- ums EP-205 g .,_ , . --
.. ,,,, ; Paga 1
. u ;,
- --- Rev. 1 WJK
- lhd f
- }{ Q (/. 8T13@ . Ah PHILADELPHIA ELECTRIC COMPANY PEACH BOTTOM UNITS 2 AND 3 EMERGENCY PLAN IMPLEMENTING PROCEDURE EP-205 RADIATION PROTECTION TEAM ACTIVATION PURPOSE .
To define the actions required to activate the Radiation Protection Team.
REFERENCES
- 1. Peach Bottom Atomic Power Station Emergency Plan Section Title 5.2.2.2.1 Organizational Control of Emergencies 6.0 , Emergency Measures
- 2. NUREG 0654 Criteria for Preparation and Evaluation
'6f Radiological Emergency Rasponse Plans and Preparedness in Support of Nuclear Power Plants.
APPENDIX EP-205-1 Contacting Radiation Management Corporation EP-205-2 Emergency Exposure Limits (Emergency Plan Table 6.1) l ACTIOt! LEVELS d e Radiation Protection Team or its subgroups shall be activated by the Emergency Director if and when he needs their assistance, regardless of the class of emergency.
1 1
l l
l 8202030076 820128 -
PDRADOCK05000g F
EP-205 Pega 2 Rev. 1 WJK:lhd l
I
/2CCAUTIONS . l
- 1. Team member's exposure should be limited to the I administrative guide levels in Appendix EP 205-2, '
Imergency Exposure Limits. l
- 2. Vehicles requiring decontamination should be .
decontaminated at any of the following assembly areas:
North Sub Station President's Utility Building (PUB) ,
Delta Service Building IMMEDIATE ACTIONS 1.0 Emergency Director shall:
1.1 Direct the Operations HP to assume the role of Interim Radiation Protection Team Laader to:
- 1. Form a Team.
- 2. Initiate surveys & sampling appropriate to the event.
l l 3. Call the Radiation Protection Team Leader. If l the situation permits, discuss the problem with the Radiation Protection Team Leader so he can assess the I
situation and determine how many team members will be necessary for anticipated operations.
2.0 Operations HP shall:
2.1 Upon request of the Emergency Director, assume the role of Radiation Protection Team Leader.
l 2.2 Form a team from qualified people. Obtain five two way radios from the Shif t Superintendeht's Office. Have the team report to the Operations Support Center or a location l designated by the Emergency Director.
l l
l l
I l
l
l
. . O EP-205 Page 3 Rev. 1 WJK:lhd '
2.3 Assign the assembled personnel to function on the following interim groups as necessary to provide support to the Emergency Director:
p Sub Grou's Radiation Prote$ tion Team Group activation should be implemented in accordance with:
Chem. Sampling and Ana- EP 205A lysis Group Radiation Survey Group EP 205B a) Plant Surveys b) Field Surveys. ,
Dosimetry, Bioassay and EP 205C l Respiratory Protection l Dose Assessment EP 316 3.0 Radiation Protection Team Members shall:
3.1 One team member obtain 5 two way radios from the Shift Superintendent's Office. ,
3.2 Report to the Operations Support Center, or the location specified by Emergency Director.
FOLLOW-UP ACTIONS 1.0 Radiation Protection Team Leader shall:
( 1.1 Direct team members to assemble the equipment that will be needed to perform anticipated tasks (surveys, calculations, etc.).
2.0 Radiation Protection Team Members shall:
2.1 Obtain emergency equipment stored in the Operations '
Support Center. .
2.2 verify operability of the emergency equipment assembled in the Operations Support Center.
2.3 Standby and await instructions from the Radiation Protection Team Leader.
EP-205 PEgo 4
. Rev. 1 WJK:1hd '
3.0 Radiation Protection Team Leader shall: (if requested by Emerg. Director) 3.1 Report to the Interim Radiation Protection Team Leader, obtain a staths report, and relieve him. r .
