ML20078S258

From kanterella
Jump to navigation Jump to search
Submits Info Re Forthcoming Shipment of Irradiated Nuclear Reactor Fuel to New Hill,Nc by Util,In Accordance w/10CFR73.37
ML20078S258
Person / Time
Site: Harris, Brunswick  Duke Energy icon.png
Issue date: 02/13/1995
From: Cowan J
CAROLINA POWER & LIGHT CO.
To: Stroud T
NORTH CAROLINA, STATE OF
References
NUDOCS 9502240060
Download: ML20078S258 (3)


Text

.

' . a 050003cN3 90ll

@NL 9 al f/Z8 CONTAINS INFORMATION Carolina Power & Ught Company 3- , !e

.v: w.

w __ sqmm.3fl"grM SAFEGUARDS INFORMATION Brunswick Steam Electric Plant P. O. Box 10429 g g/ g-Southport, NC 28461 02-13-95 FILE: B10-13020

{If 0N dM,iNiib s,E dii,%!(ii,M. i 4,,;a, a W,, 4 l ;g; First Sergeant Terry C. Stroud Hazardous Material Coordinator

} CC3[g J k[_

North Carolina State Highway Patrol 512 North Salisbury Street P. O. Box 27687 Raleigh, No 27611-7687 1

i

Dear First Sergeant Terry C. Stroud:

In accordance with 10CFR73.37, the following information is provided concerning a forthcoming shipment of irradiated nuclear reactor fuel by CP&L.

1. Name. Address, and Telephone Number of Shinoer, Carrier, and Receiver:
a. Shipper: Brunswick Nuclear Project Docket Nos. 50-325 and 50-324 P. O. Box 10429 Southport, NC 28461 (910) 457-2201
b. Carriers: CSX Transportation U. S. Army Chief Dispatcher Military Ocean Terminal 3019 Warrington Street Sunny Point Jacksonville, FL 32205 Southport, NC 28461-5000 (904) 381-2780 (910) 341-8315 c: Receiver: Harris Nuclear Project Docket No. 50-400 P. O. Box 165 New Hill, NC 27562 (919) 362-2157
2. Description of Shioment - Radioactive material in IF-300 series shipping cask (s) : Cask ID NO. USA /9001/B () F; s/n

/

IF-303, s/n IF/304. 4

a. Cask (s) used this shipment: IF-303 AND IF-304 1 0 9502240060 950213 CONTAINS li.'FORMATl0N 1 PDR ADOCK 05000324 or " .'

P PDR W . p:,

SAFEGUARDS !MORMATION

First Sergeant Terry 02-13-95

b. Proper Shipping Name: Radioactive Material, Fissile, N.O.S.,7, RQ
c. DOT Hazard Class: Radioactive Material; Fissile I
d. DOT ID No.: UN2918
e. DOT Subtype: Highway route controlled quantity
f. Mode of Shipment: Rail
g. Physical Form: Solid
h. Chemical Form: Plutonium dioxide and uranium dioxide
i. Radionuclides: Pu-239, Pu-241, U-235, U-238, and mixed fission products
j. Original Enrichment: IF-303 2.75 MAX IF-304 2 . 8 3 WUC
k. Hazardous Material Quantity: IF-303 10251 lbs. Est.

IF-304 10251 lbs. Est.

1. Total Curie Content: IF-303 9.332.E+5 Est.

IF-304 9.353 E+5 Est.

m. Transport Index: IF-303 35.0 Est.

IF-304 35.0 Est.

n. Category of Label: Radioactive Yellow III
o. Type of Reactor: BWR
3. Route Within the State of North Carolina
a. Brunswick Nuclear Project to Leland, NC: Sunny Point Military Ocean Terminal Railroad
b. Leland, NC to Hamlet, NC: CSX Railroad
c. Hamlet, NC to Harris Nuclear Project: CSX Railroad By copy of this correspondence, the Nuclear Regulatory Commission is provided notification of this shipment.

d In accordance with 10CFR73.21 and 10CFR73.37, the information on the attached is designated as safeguards information and shall be protected in accordance with provisions of 10CFR73.21.

b 3 John P. Cowan  !

Director Site Operations Brunswick Steam Electric Plant GLW/pna I

I l

}

6 Attachment First Sergeant Terry C. Stroud 02-13-95 cc: (1) U.S. Nuclear Regulatory Commission ATTN: Mr. John Cook

  • Storage & Transport Systems Branch Mail Stop: TWFN 8 F-5 Washington D.C. 20555 (2) Regional Administrator U.S. Nuclear Regulatory Commission Region II ATTN: Mr. David R. McGuire PO BOX 2257 Atlanta, GA 30323 (3) Mr. Robert Kunita l

l

- - - - -