i

'J'.

050oo 3a ya 3 e M

E Bninswick Nuclear Plant P.O. Box 10429 CONTAINS INFORMATION CP&L southeort u.c. 2846' w HicH is-SAFMARM INF0k@ TIO December 02,1998 s

Sergeant Mark Dalton p4 d Ilazardous Material Coordinator M

North Carolina State liighway Patrol

.%W}

W l

P.O. Box 29590 nj Raleigh, NC 27626 - 0590 e,;

Dear Sergeant Dalton:

j In accordance with 10 CFR73.37, the following information is provided concerning a forthcoming shipment of irradiated nuclear reactor fuel by CP&L.

~

j

l. Name Address. and Telephone Number of Shipper. Carrier. and Receiver:

WHEN SEFARATED FF,0M ENCLOSURES, QUSDLE THIS DOCUMENT AS DE

a. Shipper:

Brunswick Nuclear Plant Jl Docket Nos. 50-325 and 50-324 P.O. Box 10429 Southport, NC 28461 i

(910)457-2375

b. Carriers:

CSX Transportation U.S. Army Chief Dispatcher Military Ocean Terminal 3019 Warrington St.

Sunny Point Jacksonville. FL 32205 Southport, NC 28461-5000 (904)381-2780 (910)341 8315

c. Receber:

liarris Nuclear Plant Dockei No. 50-400 5413 Shearon Harris Rd.

i New Ilill, NC 27562 (919) 362-2157

2. Description of Shinment - Radioactive material in IF-300 series shipping cask (s)-

Cask ID No. USA /9001/B( )F, s/n IF 303, s/n IF-304.

a. Cask (s) Used This Shipment:

IF 303,IF-304

b. Proper Shipping Name:

Radioactive Material Fissile, N.O.S.,(7)RQ

c. DOT llaxarc' Class:

Radioactive Material, Fissile

d. DOT ID No.:

UN2918

e. DOT Subtype:

Ilighway Route Controlled Quantity

f. Mode of Shipment:

Rail

g. Physical Form:

Solid

h. Chemical Form:

Plutonium Oxide and Uranium Oxide g

i. Radionuclides:

Am-241 Pu-238. Pu-241 Pu 240, Cm 244, Pu-239, Sr-90

)

j. Original Enrichment:

IF-303:

2.75 IF-3N:

2.76 L. liarardous Material Quantity:

IF-303:

10.251 1.bs. listimated l

IF-304:

10,251 Lbs. listimated I. Total Becquerel / Curie Content:

IF-303:

2.584 E4 TBq 6.983E5 Curies IF-304:

2.529E4 TBq 6.835E5 Curies 9812220035 981202 PDR ADOCK 05000324 F

PDR

~~

s

_ _. ~. _ _ -. _ _ _. _ _ _.. _.. _.

l,i: ; o Brunswick Nuclear Plant I

P.O. Box 10429' Southport N.C. 28461 l

'. Sergeant Mark Dalton 2

12/02/1998 L

l-l L

m. Transport index:

IF-303:

30 Estimated -

IF.304:

30 Estimated

n. Category of Label:'

Radioactive Yellow Ill

o. Type of Reactor:

BWR-3.

Route Within the State of North Carolina a; Brunswick Nuclear Plant to Leland, NC: Sunny Point Military Ocean Terminal Railroad b.

Leland, NC to llamlet, NC: CSX Rai oad I

c.

Hamlet, NC to liarris Nuclear Plant: CSX Railroad By copy of this correspondence, the Nuclear Regulatory Commission is provided notification of this shipment.

In accordance with 10CFR73.21 and 10CFR7,3.37, the information on the attachment is designated as

safeguards information and shall be protected in accordance with the provi, ions of 10CFR73.21.

[

l t.)

t',

+

\\

J. S. Keenan Vice President Brunswick Nuclear Plant l

DBH/dbh 1

Attachment.

)

l cc:

(1)

U.S. Nuclear Regulatory Commission (3) Director, Division of Industrial.

Spent Fuct Project Office and Medical Nuclear Safety 11555 Rockville Pike 11545 Rockville Pike Rockville, MD 20852-2738 Rockville, MD 20852 2738 (2) liarris Nuclear Plant

.. Denny Braund llarris Security 5413 Shearon liarris Rd.'

New Hill, NC 27562

)

l i

['

V i

-e op

+

7 e

.+

m. 5.w w a v

w>-

---..-e-7

-T-2---

s

.+