{{#Wiki_filter:,_ _ _ _ _ __ _ _ _ _ _ _ . . - _ _ _ _ _ _ __ . _ _ _ _ _ _ CPS-0DCM
'h ILLENOIS POWER COMPANY' DOCUMENT conygog FEB 221989 FOR REFERENCE '
ILLINOIS POWER COMPANY CLINTON POWER STATloN l l CLINTON POWER STATION , UNIT 1 0FFSITE DOSE CALCULATION MANUAL
\
Docket No. 50-461 O . O CLINTON-I Rev.5-2/89 8903170357 890307 DR ADOCK0500gg<;l
CPS-ODCM
. ,s Revision 5 Summary ;
! '-) ( Page j 1 Changed page numbers for Sections 2.5 and 2.6. I iv Delete reference to Table 2.6-1, revise titles for Tables 3.5-13 through 3.5-16. v Revise titles for Tables 3.5-17 through 3.5-31. vi Add a new Figure 2.5-3. vii Revise List of Effective pages. 2-1 Deleted reference to FSAR, replaced with USAR in paragraph 2.1. 2-3 , Correction in Section 2.3.1.1 referencing CPS RETS Table 4.11.1 ; to Table 4.11.1-1. i 2-6 Replaced Figure 2.1-1 due to map being illegible, s 2-9 Revised the definition for *.he quantity F1 , the near field average dilution factor 2-11 Revised Table 2.4-1 Aij factors for the P-32 due to the latest r~ NRC recommended value for the bioaccumulation factor for (_)g phosphorus, and Sr-91. 2-12 Revised Table 2.4-1 Aij factors for Te-125m. 2-13 Revised Table 2.4-1 Aij factors for Ba-139. 2-14 Changed the bioaccumulation factor (BFi) for freshwater fish for phosphorus due to the latest NRC recommendation. 2-15 Revised Table 2.4-3 DFi factors for Sr-91. 2-16 Revised Table 2.4-3 DFi factors for Te-127m, Te-129m, and 1-133. 2-17 Revised Table 2.4-3 DFi factors for Ba-139. 2-18 Revised Figure 2.5-1 to reflect actual plant nomenclature. 2-20 Add new Figure 2.5-3 SOLID RADWASTE SYSTEM SIMPLIFIED FLOW DIAGRAM. Rev. 2 verbage becomes page 2-21, 2-21 Rev. 2 page 2-20 verbage becomes new page. Rev. 2 page 2-21 containing Table 2.6-1 deleted. 2-22 Removed this page since Table 2.6-1 was deleted in Rev. 2. 3-5 Placed the symbol which indicates rate (.) over the Qim instead of (X/Q)m, deleted reference to "j" for summation, and corrected definition of Mi by changing mrem to mrad. CLINTON-I 1 Rev. 5-2/89 j
CPS-ODCM Revision 5 Summary O P age 3-9 Revised Table 3.4-2 Pij factors for Cu-64 and Br-85. l 3-10 Revised Table 3.4-2 Pij factors for Y-91m. 3-14 Included the units in the definition for the quantities (X/Q)m , and (x/q)m. l 3-16 Corrected the units in the definition for the quantity gim which should be uCi instead of C1. 3-19 Added the definition for Ys. 3-20 Corrected definition for lambda w, by changing half-time to 1
, half-life.
3-28 Changed the units for Skin Dose Factor (Li) to mrem /yr per uCi/m3 . 3-30 Replaced Figure 3.1-1 due to map being illegible. 3-32 Revised Table 3.5-1 (DFAi)a factors for P-32 to agree with RG 1.109. ( ) 3-33 Revised Table 3.5-1 (DFA1)a factors for Zr-95, Te-127, and I-133 to agree with RG 1.109. 3-34 Revised Table 3.5-1 (DFA1)a factors for Cs-137 and Ba-139 to agree with RG 1.109. 3-35 Revised Table 3.5-2 (DFA1)a factors for Cr-51 to agree with RG , 1.109. 3-39 Revised Table 3.5-3 (DFA1)a factors for Nb-95 to agree with RG ." 1.109. 3-40 Revised Table 3.5-3 (DFAi)a factors for La-142 and Nd-147 to agree with RG 1.109.
^
3-41 Revised Table 3.5-4 (DFA1)a factors for Zn-69 to agree with RG 1.109. 3-43 Revised Table 3.5-4 (DFAi)a factors for Ba-140 and Ce-144 to agree with RG 1.109. 3-44 Correct element number for Co-60. 3-45 Revised Table 3.5-5 DFGi skin factor for Te-131 to agree with RG 1.109. ( 3-49 Revised Table 3.5-7 (DFLi)a factors for P-32 to agree with RG
~
1.109. CLINTON-I 2 Rev. 5-2/89
CPS-0DCM 1 I i Revision 5 Summary l l Page 3-50 Revised Table 3.5-7 (DFLi)a factors for Y-91m and Te-127 to agree with RG 1.109. 3-53 Revised Table 3.5-8 (DFLi)a factors for Zr-95 to agree with RG 1.109. , 3-56 Revised Table 3.5-9 (DFL1)a factors for Y-93 to agree with RG 1.109. 3-61 Changed Table 3.5-13 to read Inhalation Pathway Factors following the convention used in NUREG-0133. 3-62 Changed Table 3.5-13 to read Inhalation Pathway Factors following the convention used in NUREG-0133. Corrected values
'for Ru-103.
3-63 Changed Table 3.5-13 to read Inhalation Pathway Factors I following the convention used in NUREG-0133. Corrected values for I-134 and Ba-141. 3-64 Changed Table 3.5-14 to read Inhalation Pathway Factors followin Corrected values for Br-8g4the andconvention Rb-89. used in NUREG-0133. : O 3-65 Changed Table 3.5-14 to read Inhalation Pathway Factors following the convention used in NUREG-0133. 3-66 Changed Table 3.5-14 to read Inhalation Pathway Factors i following the convention used in NUREG-0133. 3-67 Changed Table 3.5-15 to read Inhalation Pathway Factors following the convention used in NUREG-0133. Corrected values for Rb-86 and Sr-89. 3-68 Changed Table 3.5-15 to read Inhalation Pathway Factors following the convention used in NUREG-0133. Corrected values for Te-127 and I-130. 1 3-69 Changed Table 3.5-15 to read Inhalation Pathway Factors following the convention used in NUREG-0133. 3-70 Changed Table 3.5-16 to read Inhalation Pathway Factors - following the convention used in NUREG-0133. 3-71 Changed Table 3.5-16 to read Inhalation Pathway Factors following the convention used in NUREG-0133. Corrected values for Tc-101.
/~ 3-72 Changed Table 3,5-16 to read Inhalation Pathway Factors
(_)' following the convention used in NUREG-0133. l l l l CLINTON-1 3 Rev. 5-2/89 _ _ ._-____________-___-__________-_______-_A
CPS-0DCM ; l _s Revision 5 Summary Page 3-73 Changed Table 3.5-17 to read Cow Milk Pathway Factors following the convention used in NUREG-0133. Revised values for C-14, Zn-65 and Sr-91. 3-74 Changed Table 3.5-17 to read Cow Milk Pathway Factors following the convention used in NUREG-0133. Revised values for Zr-97, Nb-95,,Tc-101, Ru-103, Te-127 and Te-129. 3-75 Changed Table 3.5-17 to read Cow Milk Pathway Factors following the convention used in NUREG-0133. Revised values for Cs-138, Ba-139 and Ba-140. Clarified units for table as noted by "*". 3-76 Changed Table 3.5-18 to read Cow Milk Pathway Factors following
.the convention used in NUREG-0133. Revised values for C-14, Zn-65 and Sr-90.
3-77 Changed Table 3.5-18 to read Cow Milk Pathway Factors following the convention used in NUREG-0133. Revised values fbr Nb-95, Tc-99m, Tc-101, Te-127, Te-129 and I-131. 3-78 Changed Table 3.5-18 to read Cow Milk Pathway Factors following the convention used in NUREG-0133. Revised values for Cs-138,
<N Ba-139, Ba-140, La-140 and Ce-141. Clarified units for table
() as noted by "*". 3-79 Changed Table 3.5-19 to read Cow Milk Pathway Factors following the convention used in NUREG-0133. Revised values for C-14 and Fe-59. 3-80 Changed Table 3.5-19 to read Cow Milk Pathway Factors following . the convention used in NUREG-0133. Revised values for Nb-95, ! Tc-101, Te-127, Te-129 and Te-131. l 3-81 Changed Table 3.5-19 to read Cow Milk Pathway Factors following ' the convention used in NUREG-0133. Revised values for Cs-138, Ba-139, Ba-140 and Ce-141. Clarified units for table as noted by "*". 3-82 Changed Table 3.5-20 to read Cow Milk Pathway Factors following the convention used in NUREG-0133. Revised values for C-14. 3-83 Changed Table 3.5-20 to read Cow Milk Pathway Factors following the convention used in NUREG-0133. Revised values for Y-91m, Zr-97, Nb-95, Tc-101, Te-127 and Te-129. 3-84 Changed Table 3.5-20 to read Cow Milk Pathway Factors following the convention used in NUREG-0133. Revised values for Cs-138 and Ba-139. Clarified units for table as noted by "*". CLINTON-I 4 Rev. 5-2/89 )
CPS-ODCM j 1
- Revision 5 Summary l
( ' Page . I 3-85 Changed Table 3.5-21 to read Goat Milk Pathway Factors following the convention used in NUREG-0133. Revised values for C-14, P-32 and Ni-63. 1 3-86 Changed Table 3.5-21 to read Goat Milk Pathway Factors j following the convention used in NUREG-0133. Revised values I for Nb-95, Tc-101, Ru-105, Te-127 and Te-129. l 3-87 Changed Table 3.5-21 to read Goat Milk Pathway Factors following the convention used in NUREG-0133. Revised values for Cs-134, Cs-138, Ba-139 and Pr-144. Clarified units for table as noted by "*". 3-88 . Changed Table 3.5-22 to read Goat Milk Pathway Factors following the convention used in NUREG-0133. Revised values for C-14 and Zn-65. 3-89 Changed Table 3.5-22 to read Goat Milk Pathway Factors following the convention used in NUREG-0133. Revised values for Nb-95, Tc-101, Te-127, Te-129, and I-132. 3-90 Changed Table 3.5-22 to read Goat Milk Pathway Fa:rors following the convention used in NUREG-0133. Revised values (G) for Cs-138, Ba-139, La-140 and Ce-141. Clarified units for i table as noted by "*". ] 3-91 Changed Table 3.5-23 to read Goat Milk Pathway Factors following the convention used in NUREG-0133. Revised values ! for C-14 and Fe-55. 3-92 Changed Table 3.5-23 to read Goat Milk Pathway Factors j following the convention used in NUREG-0133. Revised values for Nb-95, Tc-101, Ru-105, Te-127 and Te-129. 3-93 Changed Table 3.5-23 to read Goat Milk Pathway Factors ! following the convention used in NUREG-0133. Revised values I for Cs-138, Ba-139 and Ce-141. Clarified units for table as l noted by "*". 3-94 Changed Table 3.5-24 to read Goat Milk Pathway Factors following the convention used in NUREG-0133. Revised values l for C-14.
]
3-95 Changed Table 3.5-24 to read Goat Milk Pathway Factors ! following the convention used in NUREG-0133. Revised values for Nb-95, Tc-101, Te-127, Te-129, Te-131m and I-132. l l CLINTON-I 5 Rev. 5-2/89
L CPS-ODCM Revision 5 Summary
> (~\
(_/ Page 3-96 Changed Table 3.5-24 to read Goat Milk Pathway Factors following the convention used in NUREG-0133. Revised values ; for Cs-137, Cs-138, Ba-139 and Nd-147. Clarified units for , table as noted by "*". i 3-97 Changed Table 3.5-25 to read Meat Pathway Factors following the convention used in NUREG-0133. Revised values for C-14, 2n-65 and Zn-69. 3-98 Changed Table 3.5-25 to read Meat Pathway Factors following the convention used in NUREG-0133. Revised values for Nb-95, Ru-105, Te-127, Te-131m, Te-131 and I-133. 3-99 Changed Table 3.5-25 to read Meat Pathway Factors following the convention used in NUREG-0133. Revised values for I-135, ; Cs-138, Ba-139, La-140, Ce-141 and W-187. Clarified units for table as noted by "*". 3-100 Changed Table 3.5-26 to read Meat Pathway Factors following the convention used in NUREG-0133. Revised values for C-14, Ni-65 and Zn-65. i
,s 3-101 Changed Table 3.5-26 to read Meat Pathway Factors following the convention used in NUREG-0133. Revised values for Zr-95, f' ') Nb-95, Te-127 and I-133.
l l 3-102 Changed Table 3.5-26 to read Meat Pathway Factors following the : convention used in NUREG-0133. Revised values for Cs-138. ! Clarified units for table as noted by "*". 3-103 Changed Table 3.5-27 to read Meat Pathway Factors following the convention used in NUREG-0133. Revised values for C-14 and Zn-65. 3-104 Changed Table 3.5-27 to read Meat Pathway Factors following the convention used in NUREG-0133. Revised values for Y-92, Nb-95, j Te-127 and I-133. 3-105 Changed Table 3.5-27 to read Meat Pathway Factors following the convention used in NUREG-0133. Revised values for Cs-138 and Pr-143. Clarified units for table as noted by "*". 3-106 Changed Table 3.5-28 to read Vegetation Pathway Factors following the convention used in NUREG-0133. Revised values for Na-24, Cr-51, Cu-64, Br-83, Br-84 and Rb-88. 3-107 Changed Table 3.5-28 to read Vegetation Pathway Factors following the convention used in NUREG-0133. Revised values gg for Nb-95, Tc-101, Te-127 and Te-129. j
\/
CLINTON-I 6 Rev. 5-2/89
CPS-0DCM 7
-s Revision 5 Summary Page 3-108 Changed Table 3.5-28 to read Vegetation Pathway Factors following the convention used in NUREG-0133. Revised values for I-135, Cs-138, La-140, Ce-141 and Nd-147. Clarified units for table as noted by "*".
3-109 Changed Table 3.5-29 to read Vegetation Pathway Factors following the convention used in NUREG-0133. Revised values for Zn-69, Br-83 and Br-84. 3-110 Changed Table 3.5-29 to read Vegetation Pathway Factors following the convention used in NUREG-0133. Revised values for Nb-95, Tc-101 and Te-129. 3-111 . Changed Table 3.5-29 to read Vegetation Pathway Factors following the convention used in NUREG-0133. Revised values for Cs-138. Clarified units for table as noted by "*". 3-112 Changed Table 3.5-30 to read Vegetation Pathway Fact 6rs following the convention used in NUREG-0133. Revised values for Br-83, Br-84 and Sr-90. 3-113 Changed Table 3.5-30 to read Vegetation Pathway Factors
/~T following the convention used in NUREG-0133. Revised values (J for Nb-95, Tc-101, Te-127 and Te-129.
3-114 Changed Table 3.5-30 to read Vegetation Pathway Factors following the convention used in NUREG-0133. Revised values for I-135, Cs-138, Ce-141 and W-187. Clarified units for table as noted by "*". 3-115 Changed Table 3.5-31 to read Ground Plane Pathway Factors following the convention used in NUREG-0133. Revised values for Nb-95, Cs-134 and Cs-138. 4 CLINTON-1 7 Rev. 5-2/89
' CPS-0DCM i l
l Illinois Power Company ILLINOIS POWER COMPANY DOCUMENT CONTROL' j f7 : (_j Clinton Power Station 1 0FFSITE DOSE CALCULATION MANUAL FE8 22 IS89 i i FOR REFERENCE Table of Contents ~ CUNTON PCWER STATION Section- Title Page 1.0 PREFACE l-1 2.0 LIQUID EFFLUENTS 2-1 2.1 Introduction 2-1 2.2 Liquid Radwaste Discharge Process Radiation 2-1 Monitoring (PRM)' System 2.2.1 Method of Representative Sampling 2-1 2.3 10CFR20 Release Rate Limits 2-1 ( 2.3.1 Liquid Radwaste Discharge PRM 2-2 Setpoints 2.3.2 Plant Service Water Effluent 2-7 PRM Setpoints-
. 2.3.3 Shutdown Service Water (SX) Effluent 2-8 PRM Setpoints
- 2. 3.4 Fuel Fool Heat Exchanger Service '
2-8 Water Effluent PRM Setpoints l 2.4 10CFR50, Appendix I Release Rate Limits 2-9 2.5 Compliance With CPS RETS 3.11.1.3/3.11.1.4 2-21 . 2.6 Doses From Other Significant Liquid Effluent Pathways 2-21 3.0 GASEOUS EFFLUENTS 3-1 3.1 Introduction 3-1 3.2 Gaseous Effluent Release Point Monitoring 3-2 () 3.2.1 HVAC Stack Process Radiation Monitoring (PRM) System 3-2 CLINTON-I i Rev.5-2/89 L _ _ _ _ _ - _ _ - - - - -
CPS-0DCM Table of Contents Section Titic Page 3.0 3.~2.2 SGTS Stack Process Radiation 3-2 Monitoring (PRM) System 3.3 Main Condenser Off-Gas Monitoring System 3-3 3.3.1 Pre-Treatment Air Ejector Off-Gas 3-3 FRM 3.3.2 Post-Treatment Air Ejector Qff-Gas 3-4 PRM 3.4 10CFR20 Release Rate Limits 3-4 3.4.1 Dose Rate Due to Noble Gases 3-5 3.4.2 Dose Rate Due to Radiciodines, 3-5 Particulate and Tritium 3.5 10CFR50, Appendix I Release Rate Limits 3-13 3.5.1 Noble Gas Air Dose 3-13 3.5.2 Radioiodines, Particulate and 3-15 Tritium Dose . 3.6 Compliance With CPS RETS 3.11.2.4/3.11.2.5 3-25 3.7 Effluent Monitor Setpoint Calculations 3-25
~
3.7.1 Total Body Dose Rate Setpoint 3-26 3.7.2 Skin Dose Rate Setpoint 3-28 4.0 COMPLIANCE WITH 40CFR190 4-1 5.0 RADIOLOGICAL ENVIRONMENTAL MONITORING 5-1 5.1 Interlaboratory Comparison Program 5-1 6.0 ADJUSTMENT OF THE CPS ODCM METHODOLOGY 6-1 l 7-1 7.0 ATMOSPHERIC TRANSPORT AND DISPERSION MODEL O CLINTON-I 11 Rev.2-10/86
. CPS-0DCM s
n , b-)) L, Table of Contents Section Title Page 7.0 7.1 Introduction 7-1 7.2 -Historical Meteorological Data Processing 7-1 7.2.1 Numerical Model 7-2 7.2.2 Source Configuration Considerations 7-3 7.2.3 Relative Deposition Factor 7-4 7.3 Concurrent Meteorological Data Processing 7-17 1 7.3.1 Determination of Pasquill Stability 7-17 Class 7.3.2 Calculation of Stack Height Wind 7-18 Speed 7.3.3 Determination of Release Mode and the 7-19 Entrainment Coefficient PE 7.3.4 Calculation of Vertical Standard 7-20 ,
- Deviation .
i
. 7.3.5 Calculation of the Building Wake 7-20 l Correction l 7.3.6 Calculation of Momentum Plume Rise 7-21 7.3.7 Calculation of Effective Plume Height 7-22 ; ~ '
7.3.8 Determination of Affected Sectors 7-22
! 7.3.9 Calculation of Depletion and 7-23 1 Deposition Factors t
7.3.10 ' Ground Level X/Q, D2DPXQ, DlXQ, D/Q 7-27 Analysis
;- 7.3.11 Elevated X/Q, D2DPXQ, D1XQ, i D/Q Analysis 7-29 7.3.12 Short Term Dispersion Calculations 7-30 1
CLINTON-I iii Rev.1-11/85
7_ _ _ - CPS-0DCM i l Tables g Table Title Page 2.4-1 Adult Ingestion Dose Commitment Factors-At3 2-11 2.4-2 Bioaccumulation Factors-BF 1 2-14 2.4-3 Adult Ingestion Dose Factors-DFt 2-15 3.4-1 Dose Factors For Noble Gases and Daughters 3-8 3.4-2 Inhalation Pathway Dose Rate Factors (CHILD)-Pt 3-9 3.4-3 Annual Doses in Unrestricted Arcos 3-12 1 3.5-1 Inhalation Dose Factors For Infant-(DFAt)a 3-32 3.5-2 Inhalation Dose Factors For Child-(DFA1 ), 3-35 3.5-3 Inhalation Dose Factors For Teen-(DFAt)a 3-38 3.5-4 Inhalation Dose Factors For Adult-(DFA1 ), 3-41 3.5-5 Ground Plane Dose Factors-DFG 1 3-44 3.5-6 Ingestion Dose Factors For Infant-(DFLt ), 3-46 , 3.5-7 Ingestion Dose Factors For Child-(DFL1 )a 3-49 3.5-8 Ingestion Dose Factors For Teen-(DFLt ), 3-52 3.5-9 Ingestion Dose Factors For Adult-(DFLt ), 3-55 C 3.5-10 Input Parameters For Calculating R , 3-58 3 3.5-11 Input Parameters For Calculating R 13 3-59 3.5-12 Input Parameters For Calculating R 3-60 3 3.5-13 Inhalation Pathway Factors - R (INFANT) 3-61 3.5-14 Inhalation Pathway Factors - R (CHILD) 3-64 3.5-15 Inhalation Pathway Factors - R (TEEN) 3-67 I 3.5-16 Inhalation Pathway Factors - R aij (ADULT) 3-70 ( (d' l CLINTON-I iv Rev.5-2/89 ! l I 1
LCPS-ODCM
> l l
Tables l Table Title Page ! 3.5-17 Cow Milk Pathway Factors - R 13 (INFANT) 3-73 C 3.5-18 Cow Milk Pathway Factors - R j (CHILD) 3-76 3.5-19 1 CowMilkPathwayFactors-Rff) (TEEN) 3-79 3.5-20 Cow Milk Pathway Factors - R (ADULT) 3-82 3.5-21 Goat Milk Pathway Factors - R (INFANT) 3-85 3.5-22 Goat Milk Pathway Factors - R,C ij (CHILD) 3-88 C 3.5-23 ' Goat Milk Pathway Factors - R {j (TEEN) 3-91 3.5-24 Goat Milk Pathway Factors - R (ADULT) 3-94 3.5-25 Meat Pathway Factors - R g) (CHILD) 3-97 3.5-26 Meat Pathway Factors - R 13 (TEEN) 3-100 M 3-103 3.5-27 Meat Pathway Factors - R j (ADULT) 3.5-28 Vegetation Pathway Factors - R (CHILD) 3-106 3.5-29 Vegetation Pathway Factors - R () (TEEN) 3-109 3.5-30 Vegetation Pathway Factors - R () (ADULT) 3-112 ! 3.5.31 - Ground Plane Pathway Factors - R C 3-115 ) 5.0-1 Radiological Environmental Monitoring Program , ! Sampling and Collection Frequencies 5-3 l 7.2-1 Annual Average Mixed-Mode X/Q 7-6 7.2-2 Annual Average Mixed-Mode D/Q 7-10 7.2-3 Wind Speed and Wind Direction Classification 7-14 7.2-4 Gaseous Effluent Release Point Characteristics 7-15 7.2-5 Site Boundary Dispersion and Deposition Parameters 7-16 lO I CLINTON-I v Rev.5-2/89 l
CPS-0DCM Figures
'~
Figure Title Page 2.1-1 Unrestricted Arca Boundary For Liquid Effluents 2-6 2.5-1 Liquid Radwaste Treatment System 2-18 2.5-2 Shutdown and Fuel Pool Heat Exchanger Service Water Effluent Monitors 2-19 2.5-3 Solid Radwaste System Simplified Flow Diagram 2-20 3.1-1 CPS Site Boundary For Gaseous Effluents 3-30 3.3-1 Main Condenser Off-Gas Treatment System 3-31 j 5.0-1 REMP Locations Within 1.5 Miles of CPS 5-13 5.0-2 REMP Locations Within 6 Miles of CPS 5-14 ! 5.0-3 REMP Locations Within 50 Miles of CPS 5-15 e kJ s CLINTON-I vi Rev.5-2/89 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - - - - _ _ _ _ )
l
, CPS-0DCM I
i l List of Effective Pages l 1 # (~) Page Revision Page Revision Page Revision Page Revision l 1 5 3-16 5 3-65 5 4-1 1 11 2 3-17 1 3-66 5 5-1 2 111 1 3-18 1 3-67 5 5-2 2 ! iv 5 3-19 5 3-68 5 5-3 1 v 5 3-20 5 3-69 5 5-4 1 vi 5 3-21 1 3-70 5 5-5 1 , vii 5 3-22 1 3-71 5 5-6 2 i 1-1 1 3-23 1 3-72 5 5-7 1 2-1 5 3-24 1 3-73 5 5-8 2 2-2 4 3-25 2 3-74 5 5-9 3 2-3 5 3-26 1 3-75 5 5-10 2 2-4 4 3-27 2 3-76 5 5-11 1 2-5 4 3-28 5 3-77 5 5-12 2 2-6 5 3-29 2 3-78 5 5-13 3 2-7 3 3-30 5 3-79 5 5-14 3 2-8 2 3-31 2 3-80 5 5-15 2 2-9 5 3-32 5 3-81 5 6-1 2 > 2-10 1 3-33 5 3-82 5 7-1 2 2-11 5 3-34 5 3-83 5 7-2 1 2-12 5 3-35 5 3-84 5 7-3 1 2-13 5 3-36 1 3-85 5 7-4 1 2-14 5 3-37 1 3-86 5 7-5 1
/~ 2-15 5 3-38 3-87 5 7-6 2
()' 2-16 5 3-39 1 5 3-88 5 7-7 7-8 2 2-17 5 3-40 5 3-89 5 2 2-18 5 3-41 5 3-90 5 7-9 2 2-19 2 3-42 1 3-91 5 7-10 2 2-20 5 3-43 5 3-92 5 7-11 2 2-21 5 3-44 5 3-93 5 7-12 2 , 3-1 2 3-45 5 3-94 5 7-13 2 ! 3-2 1 3-46 1 3-95 5 7-14 1 3-3 2 3-47 1 3-96 5 7-15 2 3-4 2 3-48 1 3-97 5 7-16 '4 3-5 5 3-49 5 3-98 5 7-17 2 3-6 2 3-50 5 3-99 5 7-18 1 3-7 1 3-51 1 3-100 5 7-19 1 3-8 1 3-52 1 3-101 5 7-20 1 3-9 5 3-53 5 3-102 5 7-21 2 3-10 5 3-54 1 3-103 5 7-22 1 3-11 2 3-55 1 3-104 5 7-23 1 3-12 4 3-56 5 3-105 5 7-24 1 3-13 2 3-57 1 3-106 5 7-25 1 3-14 5 3-58 1 3-107 5 7-26 2 3-15 1 3-59 1 3-108 5 7-27 1 3-60 1 3-109 5 7-28 1 3-61 5 3-110 5 7-29 1 3-62 5 3-111 5 7-30 1 3-63 5 3-112 5 7-31 1 () 3-64 5 3-113 3-114 5 5 3-115 5 CLINTON-I vii Rev.5-2/89
CPS-0DCM. , N 1.0 PREFACE The Clinton Power Station OFFSITE DOSE CALCULATION MANUAL (CPS-0DCM) provides the methodologies and parameters to be used by
, Illinois Power Company (IPC) to assure compliance with the dose l limitations stated in the CPS Radiological Effluent Technical . Specifications (CFS RETS). The RETS show compliance with 10CFR20, l 10CFR50 Appendix A (GDC60 and 64), 10CFR50 Appendix I, and i 40CFR190. . ! The CPS-0DCM was prepared based on guidance provided in NUREG-0133, l PREPARATION OF RADIOLOGICAL EFFLUENT TECHNICAL SPECIFICATIONS FOR NUCLEAR POWER PLANTS (October 1978), and NUREG-0473, RADIOLOGICAL I
EFFLUENT TECHNICAL SPECIFICATIONS FOR BOILING WATER REACTORS-l (Draft 7" to Revision 3). This manual along with station procedures will be used by CPS personnel to demonstrate compliance with the CPS RETS.
- j. Changes to the CPS-0DCM shall be provided in the SEMIANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT.
O I 1 l i > l !
- i l I
\ ~
l O CLINTON-I l-1 Rev.1-11/85 i
CPS-0DCM 2.0 LIQUID EFFLUENTS () 2.1 Introduction Liquid radwaste effluent released from CPS will meet 10CFR20 ! concentration limits at the point of discharge to the unrestricted l area shown in Figure 2.1-1. This design and operation objective l will be achieved at all times. Actual discharges of liquid radwaste effluent will occur on a batch basis and the average l concentration at the point of discharge will normally be only a I small percentage of the allowed limits. Reference Clinton USAR Section 11.5 for a description of radiation monitoring, sampling and effluent control systems. Cumulative quarterly dose contributions due to radioactive effluents released to the unrestricted area will be determined once every 31 days using NUREG-0133 and Regulatory Guide 1.109 methodology and parameters. 2.2 Liquid Radwaste Discharge Process Radiation Monitoring (PRM) System This monitoring subsystem measures liquid radwaste effluent radioactivity prior to the effluent joining plant service water and circulating water dilution streams. A high radioactivity signal from this gamma scintillation detector automatically terminates the , liquid radwaste effluent release. The liquid radwaste effluent l flow, variable from 10-60 GPM or 50-300 GPM, combines with Plant O' l Service Water flow (minimum flow approximately 5000 GPM during plant shutdown periods depending on system loads) and Plant Circulating Water flow (0-567,000 GPM) in the Seal Well prior to entering the 3.4 mile discharge flume to Lake Clinton (see Figure 2.5-1). 2.2.1 Method of Representative Sampling To obtain a representative sample of the liquid radwaste tank to be discharged, the tank is isolated from all iniuts and recirculated a minimum of two tank volumes at which time a sample is obtained for isotopic analysis. 2.3 10CFR20 Release Rate Limits The requirements pertaining to discharge of liquid radwaste effluent to the unrestricted area are specified in CPS RETS 3.11.1.1: CLINTON-I 2-1 Rev.5-2/89
, CPS-0DCM ,-);
( k-
"The concentration of radioactive material released in liquid effluents to UNRESTRICTED AREAS shall be limited to the concentrations specified in 10CFR20, Appendix B, Table II, Column 2 for non-noble gas radionuclides. For dissolved or entrained noble gases, the concentration shall be limited to 2E-049Ci/ml total activity." j To comply with the above requirements, setpoints will be calculated to assure that Seal Well concentrations do not exceed 10CFR20, Appendix B, Table II, Column 2 values at any time.
2.3.1 Liauid Radwaste Discharge PRM Setpoints To achieve CPS RETS 3.11.1 1, and for the purpose of implementation of CPS RETS 3.3.7.11, the alarm / trip setpoints for liquid effluent monitors and flow measurement devices are set to assure that the following equation is satisfied: cf <CMPC (1) F+f-C MPC
= the effluent concentration limit (CPS RETS 3.11.1.1) implementing 10CFR20 for the site, corresponding to the specific mix of radionuclides p' l in the effluent stream being
(,-) considered, in UCi/ml
\~-) '
c = the setpoint, inp Ci/ml, of the radioactivity monitor measuring the radioactivity concentration in the effluent line prior to dilution and subsequent release; the setpoint is inversely proportional to the volumetric flow of the effluent line and proportional to the volumetric flow of the dilution stream (s) plus the effluent stream. F = the dilution water flow setpoint as determined at the Seal Well, in volume per unit time f = The liquid radwaste discharge flow setpoint as determined at the liquid radwaste discharge PRM 1ccation, in volume per unit time (same units as F) l O CLINTON-I 2-2 Rev.4-10/88 1
CPS-ODCM l The available dilution water flow (F) should be constant for a (x given release, and the liquid radwaste tank discharge flow (f) and monitor setpoint (c) are set to meet the condition of equation (1) I for a given effluent concentration (Cup The method by which thisisaccomplishedisillustratediHhe)c.tions 2.3.1.1 through , 2.3.1.5. 2.3.1.1 The isotopic concentration for a liquid radwaste tank to be discharged is obtained from the sum of the measured I concentrations as determined by the analyses required in CPS l RETS Table 4.11.1-1: [Cf
=
C+3C + gg a [C +C g +CFe T , p Ci/ml (2) l l where jC g - The sum of concentrations C f ah 8 measured gamma emitter g (including I-131) observed by gamma spectroscopy of the waste sample, ' pCi/ml. IC = The sum of concentrations C of alpha emitters (a) aa in liquid radwaste as measufed in the most current QUARTERLY composite discharge tank sample,pCi/ml. O IC = The sum of concentrations C 8 of Sr-89/Sr-90 in I V 8 8 liquid radwaste as observed 1n the most current QUARTERLY composite discharge tank sample,yCi/ml. C T
= The measured concentration of H-3 in liquid radwaste as determined from analysis of the most current ,
QUARTERLY composite discharge tank sample,pCi/ml. I C = The measured concentration of Fe-55 in liquid Fe radwaste as observed in the most current QUARTERLY composite discharge tank sample,yCi/ml. O CLINTON-1 2-3 Rev.5-2/89
CPS-0DCM
, ,) 2.3.1.2 The measured radionuclides concentrations are used to L-f calculate a DILUTION FACTOR (DF) which is equivalent to the ratio of total dilution flow rate to liquid radwaste tank effluent flow rate required to assure that the limiting concentrations of 10CFR20, Appendix B, Table II, Column 2 are met at the point of discharge to the unrestricted area.
DF = SF rC i (3) I RFUT l' dimensionless 1 C
= r Cg +t a 4
C s_ , C T , C Fe
)
SF [8MPC "MPC MPC MPC T MPC Fe g a 3 where .. Og = The~ measured concentrations Cg, C, a C,s C T' - C as defined in equation (2), pCi/ml. Fe MPC g = The limiting concentration of the corresponding radionuclides MPC , MFC,, MPC , MPC T, MPC f#
- g s Fe 10CFR20, Appendix B, Table II, Column 2,pCi/ml.
For dissolved or entrained noble gases, the concentration shall be limited to 2E-04pci/ml total activity. L2 l SF = The conservative SAFETY FACTOR normally applied to l ('r#) compensate for statistical fluctuations and ', measurement errors, dimensionless, 2.3.1.3 The maximum permissible liquid radwaste tank effluent flow rate, Frank, is calculated by the following equation: Ftank = 0.9 (Fdil + ftank), y lume/ time (4) DF f I where j F = Miminum expected dilution water flow rate dil 1 (Circulating and/or Service Water systems), I volume / time ftank = Maximum expected liquid radwaste tank effluent flow rate, volume / time 0.9 == Flow rate correction factor to provide a 10% margin
. for variations in flow rates, dimensionless DF = The DILUTION FACTOR calculated by equation (3),
dimensionless
- CLINTON-I 2-4 Rev.4-10/88 i l
l l 1
CPS-0DCM f'h Equation (4) is valid only for DF>- 1; for DF< 1, the li uid '
'\-[ 'radwaste tank effluent concentration meets the limits o 10CFR20 without dilution and therefore F tank may ar,sume any value: not to exceed discharge pump capacity.
2.3.1.4 The liquid.radwaste discharge PRM setpoint may now be .. specified based on the values ofr Cg f (Eq.2) and Ftank (Eq.4) which were-determined to provide compliance with the concentration limits of 10CFR20, Appendix B, Table II,' Column
- 2. The monitor response.is primarily a. gamma response and the actual setpoint is therefore based on ICg g (Eq.2). .The monitor setpoint, in counts per minute (cpm), which' corresponds to the particular setpoint concentration, C g,ris determined based on monitor calibration data or operational data which correlates monitor response to sample analyses associated with.the actual liquid radwaste discharged. The second method is considered valid only if the integrity of laboratory methods of determination are proven more accurate than the monitor data.
1 The set point concentration, C g, is obtained by the following equation: C
~M - ( F tank) I C , V Ci/ml 88 (5) i f
act : where ; i , I f = The actual liquid radwaste act effluent flow rate, volume / time If (F tank / fact}f 1, the value obtained for Cg is used to determine the moni tor setpoint above background, ccpm, . from either of the two methods described above. In the case where ! (F <1 no release may be made using the existing ' die 88Ir/fgcha)rame,tervalues(DF,Ftank, g fact)* The setpoint concentration is conservative, even if Ftank is attainable , since the calculated flow rate contains the SAFETY FACTOR, dilution flow rate and liquid radwaste tank effluent flow rate margins, t 2.3.1.5 To prevent spurious alarms, revise the Plant Service Water Effluent PRM setpoint to coincide with the setpoint concentration, C, calculated by equation (5). This setpoint is valid only duYing periods of actual liquid radwaste discharges.
/~% \
nd CLINTON-I '2-5 Rev.4-10/88 l l
.O S Y O E O DI S N T R. E WWW O O R - R E - E
. O N P F
0 3 6 USLI P .P O Y DI LD L
$ SITIS E D D YI N ! I E E ERW H O O OAO T A
A T N TA TC N NTN E C I M I W D UT L I L SIL I Y ARTR )1 EO NN D N LGL L X T EU I I O R D Se SITO EO .E Y YINY I R A E Eto WDEU B BPB P D T R N NN T M LF D MD P N C NUe HY I EAI DU E A U RI e T DETF E E N E N P N S D O T LA (S IRA EAI R S T WSE WEW I NDS WDC K HN . E ANTAL E.OCOILN O .EN E I E CA ANF GE T R EE EU EI N PR ROY LS U SA ADB g 'LO IT ESA#UOEOP HU FSNDN t N RN TLDIO RTNTE T SL I P OUE EI L L OO N I NC E DL LSE LE Y LA ER H T I E T EC E S T ~ y ISCL A EER ILTRSR CRC N A CUS P RTE V ALKE A RHTONAEA ATSRAP DP OM PUA L N ETR DU DCDI CL E . E EDR NR N CN L NRE L U HNNO A A t AOH S
) TAUCWL N At L L P Y
2
.I~.OLAT.W. .
F ( T 1 3 4 6 F E E C N D , E D I I S U E Y R Q R A I 8 D)5 N L 4 UE OT Y. DO R W E(N O H K 1F A L 1Y
.R p T TN O2A eN rU D
k L NI EO UP M FE LU L ' 4 1 f 3 E T uO F O. F ER W H O N . gB A E 0tH O i UC R FA OS A E UID cf j R $t j A . N j A j, o D L t E P
}Q u ~-d Y T ,
w C f - . H I O . R T
, p S
4 E [ R N / U 1 E I T / - O N 2 4 E T E O T N O N O O H2ROZtH Me ]. INN @O
l l
. CPS-0DCM r~T 2.3.2 Plant Service Water Effluent PRM Setpoints l '-i Plant service water effluent continuously releases to the Seal Well where it mixes with circulating water effluent (if present) prior to entering Lake Clinton via the 3.4 mile discharge flume. The plant service water effluent is not considered a radioactive discharge pathway unless liquid radwaste discharges are in progress or any service water - cooling load heat exchanger has been detected as failed. To ensure that Plant Service Water intersystem leakage has not occurred, weekly Service Water effluent grab samples will be obtained (when in service) and analyzed to determine the identity and quantity of principal gamma-emitting radionuclides. In addition, a quarterly composite of positive grab samples will be analyzed to determine the quantity of H-3, Sr-89, Sr-90, Fe-55 and gross alpha species released. The analytical Lower Limit of Detection (LLD) for these analyses are specified in CPS-RETS Table 4.11.1-1.A.
If the weekly grab sample analysis indicates the absence of contamination above background, the Plant Service Water effluent PRM setpoint should be established as close to background as practical to prevent spurious alarms, and yet assure an alarm should an inadvertent release occur. If the weekly grab sample analysis indicates the presenet of 9? contamination above background, PRM setpoints will be (~') (_/ established following section 2.3.1 methodology as follows: 2.3.2.1 Perform section 2.3.1.2, solving equation (3) for DF using the appropriate values in the concentration term from the grab sample analysis. 2.3.2.2 A modified dilution factor, DF ,m must be determined so that available dilution flows may be apportioned among simultaneous discharge pathways. The modified dilution factor is defined as: DF = DF (6) m p-A where F 4 is an administrative allocation factor which may be assigeta any value between 0 and 1 under the condition that CLINTON-I 2-7 Rev.3-12/87 f) V l
- -- - -- - - _ _ n
a,:n i c q c
-I CPS-0DCM
~p wy (FA )n j i (7) and where n = the number of liquid' discharge pathways for j
. which DF >l and which are planned for simultaneous release.
For simplicity, FA ma be assigned the value 1/n. Calculate F tank.in equation (4)yby substituting the value of DFm f r DF i and perform the calculation specified'in.section 2.3.1.4'to determine flow rate and PRM setpoints. [ , j 2.3.3 Shutdown Service Water (SX) Effluent PRM Setpoints Shutdown Service Water, when initiated, is a potential
;, continuous radioactive discharge pathway to the Ultimate Heat Sink (UHS).(see Figure 2.5-2). The SX effluent is not considered a radioactive discharge pathway unless any SX .i cooling load heat exchanger has been detected as failed. SX effluent sampling, analysis and setpoint establishment will' ,
be performed as discussed for the Plant Service Water system in section 2.3.2. 2.3.4 Fuel Pool Heat Exchanger Serv 1ce Water Effluent PRM Setpoints The Fuel Pool Heat Exchanger Service Water is normally supplied by the Component Cooling Water (CC) system (a. closed ..
"~
loop system). The CC system rejects heat loads to the Plant Service Water system where intersystem leakage would be detected as described'in section 2.3.2. The Fuel Pool Heat
~
Exchanger Service Water effluent is considered a potential radioactive discharge pathway when SX replaces CC as the heat To account for a
' potential sink for the fuelrelease batch pool heat of CC exchangers.'vity radioacti to the Ultimate Heat Sink via SX, CC will be sampled and analyzed as discussed in section 2.3.2. The analysis results will then be used to establish Fuel Pool Heat Exchanger Service Watdr PRM and flow rate setpoints following section 2.3.2.1 and 1 2.3.2.2 methodology.
Any releases of radioactivity to the environment from the Plant Service Water (except during liquid radwaste discharges), Shutdown Service Water or Fuel Fool Heat ' Exchanger' Service Water Systems are considered abnormal events. Such events will be accounted for as unplanned releases in the SEMIANNUAL RADI0 ACTIVE EFFLUENT RELEASE REPORT. t
, 1 CLINTON-I 2-8 Rev.2-10/86
CPS-0DCM I: 1 l .2. 4 10CFR50, Appendix I Release Rate Limits '/ ~, CPS RETS 3.11.1.2 requires that.the cumulative dose contributions to an individual from radioactive' material in i liquid effluents released to the unrestricted area be determined at least once per 31 days. The applicable dose limits'are: i 11.5 mrem / calendar -quarter - TOTAL BODYL l y 1 5.0 mrem / calendar quarter - ANY ORGAN ,1 l and ! L 1 3 mrem / calendar year - TOTAL BODY ! 1 10 mrem / calendar year - ANY ORGAN ' The dose contribution to the maximum exposed individual'from i all radionuclides identified in 'licuid effluents released to the unrestricted area is calculatec as follows:- m. D j=fAgj f 17J 4ty C ty F , mrem (8) D = The cumulative calendar quarter or yearly dose to 'l 3 any organ j from liquid effluent for the total release period, mrem (), At y = The length of the lth release time period over which' C11 and F1 are averaged for liquid releases, hours
= Liquid Radwaste Tank Volume / Liquid Radwaste Discharge Flow Rate i C
11
= The average concentration of nuclide i in undiluted liquid effluent during release period At l f r any liquid release, pC1/ml ,
1 F = The near field average dilution factor for C 7 duringanyliquideffluentrelease,dimensiobless. 3 Defined as the ratio of the average undiluted liquid l radwaste flow during the release, to the product of. i the average flow from the discharge structure j
.(during the reporting period, i.e., qusrter or year) l to the unrestricted receiving water and Z ! = Average Undiluted Liquid Waste Flow (9)
(Average Discharge Structure Flow) Z Z = The applicable dilution factor for Lake Clinton, j dimensionless i
= 1.0 1
() CLINTON-I 2-9 Rev.5-2/89 i
L l
. CPS-0DCM 1 1 I )
1
)~[L A = The composite ingestion dose commitment factor for f3 the' total body or critical organ of an ADULT for radionuclides i, mrem /hr per-uC1/ml , =K g Uw'+ UgBFt)DF t (10) w where .
K = A units conversion factor, 1.14E+05-pCi-ml-yr/pCi-liter-hr
= (1.0E+06 pCi/uCi)(1.0E+03 ml/ liter) 8760 hr/yr Uy = Annual water consumption by-the maximum adult, O.
liter /yr D" = Dilution factor from the near field area to the nearest potable water intake, 1.0
! U = Adult fish consumption rate, 21 kg/yr (Table E-5 of f
Regulatory Guide 1.109) BF = Bioaccumulation factor for radionuclides i in fish, 1 l pCi/kg per pC1/ liter (Table 2,4-2 taken from Table ;;; A-1 of Regulatory Guide 1.109)
- DF .i =Adultinfestiondoseconversion.factorfor radionuc ide i, total body or critical organ, mrem /pCi (Table 2.4-3 taken from Table E-11 of Regulatory Guide 1.109)
Table 2.4-1 contains values for A td as calculated by equation l (10). _. The quarterly limits referenced at the beginning of this section represent one-half of the annual design objective of Section II.A of 10CFR50, Appendix I. If either the calendar
. quarter or calendar year limits are exceeded, a special report pursuant to Section IV.A of 10CFR50, Appendix I shall be filed with the NRC.
1 I I O v CLINTON-I 2-10 Rev.1-11/85
CPS-0DCM I l i TABLE 2.4-1 73 Q ADULT INGESTION DOSE COMMITMENT FACTORS - A g (mrem /hr per pCi/ml) ISOTOPE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI H-3 NO DATA 2.26E-01 2.26E-01 2.26E-01 2.26E-01 2.26E-01 2.26E-01 C-14 3.12E+04* 6.24E+03 6.24E+03 6.24E+03 6.24E+03 6.24E+03 6.24E+03 NA-24 4.06E+02 4.06E+02 4.06E+02 4.06E+02 4.06E+02 4.06E+02 4.06E+02 P-32 1.39E+06 8.62E+04 5.36E+04 NO DATA NO DATA NO DATA 1.56E+05 CR-51 NO DATA NO DATA 1.27E+00 7.60E-01 2.80E-01 1.68E+00 3.20E+02 MN-54 NO DATA 4.37E+03 8.34E+02 NO DATA 1.30E+03 NO DATA 1.34E+04 MN-56 NO DATA 1.10E+02 1.95E+01 NO DATA 1.40E+02 NO DATA 3.51E+03 FE-55 6.57E+02 4.54E+02 1.06E+02 NO DATA NO DATA 2.53E+02 2.60E+02 FE-59 1.04E+03 2.44E+03 9.34E+02 NO DATA NO DATA 6.81E+02 8.13E+03 e CO-58 NO DATA 8.90E+01 2.00E+02 NO DATA NO DATA NO DATA 1,80E+03 CO-60 NO DATA 2.56E+02 5.64E+02 NO DATA NO DATA NO DATA 4.80E+03 NI-63 3.11E+04 2.15E+03 1.04E+03 NO DATA NO DATA NO DATA 4.49E+02 (3 V NI-65 1.26E+02 1.64E+01 7.48E+00 NO DATA NO DATA NO DATA 4.16E+02 CU-64 NO DATA 9.97E+00 4.67E+00 NO DATA 2.51E+01 NO DATA 8.48E+02 ZN-65 2.31E+04 7.36E+04 3.33E+04 NO DATA 4.92E+04 NO DATA 4.64E+04 ZN-69 4.92E+01 9.42E+01 6.55E+00 NO DATA 6.12E+01 NO DATA 1.41E+01 BR-83 NO DATA NO DATA 4.03E+01 NO DATA NO DATA NO DATA 5.81E+01 BR-84 NO DATA NO DATA 5.23E+01 NO DATA NO DATA NO DATA , 4.10E-04 l BR-85 NO DATA NO DATA 2.15E+00 NO DATA NO DATA NO DATA LT E-15** RB-86 NO DATA 1.01E+05 4.70E+04 NO DATA NO DATA NO DATA 1.99E+04 RB-88 NO DATA 2.89E+02 1.53E+02 NO DATA NO DATA NO DATA 4.00E-09 l RB-89 NO DATA 1.92E+02 1.35E+02 NO DATA NO DATA NO DATA 1.11E-11 SR-89 2.21E+04 NO DATA 6.34E+02 NO DATA NO DATA NO DATA 3.54E+03 SR-90 5.43E+05 NO DATA 1.33E+05 NO DATA NO DATA NO DATA 1.57E+04 l SR-91 4.06E+02 NO DATA 1.64E+01 NO DATA NO DATA NO DATA 1.94E+03 SR-92 1.54E402 NO DATA 6.67E+00 NO DATA NO DATA NO DATA 3.05E+03 Y-90 5.75E-01 NO DATA 1.54E-02 NO DATA NO DATA NO DATA 6.10E+03 l l CLINTON-I 2-11 Rev.5-2/89 I t _ _ - _ _ - - - _- - \
l CPS-0DCM
. TABLE 2.4-1 (continued)
O ^outr 1"ozsr on nose Cosa 18881 riCroas - ^13 l (mrem /hr per UCi/ml) l l ISOTOPE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI Y-91m 5.43E-03 NO DATA 2.10E-04 h0 DATA NO DATA NO DATA 1.60E-02 Y-91 8.42E+00 NO DATA 2.25E-01 NO DATA NO DATA NO DATA 4.64E+03 Y-92 5.05E-02 NO DATA 1.48E-03 NO DATA NO DATA NO DATA 8.84E+02 Y-93 1.60E-01 NO DATA 4.42E-03 NO DATA NO DATA NO DATA 5.08E+03 ZR-95 2.40E-01 7.69E-02 5.20E-02 NO DATA 1.21E-01 NO DATA 2.44E+02 ZR-97 1.32E-02 2.67E-03 1.22E-03 NO DATA 4.04E-03 NO DATA 8.28E+02 NB-95 4.46E+02 2.48E+02 1.33E+02 NO DATA 2.45E+02 NO DATA 1.51E+06 , MO-99 NO DATA 1.03E+02 1.96E+01 NO DATA 2.33E+02 NO DATA 2.39E+02 l TC-99m 8.86E-03 2.50E-02 3.19E-01 NO DATA 3.80E-01 1.23E-02 1.48E+01 . TC-101 9.1]E-03 1.31E-02 1.29E-01 NO DATA 2.36E-01 6.70E-03 3.94E-14 RU-103 4.42E%0 NO DATA 1.90E+00 NO DATA 1.69EM1 NO DATA 5.16E+02 RU-105 3.68E-01 NO DATA 1.45E-01 NO DATA 4.76E+00 NO DATA 2.25E+02 RU-106 6.57E+01 NO DATA 8.32E+00 NO DATA 1.27E+02 NO DATA 4.2SE+03 AG-110m NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA TE-125m 2.57E+03 9.28E+02 3.43E+02 7.70E+02 1.04E+04 NO DATA 1.02E+04 , i TE-127m 6.47E+03 2.31E+03 7.89E+02 1.65E+03 2.63E+04 NO DATA 2.17E+04 TE-127 1.05E+02 3.77E+01 2.28EM1 7.79E+01 4.28E+02 NO DATA 8.30E+03 TE-129m 1.10E+04 4.10E+03 1.74EM3 3.78EM3 4.59E+04 NO DATA , 5.54E+04 TE-129 3.00E+01 1.13E+01 7.31E+00 2.30E+01 1.26E+02 NO DATA 2.26E+01 TE-131m 1.65EM 3 8.09E+02 6.74EM2 1.28E+03 8.19E+03 NO DATA 8.03E+04 TE-131 1.88E+01 7.87E+00 5.95E+00 1.55E+01 8.25E+01 NO DATA 1.67E+00 TE-132 2.41E+03 1.56E+03 1.46E+03 1.72E+03 1.50E404 NO DATA 7.37E+04 I-130 2.71E+01 7.99E+01 3.15E+01 6.78E+03 1.25E+02 NO DATA 6.88E+01 1-131 1.49E+02 2.13E+02 1.22E+02 6.99E+04 3.66E+02 NO DATA 5.63E+01 I-132 7.28E+00 1.95E+01 6.81E%0 6.81E+02 3.10E+01 NO DATA 3.66E%0 I-133 5.09E+01 8.85EMI 2.70E+01 1.30EM4 1.54E+02 NO DATA 7.96E%1 I-134 3.80E+00 1.03E+01 3.69E+00 1.79E+02 1.64E+01 NO DATA 9.00E-03 O CLINTON-I 2-12 Rev.5-2/89
CPS-0DCM l 1 TABL8 2.4-1 (continued) ! O inutt nosst on noss coxa 1ratur ricroas - ^13 l (mrem /hr per uCi/ml) ISOTOPE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI I-135 1.59E+01 4.16E+01 1.53E+01 2.74E+03 6.67E+01 : 0 DATA 4.70E+01 CS-134 2.97E+05 '7.07E+05 5.78E+05 NO DATA 2.29E+05 7.60E+04 1.24E+04 CS-136 3.11E+04 1.23E+05 8.84E+04 NO DATA 6.84E+04 9.37E+03 1.40E+04 ! CS-137 3.81E+05 5.21E+05 3.41E+05 NO DATA 1.77E+05 5.88E+04 1.01E+04 ! CS-138 2.64E+02 5.21E+02 2.58E+02 NO DATA 3.83E+02 3.78E+01 2.22E-03 BA-139 9.29E-01 6.60E-04 2.72E-02 NO DATA 6.18E-04 3.75E-04 1.65E+00 BA-140 1.94E+02 2.44E-01 1.27E+01 NO DATA 8.29E-02 1.40E-01 4.00E+02 BA-141 4. DOE-01 3.40E-04 1.52E-02 NO DATA 3.16E-04 1.93E-04 2.12E-10 BA-142 2.04E-01 2.09E-04 1.28E-02 NO DATA 1.77E-04 1.18E-04 2.89E-19 LA-140 1.49E-01 7.53E-02 1.99E-02 NO DATA NO DATA NO DATA 5.53E+03 LA-142 7.65E-03 3.48E-03 8.66E-04 NO DATA NO DATA NO DATA 2.54E+01 CE-141 2.24E-02 1.51E-02 1.72E-03 NO DATA 7.03E-03 NO DATA 5.78E+01 O V CE-143 3.94E-03 2.92E+00 3.23E-04 NO DATA 1.28E-03 NO DATA 1.09E+02 CE-144 1.17E+00 4.88E-01 6.26E-02 NO DATA 2.89E-01 NO DATA 3.94E+02 PR-143 5.50E-01 2.20E-01 2.72E-02 NO DATA 1.27E-01 NO DATA 2.41E+03 PR-144 1.80E-03 7.47E-04 9.14E-05 NO DATA 4.21E-04 NO DATA 2.59E-10 ND-147 3.76E-01 4.34E-01 2.60E-02 NO DATA 2.54E-01 NO DATA 2.08E+03 W-187 2.95E+02 2.47E+02 8.63E+01 NO DATA NO DATA NO DATA 8.09E+04 NP-239 2.84E-02 2.80E-03 1.54E-03 NO DATA 8.72E-03 NO DATA 5.74E+02
- 4 3.12 x 10
** Less than 10-15 A
l U CLINTON-I 2-13 Rev.5-2/89
., _ = _ _ - _ _ _ _ 't ' CPS-ODCM L
l l i TABLE 2.4-2 E , i
,:t .BI0 ACCUMULATION FACTORS -BF g.
e (pCi/kg. per pCi/ liter) ..1 FRESHWATER' ELEMENT FISH H' 9.0E C 4.6E+03 NA 1.0E+02 P 3.0E+03 CR 2.0E+02 MN 4.0E+02 FE 1.0E+02' ) 5.0E+01 CO NI 1.0E+02 CU 5.0E+01 ZN 2.0E+03 BR 4.2E+02 RB 2.0E+03 SR 3.0E+01 Y 2.5E+01 ZR 3.3E+00 NB 3.0E+04 [ M0 1.0E+01 1.5E+01 TC RU l.0E+01 RH 1.0E+01 TE 4.0E+02 I .l.5E+01
. CS 2.0E+03-BA 4.0E+00 LA 2.5E+01 CE 1.0E+00 '
PR 2.5E+01 ND 2.5E+01 ] W l.2E+03 I NP 1.0E+01 l l l l O CLINTON-I 2-14 Rev.5-2/89 l
\
u CPS-0DCM l' l l 3 TABLE 2.4-3
'O ADULT INGESTION DOSE FACTORS -DF i l
l U (mrem /pCi ingested) l l l NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI , H-3 NO DATA 1.05E-07 1.05E-07 1.05E-07 1.05E-07 1.05E-07 1.05E-07 l C-14 2.84E-06* 5.68E-07 5.68E-07 5.68E-07 5.68E-07 5.68E-07 5.68E-07 NA-24 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 I P-32 1.93E-04 1.20E-05 7.46E-06 NO DATA NO DATA NO DATA 2.17E-05 > l CR-51 NO DATA NO DATA 2.66E-09 1.59E-09 5.86E-10 3.53E-09 6.69E-07 l MN-54 NO DATA 4.57E-06 8.72E-07 NO DATA 1.36E-06 NO : DATA 1.40E-05 1' MN-56 NO DATA 1.15E-07 2.04E-08 NO DATA 1.46E-07 NO DATA 3.67E-06 FE-55 2.75E-06 1.90E-06 4.43E-07 NO DATA NO DATA 1.06E-06 1.09E-06 FE-59 4.34E-06 1.02E-05 3.91E-06 NO DATA NO DATA 2.85E-06 3.40E-05 C0-58 NO DATA 7.45E-07 1.67E-06 NO DATA NO DATA NO DATA 1.51E-05 C0-60 NO DATA 2.14E-06 4.72E-06 NO DATA NO DATA NO DATA 4.02E-05 NI-63 1.30E-04 9.01E-06 4.36E-06 NO DATA NO DATA NO DATA 1.88E-06 NI-65 5.28E-07 6.86E-08 3.13E-08 NO DATA NO DATA NO DATA 1.74E-06 CU-64 NO DATA 8.33E-08 3.91E-08 NO DATA 2.10E-07 NO DATA 7.10E-06 ZN-65 4.84E-06 1.54E-05 6.96E-06 NO DATA 1.03E-05 NO DATA 9.70E-06 ZN-69 J.03E-08 1.97E-08 1.37E-09 NO DATA 1.28E-08 NO DATA 2.96E-09 BR-83 NO DATA NO DATA 4.02E-08 HO DATA NO DATA NO DATA 5.79E-08 BR-84 NO DATA NO DATA 5.21E-08 NO DATA NO DATA NO DATA 4.09E-13 BR-85 NO DATA NO DATA 2.14E-09 NO DATA NO DATA NO DATA LT E-24** RB-86 NO DATA 2.11E-05 9.83E-06 NO DATA NO DATA NO DATA 4.16E-06 RB-88 NO DATA 6.05E-08 3.21E-08 NO DATA NO DATA NO DATA 8.36E-19 { RB-89 NO DATA 4.01E-08 2.82E-08 NO DATA NO DATA NO DATA 2.33E-21 SR-89 3.08E-04 NO DATA 8.84E-06 NO DATA NO DATA NO DATA 4.94E-05 SR-90 7.58E-03 NO DATA 1.86E-03 NO DATA NO DATA NO DATA 2.19E-04 i k SR-91 5.67E-06 NO DATA 2.29E-07 NO DATA NO DATA NO DATA 2.70E-05 I SR-92 2.15E-06 NO DATA 9.30E-08 NO DATA NO DATA NO DATA 4.26E-05 ] Y-90 9.62E-09 NO DATA 2.58E-10 NO DATA NO DATA NO DATA 1.02E-04 j n V CLINTON-I 2-15 Rev.5-2/89 4 i l l
/
CPS-ODCM ,
'i
_ TABLE 2.4-3-(continued) ; h ADULT INGESTION DOSE FACTORS - DF f (mrem /pCi ingested) NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG CI-LLI
-Y-91m 9.09E-11 NO DATA 3.52E-12 NO DATA NO DATA NO DATA 2.67E-10 i Y-91 1.41E-07 NO DATA 3.77E-09 NO DATA NO DATA NO DATA 7.76E-05 Y-92 8.45E-10' NO DATA 2.47E-11 NO DATA NO DATA NO DATA 1.48E-05 Y-93 2.68E-09 NO DATA 7.40E-11 'NO DATA NO DATA NO DATA 8.50E-05 ZR-95 3.04E-08 9.75E-09 6.60E-09 NO DATA 1.53E-08 NO DATA 3.09E-05 ZR-97 1.68E-09 3.39E-10, 1.55E-10 NO DATA 5.12E NO DATA 1.05E-04 NB-95 6.22E-09 3.46E-09 1.86E-09 NO DATA 3.42E-09 NO DATA 2.10E-05 M0-99 NO DATA' 4.31E-06 8.20E-07 NO DATA 9.76E-06 NO DATA 9.99E-06 TC-99m 2.47E-10 6.98E-10 8.89E-09 NO DATA 1.06E-08 3.42E-10 4.13E TC-101 2.54E-10 3.66E-10 3.59E-09 NO DATA 6.59E-09 1.87E-10 1.10E-21 RU-103- 1.85E-07 NO DATA 7.97E-08 NO DATA 7.06E-07 NO DATA 2.16E RU-105 1.54E-08 NO DATA 6.08E-09 NO DATA 1.99E-07 NO DATA 9.42E-06 3.48E-07 5.31E-06 O RU-106 AG-110m TE-125m 2.75E-06 1.60E-07 2.68E-06 NO DATA 1.48E-07 9.71E-07 8.79E-08 3.59E-07 NO DATA NO DATA 8.06E-07 2.91E-07 1.09E-05 NO. DATA NO DATA NO DATA 1.78E-04 6.04E-05 1.07E-05 l
TE-127m 6.77E-06 2.42E-06 8.25E-07 1.73E-06 2.75E-05 NO DATA 2.27E-05 TE-127 1.10E-07 3.95E-08 2.38E-08 8.15E-08 4.48E-07 NO DATA 8.68E-06 j TE-129m 1.15E-05 4.29E-06 1.82E-06 3.95E-06 4.80E-05 NO DATA 5.79E-05 ! i TE-129 3.14E-08 1.18E-08 7.65E-09 2.41E-08 1.32E-07 NO DATA ' 2.37E-08 ' TE-131m 1.73E-06 8.46E-07 7.05E-07 1.34E-06 8.57E-06 NO DATA 8.40E-05 TE-131 1.97E-08 8.23E-09 6.22E-09 1.62E-08 8.63E-08 NO DATA 2.79E-09 TE-132 2.52E-06 1.63E-06 1.53E-06 1.80E-06 1.57E-05 NO DATA 7.71E-05 i I-130 7.56E-07 2.23E-06 8.80E-07 1.89E-04 3.48E-06 NO DATA 1.92E-06 ' I-131 4.16E-06 5.95E-06 3.41E-06 1.95E-03 1.02E-05 NO DATA 1.57E-06 )I 1-132 2.03E-07 5.43E-07 1.90E-07 1.90E-05 8.65E-07 NO DATA 1.02E-07 I-133' 1.42E-06 2.47E-06 7.53E-07 3.63E-04 4.31E-06 NO DATA 2.22E-06 I-134 1.06E-07 2.88E-07 1.03E-07 4.99E-06 4.58E-07 NO DATA 2.51E-10 1 O i CI.INTON-I 2-16 Rev.5-2/89
CPS-0DCM TABLE 2.4-3 (continued) I (n
'~') ADULT INGESTION DOSE FACTORS - DFi (mrem /pCi ingested)
NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI I-135 4.43E-07 1.16E-06 4.28E-07 7.65E-05 1.86E-06 NO DATA 1.31E-06 CS-134 6.22E-05 1.48E-04 1.21E-04 NO DATA 4.79E-05 1.59E-05 2.59E-06 CS-136 6.51E-06 2.57E-05 1.85E-05 NO DATA 1.43E-05 1.96E-06 2.92E-06 i CS-137 7.97E-05 1.09E-04 7.14E-05 NO DATA 3.70E-05 1.23E-05 2.11E-06 CS-138 5.52E-08 1.09E-07 5.40E-08 NO DATA 8.01E-08 7.91E-09 4.65E-13 BA-139 9.70E-08 6.91E-11 2.84E-09 NO DATA 6.46E-11 3.92E-11 1.72E-07 BA-140 2.03E-05 2.55E-08 1.33E-06 NO DATA 8.67E-09 1.46E-08 4.18E-05 BA-141 4.71E-08 3.56E-11 1.59E-09 NO DATA 3.31E-11 2.02E-11 2.22E-17 BA-142 2.13E-08 2.19E-11 1.34E-09 NO DATA 1.85E-11 1.24E-11 3.00E-26 LA-140 2.50E-09 1.26E-09 3.33E-10 NO DATA NO DATA NO DATA 9.25E-05 LA-142 1.28E-10 5.82E-11 1.45E-11 NO DATA NO DATA NO DATA 4.25E-07 CE-141 9.36E-09 6.33E-09 7.18E-10 NO DATA 2.94E-09 NO DATA 2.42E-05 CE-143 1.65E-09 1.22E-06 1.35E-10 NO DATA 5.37E-10 NO DATA 4.56E-05 CE-144 4.88E-07 2.04E-07 2.62E-08 NO DATA 1.21E-07 NO DATA 1.65E-04 PR-143 9.20E-09 3.69E-09 4.56E-10 NO DATA 2.13E-09 NO DATA 4.03E-05 PR-144 0.01E-11 1.25E-11 1.53E-12 NO DATA 7.05E-12 NO DATA 4.33E-18 ND-147 6.29E-09 7.27E-09 4.35E-10 NO DATA 4.25E-09 NO DATA 3.49E-05 W-187 1.03E-07 8.61E-08 3.01E-08 NO DATA NO DATA NO DATA 2.82E-05 NP-239 1.19E-09 1.17E-10 6.45E-11 NO DATA 3.65E-10 NO DATA 2.40E-05
- 2.84 X 10-06
** Less than 10-24 O
l CLINTON-I 2-17 Rev.5-2/89 i
1
-l FIGURE 2.5-1 O LIQUID RADWASTE TREATMENT SYSTEM G + --o<:
dk Jk {x ._ ,, j( OWE 0o g I p - *
;s o m oser . *- -t><: '
I:><: e.n. cY j[
% Tuth p,.,, w owcoire ')[ N oe , o wtoivo c u.c h -
M oge,,pe iwrots swro*r n n ,
~F + X x owcorre ****
- Rw cewcken owcoss owgotr owtose
)( )( -H H hsb ; 5M * , ,,3 *oenoe ; 'o*
zwr.ts 2w'o4 r a gro.m [ ][ p@ros s $ 4% u : bg cac% 5" Jeu Sedce
, M8" To 4 f h\r3(ng ' W.fer DNkage
- n o., e % br -
- Monitors required by CPS TECHNICAL SPECIFICATIONS .
