._

L 39/9 %

O SO O 00 M W O/'

CP&L CONTAINS INFORMATION "lHlf>'H IS-Carolina Power & Ught Company 3kh,b, f40RM d"'

.v-m m ra Brunswick Nuclear Plant P. O. Box 10429 Southport, NC 28461 WilEN SEPARATr0 FROM ENCLOSURES, 09-25-95

UNDLE THG DnCI' MENT AS DECONTRC!!.m FILE

B10-13020 First Sergeant Terry C. Stroud Id-5 Hazardous Material Coordinator North Carolina State Highway Patrol 512 North Salisbury Street P. O.

Box 27687 Raleigh, NC 27611-7687 Dear First Sergeant Terry C.

Stroud:

In accordance with 10CFR73.37, the following information is provided concerning a forthcoming shipment of irradiated nuclear reactor fuel by CP&L.

1.

Name, Address, and Telechone Number of Shioner, Carrier, and Receiver:

a.

Shipper:

Brunswick Nuclear Plant Docket Nos. 50-325 and 50-324 P.

O.

Box 10429 Southport, NC 28461 (910) 457-2201 b.

Carriers: CSX Transportation U.

S. Army Chief Dispatcher Military Ocean Terminal 3019 Warrington Street Sunny Point Jacksonville, FL 32205 Southport, NC 28461-5000 (904) 381-2780 (510) 341-8315 c: Receiver: Harris Nuclear Plant Docket No. 50-400 P.

O.

Box 165 New Hill, NC 27562 i

(919) 362-2157 2.

Descriotion of Shioment - Radioactive material in IF-300 series shipping cask (s):

Cask ID NO. USA / 9001/B () F; s/n IF-303, s/n IF/304.

l a.

Cask (s) used this shipment:

IF-303 AND IF-304 9510100069 950925 4

PDR ADOCK 05000324 x

l hi F

PDR OG0031 1

. " (.

J.

(~ '.

First Sergeant Terry.C. Stroud 09-25-95

b.. Proper Shipping Name: Radioactive Material, Fissile, N.O.S.,7, RQ c.

DOT Hazard Class: Radioactive Material; Fissile I I

d.

DOT ID Noi:

UN2918 e.

DOT Subtype:. Highway route controlled quantity f.

Mode of Shipment: Rail g.

Physical Form: Solid h.

Chemical Form: Plutonium dioxide and uranium dioxide i.. Radionuclides: Pu-239, Pu-241, U-235, U-238', and mixed fission products j.

Original Enrichment:

IF-303 3.01 MAX IF-304 3.01 MAX k.

Hazardous Material Quantity: IF-303 10251 lbs.

Est.

4 IF-304 10251 lbs.

Est.

1 1.

Total Curie Content:

IF-303 2.164 E+6 Est.

-IF-304 1.904 E+6 Est.

m.

Transport Index:

IF-303 35.0 Est.

IF-304 35.0 Est.

n.

Category of Label:

Radioactive Yellow III

.o.

Type of Reactor:

BWR 4

3.

Route Within the State of North Carolina a.

' Brunswick Nuclear Plant to Leland, NC:

Sunny Point Military Ocean Terminal Railroad b.

Leland, NC to Hamlet, NC:

CSX Railroad c.

Hamlet, NC to Harris Nuclear Plant:

CSX Railroad By copy of this correspondence, the Nuclear Regulatory Commission is provided notification of this shipment.

In accordance with 10CFR73.21 and 10CFR73.37, the information on the attached is designated as safeguards information and shall be protected in accordance with provisions of 10CFR73.21.

t I

William Levis Director Site Operations Brunswick Nuclear Plant DBH/pna A

~..

~

]~<

I e

4

>Attachmenti i

P'irst Sergeant Terry C. Stroud. 09-25-95 i

4 1

~

Nuclear Regulatory Commission l

occ:

~(1)

U.S.

ATTN:

Mr.-John Cook i

Storage &. Transport Systems Branch j;

. Mail Stop': TWFN 8 F-5 1

Washington D.C. 20555 2

~

(2).

U.S. Nuclear Regulatory Commission Regional' Administrator Region II 1

ATTN:

Mr. David R. McGuire PO BOX 2257 Atlanta, GA 30301 d

r

'(3)

Mr. Robert Kunita l

j s

+

5 i

i 9

~

s t

i i

h W

TP

+*F' M-es-