__
e
@&L Carolina Power & Light Company
.h September 20, 1982 Mr. Jim Van Vliet l
Office of Nuclear Reactor Regulation United States Nuclear Regulatory Commission Washington, DC 20555 BRUNSWICK STEAM ELECTRIC PLANT, UNIT NOS. 1 AND 2 DOCKET NOS. 50-325 AND 50-324 LICENSE NOS. DPR-71 AND DPR-62 SEISMIC ANALYSIS
Dear Mr. Van Vliet:
This confirms the results of our meeting of September 10, 1982 as follows:
1.
Steam Relief Valve Line No. 124 Carolina Power & Light Company (CP&L) presented a seismic analysis of this line, which demonstrated that three snubbers could be considered long term fixes. Based on the analysis presented at the meeting, which will be documented in a written report, NRC-NRR agreed that these three snubbers can be considered as long term fixes, and will not require repair prior to startup.
2.
Main Steam Line Inside Drywell Carolina Power & Light Company analysis of this line concluded that it was reasonable to assign long term fix-category to one snubber on this line. However, in that there appeared to be sufficient time for modification of this snubber prior to startup, CP&L committed to complete appropriate modifications prior to startup.
3.
Main Steam and Feedwater Lines Outside Drywell Carolina Power & Light Company analysis of these lines con-cluded it was reasonable to assign long term fix category, however, in that it appeared that modifications could be completed (subject to confirmation that materials were availabic) CP&L committed to complete these modifications prior to startup.
Should the status change during modification of items 2 and 3 O
above, CP&L would need to present further engineering justification for NRC-NRR concurrence, before these items could be reconsidered as long term fixes.
8209230095 820920 PDR ADOCK 05000324 P
PDR 411 Fayetteville Street
- P O. Box 1551
- Haleigti, N. C. 27602
s Mr. Van Vliet September 20, 1982 A follow-up letter which documents our presentation on Steam Relief Valve Line 124 will be forwarded to you shortly.
Yours very truly, f
' J!!me-S.
. Zimmerman Manager Licensing & Permits SRZ/1r (5274) cc:
Mr. D. O. Myers (NRC-BSEP)
Mr. J. P. O'Reilly (NRC-RII)
Mr. J. A. Van Vliet (NRC) k