3.2 Assign team members to 'the Radiation Protection Team subgroups, as necessary.
3.3 Prepare Appendix EP-205-1, Contacting Radiation Management Corporation, when requested by the Site Emergency Coordinator.
i l
S 9
l 1 t
l
)
- l. .
EP-205 .
Pcgo 5 Rev. 1 WJK:lhd '
Appendix EP-205-1 CONTACTING RADIATION MANAGEMENT CORPORATION r
Phone Number - 215-243-2990 This is (Name) repr'esenting the Radiation' Protection Team of the Peach Bottom Atomic Power Station.
There has been a release of radioactive material from the Unit (2), (3) plant and your assistance is required in the following areas:
Radiation Surveys ( Low Level, High Level) ,
i' BETA ;
GAMMA :
NEUTRON :
Decontamination ( ALPHA, BETA, GAMMA)
Environmental sample analysis .
Air particulate samples collection / evaluation -
Bioassay ,
Wholebody counting Other (specify below)
Approach the site from (direction, route, etc.).
Respiratory protection (is/is not) rsecessary.
Anti-contamination clothing requirements are:
full parital (booties, gloves, other) 5 a<iditional Comments:
9 i
mum !
- P ga 6 Rev. 1 WJK:lhd Appendix EP-205-2 2
EMERGENCY EXPOSURE LIMITS l Projected j . Whole Body Thyroid '
Authorized
{ Fanction Dose Dose By
- 1. Life Saving and .. Emergency **.
Reduction of 75 rem
- 375 rem Director l Injury 1
- 2. Operation of Equipnent Emergency ** i to Mitigate an 25 rem
- 125 rem Director l Emergency )
- 5. Re-Entry / Recovery Administrative "dministrative A
Activities Guide Lines Guide Lines N/A
Reference:
EPA-520/1-75-001 Table 2.1
- Such exposure shall be on a voluntary basis -
e S
9 0
=
~~
, , s D EP-207C s
- - - Pr.ga 1 ,,
e c:. ~ n'.:D E * "~2' -
Rev. 0 -
l K f. ; ~ ~ ~ " '. '. _ WJK:ljm' ;
g Y. . k?Q PHILADELPHIA ELECTRIC COMPANY '5
. .c . -
0 ~5-.- - . .
PEACH BOTTOM UNITS 2 AND 3 s C~. f u e
- ' ~ ~ ~ ~ ~
EMERGENCY PLAN IMPLEMENTING PROCEDURE 7 s .
EP-207C FIRST AID . . . ,
lhF I
PURPOSE To define the actions of.the Personnel Safety Team First ,
Aid Group. ,
i REFERENCES -
d.
l
- 1. Peach Bottom Atomic Power Station Emergency Plan , j
. j.
Sectiorf Title ,
t 5.2.2.2.2 . . Personnel Safety Team ~ -
l 6.5.e Decont' amination and First Aid 7.5 First Aid and Medical Facilities ,
- 2. NUREG 0654 Cr$.teria for Preparation and Evaluation 3 of Radiological Emergency Response Plans i and Preparednes,s in Support af Nuclear Power Plants. ,
- 3. EP-311 Handling Personnel with Serious Injuries, Radio-active Contamination Exposure or Excessive Radiation Exposure, Emergency Director Functions.
APPEt! DIX CP-207C-1 Injured Personnel Report Form ACTICA L3 VEL
'Jne First Aid Group will be activated whenever' a personnel injury is classified as an Unusual Event.
PRSCAUTIONS
- 1. Life-saving first aid treatment has priority over decontamination or treatment for radiation exposure.
l l 2. Minimize radiation exposure and avoid group member contamination as much as practical.
4 l
l t
- t. .
.s
, gg N '
' i
' ~
' Page 2 Rev. 0 i
~
' *' WJK:ljm t .
- \
- 3. If'grcss evternal' contamination is found, interbal l*
scontaminat' ion should be suspected. .