I IWF01S Floor Drain OWZO1P Chem. Wst. 2WF04T Floor Drain 0WE02TA,B, and C Waste l l Evaporator Evap. Tank Pump Evaporator Tank Samp. Tk Pumps 2WF01S Floor Drain OVE01FA,B, and C OWZ01T Chem. Waste OWE 01TA and B Excess Evaporator Maste Filters Evaporator Tank Water Tanks { 1 OUZOIS Chemical OWE 01DA,B, and C IWF04P Fir. Drn. OWE 0lPA and B Excess Waste Evaporator Waste Demins Evap. Tank Pump Water Tank Pumps IWF04T Floor Drain 0WE02TA,B, and C 2WF04P Fir. Drn. IPR 036 Service Evaporator Tank Waste Sample Tks. Evap. Tank Pump Water PRM l l OPR040 Liquid RW Discharge PRM O CLINTON-I 2-18 Rev.5-2/89 l (
CPS-0DCM y FIGURE 2.5-2 SHUTDOWN AND FUEL POOL HEAT EXCHANGER SERVICE WATER EFFLUENT MONITORS tct
. 1RI A-FR004 I a WAfra grrtutNT "A" Slag WAf te f$ 1 EAT gagggggga og= ,,,
orven Systen intA raals e - LOADS b L_3
!EII.5" 4
- 1 EEin"*
HATER
, hATLA f~~1 L_J e UTMER SYSTEM , n'f"" .--
rgh:n,,, 3 .--,, na ::;;;a , a-- -r 9 ::;;;a g;ig..= .n g,,,, .
!!lnnJ'i . mt,st u, 1i '1;"n.r na u,t:+'""" =,30 ... ,
NORMAL COOLING SUPPLY - COMPONENT COOLING WATER EMERGENCY COOLING SUPPLY - SHUTDOWN SERVICE WATER
- Monitors required by CPS TECHNICAL SPECIFICATIONS 1PR038 Shutdown Service 1PR005 Fu'el Fool Heat
- Water Effluent "A" Exchanger Service Water PRM 1PR039 Shutdown Service IPR 004 Fuel Pool Hea t Water Effluent "B" Exchanger Service Water PRM f
7s , J CLINTON-I 2-19 Rev. 2-10/86
.v i
ob u t n e a3 mi n t a _' e r *C t1 - r o o L g L J mt J a J ofi C. s ni r d d n fe ev eo o e0 e pr n - S t V 5 g
- r C5 lu rylae r HD
%e v
e l C a cf t yd i5 r aw M Dar s MA ER TG SA YI 3 SD 5 EW TO y 5 i 2 SL
) ,k .e AF W T r D. D
_ u IE g RI i F
- F DI IL LP OM SI
- S te a
r r t to n t a r geg e f: 9 s e n . a p C s s i i = <i e % e s . n s c j p p ur a a u8 oA n s,u e ? 5 ,f 1 t WlS !8 Cvr m
- e r
e a n. r a. a-o'
- c. cr '
h s m o o vo"* ae tca Wc F e*
- neHZaaI. y - NINO yQ:<. YIN N g O.
- l
CPS-ODCM 2.5 Compliance WiGi CPS RETS 3.11.1.3/3.11.1.4 s l ('"') The projected doses due to releases of liquid .radwaste I effluents will be calculated using equation (8). If the sum i l of the accumulated dose to date for the month and the projected dose for the remainder of the month exceeds CPS RETS 3.11.1.3 limits, then the liquid radwaste treatment system shall be used. This is to ensure compliance with the OPERABILITY requirement of CPS RETS 3.11.1.3; Figure 2.5-1 shows the appropriate portions of the liquid radwaste treatment system which will be used. j The use of temporary liquid radwaste hold-up tanks may occur at CPS. To comply with CPS RETS 3.11.1.4, the amount of liquid ; radwaste stored in such tanks shall be limited to 10 curies, excluding tritium and dissolved or entrained noble gases. In lieu of the 10 curie limit, the methodology presented in ! Appendix B of NUREG-0133 (BWR-RATAFR code) will be used to ! establish the curie limit. I 2.6 Doses From Other Significant Liquid Effluent Pathways Section 2.4 of the CPS-0DCM describes demonstrating compliance with CPS RETS 3.11.1.2 based upon the aquatic food ; s.nd potable water exposure pathways only. Other exposure i (~T pathways, namely shoreline deposits and irrigated foods, may
\_/ arise at Clinton Power Station and will be included in the section 2.4 dose contribution if they are likely to provide a significant contribution to the total dose. A pathway is considered significant if a conservative evaluation yields an additional dose increment equal to or more than 10 percent of . the total from all other existing pathways. Methods for calculating doses from other potentially significant liquid effluent pathways are presented in Appendix A to Regulatory l Guide 1.109. .
When it is determined that other liquid effluent pathways do , I exist, the Regulatory Guide 1.109 Appendix A equations and parameters will be used in lieu of site-specific data to i determine a pathway's significance. l l l l 1 1 f~)#
- CLINTON-I 2-21 Rev.5-2/89 l
l
I CPS-ODCM O I TABLE 2.6-1. Input Parameters for Calculating R,p) l
~
t l i DELETED l L. i I l l
; ~
t 4 CLINTON-I 2-22 Rev.2-10/86
E ] ' ). l CPS-0DCM l a q
) ]' 3.0 GASEOUS EFFLUENTS 3.1 Introduction !
Gaseous effluents from CPS are released on both a batch and continuous basis. Gaseous effluents are l normally discharged on a long term basis. High volume Continuous Containment Purge and mechanical vacuum 3 pump discharge may be considered short term releases. l There are two gaseous effluent release points to the environment: the Common Station HVAC Stack and the Standby Gas Treatment System (SGTS) Stack. The height of t.hese stacks is such that all gaseous effluents are treated as mixed-mode releases (reference Table l 7.2-4). The SGTS is an Engineered Safety Feature , filter system utilized following an accident to reduce iodine and particulate activity in gases leaking from the primary containment and which are potentially present in the secondary containment. The Common Station HVAC Stack ("HVAC Stack") receives process and ventilation exhaust from the following inputs:
- 1) Continuous Containment Purge (CCP)
- 2) Containment Building Ventilation ;;p
- 3) Turbine Building Ventilation
- 4) Radwaste Building Ventilation 9*-
5) 6) 7) Auxiliary Building Ventilation Fuel Building Ventilation Auxiliary Building Refrigerant Purge
- 8) Laboratory Ventilation System
- 9) Counting / Equipment Decon Rooms Ventilation
- 10) Steam Packing Exhauster ~
- 11) Mechanical Vacuum Pump
- 12) Drywell Purge l The effluent exiting the SGTS stack is monitored at the SGTS stack and the combined inputs to the HVAC l
stack are monitored at the HVAC stack. All inputs to l j the HVAC Stack, with the exception of input numbers 7 i through 10, can be monitored prior to entering the stack. Figure 3.1-1 delineates the CPS site boundary for implementation of the gaseous effluent CPS RETS. l f% (Il 3 CLINTON-1 3-1 Rev.2-10/86
i l CPS-0DCM 3.2 Gaseous Effluent Release Point Monitoring 3.2.1 HVAC Stack Process Radiation Monitoring (PRM) System The HVAC Stack inputs are monitored for radioactivity prior to discharge to the environment by the HVAC Stack PRM. The PRM detector configuration provides effluent monitoring using seven (7) channels as
! follows:
- 1) Beta scintillator for particulate
- 2) Alpha surface barrier detector to
; account for the radon / thoron contribution to the beta particulate measurement l 3) Gamma scintillator for iodine
- 4) Iodine background subtraction
- 5) Beta scintillator for low range noble - , , ,
gas e-9 6) Energy-compensated Geiger-Mueller (G-M) detector for high range noble gas
- 7) Energy-compensated G-M detector for gamma area subtraction This monitor has no control function but annunciated in'the Main Control Room.and the Radiation Protection Office where
- proper response actions will be initiated in accordance with CPS procedures.
3.2.2 SGTS Stack Process Radiation Monitoring (PRM) f Syctem l As discussed in section 3.1, the SGTS is used to reduce post-accident concentrations of radioactivity in the primary and secondary containment via filter trains. The SGTS Stack r l PRM monitors the gaseous effluent of the filter trains at the SGTS Stack prior to release to the environment. The PRM detector configuration utilizes six (6) - channels as follows:
/-
- 1) Beta scintillator for particulate
) /
CLINTON-I 3-2 Rev.1-11/85
l l CPS-0DCM 1
- 2) Gamma scintillator for iodine .
- 3) Iodine background subtraction
- 4) Beta scintillator for low range noble gas i
l 5) Energy-compensated G-M detector for intermediate range noble gas i i 6) Energy-compensated G-M detector for j gamma area subtraction
. This monitor has no control function but
- annunc.iates in the Main Control Room and i the Radiation Protection Office where
{ proper response actions will be initiated in accordance with CPS i procedures, i 3.3 Main Condenser Off-Gas Monitoring System i Pre-Treatment Air Ejector Off-Gas Process , 3.3.1 Radiation Monitor (PRM) 4 The Pre-Treatment Off-Gas PRM monitors hydrogen recombiner effluent Ior gross noble gas radioactivity. This effluent is then routed to the charcoal adsorbers for eventual release to thb environment via the station HVAC Stack (see. Figure 3.3-1). The PRM l detector configuration consists of a single energy-compensated G-M detector mounted in a gas volume. _ The monitor has no control function but annunciated in the Main Control Room and the Radiation Protection Office where proper response actions will be initiated in ac'cordance with CPS procedures. l i
]
t' CLINTON-I 3-3 Rev.2-10/86
3e , ,, CPS-0DCM ((
;' ., 3.3.2' Post-Treatment Air Ejector Off-Gas Process '- Radiation Monitor (PRM) -{
The Post-Treatment Off-Gas PRM monitors the Le gaseous radioactivity at upstream, , intermediate or. downstream sections'of the charcoal adsorber beds prior to the effluent entering the station HVAC Stack for release to the environment (see Figure 3,.3-1). The PRM . l-detector configuration'is as described for the i HVAC Stack PRM-(section 3.2.1). 1 The, monitor has two control functions. ! Upon detection of' noble gas activity in l excess of the' ALERT setpoint, the charcoal adsorber bypass valves shut (if in the ; charcoal bypass mode) and the'off-gas is t-routed through the adsorbers. , A
,f Should noble gas activity exceed the HIGH :
setpoint, or upon PRM failure, the off-gas .! system is automatically isolated from the-HVAC 1 j Stack and a reactor scram may occur if loss of, e condenser vacuum occurs, n The Main Condenser Off-Gas Treatment System is j shown.in Figure:3.3-1. tj 3.4' 10CFR20 Release Rate' Limits 1 {- 2 Limits for release of airborne effluents to the i unrestricted area are stated in CPS RETS 3.11.2.1. ] The dose rate in unrestricted areas due to radioactive materials released in gaseous effluents from the site- ~ 1 shall be limited to the following values: j (a) Noble Gases - < 500 mrem / year to the total body
'} and 1
3 3000 mrem / year to the skin (b) Radioiodines, I. Particulate and Tritium - 11500 mrem / year to any.
! organ i
CLINTON-I 3-4 Rev.2-10/86 m . _j
'CPSLODCM' 3.4.1 . Dose Rate-Due To Noble Gases ~'c (d
In order.to comply with CPS RETS 3.'ll.2.l(a), the dose rate'at or beyond the. site: boundary due to noble gases shall be calculated as follows: D t "E iiK II IU)mkiml -(1)
= total body dose rate at time of '
release, mrem / year D, =r g(Lg+1.1Mg)[(X7Q),Qg ,] (2)
= skin dose rate at time of release, mrem / year The terms in the above equations are defined 'in section 3.4.2.
3.4.2 Dose Rate Due To Radiciodines, Particulate and Tritium In order to comply with CPS RETS 3.ll.2.1(b), organ dose rates due to radiciodines (I-131, I-133), particulate with half-lives > 8 days and tritium'shall be calculated as follows: (:) D g =I ggj(X7Q),hg, P (3)
= organ dose rate at time of
- release, mrem /yr 1
l The terms used in equations (1) through (3) 1 l are defined as follows: K g'= The total body dose factor due to gamma emissions for each L identified noble gas radionuclides i, mrem /yr per pC1/m3 i ' Lt= The skin dose factor due to beta emissions for each identified noble gas radionuclides i, mrem /yr per pCi/m3 M y= The air dose factor due to gamma emissions for each identified noble gas radionuclides i, mrad /yr per pC1/m3 (1.1 mrem / mrad converts air dose to skin dose) 1 CLINTON-I 3-5 Rev.5-2/89 L. . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
D q 4 i 0 L
' CPS-ObCM .hsns /
1 P =, The dose factor'for non-noble gas f3' radionuclides.i and organ j which u includes pathway transport parameters, receptor usage factors and the dosimetry;of the
+ exposure. The dose factors'for the inhalation, mrem /yr.pe'r pCi/m3, pathway are'11sted in Table 3.4-2 (CHILD). Dose.
factors are based on NUREG-0133,_
! Section 5.2.1.1 assumptions l' unless otherwise stated.
I-The release rate of noble gas Q*=1 radionuclides i in gaseous effluent.from mixed-mode release points, UCi/sec i Qg* = The release rate of non-noble gas radionuclides 1 in gaseous effluent from mixed-mode release
< points, UCi/sec
(%7Q)* = The highest calculated annual __ average relative concentration * * " for any area at or beyond the site boundary from mixed-mode releases, sec/m3
'I ..
D is calculated for each of six organs and the total body: the m8ximum gD value is then used to determine compliance with CPS RETS-3.11.2.1(b). t i
.i 1
O CLINTON-I 3-6 Rev.2-10/86 _ ------ _ _ - - - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . _ _ _ _ _ _ . _ _ _ _ J
~
l CPS-0DCM ,~ x j The factors K , L ., and M relate,the l 1 t 1 radionuclides airborne concentrations to ! various dose rates assuming a semi-infinite cloud. These factors are listed , Table 3.4-1 and were obtained from Table ( B-1 of Regulatory Guide 1.109 after multiplying the values by the conversion 6 10 pCi/pC1. - 10CFR20 organ dose rate calculations are limited to the inhalation pathway only. l CPS RETS 3.11.2.1(a) is applicable to the unrestricted area. location characterized by the (%7Q) ,value which results in the maximum total body or skin dose commitment. Should the totel body and skin locations differ, the selected location shall be that which minimizes allowable release rates. Therefore, the dispersion values used in the equations for the implementation of CPS RETS 3.11.2.1 are maximum annual average values resulting from mixed-mcde releases. Table ;d 7.2-5 lists site boundary dispersion parameters for implementing CPS RETS 3.11.2.1. There are unrestricted areas within the CPS site boundary which are utilized by members of the public for residences, i farming, recreation and camping. Annual doses to members of the public at controlling unrestricted area locations-were calculated using section 3.4 methodology, occupancy factors and FSAR Table 11.3-9 gaseous source term. .The dispersion value (ODCM Table 7.2-1) selected for each controlling location was that which results in the maximum annual dose to a member of the public. Dose calculation results for these unrestricted areas are summarized in Table 3.4 3. Table 3.4-3 will be revised to remain consistent with the most recent land use census, updated dispersion values and gaseous source term. 1 (h b:
! CLINTON-I 3-7 Rev.1-11/85
_h ) 3 m
/
i r Cp o 3 3 4 3 4 3 3 3 3 2 3 4 3 3 rt ic r 0
+ +0 0 0 + +0 +0 0 0 0+ 0 0 + +04 + 0 0 Aa e E E E+ E E E +E E+ E E+ E E E E F ip 7 9 59 30 39 60 381 18 45 09 36 47 2 5 8 a
t es Bo e" / r y 1 1 1 2 1 7 1 1 1 7 2 1 4 3 7 2 D d a , r ' ( m
)
3
/
m i Cp ro r 3 0 1 0 30 40 40 40 20 20+ 20 30 30 30 30 30
- it r 4 + + +
S Ac a e E E E E E+ E+ E E+ E+ E+ E+ ]E+ 0E+ R p 3 2 7 2 3 3 6 E+ 7 3 6 2 1 E I aF m i r 2 7 1 5 7 6 5 2 5 3 9 5 2 3 E ne y l 1 6 1 1 1 1 3 3 3 1 1 9 9 _ G as / U Go d
, A D a r
D m _. ( D N A S ) 1 E 3 _ - S 4 A r m pJ 3 E G L E o t c a
/
i Cp 3 3 3 3 4 3 2 2 - 2 2 3 4 3 3 . L B F 0 0 0 + +0 + 0 0 0 0 0 0 0 0 + +0 0 _.Q B A O N e r e + s ip 6 4 E3 7E+ 1E 9E 6E 4 6E+l E+ 6 2 E+ E+ E+ E+ E E 3 9 E+ T o L 8 2 1 6 _ R D r 4 3 7 3 0 2 7 9 0 l. M y 1 1 9 2 1 7 4 9 3 7 1 1 4 2 n / m S i e R k r D S I ( m C
. A F
E ) S 3 O D / m i r C yo p 3 I 3 4 4 4 1 2 2 3 3 3 3 3 0 0 0 0+ 0 0+ 0+ 0+ 0 + 0 0 dt oc r e E 0 M0
+ + + + +
Ba E E E E+ E+ E E+ E E E E E E F p 7 1 2 7 6 6 5 1 4 2 1 2 3 4 l ae i r 1 6 9 4 6 5 1 5 9 1 8 4 8 8 t s oo / y 1 1 5 1 1 1 9 2 2 3 1 1 8 8 TD n - e r ( m e 1m3m3 5 5 7 8 d m i _ l c 5m 8 85 7 8 8 89 90 13 13 13 13 13 13 13 41 8 u - - - - - - O n i o Kr Kr Kr r r r K K K X X X Xe e e e X e Xe X e A r d a R 0gz$?H { ?4. 7 l
CPS-ODCM TABLE 3.4-2 INHALATION PATHWAY DOSE RATE FACTORS (CHILD) -P g (mrem /yr per yCi/m3) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE H-3 NO DATA 1.12E+03* 1.12E+03 1.12E+03 1.12E+03 1.12EM3 1.12E+03 C-14 3.59E+04 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 NA-24 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 P-32 2.60E+06 1.14E+05 9.88E+04 NO DATA NO DATA NO DATA 4.22E+04 CR-51 NO DATA NO DATA 1.54E+02 8.55E+01 2.43+01 1.70E+04 1.08E+03 MN-54 NO DATA 4.29E-04 9.51E+03 NO DATA 1.00E+04 1.58EM 6 2.29E+04 MN-56 NO DATA 1.66E+00 3.12E-01 NO DATA 1.67E+00 1.31E+04 1.23E+05 FE-55 4.74E+04 2.52E+04 7.77E+03 NO DATA NO DATA 1.11E+05 2.87E+03 FE-59 2.07E+04 3.34E+04 1.67E+04 NO DATA NO DATA 1.27E+06 7.07E+04 j CO-58 NO DATA 1.77E+03 3.16E+03 NO DATA NO DATA 1.11E+06 3.44E+04 CO-60 NO DATA 1.31E+04 2.26E+04 NO DATA NO DATA 7.07E+06 9.62E+04 NI-63 8.21E+05 4.63E+04 2.80E+04 NO DATA NO DATA 2.75EM5 6.33E+03 { O NI-65 2.99E+00 2.96E-01 1.64E-01 NO DATA NO DATA 8.18E+03 8.40E+04 CU-64 NO DATA 1.99E+00 1.07E+00 NO DATA 6.03E+00 9.58E+03 3.67EM4 j ZN-65 4.26E+04 1.13E+05 7.03E+04 NO DATA 7.14E+04 9.95E+05 1.63E+04 l I ZN-69 6.70E-02 9.66E-02 8.92E-03 NO DATA 5.85E-02 1.42E+03 1.02E+04 j BR-83 NO DATA NO DATA 4.74E+02 NO DATA NO DATA NO DATA LT 3.70E-15** ' BR-84 NO DATA NO DATA 5.48E+02 NO DATA NO DATA NO DATA , LT 3.70E-15 l BR-85 NO DATA NO DATA 2.53E+01 NO DATA NO DATA NO DATA LT 3.70E-15 RB-86 NO DATA 1.98E+05 1.14E+05 NO DATA NO DATA NO DATA 7.99E+03 RB-88 NO DATA 5.62E+02 3.66E+02 NO DATA NO DATA NO DATA 1.72E+01 RB-89 NO DATA 3.45E+02 2.90E+02 NO DATA NO DATA NO DATA 1.89E+00 SR-89 5.99E+05 NO DATA 1.72E+04 NO DATA NO DATA 2.16E+06 1.67E+05 SR-90 1.01E+08 NO DATA 6.49E+06 NO DATA NO DATA 1.48E+07 3.43E+05 l \ l SR-91 1.21E+02 NO DATA 4.59EMO NO DATA NO DATA 5.33E+04 1.74E45 SR-92 1.31E+01 NO DATA 5.25E-01 NO DATA NO DATA 2.40E+04 2.42E+05 Y-90 4.11EM3 NO DATA 1.11E+02 NO DATA NO DATA 2.62E+05 2.68E+05 O CLINTON-I 3-9 Rev.5-2/89 l , b -- _ _ _ _ _ _ _ _ _ _ _ _ . - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ ____.. ____
CPS-0DCM TABLE 3.4-2 (cont'd) INHALATION PATHWAY DOSE RATE FACTORS (CHILD) -P
!] \ (mrem /yr per pCi/m3) id ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE Y-91m 5.07E-01 NO DATA 1.84E-02 NO DATA NO DATA 2.81E+03 1.72+03 Y-91 9.14E+05 NO DATA 2.44E+04 NO DATA NO DATA 2.63+06 1.84E+05 Y-92 2.04E+01 NO DATA 5.81E-01 NO DATA NO DATA 2.39E+04 2.39E+05 l ~
Y-93 1.87E+02 NO DATA 5.11E+00 NO DATA NO DATA 7.44E+04 3.89E+05 ZR-95 1.90E+05 4.18E+04 3.70E+04 NO DATA 5.96E+04 2.23E+06 6.11E+04 ZR-97 1.88E+02 2.72E+01 1.60E+01 NO DATA 3.89E+01 1.13E+05 3.51EH)5 I NB-95 2.35E+04 9.18EM3 6.55E+03 NO DATA 8.62E+03 6.14E+05 3.70E+04 ! MO-99 NO DATA 1.72E+02 4.26E+01 NO DATA 3.92E+02 1.35E+05 1.27E+05 ! TC-99m 1.78E-03 3.48E-03 5.77E-02 NO DATA 5.07E-02 9.51E+02 4.81E+03 TC-101 8.10E-05 8.51E-05 1.08E-03 NO DATA 1.45E-03 5.82E+02 1.63E+01 RU-103 2.79E+03 NO DATA 1.07E+03 NO DATA 7.03E+03 6.62E+05 4.48E+04 RU-105 1.53E+00 NO DATA 5.55E-01 NO DATA 1.34E+0D 1.59E+04 9.95E+04 A b RU-106 1.36E+05 NO DATA 1.69E+04 NO DATA 1.84E+05 1.43E+07 4.29E+05 AG-110m 1.69E+04 1.14E+04 9.14E+03 NO DATA 2.12E+04 5.48E+06 1.00E+05 TE-125m 6.73E+03 2.33E+03 9.14E+02 1.92E+03 NO DATA 4.77E+05 3.38E+04 TE-127m 2.49E+04 8.56E+03 3.03E+03 6.07E+03 6.36E+04 1.48E+06 7.14E+04 TE-127 2.77E+00 9.51E-01 6.11E-01 1.96E+00 7.07E+00 1.00E+04 5.62E+04 TE-129m 1.92E+04 6.85E+03 3.04E+03 6.33E+03 5.03E+04 1.76E+06 1.82E+05 j TE-129 9.77E-02 3.50E-02 2.38E-02 7.14E-02 2.57E-01 2.93E+03 2.55E+04 TE-131m 1.34E+02 5.92E+01 5.07E+01 9.77E+01 4.00E+02 2.06E+05 3.08E+05 TE-131 2.17E-02 8.44E-03 6.59E-03 1.70E-03 5.88E-02 2.05E+03 1.33E+03 TE-132 4.81E+02 2.72E+02 2.63E+02 3.18EM2 1.77E+03 3.77E+05 1.38E+05 I-130 8.18E+03 1.64E+04 8.44E+03 1.85E+06 2.45E+04 NO DATA 5.11E+03 I-131 4.81E+04 4.81E+04 2.73EM4 1.62E+07 7.88E+04 NO DATA 2.84E+03 1 I-132 2.12E+03 4.07E+03 1.88E+03 1.94E+05 6.25EM 3 NO DATA 3.20E+03 I-133 1.66E+04 2.03E+04 7.70E+03 3.85E+06 3.38E+04 NO DATA 5.48E+03 I-134 1.17E%3 2.16E+03 9.95E+02 5.07E+04 3.30E+03 NO DATA 9.55E+02 O v CLINTON-I 3-10 Rev.5-2/89
l CPS-0DCM s
)
i TABLE 3.4-2 (cont'd)
' INHALATION PATHWAY DOSE RATE FACTORS (CHILD) -P (mrem /yr per pCi/m3) id ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE I-135 4.92E+03 8.73E+03 4.14E+03 7. 92E405 1.34E+04 NO DATA 4.44E+03 CS-134 6.51E+05 1.01E+06 2.25E+05 NO DATA 3.30E+05 1.21E+05 3.84E+03 CS-136 6.51E+04 1.71E+05 1.16E+05 NO DATA 9.55E+04 1.45E+04 4.18E+03 i
CS-137 9.07E+05 8.25E+05 1.28E+05 NO DATA 2.82E+05 1.04E+05 3.62E+03
} 5.55E+02 NO DATA 6.21E+02 6.81E+01 2.70E+02 CS-138 6.33E+02 8.40E+02 I, BA-139 1.84E+00 9.84E-04 5.37E-02 NO DATA 8.62E-04 5.77E+03 5.77E+04 l
BA-140 7.40E+04 6.48E+01 4.33E+03 NO DATA 2.11E+01 1.74E+06 1.02E+05 j RA-141 1.96E-01 1.09E-04 6.36E-03 NO DATA 9.47E-05 2.92E+03 2.75E+02 BA-142 5.00E-02 3.60E-05 2.79E-03 NO DATA 2.91E-05 1.64E+03 2.74E+00 I LA-140 6.44E+02 2.25E+02 7.55E+01 NO DATA NO DATA 1.83E+05 2.26E+05
~LA-142 1.'30E+00 4.11E-01 1.29E-01 NO DATA NO DATA 8.70E+03 7.59E+04 CE-141 3.92E+04 1.95E+04 2.90E+03 NO DATA 8.55E+03 5.44E+05 5.66E+04 CE-143 3.66E+02 1.99E+02 2.88E+01 NO DATA 8.36E+01 1.15E+05 1.27E+05 CE-144 6.77E+06 2.12E+06 3.62E+05 NO DATA 1.17E+06 1.20E+07 3.89E+05 PR-143 1.85E+04 5.55E+03 9.14E+02 NO DATA 3.00E+03 4.33E+05 9.73E+04 y -.
PR-144 5.96E-02 1.85E-02 3.00E-03 NO DATA 9.77E-03 1.57E+03 1.97E+02 l 4.81E+03 3.28E+05 8.21E+04 ND-147 1.08E+04 8.73E+03 6.81E+02 NO DATA l W-187 1.63E+01 9.66E+00 4.33E+00 NO DATA NO DATA 4.11E+04 9.10E+04 i NP-239 4.66E+02 3.35E+01 2.35E+01 NO DATA 9.73E+01 5.81E+04 6.40E+04
*1.12 x 10' -15 **Less than 3.70 x 10 i .
i i k. I \ LA CLINTON-I 3-11 Rev.2-10/86
CPS-0DCM l
' 'i TABLE 3.4-3 -J l 1
ANNUAL DOSES IN UNRESTRICTED AREAS l i Total Body Skin Organ l Distance Occupancy Dose Rate Dose Rate Dose Rate
- Location (mile / meter) Sector (hrs /yr) (mrem /yr) (mrem /yr) (mrem /yr)
Road 0.3/495 SE 243(1) 0.04 0.08 0.02 Agricultural Acreage (2) 0.9/1372 SSW 964(3) 0.02 0.05 0.01 Clinton Lake 0.2/335 NW 2208(4) 1.0 2.1 0.51 Department of Conservation Recreation Area 0.8/1287 ESE 2208(5) 0.1 0.2 0.05 Residence 0.8/1219 SW 8760 0.5 1.0 0.24 Residence 1.5/2414 WSW 8760 0.2 0.4 0.10 Residence 1.7/2736 SSE 8760 0.1 0.2 0.05 iM (1) Assumes travel on road for forty minutes per day. (2) Maximum farm acreage (276) within site boundary. (3) Assumes 3.5 hours in field per acre farmed. (4) Assumes continuous occupation on Clinton Lake for the months of June, July, and August. (5) Assumes continuous occupation on Department of Conservation camping areas for the months of June, July, and August.
- Child inhalation r~N l
! 'h CLINTON-I
/
3-12 Rev.4-10/88
4 P' 1 CPS-0DCM
,-q I
Ny- 3.5 10CFR50, APPENDIX I RELEASE RATE LIMITS
.}
The requirements pertaining to 10CFR50 gaseous release rate limits are stated in CPS RETS 3.11.2.2 and 3.11.2.3. CPS RETS 3.ll.2.2 requires that the air dose at or beyond the site boundary,-due to noble Iases, shall be limited to the following: (a) During any calendar quarter, <5 mrad (gamma) and .510 mrad (bet'a) and, (b) During any calendar year, 510 mrad (gamma)' and_f20 mrad (beta). CPS RETS 3.11.2.3 requires that the dose to an individual at or beyond the site boundary, due to. radioiodines (I-131, I-133), tritium and all particulate with half-lives >8 days, shall be limited to the following: (a) During any calendar quarter, 17.5 mrem to any organ and, - (b) During any calendar year, 315 mrem to any organ. ;; 3.5.1 Noble Gas Air Dose The air dose at or beyond the site boundary due to noble gases released in gaseous effluent will be determined using the following equations. 3.5.1.1 During any calendar quarter or calendar - year, for gamma radiation: Dj = 3.17 x 10-8. kg ggy7q)m 91m + (4) (x/q) ,q1,] . l 3.5.1.2 During any calendar quarter or calendar year, for beta radiation: Dg = 3.17 x 10-8 N1 [(X7Q),Q t ,+ l (x/q) ,q1,] (5) Where M1 = The gamma air dose factor for , each identified noble gas radionuclides 1, mrad / year per pCi/m3 (M values are listed in 1 Table 3.4-1), Oe l CLINTON-I 3-13 Rev.2-10/86
, . CPS-0DCM- ]
N1= The beta air dose factor for each' n identified noble gas radionuclides
'() '- 1, mrad / year per pCi/m3 (N g 1 values are listed in Table i 3.4-1). !
l
', (XTQ)* ='The highest calculated annual i average relative concentration 'from mixed-mode release aoints for areas at or beyond tae site boundary for long-term (> 500 l hrs /yr)-releases, sec/m3 (x/q)* = The relative concentration from mixed-mode release' points for areas at or beyond the site i boundary for short-term (< 500 hrs /yr not to exceed 150 lirs/qtr) :
releases, sec/m3 ) Q*= t The average release of noble' gas radionuclides i for long-term releases from mixed-mode release. points, pCi. Releases shall be cumulative over the calendar quarter or year, as appropriate. p q1,= The average release of noble gas O radionuclides i for short-term releases from mixed-mode release points, pC1. Releases shall be cumulative over the calendar quarter or year, as appropriate. 3.17 x 10-8 = The inverse of the number of seconds in a year. f l O CLINTON-I 3-14 Rev.5-2/89
l y l CPS-0DCM CPS.RETS 3.11.2.2 noble gas dose
) calculations are evaluated at the site boundary location where maximum annual average air. doses prevail. Should the .;- beta and gamma locations differ, the i selected location shall be that which minimizes. allowable release rates due to the gamma component. Therefore, the .; dispersion values used in the equations i for the implementation of; CPS RETS 3.11.2.2 (long-term releases) are maximum annual average values resulting from mixed-mode releases.
For releases which occur less than 150 hours in any quarter not to exceed 500-hours in a calendar year,.short term dispersion values will be used by calculating a short term correction factor i ( , as discussed in NUREG-0324 (reference section 7.3.12). The'short-term diffusion estimates (5% X/Q) listed in FSAR Table 2.3-42 may also be used. When past short-term releases are determined to be l sufficiently random in occurence to be ;; represented by annual average dispersion conditions,-such data will be used.
- Table 7.2-5 lists site boundary dispersion parameters for implementing CPS RETS i 3.11.2.2.
p 3.5.2 Radioiodines, Particulate and Tritium Dose _ The dose to an individual at or beyond the. site boundary due to radioiodines (1-131, I-133), tritium and particulate with half-lives >8 days, will be determined using the following equation: j for any calendar quarter or calendar year, o D = 3.17 x 10~8[tR ag) [W,ki ,+ w,kg,] (6)
; p where l The releases of radionuclides i h"=
I (I-131, I-133, tritium and particulate) for long-term ( >500 hrs /yr) releases irom mixed-mode release points, pCi. Releases j g shall be cumulative over the ] (-'g , calendar quarter or year, as appropriate. I CLINTON-I 3-15 Rev.1-11/85
CPS-0DCM - I 1 i q1" = The releases of radionuclides i
~'
s) (I-131, I-133, tritium and , particulate) for short-term i (< 500 hrs /yr not to exceed 150 ; hrs /qtr) releases from mixed-mode I release points,yCi. Releases shall be cumulative over the i calendar quarter or year, as appropriate. (U7Q)* = The relative deposition from 4 mixed-mode release points for I areas at or beyond the site I boundary (> 500 hrsfor lonI"e-term
/yr) re ases, m-2 .
l (d/q)* = The relative deposition from ; mixed-mode release points for i areas at or beyond the site ; boundary for short-term (< 500 hrs /yr not to eyceed 150 hrs /qtr) releases, m~ W*.= The dispersion parameter for estimating the dose to an ('~3 individual at a controlling (/ location for long-term mixed-mode releases. (X7Q) , sec/m3, for the inhal3 tion. pathway y
~ =
(U7Q),, m *, for the food and ground plane pathways i w* = The dispersion parameter for estimating the dose to an i individual at a controlling ! location for short-term mixed-mode releases.
- (x/q) , sec/m 3 , for the inha19 tion pathway (d/q),, m
- for the food and ground plane pathways
( i CLINTON-I 3-16 Rev.5-2/89 u_____-______.
i K CPS-0DCM
- [~}
) 3.17 x'10~8 = The inverse of.the number of seconds in a year. . j L 1 Raij = The dose factor for each !
[ identified radionuclides i, age group (a) and organ j, m -mrem / year per pCi/sec or mrem / year per'pCi/m3 i CPS RETS 3.11.2.3. is applicable to the ! location at or beyond the site boundary I where the combination of existing pathways I
' and receptor age groups indicates the !
maximum potential exposure. The f inhalation and ground plane exposure l pathways exist at all locations: other , pathways exist as determined by the most current land use census, j j Table 7.2-5 lists site boundary dispersion 9 j and deposition parameters for implementing ! CPS RETS 3.11.2.3 3.5.2.1 Dose Tactor For Radionuclides 1 (R,(j) ,,,,,, e: The R aij values used to calculate D p in 4 equation (6) are determined separately for each of the potential exposure pathways,
~
namely:
- Inhalation (I)
- Ground Plane Contamination (G)
'
- Grass-Cow / Goat-Milk (C) ~'
- Grass-Cow-Meat (M) 1
' Vegetation (V) j The R 313 parameter is independent of the duration of gaseous releases and'is calculated using the methodology discussed in the remainder of this section. ;
1 l l j - Q CLINTON-I 3-17 Rev.1-11/85 8
\ P i
i l CPS-0DCM
- f. f') '
L - (/ ' L 3.5.2.1.1 Calculationiof the Inhalation- .
) '
PathwayFactor,'Rf13 Rft)=K'(BR),(DFA)a' 1 mrem /yearper Ci/m3'(7) where K' = A units conversion constant, 10 6 pCi/pi The breathing rate of'the (BR)a= receptor age group (a), m / year. S
= 1400 (infant) = 3700 (child) = 8000 (teen and adult)
Values for (BR)a are obtained from-NUREG-0133, p.32. I (DFA f ),= The organ inhalation dose factor for receptor of age group.(a) for radionuclides i, mrem /pC1. jg Values for (DFAt )a were obtained from Tables E-7 through E-10'of Regulatory Guide 1.109 and are presented in Tables 3.5-1 through 3.5-4 of this Manual.
! 3.5.2.1.2 Calculation of the Ground Plane Pathway Factor, RO -. -
R C = K'K" (SF) (DFG g ) (1-e - t)/(,(8) m -mrem / year per pCi/see where 0 K' = A units conversion constant, 10 pCi/pCi K" = A units conversion constant, 8760 , hour / year { SF = The shielding factor, dimensionless -
- 0.7 as suggested in Table E-15 of I.) Regulatory Guide 1.109 , CLINTON-I 3-18 Rev.1-11/85 i- - - - - - - -----------__-_-a---._m _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ ,
CPS-0DCM DFG The ground plane dose conversion f= factor for radionuclides i, mrem / hour per pCi/m2 . Values for 9 DFG, were obtained from Table E-6 of Regulatory Guide 1.109 and are ! presented in Table 3.5-5 of this l Manual. I The decay constant for x1 - radionuclides 1, sec -1 t= The exposure time, sec
= 6.31E+08 see (20 years) 3.5.2.1.3 Calculation of The Grass-Cow / Goat-Milk Pathway Factor, RC aij C
R aij = K' 9 (Uap) F F ,(r) (DFLf ), (9)
~
Af+A y 4 t -A t fp f, + (1-f pgf )e ih e i f,
. P s ,
m2-mrem /yr per pC1/sec 9 where K' = A units conversion constant, 10 6 pCi/pCi Qp = The cow / goat feed consumption rate, kg(wet)/ day U ap
= The receptor's milk consumption rate for age group (a),'
liters / year Y = The agricultural productivity by P unit area of pasture feed grass, kg/m 2 Y = The agricultural productivity by s unit area of stored feed, kg/m2 The stable element transfer F" = coefficients, days / liter r= Fraction of deposited activity retained on feed grass, dimensionless O CLINTON-I 3-19 Rev.5-2/89
s : CPS-ODCM b (DFLg )a = The organ ingestion dose' factor cX for' radionuclides i and.the ()- , receptor in age group (a), mrem /pCi. Values.for..(DFLf ), I were obtained from Tables E-ll through E-14 of' Regulatory Guide 1.109 and are. presented in Table 3.5-6 through 3.5-9 of this Manual.. xi = The decay constant for' radionuclides i,.sec~ x* = The decay constant for removal of 1 activity on leaf and plant _1 , surfaces by weathering, sec !
= 5.73 x 10~7 sec ~1 (corresponding to a 14-day half-life) ..
t f = The transport time from pasture , to animal, to milk, to receptor, l sec l l t h = The transport time from pasture i to harvest, to animal, to receptor, sec f = Fraction of the year that the P cow / goat is on pasture, dimensionless-
. f = Fraction of the cow / goat feed 8 ',
that is pasture grass while the cow / goat is on pasture, dimensionless , The in ut pa gmeters for calcul ting are listed in Table 3.5-10.aij Tritiums The concentration of tritium in milk is based on its airborne concentration rather than the deposition. j RC , g,gny 9 Um F ap(DFL t ), [0.75(0.5/H)], mrem /yr per pCi/m3 (10) ! CLINTON-I 3-20 Rev.5-2/89
CPS-0DCM i
'w,/ ) l where ;
K" = A units conversion constant, 10 3
!- gm/kg .
H = The absolute atmospheric humidity
= 8 gm/m3 (NUREG-0133, p. 34) 0.75 = The fraction of total feed that is water., dimensionless 0.5 - The ratio of the specific activity of the feed grass water t to the atmospheric water, dimensionless The other parameters are as defined in the calculationofR[f) i Carbon - 14 ,
Following the development of equation C-8 on page Cs
) _.s 1.109-26 of Regulatory Guide 1.109, carbon-14 is t )
assumed to be released as an oxide, either C140 or
\ ;'
C140 2. The concentration of carbon-14 in milk is therefore based upon its airborne concentration 14 j assuming that the vegetation C /C ratio is the same
' 14 i
as the local atmospheric C /C rn.tio. 1 3 Rf4=K'K"F9U,p(DFL),p(0.11/0.16), mf t mrem /yr per pCi/m (11) where j p = Fractional equilibrium ratio, dimensionless
= Ratio of the total annual C-14 atmospheric release time to the total annual photosynthesis time (4400 hours) not to exceed unity = 1.0 .
l l 0.11 - Natural carbon fraction of total plant mass, . dimensionless
\ 3 0.16 = Atmospheric natural carbon concentration, gm/m C The other parameters are as defined in the calculation of RT .
CLINTON-I 3-21 Rev.1-11/85
CPS-0DCM
-. , i 3.5.2.1.4 Calculation of The Grass-Cow-Meat Pathway Factor, R ps+(
I K 1) = K'9F(U,p) p f) s e U ih [e i t s], Ff (r)(DFL1)a Y
^i M w ,
Y p s , m -mrem /yr per p Ci/sec 2 (12) where K' r-A gnits conversion constant, 10 pCi/ECi U = tion ap The ratereceptor's meat consump/ for age group (a), kg year Ff= The stable element transfer coefficient, days /kg I t = The transport time from slaughter 8 of meat animal to receptor, seconds The transport time from crop l th= field to receptor, seconds (DFL 1 ),= The organ ingestion dose factor for radionuclides i and the receptor in age group (a), mrem per pC1. Values are tabulated in Table 3.5-6 through 3.5-9 of r,his l Manual. i The input parameters necessary for calculating R 1) are listed in Table 3.5-11. All other terms are c.s defined for equations (9) and (10).
' Tritium:
The concentration of tritium in meat is based on its airborne concentration rather than the deposition. [0.75(0.5/H)] , mrem /yr per R = K'K"FfQpU ap(DFLy ), i p Ci/m3 (13) 1
- The terms in equation (13) are as defined in equations (10) and (12).
( CLINTON-I 3-22 Rev.1-11/85
,.1.
t p CPS-ODCM: 3- Carbon - 14 I I Following the development of equation C-8 on'page 1.109-26 of Regulatory Guide 1.10h carbop 14 is-assumed to be released as an oxide, either C 0 or C 0. 2 The concentration of carbon-14 in meat is therefore based up'on its airborne 10 concentration assuming that the vegetation C /C' ratio is the 10 ' same as the local atmospheric C /C ratio. l-RM4 = pCi/m 3 (14).
- f. K'K"Fff Q U,p(DFLg ), p(0.11/0,16) . mrem /yr per 3
The terms in equation (14) are as defined in equations (11) and (13). ,
'l' 3.5.2.1.5 Calculation of the Vegetation Pathway Factor, R g) .
U 6 ih R gj = C Y(Ag+A)p (E g), Uhfe~iL+Ufe-At g g y d m2 -mrem /yr per UCi/sec (15) ]
.f 3 . where .
K' = A units conversion constant, 10 pCi/pci E = The consumption rate of fresh U 8 leafy vegetation by the receptor in age group (a), kg/yr ~ U S = The consumption rate of stored a the receptor in age r vegetation group (a), kg by/yr f L
= The fraction of the annual intake i of fresh leafy vegetation grown locally, dimensionless '! f = The fraction of the annual intake 8 of stored vegetation grown i
locally, dimensionless
- tg = The average time between harvest
}
of leafy vegetation and its , consumption, seconds 1 i
- The average time between harvest p t h of stored vegetation and its g~ .
consumption, seconds Rev.1-11/85 CLINTON-I 3-23
l l l' CPS-0DCM
]
[ Yy = The vegetation areal density, kg/m2 l (DFL t )"= The organ ingestion dose factor i for radionuclides i and the I receptor in age group (a), mrem per pCi. Values are tabulated in i Tabic 3.5-6 through 3.5-9 of this Manual. - The input parameters necessary for l V calculating Raij are listed in Table 3.5-12. All other terms are as defined for equations (9) through (14). Tritium: The concentration of tritium in vegetation is based on i its airborne concentration rather than the deposition. 8 k=K'K"(Ufft+Uf) ag (DFL 1 ), [0.75(0.5/H)] , mrem /yr per pC1/m3 (16) ; The terms in equation (16) are as defined in equations (10) and (15). Carbon-14 Following the development of equation C-8 on page 1.109-26 of Regulatory Guide 1.109, carbon-1 4s 1 i assumed to be released as an oxide, either C 0 or ~ 14 C 0. The concentrr. tion of carbon-14 in vegetation 2 is therefore based upon its airborne concentration assuming that the vegetation C 14 /C ratio is the same 14 as the local atmospheric C /C ratio. 8 (DFL f ),p(0.11/0.16), (17) Rf4=K'K"(Uft+Uf) g I mrem /yr per p Ci/m' The terms in equation (17) are as defined in equations (11) and (15). l The pathway dose rate factors (Rfg3,Rff),R 13, R f) , ~
/*~ Rf), by age group, are listed in Table 3.5-13 Y through 3.5-31.
CLINTON-I 3-24 Rev.1-11/85 l l _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - - - - - - _ _ ]
.y f ' CPS-0DCM .g (m. ? \) .
Compliance With CPS-RETS 3.11.2.4/3.11.2.5
) '3.6 i
CPS RETS 3.11.2.4' requires that the Offgas Treatment l [ . System shall not be used in the charcoal bypass mode unless the. Post-Treatment Air Ejector Offgas radiation l {. monitor is operable per CPS RETS 3.3.7.12. Prior to i ( L placing the Offgas. Treatment System in the charcoal I bypass mode, the alarm setpoints for the Station HVAC Exhaust and the Post-Treatment Offgas radiation monitors shall be calculated to account for the. increased fractions of short-lived noble gases. The noble gas release fractions shall.be based either on actual measured values or on design basis noble gas concentration fractions (30 i minute decay) in the primary coolant offgas. CPS RETS 3.11.2.5 requires that the Ventilation Exhaust Treatment System (VETS) shall be used when the projected doses due to VETS releases to' areas at and beyond the Site Boundary would exceed 0.3 mrem to any organ in a 31 day period. The projected' doses
}
resulting from such releases will be calculated using ODCM section 3.5.2 methodology. If the dose impact resulting from the projected 31 day release exceeds 0.3 mrem and the VETS is capable of reducing the E~ projected impact to less than 0.3 mrem, the VETS shall
'} ,
be used. j.f 3.7 Effluent Monitor Setpoint Calculations Gaseous effluent Process Radiation Monitor (PRM) alarm setpoints shall be calculated to' ensure that'the dose rate in unrestricted areas due to noble gases released i do not exceed 500 mrem / year to the total body and 3000 l- nrem/ year to the skin. The initial setpoints will he calculated using the BWR-GALE code radionuclides mix obtained for CPS: once CPS becomes operational, the actual radionuclides mix will be used. The PRM setpoints are based on the instantaneous noble gas dose rates and are applied at the point of which the effluent enters an unrestricted area. Further, the bases for each setpoint consider the type of release at the PRM location (long or short term using the appropriate atmospheric dispersion conditions). Due to PRM limitations, non-noble gas setpoints will not be implemented to demonstrate compliance with CPS RETS 3.11.2.1(b). Compliance with the organ dose rate limitation is demonstrated during performance of sampling and analysis activities required by CPS RETS Table 4.11.2-1. - i I .
"LINTON-I 3-25 Rev.2-10/86
_ _ _ _ _ _ _ _ _ ____-_____________1--- - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
CPS-0DCM _ 1 l Both total body and skin dose setpoints will be calculated and the more restrictive limit applied to j the respective PRM. The actual setpoint used may be
- lower than the restrictive limit since the two release .
points will be partitioned such that their sum does I not exceed 100 percent of the restrictive limit. The k percentages used to partition the release points could vary at plant discretion to accommodate plant operational conditions. In no case will the combined releases due to variations in the PRM setpoints result
; in RETS limits being exceeded.
I
! 3.7.1 Total Body Dose Rate Setpoint l The fraction of the total gaseous radioactivity in each gaseous effluent release path j for each noble gas radionuclides i shall be determined using j the following relationship:
C , dimensioniess ij (18) f)= f ij l
, i where C
ij
= The measured concentration of identified noble gau radionuclides i in gaseous effluent release path j , p Ci/cc The maximum acceptable release rate of all noble gases in release path j to comply with CPS RETS 3.11.2.1 is calculated by i using the equation:
500 #j , pCi/sec (19) Q)= 7 (X/Q)3 (Kift )) where Q = The maximum acceptable release T3 rate of all noble gases in release path j , pCi/sec F = Total dose rate allocation factor 3 assigned to release path j (varying between 0.0 and 1.0), dimensionless
'N /'-
CLINTON-I 3-26 Rev.1-ll/85 L------ _ _
CPS-0DCM
.f~)
500 - Total body dose rate limit specified in CPS RETS 3.11.2.la, mrem / year
= The highest relative (X/Q)3 concentration of release path j at.the site boundary =
(XTQ) or (x/q) de duratTon of relEa,se,pending sec/m* on (reference section 3.5.1) K = The total body dose factor due to f gamma emissions of noble gas radionuclides i as listed in Table B-1 of Regulatory Guide.l.109 and Table 3.4-1 of this Manual, mrem /yr per p C1/m3 f)= f The fraction as defined by equation (18), dimensionless The total maximum acceptable concentration setpoint of noble gas radionuclides in l :T.76 release path j is calculated using the following equation:
.CTj." ' pCi/cc (20)
J where
! C Tj = The total maximum acceptable ~
concentration setpoint of all 'l noble gases in release path j, UCi/cc Q = The maximum acceptable release
~
Td rate of all noble gases in
. release path j determined from equation (19), pCi/see R = The effluent release rate of J release point j, cc/sec i CLINTON-I 3-27 Rev.2-10/86 !
L LCPS-0DCM 3.7.2 Skin Dose Rate Setpoint )
, x l /)
q To ensure compliance with the CPS RETS { 3.ll.2.la skin dose rate limit, PRM { l setaoints shall be calculated using the j methodology presented in section 3.7.l'and by substituting the following equation for equation (19): 3000 F j Ci/sec (21) Q)= 3 a t+1.lM t)t ij (X/Q)3rt where The maximum acceptable release Q33 = rate of all noble gases in release path j , pCi/sec F Total dose rate allocation factor 3= assigned to release path j (varying between 0.0 and 1.0), dimensionless 3000= Skin dose rate limit specified in CPS RETS 3.ll.2.la, mrem / year (X/Q)) = concentration TM highest relative of release path j at the site boundary
=
(X7Q) ,or (x/q), depending on duration of release, sec/m3 (reference section 3.5.1) Li= The skin dose factor due to gamma emissions for each identified noble gas radionuclides i, mrem /yr per p Ci/m3, as listed in Table 3.4-1 of this Manual. 1.1 - An air dose to skin dose equivalent ; conversion factor, mrem / mrad M t= The air dose factor due to gamma emissions for each identified noble gas radionuclides i, mrad /yr j per pCi/m3, as listed in Table 1 3.4-1 of this Manual f The fraction defined by equation t3 = (18) O CLINTON-I 3-28 Rev.5-2/89 <
CPS-0DCM
'-) The calculated total body and skin maximum acceptable concentration setpoints are l compared and the more restrictive setpoint used. A safety factor may also be applied to the concentration setpoint calculated , by equation (20) to compensate for l statistical fluctuations and measurement errors.
1 "Tt
\~' 3-29 Rev.2-10/86 CLINTON-I t
L_..__._.
