December 16, 2019 MEMORANDUM TO:
Victor E. Hall, Chief Vogtle Project Office Office of Nuclear Reactor Regulation FROM:
Jennivine Rankin, Project Manager /RA/
Vogtle Project Office Office of Nuclear Reactor Regulation
SUBJECT:
AUDIT REPORT FOR VOGTLE ELECTRIC GENERATING PLANT UNIT 4, REQUEST FOR LICENSE AMENDMENT:
REINFORCEMENT CHANGES FOR WALL L AND WALL 7.3 (LAR-19-016R1)
By letter dated August 22, 2019 (Agencywide Documents Access and Management System (ADAMS) Accession Number ML19234A327), Southern Nuclear Operating Company (SNC or licensee) requested an amendment to Combined License (COL) Number NPF-92, for Vogtle Electric Generating Plant (VEGP) Unit 4. The amendment proposed to depart from AP1000 Design Control Document (DCD) Tier 2* material that has been incorporated into the Updated Final Safety Analysis Report (UFSAR). The proposed departure consists of changes to Tier 2* information in the UFSAR to change the provided area of horizontal reinforcement for VEGP Unit 4 Wall L and Wall 7.3 from elevation 117'-6" to 135'-3". The NRC issued an audit summary dated October 11, 2019 (ADAMS Accession No. ML19280D872) to document the audit regarding the proposed horizontal reinforcement. Subsequently, by letter dated October 25, 2019, SNC revised its request in LAR-19-016R1 (ADAMS Accession No. ML19298D420), to change the provided area of vertical reinforcement for VEGP Unit 4 Wall L from elevation 117'-6" to 135'-3" in addition to the previously submitted horizontal reinforcement changes.
CONTACT: Jennivine Rankin, NRR/VPO 301-415-1530
Staff from the Structural, Civil, Geotech Engineering Branches (NRR/DEX/ESEA and NRR/DEX/ESEB) conducted an audit from September 9 to November 26, 2019, via the Westinghouse Electric Companys electronic reading room. The purpose of the audit was to gain a better understanding of the licensees proposed changes by examining relevant documented evidence that supports reaching a conclusion of reasonable assurance and reviewing related documentation and non-docketed information to compliance with applicable regulations.
Docket No.: 52-026
Enclosure:
Regulatory Audit Report cc: See next page
- via email NRO-008 OFFICE NRR/VPO/PM NRR/VPO/LA NRR/DEX/ESEA/BC (A) NRR/VPO/BC NAME JRankin RButler DWilliams*
VHall DATE 12/9/19 12/6/19 12/10/19 12/16/19
Vogtle Units 3 & 4 Mailing List (Revised 08/16/2018) cc:
Office of the Attorney General Resident Inspector 40 Capitol Square, SW Vogtle Plant Units 3 & 4 Atlanta, GA 30334 8805 River Road Waynesboro, GA 30830 Resident Manager Oglethorpe Power Corporation Mr. Barty Simonton Alvin W. Vogtle Nuclear Plant Team Leader 7821 River Road Environmental Radiation Program Waynesboro, GA 30830 Air Protection Branch Environmental Protection Division Southern Nuclear Operating Company, Inc.
4244 International Parkway, Suite 120 Document Control Coordinator Bin N-226-EC Atlanta, GA 30354-3906 3535 Colonnade Parkway Birmingham, AL 35243 George B. Taylor, Jr.
