0500039ysocy a a tazo L.aaa.qq CONTAINS INFORMATION

'I c wo.:

T Carolina Power & Ught Company v>:G 3AFEGUARDS li&ORMATION

"==a ="

Brunswick Nuclear Plant P.O. Box 10429 Southport N.C.

28461 05-28-96 FILE:

B10-13020 First Sergeant Terry C.

Stroud b

Hazardous Material Coordinator North Carolina State Highway Patrol P.

O.

Box 27687 Raleigh, NC 27611-7687 Dear First Sergeant Terry C.

Stroud:

In accordance with 10CFR73.37, the following informatior. is provided concerning a forthcoming shipment of irradiated nuclear reactor fuel by CP&L.

1.

Name. Address. and Telechone Number of Shipoer. Ca rri er. and Receiver

a. Shipper:

Brunswick Nuclear Plant Docket Nos. 50-325 and 50-324 P.

O.

Box 10429 Southport, NC 28461 (910) 457-2375

b. Carriers: CSX Transportation U.

S. Army Chief Dispatcher Military Ocean Terminal 3019 Warrington Street Sunny Point Jacksonville, FL 32205 Southport, NC 28461-5000 (904) 381-2780 (910) 341-8315 c: Receiver: Harris Nuclear Plant Docket No. 50-400 P.

O.

Box 165 New Hill, NC 27562 (919) 362-2157 2.

Descriotion of Shioment - Radioactive material in IF-300 series shipping cask (s) :

Cask ID NO. USA /9001/B () F; s/n IF-303, s/n IF/304.

t0 A

a.

Cask (s) used this shipment:

IF-303 AND IP-304

~

090024 w'ttil SEPARATED FROM ENCLOSURES, N

{lAIjDLE ItllS DOCU!aENT AS DECONTROLLED 9607090064 960528 PDR ADOCK 05000324 P

PDR

/.

b First Sergeant Terry C. Stroud 05-28-96 b.

' Proper: Shipping Name: Radioactive Material, Fissile, N.O.S.,7,,RQ-c.

DOT Hazard Class: Radioactive Material; Fissile d.

DOT ID-No.:

UN2918 e.

DOT Subtype: Highway Route Controlled Quantity f.

' Mode of Shipment: Rail g.

Physical' Form: Solid-h.

Chemical Form: Plutonium Oxide and Uranium Oxide j

i.

Radionuclides: Am-241,Pu-238,Pu-241,Pu-240,Cm-244,

~

Pu-239,Sr-90.

j.

Original Enrichment:

IF-303 3.00

)

IF-304 3.00 k.

Hazardous Material Quantity: IF-303 10251 lbs.

Est.

IF-304 10251 lbs.

Est.

i 1.

Total Curie Content:

IF-303 1.565 E+6 Est.

i

~

IF-304 1.625 E+6

____Est.

m.

Transport;Index:

IF-303 30.0

_.,__Est.

IF-304 30.0 Est.

n.-

Category of Label:

Radioactive Yellow III o.

Type of Reactor:

BWR j

i 3.

Route Within the State of North Carolina a.

Brunswick Nuclear Plant to Leland, NC:

Sunny Point l

Military Ocean Terminal Railroad b.

Leland, NC to Hamlet, NC:

CSX Railroad 1

c.

Hamlet, NC to Harris Nuclear Plant:

CSX Railroad

)

By' copy of this correspondence, the Nuclear Regulatory Commission is provided notification of this shipment.

1 In accordance with 10CFR73.21 and 10CFR73.37, the information on the attached is designated as safeguards information and shall be i

protected.in accordance with provisions of 10CFR73.21.

William Levis Director Site Operations Brunswick Nuclear Plant DBH/pna Attachment

]

/*

First Sergeant Terry C. Stroud 05-28-96 cc:

(1)

U.G. Nuclear Regulatory Commission ATTN: Ms. Gloria Bennington NMSS:SFPO-MS: OWFN-6 F-18 Washington D.C.

20555 (2)

Mr. Robert Kunita CP&L OHS 9B5 410 South Wilmington Street Raleigh, NC 27601 (3)

Mr. Ed Wills (Zone 5)

Harris Nuclear Plant State Road 1135 New Hill, NC 27562 ATTACHMENT