4 s
- 4. Any material removed from a contaminated person shall r
't be-recovered,and used for isotopic analysis. ,
i
- 5. The First Aid Group Leader Will maintain s qQntact with I the Personnel Safety Team Leader. l
- 6. Objects causing contaminated wounds should be recover $c v i or smeared (or isotopic identificacior, if possible. s IMMEDIATE ACTIONS
) .
1.0 Personnel Safety Team Leader shall:
) 1.1 Assign members from the Personnel Safety Team to form '
First Aid Grono(s). At least on*2 member shall be Multi-media qualified-1.2 Appoint the most qualified person of the group to be the First Aid Group Leader and to carry out Section 2.0
) t of this procedure. ,
^
1.3 Obtain exposure limit from'the Emergency D$ rector for
) this activity. If subsequent first aid operations are '
~ nece1sary, the Emergency Director will adjust the radiation expouure bnit accordingly.
) '
1.LJ If'ontside medical help is necessary, request the Emergency-Director to contact the necessary help 'as
) i ' ' described in Section 4.0 of this procedure.
' ~
l.5 Arrange for inventory and restock the first aid kits, I if necessay.
'2.L First Aid Group Leader shall:
) '
,\
s 2.1 Determine the extent 'of ~the . injury' and direct; adminis-
~~
tration of first-aid. , i
) ,
g-
?.2 Report to tbe Personnel Safety Team Leader the extent of the individual's i~njuries and recommend supplementary
} medical, actions as necessary J.i.ev, hospital'ization).
x
) ,
)
EP-207C Paga 3 Rev. 0 ,
WJK:ljm 4
2.3 Direct the First Aid Group to transport the injured person to a Site First Aid Facility, if practicable.
Locations: ,
- 1. Radwaste Building,- elevaticn 135'
- 2. Outside the Security fence, along the fence.just ;
north of the circulation water pump house.
3.0 First Aid Group Members shall:
3.1 Administer first aid, as necessary.
o NOTE: If contamination is suspected, survey the injured area. If contamination is found, go to step 3.4 3 of this procedure.
3.2 Perform a radiation and contamination survey of the i
) person and subsequently the area.
~
3.3 Transport the injured person to a Si:e First Aid
) Facility if practicable.
3.4 Perform the following if c$ntamination is suspected
) on the injured person. , ,
3.4.1 Wear necessary anti-contamination clothing IF,
) PRACTICABLE.
NOTE: IF THE INJURY IS SEVERE, IMMEDIATE MEDICAL
) TREATMENT IS OF THE HIGHEST PRIORITY-AND RADIOLOGICAL. CONTROLS ARE SECONDARY.
) 3.4.2 Administer appropriate first aid, being careful to limit the spread of contamination and' limit' personal exposure. .
3.4.3 Prepare the person for transportation.by a covering the contaminated area with a protective
)- wrap. This may require covering the stretcher i and placing the person on the stretcher and wrapping ,
the cover around the person or wrapping the injury l 3 in protective wrap.- (Avoid excessive wrapping to preven dehydration of the person) . j 3 3.4.4 Transport the injured person to the Site First Aid l Facility for treatment by the Site Physician's l Assistant or local physician. l 1
]- l NOTE: If the injured. person is going to be transported to an offiste medical facility, 3 it may not be feasible to bring the person l
1
~. - -__________-a
umm ,
' ~
EP-207C Page 4 Rev. 0 ,
WJK:ljm .
to the First Aid Facility, instead move the person to a safe place which is easily accessible for the transfer to a vehicle.
3.5 Recover any contaminated articles of clothing that may have been removed from.the person for isotopic analysis.
4.0 Site Physician's Assistant or his designee"shall':
4.1 Provide guidance to the First Aid Group as much as practicable through the Personnel Safety Team Leader.
4.2 Prepare the First Aid Facility for receiving injured l personnel.
4.3 Under direction of the Emergency Director call the following offsite agencies for assistance, as necessary:
See EP 209, Appendix N for telephone numbers. .