!11 l I
1i!lI1 Qen oc. e nu S R, R - .f E E t. E T F 0 S N Y E WWW 3 BIO
.O 6 O
T O P .P ON P Y U$LI O L DlLD 3 SI S E D YIN ITI E D E
,ERWH O t
O.OAO T A A T N TAD TC N INTN I SI L MI E R t) C . W NNUT L L L LOIL X r1 EO EU BN i I O Y A T R D Se ITS O T _EO .E Y IYtN Y R A E Eo R t WDEU T M F L B OPD P P M D N C N Ne HY NN EAI F *ED OUE D T I A DET E N EN P N S D U RS I R U. e TR 'E AtT I N O B TS A( tS IAD W WSWEW E N E I E CA AN S E K HN .OCOI ANTAE L T O .EE NN G E R C c EU LOIT L EIIL E T I t? PR RO T ESA R T N T E SL P. UOEOPO O HU D L S j l SA AD N TLOIO FSN IN P t M. URN L E A ]d LS LY LAOO
- CEDL EE E ERHIT / 7 NIETEC SCL CRCNACUSA - / / $
f[ $Q A ILTRSR EERONAEA RHT ATSRAPDP M P RTEV U O CL E ALKE PUAL E TRD LDCDI S EDRNRN NREL T ) HNNOAACN N At L t AOHS N P Y T. AUCW L. 3I'.OL A- ST. W 4. E T 3 2 U , ( E L C~ F N F E D E I S Y E R S R A U 8 D)5 N O 4 UE OT E Y nO 1 S , W ' i Et l
- A H K <
1 G A L O3 e F r R O fo gS T TN NI EO ' 4 3 u g R Y /
/ UP M 1
E T FE U L Y L O i A FG ER F WtI N F D 0tH A E Q' N uC R G / U OS A / O
- tILDCS f jj B [/
T ID j / E N A jr [ ' o T L t I W P,d Jy(F ' Y S I W H
/ ,
S O / P F F M C ;; J [- 1 // E - T O N
/ " v 2 -N 4 _
_ E . _ T E O T _ N O N O-
@mZeO H gfuO U*4* .NNCD J _
Il 1(:l l1l il '
CPS-0DCM a FIGURE 3.3-1 MAIN CONDENSER OFF-GAS TREATMENT SYSTEM f f.PR555 ye,ppo,$
- ~
IN66Z003A _ _ T 1PRMS
! b SW m.a _ 'loamo a g y gy,c / <
i # pgj3 i 2 STAcx
/muo]i., __ _
g ' g I I l was oors p I X lswuoco34 ' g d' a6 ~
/******* ; y ,h g a m oooss 1
- 30056 scAotAA sc,,Aot A 6 ggg 2
m r, r, y A A spa otAotT6 ,,,,,,
-+- SGTS Exha us t
( 9 ) .. 1CDOl A
****8'8 Stack
( ) pg i' Primary / Seconuary Contairroent Exhaust
- Monitors required by CPS TECHNICAL SPECIFICATIONS 1CD01A Main OCA01TA CV IN66B010B Cooler 1N66D013 IFR35S Off-Gas Condenser Separator Tank A Condenser B Charcoal Adsorber Post Treatment PRM 1CA01AA Steam Jet OCA01TB CV 1N66Z003A IN66D016 HEPA 1PR41S Off-Gas Air Ejector A Separator Tank B Dessicant Dryer A Filter Post Treatment PRM 1CA01AB Steam Jet IN66D005A IN662003B OPR01S HVAC 1PR003 Standby Gas Air Ejector B Recombiner A Dessicant Dryer B Stack PRM #1 Treatment PRM OCA01PA Condenser IN66D005B IN66B011 Cas OPR02S HVAC 1PR004 Standby Gas Vacuum (CV) Pump A Recombiner B Cooler Stack PRM #2 Treatment PRM OCA01PB CV Pump B IN66B010A Cooler 1N66D012 1PR34S Off-cas Condenser A Charcoal Adsorber Retreatment PRM -
CLINTON-I 3-31 Rev.2-10/86
CPS-ODCM Table 3.5-1 O ""At^r1o" nosz r^croas roa "r^"r - cor^1)e (mrem per pCi inhaled) NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI H-3 NO DATA 4.62E-07 4.62E-07 4.62E-07 4.62E-07 4.62E-07 4.62E-07 C-14 1.89E-05* 3.79E-06 3.79E-06 3.79E-06 3.79E-06 3.79E-06 3.79E-06 NA-24 7.54E-06 7.54E-06 7.54E-06 7.54E-06 7.54E-06 7.54E-06 7.54E-06 P- 32 1.45E-03 8.03E-05 5.53E-05 NO DATA NO DATA NO DATA 1.15E-05 CR-51 NO DATA NO DATA 6.39E-08 4.11E-08 9.45E-09 9.17E-06 2.55E-07 . MN-54 NO DATA 1.81E-05 3.56E-06 NO DATA 3.56E-06 7.14E-04 5.04E-06 . MN-56 NO DATA 1.10E-09 1.58E-10 NO DATA 7.8bE-10 8.95E-06 5.12E-05 FE-55 1.41E-05 8.39E-06 2.38E-06 NO DATA NO DATA 6.21E-05 7.82E-07 ' FE-59 9.69E-06 1.68E-05 6.77E-06 NO DATA NO DATA 7.25E-04 1.77E-05 CO-58 NO DATA 8.71E-07 1.30E-06 NO DATA NO DATA 5.55E-04 7.95E-06 00-60 NO DATA 5.73E-06 8.41E-06 NO DATA NO DATA 3.22E-03 2.28E-05 NI-63 2.42E-04 1.46E-05 8.29E-06 NO DATA NO DATA 1.49E-04 1.73E-06 O NI-65 1.71E-09 2.03E-10 8.79E-11 NO DATA NO DATA 5.80E-06 3.58E-05 CU-64 NO DATA 1.34E-09 5.53E-10 NO DATA 2.84E-09 6.64E-06 1.07E-05 ZN-65 1.38E-05 4.47E-05 2.22E-05 NO DATA 2.32E-05 4.62E-04 3.67E-05 I ZN-69 3.85E-11 6.91E-11 5.13E-12 NO DATA 2.87E-11 1.05E-06 9.44E-06 BR-83 NO DATA NO DATA 2.72E-07 NO DATA NO DATA NO DATA LT E-24** BR-84 NO DATA NO DATA 2.86E-07 NO DATA NO DATA NO DATA , LT E-24 BR-85 NO DATA NO DATA 1.46E-08 NO DATA NO DATA NO DATA LT E-24 ' RB-86 NO DATA 1.36E-04 6.30E-05 NO DATA NO DATA NO DATA 2.17E-06 RB-88 NO DATA 3.98E-07 2.05E-07 NO DATA NO DATA NO DATA 2.42E-07 1 RB-89 NO DATA 2.29E-07 1.47E-07 NO DATA JJ DATA NO DATA 4.87E-08 SR-89 2.84E-04 NO DATA 8.15E-06 NO DATA NO DATA 1.45E-03 4.57E-05 SR-90 2.92E-02 NO DATA 1.85E-03 NO DATA NO DATA 8.03E-03 9.36E-05 SR-91 6.83E-08 NO DATA 2.47E-09 NO DATA NO DATA 3.76E-05 5.24E-05 SR-92 7.50E-09 NO DATA 2.79E-10 NO DATA NO DATA 1.'/0E-05 1.00E-04 Y-90 2.35E-06 NO DATA 6.30E-08 NO DATA NO DATA 1.92E-04 7.43E-05 O . CLINTON-I 3-32 Rev.5-2/89
l l 1 Table 3.5-1 (continued) ( ) INHALATION DOSE FACTORS FOR INFANT - (DFA f ), (mrem per pCi inhaled) NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI Y-91m 2.91E-10 NO DATA 9.90E-12 NO DATA NO DATA 1.99E-06 1.68E-06 Y-91 4.20E-04 NO DATA 1.12E-05 NO DATA NO DATA 1.75E-03 5.02E-05 Y-92 1.17E-08 NO DATA 3.29E-10 NO DATA NO DATA 1.75E-05 9.04E-05 Y-93 1.07E-07 NO DATA 2.91E-09 NO DATA NO DATA 5.46E-05 1.19E-04 ZR-95 8.24E-05 1.99E-05 1.45E-05 NO DATA 2.22E-05 1.25E-03 1.55E-05 ZR-97 1.07E-07 1.83E-08 8.36E-09 NO DATA 1.85E-08 7.88E-05 1.00E-04 NB-95 1.12E-05 4.59E-06 2.70E-06 NO DATA 3.37E-06 3.42E-04 9.05E-06 M0-99 NO DATA 1.18E-07 2.31E-08 NO DATA 1.89E-07 9.63E-05 3.48E-05 TC-99m 9.98E-13 2.06E-12 2.66E-11 NO DATA 2.22E-11 5.79E-07 1.45E-06 TC-101 4.65E-14 5.88E-14 5.80E-13 NO DATA 6.99E-13 4.17E-07 6.03E-07 RU-103 1.44E-06 NO DATA 4'.85E-07 NO DATA 3.03E-06 3.94E-04 1.15E-05 RU-105 8.74E-10 NO DATA 2.93E-10 NO DATA 6.42E-10 1.12E-05 3.46E-05
,s RU-106 6.20E-05 NO DATA 7.77E-06 NO DATA 7.61E-05 8.26E-03 1.17E-04 AG-110m 7.13E-06 5.16E-06 3.57E-06 NO DATA 7.80E-06 2.62E-03 2.36E-05 TE-125m 3.40E-06 1.42E-06 4.70E-07 1.16E-06 NO DA*1A 3.19E-04 9.22E-06 i
TE-127m 1.19E-05 4.93E-06 1.48E-06 3.48E-06 2.68E-05 9.37E-04 1.95E-05 TE-127 1.59E-09 6.81E-10 3.49E-10 1.32E-09 3.47E-09 7.39E-06 1.74E-05 TE-129m 1.01E-05 4.35E-06 1.59E-06 3.91E-06 2.27E-05 1.20E-03 , 4.93E-05 TE-129 5.63E-11 2.48E-11 1.34E-11 4.82E-11 1.25E-10 2.14E-06 1.88E-05 TE-131m 7.62E-08 3.93E-08 2.59E-08 6.38E-08 1.89E-07 1.42E-04 8.51E-05 TE-131 1.24E-11 5.87E-12 3.57E-12 1.13E-11 2.85E-11 1.47E-06 5.87E-06 TE-132 2.66E-07 1.69E-07 1.26E-07 1.99E-07 7.39E-07 2.43E-04 3.15E-05 I-130 4.54E-06 9.91E-06 3.98E-06 1.14E-03 1.09E-05 NO DATA 1.42E-06 I-131 2.71E-05 3.17E-05 1.40E-05 1.06E-02 3.70E-05 NO DATA 7.56E-07 I-132 1.21E-06 2.53E-06 8.99E-07 1.21E-04 2.82E-06 NO DATA 1.36E-06 I-133 9.46E-06 1.37E-05 4.00E-06 2.54E-03 1.60E-05 NO DATA 1.54E-06 I-134 6.58E-07 1.34E-06 4.75E-07 3.18E-05 1.49E-06 NO DATA 9.21E-07 0J CLINTON-I 3-33 Rev.5-2/89
CPS-0DCM Table 3.5-1 (continued) (,,) INHALATION DOSE FACTORS FOR INFANT - (DFA 1 ), I (mrem per pCi inhaled) NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI I-135 2.76E-06 5.43E-06 1.98E-06 4.97E-04 6.05E-06 NO DATA 1.31E-06 ; CS-134 2.83E-04 5.02E-04 5.32E-05 NO DATA 1.36E-04 5.69E-05 9.53E-07 CS-136 3.45E-05 9.61E-05 3.78E-05 No DATA 4.03E-05 8.40E-06 1.02E-06 CS-137 3.92E-04 4.37E-04 3.2SE-05 NO DATA 1.23E-04 5.09E-05 9.53E-07 CS-138 3.61E-07 5.58E-07 2.84E-07 NO DATA 2.93E-07 4.67E-08 6.26F-07 BA-139 1.06E-09 7.03E-13 3.07E-11 NO DATA 4.23E-13 4.25E-06 3.64E-05 BA-140 4.00E-05 4.00E-08 2.07E-06 NO DATA 9.59E-09 1.14E-03 2.74E-05 BA-141 1.12E-10 7.70E-14 3.55E-12 NO DATA 4.64E-14 2.12E-06 3.39E-06 BA-142 2.84E-11 2.36E-14 1.40E-12 NO DATA 1.36E-14 1.11E-06 4.95E-07 LA-140 3.61E-07 1.43E-07 3.68E-08 NO DATA NO DATA 1.20E-04 6.06E-05 LA-142 7.36E-10 2.69E-10 6.46E-11 NO DATA NO DATA 5.87E-06 4.25E-05 CE-141 1.98E-05 1.19E-05 1.42E-06 NO DATA 3.75E-06 3.69E-04 1.54E-05
/N V
CE-143 2.09E-07 1.38E-07 1.58E-08 NO DATA 4.03E-08 8.30E-05 3.55E-05 CE-144 2.28E-03 8.65E-04 1.26E-04 NO DATA 3.84E-04 7.03E-03 1.06E-04 PR-143 1.00E-05 3.74E-06 4.99E-07 NO DATA 1.41E-06 3.09E-04 2.66E-05 PR-144 3.42E-11 1.32E-11 1.72E-12 NO DATA 4.80E-12 1.15E-06 3.06E-06 ND-147 ' 5.67E-06 5.81E-06 3.57E-07 NO DATA 2.25E-06 2.30E-04 2.23E-05 W-187 9.26E-09 6.44E-09 2.23E-09 NO DATA NO DATA 2.83E-05 2.54E-05 NP-239 2.65E-07 2.37E-08 1.34E-08 NO DATA 4.73E-08 4.25E-05 1.78E-05 l
- 1.89 X 10-05
** Less than 10-24 l
l l i l l l CLINTON-I 3-34 Rev.5-2/89 l l
l CPS-0DCM Table 3.5-2 () INHALATION DOSE FACTORS FOR CHILD - (DFAt )a I (mrem per pCi inhaled) NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI H-3 NO DATA 3.04E-07 3.04E-07 3.04E-07 3.04E-07 3.04E-07 3.04E-07 C-14 9.70E-06* 1.82E-06 1.82E-06 1.82E-06 1.82E-06 1.82E-06 1.82E-06 NA-24 4.35E-06 4.35E-06 4.35E-06 4.35E-06 4.35E-06 4.35E-06 4.35E-06 P-32 7.04E-04 3.09E-05 2.67E-05 NO DATA NO DATA NO DATA 1.14E-05 CR-51 NO DATA NO DATA 4.17E-08 2.31E-08 6.57E-09 4.59E-06 2.93E-07 MN-54 NO DATA 1.16E-05 2.57E-06 NO DATA 2.71E-06 4.26E-04 6.19E-06 MN-56 NO DATA 4.48E-10 8.43E-11 NO DATA 4.52E-10 3.55E-06 3.33E-05 FE-55 1.28E-05 6.80E-06 2.10E-06 NO DATA NO DATA 3.00E-05 7.75E-07 FE-59 5.59E-06 9.04E-06 4.51E-06 NO DATA NO DATA 3.43E-04 1.91E-05 C0-58 NO DATA 4.79E-07 8.55E-07 NO DATA NO DATA 2.99E-04 9.29E-06 CO-60 NO DATA 3.55E-06 6.12E-06 NO DATA NO DATA 1.91E-03 2.60E-05 NI-63 2.22E-04 1.25E-05 7.56E-06 NO DATA NO DATA 7.43E-05 1.71E-06 /} J NI-65 8.08E-10 7.99E-11 4.44E-11 NO DATA NO DATA 2.21E-06 2.27E-05 CU-64 NO DATA 5.39E-10 2.90E-10 NO DATA 1.63E-09 2.59E-06 9.92E-06 ZN-65 1.15E-05 3.06E-05 1.90E-05 NO DATA 1.93E-05 2.69E-04 4.41E-06 ZN-69 k.81E-11 2 61E-11 2.41E-12 NO DATA 1.58E-11 3.84E-07 2.75E-06 l BR-83 NO DATA NO DATA 1.28E-07 NO DATA NO DATA NO DATA LT E-24** BR-84 NO DATA NO DATA 1.48E-07 NO DATA NO DATA NO DATA , LT E-24 BR-85 NO DATA NO DATA 6.84E-09 NO DATA NO DATA NO DATA LT E-24 RB-86 NO DATA 5.36E-05 3.09E-05 NO DATA NO DATA NO DATA 2.16E-06 RB-88 NO DATA 1.52E-07 9.90E-08 NO DATA NO DATA NO DATA 4.66E-09 RB-89 NO DATA 9.33E-08 7.83E-08 NO DATA NO DATA NO DATA 5.11E-10 SR-89 1.62E-04 NO DATA 4.66E-06 NO DATA NO DATA 5.83E-04 4.52E-05 SR-90 2.73E-02 NO DATA 1.74E-03 NO DATA NO DATA 3.99E-03 9.28E-05 CLINTON-I 3-35 Rev.5-2/89
CPS-ODCM Table 3.5-2 (continued) INHALATION DOSE FACTORS FOR CHILD - (DFAf ) (mrem per pCi inhaled) i 1 NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI l l SR-91 3.28E-08 NO DATA 1.24E-09 NO DATA NO DATA '1.44E-05 4.70E-05 i 'SR-92 3.54E-09 NO DATA 1.42E-10 NO DATA NO DATA 6.49E-06 6. 55E- 05
! Y-90 1.11E-06 NO DATA 2.99E-08 NO DATA NO DATA 7.07E-05 7.24E-05 I Y-91m 1.37E-10 NO DATA 4.98E-12 NO DATA NO DATA 7.60E-07 4.64E-07 I Y-91 2.47E-04 NO DATA 6.59E-06 NO DATA NO DATA 7.10E-04 4.97E-05 l Y-92 5.50E-09 NO DATA 1.57E-10 NO DATA NO DATA 6.46E-06 6.46E-05 l
Y-93 5.04E-08 NO DATA 1.38E-09 NO DATA NO DATA 2.01E-05 1.05E-04
, ZR-95 5.13E-05 1.13E-05 1.00E-05 NO DATA 1.61E-05 6.03E-04 1.65E-05 ZR-97 5.07E-08 7.34E-09 4.32E-09 NO DATA 1.05E-08 3.06E-05 9.49E-05 l
NB-95 6.35E-06 2.48E-06 1.77E-06 NO DATA 2.33E-06 1.66E-04 1.00E-05 , MO-99 NO DATA 4.66E-08 1.15E-08 NO DATA 1.06E-07 3.66E-05 3.42E-05 TC-99m 4.81E-13 9.41E-13 1.56E-11 NO DATA 1.37E-11 2.57E-07 1.30E-06 TC-101 2.19E-14 2.30E-14 2.91E-13 NO DATA 3.92E-13 1.58E-07 4.41E-09 RU-103 7.55E-07 NO DATA 2.90E-07 NO DATA 1.90E-06 1.79E-04 1.21E-05 RU-105 4.13E-10 NO DATA 1.50E-10 NO DATA 3.63E-10 4.30E-06 2.69E-05 4.57E-06 NO DATA 4.97E-05 3.87E-03 1.16E;04 RU-106 3.68E-05 NO DATA AC-110m 4.56E-06 3.08E-06 2.47E-06 NO DATA 5.74E-06 1.48E-03 2.71E-05
! TE-125m 1.82E-06 6.29E-07 2.47E-07 5.20E-07 NO DATA 1.20E-04 9.13E-06 TE-127m 6.72E-06 2.31E-06 8.18E-07 1.64E-06 1.72E-05 4.00E-04 1.93E-05 TE-127 7.49E-10 2.57E-10 1.65E-10 5.30E-10 1.91E-09 2.71E-06 1.52E-05 TE-129m 5.19E-06 1.85E-06 8.22E-07 1.71E-06 1.36E-05 4.76E-04 4.91E-05 TE-129 2.64E-11 9.45E-12 6.44E-12 1.93E-11 6.94E-11 7.93E-07 6.89E-06 TE-131m 3.63E-08 1.60E-08 1.37E-08 2.64E-08 1.0SE-07 5.56E-05 8.32E-05 TE-131 5.87E-12 2.28E-12 1.78E-12 4.59E-12 1.59E-11 5.55E-07 3.60E-07 i
TE-132 1.30E-07 7.36E-08 7.12E-08 8.58E-08 4.79E-07 1.02E-04 3.72E-05 I-130 2.21E-06 4.43E-06 2.28E-06 4.99E-04 6.61E-06 NO DATA 1.38E-06 I 131 1.30E-05 1.30E-05 7.37E-06 4.39E-03 2.13E-05 NO DATA 7.68E-07 J-
' /
CLINTON-I 3-36 Rev.1-11/85 !
CPS-0DCM O Table 3.5-2 (continued) INHALATION DOSE FACTORS FOR CHILD - (DFA1 ) i (mrem per pCi inhaled) EONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI NUCLIDE l I-132 5.72E-07 1.10E-06 5.07E-07 5.23E-05 1.69E-06 'NO DATA 8.65E-07 I-133 4.48E-06 5.49E-06 2.08E-06 1.04E-03 9.13E-06 NO DAT A 1.48E-06 I-134 3.17E-07 5.84E-07 2.69E-07 1.37E-05 8.92E-07 N0 DATA 2.58E-07 1.33E-06 2.36E-06 1.12E-06 2.14E-04 3.62E-06 NO DATA 1.20E-06 I-135 CS-134 1.76E-04 2.74E-04 6.07E-05 NO DATA 8.93E-05 3.27E-05 1.04E-06 CS-136 1.76E-05 4.62E-05 3.14E-05 NO DATA 2.58E-05 3.93E-06 1.13E-06 CS-137 2.45E-04 2.23E-04 3.47E-05 NO DATA 7.63E-05 2.81E-05 9.78E-07
. CS-138 1.71E-07 2.27E-07 1.50E-07 NO DATA 1.68E-07 1.84E-08 7.29E-08 BA-139 4.98E-10 2.66E-13 1.45E-11 NO DATA 2.33E-13 1.56E-06 1.56E-05 l
BA-140 2.00E-05 1.75E-08 1.17E-06 NO DATA 5.71E-09 4.71E-04 2.75E-03 ;,;;;, BA-141 5.29E-11 2.95E-14 1.72E-12 NO DATA 2.56E-14 7.89E-07 7.44E-03 BA-142 1.35E-11 9.73E-15 7.54E-13 NO DATA 7.87E-15 4.44E-07 7.41E-10 LA-140 1.74E-07 6.08E-08 2.04E-08 NO DATA NO DATA 4.94E-05 6.10E-05 LA-142 3.50E-10 1.11E-10 3.49E-11 NO DATA NO DATA 2.35E-06 2.05E-05 CE-141 1.06E-05 5.28E-06 7.83E-07 NO DATA 2.31E-06 1.47E-04 1.53E-35 CE-143 9.89E-08 5.37E-08 7.77E-09 NO DATA 2.26E-08 3.12E-05 3.44605 CE-144 1.83E-03 5.72E-04 9.77E-05 NO DATA 3.17E-04 3.23E-03 1.05E-04 4.99E-06 1.50E-06 2.47E-07 NO DATA 8.11E-07 1.17E-04 2. 63E -05
' PR-143 PR-144 1.61E-11 4.99E-12 8.10E-13 NO DATA 2.64E-12 4.23E-07 5.32E-08 ND-147 2.92E-06 2.36E-06 1.84E-07 NO DATA 1.30E-06 8.87E-05 2.22f-05 W-187 4.41E-09 2.61E-09 1.17E-09 NO DATA NO DATA 1.11E-05 2.46E-05 NP-239 1.26E-07 9.04E-09 6.35E-09 NO DATA 2.63E-08 1.57E-05 1.73E-05 i
i
- 9.70 X 10 24
** Less than 10 O/
CLINTON-I 3-37 Rev.1-11/85
i l CPS-0DCM
'Ie Table 3.5-3 INHitLAT' ION DOSE FACTORS FOR TEEN - (DFA 1 ),
(mrem per pCi inhaled)
! NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG CI-LLI l H-3 NO DATA 1.59E-07 1.59E-07 1.59E-07 1.59E-07 '1.59E-07 1.59E-07 l C-14 3.25E-06* 6.09E-07 6.09E-07 6.09E-07 6.09E-07 6.09E-07 6.09E-07 NA-24 1.72E-06 1.72E-06 1.72E-06 1.72E-06 1.72E-06 1.72E-06 1.72E-06 l
i P-32 2.36E-04 1.37E-05 8.95E-06 NO DATA NO DATA NO DATA 1.16E-05 CR-51 NO DATA NO DATA 1.69E-08 9.37E-09 3.84E-09 2.62E-06 3.75E-07 MN-54 NO DATA 6.39E-06 1.05E-06 NO DATA 1.59E-06 2.48E-04 8.35E-06 MN-56 NO DATA 2.12E-10 3.15E-11 NO DATA 2.24E-10 1.90E-06 7.18E-06 FE-55 4.18E-06 2.98E-06 6.93E-07 NO DATA NO DATA 1.55E-05 7.99E-07 FE-59 1.99E-06 4.62E-06 1.79E-06 NO DATA NO DATA 1.91E-04 2.23E-05 CO-58 NO DATA 2.59E-07 3.47E-07 NO DATA NO DATA 1.68E-04 1.19E-05 :;; j CO-60 NO DATA 1.89E-06 2.48E-06 NO DATA NO DATA 1.09E-03 3.2.4E-05 l-NI-63 7.25E-05 5.43E-06 2.47E-06 NO DATA NO DATA 3.84E-05 1.77E-06 l l NI-65 2.73E-10 3.66E-11 1.59E-11 NO DATA NO DATA 1.17E-06 4.59E-06 l 1.39E-06 7.68E-06 ! CU-64 NO DATA 2.54E-10 1.06E-10 NO DATA 8.01E-10 ZN-65 4.82E-06 1.67E-05 7.80E-06 NO DATA 1.08E-05 1.55E-04 5.83E-06 ZN-69 6.04E-12 1.15E-11 8.07E-13 NO DATA 7.53E-12 1.98E-07 3.56G08 BR-83 NO DATA NO DATA 4.30E-08 NO DATA NO DATA NO DATA LT E-24** BR-84 NO DATA NO D'ATA 5.41E-08 NO DATA NO DATA NO DATA LT E-24 BR-85 NO DATA NO DATA 2.29E-09 NO DATA NO DATA NO DATA LT E-24 RB-86 NO DATA 2.38E-05 1.05E-05 NO DATA NO DATA NO DATA 2.21E-06 f I RB-88 NO DATA 6.82E-08 3.40E-08 NO DATA NO DATA NO DATA 3.65E-15 RB-89 NO DATA 4.40E-08 2.91E-08 NO DATA NO DATA NO DATA 4.22E-17 i SR-89 5.43E-05 NO DATA 1.56E-06 NO DATA NO DATA 3.02E-04 4.64E-05 SR-90 1.35E-02 NO DATA 8.35E-04 NO DATA NO DATA 2.06E-03 9.56E-05 l l p i t 'g CLINTON-1 3-38 Rev.1-11/85
i g CPS-0DCM , ( l j Table 3.5-3 (continued) {
!'O "a^t^r o" noss r^croas rox rzz" - cor^1). !
(mrem per pCi inhaled) l NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI-
.SR-91 1.10E-08 NO DATA 4.39E-10 NO DATA NO DATA 7.59E-06 3.24E-05 SR-92 1.19E-09 NO DATA 5.08E-11 NO DATA NO DATA 3.43E-06 1.49E-05 Y-90 3.73E-07 NO DATA 1.00E-08 NO DATA NO DATA 3.66E-05 6.99E-05 Y-91m 4.63E-11 NO DATA 1.77E-12 NO DATA NO DATA 4.00E-07 3.77E-09 Y-91 8.26E-05 NO DATA 2.21E-06 NO DATA NO DATA 3.67E-04 5.11E-05 Y-92 1.84E-09 NO DATA 5.36E-11 NO DATA NO DATA 3.35E-06 2.06E-05 Y-93 1.69E-08 NO DATA 4.65E-10 NO DATA NO DATA 1.04E-05 7.24E-05 ZR-95 1.82E-05 5.73E-06 3.94E-06 NO DATA 8.42E-06 3.36E-04 1.86E-05 ZR-97 1.72E-08 3.40E-09 1.57E-09 NO DATA 5.15E-09 1.62E-05 7.88E-05 l NB-95 2.32E-06 1.29E-06 7.08E-07 NO DATA 1.25E-06 9.39E-05 1.21E M0-99 NO DATA 2.11E-08 4.03E-09 NO DATA 5.14E-08 1.92E-05 3.36E-05 TC-99m 1.73E-13 4.83E-13 6.24E-12 NO DATA 7.20E-12 1.44E-07 7.66E-07 TC-101 7.40E-15 1.05E-14 1.03E-13 NO DATA 1.90E-13 8.34E-08 1.09E-16 l RU-103 2.63E-07 NO DATA 1.12E-07 NO DATA 9.29E-07 9.79E-05 1.36E-05 RU-105 1.40E-10 NO DATA 5.42E-11 NO DATA 1.76E-10 2.27E-06 1.13E-05 RU-106 '.23E-05 1 NO DATA 1.55E-06 NO DATA 2.38E-05 2.01E-03 1.20E-04 l AG1-10m 1.73E-06 1.64E-06 9.99E-07 NO DATA 3.13E-06 8.44E-04 3.41E-05 TE-125m 6.10E-07 2.80E-07 8.34E-08 1.75E-07 NO DATA 6.70E-05, 9.38E-06 TE-127m 2.25E-06 1.02E-06 2.73E-07 5.48E-07 8.17E-06 2.07E-04 1.99E-05 TE-127 2.51E-10 1.14E-10 5.52E-11 1.77E-10 9.10E-10 1.40E-06 1.01E-05 TE-129m 1.74E-06 8.23E-07 2.81E-07 S.72E-07 6.49E-06 2.47E-04 5.06E-05
( TE-129 8.87E-12 4.22E-12 2.20E-12 6.48E-12 3.32E-11 4.12E-07 2.02E-07 TE-131m 1.23E-08 7.51E-09 5.03E-09 9.06E-09 5.49E-08 2.97E-05 7.76E-05 TE-131 1.97E-12 1.04E-12 6.30E-13 1.55E-12 7.72E-12 2.92E-07 1.89E-09 1 1 1O CLINTON-I 3-39 Rev.5-2/89 _ _ _ _ _ _ - - _ _ _ - - _ - - _ - - - - _ - - - - - - - - - - - - - - - _ - - - - - - - - - - - J
CPS-0DCM Table 3.5-3 (continued)
) INHALATION DOSE FACTORS FOR TEEN - (DFAt )a (mrem per pCi inhaled)
NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI 1 TE-132 4.50E-08 3.63E-08 2.74E-08 3.07E-08 2.44E-07 5.61E-05 5.79E-05 I-130 7.80E-07 2.24E-06 8.96E-07 1.86E-04 3.44E-06 NO DATA 1.14E-06 I-131 4.43E-06 6.14E-06 3.30E-06 1.83E-03 1.05E-05 NO DATA 8.11E-07 I-132 1.99E-07 5.47E-07 1.97E-07 1.89E-05 8.65E-07 NO DATA 1.59E-07 I-133 1.52E-06 2.56E-06 7.78E-07 3.65E-04 4.49E-06 NO DATA 1.29E-06 I-134 1.11E-07 2.90E-07 1.05E-07 4.94E-06 4.58E-07 NO DATA 2.55E-09 I-135 4.62E-07 1.18E-06 4.36E-07 7.76E-05 1.86E-06 NO DATA 8.69E-07 CS-134 6.28E-05 1.41E-04 6.86E-05 NO DATA 4.69E-05 1.83E-05 1.22E-06 CS-136 6.44E-06 2.42E-05 1.71E-05 NO DATA 1.38E-05 2.22E-06 1.36E-06 CS-137 8.38E-05 1.06E-04 3.89E-05 NO DATA 3.80E-05 1.51E-05 1.06E-06 CS-138 5.82E-08 1.07E-07 5.58E-08 NO DATA 8.28E-08 9.84E-09 3.38E-11 BA-139 1.67E-10 1.18E-13 4.87E-12 NO DATA 1.11E-13 8.08E-07 8.06E-07 l O V BA-140 6.84E-06 8.38E-09 4.40E-07 NO DATA 2.85E-09 2.54E-04 2.86E-05 BA-141 1.78E-11 1.32E-14 5.93E-13 NO DATA 1.23E-14 4.11E-07 9.33E-14 BA-142 4.62E-12 4.63E-15 2.84E-13 NO DATA 3.92E-15 2.39E-07 5.99E-20 LA-140 5.99E-08 2.95E-08 7.82E-09 NO DATA NO DATA 2.68E-05 6.09E-05 LA-142 1.20E-10 5.31E-11 1.32E-11 NO DATA NO DATA 1.27E-06 1.50E-06 CE-141 3.55E-06 2.37E-06 2.71E-07 NO DATA 1.11E-06 7.67E-05 , 1.58E-05 CE-143 3.32E-08 2.42E-08 2.70E-09 NO DATA 1.08E-08 1.63E-05 3.19E-05 CE-144 6.11E-04 2.53E-04 3.28E-05 NO DATA 1.51E-04 1.67E-03 1.08E-04 PR-143 1.67E-06 6.64E-07 8.28E-08 NO DATA 3.86E-07 6.04E-05 2.67E-05 PR-144 5.37E-12 2.20E-12 2.72E-13 NO DATA 1.26E-12 2.19E-07 2.94E-14 ND-147 9.83E-07 1.07E-06 6.41E-08 NO DATA 6.28E-07 4.65E-05 2.28E-05 W-187 1.50E-09 1.22E-09 4.29E-10 NO DATA NO DATA 5.92E-06 2.21E-05 NP-239 4.23E-08 3.99E-09 2.21E-09 NO DATA 1.25E-08 8.11E-06 1.65E-05 f
- 3.52 X 10-06 A ** Less than 10-24 q V
CLINTON-I 3-40 Rev.5-2/89
CPS-0DCM j l Table 3.5-4 l ] INHALATION DOSE FACTORS FOR ADULT - (DFA (mrem per pCi inhaled) f ), NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI H-3 NO DATA 1.58E-07 1.58E-07 1.58E-07 1.58E-07 1.58E-07 1.58E-07 C-14 2.27E-06* 4.26E-07 4.26E-07 4.26E-07 4.26E-07 4.26E-07 4.26E-07 NA-24 1.28E-06 1.28E-06 1.28E-06 1.28E-06 1.28E-06 1.28E-06 1.28E-06 P-32 1.65E-04 9.64E-06 6.26E-06 NO DATA NO DATA NO DATA 1.08E-05 CR-51 NO DATA NO DATA 1.25E-08 7.44E-09 2.85E-09 1.80E-06 4.15E-07 MN-54 NO DATA 4.95E-06 7.87E-07 NO DATA 1.23E-06 1.75E-04 9.67E-06 MN-56 NO DATA 1.55E-10 2.29E-11 NO DATA 1.63E-10 1.18E-06 2.53E-06 FE-55 3.07E-06 2.12E-06 4.93E-07 NO DATA NO DATA 9.01E-06 7.54E-07 FE-59 1.47E-06 3.47E-06 1.32E-06 NO DATA NO DATA 1.27E-04 2.35E-05 C0-58 NO DATA 1.98E-07 2.59E-07 NO DATA NO DATA 1.16E-04 1.33E-05 ' CO-60 NO DATA 1.44E-06 1.85E-06 NO DATA NO DATA 7.46E-04 3.56E-05 NI-63 5.40E-05 3.93E-06 1.81E-06 NO DATA NO DATA 2.23E-05 1.67E-06 O V NI-65 1.92E-10 2.62E-11 1.14E-11 NO DATA NO DATA 7.00E-07 1.54E-06 } CU-64 NO DATA 1.83E-10 7.69E-11 NO DATA 5.78E-10 8.48E-07 6.12E-06 ' ZN-65 4.05E-06 1.29E-05 5.82E-06 NO DATA 8.62E-06 1.08E-04 6.68E-06 ZN-69 4.23E-12 8.14E-12 5.65E-13 NO DATA 5.27E-12 1.15E-07 2.04E-09 BR-83 NO DATA NO DATA 3.01E-08 NO DATA NO DATA NO DATA 2.90E-08 BR-84 NO DATA NO DATA 3.91E-08 NO DATA NO DATA NO DATA 2.05E-13 BR-85 NO DATA NO DATA 1.60E-09 NO DATA NO DATA NO DATA LT E-24** RB-86 NO DATA 1.69E-05 7.37E-06 NO DATA NO DATA NO DATA 2.08E-06 RB-88 NO DATA 4.84E-08 2.41E-08 NO DATA NO DATA NO DATA 4.18E-19 RB-89 NO DATA 3.20E-08 2.12E-08 NO DATA NO DATA NO DATA 1.16E-21 SR-89 3.80E-05 NO DATA 1.09E-06 NO DATA NO DATA 1.75E-04 4.37E-05 SR-90 1.24E-02 NO DATA 7.62E-04 NO DATA NO DATA 1.20E-03 9.02E-05 O CLINTON-I 3-41 Rev.5-2/89
1 l CPS-0DCM 4
, 3 ,~i 1
Table 3.5-4 (continued) INHALATION DOSE FACTORS FOR ADULT - (DFAf ) (mrem per pCi inhaled)
'NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI I SR-91 7.74E-09 NO DATA 3.13E-10 NO DATA NO DATA 4.56E-06 2.39E-05 SR-92 8.43E-10 NO DATA 3.64E-11 NO DATA NO DATA 2.06E-06 5.38E-06 Y-90 2.61E-07 NO DATA 7.01E-09 NO DATA NO DATA 2.12E-05 6.32E-05 ~! Y-91m 3.26E-11 NO DATA 1.27E-12 NO DATA NO DATA 2.40E-07 1.66E-10 Y-91 5.78E-05 NO DATA 1.55E-06 NO DATA NO DATA 2.132-04 4.81E-05 Y-92 1.29E-09 NO DATA 3.77E-11 NO DATA NO DATA 1.96E-06 9.19E-06 i
Y-93 1.18E-08 NO DATA 3.26E-10 NO DATA NO DATA 6.06E-06 5.27E-05 ZR-95 1.34E-05 4.30E-06 2.91E-06 NO DATA 6.77E-06 2.21E-04 1.88E-05 ZR-97 1.21E-08 2.45E-09 1.13E-09 NO DATA 3.71E-09 9.84E-06 6.54E-05 NB-95 1.76E-06 9.77E-07 5.26E-07 NO DATA 9.67E-07 6.31E-05 1.30E-05 C
~
Cs MO-99 NO DATA 1.51E-08 2.87E-09 NO DATA 3.64E-08 1.14E-05 3.10E-05 TC-9,9m 1.29E-13 3.64E-13 4.63E-12 NO DATA 5.52E-12 9.55E-08 5.20E-07
)
TC-101 5.22E-15 7.52E-15 7.38E-14 NO DATA 1.35E-13 4.99E-08 1.36E-21 l RU-103 1.91E-07 NO DATA 8.23E-08 NO DATA 7.29E-07 6.31E-05 1.38E-05 RU-105 9.88E-11 NO DATA 3.89E-11 NO DATA 1.27E-10 1.37E-06 6.02E-06 RU-106 8.64E-06 NO DATA 1.09E-06 NO DATA 1.67E-05 1.17E-03 1.14f'04 AG-110m 1.35E-06 1.25E-06 7.43E-07 NO DATA 2.46E-06 5.79E-04 3.78E-05 TE-125m 4.27E-07 1.98E-07 5.84E-08 1.31E-07 1.55E-06 3.92E-05 8.83E-06 TE-127m 1.58E-06 7.21E-07 1.96E-07 4.11E-07 5.72E-06 1.20E-04 1.87E-05 TE-127 1.75E-10 8.03E-11 3.87E-11 1.32E-10 6.37E-10 8.14E-07 7.17E-06 TE-129m 1.22E-06 5.84E-07 1.98E-07 4.30E-07 4.57E-06 1.45E-04 4.79E-05 TE-129 6.22E-12 2.99E-12 1.55E-12 4.87E-12 2.34E-11 2.42E-07 1.96E-08
' 6.88E-09 3.86E-08 1.82E-05 6.95E-05 TE-131m 8.74E-09 5.45E-09 3.63E-09 TE-131 1.39E-12 7.44E-13 4.49E-13 1.17E-12 5.46E-12 1.74E-07 2.30E-09 TE-132 3.25E-08 2.69E-08 2.02E-08 2.37E-08 1.82E-07 3.60E-05 6.37E-05 I-130 5.72E-07 1.68E-06 6.60E-07 1.42E-04 2.61E-06 NO DATA 9.61E-07 I-131 3.15E-06 4.47E-06 2.56E-06 1.49E-03 7.66E-06 NO DATA 7.85E-07 O
CLINTON-I 3-42 Rev.1-11/85
CPS-0DCM J 1 Table 3.5-4 (continued) [] INHALATION DOSE FACTORS FOR ADULT - (DFA 1 ), (mrem per pCi inhaled)
]
NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI I-132 1.45E-07 4.07E-07 1.45E-07 1.43E-05 6.48E-07 NO DATA 5.08E-08 I-133 1.08E-06 1.85E-06 5.65E-07 2.69E-04 3.23E-06 NO DATA 1.11E-06 I-134 8.05E-08 2.16E-07 7.69E-08 3.73E-06 3.44E-07 NO DATA 1.26E-10 I-135 3.35E-07 8.73E-07 3.21E-07 5.60E-05 1.39E-06 NO DATA 6.56E-07 CS-134 4.66E-05 1.06E-04 9.10E-05 NO DATA 3.59E-05 1.22E-05 1.30E-06 CS-136 4.88E-06 1.83E-05 1.38E-05 NO DATA 1.07E-05 1.50E-06 1.46E-06 CS-137 5.98E-05 7.76E-05 5.35E-05 NO DATA 2.78E-05 9.40E-06 1.05E-06 CS-138 4.14E-08 7.76E-08 4.05E-08 NO DATA 6.00E-08 6.07E-09 2.33E-13 BA-139 1.17E-10 8.32E-14 3.42E-12 NO DATA 7.78E-14 4.70E-07 1.12E-07 BA-140 4.88E-06 6.13E-09 3.21E-07 NO DATA 2.09E-09 1.59E-04 2.73E-05 ; BA-141 1.25E-11 9.41E-15 4.20E-13 NO DATA 8.75E-15 2.42E-07 1.45E-17 BA-142 3.29E-12 3.38E-15 2.07E-13 NO DATA 2.86E-15 1.49E-07 1.96E-26 i LA-140 4.30E-08 2.17E-08 5.73E-09 NO DATA NO DATA 1.70E-05 5.73E-05 l LA-142 8.54E-11 3.88E-11 9.65E-12 NO DATA NO DATA 7.91E-07 2.64E-07 CE-141 2.49E-06 1.69E-06 1.91E-07 NO DATA 7.83E-07 4.52E-05 1.50E-05 CE-143 2.33E-08 1.72E-08 1.91E-09 .NO DATA 7.60E-09 9.97E-06 2.83E-05 CE-144 4.29E-04 1.79E-04 2.30E-05 NO DATA 1.06E-04 9.72E-04 1.02E-04 PR-143 1.17E-06 4.69E-07 5.80E-08 NO DATA 2.70E-07 3.51E-05 2.50E-05 PR-144 3.76E-12 1.56E-12 1.91E-13 NO DATA 8.81E-13 1.27E-07 2.69E-18 ND-147 6.59E-07 7.62E-07 4.562-08 NO DATA 4.45E-07 2.76E-05 2.16E-05 W-187 1.06E-09 8.65E-10 3.10E-10 NO DATA NO DATA 3.63E-06 1.94E-05 NP-239 2.87E-08 2.82E-09 1.55E-09 NO DATA 8.75E-09 4.70E-06 1.49E-05
- 2.27 X 10-06
** Less than 10-24 0V CLINTON-I 3-43 Rev.5-2/89
_ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ ____a
~
CPS-0DCM >
]
l TABLE 3.5-5 i l s, ~) GROUND PLANE DOSE FACTORS - DFG t 1 (mrem /hr per pCi/m2) l ELEMENT TOTAL BODY SKIN ; i E-3 0.0 0.0 I C-14 0.0 0.0 1 NA-24 2.50E-08* 2.90E-08' l P-32 0.0 0.0 CR-51 2.20E-10 2.60E-10 MN-54 5.80E-09 6.80E-09 MN-56 1.10E-08 1.30E-08 FE-55 0.0 0.0 FE-59 8.00E-09 9.40E-09 CO-58 7.00E-09 8.20E-09 , CO-60 1.70E-08 2.00E-08 > NI-63 0.0 ^ 0.0 NI-65 3.70E-09 4.30E-09 CU-64 1.50E-09 1.70E-09 ZN-65 4.00E-09 4.60E-09 ZN-69 0.0 0.0 BR-83 6.40E-11 9.30E-ll i BR-84 ' 1.20E-08 1.40E-08 I () (- BR-85 0.0 0.0 i RB-86 6.30E-10 7.20E-10 ' l RB-88 3.50E-09 4.00E-09 RB-89 1.50E-08 1.80E-08 SR-89 5.60E-13 6.50E-13 SR-91 . 7.10E-09 8.30E-09 SR-92 9.00E-09 1.00E-08 Y-90 2.20E-12 2.60E-12 Y-91m 3 80E-09 4.40E-09 Y-91 ~~ 1.40E-11 2.70E-ll
,Y-92 1.60E-09 1.90E-09 !
Y-93 5.70E-10 7.80E-10 I ZR-95 5.00E-09 5.80E 09 ZR-97 5.50E-09 ~- 6.40E-09 NB-95 5.10E-09 6.00E-09 MO-99 1.90E-09 2.20E-09 TC-99m 9.60E-10 1.10E-09 TC-101 2.70E-09 3.00E-09 RU-103 3.60E-09 4.20E-09 RU-105 4.50E-09 5.10E-09 RU-106 1.50E-09 1.80E-09
- AG-110m 1.80E-08 2.10E-08 I
lO CLINTON-I 3-44 Rev.5-2/89 l _ - _ _ _ _ _ _ _ _ - - - - - - _ - - - - -- --- - 1
L CPS-0DCM I l: L Table 3.5-5 (Continued)' () , GROUND PLANE DOSE FACTORS - DFG 1 (mrem /hr per pCi/m ) 2 ELEMENT. TOTAL BODY SKIN TE-125m 3.50E-11 4.80E-11 TE-127m 1.10E-12 1.30E-12 TE-127 1.00E-ll 1.10E-ll
,.TE-129m 7.70E-10 9.00E-10 TE-129 7.10E-10 8.40E-10 TE-131m 8.40E-09 9.90E-09 TE-131 2.20E-09 2.60E-06 TE-132 1.70E-09 2.00E-09 I-130 1.40E-08 1.70E-08 I-131 2.80E-09 3.40E-09 I-132 1.70E-08 2.00E-08 I-133 -
3.70E-09 4.50E-09 I-134 1.60E-08 1.90E-08 I-135 1.20E-08 1.40E-08 l.20E-08 CS-134 1.40E-08 CS-136 1.50E-08 1.70E-08 CS-137 4.20E-09 4.90E-09 CS-138 2.10E-08 2.40E-08 BA-139 2.40E-09 2.70E-09 (^T BA-140 2.10E-09 2.40E-09 (_/ 'BA-141 4.30E-09 4.90E-09 l
'BA-142 7.90E-09 9.00E-09 LA-140 1.50E-08 1.70E-08 LA-142 1.50E-08 1.80E-08 CE-141 5.50E-10 6.20E-10 1 CE-143 . 2.20E-09 2.50E-09
CE-144 3.20E-10 3.70E-10 PR-143 0.0 0.0 PR-144 Z.00E-10 2.30E-lO ND-147 1.00E-09 1.20E-09 W-187 3.10E-09 3.60E-09 NP-239 9.50E-10 1.10E-09 l
*2.50 X 10-08 l
() CLINTON-I 3-45 Rev.5-2/89
CPS-0DCM O TABLE 3.5-6 INGESTION DOSE FACTORS FOR INFANT - (DFLf )a (mrem per pCi ingested) I BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LL1
; NUCLIDE 3.08E-07 3.08E-07 3.08E-07 3.08E-07 ~3.08E-07 3.08E-07 I H-3 NO DATA C-14 2.37E-05* 5.06E-06 5.06E-06 5.06E-06 5.06E-06 5.06E-06 5.06E-06 l 1.01E-05 1.01E-05 1.01E-05 1.01E-05 1.01E-05 NA-24 1.01E-05 1.01E-05 j
P-32 1.70E-03 1.00E-04 6.59E-05 NO DATA NO DATA NO DATA 2.30E-05 l 1.41E-08 9.20E-09 2.01E-09 1.79E-08 4.11E-07 CR-51 NO DATA NO DATA HN-54 NO DATA 1.99E-05 4.51E-06 NO DATA 4.41E-06 NO DATA 7.31E-06 MN-56 NO DATA 8.18E- 07 1.41E-07 NO DATA 7.03E-07 NO DATA 7.43E-05 FE-55 1.39E-05 8.98E-06 2.40E-06 NO DATA NO DATA 4.39E-06 1.14E-06 FE-59 3.08E-05 5.38E-05 2.12E-05 NO DATA NO DATA- 1.59E-05 2.57E-05 CO-58 NO DATA 3.60E-06 8.98E-06 NO DATA NO DATA NO DATA 8.97E-06 l NO DATA 2.57E-05 CO-60 NO DATA 1.08E-05 2.55E-05 NO DATA NO DATA 9 NI-63 6.34E-04 3.92E-05 2.20E-05 NO DATA NO DATA NO DATA 1.95E-06 NI-65 4.70E-06 5.32E-07 2.42E-07 NO DATA NO DATA NO DATA 4.05E-05 CU-64 NO DATA 6.09E-07 2.82E-07 NO DATA 1.03E-06 NO DATA 1.25E-05 ZN-65 1.84E-05 6.31E-05 2.91E-05 NO DATA 3.06E-05 NO DATA 5.33E-05 1.68E-07 1.25E-08 NO DATA 6.98E-08 NO DATA 1.37E;05 ZN-69 9.33E-08 BR-83 NO DATA NO DATA 3.63E-07 NO DATA NO DATA NO DATA LT E-24** h3-84 NO DATA NO DATA 3.82E-07 NO DATA NO DATA NO DATA LT E-24 NO DATA l'O DATA 1.94E-08 NO DATA NO DATA NO DATA LT E-24 BR-85 RB-86 NO DATA 1.70E-04 8.40E-05 NO DATA NO DATA NO DATA 4.34E-06 RB-88 NO DATA 4.98E-07 2.73E-07 NO DATA NO DATA NO DATA 4.85E-07 RB-89 NO DATA 2.86E-07 1.97E-07 NO DATA NO DATA NO DATA 9.74E-08 l SR-89 2.51E-03 NO DATA 7.20E-05 NO DATA NO DATA NO DATA 5.16E-05 SR-90 1.85E-02 NO DATA 4.71E-03 NO DATA NO DATA NO DATA 2.31E-04 i SR-91 5.00E-05 NO DATA 1.81E-06 NO DATA NO DATA NO DATA 5.92E-05 ' SR-92 1.92E-05 NO DATA 7.13E-07 NO DATA NO DATA NO DATA 2.07E-04
! Y-90 8.69E-08 NO DATA 2.33E-09 NO DATA NO DATA NO DATA 1.20E-04 O
CLINTON-I 3-46 Rev.1-11/85
~~
CPS-0DCM O , TABLE 3.5-6 (continued) INGESTION DOSE FACTORS FOR INFANT - (DFL 1 ), (mrem per pCi ingested) BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI NUCLIDE i Y-91m 8.10E-10 NO DATA '2. 76E- 11 NO DATA NO DATA NO DATA 2.70E-06 Y-91 1.13E-06 NO DATA 3.01E-08 NO DATA NO DATA NO DATA 8.10E-05 Y-92 7.65E-09 NO DATA 2.15E-10 NO DATA NO DATA NO DATA 1.46E-04 i. Y-93 2.43E-08 NO DATA 6.62E-10 NO DATA NO DATA NO DATA 1.92E-04 ZR-95 2.06E-07 5.02E-08 3.56E-08 NO DATA 5.41E-08 NO DATA 2.50E-05 l 2.56E-09 NO DATA 1.62E-04 ZR-97 1.48E-08 2.54E-09 1.16E-09 NO DATA h NB-95 4.20E-08 1.73E-08 1.00E-08 NO DATA 1.24E-08 NO DATA 1.46E-05 MD-99 NO DATA 3.40E-05 6.63E-06 NO DATA 5.08E-05 NO DATA 1.12E-05 TC-99m 1.92E-09 3.96E-09 5.10E-08 NO DATA 4.26E-08 2.07E-09 1.15E-06 TC-101 2.27E-09 2.86E-09 2.83E-08 NO DATA 3.40E-08 1.56E-09 4.86E-07 RU-103 1.48E-06 NO DATA 4.95E-07 NO DATA 3.08E-06 NO DATA 1.80E-05 RU-105 1.36E-07 NO DATA 4.58E-08 NO DATA 1.00E-06 NO DATA 5.41E-05 RU-106 2.41E-05 NO DATA 3.01E-06 NO DATA 2.85,E-05 NO DATA 1.83E-04 AG-110m 9.96E-07 7.27E-07 4.81E-07 NO DATA 1.04E-06 NO DATA 3.77E-05 TE-125m 2.33E-05 7.79E-06 3.15E-06 7.84E-06 NO DATA NO DATA 1.11E-05 TE-127m 5.85E-05 1.94E-05 7.08E-06 1.69E-05 1.44E-04 NO DATA 2.36E-05 TE-127 1.00E-06 3.35E-07 2.15E-07 8.14E-07 2.44E-06 NO DATA 2.10E-05 TE-129m 1.00E-04 3.43E-05 1.54E-05 3.84E-05 2.50E-04 NO DATA 5.97E-05 TE-129 2.84E-07 9.79E-08 6.63E-08 2.38E-07 7.07E-07 NO DATA 2.27E-05 TE-131m 1.52E-05 6'.12E-06 5.05E-06 1.24E-05 4.21E-05 NO DATA 1.03E-04 TE-131 1.76E-07 6.50E-08 4.94E-08 1.57E-07 4.50E-07 NO DATA 7.11E-06 i TE-132 2.08E-05 1.03E-05 9.61E-06 1.52E-05 6.44E-05 NO DATA 3.81E-05 I-130 6.00E-06 1.32E-05 5.30E-06 1.48E-03 1.45E-03 NO DATA 2.83E-06 I-131 3.59E-05 4.23E-05 1.86E-05 1.39E-02 4.94E-05 NO DATA 1.51E-06 I-132 1.66E-06 3.37E-06 1.20E-06 1.58E-04 3.76E-06 NO DATA 2.73E-06 I-133 1.25E-05 1.82E-05 5.33E-06 3.31E-03 2.14E-05 NO DATA 3.08E-06 I-134 8.69E-07 1.78E-06 6.33E-07 4.15E-05 1.99E-06 NO DATA 1.84E-06 CLINTON-I 3-47 Rev.1-11/85
l l CPS-0DCM j i 3 ; 1
) 'I TABLE 3.5-6 (continued)
INGESTION DOSE FACTORS FOR INFANT - (DFLf )a ; (mrem per pCi ingested) I NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI
! I-135 3.64E-06 7.24E-06 2.64E-06 6.49E-04 8.07E-06 'NO DATA 2.62E-06 CS-134 3.77E-04 7.03E-04 7.10E-05 NO DATA 1.81E-04 7.42E-05 1.91E-06 ! CS-136 4.59E-05 1.35E-04 5.04E-05 NO DATA 5.38E-05 1.10E-05 2.05E-06 i CS-137 5.22E-04 6.11E-04 4.33E-05 F0 DATA 1.64E-04 6.64E-05 1.91E-06 CS-138 4.81E-07 7.82E-07 3.79E-07 NO DATA 3.90E-07 6.09E-08 1.25E-06 BA-139 8.81E-07 5.84E-10 2.55E-08 NO DATA 3.51E-10 3.54E-10 5.58E-05 l ,
i BA-140 1.71E-04 1.71E-07 8.81E-06 NO DATA 4.06E-08 1.05E-07 4.20E-05 BA-141 4.25E-07 2.91E-10 1.34E-08 NO DATA 1.75E-10 1.77E-10 5.19E-06 BA-142 1.84E-07 1.53E-10 9.06E-09 NO DATA 8.81E-11 9.26E-11 7.59E-07 LA-140 2.11E-08 8.32E-09 2.14E-09 NO DATA NO DATA NO DATA 9.77E-05 = LA-142 1.10E-09 4.04E-10 9.67E-11 NO DATA NO DATA NO DATA 6.86E-05 CE-141 7.87E-08 4.80E-08 5.65E-09 NO DATA 1.48E-08 NO DATA 2.48E-05 CE-143 1.48E-08 9.82E-06 1.12E-09 NO DATA 2.86E-09 NO DATA 5.73E-05 CE-144 2.98E-06 1.22E-06 1.67E-07 NO DATA 4.93E-07 NO DATA 1.71E-04 PR-143 8.13E-08 3.04E-08 4.03E-09 NO DATA 1.13E-08 NO DATA 4.29E-05 PR-144 2.74E-10 1.06E-10 1.38E-11 NO DATA 3.84E-11 NO DATA 4.93f'06 ND-147 5.53E-08 5.68E-08 3.48E-09 NO DATA 2.19E-08 NO DATA 3.60E-05
; W-137 9.03E-07 6.28E-07 2.17E-07 NO DATA NO DATA NO DATA 3.69E-05 NP-239 1.11E-08 9.93E-10 5.61E-10 NO DATA 1.98E-09 NO DATA 2.87E-05 -05
- 2.37 X 10
- ** Less than 10-24 i
p I CLINTON-I 3-48 Rev.1-ll/85
CPS-0DCM i TABLE 3.5-7 g ; (,j INGESTION DOSE FACTORS FOR CHILD - (DFLt )a (mrem per pCi ingested) i NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI H-3 NO DATA 2.03E-07 2.03E-07 2.03E-07 2.03E-07 2.03E-07 2.03E-07 C-14 1.21E-05* 2.42E-06 2.42E-06 2.42E-06 2.42E-06 2.42E-06 2.42E-06 NA-24 5.80E-06 5.80E-06 5.80E-06 5.80E-06 5.80E-06 5.80E-06 5.80E-06 P-32 8.25E-04 3.86E-05 3.18E-05 NO DATA NO DATA NO DATA 2.28E-05 CR-51 NO DATA NO DATA 8.90E-09 4.94E-09 1.35E-09 9.02E-09 4.72E-07 MN-54 NO DATA 1.07E-05 2.85E-06 NO DATA 3.00E-06 NO DATA 8.98E-06 MN-56 NO DATA 3.34E-07 7.54E-08 NO DATA 4.04E-07 NO DATA 4.84E-05 FE-55 1.15E-05 6.10E-06 1.89E-06 NO DAT6 NO DATA 3.45E-06 1.13E-06 FE-59 1.65E-05 2.67E-05 1.33E-05 NO DATA NO DATA 7.74E-06 2.78E-05 CO-58 NO DATA 1.80E-06 5.51E-06 NO DATA NO DATA NO DATA 1.05E-05 CO-60 NO DATA 5.29E-06 1.56E-05 NO DATA NO DATA NO DATA 2.93E-05 NI-63 5.38E-04 2.88E-05 1.83E-05 NO DATA NO DATA NO DATA 1.94E-06 NI-65 2.22E-06 2.09E-07 1.22E-07 NO DATA NO DATA NO DATA 2.56E-05 CU-64 NO DATA 2.45E-07 1.48E-07 NO DATA 5.92E-07 NO DATA 1.15E-05 ZN-65 1.37E-05 3.65E-05 2.27E-05 NO DATA 2.30E-05 NO DATA 6.41E-06 ZN-69 4.38E-08 6.33E-08 5.85E-09 NO DATA 3.84E-08 NO DATA 3.99E-06 BR-83 NO DATA NO DATA 1.71E-07 NO DATA NO DATA NO DATA LT E-24** BR-84 NO DATA NO DATA 1.98E-07 NO DATA NO DATA NO DATA , LT E-24 BR-85 NO DATA NO DATA 9.12E-09 NO DATA NO DATA NO DATA LT E-24 RB-86 NO DATA 6.70E-05 4.12E-05 NO DATA NO DATA NO DATA 4.31E-06 RB-88 NO DATA 1.90E-07 1.32E-07 NO DATA NO DATA NO DATA 9.32E-09 RB-89 NO DATA 1.17E-07 1.04E-07 NO DATA NO DATA NO DATA 1.02E-09 SR-89 1.32E-03 NO DATA 3.77E-05 NO DATA NO DATA NO DATA 5.11E-05 SR-90 1.70E-02 NO DATA 4.31E-03 NO DATA NO DATA NO DATA 2.29E-04 SR-91 2.40E-05 NO DATA 9.06E-07 NO DATA NO DATA NO DATA 5.30E-05 SR-92 9.03E-06 NO DATA 3.62E-07 NO DATA NO DATA NO DATA 1.71E-04 Y-90 4.11E-08 NO DATA 1.10E-09 NO DATA NO DATA NO DATA 1.17E-04 CLINTON-I 3-49 Rev.5-2/89
I CPS-ODC21 ! l TABLE 3.5-7 (continued) (j, INGESTION DOSE FACTORS FOR CHILD - (DFLf )a (mrem per pCi ingested) NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI Y-91m 3.82E-10 NO DATA 1.39E-11 NO DATA NO DATA NO DATA 7.48E-07 Y-91 6.02E-07 NO DATA 1.61E-08 NO DATA NO DATA NO DATA 8.02E-05 Y-92 3.60E-09 NO DATA 1.03E-10 NO DATA NO DATA NO DATA 1.04E-04 i Y-93 1.14E-08 NO DATA 3.13E-10 NO DATA NO DATA NO DATA 1.70E-04 I ZR-95 1.16E-07 2.55E-08 2.27E-08 NO DATA 3.65E-08 NO DATA 2.66E-05 ZR-97 6.99E-09 1.01E-09 5.96E-10 NO DATA 1.45E-09 NO DATA 1.53E-04 l 1 NB-95 2.25E-08 8.76E-09 6.26E-09 NO DATA 8.23E-09 NO DATA 1.62E-05 ! M0-99 NO DATA 1.33E-05 3.29E-06 NO DATA 2.84E-05 NO DATA 1.10E-05 l TC-99m 9.23E-10 1.81E-09 3.00E-08 NO DATA 2.63E-08 9.19E-10 1.03E-06 , TC-101 1.07E-09 1.12E-09 1.42E-08 NO DATA 1.91E-08 5.92E-10 3.56E-09 (
\ ~
RU-103 RU-105 7.31E-07 6.45E-08 NO DATA NO DATA 2.81E-07 2.34E-08 NO DATA NO DATA 1.84E-06 5.67E-07 NO DATA NO DATA 1.89E-05 4.21E-05 L RU-106 1.17E-05 NO DATA 1.46E-06 NO DATA 1.58E-05 NO DATA 1.82E-04 AG-110m 5.39E-07 3.64E-07 2.91E-07 NO DATA 6.78E-07 NO DATA 4.33E-05 TE-125m 1.14E-05 3.09E-06 1.52E-06 3.20E-06 NO DATA NO DATA 1.10E-05 TE-127m 2.89E-05 7.78E-06 3.43E-06 6.91E-06 8.24E-05 NO DATA 2.34E-05 TE-127 4.71E-07 1.27E-07 1.01E-07 3.26E-07 1.34E-06 NO DATA ' 1.84E-05 TE-129m 4.87E-05 1.36E-05 7.56E-06 1.57E-05 1.43E-04 NO DATA 5.94E-05 l l TE-129 1.34E-07 3.74E-08 3.18E-08 9.56E-08 3.92E-07 NO DATA 8.34E-06 TE-131m 7.20E-06 2.49E-06 2.65E-06 5.12E-06 2.41E-05 NO DATA 1.01E-04 TE-131 8.30E-08 2.53E-08 2.47E-08 6.35E-08 2.51E-07 NO DATA 4.36E-07 l TE-132 1.01E-05 4.47E-06 5.40E-06 6.51E-06 4.15E-05 NO DATA 4.50E-05 I-130 2.92E-06 5.90E-06 3.04E-06 6.50E-04 8.82E-06 NO DATA 2.76E-06 ? I-131 1.72E-05 1.73E-05 9.83E-06 5.72E-03 2.84E-05 NO DATA 1.54E-06 I-132 8.00E-07 1.47E-06 6.76E-07 6.82E-05 2.25E-06 NO DATA 1.73E-06 I-133 5.92E-06 7.32E-06 2.77E-06 1.36E-03 1.22E-05 NO DATA 2.95E-06 () I-134 4.19E-07 7.78E-07 3.58E-07 1.79E-05 1.19E-06 NO DATA 5.16E-07 CLINTON-I 3-50 Rev.5-2/89 l _ _ _ _ _ - - - - _ ____-__-__ ___ - _ ___ --____-_-__- _ _ _ - _ _ _ - _ _ _ _ _ _ - - _ _ _ _ _ _ - _ - - _ _ _ . _ -__-__ _ _ -_J
r 1 1 ( CPS-0DCM l l l
'( TABLE 3.5-7 (continued) l INGESTION DOSE FACTORS FOR CHILD - (DFLf )a 1
(mrem per pCi ingested) 4 NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNC GI-LLI t
! I-135 1.75E-06 3.15E-06 1.49E-06 2.79E-04 4.83E-06 'NO DATA 2.40E-06 CS-134 2.34E-04 3.84E-04 8.10E-05 NO DATA 1.19E-04 4.27E-05 2.07E-06 l , CS-136 2.35E-05 6.46E-05 4.18E-05 NO DATA 3.44E-05 5.13E-06 2.27E-06 ; CS-137 3.27E-04 3.13E-04 4.62E-05 NO DATA 1.02E-94 3.67E-05 1.96E-06 CS-138 2.28E-07 3.17E-07 2.01E-07 NO DATA 2.23E-07 2.40E-08 1.46E-07 BA-139 4.14E-07 2.21E-10 1.20E-08 NO DATA 1.93E-10 1.30E-10 2.39E-05 }
BA-140 8.31E-05 7.28E-08 4.85E-06 NO DATA 2.37E-08 4.34E-08 4.21E-05 BA-141 2.00E-07 1.12E-10 6.51E-09 NO DATA 9.69E-11 6.58E-10 1.14E-07 i BA-142 8.74E-08 6.29E-11 4.88E-09 NO DATA 5.09E-11 3.70E-11 1.14E-09 j LA-140 1.01E-08 3.53E-09 1.10E-09 NO DATA NO DATA NO DATA 9.64E-05 ~ LA-142 5.24E-10 1.67E-10 5.23E-11 NO. DATA NO DATA NO DATA 3.31E-05 9 .CE-141 CE-143 8.97E-08 6.99E-09 1.98E-08 3.79E-06 2.94E-09 5.49E-10 NO DATA NO DATA 8.68E-09 1.59E-09 NO DATA NO DATA 2.47E-05 5.55E-05 CE-144 2.08E-06 6.51E-07 1.11E-07 NO DATA 3.61E-07 NO DATA 1.70E-04 PR-143 3.93E-08 1.18E-08 1.95E-09 NO DATA 6.39E-09 NO DATA 4.24E-05
~'
PR-144 1.29E-10 3.99E-11 6.49E-12 NO DATA 2.11E-11 NO DATA 8.59E-08 ND-147 2.79E-08 2.26E-08 1.75E-09 NO DATA 1.24E-08 NO DATA 3.58E.-05 W-187 4.29E-07 2.54E-07 1.14E-07 NO DATA NO DATA NO DATA 3.57E-05 l NP-239 5.25E-09 3.77E-10 2.65E-10 NO DATA 1.09E-09 NO DATA 2.79E-05
-05 *1.21 X 10 ** Less than 10-24 i
i
, 'm
( ) Vf CLINTON-I 3-51 Rev.1-11/85
l l l i CPS-0DCM TABLE 3.5-8 j INGESTION DOSE FACTORS FOR TEEN - (DFL.)a 1 (mrem per pCi ingested) i I NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG G1-LLI l H-3 NO DATA 1.06E-07 1.06E-07 1.06E-07 1.06E-07 1.06E-07 1.06E-07 i C-14 4.06E-06* 8.12E-07 8.12E-07 8.12E-07 8.12E-07 8.12E-07 8.12E-07
! NA-24 2.30E-06 2.30E-06 2.30E-06 2.30E-06 2.30E-06 2.30E-06 2.30E-06 ! P-32 2.76E-04 1.71E-05 1.07E-05 NO DATA NO DATA NO DATA 2.32E-05 ! CR-51 NO DATA NO DATA 3.60E-09 2.00E-09 7.89E-10 5.14E-09 6.05E-07 MN-54 NO DATA 5.90E-06 1.17E-06 NO DATA 1.76E-06 NO DATA 1.21E-05 l
i MN-56 NO DATA 1.58E-07 2.81E-08 NO DATA 2.00E-07 NO DATA 1.04E-05 FE-55 3.78E-06 2.68E-06 6.25E-07 NO DATA NO DATA 1.70E-06 1.16E-06 FE-59 5.87E-06 1.37E-05 5.29E-06 NO DATA NO DATA 4.32E-06 3.24E-05 l CO-58 NO DATA 9.72E-07 2.24E-06 NO DATA NO DATA NO DATA 1.34E-05 L CO-60 NO DATA 2.81E-06 6.33E-06 NO DATA NO DATA NO DATA 3.66E-05 9 NI-63 NI-65 1.77E-04 7.49E-07 1.25E-05 9.57E-08 6.00E-06 4.36E-08 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA 1.99E-06 5.19E-06 CU-64 NO DATA 1.15E-07 5.41E-08 NO DATA 2.91E-07 NO DATA 8.92E-06 ZN-65 5.76E-06 2.00E-05 9.33E-06 NO DATA 1.28E-05 NO DATA 8.47E-06
~'
ZN-69 1.47E-08 2.80E-08 1.96E-09 NO DATA 1.83E-08 NO DATA 5.16E-08
! BR-83 NO DATA NO DATA 5.74E-08 NO DATA NO DATA NO DATA LT E-24**
BR-84 NO DATA NO DATA 7.22E-08 NO DATA NO DATA NO DATA LT E-24 l BR-85 NO DATA NO DATA 3.05E-09 NO DATA NO DATA NO DATA LT E-24 RB-86 NO DATA 2.98E-05 1.40E-05 NO DATA NO DATA NO DATA 4.41E-06
, RB-88 NO DATA 8.52E-08 4.54E-08 NO DATA NO DATA NO DATA 7.30E-15 RB-89 NO DATA 5.50E-08 3.89E-08 NO DATA NO DATA NO DATA 8.43E-17 l SR-89 4.40E-04 NO DATA 1.26E-05 NO DATA NO DATA NO DATA 5.24E-05 SR-90 8.30E-03 NO DATA 2.05E-03 NO DATA NO DATA NO DATA 2.33E-04 SR-91 8.07E-06 NO DATA 3.21E-07 NO DATA NO DATA NO DATA 3.66E-05 SR-92 3.05E-06 NO DATA 1.30E-07 NO DATA NO DATA NO DATA 7.77E-05 l
l Y-90 1.37E-08 NO DATA 3.69E-10 NO DATA NO DATA NO DATA 1.13E-04
~p l
9 CLINTON-1 3-52 Rev.1-11/85
CPS-0DCM TABLE 3.5-8 (continued) h INGESTION DOSE FACTORS FOR TEEN - (DFL f ), I (mrem per pCi ingested) NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI Y-91m 1.29E-10 NO DATA 4.93E-12 NO DATA NO DATA NO DATA 6.09E-09 Y-91 2.01E-07 NO DATA 5.39E-09 NO DATA NO DATA NO DATA 8.24E-05 Y-92 1.21E-09 NO DATA 3.50E-11 NO DATA NO DATA NO DATA 3.32E-05
~
Y-93 3.83E-09 NO DATA 1.05E-10 NO DATA NO DATA NO DATA 1.17E-04 l ZR-95 4.12E-08 1.30E-08 8.94E-09 NO DATA 1.91E-08 NO DATA 3.00E-05 l ZR-97 2.37E-09 4.69E-10 2.16E-10 NO DATA 7.11E-10 NO DATA 1.27E-04 NB-95 8.22E-09 4.56E-09 2.51E-09 NO DATA 4.42E-09 NO DATA 1.95E-05 M0-99 NO DATA 6.03E-06 1.15E-06 NO DATA 1.38E-05 NO DATA 1.08E-05 TC-99m 3.32E-10 9.26E-10 1.20E-08 NO DATA 1.38E-08 5.14E-10 6.08E-07 TC-101 3.60E-10 5.12E-10 5.03E-09 NO DATA 9.26E-09 3.12E-10 8.75E-17 RU-103 2.55E-07 NO DATA 1.09E-07 NO DATA 8.99E-07 NO DATA 2.13E-05 RU-105 2.18E-08 NO DATA 8.46E-09 NO DATA 2.75E-07 NO DATA 1.76E-05 O RU-106 3.92E-06 NO DATA 4. 9 /:E-07 NO DATA 7.56E-06 NO DATA 1.88E-04 AG-110m 2.05E-07 1.94E-07 1.18E-07 NO DATA 3.70E-07 NO DATA 5.45E-05 TE-125m 3.83E-06 1.38E-06 5.12E-07 1.07E-06 NO DATA NO DATA 1.13E-05 TE-127m 9.67E-06 3.43E-05 1.15E-06 2.30E-06 3.92E-05 NO DATA 2.41E-05 TE-127 1.58E-07 5.60E-08 3.40E-08 1.09E-07 6.40E-07 NO DATA 1.22E-05 TE-129m 1.63E-05 6.05E-06 2.58E-06 5.26E-06 6.82E-05 NO DATA , 6.12E-05 TE-129 4.48E-08 1.67E-08 1.09E-08 3.20E-08 1.88E-07 NO DATA 2.45E-07 TE-131m 2.44E-06 1.17E-06 9.76E-07 1.76E-06 1.22E-05 NO DATA 9.39E-05 TE-131 2.79E-08 1.15E-08 8.72E-09 2.15E-08 1.22E-07 NO DATA 2.29E-09 TE-132 3.49E-06 2.21E-06 2.08E-06 2.33E-06 2.12E-05 NO DATA 7.00E-05 I-130 1.03E-06 2.98E-06 1.19E-06 2.43E-04 4.59E-06 NO DATA 2.29E-06 I-131 5.85E-06 8.19E-06 4.40E-06 2.39E-03 1.41E-05 NO DATA 1.62E-06 I-132 2.79E-07 7.30E-07 2.62E-07 2.46E-05 1.15E-06 NO DATA 3.18E-07 I-133 2.01E-06 3.41E-06 1.04E-06 4.76E-04 5.98E-06 NO DATA 2.58E-06 I-134 1.46E-07 3.87E-07 1.39E-07 6.45E-06 6.10E-07 NO DATA 5.10E-09 O CLINTON-I 3-53 Rev.5-2/89
CPS-0DCM t n I
/ TABLE 3.5-8 (continued)
INGESTION DOSE FACTORS FOR TEEN - (DFL g ), (mrem per pCi ingested) NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI I-135 6.10E-07 1.57E-06 5.82E-07 1.01E-04 2.48E-06 'NO DATA 1.74E-06 CS-134 8.37E-05 1.97E-04 9.14E-05 NO DATA 6.26E-05 2.39E-05 2.45E-06 CS-136 8.59E-06 3.38E-05 2.27E-05 NO DATA 1.84E-05 2.90E-06 2.72E-06 CS-137 1.12E-04 1.49E-04 5.19E-05 NO DATA 5.07E-05 1.97E-05 2.12E-06 CS-138 7.76E-08 1.49E-07 7.45E-08 NO DATA 1.10E-07 1.28E-08 6.76E-11
! BA-139 1.39E-07 9.78E-11 4.05E-09 NO DATA 9.22E-11 6.74E-11 1.24E-06 BA-140 2.84E-05 3.48E-08 1.83E-06 NO DATA 1.18E-08 2.34E-08 4.38E-05 BA-141 6.71E-08 5.01E-11 2.24E-09 NO DATA 4.65E-11 3.43E-11 1.43E-13 BA-142 2.99E-08 2.99E-11 1.84E-09 NO DATA 2.53E-11 1.99E-11 9.18E-20 LA-140 3.48E-09 1.71E-09 4.55E-10 NO DATA NO DATA NO DATA 9.82E-05 -
M LA-142 1.79E-10 7.95E-11 1.98E-11 NO DATA NO DATA NO DATA 2.42E-06 CE-141 1.33E-08 8.88E-09 1.02E-09 NO DATA 4.18E-09 NO DATA 2.54E-05 ()) - CE-143 2.35E-09 1.71E-06 1.91E-10 NO DATA 7.67E-10 NO DATA 5.14E-05 CE-144 6.96E-07 2.8CE-07 3.74E-08 NO DATA 1.72E-07 NO DATA 1.75E-04 PR-143 1.31E-08 5.23E-09 6.52E-10 NO DATA 3.04E-09 NO DATA 4.31E-05
~'
PR-144 4.30E-11 1.76E-11 2.18E-12 NO DATA 1.01E-11 NO DATA 4.74E-14 ND-147 9.38E-09 1.02E-08 6.11E-10 NO DATA 5.99E NO DATA 3.68E-05 W-187 1.46E-07 1.19E-07 4.17E-08 NO DATA NO DATA NO DATA 3.22E-05 NP-239 1.76E-09 1.66E-10 9.22E-11 NO DATA 5.21E-10 NO DATA 2.67E-05 I
- 4.06 X 10-06
** Less than 10-24 l
i l c . l l , i 1 O - l CLINTON-1 3-54 Rev.1-11/85
l CPS-0DCM i TABLE 3.5 _9 INGESTION DOSE FACTORS FOR ADULT - (DFLf ) (mrem per pCi ingested) NU2LIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI H-3 NO DATA 1.05E-07 1.05E-07 1.05E-07 1.05E-07 '1.05E-07 1.05E-07 C-14 2.84E-06* 5.68E-07 5.68E-07 5.68E-07 5.68E-07 5.68E-07 5.68E-07 NA-24 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 P-32 1.93E-04 1.20E-05 7.46E-06 NO DATA NO DATA NO DATA 2.17E-05 CR-51 NO DATA NO DATA 2.66E-09 1.59E-09 5.86E-10 3.53E-09 6.69E-07
; MN-54 NO DATA 4.57E-06 8.72E-07 NO DATA 1.36E-06 NO DATA 1.40E-05 MN-56 NO DATA 1.15E-07 2.04E-08 NO DATA 1.46E-07 NO DATA 3.67E-06 FE-55 2.75E-06 1.90E-06 4.43E-07 NO DATA NO DATA 1.06E-06 1.09E-06 FE-59 4.34E-06 1.02E-05 3.91E-06 NO DATA NO DATA 2.85E-06 3.40E-05 l .
