PUBLIC SERVICE ELECTRIC AND GAS COMPANY HOPE CREEK GENERATING STATION DOCKET NO. 50-354 PRIMARY REACTOR CONTAINMENT PREOPERATIONAL INTEGRATED LEAKAGE RATE TEST FINAL REPORT MARCH 1986 i O
SUBMI'ITED TO TIIE UNITED STATES NUCLEAR REGULATORY COMMISSION O
ISI-22/4 , REV.00 ,
8604090111 860407 PDR ADOCK 05000354 A PDR
P PRIMARY REACTOR CONTAINMENT PREOPERATIONAL INTEGRAT.ED
- LEAKAGE RATE TEST I / FINAL REPORT i MARCil 1986 i
l TABLE OF CONTENTS thtroduction 1 1.0 -
l 2.0 Test Data Summary 2 Test Report 4
- 3.0 9
4.0 Instrumentation and Data Reduction 9 ,
f 5.0 References 16 1 6.0 Appendixes e
A. - ILRT Stabilization Data B. - 1LRT Data ,
i C. - ILRT Plots
- p. - individual Instrument Data E. e Individual Instrument Plots F. -
Verification Flow Test Data G. - Bypass Leakage R. ate Data ,
H.
- Instrument Locations ,
- 1. - Weighting Factors ,
J. - Local Leakage Rate Testing Summary .
K. - Schematic Arrangement - ILRT Data Acquisition system 1S1-22/4 i Bev . 0() ,
1.0 INTRODUCTI r iN The Primary Reactor Containment Integ ra tert Leakage Rate (Type A) Test is performed to deronstrate that leakage thru
~
the primary containment and systems and components that penetrate the primary containment does not exceed the alli>wable leakage rate as specified in the Hope Creek Generatind Station Final Safety Analysis Report.
This.preoperational test was successfully concluded on January 3, 1986. The test consisted of the ILRT, supplemental verification test and the crywell to suppression cnanber-bypass test, tither f unctions were performed just prior to the 1LRT consisting of pressure test visual examinations to complete ASME Section III construction requirements; and pressure test visual examinations to complete repairs and modificationa in accoraance with ASME Section XI. In addition the response of drywell piessure instrumentation was tested.
l This report addresses only the primary containment
,I n teg ra te d Lenkage Rate Test and the drywel) to suppression chanter bypass test. The test results are reported in accordance with the requiremtnt4 of 10CFRSO, Appendix J, Eection V.H.3.
The test program select.ed was tull pressure test.ing which will be repeated in all subsequent periodic tests. A
~
summary of the test data is four.d in section 2 ot this report, with the full tent report in section 3 which conta,ina an analysis and interpretation of the leakage rate test dsta. Section 4 describer. the instrumentation used tor the test, as well as cetails at the computer prograns'and E schen.atic arrangement of the leakoge rate incasurement system.
1S7-22/4 pace 1 of 16 Fev. 00 u - - - _ - -
2.0 TEST DATA
SUMMARY
fwJ\> This section contains plant specific data as well as a summary of the ILRT and VLRT test results.
2.1 PLANT INFORMATION OWNER: Public Service Electric and Gas Company
$ Docket Number: 50-354 Plant: Hope Creek Generating Station Location: Hancocks Bridge, New Jersey Containment Type: Mark I NSSS Supplier / Type: General Electric Co./BWR 4 Date Test Completed: January 3, 1986 2.2 TECHNICAL DATA - PRIMARY CONTATNMENT Containment net free air volume (V): 302, 500 CuFt.
() Design Pressure (Pd):
Design Temperature - drywell/ torus (Td): 340*F/310*F 62 PSIG Calculated Peak Accident Pressure (Pa): 48.1 PSIG .
Calculated Peak Accident Temperature-Drywell (Ta): 340*F Calculated Peak Accident Temperature:
Suppression Chamber (Ta): 212*F ,
Containment ILRT Average Temperature Limits: 40*F-120*F Design Leakage Rate (Ld): ' O.5 Wt.%/ day Maximum Allowable Leakage Rate (La): 0.5 Wt.%/ day Type A Test Leakage Acceptance Criteria:
(75% of La) 0.375 Wt.%/ day ISI-22/4 Page 2 of 16 Rc". 00 t
l l
I , .-- . , -- -- - - - - , - - . ..- , ,
c . - . -
2.3 ILRT DATA Test Method: Absolute Os Data Analysis Technique: Mass Point Test Pressure Requirement: 48.1 (+2.0, -0.0) PSIG Test Pressure - Actual: 49.23 PSIG Leakage (Wt%/ day):
REGRESSION ANALYSIS AT 95% UCL ACCEPTANCE CRITERIA Measured Leakage (Lam): 0.176 0.181 0.000 Level Corrections: 0.000 4
Valves out of LOCA Alignment: 0.012 0.012 Valves isolated' during ILRh: 0.000 0.000 0.193 0.375 Corrected Total 0.188 Leakage Rate:
1 2.4 S11PPLEMFNTAL (VLRT) TEST DATA Test Method: Superimposed Leak Test Pressure - Actual: 49.02 PSIG Applied Leakage (Lo): 0.462 Wt. %/ day Lcakage (Wt. %/ day):
Acceptance criteria Actual Measure Leakage Acceptance Criteria Lower Limit Composite Leak Rate Upper Limit I
Lc i (Lo + Lam + 0.25 La)
(Lo+ Lam-0.25La)] 1 0.507 0.571 0.763 f' -
kss)/
- ISI-22/4 Page 3 of 16 Rev. 00
~
3.0 TEST REYORT f
/ 3.1 PREPARATIONS FOR TEST
- (.
Significant test preparation activities performed and documented in accordance with the preoperational ILRT test procedure included the performance of all required Type B and Type C local leakage rate testing. Three (3) valves failed the local leakage rate testing at the time or the ILRT namely, 1-AE-V003, 1-BC-HV-F041H and 1-AH-HV-F022A. These valves were reworked and retested subsequent to the ILRT.
.The test instrumentation was calibrated within six (6) months and tunctionally checkea. The data acquisition system was operational and the analysis computer was programmed. The official log of events was established. The temperature survey was performed and the general inspection or the primary containment was completed. The recording of meteorological cata was
[~]'
\ initiated and three (3) drywell cooler fans were operating with the blades set back. .
Valve and electrical lineups were established per the procedure and verified, and plant systems were placed in configuration to support the ILRT. The pressurizing facility was set up and a moditied controlled access plan was placed into effect. The final briefing of test personnel was conducted.
Prior to pressurizing, a motor operated containment isolation valve stroking program was conducted to ensure these valves were closed by their normal remote-means.
Rev. 00
/~N ISI-22/4 Page 4 of 16
'x_-) ,
l l
3.2 CONTAINMENT PRESSURIZATION Pressurization commenced at 5:31 A.M. on December 28,
(<~ ) 1985 tor ASME Section III (SIT) completion pressure test examinations. Various pressure holds as required were performed prior to reaching design pressure (62 PSIG) which was attained at 4:38 P.M. on December 28, 1985. These examinations, as well as examinations required due to repairs and modifications to the primary containment performed under ASME Section XI, were completed at 0:54 A.M. on December 29, 1985.
Depressurization to less than 85% of ILRT test pressure was then initiated. Because of some leaks noted during this SIT completion test, depressurization continued down to approx. 8.1 PSIG, to enable repairs prior to the ILRT itself.
Following the repairs, pressurizing for the ILRT commenced at 3:00 A.M. on December 30, 1985. The 24
() hour period for maintaining containment pressure to less than 85% Pa (40.8 PSIG) was satisfied at 4:30 A.M., and ILRT pressure was attained at.8:'373,).M. on' December 30, 1985. Prior to initiating the temperature stabilization program, a restroking program of remote operated containment isolation valves was conducted.
Upon completion of the restroking program, containment pressure was increased slightly to 49.33 PSIG.
3.3 CONTAINMENT STABILIZATION The temperature stabilization program was initialized at 11:55 P.M. on December 30, 1985 with the temperature stability criteria being satisfied at 3:55 A.M. on December 31, 1985. The temperature stability data is shown in Appendix A.
b
\/ Rev. 00 ISI-22/4 Page 5 of 16
(
3.4 ILRT .
A
( ,) The ILRT program was initialized at 4:21 A.M. on December 31, 1985 and continued for a full 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period.
Two (2) of the instruments were determined to be malfunctioning for the duration of the ILRT and subsequent VLRT. Dewpoint sensors No. 2 and No. 3 located at Azmuth 45', Elevation 100' and Azmuth 165 ,
I Elevation 100' respectively were later determined to have blown fuses in the mirror heater circuit.
As a r8'sult of these malfunctions, data from these sensors was not used. The weight factors of the remaining dewpoint sensors was recalculated as was the Instrument Selection Guide (ISG). The weight factor data is shown in Appendix I, while the ISG data is shown in Section 4.
Additionally, the ILRT data was recalculated based upon the reassignment of weight factors for the entire ILRT. This data reveals the measured leakage rate (Lam) by regression analysis to be 0.176 Wt %/ day, and the measured leakage rate at 95% Upper Confidence Limit (UCL) to be 0.181 Wt. %/ day. The ILRT data is shown in Appendix B. Plots of the ILRT data are in Appendix C and the data and plots tor each ILRT instrument are shown in Appendix D and Appendix E respectively.
There was a net decrease in water levels of the reactor vessel, suppression chamber and the drywell floor and equipment drain sumps. This decrease in water volume is taken into account in the leakage rate measurements and does not mask an in-leakage, therefore it is not s ,
added as a correction.
ISI-22/4 Page 6 of 16 Rev. 00 ,
An cdaition of 0.012 Wt.%/ day was mace for penetrations.
that were not in the postulated accident alignment for the ILRT. These penetrations were used for sensing b(~'\ ILRT pressure, supplying cooling water to the drywell cooler fans, and for the pressurizing path. Also included is the leakage thru KL-HV-5148 for which it was indeterminate whether the valve was properly seatec
'or the ILRT. Plus during the post ILRT walkdown a number of instrument penetrations that are normally open to containment atmosphere were found to have protective covers installed, theretore, may not have been exposed to ILRT pressure. These penetrations were local leak rate tested atter the ILRT and the leakage results are included in the 0.012 wt.%/ day.
No leakage paths had to be isolated during the test becaisse of excessive leakage, therefore no corrections were made.
The corrected total leakage rate was 0.188 Wt.%./ day by the regression analysis, and 0.193 Wt%/ day at 95% UCL.
The ILRT was concluded at 4:35 A.M. on January 1, 1986.
3.5 SilPPLEMENTAL (VLRT) TEST A successfrl veritication leakage rate test (VLRT) was performed following to the ILRT using the superimposed leakage method. A known leakage rate (Lo) of 0.470 Wt%/ Day (4.269 SCFM) was imposed on containment at 5:01 A.M. on January 1, 1986. The containmeitt atmospheric conditions were stabilized prior to initializing the VLRT progren at 8:11 A.M.
. )
ISI-22/4 Page 7 of 16 Rev. 00 1
As with the ILRT, the data for the VLRT was recalculated due to the two (2) dewpoint temperature
() sensor malfunctions. The VLRT was concluded at 12:11 P.M. on January 1, 1986 with a composite leakage rate of 0.571 Wt%/ day which was within the acceptance criteria range of 0.507 Wt.%/ day to 0.763 Wt%/ Day. The VLRT data is shown in Appendix F.
3.6 DEPRESSURIZATION AND DRYWELL HYPASS TEST Upon completion of the supplemental VLRT test the containment was depressucized starting at 1:30 P.M. on January 1, 1986 and was fully depressurized at 10:28 P.M.
The drywell to suppression chamber vacuum' relief valves were then repositioned, and the suppression chamber level was increased to ensure that sufficient submergance would be attained for the vent pipe drain lines.
Pressurization of the drywell for the bypass test ccamenced at 11:06 P.M. on January 2, 1986, with test pressure of 1.129 PSIG being attained at 11:43 P.M.
Following a one (1) hour stabilization hold, test data was recorded. The maximum differential pressure recorded was 0.083 inches of water per minute. The acceptance criteria of 0.250 inches of water per minute for 10 minutes was satisfied, at which time depressurization commenced. The test data is shown in Appendix G. Depressurization was completed at 2:10 A.M. on January 3, 1986 at which time restorations were started.
O ISI-22/4 Page 8 of 16 Rev. 00
4.0 INSTRUMENTATION AND DATA REDUCTION
) 4.1 INSTRilMENTATION DESCRIPTION The following instruments were utilized for both the ILRT and the supplementary VLRT. The pressure instruments were used for the bypass test as well.
A) Absolute pressure Ouantity: Two (2)
Type: Ouartz Bourdon Tube Range: 0 to 100 PSIA Accuracy:
- 0.15% F.S.
Repeatability: 0.001% F.S.
B) Drybulb temperature Ouantity: Seventeen (17)
Platinum RTD's
( Type:
0 to 150'F Range:
Accuracy:
- 0.1
- F ( in 60 to 120*F range)
Repeatabiltiy:
- 0.l*F C) Dewpoint temperature Ouantity: Six (6)
Type: Chilled mirror .
Range: -40*F to 80*F Accuracy:
- 0.40*F r
Sensitivity: 0.05*F l
l l
l l
l l
O ISI-22/4 Page 9 of 16 Rev. 00
D) Verification flowmeter i Ouantity: one (1) b(~\ Type: Thermal mass Range: 1 to 10 SCFM Accuracy:
- 2% F.S.
' Repeatabilty: i0.25% F.S.
l 4.2 INSTRUMENT LOCATIONS j
The locations of the drybulb and dewpoint sensors are shown in Appendix H.
4.3 WEIGHTING FACTORS The recalculated weighting factors are shown in Appendix I.
4.4 INSTRUMENT SELECTION GUIDE (ISG)
O The results of the ISG calculations, based upon the deletion of the No. 2 and No. 3 Dewpoint tempe,ature r sensors is as follows:
Instrument Sensitivity Number of Measurement Total Parameter Error Sensors Error Error i Pessure 0.001 2 0.0015 0.00127 Dewpoint Temp. 0.050 4 0.0030 0.00023 Drybulb Temp. 0.010 17 0.0040 0.00261 1
Instrument selection guide (ISG) %/ day = 0.0029 l
)
1
(::) 1S1-22,4 eage 10 et 1e Re . e0 1
-_m
4.5 DATA REDUCTION
() The instrument outputs were communicated to a data acquisition system (DAS) in both analog and paralled BCD forms. The data acquisition control unit provided analogtion multiplexing and digital monitoring which in turn communicated via an IEEE-488 interface to the mini-computer (HP-9836). A schematic arrangement of the leakage rate measurement system is shown in Appendix K.
The computer program used for the data acquisition and compilation, calculation of the leakage rate and the analysis of thi.s data were developed by PSE&G Research
. Corporation, Research and Testing Laboratory specifically for the purposes of containment integrated leakage rate testing. The formulas used in these test programs are taken f rom the formulas and guidelines presented in ANSI N45.5-1972, ANSI /ANS 56.8-1981, and
() ANS 274. The computer program logic is controlled by user options (Menu) The Menu options and a description of the function of each'sub program are as follows:
MENU 1 SET TIME -Sets the computer and data acquisition system clock with the correct date and time.
ENTER SENSOR WEIGHTING FACTOR - Allows the user to enter each sensor's (RTD, Dew Point, Pressure) subvolume weighting factor. It determines if the weighting factors total 100% and if so proceeds to create a file with the data.
\- IFI-22/4 Page 11 of 16 Rev. 00
CHANGE WEIGHTING FACTOR - Allows the user to charge a sensor's f h assigned weighting factor during the test. If a sensor V fails during test its weighting factor can be reassigned to adjacent sensor or split between several sensors. The computer determines if the weighting factors total 100%, and if so, proceeds to create a file with the data.
PRINT WEIGHTING FACTOR- Prints a hard copy of the weighting factor.
ENTER LABEL - Allows the user to enter appropriate identification for all sensors (RTD, Dew Point, Pressure).
CHANGE DATA - At any time during test, after changing the changing the weighting factors, the test data can be recalculated using the previous recorded raw data minus
() the incorrect sensor data.
MENU 2 CONTAINMENT CONDITION (CONT-COND). The' containment condition sub program scans all test sensors through the Data Acquisition system (DAS) at the preset time interval (1 min-24 hour) and is used as interim tests, before and during pressurization and depressurization.'
It calculates the weighted average containment temperature, dew point, pressure, pressurization rate (calculated per scan expressed as psia / hour), the differential temperature between the containment temperature and dew point temperature, a n' +he percent relative humidity. The data is stored on file (CONTDATA) and results printed after each scan.
ISI-22/4 Page 12 of 16 Rev. 00 t
l
STABILITY - The temperature stability test scans all test sensors 7-s (DAS) at the preset time interval (1 min -24 hour). It
( ,)
then calculates the weighted average containment, temperaturc, dew point, pressure. The containment temperature stability is calculated in accordance with ANSI /ANS 56.8 1981 Appendix F. The data is stored on file (STABDATA) and results printed after each scan.
INTEGRATED LEAKAGE RATE TEST - The Integrated Leakage rate program scans all test sensors (DAS) at the preset time interval (1 min - 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />). It then checks each sensor to determine the differential from the last scan.
(RTD's 1*F, Dew Point 5"F, pressure 0.1 PSIA) If the differential exceeds the allowable a warning message is printed with the sensor number and the differential.
This allows the test engineer to monitor this sensor and determine what action to initiate. The weighted average containment temperature, dew point and pressure
() are calculated and these are then used to calculate the containment mass. If sufficient data scans have been recorded (6 scans) the least square regres.s. ion is i
calculated and the slope (Lbm/hr) recorded.
The percentage daily leakage rate is calculated trom the rate of change of mass and the mass (intercept) in the containment at each scan. The uncertainty in the estimated value is assessed in terms of the standard deviation of the slope, intercept and their convariance, followed by the compution of an upper limit of the 95th confidence level.
The data is store on file (ILRTDATA) and results printed after each scan.
O ISI-22/4 Page 13 of 16 Rev. 00
VERIFICATION - The verification test supsrimposed leak is manually initiated and adjusted to the desired flow, ft then the verification program is initiated. The s
program scans all test sensors (DAS) at the preset time interval (1 min- 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />). The data acquisition system also determines the flow from the thermal mass flowmeter which is monitoring the superimposed leak.
The computer continues to calculate the leakage rates as in the ILRT program and also calculates the The superimposed leakage using the superimposed flow.
data is stored on tile (VERDATA) and results printed after each scan.
