-009 2.63E-007 1.01E-007 CS-137
- 5. OOE-009 Energy (keY) 563.23 569.32 604.70 795.84 801.93 1365.15 661.65 Yield
(%)
8.38 15.43 97.60 85.40 8.73 3.04 85.12 Line MDA (uCi/gram)
- 1. 03E-006
- 6. 73E-007 7.20E-008
+ = Nuclide identified during the nuclide identification
- = Energy line found in the spectrum
> = MDA value not calculated
@ = Half-life too short to be able to perform the decay correction
Interference Corrected Activity Report 4/21/09 12:04:24 PM Page N U C L I D E I
D E N T I F I C A T I O N R E P O R T
- +***********************
Sample
Title:
1-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB IDENTIFIED NUCLIDES Nuclide Id Name Confidence PB-212 0.709 Energy (keV) 87.20 89.80 238.63*
300.09 Yield
(%)
6.30 1.75 44.60 3.41 Activity (uCi/gram)
- 1. 19E-007 Activity Uncertainty 5.40E-008
- = Energy line found in the spectrum.
@ = Energy line not used for Weighted Mean Activity Energy Tolerance :
1.000 keV Nuclide confidence index threshold =
0.30 Errors quoted at 1.000 sigma
interference Corrected Activity Report 4/21/09 12:04:24 PM Page 9*9 INTERFERENCE CORRECTED REPORT Nuclide Nuclide Id Name Confidence Wt mean Activity (uCi/gram)
- 1. 19E-007 Wt mean Activity Uncertainty 5.40E-008 PB-212 0.709 Total Activity
- 1. 19E-007
? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.000 sigma U N I D E N T I F I E D P E A K S Peak Locate Performed on:
Peak Locate From Channel:
Peak Locate To Channel:
4/21/09 100 4096 12:04:23 PM Peak Energy No.
(keY)
Peak Size in Counts per Second Peak CPS
% Uncertainty All peaks were identified.
M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
OYSTER CREEK NUCLEAR GENERATING STATION CHEMISTRY DEPARTMENT.
Detector Name
- DET02 Report Generated On Spectral Data File Name
\\2000074.CNF Sample Title Sample Description User ID Sample Type Sample Geometry Peak Locate Threshold Peak Locate Range (in channels)
Peak Area Range (in channels)
Identification Energy Tolerance 4/25/09 1:34:31 AM C:\\PCNT2K\\CAMFILES\\1LSOLMDA 1-L Solid Releas N side of pump house soil nc226 20 1-L Marinelli 3.00 1-100 -
1.000 4096 4096 keV Sample Size 1742.00 grams Sample Taken On Acquisition Started Decay Time 4/24/09 7:00:00 PM 4/25/09 1:21:23 AM 3.81E+002 Minutes Live Time Real Time Dead Time 1087.0 Seconds 1087.2 Seconds 0.02 %
Energy Calibration Used-Done On Efficiency Calibration Used Done On 3/21/08 3/21/08 U
e C
~O
/
/1/27~&Q I; 0a.1,)
J~, ?~f f
E 5 7
/ j -
- 7--
Background Subtract Report 4/25/09 1:34:32 AM Page B A C K G R O U N D S U B T R A C T R E P O R T Detector Name:
DET02 Sample
Title:
I-L Solid Releas Peak Analysis Performed on:
4/25/09 1:34:31 AN Peak' Energy Subtracted No.
(keV)
Uncert.
77?-.Zi2-1 238.56 1.78E+001 2
351.90 1.35E+001 3
583.36 6.91E+000
(-*
4 661.81 9.60E+000 5
1332.90 5.88E+000 6
1461.80 40*
5.19E+000 Original Orig. Area Ambient Backgr.
Area Uncert.
Background
Uncert.
- 8. 46E+001 4.24E+001
- 2. 34E+001
- 8. 72E+001
- 3. 04E+001
- 2. 37E+001 17.76 13.46 6.91 9.60
.5.88 5.19 Subtracted Area 8.46E+001 4.24E+001 2.34E+001 8.72E+001 3.04E+001 2.37E+001
}-?J
?eqO 7 AG/ onI M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
N,,ic -I --Lde MDA Reoort 4/25,'09 1:34:32 A;aM Page N U CL IDE M DA RE PO0R T Detector Name:
Sample Geometry:
Sample
Title:
DET02 I-L Marinelli i-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB Activity (uCi/gram)
Nuclide Name CS-134 1.27E-007 1.30E-007 5.12E-009 1.33E-008
- 2. 02E-008
- 2. 81E-007
+
CS-137 2.28E-007 Energy (keV) 563.23 569.32 604.70 795.84 801.93 1365.15 661.65*
Yield
(%)
8.38 15.43 97.60 85.40 8.73 3.04 85.12 Line MDA (uCi/gram) 5.37E-007
- 3. 08E-007
- 2. 95E-008
- 6. 55E-008
+ = Nuclide identified during the nuclide identification Energy line found in the spectrum
>= MDA value not calculated
= Half-life too short to be able to perform the decay correction
interference Corrected Activity Report 4/25/09 1:34:32 AM Page N U C L I D E I D E N T I F I C A T I O N R E P O R T Sample
Title:
1-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB IDENTIFIED NUCLIDES Nuclide Id Name Confidence Energy (keY)
K-40 0.855 1460.81*
CS-137 0.996 661.65*
BI-211 0.544 351.10*
404.80 PB-212 0.674 87.20 89.80 238.63*
300.09 Yield 10.67 85.12 12.20 4.10 6.30 1.75 44.60 3.41 Activity (uCi/gram)
- 1. OIE-006 2.28E-007 4.30E-007
'1. 66E-007 Activity Uncertainty 2.22E-007
- 2. 55E-008 1.37E-007 3.50E-008
- = Energy line found in the spectrum.
@ = Energy line not used for Weighted Mean Activity Energy Tolerance :
1.000 keV Nuclide confidence index threshold =
0.30 Errors quoted at 1.000 sigma
interference Corrected Activity Report 4125/09 1:34:32 AM Page 5
S I N T E R F E R E N C E C O R R E C T E D R E P O R T Nuclide Nuclide Id Name Confidence Wt mean Activity (uCi/gram)
I. 01E-006 2.28E-007 4.30E-007 1.66E-007 Wt mean Activity Uncertainty 2.22E-007 2.55E-008 1.37E-007 3.50E-008 K-40 CS-137 BI-211 PB-212 0.855 0.996 0.544 0.674 Total Activity
- 1. 83E-006
? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.000 sigma U N I D E N T I F I E D P E A K S Peak Locate Performed on:
Peak Locate From Channel:
Peak Locate To Channel:
4/25/09 100 4096 1:34:31 AM Peak Energy No.