CO-58 NO DATA 7.45E-07 1.67E-06 NO DATA NO DATA NO DATA 1.51E-05 -
~
I CO-60 NO DATA 2.14E-06 4.72E-06 NO DATA NO DATA NO DATA 4.02E-05 NI-63 1.30E-04 9.01E-06 4.36E-06 NO DATA NO DATA NO DATA 1.88E-06 1 , j NI-65 5.28E-07 6.86E-08 3.13E-08 NO DATA NO DATA NO DATA 1.74E-06 l
! CU-64 NO DATA 8.33E-08 3.91E-08 NO DATA 2.10E-07 NO DATA 7.10E-06 ZN-65 4.84E-06 1.54E-05 6.96E-06 NO DATA 1.03E-05 NO DATA 9.70E-06 1
l ZN-69 1.03E-08 1.97E-08 1.37E-09 NO DATA 1.28E-08 NO DATA 2.960-09 l BR-83 NO DATA NO DATA 4.02E-08 NO DATA NO DATA NO DATA 5.79E-08 BR-84 NO DATA NO DATA 5.21E-08 NO DATA NO DATA NO DATA 4.09E-13 r BR-85 NO DATA NO DATA 2.14E-09 NO DATA NO DATA NO DATA LT E-24** I RB-86 NO DATA 2.11E-05 9.83E-06 NO DATA NO DATA NO DATA 4.16E-06 RB-88 NO DATA 6.05E-08 3.21E-08 NO DATA NO DATA NO DATA 8.36E-19 l RB-89 NO DATA 4.01E-08 2.82E-08 NO DATA NO DATA NO DATA 2.33E-21 SR-89 3.08E-06 MO DATA 8.84E-06 NO DATA NO DATA NO DATA 4.94E-05 SR-90 7.58E- E: 50 DATA 1.86E-03 NO DATA NO DATA NO DATA 2.19E-04 l SR- 91 5.67E-06 NO DATA 2.29E-07 NO DATA NO DATA NO DATA 2.70E-05 ! SR-92 2.15E-06 NO DATA 9.30E-08 NO DATA NO DATA NO DATA 4.26E-05 l Y-90 9.62E-09 NO DATA 2.58E-10 NO DATA NO DATA NO DATA 1.02E-04 j
\ ,)
i CLINTON-I 3-55 Rev.1-11/85 l 1 L______
t
' CPS-ODCM l
l l
- TABLE 3.5-9 (continued)
( INGESTION DOSE FACTORS FOR ADULT - (DFL t ), j (mrem per pCi ingested) l NUCLIDE BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI , I Y-91m 9.09E-11 NO DATA 3.52E-12 NO DATA NO DATA NO DATA 2.67E-10 ) Y-91 1.41E-07 NO DATA 3.77E-09 NO DATA NO DATA NO DATA 7.76E-05 ! Y-92 8.45E-10 NO DATA 2.47E-11 NO DATA NO DATA NO DATA 1.48E-05 1 Y-93 2.68E-09 NO DATA 7.40E-11 NO DATA NO DATA NO DATA 8.50E-05 ZR-95 3.04E-08 9.75E-09 6.60E-09 NO DATA 1.53E-08 NO DATA 3.09E-05 ZR-97 1.68E-09 3.39E-10 1.55E-10 NO DATA 5.12E-10 NO DATA 1.05E-04 NB-95 6.22E-09 3.46E-09 1.86E-09 NO DATA 3.42E-09 NO DATA 2.10E-05 M0-99 NO DATA 4.31E-06 8.20E-07 NO DATA 9.76E-06 NO DATA 9.99E-06 TC-99m 2.47E-10 6.98E-10 8.89E-09 NO DATA 1.06E-08 3.42E-10 4.13E-07 ! TC-101 2.54E-10 3.66E-10 3.59E-09 NO DATA 6.59E-09 1.87E-10 1.10E-21 RU-103 1.85E-07 NO DATA 7.97E-08 NO DATA 7.06E-07 NO DATA 2.16E-05 RU-105 1.54E-08 NO DATA 6.08E-09 NO DATA 1.99E-07 NO DATA 9.42E-06 D U RU-106 2.75E-06 NO DATA 3.48E-07 NO DATA 5.31E-06 NO DATA 1.78E-04 AG-110m 1.60E-07 1.48E-07 8.79E-08 NO DATA 2.91E-07 NO DATA 6.04E-05 TE-125m 2.68E-06 9.71E-07 3.59E-07 8.06E-07 1.09E-05 NO DATA 1.07E-05 TE-127m 6,77E-06 2.42E-06 8.25E-07 1.73E-06 2.75E-05 NO DATA 2.27E-05 TE-127 1.10E-07 3.95E-08 2.38E-08 8.15E-08 4.48E-07 NO DATA 8.68E-06 TE-129m 1.15E-05 4.29E-06 1.82E-06 3.95E-06 4.80E-05 NO DATA 5.79E-05 TE-129 3.14E-08 1.18E-08 7.65E-09 2.41E-08 1.32E-07 NO DATA 2.37E-08 TE-131m 1.73E-06 8.46E-07 7.05E-07 1.34E-06 8.57E-06 NO DATA 8.40E-05 TE-131 1.97E-08 8.23E-09 6.22E-09 1.62E-08 8.63E-t6 NO DATA 2.79E-09 TE-132 2.52E-06 1.63E-06 1.53E-06 1.80E-06 1.57E-05 NO DATA 7.71E-05 I-130 7.56E-07 2.23E-06 8.80E-07 1.89E-04 3.48E-06 NO DATA 1.92E-06 I-131 4.16E-06 5.95E-06 3.41E-06 1.95E-03 1.02E-05 NO DATA 1.57E-06 I-132 2.03E-07 5.43E-07 1.90E-07 1.90E-05 8.65E-07 NO DATA 1.02E-07 I-133 1.42E-06 2.47E-06 7.53E-07 3.63E-04 4.31E-06 NO DATA 2.22E-06 I-134 1.06E-07 2.88E-07 1.03E-07 4.99E-06 4.58E-07 NO DATA 2.51E-10 t O CLINTON-I 3-56 Rev.5-2/89
l CPS-0DCM O k- TABLE 3.5-9 (continued) INGESTION DOSE FACTORS FOR ADULT - (DFLg ) (mrem per pCi ingested) BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI
.NUCLIDE I-135 4.43E-07 1.16E-06 4.28E-07 7.65E-05 1.86E-06 'NO DATA 1.31E-06 CS-134 6.22E-05 1.48E-04 1.21E-04 NO DATA 4.79E-05 1.59E-05 2.59E-06 ! CS-136 6.51E-06 2.57E-05 1.85E-05 NO DATA 1.43E-05 1.96E-06 2.92E-06 CS-137 7.97E-05 1.09E-04 7.14E-05 NO DATA 3.70E-05 1.23E-05 2.11E-06
( CS-138 5.52E-08 1.09E-07 5.40E-08 NO DATA 8.01E-08 7.91E-09 4.65E-13 BA-139 9.70E-08 6.91E-11 2.84E-09 NO DATA 6.46E-11 3.92E-11 1.72E-07 l
! 8.67E-09 1.46E-08 4.18E-05 BA-140 2.03E-05 2.55E-08 1.33E-06 NO DATA BA-141 4.71E-08 3.56E-11 1.59E-09 NO DATA 3.31E-11 2.02E-11 2.22E-17 BA-142 2.13E-08 2.19E-11 1.34E-09 NO DATA 1.85E-11 1.24E-11 3.00E-26 LA-140 2.50E-09 1.26E-09 3.33E-10 NO DATA NO DATA NO DATA 9.25E-05 ...,
NO DATA 4.25E-07 "" [ LA-142 CE-141 1.28E-10 9.36E-09 5.82E-11 6.33E-09 1.45E-11 7.18E-10 NO DATA NO DATA NO DATA 2.94E-09 NO DATA 2.42E-05 CE-143 1.65E-09 1.22E-06 1.35E-10 NO DATA 5.37E-10 NO DATA 4.56E-05 CE-144 4.88E-07 2.04E-07 2.62E-08 NO DATA 1.21E-07 NO DATA 1.65E-04 PR-143 9.20E-09 3.69E-09 4.56E-10 NO DATA 2.13E-09 NO DATA 4.03E-05
'l PR-144 3.01E-11 1.25E-11 1.53E-12 NO DATA 7.05E-12 NO DATA 4.33f'18 ND-147 6.29E-09 7.27E-09 4.35E-10 NO DATA 4.25E-09 NO DATA 3.49E-05 W-187 1.03E-07 8.61E-08 3.01E-08 NO DATA NO DATA NO DATA 2.82E-05 NP-239 1.19E-09 1.17E-10 6.45E-11 NO DATA 3.65E-10 NO DATA 2.40E-05 .
- 2.84 X 10 -06 l
** Less than 10-24 l
1 b O CLINTON-I 3-57 Rev.1-11/85 t
i CPS-0DCM 3 l TABLE 3.5-10 ' (. C INPUT PARAMETERS FOR CALCULATING Ray 1 Parameter Value Table
- I
=
Qp (kg/ day) 50 tor cow E-3 1 6 for goat . E-3 l l U aP (liters /yr) - Infant 330 E-5 I Child 330 E-5. i Teen 400 E-5 i - Adult 310 E-5 Y 0.7 E-15 p (kg/m2) Y, (kg/m2 ) 2.0 E-15 F* (days / liter) Each stable element for cow E-1 Each stable element for goat E-2 r (dimensionless) 1.0 for radiciodine E-15 0.2 for particulate E-15 e 1.73 x 105 (2 days) E-15 f (seconds) h- , t 7.78 x 106 (90 days) E-15 h (seconds) f g. (dimensionless) 1.0 for cow NUREG 1.0 for goat -0133 Section 5.3.1.3 i
; 1.0 for cow NUREU' fP (dimensionless) 1.0 for goat -0133 I Section I 5.3.1.3 l
l 1 1
*of Regulatory Guice 1.109 unless otherwise stated CLINTON-I 3-58 Rev.1-11/85
CPS-0DCM t x / TABLE 3.5-11 mI M INPUT PARAMETERS FOR CALCULATING Raj l Parameter Value Table
- U ap - Infant 0 E-5 (kg/yr) - Child 41 E-5
- Teen 65 E-5 - Adult 110 E-5 ; Ff (days /kg) Each stable E-1 1
element t (seconds) 1.73E+06 E-15 8 (20 days) t 7.78E+06 E-15 l h (see nds) (90 days) l Y 0.7 E-15 l p (kg/m2) Y, (kg/m2) 2.0 E-15 (
)s) r (dimensionless) 1.0 for radioiodine 0.2 for particulate E-15 E-15 \,,)
50 E-3 Qf (kg/ day) l l l l l 1 l l l *of Regulatory Guide 1.109 l ! l '\ ,! l CLINTON-I 3-59 Rev.1-11/85 l
CPS-0DCM TABLE 3.5-12 V INPUT PARAMETERS FOR CALCULATING R Parameter Value Table
- E-5 i
I U" (kg/yr) -- Infant Child 0 26 E-5
- Teen 42 E-5 l - Adult 64 E-5 l
S 0 E.- 5 U (kg/yr) - Infant i - Child 520 E-5
- Teen 6?O E-5 - Adult 520 E-5 1.0 E-15 fg (dimensionless) fg 0.76 E-15 , (dimensionless) t g (seconds 8.6 x 100 (1 day) E-15 t
5.18 x 106 (60 days) E-15
; h (seconds) _
Yy (kg/m2) 2.0 E-15 i I i i l i
- or Regulatory Guide 1.109 O
CLINTON-I 3-60 Rev.1-11/85
CPS-0DCM TABLE 3.5-13 o INHALATION PATHWAY FACTORS - R (INFANT) l l (mrem /yr perpCi/m3) l l ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE l H-3 NO DATA 6.47E+02* 6.47E+02* 6.47E+02* 6.47E+02* 6.47E+02* 6.47E+02* C-14 2.65E+04 5.31E+03 5.32E+03 5.31E+03 5.31E+03 5.31E+03 5.31E+03 NA-24 1.06E+04 1.06EM4 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 I P-32 2.03E+06 1.12E+05 7.74E+04 NO DATA NO DATA NO DATA 1.61E+04 CR-51 NO DATA NO DATA 8.95E+01 5.75E+01 1.32E+01 1.28E+04 3.57E+02 MN-54 NO DATA 2.53E+04 4.98E+03 NO DATA 4.98E+03 1.00E%6 7.06E+03 MN-56 NO DATA 1.54E% 0 2.21E-01 NO DATA 1.10E+00 1.25E+04 7.17E+04 FE-?5 1.97E+04 1.17E+04 3.33E+03 NO DATA NO DATA 8.69E+04 1.09E@3 FE-59 1.36E+04 2.35E+04 9.48E+03 NO DATA NO DATA 1.02E+06 2.48E+04 CO-58 NO DATA 1.22E+03 1.82E+03 NO DATA NO DATA 7.77E+05 1.11E+04 ; CO-60 NO DATA 8.02E+03 1.18E+04 NO DATA NO DATA 4.51E+06 3.19E+04 i V NI-63 3.39E+05 2.04E404 1.16E+0<, NO DATA NO DATA 2.09E+05 2.42E+03 NI-65 2.39EMO 2.84E-01 1.23E-01 NO DATA NO DATA 8.12E+03 5.01E+04 CU-64 NO DATA 1.88E+00 7.74E-01 NO DATA 3.98E+00 9.30E+03 1.50E+04 ZN-65 1 93E+04 6.26E+04 3.11EM4 F0 DATA 3.25E+04 6.47E+05 5.14E+04 Zri-69 5.39E-02 9.67E-02 7.18E-03 NO DATA 4.02E-02 1.47E+03 1.32E+04 BR-83 NO DATA NO DATA 3.81E+02 NO DATA NO DATA NO DATA ' LT1.4E-15** BR-84 NO DATA NO DATA 4.00E+02 NO DATA NO DATA NO DATA LT1.4E-15 i BR-85 NO DATA NO DATA 2.04E+01 NO DATA NO DATA NO DATA LT1.4E-15 RB-86 NO DATA 1.90E+05 8.82E+04 NO DATA NO DATA NO DATA 3.04E+03 RB-88 NO DATA 5.57E+02 2.87E+02 NO DATA NO DATA NO DATA 3.39E+02 l RB-89 NO DATA 3.21E+02 2.06E+02 NO DATA NO DATA NO DATA 6.82E+01 l SR-89 3.98E+05 1.14E+04 6.406! % NO DATA NO DATA NO DATA 2.03E+06 1 SR-90 4.09E+07 NO DATA 2.59E+06 NO DATA NO DATA 1.12E+07 1.31EW5 l l l l l CLINTON-I 3-61 Rev.5-2/89 L _ - __-___-__ _ _ _ _ _ _ _ _
CPS-0DCM I
\
1 i TABLE 3.5-13 (continued) ' b INHALATION PATHWAY FACTORS - R (INFANT) (mrem /yr per pCi/m3) O'IGAN : BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI f ISOTOPE { l SR-91 9.56E+01 NO DATA 3.46E+00 NO DATA NO DATA 5.26E+04 7.34E+04 SR-92 1.05E+01 NO DATA 3.91E-01 NO DATA NO DATA 2.38E+04 1.40E+05 Y-90 3.29E+03 NO DATA 8.82E+01 NO DATA NO DATA 2.69E+05 1.04E+05 Y-91m 4.07E-01 NO DATA 1.39E-02 NO DATA NO DATA 2.79E+03 2.35E+03 Y-91 5.88E+05 NO DATA 1.57E+04 NO DATA NO DATA 2.45E+06 7.03E+04 Y-92 1.64E+01 NO DATA 4.61E-01 NO DATA NO DATA 2.45E+04 1.27EM5 Y-93 1.50E+02 NO DATA 4.07E+00 NO DATA NO DATA 7.64E+04 1.67E+05 ZR-95 1.15E+05 2.79E+04 2.03E+04 NO DATA 3.11E+04 1.75EM 6 2.17E+04 ZR-97 1.5G::+02 2.56E+01 1.17E+01 NO DATA 2.59E+01 1.10E+05 1.40E+05 NB-95 1.57E+04 6.43E+03 3.78E+03 NO DATA 4.72E+03 4.79E@5 1.27E+04 H0-99 NO DATA 1.65E+02 3.23E+01 NO DATA 2.65E+02 1.35E+05 4.87E+04 TC-99m 1.40E-03 2.88E-03 3.72E-02 NO DATA 3.11E-02 8.11E+02 2.03E+03 TC-101 6.51E-05 8.23E-05 8.12E-04 NO DATA 9.79E-04 5.84E+02 8.44E+07 RU-103 2.02E+03 NO DATA 6.79E+02 NO DATA 4.24E+03 5.52E+05 1.61E+04 RU-105 1.22E+00 NO DATA 4.10E-01 NO DATA 8.99E-01 1.57E+04 4.84E+04 RU-106 8.68E+04 NO DATA 1.09EM4 NO DATA 1.07E+05 1.16E+07 1.64E+05 AG-110m 9.98E+03 7.22E+03 5.00E+03 NO DATA 1.09E+04 3.67E+06 3.30E+04 TE-123m 4.76E+03 1.99E+03 6.58EM2 1.62E+03 NO DATA 4.47E+05' 1.29E+04 TE-127m 1.67E+04 6.90EM3 2.07E+03 4.87E+03 3.75E+04 1.31E+06 2.73E+04 TE-127 2.23E+00 9.53E-01 4.89E-01 1.85E+00 4.86E+00 1.03E+04 2.44E+04 TE-129m 1.41EM4 6.09E+03 2.23E+03 5.47E@3 3.18EM4 1.68E+06 6.90E+04 TE-129 7.88E-02 3.47EM2 1.88E-02 6.75E-02 1.75E-01 3.00E+03 2.63E+04 TE-131m 1.07E+02 5.50E+01 3.63E+01 8.93E+01 2.65E+02 1.99E+05 1.19 EMS l TE-131 1.74E-02 8.22E-03 5.00E-03 1.58E-02 3.99E-02 2.06E+03 8.22E+03 l TE-132 3.72E+02 2.37E+02 1.76E+02 2.79EM2 1.03E+03 3.40E+05 4.41E+04 I-130 6.36E+03 1.39E+04 5.57E+03 1.60E+06 1.53E+04 NO DATA 1.99E+03 1-131 3.79E+04 4.44E+04 1.96E+04 1.48E+07 5.18E+04 NO DATA 1.06E+03 CLINTON-I 3-62 Rev.5-2/89
CPS-ODCM TABLE 3.5-13 (continued) INHALATION PATHWAY FACTORS - R (INFANT) (mrem /yr per pCi/m3) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE I-132 1.69EM3 3.54E+03 1.26E+03 1.69E+05 3.95E+03 NO DATA 1.90E+03 I-133 1.32E+04 1.92E+04 5.60E+03 3.56E+06 2.24E+04 NO DATA 2.16E+03 I-134 9.21E+02 1.88E+03 6.65E+02 4.45E+04 2.09E+03 NO DATA 1.29E+03 I-135 3.86E+03 7.60E+03 2.77E+03 6.96E+05 8.47EM3 NO DATA 1.83E+03 CS-134 3.96E+05 7.03E+05 7.45E+04 NO DATA 1.90E+05 7.97E+04 1.33E+03 CS-136 4.83E+04 1.35E+05 5.29E+04 NO DATA 5.64E+04 1.18E+04 1.43E+03 CS-137 5.49E+05 6.12E+05 4.55E+04 NO DATA 1.72E+05 7.13E+04 1.33E+03 CS-138 5.05E+02 7.81E+02 3.98E+02 NO DATA 4.10E+02 6.54E+01 8.76E+02 BA-139 1.48E+00 9.84E-04 4.30E-02 NO DATA 5.92E-04 5.95E+03 5.10E+04 BA-140 5.60E+04 5.60E+01 2.90E+03 NO DATA 1.34E+01 1.60E+06 3.84E+04 BA-141 1.57E-01 1.08E-04 4.97E-03 NO DATA 6.50E-05 2.97E+03 4.75E+03 BA-142 3.98E-02 3.30E-05 1.96E-03 NO DATA 1.90E-05 1.55E+03 6.93E+02 LA-140 5.05E+02 2.00E+02 5.15E+01 NO DATA NO DATA 1.68E+05 8.48EM4 LA-142 1.03E+00 3.77E-01 9.04E-02 NO DATA NO DATA 8.22E+03 5.95E+04 CE-141 2.77E+04 1.67E+04 1.99E+03 NO DATA 5.25E+03 5.17E+05 2.16E+04 CE-143 2.93E+02 1.93E+02 2.21E+01 NO DATA 5.64E+01 1.16E+05 4.97E+04 CE-144 3.19E+06 1.21E+06 1.76E+05 NO DATA 5.38E+05 9.84E+06 1.48E+05 PR-143 1.40E+04 5.24E+03 6.99E+02 NO DATA 1.97E+03 4.33E+05' 3.72E+0i PR-144 4.79E-02 1.85E-02 2.41E-03 NO DATA 6.72E-03 1.61E+03 4.28E+03 ND-147 7.94E+03 8.13E+03 5.00E+02 NO DATA 3.15E+03 3.22E+05 3.12E+04 W-187 1.30E+01 9.02E+00 3.12E+00 NO DATA NO DATA 3.96E+04 3.56E+04 NP-239 3.71E+02 3.32E+01 1.88E+01 NO DATA 6.62E+01 5.95E+04 2.49E+04 2
- 6.47 x 10
** Less than 1.40 x 10-15 O
I CLINTON-I 3-63 Rev.5-2/89 l c__________-__________. _. ._
- CPS-0DCM l
l l l TABLE 3.5-14 l () I INHALATION PATHWAY FACTORS - Raij ( HM) (mrem /yr per pC1/m3) l l ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI I ISOTOPE i H-3 NO DATA 1.12EM3* 1.12E+03 1.12E+03 1.12E+03 1.12E+03 1.12E+03 j C-14 3.58E+04 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 1 NA-24 1.61E+04 1.61E%4 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 l 2.60EM6 4.21E+04 P-32 1.14E+05 9.87E+04 NO DATA NO DATA NO DATA CR -51 NO DATA NO DATA 1.54E+02 8.54E+01 2.43E+01 1.70E+04 1.08E+03 MN-54 NO DATA 4.29E+04 9.51EM3 NO DATA 1.00E+04 1.58E+06 2.29E+04 { MN-56 NO DATA 1.66E+00 3.12E-01 NO DATA 1.67E+00 1.31E+04 1.23E+05 FE-55 4.74E+04 2.52E+04 7.77E+03 NO DATA NO DATA 1.11E+05 2.87E+03 FE-59 2.07E+04 3.34E+04 1.67E+04 NO DATA NO DATA 1.27E+06 7.07E%4 C0-58 NO DATA 1.77E+03 3.16EM3 NO DATA NO DATA 1.11EM6 3.44E+04 CO-60 NO DATA 1.31E+04 2.26E+04 NO DATA NO DATA 7.07E+06 9.62E+04 O NI-63 8.21E+05 4.63E+04 2.80E+04 NO DATA NO DATA 2.75E+05 6.33E+03 k) I NI-65 2.99E%0 2.96E-01 1.64E-01 NO DATA NO DATA 8.18E+03 8.40E+04 CU-64 NO DATA 1.99E+00 1.07E+00 NO DATA 6.03E+00 9.58E+03 3.67E+04 ZN-65 4.26E+04 1.13E%5 7.03E+04 NO DATA 7.14E+04 9.95E+05 1.63E+04 ZN-69 6.70E-02 9.66E-02 8.92E-03 NO DATA 5.85E-02 1.42E+03 1.02E+04 BR-83 NO DATA NO DATA 4.74E+02 NO DATA NO DATA NO DATA LT3.70E-15** BR-84 NO DATA NO DATA 5.48E+02 NO DATA NO DATA NO DATA IT3.70E-15 BR-85 NO DATA NO DATA 2.53EM I NO DATA NO DATA NO DATA LT3.70E-15 i RB-86 NO DATA 1.98E+05 1.14E+05 NO DATA NO DATA NO DATA 7.99E+03 RB-88 NO DATA 5.62E+02 3.66E+02 NO DATA NO DATA NO DATA 1.72E+01 RB-89 NO DATA 3.45E+02 2.89E402 NO DATA NO DATA NO DATA 1.89E+00 SR-89 5.99E+05 NO DATA 1.72E+04 NO DATA NO DATA 2.16E+06 1.67E+05 SR-90 1.01E+08 NO DATA 6.44E+06 NO DATA NO DATA 1.48E+07 3.43E+05 SR-91 1.21E+02 NO DATA 4.59E+00 NO DATA NO DATA 5.33E+04 1.74E+05 SR-92 1.31E+01 NO DATA 5.25E-01 NO DATA NO DATA 2.40E+04 2.42E+05 Y-90 4.11E+03 NO DATA 1.11EM 2 NO DATA NO DATA 2.62E+05 2.66E+05 CLINTON-I 3-64 Rev.5-2/89 _ _ _ _ _ _ _ _ _ _ _ __ ______________________ a
~
CPS-0DCM TABLE 3.5-14 (continued) O anit^r1onr^ raw ^vr^croas-ak(c"'o) (mrem /yr per pCi/m3) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE Y-91m 5.07E-01 NO DATA 1.84E-02 NO DATA NO DATA 2.81E+03 1.72E+03 Y-91 9.14E+05 NO DATA 2.44E+04 NO DATA NO DATA 2.63E+06 1. fi4E+05 Y-92 2.04E+01 NO DATA 5.81E-01 NO DATA NO DATA 2.39E+04 2.39E+05 Y-93 1.86E+02 NO DATA 5.11E+00 NO DATA NO DATA 7.44E+04 3.89E+05 ZR-95 1.90E+05 4.18E+04 3.7CE+04 NO DATA 5.96E+04 2.23E+06 6.11E+04 ZR-97 1.88E+02 2.72E+01 1.60EM1 NO DATA 3.89E+01 1.13E+05 3.51E+05 NB-95 2.35E+04 9.18EM3 6.55E+03 NO DATA 8.62E+03 6.14E+05 3.70E+04 M0-99 NO DATA 1.72E+02 4.26E+01 NO DATA 3.92E+02 1.35E+05 1.27E+05 TC-99m 1.78E-03 3.48E-03 5.77E-02 NO DATA 5.07E-02 9.51E+02 4.81E+03 TC-101 8.10E-05 8.51E-05 1.08E-03 NO DATA 1.45E-03 5.84E+02 1.63E+01 RU-103 2.79E+03 NO DATA 1.07E+03 NO DATA 7.03E+03 6.62E+05 4.48E+04 RU-105 1.53E+00 NO DATA 5.55E-01 NO DATA 1.34E+00 1.59E+04 9.95E+04 RU-106 1.36E+05 NO DATA 1.69EM4 NO DATA 1.84EM5 1.43E+07 4.29E+05 AG-110m 1.69E+04 1.14E+04 9.14E+03 NO DATA 2.12E+04 5.48E+06 1.00E+V TE-125m 6.73E+03 2.33EM3 9.14E+02 1.92E+03 NO DATA 4.77E+05 3.38E+04 TE-127m 2.49E+04 8.55E+03 3.02E+03 6.07E+03 6.36E+04 1.48E+06 7.14E+04 TE-127 2.77E+00 9.51E-01 6.11E-01 1.96E+00 7.07E+00 1.00E+04 5.62E+04 TE-129m 1.92E+04 5.85E+03 3.04E+03 6.33E+03 5.03E+04 1.76EM6' 1.82E+05 TE-129 9.77E-02 3.50E-02 2.38E-02 7.14E-02 2.57E-01 2.93E+03 2.55E+04 TE-131m 1.34E+02 5.92E+01 5.07E+01 9.77E+01 4.00E+02 2.06E+05 3.08E+05 TE-131 2.17E-02 8.44E-03 6.59E-03 1.70E-02 5.88E-02 2.05E+03 1.33E+03 l TE-132 4.81E+02 2.72E%2 2.63E+02 3.17EM2 1.77E%3 3.77E+05 1.38E+05 l I-130 8.18E+03 1.64E+04 8.44E+03 1.85E+06 2.45E+04 NO DATA 5.11E+03 I-131 4.81E+04 4.81E+04 2.73E+04 1.62E+07 7.88E+04 NO DATA 2.84E+03 I-132 2.12E+03 4.07E+03 1.88E+03 1.94EM5 6.25E+03 NO DATA 3.20E+03 I-133 1.66E+04 2.03E+04 7.70E+03 3.85E+06 3.38E+04 NO DATA 5.48E+03 1-134 1.17E+03 2.16E+03 9.95E+02 5.07E%4 3.30E+03 NO DATA 9.54E+02 j CLINTON-I 3-65 Rev.5-2/89
CPS-0DCM TABLE 3.5-14 (continued)
/ '
INHALATION. PATHWAY FACTORS - R,f)(CHILD) (mrem /yr per yCi/m3) l ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE I-135 4.92E+03 8.73EM 3 4.14EM3 7.92E+05 1.34E+04 UO DATA 4.44E+03 ' CS-134 6.51E+05 1.01E+06 2.25E+05 NO DATA 3.30E+05 1.21E+05 3.85E+03 CS-136 6.51E+04 1.71E+05 1.16E+05 NO DATA 9.55E+04 1.45E F04 4.18E+03 CS-137 9.07E+05 8.25E+05 1.28E+05 NO DATA 2.82E+05 1.04E+05 3.62E+03 j CS-138 6.33E+02 8.40E+02 5.55E+02 NO DATA 6.22E+02 6.81E+01 2.70E+02 i BA-139 1.84E+00 9.84E-04 5.37E-02 NO DATA 8.62E-04 5.77E+03 5.77E+04 ! I BA-140 7.40E+04 6.48E+01 4.33E+03 NO DATA 2.11E+01 1.74E+06 1.02E+05 BA-141 1.96E-01 1.09E-04 6.36E-03 NO DATA 9.47E-05 2.92E+03 2.75E+02 BA-142 5.00E-02 3.60E-05 2.79E-03 NO DATA 2.91E-05 1.64EM3' 2.74E+00 LA-140 6.44E+02 2.25E+02 7.55E+01 NO DATA NO DATA 1.83 EMS 2.26E+05 LA-142 1.30E+00 4.11E-01 1.29E-01 NO DATA NO DATA 8.70E+03 7.59E+04 l CE-141 3.92E+04 1.95E+04 2.90E+03 NO DATA 8.55E+03 5.44E+05 5.66E+04 CE-143 3.66E+02 1.99EM2 2.87E+01 NO DATA 8.36EMI 1.15E+05 1.27E+05 I CE-144 6.77E+06 2.12E+06 3.61E+05 NO DATA 1.17E+06 1.20E+07 3.89E+05 PR-143 1.85E+04 5.55E+03 9.14E+02 NO DATA 3.00E+03 4.33Et05 9.73E+04 PR-144 5.96E-02 1.85E-02 3.00E-03 NO DATA 9.77E-03 1.57E+03 1.97E+02 ND-147 1.08E+04 8.73E+03 6.81E+02 NO DATA 4.81E+03 3.28E+05 8.21E+04 W-187 1.63E+01 9.66E+00 4.33E+00 NO DATA NO DATA 4.11E+04' 9.10E+04 NP-239 4.66E+02 3.34EMI 2.35E+01 NO DATA 9.73E+01 5.81E+04 6.40E+04 1
- 1 12 x 103
** Less than 3.70 x 10-15 O
CLINTON-I 3-66 Rev.5-2/89
CPS-0DC2d l l TABLE 3.5-15 0 tua^t^rtonr^ raw ^vr^croas-a6(188") (mrem /yr per pCi/m8) j l ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE H-3 NO DATA 1.27E+03* 1.27E+03 1.27E+03 1.27E+03 1.27E+03 1.27E+03 ; C-14 2.60E+04 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 NA-24 1.38E+04 1.38E+04 1.38E+04 1.38E404 1.38E+04 1.38E+04 1.38E+04 P-32 1.89E+06 1.10E+05 7.16E+04 NO DATA NO DATA NO DATA 9.28E+04 CR-51 NO DATA NO DATA 1.35E+02 7.50E+01 3.07E+01 2.10E+04 3.00E+03 MN-54 NO DATA 5.11E+04 8.40E+03 NO DATA 1.27E+04 1.98E406 6.68E+04 MN-56 NO DATA 1.70E+00 2.52E-01 NO DATA 1.79E+00 1.52E+04 5.74E+04 FE-55 3.34E+04 2.38E+04 5.54E+03 NO DATA NO DATA 1.24E+05 6.39E+03 . FE-59 1.59E+04 3.70E+04 1.43E+04 NO DATA NO DATA 1.53E+06 1.78E+05 Co-58 NO DATA 2.07E+03 2.78E+03 NO DATA NO DATA 1.34E+06 9.52E+04 CO-60 NO DATA 1.51E+04 1.98E+04 NO DATA NO DATA 8.72E+06 2.53E+05 NI-63 5.80E+05 4.34E+04 1.98E+04 NO DATA NO DATA 3.07E+05 1.42E+04 ( NI-65 2.18E+00 2.93E-01 1.27E-01 NO DATA NO DATA 9.36E+03 3.67E+04 CU-64 NO DATA 2.03E+00 8.48E-01 NO DATA 6.41E+00 1.11E+04 6.14E+04 ZN-65 3.86E+04 1.34E+05 6.24E+04 NO DATA 8.64E+04 1.24E+06 4.66E+04 ZN-69 4.83E-02 9.20E-02 6.46E-03 NO DATA 6.02E-02 1.58E+03 2.85E+02 BR-83 NO DATA NO DATA 3.44E+02 NO DATA NO DATA NO DATA LT8E-15** BR-84 NO DATA NO DATA 4.33E+02 NO DATA NO DATA NO DATA ' LT8E-15 l BR-85 NO DATA NO DATA 1.83E+01 NO DATA NO DATA NO DATA LT8E-15 RB-86 NO DATA 1.90E+05 8.40E+04 NO DATA NO DATA NO DATA 1.77E+04 RB-88 NO DATA 5.46E+02 2.72E+02 NO DATA NO DATA NO DATA 2.92E-05 RB-89 NO DATA 3.52E+02 2.33E+02 NO DATA NO DATA NO DATA 3.38E-07 SR-89 4.34E+05 NO DATA 1.25E+04 NO DATA NO DATA 2.42E+06 3.71E+05 SR-90 1.08E+08 NO DATA 6.68E+06 NO DATA NO DATA 1.65E+07 7.65E+05 SR-91 8.80E+01 NO DATA 3.51E+00 NO DATA NO DATA 6.07E+04 2.59E+05 SR-92 9.52E+00 NO DATA 4.06E-01 NO DATA NO DATA 2.74E+04 1.19E+05 i Y-90 2.98E+03 NO DATA 8.00E+01 NO DATA NO DATA 2.93E+05 5.59E+05 (O/ i CLINTON-I 3-67 Rev.5-2/89 l l
CPS-0DC24 l TABLE 3.5-15 (continued) INHALATION PATHWAY FACTORS - R (TEEN) l (mrem /yr per p Ci/m3 ) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI , ISOTOPE ! Y-91m 3.70E-01 NO DATA 1.42E-02 NO DATA NO DATA 3.20E+03 3.02E+01 l Y-91 6.61E+05 NO DATA 1.77E+04 NO DATA NO DATA 2.94E+06 4.09E+05 Y-92 1.47E+01 NO DATA 4.29E-01 NO DATA NO DATA 2.68E+04 1.65E+05 Y-93 1.35E402 NO DATA 3.722+00 NO DATA NO DATA 8.32E+04 5.79E+05 ZR-95 1.46E+05 4.58E+04 3.1 $2&04 NO DATA 6.74E+04 2.69E+06 1.49E+05 ZR-97 1.38E+02 2.72F+01 1..'6f 431 NO DATA 4.12E+01 1.30E+05 6.30E+05 i NB-95 1.86E+04 1.03E+04 5.66E+03 NO DATA 1.00E+04 7.51E+05 9.68E+04 M0-99 NO DATA 1.69E+02 3.22E+01 NO DATA 4.11E+02 1.54E+05 2.69E+05 TC-99m 1.38E-03 3.86E-03 4.99E-02 NO DATA 5.76E-02 1.15E+03 6.13E+03 TC-101 5.92E-05 8.40E-05 8.24E-04 NO DATA 1.52E-03 6.67E+02 8.72E-07 RU-103 2.10E+03 NO DATA 8.96E+02 NO DATA 7.43E+03 7.83E+05 1.09E+05 RU-105 1.12E+00 NO DATA 4.34E-01 NO DATA 1.41E+00 1.82E+04 9.04E+04 RU-106 9.84E+04 NO DATA 1.24E+04 NO DATA 1.90E+05 1.61E+07 9.60E+05 AG-110m 1.38E+04 1.31E+04 7.99E+03 NO DATA 2.50E+04 6.75E+06 2.73E+05 TE-125m 4.88E+03 2.24E+03 6.67E+02 1.40E+03 NO DATA 5.36E+05 7.50E+04 TE-127m 1.80E+04 8.16E+03 2.18E+03 4.38E+03 6.54E+04 1.66E+06 1.59E+05 l TE-127 2.01E+00 9.12E-01 4.42E-01 1.42E+00 7.28E+00 1.12E+04 8.08E+04 TE-129m 1.39E+04 6.58E+03 2.25E+03 4.58E+03 5.19E+04 1.98E+06' 4.05E+05 TE-129 7.10E-02 3.38E-02 1.76E-02 5.18E-02 2.66E-01 3.30E+03 1.62E+03 TE-131m 9.84E+01 6.01E+01 4.02E+01 7.25E+01 4.39E+02 2.38E+05 6.21E+05 TE-131 1.58E-02 8.32E-03 5.04E-03 1.24E-02 6.18E-02 2.34E+03 1.51E+01 TE-132 3.60E+02 2.90E+02 2.19E+02 2.46E+02 1.95E+03 4.49E+05 4.63E+05 I-130 6.24E+03 1.78E+04 7.17E+03 1.49E+06 2.75E+04 NO DATA 9.12E+03 I-131 3.54E+04 4.91E+04 2.64E+04 1.46E+07 8.40E+04 NO DATA 6.49E+03 l I-132 1.59E+03 4.38E+03 1.58E+03 1.51E+05 6.92E+03 NO DATA 1.27E+03 I-133 1.22E+04 2.05E+04 6.22E+03 2.92E+06 3.59E+04 NO DATA 1.03E+04 l
,_ I-134 8.88E+02 2.32E+03 8.40E+02 3.95E+04 3.66E+03 NO DATA 2.04E+01 CLINTON-I 3-68 Rev.5-2/89 1
h CPS-0DCM TABLE 3.5-15 (continued) ( INHALATION PATHWAY FACTORS - R (TEEN) (mrem /yr per pCi/m3) 1 1 ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE l I-135 3.70E+03 9.44E+03 3.49E+03 6.21E+05 1.49E+04 NO DATA 6.95E+03 l CS-134 5.02E+05 1.12E+06 5.49E+05 NO DATA 3.75E+05 1.46E+05 9.76E+03 CS-136 5.15E+04 1.94E+05 1.37E+05 NO DATA 1.10E+05 1.78E+04 1.09E+04 CS-137 6.70E+05 8.48EM5 3.11E+05 NO DATA 3.04 EMS 1.21E+05 8.48E+03 CS-138 4.66E+02 8.56E+02 4.46E+02 NO DATA 6.62E+02 7.87E+01 2.70E-01 BA-139 1.34E+00 9.44E-04 3.90E-02 NO DATA 8.88E-04 6.46E+03 6.45E+03 BA-140 5.47E+04 6.70E+01 3.52E+03 NO DATA 2.28E401 2.03E+06 2.29E+05 BA-141 1.42E-01 1.06E-04 4.74E-03 NO DATA 9.84E-05 3.29E+03 7. 46E -04 , BA-142 3.70E-02 3.70E-05 2.27E-03 NO DATA 3.14E-05 1.91E+03 4.79E-10 LA-140 4.79E+02 2.36E+02 6.26E+01 NO DATA NO DATA 2.14E+05 4.87E405 i LA-142 9.60E-01 4.25E-01 1.06E-01 NO DATA NO DATA 1.02E+04 1.20E+04 CE-141 2.84E+04 1.90E+04 2.17EM3 NO DATA 8.88EM3 6.14E+05 1.26E+05 CE-143 2.66E+02 1.94EM2 2.16E+01 NO DATA 8.64E+01 1.30E+05 2.55E+05 CE-144 4.89E+06 2.02E+06 2.62E+05 NO DATA 1.21E+06 1.34E+07 8.64E+05 PR-143 1.34E+04 5.31E+03 6.62E+02 NO DATA 3.09E+03 4.83E+05 2.14E+05 PR-144 4.30E-02 1.76E-02 2.18E-03 NO DATA 1.01E-02 1.75E+03 2.35E-04 ND-147 7.86E+03 8.56E+03 5.13E+02 NO DATA 5.02E+03 3.72E+05 1.82E+05 W-187 1.20E+01 9.76E@0 3.43E+00 NO DATA NO DATA 4.74E+04' 1.77E+05 NP-239 3.38E+02 3.19E+01 1.77E+01 NO DATA 1.00E+02 6.49E+04 1.32E+05
- 1.27 x 103
** Less than 8.00 x 10-15 O CLINTON-I 3-69 Rev.5-2/89 l
CPS-0DCM t TABLE 3.5-16 INHALATION PATHWAY FACTORS - R (ADULT) (mrem /yr per pCi/m3) l ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE H-3 NO DATA 1.26E+03* 1.26E+03 1.26E+03 1.26E+03 1.26E+03 1.26E+03 C-14 1.82E+04 3.41E+03 3.41E+03 3.41E+03 3.41E+03 3.41E+03 3.41E+03 k NA-24 1.02Et04 1.02E+04 1.02E+04 1.02E+04 1.02E+04 1.02E+04 1.02E+04 P-32 1.32E+06 7.71E+04 5.01E+04 NO DATA NO DATA NO DATA 8.64E+04 CR-51 NO DATA NO DATA 1.00E+02 5.95E+01 2.28E+01 1.44E+04 3.32E+03 MN-54 NO DATA 3.96E+04 6.30E+03 NO DATA 9.84E+03 1.40E+06 7.74E+04 MN-56 NO DATA 1.24E+00 1.83E-01 NO DATA 1.30E+00 9.44E+03 2.02E+04 FE-55 2.46E+04 1.70E+04 3.94E+03 NO DATA NO DATA 7.21E+04 6.03E+03 FE-59 1.18E+04 2.78E+04 1.06E+04 NO DATA NO DATA 1.02E+06 1.88E+05 CO-58 NO DATA 1.58E+03 2.07E+03 NO DATA NO DATA 9.28E+05 1.06E+05 CO-60 NO DATA 1.15E+04 1.48E+04 NO DATA NO DATA 5.97E+06 2.85E+05 NI-63 4.32E+05 3.14E+04 1.45E+04 NO DATA NO DATA 1.78E+05 1.34E+04 NI-65 1.54E+00 2.10E-01 9.12E-02 NO DATA NO DATA 5.60E+03 1.23E+04 CU-64 NO DATA 1.46E+00 6.15E-01 NO DATA 4.62E+00 6.78E+03 4.90E+04 ZN-65 3.24E+04 1.03E+05 4.66E+04 NO DATA 6.90E+04 8.64E+05 5.34E+04 ZN-69 3.38E-02 6.51E-02 4.52E-03 NO DATA 4.22E-02 9.20E+02 1.63E+01 BR-83 NO DATA NO DATA 2.41E+02 NO DATA NO DATA NO DATA 2.32E+02 BR-84 NO DATA NO DATA 3.13E+02 NO DATA NO DATA NO DATA ' 1.64E-03 BR-85 NO DATA NO DATA 1.28E+01 NO DATA NO DATA NO DATA LT8E-15** RB-86 NO DATA 1.35E+05 5.90E+04 NO DATA NO DATA NO DATA 1.66E+04 RB-88 NO DATA 3.87E+02 1.93E+02 NO DATA NO DATA NO DATA 3.34E-09 i RB-89 NO DATA 2.56E+02 1.70E+02 NO DATA NO DATA NO DATA 9.28E-12 l SR-89 3.04E+05 NO DATA 8.72E+03 NO DATA NO DATA 1.40E+06 3.50E+05 l SR-90 9.92E+07 NO DATA 6.10E+06 NO DATA NO DATA 9.60E+06 7.22E+05 l SR-91 6.19E+01 NO DATA 2.50E+00 NO DATA NO DATA 3.65E+04 1.91E+05 ' SR-92 6.74E+00 NO DATA 2.91E-01 NO DATA NO DATA 1.65E+04 4.30E+04 Y-90 2.09E+03 NO DATA 5.61E+01 NO DATA NO DATA 1.70E+05 5.06E+05 () -- - . CLINTON-I 3-70 Rev.5-2/89 h.._ . ._ .._._%
4 CPS-0DCM ~ k 1
,. . TABLE 3.5-16 (continued) -
l INHALATION PATHWAY FACTORS - R (ADULT) (mrem /yr per pCi/m3) ' ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE
]
Y-91m 2.61E-01 NO DATA 1.02E-02 NO DATA NO DATA 1.92E+03 1.33E+00 Y-91 4.62E+05 NO DATA 1.24E+04 NO DATA NO DATA 1.70E+06 3.85E+05 ! Y-92 1.03E+01 NO DATA 3.02E-01 NO DATA NO DATA 1.57E+04 7.35E+04 Y-93 9.44E+01 NO DATA 2.61E+00 NO DATA NO DATA 4.85E+04 4.22E+05 ZR-95 1.07E+05 3.44E+04 2.33E+04' NO DATA 5.42E+04 1.77E+06 1.50E+05 ZR-97 9.68E+01 1.96EM1 9.04E+00 NO DATA 2.97E+01 7.87E+04 5.23E+05 '4 i NB-95 1.41E% 4 7.82E+03 4.21E+03 NO DATA 7.74E+03 5.05E+05 1.04E+05 ' MO-99 NO DATA 1.21E+02 2.30E+01 NO DATA 2.91E+02 9.12E+04 2.48E+05 TC-99m 1.03E-03 2.91E-03 3.70E-02 NO DATA 4.42E-02 7.64EM 2 4.16E+03 TC-101 4.18E-05 6.02E-05 5.90E-04 NO DATA 1.08E-03 3.99E+02 1.09E-11 RU-103 1.53E+03 NO DATA 6.58E+02 NO DATA 5.83E+03 5.05E+05 1.10E+05 l RU-105 7.90E-01 NO DATA 3.11E -01 NO DATA 1.02E400 1.10E+04 4.82E+04 RU-106 6.91E+04 NO DATA 8.72E@3 NO DATA 1.34E+05 9.36E+06 9.12E+05 AG-110m 1.08E+04 1.00E+04 5.94E+03 NO DATA 1.97E+04 4.63E+06 3.02E+05 TE-125m 3.42EM3 1.58E+03 4.67E+02 1.05E+03 1.24E+04 3.14E+05 7.06E+04 TE- 127m 1.26E+04 5.77E403 1.57E+03 3.29E+03 4.58E+04 9.60E@5 1.50E+05 TE-127 1.40E+00 6.42E-01 3.10E-01 1.06E+00 5.10E+00 6.51E+03 5.74E+04 i TE-129m 9.76E+03 4.67E+03 1.58E+03 3.44E+03 3.66E+04 1.16E+06' 3.83E+05 ! l TE-129 4.98E-02 2.39E-02 1.24E-02 3.90E-02 1.87E-01 1.94E+03 1.57E+02 i TE-131m 6.99E+01 4.36E+01 2.90E+01 5.50E+01 3.09E+02 1.46E+05 5.56E+05 ! TE-131 1.11E-02 5.95E-03 3.59E-03 9.36E-03 4.37E-02 1.39E+03 1.84E+01 l l TE-132 2.60E+02 2.15E+02 1.62E@2 1.90E+02 1.46E+03 2.88E+05 5.10E+05 ! l .I-130 4.58E+03 1.34E+04 5.28E+03 1.14E+06 2.09E+04 NO DATA 7.69E+03 1-131 2.52E+04 3.58E+04 2.05E+04 1.19E% 7 6.13E+04 NO DATA 6.28E+03 I-132 1.16E+03 3.26E403 1.16EM3 1.14E+05 5.18E+03 NO DATA 4.06E402 I-133 8.64E+03 1.48E+04 4.52E+03 2.15E+06 2.58E+04 NO DATA 8.88E+03 I-134 6.44E+02 1.73E+03 6.15EM2 2.98E+04 2.75EM3 NO DATA 1.01E+00 CLINTON-I 3-71 Rev.5-2/89 1 _ _ _ _ _ . _ _ _ . _ _ . . _ _ _ _ _ _ _ _ _ _ _ _ _ _ . . _ . - . _ . -._ - 1
CPS-0DCM l l TABLE 3.5-16 (continued) l i INHALATION PATHWAY FACTORS - R (ADULT) (mrem /yr per pCi/m3) l l l ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI
^
ISOTOPE l I-135 2.68E+03 6.98E+03 2.57E+03 4.48E+05 1.11E+04 NO DATA 5. 25EM3 i CS-134 3.73E+05 8.48E+05 7.28E+05 NO DATA 2.87E+05 9.76E+04 1.04E+04 J CS-136 3.90E+04 1.46E+05 1.10E+05 NO DATA 8.56E+04 1.20E+04 1.17E+04 CS-137 4.78E+05 6.21E+05 4.28EM5 NO DATA 2.22E+05 7.52E+04 8.40E+03 CS-138 3.31EM 2 6.21E+02 3.24E+02 NO DATA 4.80E+02 4.86E+01 1.86E-03 BA-139 9.36E-01 6.66E-04 2.74E-02 NO DATA 6.22E-04 3.76E+03 8.96E+02 BA-140 3.90E+04 4.90E+01 2.57E+03 NO DATA 1.67E+01 1.27E+06 2.18E+05 BA-141 1.00E-01 7.53E-05 3.36E-03 NO DATA 7.00E-05 1.94E+03 1.16E-07 BA-142 2.63E-02 2.70E-05 1.66E-03 NO DATA 2.29E-05 1.19E+03 1.57E-16 LA-140 3.44E+02 1.74E+02 4.58E+01 NO DATA NO DATA 1.36E+05 4.58E+05 LA-142 6.83E-01 3.10E-01 7.72E-02 NO DATA NO DATA 6.33E+03 2.11E+03 CE-141 1.99E+04 1.35E+04 1.53E+03 NO DATA 6.26E+03 3.62E+05 1.20E+05 v CE-143 1.86E+02 1.38E+02 1.53E+01 NO DATA 6.08E+01 7.98E+04 2.26E+05 CE-144 3.43E+06 1.43E+06 1.84E+05 NO DATA 8.48E+05 7.78E+06 8.16E+05 PR-143 9.36E+03 3.75E+03 4.64E+02 NO DATA 2.16E+03 2.81E+05 2.00E+05 PR-144 3.01E-02 1.25E-02 1.53E-03 NO DATA 7.05E-03 1.02E+03 2.15E-08 ND-147 5.27E+03 6.10E+03 3.65E+02 NO DATA 3.56E+03 2.21E+05 1.73E+05 W-187 8.48E+00 7.08E+00 2.48E+00 NO DATA NO DATA 2.90E+04' 1.55E+05 NP-239 2.30E+02 2.26E+01 1.24E+01 NO DATA 7.00E+01 3.76E+04 1.19E+05 3
- 1.26 x 10
** Less than 8.00 x10-15 O
CLINTON-I 3-72 Rev.5-2/89 1 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ .]