MENU 3 PRINT RAW DATA - At any time during tests the raw data from all sensors for any scan (10 scan minimum) can be printed.
PLOT SENSORS - A plot of any individual sensor (RTD, Dew Point, Pressure) can be viewed on the CRT and a hard copy plotted if desired.
PLOT AVERAGES - A plot ot any containment weighted average, temperature, dew point or pressure can be viewed on the CRT and a hard copy plotted if desired.
I
~
MASS PLOT - A Plot of the containment mass can be viewed on the CRT and a hard copy plotted if desired.
l
?
Page 14 of 16 Rev. 00 ISI-22/4
---,e. - - - - - - , . -e----,-n-- n.e < e - - - -r
l 4
l J
i LEAKAGE RATE-PERCENT / DAY - A plot of the containment leakage {
1 rate and upper confidence level in percent / day can be 4
i viewed on the CRT and a hard copy plotted if desired. 1 1
I LEAKAGE RATE - Lbm/Hr- A plot of the containment leakage rate :
1 and upper confidence level in pounds mass per-hour can :
1 1
be viewed on the CRT and a hard copy plotted if l
desired.
t i
i a
.i I
1 4
i I
l l
1 i
i i
i i
.l 1
j ISI-22/4 Page 15 of 16 Rev. 00 i
i l
i
(
- m-~r ww---ew---------e-,--mev-,,,,c&-, .-,c-,,,w.m w v
_,w-e ry,ee-c.wvw-tr,,,v-w,w,,--m-w-,-,,-ey.,,,'-c,ww.ww e-%e-,-,e*,-. , w w =. mv.-p e ysw -
r O
5.0 REFERENCES
5.1 10CFR50, Appendix J., 3/6/73 as ammended - Primary Reactor Containment leakage Testing for Water -
cooled Power Plant Reactors.
5.2 ANSI N45.4 - 1972 - Leakage Rate Testing of containment structures for nuclear reactors.
5.3 ANSI /ANS 56.8 - 1981 - Containment Systems Leakage Testing Requirements.
5.4 Public Service Startup Group Preoperational Test Procedure No. PSSUG-PTP-GP-1, Rev. O, Primary Containment Integrated Leakage Rate Test.
O
~
O ISI-22/4 Page 16 of 16 Rev. 00
Appsndix A Sheet 1 30 Dec 1985 HOPE CREEK GENERATING STATION TEf1PERATijRE STABILITY STABILITY
- EIENT CONTAINMENT PRESS f1 ASS AVG O!FF/4hr (M;O!FF/1hr AVG O!FF SCAN TifE PRESS TEftP TEf1P DEW PT Psia Lba DegF DegF DegF No. Hour Psia DegF DegF DegF 71.35 64.25 97372 0.00 0.00 0.00 1 23:55 14.93 39.87 75.96 t
75.92 71.37 64.25 97M6 0.00 0.00 0.00 2 00:10 14.93 38.41 75.85 71.33 64.24 97359 0.00 0.00 0.00 3 00:25 14.9) 38.15 75.83 71.33 64.24 97358 0.00 0.00 0.00 ,
4 00:40 14.93 37.90 i
75.81 71.29 64.23 97MS 0.00 0.00 0.00 5 00:55 14.93 38.16 75.80 71.30 64.23 97355 0.00 0.00 0.00 6 01:10 14.92 38.00 75.79 71.28 64.23 97352 0.00 0.00 0.00 7 01:25 14.92 37.68 37.09 75.72 71.28 64.22 97350 0.00 0.00 0.00 8 01:40 14.92 1
36.83 75.78 71.26 64.22 97346 0.03 0.00 0.00 9 01:55 14.92 36.56 75.77 71.26 64.22 97344 0.00 0.00 0.00 10 02:10 14.92 36.97 75.76 71.27 64.22 97342 0.00 0.00 0.00 11 02:25 14.91 37.35 75.70 71.24 64.21 97350 0.00 0.00 0.00
. 12 02:40 14.91 37.33 75.69 71.26 64.21 97346 0.00 0.00 0.00 13 02:55 14.91 37.52 75.68 71.24 64.21 97346 0.01 0.00 0.00 14 03:10 14.91 i
37.43 75.67 71.24 64.21 97345 0.00 0.00 0.00 15 03:25 14.91 37.97 75.67 71.24 64.20 97340 0.00 0.00 0.00 16 03:40 14.91
, 1
._ . _ . - . ~ _ . . . . _ . .~. . . _ . - . - - - ~ . . . . . - . . . - _ . . _ _ - . . __ - -
t f
Appendix A 4l -Sheet 2 i
l
' 31 Dec 1985 ll
- HOPE CREEK GENERATING STATION 1
i TEf1PERATURE STABILITY CONTAIN!1ENT STABILITY A11ENT l TEl1P DEW PT PRESS t1 ASS AVG DIFF/4hr AVG 0!FF/1hr AUG O!FF j SCAN Tir1E PRESS TErP Psia Lbn DegF DegF DegF ,
! No. Hour Psia DegF DegF DegF 1
64.20 97338 .07 .02 .05 17 03:55 14.90 38.17 75.67 71.23 i
64.20 97341 .07 .04 .03 4 18 04:10 14.93 38.26 75.64 71.24 i,
I 64.02 97020 .08 .05 .02 19 19:21 14.95 41.71 76.06 69.29 j
3 1
i 4
i
]
i 4,
en s
e 4
l 1 ,
1 i i 1
i
}
f I
Appendix B l Sheet 1 l i l l
O 31 Dec 1985 HOPE CREEK GENERATING STATION l RECALC-MASS PLOT DATA I AfE!ENT CONTAINMENT SCAN Tite PRESS TEMP TEff CEU PT PRESS MASS LEAK RATE UCL 95% CALC MASS No. Hour Psia De;F DegF DegF Psia Lbs Lbs/Hr %/ Day Lbs/Hr 4/ Day Lba
- 1 04
- 21 14.90 38.64 75.65 69.23 64.20 97373 0.00 0.000 0.00 0.000 0 I 2 04:35 14.90 38.98 75.63 69.26 64.20 97374 0.00 0.000 0.00 0.000 99207 3 04:50 14.90 38.56 75.62 69.26 64.19 97371 0.00 0.000 0.00 0.000 99148 4 C5:05 14.90 38.25 75.62 69.27 64.19 97368 0.00 0.000 0.00 0.000 99889 5 05:20 14.89 38.55 75.61 69.28 64.19 97367 0.00 0.000 0.00 0.000 99029 (O) 6 05:35 14.89 38.73 75.61 69.29 64.19 97363 -10.88 .268 -13.51 .333 98970 J
7 05:50 14.89 38.84 75.62 69.26 64.18 97358 -12.20 .301 -14.80 .365 98911 l 8 06:05 14.88 38.95 75.60 69.20 64.18 97357 -11.70 .288 -13.56 .334 98852 i 9 06:20 14.88 39.17 75.58 69.25 64.18 97360 -9.66 .238 -12.82 .316 98793 5
10 06:35 14.88 39.15 75.58 69.27 64.18 97355 -9.30 . 229 -11.72 .289 98734 11 06:50 14.88 39.36 75.57 69.26 64.18 97353 -9.13 .225 -11.03 .272 98675 12 07:05 14.88 39.33 75.57 69.25 64.17 97348 -9.48 .234 -11.07 .273 98616 13 07:20 14.88 39.47 75.57 69.23 64.17 97344 -9.92 .244 -11.34 .279 98557 I i
14 07:35 14.87 39.90 75.57 69.24 64.17 97341 -10.32 .254 -11.61 .286 98490 15 07:50 14.87 39.85 75.57 69.24 64.16 97338 -10.65 .263 -11.82 .291 98439 l
I 16 08:05 14.87 40.51 75.57 69.28 64.16 97333 -11.05 .272 -12.17 .300 98379
App::ndix B Sheet 2
.i : 6.'
-'d 31 Dec 1985 HOPE CREEK GENERATING STATION RECALC-MASS PLOT DATA AMBIENT CONTAIHMENT SCAN TIE PRESS TEMP TEMP DEW PT PRESS NASS LEAK RATE UCL 95% CALC MASS No. Hour Psia DegF Degr DegF Psia Lbn Lba/Hr 4/ Day Lba/Hr %/ Day Lba 17 08:20 14.86 40.55 75.35 69.24 64.16 97333 -11.11 .274 -12.09 .298 98320 18 08:35 14.86 41.14 75.55 69.23 64.16 97332 -11.01 .271 -11.87 .293 98261 19 08:50 14.86 41.91 75.51 69.25 64.16 97338 -10.33 .255 -11.46 .282 98202 20 09:05 14.55 42.11 75.54 69.17 64.15 97329 -10.22 .252 -11.23 .277 98143 21 09:20 14.85 41.71 75.5 1 69.20 64.15 97332 -9.85 .243 -10.86 .268 98084 22 09:35 14.B5 42.41 75.48 69.24 64.15 97334 -9.33 .230 -10.44 .257 98025 23 09:50 14.55 3.75 75.50 69.25 64.15 97329 -9.06 .223 -10.11 .249 97966 24 10:05 14.85 44.09 75.47 69.22 64.15 97331 -0.67 .214 -9.74 .240 97907 25 10:20 14.85 44.87 75.39 69.26 64.15 97341 -7.88 .194 -9.24 .228 97848 26 10:35 14.84 45.34 75.40 69.20 64.14 97338 -7.32 . 180 -8.73 .215 97789 27 10:50 14.84 46.45 75.38 69.19 64.14 97338 -6.81 .168 -0.25 .203 97730 28 11:05 14.83 47.33 75.39 69.27 64.14 97331 6.57 .162 -7.93 .195 97670 4
u, 29 11:20 14.82 48.38 75.38 69.27 64.14 97330 -6.36 .157 -7.64 .188 97611 30 11:35 14.82 48.27 75.39 69.25 64.14 97328 -6.20 .153 -7.41 .183 97552 O 31 11:50 14.82 48.29 75.35 69.24 64.14 97331 -5.94 .14 -7.11 .175 97493 l
l 32 12:05 14.83 49.18 75.37 69.22 64.13 97326 -5.82 .143 -6.92 .171 97434
Appendix B Shent 3
)
l O
HOPE CREEK GENERATING STATION 31 Dec 1985 RECALC-11 ASS PLOT DATA AMBIENT CONTAIM1ENT LEAK RATE UCL 95% CALC 11 ASS SCAN Tl!1E PRESS TEMP TEMP DEU PT PRESS' HASS Lbn Lba/Hr 4/ Day Lta/He 4/ Day Lbn No. Hour Psia DegF DegF DegF Psia 97321 -5.81 .143 -6.84 .169 97375 49.67 75.37 69.23 64.13 33 12:20 14.83 97320 -5.79 .143 -6.76 .167 97316 34 12:35 14.83 50.16 75.37 69.21 64.13 97317 -5.79 .143 -6.70 .165 97257 35 12:50 14.77 49.83 75.37 69.21 64.13
-5.72 .141 -6.57 .162 97199 49.32 75.35 69.23 64.13 97320 36 13:05 14.77 64.13 97320 -5.63 .139 -6.44 .159 f/139 37 13:20 14.77 49.35 75.33 69.23
-5.54 .137 -6.32 .156 97080 38 13:35 14.77 43.80 75.32 69.21 64.12 97319 97314 -5.53 .136 -6.27 .154 97020 39 13:50 14.77 48.68 75.34 69.25 64.12
-5.57 .137 -6.27 .154 96961 40 14:05 14.77 48.21 75.33 69.26 64.12 97310
-5.53 .136 -6.20 .153 96902 41 14:20 14.77 48.73 75.30 69.20 64.12 97313
-6.18 .152 96843 42 14:35 14.78 48.94 75.31 69.22 64.11 97308 -5.55 . 137 69.22 64.11 97302 -5.62 .139 -6.23 .154 96784 43 14:50 14.78 48.10 75.32 69.21 64.11 97300 -5.70 .140 -6.28 .155 96725 44 15:05 14.78 47.62 75.32 69.22 64.11 97300 -5.74 .142 -6.31 .155 96666 45 15:20 14.78 47.58 75.31 64.11 97297 -5.80 .143 -6.34 .156 96607 46 15:35 14.78 46.52 75.32 69.26 64.11 97294 -5.87 .145 -6.39 .158 96548 47 15:50 14.78 47.30 75.32 69.23 97294 -5.91 .144 -6.42 .158 96489 l 48 16:05 14.79 46.04 75.32 69.19 64.11
App m3ix B Sheet 4 i
31 Dec 1985 HOPE CREEK GENERATING STATION t
I RECALC-NASS PLOT DATA 1
~
AMBIENT CONTAINNENT TEMP TEMP DEU PT PRESS HASS LEAK RATE UCL 954 CA.C NSS :
SCAN TIME PRESS DegF Psia Lbn Lbs/Hr 4/ Day Lbs/Hr %/0ey Lte No. Hour Ps:a DegF DegF 45.41 75.29 69.26 64.10 97297 -5.91 .146 -6.39 .15 7 9 o 41 0 49 16:20 14.79 i
75.30 69.21 64.10 97294 -5.92 .146 -6.30 .157 f4371 50 16:35 14.79 45.20 75.30 69.22 64.10 97292 -5.9) .146 -6.38 .157 h311 51 16:50 14.79 44.60 i .
44.82 75.29 69.21 64.10 97291 -5.94 .146 -6.37 .157 9??f2 52 17:05 14.79 75.31 64.10 97286 -5.98 .147 -6.39 .158 96193 53 17:20 14.79 44.83 69.15 P
44.72 75.30 t9.23 64.10 97284 -6.01 .148 -6.41 .158 96134 54 17:35 14.8G 55 17:50 14.8J 44.66 75.27 e9.28 64.10 972B2 -6.05 .149 -6.44 .159 96075 3
/
45.06 75.29 69.21 64.10 97283 -6.07 .153 -6.44 .159 96016 56 18:05 14.80 57 18:20 14.80 44.94 75.30 69.24 64.09 97277 -6.11 .151 -6.47 .160 95957 i
58 18:35 14.79 45.07 75.31 69.25 64.09 97272 -6.18 . 15 2 -6.53 .161 95898 44.67 69.28 64.09 97273 -6.22 .153 6.57 .162 95839 1 59 18:50 14.79 75.30 69.15 64.09 97272 -6.25 .If 4 -6.59 .163 95780 60 19:05 14.79 44.65 75.30 44.4') 75.30 69.22 64.09 97268 -6.30 .15 5 -6.63 .163 95721 i
61 19:20 14.79 4.4.81 75.29 69.22 64.09 97268 -6.34 .156 -6.66 .164 95661 62 19:35 ~14.77 J' ~
64.08 -6.37 .157 -6.69 .165 95602 63 19:50 14.79 44.7) 75.27 69.29 97265 97264 -6.41 .158 -6.72 .166 95543 64 20:05 14.79 45.11 75.28 69.27 64.08 i .
.,, _- , _ -. _ . _ . . . ~ _ . _ _ _ __- __ _ , . _ . _ _ , . _ . . - . _ _ _ -
Apptndix B l Sheet 5 1
i N(}' '
31 Dec 1965 HCPE CREEX GENEMT!NG STAil0N ,
RECALC-f1ASSPLOTDATA
- tilENT CONTA!N'1ENT FIAS3 LEARRATE UCL 954 CALCt1 ASS TEff TEr1P DEU PT PRESS SCAN Ti!E OPESS Lbn DegF Psia Lba Lba/Hr 4/ Day Lha/Hr %/ Day No. Hn:r Psia Def DegF 75.29 69.23 64.09 97268 -6.40 .158 -6.70 .165 95404 65 20:20 14.79 44.84 97269 -6.39 .157 -6.68 .165 95425 24 20:35 14.79 44.23 75.29 69.26 64.09
-6.38 .15 7 -6.67 .164 95366 67 2C:50 14.79 44.00 h.23 69.27 64.00 97265 97261 -6.39 .158 -6.67 .164 95307 69 21:05 14.79 44.02 75.27 69.29 64.08 97258 -6.41 .158 -6.67 .164 95248
) 69 21:20 14.79 44.34 75.28 69.25 64.0P O -6.68 .165 95189 V 70 21:35 14.79 44.57 75.27 69.26 64.08 97256 -6.42 .158 97251 -6.46 .159 -6.71 .165 95130 71 21:50 14.79 44.60 75.29 69.24 64.07 97248 -6.49 .160 -6.74 .166 95071 72 22:05 14.79 44.69 75.29 69.26 64.07 73 22:20 14.79 44.92 75.23 69.28 64.07 97247 -6.52 .161 -6.77 .167 95011 75.27 69.27 64.07 97245 -6.55 .161 -6.79 .167 94952 74 22:35 14.79 44.90 45.28 75.27 69.22 64.07 97244 -6.57 .162 6.80 .168 94893 75 22:50 14.79 ,
t 6
- 45. 72 75.31 69.32 64.07 97235 -6.62 .163 -6.06 .169 94834 76 23:05 14.79 45.52 75.29 69.35 64.07 97236 -6.66 .164 -6.90 .170 94775 77 23:20 14.79
'4.79 45.61 75.28 69.24 64.06 97234 -6.70 .165 -6.93 .171 94716 78 23:35 1 l'
Q 45 71 75.29 69.33 64.06 97231 -6.74 .166 -6.97 .172 94657 79 23:50 14.79 69.28 64.06 97233 -6.76 .167 -6.99 .172 94598 08 80:05 14.79 45.80 75.27
App 3ndix B Sheet 6 V 1 Jan 1926 HOPE CREEK GENERATING STATION RECALC-MASS PLOT DATA AMBIENT CONTAINTNT
$CAN TIFE PRESS TEMP TEMP DEW PT PRESS MASS LEAK RATE UCL 95% CALC M SS No. %r Psia DegF OegF DegF Psia Lba Lbs/Nr 4/ Day Lbe/Hr %/ Day Ltm 81 00:20 14.78 45.61 75.26 69.25 64.06 97233 -6.78 .167 -7.00 .173 94539 82 00:35 14.78 45.29 75.27 69.28 64.06 97227 -6.81 .168 -7.02 .173 94480 83 00:50 14.78 45.20 75.26 69.27 64.06 97226 -6.93 .168 -7.04 .174 94421 84 01:05 14.79 45.18 75.25 69.38 64.05 97225 -6.05 .169 -7.06 .174 94162 85 01:20 14.79 45.79 75.26 69.29 64.05 97223 -6.87 .169 -7.07 .174 94302 86 01:35 14.79 45.62 75.24 69.27 64.05 97225 -6.87 .169 -7.08 .174 94243 87 01:53 14.79 45.52 75.27 69.27 64.05 97218 -6.90 .170 -7.10 .175 94184 88 02:05 14.79 45.74 75.27 69.29 64.05 97214 -6.92 .171 -7.12 .176 94125 89 02:20 14.79 45.53 75.26 69.31 64.05 97213 -6.95 .171 -7.14 .176 94066 90 02:35 14.79 45.02 75.27 69.34 64.05 97209 -6.98 . 172
-7.17 .177 94007 91 02:50 14.79 44.32 75.27 69.31 64.04 97207 -7.01 .173 -7.20 .177 93948 92 03:05 14.80 44.29 75.27 69.32 64.04 97206 -7.03 .173 -7.22 .178 93889 93 03:20 14.80 44.25 75.25 69.24 64.04 97211 -7.03 .173 -7.22 .178 93830 94 03:35 14.00 43.47 3 .25 69.28 a.04 97209 -7.04 .173 -7.22 .178 93771 95 03:50 14.80 43.23 75.28 69.32 64.04 97198 -7.07 .174 -7.25 .179 93712 96 04:05 14.81 43.12 75.27 69.28 64.04 97197 -7.09 .175 -7.27 .179 93652
Appendix B Sheet 7 1 Jan 1986 HOPE CREEK GENERATING STATION RECALC- MSS PLOT DATA APE!ENT CONTAINhENT SCAN TifE PRESS TErF TEMP DEW PT PRESS MSS LEAK RATE UCL 9% CALC MSS No.. Hour Psia DegF DegF DegF Psia Lbn Lbs/Hr 4/ Day Lba/Hr %/ Day Lbe 97 04:20 14.81 43.01 75.27 69.30 64.04 97196 -7.11 .175 -7.29 .100 93593 l
O
, Q
^
Appendix C t l HOPE CREEK ILRT
.5 -
.45 -
LERK RRTE %/ day ( so l i d = Lam ik d ash = UCL )
4
.4
\
.35 -
/\
.3 - \ fg
- \
I
} N ;
m .25 -
- N \
i M
.2 - \
w \ ,_
i H x --
x
~~
N .15 -
- Y i
.', x .1 w -
! _1 l .05 -
I I I 1 I I I l 1 D e e s
- e e s s e N N N N N N N N i N m N ~ T
- r IN s CD
~
G1
~ N G s o e ~ ~
i TIME hour 31 Dec 1985 :
I
1 Appendix C Sheet 2 HOPE CREEK ILRT
, 20 -
e
- is LERK RRTE Lbm/ Hrs ( solid = Lam & dash = UCL) i 16 -
1 14 -
(\
12 - -
l\ /N c r g
.c I J \
E 10 -
\
1
.o N
\
8 -
x e s - s __
- N ~~___ s_ -
a g _
T
- i 4 - -
e i
d -
2 _
i I I I I I I I I i
0
~ G G G S S O S S N N N N N N N N N l
e N s m m m co - e G S ~
." " ~ N G G i
^
i TIME hour 31 Dec 1985
- fi -
.*' ' :. - * ' ~
I oNwG .
