A O S000 SMy(3 0l gpgg aauzo L Raa/A Carolina Power & Light Company CONTAINS INFORMATION Brunswick Nuclear Plant

l['jCH $

P. O. Box 10429 Southport, NC - 28461 SAFEGUARDS INFOR.MATION 11-17-95 FILE:

B10-13020 First Sergeant Terry C. Stroud Hazardous Material Coordinator Wndi oar.L FROM ENCLOSURES, North Carolina State Highway Patrol HANDLE THIS D0'.:UMENT AS DECONTROLLED 512 North Salisbury Street 1

P. O.

Box 27687 Raleigh, NC 27611-7687 Dear First Sergeant Terry C.

Stroud:

In accordance with 10CFR73.37, the following information is provided concerning a forthcoming shipment of irradiated nuclear reactor fuel by CP&L.

1.

Name, Address, and Telephone Number of Shinner, Carrier, and Receiver:

a.

Shipper:

Brunswick Nuclear Plant Docket Nos. 50-325 and 50-324 P.

O. Box 10429 Southport, NC 28461 (910) 457-2201

b. Carriers: CSX Transportation U.

S. Army Chief Dispatcher Military Ocean Terminal 3019 Warrington Street Sunny Point Jacksonville, FL 32205 Southport, NC 28461-5000 (904) 381-2780 (910) 341-8315 c: Receiver: Harris Nuclear Plant Docket No. 50-400 P. O. Box 165 New Hill, NC 27562 (919) 362-2157 2.

Description of Shipment - Radioactive material in IF-300 series shipping cask (s):

Cask ID NO. USA /9001/B () F; s/n IF-303, s/n IF/304.

a.

Cask (s) used this shipment:

IF-303 AND IF-304 N0

_7.

._0 s

\\,

PDR XPORT CENERAL PDR


a

4 s -.

First Sergeant Terry C. Stroud 11-17-95 i

b.

Proper Shipping Name: Radioactive Material, Fissile, N.O.S.,7, RQ c.

DOT Hazard Class:. Radioactive Material; Fissile I d.

DOT ID No.:

UN2918 e.

DOT Subtype: Highway route controlled quantity f.

Mode of Shipment: Rail g.

Physical Form: Solid h.

Chemical Form: Plutonium dioxide and uranium dioxide i.

Radionuclides: Pu-239, Pu-241, U-235, U-238, and mixed fission products j.

Original Enrichment:

IF-303 3.00 MAX IF-304 2.12 MAX k.

Hazardous Material Quantity: IF-303 10251 lbs.

Est.

IF-304 10251 lbs.

Est.

1.

Total Curie Content:

IF-303 1.420 E+6 Est.

IF-304 7.208 E+5 Est.

m.

Transport Index:

IF-303 40.0 Est.

IF-304 40.0 Est.

n.

Category of Label:

Radioactive Yellow III o.

Type of Reactor:

BWR 3.

Route Within the State of North Carolina a.

Brunswick Nuclear Plant to Leland, NC:

Sunny Point Military Ocean Terminal Railroad b.

Leland, NC to Hamlet, NC:

CSX Railroad c.

Hamlet, NC to Harris Nuclear Plant:

CSX Railroad By copy of this correspondence, the Nuclear Regulatory Commission is provided notification of this shipment.

In accordance with 10CFR73.21 and 10CFR73.37, one information on the attached is designated as safeguards information and shall be protected in accordance with provisions of 10CFR73.21.

9 I

1 William Levis Director Site Operations Brunswick Nuclear Plant DBH/pna

Attachment, i'

First Sergeant Terry C. Stroud 11-17-95 cc:

(1)

U.S. Nuclear Regulatory Commission ATTN:

Mr. John Cook Storage & Transport Systems Branch Mail Stop: TWFN 8.F-5 Washington D.C.

20555 (2)

Regional Administrator U.S.

Nuclear Regulatory Commission Region II ATTN:

Bill Tobin PO BOX 2257 Atlanta, GA 30301 (3)

Mr. Robert Kunita 1

4 a