(keV)
Peak Size in Counts per Second Peak CPS
% Uncertainty 3
5 583.36 2.15E-002 1332.90
-*]a z
- 2. 80E-002 First peak in a multiplet region Other peak in a multiplet region Fitted singlet 29.58 19.32
/Vo/
M m
F Errors quoted at 1.000 sigma
A*.*
+
- GAMMA SPECTRUM ANALYSIS OYSTER CREEK NUCLEAR GENERATING STATION CHEMISTRY DEPARTMENT Detector Name
- DET02 Report Generated On Spectral Data File Name
\\2000075.CNF Sample Title Sample Description User ID Sample Type Sample Geometry Peak Locate Threshold Peak Locate Range (in channels)
Peak Area Range (in channels)
Identification Energy Tolerance 4/25/09 2:18:15 AM C:\\PCNT2K\\CAMFILES\\ILSOLMDA 1-L Solid Releas soil n of cst 1i nc226 20 I-L Marinelli 3.00 1 -
4096 100,-
4096 1.000 keV Sample Size 1613.00 grams Sample Taken On Acquisition Started Decay Time 4/25/09 2:00:05 AM 4/25/09 2:05:07 AM 5.04E+000 Minutes Live Time Real Time Dead Time 1086.0 Seconds 1086.2 Seconds 0.02 %
Energy Calibration Used Done On Efficiency Calibration Used Done On 3/21/08 3/21/08
- ~9l)1eL4)
I j-C- 011-0<
LlJ Q
57
Background Subtract Report 4/25/09 2-18:15 A-M Page B A C K G R O U N D S U B T R A C T R E.P 0 R T Detector Name:
DET02 Sample
Title:
l-L Solid Releas Peak Analysis Performed on:
4/25/09 2:18:15 AM Peak Energy Subtracted No.
(keV)
Uncert.
-7ýZ2 1
238.51 1.87E+001 2
295.18 1.21E+001
-21 3
352.01 1.20E+001 4
583.11
'1
- '9.61E+000 5
609.11 8.03E+000 6
661.83 9.55E+000 7
1332.97 4.91E+000 8
1461.22 8.57E+000 Original Orig. Area Ambient Area Uncert.
Background
Backgr.
Uncert.
- 1. 17E+002 4.47E+001
- 8. 48E+001 4.76E+001
- 3. 90E+001
- 5. 89E+001
- 1. 85E+001
- 5. 93E+001 18.74 12.14 12.04 9.61 8.03 9.55 4.91 8.57 Subtracted Area 1.17E+002 4.47E+001 8.48E+001 4.76E+001 3.90E+001 5.89E+001 1.85E+OOl 00.r 1h/
5.93E+001 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
lluciide MDA, Report p4/25/09 2:18:15 AM Page N U C T
i D E M D A R E P 0 R T Detector Name:
Sample Geometry:
Sample
Title:
Nuclide Library DET02 I-L Marinelli 1-L Solid Releas Used: C:\\GENIE2K\\CANFILES\\AnSolMDA.NLB Activity (uCi/gram!
Nuclide Name CS-134
- 1. 95E-008 9.60E-009 6.29E-009 1.34E-008 2.18E-008
- 0. 00E+000
+
CS-137 Energy (keV) 563.23 569.32 604.70 795.84 801.93 1365.15 661. 65*
Yield
(%)
8.38 15.43 97.60 85.40 8.73 3.04 85.12 Line MDA (uCi/gram) 6A.6E-007
- 2. 89E-007
- 5. 08E-008
- 9. 08E-008
- 4. 61E-007
- 1. 66E-007
+
Nuclide identified during the nuclide identification Energy line found in the spectrum MDA value not calculated Half-life too short to be able to perform the decay correction
Interterence Corrected Activity Report 4
4/25,09 2:18:15 AM
- Page N U C L I D E I
D E N T I F I C A T I O N R E P O R T Sample
Title:
I-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB IDENTIFIED NUCLIDES Nuclide Id Energy Name Confidence (keY)
K-40 0.973 1460.81*
CS-137 0.995 661.65*
PB-212 0.672 87.20 89.80 238.63*
300.09 BI-214 0.656 609.31*
934.06 1764.49 PB-214 0.676 87.20 89.80 241-.98 295.21*
351.92*
Yield
(%)
10.67 85.12 6.30 1.75 44.60 3.41 46.30 3.21 15.80 3.70 1.03 7.49 19.20 37.20 Activity (uCi/gram)
- 2. 72E-006
- 1. 66E-007 2.48E-007
- 1. 87E-007
- 2. 65E-007
- 3. 05E-007 Activity Uncertainty 3.99E-007 2.72E-008 4.01E-008 3.88E-008 7.22E-008 4.37E-008
= Energy line found in the spectrum.
@= Energy line not used for Weighted Mean Activity Energy Tolerance 1.000 keV Nuclide confidence index threshold =
0.30 Errors quoted at 1.000 sigma
interference Corrected Activizy Report 4/25/09 2:13:15 AM Page IN*TERRF ERENCE CORRECTED
-REPORT Nuclide Nuclide id Name Confidence K-40 CS-137 x
BI-211 PB-212 BI-214 PB-214 0.973 0.995 0.522
- 0. 672 0.656 0.676 Wt mean Activity (uCi/gram) 2.72E-006
- 1. 66E-007 2.48E-007
- 1. 87E-007 2.94E-007 Wt mean Activity Uncertainty 3.99E-007 2.72E-008 4.01E-008 3.88E-008 3.74E-008 Total Activity
- 3. 62E-006
?
= nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.000 sigma U N I D E N T I F I E D Peak Locate Performed on:
Peak Locate From Channel:
Peak Locate To Channel:
P E A K S 4/25/09 100 4096 2:18:15 AM Peak Energy No.