~ 8
_ C -
8
%)J x -
C i3 d nt 8
ee --.
pe - L eN~Q .
ph AS
' 8
.s .
I
- aNNN
_ - 8
,~
8
._ , 8
- I aJm~
n 3
. 8 5 .
8 -
__ T '
9 R
- 1 L ~
I aNm~
c
~ e I 3 T -
D O - 2 L ,
K P - 5
- 1 3
E S I
aNm~
E r S .
u R
R 3
M . -
- o C
8 h .
. 8 E ..
E -
I j
onm~ I 1
t P /. 8 T O
H s
I oNc.O -
%Lr.
ZeC- - . - -
, ~ c P . y C . [-anE NeG 0 0 0 0 0 0 0 0 0 0 0 _
_ 0 5 0 5 0 5 0 5 0 5 0 _
5 4 4 3 3 2 2 1 1 2 0 _
7 7 7 7 7 7 7 7 7 7 7 _
9 9 9 9 9 9 9 9 9 9 9 _
Ef mmcE i(l1!j.-,! <4 '
i1l ;; ! l .;:,j:l ;;,, ,! jiI.iii!!! ! 1 il;iI
l l
3 ,02kB l N
U c,
h .h k5
[j y.
02IO )
a .c 1
<m
} '
- n 5 -
0222
)
-4 0261 F-sn. c>
.N w !
m C
E
- y .
__J tr -
0291 H h q $
e a M b 72 O w W
e g
L Q/ :
- 02EI R
u E 3 U N m
)) .E W S (7/
<; J 0201 U
g g T h
O w F a N..-
3
- 0220 k I
/. l l
1 1 - L_. L ._. ..J _1. _.._L_._. L__L _L ._ _ _L I290 )
a m m n m tn w m cu ~ m i n . . . . . . . . . m m m m m m en en m m m m m m m m m m w O
.4 6o P 3 8 0 ,1.8 8 3 d W 3.L l
i O O O I
Appendix C i HOPE CREEK ILRT i 78 r 75.9 RVERRGE TEMPERRTURE PLOT
.l 75.8 F :
i 75.7 ;1 -
i 7 5 . 6 --
! Yn Q's~%, .s
!
- 75.5 'b i w . i tr a 75.4 i- h.sV M
F- l 75.3
~~
'hvd4
- o.
x 75.2 r;-
w l F-l 75.1j-I - -- - I----- I-- I ' ~ ' ' ~~ ' I ~ ~"' '- '- ' - l ---~ " ' - ~ . . L. _ .- . . _. J
?5 - -
s
! _ m e e e e e N N N N N N N 01 N
- T
- y G (7) CD e s g -
m ~ ~ N e ,
4 TIME hour 31 Dec 1985 ;
i
O O O Appendix C Shaat 6 HOPE CREEK ILRT s 4 . 5 ,-
RVERRGE PRESSURE 64.45 -
S4.4 r 64.35 -
84.3 r 64.25 -
I G4.2 s
1 64.15 -
B4.1 - - _
! 64.05 -
-I - J ----- L ---- L - . 1._. . _. . _ _.L - ___ L_ .___ _ J 64 o ca e s
- e e ca N N N N N N N N - e m a) N e e to
- - N G G Q
G TIME hour 31 Dec 1985 i
Appsndix D Shoot 1 g)
(
'# 31 Dec 1985 HOPE CREEK GENERATING STATION CONTAINNENT TEMPERATURE SENSOR LOCATION SCAN 1 SCAN 2 SCAN 3 SCM 4 SCAN 5 SCAN 6 SCAN 7 SCM 8 SCAN 9 SCAN 10 04:35 04:50 05:05 05:20 05:35 05:50 06:05 06:20 06:35 04:21 79.8 79.7 79.7 79.8 79.8 79.7 79.8 79.7 79.7 79.7 1 EL 162 Az 45 78.9 78.9 78.9 78.9 78.8 78.9 78.9 78.8 2 El 162 Az 165 78.9 78.8 78.8 78.9 78.8 79.0 78.9 78.8 78.9 3 El 162 4 285 78.9 78.9 78.8 79.2 79.2 79.2 79.2 79.2 79.2 79.1 79.1 4 El 122 Ar 45 79.2 79.2 78.8 78.7 78.8 78.8 78.8 78.8 78.8 78.8 5 El 122 Az 135 78.8 78.8 79.1 79.1 79.0 79.1 79.1 79.1 79.1 79.1 6 El 122 Az 225 79.1 79.7 79.2 79.3 79.2 79.2 79.2 79.2 79.3 79.2 7 El 122 4 315 79.3 79.3 77.8 77.8 77.8 77.8 77.8 77.8 77.8 77.8 77.8 8 El 100 Az 45 77.8 75.7 75.8 75.8 75.8 75.8 75.8 9 El 100 4 135 75.7 75.8 75 7 75.7 77.5 77.4 77.5 77.5 77.4 77.5 77.5 77.4 77.6 10 El 100 Az 225 77.5 78.3 78.3 78.3 78.3 78.3 78.3 78.3 11 El 100 Az 315 78.3 78.3 78.3 12 Torus Az 45 72.7 72.7 72.8 72.8 72.7 72.7 72.7 72.7 72.7 72.6 13 Torus 105 72.2 72.1 72.1 72.1 72.1 72.1 72.3 72.1 72.1 72.1 14 Torus 165 72.0 71.9 71.8 71.9 71.8 71.8 71.7 71.7 71.7 71.7 15 Torus 225 72.0 72.0 71.9 71.9 72.0 71.9 71.9 71.9 71.9 71.9 16 Torus 255 72.5 72.5 72.5 72.5 72.5 72.5 72.4 72.5 72.4 72.4 O 17 Torus 3/.5 72.8 72.8 72.7 72.7- 72.7 72.6 72.7 72.7 72.6 72.6 V 18 Mb41 70.4 70.3 70.3 70.3 70.2 70.2 70.2 70.8 70.2 70.8 70.2 70.8 70.3 70.9 19 A2 42 70.9 70.8 70.9 70.9 70.8 70.8 20 Mb 43 71.8 71.8 71.8 71.8 71.8 71.8 71.8 71.8 71.8 71.8 21 Amo $4 74.1 74.1 74.1 74.1 74.1 74.1 74.1 74.1 74.0 74.1 22 kb 15 73.4 73.3 73.4 73.5 73.4 73.3 73.4 73.6 73.5 73.6 23 A2 86 38.6 39.0 38.6 38.3 38.5 38.7 38.8 38.9 39.2 39.2 24 Amb 97 77.7 77.7 77.8 77.6 77.9 78.0 78.1 77.8 77.8 77.1 DEU POINT TE'FERATURE SENSOR LOCATION SCAN 1 SCAN 2 SCAN 3 SCAN 4 SCAN 5 SCAN 6 SCAN 7 SCAN 8 SCAN 9 SCAN 10 04:21 04:35 04:50 05:05 05:20 05:35 05:50 06:05 06:20 06:35 1 El 162 Az 45 '68.6 68.7 68.6 68.8 68.8 68.8 68.7 68.3 68.6 68.7 2 El 100 & 45 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 3 El 100 M 165 76.2 76.2 76.2 76.2 76.2 76.1 76.2 76.2 76.2 76.2 4 El 100 h 285 69.0 69.0 69.1 69.0 69.1 69.1 69.1 69.1 69.1 69.1 5 Torus Ar 45 69.3 69.3 69.3 69.3 69.3 69.3 69.3 69.3 69.2 69.2 6 Torus k 225 69.9 70.0 69.8 70.0 69.9 69.9 69.8 70.0 69.9 69.9 7 Amb D.P. 6.7 6.7 7.2 7.0 -0.0 -0.0 22.4 22.8 22.8 22.7 PRESSURE psia SENSOR LOCATION SCAN 1 SCAN 2 SCAN 3 SCAN 4 SCAN 5 SCAN 6 SCAN 7 SCAN 8 SCAN 9 SCAN 10 04:21 04:35 04:50 05:05 05:20 05:35 05:50 06:05 06:20 06:35 1 64.23 64.23 64.23 64.23 64.22 64.22 64.22 64.22 64.21 64.21 2 64.17 64.16 64.16 64.16 64.16 64.15 64.15 64.15 64.15 64.15 3 14.90 14.90 14.90 14.90 14.89 14.89 . 14.99 14.88 14.88 14.88 4 14.77 14.77 14.77 14.77 14.76 14.76 14.76 14.76 14.76 14.76 i
Appsndix D Shant 2 D
'(V HOPE CREEK GENERATING STATION 31 Dec 1985 CONTAINMENT TErPERATURE SENSOR LOCATION SCM 11 SCM 12 SCM 13 SCM 14 SCM 15 SCM 16 SCAN 17 SCAN 18 SCM 19 SCAN 20 07:05 07:20 07:35 07:50 08:05 08:20 08:35 08:50 09:05 06:50 79.7 79.7 79.7 79.7 79.7 79.7 79.7 79.7 79.7 1 El. 162 Ar 45 79.7 78.8 78.9 78.7 78.9 78.8 78.9 78.8 78.8 78.9 2 El 162 Ar 165 78.9 78.7 78.9 78.7 78.8 78.9 78.9 78.8 78.8 78.8 3 El 162 A: 285 78.8 79.1 79.3 79.2 79.2 79.1 79.1 79.1 79.2 79.2 4 El 122 Az 45 79.2 78.8 78.8 78.8 78.8 78.7 78.8 78.8 78.8 78.7 5 El 122 A: 135 78.7 79.0 79.0 79.1 79.0 79.0 79.0 79.0 79.0 6 El 122 Az 225 79.0 79.2 79.2 79.2 79.2 79.2 79.2 79.2 79.2 79.2 7 El 122 Az 315 79.2 79.2 77.8 77.8 77.8 77.8 77.8 77.8 77.8 77.8 8 El 100 Ar 45 77.8 77.8 75.8 75.8 75.7 75.6 75.5 75.4 75.3 9 El 100 A: 135 75.8 75.8 75.8 77.4 77.5 77.5 77.5 77.6 77.5 77.5 77.4 77.4 10 El 100 Az 225 77.5 78.3 78.3 78.3 78.3 78.3 78.3 78.3 11 El 100 A: 315 78.3 78.3 78.3 72.7 72.6 72.7 72.6 72.7 72.6 72.6 72.5 72.6 12 Torus Az 45 72.6 72.1 72.0 72.0 72.1 72.1 72.2 72.1 72.2 13 Terus ICS 72.2 72.1 71.7 71.7 71.6 71.8 71.7 71.7 71.6 71.8 71.8 71.8 14 Torus 165 15 Torus 225 71.9 71.9 71.9 71.9 71.9 72.0 71.8 71.9 71.9 71.9 16 Torus 285 72.4 72.4 72.4 72.5 72.4 72.4 72.3 72.4 72.3 72.3 17 Torus 345 72.5 72.5 72.6 72.5 72.6 72.5 72.5 72.4 72.4 72.5 p 70.3 70.3 18 M 41 70.3 70.3 70.3 70.3 70.4 70.3 70.2 70.3 19 Amb 12 70.9 71.0 71.1 71.0 70.9 70.9 71.0 70.9 71.0 70.9 20 P-b 43 71.8 71.8 71.8 71.8 71.8 71.8 71.8 71.8 71.8 71.8 21 % ta 74.1 74.1 74.1 74.2 74.1 74.2 74.2 74.2 74.2 74.2 22 Arc 15 73.4 73.4 73.5 73.4 73.4 73.6 73.5 73.0 73.0 73.0 23 Ane 46 39.4 39.3 39.5 39.9 39.8 40.5 40.5 41.1 40.9 42.1 24 Amb 97 75.4 75.1 74.7 74.7 74.7 74.7 76.5 76.9 77.2 77.1 DEW POINT TEMPERATURE SENSOR LCCATICH SCAN 11 SCAN 12 SCAN 13 SCAN 14 SCM 15 SCAN 16 SCAN 17 SCAN 18 SCAN 19 SCAN 20 06:50 07:05 07:20 07:35 07:50 08:05 08:20 08:35 08:50 09:05 1 El 162 Az 45 '68.8 68.8 68.7 68.7 68.8 69.0 ~ 68.7 68.8 68.8 68.3 I El 100 A2 45 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 3 El 100 Az 165 76.2 76.2 76.2 76.1 76.1 76.1 76.1 76.1 76.1 76.1 4 El 100 Az 285 69.1 69.2 69.1 69.1 69.1 69.1 69.1 69.1 69.1 69.1 5 Torus Ar 45 69.2 69.2 69.2 69.2 69.2 69.2 69.2 69.2 69.2 69.2 6 Torus Az 225 69.8 69.7 69.8 69.9 69.8 69.8 69.8 69.8 69.8 69.8 7 Amb 0.P. 22.1 21.9 22.1 20.9 22.0 22.1 22.1 22.2 21.7 19.8 PPESSURE psia SENSOR LOCATIDH SCM 11 SCAN 12 SCAN 13 SCM 14 SCAN 15 SCAN 16 SCM 17 SCM 18 SCAN 19 SCAN 20 06:50 07:05 07:20 07:35 07:50 08:05 08:20 08:35 08:50 09:05 O
V. 1 64.21 64.14 64.21 64.14 64.20 64.13 64.20 64.13 64.20 64.13 64.20 64.13 64.20 64.12 64.20 64.12 64.20 64.12 64.19 64.12 2
3 14.88 14.88 14.00 14.87 14.87 14.87 14.86 14.86 14.06 14.85 4 14.76 14.76 14.75 14.75 14.74 14.74 14.74 14.74 14.73 14.7)
Appnndix D Sheet 3 O
4 / 31 Dec 1985 V
HOPE CPIEK GENERATING STATION CONTAIN:1ENT TEf1PERATURE SENSOR LOCATION SCM 21 SCAN 22 SCAN 23 SCM 24 SCAN 25 SCM 26 SCAN 27 SCM 28 SCAN 29 SCAN 30 09:20 09:35 09:50 10:05 10:20 10:35 10:50 11:05 11:20 11:35 1 EL 162 Az 45 79.7 79.8 77.7 79.7 79.7 79.7 79.7 79.7 79.7 79.7 2 El 162 Az 165 78.8 78.8 78.9 78.9 78.9 78.8 78.9 78.9 78.9 78.8 3 El 162 Az 285 78.8 78.8 78.8 78.8 78.8 78.9 78.8 78.8 78.8 72.7 4 El 122 Ar 45 79.2 79.1 79.2 79.1 79.1 79.3 79.1 79.2 79.2 79.1 5 El 122 A: 135 78.7 78.7 78.8 78.8 76 7 78.7 78.7 78.7 78<7 78.7 6 El 122 Ar 225 79.0 79.0 79.0 79.0 79.0 79.0 79.0 79.0 79.0 79.0 7 El 122 Ar 315 79.2 79.2 79.2 79.2 79.2 79.2 79.2 79.2 79.2 79.2 8 El 100 Az 45 77.8 77.8 77.8 77.8 77.8 77.8 77.8 77.8 77.7 77.8 9 El 100 A: 135 75.3 75.3 75.3 74.8 73.8 73.8 73.8 73.7 73.7 73.7 10 El 100 Az 225 77.5 77.5 77.4 77.5 77.4 77.5 77.5 77.4 77.5 77.5 11 El 100 A: 315 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 12 Torus Az 45 72.5 72.5 72.5 72.5 72.6 72.5 72.5 72.4 72.5 72.5 13 Torus 105 72.1 71.9 72.1 72.1 72.0 72.0 72.0 72.0 72.0 72.0 14 Torus 165 71.7 71.7 71.6 71.6 71.7 71.6 71.6 71.6 71.6 71.5 15 Torus 225 71.8 71.8 71.9 71.9 71.9 71.8 71.8 71.8 71.9 71.9 16 Torus 285 72.3 72.3 72.2 72.3 72.1 72.3 72.2 72.3 72.2 72.3 17 Torus 345 72.5 72.4 72.4 72.3 72.4 72.4 72.3 72.4 72.3 72.4 O 18 % 41 19 Amb 42 70.2 73.9 70.1 70.7 70.1 70.8 70.1 70.8 70.1 70.7 70.1 70.8 70.1 70.8 70.1 70.8 70.1 70.8 70.2 70.7 71.8 20 % 43 71.8 71.8 71.8 71.8 71.8 71.8 71.7 71.8 71.7 21 % 44 74.2 74.1 74.2 74.2 74.2 74.2 74.2 74.2 74.3 74.3 22 M 15 73.0 73.2 73.4 73.6 73.6 73.6 73.7 73.6 73.8 73.7 23 Aab 46 41.7 42.4 43.8 44.1 44.9 45.3 46.5 47.3 48.4 48.3 24 Amb $7 77.0 77.9 76.2 75.9 79.8 75.7 75.8 75.8 75.8 76.1 DEW POINT TEt1PERATUPI SENSOR LOCATION SCAN 21 SCM 22 SCAN 23 SCAN 24 SCAN 25 SCAN 26 SCAN 27 SCAN 28 SCAN 29 SCAN 30 09:20 09:35 09:50 10:05 10:20 10:35 10:50 11:05 11:20 11:35 1 El 162 Ar 45 ~68.5 68.7 68.7 68.8 68.8 68.8 68.8 69.0 68.8 68.8 2 El 100 Ar 45 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 3 El 100 Az 165 76.1 76.1 76.1 76.2 76.2 76.1 76.1 76.1 76.1 76.1 4 El 100 A2 285 69.1 69.2 69.2 69.1 69.1 69.1 69.1 69.1 69.2 69.2 5 Torus Az 45 69.2 69.2 69.2 69.1 69.1 69.1 69.1 69.1 69.1 69.1 6 Torus Az 225 69.8 69.8 69.8 69.8 69.9 69.8 69.7 69.8 69.8 69.7 7 % 0.P. 21.7 20.6 20.3 23.6 26.7 22.5 1.3 19.0 18.5 20.2 PRESSURE psia SENSOR LOCATION SCAN 21 SCM 22 SCAN 23 SCAN 24 SCAN 25 SCAN 26 SCAN 27 SCAN 28 SCAN 29 SCAN 30 09:20 09:35 09:50 10:05 10:20 10:35 10:50 11:05 11:20 11:35 O
(/ 1 64.19 64.19 64.19 64.18 64.18 64.18 64.18 64.18 64.17 64.17 2 64.12 64.12 64.12 64.11 64.11 64.11 64.11 64.10 64.10 64.10 3 14.85 14.85 14.85 14.85 14.85 14.84 14.84 14.83 14.82 14.82 4 14.73 14.73 14.73 14.73 14.72 14.72 14.72 14.71 14.70 14.70
Appendix D Shoot 4
?
