IR 05000263/1990013
ML20055G432 | |
Person / Time | |
---|---|
Site: | Monticello ![]() |
Issue date: | 07/18/1990 |
From: | Creed J, Madeda T NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
To: | |
Shared Package | |
ML20055G430 | List: |
References | |
50-263-90-13, NUDOCS 9007230170 | |
Download: ML20055G432 (1) | |
Similar Documents at Monticello | |
---|---|
Category:INSPECTION REPORT
MONTHYEARIR 05000263/19990061999-10-21021 October 1999
[Table view]Insp Rept 50-263/99-06 on 990813-0923.Non-cited Violations Noted.Major Areas Inspected:Operations,Engineering, Maintenance & Plant Support IR 05000263/19990121999-10-13013 October 1999 Insp Rept 50-263/99-12 on 990913-17.No Violations Noted. Major Areas Inspected:Various Aspects of RP Program Including Radioactive Waste Processing,Storage,Packaging & Transportation & General RP Practices IR 05000263/19990051999-09-0101 September 1999 Insp Rept 50-263/99-05 on 990702-0812.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering, Maint & Plant Support IR 05000263/19990041999-07-28028 July 1999 Insp Rept 50-263/99-04 on 990521-0701.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19990111999-07-14014 July 1999 Insp Rept 50-263/99-11 on 990621-24.No Violations Noted. Major Areas Inspected:Licensee Performance During Exercise of Emergency Plan IR 05000263/19990021999-05-0303 May 1999 Insp Rept 50-263/99-02 on 990223-0408.One Violation Occurred & Being Treated as non-cited Violation.Major Areas Inpsected:Operations,Engineering,Maint & Plant Support IR 05000263/19990101999-04-0909 April 1999 Insp Rept 50-263/99-10 on 990308-12.No Violations Noted. Major Areas Inspected:Review of Training Administrative Procedures & Operating Exam Matls & Observation & Evaluation of Licensed Operators IR 05000263/19990011999-03-11011 March 1999 Insp Rept 50-263/99-01 on 990112-0222.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000263/19980181999-01-20020 January 1999 Insp Rept 50-263/98-18 on 981201-990111.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19980191998-12-30030 December 1998 Insp Rept 50-263/98-19 on 981214-18.No Violations Noted. Major Areas Inspected:Review of Various Aspects of Licensees Chemistry & Radiation Protection Programs,Specifically REMP, PASS & Chemistry QC & Matl Condition IR 05000263/19980161998-12-14014 December 1998 Insp Rept 50-263/98-16 on 981014-1130.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support Re Performance of Emergency Preparedness Drill IR 05000263/19980171998-11-24024 November 1998 Insp Rept 50-263/98-17 on 981026-30.No Violations Noted. Major Areas Inspected:Physical Security Program IR 05000263/19980151998-11-10010 November 1998 Insp Rept 50-263/98-15 on 980821-1014.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000263/19980121998-09-18018 September 1998 Insp Rept 50-263/98-12 on 980719-0831.No Violations Noted. Major Areas Inspected:Opertions,Maint,Engineering & Plant Support IR 05000263/19980131998-09-11011 September 1998 Insp Rept 50-263/98-13 on 980810-13.No Violations Noted. Major Areas Inspected:Licensee Implementation of 10CFR50.65, Requirements for Monitoring Effectiveness of Maint at Nuclear Power Plants IR 05000263/19980141998-09-0404 September 1998 Insp Rept 50-263/98-14 on 980810-14.No Violations Noted. Major Areas Inspected:Licensee Liquid & Gaseous Effluents Program,Calibration & Testing of Area & Process Radiation Monitors & Free Release Program IR 05000263/19980111998-08-21021 August 1998 Insp Rept 50-263/98-11 on 980528-0718.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19980091998-07-30030 July 1998 Insp Rept 50-263/98-09 on 980511-0612.No Violations Noted. Major Areas Inspected:Review of 10CFR50.59 Safety Evaluation & Screening Activities IR 05000263/19980071998-06-25025 June 1998 Insp Rept 50-263/98-07 on 980413-0527.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maint & Plant Support IR 05000263/19980101998-05-26026 May 1998 Insp Rept 50-263/98-10 on 980427-30.No Violations Noted. Major Areas Inspected:Plant Support IR 05000263/19980061998-05-11011 May 1998 Insp Rept 50-263/98-06 on 980323-0423.No Violations Noted. Major Areas Inspected:Maint IR 05000263/19980041998-05-0808 May 1998 Insp Rept 50-263/98-04 on 980224-0414.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000263/19980081998-04-30030 April 1998 Insp Rept 50-263/98-08 on 980406-09.No Violations Noted. Major Areas Inspected:Radiation Protection Activities During Refueling & Maint Outage ML20216B2871998-04-0303 April 1998 Insp Rept 50-263/98-05 on 980309-13.Violations Noted.Major Areas Inspected:Physical Security Program ML20217A6881998-03-18018 March 1998 Insp Rept 50-263/98-02 on 980113-0223.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20216C1671998-03-0606 March 1998 Insp Rept 50-263/98-03 on 980209-13.Violations Noted.Major Areas Inspected:Various Aspects of Licensee RP Program Including Radwaste Processing,Packaging,Transportation & Implementation of Recent Changes to NRC & DOT Regulations IR 05000263/19970181998-02-0404 February 1998 Insp Rept 50-263/97-18 on 971125-980112.