(keV)
Peak Size in Counts per Second Peak CPS
% Uncertainty 1-d,7w
<CIIý4 -
4 7
583 11l~
4.39E-002 13397-2 V
1.70E-002 First peak in a multiplet region Other peak in a multiplet region Fitted singlet 20.16 26.57 _A)O0 0(1* /%Q4 N
m F
Errors quoted at 1.000 sigma V>
OYSTER CREEK NUCLEAR GENERATING STATION CHEMISTRY DEPARTMENT Detector Name DET01 Report Generated On Spectral Data File Name
\\2000076.CNF Sample Title Sample Description User ID Sample Type Sample Geometry Peak Locate Threshold Peak Locate Range (in channels)
Peak Area Range (in channels)
Identification Energy Tolerance
- 4/25/09 2:30:59 AM C:\\PCNT2K\\CAMFILES\\ILSOLMDA /
- l-L Solid Releas soil n of cst 2' nc226 20 1-L Marinelli 3.00 1 -
100 -
1.000 4096 4096 keV Sample Size 1617.00 grams Sample Taken On Acquisition Started Decay Time 4/25/09 2:04:47 AM 4/25/09 2:09:49 AM 5.04E+000 Minutes Live Time Real Time Dead Time 1568.0 Seconds 1568.8 Seconds 0.05 %
Energy Calibration Used Done On Efficiency Calibration Used Done On 1/8/09 1/8/09
¢ /
/ev F
(
/ ~
y2/
i' 7'
/A
/ 2 ~ )~j1LC~I~ ( Q~(~2(y~;I
"',/-7
Background Subtract Report 4/25/09 2:30:59 AM Page B A C K G R O U N D S U B T R A C T R E P O R T Detector Name:
DET01 Sample
Title:
1-L Solid Releas Peak Analysis Performed on:
4/25/09 2:30:59 AM 3;..1 3
t-7O
(,'-Iao Peak Energy Subtracted No.
(keY)
Uncert.
M 1
238.51 1.24E+001 m
2 241.54 8.26E+000 3
351.69 1.28E+001 4
582.82 8.64E+000 5
609.01 9.08E+000 6
661.32 9.66E+000 7
1172.81 8.80E+000 8
1332.64 8..37E+000 9
1460.69 8.26E+000 Original Orig. Area Area Uncert.
Ambient
Background
Backgr.
Uncert.
1.36E+002
- 4. 61E+001 S. 56E+001 4.45E+001
- 4. 50E+001
- 3. 66E+001
- 5. 25E+001
- 5. 80E+001
- 5. 98E+001 12.42 8.26 12.83 8..64 9.08 9.66 8.80 8.37 8.26 Subtracted Area 1.36E+002 4.61E+001 5.56E+001 4.45E+001 4.50E+001 3.66E+001 5.25E+001 5.80E+001 5.98E+001 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
Nuclide MIDA Report 4/25/09 2:31:00 AM Page N U C L IDE M DA R E POR T
.5 Detector Name:
DET01 Sample Geometry:
1-L Marinelli Sample
Title:
1-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB Nuclide Activity Name (uCi/gram)
CS-134
- 7. 83E-008 4.04E-009 5.35E-009
- 2. 16E-008 4.91E-008
- 1. 19E-006
+
CS-137 1.13E-007 Energy (keY) 563.23 569.32 604."70 795.84 801.93 1365.15 661.65*
Yield
(%)
8.38 15.43 97.60 85.40 8.73 3.04 85.12 Line MDA (uCi/gram)
- 9. 37E-007 4.39E-007
- 6. 06E-008
- 1. 03E-007
- 8. 09E-007 2.35E-006
+ = Nuclide identified during the nuclide identification
- = Energy line found in the spectrum
= MDA value not calculated
@ = Half-life too short to be able to perform the decay correction
interference Corrected Activity Report 4/25/09 2:31:00 AM P-:age 4
N U C LI D E I D E N T I F I C A T I O N R E P O R T Sample
Title:
l-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB IDENTIFIED NUCLIDES Nuclide Id Name Confidence Energy (keV)
K-40 0.998 1460.81*
CO-60 0.985 1173.22*
1332 49*
CS-137 0.982 661.65*
PB-212 0.708 87.20
- 89. 80 238.63*
300.09 BI-214 0.652 609.31*
934. 06 1764.49 PB-214 0.418 87.20 89.80 241.98*
295.21 351.92*
Yield
(%)
10.67 100.00 100.00 85.12 6.30 1.75
- 44. 60 3.41 46.30 3.21 15.80 3.70 1.03 7.49 19.20 37.20 Activity (uCi/gram)
- 3. 01E-006 2.32E-007
- 2. 87E-007
- 2. 36E-007
- 5. 93E-007
- 2. OBE-007 Activity Uncertainty 4.22E-007 3.92E-008 4.19E-008 2.99E-008 2.72E-008 4.79E-008 1.07E-007 4.81E-008
- = Energy line found in the spectrum.
@ = Energy line not used for Weighted Mean Activity Energy Tolerance :
1.000 keV Nuclide confidence index threshold =
0.30 Errors quoted at 1.000 sigma
interference Corrected Activity Report 4 1, 2ý 5 / a 9
- 2) : 3 1 : 0 0 AM Page
.4 ******
+ * ***
- * *.4.4.4.4...4*
.4 INTERFERENCE CORRECTED REPORT
-4.4.4.4*
.4.4.4 ****.4**
- .4 * **
.4.4.4 * *4*
- .4 *
.4.4.4* *.4 * *.4.4 *
, * * *.4 *
- Nuclide Name Nuclide Id Confidence Wt mean Activity (uCi/gram)
B1 7 211 PB-212 BI-214 PB-214 0.998
- 0. 985 0.982 0.578 0.708
- 0. 652 0.418
- 3. 01E-006
- 2. 58E-007 1.13E-007
- 2. 90E-007 2.36E-007
- 2. 72E-007 Wt mean Activity Uncertainty 4.22E-007 2.86E-008 2.99E-008 2.72E-008 4.79E-008 4.38E-008 Total Activity
- 4. 18E-006
= nuclide is part of an undetermined solution X
= nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.000 sigma U N I D E N T I F I E D P E A K S 2:0:59**
2:30:59 AM Peak LocatePerformed on:
Peak Locate From Channel:
Peak Locate To Channel:
4/25/09 100 4096 Peak Energy No.