\ 31 Dec 1985 HOPE CREEK GENERATING STATION COHTAINMENT TEMPERATURE ,
SENSOR LOCATION SCAN 31 SCAN 32 SCAN 33 SCAN 34 SCAN 35 SCAN 36 SCAN 37 SCAN 38 SCAN 39 SCAN 4 12:20 12:35 12:50 13:05 13:20 13:35 13:50 14:05 11:50 12:05 79.6 79.7 79.7 79.7 79.7 79.7 79.7 79.6 79.7 1 EL 162 Az 45 79.7 78.9 78.9 78.8 78.8 78.8 78.8 78.9 78.9 2 El 162 Ar 165 78.8 78.8 78.9 78.8 78.8 78.8 78.8 78.8 78.7 78.8 78.8 3 El 162 Az 2S5 78.8 79.3 79.2 79.2 79.2 79.2 79.2 79.2 79.2 4 El 122 At 45 79.2 79.2 78.7 78.7 78.7 78.6 78.6 78.7 78.7 78.6 5 El 122 Az 135 78.7 78.7 79.0 79.0 79.0 79.0 79.0 79.0 79.0 79.0 79.0 6 El 122 Az 225 79.0 79.2 79.2 79.2 79.2 79.2 79.1 79.2 79.2 7 El 122 Az 315 79.2 79.1 77.7 77.8 77.8 77.8 77.8 77.8 77.8 77.8 77.8 8 El 100 Az 45 77.8 73.7 73.7 73.7 73.6 73.6 73.7 73.7 73.7 9 El 100 Az 135 73.7 73.7 77.5 77.4 77.6 77.5 77.5 77.4 77.5 77.5 10 El 100 Az 225 77.5 77.5 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.4 11 El 100 Az 315 78.3 78.3 72.4 72.4 72.5 72.5 72.4 72.5 72.4 72.3 72.3 72.4 12 Torus Az 45 72.0 71.9 72.0 72.0 71.9 72.0 71.9 71.9 13 Terus 105 71.9 72.1 71.6 71.6 71.6 71.6 71.6, 14 Torus 165 71.6 71.5 71.6 71.5 71.6 71.9 71.8 71.8 71.8 71.8 71.8 71.8 71.8 15 Tarus 225 71.8 71.9 72.2 72.3 72.2 72.2 72.2 72.1 72.1 72.1 16 Torus 265 72.1 72.2 17 Torus 345 72.3 72.2 72.2 72.3 72.2 72.1 72.2 72.1 72.2 72.1 e- 70.1 A-b 41 73.1 70.3 70.3 70.3 70.1 70.1 70.2 70.1 70.1
( 18 70.8 70.8 70.8 70.8 70.8 19 Amb 42 70.7 70.6 70.6 70.4 70.7
, 20 Aeb $3 71.9 72.0 71.9 71.9 71.8 71.8 71.8 71.8 71.8 71.0 21 A-o 44 74.3 73.9 73.9 73.9 74.4 74.4 74.4 74.4 74.4 74.4 22 Asb 15 73.3 71.5 71.3 71.3 74.1 73.9 74.0 73.9 74.0 74.1 23 Ae6 16 43.3 49.2 49.7 50.2 49.8 49.3 49.3 48.8 48.7 48.2 24 Amb 47 75.9 75.8 79.0 80.0 80.0 77.7 77.7 77.9 76.5 75.0 DEW POINT TEMPERATURE l
SENSOR LOCATION SCAN 31 SCM 32 SCAN 33 SCAN 34 SCAN 35 SCAN 36 SCAN 37 SCAN 38 SCAN 39 SCAN 40 11:50 12:05 12:20 12:35 12:50 13:05 13:20 13:35 13:50 14:05 l
~
1 El 162 Az 45 '68.7 68.7 68.8 68.8 68.7 68.8 68.8 68.9 68.9 68.8 2 El 100 Az 45 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 3 El 100 Az 165 76.1 76.1 76.1 76.1 76.1 76.2 76.1 76.1 76.1 76.1 4 El 100 A2 285 69.2 69.2 69.2 69.2 69.2 69.2 69.2 69.1 69.3 69.3 69.1 69.1 l 5 Toras Az 45 69.1 69.1 69.1 69.1 69.1 69.1 69.1 69.1 6 Tores Az 225 69.7 69.7 69.7 69.6 o9.7 69.7 69.7 69.7 69.7 69.7 7 Amb D.P. 23.3 18.7 20.9 20.8 21.5 18.9 19.6 21.0 20.6 20.6 FRESSURE psia SENSGR LOCAT!0H SCAN 31 SCAN 32 SCAN 33 SCAN 34 SCAN 35 SCAN 36 SCAN 37 SCAN 38 SCAN 39 SCAN 40 11:50 12:05 12:20 12:35 12:50 13:05 13:20 13:35 13:50 14:05
~
,O 64.17 64.17 64.16 64.16 64.16 64.16 64.16 64.16 64.15 64.17 V. 1 64.10 64.10 64.09 64.09 64.09 64.09 64.09 64.09 64.09 64.00 2
14.82 14.83 14.83 14.83 14.77 14.77 14.77 14.77 14.77 14.77 3
14.69 14.69 14.69 14.68 14.68 14.68 14.67 14.67 14.67 14.67 4
App 2ndix D Sheet 5 31 Dec 1985 HOPE CREEK GENERATING STAT!DN CONTAINNENT TEMPERATURE SENSOR LOCATION SCAN 41 SCM 42 SCAN 43 SCAN 44 SCM 45 SCAN 46 SCM 47 SCAN 48 SCAN 49 SCAN 50 15:05 15:20 15:35 15:50 16:05 16:20 16:35 14:20 14:35 14:50 ,
79.7 79.6 79.6 79.6 79.6 79.6 79.6 79.6 1 EL 162 Az 45 79.6 79.6 78.8 78.8 78.8 78.9 78.8 78.9 78.9 78.8 2 El 162 Az 165 78.8 78.8 78.8 78.8 78.8 78.8 78.8 78.8 78.7 78.7 3 El 162 Az 285 78.8 ?8.7 79.2 79.2 79.2 79.1 79.2 79.2 79.2 79.1 4 El 122 Az 45 79.2 79.2 78.6 78.6 78.7 78.6 78.6 78.6 78.6 78.6 5 El 122 Az 135 78.7 76.6 79.0 79.0 79.0 79.0 79.0 79.0 79.0 79.0 6 El 122 Az 225 79.0 79.0 79.2 79.1 79.1 79.1 79.1 79.2 79.2 79.2 7 El 122 Az 315 79.2 79.1 77.8 7).8 77.8 77.8 77.8 77.8 77.8 77.8 77.8 8 El 100 Az 45 77.8 73.6 73.6 73.6 73.6 73.6 73.6 73.6 73.6 9 El 100 92 135 73.6 73.6 77.4 77.5 77.5 77.5 77.6 77.5 77.5 77.5 10 El 100 Az 225 77.5 77.5 78.3 78.3 78.3 78.3 78.3 78.3 78.3 78.3 11 El 100 A: 315 78.3 78.3 72.4 72.4 72.4 72.4 72.3 72.3 72.4 72.3 72.4 12 Torus Az 45 72.3 71.9 71.9 72.0 71.9 72.1 72.0 72.0 71.8 72.0 13 Torus 105 71.9 71.5 71.5 71.6 71.5 71.5 71.6 71.4 71.5 14 Torus 165 71.5 71.5 M.8 71.8 71.8 71.8 71.8 71.7 71.8 71.8 15 Torus 225 71.8 71.8 72.0 72.1 72.0 72.1 72.1 72.1 72.1 72.1 72.1 16 Torus 255 71.9 72.0 72.0 71.9 O 17 Torus 345 72.1 72.0 72.1 72.1 71.9 72.0 72.0 70.2 V 18 Amb $1 19 % 42 70.1 70.8 70.1 70.8 70.2 70.9 70.2 70.9 70.2 70.8 70.2 70.8 70.2 70.9 70.2 70.9 70.2 70.9 70.9 71.9 71.9 71.9 71.9 20 % 43 71.8 71.8 71.8 71.9 71.9 71.9 74.2 74.2 74.3 74.2 74.2 74.2 74.2 74.2 21 N 84 74.3 74.3 74.0 74.0 74.1 74.1 74.2 74.0 73.9 73.9 73.8 73.8 22 Amb 85 43.7 48.9 48.1 47.6 47.6 46.5 47.3 46.0 45.4 45.2 23 Amb $6 75.8 76.0 75.4 77.4 78.0 77.7 77.7 77.9 77.7 78.1 24 Amb 47 DEiJ POINT TEMPERATURE SENSOR LOCATIDH SCAN 41 SCAN d2 SCAN 43 SCAN 44 SCAN 45 SCM 46 SCAN 47 SCAN 48 SCAN 49 SCAN 50 14:20 14:35 14:50 15:05 15:20 15:35 15:50 16:05 16:20 16:35
~68.7 68.8 68.8 68.8 68.8 68.9 '48.9 68.8 68.9 68.9 1 El 162 Az 45 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 2 El 100 Az 45 76.1 76.1 76.1 76.1 76.1 76.1 76.1 76.1 76.1 76.1 3 El 100 Az 165 69.2 69.2 69.2 69.2 69.2 69.3 69.2 69.2 69.1 69.2 4 El 100 Ar 285 69.1 69.1 69.0 69.0 69.0 69.0 69.0 69.0 69.0 69.0 5 Terus Az 45 69.7 69.7 69.7 69.7 69.6 69.7 69.7 69.5 69.6 69.6 6 Torus Az 225 21.2 22.6 24.3 25.2 26.6 26.8 26.5 29.1 13.7 30.7 7 Amb 0.P.
FRESSURE psia SENSOR LOCATION SCAN 41 SCAN 42 SCAN 43 SCAN 44 SCAN 45 SCAN 46 SCAN 47 SCAN 48 SCAN 49 SCAN 50 14:20 14:35 14:50 15:05 15:20 15:35 15:50 16:05 16:20 16:35 s
)
V 64.15 64.15 64.15 64.15 64.15 64.14 64.14 64.14 64.14 64.14 1
64.08 64.08 64.08 64.07 64.07 64.07 64.07 64.07 64.07 64.07 2
14.77 14.78 14.78 14.78 14.78 14.78 14.78 14.79 14.79 14.79 3
14.67 14.67 14.67 14.67 14.67 14.67 14.67 14.67 14.67 14.67 4
Appendix D Sheet 6 O
31 Dec 1985 l
HOPE CREEK GENERATING STATION l CONTAINMENT TEMPERATURE SENSOR LOCATION SCAN 51 SCAN 52 SCAN 53 SCAN 54 SCAN 55 SCAN 56 SCAN 57 SCAN 58 SCAN 59 SCAN 60 16:50 17:05 17:20 17:35 17:50 18:05 18:20 18:35 18:50 19:05 79.6 79.6 79.6 79.6 79.6 79.6 79.6 79.6 79.6 79.6 1 EL 162 Az 45 2 El 162 Az 165 78.8 78.8 78.9 78.9 78.8 78.8 78.2 78.8 78.8 78.8 78.7 78.8 78.7 78.6 78.7 78.7 78.7 78.8 3 El 162 Az 285 78.8 78.9 4 El 122 Az 45 79.2 79.1 79.2 79.1 79.1 79.1 79.2 79.2 79.1 79.2 78.6 78.6 78.6 78.7 78.6 78.6 78.6 78.6 78.6 5 El 122 Az 135 78.6 6 El 122 Az 225 79.0 79.0 79.0 79.0 79.0 79.0 79.0 78.9 79.0 79.0 7 El 122 Az 315 79.1 79.1 79.2 79.1 79.1 79.1 79.2 79.1 79.1 77.1 8 El 100 A2 45 77.8 77.8 77.8 77.8 77.8 77.8 77.8 77.8 77.8 77.8 9 El 100 A: 135 73.6 73.6 73.6 73.6 73.6 73.6 73.6 73.6 73.6 73.6 10 El 100 Az 225 77.5 77.4 77.5 77.5 77.5 77.5 77.5 77.5 77.5 77.5 11 El 100 A: 315 78.4 78.3 78.3 78.3 78.3 78.3 78.3 78.4 78.3 78.3 12 Torus Az 45 72.3 72.4 72.4 72.3 72.4 72.3 72.3 72.3 72.4 72.3 13 Torus 105 72.0 71.9 71.9 71.9 71.9 71.9 71.9 71.9 71.9 71.9 14 Torus 165 71.5 71.5 71.5 71.5 71.4 71.5 71.5 71.6 71.6 71.5 15 Torus 225 71.8 71.8 71.8 71.8 71.8 71.7 71.8 71.8 71.8 71.8 16 Torus 265 71.9 72.0 72.2 72.2 72.1 72.1 72.1 72.1 72.1 71.9 O 17 Torus 345 72.0 71.9 72.0 72.0 71.9 72.1 71.9 72.1 71.9 72.2 d 18 Ae il 19 Amb 12 73.2 71.0 70.2 71.0 70.2 71.0 70.2 71.0 70.3 70.9 70.2 7b.9 70.3 71.0 70.3 71.0 70.2 71.0 70.3 70.9 20 A:b 43 71.9 71.9 71.9 71.9 71.9 71.9 71.9 71.9 71.9. 71.9 21 At to 74.2 74.2 74.2 74.2 74.2 74.2 74.2 74.2 74.2 74.2 22 Amb 15 73.9 73.3 73.8 73.9 73.8 73.8 73.7 73.8 73.9 74.0 23 A4 46 44.6 44.8 44.8 44.7 44.9 45.1 44.9 45.1 44.7 44.7 24 % 47 77.6 77.8 78.0 77.6 78.1 77.7 77.5 77.6 77.5 77.2 DEW POINT TEMPERATURE SENSOR LOCATICH SCAN 51 SCAN 52 SCAN 53 SCAN 54 SCAN 55 SCAN 56 SCAN 57 SCAN 58 SCAN 59 SCAN 60 16:50 17:05 17:20 17:35 17:50 18:05 18:20 18:35 18:50 19:05 1 El 162 Az 45 ~69.0 68.9 68.8 68.9 68.9 68.9 68.9 68.9 68.9 68.4 2 El 100 Az 45 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 3 El 100 Az 165 76.1 76.1 76.1 76.1 76.1 76.1 76.1 76.1 76.1 76.1 4 El 100 Az 285 69.2 69.2 69.2 69.2 69.3 69.2 69.3 69.3 69.3 69.2 5 Torus Az 45 69.0 69.0 69.0 69.0 69.0 69.0 69.0 69.0 69.0 69.0 6 Torus Az 225 69.6 69.5 69.5 69.6 69.7 69.6 69.6 69.6 69.7 69.6 7 Amb D.P. 29.2 30.9 29.9 31.0 32.2 32.3 32.6 32.8 32.9 33.2 PRESSURE psia SENSOR LOCATION SCAN 51 SCAN 52 SCAN 53 SCAN 54 3CAN 55 SCAN 56 SCAN 57 SCAN 58 SCAN 59 SCAN 60 16:50 17:05 17:20 17:35 17:50 18:05 18:20 18:35 18:50 19:05
' [ ,)
l V 1 64.14 64.14 64.13 64.13 64.13 64.13 64.13 64.13 64.13 64.12 2 64.07 64.07 64.07 64.06 64.06 64.06 64.06 64.06 64.06 64.05 3 14.79 14.79 14.79 14.80 14.80 14.80 14.80 14.79 14.79 14.79 4 14.67 14.67 14.67 14.67 14.67 14.67 14.67 14.67 14.67 14.67 l
- Appendix D Sheet 7 O 31 Dec 1985 HOPE CREEK GENERATING STATION CONTAINMENT TEMPERATURE SENSOR LOCAi!0N SCAN 61 SCAN 62 SCAN 63 SCAN 64 SCAN 65 SCAN 66 SCM 67 SCAN 68 SCAN 69 SCAN 70 19:35 19:50 20:05 20:20 20:35 20:50 21:05 21:20 21:35 19:20 79.6 79.7 79.6 79.6 79.6 79.6 79.6 79.6 79.6 79.6 1 EL 162 Az 45 78.8 78.7 78.8 78.8 78.8 78.7 78.7 78.8 78.8 2 El 162 Az 165 78.8 78.7 78.9 78.8 78.7 78.8 78.8 78.7 78.7 78.8 3 El 162 Az 285 78.8 79.2 79.2 79.1 79.3 79.1 79.2 79.1 79.2 79.1 4 El 122 Ar 45 79.2 78.6 78.6 78.6 78.6 78.7 78.6 78.6 78.6 78.6 5 El 122 Az 135 78.6 79.0 79.0 79.0 79.0 79.0 79.0 79.0 79.0 6 El 122 Az 225 79.0 79.0 79.1 79.1 79.1 79.2 79.1 79.1 79.2 79.1 7 El 122 Az 315 79.1 79.2 77.8 77.8 77.8 77.8 77.8 77.8 77.8 77.8 8 El 100 Ar 45 77.8 77.8 9 El 100 A: 135 73.5 73.6 73.4 73.4 73.4 73.4 73.4 73.4 73.4 73.4 77.5 77.5 77.5 77.6 77.5 77.5 77.6 10 El 100 Ar 225 77.5 77.5 77.5 78.4 78.4 78.3 78.4 78.4 78.3 11 El 100 A: 315 78.3 78.3 78.4 78.3 12 Torus Ar 45 72.3 72.2 72.3 72.3 72.3 72.4 72.4 72.4 72.3 72.4 13 Torus 105 71.9 72.1 71.9 71.9 71.8 71.9 71.9 71.8 72.0 71.9 14 Torus 165 71.5 71.5 71.5 i" .5 71.5 71.5 71.5 71.4 71.5 71.4 15 Torus 225 71.9 71.7 71.P 11.8 71.8 71.8 71.7 71.7 71.8 71.8 16 Torus 285 72.1 72.0 72.0 72.0 72.1 72.0 72.0 72.2 71.9 71.8