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20198G3171998-01-0606 January 1998 Page 6 of Plant Emergency Preparedness Exercise Insp Rept 50-263/97-16.Page Inadvertently Omitted W/Rept Transmitted by IR 05000263/19970161997-12-22022 December 1997 Insp Rept 50-263/97-16 on 971118-21.No Violations Noted. Major Areas Inspected:Evaluation of Performance During Plant Biennial Exercise of Emergency Plan by Regional EP Inspectors & Resident Inspector Staff from Plants ML20197B1731997-12-18018 December 1997 Insp Rept 50-263/97-15 on 971014-1124.Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000263/19970171997-12-15015 December 1997 Insp Rept 50-263/97-17 on 971118-21.No Violations Noted. Major Areas Inspected:General Radiation Protection Practices,Respiratory Protection Program & Radwaste Processing,Storage & Monitoring IR 05000263/19970141997-11-13013 November 1997 Insp Rept 50-263/97-14 on 970830-1013.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support.Rept Also Includes Insp follow-up of Security Related Issue by Regional Inspector IR 05000263/19970121997-09-18018 September 1997 Insp Rept 50-263/97-12 on 970708-0829.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19970111997-08-19019 August 1997 Insp Rept 50-263/97-11 on 970707-10.No Violations Noted. Major Areas Inspected:Installation of Emergency Core Cooling Sys Suction Strainers & pressure-suppression Chamber Coating Program IR 05000263/19970131997-08-14014 August 1997 Forwards Partially Withheld Insp Rept 50-263/97-13 on 970714-18 (Ref 10CFR73.21) IR 05000263/19970101997-07-23023 July 1997 Insp Rept 50-263/97-10 on 970623-27.No Violations Noted. Major Areas Inspected:Review of Issues Surrounding Licensee Discovery of Error in Head Loss Across ECCS Suction Strainers ML20149H9291997-07-17017 July 1997 Insp Rept 50-263/97-08 on 970528-0707.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19970091997-07-15015 July 1997 Insp Rept 50-263/97-09 on 970616-20.No Violations Noted. Major Areas Inspected:Licensees Chemistry & Radiation Protection Programs ML20141E8031997-06-18018 June 1997 Insp Rept 50-263/97-06 on 970412-0527.Violation Noted.Major Areas Inspected:Operations,Engineering,Maint & Plant Support IR 05000263/19970031997-05-0909 May 1997 Insp Rept 50-263/97-03 on 970220-0411.No Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000263/19970041997-04-14014 April 1997 Insp Rept 50-263/97-04 on 970310-14.No Violations Noted. Major Areas Inspected:Review of Training Administrative Procedures,Operating Exam Matl,Observation & Operating Exam, & Assessment of Simulator Fidelity ML20137K1881997-03-24024 March 1997 Corrected Pages 23,39,50 & 51 to Insp Rept 50-263/96-09,in Order to Correct Errors in Rept ML20137A1681997-03-11011 March 1997 Insp Rept 50-263/97-02 on 970109-0219.Violations Noted.Major Areas Inspected:Operations,Maint & Engineering ML20138N6991997-02-20020 February 1997 Insp Rept 50-263/96-09 on 961118-970108.Violations Noted. Major Areas Inspected:Maintenance,Engineering & Operations IR 05000263/19960121997-01-31031 January 1997 Insp Rept 50-263/96-12 on 961128-970108.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support ML20134G1611997-01-29029 January 1997 Insp Rept 50-263/96-11 on 961017-1127.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20133C4081996-12-27027 December 1996 Insp Rept 50-263/96-08 on 960829-1016.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000263/19960101996-11-0101 November 1996 Insp Rept 50-263/96-10 on 961028-1101.No Violations Noted. Major Areas Inspected:Status of Radiation Protection & Chemistry Controls IR 05000263/19960071996-10-0707 October 1996 Insp Rept 50-263/96-07 on 960721-0828.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20058H4431993-12-0606 December 1993 Rept 50-263/93-20 on 931202.Areas Discussed:Review of Circumstances Surrounding & Corrective Actions in Response to Licensee Identified Incident of Inadequate Storage & Marking of Safeguards Info at Plant 1999-09-01 Category:NRC-GENERATED MONTHYEARIR 05000263/19990061999-10-21021 October 1999
[Table view]Insp Rept 50-263/99-06 on 990813-0923.Non-cited Violations Noted.Major Areas Inspected:Operations,Engineering, Maintenance & Plant Support IR 05000263/19990121999-10-13013 October 1999 Insp Rept 50-263/99-12 on 990913-17.No Violations Noted. Major Areas Inspected:Various Aspects of RP Program Including Radioactive Waste Processing,Storage,Packaging & Transportation & General RP Practices IR 05000263/19990051999-09-0101 September 1999 Insp Rept 50-263/99-05 on 990702-0812.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering, Maint & Plant Support IR 05000263/19990041999-07-28028 July 1999 Insp Rept 50-263/99-04 on 990521-0701.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19990111999-07-14014 July 1999 Insp Rept 50-263/99-11 on 990621-24.No Violations Noted. Major Areas Inspected:Licensee Performance During Exercise of Emergency Plan IR 05000263/19990021999-05-0303 May 1999 Insp Rept 50-263/99-02 on 990223-0408.One Violation Occurred & Being Treated as non-cited Violation.Major Areas Inpsected:Operations,Engineering,Maint & Plant Support IR 05000263/19990101999-04-0909 April 1999 Insp Rept 50-263/99-10 on 990308-12.No Violations Noted. Major Areas Inspected:Review of Training Administrative Procedures & Operating Exam Matls & Observation & Evaluation of Licensed Operators IR 05000263/19990011999-03-11011 March 1999 Insp Rept 50-263/99-01 on 990112-0222.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000263/19980181999-01-20020 January 1999 Insp Rept 50-263/98-18 on 981201-990111.