' Ambulance Service:
Delta-Cardiff Fire and Ambulance Company ,
Hospital-Contaminated Injured Personnel:
Harford Memor,ial Hospital Hospital-Injured Personnel-No Contamin'ation
~
York Hospital or -
Harford Hospital . .
NOTE: When' contacting offsite agencies, give them ths
- following information.
a) Number of injured persons b) Estimated Time of Arrival (Hospi.tals only) c) Nature of trauma
)
)
)
b , . ._..... . __ _ . _ _ --. _ _ _ .
EP-207C Page 5 Rev. 0 ,
. WJK:ljm APPENDIX EP 207C-1 FIRST AID GROUP INJURY REPORT FORM l
(PREPARE IN DUPLICATE) .
Injured Person's Name ___
Age Harshaw Badge No. or '
! Social Security No. ,
( Male Female l <
Type and location of Injury l
1 t
- b i
Radioactive Contamination Yes No Level l
0 Location Radiation Exposure Estitaate __,
Where did injury. occur D
Prepared by First Aid Group Leader D Signature Group Members D ,
l D ~
D If practicable forward original, with the person, to the Site First Aid Facility or Hospital as appropriate.
O b
]
um b o 7" .. ; . _ - J.g. ._ EP-303
- 7 . .'.'" Page 1 <
-~~
Rev. 0 .
WJK:lhd
- 3/ ( Mhyp W"Vb
~ ~
PHILADELPHIA ELECTRIC COMPANY
~~-~~
PEACH BOTTOM UNITS 2 AND 3
. . . _____. EMERGENCY PLAN IMPLEMENTING PROCEDURE .
EP-303 PARTIAL PLANT EVACUATION --
- PURPOSE
- 1. To define the actions to be performed in the event that a plant evacuation is required due to unexpected or uncontrolled hazards in two or more large operating areas.
I
- 2. Assemble personnel for a possible site evacuation. !
REFERENCES
- 1. Peach Bottom Atomic Power Station Emergency Plan Section Title :
6.0 Emergency Measures
- 2. NUREG 0654 ' Criteria for Preparation and Evaluation i of Radiological Emergency Response Plans and Preparedness in Support of l
- Nuclear Power Plants.
- 3. EP 207A Search and Rescue t
l
- 4. EP 207B Personnel Asse2hly and Accountability
- 5. SP 207C First Aid G. 3? 207D Personnel Monitoring and Decontamination.
- 7. SP 301 Operating the Evacuation Alarm and Pond Page
! System .
- 3. E? 306 Evacuation o5 the'Information Center ACTIOJ LEVEL
- 1. Il <1n Unusual Event, or Alert requires evacuation of two o t- more large operating areas (reactor building, turbine building, radwaste building, rcombiner building) as indicated by:
- a. An increase in the area radiation monitors or continuous air monitor indications to greater than alarm levels.
~
- b. Radiation levels greater than 100mR/hr within those operating areas affected which normally experience less than 10 mR/hr.
O
> EP-303 Page 2 Rev. O j WJK:lhd i
-7
- c. Airborne radioactivity greater than 3 x 10 uCi/cc'for an
- unidentified isotope in an occupational environment, except for noble gas activity. .
NOTE: Exposure to noble gases shall be controlled based on radiation exposure (mR/hr).
- d. Release, leakage, or spill of a toxic reagent such that the concentration of chemical vapors makes the areas uninhabitable.
- 2. Unusual Event or Alert caused by unexplained radioactive spills, releases, or leakages in two or more large operating areas.
+
- 3. Unusual Event or Alert caused by other emergency conditions, ;
such as fire, that may endanger human life or health as deemed necessary by Shift Supervision.
. PRECAUTIONS
- 1. Announcements should be clear and distinct.
- IMMEDIATE ACTIONS -
l 1.0 Emergency Director shall:
l 1 1.1 Designate the Administration Building or another practicable onsite locatign as the assembly area.