CPS-0DCM ) TABLE 3.5-17 COW MILK PATHWAY FACTORS - R (INFANT) (m2 mrem /yr per pCi/sec) ! l ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI I ISOTOPE ! 11 - 3 NO DATA 2.38E+03* 2.38E+03* 2.38E+03* 2.38E+03* 2.38E+03* 2.38E+03*' C-14 3.23E+06* 6.89E+05* 6.89E+05* 6.89E+05* 6.89E+05* 6.89E+05* 6.89E+05* q NA-24 1.55E+07** 1.55E+07 1.55E%7 1.55E+07 1.55E+07 1.55E+07 1.55E+07 ' P-32 1.60E+11 9.41EM9 6.20E+09 NO DATA NO DATA NO DATA 2.16E+09 l CR-51 NO DATA NO DATA 1.61E+05 1.05E+05 2.29E+04 2.04E+05 4.69E406 ! MN-54 NO DATA 3.90E+07 8.84E+06 NO DATA 8.64E+06 NO DATA 1.43E+07 MN-56 NO DATA 3.12E-02 5.39E-03 NO DATA 2.69E-02 NO DATA 2.84E+00 I FE-55 1.35E+08 8.72E+07 2.33E+07 NO DATA NO DATA 4.26E+07 1.11E+07 TE-59 2.25E+08 3.92E+08 1.55E+08 NO DATA NO DATA 1.16E408 1.87E+08 C0-58 NO DATA 2.43E+07 6.06E+07 NO DATA NO DATA NO DATA 6.05E+07 C0-60 NO DATA 8.82E+07 2.08E+08 NO DATA NO DATA NO DATA 2.10E+08 NI-63 3.50E+10 2.16E+09 1.21E+09 NO DATA NO DATA NO DATA 1.08E408 NI-65 3.52E+00 3.98E-01 1.81E-01 NO DATA NO DATA NO DATA 3.03E+01 CU-64 NO DATA 1.84E+05 8.52E+04 NO DATA 3.11E+05 NO DATA 3.78E+06 ZN-65 5.55E+09 1.91E+10 8.78E+09 NO DATA 9.23E+09 NO DATA 1.61E+10 ZN-69 1.94E-11 3.49E-11 2.60E-12 NO DATA 1.45E-11 NO DATA 2.85E-09 BR-83 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA BR-84 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA ' NO DATA BR-85 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA v RB-86 NO DATA 2.23E+10 1.10E+10 NO DATA NO DATA NO DATA 5.70E+08 RB-88 NO DATA 1.88E-44 1.03E-44 NO DATA NO DATA NO DATA 1.83E-44 i RB-89 NO DATA 3.43E-52 2.36E-52 NO DATA NO DATA NO DATA 1.17E-52 SR-89 1.26E+10 NO DATA 3.61E+08 NO DATA NO DATA NO DATA 2.59E+08 SR-90 1.22E+11 NO DATA 3.10E+10 NO DATA NO DATA NO DATA 1.52E+09 SR-91 2.71E+05 NO DATA 9.76E+03 NO DATA NO DATA NO DATA 3.20E+05 l SR-92 4.68E+00 NO DATA 1.74E-01 NO DATA NO DATA NO DATA 5.05E+01 ; I Y-90 6.83E+02 NO DATA 1.83E+01 NO DATA NO DATA NO DATA 9.43E+05 l CLINTON-I 3-73 Rev.5-2/89 L -
CPS-0DCM I TABLE 3.5-17 (continued) h COW MILK PATHWAY FACTORS - R (INFANT) (m2 mrem /yr per pCi/sec) ORGAN: BONE LIVEE T. BODY TRYROID KIDNEY LUNG GI-LLI ISOTOPE 1 Y-91m 6.09E-19 NO DATA 2.08E-20 NO DATA NO DATA NO DATA 2.03E-15 Y-91 7.33E+04 NO DATA 1.95E+03 NO DATA NO DATA NO DATA 5.26E+06 Y-92 5.35E-04 NO DATA 1.50E-05 NO DATA NO DATA NO DATA 1.02E+01 Y-93 2.14E+00 NO DATA 5.83E-02 NO DATA NO DATA NO DATA 1.69E+04 ZR-95 6.82E+03 1.66E+03 1.18E+03 NO DATA 1.79E+03 NO DATA 8.28E+05 ZR-97 4.03E+00 6.96E-01 3.16E-01 NO DATA 7.01E-01 NO DATA 4.41E+04 NB-95 5.93E+05 2.44E+05 1.41E+05 NO DATA 1.75E+05 NO DATA 2.06E+08 M0-99 NO DATA 2.07E+08 4.04E+07 NO DATA 3.10E+08 NO DATA 6.83E+07 TC-99m 2.75E+01 5.66E+01 7.29E+02 NO DATA 6.09E+02 2.96E+01 1.64E+04 TC-101 2.72E-59 3.42E-59 3.39E-58 NO DATA 4.07E-58 1.87E-59 5.81E-57 RU-103 8.67E+03 NO DATA 2.92E+03 NO DATA 1.81E+04 NO DATA 1.06E+05 RU-105 8.00E-03 NO DATA 2.70E-03 NO DATA 5.88E-02 NO DATA 3.18E+00 g RU-106 1.91E+05 NO DATA 2.38E+04 NO DATA 2.26E+05 NO DATA 1.45E+06 AG-110m 3.85E+08 2.81E+08 1.86E+08 NO DATA 4.02E+08 NO DATA 1.46E+10 TE-125m 1.51E+08 5.05E+07 2.04E+07 5.08E+07 NO DATA NO DATA 7.19E+07 TE-127m 4.22E+08 1.40E+08 5.10E+07 1.22E+08 1.04E+09 NO DATA 1.70E+08 TE-127 6.31E+03 2.11E+03 1.39E+03 5.13E+03 1.58E+04 NO DATA 1.36E+05 TE-129m 5.56E+08 1.91E+08 8.56E+07 2.14E+08 1.39E+09 NO DATA ' 3.32E+08 TE-129 2.71E-09 9.34E-10 6.33E-10 2.27E-09 6.75E-09 NO DATA 2.17E-07 TE-131m 3.37E+06 1.36E+06 1.12E+06 2.75E+06 9.35E+06 NO DATA 2.29E+07 TE-131 3.48E-32 1.29E-32 9.78E-33 3.11E-32 8.91E-32 NO DATA 1.41E-30 TE-132 2.12E+07 1.05E+07 9.80E+06 1.55E+07 6.57E+07 NO DATA 3.89E+07 I-130 3.53E+06 7.76E+06 3.12E+06 8.70E+08 8.53E+06 NO DATA 1.66E+06 I-131 2.71E+09 3.19E+09 1.40E+09 1.05E+12 3.73E+09 NO DATA 1.14E+08 I-132 1.43E400 2.90E+00 1.03E+00 1.36E+02 3.24E+00 NO DATA 2.35E+00 I-133 3.63E+07 5.28E+07 1.55E+07 9.60E+09 6.21E+07 NO DATA 8.93E+06 I-134 1.64E-11 3.36E-11 1.20E-11 7.86E-10 3.76E-11 NO DATA 3.48E-11 CLINTON-I 3-74 Rev.5-2/89
CPS-0DCM TABLE 3.5-17 (continued) g COW MILK PATHWAY FACTORS - R C (INFANT) l (m2 mrem /yr perp Ci/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE _ I-135 1.13E+05 2.24E+05 8.18E+04 2.01E+07 2.50E+05 NO DATA 8.12E%4 CS-134 3.65E+10 6.81E+10 6.88E+09 NO DATA 1.75E+10 7.19E+09 1.85E+08 CS-136 1.97E+09 5.81E+09 2.17E+09 NO DATA 2.31E+09 4.73E+08 8.82E+07 CS-137 5.15E+10 6.03E+10 4.27E+09 NO DATA 1.62E+10 6.55E+09 1.89E+08 CS-138 8.06E-23 1.31E-22 6.35E-23 NO DATA 6.53E-23 1.02E-22 2.09E-22 BA-139 4.29E-07 2.84E-10 1.24E-08 NO DATA 1.71E-10 1.72E-10 2.72E-05 3A-140 2.45E+08 2.45E+05 1.26E+07 NO DATA 5.72E+04 1.50E+05 5.92E+07 BA-141 4.16E-45 2.85E-48 1.31E-46 NO DATA 1.71E 1.73E-48 5.08E-44 BA-142 2.32E-79 1.93E-82 1.14E-80 NO DATA 1.11E-82 1.17E-82 9.56E-79 LA-140 4.05E+01 1.60E+01 4.11E+00 NO DATA NO DATA NO DATA 1.88E+05 LA-142 1.73E-10 6.34E-11 1.52E-11 NO DATA NO DATA NO DATA 1.08E-05 CE-141 4.34EM4 2.65E+04 3.12E+03 NO DATA 8.17EM3 NO DATA 1.37E+07 CE-143 3.98E+02 2.64EM5 3.01E+01 NO DATA 7.69E+01 NO DATA 1.54E+06 CE-144 2.34E+06 9.56E+05 1.31E+05 NO DATA 3.87E+05 NO DATA 1.34E+08 PR-143 1.49E+03 5.56E+02 7.37E+01 NO DATA 2.07E+02 NO DATA 7.85E+05 PR-144 6.27E-53 2.43E-53 3.16E-54 NO DATA 8.79E-54 NO DATA 1.13E-48 ND-147 8.79E+02 9.03E+02 5.53E+01 NO DATA 3.48E+02 NO DATA 5.72E+05 W-187 6.10E+04 4.24E+04 1.46E+04 NO DATA NO DATA NO DATA ' 2.49EM6 NP-239 3.64E+01 3.26EMO 1.84E+00 NO DATA 6.49E+00 NO DATA 9.41E+04
- mrem /yr per pCi/m3 7
** 1.55 x 10 O
CLINTON-I 3-75 Rev.5-2/89
CPS-0DCM l l l l l TABLE 3.5-18 l
-() COW MILK PATHWAY FACTORS - R,Cij(CHILD) ]
(m2 mrem /yr per Ci/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ! ISOTOPE H-3 NO DATA 1.57E+03* 1.57E403* 1.57EM3* 1.57E+03* 1.57E+03* 1.57E+03* C-14 1.65E+06* 3.29E+05* 3.29E+05* 3.29E+05* 3.29E+05* 3.29E+05* 3 . ',.9 E+0 5
- NA-24 8.93E406** 8.93E+06 8.93E+06 8.93E+06 8.93E+06 8.93E+06 8.93E+06 P-32 7.79E+10 3.64E+09 3.00E+09 NO DATA NO DATA NO DATA 2.15E+09 CR-51 NO DATA NO DATA 1.01E+05 5.63E+04 1.54E+04 1.03E+05 5.38E+06 MN-54 NO DATA 2.10E+07 5.59E+06 NO DATA 5.88E+06 NO DATA 1.76E+07 MN-56 NO DATA 1.28E-02 2.88E-03 NO DATA 1.54E-02 NO DATA 1.85E+00 FE-55 1.12E+08 5.94E+07 1.84E+07 NO DATA NO DATA 3.36E+07 1.10E+07 FE-59 1.20E+08 1.95E+08 9.71E+07 NO DATA NO DATA 5.65E+07 2.03E+08 CO-58 NO DATA 1.21E+07 3.71E+07 NO DATA NO DATA NO DATA 7.08E+07 Co-60 NO DATA 4.32E+07 1.27E+08 NO DATA NO DATA NO DATA 2.39E+08 p NI-63 2.97E+10 1.59E409 1.01E+09 NO DATA NO DATA NO DATA 1.07E+08 O ,
NI-65 1.65E+00 1.56E-01 9.10E-02 NO DATA NO DATA NO DATA 1.91E+01 CU-64 NO DATA 7.40E+04 4.47E404 NO DATA 1.79E+05 NO DATA 3.47E+06 l' ZN-65 4.13E+09 1.10E+10 6.83E+09 NO DATA 6.92E+09 NO DATA 1.9?E409 ZN-69 9.11E-12 1.32E-11 1.22E-12 NO DATA 7.99E-12 NO DATA 8.30E-10 ; BR-83 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA BR-84 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA ' NO DATA BR-85 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA RB-86 NO DATA 8.78E+09 5.40E+09 NO DATA NO DATA NO DATA 5.65E+08 RB-88 NO DATA 7.16E-45 4.98E-45 NO DATA NO DATA NO DATA 3.51E-46 l RB-89 NO DATA 1.40E-52 1.25E-52 NO DATA NO DATA NO DATA 1.22E-54 SR-89 6.63E+09 NO DATA 1.89E+08 NO DATA NO DATA NO DATA 2.57E+08 SR-90 1.12E+11 NO DATA 2.84E+10 NO DATA NO DATA NO DATA 1.51E+09 l O CLINTON-I 3-76 Rev.5-2/89
- - - - - - - - - - - - - - - - --- 1
CPS-0DCM I TABLE 3.5-18 (continued) { COW MILK PATHWAY FACTORS - R (CHILD) (m2 mrem /yr per pCi/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE q SR-91 1.30E+05 NO DATA 4.89E+03 NO DATA NO DATA NO DATA 2.86E+05 SR-92 2.20E+00 NO DATA 8.83E-02 NO DATA NO DATA NO DATA 4.1?E+01 Y-90 3.23E+02 NO DATA 8.65E+00 NO DATA NO DATA NO DATA 9.20E+05 Y-91m 2.88E-19 NO DATA 1.05E-20 NO DATA NO DATA NO DATA 5.63E-16 Y-91 3.90E+04 NO DATA 1.04E+03 NO DATA NO DATA NO DATA 5.20E+06 Y-92 2.53E-04 NO DATA 7.?.3E-06 NO DATA NO DATA NO DATA 7.30EMO Y-93 1.01E+00 NO DATA 2.76E-02 NO DATA NO DATA "O DATA 1.50E+04 ZR-95 3.84E+03 8.44E+02 7.51E+02 NO DATA 1.21E+03 h0 DATA 8.80E+05 ZR-97 1.92E+00 2.78E-01 1.64E-01 NO DATA 3.99E-01 NO DATA 4.21E+04 NB-95 3.18E+05 1.24E+05 8.84EM4 NO DATA 1.16E+05 NO DATA 2.29E+08 MO-99 NO DATA 8.15E+07 2.02E+07 NO DATA 1.74E+08 NO DATA 6.74EM7 TC-99m 1.32E+01 2.58E+01 4.28E+02 NO DATA 3.75E+02 1.31E+01 1.47E+04 I TC-101 1.28E-59 1.34E-59 1.70E-58 NO DATA 2.29E-58 7.08E-60 4.26E-59 RU-103 4.29E+03 NO DATA 1.65E+03 NO DATA 1.08E+04 NO DATA 1.11E+05 RU-105 3.80E-03 NO DATA 1.38E-03 NO DATA 3.34E-02 NO DATA 2.48E+00 RU-106 9.25E+04 NO DATA 1.15E+04 NO DATA 1.25E+05 NO DATA 1.44E+06 l AG-110m 2.09E+08 1.41EM 8 1.13E+08 NO DATA 2.63E+08 NO DATA 1.68E+10 TE-125m 7.39E+07 2.00E+07 9.85E+06 2'.07E M 7 NO DATA NO DATA ' 7.13E+07 TE-127m 2.08E+08 5.61EM7 2.47EM7 4.98E+07 5.94E+08 NO DATA 1.69EM8 TE-127 2.97E+03 8.01E+02 6.37E+02 2.06E+03 8.45E+03 NO DATA 1.16E+05 TE-129m 2.71E+08 7.58E+07 4. 21EM7 8.74E+07 7.97E+08 NO DATA 3.31E+08 TE-129 1.28E-09 3.57E-10 3.04E-10 9.12E-10 3.74E-09 NO DATA 7.96E-08 TE-131m 1.60E+06 5.53E+05 5.88E+05 1.14E+06 5.35E+06 NO DATA 2.24E+07 TE-131 1.64E-32 5.01E-33 4.89E-33 1.26E-32 4.97E-32 NO DATA 8.63E-32 l TE-132 1.03E+07 4.56E+06 5.51E+06 6.64E+06 4.23E+07 NO DATA 4.59E+07 l I-130 1.72E+06 3.47E+06 1.79E+06 3.82E+08 5.19E+06 NO DATA 1.62E+06 l 'I-131 1.30E+09 1.31E+09 7.44E+08 4.33E+11 2.15E+09 NO DATA 1.17E+08 CLINTON-I 3-77 Rev.5-2/89 L
CPS-ODCM TABLE 3.5-18 (continued) (] COW MILK PATHWAY FACTORS - R 13(CHILD) (m2 mrem /yr per pCi/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE _ I-132 6.91E-01 1.27E%0 5.84E-01 5.89E+01 1.94E+00 NO DATA 1.49E%0 I-133 1.72E+07 2.12E+07 8.03E+06 3.94E+09 3.54E+07 NO DATA 8.56E+06 I-134 7.92E-12 1.47E-11 6.77E-12 3.38E-10 2.25E-11 NO DATA 9.75E-12 I-135 5.43E@ 4 9.77E+04 4.62E+04 8.65E+06 1.50E+05 NO DATA 7.44E+04 CS-134 2.27E+10 3.72E+10 7.85E+09 NO DATA 1.15E+10 4.14E+09 2.01E+08 CS-136 1.01E+09 2.78E+09 1.80E+09 NO DATA 1.48E+09 2.21E+08 9.76E+07 > CS-137 3.23E+10 3.09E+10 4.56E+09 NO DATA 1.01E+10 3.63E+09 1.94E+08 L CS-138 3.82E-23 5.31E-23 3.37E-23 NO DATA 3.74E-23 4.02E-24 2.45E-23 l BA-139 2.01E-07 1.08E-10 5.84E-09 NO DATA 9.39E-11 6.33E-11 1.16E-05 BA-140 1.18E+08 1.03E+05 6.84E+06 NO DATA 3.37E+04 6.12E+04 5.94E407 BA-141 1.96E-45 1.10E-48 6.38E-47 NO DATA 9.50E-49 6.45E-48 1.12E-45 BA-142 1.10E-79 7.93E-83 6.15E-81 NO DATA 6.41E-83 4.66E-83 1.44E-81 LA-140 1.94E+01 6.78E+00 2.11E+00 NO DATA NO DATA NO DATA 1.89E+05 ' LA-142 8.23E-11 2.62E-11 8.21E-12 NO DATA NO DATA NO DATA 5.20E-06 CE-141 4.94E+04 1.09E@4 1.62E+03 NO DATA 4.78E+03 NO DATA 1.36E+07 CE-143 1.87E+02 1.02EM5 1.47E+01 NO DATA 4.26E+01 NO DATA 1.49EM6 CE-144 1.63E+06 5.10E+05 8.68E+04 NO DATA 2.82E+05 NO DATA 1.33E+08 PR-143 7.19E@2 2.16E+02 3.57E+01 NO DATA 1.17E+02 NO DATA 7.76E+05 PR-144 2.94E-53 9.10E-54 1.48E-54 NO DATA 4.81E-54 NO DATA 1.96E-50 ND-147 4.44EM2 3.59E+02 2.78E+01 NO DATA 1.97E+02 NO DATA 5.69E+05 W-187 2.88E+04 1.71EM4 7.66E+03 NO DATA NO DATA NO DATA 2.40E+06
'iP-239 1. 72EMI 1.24E+00 8.69E-01 NO DATA 3.58E+00 NO DATA 9.15EM4
- mrem /yr per p Ci/m3
( ** 8.93 x 10 6 l CLINTON-I 3-78 Rev.5-2/89 L ----_ - . - - - - - . - - -----------------_-_---d
CPS-ODCM - TABLE 3.5-19
~T C '
(O COW MILK PATHWAY FACTORS - Raij (TEEN) ! (m2 mrem /yr per pCi/sec) l l ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI l ISOTOPE I H-3 NO DATA 9.92E+02* 9.92E+02* 9.92E+02* 9.92E+02* 9.92E+02* 9.92E+02* C-14 6.70E+05* 1.34E+05* 1.34E+05* 1.34E+05* 1.34E+05* 1.34E+05* 1.34E+05* NA-24 4.29EM 6** 4.29E+06 4.29E+06 4.29E+06 4.29E+06 4.29E+06 4.29E+06 l P-32 3.15E+10 1.95E+09 1.22E+09 NO DATA NO DATA NO DATA 2.64E+09 CR-51 NO DATA NO DATA 5.00E+04 2.78E+04 1.10E+04 7.14E+04 8.41E+06 MN-54 NO DATA 1.40E+07 2.78E+06 NO DATA 4.19E+06 NO DATA 2.88E+07 MN-56 NO DATA 7.32E-03 1.30E-03 NO DATA 9.26E-03 NO DATA 4.82E-01 ; FE-55 4.46E+07 3.16E+07 7.38E+06 NO DATA NO DATA 2.01E+07 1.37E+07 FE-59 5.18E%7 1.21E+08 4.67E+07 NO DATA NO DATA 3.81E+07 2.86E+08 i C0-58 NO DATA 7.98E+06 1.84E+07 NO DATA NO DATA NO DATA 1.10E+08 C0-60 NO DATA 2.78E+07 6.26E+07 NO DATA NO DATA NO DATA 3.62E+08 NI-63 1.18E+10 8.34E+08 4.00E+08 NO DATA NO DATA NO DATA 1.33E+08 NI-65 6.79E-01 8.67E-02 3.95E-02 NO DATA NO DATA NO DATA 4.70E+00 CU-64 NO DATA 4.20E+04 1.97E+04 NO DATA 1.06E+05 NO DATA 3.26E+06 ZN-65 2.11E+09 7.32E+09 3.41E+09 NO DATA 4.68E+09 NO DATA 3.10E+09 l ZN-69 3.70E-12 7.06E-12 4.94E-13 NO DATA 4.61E-12 NO DATA 1.30E-11 :l BR-83 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA l BR-84 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA - NO DATA j l BR-85 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA RB-86 NO DATA 4.74E+09 2.23E+09 NO DATA NO DATA NO DATA 7.01E+08 l RB-88 NO DATA 3.90E-45 2.08E-45 NO DATA NO DATA NO DATA 3.34E-52 RB-89 NO DATA 7.98E-53 5.64E-53 NO DATA NO DATA NO DATA 1.22E-61 l SR-89 2.68E+09 NO DATA 7.67E+07 NO DATA NO DATA NO DATA 3.19E%8 SR-90 6.62E+10 NO DATA 1.64E+10 NO DATA NO DATA NO DATA 1.86E+09 j l SR-91 5.27E+04 NO DATA 2.10EM3 NO DATA NO DATA NO DATA 2.39E+05
- SR-92 9.03E-01 NO DATA 3.85E-02 NO DATA NO DATA NO DATA 2.30E+01 1 l Y-90 1.31EM2 NO DATA 3.53E+00 NO DATA NO DATA NO DATA 1.08E+06 I (3 a
(.) ]
'1 l
CLINTON-I 3-79 Rev.5-2/89 ! _ _ _ _ _ _ _ _ _ _ - - - - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ l
CPS-ODCM TABLE 3.5-19 (continued)
;] COW MILK PATHWAY FACTORS - R,C (TEEN)
(m mrem /yr per pCi/sec) t l ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNC GI-LLI ISOTOPE Y-91m 1.18E-19 NO DATA 4.49E-21 NO DATA NO DATA NO DATA 5.55E-18 Y-91 1.58E+04 NO DATA 4.24E+02 NO DATA NO DATA NO DATA 6.48E+06 Y-92 1.03E-04 NO DATA 2.97E-06 NO DATA NO DATA NO DATA 2.82E+00 Y-93 4.10E-01 NO DATA 1.12E-02 NO DATA NO DATA NO DATA 1.25EM4 ZR-95 1.65E+03 5.20E+02 3.58E+02 NO DATA 7.64E+02 NO DATA 1.20E+06 ZR-97 7.87E-01 1.56E-01 7.17E-02 NO DATA 2.36E-01 NO DATA 4.22E+04 NB-95 1.41E+05 7.81E+04 4.30E+04 NO DATA 7.57E+04 NO DATA 3.34E%8 M0-99 NO DATA 4.46E+07 8.50E+06 NO DATA 1.02E+08 NO DATA 7.98E+07 TC-99m 5.74E+00 1.60E+01 2.08E+02 NO DATA 2.39E+02 8.89E+00 1.05E+04 TC-101 5.22E-60 7.42E-60 7.29E-59 NO DATA 1.34E-58 4.52E-60 1.27E-66 RU-103 1.81E+03 NO DATA 7.73E+02 NO DATA 6.37E+03 NO DATA 1.51E+05 ( RU-105 1.56E-03 NO DATA 6.06E-04 NO DATA 1.97E-02 NO DATA 1.26E+00 RU-106 3.75EM4 NO DATA 4.73E403 NO DATA 7.23E+04 NO DATA 1.80E+06 AG-110m 9.64E+07 9.12E407 5.55E+07 NO DATA 1.74E+08 NO DATA 2.56E+10 TE-125m 3.01E+07 1.08E+07 4.02E+06 8.41E+06 NO DATA NO DATA 8.88E+07 TE-127m 8.43E+07 2.99E+07 1.00E+07 2.01E+07 3.42EM8 NO DATA 2.10E+08 TE-127 1.21E+03 4.28E+02 2.60E+02 8.33E+02 4.89E+03 NO DATA 9.33E+04 TE-129m 1.10E+08 4.09E+07 1.74E+07 3.56E+07 4.61E+08 NO DATA - 4.14E+08 TE-129 5.18E-10 1.93E-10 1.26E-10 3.70E-10 2.17E-09 NO DATA 2.83E-09 TE-131m 6.56E+05 3.15E+05 2.63E+05 4.73E+05 3.28E+06 NO DATA 2.53E+07 TE-131 6.70E-33 2.76E-33 2.09E-33 5.16E-33 2.93E-32 NO DATA 5.50E-34 TE-132 4.29E+06 2.72E+06 2.56E+06 2.87E+06 2.61E+07 NO DATA 8.61EM7 , 1-130 7.33E+05 2.12E+06 8.47E+05 1.73E+08 3.27E+06 NO DATA 1.63E+06 I-131 5.36E+08 7.50E+08 4.03E+08 2.19E+11 1.29E+09 NO DATA 1.48E+08 I-132 2.90E-01 7.59E-01 2.72E-01 2.56E+01 1.20E+00 NO DATA 3.31E-01 I-133 7.06E+06 1.20E+07 3.65E+06 1.67E+09 2.10E+07 NO DATA 9.06E406 I-134 3.34E-12 8.86E-12 3.18E-12 1.48E-10 1.40E-11 NO DATA 1.17E-13 l CLINTON-I 3-80 Rev.5-2/89 l
~
CPS-0DCM TABLE 3.5-19 (continued) O Cowx1txPirnwirriCroas-n:13<r8EN) (m2 mrem /yr per pCi/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE I-135 2.29E+04 5.90E+04 2.19EM4 3.80E+06 9.32EM4 NO DATA 6.54E+04 E CS-134 9.79E+09 2.30E+10 1.07E+10 NO DATA 7.32E+09 2.80E+09 2.87E+08 CS-136 4.48E+08 1.76E+09 1.18E409 NO DATA 9.59E+08 1.51E+08 1.42E+08 CS-137 1.33E+10 1.77E+10 6.18E+09 NO DATA 6.03E+09 2.34E+09 2.52EM8 CS-138 1.58E-23 3.03E-23 1.51E-23 NO DATA 2.23E-23 2.60E-24 1.37E-26 BA-139 8.20E-08 5.77E-11 2.39E-09 NO DATA 5.44E-11 3.98E-11 7.31E-07 BA-140 4.85E+07 5.95E+04 3.13E+06 NO DATA 2.02E+04 4.00E+04 7.49E+07 BA-141 7.98E-46 5.96E-49 2.67E-47 NO DATA 5.53E-49 4.08E-49 1.70E-51 BA-142 4.54E-80 4.54E-83 2.80E-81 NO DATA 3.85E-83 3.02E-83 1.40E-91 LA-140 8.11E+00 3.98E+00 1.06E+00 NO DATA NO DATA NO DATA 2.29E+05 LA-142 3.42E-11 1.52E-11 3.78E-12 NO DATA NO DATA NO DATA 4.62E-07 CE-141 8.88E+03 5.93E+03 6.81E+02 NO DATA 2.79E+03 NO DATA 1.70E+07 CE-143 7.64E+01 5.55E+04 6.21E+00 NO DATA 2.49E%1 NO DATA 1.67E+06 CE-144 6.61E+05 2.73E+05 3.55E+04 NO DATA 1.63E+05 NO DATA 1.66EM 8 PR-143 2.91EM 2 1.16E+02 1.45EMI NO DATA 6.75E+01 NO DATA 9.57EM5 PR-144 1.19E-53 4.88E-54 6.04E-55 NO DATA 2.80E-54 NO DATA 1.31E-56 ND-147 1.81E+02 1.970+02 1.18E+01 NO DATA 1.16E+02 NO DATA 7.10E+05 W-187 1.19E+04 9.72E403 3.41E+03 NO DATA NO DATA NO DATA ' 2.63E+06 NP-239 6.99E+00 6.59E-01 3.66E-01 NO DATA 2.07E+00 NO DATA 1.06E+05
- mre.n/yr per pCi/m3 6
** 4.29 x 10 O
CLINTON-I 3-81 Rev.5-2/89
CPS-0DCM TABLE 3.5-20 U<~s COW MILK PATHWAY FACTORS - R (ADULT) (m2 mrem /yr per pCi/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE H-3 NO DATA 7.62E+02* 7.62E+02* 7.62E+02* 7.62E+02* 7.62E+02* 7.62EM2* C-14 3.63E+05* 7.26E+04* 7.26E+04* 7.26E+04* 7.26E+04* 7.26E+04* 7.26E+04* , NA-24 2.46E+06** 2.46E+06 2.46E+06 2.46E+06 2.46E+06 2.46E+06 2.46E%6 P-32 1.71E+10 1.06E+09 6.61E+08 NO DATA NO DATA NO DATA 1.92EM9 l CR-51 NO DATA NO DATA 2.85E+04 1.70E+04 6.27EM3 3.78E+04 7.16E+06 MN-54 NO DATA 8.41E+06 1.60E+06 NO DATA 2.50E+06 NO DATA 2.58E+07 , 1 MN-56 NO DATA 4.14E-03 7.34E-04 NO DATA 5.26E-03 NO DATA 1.32E-01 FE-55 2.51E+07 1.73E+07 4.04E+06 NO DATA NO DATA 9.68E+06 9.95E+06 FE-59 2.97E+07 6.99E+07 2.68E+07 NO DATA NO DATA 1.95E407 2.33E+08 f i CO-58 NO DATA 4.72E+06 1.06E+07 NO DATA NO DATA NO DATA 9.57EM7 CO-60 NO DATA 1.64E+07 3.62E+07 NO DATA NO DATA NO DATA 3.08E+08 L NI-63 6.73E+09 4.67E408 2.26E+08 NO DATA NO DATA NO DATA 9.74E+07 NI-65 3.70E-01 4.81E-02 2.19E-02 NO DATA NO DATA NO DATA 1.22E+00 I CU-64 NO DATA 2.36E+04 1.11E+04 NO DATA 5.94E+04 NO DATA 2.01E+06 ZN-65 1.37E+09 4.37E+09 1.98E+09 NO DATA 2.93E+09 NO DATA 2.75E+09 l ZN-69 2.01E-12 3.84E-12 2.67E-13 NO DATA 2.50E-12 NO DATA 5.77E-13 I BR-83 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA , NO DATA BR-84 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA BR-85 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA RB-86 NO DATA 2.60E+09 1.21E+09 NO DATA NO DATA NO DATA 5.12E+08 RB-88 NO DATA 2.15E-45 1.14E-45 NO DATA NO DATA NO DATA 2.97E-56 RB-89 NO DATA 4.49E-53 3.16E-53 NO DATA NO DATA NO DATA 2.61E-66 SR-89 1.45E+09 NO DATA 4.16E+07 NO DATA NO DATA NO DATA 2.33E+08 SR-90 4.68E+10 NO DATA 1.15E+10 NO DATA NO DATA NO DATA 1.35E+09 SR-91 2.87E+04 NO DATA 1.16E+03 NO DATA NO DATA NO DATA 1.37E405 SR-92 4.92E-01 NO DATA 2.13E-02 NO DATA NO DATA NO DATA 9.76E+00 Y-90 7.10E+01 NO DATA 1.90E+00 NO DATA NO DATA NO DATA 7.53E+05 O , l CLINTON-I 3-82 Rev.5-2/89
CPS-0DCM TABLE 3.5-20 (continued) COW MILK PATHWAY FACTORS - R 13 M T)- (m2 mrem /yr pery Ci/sec) ORGAN: BONE. LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE _ Y-91m 6.42E-20 NO DATA 2.49E-21 NO DATA NO DATA NO DATA 1.89E-l9 Y-91 8.60E+03 NO DATA 2.30E+02 NO DATA NO DATA NO DATA 4 . 7 3 E+0 s', ! Y-92 5.57E-05 NO DATA 1.63E-06 NO DATA NO DATA NO DATA 9.75E-01 Y-93 2.22E-01 NO DATA 6.12E-03 NO DATA NO DATA NO DATA 7.03E+03 ZR-95 9.45E+02 3.03E+02 2.05E+02 NO DATA 4.76E+02 NO DATA 9.61E+05 ZR-97 4.32E-01 8.71E-02 3.98E-02 NO DATA 1.32E-01 NO DATA 2.70E+04 NB-95 8.25E+04 4.59E+04 2.47E+04 NO DATA 4.54E+04 NO DATA 2.79E+08 MO-99 NO DATA 2.48E+07 4.72E+06 NO DATA 5.61E+07 NO DATA 5.74E+07 TC-99m 3.31E+00 9.35E+00 1.19E+02 NO DATA 1.42E+02 4.58E+00 5.53EM3 TC-101 2.85E-60 4.11E-60 4.03E-59 NO DATA 7.41E-59 2.10E-60 1.24E RU-103 1.02E+03 NO DATA 4.39E+02 NO DATA 3.89E+03 NO DATA 1.19E+05 RU-105 8.52E-04 NO DATA 3.36E-04 NO DATA 1.10E-02 NO DATA 5.21E-01 RU-106 2.04E+04 NO DATA 2.58E+03 NO DATA 3.94E+04 NO DATA 1.32E+06 AG-110m 5.82EM7 5.39E+07 3.20E+07 NO DATA 1.06E+08 NO DATA 2.20E+10 TE-125m 1.63E+07 5.91E+06 2.19E+06 4.91E+06 6.64E+07 NO DATA 6.52E+07 l l TE-127m 4.58E+07 1.64E+07 5.58E+06 1.17E+07 1.86E+08 NO DATA 1.53E+08 TE-127 6.52E+02 1.34E+02 1.41E+02 4.83E+02 2.65E+03 NO DATA , 5.14E+04 TE-129m 6.01E+0'i 2.24E+07 9.52E+06 2.07E+07 2.51E+08 NO DATA 3.03E+08 TE-129 2.82E-10 1.06E-10 6.86E-11 2.16E-10 1.18E-09 NO DATA 2.12E-10 1 TE-131m 3.60EM 5 1.76EM5 1.47E+05 2.79E+05 1.78E+06 NO DATA 1.75E+07 TE-131 3.68E-33 1.54E-33 1.16E-33 3.03E-33 1.61E-32 NO DATA 5.22E-34 TE-132 2.41E+06 1.56E+06 1.46E+06 1.72E+06 1.50E+07 NO DATA 7. 36EM7 I-130 4.16E+05 1.23E+06 4.84E+05 1.04E+08 1.91E+06 NO DATA 1.06EM6 I-131 2.97EM8 4. 24EM8 2.43E+08 1.39E+11 7.27E+08 NO DATA 1.12EM8 1 1-132 1.65E-01 4.40E-01 1.54E-01 1.54E+01 7.02E-01 NO DATA 8.27E-02 I-133 3.86E+06 6.72E+06 2.05E+06 9.87EM8 1.17E+07 NO DATA 6.04E+06 I-134 1.89E-12 5.13E-12 1.83E-12 8.88E-11 8.15E-12 NO DATA 4.47E-15 CLINTON-I 3-83 Rev.5-2/89 u- _ - _ - - ---
CPS-ODCM TABLE 3.5-20 (continued)- C COW MILK PATHWAY FACTORS - Raij ( ADM) 1 (m2 mrem /yr per yCi/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE I-135 1.29E+04 3.39E+04 1.25E+04 2.23E@6 5.43E+04 NO DATA 3.83E+04 CS-134 5.67E+09 1.35E+10 1.10E+10 NO DATA 4.37E+09 1.45E+09 2.36E+08 CS-136 2.64E+08 1.04EM9 7.49E+08 NO DATA 5.79EM8 7.94E+07 1.18E+08 CS-137 7.39E+09 1.01E+10 6.62E+09 NO DATA 3.43E+09 1.14E+09 1.96E+08 CS-138 8.69E-24 1.72E-23 8.50E-24 NO DATA 1.26E-23 1.24E-24 7.32E-29 BA-139 4.43E-08 3.16E-11 1.30E-09 NO DATA 2.95E-11 1.79E-11 7.86E-08 BA-140 2.72E+07 3.42E+04 1.78E-06 NO DATA 1.16E+04 1.96E+04 5.60E+07 BA-141 4.33E-46 3.27E-49 1.46E-47 NO DATA 3.04E-49 1.86E-49 2.04E-55 BA-142 2.51E-80 2.58E-83 1.58E-81 NO DATA 2.18E-83 1.46E-83 3.54E-98 LA-140 4.53E+00 2.28E+00 6.03E-01 NO DATA NO DATA NO DATA 1.67E+05 LA-142 1.89E-11 8.61E-12 2.15E-12 NO DATA NO DATA NO DATA 6.29E-08 CE-141 4.84E+03 3.27E+03 3.71E+02 NO DATA 1.52E+03 NO DATA 1.25E+07 CE-143 4.16E+01 3.07E+04 3.40E+00 NO DATA 1.35E%1 NO DATA 1.15E+06 CE-144 3.58E+05 1.50E+05 1.92E+04 NO DATA 8.87E+04 NO DATA 1.21E+08 PR-143 1.58E+02 6.35E+01 7.84E+00 NO DATA 3.66E+01 NO DATA 6.93E+05 PR-144 6.47E-54 2.69E-54 3.29E-55 NO DATA 1.52E-54 NO DATA 9.31E-61 ND-147 9.44E+01 1.09E+02 6.53E+00 NO DATA 6.38E+01 NO DATA , 5.24E+05 W-187 6.50E+03 5.43E+03 1.90E+03 NO DATA NO DATA NO DATA 1.78E406 NP-239 3.67E+00 3.60E-01 1.99E-01 NO DATA 1.12E+00 NO DATA 7.39E+04
- mrem /yr per y C1/m3 6
** 2.46 x 10 O
CLINTON-I 3-84 Rev.5-2/89
CPS-0DCM TABLE 3.5-21
/]
U GOAT MILK PATHNAY FACTORS - RC (INFANT) (m2 mrem /yr per pCi/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE H-3 NO DATA 4.86E+03* 4.86E+03* 4.86E+03* 4.86E+03* 4.86E+03* 4.86E+03* C-14 3.23E+06* 6.89E+05* 6.89E+05* 6.89E+05* 6.89E+05* 6.89E+05* 6.89E+05* NA-24 1.87E+06** 1.87E+06 1.87E+06 1.87E+06 1.87E+06 1.87E+06 1.87E+06 P-32 1.90E+11 1.12E+10 7.46E+09 NO DATA NO DATA NO DATA 2.58E+09 CR-51 NO DATA NO DATA 1.93E+04 1.26E+04 2.75E+03 2.45E+04 5.63E+05 MN-54 NO DATA 4.68E+06 1.06E+06 NO DATA 1.04E+06 NO DATA 1.72E+06 MN-56 NO DATA 3.75E-03 6.46E-04 NO DATA 3.22E-03 NO DATA 3.40E-01 FE-55 1.75E+06 1.13E+06 3.02E+05 NO DATA NO DATA 5.53E+05 1.44E+05 FE-59 2.91E+06 5.08E+06 2.00E+06 NO DATA NO DATA 1.50E+06 2.43E+06 CO-58 NO DATA 2.90E+06 7.24E+06 NO DATA NO DATA NO DATA 7.23E+06 CO-60 NO DATA 1.06E+07 2.49E+07 NO DATA NO DATA NO DATA 2.51E+07 () NI-63 4.19E+09 2.59E+08 1.45E+08 NO DATA NO DATA NO DATA 1.29E+07 NI-65 4.20E-01 4.76E-02 2.16E-02 NO DATA NO DATA NO DATA 3.62E+00 CU-64 NO DATA 2.04E+04 9.45E+03 NO DATA 3.45E+04 NO DATA 4.19E+05 , ZN-65 6.64E+08 2.28E+09 1.05E+09 NO DATA 1.10E+09 NO DATA 1.92E+09 ZN-69 2.32E-12 4.18E-12 3.11E-13 NO DATA 1.74E-12 NO DATA 3.41E-10 BR-83 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA i BR-84 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA ' NO DATA { BR-85 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA RB-86 NO DATA 2.65E+09 1.31E+09 NO DATA NO DATA NO DATA 6.79E+07 RB-88 NO DATA 2.25E-45 1.23E-45 NO DATA NO DATA NO DATA 2.19E-45 RB-89 NO DATA 4.09E-53 2.82E-53 NO DATA NO DATA NO DATA 1.39E-53 SR-89 2.64E+10 NO DATA 7.56E+08 NO DATA NO DATA NO DATA 5.42E+08 SR-90 2.55E+11 NO DATA 6.50E+10 PG DATA NO DATA NO DATA 3.19E+09 SR-91 5.65E+05 NO DATA 2.05E+04 NO DATA NO DATA NO DATA 6.69E+05 SR-92 9.83E+00 NO DATA 3.65E-01 NO DATA NO DATA NO DATA 1.06E+02
,e g Y-90 8.19E+01 NO DATA 2.19E+00 NO DATA NO DATA NO DATA 1.13E+05 V
l CLINTON-I 3-85 Rev.5-2/89 1 l l \
CPS-0DCM 1 TABLE 3.5-21 (continued) i GOAT MILK PATHWAY FACTORS - R (INFANT) (m2 mrem /yr per yCi/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG CI-LLI q ISOTOPE Y-91m 7.29E-20 NO DATA 2.48E-21 NO DATA NO DATA NO DATA 2.43E-16 Y-91 8.78E+03 NO DATA 2.34E+02 NO DATA NO DATA NO DATA 6.29E+05 Y-92 6.40E-05 NO DATA 1.80E-06 NO DATA NO DATA NO DATA 1.22E+00 Y-93 2.55E-01 NO DATA 6.95E-03 NO DATA NO DATA NO DATA 2.02E+03 ZR-95 8.16E+02 1.99E+02 1.41E+02 NO DATA 2.14E+02 NO DATA 9.90E+04 ZR-97 4.85E-01 8.33E-02 3,90E-02 NO DATA 8.40E-02 NO DATA 5.31E+03 NB-95 7.12E+04 2.93E+04 1.69E+04 NO DATA 2.10E+04 NO DATA 2.47E+07 M0-99 NO DATA 2.48E+07 4.84E+06 NO DATA 3.71E+07 NO DATA 8.18E+06 TC-99m 3.26E+00 6.73E+00 8.67E+01 NO DATA 7.24E+01 3.52E+00 1.96E+03 TC-101 3.26E-60 4.11E-60 4.06E-59 NO DATA 4.88E-59 2.24E-60 6.98E-58 RU-103 1.04E+03 NO DATA 3.47E+02 NO DATA 2.16E+03 NO DATA 1.26E+04 ( RU-105 9.60E-04 NO DATA 3.23E-04 NO DATA 7.06E-03 NO DATA 3.82E-01 RU-106 2.28E+04 NO DATA 2.84E+03 NO DATA 2.69E+04 NO DATA 1.73E%5 AG-110m 4.62E+07 3.37E+07 2.23E+07 NO DATA 4.83E+07 NO DATA 1.75E+09 : TE-125m 1.80E407 6.02E+06 2.43E+06 6.06EM 6 NO DATA NO DATA 8.58E+06 TE-127m 5.04E+07 1.67E+07 6.10E+06 1.46E+07 1.24EM8 NO DATA 2.03E+07 TE-127 7.57E+02 2.54E+02 1.63E+02 6.16E+02 1.85E+03 NO DATA , 1.59E+04 TE-129m 6.68E+07 2.29E+07 1.03E+07 2.57E+07 1.67ER8 NO DATA 3.99E+07 TE-129 3.25E-10 1.12E-10 7.59E-11 2.73E-10 8.10E-10 NO DATA 2.60E-08 TE-131m 4.04E+05 1.63E+05 1.34E+05 3.30E+05 1.12E+06 NO DATA 2.74E+06 TE-131 4.19E-33 1.55E-33 1.18E-33 3.74E-33 1.07E-32 NO DATA 1.69E-31 TE-132 2.54E+06 1.26EM6 1.17E+06 1.85E+06 7.86E+06 NO DATA 4.65E+06 I-130 4.22E+06 9.28E+06 3.73E+06 1.04E+09 1.02E+07 NO DATA 1.99E+06 I-131 3.25E+09 3.83E+09 1.69E+09 1.26E+12 4.48E+09 NO DATA 1.37EM8 I-132 1.73E+00 3.50E+00 1.25E+00 1.64E+02 3.91EM0 NO DATA 2.84E+00 I-133 4.34E+07 6.32E+07 1.85E+07 1.15E+10 7.43E+07 NO DATA 1.07E+07 I p I-134 1.97E-11 4.04E-11 1.44E-11 9.42E-10 4.52E-11 NO DATA 4.18E-11 l V ( l l CLINTON-I 3-86 Rev.5-2/89 i __ _ _ _ _ _ _ _ _ . _ _ _ _ _ _ _ _ _ _ J
l CPS-0DCM j 1 TABLE 3.5-21 (continued) C,, GOAT MILK PATHWAY FACTORS - R (INFANT) (m2 mrem /yr per pCi/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ! ISOTOPE l I-135 1.36E+05 2.70EM5 9.85E+04 2.42E+07 3.01E+05 NO DATA 9.77E+04 CS-134 1.09E+11 2.04E+11 2.06E+10 NO DATA 5.25E+10 2.15E+10 5.54E+08 CS-136 5.92E+09 1.74E+10 6.50E+09 NO DATA 6.94E+09 1.42E+09 2.64EM 8 CS-137 1.54E+11 1.80E+11 1.28E+10 NO DATA 4.84E+10 1.96E+10 5.63ER 8 CS-138 2.42E-22 3.93E-22 1.90E-22 NO DATA 1.96E-22 3.06E-23 6.28E-22 BA-139 5.14E-08 3.41E-11 1.49E-09 NO DATA 2.05E-11 2.07E-11 3.26E-06 BA-140 2.87E+07 2.87E+04 1.48E+06 NO DATA 6.82E+03 1.76E+04 7.06E+06 BA-141 4.97E-46 3.40E-49 1.57E-47 NO DATA 2.05E-49 2.07E-49 6.078-45 BA-142 2.76E-80 2.30E-83 1.36E-81 NO DATA 1.32E-83 1.39E-83 1.14E-79 i LA-140 4.83E+00 1.91E+00 4.90E-01 NO DATA NO DATA NO DATA 2.24EM4 LA-142 2.07E-11 7.60E-12 1.82E-12 NO DATA NO DATA NO DATA 1.29E-06 CE-141 5.20E+03 3.17E+03 3.73E+02 NO DATA 9.78E+02 NO DATA 1.64E+06 I CE-143 4.75EM1 3.15E+04 3.60E+00 NO DATA 9.18EM0 NO DATA 1.84EM5 CE-144 2.79E+05 1.14E+05 1.56E+04 NO DATA 4.61E+04 NO DATA 1.60E+07 PR-143 1.78E+02 6.66E+01 8.83E+00 NO DATA 2.47E+01 NO DATA 9.40E+04 PR-144 7.51E-54 2.90E-54 3.78E-55 NO DATA 1.05E-54 NO DATA 1.35E-49 ND-147 1.06E+02 1.08E+02 6.65E+00 NO DATA 4.18E+01 NO DATA 6.88E+04 W-187 7.27EM3 5.06E+03 1.75E+03 NO DATA NO DATA NO DATA ' 2.97EM5 NP-239 4.37E%0 3.91E-01 2.21E-01 NO DATA 7.80E-01 NO DATA 1.13EM4
- mrem /yr per p Ci/m3 0
** 1.87 x 10 Q
L) CLINTON-I 3-87 Rev.5-2/89 l l l l
-- - - - - - - - - I
CPS-ODCM TABLE 3.5-22 es , () GOAT MILK PATHWAY FACTORS - R (CHILD) i (ma mrem /yr per pCi/sec) i j ORGAN: BONE LIVER T. BODY THYROID
~ ~ KIDNEY LUNG GI-LLI-ISOTOPE {
H-3 NO DATA 3.20E+03* 3.20E+03* 3.20E+03* 3.20E+03* 3.20E+03* 3.20E+03* C-14 1.65E+06* 3.29E+05* 3.29E+05* 3.29E+05* 3.29E+05* 3.29E+05* 3.29E+05* NA-24 1.07E+06** 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 i l P-32 9.32E+10 4.36E+09 3.59E+09 NO DATA NO DATA NO DATA 2.58E+09 CR-51 NO DATA NO DATA 1.22E+04 6.77E+03 1.85E+03 1.24E+04 6.47E+05 MN-54 NO DATA 2.51E+06 6.70E+05 NO DATA 7.05E+05 NO DATA 2.11E+06 MN-56 NO DATA 1.53E-03 3.45E-04 NO DATA 1.85E-03 NO DATA 2.21E-01 FE-55 1.45E+06 7.65E+05 2.38E+05 NO DATA NO DATA 4.35E+05 1.42E+05 l FE-59 1.55E+06 2.52E+06 1.25E+06 NO DATA NO DATA 7.29E+05 2.62E+06 CO-58 NO DATA 1.46E+06 4.46E+06 NO DATA NO DATA NO DATA 8.49E+06 i CD-60 NO DATA 5.16E+06 1.52E+07 NO DATA NO DATA NO DATA 2.86E+07
/~N NI-63 3.55E+09 1.90E+08 1.21E+08 NO DATA NO DATA NO DATA 1.28E+07 .
Q_,l ' NI-65 1.99E-01 1.87E-02 1.09E-02 NO DATA NO DATA NO DATA 2. 29E400 CU-64 NO DATA 8.23E+03 4.97E+03 NO DATA 1.99E+04 NO DATA 3.86E+05 ZN-65 4.96E+08 1.32E+09 8.22E+08 NO DATA 8.3?E+08 NO DATA 2.32E+08 ZN-69 1.09E-12 1.58E-12 1.46E-13 NO DATA 9.56E-13 NO DATA 9.94E-11 BR-83 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA BR-84 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA ' NO DATA i BR-85 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA RB-86 NO DATA 1.05E+09 6.47E+08 NO DATA NO DATA NO DATA 6.77E+07 RB-88 NO DATA 8.59E-46 5.97E-46 NO DATA NO DATA NO DATA 4.21E-47 RB-89 NO DATA 1.67E-53 1.49E-53 NO DATA NO DATA NO DATA 1.46E-55 SR-89 1.39E+10 NO DATA 3.96E+08 NO DATA NO DATA NO DATA 5.37E+08 SR-90 2.35E+11 NO DATA 5.95E+10 NO DATA NO DATA NO DATA 3.16E+09 SR-91 2.71E+05 NO DATA 1.02E+04 NO DATA NO DATA NO DATA 5.99E+05 i SR-92 4.61E+00 NO DATA 1.85E-01 NO DATA NO DATA NO DATA 8.74E+01 { Y-90 3.86E+01 NO DATA 1.03E+00 NO DATA NO DATA NO DATA 1.10E+05 () l l CLINTON-I 3-88 Rev.5-2/89
~
CPS-0DCM J t N , TABLE 3.5-22-(continued) ,
- D C U GOAT MILK PATHWAY FACTORS - R,1)(CH M )
(m2 mrem /yr per pCi/sec) q ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE 1 Y-91m 3.44E-20 NO DATA 1.25E-21 NO DATA NO DATA NO DATA 6.73E-17 Y-91 4.67E+03 NO DATA 1.25E+02 NO DATA NO DATA NO DATA 6.22E+05 Y-92 3.02E-05 NO DATA 8.64E-07 NO DATA NO DATA NO DATA 8.73E-01 , 1 Y-93 1.20E-01 NO DATA 3.29E-03 NO DATA NO DATA NO DATA 1.79E+03 ; ZR-95 4.58E+02 1.01E+02 8.97E+01 NO DATA 1.44E+02 NO DATA 1.05E+05 ! ZR-97 2.29E-01 3.31E-02 1.95E-02 NO DATA 4.76E-02 NO DATA 5.02E+03 i NB-95 3.81E+04 1.48E+04 1.06E+04 NO DATA 1.39E+04 NO DATA 2.75E+07 MO-99 NO DATA- 9.74E+06 2.41E+06 NO DATA 2.08E+07 NO DATA 8.05E+06 TC-99m 1.58EMO 3.10E+00 5.13E+01 NO DATA 4.50E+01 1.57EM0 1.76E+03 i TC-101 1.54E-60 1.61E-60 2.04E-59 NO DATA 2.74E-59 8.50E-61 5.11E-60
. RU-103 5.10E+02 NO DATA 1.96E+02 NO DATA 1.28E+03 NO DATA 1.32E+04 RU-105 4.53E-04 NO DATA 1.65E-04 NO DATA 3.99E-03 NO DATA 2.96E-01 RU-106 1.11E+04 NO DATA 1.38E+03 NO DATA 1.49E+04 NO DATA 1.72E+05 AG-110m 2.50E+07 1.69E+07 1.35E+07 NO DATA 3.15E+07 NO DATA 2.01E+09 TE-125m 8.84EM 6 2.39E+06 1.18E+06 2.48E+06 NO DATA NO DATA 8.53E+06 TE-127m 2.49E+07 6.71EM6 2.96E+06 5.96E+06 7.10E+07 NO DATA 2.02E+07 TE-127 3.57E+02 9.61EMI 7.65E+01 2.47E+02 1.01E+03 NO DATA '
1.39E+04 TE-129m 3.24E+07 9.06EM6 5.03EM6 1.05E+07 9.52EM7 NO DATA 3.96E+07 i TE-129 1.53E-10 4.28E-11 3.64E-11 1.09E-10 4.49E-10 NO DATA 9.55E-09 TE-131m 1.91E+05 6.60E+04 7.02E+04 1.36E+05 6.39E+0.i NO DATA 2.68E+06 TE-131 1.96E-33 5.9/E-34 5.83E-34 1.50E-33 5.92E-33 NO DATA 1.03E-32 TE-132 1.23E+06 5.45E+05 6.59E+05 7.94E+05 5.06E+06 NO DATA 5.49E+06 I-130 2.06E+06 4.17E+06 2.15E+06 4.59E+08 6.23E+06 NO DATA 1.95E+06 I-131 1.56E+09 1.57E+09 8.94E+08 5.20E+11 2.58E+09 NO DATA 1.40E M8 , I-132 8.32E-01 1.52E+00 7.03E-01 7.09EMI 2.34E+00 NO DATA 1.80E+00 1-133 2.06E+07 2.55E+07 9.64E+06 4.73E+09 4.25E+07 NO DATA 1.03E+07 I -134 9.51E-12 1.77E-11 8.13E-12 4.06E-10 2.70E-11 NO DATA 1.17E-11 O CLINTON-I 3-89 Rev.5-2/89 l
1 CPS-ODCM TABLE 3.5-22 (continued) A C I' (,/ GOAT MILK PATHWAY FACTORS - Raij (CHM) (me mrem /yr per pCi/sec) l ORGAN: BON _E LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE I-135 6.53E+04 1.17E@5 5.56E+04 1.04E+07 1.80E+05 NO DATA 8.95EM4 CS-134 6.76E+10 1.11E+11 2.34E+10 NO DATA 3.44E+10 1.23E+10 5.98E+08 i CS-136 3.03E+09 8.33E+09 5.39E+09 NO DATA 4.44E+09 6.62E+08 2.93E+08 l CS-137 9.65E+10 9.23E+10 1.36E+10 NO DATA 3.01E+10 1.08E+10 5.78E+08 CS-138 1.15E-22 1.59E-22 1.10E-22 NO DATA 1.12E-22 1.21E-23 7.34E-23 BA-139 2.42E-08 1.29E-11 7.01E-10 NO DATA 1.13E-11 7.59E-12 1.40E-06 BA-140 1.40E+07 1.22E+04 8.15E+05 NO DATA 3.98E+03 7.29E+03 7.07E+06 BA-141 2,34E-46 1.31E-49 7.62E-48 NO DATA 1.13E-49 7.70E-49 1.33E-46 BA-142 1.31E-80 9.44E-84 7.32E-82 NO DATA 7.64E-84 5.55E-84 1.71E-82 LA-140 2.32E+00 8.12E-01 2.53E-01 NO DATA NO DATA NO DATA 2.26E+04 LA-142 9.85E-12 3.14E-12 9.83E-13 NO DATA NO DATA NO DATA 6.22E-07 [_ CE-141 5.93E+03 1.31E+03 1.94E+02 NO DATA 5.73E+02 NO DATA 1.63E+06 CE-143 2.24E+01 1.22E+04 1.76E+00 NO DATA 5.10E+00 NO DATA 1.78E+05 CE-144 1.94E+05 6.10E+04 1.04E+04 NO DATA 3.38E+04 NO DATA 1.59E+07 l PR-143 8.61E+01 2.58E+01 4.27E+00 NO DATA 1.40E+01 NO DATA 9.29EM4 PR-144 3.53E-54 1.09E-54 1.78E-55 NO DATA 5.78E-55 NO DATA 2.35E-51 ND-147 5.33E+01 4.32E+01 3.34E+00 NO DATA 2.37E+01 NO DATA ' 6.84E+04 W-187 3.46E+03 2.05E+03 9.20E+02 NO DATA NO DATA NO DATA 2.88E+05 NP-239 2.07EMO 1.49E-01 1.04E-01 NO DATA 4.29E-01 NO DATA 1.10E+04 )
)
l
- mrem /yr per uCi/m3 6
** 1.07 x 10 1
(O .) l CLINTON-I 3-90 Rev.5-2/89 i
- - - - - _ - _ - _ _ _ - . _ _ _ . - _ _ _ . _ - _ _ - - _ - _ _ - . . _ _ J
CPS-0DCM l TABLE 3.5-23 n C (,/ GOAT MILK PATHWAY FACTORS - R (TEEN) (m2 mrem /yr per yCi/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE H-3 NO DATA 2.02E+03* 2.02E+03* 2.02E+03* 2.02E+03* 2.02E+03* 2.02+03* C-14 6.70E+05* 1.34E+05* 1.34E+05* 1.34E+05* 1.34E+05* 1.34E+05* 1.34E+05* NA-24 5.15E+05** 5.15E+05 5.15E+05 5.15E+05 5.15E+05 5.15E+05 5.15E+05 P-32 3.78E+10 2.34E+09 1.47E+09 NO DATA NO DATA NO DATA 3.18E+09 CR-51 NO DATA NO DATA 5.94E+03 3 30E+03 1.30E+03 8.48E+03 9.98E+05 MN-54 NO DATA 1.68E+06 3.32E+05 NO DATA 5.00E+05 NO DATA 3.44E+06 MN-56 NO DATA 8.77E-04 1.56E-04 NO DATA 1.11E-03 NO DATA 5.77E-02 FE-55 5.79E+05 4.11E+05 9.57E+04 NO DATA NO DATA 2.60E+05 1.78E+05 FE-59 6.75E+05 1.58E406 6.08E+05 NO DATA NO DATA 4.97E+05 3.73E+06 C0-58 NO DATA 9.51E+05 2.19E+06 NO DATA NO DATA NO DATA 1.31E+07 ; CO-60 NO DATA 3.32E+06 7.47E+06 NO DATA NO DATA NO DATA 4.32E+07
/ NI-63 1.42E+09 4.81E+07 NO DATA NO DATA NO DATA 1.60E+07 4
1.00E+08 (m / , 1 NI-65 8.09E-02 1.03E-02 4.71E-03 NO DATA NO DATA NO DATA 5.61E-01 CU-64 NO DATA 4.68E+03 2.20E+03 NO DATA 1.18E+04 NO DATA 3.63E+05 ZN-65 2.52E+08 8.76E+08 4.09E+08 NO DATA 5.61E+08 NO DATA 3.71E+08 1 I ZN-69 4.44E-13 8.46E-13 5.92E-14 NO DATA 5.53E-13 NO DATA 1.56E-12 BR-83 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA , NO DATA ER-84 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA BR-85 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA RB-86 NO DATA 5.66E+08 2.66E+08 NO DATA NO DATA NO DATA 8.38E+07 RB-88 NO DATA 4.66E-46 2.48E-46 NO DATA NO DATA NO DATA 3.99E-53 l RB-89 NO DATA 9.52E-54 6.73E-54 NO DATA NO DATA NO DATA 1.46E-62 l SR-89 5. 59E409 NO DATA 1.60E+08 NO DATA NO DATA NO DATA 6. 65E408 SR-90 1.38E+11 NO DATA 3.40E+10 NO DATA NO DATA NO DATA 3.87E+09 i SR-91 1.11E+05 NO DATA 4.40E+03 NO DATA N0 n ATA NO DATA 5.01E+05 SR-92 1.89E+00 NO DATA 8.05E-02 NO DATA NO DATA NO DATA 4.81E+01 f-~s Y-90 1.56E+01 NO DATA 4.21E-01 NO DATA NO DATA NO DATA 1.29E+05 b CLINTON-1 3-91 Rev.5-2/89 _ _ _ _ _ _ _ _ _ _ _ _ _ _ - . . - - . __ l
TABLE 3.5-23 (continued) C GOAT MILK PATINAY FACTORS - R (TEEN) (m2 mrem /yr pery Ci/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE Y-91m 1.41E-20 NO DATA 5.37E-22 NO DATA NO DATA NO DATA 6.64E-19 Y-91 1.89E+03 NO DATA 5.07E+01 NO DATA NO DATA NO DATA 7.75E+05 Y-92 1.23E-05 NO DATA 3.57E-07 NO DATA NO DATA NO DATA 3.39E-01 Y-93 4.86E-02 NO DATA 1.33E-03 NO DATA NO DATA NO DATA 1.49E+03 ZR-95 1.98E+02 6.24EM I 4.29E+01 NO DATA 9.17E+01 NO DATA 1.44EM5 ZR-97 9.43E-02 1.87E-02 8.60E-03 NO DATA 2.83E-02 NO DATA 5.05E+03 NB-95 1.69EM4 9.37E+03 5.16E+03 NO DATA 9.08E+03 NO DATA 4.01E+07 MO-99 NO DATA 5.33E+06 1.02E+06 NO DATA 1.22E+07 NO DATA 9.55E+06 TC-99m 6.87E-01 1.92E+00 2.48E+01 NO DATA 2.86E+01 1.06E+00 1.26E+03 TC-101 6.26E-61 8.91E-61 8.75E-60 NO DATA 1.61E-59 5.43E-61 1.52E-67 RU-103 2.17E+02 NO DATA 9.27E+01 NO DATA 7.64E+02 NO DATA 1.81E+04 RU-105 1.86E-04 NO DATA 7.21E-05 NO DATA 2.35E-03 NO DATA 1.50E-01 RU-106 4.47E+03 NO DATA 5.63E+02 NO DATA 8.62E+03 NO DATA 2.14E+05 AG-110m 1.15E+07 1.09E+07 6.62E+06 NO DATA 2.08E+07 NO DATA 3.06E+09 TE-125m 3.59E+06 1.29E+06 4.80E+05 1.00E+06 NO DATA NO DATA 1.06E+07 TE-127m 1.01E+07 3.57E+06 1.20E+06 2.39E+06 4.08E+07 NO DATA 2. 51EM7 TE-127 1.48E+02 5.14E+01 3.18E+01 1.02E+02 5.87E+02 NO DATA , 1.14EM4 TE-129m 1.32E+07 4.89E+06 2.08E+06 4.25E+06 5.51E+07 NO DATA 4.94E+07 TE-129 6.22E-11 2.32E-11 1.51E-11 4.44E-11 2.61E-10 NO DATA 3.40E-10 TE-131m 7.86E+04 3.77E+04 3.14E+04 5.67E+04 3.93E+05 NO DATA 3.02E+06 TE-131 8.04E-34 3.31E-34 2.51E-34 6.19E-34 3.51E-33 NO DATA 6.60E-35 TE-132 5.13E+05 3.25E+05 3.06E+05 3.43E+05 3.12E+06 NO DATA 1.03E+07 I-130 8.82E+05 2.55E+06 1.02E+06 2.08E+08 3.93E+06 NO DATA 1.96E+06 I-13' 6.44E+08 9.01E+08 4.84E+08 2.63E+11 1.55E+09 NO DATA 1.78E+08 I-132 3.52E-01 9.20E-01 3.30E-01 3.10E+01 1.45E+00 NO DATA 4.01E-01 I-133 8.48E+06 1.44E+07 4.39E+06 2.01E+09 2.52E+07 NO DATA 1.09E+07 I-134 4.03E-12 1.07E-11 3.84E-12 1.78E-10 1.68E-11 NO DATA 1.41E-13 CLINTON-I 3-92 Rev.5-2/89
~
CPS-ODCM l TABLE 3.5-23 (continued) l [ C0AT MILK PATHWAY FACTORS - R (TEEN) (m2 mrem /yr per ECi/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI I ISOTOPE I-135 2.75E+04 7.08E+04 2.62E+04 4.56E+06 1.12E+05 NO DATA 7.85E+04 CS-134 2.94E+10 6.91E+10 3.21E+10 NO DATA 2.20E+10 8.39E+09 8.60E+08 CS-136 1.34E+09 5.27E+09 3.54E+09 NO DATA 2.87E+09 4.52E+08 4.24E+08 CS-137 4.01E+10 5.33E+10 1.86E+10 NO DATA 1.82E+10 7.05EM9 7.59EM8 CS-138 4.73E-23 9.08E-23 4.54E-23 NO DATA 6.70E-23 7.80E-24 4.12E-26 BA-139 9.84E-09 6.92E-12 2.87E-10 NO DATA 6.53E-12 4.77E-12 8.78E-08 I BA-140 5.82E+06 7.13E+03 3.75E+05 NO DATA 2.42E+03 4.80E+03 8.98E+06 BA-141 9.53E-47 7.11E-50 3.18E-48 NO DATA 6.60E-50 4.87E-50 2.03E-52 BA-142 5.44E-81 5.44E-84 3.35E-82 NO DATA 4.60E-84 3.62E-84 1.67E-92 l LA-140 9.67E-01 4.75E-01 1.26E-01 NO DATA NO DATA NO DATA 2.73E+04 LA-142 4.08E-12 1.81E-12 4.51E-13 NO DATA NO DATA NO DATA 5.52E-08 O CE-141 1.07E+03 7.12E+02 8.17E+01 NO DATA 3.35E+02 NO DATA 2.04E+06 V ! CE-143 9.14E+00 6.65E+03 7.43E-01 NO DATA 2.98E+00 NO DATA 2.00E+05 CE-144 7.86E+04 3.2SE+04 4.23E+03 NO DATA 1.94E+04 NO DATA 1.98E+07 PR-143 3.47E+01 1.39E+01 1.73E400 NO DATA 8.06E+00 NO DATA 1.14E+05 PR-144 1.42E-54 5.81E-55 7.19E-56 NO DATA 3.33E-55 NO DATA 1.56E-57 ND-147 2.17E+01 2.36E+01 1.41E+00 NO DATA 1.38E+01 NO DATA ' 8.50E+04 W-187 1.43E403 1.16E+03 4.08E+02 NO DATA NO DATA NO DATA 3.15E+05 NP-239 8.38E-01 7.90E-02 4.39E-02 NO DATA 2.48E-01 NO DATA 1.27E+04
- mrem /yr per pCi/m3
** 5.15 x ) h 1
O l CLINTON-I 3-93 Rev.5-2/89 l
~
CPS-0DCM TABLE 3.5-24 h GOAT MILK PATHWAY FACTORS - R (ADULT) (ms mrem /yr per pCi/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI , ISOTOPE H-3 NO DATA 1.55E+03* 1.55E+03* 1.55E+03* 1.55E+03* 1.55E+03* 1.55E+03* C-14 3.63E+05* 7.26E+04* 7.26E+04* 7.26E+04* 7.26E+04* 7.26E+04* 7.26E+04* NA-24 2.95E+05** 2.95E+05 2.95E+05 2.95E+05 2.95E+05 2.95E+05 2.95E+05 P-32 2.05E+10 1.27E+09 7.91E+08 NO DATA NO DATA NO DATA 2.30EM9 CR-51 NO DATA NO DATA 3.43E+03 2.05E+03 7.56E+02 4.55E+03 8.63E+05 MN-54 NO DATA 1.01E+06 1.92E+05 NO DATA 2.99E+05 NO DATA 3.08E+06 MN-56 NO DATA 4.96E-04 8.79E-05 NO DATA 6.29E-04 NO DATA 1.58E-02 FE-55 3.27E+05 2.26E+05 5.27E+04 NO DATA NO DATA 1.26E+05 1.30E+05 FE-59 3.85E+05 9.06E+05 3.47E+05 NO DATA NO DATA 2.53E+05 3.02E+06 Co-58 NO D/.TA 5.62E+05 1.26E+06 NO DATA NO DATA NO DATA 1.14E+07 CO-60 NO DATA 1.96E+06 4.33E+06 NO DATA NO DATA NO DATA 3.69E+07 NI-63 8.05E+08 5.58EM7 2.70E+07 NO DATA NO DATA NO DATA 1.16E+07 NI-65 4.43E-02 5.76E-03 2.63E-03 NO DATA NO DATA NO DATA 1.46E-01 CU-64 NO DATA 2.62E+03 1.23E+03 NO DATA 6.62E+03 NO DATA 2.24E+05 ZN-65 1.64E+08 5.22E+08 2.36E+08 NO DATA 3.49E%8 NO DATA 3.29EM8 ZN-69 2.41E-13 4.61E-13 3.21E-14 NO DATA 3.00E-13 NO DATA 6.93E-14 BR-83 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA BR-84 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA ' NO DATA , i BR-85 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA RB-86 NO DATA 3.10E+08 1.45E+08 NO DATA NO DATA NO DATA 6.12EM7 RB-88 NO DATA 2.57E-46 1.36E-46 NO DATA NO DATA NO DATA 3.55E-57 l RB-89 NO DATA 5.37E-54 3.78E-54 NO DATA NO DATA NO DATA 3.12E-67 SR-89 3.04E+09 NO DATA 8.73E+07 NO DATA NO DATA NO DATA 4.88E+08 SR-90 9.78E+10 NO DATA 2.40E+10 NO DATA NO DATA NO DATA 2.83E+09 , i SR-91 6.01E+04 NO DATA 2.43E+03 NO DATA NO DATA NO DATA 2.86E+05 SR-92 1.03E+00 NO DATA 4.45E-02 NO DATA NO DATA NO DATA 2.04E+01 Y-90 8.48E+00 NO DATA 2.28E-01 NO DATA NO DATA NO DATA 9.00E+04 CLINTON-I 3-94 Rev.5-2/89 l
i CPS-0DCM l l TABLE 3.5-24 (continued) GOAT MILK PATHWAY FACTORS - RC (ADULT) (m2 mrem /yr per pCi/sec) i ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI f ISOTOPE Y-91m 7.69E-21 NO DATA 2.98E-22 NO DATA NO DATA NO DATA 2.ZbE-20 Y-91 1.03E+03 NO DATA 2.75E+01 NO DATA NO DATA NO DATA 5.66E+05 Y-92 6.68E-06 NO DATA 1.95E-07 NO DATA NO DATA NO DATA 1.17E-01 Y-93 2.65E-02 NO DATA 7.32E-04 NO DATA NO DATA NO DATA 8.41E+02 l ZR-95 1.13E+02 3.63E+01 2.46E+01 NO DATA 5.69E+01 NO DATA 1.15E+05 ZR-97 5.17E-02 1.04E-02 4.77E-03 NO DATA 1.58E-02 NO DATA 3.23E+03 l NB-95 9.90E+03 5.51E+03 2.96E+03 NO DATA 5.45E+03 NO DATA 3.34E+07 MO-99 NO DATA 2.96E+06 5.63E+05 NO DATA 6.71E+06 NO DATA 6.86E+06 TC-99m 3.95E-01 1.12E+00 1.42E+01 NO DATA 1.70EM1 5.47E-01 6.61E+02 2 TC-101 3.43E-61 4.94E-61 4.84E-60 NO DATA 8.89E-60 2.52E-61 1.48E-72 RU-103 1.22E+02 NO DATA 5.24E+01 NO DATA 4.64E+02 NO DATA 1.42E+04
, RU-105 1.02E-04 NO DATA 4.02E-05 NO DATA 1.32E-03 NO DATA 6.23E-02 RU-106 2.44E+03 NO DATA 3.09E+02 NO DATA 4.72E%3 NO DATA 1.58EM5 l AG-110m 6.96E+06 6.44E+06 3.82EM6 NO DATA 1.27E+07 F0 DATA 2.63E+09 l TE-125m 1.95E+06 7.07E+05 2.61E+05 5.87E+05 7.94E+06 NO DATA 7.79E+06 I TE-127m 5.46E+06 1.95EM 6 6.66E+05 1.40E+06 2.22E+07 NO DATA 1.83E%7 TE-127 7.82E+01 2.81E+01 1.69E+01 5.80E+01 3.19E+02 NO DATA 6.17E+03 TE-129m 7.21E+06 2.69EM6 1.14E+06 2.48E+06 3.01E+07 NO DATA 3.63E+07 TE-129 3.83E-11 1.27E-11 8.23E-12 2.59E-11 1.42E-10 NO DATA 2.55E-11 TE-131m 4.33E+04 2.12E+04 1.76E+04 3.35E+04 2.14E+05 NO DATA 2.10E+06 i TE-131 4.37E-34 1.83E-34 1.38E-34 3.60E-34 1.92E-33 NO DATA 6.19E-35 !
