Submits Notification of Upcoming Shipment of Radioactive Matl in IF-300 Series Shipping Cask from Southport,Nc to New Hill,Nc
ML20117K823
Person / Time
Site: Brunswick  
Issue date: 05/02/1996
From: Levis W
CAROLINA POWER & LIGHT CO.
To: Stroud T
NORTH CAROLINA, STATE OF
References
B10-13020, NUDOCS 9606120284
Download: ML20117K823 (3)


Text

f.

066003Dylf10f a a,gp

&9Mo t-CONTAINS INFORMATV"!

Brunswick Nuclear Plant DN!bb 1b P. O. Box 10429 SAFEGUARDS INFORMAwi Southport, NC 28461 05-02-96 FILE:

B10-13020 i

First Sergeant Terry C.

Stroud Hazardous Material Coordinator North Carolina' State Highway Patrol' 512 North Salisbury Street j

P. O. Box 27687 Raleigh, NC 27611-7687 Dear First Sergeant Terry C.

Stroud:

In accordance with 10CFR73.37, the following information in provided concerning a forthcoming shipment of irradiated. nuclear reactor fuel by CP&L.

)

1.

Name. Address, and Telephone Number of Shioper. Carrier.-and Receiver-a.

Shipper:

Brunswick Nuclear Plan Docket Nos. 50-325 d 50-324 P. O. Box 10429 j

4 Southport, NC.28461 (910)~ 457-2375-

'b.

Carriers: CSX Transportation U.

S. Army Chief Dispatcher Military Ocean Terminal 3019 Warrington Street Sunny Point Jacksonville, FL 32205 Southport, NC 28461-5000 (904) 381-2780 (910) 341-8315 c: Receiver: Harris Nuclear Plant Docket No. 50-400 P.

O.

Box 165 New Hill, NC 27562 (919) 362-2157 2.

Description of Shipment - Radioactive material in IF-300 series shipping cask (s) :

Cask ID NO. USA /9001/B () F; s/n IF-303, s/n IF/304.

l a.

Cask (s) used this shipment:

IF-303 AND IF-304 i

b i

120030 O

WHEN SEPAR?TED FROM ENCLOSURES 9606120284 960502

.E THIS DOCUMENT AS DECONTNOLLED D

PDR ADOCK 05000324 F

PDR

k l;*;{,

^

<4 l

First Sergeant Terry C.

Stroud 05-02-96 l

b.

Proper Shipping Name: Radioactive Material, Fissile, N.O.S.,7, RQ c.

DOT Hazard Class: Radioactive Material; Fissile d.

DOT ID No.:

UN2918 e.

DOT Subtype: Highway route controlled quantity l

f.

Mode of' Shipment: Rail i

g.

Physical Form: Solid

)

h.

Chemical Form: Plutonium oxide and uranium oxide 1.

Radionuclides: Am-241,Pu-238,Pu-241,Pu-240,Cm-244, Pu-239,Sr-90.

j.

Original Enrichment:

IF-303 3.01 IF-304 3.01 i

k.

Hazardous Material Quantity: IF-303 10251 lbs.

Est.

IF-3C4 10251 lbs.

Est.

1.

Total Curie Content:

IF-303 1.726 E+6 Est.

IF-304 1.519 E+6 Est.

m.

Transport Index:

IF-303 30.0 Est.

IF-304 30.0 Est.

n.

Category of Label:

Radioactive Yellow III o.

Type of Reactor:

BWR 3.

Route Within the State of North Carolina l

1 a.

Brunswick Nuclear. Plant to Leland, NC:

Sunny Point Military Ocean Terminal. Railroad b.

Leland, NC to Hamlet, NC:

CSX Railroad c.

Hamlet, NC to Harris Nuclear Plant:

CSX Railroad By copy of this corresponder.

the Nuclear Regulatory Commission is provided notification of this -hipment.

.In accordance with 10CFR73.21 and iOCFh73.37, the information on the attached is designate d as safeguarde in armation and shall be protected in accordance with provisions of 10CFR73.21.

O R /t William Levis l

^

Director Site Operations Brunswick Nuclear Plant

I DBH/pna j

Attachment I

l First Sergeant Terry C.

Stroud 05-02-96 cc:

(1)

U.S. Nuclear Regulatory Commission ATTN: Ms. Gloria Bennington NMSS:SFPO-MS: OWFN-6 F-18 Washington D.C.

20555 (2)

Regional Administrator U.S. Nuclear Regulatory Commission Region II ATTN:

Bill Tobin PO BOX 2257 Atlanta, GA 30301 (3)

Mr. Robert Kunita CP&L OHS 9B5 410 South Wilmington Street Raleigh, NC 27601 (4)

Mr. Ed Wills (Zone 5)

Harris Nuclear Plant State Road 1135 New Hill, NC 27562 l