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19980191998-12-30030 December 1998 Insp Rept 50-263/98-19 on 981214-18.No Violations Noted. Major Areas Inspected:Review of Various Aspects of Licensees Chemistry & Radiation Protection Programs,Specifically REMP, PASS & Chemistry QC & Matl Condition IR 05000263/19980161998-12-14014 December 1998 Insp Rept 50-263/98-16 on 981014-1130.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support Re Performance of Emergency Preparedness Drill IR 05000263/19980171998-11-24024 November 1998 Insp Rept 50-263/98-17 on 981026-30.No Violations Noted. Major Areas Inspected:Physical Security Program IR 05000263/19980151998-11-10010 November 1998 Insp Rept 50-263/98-15 on 980821-1014.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000263/19980121998-09-18018 September 1998 Insp Rept 50-263/98-12 on 980719-0831.No Violations Noted. Major Areas Inspected:Opertions,Maint,Engineering & Plant Support IR 05000263/19980131998-09-11011 September 1998 Insp Rept 50-263/98-13 on 980810-13.No Violations Noted. Major Areas Inspected:Licensee Implementation of 10CFR50.65, Requirements for Monitoring Effectiveness of Maint at Nuclear Power Plants IR 05000263/19980141998-09-0404 September 1998 Insp Rept 50-263/98-14 on 980810-14.No Violations Noted. Major Areas Inspected:Licensee Liquid & Gaseous Effluents Program,Calibration & Testing of Area & Process Radiation Monitors & Free Release Program IR 05000263/19980111998-08-21021 August 1998 Insp Rept 50-263/98-11 on 980528-0718.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19980091998-07-30030 July 1998 Insp Rept 50-263/98-09 on 980511-0612.No Violations Noted. Major Areas Inspected:Review of 10CFR50.59 Safety Evaluation & Screening Activities IR 05000263/19980071998-06-25025 June 1998 Insp Rept 50-263/98-07 on 980413-0527.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maint & Plant Support IR 05000263/19980101998-05-26026 May 1998 Insp Rept 50-263/98-10 on 980427-30.No Violations Noted. Major Areas Inspected:Plant Support IR 05000263/19980061998-05-11011 May 1998 Insp Rept 50-263/98-06 on 980323-0423.No Violations Noted. Major Areas Inspected:Maint IR 05000263/19980041998-05-0808 May 1998 Insp Rept 50-263/98-04 on 980224-0414.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000263/19980081998-04-30030 April 1998 Insp Rept 50-263/98-08 on 980406-09.No Violations Noted. Major Areas Inspected:Radiation Protection Activities During Refueling & Maint Outage ML20216B2871998-04-0303 April 1998 Insp Rept 50-263/98-05 on 980309-13.Violations Noted.Major Areas Inspected:Physical Security Program ML20217A6881998-03-18018 March 1998 Insp Rept 50-263/98-02 on 980113-0223.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20216C1671998-03-0606 March 1998 Insp Rept 50-263/98-03 on 980209-13.Violations Noted.Major Areas Inspected:Various Aspects of Licensee RP Program Including Radwaste Processing,Packaging,Transportation & Implementation of Recent Changes to NRC & DOT Regulations IR 05000263/19970181998-02-0404 February 1998 Insp Rept 50-263/97-18 on 971125-980112.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20198G3171998-01-0606 January 1998 Page 6 of Plant Emergency Preparedness Exercise Insp Rept 50-263/97-16.Page Inadvertently Omitted W/Rept Transmitted by IR 05000263/19970161997-12-22022 December 1997 Insp Rept 50-263/97-16 on 971118-21.No Violations Noted. Major Areas Inspected:Evaluation of Performance During Plant Biennial Exercise of Emergency Plan by Regional EP Inspectors & Resident Inspector Staff from Plants ML20197B1731997-12-18018 December 1997 Insp Rept 50-263/97-15 on 971014-1124.Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000263/19970171997-12-15015 December 1997 Insp Rept 50-263/97-17 on 971118-21.No Violations Noted. Major Areas Inspected:General Radiation Protection Practices,Respiratory Protection Program & Radwaste Processing,Storage & Monitoring IR 05000263/19970141997-11-13013 November 1997 Insp Rept 50-263/97-14 on 970830-1013.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support.Rept Also Includes Insp follow-up of Security Related Issue by Regional Inspector IR 05000263/19970121997-09-18018 September 1997 Insp Rept 50-263/97-12 on 970708-0829.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19970111997-08-19019 August 1997 Insp Rept 50-263/97-11 on 970707-10.No Violations Noted. Major Areas Inspected:Installation of Emergency Core Cooling Sys Suction Strainers & pressure-suppression Chamber Coating Program IR 05000263/19970131997-08-14014 August 1997 Forwards Partially Withheld Insp Rept 50-263/97-13 on 970714-18 (Ref 10CFR73.21) IR 05000263/19970101997-07-23023 July 1997 Insp Rept 50-263/97-10 on 970623-27.No Violations Noted. Major Areas Inspected:Review of Issues Surrounding Licensee Discovery of Error in Head Loss Across ECCS Suction Strainers ML20149H9291997-07-17017 July 1997 Insp Rept 50-263/97-08 on 970528-0707.