__

Public Service Electric and Gas Company Corbin A. McNeill, Jr.

Public Service Electnc and Gas Company P.O. Box 236, Hancocks Bridge, NJ 08038 609 339-4800 Vice President -

Nuclear April 7, 1986 Director of Nuclear Reactor Regulation United States Nuclear Regulatory Commission 7920 Norfolk Avenue Bethesda, Maryland 20814 Attention:

Ms. Elinor Adensam, Director Project Directorate 3 Division of BWR Licensing

Dear Ms. Adensam:

PRIMARY REACTOR CONTAINMENT PREOPERATIONAL INTEGRATED LEAKAGE RATE TEST FINAL REPORT HOPE CREEK GENERATING STATION DOCKET NO. 50-354 Public Service Electric and Gas Company (PSE&G) hereby submits to the Nuclear Regulatory Commission (NRC) the Final Report for the Primary Reactor Containment Preoperational Integrated Leakage Rate Test (ILRT) in accordance with 10 CFR 50 Appendix J Section V.B.

This preoperational test was successfully concluded on January 3, 1986 and consisted of the ILRT, a supplemental verification test and the drywell to suppression chamber bypass test.

This report addresses the primary containment ILRT and the drywell to suppression chamber bypass test.

Should you have any questions on the subject filing, do not hesitate to contact us.

Sincerely, 8604090105 B MSOOO354 PDR ADOCK PDR A

Attachment

\\

Y t \\

l

_____________d

Director of Nuclear 2

4-7-86 Reactor Regulation C

D.H. Wagner USNRC Licensing Project Manager R.W.

Borchardt USNRC Senior Resident Inspector l