(keY)
Peak Size in Counts per Second Peak CPS
% Uncertainty' 582.82
- 2. 84E-002 19.41 M = First peak in a
m = Other peak in a
F = Fitted singlet multiplet region multiplet region Errors quoted at 1.000 sigma
GAMMA SPECTRUM RN LYM A NA LY SI S
OYSTER CREEK NUCLEAR GENERATING STATION CHEMISTRY DEPARTMENT Detector Name
- DET01 Report Generated On
- 4/25/09 4:07:58 AM Spectral Data File Name
\\2000077.CNF Sample Title Sample Description User ID' Sample Type Sample Geometry Peak Locate Threshold Peak Locate Range (in channels)
Peak Area Range (in channels)
Identification Energy Tolerance Sample Size Sample Taken On Acquisition Started Decay Time C:\\PCNT2K\\CAMFILES\\ILSOLMDA 1-L Solid Releas soil n of cst 3'
- -nc226 20 1-L Marinelli 3.00 1 -
4096 100 -
4096 1.000 keV 1547.00 grams 4/25/09 3:45:47 AM 4/25/09 3:50:49 AM 5.04E+000 Minutes Live Time Real Time Dead Time 1327.0 Seconds 1327.7 Seconds
.0.05 Energy Calibration Used Done On Efficiency Calibration Used Done On 1/8/09
- 1/8/09 1--/)
1%~r~I 2 1/
.i )!C~
Background Subtract Report 4/25/09 4:07:58 AM Page B A C K G R O U N D S U B T R A C T R E P O R T Detector Name:
DET01 Sample
Title:
1-L Solid Releas Peak Analysis Performed on:
4/25/09 4:07:58 AM Peak Energy Subtracted No.
(keY)
Uncert.
Z--
1 238.65
- 1. 60E+001 2
351.65
- 1. 01E+001 3
582.61
- 7. 15E+000 3;.Z14 4
609.11 7 67E+000 5
661.01
- 7. 07E+000 6
1172.79
- 8. 92E+000 7
1332.21 7.89E+000 Original Orig. Area Area Uncert.
Ambient
Background
Backgr.
Uncert.
- 7. 99E+001
- 3. 61E+001 3.19E+001
- 2. 77E+001
- 1. 83E+001
- 6. 73E+001
- 5. 25E+001 15.97 10.11 7.15 7.67 7.07 8.92 7.89 Subtracted Area 7.99E+001 3.61E+001 3.19E+001
- 2. 77E+001 1.83E+001 6.73E+001 5.25E+001 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
Nuclide MIDA Report 4/25/09 4:07:58 AM Page N U C L I D E M D A R E P 0 R T Detector Name:
Sample Geometry:
Sample
Title:
Nuclide Library Used:
DETO0 1-L Marinelli 1-L Solid Releas C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB Activity (uCi/gram]
Nuclide Name CS-134 8.59E-009
- 2. 42E-008 1.70E-008 1.19E-008
- 3. 21E-008
- 2. 06E-007
+
- 6. 98E-008 Energy (keV) 563.23 569.32 604.70 795.84 801.93 1365.15 661.65*
Yield
(%)
8.38 15.43 97.60 85.40 8.73
.3.04 85.12 Line MDA (uCi/gram)
- 7. 44E-007
- 3. 42E-007
- 8. 85E-008
- 9. 63E-008
- 9. 99E-007
- 1. 91E-006
- 1. lOE-007 Nuclide MDA (uCi/gram) 8.85E-008 1.IOE-007
+ = Nuclide identified during the nuclide identification
- = Energy line found in the spectrum
> = MDA value not calculated
@ = Half-life too short to be able to perform the decay correction
interference Corrected Activity Report 4
4/25/09 4:07:58 AM Page N U C L I D E ID E N T I F I C A T I 0 N R E P O R T Sample
Title:
I-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB IDENTIFIED NUCLIDES Nuclide Id Energy Name Confidence (keV)
CO-60 0.979 1173.22*
1332.49*
CS-137 0.937 661.65*
BI-211 0.583 351.10*
404.80 PB-212 0.709 87.20 89.80 238.63*
300.09 BI-214 0.657 609.31*
934.06 1764.49 Yield Activity
(%)
(uCi/gram) 100.00 100.00 85.12 12.20 4.10 6.30 1.75 44.60 3.41 46.30 3.21 15.80
- 3. 68E-007 3.21E-007 6.98E-008
- 5. 07E-007 2.11E-007 1.79E-007 Activity Uncertainty 4.92E-008 4.87E-008 2.70E-008 1'.43E-007 4.24E-008 4.98E-008
- = Energy line found in the spectrum.
@ = Energy line not used for Weighted Mean Activity Energy Tolerance :
1.000 keV Nuclide confidence index threshold =
0.30 Errors quoted at 1.000 sigma
interference Corrected Activity Report E5 4/25/09 4:07:58 AM Page I N T E R FE R E N C E C O R R E C T E D R E P O R T Nuclide Nuclide Id Name Confidence CO-60 CS-137 BI-211 PB-212 BI-214 0.979 0.937 0.583 0.709 0.657 Wt mean Activity (uCi/gram) 3.44E-007
- 6. 98E-008
- 5. 07E-007
- 2. llE-007 1.79E-007 Wt mean Activity Uncertainty 3.46E-008 2.70E-008 1.43E-007 4.24E-008 4.98E-008 Total Activity 1.31E-006
? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity
-Errors quoted at 1.000 sigma SU N I D E N T I F I E D P E A K S Peak Locate Performed on:
Peak Locate From Channel:
Peak Locate To Channel:
4/25/09 100 4096 4:07:58 AM Peak Energy No.
(keV)
Peak Size in Counts per Second Peak CPS
% Uncertainty 582.61 2.40E-002
'22.44 M = First peak in a
m = Other peak in a
F = Fitted singlet multiplet region multiplet region Errors quoted at 1.000 sigma
G A MMA S P E C TR U M A NA LY S IS OYSTER CREEK NUCLEAR GENERATING STATION CHEMISTRY DEPARTMENT Detector Name
- DET02.
Report Generated On Spectral Data File Name
\\2000078.CNF Sample Title Sample Description User ID Sample Type Sample Geometry Peak Locate Threshold Peak Locate Range (in channels)
Peak Area Range (in channels)
Identification Energy.Tolerance 4/25/09 4:06:07 AM C:\\PCNT2K\\CAMFILES\\ILSOLMDA I-L Solid Releas soil n of cst 4' nc226 20 I-L Marinelli 3.00 1 -
100
- l. OOQ 4096 4096 keY Sample Size 1420.00 grams Sample Taken On Acquisition Started Decay Time 4/25/09 3:49:34 AM 4/25/09 3:54:36 AM 5.04E+000 Minutes Live Time Real Time Dead Time 989.0 Seconds 989.2 Seconds 0.02 %
Energy Calibration Used Done On Efficiency Calibration Used Done On 3/21/08 3/21/08
/
'~5/~>~
/
4 ýý / /
~*9
//
/
i;~-lI U-i
Sackground Subtract Report 4/'2 5/09 4 -.0 6:-07 AM Page B AC KG R OU ND S U B TRA CT R E PO RT Detector Name:
DET02 Sample
Title:
1-L Solid Releas Peak Analysis Performed on:
4/25/09 4:06:07 AM Peak Energy Subtracted No.