[D 17 Torus 345 72.0 72.0 71.9 72.2 72.0 72.1 72.0 72.0 72.0 72.0 V 18 % 41 70.2 70.2 70.3 70.3 70.2 70.3 70.2 70.3 70.9 70.2 70.9 70.2 70.9 19 Amb $2 70.9 70.9 71.0 70.9 71.0 70.9 71.0 20 A2 83 71.9 71.9 71.9 71.9 71.9 71.9 71.9 71.9 72.0 71.9 21 Ae le 74.2 74.2 74.2 74.2 74.2 74.2 74.2 74.2 74.2 74.2 22 Amb $5 73.9 74.0 73.9 73.9 73.9 73.9 73.9 73.8 73.9 74.0 23 Aab $6 44.4 44.8 44.7 45.1 44.8 44.2 44.1 44.0 44.3 44.6 24 Amb $7 77.7 77.7 82.3 83.9 80.7 78.4 77.9 77.9 77.6 78.2 DEU POINT TEMPERATURE SENSOR LOCATION SCAN 61 SCAN 62 SCAN 63 SCAN 64 SCAN 65 SCAN 66 SCAN 67 SCAN 68 SCAN 69 SCAN 70 19:20 19:35 19:50 20:05 20:20 20:35 20:50 21:05 21:20 21:35 1 El 162 Az 45 ~68.9 68.9 68.9 69.0 68.9 68.9 68.9 69.1 69.0 69.3 2 El 100 Az 45 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 3 El 100 Ar 165 76.1 76.1 76.1 76.1 76.1 76.1 76.1 76.1 76.1 76.1 4 El 100 Az 285 69.2 69.2 69.4 69.3 69.3 69.3 69.4 69.3 69.3 69.2 5 Torus Az 45 69.0 69.0 69.0 69.0 69.0 69.0 69.0 69.0 69.0 69.0 6 Torus Az 225 69.6 69.5 69.6 69.6 69.6 69.6 69.6 69.6 69.6 69.5 7 bb 0.P. 33.7 34.4 34.9 35.2 35.4 36.7 36.0 36.9 36.8 37.2 FPESSURE psia SENSOR LOCATION SCAN 61 SCAN 62 SCAN 63 SCAN 64 SCAN 65 SCAN 66 SCAN 67 SCAN 68 SCAN 69 SCAN 70 19:20 19:35 19:50 20:05 20:20 20:35 20:50 21:05 21:20 21:35
!m\
\ J M. 1 64.12 64.12 64.05 64.12 64.05 64.17 64.05 64.12 64.06 64.12 64.06 64.12 64.05 64.11 64.05 64.11 64.05 64.11 64.04 j
1 2 64.05 3 14.79 14.79 14.79 14.79 14.79 14.79 14.79 14.79 14.79 14.79 4 14.67 14.67 14.67 14.67 14.67 14.67 14.67 14.67 14.67 14.67
Appendix D Sheet 8 O
V 31 Dec 1985 H0FE CkEEK GENERATING STATION CONTAINMENT TEMPERATURE SENSOR LOCATION SCAN 71 SCAN 72 SCAN 73 Mn 74 SCAN 75 SCAN 76 SCAT 7' SCM 78 SCAN 79 SCAN 80 22:05 22:20 22:35 22:50 23:05 23:.1 23:35 23:50 00:05 21:50 79.6 79.6 79.6 79.6 79.6 79.6 79.6 79.6 79.6 1 EL 162 Az 45 79.6 78.9 79.8 78.8 78.9 78.8 78.7 78.8 78.8 78.8 2 El 162 Ar 165 78.9 78.8 78.7 78.8 78.8 78.8 78.7 78.7 78.8 78.7 3 El 162 Az 285 78.7 79.2 79.2 79.2 79.2 79.1 79.2 79.1 79.2 79.2 4 El 122 Az 45 79.2 5 El 122 Az 135 78.6 78.6 78.6 78.5 78.6 78.7 78.6 M.6 78.6 78.6 79.0 79.0 79.0 79.0 79.0 75 .0 79.0 79.0 6 El 122 Az 225 79.0 79.0 79.1 79.1 79.1 79.1 79.1 79.1 79.2 79.1 7 El 122 Az 315 79.1 79.1 77.8 77.8 77.8 77.8 77.8 77.8 77.8 77.8 77.8 8 El 100 Az 45 77.8 73.4 73.4 73.4 73.4 73.4 73.4 73.4 73.1 9 El 100 Az 135 73.4 73.4 77.5 77.5 77.5 77.6 77.6 77.6 77.5 77.6 10 El 100 Az 225 77.5 77.5 78.3 78.3 78.3 78.4 78.4 78.3 78.4 78.3 11 El 100 Az 315 78.4 73.3 72.3 72.3 72.3 72.2 72.3 72.3 72.3 72.3 72.2 12 Torus Ar 45 72.4 13 Torus 105 71.8 71.9 71.9 71.8 71.9 71.8 71.9 71.8 71.8 71.8 14 Torus 165 71.5 71.5 71.5 71.5 71.4 71.5 71.6 71.5 71.4 71.5 15 Torus 225 71.7 71.7 71.8 71.8 71.8 71.8 71.8 71.8 71.8 71.8 16 Torus 265 72.0 72.0 72.1 72.0 72.0 72.0 72.0 72.0 72.1 72.0 17 Torus 345 72.1 72.1 72.0 72.1 72.2 72.0 72.1 72.1 72.1 p 72.1 70.2 70.2 70.2 70.2 70.2 18 Amo il 70.2 Q 19 A-b 12 70.2 70.9 70.2 71.0 70.2 70.9 70.2 70.9 70.9 70.9 70.9 10.9 70.9 70.9 20 Art 43 71.9 71.9 71.9 71.9 71.9 71,9 72.0 71.9 71.9 71.9 21 Aro 44 74.2 74.2 74.2 74.2 74.2 74.2 74.2 74.3 74.2 74.2 22 Arb 15 74.1 74.0 74.1 74.0 74.1 74.1 74.0 74.0 74.0 74.1 23 rab 46 44.7 44.7 44.9 44.9 45.3 45.7 45.5 45.6 45.7 45.8 24 feb 87 78.0 77.9 77.7 77.7 77.7 78.0 77.7 77.8 70.0 77.4 DEU POINT TEMPERATURE SENSOR LOCATION SCAN 71 SCM 72 SCM 73 SCAN 74 SCAN 75 SCAN 76 SCAN 77 SCM 78 SCAN 79 SCAN 80 21:50 22:05 22:20 22:35 22:50 23:05 23:20 23:35 23:5C 00:05 1 El 162 Az 45 '68.9 69.0 69.0 69.0 68.9 69.0 "69.0 68.9 69.0 69.1 2 El 100 Az 45 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 3 El 100 Az 165 76.1 76.1 76.1 76.2 76.1 76.2 76.1 76.1 76.1 76.2 4 El 100 Az 285 69.3 69.3 69.3 69.3 69.3 69.4 69.5 69.3 69.4 69.3 5 Torus 42 45 69.0 69.0 69.0 69.0 69.0 69.0 69.0 69.0 69.0 69.0 6 Torus Ar 225 69.6 69.6 69.7 69.6 69.4 69.7 69.6 69.6 69.7 69.6 7 Amb D.P. 37.1 37.1 37.5 37.2 37.5 37.5 37.6 37.7 37.7 37.4 FRESSURE psia SENSOR LOCATION SCAN 71 SCAN 72 SCAN 73 SCAN 74 SCAN 75 SCAN 76 SCAN 77 SCAN 78 SCAN 79 SCAN 80 21:50 22:05 22:20 22:35 22:50 23:05 23:20 23:35 23:50 00:05
- o i 2
64.u 64.04 64.11 64.04 64.11 64.04 64.10 64.03 64.10 64.03 64.10 64.03 64.10 64.03 64.10 64.03 64.u 64.03 64.10
- 4.03 l
14.79 14.79 14.79 14.79 14,'h 14.79 !
3 14.79 14.79 14.79 14.79 14.67 14.67 14.67 14.67 14,67 14.67 14.67 14.67 14.67 l 4 14.67
Appendix D Sheet 9 1 Jan 1986 V
HOPE CREEK GENERATING STATION CONTAINMENT TEMPERATURE SENSOR LOCATION SCAN 81 SCAN 82 SCAN 83 SCAN 84 SCAN 85 SCM 96 SCAN 87 SCM 88 SCAN 89 SCAN 90 00:50 01:05 01:20 01:35 01:50 02:05 02:20 02:35 00:20 00:35 79.6 79.6 79.6 79.6 79.6 79.6 79.6 79.6 1 EL 162 Az 45 79.6 79.6 78.8 78.8 78.8 78.8 78.8 78.8 78.7 78.8 2 El 162 Az 165 78.8 78.9 78.7 78.7 78.7 78.7 78.7 78.7 78.7 78.7 3 El 162 Az 285 78.6 78.7 79.2 79.2 79.1 79.2 79.3 79.2 79.2 79.3 4 El 122 Az 45 79.1 79.2 78.6 78.5 78.6 78.6 78.6 78.6 78.6 78.6 5 El 122 Az 135 78.6 78.6 79.0 78.9 78.9 78.9 79.0 79.0 79.0 79.0 6 El 122 Az 225 78.9 79.0 79.1 79.1 79.1 79.1 79.1 79.1 79.1 79.1 7 El 122 Az 315 79.1 79.1 77.8 77.8 77.8 77.8 77.8 77.8 77.8 77.8 77.8 8 El 100 Az 45 77.8 73.1 73.1 73.1 73.1 73.1 73.1 73.1 73.1 9 El 100 Az 135 73.1 73.1 77.6 77.6 77.6 77.5 77.6 7,.5 77.6 77.6 77.6 10 El 100 Az 225 77.5 78.4 78.4 78.3 78.3 78.3 78.3 78.4 78.4 78.4 11 El 100 Az 315 78.4 72.3 72.4 72.3 72.4 72.4 72.3 72.2 72.4 72.5 12 Torus Ar 45 72.3 72.0 71.8 71.8 71.8 71.9 71.8 71.9 71.9 71.8 71.8 13 Torus 105 71.4 71.4 71.4 71.4 71.4 71.4 71.4 71.5 71.4 71.4 14 Torus 165 71.7 71.8 71.7 71.7 71.7 71.8 71.8 71.7 71.7 15 Torus 225 71.8 72.0 72.0 71.9 72.1 71.9 72.1 72.0 71.9 16 Torus 285 71.9 72.0 72.2 72.1 72.1 72.2 72.0 72.2 72.0 72.0 72.2 17 Torus 345 72.2 70.2 70.1 70.2 70.2 70.3 70.3 70.2 70.2 70.2
) 18 A2 il 70.2 70.9 70.9 70.9 70.9 70.9 70.9 19 Ac #2 73.9 70.9 70.9 70.9 20 A@ 43 71.9 71.9 71.9 71.9 71.9 71.9 71.9 71.9 72.0. 71.9 74.3 74.3 74.3 74.3 74.3 74.3 74.3 74.2 21 A .b 94 74.2 74.2 74.0 74.1 74.2 74.1 74.1 22 A2 15 74.1 74.1 74.2 74.1 74.1 23 A-6 16 45.6 45.3 45.2 45.2 45.8 45.6 45.5 45.7 45.5 45.0 24 Amb 87 77.7 77.4 77.5 77.8 77.4 77.8 77.4 77.1 77.5 77.8 DEU PalNT TEMPCRATURE SENSOR LOCAT!DN SCAN 81 SCAN 62 SCM 83 SCAN 84 SCAN 85 SCAN 86 SCAN 87 SCAN 88 SCAN 89 SCAN 90 00:20 00:35 00:50 01:05 01:20 01:35 01:50 02:05 02:20 02:35
^
'68.9 69.0 69.1 69.4 -69.0 69.0 68.9 69.1 69.0 69.0 1 El 162 Ar 45 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 2 El 100 Az 45 76.2 76.2 76.1 76.2 76.1 76.2 76.1 76.2 76.2 76.2 3 El 100 Az 165 4 El 100 Az 285 69.4 69.3 69.4 69.4 69.4 69.3 69.4 69.4 69.5 69.4 5 Torus Az 45 69.0 69.0 69.0 69.0 69.0 69.0 69.0 69.0 69.0 69.0 6 Torus Az 225 69.5 69.6 69.5 69.7 69.6 69.5 69.6 69.5 69.5 69.7 37.3 37.2 37.2 37.4 37.4 37.3 37.2 37.3 37.3 37.2 7 Amb D.P.
PRESSUPI ps:a SENSOR LOCATION SCAN 81 SCAN 82 SCAN 83 SCAN 84 SCAN 85 SCAN 86 SCAN 87 SCAN 88 SCAN 89 SCAN 90 00:20 00:35 00:50 01:05 01:20 01:35 01:50 02:05 02:20 02:35 (2
\.
1 2
64.09 64.02 64.09 64.02 64.09 64.02 64.09 64.02 64.09 64.02 64.09 64.02 64.09 64.02 64.08 64.02 64.08 64.01 64.08 64.01 14.78 14.79 14.79 14.79 14.79 14.79 14.79 14.79
} 14.78 14.78 14.67 14.67 14.66 14.66 14.66 14.66 14.67 14.67 14.67 14.67 4
I
Appendix D Sheet 10 x> .
1 lan 1986 HOPE CREEK GENERATING STATION CONTAlkMENT TEMPERATURE SENSOR LOCATION SCAN 91 SCAN 92 SCAN 93 SCAN 94 SCAN 95 SCAN 96 SCAN 97 SCAN 98 SCAN 99 03:05 03:20 03:35 03:50 04:05 04:20 04:35 02:50 79.6 79.5 79.6 79.6 79.6 0.0 0.0 1 EL 162 Az 45 79.6 79.6 79.6 78.8 78.8 78.8 78.9 78.8 0.0 0.0 2 El 162 Az 165 78.8 78.8 78.8 78.8 78.7 78.8 78.7 78.8 0.0 0.0 3 El 162 Az 285 78.6 78.7 78.7 79.3 79.3 79.3 79.3 79.3 0.0 0.0 4 El 122 Ar 45 79.2 79.4 79.3 78.6 78.6 78.6 78.6 78.6 78.7 0.0 0.0 5 El 122 Az '.J 78.6 78.6 78.9 79.0 79.0 79.0 79.0 0.0 0.0 6 El 122 Az 225 79.0 79.0 78.9 79.1 79.2 79.2 79.1 79.1 0.0 0.0 7 El 122 Az 315 79.1 79.1 79.1 77.8 77.8 77.8 77.8 77.8 0.0 0.0 8 El 100 Az 45 77.8 77.8 77.8 73.1 73.1 73.1 73.1 73.1 0.0 0.0 9 El 100 Az 135 73.1 73.1 73.1 77.6 77.6 77.6 77.6 77.6 0.0 0.0 10 El 100 Az 225 77.5 77.5 77.6 78.3 78.4 78.4 78.4 78.3 78.3 0.0 0.0 11 El 100 Az 315 78.4 78.4 72.3 72.3 72.3 72.4 72.3 72.4 0.0 0.0 12 Torus Az 45 72.4 72.4 71.8 71.8 71.9 71.8 71.8 71.8 0.0 0.0 13 Torus 105 71.8 71.9 71.4 71.5 71.4 71.4 71.4 71.4 71.5 0.0 0.0 14 Torus 165 71.4 71.8 71.7 71.7 71.8 71.7 71.7 71.7 0.0 0.0 15 Torus 225 71.8 71.8 71.9 72.0 72.1 72.1 72.1 0.0 0.0 16 Torus 285 72.0 71.9 72.0 72.2 72.0 72.2 72.0 72.2 72.2 0.0 0.0
) 17 Torus 345 72.1 70.2 79.2 70.2 70.2 70.2 0.0 0.0 d 18 Amb 41 70.2 70.2 70.2 70.9 70.9 71.0 70.9 70.9 70.9 70.9 0.0 0.0 19 Amb 12 70.9 71.9 72.0 71.9 71.9 71.9 71.9 71.9 71.9 0.0 - 0.0 20 Amb 43 74.3 74.3 74.3 74.3 74.2 74.2 74.2 0.0 0.0 21 Amb to 74.3 74.2 74.2 74.2 74.0 74.1 74.1 74.2 0.0 0.0 22 Amb 15 74.2 44.3 44.2 43.5 43.2 43.1 43.0 43.7 0.0 0.0 23 Amb 96 44.3 77.7 77.4 76.8 76.1 75.6 76.1 75.6 0.0 0.0 24 Amb 47 77.6 DEW POINT TEMPERATURE SENSOR LOCATION SCAN 91 SCAN 92 SCAN 93 SCAN 94 SCAN 95 SCAN 96 SCAN 97 SCAN 98 SCAN 99 SCAN 100 02:50 03:05 03:20 03:35 03:50 04:05 04:20 04:35
~
69.0 69.0 69.0 69.1 69.0 69.0 0.0 0.0 1 El 162 Az 45 '69.1 69.0 76.4 76.4 76.4 76.4 76.4 76.4 76.4 76.4 0.0 0.0 2 El 100 Az 45 76.2 76.2 76.2 76.2 76.2 76.2 76.2 0.0 0.0 3 El 100 Az 165 76.2 69.4 69.5 69.4 69.4 69.5 69.4 69.4 69.4 0.0 0.0 4 El 100 Az 285 69.0 69.0 69.0 69.9 69.0 69.0 69.0 69.0 0.0 0.0 5 Torus Az 45 69.5 69.6 69.4 69.5 69.6 69.5 69.5 69.5 0.0 0.0 6 Torus Az 225 36.9 36.3 35.9 35.7 35.3 35.2 35.0 0.0 0.0 7 Amb D.P. 37.3 PRESSURE osia SENSOR LOCATICN SCAN 91 SCAN 92 SCAN 93 SCAN 94 SCAN 95 SCAN 96 SCAN 97 SCAN 98 SCAN 99 SCAN 100 03:50 04:05 04:20 04:35 m 02:50 03:05 03:20 03:35 64.08 64.08 64.07 64.07 64.07 64.07 64.07 0.00 0.00 1 64.08 64.01 64.01 64.01 64.01 64.00 64.00 64.00 0.00 0.00 2 64.01 14.80 14.80 14.30 14.80 14.81 14.81 14.81 0.00 0.00 3 14.79 14.67 14.67 14.67 14.67 14.68 14.68 14.68 0.00 0.00 4 14.67
O O O Appendix E 83 <-
82.5 - RTD No.1 Located at EL 162 Rz 45 82 -
81.5 -
81 -
h.