Assembly Area (s):
The Administration Building 1
IF THERE ARE NO APPROPRIATE ASSEMBLY AREAS WITHIN THE SECURITY BOUNDARY, CALL A SITE EVACUATION IN ACCORDANCE WITH EP-305 l
1.2 Notify the senior ranking security officer on shift that a plant evacuation is imminent, what assembly area (s) will be used, and to carry out emergency security procedures.
1.3 Announce a Part'ial Plant Evacuation over the station public address system as follows: (Announcements should be clear and distinct.)
THIS IS A PARTIAL PLANT EVACUATION. ALL PERSONNEL SHALL IMMEDIATELY EVACUATE THE (state plant evacuation areas) AND REPORT TO THE (state assembly areas).
ONSHIFT QPERATIONS PERSONNEL REPORT TO THE OPERATIONS SUPPORT n
9
)
EP-303 Page 3 -
Rev. 0
> WJK:lhd CENTER (or control room); EMERGENCY TEAMS REPORT TO THE ADMINISTRATION BUILDING; PERSONNEL SAFETY TEAM REPORT TO THE ASSEMBLY AREA'; ALL UNAFFECTED PERSONNEL REPORT TO OR REMAIN AT YOUR NORMAL DUTY STATION.
1.4 Repeat,'the message in Step 1.3. --
1.5 Direct activation of the evacuation sirens, in accordance with EP 301, Operating the Evacuation Sirens and the Pond Page System.
)
1.6 After the sirens have stopped, repeat the announcement in Step 1.3 of this procedure and the activation of the Evacuation Siren System.
l.7 Direct the evacuation of the Information Center in accordance with EP 306, Evacuation of the Information Center.
1.8 Contact appropriate group supervisors to verify accountability of individuals assigned to work in evacuated areas.
}
2.0 Affected Plant Personnel shall: -
, 2.1 Report directly to th'e assembly area.
2.2 Report to your supervisor that you are present and inform him
)
of any' persons that you know of'who are not present and why
~
they are not present (i.e., left work for some reason, is injured and you weren't able to transport them, etc.).
)
2.3 Separate themselves from the other plant personnel if they believe they are contaminated.
2.4 Stand by for further instructions.
, 3.0 Personnel Safety Team shall 3.1 Report to the assembly area and form groups to carry 3
out applicable portions of the following procedures as necessary.
i EP 207A Search and Rescue EP 207B Personnel Assembly and Accountability EP 207C First Aid
, EP 207D Personnel Monitoring and Decontamination i
)>
O
U
. EP-303 Page 4 -
Rev. 0 WJK:lhd j -
1 FOLLOW-UP ACTIONS 1.0 Emergency Director shall:
l 1.1 Direct supervisors to report any missing personnel to the .
Personnel Safety Team Leader. -- -
1.2 Direct the Personnel Safety Team Leader to list a'll unaccounted for personnel and send this list to the Control Room or the l
Technical Support Center, if activated.
1.3 Direct the Personnel Safety Team Leader to form Search and Rescue Groups, as necessary. ,
l.4 If the conditions relaxes, direct the personnel back to work.
If the situation degrades consider implementation of EP 305, Site Evacuation.
2.0 Personnel Safety Team Leader shall: ,
2.1 Send the list of unaccounted.for personnel to Shift Superintendent*
or the Technical Support Center (if activated).
2.2 Assemble Search and Rescue Group (s) from available personnel in accordance with EP 207A, Search and Rescue, as directed by the Emergency Director.
6 1
1 i
f
, EP-305 ccrE;LI.O /Jr^J:: . r- ! , Pr.ga 1
."' _ SV: 3 . . , _ _. Riv. O
-i , . _ . . . . _ ,
WJK:lhd ,
--xp Avt #,e PHILADELPHIA ELECTRIC COMPANY
- f. _ _
PEACH BOTTOM UNITS 2 AND 3 cn _ . ; EMERGENCY PLAN IMPLEMENTING PROCEDURE EP-305 SITE EVACUATIbN
- PURPOSE ,
To define the actions to be performed if a site evacuation.is required due to unexpected or uncontrolled hazards involving the main plant and extensive site areas outside the plant.