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19970091997-07-15015 July 1997 Insp Rept 50-263/97-09 on 970616-20.No Violations Noted. Major Areas Inspected:Licensees Chemistry & Radiation Protection Programs ML20141E8031997-06-18018 June 1997 Insp Rept 50-263/97-06 on 970412-0527.Violation Noted.Major Areas Inspected:Operations,Engineering,Maint & Plant Support IR 05000263/19970031997-05-0909 May 1997 Insp Rept 50-263/97-03 on 970220-0411.No Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000263/19970041997-04-14014 April 1997 Insp Rept 50-263/97-04 on 970310-14.No Violations Noted. Major Areas Inspected:Review of Training Administrative Procedures,Operating Exam Matl,Observation & Operating Exam, & Assessment of Simulator Fidelity ML20137K1881997-03-24024 March 1997 Corrected Pages 23,39,50 & 51 to Insp Rept 50-263/96-09,in Order to Correct Errors in Rept ML20137A1681997-03-11011 March 1997 Insp Rept 50-263/97-02 on 970109-0219.Violations Noted.Major Areas Inspected:Operations,Maint & Engineering ML20138N6991997-02-20020 February 1997 Insp Rept 50-263/96-09 on 961118-970108.Violations Noted. Major Areas Inspected:Maintenance,Engineering & Operations IR 05000263/19960121997-01-31031 January 1997 Insp Rept 50-263/96-12 on 961128-970108.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support ML20134G1611997-01-29029 January 1997 Insp Rept 50-263/96-11 on 961017-1127.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20133C4081996-12-27027 December 1996 Insp Rept 50-263/96-08 on 960829-1016.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000263/19960101996-11-0101 November 1996 Insp Rept 50-263/96-10 on 961028-1101.No Violations Noted. Major Areas Inspected:Status of Radiation Protection & Chemistry Controls IR 05000263/19960071996-10-0707 October 1996 Insp Rept 50-263/96-07 on 960721-0828.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20058H4431993-12-0606 December 1993 Rept 50-263/93-20 on 931202.Areas Discussed:Review of Circumstances Surrounding & Corrective Actions in Response to Licensee Identified Incident of Inadequate Storage & Marking of Safeguards Info at Plant 1999-09-01 Category:INSPECTION REPORT MONTHYEARIR 05000263/19990061999-10-21021 October 1999
[Table view]Insp Rept 50-263/99-06 on 990813-0923.Non-cited Violations Noted.Major Areas Inspected:Operations,Engineering, Maintenance & Plant Support IR 05000263/19990121999-10-13013 October 1999 Insp Rept 50-263/99-12 on 990913-17.No Violations Noted. Major Areas Inspected:Various Aspects of RP Program Including Radioactive Waste Processing,Storage,Packaging & Transportation & General RP Practices IR 05000263/19990051999-09-0101 September 1999 Insp Rept 50-263/99-05 on 990702-0812.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering, Maint & Plant Support IR 05000263/19990041999-07-28028 July 1999 Insp Rept 50-263/99-04 on 990521-0701.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19990111999-07-14014 July 1999 Insp Rept 50-263/99-11 on 990621-24.No Violations Noted. Major Areas Inspected:Licensee Performance During Exercise of Emergency Plan IR 05000263/19990021999-05-0303 May 1999 Insp Rept 50-263/99-02 on 990223-0408.One Violation Occurred & Being Treated as non-cited Violation.Major Areas Inpsected:Operations,Engineering,Maint & Plant Support IR 05000263/19990101999-04-0909 April 1999 Insp Rept 50-263/99-10 on 990308-12.No Violations Noted. Major Areas Inspected:Review of Training Administrative Procedures & Operating Exam Matls & Observation & Evaluation of Licensed Operators IR 05000263/19990011999-03-11011 March 1999 Insp Rept 50-263/99-01 on 990112-0222.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000263/19980181999-01-20020 January 1999 Insp Rept 50-263/98-18 on 981201-990111.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19980191998-12-30030 December 1998 Insp Rept 50-263/98-19 on 981214-18.No Violations Noted. Major Areas Inspected:Review of Various Aspects of Licensees Chemistry & Radiation Protection Programs,Specifically REMP, PASS & Chemistry QC & Matl Condition IR 05000263/19980161998-12-14014 December 1998 Insp Rept 50-263/98-16 on 981014-1130.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support Re Performance of Emergency Preparedness Drill IR 05000263/19980171998-11-24024 November 1998 Insp Rept 50-263/98-17 on 981026-30.No Violations Noted. Major Areas Inspected:Physical Security Program IR 05000263/19980151998-11-10010 November 1998 Insp Rept 50-263/98-15 on 980821-1014.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000263/19980121998-09-18018 September 1998 Insp Rept 50-263/98-12 on 980719-0831.No Violations Noted. Major Areas Inspected:Opertions,Maint,Engineering & Plant Support IR 05000263/19980131998-09-11011 September 1998 Insp Rept 50-263/98-13 on 980810-13.No Violations Noted. Major Areas Inspected:Licensee Implementation of 10CFR50.65, Requirements for Monitoring Effectiveness of Maint at Nuclear Power Plants IR 05000263/19980141998-09-0404 September 1998 Insp Rept 50-263/98-14 on 980810-14.No Violations Noted. Major Areas Inspected:Licensee Liquid & Gaseous Effluents Program,Calibration & Testing of Area & Process Radiation Monitors & Free Release Program IR 05000263/19980111998-08-21021 August 1998 Insp Rept 50-263/98-11 on 980528-0718.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19980091998-07-30030 July 1998 Insp Rept 50-263/98-09 on 980511-0612.No Violations Noted. Major Areas Inspected:Review of 10CFR50.59 Safety Evaluation & Screening Activities IR 05000263/19980071998-06-25025 June 1998 Insp Rept 50-263/98-07 on 980413-0527.