Proposed Tech Specs,Sr 3.3.1.1.12,for APRM Flow Biased High Scram Function,Allowing SR to Be Performed W/O Entering Associated Conditions & Required Actions for Up to Six H Provided Core Flow at or Above 82%
ML20117M704
Person / Time
Site: Peach Bottom 
Issue date: 06/13/1996
From:
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
Shared Package
ML20117M699 List:
References
NUDOCS 9606180722
Download: ML20117M704 (4)


Text

-.

J l

t i

ATTACHMENT 2 PEACH BOTTOM ATOMIC POWER STATION UNIT 2 4

Docket No. 50-277 1

License No. DPR-44 Facility Operating Ucense Change Request l

ECR 96-02011 1

"APRM Flow Biased High Scram Surveillance Requirement 3.3.1.1.12" l

i List of Revised Pages 3.3-5 i

J B 3.3-33 4

n 1-9606100722 960613 PDR ADOCK 05000277 P

PDR.

RPS Instrumentation 3.3.1.1 SURVEILLANCE REOUIREMENTS (continued)

SURVEILLANCE FREQUENCY SR 3.3.1.1.9 Perfom CHANNEL FUNCTIONAL TEST.

92 days SR 3.3.1.1.10


NOTE-------------------

Radiation detectors are excluded.

Perform CHANNEL CALIBRATION.

92 days SR 3.3.1.1.11


NOTES------------------

Neutron detecto's are excluded.

j 1.

r 2.

Not required to be performed when entering MODE 2 from MODE 1 until 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after entering MODE 2.

Perform CHANNEL CALIBRATION.

184 days SR 3.3.1.1.12


NOTES------------------

1.

Neutron detectors are excluded.

2.

For Function 2.a, not required to be performed when entering N0DE 2 from MODE 1 until 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after entering 4... MODE 2.

Perform CHANNEL CALIBRATION.

18 months SR 3.3.1.1.13 Verify Turbine Stop Valve-Closure and 24 months Turbine Control Valve Fast Closure, Trip 011 Pressure-Low Functions are not bypassed when THERMAL POWER is 2: 30% RTP.

3, ne &

+ ten 2. f, us,]

ccyledson o(

e l es<

ye M

eb cle b el h" vP h ave.ptav i.s n,4,pe.r{f A1e han s msy C o.s els h e.us << 8 af he le in l0 << Moc o a f ee g

\\

uF ~.ibwe 92LW<>e 4 e n. pw de<

,w PBAPS UNIT 2 3.3-5 Amendment No. 210 CxCvf on N.i u " w e fla n c t- }?epaire,.,f ive h 2, b

.O ' ' N..,... _

v A

RPS Instrumentation

(

B 3.3.1.1

)

i BASES l

SURVEILLANCE SR 3.3.1.1.10. SR 3.3.1.1.11. SR 3.3.1.1.12.

REQUIREMENTS SR 3.3.1.1.15. and SR 3.3.1.1.1%

(continued)

L

}

calibrations, consistent with the current plant specific setpoint methodology. SR 3.3.1.1.16, however, is only a i

calibration of the radiation detectors using a standard j

i radiation source, j

4 j

As noted for SR 3.3.1.1.11 and SR 3.3.1.1.12, neutron detectors are excluded from CHANNEL CALIBRATION because they are passive devices, with minimal drift, and because of the difficulty of simulating a meaningful signal. Changes.in l

neutron detector sensitivity are compensated for by T

performing the 7 day calorimetric calibration (SR 3.3.1.1.2) and the 1000 MWD /T LPRM calibration against the TIPS (SR 3.3.1.1.8).

A second note is provided for SRs 3.3.1.1.11 and 3.3.1.1.12 that allows the APRM and IRM SRs to be performed within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> of entering MODE 2.from i

MODE 1.

Testing of the MODE 2 APRM and IRM Functions cannot be performed in MODE 1 without utilizing jumpers, lifted i

leads or movable links. This Note allows entry into MODE 2 from MODE 1, if the 184 day or 18 month Frequency is not met i

l

)

per SR 3.0.2.

Twelve hours is based on operating experience and in consideration of providing a reasonable time in which

/ [p to_ complete _the_SR.A.As noted for SR 3.3.1.1.10, radiation detectors are excluded from CHANNEL CALIBRATION due to ALARA j

l reasons (when the plant is operating, the radiation detectors are generally in a high radiation area; the steam tunnel). This exclusion is acceptable because the radiation 4

l detectors are passive devices, with minimal drift. The i

radiation detectors are calibrated in accordance with SR 3.3.1.1.16 on a 24 month Frequency.

)

i j

The 92 day Frequency of SR 3.3.1.1.10 is conservative with respect to the magnitude of equipment drift assumed in the i

setpoint analysis. The Frequencies of SR 3.3.1.1.11 and j

SR 3.3.1.1.12 are based upon the assumption of a 184 day or

~

an 18 month calibration interval, respectively, in the i

determination of the magnitude of equipment drift in the setpoint analysis. The Frequencies,of SR 3.3.1.1.15 and SR 3.3.1.1.16 are based upon the assumption of a 24 month calibration interval in the determination of the magnitude of equipment drift in the applicable setpoint analysis.

(continued) i i

PBAPS UNIT 2 B 3.3-33 Revision No. 1 J

!