TE-132 2.87E+05 1.86E+05 1.74E+05 2.05E+05 1.79EM6 NO DATA 8.79E%6 I-130 5.00E+05 1.47E+06 5.82E+05 1.25E+08 2.30E+06 NO DATA 1.27E+06 I-131 3.54E+08 5.06E+08 2.90E+08 1.66E+11 8.68E+08 NO DATA 1.34E% 8 I-132 1.98E-01 5.29E-01 1.85E-01 1.85E+01 8.43E-01 NO DATA 9.93E-02 l I-133 4.62E+06 8.03E+06 2.45E+06 1.18E+09 1.40E+07 NO DATA 7.22E+06
- I-134 2.27E-12 6.16E-12 2.20E-12 1.07E-10 9.80E-12 NO DATA 5.37E-15 )
i CLINTON-I 3-95 Rev.5-2/89 l l l l
CPS-0DCM ! l
. TABLE 3.5-24 (continued) './~) C i V GOAT MILK PATHWAY FACTORS - R (ADULT) 'i l (m2 mrem /yr per pCi/sec)
ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE I I-135 .1. 55EM4 4.06E+04 1.50E+04 2.68E+06 6.51E+04 NO DATA 4.59E+04 CS-134- 1.69E+10 4.03E+10 3.29E+10 NO DATA 1.30E+10 4.32E+09 7.04E+08 CS-136 7.88E+08 3.11E+09 2.24E+09 NO DATA 1.73E+09 2.37E+08 3.53E+08 CS-137 2.21E+10 3.03E+10- 1.98E+10 NO DATA 1.02E+10 3.41E+09 5.84E+08 CS-138' 2.61E-23 5.15E-23 2.55E-23 NO DATA 3.78E-23 3.73E-24 2.20E-28 BA-139 5.32E-09 3.79E-12 1.56E-10 NO DATA 3.54E-12 2.15E-12 9.44E-09 BA-140 3.23E+06 4.05E+03 2.11E+05 NO DATA 1.38E+03 2.32E+03 6.65E+06 BA-141 5.18E-47 3.92E-50 1.75E-48 NO DATA 3.64E-50 2.22E-50 2.44E-56 BA-142 3.00E-81 3.09E-84 1.89E-82 NO DATA 2.61E-84 1.75E-84 4.23E-99 LA-140 5.40E-01 2.72E-01 7.19E-02 NO DATA NO DATA NO DATA 2.00E+04 LA-142 2.27E-12 1.03E-12 2.57E-13 NO DATA NO DATA NO DATA 7.52E-09 CE-141 5.80E+02 3.92E+02 4.45E+01 NO DATA 1.82E+02 NO DATA 1.50E+06 CE-143 5.00E+00 3.70E+03 4.09E-01 NO DATA 1.63E+00 NO DATA 1.38E+05 CE-144 4.29E+04 1.79E+04 2.30E+03 NO DATA 1.06E+04 NO DATA 1.45E+07 PR-143 1.89E+01 7.56E+00 9.35E-01 NO DATA 4.37E+00 NO DATA 8.26E+04 i I PR-144 7.71E-55 3.20E-55 3.92E-56 NO DATA 1.80E-55 NO DATA 1.11E-61 ND-147 1.13E+01 1.30E+01 7.79E-01 NO DATA 7.64E+00 NO DATA , 6.25E+04 W-187 7.78E+02 6.50E+02 2.27E+02 NO DATA NO DATA NO DATA 2.13E+05 l l NP-239 4.39E-01 4.32E-02 2.38E-02 NO DATA 1.35E-01 NO DATA 8.86E+03 1
- mrom/yr per yCi/m3 5
** 2.95 x 10 l
O i l CLINTON-I 3-96 Rev.5-2/89
CPS-0DC24 ; l TABLE 3.5-25 C) MEAT PATHWAY FACTORS - R (CHILD) (m2 mrem /yr per yCi/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY, LUNG GI-LLI ISOTOPE H-3 NO DATA 2.33E+02* 2.33E+02* 2.33E+02* 2.33E+02* 2.33E+02* 2.33E+02* C-14 5.29E+05* 1.06E+05* 1.06E+05* 1.06E+05* 1.06E+05* 1.06E+05 1.06E+05* NA-24 1.84E-03** 1.84E-03 1.84E-03 1.84E-03 1.84E-03 1.84E-03 1.84E-03 P-32 7.43E+09 3.47E+08 2.86E+08 NO DATA NO DATA NO DATA 2.05E+08 CR-51 NO DATA NO DATA 8.78E+03 4.88E+03 1.33E+03 8.90E+03 4.66E+05 MN-54 NO DATA 8.03E406 2.14E+06 NO DATA 2.25E+06 NO DATA 6.74E+06 MN-56 NO DATA 1.56E-53 3.52E-54 NO DATA 1.89E-53 NO DATA 2.26E-51 FE-55 4.58E+08 2.43E+08 7.52E+07 NO DATA NO DATA 1.37E+08 4.50E+07 FE-59 3.76E+08 6.09E+08 3.03E+08 NO DATA NO DATA 1.76E+08 6.34E+08 l C0-58 NO DATA 1.64E+07 5.03E+07 NO DATA NO DATA NO DATA 9.58E+07 CO-60 NO DATA 6.93E+07 2.04E+08 NO DATA NO DATA NO DATA 3.84E+08 () NI-63 2.91E+10 1.56E+09 9.90E+08 NO DATA NO DATA NO DATA 1.05E+08 NI-65 3.55E-52 3.34E-53 1.92E-53 NO DATA NO DATA NO DATA 4.10E-51 CU-64 NO DATA 2.77E-07 1.67E-07 NO DATA 6.69E-07 NO DATA 1.30E-05 ZN-65 3.75E+08 1.00E+09 6.22E+08 NO DATA 6.30E+08 NO DATA 1.76E+08 ZN-69 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00E+00 NO DATA 0.00E+00 BR-83 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA , NO DATA BR-84 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA BR-85 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA RB-86 NO DATA 5.76E+08 3.54E+08 NO DATA NO DATA NO DATA 3.71E+07 RB-88 NO DATA 0.00E+00 0.00E+00 NO DATA NO DATA NO DATA 0.00E+00 RB-89 NO DATA 0.00E+00 0.00E+00 NO DATA NO DATA NO DATA 0.00E+00 SR-89 4.80E+08 NO DATA 1.37E+07 NO DATA NO DATA NO DATA 1.86E407 SR-90 1.04E+10 NO DATA 2.64E+09 NO DATA NO DATA NO DATA 1.40E+08 SR-91 2.26E-10 NO DATA 8.53E-12 NO DATA NO DATA NO DATA 4.99E-10 SR-92 2.00E-49 NO DATA 8.04E-51 NO DATA NO DATA NO DATA 3.80E-48 Y-90 1.73E+02 NO DATA 4.62E+00 NO DATA NO DATA NO DATA 4.91E+05 j
) )
CLINTON-I 3-97 Rev.5-2/89 j
CPS-0DCN _ . TABLE 3.5-25 (continued) - MEAT PATHWAY FACTORS - R (CHILD) (m2 mrem /yr per pCi/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI . ISOTOPE- j Y-91m 0.00E+00 NO DATA 0.00E+00 NO DATA NO DATA NO DATA 0.00E+00 Y-91 1.80E+06 NO DATA 4.81E+04 NO DATA NO DATA NO DATA 2.40E+08 Y-92 2.37E-39 NO DATA 6.78E-41 NO DATA NO DATA NO DATA 6.84E-35 Y-93 6.98E-12 NO DATA 1.92E-13 NO DATA NO DATA NO DATA 1.04E-07 ZR-95 2.67E+06 5.87E+05 5.22E+05 NO DATA- 8.402+05 NO DATA 6.12E+08 ZR-97 3.16E-05 4.57E-06 2.69E-06 NO DATA 6.55E-06 NO DATA 6.92E-01 1 NB-95 3.10E+06 1.21E+06 8.61E+05 NO DATA 1.13E+06 NO DATA 2.23E+09 MO-99 NO DATA 1.14E+05 2.83E+04 NO DATA 2.44E+05 NO DATA 9.45E+04 i
'TC-99m 6.01E-21 1.18E-20 1.95E-19 NO DATA 1.71E-19 5.98E-21 6.71E-18 1 TC-101 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00E+00 0.00E+00 0.00E+00 ,
RU-103 1.55E+08 NO DATA 5.96E+07 NO DATA 3.90E+08 NO DATA 4.01E+09 O O RU-105 8.48E-28 NO DATA 3.08E-28 NO DATA 7.45E-27 NO DATA 5.54E-25 i i RU-106 4.43E+09 NO DATA 5.53E+08 NO DATA 5.99E+09 NO DATA 6.90E+10 AG-110m 8.41E+06 5.68E+06 4.54E+06 NO DATA 1.06E+07 NO DATA 6.75E+08 TE-125m 5.69E+08 1.54E+08 7.58E+07 1.60E+08 NO DATA NO DATA 5.49E+08' TE-127m 1.77E+09 4.78EM8 2.11E+08 4.24E+08 5.06E+09 NO DATA 1.44E+09 TE-127 3.34E-10 9.01E-11 7.17E-11 2.31E-10 9.51E-10 NO DATA , 1.31E-08 TE-129m 1.79E+09 4. 99E-K)8 2.77E+08 5.76E+08 5.25E+09 NO DATA 2.18E%9 TE-129 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00EMO NO DATA 0.00E+00 TE-131m 6.97E+02 2.41EM 2 2.57E+02 4.96E+02 2.33E+03 NO DATA 9.78E+03 TE-131 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00E+00 . 1 TE-132 2.13EM 6 9.43E%5 1.14E+06 1.37E+06 8.76E+06 NO DATA 9.50E+06 ! I-130 2.91E-06 5.89E-06 3,03E-06 6.49E-04 8.80E-06 NO DATA 2.75E-06 I I-131 1.65E+07 1.66E+07 9.46E+06 5.50E+09 2.73E+07 NO DATA 1.48E+06 l l I-132 1.05E-58 1.93E-58 8.86E-59 8.93E-57 2.95E-58 NO DATA 2.27E-58 I-133 5.75E-01 7.10E-01 2.69E-01 1.32E+02 1.18E+00 NO DATA 2.86E-01 0.00EMO 0.00E+00 0.00E+00 0.00EM O 0.00E+00 NO DATA 0.00E+00 l O 1-134 CLINTON-I 3-98 Rev.5-2/89
E ,
' CPS-ODCM i l i .!
l TABLE'3.51 25-(continued) f l MEAT PATHWAY FACTORS - R (CHILD) (m2 mrem /yr per pCi/sec) l ! ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI
- l. ISOTOPE
't I-135 6.86E-17. 1.23E-16 5.83E-17 l'.09E-14 1.89E-16 NO DATA 9.38E-17 CS-134 9.20E+08 1.51E+09 3.18E+08 NO DATA 4.68E+08 1.68E+08 8.14E+06 CS-136 1.62E+07 4.45E+07 2.88E+07 NO DATA 2.37E+07 3.53E+06 1.56E+06 CS-137 1.33E+09 1.27E+09 1.88E+08 NO DATA 4.15E+08 1.49E+08 7.98E+06 l CS-138 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00E+00 0.00E+00 0.00E+00 BA-139 0.00E+00 -0.00E+00 0.00E+00 NO DATA 0.00E+00 0.00E+00 0.00E+00 l
BA-140 4.38E+07 3.84E+04 2.56E+06 NO DATA 1.25E+04 2.29E+04 2.22E+07 BA-141 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00E+00- 0.00E+00 0.00E+00 BA-142 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00E+00 0.00E+00- 0.00E+00 LA-140 5.56E-02 1.94E-02 6.05E-03 NO DATA NO DATA NO DATA 5.41E+02 IA-142 6.18E-92 1.97E-92 6.17E-93 NO DATA NO DATA NO DATA 3.91E-87 CE-141 5.01E+04 1.11E+04 1.64E+03 NO DATA 4.85E+03 NO DATA 1.38E+07 CE-143 3.20E-02 1.74E+01 2.51E-03 NO DATA 7.28E-03 NO DATA 2.54E+02 CE-144 '2.31E+06 7.24E+05 1.23E+05 NO DATA 4.01E+05 NO DATA 1.89E+08 PR-143 3.34EM4 1.00E+04 1.66E+03 NO DATA 5.43E+03 NO DATA 3.60E+07 I PR-144 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00E+00 NO DATA 0.00E+00 ND-147 1.17E+04 9.47E+03 7.33E+02 NO DATA 5.20E+03 NO DATA 1.50EM7 W-187 3.21E-02 1.90E-02 8.53E-03 NO DATA NO DATA NO DATA ' 2.67E+00 NP-239 4.23E-01 3.04E-02 2.14E-02 NO DATA 8.79E-02 NO DATA 2.25E+03
- mrem /yr per pCi/m3 !
** 1.84 x 10-3 r
CLINTON-I 3-99 Rev.5-2/89 _ _ _ - - - - - - -- - - -- J
L CPS-0DCM N i-TABLE 3.5-26 h MEAT PATHWAY FACTORS - R (TEEN) (m2 mrem /yr peryCi/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE H-3 NO DATA 1.93EM2* 1.93E+02* 1.93E+02* 1.93E+02* 1.93E+02* 1.93+02* C-14 2.81E+05* 5.62E+04* 5.62E+04* 5.62E+04* 5.62E+04* 5.62E+04* 5.62E+04* NA-24 1.16E-03** 1.16E-03 1.16E-03 1.16E-03 1.16E-03 1.16E-03 1.16E-03 P-32 3.95E+09 2.45E+08 1.53E+08 NO DATA NO DATA NO DATA 3.32E+08 CR-51 NO DATA NO DATA 5.65E+03 3.14E+03 1.24E+03 8.07E+03 9.50E+05 MN-54 NO DATA 7.02E+06 1.39E+06 NO DATA 2.09E+06 NO DATA 1.44EM7 MN-56 NO DATA 1.17E-53 2.09E-54 NO DATA 1.48E-53 NO DATA 7.72E-52 FE-55 2.38ER 8 1.69E+08 3.94E+07 NO DATA NO DATA 1.07E+08 7.31EM 7 FE-59 2.12E+08 4.95E+08 1.91E+08 NO DATA NO DATA 1.56E+08 1.17E+09 C0-58 NO DATA 1.41E+07 3.25E+07 NO DATA NO DATA NO DATA 1.94E+08 i CO-60 NO DATA 5.84EM 7 1.32E+08 NO DATA NO DATA NO DATA 7.61E+08 NI-63 1.52E+10 1.07E+09 5.15E+08 NO DATA NO DATA NO DATA 1.71EM8 l NI-65 1.90E-52 2.43E-53 1.11E-53 NO DATA NO DATA NO DATA 1.32E-51 ! CU-64 NO DATA 2.06E-07 9.68E-08 NO DATA 5.21E-07 NO DATA 1.60E-05 ZN-65 2.50E+08 8.69E+08 4.05E+08 NO DATA 5.56E+08 NO DATA 3.68E+08 ZN-69 0.00E%0 0.00E+00 0.00E+00 NO DATA 0.00E+00 NO DATA 0.00E+00 i BR-83 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA ' NO DATA BR-84 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA BR-85 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA RB-86 NO DATA 4.05E+08 1.90E+08 NO DATA NO DATA NO DATA 6.00E+07 i RB-88 NO DATA 0.00E+00 0.00E+00 NO DATA NO DATA NO DATA 0.00E+00 i RB-89 NO DATA 0.00E+00 'O.00E+00 NO DATA NO DATA NO DATA 0.00E+00 ! SR-89 2.54E+08 NO DATA 7.27E+06' NO DATA NO DATA NO DATA 3.02E+07 l SR-90 8.04E+09 NO DATA 1.99E+09 NO DATA NO DATA NO DATA 2.26E+08 SR-91 1.20E-10 NO DATA 4.76E-12 NO DATA NO DATA NO DATA 5.45E-10 i SR-92 1.08E-49 NO DATA 4.59E-51 NO DATA NO DATA NO DATA 2.74E-48 Y-90 9.11EMI NO DATA 2.45E+00 NO DATA NO DATA NO DATA 7.51E+05 f CLINTON-I 3-100 Rev.5-2/89 ; i _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ J
CPS-0DCM TABLE 3.5-26 (continued) ([ [) MEAT PATINAY FACTORS - R (TEEN) (m2 mrem /yr pery Ci/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE Y-91m 0.00E+00 NO DATA 0.00E+00 NO DATA NO DATA NO DATA 0.00E+00 Y-91 9.55E+05 NO DATA 2.56E+04 NO DATA NO DATA NO DATA 3.91E+08 Y-92 1.26E-39 NO DATA 3.64E-41 NO DATA NO DATA NO DATA 3.45E-35 Y-93 3.70E-12 NO DATA 1.01E-13 NO DATA NO DATA NO DATA 1.13E-07 l ZR-95 1.50E+06 4.74E+05 3.25E+05 NO DATA 6.93E+05 NO DATA 1.09E+09 j ZR-97 1.70E-05 3.36E-06 1.55E-06 NO DATA 5.10E-06 NO DATA 9.11E-01 NB-95 1.79E+06 9.94E+05 5.47E+05 NO DATA 9.64E+05 NO DATA 4.25E+09 M0-99 NO DATA 8.20E+04 1.56E+04 NO DATA 1.88E+05 NO DATA 1.47E+05 TC-99m 3.42E-21 9.54E-21 1.24E-19 NO DATA 1.42E-19 5.29E-21 6.26E-18 l I TC-101 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00E+00 0.00E+00 0.00E+00 RU-103 8.57E407 NO DATA 3.66E+07 NO DATA 3.02E+08 NO DATA 7.16E+09 , RU-105 4.56E-28 NO DATA 1.77E-28 NO DATA 5.75E-27 NO DATA 3.68E-25 (Q/ RU-106 2.36E+09 NO DATA 2.97E+08 NO DATA 4.54E+09 NO DATA 1.13E+11 AG-110m 5.04E+06 4.77EM 6 2.90E+06 NO DATA 9.10E+06 NO DATA 1.34E+09 TE-125m 3.03E+08 1.09E+08 4.06E+07 8.47E+07 NO DATA NO DATA 8.95E+08 I TE-127m 9.40E+08 3.33E%8 1.12E+08 2.24E+08 3.81E+09 NO DATA 2.34E+09 ) TE-127 1.78E-10 6.30E-11 3.82E-11 1.23E-10 7.20E-10 NO DATA ' 1.37E-08 ! TE-129m 9.49E+08 3.52E+08 1.50E+08 3.06E+08 3.97E+09 NO DATA 3.56E+09 TE-129 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00EM O TE-131m 3.73E+02 1.79E+02 1.49E+02 2.69E+02 1.87E+03 NO DATA 1.44E+04 TE-131 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00E+00 TE-132 1.17E+06 7.38E+05 6.95E%5 7.78E+05 7.08E+06 NO DATA 2.34E%7 I-130 1.63E-06 4.71E-06 1.88E-06 3.84E-04 7.25E-06 NO DATA 3.62E-06 I-131 8.89E+06 1.24E+07 6.69E+06 3.63E+09 2.14E+07 NO DATA 2.46E+06 I-132 5.78E-59 1.51E-58 5.42E-59 5.09E-57 2.38E-58 NO DATA 6.58E-59 I-133 3.09E-01 5.25E-01 1.60E-01 7.32E+01 9.20E+01 NO DATA 3.97E-01 I-134 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00E+00 k,) < CLINTON I 3-101 Rev.5-2/89 __ _ -- ----- ---- - 8
I TABLE 3.5-26 (continued) l O "8^rr^ raw ^vr^croas-*L<r88") ! (m2 mrem /yr per pCi/sec) ORGAN: p0NE LIVER T,. BODY THYROID KIDNEY LUNG GI-LLI l ISOTOPE I-135 3.79E-17 9.75E-17 3.61E-17 6.27E 1.54E-16 NO DATA 1.08E-16 CS-134 5.22E+08 1.23E+09 5.70E+08 NO DATA 3.91E+08 1.49E+08 1.53E+07 CS-136 9.36E+06 3.68E+07 2.47E+07 NO DATA 2.01E+07- 3.16E+06 2.96E+06 CS-137 7.24E+08 9.63E+08 3.35E+08 NO DATA 3.28E+08 1.27E+08 1.37E+07 CS-138 0.00EM0 0.00E+00 0.00E+00 NO DATA 0.00E+00 0.00E+00 0.00E+00 BA-139 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00E+00 0.00E+00 0.00E+00 BA-140 2.37E+07 2.91E+04 1.53E+06 NO DATA 9.86E+03 1.96E+04 3.66E+07 BA-141 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00E+00 0.00E+00 0.00E+00 BA-142 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00E+00 0.00EM0 0.00E+00 LA-140 3.03E-02 1.49E-02 3.97E-03 NO DATA NO DATA NO DATA 8.56E+02 LA-142 3.37E-92 1.49E-92 3.72E-93 NO DATA NO DATA NO DATA 4.55E-88 CE-141 1.17E+04 7.83E+03 9.00E+02 NO DATA 3. 69 E+03 NO DATA 2.24EM7 CE-143 1.70E-02 1.24E+01 1.38E-03 NO DATA 5.55E-03 NO DATA 3.72E+02 CE-144 1.23E+06 5.10E+05 6.62E+04 NO DATA 3.04E+05 NO DATA 3.10EM 8 PR-143 1.77E+04 7.06E+03 8.80E+02 NO DATA 4.10E4 03 NO DATA 5.82E+07 PR-144 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00E+00 NO DATA 0.00E+00 ND-147 6.22E+03 6.76E+03 4.05E+02 NO DATA 3.97E+03 NO DATA ' 2.44EM7 W-187 1.74E-02 1.42E-02 4.96E-03 NO DATA NO DATA NO DATA 3.83E+00 NP-239 2.25E-01 2.12E-02 1.18E-02 NO DATA 6.67E-02 NO DATA 3.42EM3 i
- mrem /yr per pCi/m3
** 1.16 x 10~'
l 1 l 1 O CLINTON-I 3-102 Rev.5-2/89 i
CPS-0DCM l J TABLE 3.5-27 l
-s l ; MEAT PATHWAY FACTORS - R (ADULT) q (m2 mrem /yr per pCi/sec) l ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE H-3 NO DATA 3.24E+02* 3.24E+02* 3.24E+02* 3.24E+02* 3.24E+02* 3.24E+02*
C-14 3.33E+05* 6.66E+04* 6.66E+04* 6.66E+04* 6.66E+04* 6.66E+04* 6.66E+04* NA-24 1.45E-03** 1.45E-03 1.45E-03 1.45E-03 1.45E-03 1.45E-03 1.45E-03 P-32 4.65E+09 2.89E+08 1.80E+08 NO DATA NO DATA NO DATA 5.23E+08 CR-51 NO DATA NO DATA 7.05E+03 4.21E+03 1.55E+03 9.35E+03 1.77E+06 MN-54 NO DATA 9.19E+06 1.75E+06 NO DATA 2.738406 NO DATA 2.81E+07 MN-56 NO DATA 1.45E-53 2.57E-54 NO DATA 1.84E-53 NO DATA 4.62E-52 FE-55 2.94E+08 2.03E+08 4.74E+07 NO DATA NO DATA 1.13E+08 1.17E+08 FE-59 2.66E% 8 6.24E+08 2.39E+08 NO DATA NO DATA 1.74E+08 2.08E+09 CO-58 NO DATA 1.83E+07 4.09E%7 NO DATA NO DATA NO DATA 3.70E+08 CO-60 NO DATA 7.51E+07 1.66E+08 NO DATA NO DATA NO DATA 1.41E+09 O C/ NI-63 1.89E+10 1.31E+09 6.32E+08 NO DATA NO DATA NO DATA 2.73E+08 NI-65 2.27E-52 2.94E-53 1.34E-53 NO DATA NO DATA NO DATA 7.46E-52 CU-64 NO DATA 2.52E-07 1.18E-07 NO DATA 6.36E-07 NO DATA 2.15E-05 ZN-65 3.56E+08 1.13E+09 5.12E+08 NO DATA 7.57E+08 NO DATA 7.13E%8 ZN-69 0.00E+00 0.00E%0 0.00E+00 NO DATA 0.00E+00 NO DATA 0.00E+00 BR-83 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA BR-84 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA BR-85 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA RB-86 NO DATA 4.87E+08 2.27E+08 NO DATA NO DATA NO DATA 9.61E+07 RB-88 NO DATA 0.00E+00 0.00E+00 NO DATA NO DATA NO DATA 0.00E+00 RB-89 NO DATA 0.00E+00 0.00EM0 NO DATA NO DATA NO DATA 0.00E% 0 SR-89 3.01E+08 NO DATA 8.64E+06 NO DATA NO DATA NO DATA 4.83E+07 SR-90 1.24E+10 NO DATA 3.05E+09 NO DATA NO DATA NO DATA 3.59EM8 SR-91 1.43E-10 NO DATA 5.79E-12 NO DATA NO DATA NO DATA 6.83E-10 SR-92 1.28E-49 NO DATA 5.54E-51 NO DATA NO DATA NO DATA 2.54E-48 Y-90 1.09E+02 NO DATA 2.92E+00 NO DATA NO DATA NO DATA 1.15E+06 CLINTON-I 3-103 Rev.5-2/89
)
CPS-0DCM TABLE 3.5-27 (continued) ( ) MEAT PATINAY FACTORS - R (ADULT) (m2 mrem /yr per pCi/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI 1 ISOTOPE Y-91m 0.00E+00 NO DATA 0.00E+00 NO DATA NO DATA NO DATA 0.00E+00 Y-91 1.13E+06 NO DATA 3.03E+04 NO DATA NO DATA NO DATA 6.23E+08 Y-92 1.49E-39 NO DATA 4.36E-41 NO DATA NO DATA NO DATA 2.61E-35 Y-93 4.40E-12 NO DATA 1.21E-13 NO DATA NO DATA NO DATA 1.39E-07 ZR-95 1.87E+06 6.00E+05 4.06E+05 NO DATA 9.41E+05 NO DATA 1.90E+09 ZR-97 2.03E-05 4.10E-06 1.88E-06 NO DATA 6.17E-06 NO DATA 1.27E+00 NB-95 2.30EM 6 1.28E+06 6.86E+05 NO DATA 1.26E+06 NO DATA 7.75E+09 MO-99 NO DATA 9.91E+04 1.89E+04 NO DATA 2.24E+05 NO DATA 2.30E+05 TC-99m 4.32E-21 1.22E-20 1.56E-19 NO DATA 1.86E-19 5.99E-21 7.23E-18 TC-101 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00E+00 0.00E+00 0.00E+00 C \ Rif-103 1.05E+08 NO DATA 4.53E+07 NO DATA 4.02E+08 NO DATA 1.23E+10 RU-105 5.42E-28 NO DATA 2.14E-28 NO DATA 7.00E-27 NO DATA 3.32E-25 RU-106 2.81E+09 NO DATA 3.55E+08 NO DATA 5.42E+09 NO DATA 1.82E+11 AG-110m 6.67E+06 6.17E+06 3.67E+06 NO DATA 1.21E+07 NO DATA 2.52E+09 TE-125m 3.59E+08 1.30E+08 4.81E+07 1.08E+08 1.46E+09 NO DATA 1.43EM 9 TE-127m 1.12E+09 3.99E+08 1.36E+08 2.85E+08 4.54E+09 NO DATA 3.75E+09 TE-127 2.09E-10 7.52E-11 4.53E-11 1.55E-10 8.53E-10 NO DATA 1.65E-08 TE-129m 1.13EM 9 4.22E+08 1.79E+08 3.89E+08 4.73E+09 NO DATA 5.70E+09 TE-129 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00h+00 TE-131m 4.50E+02 2.20E+02 1.83E+02 3.48E+02 2.23E+03 NO DATA 2.18E+04 TE-131 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00E+00 TE-132 1.42E+06 9.21E+05 8.64E+05 1.02E+06 8.87E+06 NO DATA 4.36E+07 I-130 2.03E-06 5.98E-06 2.36E-06 5.07E-04 9.33E-06 NO DATA 5.15E-06 I-131 1.07E407 1.54E+07 8.80E+06 5.03E+09 2.63E+07 NO DATA 4.05E+06 I-132 7.13E-59 1.91E-58 6.67E-59 6.67E-57 3.04E-58 NO DATA 3.58E-59 I-133 3.70E-01 6.43E-01 1.96E-01 9.45E+01 1.12E+00 NO DATA 5.78E-01 / I-134 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00E+00 1 CLINTON-I 3-104 Rev.5-2/89 l _______________-_____a
CPS-0DCM l
)
i TABLE 3.5-27 (continued) ' ( ) MEAT PATHWAY FACTORS - R (ADULT) (m2 mrem /yr per pCi/sec) l t l ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE I-135 4.65E-17 1.22E-16 4.49E-17 8.03E-15 1.95E-16 NO DATA 1.38E-16 CS-134 6.53E+08 1.55E+09 1.27E+09 NO DATA 5.03E+08 1.67E+08 2.72E+07 CS-136 1.20E+07 4.75E+07 3.42E+07 NO DATA 2.65E+07 3.63E+06 5.40E+06 4 CS-137 8.69E+08 1.19EM9 7.78E+08 NO DATA 4.03E+08 1.34E+08 2.30E+07 CS-138 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00EM 0 0.00E+00 0.00E+00 BA-139 0.00E+00 0.00EM0 0.00E+00 NO DATA 0.00E+00 0.00E+00 0.00E+00 BA-140 2.88E+07 3.62E+04 1.89E+06 NO DATA 1.23E+04 2.07E+04 5.94E+07 BA-141 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00E+00 0.00E+00 0.00E+00 BA-142 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00E+00 0.00E+00 0.00E+00 LA-140 3.68E-02 1.85E-02 4.90E-13 NO DATA NO DATA NO DATA 1.36E+03 O LA-142 4.07E-92 1.85E-92 4.61E-93 NO DATA NO DATA NO DATA 1.35E-88 V CE-141 1.39E+04 9.43EM3 1.07E+03 NO DATA 4.38E+03 NO DATA 3.61EM7 I i CE-143 2.03E-02 1.50E% 1 1.66E-03 NO DATA 6.61E-03 NO DATA 5.61E+02 CE-144 1.46E+06 6.10E+05 7.83E+04 NO DATA 3.62E+05 NO DATA 4.93EM 8 PR-143 2.09E+04 8.40E+03 1.04E+03 NO DATA 4.85E+03 NO DATA 9.17EM 7 ) PR-144 0.00E+00 0.00E+00 0.00E+00 NO DATA 0.00E+00 NO DATA 0.00E+00 ND-147 7.04E+03 8.14EM3 4.87E+02 NO DATA 4.76E+03 NO DATA 3.91E+07 W-187 2.06E-02 1.72E-02 6.02E-03 NO DATA NO DATA NO DATA 5.64E%0 NP-239 2.57E-01 2.53E-02 1.39E-02 NO DATA 7.88E-02 NO DATA 5.18EM3 l l
- mrem /yr per y Ci/m3
** 1.45 x 10 '
l 0 O 1 CLINTON-I 3-105 Rev.5-2/89
CPS-0DCM TABLE 3.5-28 h VEGETATION PATHWAY FACTORS - R (CHILD) (m2 mrem /yr per pCi/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE H-3 NO DATA 4.01E+03* 4.01E+03* 4.01E+03* 4.01E+03* 4.01E+03* 4.01E+03* C-14 3.51E+06* 7.01E+05* 7.01E+05* 7.01E+05* 7.01E405* 7.01E+05* 7.01E+05* NA-24 3.75E+05** 3.75E+05 3.75E+05 3.75E+05 3.75E+05 3.75E+05 3.75E+05 P-32 3.37E+09 1.57E408 1.30E+08 NO DATA NO DATA NO DATA 9.30E+07 CR-51 NO DATA NO DATA 1.17E+05 6.49E+04 1.77E+04 1.18E+05 6.20E+06 MN-54 NO DATA 6.64E408 1.77E+08 NO DATA 1.86E+08 NO DATA 5.58E+08 I MN-56 NO DATA 1.87E+01 4.22E+00 NO DATA 2.26E+01 NO DATA 2.71E+03 FE-55 8.02E+08 4.25E+08 1.32E+08 NO DATA NO DATA 2.40E+08 7.88E+07 FE-59 3.98E+08 6.43E+08 3.21E+08 NO DATA NO DATA 1.87E+08 6.70E+08 CO-58 NO DATA 6.44E+07 1.97E+08 NO DATA NO DATA NO DATA 3. 76EM8 CO-60 NO DATA 3.79E+08 1.12E+09 NO DATA NO DATA NO DATA 2.10E+09 NI-63 3.95E+10 2.11E+09 1.34E+09 UO DATA NO DATA NO DATA 1.42E+08 NI-65 1.05E+02 9.89EM0 5.77E+00 NO DATA NO DATA NO DATA 1.21E+03 CU-64 NO DATA 1.09E+04 6.59E+03 NO DATA 2.64E+04 NO DATA 5.12E+05 ZN-65 8.11E+08 2.16E+09 1.34E409 NO DATA 1.36E+09 NO DATA 3.79E408 ZN-69 9.29E-06 1.34E-05 1.24E-06 NO DATA 8.14E-06 NO DATA 8.46E-04 BR-83 NO DATA NO DATA 5.40E+00 NO DATA NO DATA NO DATA ' NO DATA BR-84 NO DATA NO DATA 3.92E-11 NO DATA NO DATA NO DATA NO DATA BR-85 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA RB-86 NO DATA 4.53E+08 2.79E+08 NO DATA NO DATA NO DATA 2.91E+07 RB-88 NO DATA 4.38E-22 3.04E-22 NO DATA NO DATA NO DATA 2.15E-23 RB-89 NO DATA 4.69E-26 4.17E-26 NO DATA NO DATA NO DATA 4.09E-28 SR-89 3.59E+10 NO DATA 1.03E+09 NO DATA NO DATA NO DATA 1.39E+09 SR-90 1.24E+12 NO DATA 3.14E+11 NO DATA NO DATA NO DATA 1.67E+10 SR-91 5.21E+05 NO DATA 1.97E+04 NO DATA NO DATA NO DATA 1.15E+06 SR-92 7.29E+02 NO DATA 2.92E+01 NO DATA NO DATA NO DATA 1.38E+04 Y-90 2.31 E404 NO DATA 6.18E+02 NO DATA NO DATA h0 DATA 6.58E+07 CLINTON-I 3-106 Rev.5-2/89
.i.e. a.. . _ _
CPS-0DC24 l TABLE 3.5-28 (continued) [ VECETATION PATHWAY FACTORS - R 13(C m D) (m2 mrem /yr per pCi/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE { Y-91m 9.24E-09 NO DATA 3.36E-10 NO DATA NO DATA NO DATA 1.81E-05 Y-91 1.86E+07 NO DATA 4.97E+05 NO DATA NO DATA NO DATA 2.48E+09 Y-92 1.58E+00 NO DATA 4.52E-02 NO DATA NO DATA NO DATA 4.57E+04 Y-93 2.92E+02 NO DATA 8.01E+00 NO DATA NO DATA NO DATA 4.35E+06 ZR-95 3.86E+06 8.49E+05 7.56E+05 NO DATA 1.22E+06 NO DATA 8.86E+08 ZR-97 5.66E+02 8.18E+01 4.83E+01 NO DATA 1.17E+02 NO DATA 1.24E+07 NB-95 4.10E+05 1.60E+05 1.14E+05 NO DATA 1.50E+05 NO DATA 2.95E+08 MO-99 NO DATA 7.67E+06 1.90E+06 NO DATA 1.64E+07 NO DATA 6.35E+06 TC-99m 4.70E+00 9.21E+00 1.53E+02 NO DATA 1.34E+02 4.68E+00 5.24E+03 TC-101 1.48E-30 1.54E-30 1.96E-29 NO DATA 2.63E-29 8.16E-31 4.91E-30 RU-103 1.54E+07 NO DATA 5.90E+06 NO DATA 3.86E+07 NO DATA 3.97E+08 RU-105 9.16E+01 NO DATA 3.32E+01 NO DATA 8.05E+02 NO DATA 5.98E+04 RU-106 7.45E+08 NO DATA 9.30E+07 NO DATA 1.01E+09 NO DATA 1.16E+10 AG-110m 3.21E+07 2.17E+07 1.73E+07 NO DATA 4.04E+07 NO DATA 2.58E+09 TE-125m 3.51E+08 9.52E+07 4.68E+07 9.86E+07 NO DATA NO DATA 3.39E+08 TE-127m 1.32E+09 3.56E+08 1.57E+08 3.16Et08 3.77E+09 NO DATA 1.07E+09 TE-127 9.84E+03 2.65E+03 2.11E+03 6.81E+03 2.80E+04 NO DATA 3.84E+05 TE-129m 8.43E+08 2.35E+08 1.31E+08 2.72E+08 2.47E+09 NO DATA 1.03E+09 TE-129 1.32E-03 3.68E-04 3.13E-04 9.42E-04 3.86E-03 NO DATA 8.21E-02 TE-131m 1.54E+06 5.33E+05 5.67E+05 1.10E+06 5.16E+06 NO DATA 2.16E+07 TE-131 2.59E-15 7.89E-16 7.71E-16 1.98E-15 7.83E-15 NO DATA 1.36E-14 TE-132 7.00E+06 3.10E+06 3.74E+06 4.51E+06 2.88E+07 NO DATA 3.12E+07 I-130 6.10E+05 1.23E+06 6.35E+05 1.36E+08 1.84E+06 NO DATA 5.77E+05 I-131 1.43E+08 1.44E+08 8.16E+07 4.75E+10 2.36E+08 NO DATA 1.28E+07 I-132 9.20E+01 1.69E+02 7.77E+01 7.84E+03 2.59E+02 NO DATA 1.99E+02 l I-133 3.53E+06 4.36E+06 1.65E+06 8.11E+08 7.27E+06 NO DATA 1.76E+06 l I-134 1.50E-04 2.79E-04 1.28E-04 6.41E-03 4.26E-04 NO DATA 1.85E-04 l O CLINTON-I 3-107 Rev.5-2/89 L__-_-________-______-_______ >
CPS-0DCM TABLE 3.5-28 (continued) g VEGETATION PATHWAY FACTCRS - R (CHILD) (m mrem /yr per p Ci/sec) t ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE I-135 6.28E+04 1.13E+05 5.34E+04 1.00E+07 1.73E+05 NO DATA 8.61E+04 CS-134 1.60E+10 2.63E+10 5.55E+09 NO DATA 8.15E+09 2.92E+09 1.42E+08 i CS-136 8.23E+07 2.26E+08 1.46E+08 NO DATA 1.20E+08 1.80E+07 7.95E+06 CS-137 2.39E+10 2.29E+10 3.38E+09 NO DATA 7.46E+09 2.68E+09 1.43E+08 CS-138 6.44E-11 8.95E-11 5.68E-11 NO DATA 6.30E-11 6.78E-12 4.12E-11 BA-139 4.97E-02 2.65E-05 1.44E-03 NO DATA 2.32E-05 1.56E-05 2.87E+00 BA-140 2.77E+08 2.42E+05 1.62E+07 NO DATA 7.89E+04 1.45E+05 1.40E+08 BA-141 2.04E-21 1.14E-24 6.64E-23 NO DATA 9.88E-25 6.71E-24 1.16E-21 "A-142 9.70E-39 6.98E-42 5.42E-40 NO DATA 5.65E-42 4.11E-42 1.27E-40 LA-140 3.24E+03 1.13E+03 3.53E+02 NO DATA NO DATA NO DATA 3.16E+07 LA-142 3.39E-04 1.08E-04 3.38E-05 NO DATA NO DATA NO DATA 2.14E+01 CE-141 1.48E406 3.27E+05 4.85E+04 NO DATA 1.43E+05 NO DATA 4.08E+08 CE-143 1.71E+03 9.29E+05 1.35E+02 NO DATA 3.90E+02 NO DATA 1.36E+07 CE-144 1.27E+08 3.99E+07 6.79E+06 NO DATA 2.21E+07 NO DATA 1.04E+10 PR-143 1.45E+05 4.37E+04 7.22E+03 NO DATA 2.36E+04 NO DATA 1.57E+08 PR-144 5.64E-26 1.74E-26 2.84E-27 NO DATA 9.22E-27 NO DATA 3.75E-23 ND-147 7.16E+04 5.80E+04 4.49E+03 NO DATA 3.18E+04 NO DATA 9.18E+07 W-187 6.44E+O4 3.81E+04 1.71E+04 NO DATA NO DATA NO DATA - 5.36E+06 NP-239 2.56E+03 1.84E+02 1.29E+02 NO DATA 5.31E+02 NO DATA 1.36E+07
- mrem /yr per pCi/m3
** 3.75x10 5 O g CLINTON-I 3-108 .Ravd - 2 / 89 Rev.5
CPS-0DCM l t TABLE 3.5-29 l (9 v VEGETATION PATINAY FACTORS - R 1j (TEEN) j (m2 mrem /yr per p Cf./sec) j ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE H-3 NO DATA 2.59E+03* 2.59E+03* 2.59E+03* 2.59E+03* 2.59E+03* 2.59E+03* j C-14 1.45E+06* 2.91E+05* 2.91E+05* 2.91E+05* 2.91E+05* 2.91E+05* 2.91E+05* NA-24 2.40E+05** 2.40E+05 2.40E+05 2.40E+05 2.40E+05 2.40E+05 2.40E+05 P-32 1.61E+09 9.97E+07 6.24E+07 NO DATA NO DATA NO DATA 1.35E+08 CR-51 NO DATA NO DATA 6.12E+04 3.40E+04 1.34E+04 8.74E+04 1.03E+07 MN-54 NO DATA 4.54E+08 9.01E+07 NO DATA 1.36E+08 NO DATA 9.32E+08 MN-56 NO DATA 1.43E+01 2.54E+00 NO DATA 1.81E+01 NO DATA 9.41E+02 FE-55 3.26E+08 2.31E+08 5.39E+07 NO DATA NO DATA 1.46E+08 1.00E+08 FE-59 1.79ER8 4.18E+08 1.61E+08 NO DATA NO DATA 1.32E+08 9.88E+08 ! C0-58 NO DATA 4.36E+07 1.01E+08 NO DATA NO DATA NO DATA 6.02E+08 CO-60 NO DATA 2.49E+08 5.60E+08 NO DATA NO DATA NO DATA 3.24E+09 NI-63 1.61E+10 1.14E+09 5.46E+08 NO DATA NO DATA NO DATA 1.81EM 8 NI-65 5.73E+01 7.32E+00 3.34E+00 NO DATA NO DATA NO DATA 3.97E402 CU-64 NO DATA 8.28E+03 3.90E+03 NO DATA 2.10E+04 NO DATA 6.42E+05 ZN-65 4.23E+08 1.47E+09 6.86E+08 NO DATA 9.41E+08 NO DATA 6.23EM8 ZN-69 5.04E-06 9.60E-06 6.72E-07 NO DATA 6.28E-06 NO DATA 1.77E-05 BR-83 NO DATA NO DATA 2.93E+00 NO DATA NO DATA NO DATA NO DATA BR-84 NO DATA NO DATA 2.31E-11 NO DATA NO DATA NO DATA NO DATA BR-85 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA i RB-86 NO DATA 2.72E+08 1.28EM 8 NO DATA NO DATA NO DATA 4.02E+07 RB-88 NO DATA 3.17E-22 1.69E-22 NO DATA NO DATA NO DATA 2.72E-29 RB-89 NO DATA 3.56E-26 2.52E-26 NO DATA NO DATA NO DATA 5.45E-35 SR-89 1.51E+10 NO DATA 4.32E+08 NO DATA NO DATA NO DATA 1.80E+09 SR-90 7.50E+11 NO DATA 1.85E+11 NO DATA NO DATA NO DATA 2.11E+10 SR-91 2.82E+05 NO DATA 1.12E+04 NO DATA NO DATA NO DATA 1.28E+06 SR-92 4.00E+02 NO DATA 1.70E+01 NO DATA NO DATA NO DATA 1.02E+04 Y-90 1.25E+04 NO DATA 3.37E+02 NO DATA NO DATA NO DATA 1.03E+08 CLINTON-I 3-109 Rev.5-2/89
CPS-0DCM TABLE 3.5-29 (continued)
) VEGETATION PATINAY FACTORS - R (TEEN)
(m2 mrem /yr per pCi/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE Y-91m 5.04E-09 NO DATA 1.93E-10 NO DATA NO DATA NO DATA 2.38E-07 Y-91 7.84E+06 NO DATA 2.10E+05 NO DATA NO DATA NO DATA 3.21E+09 Y-92 8.60E-01 NO DATA 2.49E-02 NO DATA NO DATA NO DATA 2.36E404 Y-93 1.58E+02 NO DATA 4.34EM0 NO DATA NO DATA NO DATA 4.83EM6 ZR-95 1.73E+06 5.46E+05 3.75E+05 NO DATA 8.02E+05 NO DATA 1.26E+09 ZR-97 3.10E+02 6.14EM1 2.83EM1 NO DATA 9.31E+01 NO DATA 1.66E+07 NB-95 1.92E+05 1.07E+05 5.86E+04 NO DATA 1.03E+05 NO DATA 4.56E+08 MO-99 NO DATA 5.64E+06 1.08E+06 NO DATA 1.29E+07 NO DATA 1.01E+07 TC-99m 2.73E+00 7.61E+00 9.86E+01 NO DATA 1.13E+02 4.23E+00 5.00E+03 TC-101 8.02E-31 1.14E-30 1.12E-29 NO DATA 2.06E-29 6.95E-31 1.95E-37 RU-103 6.81E+06 NO DATA 2.91E+06 NO DATA 2.40E+07 NO DATA 5.69E+08 RU-105 4.97E+01 NO DATA 1.93E+01 NO DATA 6.27E+02 NO DATA 4.01E+04
;O) "
v RU-106 3.09E+08 NO DATA 3.89E+07 NO DATA 5.95EM8 NO DATA 1.48E+10 AG-110m 1.51E+07 1.43E+07 8.72E+06 NO DATA 2.73E+07 NO DATA 4.03E+09 TE-125m 1.49E+08 5.35E+07 1.99E+07 4.15E+07 NO DATA NO DATA 4.38E+08 TE-127m 5.52E+08 1.96E+08 6.57E+07 1.31E+08 2.24EM 9 NO DATA 1.38E+09 TE-127 5.40E+03 1.92E+03 1.16Et03 3.73E+03 2.19E+04 NO DATA 4.17E+05 TE-129m 3.60E+08 1.34E+08 5.70E+07 1.16E+08 1.51E+09 NO DATA . 1.35E+09 l TE-129 7.13E-04 2.66E-04 1.73E-04 5.09E-04 2.99E-03 NO DATA 3.90E-03 I TE-131m 8.44E+05 4.05E+05 3.38E+05 6.09E+05 4.22E+06 NO DATA 3.25E+07 TE-131 1.41E-15 5.80E-16 4.39E-16 1.08E-15 6.15E-15 NO DATA 1.15E-16 TE-132 3.91EM6 2.48E+06 2.33E+06 2.61E+06 2.37E+07 NO DATA 7.84E+07 I-130 3.50E+05 1.01E+06 4.05E+05 8.26E+07 1.56E+06 NO DATA 7.79E+05 I-131 7.66E+07 1.07E+08 5.76E+07 3.13E+10 1.85E+08 NO DATA 2.12E+07 i I-132 5.19E+01 1.36E+02 4.87E+01 4.58E+03 2.14E+02 NO DATA 5.91E+01 1-113 1.93E+06 3.28E+06 1.00E+06 4.58E+08 5.75E+06 NO DATA 2. 48EM6 I-134 8.44E-05 2.24E-04 8.03E-05 3.73E-03 3.53E-04 NO DATA 2.95E-06 l CLINTON-I 3-110 Rev.5-2/89 i l l b _ _ _ ________________________ _____._____.____ '
_ = _ _ _ ._. _ _ _ _ . _ _ - . __ ___ _ _ _ _ .___ _ _ _ - _ _ CPS-ODCM E TABLE 3.5-29 (continued) O vzo"'^'o">^'"w^'r^oroxs-x6("t") (m2 mrem /yr per pCi/sec) l l ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE I-135 3.53E+04 9.09E+04 3.37E+04 5.85E+06 1.44E+05 NO DATA 1.01E+05 CS-134 7.10E+09 1.67E+10 7.75E+09 NO DATA 5.31E+09 2.03E+09 2.08E+08 CS-136 4.37E+07 1.72E+08 1.16E+08 NO DATA 9.37E+07 1.48E+07 1.38E+07 CS-137 1.01E+10 1.35E+10 4.70E+09 NO DATA 4.59E+09 1.78E+09 1.92E+08 CS-138 3.54E-11 6.80E-11 3.40E-11 NO DATA 5.02E-11 5.84E-12 3.08E-14 ; BA-139 2.70E-02 1.90E-05 7.86E NO DATA 1.79E-05 1.31E-05 2.41E-01 BA-140 1.38E+08 1.69E+05 8.89E+06 NO DATA 5.73E+04 1.14E+05 2.13E+08 BA-141 1.11E-21 8.27E-25 3.70E-23 NO DATA 7.67E-25 5.66E-25 2.36E-27 BA-142 5.35E-39 5.35E-42 3.29E-40 NO DATA 4.53E-42 3.56E-42 1.64E-50 LA-140 1.80E+03 8.86E+02 2.36E%2 NO DATA NO DATA NO DATA 5.09E+07 f LA-142 1.88E-04 8.35E-05 2.08E-05 NO DATA NO DATA NO DATA 2.54E+00 ' CE-141 2.83E%5 1.89E+05 2.17E+04 NO DATA 8.90E+04 NO DATA 5.41E+08 f CE-143 9.33E+02 6.79E+05 7.58E+01 NO DATA 3.04E+02 NO DATA 2.04E+07 CE-144 5.29E+07 2.19E+07 2.84E+06 NO DATA 1.31E+07 NO DATA 1.33E+10 PR-143 7.00E+04 2.79E+04 3.48E+03 NO DATA 1.62E+04 NO DATA 2.30E+08 i l 1 PR-144 3.04E-26 1.24E-26 1.54E-27 NO DATA 7.14E-27 NO DATA 3.35E-29 i ND-147 3.62E+04 3.94E+04 2.36E+03 NO DATA 2.31E+04 NO DATA 1.42E+08 W-187 3.53E+04 2.88E+04 1.01EM 4 NO DATA NO DATA NO DATA 7.79E+06 NP-239 1.39EM3 1.31EM2 7.26E%1 NO DATA 4.10E+02 NO DATA 2.10E+07 i
- mrem /yr per yCi/m3
** 2.40x10 5 CLINTON-I 3-111 Rev.5-2/89
TABLE 3.5-30 g VEGETATION PATHWAY FACTORS - R (ADULT) l (m2 mrem /yr perp Ci/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE H-3 NO DATA 2.26EM3* 2.26E+03* 2.26E+03* 2.26E+03* 2.26E+03* 2.26E+03* C-14 8.97E+05* 1.79E+05* 1.79E+05* 1.79E+05* 1.79E+05* 1.79E+05* 1.79E+05* NA-24 2.71E+05** 2.71E+05 2.71E+05 2.71E+05 2.71E+05 2.71E+05 2.71E+05 P-32 1.40E+09 8.70E+07 5.41EM7 NO DATA NO DATA NO DATA 1.57E+08 CR-51 NO DATA NO DATA 4.60E+04 2.75E+04 1.01E+04 6.11E+04 1.16E+07 MN-54 NO DATA 3.13E+08 5.96E+07 NO DATA 9.30E+07 NO DATA 9.58E+08 MN-56 NO DATA 1.59E+01 2.82E+00 NO DATA 2.01E+01 NO DATA 5.06E+02 FE-55 2.10E+08 1.45E+08 3.38E+07 NO DATA NO DATA 8.10E+07 8.33E+07 FE-59 1.26E+08 2.96E+08 1.13E+08 NO DATA NO DATA 8.27E+07 9.86E+08 CO-58 NO DATA 3.08E+07 6.90E+07 NO DATA NO DATA NO DATA 6.24E+08 C0-60 NO DATA 1.67E+08 3.69E+08 NO DATA NO DATA NO DATA 3.14E+09 NI-63 1.04E+10 7.21E+08 3.49E+08 NO DATA NO DATA NO DATA 1.50E+08 NI-65 6.18E+01 8.03E+00 3.66E+00 NO DATA NO DATA NO DATA 2.04E+02 CU-64 NO DATA 9.16E+03 4.30E+03 NO DATA 2.31E+04 NO DATA 7.81E+05 ZN-65 3.18E+08 1.01E+09 4.57E+08 NO DATA 6.76E+08 NO DATA 6.36E+08 ZN-69 5.39E-06 1.03E-05 7.17E-07 NO DATA 6.69E-06 NO DATA 1.55E-06 BR-83 NO DATA NO DATA 3.13E+00 NO DATA NO DATA NO DATA 4.50E+00 BR-84 NO DATA NO DATA 2.54E-11 NO DATA NO DATA NO DATA ' 1.99E-16 BR-85 NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA RB-86 NO DATA 2.19E+08 1.02E+06 NO DATA NO DATA NO DATA 4.33E+07 RB-88 NO DATA 3.43E-22 1.82E-22 NO DATA NO DATA NO DATA 4.74E-33 RB-89 NO DATA 3.96E-26 2.79E-26 NO DATA NO DATA NO DATA 2.30E-39 SR-89 9.95E+09 NO DATA 2.86E+08 NO DATA NO DATA NO DATA 1.60E+09 SR-90 6.04E+11 NO DATA 1.48E+11 NO DATA NO DATA NO DATA 1.75E+10 SR-91 3.02E+05 NO DATA 1.22E+04 NO DATA NO DATA NO DATA 1.44E+06 SR-92 4.28E+02 NO DATA 1.85E+01 NO DATA NO DATA NO DATA 8.48E+03 Y-90 1.33E+04 NO DATA 3.56E+02 NO DATA NO DATA NO DATA 1.41E408 CLINTON-I 3-112 Rev.5-2/89
CPS-0DCM i l TABLE 3.5-30 (continued) VEGETATION PATINAY FACTORS - R (ADULT) I l (m2 mrem /yr per pCi/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI - ISOTOPE l Y-91m 5.42E-09 NO DATA 2.10E-10 NO DATA NO DATA NO DATA 1.59E-08 l l Y-91 5.12E+06 NO DATA 1.37E+05 NO DATA NO DATA NO DATA 2.82E+09 l Y-92 9.13E-01 NO DATA 2.67E-02 NO DATA NO DATA NO DATA 1.60E+04 Y-93 1.69E+02 NO DATA 4.65E+00 NO DATA NO DATA NO DATA 5.35E+06 , ZR-95 1.18E+06 3.79E+05 2.56E+05 NO DATA 5.94E+05 NO DATA 1.20E+09 ZR-97 3.36E+02 6.78E+01 3.10E+01 NO DATA 1.02EM2 NO DATA 2.10E+07 1 NB-95 1.42E+05 7.91E+04 4.25E+04 NO DATA 7.82E+04 NO DATA 4.80E+08 MO-99 NO DATA 6.12E+06 1.16E+06 NO DATA 1.39E+07 NO DATA 1.42E+07 TC-99m 3.09E+00 8.73E+00 1.11EM2 NO DATA 1.33E+02 4.28E+00 5.16E+03 ) TC-101 8.62E-31 1.24E-30 1.22E-29 NO DATA 2.24E-29 6.35E-31 3.73E-42 RU-103 4.77E+06 NO DATA 2.06E+06 NO DATA 1.82E+07 NO DATA 5.57E+08 RU-105 5.36E+01 NO DATA 2.12EMI NO DATA 6.93E+02 NO DATA 3.28E+04 t a RU-106 1.93E+08 NO DATA 2.44E+07 NO DATA 3.73E+08 NO DATA 1.25E+10 AG-110m 1.05E+07 9.75E+06 5.79E+06 NO DATA 1.92E+07 NO DATA 3.98E+09 TE-125m 9.67E+07 3.51E+07 1.30E+07 2.91E+07 3.93E+08 NO DATA 3.86E+08 TE-127m 3.49E+08 1.25E+08 4.26E+07 8.93E+07 1.42E+09 NO DATA 1.17E+09 TE-127 5.65E+03 2.03E+03 1.22E+03 4.19E+03 2.30E+04 NO DATA 4.46E+05 TE-129m 2.51E+08 9.35E+07 3.97EM7 8.61E+07 1.05E+09 NO DATA . 1.26E+09 : TE-129 7.61E-04 2.86E-04 1.85E-04 5.84E-04 3.20E-03 NO DATA 5.75E-04 TE-131m 9.12E+05 4.46E+05 3.72E+05 7.06E+05 4.52E+06 NO DATA 4.43E+07 TE-131 1.51E-15 6.32E-16 4.78E-16 1.24E-15 6.63E-15 NO DATA 2.14E-16 TE-132 4.31E+06 2.79E+06 2.62E+06 3.08E+06 2.68E+07 NO DATA 1.32E+08 I-130 3.91E+05 1.15E+06 4.55E+05 9.77E+07 1.80E+06 NO DATA 9.93E+05 I-131 8.07E+07 1.15E+08 6.62E+07 3.78E+10 1.98E+08 NO DATA 3.05E+07 I-132 5.77E+01 1.54E+02 5.40E+01 5.40E+03 2.46E+02 NO DATA 2.90Et01 1-133 2.09E+06 3.63E+06 1.11E+06 5.34E+08 6.34E+06 NO DATA 3.26E+06 I-134 9.33E-05 2.53E-04 9.06E-05 4.39E-03 4.03E-04 NO DATA 2.21E-07 O 1 CLINTON-I 3-113 Rev.5-2/89 !