2100 East Exchange Pl Anne F. Appleby Atlanta, GA 30084-5336 Olgethorpe Power Corporation 2100 East Exchange Place Brian H. Whitley Tucker, GA 30084 3535 Colonnade Parkway, Bin N-226-EC 42 Inverness Center Parkway, BIN B237 County Commissioner Birmingham, AL 35243 Office of the County Commissioner Burke County Commission Mr. Michael Yox Waynesboro, GA 30830 Site Regulatory Affairs Director Vogtle Units 3 & 4 Mr. Wayne Guilfoyle 7825 River Road, Bin 63031 Commissioner District 8 Waynesboro, GA 30830 Augusta-Richmond County Commission 4940 Windsor Spring Rd Hephzibah, GA 30815 Gwendolyn Jackson Burke County Library 130 Highway 24 South Waynesboro, GA 30830 Mr. Reece McAlister Executive Secretary Georgia Public Service Commission Atlanta, GA 30334 Page 1 of 3
Vogtle Units 3 & 4 Mailing List Email acchambe@southernco.com (Amy Chamberlian) agaughtm@southernco.com (Amy Aughtman)
ALPUGH@southernco.com (Amanda Pugh) awc@nei.org (Anne W. Cottingham) becky@georgiawand.org (Becky Rafter) bhwhitley@southernco.com (Brian Whitley)
Bill.Jacobs@gdsassociates.com (Bill Jacobs) bjadams@southernco.com (Brad Adams) bwwaites@southernco.com (Brandon Waites) castelca@westinghouse.com (Curtis Castell) comerj@westinghouse.com (James Comer) crpierce@southernco.com (C.R. Pierce) dahjones@southernco.com (David Jones) david.hinds@ge.com (David Hinds) david.lewis@pillsburylaw.com (David Lewis) dgbost@southernco.com (Danny Bost) dlfulton@southernco.com (Dale Fulton) drculver@southernco.com (Randy Culver) durhamdc@westinghouse.com (David Durham) ed.burns@earthlink.net (Ed Burns) edavis@pegasusgroup.us (Ed David) erg-xl@cox.net (Eddie R. Grant) fdhundle@southernco.com (Forrest Hundley) fhwillis@southernco.com (Fred Willis)
G2NDRMDC@southernco.com (SNC Document Control) graysw@westinghouse.com (Scott W. Gray) jadwilli@southernco.com (J.D. Williams) james1.beard@ge.com (James Beard) jannina.blanco@pillsburylaw.com (Jannina Blanco) jantol1dj@westinghouse.com (David Jantosik) jenmorri@southernco.com (Jennifer Buettner)
JHaswell@southernco.com (Jeremiah Haswell) jim@ncwarn.org (Jim Warren)
John.Bozga@nrc.gov (John Bozga)
Joseph_Hegner@dom.com (Joseph Hegner) jpredd@southernco.com (Jason R. Redd) jranalli@meagpower.org (Jerry Ranalli) karen.patterson@ttnus.com (Karen Patterson) karlg@att.net (Karl Gross) kmstacy@southernco.com (Kara Stacy)
KSutton@morganlewis.com (Kathryn M. Sutton) kwaugh@impact-net.org (Kenneth O. Waugh) markus.popa@hq.doe.gov (Markus Popa)
Page 2 of 3
Vogtle Units 3 & 4 Mailing List Matthew.Williams@hq.doe.gov (Matthew Williams) mdmeier@southernco.com (Mike Meier) media@nei.org (Scott Peterson)
Melissa.Smith@Hq.Doe.Gov (Melissa Smith)
Michael.Kuca@hq.doe.gov (Michael Kuca) mike.price@opc.com (M.W. Price)
MKWASHIN@southernco.com (MKWashington) mlgraves@southernco.com (Michelle Graves)
MSF@nei.org (Marvin Fertel) myox@southernco.com (Mike Yox) nirsnet@nirs.org (Michael Mariotte)
Nuclaw@mindspring.com (Robert Temple) patriciaL.campbell@ge.com (Patricia L. Campbell)
Paul@beyondnuclear.org (Paul Gunter) pbessette@morganlewis.com (Paul Bessette) r.joshi15@comcast.net (Ravi Joshi)
RJB@NEI.org (Russell Bell)
Ronald.Jones@scana.com (Ronald Jones) rwink@ameren.com (Roger Wink) sabinski@suddenlink.net (Steve A. Bennett) sara@cleanenergy.org (Sara Barczak) sblanton@balch.com (Stanford Blanton)
Shiva.Granmayeh@hq.doe.gov (Shiva Granmayeh) sjackson@meagpower.org (Steven Jackson) skauffman@mpr.com (Storm Kauffman) sroetger@psc.state.ga.us (Steve Roetger) stephan.moen@ge.com (Stephan Moen) stephen.burdick@morganlewis.com (Stephen Burdick) tom.miller@hq.doe.gov (Tom Miller)
TomClements329@cs.com (Tom Clements)
Vanessa.quinn@dhs.gov (Vanessa Quinn) vcsummer2n3@gmail.com (Brian McIntyre) wasparkm@southernco.com (Wesley A. Sparkman) wayne.marquino@gmail.com (Wayne Marquino) weave1dw@westinghouse.com (Doug Weaver) x2gabeck@southernco.com (Gary Becker) x2kmseib@southernco.com (Kristin Seibert)
Page 3 of 3
4 Report of Regulatory Audit License Amendment Related to Reinforcement Changes for Wall L and Wall 7.3 Vogtle Electric Generating Plant, Unit 4 (LAR 19-016R1)
A.