(keV)
Uncert.
1 238.66 1.67E+001 z/
2 351.81 9.33E+000 3
609.44 8.07E+000
/4 1173.52 6.55E+000 5
1461.61 7.04E+O00 Original Orig. Area Ambient Area Uncert.
Background
Backgr.
Uncert.
6.62E+001
- 5. 20E+001
- 2. 90E+001 3.59E+001
- 4. 20E+001 16.69 9.33 8.07 6.55 7.04 Subtracted Area 6.62E+001 5.20E+001 2.90E+001 3.59E+001
/
1 4.20E+00j~1t M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
Nuclide MIDA Report 4 /25/09 4:06:07 AM Page ND N U C L iDE M DA R E POR T
Detector Name:
DET02 Sample Geometry:
l-L Marinelli Sample
Title:
1-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolDA.NLB Nuclide Activity Name (uCi/gram)
CS-134 1.75E-008
- 5. 07E-008 7.53E-009 3.04E-008 1.13E-008
- 0. 0OE+000 CS-137
- 1. 20E-007 Energy (keV) 563.23 569.32 604.70 795.84 801.93 1365.15 661.65 Yield
(%)
8.38 15.43 97.60 85.40 8.73 3.04 85.12
-Line MDA (uCi/gram) 7.24E-007 2.94E-007 6.02E-008
- 1. 02E-007
+ = Nuclide identified during the nuclide identification
- = Energy line found in the spectrum
> = MDA value not calculated
@ = Half-life too short to be able to perform the decay correction
7n terference Corrected Activity Report 4i25/09 4:06:07 AM Page interference Corrected Activity Report 4,25/09 4:06:07AI~
Page 4
~ * * * * * * * * * * *,4 * * * * -4
- 4 * * -k * * * * * * * *
- k ***********
- * ~ *
- 4 *
-4 NUCLIDE IDENTIFICATION REPORT Sample
Title:
1-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB IDENTIFIED NUCLIDES Nuclide Id Name Confidence Energy (keV)
K-40 0.902 1460.81*
BI-211 0.559 351.10" 404.80 PB-212 0.674 87.20 89.80 238.63*
300.09 BI-214 0.659 609.31*
934.06 1764.49 Yield
(%)
10.67 12.20 4.10 6.30 1.75 44.60 3.41 46.30 3.21
- 15. 80 Activity (uCi/gram) 2.41E-006
- 7. 11E-007 1.75E-007 1.74E-007 Activity Uncertainty 4.07E-007 1.28E-007 4.43E-008 4.85E-008
- = Energy line found in the spectrum.
@ = Energy line not used for Weighted Mean Activity Energy Tolerance :
1.000 keV Nuclide confidence index threshold =
0.30 Errors quoted at 1.000 sigma
interference Corrected Activity Report 4/25/09 4:06:07 AM Page IN T E R F E R E N C E C O R R E C T E D R E P O R T Nuclide Nuclide Id Name Confidence Wt mean Activity (uCi/gram)
- 2. 41E-006 7.11E-007 I 75E-007 1.74E-007 Wt mean Activity Uncertainty 4.07E-007 1.28E-007 4.43E-008 4.85E-008 K-40 BI-211 PB-212 BI-214 0.902 0.559 0.674 0.659 Total, Activity 3.47E-006
? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.000 sigma W* ***
W*W U N I D E N T I F I E D PEAKS Peak Locate Performed on:
Peak Locate From Channel:
Peak Locate To Channel:
4/25/09 100 4096 4:06:07 AM Peak Energy No.
(keV) 4 1173.52 Peak Size in Counts per Second 3.63E-002 Peak CPS
% Uncertainty 1-8.24 MýO/or'1 lpeczk-M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
GAMMA SPECTRUM A
S A N A L Y S I S OYSTER CREEK NUCLEAR GENERATING STATION CHEMISTRY DEPARTMENT Detector Name DET02 Report Generated On Spectral Data File Name
\\2000079.CNF Sample Title Sample Description User ID Sample Type Sample Geometry Peak Locate Threshold Peak Locate Range (in channels)
Peak Area Range (in channels)
Identification Energy Tolerance Sample Size Sample Taken On Acquisition Started Decay Time Live Time Real Time Dead Time 4/25/09 4:36:37 AM C:\\PCNT2K\\CAMFILES\\ILSOLMDA 1-L Solid Releas soil n of cst 5' nc225 20 1-L Marinelli 3.00 1 -
4096 100 -
4096 1.000 keV 1550.00 grams 4/25/09 4:.24:24 AM 4/25/09 4:29:26 AM 5.04E+000 Minutes 730.0 Seconds 730.1 Seconds 0.02 %
Energy Calibration Used Done On Efficiency Calibration Used Done On 3/21/08 3/21/08 V,-,
r I
/
7)
Background Subtract Report 4/25/09 4:36:38 AM Page BACK G R 0 UN D SUBTRACT RE PORT
- 9
- -gWg 9
9***
4*
9*************-4*************************
Detector Name:
DET02 Sample
Title:
I-L Solid Releas Peak Analysis Performed on:
4/25/09 4:36:37 AM Peak Energy Subtracted No.
(keY)
Uncert.
1 238.61 1.29E+001 2
351.62 1.15E+001 3
583.33
- 8. 19E+000
- /4 4
609.24 6.67E+000 5
661.51 k.-*'
6.57E+000 All 6
911.24
- 4. 32E+000 7
1461.60 i
6.27E+000 Original Orig. Area Area Uncert.
Ambient
Background
Backgr.
Uncert.
- 4. 53E+001 4.30E+001
- 1. 81E+001
- 2. 63E+001 2.78E+001
- 1. 04E+001
- 3. 69E+001 12.93 11.47 8.19 6.67 6.57 4.32 6.27 Subtracted Area 4.53E+001 4.30E+001 1.81E+001 2.63E+001 2.78E+001 1.04E+001 3.69E+001 M = First peak in a multiplet region m = Other peak in F = Fitted singlet a multiplet region Errors quoted at 1.000 sigma
-Nuclide MDA Report 4/25/09 4:36:38 AMt Page NUCL7DE MDA REPORT Detector Name:.
