- 1 O O.0 3 M M O

,1 4

39 / d% W*

CONTAINS INFORB CP&L bS INFORMATION

~"~

SAFE

/

7 a,

Carolina Power & Light Company g

lhtQG$ any(cryyp[g h

TD

...s.

n ha 6, n ad,

Brunswick Steam Electric Plant company corresooncence P. O.

Box 10429 Southport, NC 28461 fh h 12-09-94 bO()Cg FILE:

B10-13020 First Sergeant Terry C.

Stroud Hazardous Material Coordinator North Carolina State Highway Patrol 512 North Salisbury Street P.

O.

Box 27687 Raleigh, NC 27611-7687 Dear First Sergeant Terry C.

Stroud:

In accordance with 10CFR73.37, the following information is provided concerning a forthcoming shipment of irradiated nuclesr reactor fuel by CP&L.

1.

Name, Address, and Telechone Number of Shicoer, Carrier, and Receiver:

a.

Shipper:

Brunswick Nuclear Project Docket,Nos. 50-325 and 50-324 P.

O.

Box 10429 Southport, NC 28461 (910) 457-2201

b. Carriers: CSX Transportation U.

S.

Army Chief Dispatcher Military Ocean Terminal 3019 Warrington Street Sunny Point Jacksonville, FL 32205 Southport, NC 28461-5000 (904) 381-2780 (910) 341-8315 c: Receiver: Harris Nuclear Project Docket No. 50-400 P.

O.

Box 165 New Hill, NC 27562 (919) 362-2157 2.

Description of Shioment - Radioactive material in IF-300

/

series shipping cask (s).

Cask ID NO. USA / 9001/B () F ; s/n Q

IF-303, s/n IF/304.

h I

D a.

Case: (s) used this shipment:

IF-303 AND IF-304 9501030059 941209 pg%

DR ADOCK 0500 4

~

A j 5

>V First Sergeant Terry C.

Stroud 12-09-94 b.

Proper Shipping Name: Radioactive Material, Fissile, N.O.S.,7, RQ c.

DOT Hazard Class: Radioactive Material; Fissile I d.

DOT ID No.:

UN2918 e.

DOT Subtype: Highway route controlled quantity f.

Mode of Shipment: Rail

~

g.

Physical Form: Solid h.

Chemical Form: Plutonium dioxide and uranium dioxide i.

Radionuclides: Pu-239, Pu-241, U-235, U-238, and mixed fission products j.

Original Enrichment:

IF-303 2.99 MAX IF-304 3.00 MAX k.

Hazardous Material Quantity: IF-303 10251'lbs.

Est.

IF-304 10251 lbs.

Est.

1.

Total Curie Content:

IF-303 2.388 E+6 Est.

IF-304 2.437 E+6 Est.

m.

Transport Index:

IF-303 35.0 Est.

IF-304 35.0 Est.

n.

Category of Label:

Radioactive Yellow III o.

Type of Reactor:

BWR 3.

Route Within the State of North Carolina a.

Brunswick Nuclear Project to Leland, NC:

Sunny Point Military Ocean Terminal Railroad b.

Leland, NC to Hamlet, NC:

CSX Railroad c.

Hamlet, NC to Harris Nuclear Project:

CSX Railroad By copy of this correspondence, the Nuclear Regulatory Commission is provided notification of this shipment.

In accordance with 10CFR73.21 and 10CFR73.37, the information on the attached is designated as safeguards information and shall be protected in accordance with provisions of 10CFR73.21.

k S w' John P.

Cowan Director Site Operations Brunswick Steam Electric Plant Gild /pna

~

(

a

~

\\

Attachment First Sergeant Terry C.

Stroud 12-09-94 cc:

(1)

U.S.

Nuclear Regulatory Commission ATTN:

Mr. John Cook Storage & Transport Systems Branch Mail Stop: TWFN 8 F-5 Washington D.C.

20555 (2)

Regional Administrator U.S.

Nuclear Regulatory Commission Region II ATTN:

Mr. David R. McGuire PO BOX 2257 Atlanta, GA 30323 (3)

Mr. Robert Kunita