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maint & Plant Support IR 05000263/19980101998-05-26026 May 1998 Insp Rept 50-263/98-10 on 980427-30.No Violations Noted. Major Areas Inspected:Plant Support IR 05000263/19980061998-05-11011 May 1998 Insp Rept 50-263/98-06 on 980323-0423.No Violations Noted. Major Areas Inspected:Maint IR 05000263/19980041998-05-0808 May 1998 Insp Rept 50-263/98-04 on 980224-0414.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000263/19980081998-04-30030 April 1998 Insp Rept 50-263/98-08 on 980406-09.No Violations Noted. Major Areas Inspected:Radiation Protection Activities During Refueling & Maint Outage ML20216B2871998-04-0303 April 1998 Insp Rept 50-263/98-05 on 980309-13.Violations Noted.Major Areas Inspected:Physical Security Program ML20217A6881998-03-18018 March 1998 Insp Rept 50-263/98-02 on 980113-0223.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20216C1671998-03-0606 March 1998 Insp Rept 50-263/98-03 on 980209-13.Violations Noted.Major Areas Inspected:Various Aspects of Licensee RP Program Including Radwaste Processing,Packaging,Transportation & Implementation of Recent Changes to NRC & DOT Regulations IR 05000263/19970181998-02-0404 February 1998 Insp Rept 50-263/97-18 on 971125-980112.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20198G3171998-01-0606 January 1998 Page 6 of Plant Emergency Preparedness Exercise Insp Rept 50-263/97-16.Page Inadvertently Omitted W/Rept Transmitted by IR 05000263/19970161997-12-22022 December 1997 Insp Rept 50-263/97-16 on 971118-21.No Violations Noted. Major Areas Inspected:Evaluation of Performance During Plant Biennial Exercise of Emergency Plan by Regional EP Inspectors & Resident Inspector Staff from Plants ML20197B1731997-12-18018 December 1997 Insp Rept 50-263/97-15 on 971014-1124.Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000263/19970171997-12-15015 December 1997 Insp Rept 50-263/97-17 on 971118-21.No Violations Noted. Major Areas Inspected:General Radiation Protection Practices,Respiratory Protection Program & Radwaste Processing,Storage & Monitoring IR 05000263/19970141997-11-13013 November 1997 Insp Rept 50-263/97-14 on 970830-1013.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support.Rept Also Includes Insp follow-up of Security Related Issue by Regional Inspector IR 05000263/19970121997-09-18018 September 1997 Insp Rept 50-263/97-12 on 970708-0829.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19970111997-08-19019 August 1997 Insp Rept 50-263/97-11 on 970707-10.No Violations Noted. Major Areas Inspected:Installation of Emergency Core Cooling Sys Suction Strainers & pressure-suppression Chamber Coating Program IR 05000263/19970131997-08-14014 August 1997 Forwards Partially Withheld Insp Rept 50-263/97-13 on 970714-18 (Ref 10CFR73.21) IR 05000263/19970101997-07-23023 July 1997 Insp Rept 50-263/97-10 on 970623-27.No Violations Noted. Major Areas Inspected:Review of Issues Surrounding Licensee Discovery of Error in Head Loss Across ECCS Suction Strainers ML20149H9291997-07-17017 July 1997 Insp Rept 50-263/97-08 on 970528-0707.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19970091997-07-15015 July 1997 Insp Rept 50-263/97-09 on 970616-20.No Violations Noted. Major Areas Inspected:Licensees Chemistry & Radiation Protection Programs ML20141E8031997-06-18018 June 1997 Insp Rept 50-263/97-06 on 970412-0527.Violation Noted.Major Areas Inspected:Operations,Engineering,Maint & Plant Support IR 05000263/19970031997-05-0909 May 1997 Insp Rept 50-263/97-03 on 970220-0411.No Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000263/19970041997-04-14014 April 1997 Insp Rept 50-263/97-04 on 970310-14.No Violations Noted. Major Areas Inspected:Review of Training Administrative Procedures,Operating Exam Matl,Observation & Operating Exam, & Assessment of Simulator Fidelity ML20137K1881997-03-24024 March 1997 Corrected Pages 23,39,50 & 51 to Insp Rept 50-263/96-09,in Order to Correct Errors in Rept ML20137A1681997-03-11011 March 1997 Insp Rept 50-263/97-02 on 970109-0219.Violations Noted.Major Areas Inspected:Operations,Maint & Engineering ML20138N6991997-02-20020 February 1997 Insp Rept 50-263/96-09 on 961118-970108.Violations Noted. Major Areas Inspected:Maintenance,Engineering & Operations IR 05000263/19960121997-01-31031 January 1997 Insp Rept 50-263/96-12 on 961128-970108.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support ML20134G1611997-01-29029 January 1997 Insp Rept 50-263/96-11 on 961017-1127.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20133C4081996-12-27027 December 1996 Insp Rept 50-263/96-08 on 960829-1016.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000263/19960101996-11-0101 November 1996 Insp Rept 50-263/96-10 on 961028-1101.No Violations Noted. Major Areas Inspected:Status of Radiation Protection & Chemistry Controls IR 05000263/19960071996-10-0707 October 1996 Insp Rept 50-263/96-07 on 960721-0828.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20058H4431993-12-0606 December 1993 Rept 50-263/93-20 on 931202.Areas Discussed:Review of Circumstances Surrounding & Corrective Actions in Response to Licensee Identified Incident of Inadequate Storage & Marking of Safeguards Info at Plant 1999-09-01 Category:UTILITY MONTHYEARIR 05000263/19900131990-07-18018 July 1990