Sample Geometry:
'Sample
Title:
Nuclide Library DET02 l-L Marinelli 1-L Solid Releas Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB Nuclide Activity Name (uCi/gram)
CS-134 5.95E-008 1.32E-007
- 8. 18E-009 1.94E-008 2.57E-007 7.05E-007
+
CS-137 1.21E-007 Energy (keV) 563.23 569.32 604.70 795.84 801.93 1365.15 661. 65*
Yield
(%)
8.38 15.43 97.60 85.40 8.73 3.04 85.12 Line.MDA (uCi/gram) 7.20E-007 5.15E-007 7.05E-008 1.31E-007
- 8. 82E-007 3.31E-006
+ = Nuclide identified during the nuclide identification
- = Energy line found in the spectrum
> = MDA value not calculated
@ = Half-life too short to be able. to perform the decay correction
)
Interference Corrected Activity Report 4
4/25/09 4:36:38 ATM Page N U C L I D E 7 D E N T i F I C A T IO N
R E P O R T Sample
Title:
l-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB IDENTIFIED NUCLIDES Nuclide Id Name Confidence Energy (keV)
K-40 0.906 1460.81*
CS-137 0.997 661.65*
BI-211 0.585 351.10*
404.80 PB-212 0.674 87.20
- 89. 80 238.63*
300.09 BI-214 0.660 609.31*
934.06 1764. 49 Yield
(%)
10.67 85.12 12.20 4.10 6.30 1.75 44.60 3.41 46.30 3.21 15.80 Activity (uCi/gram) 2.62E-006 1.21E-007 7.29E-007 1.49E-007 1.96E-007 Activity Uncertainty 4.50E-007 2.88E-008 1.95E-007 4.26E-008 4.98E-008
- = Energy line found in the spectrum.
@ = Energy line not used for Weighted Mean Activity Energy Tolerance :
1.000 keV Nuclide confidence index threshold =
0.30 Errors quoted at 1.000 sigma
interference Corrected Activity Report 4/25/09 4:36:38 AM Page I N T E R F E R E N C E C O R R EC T E D R E P O R T
)
Nuclide Nuclide Id
- Name, Confidence K-40 CS-137 BI-211 PB-212 BI-214 0.906 0.997 0.585 0.674 0.660 Wt mean Activity (uCi/gram) 2.62E-006 1.21E-007 7.29E-007
- 1. 49E- 007
- 1. 96E-007 Wt mean Activity Uncertainty 4.50E-007 2.88E-008 1.95E-007 4.26E-008 4.98E-008 Total Activity
- 3. 82E-006
= nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.000 sigma UNIDENTIFIED PEAKS Peak Locate Performed on:
Peak Locate From Channel:
Peak Locate To Channel:
4/25/09 100 4096 4:36:37 AM Peak Energy No.
(keV) j 583.33 6
911.24 M = First peak in a
m = Other peak in a
F = Fitted singlet Peak Size in Counts per Second 2.48E-002 1.42E-002 multiplet region multiplet region Peak CPS
% Uncertainty 45.25 41.68 Errors quoted at 1.000 sigma
I G A MMA SPECTRUM A NA LY S IS OYSTER CREEK NUCLEAR GENERATING STATION CHEMISTRY DEPARTMENT Detector Name
- DET02 Report Generated On 4/25/09 5:35:14 PM Spectral Data File Name Sample Title Sample Description User ID Sample Type Sample Geometry Peak Locate Threshold Peak Locate Range (in channels)
Peak Area Range (in channels)
Identification Energy Tolerance Sample Size Sample Taken On Acquisition Started Decay Time Live Time Real Time Dead Time C: \\PCNT2K\\CAMFILES\\1LLIQMAR\\700909.CNF 1-L Liq. Mar'lli Soil North Pump House 3' n4283
- 7 I-L Marinelli 3.00 1 -
4096 100 -
4096 1.000 keV 2130.67 grams 4/25/09 5:05:00 PM 4/25/09 5:18:33 PM 1.36E+001 Minutes 1000.0 Seconds 1000.2 Seconds 0.02 %
Energy Calibration Used Done On Efficiency Calibration Used Done'On 3/21/08 3/21/08
/
r
/" ý,rt i(
I-
/ tI(-/7i~
Background Subtract Report 4/25/09 5:35:15 PM Page 2
B A C K G R O U N D S U B T R A C T R E P 0 R T
- W.*
- j*********
- W*W***
- **W*W*
- W*
W*****:*******
- W****
Detector Name:
DET02 Sample
Title:
I-L Liq. Mar'lli Peak Analysis Performed on:
4/25/09 5:35:14 PM
,A~c Peak Energy Subtracted No.
(keY)
Uncert.
1 238.41 2.01E+001 2
249.71 1.34E+001 3
294. 75 1.27E+001 4
351.72 1.31E+001 5
609.16 8.34E+000 6
911.16 5.23E+000 7
1461.18 6.40E+000 M = First peak Original Orig. Area Area Uncert.
6. 63E+001 4.21E+001
- 4. 88E+001
- 5. 76E+001
- 5. 10E+001
- 1. 44E+001
- 3. 76E+001 20.14 13.41 12.73 13.14 8.34 5.23 6.40 Ambient Backgr.
Background
Uncert.
Subtracted Area 6.63E+001 4.21E+001 4.88E+001 5.76E+001 5.10E+001 1.44E+001 3.76E+001 in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
interference Corrected Activity Report 4/25/09 5:35:15 PM Paae
~*~**~***~**
- ~+****-&*****.******~*.*
N U C L i D E IDENTIFICATION REPORT Sample
Title:
1-L Liq. Mar'lli Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\ANLOO2.NLB IDENTIFIED NUCLIDES Nuclide Id Name Confidence Energy (key)
K-40 0.979 1460.81*
XE-135 0.994 249.79*
608.18*
PB-212 0.668
- 87. 20 89.80 238. 63*
300.09 BI-214 0.658 609.31*
934.06 1764.49 PB-214 0.664-87.20
- 89. 80 241.98 295.21*
351.92*
Yield
(%)
10.67 89.90 2.89 6.30 1.75 44.60 3.41 46.30 3.21 15.80 3.70 1.03 7.49 19.20 37.20 Activity (uCi/gram) 1.42E-006 3.88E-008 3.32E-006
- 1. 15E-007 2.02E-007
- 2. 37E-007 1.70E-007 Activity Uncertainty 2.44E-007 1.24E-008 5.57E-007 3.52E-008 3.33E-008 6.21E-008 3.90E-008
- = Energy line found in the spectrum.