CPS-0DCM TABLE 3.5-30 (continued) VEGETATION. PATHWAY FACTORS - R (ADULT) (m2 mrem /yr'per pCi/sec) ORGAN: BONE LIVER T. BODY THYROID KIDNEY LUNG GI-LLI ISOTOPE I-135 3.91E+04 1.02E+05 3.77E+04 6.75E+06 1.64E+05 NO DATA 1.16E+05' CS-134 4.67E+09 1.11E+10 9.08E+09 NO DATA 3.59E+09 1.19E+09 1.94E+08 CS-136 4.26E+07 1.68E+08 1.21E+08 NO DATA 9.35E+07 1.28E+07 1.91E+07' CS-137 6.36E+09 8.70E+09 5.70E+09 NO DATA 2.95E+09 9.82E+08 1.68E+08 CS-138 3.84E-11 7.58E-11 3.75E-11 NO DATA 5.57E-11 5.50E-12 3.23E-16 BA-139 2.86E-02 2.04E-05 8.38E-04 NO DATA 1.91E-05 1.16E-05 5.07E-02 BA-140 1.29E+08 1.62E%5 8.43E+06 NO DATA 5.50E+04 9.26E+04 2.65EM 8 BA-141 1.18E-21 8.90E-25 3.98E-23 NO DATA 8.'28E-25 5.05E-25 5.55E-31 BA-142 5.79E-39 5.96E-42 3.64E-40 NO DATA 5.03E-42 3.37E-42 8.16E-57 LA-140 1.98E+03 9.95E+02 2.63E+02 NO DATA NO DATA NO DATA 7.31E+07 l LA-142 2.04E-04 9.25E-05 2.31E-05 NO DATA NO DATA NO DATA 6.76E-01 CE-141 1.97E+05 1.33EM5 1.51E+04 NO DATA 6.19E+04 NO DATA 5.09E+08 O CE-143 9.98E+02 7.38E+05 8.17E+01 NO DATA 3.25E+02 NO DATA 2.76E+07 CE-144 3.28EM 7 1.37E+07 1.76E+06 NO DATA 8.14E+06 NO DATA 1.11E+10 PR-143 6.26E+04 2.51E+04 3.10E+03 NO DATA 1.45E+04 NO DATA 2.74E+08 PR-144 3.25E-26 1.35E-26 1.65E-27 NO DATA 7.61E-27 NO DATA 4.68E-33 ND-147 3.33E+04 3.85E+04 2.31E+03 NO DATA 2.25E+04 NO DATA 1.85E+08 W-187 3.80E+04 3.18E+04 1.11E+04 NO DATA NO DATA NO DATA - 1.40E+07 NP-239 1.43E+03 1.40E+02 7.74E+01 NO DATA 4.38E+02 NO DATA 2.88E+07
- mrem /yr per pCi/m3
. ** 2.71x10 5 O
CLINTON-I 3-114 Rev.5-2/89
CPS-0DCM
)
TABLE 3.5-31 l
)
GROUNDPLANEPATlWAYFACTORS-Rf , (m2 mrem /yr per pCi/sec) Total Total Total Isotope Body Skin Isotope Body Skin Isotope Body Skin 11 - 3 0.00E+00 0.00EMO Y-91 1.07E+06 1.21E+06 CS-136 1.51E+08 1.71E+08 . C-14 0.00E+00 0.00E+00 Y-92 1.80E+05 2.14E+05 CS-137 1.30E+10 1.52E+10 I NA-24 1.20E+07* 1.39E+07 Y-93 1.83E+05 2.50E+05 CS-138 3.59E+05 4.10E+05 i P-32 0.00E+00 0.00E+00 ZR-95 2.45E+08 2.85E+08 BA-139 1.06E+05 1.19E+05 ! CR-51 4.65E+06 5.50E+06 ZR-97 2.96E+06 3.44E+06 BA-140 2.05E+07 2.35E+07 ! MN-54 1.38E+09 1.62E+09 NB-95 1.37E+08 1.61E+08 BA-141 4.17E+04 '4.75E+04 l MN-56 9.03E+05 1.07E+06 M0-99 3.99E+06 4.62E+06 BA-142 4.49EM4 5.11E+04 FE-55 0.00E+00 0.00E+00 TC-99m 1.84E+05 2.11E+05 LA-140 1.92E+07 2.18E+07 FE-59 2.73E+08 3.20E+08 TC-101 2.03E+04 2.26E+04 LA-142 7.60E+05 9.12E+05 C0-58 3.80E+08 4.45E+08 RU-103 1.08E+08 1.26E+08 CE-141 1.37E+07 1.54E+07 CO-60 2.32E+10 2.73E+10 RU-105 6.36E+05 7.21E+05 CE-143 2.31E+06 2.63EM6 NI-63 0.00E+00 0.00E+00 RU-106 4.22E+08 5.06E+08 CE-144 6.96EM7 8.05E+07 O NI-65 2.97E+05 3.45E+05 AG-110m 3.44E+09 4.01E+09 PR-143 0.00E+00 0.00E+00 CU-64 6.05E+05 6.86E+05 TE-125m 1.56E+06 2.13E+06 PR-144 1.84E+03 2.11E+03 ! ZN 65 7.48E+08 8.60E+08 TE-127m 9.16E+04 1.08E+05 ND-147 8.39E+06 1.01E+07 ZN-69 0.00E+00 0.00E+00 TE-127 2.99E+03 3.29E+03 W-187 2.35E+06 2.73EM6 BR-83 4.87E+03 7.07E+03 TE-129m 1.98E+07 2.31E+07 NP-239 1.71E+06 1.98E+06 i BR-84 2.03E+05 2.36 EMS TE-129 2.64E+04 3.12E+04 BR-85 0.00E+00 0.00EM0 TE-131m 8.02E+06 9.46EM6 RB 8.98E+06 1.03E+07 TE-131 2.92E+04 3.45E+04 RB-88 3.31E+04 3.78E+04 TE-132 4.24E+06 4.99E+06 RB-89 1.23E+05 1.48E+05 I-130 5.50E+06 6.68E+06 SR-89 2.16E+04 2.50E+04 I-131 1.72E+07 2.09E+07 SR-90 NO DATA NO DATA I-132 1.25E+06 1.47E+06 SR-91 2.14E+06 2.51E+06 I-133 2.45E+06 2.98E+06 SR-92 7.77E+05 8.64E+05 I.-134 4.46E+05 5.30E+05 Y-90 4.50E+03 5.31E+03 I-l'15 2.53E+06 2.95E+06 7 Y-91m 1.00E+05 1.16E+05 CS-134 6.87E+09 8.01E+09 *1.20 x 10 CLINTON-I 3-115 Rev.5-2/89
'Ll CPS-0DCM aO j 4.0 COMPLIANCE WITH 40CFR190 i
- i. -CPS RETS 3.11.4 specifies that when the calculated doses ;
l associated with the effluent releases exceed twice the limits ! L of CPS RETS 3.11.1.2, 3.11.2.2 or 3.11.2.3, a Special Report j shall be prepared and submitted to the Commission. In ! addition, subsequent releases'shall be limited such that the dose or dose commitment to a real individual from all uranium fuel cycle sources is limited to 25 mrem to the total body l l or any organ (75 mrem to the thyroid) over l'2 consecutive 4 months. This Special Report.is to include an analysis which
. demonstrates that radiation exposures to all real individuals t from all uranium fuel cycle sources (including all liquid and gaseous effluent pathways and direct radiation) are less than . }
the standards in 40CFR190, ENVIRONMENTAL RADIATION PROTECTION ! STANDARDS FOR NUCLEAR POWER OPERATIONS. Ir analysis { l indicates that releases resulting in doses that exceed the : 40CFR190 standard could have occurred, and if the release condition'resulting in violation of 40CFR190 has not been corrected, then a variance from the Commission to permit such releases will be requested. ; i. The Special Report shall contain:
- 1. A determination of which uranium fuel cycle facilities LE or operations, in addition to CPS, contribute to the annual dose to the maximum exposed individual. Fuel !
cycle facilities located beyond the 5 mile radius from CPS need not be considered in rhi's determination.
. 2. A determination of the maximum exposed individual.
- 3. A determination of the total annual dose to the
., maximum exposed individual from all existing pathways - and sources of radioactivity and radiation (including direct radiation from N-16, the plant and storage facilities) using methodologies described in the ,
CPS-0DCM. The direct radiation dose may be either i calculated using NUREG-G133 methodology or measured. ! The total' body and organ doses resulting from liquid effluents will be summed with the doses resulting from i gaseous effluents (including non-noble gasas) and the doses ! to the maximum exposed individual from other operations of ! the uranium fuel cycle. The effluent doses will be based ! upon releases from CPS during the previous three quarters and from the quarter in which CPS RETS 3.11.4 was exceeded. i lt . O CLINTON-I 4-1 Rev.1-11/85
y__-___ I' 1 l l l I CPS-0DCM
/n l E l I
k'I 5.0 RADIOLOGICAL ENVIRONMEi4TAL MONITORING l l The Clinton Power Station (CPS) Radiological Environmental 1 Monitoring Program (REMP) implements CPS Technical 1 Specification 3/4.12.1. Table 5.0-1 and Figures 5.0-1, 5.0-2 l
.: and 5.0-3 describe the program required by the Technical 4 i l Specification. ]
Supplemental REMP samples required by commitments in the ) {, Environmental Report - Operating License Stage (ER-OLS) are J
' also described in Table 5.0-1 and Figures 5.0-1, 5.0-2 and 5.0-3.
In addition to the required sampling program, CPS will perform supplemental periodic and long term sampling and analyses in order to better monitor the environmental
! exposure pathways. These samples will not be listed in the ODCM, however, full sampic descriptions and results will be ' included in the Annual Radiological Environmental Operating Report.
Surface and drinking water samples are composited by collecting aliquots of fixed volume at fixed time intervals. This method of sampling is considered consistent with note -- (g) to CPS-TS Table 3.12-1.
/L ,)
(/ 5.1 INTERLABORATORY COMPARISON PROGRAM All analyses for CPS Radiological Environmental Monitoring Program are performed by Teledyne Isotopes Midwest Laboratories (TIML) located in Northbrook, Illinois. Teledyne Isotopes Midwest Laboratory (formerly Hazleton
! . Environmental Sciences) has participated in interlaboratory comparison (crosscheck) programs since the formulation of its l quality control program in December 1971. These programs , have been operated by agencies which supply l environmental-type samples (e.g., milk or water) containing concentrations of radionuclides known to the issuing agency but not to the participant laboratories. The purpose of such a program is to provide an independent check on the laboratory's analytical procedures and to alert it to any possibic problems, t
Participant laboratories measure the concentrations of specified radionuclides and report them to the issuing agency. Several months later, the agency reports the known values to the participant laboratories and specifies the range the results should fall within. Results consistently higher or lower than the known values and results outside the specified ranges indicate a need to check the instruments or procedures used. ( s) s_/ CLINTON-1 5-1 Rev. 2-10/86
i' s 1 L
, l r
CPS-0DCM L
; j?s. ' CPS has' received results obtained through.TIML's participation in the environmental sample.crosscheck program
[L p , for milk, water, air filters and rood samples du-ing the period 1980 through October 1985. ..This program has been i l
!- conducted by'the U.S. Environmental Protection. Agency .Intercomparison and Calibration Section,. Quality. Assurance Branch, . Environmental Monitoring and Support larboratory, Las Vegas, Nevada.
1 TIML has. published results for thermolumines' cent dosimeters
. (TLDs) during the period 1976, 1977, 1979, 1980, and 1981 F
through participation :ba the Second, Third, Fourth and Fif th . International Intercomparison of Environmental Dosimeters. s If the results of a determination in the EPA cro'sscheck j program are outside the control limits specified by the EPA, i; CPS will require TIML.to investigate the cause of the problem
, and take steps to correct it. The results of this investigation and corrective action shall be included in the Annual Radiological Environmental Operating Report. 'O LJ -
l-f l l 4 i I f O 5-2 Rev.2-10/86 CLINTON-I
l
< ' CPS-0DCM j i
1 . L Table-5.0-1 l '- RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM SAMPLING AND COLLECTION FREQUENCIES
, REQUIRED REQUIRED SAMPLING and TYPE and FREQUENCY EXPOSURE PATHWAY l i and/or SAMPLE TYPE COLLECTION FREQUENCY of ANALYSIS I
f TECHNICAL SPECIFICATION TABLE 3.12-1 REQUIREMENTS 5 i 1. DIRECT RADIATION Quarterly Gamma dose, quarterly Required: (1) An inner ring of stations, one in each meteorological sector in the general area of the SITE BOUNDARY:
'jECZO_R CODE DISTANCE from station (miles) j N CL-36 0.6 - 'I NNE CL-5 0.7 NE CL-22 0.6 ENE- CL-23 0.5 ;;;;g E CL-24 0.5 ESE CL-42 2.6 SE CL-43 2.8 !
- SSE CL-44 2.3 S CL-45 2.8 SSW .CL-46 2.8 SW CL-47 3.3 WSW CL-48 2.3 i W CL-1 1.8 ~
! WNW CL-34 0.8 . NW CL-35 0.7 i NNW CL-63 1.3 t
i !
-)
l l i
~
i O V
. CLINTON-I 5-3 Rev. 1-11/85
l CPS-0DCM S Table 5.0-1 (continued) Required: (2) An outer ring of stations, one in each sector in 6 to 8 km range (3.7 miles to 5.0 miles). SECTOR CODE DISTANCE f' rom station (miles) N CL-76 4.6 NNE CL-77 4.5 NE CL-78 4.8
. ENE CL-79 4.5 E CL-53 4.3 ESE CL-54 4.6 SE CL-55 4.1 SSE CL-56 4.1 S CL-57 4.6 SSW CL-58 4.3 SW CL-60 4.5 WSW CL-61 4.5 W CL-80 4.1 WNW CL-81 4.5 NW CL-51 4.4 ;;;;;;
NNW CL-52 4.3 9 (3) The balance of the stations to be placed in special interest areas such as population centers, nearby residents, schools, "
' and in 1 or 2 areas to serve as control stations.
SECTOR CODE DISTANCE from station (miles)
~~
N CL-37 3.4 N CL-75 0.94 ENE CL-65 2.6 E CL-41 2.4 S (control) CL-ll 16 W CL-49 3.5 - W CL-74 1.9 WNW CL-64 2.1 CLINTON-1 5-4 Rev. 1-11/85
i CPS-0DCM p) -' Table 5.0-1 (continued) l REQUIRED NUMBER OF REPRESENTATIVE REQUIRED SAMPLING REQUIRED TYPES
; EXPOSURE PATHWAY SAMPLES AND AND COLLECTION AND FREQUENCY i and/or SAMPLE TYPE SAMPLE LOCATIONS FREQUENCY OF ANALYSIS
- 2. AIRE 0RNE ,
Radioiodine and Samples from Continuous sampler Radiciodine Particulate 5 locations operation with cannister: sample collection 1-131 analysis weekly. weekly. Particulate Sampler: l a) 3 samples from Gross beta
, close to the 3 radioactivity SITE BOUNDARY analysis locations in following ' different sectors filter changes of the highest Gamma isotopic calculated annual analysis of ; average ground - composite (by a-s level D/Q. location,
(/~~/ quarterly). l SECTOR CODE DISTANCE from station (miles) NNE CL-2 0.7 NE CL-3 0.7 E CL-94 0.6
~' , b) 1 sample from the vicinity of a community having the highest calculated annual average l ground level D/Q.
SECTOR CODE DISTANCE from station (miles) E , CL-8 2.2 c) 1 sample from a control i location, as for example
; 15-30 km distant and in the least prevalent wind direction.
{ SECTOR CODE DISTANCE from station (milesi S (control) 16 (~' CL-11 ( CLINTON-1 5-5 Rev. 1-11/85 1 l
i
' CPS-0DCM' 'l l
Table 5.0-1 (continued) l REQUIRED NUMBER l- 0F REPRESENTATIVE REQUIRED SAMPLING REQUIRED TYPES EXPOSURE' PATHWAY SAMPLES AND AND COLLECTION AND FREQUENCY and/or SAMPLE TYPE SAMPLE LOCATIONS FREQUENCY OF ANALYSIS l
- 3. WATERBORNE
- a. Surface 1 sample up- Composite sample Gamma isotopic stream .
.over 1-month analysis 1 sample down- period monthly..
stream Composite for tritium analysis l quarterly. SECTOR CODE DISTANCE from station (miles) 6.1 l
, ENE (upstream) CL-91 SE (downstream) CL-90 0.4
- b. Ground Samples from Quarterly Gamma isotopic .,
.1- 1 or 2 sources and tritium only if likely analysis s_, to be affected. quarterly.
SECTOR . CODE DISTANCE from station (miles)
*E CL-12 1.6*
2.3 ESE CL-7D
- Sample location is in pump station distant from well. Well loc,ated 1.0 mile S of plant on the edge of the lake.
- c. Drinking 1 sample of each Composite sample I-131 analysis of 1 to 3 of the over 2-week on each
. nearest water period when composite for supplies that I-131 analysis the dose .' could be affected is performed, calculated for by its discharge.* monthly composite the consumption otherwise. of the water if greater than 1 mrem per year.
Composite for i gross beta and gamma isotopic analysis i monthly. - J Composite for ' tritium analysis O\ quarterly. CLINTON-I 5-6 Rev. 2-10/86
I i 1
- 1 I I
? l ! CPS-0DCM ;
~)
Table 5.0-1 (continued) REQUIRED NUMBER OF REPRESENTATIVE REQUIRED SAMPLING REQUIRED TYPES
. EXPOSURE PATHWAY SAMPLES ANL AND COLLECTION AND FREQUENCY and/or SAMPLE TYPE SAMPLE LOCATIONS FREQUENCY OF ANALYSIS l
4 [ c. Continued
*No municipal or public drinking water supplies are taken from Clinton Lake or downstream for 200 miles.
1 sample from a
; control location i
No control location necessary. I
- d. Sediment 1 sample from Semiannually Gamma isotopic from downstream analysis shoreline area with existing semiannually.
or potential recreational value. ... SECTOR CODE , DISTANCE from station (miles) SE CL-7B 2.1 i-
- 4. INGESTION
- a. Milk Samples from Semimonthly when Gamma isotopic milking animals animals are on and I-131 in 3 locations pasture, monthly analysis semi-within 5 km dis- at other times. monthly when
; tance having the animals are on highest dose pastures potential. monthly at If there are none, other times, then, 1 sample from milking animals in each of three areas between 5 to 8 km distant where doses are calculated to l be greater than 1 mrem per year.
l (~% CLINTON-1 5-7 Rev. 1-11/85
c- , 1 CPS-0DCM c x. i
!) ; Table 5.0-1 (continued) l REQUIRED NUMBER OF REPRESENTATIVE REQUIRED SAMPLING REQUIRED TYPES EXPOSURE PATHWAY SAMPLES AND AND COLLECTION AND FREQUENCY ]
and/or SAMPLE TYPE SAMPLE LOCATIONS FREQUENCY OF ANALYSIS No milking animals within 8 km of the site were identified in the most recent annual land use survey. 1 sample from : milking animals : at a control
' location, 15-30 km distant and in the e least prevalent wind direction. :
SECTOR CODE DISTANCE from station (miles) WSW (control) CL-116 14 l
- b. Fis'h and 1 sample of three Sample in season Gamma isotopic
. inverte- important species or semiannually analysis on brates (such as bass, if they are not edible portions.
crappie, carp,or seasonal, i bluegill) in ! i vicinity of l plant discharge. !) SECTOR CODE DISTANCE from station (miles) E CL-19 3.4 _. i e 4 1 sample of same < three species in areas not in-i fluenced by plant I discharge. l CODE DISTANCE from station (miles) t SECTOR S (control) CL-105 50
- c. Food 1 sample of each At time of harvest Gamma isotopic Products principal class analysis on of food products edible portions.
from any area that is irrigated - i by water in which ( liquid plant wastes f' have been dis-(N) charged *.
*No known usage of Salt Creek water for irrigation in DeWitt, Logan, Menard, or Cass Counties. This information is checked annually as part of the land use survey.
_ __--__-_____________ _ -- _CLINTON I 5-8 Rev. 2-10/86
}
- CPS'0DCM r~N Table 5.0-1 (continued) ]
N- 1 REQUIRED NUMBER - OF REPRESENTATIVE REQUIRED SAMPLING REQUIRED TYPES ; EXPOSURE PATHWAY SAMPLES AND AND COLLECTION AND FREQUENCY l and/or SAMPLE TYPE SAMPLE LOCATIONS FREQUENCY OF ANALYSIS l l
- c. Food Samples of 3 Monthly when Gamma isotopic Products different kinds available and I-131 f (Cont.) of broad leaf analysis, vegetation (such as lettuce, f cabbage, and swiss chard) grown nearest each of two l different !
offsite locations of highest pre-dicted annual l average ground- I level D/Q if 22 milk sampling
) is not performed.
(/ L. SECTOR CODE DISTANCE from station (miles) NE CL-115 0.9 N CL-117 0.9 1' sample of each of the similar broad leaf vege-tation grown 15-30 km distant in the least prevalent wind direction if milk sampling is not 1 performed. SECTOR CODE DISTANCE from station (miles) SSE (Control) CL-114 12.5 l l s_s CLINTON-I 5-9 Rev. 3-2/88
CPS-0DCM b Table 5.0-1 (continued) {
. . 1 REQUIRED SAMPLING REQUIRED TYPES i EXPOSURE PATHWAY AND COLLECTION AND FREQUENCY and/or SAMPLE TYPE FREQUENCY OF ANALYSIS j ENVIRONMENTAL REPORT (OPERATING LICENSE STAGE) 1 TABLE 6.1-6 REQUIREMENTS , . I.
l 1. Direct Radiation Quarterly Gamma dose, quarterly
. SECTOR CODE DISTANCE from station (miles)
NNE CL-2 0.7 i NE CL-3 0.7 l SW CL-4 0.8 5 WSW CL-6 0.8-l SE CL-7A 2.3
! E CL-8 2.2 I 2. Airborne Continuous sampler Radiciodine operation with sample cannister collection weekly, I-131 analysis composite quarterly, weekly. C Particulate Sampler:
Gross beta radioactivity analysis following I filter changes. Gamma isotopic >
> analysis of a composite (by ~' ! location, quarterly).
l-SECTOR CODE DISTANCE from station (miles) l W CL-1 1.8 SW CL-4 0.8
- WSW CL-6 0.8 SE CL-7A 2.3 i
i i O CLINTON-I 5-10 Rev. 2-10/86 1.
CPS-ODCM j
,~ 'T Table 5.0-1 (continued)
REQUIRED SAMPLING REQUIRED TYPES EXPOSURE PATHWAY AND COLLECTION AND FREQUENCY and/or SAMPLE TYPE FREQUENCY OF ANALYSIS
- 3. Surface Drinking Composite sample I-131 analysis Water over 2-week period on each composite
- when 1-131 analysis for the dose ; is performed calculated for monthly composite the' consumption otherwise, of the water if greater than 1 mrem per year. ! Composite for gross beta and i gamma isotpic
- analysis monthly.
Composite for I tritium analysis quarterly. ., SECTOR CODE DISTANCE from station (miles)
/ WNW CL-14 within service building
- 4. Surface Water Monthly grab Gamma isotopic sample composited analysis. Tritium quarterly by analysis on J location, quarterly composite. _
SECTOR CODE DISTANCE from station (miles) ESE CL-9 2.7 j ENE CL-10 5.0 l SW CL-13 3.6
- 5. Bottom Sediment Semiannual grab Gamma isotpic sample, analysis.
SECTOR CODE DISTANCE from station (miles) SE CL-7C 1.3
! SW CL-10 5.0 ,-m ../
CLINTON-1 5-11 Rev. 1-11/85
l
;. CPS- 0DCM h,
l- ) ' /Q , Q. Table 5.0-1 (continued) l REQUIRED SAMPLING REQUIRED TYPES EXPOSURE PATHWAY AND COLLECTION AND FREQUENCY , and/or SAMPLE TYPE FREQUENCY OF ANALYSIS y (
-6. Shoreline Sediment Semiannual grab. Gamma isotopic sample, a,nalysis .
SECTOR CODE DISTANCE from' station (miles) j ENE CL-10 5.0
- 7. Slime or aquatic Semiannual grab Gamma isotopic vegetation sample. analysis.
(periphyton). SECTOR CODE DISTANCE from station (miles) i SE CL-7C 1.3 ENE CL-10 5.0
- 8. Soil Every three years Gamma isotopic grab sample. analysis. =
SECTOR CODE DISTANCE from station (miles) W CL-1 1.8 NNE CL-2 0.7 NE CL-3 0.7 CL-4 SW 0.8 WSW CL-6 0.8 SE CL-7A 2.3 ~" i E CL-8 2.2 S CL-ll 16 r E CL-94 0.6 L 9. Ground Water Biweekly I-131 - biweekly Grab Gamma isotopic analysis and Gross beta analysis - monthly. Tritium analysis - quarterly
' composite of monthly.
SECTOR CODE DISTANCE from station.(miles) L E CL-12 1.6* i ESE CL-7D 2.3 . l I
- S. ample location is in pump station distant from well. Well located 1.0 mil,e S of plant on edge o lake.
CLINTON-1 5-12 Rev. 2-10/86
. _ _ _ _ _ - _ _ _ ._ .______________-_---_________-____________-______u
CPS-ODCM \ 1 1 /'3 FIGURE 5.0-1 j t v/ j l 1 REMP LOCAT7.ONS WITHIN 1.5 MILES OF CPS l' Yh. N. S
< t,, ' . . .,
5 h-
;.wwseuwwpm.w u M '
s-sI.<.3$'bT3 V.w@ h. . e.y%.Y 7
,v h..dhiM -g- :,- t.<
fi ji . h e 35 i,j ; ~ .,-/. ./
\ , I4 ~ ,, w. ~ - .z-
- w. .
.. ; x- '.; %_ . &m.as .,. _s e & . . : ~
gQ,,, ,. ~
~ '-
- s. n .e n.
.----- -n .tect te e IN, \i. . v~ .- ~ . ', ,,\- - 2e .
2 m m k bDa , . ,[,7 7, I ." [\ ..' , '% ... -'.[ [ ~j, j
%g m{l -
m h,,,T)qq.1 s :s
\frq.N w .-.,., n s%. . w 'ICfM h....-E
( ;. v. -_ 9 . ,. zu
- 21- ,
u w MUj,NfXMMWCW##A%1h-4 T T%.Y.8f-$I.-%'E. YN Yd.h$h;'k s. a.
,~ s. 4. %- , w. ..- .
o r r5W
'.......,,_I ,.. W. w , o' 4J. %i-y % m*- w y
s6 .
/~g . , . 27* - .
0 ( d k 34EMMhd@epg%' h J %r"
-a. v ,, q'g'; % Ng NM[M- ' t\ /- A' % & ,
I) ./ a (('b . 6 /
~
I.ee md m,
*~ ~ 1'- [ ~ .3 } } ;;, <. m.__ y ' / ,- .- -~ .>> Bot:nda t :
Scale , 00 f n c *Errvir or ns n: Sa=p 11 ng 1,oe p t im 5-13 Rev. 3-1/88 CLINTON-I
r CPS-ODCM FIGURE 5.0-2 REMP LOCATIONS WITHIN 6 MILES OF CPS ; i 1 Morth . l
- 1. a
. ,r, ,
tv.. n.
- i. ",s" . h '. 8[ D .j, "" ,
. , .* . - m... LN*
(SE 2. I* - -
. . ,,eiTT . ---.
- f. .
.,. -. &,* g.-. . .-. - . --.
u
.. . . s. ,.}l,S-. . I ' 'I 37 i s'1
- d4. l
=-& f .'s '. . 0. ,g%l n 7e= / _ .;g4 . .
4
- . Q,'
o . . . . , 3- $, *$! %
*i .
F , :[.*j .l /... 'i.'W/. .L-V '.i d
'. . .de 779. 'b/ '~ .N;g~ l fs% T l' J,. 3 j '. ., (,, }' j Trit. w I ,r r - ' "M. * 'g. . A' l, =
8 / , 4 $*[1Q- r 1. .....
~c . : ; }0 p\ Q ,. sr-h,'u~, * / ... [- l3 J =
m- k..~. . ..$.. j
~ '. L. . ..6 ,,
t .. M, .1 Jn u* a l.s .
-j _. ._ J .3,91 i ^"ri l-- .l.. -
tIw' ' I-
\'" (.. .. ; . .I Es.fi IN ' . 'w.giAQ . ni;4.':C'! 4 . 't M~
f
- 1. '.
- 4. . I ~N l .6 -
; , , , ' , ,s - .; r H . 1 Sj. , ,
l ., . .s s'u l D.E.y -,m 7'
.)e .<' ..
8
.l =
f - 8 t K . fr -
*ln 6- . 1 ,, d .
Scale Leg md Sit e Botada ry
~ ! ! usas 1 m1.1e 4 Enviror=e r:tsi Sacp ling 1.oca c I.:n l
I l CLINTON-I 5-14 Rev. 3-1/88
i I l' l ! 1 I CPS-0DCM ;
/3 I \ )
FIGURE 5.0-3 ; l Wi@ LOCATIONS WITHIN 50 MILES OF CPS
- a-~* i t l..
bI yff6 i...f 'l l l y--' '
'sNSIfr2b m
North - it' f ..'- . 5. y re . .
\ -a .lI3, t ) f ..
Ic,,,,,, gru, 4 .LI P.no jg. .. .
,,Nfidley.-,_di (hence .[,,ggury e .Fe,,es, ,,,v jd'5^yoa , e# , , )
h F 0 ,/ R o
..:, . , ~, .~p- ,!hII, ' ~a ) ~ /l' W,e '==#%
a.m.: [ j .!
,, j 4
1 5' dl.n.-.s.- I m V [; N',,s==aj l L t,,,,,,,,,,,, sis ,
.y Ibs("e y~ re Ep _._ s.
Blo_g. l, e.~ 3MYQ .. = %! ) ([s... ,'T
.. ; .: r-.. , * . mA_$g,4':y'Yr -- {, - - .u . ! M, u ...e uhr^ 6 ., f Q se.
2 ,. f'2 'S'
!(( Q p %s. ~,l y/w y !"~ 3 9 I ':,,..i a :::;:l'.y 6, p.vr[,.--
Il- L._s}M:sv 1 ,
- . _ _ , 'n - // . "'"u % -A 4V ,.L4F+ ~l,,rk g % h g.-- +I. - -s ,-L>%ha,, g., V, l \ %n ",i - [ * ^f."h.~ } bN2 " ,!~ ' [Y"9 d
T
.d ; ~ '~~ "'"*
k~ ,,,,c-/ d ***"'"'- [ , [ -
. ' \ won. -"'% *"" 4, O "" '
D *"** 9
&\,N Ml / D%, V ' Q'~a i ,,g/:P ll-N)&*%
18 nores
,n D )E , W ,I umihew ,,,,,,,,3 ,
7 w*
*'"d i -94 Cl*4.c .,,i i
tra %: " 8 * - d ga $ Al 'i G h(.2 I l
; y , $ pe:=**A" l*i-t ' I "";B . "
V
. ga %%ne:.::.F~,m/* ysi - > y "/ w.gf9Q %
2 P"/ Y% p
, g 'J"'~ ',(astMQ~ g f*4. "=[; P e ey'f ~ "" %i r~
_ . pa -.a!. .W ... .-
,ygv f . ,g / . 8 ID ! ~~- kfe" S' f /, .M < }* ' JT Tl %@4]fl"'
p ' e s. ,
ami ~
4
- p. !
y v,.k:
~"
yF g k M(,.m #[ :~ cro..ii.j' .i Mh [ ,9 i m .,.,~=Q, i k._ . g ..g).. c. ."' u,
,,D_ %y.s ~ g a, .-.., . -. '- .o.., O / ' ~. 'P ~ . .- . , .. ,a f M .- 5 / 6,,,,
w.,,ltt. yr[rN - i A,' , f e !%'l. P""*" li . 4 l-te'.
*~
as MN-ma f oi; l
' I i "f*o """. $
Q,o NjG','arh.@a - G N_7... ^Mw{.,,,j%,%={hg l g%$mah/<m'f lit 4 Tdiy". 3T ,,h- %
- r. _ *
*= j " ' ,,8 y> --1 . ". am"s ' . W"nd .' Mm;,LW'P" '.k;%E .'* * .l N,,i -/,/ .0 %. ' f. .~t . , 'O' ==w.>..
r-
< f oNp gh ;:g.c t'b*g ;;;,;;;;O.t.;i-' . ; .p ;// !"'% ['~"'"'hp ?.t- b Mn,,,.' r-- lt,I .
W ".'+ #
- G. 4
, ma%.?_ . g -4 ca 1 ! W j eiue mmend /.S""*" '
0'" '"' MOU T, R
- I E
.g/
r+<3:
.c== = h h7 . * (. :.L,,.,. ; ,,, ,
P'Ql" ":: ~e.g d;4/ Rl ._y/.[.h,J=b
! .'42 .,,ql,,,, #.~~'I-~'._._._ - \[:hi ~~i ~ ' t, : %,,,,,, ,-,,p3 . "ya** .y,,,W-W . Ma.*e q,9 : i d""N*P. .c, /. _.,. ..p%'T g,n.P.a.T )'. ;P an m 9:g* q, . T .go5.ville . ~ , <fpp.~lg .w m.
v : 3 *I f .I g l l
..A 4,N *, ~
i
'I*" . 1' , ,, 4 ~ .: ). i l*""y; % ' . a'i d g'?g;%
e} t V Scale # Environment l Sampling Loca tion 10 miles CLINTON-1 5-15 Rev. 2-10/86
- 7. ,
1 CPS-0DCM r~N ' - 5
'- 6.0 ADJUSTMENT C/ THE CPS ODCM METHODOLOGY l Cons $ stent with the NRC Commissioners' opinion on 10CFR50 Appeidix I dated April 30, 1975, CPS will use environs monitoring data to improve dose calculational models and to ; request CPS ODCM changes on the basis of such operating l , experience data. Such adjustments are recognized as being j especially important for the radiciodine-milk pathway where conservative regulatory guide assumptions have been made. B' -
using environs monitoring data, uncertainties associated with plume behavior, radiciodine chemical form, deposition and retention on forages, and milk consumption patterns may be
, circumvented or reduced.
f l l t Ms l 3s l / ) Uj.-
\
1 l i ', I t 1 l l l -. xg/ CLINTON-1 6-1 Rev.2-10/86 w__________-__. _ _ _ _ .
CPS-0DCM
~ <N
' () i ; 7.0 ATMOSPHERIC TRANSPORT AMD DISPERSION MODEL 7.1 Introduction The atmospheric transport and dispersion model used by i Illinois Power Company is a straight-line, - sector-averaged Gaussian model designed to estimate average relative concentrations at various receptor points. The model was developed in accordance with routine release analysis procedures specified by Regulatory Guide 1.111 (Revision 1 July 1977), Section C.1.'c " Constant Mean Wind Direction Models". All meteorological and dose calculations prescribed in this manual for long-term releases are based on meteorological data acquired onsite for the period i April 1975 through March 1976. This period of record was selected from five years of data (April 1972 through March 1977) and represents conservative dispersion conditions and highest data recovery. Acquired meteorological data will be reviewed and X/Q values updated, if necessary, in the SEMIANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT. Even though the CPS RETS utilize historical annual average dispersion conditions in determining the (N Limiting Condition for Operation (LCO) for radioactive (_,) materials in gaseous effluents, annual hourly meteorological data will also be collected and summarized. This summary may either be included in the first half year SEMIANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT or retained onsite in a file that shall be provided to the NRC upon request.
~
The methodology utilized in calculating the undecayed, undepleted dispersion (Table 7.2-1) and deposition (Table 7.2-2) values is described in section 7.2. Near-real time meteorological data processing is
- described in section 7.3. Site boundary dispersion parameters are listed in Table 7.2-5.
7.2 Historical Meteorological Data Processing The data presented in Tables 7.2-1 and 7.2-2 are based upon data acquired by a single onsite meteorological tower instrumented at the 10 and 60 meter heights with temperature, wind speed and wind direction sensors i (see Figure 5.0-1 for tower location). Discharge I point characteristics (refer to Table 7.2-4) permit use of the mixed-mode dispersion model for all calculations. Therefore, two stability wind roses, elevated and ground, were developed jointly by considering the wind data hour by hour. Wen the exit velocity to wind speed ratio indicates the release (("N,,/ should be considered as elevated, the upper level data is used: as ground, lower level data. CLINTON-I 7-1 Rev.2-10/86
CPS-0DCM () Reported wind speeds which are less than the anemometer's threshold are assigned a value equal to one-half of threshold speed. For reported wind speeds which are less than the direction vane's threshold, a direction is assigned in proportion to the observed wind direction distribution of the lowest noncalm speed class. Refer to Table 7.2-3 for the wind direction and windspeed classification criteria. 7.2.1 Numerical Model The constant mean wind direction model assumes that the effluent is uniformally distributed within each downwind sector and that the release rate is constant during the time period considered by the model. The concentration to source term ratio (X/Q) at any downwind location is calculated by equation (1): 2 X(R,0) = 2.032 i J^ f(u,0,s) (uS.)-1 exp -0.5[h,\ (1) Q 'Y d s 1 where -
\5z/-
X/Q (R,0) = Relative effluent radionuclides plume O concentration at distance R and direction 0, sec/m3 2.032 = The constant (2/n)U divided by the width, in radians, of a 22.5' sector (r/8), dimensionless R = Distance downwind to receptor point (RTO), meter 0 = Downwind direction to receptor point (R,0), degreee or sector u = Wind speed, m/sec s = Pasquill atmospheric stability class, A through G f = Observed joint trequency in which the wind blows with speed u in downwind direction and atmospheric stability class s, dimensionless S
= Vertical dispersion coefficient corrected '
ror building wake effects, meter - h, = Effective effluent release height, meter CLINTON-1 7-2 kev.1-11/85
_ _ _ _ __ = . _ _ _ _ . . _ , _ _ _ _ . _ _ _ _ - - _ _ _ _ _ _ _ _ _ - _ _ _ - -
~ E. ^
CPS-0DCM.
;1; /T Atmospheric stability is classified'as follows:.
V Pasquill Stability Temperature Lapse Rate (*C/100m) ik (Extremely' Unstable)
< -1. 9 B -1.9'to -1.7 C -1.7 t,o -1.5 D (Neutral) -1.5 to -0.5 E -0.5 to 1.5 F 1.5 to 4.0 G (Extremely Stable) > 4.0 7.2.2 Source Configuration Considerations In the mixed-mode model,.the height of the release is proportioned between elevated (discharge point height plus mementum plume rise) and ground (discharge point.
height equal to zero) levels. Separate-wind and stability data are used for each release height and corresponding X/Q O ratios calculated. time the plume is considered ground level, G , is determined from the ratio of'the The fraction of the discharge point vertical exit velocity to-the wind speed, W /u, and by.the following o l relationships
- W /u < l.0
~
1.00 4 2.58-1.58(W /u) : 10< u < 1. 5 G U
= 0.3-0.06(W fu) ~ s 1.5 < W u-< 5.0 0.00 : W,/u2 .0 l It follows that the release can be considered as ground level 100G percent of the time and elevated 100(1-Gt) pIrcent of the time.
t CLINTON-I 7-3 Rev.1-11/85
CPS-0DCM To calculate ground level X/Q, equation O - (1) is used with the effective effluent release height set to zero (h,= 0). The correction factor applied to the vertical dispersion coefficient, S , to account for increased plume. mixing within the building wake is determined by equation (2):
= [c z2 + Dz8/2n]% (2) ~
S z with the restriction that Szj (3)E og where D.,
= Maximum height of neighboring structure causing wake effects, meter og = Vertical dispersion coefficient, meters = aRb + C (below) j,1000 STABILITY 100 < R < 1000 R >1000 CLASS a b c a b c A 0.00066 1.941 9.27 0.00024 2.094 -9.6 B 0.0382 1.149 3.3 0.055 1.098 2.0 C 0.113 0.911 0.0 0.113 0.911 0.0 D 0.222 0.725 -1.7 1.26 0.516 -13.0 E 0.211 0.678 -1.3 6.73 0.305 -34.0 F 0.086 0.74 -0.35 18.05 0.18 -4&.6 G 0.052 0.74 -0.21 10.83 0.18 -29.2 The expression for o g simulates Regulatory Guide 1.111, Figure 1.
7.2.3 Relative Deposition Factor (D/Q)
- Using stability wind rose meteorological data, relative deposition is calculated using equation (3):
D/Q = 16 2nk ff(0,s)Dr (3' N' h s} '" (3) where . D r
= Relative deposition rate, m"1 - Deposition rate per unit downwind distance (pC1/sec-m) divided by the source term (pCi/sec)
CLINTON-I 7-4 Rev.1-ll/85
?>
+ '
i
. CPS-0DCM- , /~~'\ 'g_) For mixed-mode releases, the relative deposition rate is calculated using the following equation (Dr )m = Gt (Dr )g + (1-Gt ) (Dr)e '" (0) where (Dr )m = Relative deposition rate of ;
mixed-mode releases, m-1 l I (Dr )g Relative deposition rate of I ground-level releases, m-1 (Regulatory' Guide 1.111, Figure 6) (Dr }e - Relative deposition rate of elevated' releases', m-1 (Regulatory Guide 1.111, Figure 8) t I k O . O - i l l o l 4 9
- 1
l CPS-0DCM m ; Table 7.2-1 ! (v) ] ANNUAL AVERAGE MIXED-MODE X/Q I April 1975 - April 1976 ) Distance Sector (meter) N NNE NE ENE E ESE SE SSE 1.00+002 7.986 005 5.540 005 4.923-005 3.079-005 3.455-005 2.890-005 2.325-005 1.978-005 l 6.672 005 4.628 005 4.117 005 2.574-005 2.886 005 2.412-005 1.943 005 1.655-005 1.10+002 1.20+002 5.668-005 3.931-005 3.500-005 2.188-005 2.452 005 2.048-005 1.650-005 1.408-005 1.30+002 4.883-005 3.386 005 3.017-005 1.886 005 2.112-005 1.763-005 1.422-005 1.214 005 1.40+002 4.256-005 2.951-005 2.631 005 1.644-005 1.840-005 1.535-005 1.239-005 1.059-005 1.50+002 3.749-005 2.599-005 2.318-005 1.449 005 1.621-005 1.353-005 1.091-005 9.336-006 l' 1.60+002 3.3'1 005 2.309 005 2.062-005 1.287-005 1.440-005 1.203-005 9.700-006 8.305 006 1.70+002 2.982-005 2.067-005 1.847-005 1.153 005 1.289-005 1.078-005 8.684-006 7.442 006 1.80+002 2.688-005 1.862 005 1.665 005 1.039-005 1.162 005 9.717-006 7.827 006 6.712-006 I 1.90+002 2.437-005 1.688-005 1.511-005 9.418-006 1.053 005 8.813 006 7.096-006 6.C88-006 l I 2.00+002 2.221 005 1.538 005 1.377-005 8.583 006 9.598-006 8.035-006 6.467-006 5.551-006 2.10+002 2.033-005 1.408-005 1.262 005 7.859-006 8.788 006 7.360-006 5.921-006 5.085-006 2.20+002 1.870-005 1.295 005 1.160-005 7.227-006 8.080 006 6.769-006 5.445-006 4.678-006 2.3O+002 1.726 005 1.195-005 1.072 005 6.672-006 7.458 006 6.250-006 5.027-006 4.320-006 2.40+002 1.599-005 1.107-005 9.930-006 6.181-006 6.909-006 5.791 006 4.658-006 4.003-006 2.50+002 1.487 005 1.029-005 9.236-006 5.747-006 6.424-006 5.387-006 4.332-006 3.724-006 2.60+002 1.391 005 9.630*006 8.641-006 5.376-006 6.017 006 5.053 006 4.059-006 3.488-006 l 2.70+002 1.304-005 9.034 006 8.106 006 5.041-006 5.650-006 4.751-006 3.814-006 3.276-006 2.80+002 1.226 005 8.495-006 7.622 006 4.739 006 5.318 006 4.477-006 3.591 006 3.084-006 2.90+002 1.155-005 8.006-006 7.183-006 4.465-006 5.016-006 4.228-000 3.389-006 2.909-006 3.00+002 1.091 005 7.560-006 6.784-006 4.216-006 4.740-006 4.000-006 3.205-006 2.750 006 3.20+002 9.779 006 6.781 006 6.084-006 3.779-006 4.258 006 3.600 006 2.881-006 2.471-006 A 3.40+002 8.825-006 6.122 006 5.494-006 3.411 006 3.849-006 3.260 006 2.607 006 2.235-006 3.60+002 8.011-006 5.561 006 4.990 006 3.096-006 3.500-006 2.970-006 2.373 006 2.032-006 (-) l 3.80+002 4.00+002 7.324 006 5.088 006 4.564 006 2.830-006 3.203-006 2.722 006 2.173-006 1.860 006 6 756-006 4.695-006 4.210 006 2.608-006 2.953-006 2.513 006 2.005 006 1.712 006 i 4.20+002 6.256 006 4.350-006 3.898-006 2.412-006 2.733 006 2.329-006 1.857-006 1.583-006 4.40+002 5.813 006 4.044 006 3.622-006 2.239-006 2.538 006 2.166-006 1.725-006 1.469-006 4.60+002 5.418-006 3.771-006 3.377-006 2.086 006 2.365-006 2.021-006 1.608-006 1.367-006 4.80+002 5.064-006 3.E27 OO6 3.157 006 1.948-006 2.210 006 1.890 006 1.504 006 1.276 006 5.00+002 4.746-006 3.307-006 2.959 006 1.824-006 2.070-006 1.773 006 1.410-006 1.194-006 5.20+002 4.459-006 3.108-006 2.780-006 1.713-006 1.944-006 1.667-006 1.325-006 1.121-006 5.40+002 4.198-006 2.928 006 2.619 006 1.612 006 1.830 006 1.571 006 1.247-006 1.054-006 5.60+002 3.961-006 2.763 006 2.471-OOC 1.520-006 1.726-006 1.484-006 1.177 006 9.938-007 5.80+002 3.745 006 2.613-006 2.337 006 1.436-006 1.631-006 1.404-006 1.113-006 9.387 007 6.00+002 3.547-006 2.476 006 2.214-006 1.359 006 1.544-006 1.330-006 1.055-006 8.884-007 6.50+002 3.119-006 2.179 006 1.948 006 1.194-006 1.357-006 1.172-006 9.282-007 7.799-007 7.00+002 2.773 006 1.939 006 1.734 006 1.061 006 1.204-006 1.043-006 8.261 007 6.924-007 7.50+002 2.494-006 1.746-006 1.563 006 9.561-007 1.079 006 9.378 007 7.440-007 6.221-007 8.05+002 2.237-006 1.568-006 1.405-006 8.591-007 9.649-007 8.413-007 6.687 007 5.577-007 8.50+002 2.056-006 1.442-006 1.293 006 7.903-007 8.843-007 7.730-007 6.154-007 5.124-007 9.00+002 1.881-006 1.321-006 1.186 006 7.243 007 8.073-007 7.076-007 5.645-007 4.692 007 9.50+002 1.729 006 1.216-006 1.092-CO6 6.670-007 7.407-007 6.508 007 5.204-007 4.319-007 1.00+003 1.602-006 1.128-006 1.013 006 6.186-007 6.851-007 6.022-007 4.834-007 4.004-007 1.10+003 1.379-006 9.730-007 8.750-007 5.340-007 5.881 007 5.194-007 4.189-007 3.463-007 1.20+003 1.203-006 8.516-007 7.665 007 4.679-007 5.127-007 4.546-007 3.685-007 3.042-007 - l 1.3O+003 1.063-006 7.543 007 6.795-007 4.149-037 4.527-007 4.026-007 3.282-007 2.705-007 1.40+003 9.537 007 6.780-007 6.110-007 3.735*007 4.066-007 3.616-007 2.966-007 2.445-007 1.50+003 8.660-007 6.169-007 5.559-007 3.404-007 3.704-007 3.287-007 2.714-007 2.238-007 1.61+003 7.852 007 5.606 007 5.053 007 3.099 007 3.370-007 2.984-007 2.482-007 2.048-007
*7.986 x 10-5 sec/m 3 l CLINTON-I 7-6 Rev.2-10/86 {
1 l ( l l
i i CPS-0DCM i i Table 7.2-1 (Continued) V I ANNUAL AVERAGE MIXED-MODE X/Q April 1975 - April 1976 _ l Distance Sector . (meter) NE ENE E ESE- SE SSE N NNE 4.820-007 4.347 007 2.673 007' 2.903-007 2.561-007 2.157 1.782 007 1.80+003 6.724-007 1.893007 007 1.566 007 2.00+003 5.816 007 4.187 007 3.779-007 2.330-007 2.524 007 2.220-007 1.953-007 1.684-007 1.395 007 2.20+003 5.104 007 3.690-007 3.334-007 2.059 1,828 007 007 2.230 1.976 007 007 1.726-007 1.505-007 1.247 007 4.496-007 3.265 007 2.954 007 2.41+003 1.795 007 1.563 007 1.375-007 1.140 007 2.60+003 4.065 007 2.963-007 2.683 007 1.663 007 2.80+003 3.677 007 2.689 007 2.438-007 1.513 007 1.632 007 1.417 007 1.258-007 1.043 007 3.349-007 2.458-007 2.231-007 1.386 007 1.493-007 1.293-007 1.157-007 9.598 008 3.00+003 007 1.179 007 1.063-007 8.817 008 3.22+003 3.046-007 2.243 007 2.038-007 1.268 007 1.364 2.620-007 1.940-007 1.766-007 1.101-007 1.182 007 1.017-007 9.283 008 7.702 008
' 3.60+003 4.02+003 2.258-007 1.681-007 1.533-007 9.571 008 1.026-007 8.790-008 8.115 008 6.735 008 4.40+003 2.003 007 1.497-007 1.368 007 8.551 008 9.156-008 7.816-008 7.277-008 6.040 008 4.83+003 1.770 007 1.328-007 1.215-007 7.606-008 8.135 008 6.917-008 6.495-008 5.391 008 5.00+003 1.689 007 1.269 007 1.162-007 7.278 008 7.780-008 6.605-008 6.221-008 5.163 008 5.JO+003 1.603 007 1.206 007 1.105-007 6.926 008 7.401 008 6.273 008 5.927-008 4.919 4.455 008 008 5.63+003 1.442 007 1.088-007 9.975 008 6.261-008 6.684 008 5.645 008 5.368 008 4.118 008 6.00+003 1.325 007 1.003-007 9.198-008 5.780 008 6.167 008 5.193 008 4.962-008 4.544-008 3.772 008 6.44+003 1.207 007 9.154-008 8.403 008 5.287-008 5.638-008 4.731-008 7.24+003 1.032 007 7.861 008 7.221 008 4.554-008 4.851 008 4.048-008 3.919 008 3.253 008 7.50+003 9.856 008 7.513 008 6.902 008 4.356 008 4.640-008 3.864-008 3.750 008 3.112 008 8.05+003 8.979 008 6.859 008 6.303 008 3.984-008 4.241-008 3.520-008 3.431-008 2.847 008 8.50+003 8.350 008 6.390 008 5.873-008 3.716-008 3.955-008 3.273 008 3.201-008 2.656-008 O 9.00+003 7.742 008 5.925-008 5.455 008 3.455-008 3.677-008 3.034 008 2.976-008 2.470 008 I i 9.50+003 7.209 008 5.534-008 5.087 008 3.226-008 3.432-008 2.824-008 2.778-008 008 2.308 2.160 008 \j 1.00+004 6.737 008 5.179 008 4.761 008 3.022-008 3.2)5-008 2.638 008 2.603 008 1.21+004 5.257 008 4.062-008 3,733 008 2.378-008 2.530-008 2.055-008 2.046 008 1.699 008 '
4.326 008 3.355-008 3.082 008 1.969 008 2.095 008 1.688-008 1.691 008 1.405 008 1.40+004 l 1.414 008 1.176 008 3.604 008 2.805-008 2.575-008 1.649 008 1.755 008 1.404-008 ) I I 1.61+004 008 1.225 008 1.019 008 3.113 008 2.429 008 2.229 008 1.430 008 1.523-008 1.211 i 1.80+004 2.00+004 2.713 008 2.122-008 1.946-008 1.251 008 1.333 008 1.054 008 1.070 008 8.901 009 2.20+004 2.396 008 1.878 008 1.722 008 1.109-008 1.182 008 9.295-009 9.463-009 7.879 009 2.41+004 2.124 008 1.668-008 1.528 008 9.853 009 1.051 008 8.227-009 8.400-009 6.997 009 2.60+004 1.928 008 1.517 008 1.390 008 8.968 009 9.573-009 7.464 009 7.637-009 6.364-009 1.264 008 8.'64 009 8.720-009 6.773 009 6.945-009 5.790*009 j 2.80+004 1.752 008 1.380 008 1.462 008 1.156-008 1.058-008 6,843 009 7.318-C09 5.644-009 5.810-009 4.847 009 1 3.22+004 I 3.40+004 1.362 006 1.078 008 9.864 009 6.385-009 6.831 009 5.254 009 5.416 009 4.521 009 I 4.02+004 1.096 008 8.703 009 7.963 009 5.161-009 5.532-009 4.221-009 4.369-009 3.650 009 4.20+004 1.038 008 8.242 009 7.542 009 4.890-009 5.243-009 3.993-009 4.137-009 3.457 009 j 4.83+004 8.678 009 6.911-009 6.326-009 4.103 009 4.406 009 3.337 009 3.466 009 2.899-009 5.00+004 8.297-009 6.612-009 6.053-009 3.927 009 4.218-009 3.190-009 3.316 009 2.774-009 5.63+004 7.124 009 5.689-009 5.209 009 3.381-009 3.636 009 2.737 009 2.852 009 2.388 009
' 5.80+004 6.862 009 5.483 009 5.021-009 3.259 009 3.506 009 2.636-009 2.748 009 2.301-009 6.00+004 6.571 009 5.254 009 4.812-009 3.123 009 3.361 009 2.524-009 2.633-009 2.205-009 6.44+004 6.007 009 4.808-009 4.405 009 2.859 009 3.079-009 2.306-009 2.409-009 2.018-009 7.24+004 5.169 009 4.145-009 3.799 009 2.466-009 2.660-009 1.984-009 2.076-009 1.741 009 4.943 009 3.967 009 3.636 009 2.360-009 2.547-009 1.897-009 1.986-009 1.666-009 7.50+004 1.817-009 1.525-009 8.056004 4.520 009 3.631-009 3.330 009 2.161-009 2.334-009 1.734-009 009 1.696 009 1.424-009 8.50+004 4.215 009 3.389-009 3.109-009 2.018 009 2.180 009 1.617 1.578-009 1.325 009 9.00+004 3.920 009 3.154-009 2.894 009 1.878 009 2.031 009 1.503-009 009 1.474-009 1.238-009 i
9.50+004 3.659 009 2.947 009 2.705 009 1.755 009 1.899-009 1.403 3.428-009 2.763-009 2.537 009 1.646 009 1.782 009 1.314-009 1.382-009 1.161-009 2 1.00+005 f ( o CLINTON-1 7-7 Rev.2-10/86 L_________.______
4 i CPS-0DCM g Table 7.2-1 (Continued) Q ANNUAL AVERAGE MIXED-MODE X/Q April 1975 - April 1976 Distance Sector (meter) 5 SSW SW WSW W WNW NW NNW i.00+002 2.190-005 1.673 005 3.393-005 3.522 005 3.390-005 2.578-005 3.755-005 5.162-005 1.10+002 1.833 005 1.399 005 2.838-005 2.947 005 2.836-005 2.156-005 3.142-005 4.315-005 1.20+002 1.560 005 1.190 005 .2.414 005 2.507-005 2.411 005 1.834 005 2.673-005 3.668 005 i 1.30+002 1.345-005 1.026 005 2.081-005 2.162 005 2.079-005 1.581-005 2.305-005 3.161-005 1,40+002 1.174-005 8.945-006 1.815-005 1.887 005 1.813 005 1.379 005 2.011 005 2.756-005 1.50+002 1.035 005 '.882-006 1.600 005 1.663 005 1.598 005 1.216-005 1.772 005 2.429-005 1.60+002 9.203-006 , 006-006 1.423-005 1.478 005 1.421 005 1.081-005 1.576 005 2.159-005
- g. 1.411-005 1.933-005 1.70+002 8.245-006 6.275 006 1.274-005 1.324-005 1.272 005 9.685-006 t 80+002 7.434-006 5.656-006 1.149-005 f.193 005 1.147 005 8./34 006 1.272-005 1.743 005 1.90+002 6.743 006 5.129 006 1.042 005 1.082-005 1.040-005 7.922-006 1.154-005 1.580-005 2.00+002
- 6.147-006 4.675 006 9.503 006 9.862-006 9.480 006 7.224-006 1.051 005 1.440-005 2.10+002 5.630-006 4.281 006 8.704 006 9.032 006 8.681-006 6.618-006 9.628 006 1.319 005 2.20+002 5.178-006 3.937-006 8.006-006 8.306 006 7.984 006 6.088-006 8.854-006 1.213 005 2.3O+002 4.781 006 3.635 006 7.393-006 7.669-006 7.371-006 5.623 006 8.174 006 1.120-005 2.40+002 4.430-006 3.368 006 6.850 006 7.105 006 6.829 006 5.211-006 7 572-006 1.038 005 2.50+002 4.119-006 3.132 006 6.370 006 6.606-006 6.349-006 4.846-006 7.038-006 9.648 006 2.60+002 3.850-006 2.932-006 5.957-006 6.169 006 5.933 006 4.529 006 6.573-006 9.016-006 2.70+002 3.608-006 2.751 006 5.585-006 5.777-006 5.559-006 4.243-006 6.155-006 8.449-006 2.80+002 3.389-006 2.587 006 5.248 006 5.423-006 5.221-006 3.985-006 5.777 006 7.936*006 2.90+002 3.191-006 2.439 006 4.943 006 5.102-006 4.915-006 3.752-006 5.435 006 7.471-006 m 3.00+002 3.010 006 2.305-006 4.666 006 4.810-006 4.637 006 3.539 006 5.124-006 7.048-006
[ j 3.20+002 2.695 006 2.069 006 4.179 006 4.301-006 4.150 006 3.168 006 4.580 006 6.309 006 y/ 3.40+002 2.429-006 1.870 006 3.769-006 3.872-006 3.740 006 2.855-006 4.123 006 5.685 006 3.60+002 2.202 006 1.701 006 3.419-006 3.508 006 3.391-006 2.589-006 3.734 006 5.155 006
# 3.80+002 2.010 006 1.557 006 3.121 006 3.197 006 3.095-006 2.364-006 3.405-006 4.707 006 ' 4.00+002 1.84P OO6 1.437 006 2.868-006 2.935 006 2.847 006 2.177-006 3.128 006 4.337 006 4.20+002 1.705 006 1.331 006 2.647-006 2.706 006 2.629-006 2.012-006 2.886-006 4.011-006 4.40+002 1.580-006 1.237 006 2.452 006 2.504-006 2.437 006 1.867-006 2.672 006 3.723-006 4.60+002 1.469 006 1.154-006 2.278-006 2.325-006 2.266 006 1.738-006 2.483-006 3.467-006 4.80+002 1.369-006 1.079 006 2.124*006 2.165 006 2.114-006 1.622-006 2.315-006 3.238-006 5.00+002 1.281-006 1.012 006 1.985 006 2.022 006 1.978 006 1.518-006 2.164-006 3.032.*006 5.20+002 1.201-006 9.520-007 1.860-006 1.894 006 1.855 006 1.425-006 2.028 006 2.848 006 5.40+002 1.128-006 8.972 007 1.748 006 1.778 006 1.744-006 1.341-006 1.905-006 2.680 006 5.60+002 1.063 006 8.474 007 1.646 006 1.673-006 1.644-006 1.264-006 1.794-006 2.52b OO6 5.80+002 1.003-006 8.018 007 1.553-006 1.577 006 1.552 006 1.194 006 1.693-006 2.388 006 6.00+002 9.488-007 7.601 007 1.468-006 f.490 006 1.468 006 1.130-006 1.600-006 2.261-006 6.50+002 8.318-007 6.698-007 1.285-006 1.003 006 1.287-006 9.922 007 1.402 006 1.986 006 l
7.00+002 7.378 007 5.965 007 1.139 006 1.154 006 1.142 006 8.816-007 1.243-006 1.765 006 7.50+002 6.622-007 5.372-007 1.021-006 1.037 006 1.026-006 7.932 007 1.115-006 1.587-006
' 8.05+002 5.932 007 4.825 007 9.140 007 9.295-007 9.193 007 7.120-007 9.987-007 1.424-006 8.50+002 5.445-007 4.438-007 8.384-007 8.536 007 8.439 007 6.546 007 9.163-007 1.309-006 9.00+002 4.981 007 4.067-007 7.662 007 7.811-007 7.717-007 5.996-007 8.375 007 1.198 006 9.50+002 4.580-007 3.745 007 7.037 007 7.182-007 7.091 007 5.518-007 7.6"2 007 1.10f-006 1.00+003 4.247 007 3.476 007 6.515 007 6.658 007 6.567-007 5.119 007 7.124 007 1.021-006 1.10+003 3.660-007 3.003 007 5.603-007 5.734-007 5.646*007 4.414 007 6.119-007 8.786-007 3.203-007 2.633 007 4.894 007 5.015-007 4.928 007 3.863-007 5.337 007 7.676-007 1.20+003 1.3O+003 2.840-007 2.338-007 4.331-007 4.443-007 4.357-007 3.423 007 4.715 007 6.789 007 1.40+003 2.564 007 2.109 007 3.901-007 4.007-007 3.918 007 3.083-007 4.241-007 6.101 007 1.50+003 2.347-007 1.928-007 3.564-007 3.665 007 3.574-007 2.814-007 3.871-007 5.553-007 1.61+003 2.148-007 1.761 007 3.253-007 3.349-007 3.256-007 2.565-007 3.529 007 5.049-007 7-8 Rev.2-10/86 Q CLINTON-I
l CPS-0DCM () L ,i Tab'le 7.2-1 (Continued) ANNUAL AVERAGE MIXED-MODE X/Q ; April 1975 - April 1976 ' I Distance Sector _( meter) S SSW SW WSW W WNW NW NNW j 1.80+003 1.867 007 1.529-007 2.816-007 2.903 007 2.810-007 2.217 007 3.049-007 4.343-007 2.00+003 1.638-007 1.342 007 2.462-007 2.541-007 2.449-007 1.935-007 2.660 007 3.774-007 2.20+003 1.457-007 1.195-007 2.182-007 2.254-007 2.165-007 1.713 007 2.353-007 3.327 007 2.41+003 1.301-007 1.068-007 1.941 007 2.006-007. 1.922-007 1.522-007 2.090-007 2.944-007 2.60+003 1.188-007 9.776 008 1.769-007 1.828-007 1.748-007 1.385-007 1.902 007 2.671 007 I i 2.80+003 1.086 007 8.952 008 1.612 007 1.666 007 1.590-007 1.262 007 1.731-007 2.425-007 3.00+003 9.980 008 8.248-008 1.478-007 1.528-007 1.457-007
)
1.157-007 1.587-007 2.216-007 l 3.22+003 9.158-008 7.589 008 1.353-007 1.399-007 1.332 007 1.059-007 1.452-007 2.023 007 3.60+003 7.986-008 6.648-008 1.176 007 1.216 007 1.156-007 9.198 008 1.261-007 1.749 007 4.02+003 6.970 008 5.834-008 1.023-007 1.058-007 1.005 007 8.003-008 1.097-007 1.515-007 4.40+003 6.243 008 5.247-008 9.145 008 9.452-008 8.978-008 7.154*008 9.801 008 1.349-007 4.83+003 5.566 008 4.696-008 8.135-008 8.407 008 7.984-008 6.368-008 8.721-008 1.197 007 5.00+003 5.329-008 4.503 008 7.783 008 8.043-008 7.638 008 6.094-008 8.345-008 1.144-007 5.20+003 5.075 008 4.295 008 7.407 008 7.653-008 7.267-008 5.801-008 7.943-008 1.087-007 5.63+003 4.593 008 3.899 008 6.693 008 6.916-008 6.567-008 5.246-008 7.181-008 9.802-008 i 6.00+003 4.244-008 3.610-008 6.178 008 6.382-008 6.061 008 4.840-008 6.631-008 9.032-008 t 6.44+003 3.885 008 3.312 008 5.649 008 5.836-008 5.542-008 4.433-008 6.068-008 8.245-008 7.24+003 3.348-008 2.864 008 4.861 008 5.022-008 4.771 008 3.821-008 5.228 008 7.078-008 ' l 7.50+003 3.203-008 2.743-008 4.648 008 4.802 008 4.563 008 3.656 008 5.002 008 6.764-008 ' 8.05+003 2.930 008 2.513 008 4.248 008 4.389 008 4.171-CX;U 3.345-008 4.576-008 6.175-008 8.50+003 l' 9.00+003 2.733 008 2.347 008 3.960 008 4.092 008 3.889-008 3.121-008 4.269-008 5.751-008 l 2.542-008 2.18$-008 3.680*008 3.803-008 3.616-008 2.903-008 3.971 008 5.341 008 [O} V 9.50+003 1.00+004 2.373 008 2.042-008 3.433 008 3.549-008 3.374-008 2.711 008 3.708 008 4.980-008 2.223 Od8 1.915-008 3.214-008 3.323-008 3.160-008 2.541-008 3.475 008 4.660-008 I i 1.21+004 1.748 008 1.510-008 2.523 008 2.611-008 2.485-008 2.003 008 2.738 008 3.653 008 I 1.40+004 1.446-008 1.251-008 2.084-008 2,160-008 2.056-008 1.660-008 2.270 008 3.016 008 : 1.61+004 1.211-008 1.048 008 1.741-008 1.807-008 1.720-008 1.392-008 1.80+004 1.903-008 2.520 008 1.049 008 9.090-009 1.507 008 1,566-008 1.491 008 1.209-008 1.652 008 2.182-008 2.00+004 9.172-009 7.948-009 1 1.316 008 1,370-008 1.303-008 1.059-008 1.446 008 1.906 008 2.20+004 8.122-009 7.039 009 1.164 006 1.213-008 1.154 008 9.390 009 1.282 008 1.687-008 2.41+004 7.216-009 6.254-009 1.033 008 1,079-008 1.025-008 8.355-009 1.140 008 2.60+004 1.498-008 2.80+004 6.566-009 5.690 009 9.384 009 9.817-009 9.327-009 7.612 009 1.039 008 1.362-008 5.975 009 5.177-009 8.530 00* 8.939 009 8.487 009 6.936-009 9.461 009 1.239-008 3.22+004 5.006-009 4.336-009 7.131*009 7.497-009 7.109-009 5.824-009 7.940-009 1.038 008 3.40+004 4.670 009 4.044 009 6.646 009 6.998-009 6.631 009 5.438-009 7.412 009 9.681 009 4.02+004 3.773-009 3.265-009 5.355 009 5.664-009 5.356-009 4.407-009 6.000 009 7.820-009 4.20+004 l 4.83+004 3.575-009 3.092-009 5.069-009 5.368-009 5.072 009 4.178-009 5.686-009 7.4C7-OO9 5.00+004 3.000-009 2.592-001 4.243-009 4.511-009 4.253-009 3.514-009 4.776-009 6.214 009 2.871-009 2.480 009 4.058-009 4.318-009 4.069-009 3.366-009 4.572-009 5.946-009 5.63+004 5.80+004 2.472 009 2.133 009 3.486-009 3.723 009 3.501 009 2.902-009 3.940-009 5.119-009 2.383 009 2.056 009 3.359 009 3.590-009 3.374*009 2.799-009 3.798-009 4.934-009 6.00+004 2.284 009 1.970-009 3.217-009 3.442 009 3.233-009 2.684-009 3.641-009 6.44+004 2.091-009 1.803 009 2.941-009 3.154-009 2.959-009 2.460-009 3.335-009 4.329-009 4.729-009 7.24+004 1.804-009 1.554 009 2.532-009 2.726 009 2.551 009 2.126-009 2.879-009 3.735-009 7.50+004 1.727-009 1.487-009 2.422-009 2.610 009 2.441 009 2.036-009 2.756-009 3.575-009 8.05+004 1.581 009 1.361-009 2.215-009 2.393 009 2.234-009 1.866-009 2.525-009 ,3.274-009 8.50+004 1.477-009 1.270 009 2.066-009 2.236-009 2.086 009 1.744-009 2.358 009 3.057 009 9.00+004 1.375-009 1.182 009 1.922-009 2.084 009 1.941-009 1.625-009 2.196-009 2.846-009 9.50+004 1.285-009 1.104-009 1.794-009 1.949 009 1.814-009 1.520-009 2.053 009 2.660-009 1.00+005 1.205-009 1.035-009 1.682-009 1.830 009 1.701-009 1.426-009 1.926-009 2.495-009 r ( CLINTON-I 7-9 Rev.2-10/86 L
l l CPS-0DCM 1 Table 7.2-2
\s)
ANNUAL AVERAGE MIXED-MODE D/Q
- April 1975 - April 1976 Distance Sector ;
(meter) _,, N NNE NE ENE E ESE SE SSE 1.00+002 2.908 007 2.224 007 1.887-007 1.152-007 1.418 007 1.524 007 1.002-007 7.533 008 1.10+002 2.562 007 1.960-007 1.663-007 1.015 007 1.250-007 1.343-007 8.837-008 6.641-008 1.20+002 2.283-007 1.746-007 1.482-007 9.049-008 1.113-007 1.197-007 7.876-008 5.920-008 1.30+002 2.053 007 1.571-007 1.334-007 8.141-008 1.001-007 1.076 007 7.087-008 5.327-008 1.40+002- 1.861 007 1.424-007 1.210 007 7.383-008 9.078 008 9.759 008 6.428-008 4.832-008 1.50+002 1.699 007 1.300-007 1.105-001' 6.742-008 8.286 008 8.908-008 5.871-008 4 414 008 1.60+002 1.560 007 1.194-007 1.015-007 6.194-008 7.610-008 8.181-008 5.395-008 4.057-008 i 1.70+002 1.440 007 1.102-007 9.380-008 5.721 008 7.025-008 7.553-008 4.984-008 3.749-003 1 1.80+002 1.335 007 1.022-007 8.707-008 5.310-008 6.516 008 7.007-008 4.627-008 3.481-008 1.90+002 1.244-007 9.522-008 8.118-008 4.949 008 6.070-008 6.527-008 4.314-008 3.246-008 2.00+002 1.163 007 8.906 008 7.600 008 4.632 008 5.677-008 6.105-008 4.040-008 3.041 008 2.10+002 1.085 007 8.314 008 7.101-008 4.326-008 5.299-008 5.699-008 3.775-008 2.843-008 2.20+002 1.016 007 7.s86-OO8 6.657-008 4.055-008 4.963 008 5.338 008 3.539-008 2.666-008 2.3O+002 9.547 008 7.315 008 6.260 008 3.812 008 4.663-008 5.015 008 3.329 008 2.509-008 2.40+002 8.992 008 6.892-008 5.904 008, 3.594-008 4.393 008 4.725 008 3.140-008 2.367-008 2.50+002 8.491-008 6.510-008 5.583-008 3.397-008 4.149-008 4.463 000 2.969-008 2.240-008 2.60+002 8.037 008 6.163-008 5.292 008 3.219 008 3.928-008 4.226 008 2.815-008 2.125-008 2.70+002 7.625-008 5.849-008 5.028 008 3.057 008 3.727-008 4.011-008 2.675 008 2.020-008 2.80+002 7.248 008 5.562 008 4.788 008 2.910 008 3.544 008 3.814 008 2.548-008 1.925-008 2.90+002 6.903 008 5.299 008 4.568-008 2.775-008 3.377-008 3.634-008 2.422 008 1.838 008 I 3.00+002 6.587 008 5.058-008 4.367 008 2.651-008 3.223-008 3.469 008 2.325 008 1.759 008 I f3 3.20+002 5.988-008 4.601-008 3.979-008 2.415-008 2.931 008 3.156 008 2.120-008 1.605-008 3.40+002 5.477 008 4.210-008 3.649 008 2.213 008 2.682-008 2.888-008 1.945 008 1.474 008
\ 3.60+002 5.036-008 3.873-008 3.365-008 2.039-008 2.468*008 2.658-008 1.795 008 1.362-008 3.80+002 4.653-008 3.581 008 3.118 008 1.488-008 2.281-008 2.458 008 1.664-008 1.264 008 4.00+002 4.318-008 3.325-008 2.902-008 1.756 008 2.118-008 2.283 008 1.550-008 1.179 008 4.20+002 4.022 008 3.100 008 2.712 008 1.640 008 1.975 008 2.128-008 1.450 008 1.104-008 4.40+002 3.761-008 2.901-008 2.544-008 1.537-008 1.848 008 1.992-008 1.361 008 1.038-00R 4.60+002 3.528 008 2.723 008 2.394-008 1.446-008 1.735 008 1.870-008 1.282-008 9.794-009 4.80+002 3.319-008 2.564 008 2.260-008 1.364-008 1.633 008 1.763 C08 1.212-008 9.271-009 5.00+002 J.131-008 2.422-008 2.140-008 1.290 008 1.542-008 1.664-008 1.149-008 8.803 009 5.20+002 2.948 008 2.281-008 2.018 008 1.216 008 1.453-008 1.568 008 1.085-008 8.318-009 5.40+002 2.782-008 2.153 008 1.908-008 1.150 008 1.372 008 1.481 008 1.027-008 7.879-009 5.60+002 2.630-008 2.038 008 1.808 008 1.089-008 1.298-008 1.401-008 9.737-009 7.480-009 5.80+002 2.493-008 1.932-008 1.716 008 1.033 008 1.231-008 1.329-008 9.256-009 7.116-009 6.00+002 2.367-008 1.835-008 1.633 008 0.826-009 1.169-008 1.263-008 8.815 009 6.783-009 6.50+002 2.094 008 1.62' 008 1.452-008 8.731 009 1.037-008 1.120 008 7.867-009 6.066-009 j 7.00+002 1.872 008 1.456 006 1.304 000 7.833-009 9.279-009 1.004-008 7.091-009 5.480-009 7.50+002 1.683 008 1.311-008 1.176-008 7.063 009 8.350 009 9.045-009 6.418-009 4.969-009 8.05+002 1.510-008 1.178 008 1.060*008 6.359-009 7.514 009 8.138 009 5.805-009 4.503-009 8.50+002 1.389-008 1.085-008 9.776-009 5.864-009 6.920-009 7.500-009 5.374-009 4.175-009 9.00+002 1.273*008 9.958 009 8.992-009 5.391-009 6.354 009 6.891-009 4.963 009 3.862-009 9.50+002 1.173 008 9.188 009 8.313 009 4.981-009 5.865-009 6.365-009 4.608-009 3.593 009 1.00+003 1.085-008 8.516-009 7.721 009 4.625-009 5.438-009 5.907-009 4.299-009 3.358-009 1.10+003 9.263 009 7.283 009 6.616 009 3.962-009 4.654 009 5.060-009 3.705-009 2.900-009 1.20+003 8.021-009 6.319 009 5.751 009 3.443-009 4.0402009 4.397-009 3.239-009 2.540-009 1.3O+003 7.030-009 5.548 009 5.059-009 3.028-009 3.550-009 3.867-009 2.867-009 2.253 009 1.40+003 6.224 009 4.922 009 4.497 009 2.691-009 3.152-009 3.437-009 2.564-009 2.019-009 1.50+003 5.559-009 4.406 009 4.033 009 2.414-009 2.823-009 3.082-009 2.314 009 1.826 009 1.61+003 4.957 009 3.938 009 3.613-009 2.162 009 2.526-009 2.761-009 2.088-009 1.651-009 **i.908 x 10-7 ,-2 (m) CLINTON-I 7-10 Rev.2-10/86 N.)