Background
By letter dated August 22, 2019 (Agencywide Documents Access and Management System (ADAMS) Accession Number ML19234A327), Southern Nuclear Operating Company (SNC or licensee) requested an amendment to Combined License (COL) Number NPF-92, for Vogtle Electric Generating Plant (VEGP) Unit 4. The amendment proposed to depart from AP1000 Design Control Document (DCD) Tier 2* material that has been incorporated into the Updated Final Safety Analysis Report (UFSAR). The proposed departure consists of changes to Tier 2*
information in the UFSAR to change the provided area of horizontal reinforcement for VEGP Unit 4 Wall L and Wall 7.3 from elevation 117'-6" to 135'-3". The NRC issued an audit summary dated October 11, 2019 (ADAMS Accession No. ML19280D872) to document the audit regarding the proposed horizontal reinforcement. Subsequently, by letter dated October 25, 2019, SNC revised its request in LAR-19-016R1 (ADAMS Accession No. ML19298D420), to change the provided area of vertical reinforcement for VEGP Unit 4 Wall L from elevation 117'-6" to 135'-3" in addition to the previously submitted horizontal reinforcement changes.
The purpose of this audit is to gain a better understanding of the calculations associated with LAR 19-016.
B.
Bases This regulatory audit is based on the following:
VEGP Units 3 and 4 UFSAR Revision 8, Chapter 3, Design of Structures, Components, Equipment and Systems, Appendix 3H, Auxiliary and Shield Building Critical Sections (ADAMS Accession No. ML19171A061).
The audit plan is available in ADAMS under Accession No. ML19248C020.
C.
Logistics Date: September 9, 2019 - December 2, 2019 Location: The audit was conducted through the Westinghouse Electric Companys electronic reading room.
D.
Audit Team Members The following U.S. Nuclear Regulatory Commission (NRC) staff members participated in substantive discussions during the audit:
Pravin Patel, Structural Engineer, Technical Reviewer Maryam Khan, Structural Engineer, Technical Reviewer Jennivine Rankin, Project Manager
5 E.
Applicant and Industry Staff Participants Mark Humphrey (SNC)
F.
Documents Audited SV4-CR01-GNR-000583, U4 Walls 7.3 & L (EL 117'-6" to 135'-3") Reinf. w/o a Splice (ESR 50026080 & 50026081), Revision 0.
SV4-CR01-GNR-000610, Wall L Vertical Dowels Missing at EL 117'-6" to 135'-3" (ESR 500030817), Revision 0.
G.
Description of Audit Activities and Summary of Observations The NRC staff examined documentation supporting LAR-19-016. Specifically, the staff examined the nonconformance and disposition reports as noted in Section F above associated with the non-conformances and deviations for Walls 7.3 and L. The reports provided the evaluation used to determine the revised minimum provided area of steel in the walls and justified the acceptability of the revised value as compared to the reinforcement values required listed in UFSAR Tables 3H.5-5 and 3H.5-7. Based on the staffs evaluation, the staff noted that SNCs evaluation of the as-built reinforcement area as compared to the design requirements are reasonable.
H.
Exit Briefing The staffs audit exit briefing was conducted on November 26, 2019. The staff indicated there were currently no additional information needed for the review.
I.
Requests for Additional Information (RAI) Resulting from Audit No RAIs were issued because of this audit.
J.
Open Items and Proposed Closure Paths There were no open items from the audit.
K.
Deviations from the Audit Plan The audit was extended from September 25, 2019 to December 2, 2019, to allow staff additional time to examine the documents regarding horizontal and vertical reinforcement changes.