m
$ 80.5 -
I w
- E 80 -
i 3
x 79.5 w
- a_
i I pg _
- w l l--
l 78.5 -
I I I I I I I I
! 78 i - e o e e o e e
! m m m m m m m m e a m m m m ~ v
- s -* ~ ~ " N s e I e t TIME hour 31 Dec 1985
O .
O O Appendix E Sheet 2 83 -
HOPE CREEK ILRT RTD No.2 Located at El 162 Rz 165 82.5 -
82 -
81.5 -
, 81 -
L.
c)
-E 80.5 -
. W N 80 -
- D H
l E 79.5 -
w Q.
i E 79 l 78.5 -
I I I I I I I I 78 s e s
~ ca ca e a N N N N N N CU N
a m w m N ~ w w ~ ~ ~ ~ N S G G
S l
3 i TIME hour 31 Dec 1985
O O o Appendix E Sheet 3 HOPE CREEK ILRT 83 -
82.5 - RTD No.3 Located at El 162 Rz 285 82 -
81.5 -
4 81 -
- b_
cn l $ 80.5 -
W E 80 -
i a F-l E 79.5 -
w
.! D.
I E 79 N '
i 78.5 -
I I I I I I I I 78 ca e S ca ca ca ca nJ N N N N N cu tu " v ca m to cn N
- e s-* " ~ " N S S
- c3 l
G F
TIME hour 31 Dec 1985 I . _ _ _ _ - _ _ _ . _ _ - . . _ _ _ _ _ _ - _
i I
Appendix E Sheet 4
! 80 -
l 79.5 - RTD No.4 Located at El 122 Rz 45 79 -
78.5 -
l 78 -
u.-
m
$ 77.5 -
- w 1
a 77 - -
F E 76.5 -
w n.
- y 76 -
75.5 -
I I I I I I I I 75
~ o c3 o o ca e a N N cu tu tu tu N cu e ca m m m tu - e
! O " ~ ~ ~ N S G
! 8 TIME hour 31 Dec 1985 i
O O O Appendix E Sheet 5 80 -
HOPE CREEK ILRT 79.5- - RTD No.5 Located at El 122 Rz 135 79 -
~
78.5 -
78 -
- u. -
c)
-@ 77.5 -
w tr 77 -
a F
- E 76.5 -
Q.
] 76 -
V 75.5 -
I I I I I '
' I I 75 s e s G
~ s e e N OJ N N N N N N
- T G U1 (D 01 N y
m m ~ ~ N G G O
G i
i TIME hour 31 Dec 1985
l O
O O Appendix E Sheet 6 HOPE CREEK ILRT 80<-
79.5- - RTD No.6 Located at El 122 Rz 225 79 78.5 -
78 - -
h.-
m
- E 77.5 -
w n' 77 -
a
- E E 76.5 -
w
! Q.
[ 76 -
- H i 75.5 -
I I I I I I I I 75 e a e
- - e o e s (V N (u Cu N (M (M I (u cn - e e e m to tu G G
- ,- - - N
- G O
! TIME hour 31 Dec 1985 i
O O 'd
^PPendh E HOPE CREEK ILRT Sheet 7 80 -
79.5 - RTD No.7 Located at El 122 Rz 315
~- _-_
79 t-i 78.5 -
78 -
w-oi
$ 77.5 -
1 w tr 77 -
a V-E 76.5 -
w (L
r 76 -
w F
75.5 -
l '
I ' ' '
I I 75 o e e e e s i - e N N N N N N m N m N ~ v l
y e m m ~ N s s
- m ~ m l 9 e
i TIME hour 31 Dec 1985
O O O Appendix E 8"*** 8 HOPE CREEK ILRT 80<-
79.5 - RTD No.8 Located at El 100 Rz 45 79 -
78.5 -
78 --
=- -
w-m 1
y 77.5 -
W T 77 -
a
, I--
E 76.5 -
w
- Q.
y 76 -
75.5 -
i I I I I I i i I 75 e e o e e
- e e N N N N N N N ~ v N
e m m m N-o G
, - - m s - ,-
ca i
l TIME hour 31 Dec 1985 l
1 O O O Appendix E 80 -
HOPE CREEK ILRT sweet y i
79 _ RTD No.9 Located at El 100 Rz 135 78 -
t 77 - -
76 -
c)
$ 75 -
i % 74 - -
1 a -
t -
l--
l E 73 --
4' w l
[1.
6 72 -
i r
l 71 -
l i i I i i i 1 J i 7g
" e e o e a s G i
N N N N (M ni N N 03 N " t
< G M ID G
G " " " " N G I G TIME hour 31 Dec 1985
O O O Appendix E 80<-
79.5- -. RTD No.10 Located at El 100 Rz 225 79 -
78.5 -
78 -
77.5 -
w g 77 --
F E 76.5 -
W n.
y 76 -
F -
75.5 -
I I I I I I I I 75
-- e cD ca cc (9 s to N cu N N tu N N N "
$ 3 C $ $ 5 &
TIME hour 31 Dec 1985
-_ _ _ _ _ . _ _ . . _ _ - _ _ . . . . .- - - - . . .-. . _ _ . = ..
O ~
O O Appendix E Sheet 11 80<-
79.5 - RTD No.11 Located at El 100 Rz 315 79 -
78.5- -
- ~
78 -
L m '
j 77.5 -
w tr 77 -
a w
76.5- -
a.
y 76 - - ,
H 75.5 -
' I -I I I I I I 75
~ G G G G G G S N N N N N N N N G M 01 N " V !
v " "
CD
" " N S S Q ,
G TIME hour 31 Dec 1985 ,
O O ~O Appendix E Sheet 12 HOPE CREEK ILRT t 75 -
74.5 - RTD No.12 Located at Torus Rz 45 74 -
- 73.5 -
l t
73 - -
L.
en l $ 72.5 -
p
, El i 2 72 -
- a I--
l E 71.5 -
! w i a.
r 71 -
i w l H
! 70.5 -
i 70 I -- d---- I I o a o e S S
- e N N N N N N N N - e a m m cn N e + e m ~ N G G y
i G
! TIME hour-31 Dec 1985 1
i k . . , . . . . - _ . . . , _ . . . . . _ . _ , .m. _ - . < . - - _ . . . . __ . - _ _ _ _ _ _ _ _ _
O O O Appendix E Sheet 13 HOPE CREEK ILRT 75 -
74.5 - RTD No.13 Located at Torus 105 74 -
i 73.5 -
i 73 -
h.
m
] 4 72.5 -
72 - %
H '
Ld 71.5 -
O 71 ~
4
{
y- :
70.5 -
I I l f I -I i r i~ I _
?O '
o e G S
- o e a N N N N N N N
- m m w m N ~ *
, o- - - - N S S g ,
1 O i
TIME hour 31 Dec 1985
\
4 Appendix E I
73 _
HOPE CREEK ILRT l 74,$ - RTD~No.14 Located at Torus 185 e
'?4 --
l 73.5 --
i
! 73 i -
t ,
en .
l -E '7 2 . 5 ' -
- w x 79 -
71.5 -
M y
! a.
r 7g _.
w ,
F- 1 70.5h i 70 --- I I I I I I I J
- - o a a a o a e
- m m m m m m m m w a m to cn su ~ w
- O - - - - eu e s G
i TIME hour 31 Dec 1985 i
- _ _ _ - _ _ _ - _ _ _ - - _ _ - _ . _ - - - _ _ - - - _ _ - _ - ~ _ _ _ _ _ - - - - - - - - . _ - -
O O o Appendix E Sheet 15 HOPE CREEK ILRT .
75 -
74.5 - RTD No.15 Located at Torus 225 74 -
73.5- -
73 -
L.
m ,
-E 72.5- -
w
% wg E 71.5 -
w CL y 71 -
F '
70.5 - ,
I I ' '
-J ' I I 70 -
e ca ca c3 e ca ca N N t\1 N N tu m N - v e m to cn cu -
m ~ ~ ^ N G G O
G TIME hour 31 Dec 1985 -
Appendix E HOPE CREEK ILRT 75 -
l 74.5 - RTD No.16 Located at Torus 285 74 -
73.5- -
73 -
h.
co a
F-a E 71.5 -
i I
w Q.
- y 71 -
F-70.5 -
i I - I- I I '
I I- - - =
70 G G G G
- ts) G 153 N N CM N N N N - e N m m cn N e G -< *< N Q G
.-e e<
l 9 ,
G l
t I
l TIME hour 31 Dec 1985
Appendix E .
Sheet 17 HOPE CREEK ILRT 75 -
74.5 - RTD No.17 Located at Torus 34'5
- 74 -
l 73.5 -
73 -
L m
- 72.5 . -
E 72 -
a H
E 71.5- -
- La
, Q. ,
71 -
i 6
w i
70.5 ,-
i i i i I L i 1 70 e a G S
~ a e a N N N N N g 3 $ $ $ $ 5 $
h G
l i .
1 i
- TIME hour 31 Dec 1985
-. ---- __ + e ..-e-- - e . .- e . - . _ . _ . _ _ _ _ _ _ _ _ _ _ -__-
O O O
$ECE*i!"
HOPE CREEK ILRT 70 -
69.5- - D.P. No.1 Located at El 1G2 Rz 45 69 -
68.5 - -
I G8 -
u.
, m l $ 67.5 -
W tr 87 -
, a F
l E B6.5 -
i w D-y
- 66 -
i F
i 65.5 -
I I I I l -
1 I l 65 e e e e e
- e e (U N OJ N
- N N N
- v N 01 N T G f9
.-e
(.D m .-< m S O O
G i
1 i
' TIME hour 31 Dec 1985 i
\
Appendix E 80 -
79.5 - D.P. No.2 Located at El 103 Rz 45 79 -
78.5 -
i i
78 -
i h.
oi
-E 77.5 -
]
w x 77 -
, a 1' F-E 76.5 -
w Q.
y 76 -
4 F-75.5 -
I I I I I I I I
- 75
. - ca e ca o ca e e I
fu (U N N N N N N j v Q F1 (O CD N
- v
, G ~ ~ ~ ~ N G G G
I j .
TIME hour 31 Dec 1985 l
O O O Appendix E Sheet 20 HOPE CREEK ILRT 80 p 79.5 - D.P. No.3 Located at El 100 Rz 165 79 -
78.5 -
78 -
u.
m
.$ 77.5-- -
w tr 77 ' -
3 F-
- E 76.5 -
w D. -
r 76 '
w F-i 75.5 -
1 I I I l I I I I
. 75 -
! ~ o e a e e e e
! nj N RI N OJ N N
,r a m to N, o N ~ w O ~ ~ ~ ~ N O s l G 4
TIME hour 31 Dec 1985 i ,
O O O Appendix E Sheet 21
,g _ HOPE CREEK ILRT 69 5 - D.P. No.4 Located at El 100 Rz 285 N 69 68.5 -
68 -
u.
m
$ 67.5 -
\
w
, E 67 -
, o i &
! E 66.5 -
4 w I Q.
j { 66 -
! H 65.5 -
I I-- I I I -- I I I 65
, - ca e o e e e e N N N N N N N N w a m to en N ~ w G .-* ~ ~ ~ N G G G
i i
! TIME hour 31 Dec 1985
O O .o.
Appendix E Sheet 22 HOPE CREEK ILRT 73 -
72.5 - D.P. No.5 Located at Torus Rz 45
- 72 - -
71.5 - -
4 71 - -
- h.
- m j y 78.5 -
- w
- m 70 - -
a i F-
! E 69.3 - -
w % -
1 -- -
r
! w 69 -
i F-3 68.5 -
I I - I- -
I --- I- '=
68 o o o a l - o a o N N N N N N N - e N, a m m m N o
g - - - - N o j
t a i
4 I TIME hour 31 Dec 1985 i
O O -
O Appendix E
. Sheet 23 i
73 -
HOPE CNEEK ILRT l 72.5 - D.P. No.6 Located at Torus Rz 225 i
72 - -
i
! 71.5- -
- i. 71 ' -
g.
i m j j 70.5 -
! w E 7 0 <'~
i 3 69.5 - -
w
[1.
I w 69 -
1 1--
68.5 - -
l I I d -' ' I ' -----
68 m
- e c9 c0 cD N
c0 N N cD N
m m N N Q m (D 01 N --' T i e a ~ ~ N G S l
g -
1 G
I TIME hour 31 Dec 1985 i
L_-- __ __ _ _ _ _ _ _ _ _ _ _ _ _ . _ _ _ _ _ _ _ . _ _ _ _ . . _ _ _ _ _ _ _ _ _ ------_ __--_
j T 0290
( I ]
C) , I l
$5 ; 0210 5t s 2: > I
<m J j
^
l- 0222 2 / .
i /
x '
N 5 / 026I
= j !
F E
Ia /
/ e
~
-J e 0291 H f o o e
- I a l O Fd i ' -
Ld -
I -
02EI s.
E w ! S U $ l I m / w Ld m I a y / -
0201 p
! o .
/
l T y J J
l w l r /
l 3 /
04510 tc t
e /
8 /
I I I I I I I /1 I i 12b8 in in e in m in cu in - in v
- T
- M = N = * = CD to e e v e v . v . v . I to v. to e to e to e to y to co to co co i l
1 HISd l
Appendix F Sheet 1
.O 1 Jan 1986 HOPE CREEK GENERATING STATION RECALC-VERIFICATION TEST APE!ENT CONTAIRENT
!%SS LEAK RATE SUPERIMPOSED SCAN Tite PRESS TEff TENP DEW PT PRESS Lba Lbs/Hr 4/ Day Lbs/Hr 4/ Day Scfm No. Hour Psia DegF DegF DegF Psia 97105 0.000 0.000 19.026 .470 4.269 1 08:11 14.9 41.7 75.3 69.3 63.98 97100 0.000 0.000 18.952 469 4.252 2 08:26 14.9 41.7 75.3 69.3 63.97 97091 0.000 0.000 19.243 .476 4.318 3 08:41 14.9 42.2 75.3 69.3 63.97 0.000 0.000 19.077 472 4.281 4 08:56 14.9 42.7 75.3 69.2 63.97 97085 97083 0.000 0.000 19.266 476 4.324 5 09:11 14.9 42.5 75.3 69.0 63.96 97 m -25.016 .618 18.768 464 4.213 6 09:26 14.9 42.7 75.3 69.3 63.96 97064 -27.003 .669 18.611 .460 4.178 7 09:41 14.9 43.2 75.3 69.3 63.95 63.95 97059 -26.780 .662 19.223 475 4.315 8 09:56 14.9 43.2 75.3 69.3
[
N]./~
9 10:11 14.9 43.3 75.3 69.3 63.94 97054 -26.217 .648 19.145 473 4.298 69.3 63.74 97050 -25.394 .628 18.316 453 4.112 10 10:26 14.9 43.5 75.3 63.94 97041 -25.529 .631 19.669 496 4.416 11 10:41 14.9 44.2 75.3 69.3 63.93 97037 -25.070 .620 19.290 .477 4.331 12 10:56 14.9 44.4 75.3 69.3 63.93 97032 -24.723 .611 19.439 482 4.376 13 11:11 14.9 45.0 75.3 69.3 75.2 69.2 63.92 97027 -24.311 .601 18.600 460 4.177 14 11:26 14.9 45.1
' 19.444 481 4.366 15 11:41 14.9 45.5 75.3 69.3 63.92 97020 -24.186 .598 97017 -23.810 .588 18.705 462 4.201 16 11:56 14.9 46.1 75.3 69.3 63.92 O.
4 f Appendix F Sheet 2 i
t 1 Jan 1986 HOPE CREEK GENERATING STATION RECALC-VERIFICATION TEST l ArEIENT CONTAINrENT j i SCW Tiff PRESS TEf1P TEMP DEU PT PRESS f1 ASS LEAK RATE SUPERif1 POSED No. Hour Psia DegF DegF DegF Psia Lbn Lbs/Hr 4/ Day LbvHr %/ Day Scfm
]
! 17 12:11 14.9 45.3 75.2 69.3 63.92 97016 -23.083 .571 18.693 .462 4.198 l
I l
4
't I
i l
l i
4 i
4 l
t 4
i i
e i
i t
- - - - - - - - - . , - _ - .._ -._,,,--_- -,_ ,- . _ _ _ , _ _ . . . , _ _ . . . ~ , , . . . . . . _ _ . . . . _ . . - . . - . . . _ . . . . .