CPS-0DC24
<--i ,
(s_ /I Table.7.2-2 (Continued) ANNUAL AVERAGE MIXED-MODE D/Q , i April 1975 - April 1976 Distance Sector (nuater) i l NE ENE E E S.E SE SSE N NNE 4.136*009 3.300 009 3.038 009 1,818 009 2.119-009 2.322 009 1.778-009 1.413-009 1.80+003 1.537-009 1.226 009 2.00+003 3.493 009 2.801 009 2.589 009 1.549-009 1.802-009 1.979-009 1.057-009 2.20+003 2.970 009 2.387-009 2.211 009 1.323-009 1.537 009 1.691 009 f.322 009 009 f.143 009 9.160 010 2.41+003 2.537 009 2.045 009 1.897-009 1.135-009 1.318-009 1.452 2.60+003 2.238 009 1.807*009 1.680-009 1.005 009 1.166 009 1.286-009 1.018-009 8.177-010 1.975 009 1.599-009 1.488-009 8.909 010 1.032 009 1.140-009 9.083-010 7.308 010 2.80+003
.3.00+003 1.758 009 1.427-009 1.330 009 7.965-010 9.219-010 1.019-009 8.172 010 6.588-010 1 . 3.22+003 1.561-009 1,268 009 1.184 009 7.089-010 8.199-010 9.071-010 7.296 010 5.889-010 j 3.60+003 1.292 009 1.052 009 9.837 010 5.892 010 6.805 010 7.538 010 6.095-010 4.930 010 l 4.02+003 1.071 009 8.740-010 8.189 010 4.906 010 5.658-010 6.275-010 5.101 010 4.135-010 4.40+003' 9.215 010 7.532-010 7.068 010 4.235 010 4.879-010 5.416-010 4.423-010 3.592-010 4.83+003 7.884-010 6,456 010 6.069 010 3.637-010 4.185-010 4.650-010 3.816-010 3.105-010 7.434 010 6.092 010 5.730 010 3.434-010 3.950-010 4.391-010 3.610 010 2.940-010
- 5. 00+003 6.20+003 6.938 010 5.689 010 5.354 010 3.209-010 3.689 010 4.102 010 3.377-010 2.752 010 5.63+003 6.027-010 4.948-010 4.663 010 2.794-010 3.209 010 3.571-010 2.940-010 2.404-010 6.00+003 5.393 010 4.431-010 4.180 010 2.505 010 2.875-010 3.200-010 2.648-010 2.161-010 6.44+003 4.765-010 3.919-010 3.702 010 2.218-010 2.543-010 2.832-010 2.350-010 1.920 010 7.24+003 3.882-010 3.197-010 3.025-010 1.812-010 2.075 010 2.313 010 1.925 010 1.574-010 7.50+003 3.658 010 3.013-010 2.852-010 1.708-010 1.956-010 2.180 010 1.815-010 1.485 0f0 8.05*003 3.247-010 2.675 010 2.533 010 1.517-010 1.736 010 1.935 010 1.612-010 1.319-010 8.50+003 2.959 010 2.438-010 2.309 010 1.383-010 1.582 010 1.764-010 1.469-010 1.203-010 2.686 010 2.214-010 2.098 010 1.256-010 1.437-010 1.601-010 1.334-010 1.093-010 9.00+003 1.461-010
(* i 9.50+003 1.00+004 2.451 010 2.020 010 1.915 010 1.147-010 1.311-010 1.218-010 9.981 011 2.247 010 1.852-010 1.757 010 1.052 010 1.202 010 1.340-010 1.117-010 9.158-011 l 1.21+004 1,645-010 1.356 010 1.288 010 7.708 011 8.795 011 9.804-011 8.180 011 6.712 011 1.40+004 1.286-010 1.060-010 1.008 010 6.034 011 6.876 011 7.665-011 6.398 011 5.254-011
' 1.61+004 1.020-010 8.415-011 8.013 011 4.794-011 5.457-011 6.083-011 5.080-011 4.175-011 1.80+004 8.475-011 6.990-011 6.663 011 3.985 011 4.532 011 5.052-011 4.221-011 3.471 011 2.00+004 7.117-011 5.871 011 5.601 011 3.350-011 3.805 011 4.242-011 3.546-011 2.918-011 2.20+004 6.043 C11 4.987-011 4.767 011 2.849 011 3.231 011 3.603 011 3.015 011 2.483 011 2.41+004 5.154 011 4.254-011 4.075 011 2.434-011 2.755 011 3.073 011 2.574-011 2.122-011 2.60+004 4.538 011 3.747 011 3.595 011 2.147-011 2.427 011 2.706-011 2.269-011 1.872 011 2.80+004 3.997-011 3.302-011 3.173 011 1.894-011 2.138 011 2.384-011 2.001-011 1.653+011 3.22+004 3.*44-011 2.600 011 2.508 011 1.496 011 1.683-011 1.876-011 1.580-011 1.306-011 3.40+004 2.858 011 2.366 011 2.286-011 1.362-011 1.530-011 1.706-011 1.439 011 1.191-011 4.02+004 2.t36-011 1.772-o*1 1.722 011 1.025 011 1.145 011 1.277-011 1.083 011 8.986-012 4.20+004 1.983-011 1.647 vit 1.603-011 9.533-012 1.064-011 1.186-011 1.007-011 8.366-012 4.83+004 1.564-011 1.303-011 1.274 011 7.564 012 8.399-012 9.352-012 7.985-012 6.648 012 l 5.00+004 1.474 011 1.230 011 *1.203 011 7.143-012 7.921-012 8.815-012 7.537 012 6.279-012 l
5.63+004 1.194 011 9.999-012 9.629 012 5.828-012 6.,428 012 7.145 012 6.149-012 5.137-012 5.80+004 1.134-011 9.510-012 9.358 012 5.547-012 6.109 012 6.788-012 5.851-012 4.892-012 !' 6.00+004 1.069-011 8.977 012 8.843 012 5.241-012 5.762 012 6.398-012 5.526-012 4.624-012 6.44+004 9.462 012 7.975 012 7.875-012 4.663 012 5.108 012 5.662 012 4.911 012 4.118-012 7.24+004 7.704-012 6.534-012 6.466-012 3.827-012 4.167-012 4.604-012 4.019-012 '3.181-012 7.50+004 7.223-012 6.136 012 6.069-012 3.593 012 3.909 012 4.315 012 3.771-012 3.176-012 8.05+004 3.321-012 2.802-012 6.351-012 5.414-012 5.351 012 3.169-012 3.441-012 3.791-012 3.010-012 8.50+004 5.750 012 4.918 012 4.856 012 2.877-012 3.119 012 3.429-012 2.544-012 9.00+004 5.190-012 4.453-012 4.394 012 2.604-012 2.817-012 3.091-012 2.719 012 2.303-012 l 9.50+004 4.714 012 4.060 012 4.003-012 2.372 012 2.562 012 2.803-012 2.472 012 2.097-012 l 1.00+005 4.308-012 3.724 012 3.668 012 2.175-012 2.343-012 2.557-012 2.261-012 1.921-012 1 1 i CLINTON.I 7-11 Rev.2 10/86 l o} v 1
CPS-0DCM i Table 7.2-2 (Continued) ANNUAL AVERAGE MIXED-hol)E D/Q April 1975 - April 1976 Distance Sector (meter) S SSW SW WSW W WNW NW NNW 1.00+002 6.278 006 5.487-006 9.005-008 6.174-008 6.643-008 6.293 008 7.809-008 1.473 007 1.10+002 5.533-008 4.838-008 7.937 008 5.443-008 5.856 008 5.548 008 6.882-008 1.298 007 1.20+002 4.930 008 4.313 008 7.073-008 4.852-000 5.221-008 4.946 008 6.132 008 1.040 1.157-007 1.3O+002 4.435 008 3.882-008 6.363 008 4.366 008 4.698 008 4.452-008 5.515 008 007 1.40+002 4.021 008 3.523 008 5.771-008 3.960-008 4.262-008 4.039 008 5.000-008 9.430-008 1.50+002 3.671 008 3.219 008 5.270 008 3.617-008 3.893-008 3.690 008 4.564 008 8.608 008 1.60+002 3.372-008 2.960-008 4.841-008 3.324 008 3.579-008 3.393 008 4.192 008 7.905-008 i 3.114 008 2.737-008 4.472-008 3.072 008 3.307-008 3.136 008 3.870-008 7.298 008 1.70+002 l 1.80+002 2.890 008 2.542 008 4.150-008 2.852 008 3.071 008 2.913-008 3.591 008 6.709-008 ! 1.90+002 2.693-008 2.372-008 3.868 008 2.659-008 2.864-008 2.717-008 3.345-008 6.306-008 2.520-008 2.224-008 3.620 008 2.490-008 2.682-008 2.546-008 3.129 008 5.898 008 i 2.00+002 2.104002 2.353-008 2.000-008 3.381-008 2.327 008 2.507 008 2.380-008 2.921 008 5.505-008 ; 2.20+002 2.205 008 t.952 008 3.169 008 2.182-008 2.351-008 2.233-008 2.736 008 5.156-008 2.3O+002 2.072-008 1.837-008 2.979-008 2.052 008 2.212 008 2.101-008 2.571-008 4.844 008 i 2.40+002 1.953 008 1.735-008 2.808 008 1.936-008 2.087-008 1.983-008 2.422-008 4.564-008 ) 1.846 008 1.643 008 2.654-008 1.831 000 1.974 008 1.877-008 2.288-008 4.310-008 2.50+002 2.60+002 1.749 005 1.559 008 2.515-008 1.736-008 1.872-008 1.781-008 2.167 008 4.081-008 ' 2.70+002 1.661-008 1.484 008 2.389-008 1.650 008 1.780-008 1.694 008 2.056 008 3.873 008 2.80+002 1.580 008 1.415 008 2.273 006 1.571-008 1.696 008 1.615-008 1.956-008 3.683-008 2.90+002 1.506-008 1.352-008 2.168 008 1.500 008 1.619 008 1.542-008 1.863-008 3.509-008 3.00+002 1.439 008 1.295 008 2.071-008 1.434 008 1.549-008 1.476-008 1.779 008 3.349 008 3.20+002 1.310 008 1.183-008 1.887-008 1.307 008 1.413-008 1.347-008 1.618 008 3.046 008 O 1.729 008 1.199 008 1.296-008 1.238 008 1.481 008 2.788-008 3.40+002 1.201 008 1.088-008 i ( V) 3.60+002 3.80+002 1.106-008 1.006-008 1.024-008 9.349 009 1.593-008 1.475-008 1.107-008 1.026-008 1.197 008 1.110-008 1.143-008 1.062-000 1.363-008 1.261 008 2.565 008 2.372 008 t 4.00+002 9.523 009 8.729-009 1.372-008 9.554 009 1.034 008 9.901 009 1.171 008 2.202-008 4.20+002 8.892 009 8.184 009 1.281 008 8.934-000 9.676 009 9.272 009 1.092 008 2.053 008 4.40+002 8.334 009 7.703 009 1.200-008 8.386 009 9.086-009 8.716 009 1.022-008 1.921 008 4.60+002 7.837-009 7.275 009 1.129-008 7.899-009 8.562 009 8.223-009 9.597-009 1.804-008 4.80+002 7.394-009 6.894 009 1.065-008 7.464-009 8.094-009 7.782-009 9.039-009 1.099 008 5.00+002 6.996 009 6.553 009 1.00t-008 7.073-009 7.675-009 7.386 009 8.539-009 1.604 008 5.20+002 6.598-009 6.193 009 9.500 009 6.676-009 7.244-009 6.975-009 8.044-009 1. 51 L.OO8 5.40+002 6.237 009 5.866 009 8.978-009 6.316-009 6.853 009 6.603 009 7.596-009 1.426-008 5.60+002 5.909 009 5.570 009 8.504-009 5.989-009 6.499 009 6.264-009 7.189 009 1.350-008 5.80+002 5.611-009 5.299 009 8.072-009 5.691 009 0.175 009 5.955 009 6.818-009 1.280-008 6.00+002 5.338-009 5.051 009 7.677 009 5.418 009 5.879-009 5.672 009 6.479 009 1.216-008 6.50+002 4.749 009 4.516 009 6.824 009 4.831 009 5.239 009 5.062-009 5.747-009 1.078 008 l 7.00+002 4.268-009 4.078-009 6.126 0C3 4.350-009 4.716-009 4.561-009 5.147-009 9.644-C09 7.50+002 3.855 009 3.693 009 5.526 009 3.933-009 4.261-009 4.124-009 4.637 009 8.683-009
, 8.05+002 3.479-009 3.341-009 4.978-009 3.553 009 3.846 009 3.725-009 4.171*O09 7.805-009 ' 8.50+002 3.214-009 3.094-009 4.593 009 3.286-009 3.553-009 3.444-009 3.843-009 7.167-009 9.00+002 2.962-009 2.857-009 4.226-009 3.031-009 3.274 009 3.176-009 3.531-009 6.597-009 )
9.50+002 2.745-009 2.653 009 3.908-009 2.811-009 3.033-009 2.944 009 3.260-009 6.087-009 1.00+003 2.555 009 2.474 009 3.632-009 2.620-009 2.822-009 2.742-009 3.025-009 5.642 009 1.10+003 2.198-009 2.130-009 3.116 009 2.256-009 2.424 009 2.356-009 2.590-009 4.827-009 ) 1.20+003 1.918-009 1.860 009 2.712 009 1.971 009 2.112-009 2.054-009 2.251-009 4.189 009 1.3O+003 1.695-009 1.644-009 2.3b9 OO9 1.743-009 1.863-009 1.812-009 1.979-009 3.679-009 1.40+003 1.514-009 1.469 009 2.127 009 1.557-009 1.660-009 1.616 009 1.759-009 3.265-009 1.50+003 1.364-009 1.324 009 1.911 009 1.405 009 1.493 009 1.454-009 1.578-009 2.924-009 1.61+003 1.229 009 1.192-009 1.715-009 1.267-009 1.341-009 1.307-009 1.413-009 2.616 009 Os CLINTON-1 7-12 Rev.2-10/86 (v)
t l r,s CPS-0DCM Table 7.2-2 (Continued) ANNUAL AVERAGE MIXED-MODE D/Q April 1975 - April 1976 . Distance Sector (meter) ,, S SSW SW WSW W WNW NW NNW 1.80+003 1.045*009 1.013 009 1.448 009 1.078 009 1.134 009 1.107-009 1.189 009 2.195-009 2.00+003 9.014 010 8.731 010 1.240 009 9.312 010 9.728-010 9.506-010 1.014-009 1.866-009-2.20+003 7.748 010 7.494-010 1.062-009 8.010 010 8.333 010 8.146-010 8.666-010 1.592 009 2.41+003 6.'595 010 6.466 010 9.139 010 6.926 010 7.174 010 7.016-010 7.442-0f0 f.365-009 2.60+003 5.963 010 5.752-010 8.112-010 6.171-010 6.369 010 6.232 010 6.594 010 1.208 009 2.80+003 5.317-010 5.121-010 7.206 010 5.505-010 5.660-010 5.540-010 5.847 010 1.069 009 3.00+003 4.783 010 4.600-010 6.459-010 4.954 010 5.074 010 4.970 010 5.232 010 9.551-010
, 3.22+003 4.271-010 4.107-010 5.757 010 4.425-010 4.524 010 4.433-010 4.658 010 8.497-010 i 3.60+003 3.569 010 3.430 010 4.796 010 3.699 0f0 3.770 010 3.697 010 3.873 010 7.058 010 i 4.02+003 2.989 010 2.870 010 4.003 010 3.098 010 3.148 010 3.0t19-010 3.227 010 5.873 010 4.40+003 2.593 010 2.488 010 3.462-010 2.688 010 2.724-010 2.675-010 2.787-010 5.067 010 4.83+003 2.238-010 2.147-010 2.980 010 2.321 010 2.345-010 2.305 010 2.395 010 4.350 010 l 5.00+003 2.118 010 2.031-010 2.817-010 2.197-010 2.217 010 2.179-010 2.262 010 4.107 010 5.20+003 1.981 010 1.900 010'2.633-010 2.055 010 2.073-010 2.038 010 2.114 010 3.836 010 5.63+003 1.728 010 1.659 010 2.294 010 1.794-010 1.807 010 1.778 010 1.840 010 3.338 010 c 2.058 010 1.611*010 1.622-010 6.00+003 1.552-010 1.490 010 1.536 010 1.649 010 2.990-010 6.44+003 1.377-010 1.323 010 1.824 010 1.430 010 1.438 010 1.416 010 1.460 010 2.646 010 7.24+003 1.127 010 1.084 0f0 1.491-010 1.172 010 1.177 010 1.160 010 1.193 010 2.160 010 7.50+003 1.063 010 1.023 010 1.406 010 1.105 010 1.110 010 1.094-010 1.124-010 2.036 010 8.05+003 9.443-011 9.092-011 1.249 010 9.814 011 9.860 011 9.721-011 9.983 011 1.808 010 8.50+003 8.612 011 8.296 011 1.139 010 8.950 011 8.993 011 8.869 011 9.101-011 1.649-010 9.00+003 7.823 011 7.541 011 1.034 010 8.130 011 8.170 011 8.060 011 8.264 011 1.497 010 9.50+003 7.143 011 6.890 011 9.444-011 7.423 011 7.461 011 7.367 011 7.544-011 1.367-010 0 1.00+004 1.21+004 -1.40+004 1.61+004 6.553-011 6.324-011 4.801 011 4.646-011 3.757-011 3.643 011 2.985 011 2.900 011 8.663-011 e.810 011 6.846 011 6.757-011 6.918 011 6.348 011 4.969*011 1.254 010 4.991 011 5.021 011 4.962-011 5.066-011 9.184 011 3.908 011 3.934 011 3.890 011 3.963 011 7.186-011 3.948 011 3.105 011 3.128 011 3.095 011 3.947-011 5.708 011 J ; 1.80+004 2.481-011 2.414 011 3.282-011 2.581 011 2.602 011 2.576 011 '2.615 011 4.744 011 2.00+004 2.085-011 2.032-011 2.758 011 2.170 011 2.188 011 2.168 011 2.197-011 3.i#86-011 2.20+004 1.772-011 1.733 011 2.346 011 1.846 011 1.863 011 1.848 011 1.866 011 3.387-011 2.4t+004 1.513 011 1.484-011 2.004 011 1.577 011 1.594 011 1.582 011 1.593-011 2.891-011 2.60+004 1.333 011 1.311-011 1.767 011 1.391 011 1.407 011 1.398 011 1.403-011 2.548 011 2.80+004 1.175 011 1.159-011 1.558-011 1.227 011 1.242 011 1.235 011 1.236-011 2.241:011 3.22+004 9.273 012 9.200 012 1.230 011 9.698 012 9.834 012 9.795 012 9.748-012 1.770 011 3.40+004 8.444-012 8.401 012 1.120 011 8.839 012 8.969-012 8.941 012 8.872-012 1.610-011 4.02+004 6.343 012 6.365*012 8.411 012 6.659 012 6.774-012 6.770 012 6.659 012 1.207 011 1 4.20+004 5.899 012 5.933-012 7.822 012 6.198 012- 6.310 012 6.311 012 6.194 012 1.122-011 4.83+004 4.672 012 4.735 Ot2 6.191 012 4.926 012 5.029 012 5.043-012 4.917 012 8.877-012 j 5.00+004 4.410 012 4.478 012 5.841 012 4.655-012 4.756-012 4.772-012 4.647-012 8.378-012 5.63+004 3.595 012 3.677-012 4.755 012 3.809 012 3.900 012 3.924*012 3.797 012 6.815 012 5.80+004 3.421-012 3.505 012 4.522 012 3.828-012 3.717 012 3.742 012 3.616 012 6.482-012 . 6.00+004 3.231-012 3.317-012 4.268 012 3.431*012 3.518 012 3.544*012 3.419 012 6.118-012 6.44+004 2.872 012 2.961 012 3.788-012 3.059-012 3.142 012 3.171-012 3.050 012 5.434-012 7.24+004 2.354 012 2.441-012 3.093 012 2.518 012 2.594 012 2.626-012 2.521 012 4.452 012 7.50+004 2.212 012 2.293 012 2.901-012 2.366 012 2.439-012 2.471-012 2.372 012 4.182 012 8.05+004 1.952 012 2.026-012 2.552-012 2.091-012 2.157*012 2.189 012 2.104-012 3.691-012 8.50+004 1.773*012 1.841-012 2.311 012 1.901 012 1.963-012 1.994 012 1.919-012 3.353-012 9.00+004 1.605 012 1.668 012 2.086 012 1.723 012 1.781-012 1.812 012 1.746 012 3.036-012 9.50+004 1.463 012 1.521 012 1.895 012 1.572 012 1.628 012 1.658 012 1.600-012 2.768 012 1.00+005 1.341-012 1.395 012 1.731-012 1.444 012 1.496 012 1.526-012 1.476-012 2.538-012 CLINTON-I 7-13 Rev.2-10/86 O
V - - - - _ . - - - . _ _ . - _ _ . _ - - . _ _ _ . _ _ . _ _ - - . _ . . . _ - _ l
1 CPS-0DCM I l i 1
.(/~,)
s-Table 7.2-3 i
)
WIND SPEED AND WIND DIRECTION CLASSIFICATION I 1 I
., Wind Speed (u)
Class Wind Speed (mph) Class Wind Speed (mph) 1 0.0 lu < Thresholo 6 18.'5 > u 3 2 4. 5 2 Threshold 2u J3.5 7 24.5 >u 331.5 3 3.5 >u 3 7.5 8 31.5 >u 338.5 4 7.5 >u 312.5 9 38.5 >u 346.5 5 12.5 >u jl8.5 10 46.5 >u 199.8 Wind Direction ( 0 -) Sector Wind Direction (degrees) N 348.75 > 0 j 11.25 NNE 11.25 > 0 3 33.75 s NE 33.75 > 0 < 56.25 l I ENE 56.25 > 0 1 78.75
\'- E 78.75 > 0 ~j101.25 ESE 101.25 > 0 1123.75 SE 123.75 > 0 3146.25 SSE 146.25 > 0 3168.75 S 168.75 > 0 J191.25 '
SSW 191.25 > 0 J213.75 ~~ SW 213.75 > 0 1236.25 WSW 236.25 > 9 1258.75 W 258.75 > 0 1281.25 WNW 281.25 > e 3303.75 NW 303.75 > 0 3326.25 NNW 326,25 > 0 J348.75 i F CLINTON-I 7-14 Rev.1-ll/85
s.e . . CPS-0DCM j Table 7.2-4 GASEOUS EFFLUENT RELEASE POINT CHARACTERISTICS ! HVAC Exhaust Stack SGTS Exhaust Stack' Release Point-Height (m) 61 4 61
~
Building' Height (m) 58 58 Release. Point Geometry Duct Pipe Release Point Area (m2) 11.15 0.15 'l Release Point Diameter (m) 3.77* 0.44 I i
-Annual Average Flow Rate (m3/sec) 111.71 1.89 Vertical Exit Velocity (m/sec) 10.02 12.49 l O . *Erfective 2(A/ n)b diameter l
O CLINTON-I 7-15 Rev.2-10/86
CPS-0DCM TABLE 7.2-5 l C,/ SITE BOUNDARY DISPERSION AND DEPOSITION PARAMETERS Sector Distance Release Point X7i7 Release Point IT/li j (mile / meter) (sec/m3) (m 2) l HVAC Stack SGTS Stack HVAC Stack SGTS Stack l N 0.9/1402 9.537E-7 9.537E-7 6.224E-9 6.224E-9 NNE 0.8/1341 7.543E-7 7.543E-7 5.548E-9 5.548E-9 NE 0.7/1097 8.750E-7 8.750E-7 6.616E-9 6.616E-9 ENE 0.8/1219 4.679E-7 4.679E-7 3.443E-9 3.443E-9 E 0.8/1219 5.127E-7 5.127E-7 4.040E-9 4.040E-9 ESE 3.0/4816 6.970E-8 6.970E-8 4.695E-10 4.695E-10 SE 2.4/3841 8.696E-8 8.696E-8 5.589E-10 5.589E-10 SSE 2.1/3353 8.252E-8 8.252E-8 5.398E-10 5.398E-10 S 2.1/3353 8.565E-8 8.565E-8 3.911E-10 3.911E-10 SSW 2.9/4633 4.976E-8 4.976E-8 2.318E-10 2.318E-10 SW 3.2/5121 7.591E-8 7.591E-8 2.722E-10 2.722E-10 WSW 2.1/3414 1.307E-7 1.307E-7 4.053E-10 4.053E-10 W l.4/2256 2.045E-7 2.045E-7 7.755E-10 7.755E-10 O WNW 0.7/1097 4.414E-7 4.414E-7 2.356E-9 2.356E-9 (G NW 0.9/1463 3.871E-7 3.871E-7 1.578E-9 1.578E-9 NNW 1.0/1585 5.089E-7 5.089E-7 2.640E-9 2.640E-9 j Controlling CPS RETS Pathway Sector Comments 3.11.2.1 Immersion N Considers occupancy factors for other sectors 3.11.2.1 Inhalation N Considers occupancy factors for other sectors 3.11.2.2 Air Dose N Considers occupancy factors for other sectors 3.11.2.3 Inhalation N Considers occupancy factors for other sectors 3.11.2.3 Ground Plane N Considers occupancy factors for other sectors 3.11.2.3 Cow Milk NE Nearest milk cow is at 3.2 miles in NE sector (2) 3.11.2.3 Goat Milk N No milking goats within 5 mile radius of CPS (3) 3.11.2.3 Cow Meat N 3.11.2.3 Vegetation N Noces (1) Controlling locations and sectors are based on 1987 Land Use Census. (2) Nearest milk cow is at 3.2 miles in NE sector. Milk sample is not available, alternate vegetation samples are collected in N and NE sectors. At distance 3.2 miles, D/Q in N sector is 1.295 x D/Q in NE sector. , (3) Assumes a milking animal resides at a distance of 4.5 miles from CPS in the worst case I sector as stated on page 30 of NUREG-0133. CLINTON-I 7-16 Rev.4-10/88 1
l . l-i n CPS-0DCM
'('N~s) . / . 7.3 Concurrent Meteorological Data Processing Meteorological data is acquired and processed through a model which utilizes bi-level hourly meteorological tower . data or single level joint frequency data to perform the required analysis. Three disti t re10 ace modes are treated: elevated, groun.1 and mixed. A set of five output arrays are generated for each dose , receptor location as follows: -
Relative undecayed, undepleted plume concentration { (X/Q) l Relative decayed and depleted radioiodine and particulate concentration (D2DPXQ)- Relative decaye'd noble gas concentration'(D1XQ) I
- Relative particulate and radiciodine deposition (D/Q)
- Standard deviations of the undecayed, undepleted plume concentrations I
! Since.the Regulatory Guide 1.111 depletion and deposition curves are defined only within the range 9 i encompassing 100 to 200,000 meters, analysis results are not considered valid outside this range. The following sections describe the. calculations performed by the transport and dispersion model for a one hour time interval.
7.3.1 Determination of Pasquill Stability Class
! The Pasquill Stability Class is determined by categorizing' the temperature gradient, , ,
i AT, into one ot several ranges between < t -0.900 and 0.900 *C/ meter accord.i.ng to the following equation: AT=T -T g , *C/ meter (5) l U - 1 H U
-H g 4
l i 9 1
- l
)
l CLINTON-I 7-17 Rev.2-10/86 L - ___ - _- __ __ ____ ___ _ -
CPS-ODCM where j T = Meteorological (met) tower upper level U temperature,*C
' Tg = Meteorological tower lower level temperature, C !' H = Meteorological tower upper level U instrumentation height . = 60 meters H g = Meteorological tower lower level instrumentation height = 10 meters ,
AT is then classified according to the following scheme: i
! Pasquill Stability Defining Condition A (Extremely Unstable) -0.900 <AT <-0.019 B -0.019 <aT~<~-0.017 C -0.017 <aT 7-0.015 D (Neutral) -0.015 <aT 7-0.005 ; E -0.005 <aT 7 0.015 L F 0.015 <aT 7 0.040 G (Extremely Stable) 0.040 <aT 7 0.900 Invalid AT <-0.900 ora T> 0.900 7.3.2 Calculation of Stack Height nd Speed The wind speed at the release point (HVAC Exhaust Stack or Standby Gas Treatment
- System Exhaust Stack) height, STACWS, is ~
calculated using the expressions: STACWS = WSPU (STACG/H U ) , meter /sec (6) P = log (WSPg/WSPU ) , dimensionless (7) log (H /Hy) where WSP upper met tower level wind speed, j U " meter /sec WSP g = Lower met tower level wind speed, meter /sec STACKH = Physical release point stack height P.= Wind power law exponent, dimensionless All other parameters are as defined for equation (5). CLINTON-1 7-18 Rev.1-11/85
l l l CPS-0DCM O 7.3.3 Determination of Release Mode and the Entrainment Coefficient Th.e mode of release can be elevated, ground or , mixed; the latter being a combination of the I first two. The mode of release, as well as an entrainment coefficient, TCORR, are determined from the stack height, STACH, building height, 3LDGHT, stack exit velocity,~EXITV, and the
' wind speed at the stack height, STACWS.
For effluents exhausted from release points that are higher than twice the height of adj acent solid structures, i , STACKH > 2(BLDGHT) , TCORR = 0.0 (8) i the release is considered completely elevateo
; and the entrainment coefficient is zero. For effluents released from points less than the height of adjacent solid structures, a ground-level release is assumed STACKH < BLDGHT , TCORR = 1.0 (9) ..
and the entrainment coefficient is unity. For effluents released from points or vents at the
- level of, or above, adjacent solid structures, but lower than elevated release points, 2(BLDGHT) > STACKH > BLDGHT (10) the release is treated as elevated, ground or
.! mixed according to the following ~
relationships: l ELEVATED: TCORR = 0.0 if EXITV >5 (STACWS) (ll) GROUND: TCORR = 1.0 if EXITV < STACWS (12) MIXED: TCORR = 0.30-0.06(EXITV/STACWS) if(13) 5(STACWS)]EXITV > 1.5 (STACWS) TCORR = 2.58-1.58(EXITV/STACWS) if(14) 1.5(STACWS) > EX1TV >(STACWS) In the mixed mode, the release is considered i to occur as an elevated release 100(1-TCORR)
, percent of the time and as a ground release 100(TCORR) percent of the time. Each of these, cases are then evaluated separately and the concentration X/Q calculated according to the fraction of the time each release occurs.
CLINTON-I 7-19 Rev.1-ll/85
l I CPS-0DCM 1 \ l l f1 ,
! ) i 's ' 7.3.4 Calculation of Vertical Standard Deviation I
The vertical plume spread (vertical standard l deviation), o g, is a function of the distance j from the release point to the reception point for a given Pasquill stability class. The numerical value of a is obtained by a l I polynomial fitting equation which simulates
! Figure 1 of Regulatory Guide ~1.111:
I [A + B log (X) + C (log (X))2) i o = 10 , meter (15) g where X = Distance to a specific receptor, meter A,B,C = Empirical factors which vary by 3 stability class, determined by fitting polynomial equations to the Regulatory l Guide 1.111 Figure 1 curves,
. dimensionless Empirical Factors Used in Equation (15)
Pasquill Class A B C
,f 'S ~7) A 2.79166 2.69043 1.07483 B 2.11394 1.47930 0.40676 C 1.81954 0.88317 -0.06101 D 1.51851 0.74130 -0.08699 ;
E 1.36173 0.68570 -0.11956 F 1.14613 0.66066 -0.13263
. G 1.14613 0.66066 -0.12363 ~
l ! l , Additionally, an op'tional value called the I
" mixing height lid may be specified which limits the value of a
- to be no greater than this value.
7.3.5 Calculation of the Building Wake Correction For ground-based and mixed-mode releases, an i adjustment is made in the calculation of X/Q that takes into consideration initial mixing of the effluent plume within the building wake. This adjustment is an additional factor i added in quadrature to the vertical plume . I spread equation (15): E, = [of+0.5(BLDGHT) /n ]b (16) (v ') CLINTON-I 7-20 Rev.1-ll/85 1
f l r l CPS-0DCM l (- N) , with the requirement that I
- is restricted to j values Ez j(3) (0 3).
7.3.6 Calculation of Momentum Plume Rise
- For elevated or mixed-mode releases only, the i amount of plume rise due to the initial vertical momentum of the exhausted effluent, AH, is calculated. For Pasquill stability classes A,B,C and D, AH is calculated pe'r section 7.3.6.1 for classes E,F and G, section 7.3.6.2 is used.
i l 7.3.6.1 AH For'Pasquill Class A,B,C and D l H is calculated using both equations (17) and (18) and the minimum value is selected for
- use. In addition, when the vertical exit velocity, EXITV, is less than 1.5 times the horizontal windspeed, STACWS, a downwash correction is subtracted from equation (17) per equation (19).
j AH1= 1.44(STACD)(EXITV/STACWS)2/3 (17) ;;;= (X/STACD)1/3-DOWNWASH, meter g"
- l AH2 = 3.0 (STACD)(EXITV/STACWS), meter (18)
DOWNWASH = 3.0(STACD)(1.5-EXITV/STACWS), meter (19) where l l STACD = Internal release point stack diameter ~"
= 3.77 meters (HVAC Exhaust Stack) = 0.44 meters (SGTS Exhaust Stack) l ,
i EXITV = Stack exit velocity, meter /second All other parameters are as defined previously. 7.3.6.2 AH For Pasquill Class E,F and G AH is determined by selecting the minimum value calculated by equations-(17) and (18) l t above and equations (20) and (21) below: l t
- AH3 = 4.0 [(0.5(EXITV)(STALD)) /S] , meter (20)
AH 1 /STACWS]1/3(3)-1/6 , (21) 4 = me.5 ter [(0.5(EXITV)(STACD)) , j &d 7-21 Rev.2-10/86 CLINTON-I L____________.__________
\ . l m- . CPS-0DCM ! .' /3 D where ). .
l S = Restoring acceleration per unit vertical, ~
, displacement for adiabatic motion, sec y: - 8.70E-04 (E stability) , = 1.75E-03 (F stability) 1 = 2.45E-03 (G stability) 1 All other parameters are as defined 1,n section 7.3.6.1 l
l 7.3.7 Calculation of the Effective Plume Height l The effective plume height, H, is determined
!g using section 7.3.6 results for the momentum-plume rise,AH, and the terrain height, TERAIN: ) H = STACKH +6H - TERAIN , meter (22) where e -
TERAIN = Difference between the plant base height above mean sea level (MSL) and the receptor p point height above MSL, meter az
>0.0 t
7.3.8 Determination of Affected Sectors The wind direction for the hour determines which sector will be affected. Sectors are 22.5* arcs and are classified according to the following scheme: .
~ ! R ! Sector Compass Wind Direction (WD) i Number Direction 1 N 0.0" < WD < 11.25" or 348.75 * < WD < 360.00*
2 NNE 11.25*1 WD < 33.75* 3 NE 33.75*7 WD < 56.25" 4 ENE 56.25*7 WD < 78.25' ! 5 E 78.75*7 WD < 101. 25' . 6 ESE 101.25*7 WD < 123. 75
- 7 SE 123.75*7 WD < 146. 25' 8 SSE 146.25*7 WD < 168. 75
- 9 S 168.75*7 WD < 191. 25 ' !
~
10 SSW 191.25*7 WD < 213. 75
- 11 SW 213.75*7 WD < 236.25'
! 12 WSW 236.25*7 WD < 258.75 , ! l 13 W 258.75*7 WD < 281. 25'
- 14 WNW 281. 25
- 7 WD < 303. 75 * ,
! 15 NW 303.75*7 WD < 326.25' 16 NNW 3 2 6. 2 5 * ~< WD < 348.75 * (r 'f-CLINTON-I 7-22 Rev.1-11/85
1 I l CPS-0DCM 1
~ %) For elevated releases, the wind direction at the upper met tower level is useds ground releases rollow the direction of the wind at the lower met tower level. For mixed-mode releases, two X/Q calculations are performed: , one for each of the two met tower levels. It l
the wind direction is the same at both levels, i the resulting X/Q will be summed into the same I sector; otherwise, the X/Q will be summed into
~
I the appropriate sectors. During periods of j calm wind, the wind speed is. set at one-half the anemometer threshold value and assigned the direction of the previous hour. b Calculation of Depletion and Deposition 7.3.9 Factors
, The depletion, DPF, and deposition, DPSF, factors are calculated using the curves provided by Regulatory Guide 1.111. Actual values are calculated using polynomial equations developed to simulate the Regulatory Guide curves. Both the DPF and DPSF calculations depend on the effective plume height, H, the stability class, S, and the sa distance, X, to the receptor.
The Regulatory Guide 1.111 curves represent plumes that are 100, 60, 30, and 0 l (ground-level) meters dbove the ground. For plumes between 0 and 15 meters above the . ground, the model uses the ground-level release graphs; for those between 15 and 45 meters, it uses the 30 meter curves; between ~ i 45 and 80 meters above the ground, it uses the 60 meter curves; and for those greater than 80 l meters above the ground, it uses the 100 meter curves. The model assumes that, after full plume rise is achieved, the plume cannot get higher from'the ground. The derivation of these curves assumed no change in terrain height ~with downwind distance. Since topography does change with distance, and i likewise the vertical distance between the plume centerline and the ground, it is necessary to read from more than one depletion or deposition curve of Regulatory Guide 1.111
~
as the plume travels with distance. i E 1 LA CLINTON-1 7-23 Rev.1-11/85 1 I
-3 4 't 3 i CPS 0DCM 7.3.9.1 DPF Calculation The effective plume height, H, is m
categorized into one'of four J-ranges according to the following' scheme: {
-Plume Height (meters) J Value 02 H115' ~
5 15 < H j 45 6 45 < Hj 80 7 H )80 8. the stability class is Similarly',d categorize into one of three S-ranges as follows: Stability Class S Value A,B,C 1-
.! . D 2 ' E,F,G 3 The (SJ). product is then calculated and an (A) value determined ac the-receptor ~ 4-location X according to the following-scheme (where no A value is.given, DPF=1.0):-
S*J Value X A DPF 5 X < 100 1.0 X2 100 A=1 calculated -- 6 X < isl0 1.0 X2 200 - A=5 calculated 7 X < 300 1.0 X2 300 A = 17 calculated 8 X < 600 1.0-X2 600 A = 29 calculated 10 all X 1.0 12 X < 400 1.0 X2 400 A=9 calculated
. 14 X < 1000 1.0 ; X21000 A = 21 calculated l
15 all X 1.0 i 16 X < 1700 'l.0 l X 21700 A = 33 calculated
, 18 X < 6000 1.0 l X2 6000 A = 13 calculated. - 21 X < 60,000 1.0 ' X2 60,000 A = 25 calculated .
24 all X 1.0 CLINTON-I. 7-24 Rev.1-11/85 in .... -
CPS-0DCM O) DPF is calculated using the value for A and equations (23) and (24): (23) ! DPF = B(A) + B(A + 1)d + B(A +2)d2 + b(A + 3)d3 d = log (X) (24) . The corresponding values for the B(A), B(A + 1), B(A + 2) and B(A + 3) terms are i as follows: B(1) = .788234 B(19) = .426473 B(2) = .207198 B(20) = .0471767 B(3) = .0563034 B(21) = .615442 i B(4) = .0 B(22) = .317258 B(5) = 2.59508 B(23) = .0631839 ) B(6) = -1.43610 B(24) = .0 B(7) = .433300 B(25) = -6.89581
, B(8) = .0466221 B(26) = 3.37961 B(9) = 1.507264 B(27) = .361582 B(10) = .2745668 B(28) = .0 B(11) = .0556577 B(29) = 3.58532 B(12) = .007670194 B(30) = -2.21101 B(13) = -18.01858857 B(31) = .642613 B(14) = 12.755137 B(32) = .0651465 .=
B(15) = -2.7658938 B(33) = .234274 ' B(16) = .19103896 B(34) = .512656 B(17) = 2.47756 B(35) = .0857995 B(18) = 1.36010 B(36) = .0 7.3.9.2 DPSF Calculations Using the same (SJ) and X values determined in section 7.3.9.1, a corresponding C value is defined accor81ng i to the following scheme (where no C value l's given, DPSF = 0): i l
- 7-25 Rev.1-11/85 CLINTON-1
i t <. l 1 f CPS-0DCM e S*J l
%{' Value X C DPSF s
5 X < 100 0 X 2100 C=1 calculated 6 X <100 0 X > 100 C=8 calculated
-: 7 X 7100 0 X > 100 C = 29 calculated 8 X < 100 0 , X 2100 C = 50 calculated 10 all X 0 .
12 X <100 0 I X >100 C = 15 calculated ' 14 X < 120 0
- X >120 C = 36 calculated i 15 afl X 0 l' 16 X ' < 210 0 1 i X >210 C = 57 calculated !
18 X 7 2900 0 X >2900 C = 22 ' calculated 21 X 726,000 0 X >26,000 C = 43 calculated l 24 all X 0 l I Q4
/^s DPSF is calc,ulated using the value for C
() and equations (24), (25), and (26): ; Y DPSF - 10 /(0.392699X) (25) Y = A(C) + A(C+1)d + A(C+2)d2 + A(C+3)d3 (26) l 4
+ A(C+4)d0 + A(C+5)d5 + A(C+6)d6 I
l O i 1
? %J CLINTON-I 7-26 Rev.2-10/86
_ _ - _ _ _ _ _ _ _ _ __. _. 1
CPS-0DCM I The corresponding values for the A(C),
-) A(C+1), A(C+2), A(C+3), A(C+4), A(C+5) and.
A(C+6) terms are as follows: A(1) = -3.17821 A(33) = 7.552876 A(2) = .153463 A(34) = .82569984 A(3) = .0759066 A(35) = .036134823 A(4) = 0. A(36) = -53.7335 45.3671 l A(5) = 0. A(37) = l A(6) = 0. A(36) = -15.3282 A(7) = 0. A(39) = 2.24735 A(8) = -25.7331 A(40) = .122674 A(9) = 26.2738 A(41) = 0. j A(10) = -11.3014 A(42) = 0. i A(ll) = 2.04278 A(43) '-674.351 A(12) = .134412 A(44) = 384.531 A(13) = 0. A(45) = -73.7766 A(14) = 0. A(46) = 4.72041 A(15) = -47.5827 A(47) = 0.
. A(16) = 43.8050 A(48) = 0. ' A(17) = -16.0781 A(49) = 0.
i A(18) = 2.53726 A(50) = -55.5622 A(19) = .148044 A(51) = 53.6534 A(20) = 0. A(52) = -20.6300 A(21) = 0. A(53) = 3.44177 en i I-', A(22) =-128.5278 A(54) = .212314
] A(23) = 77.28943 A(55) = 0.
0.
~
j A(24) = -15.90284 A(56) = A(25) = 1.071885 A(57) = 436.987302 A(26) = 0. A(58) -755.860224 A(27) = 0. A(59) = 515.64145
} A(28) = 0. A(60) =-181.713295 A(29) = 41.824767 A(61) = 35.153579 A(30) =-103.969677 A(62) = -3.558356
- A(31) = 86.215344 A(63) = .14774-
, A(32) = -35.1021096 7.3.10 Ground Level X/Q, D2DPXQ, DlXQ, D/Q Analysis 7.3.10.1 Undecayed, Undepleted Plume Relative Concentration, X/Q l The atmospheric concentration of effluent at ground level, normalized by the source term Q, is given by the following equation:
X/Q = 2.032(TCORR) , sec/m (27)
- WSP (X)Amin where A
min
= The lesser of the two values obtained by equations (28) and (29), meter j) A.7 (o +gg)b, meter (28)
CLINTON-1 7-27 Rev.1-11/85
, ,~ i , , H y ~ CPS-0DCM l A
2
" (3)y O z , meter (29) 3 = The constant (2/ w)b divided by 2.032L the width in radians of a 22.5*
sector (i.e.,n/8), dimensionless-X = Distance between release point ~to receptor, meter ( i
. 7.3.10.2 Decayed, Depleted Radioio' dine and Particulate Relative Concentration, D2DPXQ The decayed, depleted radiciodine ; concentration, D2DPXQ, is calculated'in accordance with the following equations. ,
s l D2DPXQ = DPF (DC2) X/Q , sec/m (30) i where I j DPF = The depletion factor calculated per-
'-. section 7.3.9, dimensionless DC2 = The radiciodine decay factor, dimensionless ;L = exp [-0.693(X)/tg'(WSP )) = exp [-0.693(X)/(8 day)(24 hr/ day) -
(3600 sec/hr)(WSPg ))
= exp [-1.00E-06 (X/WSPt ))
- j. -.
i I
.l .
i CLINTON-I 7-28 Rev.1-11/85 i i
CPS-0DCM
'- 7.3.10.3 Decayed Noble Gas Plume Relative Concentration, DlXQ The decayed noble gas plume relative concentration, DlXQ, is calculated in , accordance with the following equation:
3 i
,. DlXQ = DCl (X/Q) , sec/m (31) where DCl - The noble gas decay factor, dimensionless = exp I-0.693(X)/t,(WSP g)]
i l l = exp [-0.693(X)/(2.26 day)(24 hr/ day)
; (3600 sec/hr)(WSPg )] = exp I-3.55E-06 (X/WSP )]
7.3.10.4 Radioiodine and Particulate Relative j Deposition, D/Q s
'?
9 , The relative deposition for radiciodines and particulate, D/Q, is calculated in accordance with the following equation: D/Q = DPSF(DC2)(TCORR), m -2 (32) (2n /16) X
~~
where { DPSF = The deposition factor ycalculated t per section 7.3.9, m 7.3.11 Elevated X/Q, D2DPXQ, DlXQ, D/Q Analysis 7.3.11.1 Undecayed, Undepleted Plume Relative Concentration, X/Q
! The atmospheric concentration of effluent l at ground level, normalized by the source .i term Q, is given by the following l
equation: I - t i 7-('~' ) CLINTON-I 7-29 Rev.1-11/85 l
CPS-0DCM ) a sec/m a (33) X/Q = 2.032(1-TCORR)exp[-0.5(H/ o z) ], STACWS (X) a where all parameters are as previously' defined. i 7.3.11.2 Decayed, Depleted Radioiodine and Particulate Relative Concentration, D2DPXQ
; The calculation of D2DPXQ for elevated ; releases follows section 7.3.10.2 , methodology with the exception that the WSP g value used in the calculation of DC2 ;' in equation (30) is replaced by the STACWS s
value and the equation (33) X/Q is used. 7.3.11.3 Decayed Noble Gas Plume Relative Concentration, DlXQ l The calculation of DlXQ for elevated i releases follows section 7.3.10.3 methodology by substituting the equation (33) X/Q value into equation (31) and STACWS for USP in the calculation of DCl. ;; 3 7.3.11.4 Radioiodine and Particulate Relative Deposition, D/Q The calculation of D/Q tor elevated releases follows section 7.3.10.4 methodology by substituting (1-TCORR) for the TCORR term in equation (32) and STACWS for WSP 3 in the calculation of DC2.
.l ; 7.3.12 Short Term Dispersion Calculations 4
Airborne releases are classified as short term in NUREG-0133 if they occur at a frequency less than 500 hours during a calendar year not to exceed 150 hours in any quarter. NUREG-0324 entitled XOQD0Q, PROGRAM FOR THE METEOROLOGICAL EVALUATION
. OF ROUTINE EFFLUENT RELEASES AT NUCLEAR POWER STATIONS, presents a method for obtaining dispersion parameter values for I short term releases. The method involves l calculating a short term correction factor, F, which relates the short term dispersion value to the annual average ! dispersion value. This same correction -
j factor is then applied to all the dispersion and deposition values (DlXQ, D2DPXQ, D0Q) to obtain the corresponding s, short term values. CLINTON-1 7-30 Rev.1-ll/85
l 1
,\
CPS-0DCM \ 7.3.12.1 Standard Deviation of X/Q !
/
i The standard deviation of X/Q, divided by X/Q, for each receptor location is calculated by equation (34):
= (n/n-1)b [n [(X/Q)2 -
([X/Q)2]b X/Q (34) 2X/Q n where n = Number of hours of valid data [" = Summation over all the X/Q values obtained by equation (27) at a receptor location for the specified time period.
' The value calculated by equation (34) is l
used to specify an exponent, S, used to calculate the short term correction factor. ; 7.3.12.2 Short Term Correction Factor Calculation The short term correction factor is calculated by equation (35): F = (Ts /T a) where T, = Total number of hours of the short term release. . j ,
' T = Total number of hours in the analyzed period.
S = Correction factor exponent calculated by equation (36). S = log [X/Q / (X/Q +o)) = -log (1+ c/X/Q) (36) log T log T h CLINTON-I 7-31 Rev.1-ll/85