@ = Energy line not used for Weighted Mean Activity Energy Tolerance :
1.000 keV Nuclide confidence index threshold =
0.30 Errors quoted at 1.000 sigma
Interference Corrected Activity Report 4/25/09 5:35:15 PM Page 4
S I N T E R F E R E N C E C O R R E C T E D R E P O R T Nuclide Nuclide Id Name Confidence K-40
ýXE-135 X
BI-211 PB-212 BI-214 PB-214 0.979 0.994 0.573 0.668 0.658 0.664 Wt mean Activity (uCi/gram)
- 1. 42E-006 3.88E-008
- 1. 15E-007 1.99E-007
- 1. 89E-007 Wt mean Activity Uncertainty 2.44E-007 1.24E-008 3.52E-008 3.33E-008 3.30E-008 Total Activity 1.96E-006
?= nuclide is part of an undetermined solution X
nuclide rejected by the interference analysis
@= nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.000 sigma U N I D E N T I F I E D P E A K S Peak Locate Performed on:
Peak Locate From Channel:
Peak Locate To Channel:
4/25/09 100 4096 5:35:14 PM Peak Energy No.
(keV)
AO, -Z& 6 911.16 M = First peak in a
m = Other peak in a
F = Fitted singlet Peak'Size in Counts per Second 1.44E-002 multiplet region multiplet region Peak CPS
% Uncertainty 36.25 Errors quoted at 1.000 sigma
- ~
GAMMA SPECTRUM ANALY S I S OYSTER CREEK NUCLEAR GENERATING STATION CHEMISTRY DEPARTMENT Detector Name
- DET02 Report Generated On Spectral Data File Name
\\2000080.CNF Sample Title Sample Description User ID Sample Type Sample Geometry Peak Locate Threshold Peak Locate Range (in channels)
Peak Area Range (in channels)
Identification Energy Tolerance 4/26/09 12:01:08 AM C:\\PCNT2K\\CAMFILES\\ILSOLvDA 1-L Solid Releas CST Pit 5' n4283 20 1-L Marinelli 3.00 1-100 -
1.000 4096 4096 k.eV Sample Size 1998.52 grams Sample Taken On Acquisition Started Decay Time 4/25/09 9:45:00 PM 4/25/09 11:44:27 PM 1.19E+002 Minutes Live Real Dead Time Time Time 1000.0 Seconds 1000.2 Seconds 0.02 %
Energy Calibration Used Done On Efficiency Calibration Used Done On 3 /21/08 3 /21/08,
<~ ~
I I ',I~..(-I
,-j~-AC 7-)
i
~?
Background Subtract Report 4./26/09 12:01:08 AM Page BA C K G R O U N D S U B T R A C T R E P O R T Detector Name:
DET02 Sample
Title:
I-L Solid Releas Peak Analysis Performed on:
4/26/09 12:01:08 AM Peak Energy Subtracted No.
(keV)
Uncert.
-/
1 238.37 1.82E+001 2
249.61 1.73E+001 3
351.78
- 1. 08E+0031.7 4
609.31 7.75E+000 j7 5
661.64 8.27E+000 Original Orig. Area Ambient Area Uncert..
Background
Backgr.
Uncert.
- 8. 97E+001 1.74E+002
- 3. 92E+001
- 3. 99E+001
- 3. 94E+001 18.25 17.32 10.75 7.75 8.27 Subtracted Area 8.97E+001 1.74E+002 3.92E+001 3.99E+001 3.94E+001 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
Nuclide MiDA Report 4/'26/09 12:01:09 ;P e
Page NUCLIDE MDA REPORT
-4 '4*
'4 '4
~ ~ '4 * -4 ***
- 4 Detector Name:
DET02 Sample Geometry:
1-L Marinelli Sample
Title:
1-L Solid Releas Nuclide Library Used: C: \\GENIE2K\\CAMFILES\\AnSolMDA.NLB Nuclide Activity Name (uCi/gram)
CS-134 5.49E-008 8 32E-008 2 32E-009
- 9. 22E-009
- 1. 53E-008 2.00E-007
+
- 9. 73E-008 Energy (keV) 563.23 569.32 604.70 795.84 801.93 1365.15 661.65*
Yield
(%)
8.38 15.43 97.60 85.40 8.73 3.04 85.12 Line MDA (uCi/gram) 5.09E-007
- 2. 07E-007 4.23E-068 6.21E-008 5.OOE-007
- 1. 24E-006
+ = Nuclide identified during the nuclide identification
- = Energy line found in the spectrum
> = MDA value not calculated
@ = Half-life too short to be able to perform the decay correction
Interference Corrected Activity Report 4 /2 6/09 12 -.0 1 -09 t*v Page 4
N U C L I D E I D E N T I F I C A T IO N
R E P O R T Sample
Title:
I-L Solid Releas Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSolMDA.NLB IDENTIFIED NUCLIDES Nuclide Id Name Confidence Energy (keV)
Yield Activity
(%)
(uCi/gram)
XE-135 0.961 249.79*
608.18 CS-137 1.000 661.65*
BI-211 0.563 351.10*
404.,80 PB-212 0.666 87.20 89.80 238.63*
300.09 BI-214 0.661 609.31*
934.06 1764.49 89.90 2.89 85.12 12.20 4.10 6.30 1.75 44.60 3.41 46.30 3.21 15.80 1.95E-007
- 9. 73E-008 3.76E-007
- 1. 67E-007
- 1. 68E-007 Activity Uncertainty 2.OOE-008 2.05E-008 1.04E-007 3.41E-008 3.29E-008
- = Energy line found in the spectrum.
a = Energy line not used for Weighted Mean Activity Energy Tolerance :
1.000 keV Nuclide confidence index threshold =
0.30 Errors quoted at 1.000 sigma
2 Interference Corrected Activity Report 4/26/09 12:01:09 AM Page SI N T E R F E R E N C E CRRE C T E D R E P O R T Nuclide Nuclide Id Name Confidence XE-135 CS-137 BI-211 PB-212 BI-214 0.961 1.000 0.563 0.666 0.661 Wt mean Activity (uCi/gram) 1.95E-007 9.73E-008 3.76E-007 1.67E-007 1.68E-007 Wt mean Activity Uncertainty 2.OOE-008 2.05E-008 1.04E-007 3.41E-008 3.29E-008 Total Activity 1.00E-006
? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity
.Errors quoted at 1.000 sigma U N I
D E N T I F I E D P E A K S Peak Locate Performed on:
Peak Locate From Channel:
Peak Locate To Channel:
4/26/09 100 4096 12:01:08 AM Peak Energy No.