Appendix G Sheet 1 Bypass Differential Pressure Data
(~h O' 3 Jan 1986 HOPE CREEK GEERATING STATION BYPASS TEST DATA DRY WELL TORUS PRESS PRESS DIFF DIFF DIFF SCAN TIME Psia Psia Psi Psi / min In/ min No. Hour 14.705 1.129 0.0000 0.0000 1 00:51:33 15.834 14.705 1.129 0.0000 0.0000 2 00:51:47 15.834 e
14.705 1.129 0.0000 0.0000 3 00:52:02 15.834 14.705 1.129 0.0000 0.0006 .
4 00:52:17 15.634 t
15.834 14.705 1.129 0.0000 0.0000 5 00:52:32 14.705 1.129 0.0000 0.0000 6 00:52:47 15.834 15.834 14.705 1.129 0.0000 0.0000 7 00:53:02 00:53:17 15.834 14.705 1.129 0.0000 0.0000 8
9 00:53:32 15.834 14.705 1.129 0.0000 0.0000 ,
00:53:47 15.834 14.705 1.129 0.0000 0.0000 10 90:54:02 15.834 14.705 1.129 0.0000 0.0000 11 12 00:54:17 15.834 14.705 1.129 0.0000 0.0000 13 00:54:32 15.834 14.705 1.129 0.0000 0.0000 14 00:54:47 15.834 14.705 1.129 0.0000 0.0000 i
i 15 00:55:02 15.834 14.704 1.130 .0010 . .0277 16 00:55:17 15.830 14.703 - - . s.l .127 .0020 .0553 i
17 00:55:32 15.830 14.703 1.127 .0020 .0553 l
18 00:55:47 15.830 14.703 1.127 .0020 .0553 ,
00:56:02 15.830 14.703 1.127 .0030 .0830 19 15.830 14.703 1.127 0.0000 0.0000 20 00:56:17 1
U .
1 E
. . . - , . , , . . . , _ . - _ - . ,,,v. . , -, ,, - - , . . . . . . , - . - c,.,.-~,- - . . ~ , , - r -,, .. ,,,,,,--,# -
-c e. 'w-- ,.--y a.r-+,r-,y--,-<
Appendix G Sheet 2 Bypass Differential Pressure Data o 1
3 Jan 1986 HOPE CREEK GEERATING STATION
' BYPASS TEST DATA 0:Y UELL TORUS PRESS PRESS DIFF OlFF O!FF SCAN TIME hr Psia Psia Psi Psi / min In/ min No.
15.830 14.704 1.126 .0010 .0277 21 00:56:32 14.704 1.126 .0010 .0277 22 00:56:47 15.830 00:57:02 15.830 14.705 1.125 .0020 .0554 23 00:57:17 15.830 14.705 1.125 .0020 .0554 24 I 25 00:57:32 15.830 14.705 1.125 .0010 .0277 26 00:57:47 15.930 14.705 1.125 .0010 .0277
! 27 00:59:02 15.830 14 704 1.126 .0010 .0277 29 00:58:17 15.830 3.703 1.127 .0020 .0554 O
'(,) 29 00:53:32 15.830 14.703 1.127 .0020 .0534 30 00:59:47 15.830 14.703 1.127 .0020 .0554 31 00:59:02 15.830 14.703 1.127 .0010 .0277
! 32 00:59:17 15.83J 14.703 1.127 0.0000 0.0000 33 00:59:32 15.830 14.703 1.127 0.0000 0.0000 34 00:59:47 15.830 14.703 1.127 0.0000 0.0000 35 01:00:02 15.830 14.703 1.127 0.0000 0.0000 36 01:00:17 15.830 1,'. /0) 1.127 0.0000 0.0000
{.
37 01:00:32 15.830 14.703 1.127 0.0000 0.0000 i 38 01:00:47 15,830 14.703 1.127 0.0000 0.0000 39 01:01:02 15.830 14.703 1.127 0.0000 0.0000 1
i 40 01:01:17 15.830 14./03 1.127 0.0000 0.0000 t
J h (
Sheet 3 s
i Bypass Differential Pressure Data O
4 3 Jan 1986 HOPE CREEK GEERATING STATION BYPASS TEST DATA 1
, CRY i.: ELL TORUS I SCAN T!T PRESS PRESS DIFF DIFF OlFF No. Hour Psia Psta Psi Ps / min In/ min
! 41 01:01:32 15.830 14.703 1.127 0.0000 0.0000 42 01:01:47 15.830 14.703 1.127 0.0000 0.0000 43 01:02:02 15.830 14.703 1.127 0.0000 0.0000 44 01:02:17 15.830 14.703 1.127 0.0000 0.0000 l 45 01:02:32 15.830 14.703 1.127 0.0000 0.0000 1
46 01:02:47 15.830 14.703 1.127 0.0000 0.0000 47 01:03:02 15.829 14.703 1.126 .0010 .0277 48 01:03:17 15.829 14.703 1.126 .0010 .0277 i
O
\/
49 01:03:32 15.829 14.703 1.126 .0010 .0277 50 01:03:47 15.829 14.703 1.126 .0010 .0277 .
51 01:04:02 15.829 14.703 1.126 0.0000 0.0000 52 01:04:17 15.829 14.703 1.126 0.0000 0.0000
- 53 01
- 04:32 15.829 14.703 1.126 0.0000 0.0000 54 01:04:47 15.829 14.703 1.126 0.0000 0.0000 55 01:05:02 15.829 14.702 1.127 .0010 . . 0277 56 01:05:17 15.829 14.701 1.128 .0020 . 0554 l l
57 01:05:32 15.829 14.701 1.128 .0020 . 0!54 I 58 01:05:47 15.828 14.701 1.127 .0010 . 0277 59 01:06:02 15.828 14.701 1.127 0.0000 0.0000 60 01:06:17 15.828 14.701 27 .0010 .0277 O l
,w- r - v.,- ..-.w ,-.-r+ . . . , -n-- , ,, -r- -.,.-----v.-,, , ,,.n . . -
Appendix G Sheet 4 Bypass Differential Pressure Data
! (nV, 3 Jan 1986 .
l HDPE CREEK GENERATING STATION SYPASS TEST DATA DRY WEl.1. TORUS PRESS DIFF DIFF DIFF SCAN TIME FRESS Psia Psia Psi Psi / min In/ min No. Hour 14.701 1.127 .0010 .0277 i 61 01:06:32 15.828 14.701 1.127 0.0000 0.0000 I 62 01:06:47 15.828 14.701 1.127 0.0000 0.0000
' 63 01:07:02 15.828 14.701 1.127 0.0000 0.0000 64 01:07:17 15.828 14.701 1.127 0.0000 0.0000 65 01:07:32 15.828 14.701 1.127 0.0000 0.0000 66 01:07:47 15.S28 01:C8:02 15.828 14.701 1.127 0.0000 0.0000 l 67 68 01:08:17 15.828 14.701 1.127 0.0000 0.0000
, p I 69 01:C8:32 15.828 14.701 1.127 0.0000 0.0000 1.127 0.0000 0.0000 ,
l 70 01:08:47 15.823 14.701 71 01:09:02 15.827 14.698 1.129 .0020 .0554 L
01:09:17 15.026 14.698 1.128 .0010 .0277 72 5
73 01:09:32 15.826 14.698 1.128 .0010 .0277 74 01:09:47 15.826 14.699 1.127 0.0000 0.0000 75 01:10:02 15.826 14.699 1.127 0020 . .0554 76 01:10:17 15.826 14.699 1.127 .0010 .0277 01:10:32 15.826 14.699 1.127 .0010 0277 77 l
01:10:47 15.826 14.699 1.127 0.0000 0.0000 78 01:11:02 15.826 14.699 1.127 0.C000 0.0000 79 14.699 1.127 0.0000 0.0000 I
80 01:11:17 15.826 O
- - - . , , - - , , . ~ , . . , _ _ . - . . , _.- ..--,e - .m.,--...-,,,--. .-s.- ---..*e.--m .*,--,..-c y w
1
- Appendix G 1
i Sheet 5 1
i Bypass Differential Pressure Data jt s 3 Jan 1986 HOPE CREEK GEERATING STATION BYPASS TEST DATA DRY I.EL1, TORUS
! TIME PRESS PRESS DIFF DIFF DIFF SCAN No. Hour Psia Psia Psi Psi / min In/ min 81 01:11:32 15.826 14.699 1.127 0.0000 0.0000 4
14.699 1.127 0.0000 0.0000 82 01:11:47 15.026 i 83 01:12:02 15.826 14.699 1.127 0.0000 0.0000 1
01:12:17 15.026 14.699 1.127 0.0000 0.0000
! 64 85 01:12:32 15.826 14.699 1.127 0.0000 0.0000 86 01:12:47 19.826 14.698 1.128 .0010 .0277 f
87 01:13:02 15.826 14.699 1.127 0.0000 0.0000 i
t 88 01:13:17 15.826 14.699 1.127 0.0000 0.0000 i
]
i e
1 4
I l
i l
1 i
l' 1
I e L
i -
i
- . , - , - - . - . _ _ _ _ _ . _.,,--_-._,,-.-,,.-..,._.-..,,.--,.-.._,...,_m----,m.m.,__,,--,,,__,,_._m.,....,_m.. . , , - . . . . . . , , . . - _ . .
- 8%$/N([# M ** ' -- -
Appendix H M oRuwflL
.,- I i.,,
tow l J. w *
,,*,O
/ \ ' Sheet 1 JEL.139 7,, % \' *
?
?
N
~
LOCATION . ! oar,.A,.mo LOCATION.
I
- / x:e ,.}.
(% DEW POINT s j
"r" ?? '-
J W A:W7'C d SENSORS 0 @ '
%u ,
-- l RTD SENSORS
"-r -
( 0 ea..nr:s
- _ _ _ _ _ _ .py .-any m-'- . ~
,)
. ._43
-- ]
nac.=n c.s:L.
~j J
- -!HL"'.',
erorsacecv. eEto 1 El* 162'
- 22 '$#f,Cr"jf 32 El. 162' at Az 45*' ' l ., ..-w( 45
.e':.fiy _ _ pl - _f , 165 ,
[f! me air;. coh' i_Lo_a 2g5o I e . l
,el l l* -wn.c "a
, I
- e; *. \-
s I
_ . ...e,c. ' .t, */. C.
'. g , . ,
stoto: stat. sweto -
-& ' (. , . ca,-
_ l _
l Ah_. n ', li w.f..hl cer iai
~q l; / - .\
H :- -
Qr
^
- i Z. ,
g
..N I* I s . l f. (
El. 112' rRovat eurm,w ; F;v' El. 122' f 1: I-
_ .. - .a , Az 45*, 135*, 225*,
Az 45*, 165 ,
/.r.clYef..Iri@i l .
+ a v g. us a M,t ~}' , 8...
e ~
315*
285* l' . - ...- .. '
- i,, ,. ves.,ijt .w s .:'.
i '.'-u W l ,
[xWM
,O y._. _ _._ _
l not ot*4.Gn;e
!= ~. .
L_g re g a_ pe.g5* .
E:vmonw
' , e s m :rg.-12),t fric t
e :e vusn L' Y. ,-i i roem p w'-:*/N c
,.i' l Q'f- ' ! 3 rt M.g
/ _!' ', E1. 100'
@'[,# T. 1- h.,1I.,r,v cf;3d?! ,u e v w / l l -
Az 45 , 135*, 225*,
- W.
r -"%.-, - - * ~
=
l r
e,.ff y . .f,,7 i./y 315o
- i s>=pensu
$s . . g, -,,a g . . - -
o wtstappes, .
.<~<r :lg < #m 5.11=wn f.s ,. % M '. j d'..-J 3 $3;,y g$3..g*V.-Q d h_._v.- @
.{g"*l fg*XT;p
} 3 .f.(
I r A#E l [ Y^ r ?,.r ..
M.*,- w 4 t.p *p.c rwa Ar l
- D4vs':.g?!;:.:O=.5 ""gm W
~~
I / ~
c3. 1 T
-Q \
l1 1m W, ! - u x.. rea r ett r** bet.72;4- . l wrh.gear ='-- ik $. d.$
. cr . I
. w.--- - e - r.o.c. rt ai'- s'@ ,- y ra ar- - f
- 1' m.,g; j j - { ". ~ **El. ( i g ,. .. p' CYuamr. i,._irl.!
76'-6") 3 b lAz 45*, 225 ,, y - . ,l ,. / IP *'El. 76'-6" 'I
'l
, 1/
!t,.
.e l
i 6Az 45*, 105*,225 i 285*,345*.d
& lll xi d.#:"
h.
r .-.',; }
q s .o r e w W
9**,
l
. n- AQe*r
- p TO C. EL. C4:Q *It*Co * *>A L)
,.f-e . . _ _
)
pp W-4 E0 \ *%
Csesso,,ge*Na r: otsinaoorg s ' Mitst W Les J
.r '" oe eco c.r.rr.
\ .$C,t4* CAQst/5 ~
.1 . or prosM) b___
1 Appendix I 1 Sheet 1 O HOPE CREEK GEERATING STATION 2 Jan 1986 1
EIGH FACT (R File 6 3
, TDFERATURE WEIGH FACTOR 1
RTD 10. LADEL EIGH FACTOR 1 EL 162 Az 45 4.71 2 El 162 Az 165 4.71 i 3 El 162 Az 285 4.71 4 El 122 k 45 4.51
, 5 El 122 Az 135 4.51 6 El 122 Az 225 4.51 7 El 122 Az 315 4.51
+
8 El 100 Az 45 5.63 9 El 100 Ar 135 5.63 10 El 100 Az 225 5.63 11 El 100 Az 315 5.63 12 Torus Az 45 7.55 13 Torus 105 7.55 14 Torus 165 7.55 15 Torus 225 ,. 7.55 Torus 285 7.55 O
16
- 17 Torus 345 7.55
- Weigh Factor total is 100.0 if total is not 1004 then correct 300 D.P. TDFERATURE ElGH FACTOR D.P. 10. LAGEL ElGH FACTOR 1 El 162 Az 45 14.12 2 El 100 Az 45 0.00 3 El 100 Az 165 0.00 4 El 100 Az 285 40.59 5 Torus Ar 45 .22.65 +
6 Torus Az 225 22.65 D.P. weigh factor total is 100.0 if total is not 100% then correct -
PRESSLRE EIGH FAC10R T I HO. LAGEL WElGH FACTOR 1 U606 50.00 2 V007 50.00 O
9 e
Appundix J ,
LOCAL LEAKACE TEST DATA Tcble 1 J TYPE B PNEUMATIC TEST RESULTS Sheet 1 of 12 ;
i DESCRIPTION LEAKAGE (SCCM)
PENETRATION NO.
MAIN STEAM A PENETRATION 2.2 l PlA DOUBLE BELLOWS MAIN STEAM B PENETRATION O PIB DOUBLE BELLOWS MAIN STEAM C PENETRATION O Plc DOUBLE BELLOWS MAIN STEAM D pef.ETRATION 1 0 PID DOUBLE BELLOWS FEEDWATER B PENE'TRATION 1.2 P2A DOUBLE BELLOWS (D
q / P2B FEEDWATER A PENETRATION 4.5 DOUBLE BELLOWS RHR SHUTDOWN COOLING 0 P3 PENETRATION DOUBLE BELLOWS RHR SHUTDOWN COOLING 5.3 P4 A PENETRATION DOUBLE BELLOWS (NOTE 1)
RHR SHUTDOWN COOLING 4 P4B PENETRATION DOUBLE BELLOWS CORE SPRAY PENETRATION 4.9 PSA DOUBLE BELLOWS (NOTE 2)
O v
n m-
i Appendix J LOCAL LEAKAGE TEST DATA Table 1 TYPE B PNEUMATIC TEST RESULTS Sheet 2 of 12 O l (m,1 DESCRIPTION LEAKAGE (SCCM) ;
PENETRATION NO.
l EORE SPRAY PENETRATION 6 PSB DOUBLE BELLOWS RHR, LPCI PENETRATION DOUBLE (NOTE 2)
P6A BELLOWS RHR, LPCI PENETRATION DOUBLE (NOTE 1)
P6B d BELLOWS RHR, LPCI PENETRATION 2 P6C DOUBLE HELLOWS
.P6D DOUBLE BELLOWS
)
HPCI - TURBINE STEAM 13 P7
- PENETRATION DOUBLE BELLOWS P8A CHILLED WATER PENETRATION (NOTE 1)
DOUBLE BELLOWS P8B CHILLED WATER PENETRATION (NOTE 2)
DOUBLE BELLOWS RWCU PUMP SUCTION 0.1 P9 PENETRATION DOUBLE BELLOWS P10 RHR RX. HEAD SPRAY 11.4 ?