[Table view]Partially Withheld Safeguards Insp Rept 50-263/90-13 on 900604-08,0611-12 & 0711.Major Areas Inspected:Physical Security Insp Involving,Mgt Support,Security Program Plans, Protected & Vital Area Physical Barriers IR 05000263/19890131989-06-0101 June 1989 Enforcement Conference Rept 50-263/89-13 on 890427.Major Areas Discussed:Apparent Violations of 10CFR50,App B, Criterion Xvi Re Inadequate Licensee Corrective Actions for 10CFR50.49 Environ Qualification Deficiencies ML20247N8711989-05-26026 May 1989 Insp Rept 50-263/89-14 on 890512.Violations Noted.Major Areas Inspected:Violation Re RCIC Being Made Inoperable Due to RCIC Steamline Flooding,Circumstances Surrounding Event & Corrective Actions in Response to Event IR 05000263/19890081989-04-10010 April 1989 Partially Withheld Physical Security Insp Rept 50-263/89-08 on 890227-0303 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Mgt Support,Security Program Plans,Audits, Protected & Vital Area Barriers & Vital Access Controls IR 05000263/19880181988-11-10010 November 1988 Partially Withheld Reactive Physical Security Insp Rept 50-263/88-18 (Ref 10CFR73.21).Violations Noted:Failure to Maintain Adequate Response Force & Effective Vital Area Portal & to Implement Compensatory Measures IR 05000263/19882001988-11-0808 November 1988 Insp Rept 50-263/88-200 on 880711-22.Deviations Noted. Major Areas Inspected:Program for Implementing Emergency Operating Procedures,Per NUREG-0737,Suppl 1 IR 05000263/19870081987-06-0808 June 1987 Mgt Meeting Repts 50-263/87-08,50-282/87-10 & 50-306/87-10 on 870526.Areas Discussed:Operator Licensing Program Implementation & Methods to Improve Performance in Operator Licensing IR 05000263/19870031987-03-11011 March 1987 Insp Rept 50-263/87-03 on 870123-0213.Violation Noted: Inadequate Procedure Used During Preventive Maint IR 05000263/19870021987-02-17017 February 1987 Insp Rept 50-263/87-02 on 861104-870204.No Violations Noted. Major Areas Inspected:Operational Safety Verification,Maint, Surveillance,Security,Radiation Protection,Spent Fuel Shipment,Bulletin & Regional Requests IR 05000263/19860091986-11-26026 November 1986 Partially Withheld Spent Fuel Physical Security Insp Rept 50-263/86-09 on 861113-14 (Ref 10CFR73.21).No Noncompliance Noted.Major Areas Inspected:Spent Reactor Fuel Physical Protection Requirements & Shipping Activities IR 05000263/19850241986-02-0404 February 1986 Insp Rept 50-263/85-24 on 851126-860120.No Violation or Safety Concerns Noted.Major Areas Inspected:Operational Safety verification,maint,surveillance,NUREG-0737 TMI Items, LER Repts & IE Bulletins IR 05000263/19850251985-12-27027 December 1985 Insp Rept 50-263/85-25 on 851223.Violation Noted:Failure to Determine as-found Containment Leakage IR 05000263/19850231985-12-0505 December 1985 Insp Rept 50-263/85-23 on 850910-1125.No Violation Noted. Major Areas Inspected:Previous Insp Findings,Operational Safety Verification,Spent Fuel Shipments,Lers & IE Bulletins IR 05000263/19850091985-10-28028 October 1985 Insp Rept 50-263/85-09 on 851008-11.No Violation,Deficiency or Deviation Noted.Major Areas Inspected:Emergency Preparedness Exercise,Including Observations of Key Functions & Locations During Exercise IR 05000263/19850171985-06-12012 June 1985 Insp Rept 50-263/85-17 on 850528-31.No Noncompliance Noted. Major Areas Inspected:Security Plan & Implementing Procedures,Mgt Effectiveness,Security Organization & Records.Details Withheld (Ref 10CFR73.21) IR 05000263/19820071982-07-20020 July 1982 Corrected Page 3 of IE Insp Rept 50-263/82-07.Sentence Four of Second Paragraph in Section 4 Amended IR 05000263/19820011982-07-15015 July 1982 IE Insp Rept 50-263/82-01 on 820301-0430.Noncompliance Noted:Three safety-related Work Request Authorizations Did Not Contain Required Info Per ANSI Std N18.7-1976 & RHR Suction Inboard Valve Removed from Svc on 820408 IR 05000263/19820031982-07-0909 July 1982 IE Insp Rept 50-263/82-03 on 820503-28.Noncompliance Noted: Failure to Notify NRC Operations Ctr of Accidental Radioactive Release within 1-h IR 05000263/19820061982-06-0707 June 1982 IE Insp Rept 50-263/82-06 on 820601-04.No Noncompliance Noted.Major Areas Inspected:Effluent Control Instrumentation,Testing of Air Cleaning Sys & Reactor Coolant Water Quality 1990-07-18 Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS MONTHYEARIR 05000263/19990061999-10-21021 October 1999
[Table view]Insp Rept 50-263/99-06 on 990813-0923.Non-cited Violations Noted.Major Areas Inspected:Operations,Engineering, Maintenance & Plant Support IR 05000263/19990121999-10-13013 October 1999 Insp Rept 50-263/99-12 on 990913-17.No Violations Noted. Major Areas Inspected:Various Aspects of RP Program Including Radioactive Waste Processing,Storage,Packaging & Transportation & General RP Practices IR 05000263/19993011999-09-27027 September 1999 NRC Operator Licensing Exam Rept 50-263/99-301(including Completed & Graded Tests) for Tests Administered on 990823-26.Both Applicants Passed All Sections of Exam IR 05000263/19990051999-09-0101 September 1999 Insp Rept 50-263/99-05 on 990702-0812.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering, Maint & Plant Support IR 05000263/19990041999-07-28028 July 1999 Insp Rept 50-263/99-04 on 990521-0701.