REFERENCES
- 1. Peach Bottom Atomic Power Station Emergency Plan Section Title 6.0 Emergency Measures
- 2. NUREG 0654 Criteria for Preparation $nd Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nucleat Poweg Plants.
- 3. EP 207A Search and Rescue -
- 4. EP 207B Personnel Assembly and Accountability
- 5. EP 207C First Aid -
- 6. EP 207D Personnel Monitoring and Decontamination
- 7. EP 301 Operating the Evacuation Alarm and Pond Page System
- 3. EP 305' Evacuation of the Information Center
- 89 305-1 Disposition of Evacuees
\
l
. . ~ ms EP-305 -
Page 2 Rev. 0 ,
WJK:lhd ACTIO.'I LEVEL
- 1. An unexpected or uncontrolled hazard exists which affects !
the main plant and.other areas of the site as indicated by Radiation Protection Team surveys, airborne or area radiation monitoring equipment as follows: ,
- a. Airborne radioactivity outside'the plant bui. within the i
-9 !
security fence greater than 1 x 10 uCi/cc for an l unidentified isotope in an occupational environment, j
- b. Radiation levels outside the plant but within the security fence greater than 10 mR/hr.
- 2. Partial Plant Ev'acuation conditions exist, as specified in EP 303 and:
- a. Radiation levels at the designated. partial plant evacuation assembly areas, are greater than 10 mR/hr or airborne
-10 contamination levels are~ greater than 4 x 10 uCi/cc for an unidentified isotope in a non-occupational environment. .
- 3. Roof vent radiation recorders indicate roof vent release rates in excess of the following levels:
One roof vent at Site Emergency Value Each roof vent at Alert valves CAUTION: IN-PLANT OR SITE RADIOLOGICAL HAZARDS MAY BE CAUSED BY RECIRCULATION OF ROOF VENT RELEASES.
PRECAUTIONS Mone I:llIEDIATE ACTIONS 1.0 Er.targency Director shall:
1.1 ' Determine which assembly area will be used. If the wind is from the north at greater than 3 miles per hour, designate the North Substation as the assembly area. Otherwise, designate the President's Utility Building (PUB). The alternate location is the Delta Service Building.
l e
EP-305 Page 3 Rev. 0 ,
WJK:lhd 1.2 Notify the senior ranking security officer on shift that a site evacuation is imminent and to carry out applicable emergency security procedures.
' ~
1.3 Announce a site evacuation over the station public ,
address system as follows: (Annoancements should be l
clear and distinct) __ .
THIS IS A SITE EVACUATION. ALL PERSONNEL EVACUATE TO I THE (state designated assembly area). ON-SHIFT OPERATIONS I
PERSONNEL REPORT TO THE OPERATIONS SUPPORT CENTER OR THE CONTROL ROOM; PERSONNEL SAFETY TEAM, REPORT TO THE ASSEMBLY AREA; OTHER EMERGENCY TEAMS REPORT ,
TO THE UNIT 1 AREA AND AWAIT FURTHER INSTRUCTIONS. -
1.4 Repeat the announcement.
1.5 Direct activation of'the evacuation sirens,. -
including the Pond Page System in accorda'nce with EP 301, Operating the Evacuation Sirens and Pond Page Systen.
1.6 After the sirens have stopped, repeat the announcement and the activation of the evacuation sirens and the Pond Page System. '
1.7 Direct the evacuation of the Information Center in accordance with EP 306, Evacuation of the Information Center.
1.8 Initiate accountability of personnel in accordance with EP 207B; Personnel. Assembly and Accountability.
2.0 Plant Personnel (except essential emergency team members)
~
t shall:
2.1 Evacuate the site and report to the assigned location in the assembly areas. If the area is inaccessible, you will be directed to an alternate assembly area.