PENETRATION DOUBLE BELLOWS ,
s
LOCAL LEAKAGE TEST DATA Appendix J TYPE D PNEUMATIC TEST RESULTS Table 1 Sheet 3 of 12 PENETRATION NO. DESCRIPTION LEAKAGE (SCCM) i i
Pil RCIC TURBINE STEAM (NOTE 2) j PENETRATION DOUBLE BELLOWS P12 MAIN STEAM DRAIN PENETRATION 4.2 DOUBLE BELLOWS P34A TIP PROBE TUBE FL\NGE O l P34B TIP PROBE TUBE T'LANGE O P34C TIP PROBE TUBE FLANGE O P34D TIP PROBE TUBE FLANGE 0 P34E TIP PROBE TUBE FLANGE O
. O P34F TIP PURGE PENETRATION FLANGE O P34G TIP PROBE SPARE PENETRATION 0 FLANGE P38A CHILLED WATER PENETRATION O
, DOUBLE BELLOWS P38B CHILLED WATER PENETRATION 2.0 DOUBLE BELLOWS l
C-1 DRYWELL EOUIPMENT HATCH SEAL 2.34 C-2 DRYWELL EOUIPMENT HATCH SEAL 0.85 0
--, , .-. . , . ,-,,,c--
, ,n ,, ,, , -., v-~. ,
Appendix J LOCAL LEAKAGE TEST DATA Tablo 1 TYPE B PNEUMATIC TEST RESULTS Sheet 4 of 12 O LEAKAGE (SCCM)
PENETRATION NO. DESCRIPTION DRYWELL PERSCNNEL AIR LOCK, (NOTE 3)
C-2 ATMOSPHERE BULKHEAD DOOR SEAL DRYWELL PERSONNEL AIR LOCK, (NOTE 3)
C-2 CONTAINMENT HULKHEAD DOOR SEAL DRYWELL PERSONNEL AIR LOCK, (NOTE 3)
C-2 ATMOSPHERE BULKHEAD FOOT PEDAL DRYWELL PERSONNEL AIR LOCK, (NOTE 3)
C-2 ATMOSPHERE REMOTE DOOR INDICATOR C-2 DRYWELL PERSONNEL AIR LOCK, (NOTE 3)
ATMOSPHERE BULKHEAD HANDWFiEEL SHAPT C-2 DRYWELL PERSONNEL AIR LOCK, (NOTE 3 )
CONTAINMENT BULKHEAD INTERLOCK SHATT C-2 DRYWELL PERSONNEL AIR LOCK, (NOTE 3)
CONTAINMENT BULKHEAD HANDWHEEL SHAPT C-2 DRYWELL PERSONNEL AIR LOCK, 1440 CHAMBER. (NOTE 3)
CONTROL ROD DRIVE REMOVAL 0 C-3 HATCH COVER SEAL ,
C-5 DRYWELL HEAD INSPECTION }0 HATCH SEAL ,
, \
1 1
l
1 LOCAL LEAKAGE TEST DATA Appandix J Table 1 TYPE D PNEUMATIC TEST RESULTS Sheet 5 of 12 DESCRIPTION LEAKAGE (SCCM)
PFNETRATION NO.
- DRYWELL HEAD SEAL 5.7
- DRYWELL SHEAR LUG INSPECTION O COVER SEAL 0*
- DRYWELL SHEAR LUG INSPECTION O COVER SEAL 4 5'
- DRYWELL SHEAR LUG INSPECTION 0 COVER SEAL 90
- DRYWELL SHEAR LUG INSPECTION O COVER SEAL 135'
- DRYWELL SHEAR LUG INSPECTION O
() COVER SEAL 180'
- DRYWELL SHEAR LUG INSPECTION O COVER SEAL 225
- DRYWELL SHEAR LUG INSPECT 1od 0 COVER SEAL 270*
- DRYWELL SHEAR LUG INSPECTION O COVER SEAL 315*
TORUS ACCESS HATCH SEAL 0 C201A TORUS ACCESS HATCH SEAL 0 C201B 0
4
IACAL LEAKAGE TEST DATA Appendix J TYPE B PNEUMATIC TEST RESULTS Table 1 Sheet 6 of 12
,m PENETRATION NO. DESCRIPTION LEAKAGE (SCCM)
C201C TORUS ACCESS HATCH SEAL 0.57 C201D TORUS ACCESS HATCH SEAL 2.2 P221A TORUS DRAIN COVER SEAL 0 P221B TORUS DRAIN COVER SEAL 0 P221C TORUS DRAIN COVER SEAL 0 P221D TORUS DRAIN COVER SEAL 0 P229A DRYWELL VENT LINE DOtIBLE O BELLOWS
,s ~)
, P229B DRYWELL VENT LINE DOllRLE O BELLOWS P229C DRYWELL VENT LINE DOUBLE 5.7 BELLONS P229D DRYWELL VENT LINE DOUBLE O BELLOWS P229E DRYWELL VENT LINE DOUBLE O BELLOWS P229F DRYWELL VENT LINE DOUBLE O BELLOWS
r~ l LOCAL LEAKAGE TEST DATA Appendix J TYPE D PNEUMATIC TEST CESULTS Table 1 Sheet 7 of 12
-s DFSCRIPTION LEAKAGE (SCCM)
PENETRATION NO.
DRYWELL VENT LINE DOUBLE D P229G BELLOWS DRYWELL VENT LINE DOUBLE O P229H BELLOWS 1-GS-V009 - CONTAINMENT O P22 SIDE FLANGE 1-GS-V024 - CONTAINMENT 0.16 P23 SIDE FLANGE l-GS-V028 - CONTAINMENT 0.7 P219 SIDE FLANGE ( NOTE 4 )
/
( ,) P219 l-GS-VO80 - CONTAINMENT ( NOTE 4 )
SIDE FLANGE .
1-GS-V022 - CONTAINMENT (NOTE 5)
P220 SIDE FLANGE 0.7 1-GS-V038 - CONTAINMENT (NOTE 5)
P220 SIDE FLANGE ELECTRICAL PENETRATION 0 W100A 1AW200 ELECTRICAL PENETRATION O W1008 IBW200 0
j
- . ~ . . . ..- .. . -. . - . .- . . .- -
1-LOCAL LEAKAGE TEST DATA ' Appendix J TYPE B PNEUMATIC TEST RESULTS Table 1 Sheet 8 of 12
~O i
1 PENETRATION NO. DESCRIPTION LEAKAGE _(SCCN1
,; W100C ELECTRICAL PENETRATION O
! ICW200 W1000 ELECTRICAL PENETRATION O 1DW200 W101A ELECTRICAL PENETRATION O j IAW201 W10lR ELECTRICAL PENETRATION 0 l IBh201 1
W101C ELECTRICAL PENETPATION O
- ICW201 I
i W101D ELECTRICAL PENETRATION 0 i 1DW201
)
l W101E ELECTRICAL PENETRATIOV O lEW201 1
W101F ELECTPICAL PENETRATION O 1FW201 WIO2A ELECTRICAL PENETRATION O 1AW202 W102B ELECTRICAL PENETRAT. ION O IBW202 O
IDCAL LEAKAGE TEST DATA Appendix J TYPE B PNEUMATIC TEST RESULTS Table 1 Sheet 9 of 12 O PENETRATION NO. DESCRIPTION LEAKAGE (SCCM)
W102C ELECTRICAL PENETRATION 0 1CW202 W102D ELECTRICAL PENETRATION 0 1DW202 W103A ELECTRICAL PENETRATION 0 1AW203 W103B ELECTRICAL PENETRATION 0 1BW203 W104A ELECTRICAL PENETRATION O 1AW204 W104B ELECTRICAL PENETRATION 0 1BW204 W104C ELECTRICAL PENETRATION 0 1CW204 W104D ELECTRICAL PENETRATION 0 1DW204 l W104E ELECTRICAL PENETRATION 0 1EW204 W104F ELECTRICAL PENETRATION 0 1FW204 O
l
i LOCAL LEAKAGE TEST DATA Appendix J f Table ] l TYPE B PNEUMATIC TEST RESULTS Sheet 10 of 12 O PENETRATION NO. DESCRIPTION LEAKAGE (SCCM) l W104G ELECTRICAL PENETRATION 0 l
\
1GW204 W104H ELECTRICAL PENETRATION O lHW204 l l
ELECTRICAL PENETRATION 0 W104J l lJW204 l l
W104K ELECTRICAL PENETRATION 0 1KW204 W105A ELECTRICAL PENETRATION O 1AW205 O
' WJ105R ELECTRICAL PENETRATION 0 1BW205 W105C ELECTRICAL PENETRATION O 1CW205 W105D ELECTRICAL PENETRATION O 1DW205 W105E ELECTRICAL PENETRATION 0 1EW205 l
W105F ELECTRICAL PENETRATION 0 1FW205 O
LOCAL LEAKAGE TEST DATA Appendix J TYPE B PNEUMATIC TEST RESULTS Table 1 Sheet 11 of 12
' .;NPTR A TION NO. DESCRIPTION LEAKAGE (SCCM)
W105G ELECTRICAL PENETRATION 0 1GW205 W105H ELECTRICAL PENETRATION O 1HW205 W106A ELECTRICAL PENETRATION 0 1AW206 W106B ELECTRICAL PENETRATION 0 1BW206 W106C ELECTRICAL PENETRATION 0 1CW206 blA ELECTRICAL PENETRATION 0 1AW207 ,
c W20lH , ELECTRICAL PENETRATION O 1BW207 W201C ELECTRICAL PENETRATION O ICW207 l W201D ELECTRICAL PENETRATION O 1DW207 i
! W202A ELECTRICAL PENETRATION 0 1AW208 i'
1
..-.,----_.,..-..r,- . - - _ , - _ _ , _ . . , . ._ _.._ .---~_...___-..en.,_.,,._, - - - , , . , . , , - , . .
LOCAL LEAKAGE TEST DATA Appendix J l TYPE B PNEUMATIC TEST RESULTS Table 1 Sheet 12 of 12 O PENETRATION NO. DESCRIPTION LEAKAGE (SCCM)
W203A ELECTRICAL PENETRATION O 1AW209 TYPE 'B' LLRT - TOTAL +
1,524.72(SCCM)
NOTE 1: PENETRATION BELLOWS WERE TESTED IN PARALLEL WITH RESULTS LISTED AT P4A.
NOTE 2: PENETRATION BELLOWS WERE TESTED IN PARALLEL WITH RESULTS LISTED AT P5A.
NOTE 3: PERSONNEL AIRLOCK PENETRATIONS AND DOOR SEAL WERE TESTED BY THE OVERALL PERSONNEL AIRLOCK TEST.
t i r4slE 4: VALVE FLANGES FOR 1-GS-V028 AND l-GS-V080 WERE TESTED IN PARALLEL.
NOTE 5: VALVE FLANGES FOR l-GS-V022 AND l-GS-V038 WERE TESTED IN PARALLEL. ;
. i l
l l
l l
l l
I Appendix J LOCAL LEAKAGE TEST DATA Table 2 TYPE C PNEUMATIC TEST RESULTS l Sheet 1 of 7 I
DESCRIPTION LEAKAGE (SCCM)
FEEDWATER LINE 257 (NOTE 1)
P2A FEEDWATER LINE 96H P2B RESIDUAL HEAT REMOVAL - 950 P3 SHUTDOWN COOLING SUCTION RESIDUAL HEAT REMOVAL - 18 P4A SHUTDOWN COOLING RETURN RESIDUAL HEAT REMOVAL - 165 P4B SHUTDOWN COOLING RETURN CORE SPRAY TO REACTOR 922 PSA CORE SPRAY TO REACTOR 902.4 O[^7 LOW PRESSURE COOLANT 1267 P6A INJECTION - RHR LOW PRESSURE COOLANT 253 P6B INJECTION - RHR (NOTE 1)
LOW PRESSURE COOLANT 304.8 P6C INJECTION - RHR ,
LOW PRESSURE COOLANT 315 P6D INJECTION - RHR I
l O
l Appendix J LDCAL LEAKAGE TEST DATA Table 2 TYPE C PNEUMATIC TEST RESULTS Sheet 2 of 7 1
\
DESCRIPTION LEAKAGE (SCCM)
HIGH PRESSURE COOLANT 192.1 P7 INJECTION TURBINE STEAM SUPPLY CHILLED WATER FROM DRYWELL 580 P8A COOLERS CHILLED WATER TO DRYWELL 650 P8B COOLERS REACTOR WATER CLEANUP 0.2 P9 SUPPLY RESIDUAL HEAT REMOVAL - 27.0 P10 HEAD SPRAY REACTOR CORE ISOLATION 8.59
\. -_s COOLING TURBINE STEAM SUPPLY MAIN STEAM DRAIN 96 P12 REACTOR RECIRCULATION WATER 7.5 P17 SAMPLE STANDBY LIOUID CONTROL 21 PIB REACTOR RECIRCULATION PUMP 0 P19 SEAL WATER l
0
J Appendix J LOCAL LEAKAGE TEST DATA Table 2 TYPE C PNEUMATIC TEST RESULTS Sheet 3 of 7 DESCRIPTION LEAKAGE (SCCM) 4.6 P20 REACTOR RECIRCULATION PUMP SEAL WATER DRYWELL PURGE INLET VENT 1083.5 P22 2190 P23 DRYWELL PURGE OUTLET VENT RESIDUAL HEAT REMOVAL - 1663.9 P24A CONTAINMENT SPRAY 880 P248 RESIDUAL HEAT REMOVAL -
CONTAINMENT SPRAY 96.7 P25 DRYWELL FLOOR DRAIN SUMP DISCHARGE 82 O) kum DRYWELL EOUIPMENT DRAIN SUMP DISCHARGE SERVICE AIR TO DRYWELL 240 P27 24 P28A INSTRUMENT GAS TO DRYWELL 72 P28B INSTRUMENT GAS TO DRYWELL REACTOR AUXILLIARY COOLING 174.7 P29 RETURN REACTOR AUXILLIARY COOLING 93.55 P30 RETURN
- l
LOCAL LEAKAGE TEST DATA Appsndix J TYPE C PNEUMATIC TEST RESULTS Table 2 Sheet 4 of 7 DESCRIPTION LEAKAGE (SCCM)
BREATHING AIR 69.6 P31 PROBE GUIDE TUBE 1.5 P34A PROBE GUIDE TUBE 20.5 P34B PROBE GUIDE TUBE 1.1 P34C PROHE GUIDE TUBE 8.2 P34D PROBE GUIDE TUBE 48 P34E TRAVERSING INCORE PROBE O P34F PURGE 8A CHILLED WATER TO DRYWELL 462 COOLERS CHILLED WATER PROM DRYWELL 792 P38B COOLERS P39 INSTRUMENT GAS SUCTION 119 P204 HPCI & RCIC VACUUM NETWORK 71.2 P214A RESIDUAL HEAT REMOVAL TO 296 TORUS SPRAY HEADER P214B RESIDUAL HEAT REMOVAL TO 322 TORUS SPRAY HEADER G
v
l LOCAL LEAKAGE TEST DATA Appundix J Table 2 j TYPE C PNEUMATIC TEST RESULTS Shsst 5 of 7 ]
DESCRIPTION LEAKAGE (SCCM)
ETRATION NO.
ll TORUS PURGE OUTLET AND 432.45 P219 TORUS VACUUM RELIEF 1 TORUS PURGE INLET AND TORUS 752 P220 VACUUM RELIEF (NOTE 2) l 0.4 P227 POST ACCIDENT LIOUID SAMPLING RETURN 0.4 J3B HYDROGEN / OXYGEN ANALYZER INLET REACTOR COOLANT PRESSURE 66.6 J5A hqUNDARY LEAKAGE DETECTION GAS SAMPLER RETURN HYDROGEN / OXYGEN ANALYZER 70
)D INLET POST ACCIDENT GAS SAMPLE 1.2 J7E REACTOR COOLANT PRESSURE 14.8 J8C BOUNDARY LEAKAGE LEAKAGE DETECTION GAS SAMPLER SUPPLY HYDROGEN / OXYGEN ANALYZER 5.31 J9E INLET l
l HYDROGEN / OXYGEN ANALYZER 35 J10C INLET O
V
i LOCAL LEAKAGE TEST DATA Appendix J TYPE C PNEUMATIC TEST RESULTS Table 2 i Shnet 6 of 7 )
i PENETRATION NO. DESCRIPTION LEAKAGE (SCCM) viOE POST ACCIDENT GAS SAMPLE 1.4 4
J36C ILRT LINE 3.84 J36D ILRT LINE 6.92 <
l 1
J50 JET PUMP FLOW / POST 2.0
- ACCIDENT SAMPLING 2
t J201 TORUS OUTLET TO "A" 83.5 l
l HYDROGEN / OXYGEN ANAL'ZER f J202 TORUS OUTLET TO "B" 50 l HYDROGEN / OXYGEN ANALYZER l
j J206 POST ACCIDENT SAMPLING 62.7 i
O k/JgD9 TORUS WATER LEVEL /ILRT LINE 6.79 l
J210 TORUS INLET TO "B" HYDROGEN 3.1 i / OXYGEN ANALY2ER
! J211 INSTRUMENT AIR TO TORUS 13.5
] J212 TORUS INLET TO "A" HYDROGEN / 60.6 ,
OXYGEN ANALYZER 1
i I
l
. O i
IACAL LEAKAGE TEST DATA Appendix J TYPE C PNEUMATIC TEST RESULTS Table 2 Sheet 7 ot 7 PENETRATION NO. DESCRIPTION LEAKAGE (SCCM)
\v/20 POST ACCIDENT SAMPLING 62.8 ,
i J221 POST ACCIDENT GAS SAMPLING 34.5 i
l PNEUMATIC TYPE "C" LLRT TOTAL 18,490.45(SCCM) i i
NOTE 1: Failed LLRT prior to ILRT - Results are post ILRT.
i NOTE 2: Valves 1-GS-V020 and 1-GS-V022 were tested in I
parallel with valves 1-GS-V009, 1-GS-V021 and 1-GS-V023. Results are listed with P-22.
.i i O
)
1 i
l l )
i
!O 1
, _ _ _ - . . . _ . . . _ _ , _ . . _ _ - . _ _ . - . _ - _ _ , , _ . . - . _ . ~ , . _ . . . _ , _ _ , ,, .-.__,...,__.__._____...____.._,_,,-,..-,_,.,__.__,_..m._..._
LOCAL LEAKAGE TEST DATA Appsndix J
, NYDRDSTATIC LOCAL LEAKAGE TEST RZULTS Tcble 3 Shret 1 of 2 l PENETRATION NO. DESCRIPTION LEAKAGE (GPM)
Ov201 High Pressure Coolant 0.018 Injection Turbine Exhaust j
P202 High Pressure Coolant 0.002 i Injection Pump Suction
. P203 High Pressure Coolant 0.049 Injection Minimum Return
- P207 Reactor Core Isolation 0.041
- Cooling Turbine Exhaust i
! P208 Reactor Core Isolation 0.082 1
Cooling Pump suction P209 Reactor Core Isolation 0.720 Cooling Minimum Return
)
j P210 Non-condensable gas from 0.004 RCIC vacuum pump P211A Residual Heat Removal 0.036 pump suction P2118 Residual Heat Removal 0,001 pump suction P211C Residual Heat Removal 0.001 pump suction i
o
..__-._._.,,.,-__.-....__,..-..,_.._,__m,,,._,_- ~~_,my- -__ , _ _ . _ . _ . ,._.,_._.-._,m. . . _ _ _ _ , . , . . _ _ - . _ _ _ _ _ . _ - , . _ , . - _
1 1
Appendix K Sheet 1 l l
()
ILRT DATA ACQUISITION SYSTEM i
RTD l Bridge Completion 100 ohms @ 32F Precision Digital Multimeter
) l DC Power Supply Dew Point 100'F = 2.5 VDC Comptroller Hydrometer Computer Interface Multiplexer "-
IEEE 488 Thermal Mass 10 CFM = 10 VDC Plow Meter 10 CFM Quarts Manometer Binary 100 Psia l
1821H/8
_ 1