gprov mG SEPARATED FROM g;Cio UNS HAnou mis occuuan As c,rcomiouED' WHICH IS-Carolina Power & Light Company ]Q{ggg g{ggg 0 S000 SW) ScoY Brunswick Steam Electric Plant

/

P. O.

Box 10429 Q -3 ;;tg Southport, NC 28461 3// DIE 6-29-94 FILE:

B10-13020 First Sergeant Terry C.

Stroud Hazardous Material Coordinator North Carolina State Highway Patrol 512 North Salisbury Street P.

O.

Box 27687 Raleigh, NC 27611-7687 Dear First Sergeant Terry C.

Stroud:

In accordance with 10CFR73.37, the following information is provided concerning a forthcoming shipment of irradiated nuclear reactor fuel by CP&L.

1.

Name, Address, and Telechone Number of Shioner, Carrier, and Receiver:

a.

Shipper:

Brunswick Nuclear Project Docket Nos. 50-325 and 50-324 P.

O.

Box 10429 Southport, NC 28461 (919) 457-2201 b.

Carriers: CSX Transportation U.

S. Army Chief Dispatcher Military Ocean Terminal 3019 Warrington Street Sunny Point Jacksonville, FL 32205 Southport, NC 28461-5000 (904) 381-2780 (919) 341-8315 c: Receiver: Harris Nuclear Project Docket No. 50-400 P.

O.

Box 165 New Hill, NC 27562 (919) 362-2157 2.

Descriotion of Shioment - Radioactive material in IF-300 series shipping cask (s)-

Cask ID NO. USA / 9001/B () F; s/n IF-303, s/n IF/304.

a.

Cask (s) used this shipment:

IF-303 AND IF-304 i

01 'in e -

h l

9408020183 940629 0

l PDR ADOCK 03000324 P

PDR l

\\-

I.

6 66C0 -3273gc, First Sergeant Terry C.

Stroud 6-29-94 b.

Proper Shipping Name: Radioactive Material, Fissile, N.O.S.,

RQ c.

DOT Hazard Class: Radioactive Material; Fissile I d.

DOT ID No.:

UN2918 e.

DOT Subtype: Highway route controlled quantity f.

Mode of Shipment: Rail g.

Physical Form: Solid h.

Chemical Form: Plutonium dioxide and uranium dioxide i.

Radionuclides: Pu-239, Pu-241, U-235, U-238, and mixed fission products j.

Original Enrichment:

IF-303 2.86 MAX IF-304 2.86 MAX k.

Hazardous Material Quantity: IF-303 10251 lbs.

Est.

IF-304 10506 lbs.

Est.

1.

Total Curie Content:

IF-303 1.167 E+6 Est.

IF-304 1.193 E+6 Est.

m.

Transport Index:

IF-303 35.0 Est.

IF-304 35.0 Est.

n.

Category of Label:

Radioactive Yellow III o.

Type of Reactor:

BNR 3.

Route Within the State of North Carolina a.

Brunswick Nuclear Project to Leland, NC:

Sunny Point Military Ocean Terminal Railroad b.

Leland, NC to Hamlet, NC:

CSX Railroad c.

Hamlet, NC to Harris Nuclear Project:

CSX Railroad By copy of this correspondence, the Nuclear Regulatory Commission is provided notification of this shipment.

In accordance with 10CFR73.21 and 10CFR73.37, the informar. ion on the attached is designated as safeguards information and shall be protected in accordance with provisions of 10CFR73.21.

JdbI/'

John P.

Cowan Director Site Operations Brunswick Steam Electric Plant GLW/pna

D$000 Sc

.50 0l Att'achment

_)

i First Sergeant Terry C.

Stroud 6-29-94 j

cc:

(1)

U.S.

Nuclear Regulatory Commission ATTN:

Mr. John Cook Storage & Transport Systems Branch Mail Stop: TWFN 8 F-5 Washington D.C.

20555 t

(2)

Regional Administrator U.S.

Nuclear Regulatory Commission Region II ATTN:

Mr. David R. McGuire 101 Marietta St.,

NW Atlanta, GA 30323 (3)

Mr. Robert Kunita t

V f

{

i i

r i

7 ve -, - - - - -

,.n-.

-,