3.0 Shift Personnel shall:
3.1 Report to the Operations Support Center or the control Room. -
4.0 Emergency Team Members chall:
4.1 Report to the Unit 1 Area and await further instructions.
e EP-305 Page 4 Rev. 0 ,
WJK:lhd 5.0 Security F'orce shall:
5.1 Direct the evacuation of people to the assembly. areas and carry out, emergency security procedures, and .
appropriate parts of EP 207B, Personnel Assembly and Accountability, as applicable.
6.0 Personnel Safety Team shall:
Report to the assembly area and form groups to carry
~
6.1 out applicable portions of the following procedures as necessary. '
EP 207A Search and Rescue EP 207B Personnel Assembly and Accountability EP 207C First Aid EP 207D Personnel Monitoring and Decontamination FOLLOW-UP ACTIONS 1.0 Emergency Director shall: ,
1.1 Direct the Personnel Safety Team Leader to fill out Appendix EP 305-1, Disposition of Evacuees, listing all ,
unaccounted'for personnel. .
2.0 Security Force shall:
2.1 Assist in evacuation of personnel.'
2.2 Collect security badges.
2.3 Carry out EP 207B, Personnel Assembly and Accountability, in conjunction with the Personnel '
Safety Team.
2.4 Control access to the plant per PP il.
3.0 Personnel Safety Team shall:
3 3.1 Report results of activities performed to the Personnel Safety Team Leader. ,
9
,-m-, e +r----w--,, w- - w w v .---- - - - rs -w v, - - - - -, . ,--~ - - . - -
e
. EP-305 i ,
Page 5 ;
) Rev. 0 ,
WJK:lhd
)
APPENDIX EP 305-1
) APPENDIX EP 305-1 DISPOSITION OF EVACUEES
, NEU
)
3 P.E. HARSHAW BADGE NO. EXP ,
1 2 .. .
NO. DISP. EMPL NAME OR ADDRESS CHE 1
2 .
3
?
4 5
6 i
7 8
9 ,
10
. 11 12 13 14 15 PREPARED BY DATE / / FORWARD TO tlOTES 1 DISPOSITION D-DETAINED 2 P.E. EMPLOYEE 3 ADURESS IF R-RELEASED CHECK IF YES NOT SITE EMPLOYEE O
-"rw- Ne ,w---wmm-s---- ,-rcm-wme w----y -w---,----w- -y '
l O
EP-306 ,
C0i;.n;]
.ui.1D].{-?7Q,C{?-
-. . .,5 I S : a. .
Re 0 WJK:lhd '
5: "' : , -
=- : OY
~
, dWMllfk Yff/
, PHILADELPHIA ELECTRIC COMPANY
-"1 PEACH BOTTOM UNITS 2 AND 3 C Ln -
EMERGENCY PLAN IMPLEMENTING PROCEDURE l EP-306 EVACUATION OF THE INFORMATION CENTER PURPOSE --
To define the actions to be performed in the event that the Information Center must be evacuated.
REFERENCES
- 1. Peach Bottom Atomic Power Station Emergency Plan Cgction Title 6.0 E:aergency Measures
- 2. NUREG 0654 Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear
, Power Plants. -
A'PPENDICES -
EP 306-1 Visitor's List ACTION LEVEL
- 1. The Information Center will be evacuated at the discretion of the Emergency Director.
- 2. A site evacuation is announced in accordance with EP 305.
PRECAUTIONS
- 1. If the Emergency Director informs the' Information' Center Staff that the wind is blowing DOWN-CHANNEL (WIND NORTH TO
~
l SOUTH), follow IMMEDIATE ACTIONS - PART-A. If the wind is bicuing UP-CHANNEL (WIND SOUTH TO NORTH), follow IMMEDIATP ACTIONS - PART-B. For CROSS WIND DIRECTION, use the discration of the Emergency Director. .
- 2. All efforts are to be made to keep the visitors calm.
- 3. No information relating to the emergency is to be divulged to the visitors.
. . man EP-306
. Page 2 Rev. 0 WJK:lhd '
Iifi!SDIA'2E ACTIONS - PART-A, WIND BLOWING DOWN-CHANNSL (WIND NORTH TO SOUTH)
, 1.0 Information Center Staff shall:
1 1.1 When directed by the Emergency Director, inform the visitors that the situation in the plant requires them -
to leave the Center and go to the Delta Service Building.