(keV)
Peak Size in Counts per Second Peak CPS
% Uncertainty All peaks were identified.
M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
- ****G A M M A S P E C T R U M A N A L Y S I
S******
OYSTER CREEK NUCLEAR GENERATING STATION CHEMISTRY DEPARTMENT Detector Name
- DET03 Report Generated On
- 5/19/09 2:35:45 PM Spectral Data File Name Sample Title Sample Description User ID Sample Type Sample Geometry Peak Locate Threshold Peak Locate Range (in channels)
Peak Area Range (in channels)
Identification Energy Tolerance C:\\PCNT2K\\CANFILES\\lLMARSOL\\1900474.CNF IL Solid Release CST excavation soil composite
- GNT
- 19
- 1-L Liq Marineli 3.00 1 -
4096 100 -
4096 1.000 keV Sample Size 1026.70 g
Sample Taken On Acquisition Started Decd.y Time Live Time Real Time Dead Time 5/19/09 2:30:43 PM 5/19/09 2.:30:43 PM 0.OOE+000 Minutes 300.0 Seconds 300.0 Seconds 0.01 %
Energy Calibration Used Done On Efficiency Calibration Used Done On 5 5/509 5/41/09
ýdL
/
,1'/
,7
.L ~
~
C I:_
~
's&1
Background Subtract Report 5/19/09 2:35:45 PM Page 2
"***B AC K GRO U ND S U BT RA CT R E PO RT***
Detector Name:
DET03 Samule
Title:
IL Solid Release Peak Analysis Performed on:
5/19/09 2:35:44 PM Peak Energy No.
(keV)
Original Orig. Area Ambient Backgr.
Area Uncert.
Background
Uncert.
Subtracted Subtracted Area Uncert.
2 661.29 2.93E+001 1460.56 1.23E+001 6.87 3.69
- 2. 93E+001 1.23E+001
- 6. 87E+000
- 3. 69E+000 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
Nuclide MDA Report 5/19/09 2 :35 :45 PM Page 3
.~*** *********************************************** ************************
IN U C L I D E M D A R E P O R T Detector Name:
DET03 Sample Geometry:
I-L Liq Marineli Sample
Title:
IL Solid Release Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSOLMDA.nlb Nuclide Name CS-134
+
CS-137 Energy (keV) 563.23 569.32 604.70 795.84 801.93 1365.15 661.65*
Yield
(%)
8.38 15.43 97.60 85.40 8.73 3.04
)
(uCi/g
- 9. 27E-007
- 5. 08E-007
- 7. 20E-008
- 1. 04E-007
- 1. 35E-006
- 1. OOE-006
- 1. 66E-007
- 7. 20E-008
-1.32E-007
- 5. 99E-009 1.29E-008 8.49E-008 0.OOE+000 2.17E-007
+ = Nuclide identified during the nuclide identification
- = Energy line found in the spectrum
> = MDA value not calculated
@ = Half-life too short to be able to perform the decay correction
Interference Corrected Activity Report 5/19/09 2:35:45 PM Page 4
N U C L I D E I
D E N T I F I C A T IO N
R EPORT Sample
Title:
IL Solid Release Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\AnSOLMDA.nlb IDENTIFIED NUCLIDES Nuclide Id Name Confidence Energy (keV)
Yield
(%)
Activity Activity (uCi/g
)
Uncertainty K-40 CS-137 0.990 0.979 1460.81*
661.65*
10.67 1.37E-006 85.12 2.17E-007
- 4. lOE-007
- 5. 11E-008
- = Energy line found in the spectrum.
@ = Energy line not used for Weighted Mean Activity Energy Tolerance 1.000 key Nuclide confidence index threshold =
0.30 Errors quoted at 1.000 sigma
Interference Corrected Activity Report 5/19/09 2:35:45 PM Page 5
SI N T E R F E R E N C E C O R R E C T E D R E P 0 R T Nuclide Name K-40 CS-137 Nuclide Id Confidence Wt mean Activity (uCi/g Wt mean Activity Uncertainty 0.990 0.979 1.37E-006
- 2. 17E-007
- 1. 58E-006
- 4. 10E-007
- 5. 11E-008 Total Activity
? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.000 sigma U N I D E N T I F I E D Peak Locate Performed on:
Peak Locate From. Channel:
Peak Locate To Channel:
PEAKS 5/19/09 1
4096 2:35:44 PM Peak Energy No.
(keY)
Peak Size in Counts per Second Peak CPS
% Uncertainty All peaks were identified.
M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.000 sigma
JCGS Radioloaical Survey
]No. Q-0a-cl L36 /q Date S-l.IA-c Time ILocation 0/kVAd RWp Reason
,~
~.'~4-C57 D;A f;L~
t 5. e- (S-A aJ etc4w'C' Acc*S~l~
Afeto A
c,.$51C Rx, Power-IoO 0 %
SMEARABLE CONTAMINATION INSTRUMENTATION DATA LOCATION y
DPM I
RADIATION SURVEY LOCAION DPM AREA MRAD/HR INST aPr-vO,
_S/N
-1 EICF
\\
~COO
". p(-,oc-0 3*
INST N,
4 S/N t-J\\J BCF 5
CDD 6
CONTAMINATION SURVEY 7
I N
4iNST 1 q 9
.CDO
-2.
t-el 10 5 FF 10%
9IKG AjO CPM 11 I
INST 13 14 CF 5Mb CPM is AIR SAMPLE DATA 16 FC NT 17 I________________________L
- Large Area Smear 18 I
NC = Not Counted 19 l
NA. Not Applicable 20_
NT = Not Taken Surveyyr:(Print Name),
8,.4
- =Gamma G.A
=Smear SIgntr Date
,."lro*t i# B = Beta DF - Direct Frisk Reviewer: (PrmF1,Nan"a),,,-
V I
N N Neutron IX e,
-=- Raod ound M
,&u'/0 0
- /*=
Contact130cm r
- 1; Beta /I Conta 1d= Head
=4Chest. Kn = Knee. W = Waist
- B /
BetaI 30cm All dose rates in mremlhr unless otherwise noted
-No Beta Detected Unless Otherwise Noter' No Bets Reading. Taker No Eo,t Ul 0th t
0 COPY