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19990111999-07-14014 July 1999 Insp Rept 50-263/99-11 on 990621-24.No Violations Noted. Major Areas Inspected:Licensee Performance During Exercise of Emergency Plan IR 05000263/19990021999-05-0303 May 1999 Insp Rept 50-263/99-02 on 990223-0408.One Violation Occurred & Being Treated as non-cited Violation.Major Areas Inpsected:Operations,Engineering,Maint & Plant Support IR 05000263/19990101999-04-0909 April 1999 Insp Rept 50-263/99-10 on 990308-12.No Violations Noted. Major Areas Inspected:Review of Training Administrative Procedures & Operating Exam Matls & Observation & Evaluation of Licensed Operators IR 05000263/19990011999-03-11011 March 1999 Insp Rept 50-263/99-01 on 990112-0222.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000263/19980181999-01-20020 January 1999 Insp Rept 50-263/98-18 on 981201-990111.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19980191998-12-30030 December 1998 Insp Rept 50-263/98-19 on 981214-18.No Violations Noted. Major Areas Inspected:Review of Various Aspects of Licensees Chemistry & Radiation Protection Programs,Specifically REMP, PASS & Chemistry QC & Matl Condition IR 05000263/19980161998-12-14014 December 1998 Insp Rept 50-263/98-16 on 981014-1130.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support Re Performance of Emergency Preparedness Drill ML20198B7851998-12-14014 December 1998 Notice of Violation from Insp on 981014-1130.Violation Noted:As of 981113,several Fire Brigade Personnel Not Listed as Qualified Fire Brigade Members Had Not Participated in Required Number of Fire Brigade Drills IR 05000263/19980171998-11-24024 November 1998 Insp Rept 50-263/98-17 on 981026-30.No Violations Noted. Major Areas Inspected:Physical Security Program IR 05000263/19980151998-11-10010 November 1998 Insp Rept 50-263/98-15 on 980821-1014.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000263/19980121998-09-18018 September 1998 Insp Rept 50-263/98-12 on 980719-0831.No Violations Noted. Major Areas Inspected:Opertions,Maint,Engineering & Plant Support IR 05000263/19980131998-09-11011 September 1998 Insp Rept 50-263/98-13 on 980810-13.No Violations Noted. Major Areas Inspected:Licensee Implementation of 10CFR50.65, Requirements for Monitoring Effectiveness of Maint at Nuclear Power Plants IR 05000263/19980141998-09-0404 September 1998 Insp Rept 50-263/98-14 on 980810-14.No Violations Noted. Major Areas Inspected:Licensee Liquid & Gaseous Effluents Program,Calibration & Testing of Area & Process Radiation Monitors & Free Release Program IR 05000263/19980991998-08-26026 August 1998 SALP Rept 50-263/98-99 for Monticello Nuclear Generating Plant,Covering Period from 960721-980718 IR 05000263/19980111998-08-21021 August 1998 Insp Rept 50-263/98-11 on 980528-0718.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19980091998-07-30030 July 1998 Insp Rept 50-263/98-09 on 980511-0612.No Violations Noted. Major Areas Inspected:Review of 10CFR50.59 Safety Evaluation & Screening Activities IR 05000263/19980071998-06-25025 June 1998 Insp Rept 50-263/98-07 on 980413-0527.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maint & Plant Support IR 05000263/19980101998-05-26026 May 1998 Insp Rept 50-263/98-10 on 980427-30.No Violations Noted. Major Areas Inspected:Plant Support IR 05000263/19980061998-05-11011 May 1998 Insp Rept 50-263/98-06 on 980323-0423.No Violations Noted. Major Areas Inspected:Maint IR 05000263/19980041998-05-0808 May 1998 Insp Rept 50-263/98-04 on 980224-0414.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000263/19980081998-04-30030 April 1998 Insp Rept 50-263/98-08 on 980406-09.No Violations Noted. Major Areas Inspected:Radiation Protection Activities During Refueling & Maint Outage ML20247M5311998-04-13013 April 1998 EN-98-026:on 980420,informs Commission That NRC Will Exercise Enforcement Discretion Per Section VII.B.6 of Enforcement Policy & Not Issue NOV or Propose Civil Penalty to Northern States Power Co for Two Violations W/Rhr ML20216B2871998-04-0303 April 1998 Insp Rept 50-263/98-05 on 980309-13.Violations Noted.Major Areas Inspected:Physical Security Program ML20217A6881998-03-18018 March 1998 Insp Rept 50-263/98-02 on 980113-0223.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20217A6751998-03-18018 March 1998 Notice of Violation from Insp on 980113-0223.Violation Noted:Inspectors Identified That Shift Supervisor Failed to Remove hold-and-secure Card Attached to Control Room hand- Switch for Number 13 ML20216C1521998-03-0606 March 1998 Notice of Violation from Insp on 980209-13.Violation Noted: on 971028,licensee Did Not Make Surveys to Assure Compliance w/10CFR20.1201(a),which Limits Occupational Radiation Exposure ML20216C1671998-03-0606 March 1998 Insp Rept 50-263/98-03 on 980209-13.Violations Noted.Major Areas Inspected:Various Aspects of Licensee RP Program Including Radwaste Processing,Packaging,Transportation & Implementation of Recent Changes to NRC & DOT Regulations IR 05000263/19970181998-02-0404 February 1998 Insp Rept 50-263/97-18 on 971125-980112.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20198G3171998-01-0606 January 1998 Page 6 of Plant Emergency Preparedness Exercise Insp Rept 50-263/97-16.Page Inadvertently Omitted W/Rept Transmitted by IR 05000263/19970161997-12-22022 December 1997 Insp Rept 50-263/97-16 on 971118-21.No Violations Noted. Major Areas Inspected:Evaluation of Performance During Plant Biennial Exercise of Emergency Plan by Regional EP Inspectors & Resident Inspector Staff from Plants ML20197B1731997-12-18018 December 1997 Insp Rept 50-263/97-15 on 971014-1124.Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 07100014/20110241997-12-18018 December 1997 Notice of Violation from Insp on 971014-1124.Violation Noted:Activities Affecting Quality Were Not Accomplished in Accordance W/Documented Procedures IR 05000263/19970171997-12-15015 December 1997 Insp Rept 50-263/97-17 on 971118-21.No Violations Noted. Major Areas Inspected:General Radiation Protection Practices,Respiratory Protection Program & Radwaste Processing,Storage & Monitoring ML20199E5871997-11-13013 November 1997 Notice of Violation from Insp on 970830-1013.Violation Noted:From 960229-970410,northwest Corner of Established Vehicle Barrier Sys Not Adequate to Protect Against Use of Land Vehicle in That Barrier Not Continuous IR 05000263/19970141997-11-13013 November 1997 Insp Rept 50-263/97-14 on 970830-1013.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support.Rept Also Includes Insp follow-up of Security Related Issue by Regional Inspector IR 05000263/19970121997-09-18018 September 1997 Insp Rept 50-263/97-12 on 970708-0829.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19970111997-08-19019 August 1997 Insp Rept 50-263/97-11 on 970707-10.No Violations Noted. Major Areas Inspected:Installation of Emergency Core Cooling Sys Suction Strainers & pressure-suppression Chamber Coating Program IR 05000263/19970131997-08-14014 August 1997 Forwards Partially Withheld Insp Rept 50-263/97-13 on 970714-18 (Ref 10CFR73.21) IR 05000263/19970101997-07-23023 July 1997 Insp Rept 50-263/97-10 on 970623-27.No Violations Noted. Major Areas Inspected:Review of Issues Surrounding Licensee Discovery of Error in Head Loss Across ECCS Suction Strainers ML20149H9291997-07-17017 July 1997 Insp Rept 50-263/97-08 on 970528-0707.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support ML20149H9221997-07-17017 July 1997 Notice of Violation from Insp on 970528-0707.Violation Noted:Reactor Bldg Closed Cooling Water Valve 2-2 & Associated Piping Removed from Pump,However,Safety Tag on Valve Had Not Been Properly Released IR 05000263/19970091997-07-15015 July 1997 Insp Rept 50-263/97-09 on 970616-20.No Violations Noted. Major Areas Inspected:Licensees Chemistry & Radiation Protection Programs ML20141E8031997-06-18018 June 1997 Insp Rept 50-263/97-06 on 970412-0527.Violation Noted.Major Areas Inspected:Operations,Engineering,Maint & Plant Support ML20141E7961997-06-18018 June 1997 Notice of Violation from Insp on 970412-0527.Violation Noted:Inspectors Identified That Operations Personnel Did Not Know That Number 13 ESW Pump Had Been Operating for 2 Days Following 970408 Loss of Power to Number 15 4160 Volt PNO-III-97-046, on 970516,WI Energy Co & Northern States Power Co Announced They Were Terminating Plans for Proposed Merger of Two Companies Into New Co,Primergy Corp.Utils Attributed Decision to Changing Regulatory Policies1997-05-16016 May 1997 PNO-III-97-046:on 970516,WI Energy Co & Northern States Power Co Announced They Were Terminating Plans for Proposed Merger of Two Companies Into New Co,Primergy Corp.Utils Attributed Decision to Changing Regulatory Policies 1999-09-27 |
Inspection Report - Monticello - 1990013 | |
---|---|
Assessments
|
Text
'
- f yp .L +>
. * * ,e
'
U, S. NUCLEAR REGULATORY COMMISSION
REGION III
feport l No, _ 50-263/90013(DRSS)
Docket No. 50-263 License No. DPR-22 Licensee: Northern States Power Company 414 Nicollet Mall Minneapolis, MN 55401 Facility Name: Monticello Nuclear Generating Station Inspection At: Monticello Site, Monticello, Minnesota Inspection Dates: June 4-8, 1990 onsite June 11-12, and July 11, 1990 in Region III office Inspector: 91d - M 4 b -
PIM O Date Signed T _ J. Madeda Physical Security Inspector Approved By: ,
W 7//8/96 fames R Creed, Chief Date Signed Safeguards Section Inspection Summary Inspection on June 4 - July 11,1990 (Report No. 50-263/90013(DRSS)) '
Areas Inspected: Routine, unannounced physical security inspection involving:
Management Support, Security Program Plans, and Audits; Protected and Vital Area Physical Barriers, Detection and Assessment Aids; Protected and Vital
~ Area Access Control-of Personnel, Packages, and Vehicles; Alarm Stations and Communications; Power Supply; Testing, Maintenance and Compensatory Measures; Security-Training and Qualification; Security Plan and Implementing Procedures; Personnel Training and Qualifications; Contingency Plan; Safeguards Information and a review of a previous inspection findin Results: Based on the results of this inspection, we have generally concluded that the reviewed portions of the licensee's physical security program _
demonstrated.the below listed findings as noted in the appropriate portions
'of the report detail One finding concerning the licensee's practice of not testing tamper alarm components when returned to service u s identifie (Section 5.a)
. 0ne' finding in the licensee's intrusion-detection system relating to rendering some components inoperative was ~ identified. (Section 5.b)
Enclosure Contains 9007230170 900718 ,
PDR ADOCK 05000263pdc .o Upon Separation Thi Page is Decontrolled
.
"
.. .............i.. .i..imin i