1.2 Inform the visitors that if they follow instructions there should be no problem.
1.3 Using a wall map, show the visitors the route to the Delta Service Building.
1.4 Make arrangements to get the visitors to the assembly area. Private vehicles will be used. '
1.5 Before exiting the Information Center, perform the following: -
1.5.1 Have the visitors provide their names and addresses on Appendix EP 306-1. ,
. 1.5.2- Frisk the visitors for contamination, if there '
is any contamination, record the level in Appendix EP 306-1.
1.6 Take the Information Center dosimetry badges and the frisker located in the Information Center to. the Delta Service Building. Lead the visitors to the Delta l Service Building.
FOLLOW-UP ACTIONS 1.0 Information Center Staff shall:
1.1 Escort the visitors into the Delta Service Building for
( shelter. Do not allow the visitors to wander off.
1.2 Limit their contact with other employees..
1.3 Assure the visitors that there is no problem, but that they must remain until they can be rechecked for contamination as a precautionary measure.
1.4 Record the visitor's names, address, and vehicle type / license number on Appendix EP 306-1, Visitor List.
1.5 Frisk the visitors again and their vehicles at the Delta Service Building.
y , -_ _ .. _ - _ _ _ _ . . _ _ _ _ _ . _ _ _ _
l EP-306 Page 3 Rev. O WJK:lhd 1.5 Inform the Personnel Safety Team Leader of any visitors who are injured or have evidence of radioactive contamination. The Personnel Safety Team Leader may be !
in the Emergency Operations Facility or the designated l Assembly Area'for plant personnel. Request a Personnel l
Safety Team member to be sent to the Delta Service l Building to direct decontamination activities, if * '
necessary. ~
)
1.7 Allow people that have been frisked and are documented ,
as " clean" to leave the area.
1.8 Forward the Information Center Dosimetry Badges to the '
Personnel Safety Team Leader for processing. .
l IMMEDIATE ACTIONS - PART-B, WIND BLOWING UP-CHANNEL (WIND SOUTH TO NORTH) 1.0 Information Center Staff shall:
1.1 When directed by the Emergency Director, inform the visitors that the situation in the plant requires them to stay in the Information Center until such time that the area is deemed safe for them to leave the premises.
1.2 Before exiting the Information Center, perform the following:
a) Have the visitors provide their names and addresses on Appendix EP 306-1.
b) Frisk the visitors for contamination, if there is any contamination, record the level in Appendix EP 306-1 and direct the contaminated person to wash the affected area in the Information Center washroom, instruct the person NOT to use water warmer than body temperatTre.
.3 Request a Personnel Safety Team member to come co the Information Center if contamination is found.
1.4 Frisk the visitor's vehicles for contamination after frisking the visitors and when the outside atmosphere is deemed safe by a Personnel Safety Team Member or by direction of the Emer3ency Director.
4 e
s EP-306 *
. Page 4 Rev. O WJK:1hd '
FCLLO!!-UP ACTIONS 1.0 Information Center Staff shall:
1.1 Allow the visitors to vacate the Information Center"and exit the alte via the Unit 1 access road when. directed to do so by the Emergency Director.
- 1.2 Send the Information Center dosimetry badges to the Personnel Safety Team Leader for processing. The Personnel Safety Team Leader may be in the Emergency Operations Facility or the designated Assembly Area for plant personnel.
m 4
9 9
e *
- 4 O
~
un EP-306
, Page 5 Rev. O WJK:lhd '
APPENDIX EP 306-1 VISITOR'S LIST VEHICLE LICENSE Ct NAME ADDRESS TYPE NUMBER P1 1 .
2 3
4 '
. 5 6
7 .
8 9
10 P - Personnel Contamination SIGNATURE-INFORMATION i
CENTER STAFP MEMBER V - Vehicular Contamination DATE 9
9 I